Di Stadio A, Ralli M, Kaski D, Koohi N, Gioacchini FM, Kysar JW, Lalwani AK, Warnecke A, Bernitsas E. Exploring Inner Ear and Brain Connectivity through Perilymph Sampling for Early Detection of Neurological Diseases: A Provocative Proposal. Brain Sci 2024; 14:621. [PMID: 38928621 PMCID: PMC11201480 DOI: 10.3390/brainsci14060621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Revised: 06/17/2024] [Accepted: 06/19/2024] [Indexed: 06/28/2024] Open
Abstract
Recent evidence shows that it is possible to identify the elements responsible for sensorineural hearing loss, such as pro-inflammatory cytokines and macrophages, by performing perilymph sampling. However, current studies have only focused on the diagnosis of such as otologic conditions. Hearing loss is a feature of certain neuroinflammatory disorders such as multiple sclerosis, and sensorineural hearing loss (SNHL) is widely detected in Alzheimer's disease. Although the environment of the inner ear is highly regulated, there are several communication pathways between the perilymph of the inner ear and cerebrospinal fluid (CSF). Thus, examination of the perilymph may help understand the mechanism behind the hearing loss observed in certain neuroinflammatory and neurodegenerative diseases. Herein, we review the constituents of CSF and perilymph, the anatomy of the inner ear and its connection with the brain. Then, we discuss the relevance of perilymph sampling in neurology. Currently, perilymph sampling is only performed during surgical procedures, but we hypothesize a simplified and low-invasive technique that could allow sampling in a clinical setting with the same ease as performing an intratympanic injection under direct visual check. The use of this modified technique could allow for perilymph sampling in people with hearing loss and neuroinflammatory/neurodegenerative disorders and clarify the relationship between these conditions; in fact, by measuring the concentration of neuroinflammatory and/or neurodegenerative biomarkers and those typically expressed in the inner ear in aging SNHL, it could be possible to understand if SNHL is caused by aging or neuroinflammation.
Collapse
Affiliation(s)
- Arianna Di Stadio
- Department GF Ingrassia, University of Catania, 95131 Catania, Italy
- Sense Research Unit, Department of Clinical and Movement Neurosciences, UCL Queen Square Institute of Neurology, London WC1N 3BG, UK; (D.K.); (N.K.)
| | - Massimo Ralli
- Organ of Sense Department, University La Sapienza, 00185 Rome, Italy;
| | - Diego Kaski
- Sense Research Unit, Department of Clinical and Movement Neurosciences, UCL Queen Square Institute of Neurology, London WC1N 3BG, UK; (D.K.); (N.K.)
| | - Nehzat Koohi
- Sense Research Unit, Department of Clinical and Movement Neurosciences, UCL Queen Square Institute of Neurology, London WC1N 3BG, UK; (D.K.); (N.K.)
| | - Federico Maria Gioacchini
- Ear, Nose, and Throat Unit, Department of Clinical and Molecular Sciences, Polytechnic University of Marche, 60020 Ancona, Italy;
| | - Jeffrey W. Kysar
- Otolaryngology—Head and Neck Department, Columbia University, New York, NY 10032, USA; (J.W.K.); (A.K.L.)
| | - Anil K. Lalwani
- Otolaryngology—Head and Neck Department, Columbia University, New York, NY 10032, USA; (J.W.K.); (A.K.L.)
