Zhang Y, Liu H, Zhou L, Yang J, Liu W, Yang S, Huang X. Effect of electromagnetic middle-ear implant simulating sites on the stapes spatial motion: A finite element analysis. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024:e3871. [PMID: 39295320 DOI: 10.1002/cnm.3871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 05/07/2024] [Accepted: 09/01/2024] [Indexed: 09/21/2024]
Abstract
The electromagnetic middle-ear implant (MEI) is a new type of hearing device for addressing sensorineural and mixed hearing loss. The hearing compensation effect of the MEI varies depending on the transducer stimulation sites. This paper investigates the impact of transducer stimulation sites on MEI performance by analyzing stapes spatial motion. Firstly, we constructed a human-ear finite element model based on micro-CT scanning and inverse molding techniques. This model was validated by comparing its predictions of stapes spatial motion and cochlear response with experimental data. Then, stimulation force was applied at four common sites: umbo, incus body, incus long process and stapes to simulate the electromagnetic transducer. Results show that at low and middle frequencies, stapes-stimulating and incus-long-process-stimulating produce similar spatial motion to normal hearing; at high frequencies, incus-body-stimulating produces similar results to normal hearing. The equivalent sound pressure level generated by the stapes piston motion is less sensitive to the stimulation direction than that deduced by the stapes rocking motion.
Collapse
Affiliation(s)
- Yixiang Zhang
- School of Mechatronic Engineering, China University of Mining and Technology, Xuzhou, China
| | - Houguang Liu
- School of Mechatronic Engineering, China University of Mining and Technology, Xuzhou, China
| | - Lei Zhou
- Department of Otorhinolaryngology-Head and Neck Surgery, Zhongshan Hospital affiliated to Fudan University, Shanghai, China
| | - Jianhua Yang
- School of Mechatronic Engineering, China University of Mining and Technology, Xuzhou, China
| | - Wen Liu
- Department of Otolaryngology, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
- Artificial Auditory Laboratory of Jiangsu Province, Xuzhou Medical University, Xuzhou, China
| | - Shanguo Yang
- School of Mechatronic Engineering, China University of Mining and Technology, Xuzhou, China
| | - Xinsheng Huang
- Department of Otorhinolaryngology-Head and Neck Surgery, Zhongshan Hospital affiliated to Fudan University, Shanghai, China
| |
Collapse
|
2
|
Gantner S, Epp A, Pollotzek M, Hempel JM. Long-term results and quality of life after vibrant soundbridge implantation (VSBs) in children and adults with aural atresia. Eur Arch Otorhinolaryngol 2024; 281:129-139. [PMID: 37603051 PMCID: PMC10764446 DOI: 10.1007/s00405-023-08100-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 06/28/2023] [Indexed: 08/22/2023]
Abstract
PURPOSE The aim of this study was to evaluate the long-term effectiveness and acceptance of the active middle ear implant system Vibrant Soundbridge (VSB®, MED-EL, Austria) in patients with aural atresia or aplasia (children and adults). METHODS Data from 51 patients (mean age 13.9 ± 11.3 years), 42 (79.2%) children and adolescents, and 11 (20.8%) adults) who received a VSB implant between 2009 and 2019 at the Department of Otolaryngology at LMU Clinic Großhadern, Munich were included in the study. Pure-tone audiometry, speech recognition in a quiet environment and in a noisy environment were performed preoperatively, during the first fitting of the audio processor, after 1-3 years, after 3-5 years, and after 5 years (if possible). The follow-up period ranged from 11 to 157 months with a mean of 58.6 months (4.8 years). Furthermore, the benefit of the VSB was evaluated by self-assessment questionnaires (Speech, Spatial, and Qualities of Hearing Scale, respectively, for parents). RESULTS Significant improvements were observed in hearing and speech comprehension immediately after the initial fitting of the VSB system (mean hearing gain 38.4 ± 9.4 dB HL) and at follow-up intervals (1-3, 3-5 and after 5 years) for children and adults (p < 0.01). The values remained stable over the long-term, indicating a sustained functional gain from the VSB (mean hearing gain 38.9 ± 9.2 dB HL). The results of the self-assessments affirm the positive influence on hearing and speech comprehension with the VSB. With the VSB, there was an improvement of 41.3 ± 13.7% in the Freiburg monosyllable test. CONCLUSION These results (a stable hearing gain over the long term, a good tolerance of the implant and an improvement in quality of life) affirm the recommendation for using the active middle ear implant VSB as early as permitted for aural atresia and aplasia patients. This study represents the audiometric results with the (to date) largest collective of aural atresia patients and with a long follow-up period.
Collapse
Affiliation(s)
- Sophia Gantner
- Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig Maximilian University Munich, Munich, Germany.
| | - Alexandra Epp
- Paediatric Hospital, University Hospital, Augsburg, Germany
| | - Marlene Pollotzek
- Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig Maximilian University Munich, Munich, Germany
| | - John Martin Hempel
- Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig Maximilian University Munich, Munich, Germany
| |
Collapse
|
3
|
Hundertpfund J, Dejaco T, Meyer JE, Óvári A. Round-Window Vibroplasty: Systematic Review and Meta-Analysis of Audiological Effectiveness With Different Round-Window Coupling Techniques. Otol Neurotol 2023; 44:e549-e559. [PMID: 37504977 DOI: 10.1097/mao.0000000000003958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/29/2023]
Abstract
OBJECTIVE Active middle ear implants can be directly coupled to the round-window (RW) membrane via RW Vibroplasty. The objectives of this systematic review were to summarize data on different RW coupling techniques and to investigate their effect on audiological and safety outcomes using meta-analyses. DATABASES REVIEWED PubMed (MEDLINE), Cochrane Library, and Embase (DIMDI). METHODS All publications reporting on audiological outcomes in human patients after RW Vibroplasty were included. Two independent reviewers carried out screening and data extraction. Meta-analyses and meta-regression were used to evaluate the potential effects of surgical and demographic parameters on primary audiological outcomes. Adverse events were extracted and tabulated for qualitative analysis. RESULTS Fourteen different combinations of surgical coupling parameters were identified in 61 included publications. Overall, data from 23 publications could be used for meta-analyses. Significantly better aided sound-field thresholds were reported for RW Vibroplasty performed without a dedicated coupler and using fascia as interponate, compared with RW Vibroplasty with an RW coupler or without an interponate. These effects were not found in other outcomes (i.e., functional gain, word recognition score). Reporting of adverse events was relatively heterogeneous, with 32 explicit mentions of revision surgery after the loss of coupling efficacy. CONCLUSION There are numerous publications investigating the effectiveness of coupling active middle ear implants to the RW membrane. However, studies are typically undersampled and of low evidence level. Using meta-analyses, weighted means, and qualitative analyses enabled a summary of the existing literature on audiological and safety outcomes after RW Vibroplasty. Individual selection of the most appropriate coupling modality with standardized intraoperative measurement and careful patient follow-up may be considered key factors for achieving effective RW coupling.
Collapse
|
4
|
Seiwerth I, Plößl S, Herzog M, Schilde S, Radetzki F, Krämer S, Rahne T, Plontke SK. Individual computer-assisted 3D planning for placement of auricular prosthesis anchors in combination with an implantable transcutaneous bone conduction hearing device in patients with aural atresia. HNO 2023; 71:1-9. [PMID: 36083471 PMCID: PMC10409664 DOI: 10.1007/s00106-022-01190-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/12/2022] [Indexed: 11/04/2022]
Abstract
BACKGROUND The simultaneous implantation of the Bonebridge (MED-EL, Innsbruck, Austria), a semi-implantable active transcutaneous bone conduction hearing device and anchors for auricular prostheses can be challenging as both implants contain magnets and compete for the narrow space in the designated implantation area. MATERIAL AND METHODS A preoperative planning tool (virtual surgery) was used with individual 3D computer models of the skull and implants for finding optimal implant positions for both the floating mass transducer (FMT) and the anchors for the auricular prosthesis. The interaction between the magnetic prosthesis anchors and the FMT was measured by means of static magnetic forces. A retrospective data analysis was conducted to evaluate the surgical and audiological outcome. RESULTS Between 2014 and 2021, a 3D planning of a simultaneous implantation of the Bonebridge with auricular prosthesis anchors was conducted on 6 ears of 5 patients (3 males, 2 females; age range 17-56 years). The individual preoperative planning was considered very useful for the optimal placement of bone anchors in combination with the Bonebridge. Audiological data showed a clear benefit for hearing 3 months and > 11 months after implantation. No adverse interactions between the magnetic prosthesis anchors and the FMT were observed. In two patients, revision surgery was carried out due to skin inflammation or wound healing problems. No long-term complications were observed 3-5 years after surgery. CONCLUSION Preoperative 3D planning represents a clear benefit for the simultaneous audiological and esthetic rehabilitation using the Bonebridge and anchors for auricular prostheses.