| | - Athanasia Warnecke
- Department of Otolaryngology—Head and Neck Surgery, Hannover Medical School, 30625 Hannover, Germany;
| | - Evanthia Bernitsas
- Multiple Sclerosis Center, Neurology Department, Wayne State University, Detroit, MI 48201, USA;
| |
Collapse
|
2
|
Geys M, Sijgers L, Dobrev I, Dalbert A, Röösli C, Pfiffner F, Huber A. ZH-ECochG Bode Plot: A Novel Approach to Visualize Electrocochleographic Data in Cochlear Implant Users. J Clin Med 2024; 13:3470. [PMID: 38929998 PMCID: PMC11205027 DOI: 10.3390/jcm13123470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 06/08/2024] [Accepted: 06/12/2024] [Indexed: 06/28/2024] Open
Abstract
Background: Various representations exist in the literature to visualize electrocochleography (ECochG) recordings along the basilar membrane (BM). This lack of generalization complicates comparisons within and between cochlear implant (CI) users, as well as between publications. This study synthesized the visual representations available in the literature via a systematic review and provides a novel approach to visualize ECochG data in CI users. Methods: A systematic review was conducted within PubMed and EMBASE to evaluate studies investigating ECochG and CI. Figures that visualized ECochG responses were selected and analyzed. A novel visualization of individual ECochG data, the ZH-ECochG Bode plot (ZH = Zurich), was devised, and the recordings from three CI recipients were used to demonstrate and assess the new framework. Results: Within the database search, 74 articles with a total of 115 figures met the inclusion criteria. Analysis revealed various types of representations using different axes; their advantages were incorporated into the novel visualization framework. The ZH-ECochG Bode plot visualizes the amplitude and phase of the ECochG recordings along the different tonotopic regions and angular insertion depths of the recording sites. The graph includes the pre- and postoperative audiograms to enable a comparison of ECochG responses with the audiometric profile, and allows different measurements to be shown in the same graph. Conclusions: The ZH-ECochG Bode plot provides a generalized visual representation of ECochG data, using well-defined axes. This will facilitate the investigation of the complex ECochG potentials generated along the BM and allows for better comparisons of ECochG recordings within and among CI users and publications. The scripts used to construct the ZH-ECochG Bode plot are provided by the authors.
Collapse
Affiliation(s)
- Marlies Geys
- Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland
| | | | | | | | | | | | | |
Collapse
|
3
|
Dalbert A, Weder S. [Application of extra- and intracochlear electrocochleography during and after cochlear implantation]. HNO 2024:10.1007/s00106-024-01481-4. [PMID: 38761228 DOI: 10.1007/s00106-024-01481-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/19/2024] [Indexed: 05/20/2024]
Abstract
Electrocochleography (ECochG) represents a promising approach for monitoring cochlear function during cochlear implantation and for investigating the causes of residual cochlear function loss after implantation. This paper provides an overview of the current research and application status of ECochG, both during and after cochlear implantation. Intraoperative ECochG can be conducted either via the implant itself or an extracochlear measuring electrode. Postoperative ECochG recordings are also feasible via the implant. Various studies have demonstrated that a significant decrease in ECochG amplitude during electrode insertion correlates with an increased risk of losing residual cochlear function, with critical cochlear events occurring primarily towards the end of the insertion. Postoperative data suggest that the loss of cochlear function mainly occurs in the early postoperative phase. Future research directions include the automation and objectification of signal analysis, as well as a more in-depth investigation into the underlying mechanisms of these signal changes.
Collapse
Affiliation(s)
- Adrian Dalbert
- Klinik für Ohren‑, Nasen‑, Hals- und Gesichtschirurgie, Universitätsspital Zürich, Zürich, Schweiz
| | - Stefan Weder
- Universitätsklinik für Hals‑, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie Inselspital, Universitätsspital Bern, Freiburgstrasse 20, 3012, Bern, Schweiz.
| |
Collapse
|
4
|
Haumann S, Timm ME, Büchner A, Lenarz T, Salcher RB. Intracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea. Trends Hear 2024; 28:23312165241248973. [PMID: 38717441 PMCID: PMC11080744 DOI: 10.1177/23312165241248973] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 02/23/2024] [Accepted: 04/04/2024] [Indexed: 05/12/2024] Open
Abstract
To preserve residual hearing during cochlear implant (CI) surgery it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring). A promising method is electrocochleography (ECochG). Within this project the relations between intracochlear ECochG recordings, position of the recording contact in the cochlea with respect to anatomy and frequency and preservation of residual hearing were investigated. The aim was to better understand the changes in ECochG signals and whether these are due to the electrode position in the cochlea or to trauma generated during insertion. During and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed using the CI electrode (MED-EL). During insertion, the recordings were performed at discrete insertion steps on electrode contact 1. After insertion as well as postoperatively the recordings were performed at different electrode contacts. The electrode location in the cochlea during insertion was estimated by mathematical models using preoperative clinical imaging, the postoperative location was measured using postoperative clinical imaging. The recordings were analyzed from six adult CI recipients. In the four patients with good residual hearing in the low frequencies the signal amplitude rose with largest amplitudes being recorded closest to the generators of the stimulation frequency, while in both cases with severe pantonal hearing losses the amplitude initially rose and then dropped. This might be due to various reasons as discussed in the following. Our results indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.