Collapse
Affiliation(s)
- Ingmar Seiwerth
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medicine Halle (Saale), Martin Luther University Halle-Wittenberg, Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany
| | - Sebastian Plößl
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medicine Halle (Saale), Martin Luther University Halle-Wittenberg, Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany
- Department of Otorhinolaryngology, Head and Neck Surgery, Martha-Maria Hospital Halle-Dölau, Halle (Saale), Germany
| | - Michael Herzog
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medicine Halle (Saale), Martin Luther University Halle-Wittenberg, Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany
- Department of Otorhinolaryngology, Carl Thiem Klinikum, Cottbus, Germany
| | - Sebastian Schilde
- Department of Orthopedic and Trauma Surgery, University Medicine Halle (Saale), Martin Luther University Halle-Wittenberg, Halle (Saale), Germany
| | - Florian Radetzki
- Department of Orthopedic and Trauma Surgery, University Medicine Halle (Saale), Martin Luther University Halle-Wittenberg, Halle (Saale), Germany
- Department of Orthopedic und Trauma Surgery, Brandenburg Medical School Theodor Fontane, Klinikum Dessau, Dessau, Germany
| | | | - Torsten Rahne
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medicine Halle (Saale), Martin Luther University Halle-Wittenberg, Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany
| | - Stefan K Plontke
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medicine Halle (Saale), Martin Luther University Halle-Wittenberg, Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany.
| |
Collapse
|
5
|
Tollin DJ, Koka K, Peacock J. Using Stapes Velocity to Estimate the Efficacy of Mechanical Stimulation of the Round Window With an Active Middle Ear Implant. Otol Neurotol 2023; 44:e311-e318. [PMID: 36962010 PMCID: PMC10175173 DOI: 10.1097/mao.0000000000003859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2023]
Abstract
OBJECTIVE To test a method to measure the efficacy of active middle ear implants when coupled to the round window. METHODS Data previously published in Koka et al. ( Hear Res 2010;263:128-137) were used in this study. Simultaneous measurements of cochlear microphonics (CM) and stapes velocity in response to both acoustic stimulation (forward direction) and round window (RW) stimulation (reverse direction) with an active middle ear implant (AMEI) were made in seven ears in five chinchillas. For each stimulus frequency, the amplitude of the CM was measured separately as a function of intensity (dB SPL or dB mV). Equivalent vibrational input to the cochlea was determined by equating the acoustic and AMEI-generated CM amplitudes for a given intensity. In the condition of equivalent CM amplitude between acoustic and RW stimulation-generated output, we assume that the same vibrational input to the cochlea was present regardless of the route of stimulation. RESULTS The measured stapes velocities for equivalent CM output from the two types of input were not significantly different for low and medium frequencies (0.25-4 kHz); however, the velocities for AMEI-RW drive were significantly lower for higher frequencies (4-14 kHz). Thus, for RM stimulation with an AMEI, stapes velocities can underestimate the mechanical input to the cochlea by ~20 dB for frequencies greater than ~4 kHz. CONCLUSIONS This study confirms that stapes velocity (with the assumption of equivalent stapes velocity for forward and reverse stimulation) cannot be used as a proxy for effective input to the cochlea when it is stimulated in the reverse direction. Future research on application of intraoperative electrophysiological measurements during surgery (CM, compound action potential, or auditory brainstem response) for estimating efficacy and optimizing device coupling and performance is warranted.
Collapse
Affiliation(s)
- Daniel J. Tollin
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, CO 80045
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, CO 80045
| | - Kanthaiah Koka
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, CO 80045
| | - John Peacock
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, CO 80045
| |
Collapse
|
6
|
Influence of the Coupling on the Hearing Outcome After Implantation of an Active Middle Ear Implant: Comparison of the Transmission Behavior in Temporal Bone Experiments With Clinical Data. Ear Hear 2023; 44:135-145. [PMID: 35913925 DOI: 10.1097/aud.0000000000001258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVES The active middle ear implant, Vibrant Soundbridge (VSB), can be implanted with a variety of couplers. Hearing outcome after implantation has been investigated in both temporal bone (TB) experiments and patient studies, but the relationship between experimental and clinical data is still weak in the literature. Therefore, experimental data from TB experiments should be compared with patient data in a retrospective study, in which the floating mass transducer is used with couplers of the third generation. Actuator coupling structures included the long (LP coupler) and short (SP coupler) incus process, the stapes head (Clip coupler), and the round window membrane (RW soft coupler). METHODS In the TB experiments, the sound transmission after vibroplasty on the above-mentioned actuator coupling structures was determined in 32 specimens by means of laser Doppler vibrometry on the stapes footplate. Data of 69 patients were analyzed. The main target audiometric parameters were the postoperative aided word recognition score (WRS) in the free field at 65 dB SPL (WRS 65 dB in %), the preoperative and postoperative pure-tone average (PTA4, including the frequencies 0.5, 1, 2, and 4 kHz) of the bone conduction hearing threshold (PTA4BC), the aided postoperative air conduction hearing threshold in the free field (PTA4FF) and the direct threshold (Vibrogram) at least 6 months postoperatively. The coupling efficiency of the actuator (Vibrogram-PTA4BC) as well as the effective hearing gain (PTA4FF-PTA4BC) was compared between the couplers. RESULTS The analysis in the main speech range (0.5-4 kHz) indicated that in the TB experiments, the LP coupler tends to have the best coupling quality at low frequencies (500-1000 Hz). This was up to 15 dB above the worst actuator (RW soft coupler). However, the results missed the significance level ( p > 0.05). In the high frequencies (2000-4000 Hz), the Clip coupler showed the best coupling quality. This was 15 dB above the worst actuator (SP coupler). However, the results missed the significance level ( p > 0.05), too. The postoperative WRS at 65 dB SPL and the postoperative PTA4FF were independent of the actuator coupling structure. The PTA4BC was stable at 6 months postoperatively. For the PTA4 of the coupling efficiency, there were no significant differences between the actuator coupling structures (LP 8.9 dB ± 12.9; SP 9.5 ± 6.5 dB; Clip 5.2 ± 10.5 dB; RW 12.7 ± 11.0 dB). However, the tendential inferiority of the RW soft coupler with regard to transmission in the low-frequency range and the tendential superiority of the Clip coupler in the high-frequency range that have already been displayed experimentally could be confirmed in the clinical results. However, the clinical results missed the significance level, too ( p > 0.05). CONCLUSIONS In vivo, there are no significant differences in the postoperative outcome stratified according to coupling the target structure. The differences known from the experimental setting were repressed by individual biasing factors. However, to ensure sufficient postoperative speech intelligibility, the frequency-specific transmission behavior of the couplers should be taken into account when setting the indication for VSB implantation.
Collapse
|
7
|
[Individual computer-assisted 3D planning for placement of auricular prosthesis anchors in combination with an implantable transcutaneous bone conduction hearing device in patients with aural atresia. German version]. HNO 2022:10.1007/s00106-022-01189-3. [PMID: 35920881 DOI: 10.1007/s00106-022-01189-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/12/2022] [Indexed: 11/04/2022]
Abstract
BACKGROUND The simultaneous implantation of the Bonebridge (MED-EL, Innsbruck, Austria), a semi-implantable active transcutaneous bone conduction hearing device and anchors for auricular prostheses can be challenging as both implants contain magnets and compete for the narrow space in the designated implantation area. MATERIAL AND METHODS A preoperative planning tool (virtual surgery) was used with individual 3D computer models of the skull and implants for finding optimal implant positions for both the floating mass transducer (FMT) and the anchors for the auricular prosthesis. The interaction between the magnetic prosthesis anchors and the FMT was measured by means of static magnetic forces. A retrospective data analysis was conducted to evaluate the surgical and audiological outcome. RESULTS Between 2014 and 2021 a 3D planning of a simultaneous implantation of the Bonebridge with auricular prosthesis anchors was conducted on 6 ears of 5 patients (3 males, 2 females; age range 17-56 years). The individual preoperative planning was considered very useful for the optimal placement of bone anchors in combination with the Bonebridge. Audiological data showed a clear benefit for hearing 3 months and > 11 months after implantation. No adverse interactions between the magnetic prosthesis anchors and the FMT were observed. In two patients, revision surgery was carried out due to skin inflammation or wound healing problems. No long-term complications were observed 3-5 years after surgery. CONCLUSION Preoperative 3D planning represents a clear benefit for the simultaneous audiological and esthetic rehabilitation using the Bonebridge and anchors for auricular prostheses.
Collapse
|
8
|
Seiwerth I, Brylok A, Schwesig R, Rahne T, Fröhlich L, Lauenroth A, Hullar TE, Plontke SK. Influence of Hearing Rehabilitation With Active Middle Ear and Bone Conduction Implants on Postural Control. Front Neurol 2022; 13:846999. [PMID: 35645964 PMCID: PMC9130604 DOI: 10.3389/fneur.2022.846999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Accepted: 03/30/2022] [Indexed: 11/30/2022] Open
Abstract
Background As audition also seems to contribute to balance control, additionally to visual, proprioceptive, and vestibular information, we hypothesize that hearing rehabilitation with active middle ear and bone conduction implants can influence postural control. Methods In a prospective explorative study, the impact of hearing rehabilitation with active middle ear [Vibrant Soundbrige (VSB), MED-EL, Innsbruck, Austria] and bone conduction implants [Bonebridge (BB), MED-EL, Innsbruck, Austria] on postural control in adults was examined in three experiments. Vestibulospinal control was measured by cranio-corpography (CCG), trunk sway velocity (°/s) by the Standard Balance Deficit Test (SBDT), and postural stability with a force plate system, each time in best aided (BA) and unaided (UA) condition with frontal-noise presentation (Fastl noise, 65 dB SPL), followed by subjective evaluation, respectively. Results In 26 subjects [age 55.0 ± 12.8 years; unilateral VSB/BB: n = 15; bilateral VSB/BB: n = 3, bimodal (VSB/BB + hearing aid): n = 8], CCG-analysis showed no difference between BA and UA conditions for the means of distance, angle of displacement, and angle of rotation, respectively. Trunk sway measurements revealed a relevant increase of sway in standing on foam (p = 0.01, r = 0.51) and a relevant sway reduction in walking (p = 0.026, r = 0.44, roll plane) in BA condition. Selective postural subsystem analysis revealed a relevant increase of the vestibular component in BA condition (p = 0.017, r = 0.47). As measured with the Interactive Balance System (IBS), 42% of the subjects improved stability (ST) in BA condition, 31% showed no difference, and 27% deteriorated, while no difference was seen in comparison of means. Subjectively, 4–7% of participants felt that noise improved their balance, 73–85% felt no difference, and 7–23% reported deterioration by noise. Furthermore, 46–50% reported a better task performance in BA condition; 35–46% felt no difference and 4–15% found the UA situation more helpful. Conclusions Subjectively, approximately half of the participants reported a benefit in task performance in BA condition. Objectively, this could only be shown in one mobile SBDT-task. Subsystem analysis of trunk sway provided insights in multisensory reweighting mechanisms.