Collapse
Affiliation(s)
- Sabine Haumann
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Max E. Timm
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Andreas Büchner
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Rolf B. Salcher
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| |
Collapse
|
5
|
Haumann S, Mynarek (née Bradler) M, Maier H, Helmstaedter V, Büchner A, Lenarz T, Teschner MJ. Does Intraoperative Extracochlear Electrocochleography Correlate With Postoperative Audiometric Hearing Thresholds in Cochlear Implant Surgery? A Retrospective Analysis of Cochlear Monitoring. Trends Hear 2024; 28:23312165241252240. [PMID: 38715410 PMCID: PMC11080760 DOI: 10.1177/23312165241252240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 04/09/2024] [Accepted: 04/16/2024] [Indexed: 05/12/2024] Open
Abstract
In recent years, tools for early detection of irreversible trauma to the basilar membrane during hearing preservation cochlear implant (CI) surgery were established in several clinics. A link with the degree of postoperative hearing preservation in patients was investigated, but patient populations were usually small. Therefore, this study's aim was to analyze data from intraoperative extracochlear electrocochleography (ECochG) recordings for a larger group.During hearing preservation CI surgery, extracochlear recordings were made before, during, and after CI electrode insertion using a cotton wick electrode placed at the promontory. Before and after insertion, amplitudes and stimulus response thresholds were recorded at 250, 500, and 1000 Hz. During insertion, response amplitudes were recorded at one frequency and one stimulus level. Data from 121 patient ears were analyzed.The key benefit of extracochlear recordings is that they can be performed before, during, and after CI electrode insertion. However, extracochlear ECochG threshold changes before and after CI insertion were relatively small and did not independently correlate well with hearing preservation, although at 250 Hz they added some significant information. Some tendencies-although no significant relationships-were detected between amplitude behavior and hearing preservation. Rising amplitudes seem favorable and falling amplitudes disadvantageous, but constant amplitudes do not appear to allow stringent predictions.Extracochlear ECochG measurements seem to only partially realize expected benefits. The questions now are: do gains justify the effort, and do other procedures or possible combinations lead to greater benefits for patients?
Collapse
Affiliation(s)
- Sabine Haumann
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Marlene Mynarek (née Bradler)
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Hannes Maier
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Victor Helmstaedter
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Andreas Büchner
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Magnus J. Teschner
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
- Department of Otorhinolaryngology, Proselis Klinikum Recklinghausen, Recklinghausen, Germany
| |
Collapse
|
6
|
Scheperle R, Etler C, Oleson J, Dunn C, Kashani R, Claussen A, Gantz BJ, Hansen MR. Evaluation of Real-Time Intracochlear Electrocochleography for Guiding Cochlear Implant Electrode Array Position. J Clin Med 2023; 12:7409. [PMID: 38068461 PMCID: PMC10707171 DOI: 10.3390/jcm12237409] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 11/12/2023] [Accepted: 11/24/2023] [Indexed: 02/12/2024] Open
Abstract
This study evaluates intracochlear electrocochleography (ECochG) for real-time monitoring during cochlear implantation. One aim tested whether adjusting the recording electrode site would help differentiate between atraumatic and traumatic ECochG amplitude decrements. A second aim assessed whether associations between ECochG amplitude decrements and post-operative hearing loss were weaker when considering hearing sensitivity at the ECochG stimulus frequency compared to a broader frequency range. Eleven adult cochlear implant recipients who were candidates for electro-acoustic stimulation participated. Single-frequency (500-Hz) ECochG was performed during cochlear implantation; the amplitude of the first harmonic of the difference waveform was considered. Post-operative hearing preservation at 500 Hz ranged from 0 to 94%. The expected relationship between ECochG amplitude decrements and hearing preservation was observed, though the trend was not statistically significant, and predictions were grossly inaccurate for two participants. Associations did not improve when considering alternative recording sites or hearing sensitivity two octaves above the ECochG stimulus frequency. Intracochlear location of a moving recording electrode is a known confound to real-time interpretation of ECochG amplitude fluctuations, which was illustrated by the strength of the correlation with ECochG amplitude decrements. Multiple factors contribute to ECochG amplitude patterns and to hearing preservation; these results highlight the confounding influence of intracochlear recording electrode location on the ECochG.