Collapse
Affiliation(s)
- Ingmar Seiwerth
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
- *Correspondence: Ingmar Seiwerth
| | - Antonia Brylok
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| | - René Schwesig
- Department of Orthopaedic and Trauma Surgery, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| | - Torsten Rahne
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| | - Laura Fröhlich
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| | - Andreas Lauenroth
- Department of Orthopaedic and Trauma Surgery, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| | - Timothy E. Hullar
- Veterans Administration (VA) Portland National Center for Rehabilitative Auditory Research and Department of Otolaryngology-Head and Neck Surgery, Oregon Health and Science University, Portland, OR, United States
| | - Stefan K. Plontke
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| |
Collapse
|
9
|
Lailach S, Zahnert T. Results and Quality of Life after Implantation of Active Middle Ear Implants. Laryngorhinootologie 2022; 101:S3-S35. [PMID: 35605611 DOI: 10.1055/a-1647-8616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The provision of implantable hearing aids represents an area with high development and innovation potential. On the one hand, this review article provides an overview of current indication criteria for the treatment with active middle ear implants. On the other hand, outcome parameters as well as functional results after implantation of active middle ear implants are demonstrated and discussed. The focus is mainly placed on audiological results as well as the subjective health status. "Patient Reported Outcome Measures" (PROMs) have become an integral part of the evaluation of hearing implant treatment. Due to low evidence level criteria, the study situation regarding audiological as well as subjective outcome parameters is not satisfactory. The lack of an international consensus on accepted outcome parameters makes a meta-analytical analysis of results immensely difficult. In the studies published to date, patients with sensorineural hearing loss and patients with conductive or mixed hearing loss offered better speech recognition after implantation of an active middle ear implant compared to conventional hearing aids. Current analyses show a significant improvement in general as well as hearing-specific quality of life after implantation of an active middle ear implant. To date, no validated, hearing-specific quality-of-life measurement instruments exist for assessing the success of fitting in children. Especially in children with complex malformations of the outer ear and the middle ear, excellent audiological results were shown. However, these results need to be substantiated by quality-of-life measurements in future.
Collapse
Affiliation(s)
- Susen Lailach
- Universitätsklinikum Dresden Klinik und Poliklinik für Hals-, Nasen-, Ohrenheilkunde, Kopf- und Halschirurgie (Klinikdirektor: Prof. Dr.med. Dr. h.c. Thomas Zahnert) Dresden
| | - Thomas Zahnert
- Universitätsklinikum Dresden Klinik und Poliklinik für Hals-, Nasen-, Ohrenheilkunde, Kopf- und Halschirurgie (Klinikdirektor: Prof. Dr.med. Dr. h.c. Thomas Zahnert) Dresden
| |
Collapse
|
10
|
Buhl C, Schindler V, Pfiffner F, Veraguth D, Huber A, Röösli C. Subjective Sound Quality Detection (HISQUI) over Time after Vibrant Soundbridge Implantation. J Clin Med 2022; 11:jcm11071811. [PMID: 35407420 PMCID: PMC9000017 DOI: 10.3390/jcm11071811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 03/21/2022] [Accepted: 03/23/2022] [Indexed: 02/01/2023] Open
Abstract
Background: To evaluate the long-term audiological outcomes combined with the Hearing Implant Sound Quality Index (HISQUI) after Vibrant Soundbridge (VSB) implantation. Methods: Prospective recall cohort study of patients who received a VSB in a tertiary academic medical center between 1996 and 2017. Air conduction (AC) and bone conduction (BC), sound field thresholds in aided and unaided conditions, and speech discrimination in noise (Oldenburger sentence test) were measured. Postoperative results were compared with preoperative audiograms. Furthermore, the HISQUI was evaluated. Results: Ten patients (eleven implants) were included, the mean follow up period was nine years. The mean AC threshold preoperatively was between 63 and 70 dB, and the BC was between 38 and 49 dB from 500 to 4000 Hz. In the free-field audiogram, the mean threshold was between 61 and 77 dB unaided vs. between 28 and 52 dB in the aided condition. The average signal to noise ratio (SNR) in the Oldenburger sentence test in the unaided condition was 10 dB ± 6.7 dB vs. 2 dB ± 5.4 dB in the aided condition. Three patients reported a good to very good hearing result, four patients a moderate, and three patients a poor hearing result. There was a significant association between the years of implantation and the HISQUI (p = 0.013), as well as a significant decrease by 14 HISQUI points per 10 dB SPL decline (SE 5.2, p = 0.023). There was a significant difference between the change of BC over the years and the HISQUI, as well as the number of years after implantation and the HISQUI. On average, per dB decrease in BC, the HISQUI decreases by 1.4 points, and every year after implantation the HISQUI decreases by 2.7 points. Conclusions: The aided threshold in free field and speech understanding in noise improved significantly with VSB. An increase over time of BC thresholds was observed as well as a decrease in HISQUI score. This decrease in BC thresholds over time may be due to presbycusis. Therefore, monitoring of these patients over time should be considered to discuss alternative hearing rehabilitation measures in a timely manner.