Collapse
Affiliation(s)
- Rachel Scheperle
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA; (C.E.); (C.D.); (R.K.); (A.C.); (B.J.G.); (M.R.H.)
| | - Christine Etler
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA; (C.E.); (C.D.); (R.K.); (A.C.); (B.J.G.); (M.R.H.)
| | - Jacob Oleson
- Department of Biostatistics, University of Iowa, Iowa City, IA 52242, USA
| | - Camille Dunn
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA; (C.E.); (C.D.); (R.K.); (A.C.); (B.J.G.); (M.R.H.)
| | - Rustin Kashani
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA; (C.E.); (C.D.); (R.K.); (A.C.); (B.J.G.); (M.R.H.)
- Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA
| | - Alexander Claussen
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA; (C.E.); (C.D.); (R.K.); (A.C.); (B.J.G.); (M.R.H.)
- Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA
| | - Bruce J. Gantz
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA; (C.E.); (C.D.); (R.K.); (A.C.); (B.J.G.); (M.R.H.)
- Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA
| | - Marlan R. Hansen
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA; (C.E.); (C.D.); (R.K.); (A.C.); (B.J.G.); (M.R.H.)
- Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA
- Department of Molecular Physiology and Biophysics, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA
| |
Collapse
|
7
|
Kirk JR, Smyth D, Dueck WF. A new paradigm of hearing loss and preservation with cochlear implants: Learnings from fundamental studies and clinical research. Hear Res 2023; 433:108769. [PMID: 37120894 DOI: 10.1016/j.heares.2023.108769] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 02/18/2023] [Accepted: 04/15/2023] [Indexed: 05/02/2023]
Abstract
In 2010 Cochlear initiated a coordinated preclinical research program to identify the factors and underlying mechanisms of acoustic hearing loss following cochlear implantation and device use. At its inception the program was structured around several major hypotheses implicated in the loss of acoustic hearing. The understanding of causes evolved over the course of the program, leading to an increased appreciation of the role of the biological response in post-implant hearing loss. A systematic approach was developed which mapped the cochlear implant journey along a timeline that considers all events in an individual's hearing history. By evaluating the available data in this context, rather than by discrete hypothesis testing, causative and associated factors may be more readily detected. This approach presents opportunities for more effective research management and may aid in identifying new prospects for intervention. Many of the outcomes of the research program apply beyond preservation of acoustic hearing to factors important to overall cochlear health and considerations for future therapies.
Collapse
Affiliation(s)
- Jonathon R Kirk
- Cochlear Limited, 1 University Avenue, Macquarie University, NSW 2109, Australia.
| | - Daniel Smyth
- Cochlear Limited, 1 University Avenue, Macquarie University, NSW 2109, Australia
| | - Wolfram F Dueck
- Cochlear Limited, 1 University Avenue, Macquarie University, NSW 2109, Australia
| |
Collapse
|
8
|
Jwair S, Ramekers D, Thomeer HGXM, Versnel H. Acute effects of cochleostomy and electrode-array insertion on compound action potentials in normal-hearing guinea pigs. Front Neurosci 2023; 17:978230. [PMID: 36845413 PMCID: PMC9945226 DOI: 10.3389/fnins.2023.978230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Accepted: 01/09/2023] [Indexed: 02/11/2023] Open
Abstract
Introduction Electrocochleography (ECochG) is increasingly used in cochlear implant (CI) surgery, in order to monitor the effect of insertion of the electrode array aiming to preserve residual hearing. However, obtained results are often difficult to interpret. Here we aim to relate changes in ECochG responses to acute trauma induced by different stages of cochlear implantation by performing ECochG at multiple time points during the procedure in normal-hearing guinea pigs. Materials and methods Eleven normal-hearing guinea pigs received a gold-ball electrode that was fixed in the round-window niche. ECochG recordings were performed during the four steps of cochlear implantation using the gold-ball electrode: (1) Bullostomy to expose the round window, (2) hand-drilling of 0.5-0.6 mm cochleostomy in the basal turn near the round window, (3) insertion of a short flexible electrode array, and (4) withdrawal of electrode array. Acoustical stimuli were tones varying in frequency (0.25-16 kHz) and sound level. The ECochG signal was primarily analyzed in terms of threshold, amplitude, and latency of the compound action potential (CAP). Midmodiolar sections of the implanted cochleas were analyzed in terms of trauma to hair cells, modiolar wall, osseous spiral lamina (OSL) and lateral wall. Results Animals were assigned to cochlear trauma categories: minimal (n = 3), moderate (n = 5), or severe (n = 3). After cochleostomy and array insertion, CAP threshold shifts increased with trauma severity. At each stage a threshold shift at high frequencies (4-16 kHz) was accompanied with a threshold shift at low frequencies (0.25-2 kHz) that was 10-20 dB smaller. Withdrawal of the array led to a further worsening of responses, which probably indicates that insertion and removal trauma affected the responses rather than the mere presence of the array. In two instances, CAP threshold shifts were considerably larger than threshold shifts of cochlear microphonics, which could be explained by neural damage due to OSL fracture. A change in amplitudes at high sound levels was strongly correlated with threshold shifts, which is relevant for clinical ECochG performed at one sound level. Conclusion Basal trauma caused by cochleostomy and/or array insertion should be minimized in order to preserve the low-frequency residual hearing of CI recipients.
Collapse
Affiliation(s)
- Saad Jwair
- Department of Otorhinolaryngology and Head and Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands,UMC Utrecht Brain Center, Utrecht University, Utrecht, Netherlands
| | - Dyan Ramekers
- Department of Otorhinolaryngology and Head and Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands,UMC Utrecht Brain Center, Utrecht University, Utrecht, Netherlands
| | - Hans G. X. M. Thomeer
- Department of Otorhinolaryngology and Head and Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands,UMC Utrecht Brain Center, Utrecht University, Utrecht, Netherlands
| | - Huib Versnel
- Department of Otorhinolaryngology and Head and Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands,UMC Utrecht Brain Center, Utrecht University, Utrecht, Netherlands,*Correspondence: Huib Versnel,
| |
Collapse
|
9
|
Summating Potential as Marker of Intracochlear Position in Bipolar Electrocochleography. Ear Hear 2023; 44:118-134. [PMID: 35894668 DOI: 10.1097/aud.0000000000001259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVES Cochlear implantation criteria include subjects with residual low-frequency hearing. To minimize implantation trauma and to avoid unwanted interactions of electric- and acoustic stimuli, it is often recommended to stop cochlear implantation before the cochlear implant (CI) reaches the cochlear partition with residual hearing, as determined by an audiogram. For this purpose, the implant can be used to record acoustically evoked signals during implantation, including cochlear compound action potentials (CAP), cochlear microphonics (CMs), and summating potentials (SPs). The former two have previously been used to monitor residual hearing in clinical settings. DESIGN In the present study we investigated the use of intracochlear, bipolar SP recordings to determine the exact cochlear position of the contacts of implanted CIs in guinea pig cochleae (n = 13). Polarity reversals of SPs were used as a functional marker of intracochlear position. Micro computed tomography (µCT) imaging and a modified Greenwood function were used to determine the cochleotopic positions of the contacts in the cochlea. These anatomical reconstructions were used to validate the SP-based position estimates. RESULTS The precision of the SP-based position estimation was on average within ± 0.37 octaves and was not impaired by moderate hearing loss caused by noise exposure after implantation. It is important to note that acute hearing impairment did not reduce the precision of the method. The cochleotopic position of CI accounted for ~70% of the variability of SP polarity reversals. Outliers in the dataset were associated with lateral CI positions. Last, we propose a simplified method to avoid implantation in functioning parts of the cochlea by approaching a predefined frequency region using bipolar SP recordings through a CI. CONCLUSIONS Bipolar SP recordings provide reliable information on electrode position in the cochlea. The position estimate remains reliable after moderate hearing loss. The technique presented here could be applied during CI surgery to monitor the CI approach to a predefined frequency region.