Collapse
Affiliation(s)
- Christof Buhl
- Department of Otorhinolaryngology-Head and Neck Surgery, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland; (C.B.); (F.P.); (D.V.); (A.H.)
| | - Valeria Schindler
- Department of Gastroenterology, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland;
| | - Flurin Pfiffner
- Department of Otorhinolaryngology-Head and Neck Surgery, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland; (C.B.); (F.P.); (D.V.); (A.H.)
| | - Dorothe Veraguth
- Department of Otorhinolaryngology-Head and Neck Surgery, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland; (C.B.); (F.P.); (D.V.); (A.H.)
| | - Alexander Huber
- Department of Otorhinolaryngology-Head and Neck Surgery, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland; (C.B.); (F.P.); (D.V.); (A.H.)
| | - Christof Röösli
- Department of Otorhinolaryngology-Head and Neck Surgery, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland; (C.B.); (F.P.); (D.V.); (A.H.)
- Correspondence: ; Tel.: +41-44-255-1111
| |
Collapse
|
11
|
Fröhlich L, Müller A, Kropp MH, Mir-Salim P, Dziemba O, Oberhoffner T, Plontke SK, Rahne T. Active Middle Ear Implant Evoked Auditory Brainstem Response Intensity-Latency Characteristics. Front Neurol 2022; 12:739906. [PMID: 35126279 PMCID: PMC8810535 DOI: 10.3389/fneur.2021.739906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 12/16/2021] [Indexed: 11/21/2022] Open
Abstract
Objective To analyze intensity-latency functions of intraoperative auditory evoked brainstem responses (ABRs) to stimulation by the Vibrant Soundbridge (VSB) active middle ear implant with respect to coupling efficiency, VSB evoked ABR thresholds, and coupling modality [oval window (OW) placement vs. Incus placement and vs. round window (RW) placement]. Study Design Exploratory study. Setting Bi-centric study at tertiary referral centers. Patients Twenty-four patients (10 female, 14 male, mean age: 58 years) who received a VSB. Outcome Measures Wave-V intensity-latency functions of intraoperative VSB evoked ABRs using a modified audio processor programmed to preoperative bone conduction thresholds for stimulation. Threshold level correction to coupling efficiency and ABR thresholds. Individual plots and exponential function fits. Results After ABR threshold level correction, the latency functions could be aligned. A large variance of latencies was observed at individual threshold level. Wave-V latency was longest in the Incus placement subgroup (9.73 ms, SD: 1.04) as compared to OW placement subgroup (9.47 ms, SD: 1.05), with the shortest latency in the RW placement subgroup (8.99 ms, SD: 0.68). For increasing stimulation levels, the variance decreased with intensity-latency function slopes converging toward a steady-state (saturation) latency caused by saturation of audio processor (stimulation) gain. Latency saturation was reached at a stimulation level of 50 dB nHL for the OW placement subgroup, 35 dB nHL for the Incus placement subgroup, and 30 dB nHL for the RW placement subgroup. The latency and saturation results indicated decreased dynamic range for RW placement, i.e., reverse stimulation. Conclusions VSB evoked ABR wave-V intensity-latency function slopes were similar to acoustic stimulation at high stimulation levels with a shift toward longer latencies caused by audio processor signal delay. Saturation of latencies occurred for higher stimulation levels due to saturation of audio processor gain. Thus, the analysis of VSB evoked intensity-latency functions appears to allow for the objective assessment of a patient's individual dynamic range. This can further improve diagnostics as well as intraoperative and postoperative quality control.