Collapse
|
10
|
Andrade JSCD, Baumhoff P, Cruz OLM, Lenarz T, Kral A. Cochlear implantation in an animal model documents cochlear damage at the tip of the implant. Braz J Otorhinolaryngol 2022; 88:546-555. [PMID: 33039317 PMCID: PMC9422412 DOI: 10.1016/j.bjorl.2020.07.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 07/13/2020] [Accepted: 07/30/2020] [Indexed: 11/28/2022] Open
Abstract
INTRODUCTION Electrocochleography has recently emerged as a diagnostic tool in cochlear implant surgery, purposing hearing preservation and optimal electrode positioning. OBJECTIVE In this experimental study, extra-cochlear potentials were obtained during cochlear implant surgery in guinea pigs. The aim was to determine electrophysiological changes indicating cochlear trauma after cochleostomy and after electrode implantation in different insertion depths. METHODS Normal-hearing guinea pigs (n = 14) were implanted uni- or bilaterally with a multichannel electrode. The extra-cochlear cochlear nerve action potentials were obtained in response to acoustic stimuli at specific frequencies before and after cochleostomy, and after introduction of the electrode bundle. After the electrophysiological experiments, the guinea pigs were euthanized and microtomography was performed, in order to determine the position of the electrode and to calculate of the depth of insertion. Based on the changes of amplitude and thresholds in relation to the stimulus frequency, the electrophysiological data and the position obtained by the microtomography reconstruction were compared. RESULTS Cochleostomy promoted a small electrophysiological impact, while electrode insertion caused changes in the amplitude of extra-cochlear electrophysiological potentials over a wide range of frequencies, especially in the deepest insertions. There was, however, preservation of the electrical response to low frequency stimuli in most cases, indicating a limited auditory impact in the intraoperative evaluation. The mean insertion depth of the apical electrodes was 5339.56 μm (±306.45 - 6 inserted contacts) and 4447.75 μm (±290.23 - 5 inserted contacts). CONCLUSIONS The main electrophysiological changes observed during surgical procedures occurred during implantation of the electrode, especially the deepest insertions, whereas the cochleostomy disturbed the potentials to a lesser extent. While hearing loss was often observed apical to the cochlear implant, it was possible to preserve low frequencies after insertion.
Collapse
Affiliation(s)
- José Santos Cruz de Andrade
- Universidade Federal de São Paulo (UNIFESP), Departamento de Otorrinolaringologia e Cirurgia de Cabeça e Pescoço, São Paulo, SP, Brazil; Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (Capes), Brasília, DF, Brazil; Institute of Audioneurotechnology (VIANNA) & Department of Experimental Otology, Department of Otolaryngology, Medical University Hannover, Hannover, Germany.
| | - Peter Baumhoff
- Institute of Audioneurotechnology (VIANNA) & Department of Experimental Otology, Department of Otolaryngology, Medical University Hannover, Hannover, Germany; Cluster of Excellence "Hearing4all", Hannover, Germany
| | - Oswaldo Laércio Mendonça Cruz
- Universidade Federal de São Paulo (UNIFESP), Departamento de Otorrinolaringologia e Cirurgia de Cabeça e Pescoço, São Paulo, SP, Brazil; Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (Capes), Brasília, DF, Brazil
| | - Thomas Lenarz
- Institute of Audioneurotechnology (VIANNA) & Department of Experimental Otology, Department of Otolaryngology, Medical University Hannover, Hannover, Germany; Cluster of Excellence "Hearing4all", Hannover, Germany
| | - Andrej Kral
- Institute of Audioneurotechnology (VIANNA) & Department of Experimental Otology, Department of Otolaryngology, Medical University Hannover, Hannover, Germany; Cluster of Excellence "Hearing4all", Hannover, Germany
| |
Collapse
|
11
|
Peter MS, Warnecke A, Staecker H. A Window of Opportunity: Perilymph Sampling from the Round Window Membrane Can Advance Inner Ear Diagnostics and Therapeutics. J Clin Med 2022; 11:jcm11020316. [PMID: 35054010 PMCID: PMC8781055 DOI: 10.3390/jcm11020316] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 12/29/2021] [Accepted: 01/06/2022] [Indexed: 12/12/2022] Open
Abstract
In the clinical setting, the pathophysiology of sensorineural hearing loss is poorly defined and there are currently no diagnostic tests available to differentiate between subtypes. This often leaves patients with generalized treatment options such as steroids, hearing aids, or cochlear implantation. The gold standard for localizing disease is direct biopsy or imaging of the affected tissue; however, the inaccessibility and fragility of the cochlea make these techniques difficult. Thus, the establishment of an indirect biopsy, a sampling of inner fluids, is needed to advance inner ear diagnostics and allow for the development of novel therapeutics for inner ear disease. A promising source is perilymph, an inner ear liquid that bathes multiple structures critical to sound transduction. Intraoperative perilymph sampling via the round window membrane of the cochlea has been successfully used to profile the proteome, metabolome, and transcriptome of the inner ear and is a potential source of biomarker discovery. Despite its potential to provide insight into inner ear pathologies, human perilymph sampling continues to be controversial and is currently performed only in conjunction with a planned procedure where the inner ear is opened. Here, we review the safety of procedures in which the inner ear is opened, highlight studies where perilymph analysis has advanced our knowledge of inner ear diseases, and finally propose that perilymph sampling could be done as a stand-alone procedure, thereby advancing our ability to accurately classify sensorineural hearing loss.
Collapse
Affiliation(s)
- Madeleine St. Peter
- Department of Otolaryngology-Head & Neck Surgery, University of Kansas Medical Center, Kansas City, KS 66160, USA;
| | - Athanasia Warnecke
- Department of Otolaryngology Head and Neck Surgery, Hannover Medical School, D-30625 Hanover, Germany;
| | - Hinrich Staecker
- Department of Otolaryngology-Head & Neck Surgery, University of Kansas Medical Center, Kansas City, KS 66160, USA;
- Correspondence:
| |
Collapse
|
12
|
Implications of Phase Changes in Extracochlear Electrocochleographic Recordings During Cochlear Implantation. Otol Neurotol 2021; 43:e181-e190. [PMID: 34772884 DOI: 10.1097/mao.0000000000003414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To assess the prevalence and implications of phase changes in extracochlear electrocochleography (ECochG) recordings during cochlear implantation. MATERIALS AND METHODS Extracochlear ECochG recordings were performed before and after insertion of the cochlear implant (CI) electrode by a recording electrode placed on the promontory. Acoustic stimuli were tone bursts at 250, 500, 750, and 1,000 Hz. The pure tone average (PTA) was determined before and approximately 4 weeks after surgery. RESULTS Extracochlear ECochG recordings in 69 ears of 68 subjects were included. At 250 Hz, the mean phase change was 43° (n = 50, standard deviation (SD) 44°), at 500 Hz 36° (n = 64, SD 36°), at 750 Hz 33° (n = 42, SD 39°), and at 1,000 Hz 22° (n = 54, SD 27°). Overall, in 48 out of 210 ECochG recordings a phase change of ≥45° (23%) was detectable. Ears with an amplitude drop >3 dB and a phase change ≥45° (n = 3) had a complete or near complete loss of residual cochlear function in all cases. A phase change of ≥90° in one recording was not associated with a larger amplitude change of the ECochG signal (1.9 dB vs. -0.9 dB, p = 0.1052, n = 69), but with a significantly larger postoperative hearing loss (17 dB vs. 26 dB, p = 0.0156, n = 69). CONCLUSIONS Phase changes occur regularly in extracochlear ECochG recordings during cochlear implantation. Phase changes of ≥90° with or without amplitude changes in the ECochG signal are associated with a larger postoperative hearing loss and could therefore represent an independent marker for cochlear trauma or changes of inner ear mechanics relevant for the postoperative hearing outcome.