Collapse
Affiliation(s)
- Laura Fröhlich
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, Halle, Germany
- *Correspondence: Laura Fröhlich
| | - Alexander Müller
- Department of Otorhinolaryngology, Head and Neck Surgery, Friedrichshain Clinic, Vivantes Hearing Center, Berlin, Germany
| | - Miriam H. Kropp
- Department of Otorhinolaryngology, Head and Neck Surgery, Friedrichshain Clinic, Vivantes Hearing Center, Berlin, Germany
| | - Parwis Mir-Salim
- Department of Otorhinolaryngology, Head and Neck Surgery, Friedrichshain Clinic, Vivantes Hearing Center, Berlin, Germany
| | - Oliver Dziemba
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medicine of Greifswald, Greifswald, Germany
| | - Tobias Oberhoffner
- Department of Otorhinolaryngology, Head and Neck Surgery “Otto Körner”, Rostock University Medical Center, Rostock, Germany
| | - Stefan K. Plontke
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, Halle, Germany
| | - Torsten Rahne
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, Halle, Germany
| |
Collapse
|
12
|
Systematic and audiological indication criteria for bone conduction devices and active middle ear implants. Hear Res 2021; 421:108424. [PMID: 34987018 DOI: 10.1016/j.heares.2021.108424] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 12/02/2021] [Accepted: 12/22/2021] [Indexed: 01/11/2023]
Abstract
Certain patients with conductive or mixed hearing loss can benefit from bone-conduction hearing devices or active middle ear implants. Available devices differ in coupling site, energy transfer from the sound processor to the implant, and the active or passive actuator technology. The audiological benefit of those devices depends on the maximum stable power output and the noise floor of the device, the degree and expected stability of the sensorineural hearing loss and the coupling efficiency with the aim on achieving a minumum of 30-35 dB effective dynamic range. The choice of the device is often a trade-off between the optimal audiological solution with respect to the hearing loss, technical device-related parameters and the expected coupling efficiency, the optimal surgical solution with respect to patho-anatomical aspects, device dimensions and the coupling site, invasiveness or surgical risks, and other patient factors with respect to the patients' wish and expectations, social aspects, device usability and connectivity. This review article lists all currently available implantable and conventional bone-conduction hearing devices and active middle ear implants with respect to technical features like maximum power output, market availability, and the expected effective output dynamic range.
Collapse
|
13
|
Grueninger I, Canis M, Spiegel JL, Müller J. Combination of Direct Oval Window Vibroplasty With Customized Partial Ossicular Replacement Prosthesis (PORP): A Novel Reconstruction Technique to Rehabilitate Mixed Hearing Loss. Otol Neurotol 2021; 42:1507-1514. [PMID: 34267101 DOI: 10.1097/mao.0000000000003278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Hearing rehabilitation with an active middle ear implant (AMEI) in patients with mixed hearing loss (MHL) after multiple ear surgeries is surgically challenging and requires individual solutions in some cases. Our objective was to introduce a feasible novel technique for direct oval window vibroplasty (OW vibroplasty) using a partial ossicular replacement prosthesis (PORP) to ensure stability and enable active and passive sound transmission. DESIGN Four patients with MHL following multiple middle ear surgeries and indication for an AMEI received direct OW vibroplasty in combination with a customized PORP between the enwrapped actuator and reconstructed tympanic membrane (TM). RESULTS Postoperative bone conduction was stable in all patients. All patients benefitted from the AMEI in combination with PORP with a mean functional gain of 31.5 ± 17.0 dB. Mean aided postoperative pure tone average was 27.3 ± 2.6 dB. Speech discrimination in quiet at 65 dB with the German Language Freiburg Monosyllabic Test improved for all patients to 68.8 ± 6.3% and in noise with the German Language Oldenburger Sentence Test to -10.4 ± 3.3 dB SNR. No complications were observed. CONCLUSIONS This novel technique of direct OW vibroplasty extends the portfolio of reconstructive middle ear procedures by combining an intraoperatively customized "off-the-shelf" PORP as a coupler between floating mass transducer (FMT) and a cartilage TM. We found satisfying functional hearing results. Benefits of the reported technique comprise 1) stabilization and optimized coupling of the reconstruction, 2) possibility of passive sound transmission, 3) general feasibility due to great availability of a regular PORP, and 4) flexibility in bridging of large gaps between TM and actuator.
Collapse
Affiliation(s)
- Ivo Grueninger
- Department of Otorhinolaryngology, University Hospital, LMU Munich, Munich, Germany
| | | | | | | |
Collapse
|
14
|
Banakis Hartl RM, Jenkins HA. Implantable Hearing Aids: Where are we in 2020? Laryngoscope Investig Otolaryngol 2020; 5:1184-1191. [PMID: 33364411 PMCID: PMC7752069 DOI: 10.1002/lio2.495] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Revised: 09/29/2020] [Accepted: 10/29/2020] [Indexed: 12/04/2022] Open
Abstract
Beginning in the late 20th century, implantable hearing aids were developed and used as an alternative for individuals who were unable to tolerate conventional hearing aids. Since that time, several devices have been developed, with four currently remaining on the international market (Med-el Vibrant Soundbridge, Envoy Esteem, Ototronix MAXUM, and Cochlear Carina). This review will briefly examine the history of middle ear implant development, describe current available devices, evaluate the benefits and limits of the technology, and consider the future directions of research in the field of implantable hearing aids.
Collapse
Affiliation(s)
| | - Herman A. Jenkins
- Department of OtolaryngologyUniversity of Colorado School of MedicineAuroraColoradoUSA
| |
Collapse
|
15
|
Fröhlich L, Rahne T, Plontke SK, Oberhoffner T, Dahl R, Mlynski R, Dziemba O, Aristeidou A, Gadyuchko M, Koscielny S, Hoth S, Kropp MH, Mir-Salim P, Müller A. Intraoperative quantification of floating mass transducer coupling quality in active middle ear implants: a multicenter study. Eur Arch Otorhinolaryngol 2020; 278:2277-2288. [PMID: 32880736 PMCID: PMC8165065 DOI: 10.1007/s00405-020-06313-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Accepted: 08/19/2020] [Indexed: 11/28/2022]
Abstract
Purpose Evaluating the effectiveness of intraoperative auditory brainstem responses (ABRs) to stimulation by the Vibrant Soundbridge (VSB) active middle ear implant for quantifying the implant’s floating mass transducer (FMT) coupling quality. Methods In a diagnostic multicentric study, patients (> 18 years) who received a VSB with different coupling modalities were included. Pre- and postoperative bone conduction thresholds, intraoperative VSB-evoked ABR thresholds (VSB-ABR) using a modified audio processor programmed to preoperative bone conduction thresholds, postoperative vibrogram thresholds, and postoperative VSB-ABR thresholds were measured. Coupling quality was calculated from the difference between the pure tone average at 1000, 2000, and 4000 Hz (3PTA) vibrogram and postoperative 3PTA bone conduction thresholds. Results Twenty-three patients (13 males, 10 females, mean age 56.6 (± 12.5) years) were included in the study. Intraoperative VSB-ABR response thresholds could be obtained in all except one patient where the threshold was > 30 dB nHL. Postoperatively, an insufficient coupling of 36.7 dB was confirmed in this patient. In a Bland–Altman analysis of the intraoperative VSB-ABRs and coupling quality, the limits of agreement exceeded ± 10 dB, i.e., the maximum allowed difference considered as not clinically important but the variation was within the general precision of auditory brainstem responses to predict behavioral thresholds. Five outliers were identified. In two patients, the postoperative VSB-ABR thresholds were in agreement with the coupling quality, indicating a change of coupling before the postoperative testing. Conclusion The response thresholds recorded in this set-up have the potential to predict the VSB coupling quality and optimize postoperative audiological results.
Collapse
Affiliation(s)
- Laura Fröhlich
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, University Medicine Halle (Saale), Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany.
| | - Torsten Rahne
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, University Medicine Halle (Saale), Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany
| | - Stefan K Plontke
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, University Medicine Halle (Saale), Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany
| | - Tobias Oberhoffner
- Department of Otorhinolaryngology, Head and Neck Surgery "Otto Körner", Rostock University Medical Center, Rostock, Germany
| | - Rüdiger Dahl
- Department of Otorhinolaryngology, Head and Neck Surgery "Otto Körner", Rostock University Medical Center, Rostock, Germany
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery "Otto Körner", Rostock University Medical Center, Rostock, Germany
| | - Oliver Dziemba
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medicine of Greifswald, Greifswald, Germany
| | - Aristotelis Aristeidou
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medicine of Greifswald, Greifswald, Germany
| | - Maria Gadyuchko
- Department of Otorhinolaryngology, Institute of Phoniatry/Pedaudiology, Jena University Hospital, Friedrich-Schiller-University Jena, Jena, Germany.,Department of Otorhinolaryngology, Helios Clinic, Erfurt, Germany
| | - Sven Koscielny
- Department of Otorhinolaryngology, Institute of Phoniatry/Pedaudiology, Jena University Hospital, Friedrich-Schiller-University Jena, Jena, Germany
| | - Sebastian Hoth
- Department of ENT, University of Heidelberg, Heidelberg, Germany
| | - Miriam H Kropp
- ORL Department Friedrichshain Clinic, Vivantes Hearing Center, Berlin, Germany
| | - Parwis Mir-Salim
- ORL Department Friedrichshain Clinic, Vivantes Hearing Center, Berlin, Germany
| | - Alexander Müller
- ORL Department Friedrichshain Clinic, Vivantes Hearing Center, Berlin, Germany
| |
Collapse
|