Collapse
|
13
|
Clinical Utility of Intraoperative Electrocochleography (ECochG) During Cochlear Implantation: A Systematic Review and Quantitative Analysis. Otol Neurotol 2021; 42:363-371. [PMID: 33347054 DOI: 10.1097/mao.0000000000002996] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To evaluate the utility of intraoperative electrocochleography (ECochG) as a predictive tool for preservation of residual acoustic hearing after cochlear implantation. DATA SOURCES A systematic review employing a multi-database search strategy (Ovid MEDLINE, Embase, EBM Cochrane, and Scopus) was conducted from inception to August 1, 2019. English language studies in humans were included. STUDY SELECTION All articles were independently reviewed by two authors according to Preferred Reporting Items of Systematic Reviews and Meta-analysis (PRISMA) guidelines. Studies without intraoperative ECochG obtained during cochlear implantation were excluded. DATA EXTRACTION Extracted variables included number of patients, ECochG recording technique, success rate of obtaining ECochG potentials, intraoperative changes in ECochG signal, and postoperative hearing preservation outcomes. DATA SYNTHESIS Among 537 eligible articles, 22 met inclusion criteria encompassing 498 unique patients. Ten studies featured extracochlear measurements, eight featured intracochlear measurements, and four featured both. Extracochlear ECochG had an average (SD) recording success rate of 94.9% (12.7%) while intracochlear ECochG had an average (SD) recording success rate of 91.8% (9.8%). One hundred forty five unique patients from six studies had complete intraoperative ECochG data with postoperative behavioral audiometry. After accounting for study-specific definitions of ECochG signal disturbance, worsening changes in intraoperative ECochG signal predicted postoperative hearing loss with limited sensitivity and specificity and notable heterogeneity across studies. CONCLUSIONS Intraoperative ECochG recordings can be obtained in over 90% of patients, but accuracy in predicting postoperative hearing loss remains limited. Standardization of intraoperative ECochG monitoring technique and data interpretation are necessary to more robustly investigate outcomes and refine technique.
Collapse
|
14
|
Band-Limited Chirp-Evoked Compound Action Potential in Guinea Pig: Comprehensive Neural Measure for Cochlear Implantation Monitoring. Ear Hear 2020; 42:142-162. [PMID: 32665481 DOI: 10.1097/aud.0000000000000910] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Patients with severely impaired high-frequency hearing and sufficient residual low-frequency hearing can be provided with a cochlear implant (CI), thereby facilitating ipsilateral electric and acoustic stimulation with established advantages over electric stimulation alone. However, partial or complete hearing loss often occurred after implantation due to, inter alia, acute mechanical trauma to cochlear structures during electrode insertion. Possibilities of intraoperative monitoring using electrocochleography (ECochG) have recently been studied in CI patients, primarily using the ongoing response to low-frequency tone bursts consisting of the cochlear microphonic (CM) and the auditory nerve neurophonic. By contrast, the transient neural response to tone bursts, that is, compound action potential (CAP), was generally less detectable or less sensitive as a monitoring measure, thus falling short of providing useful contribution to electrocochleography analysis. In this study, we investigate using chirps to evoke more robust CAP responses in a limited frequency band by synchronizing neural firing, and thereby improving CAP sensitivity to mechanical trauma in a guinea pig model of cochlear implantation. DESIGN Stimuli were band-limited between 100 Hz and 10 kHz to investigate their frequency range selectivity as a preliminary model for low-frequency hearing. They were constructed by adding a harmonic series either with zero phase delay (click) or by adjusting the phase delay at a rate that is inversely related to a traveling wave delay model (chirp), with three different parameters to examine level-dependent delay compression. The amplitude spectrum was thus identical between stimuli with differences only in phase. In Experiment 1, we compared input-output functions recorded at the round window in normal-hearing guinea pigs and implemented a high-pass noise masking paradigm to infer neural contribution to the CAP. In Experiment 2, guinea pigs were implanted with a custom-built CI electrode using a motorized micromanipulator. Acute mechanical trauma was simulated during the electrode insertion. At each insertion step, CAP and CM responses were measured at the round window for the following stimuli: broad-band click, band-limited click, and band-limited chirps (3 parameters), and tone bursts at frequencies 1, 2, 4, and 8 kHz. RESULTS Chirps compared with the equal-band click showed significantly lower thresholds and steeper slopes of sigmoid-fitted input-output functions. The shorter chirp evoked significantly larger amplitudes than click when compared at equal sensation level. However, the click evoked larger amplitudes than chirps at higher levels and correspondingly achieved larger saturation amplitudes. The results of the high-pass noise masking paradigm suggest that chirps could efficiently synchronize neural firing in their targeted frequency band, while the click recruited more basal fibers outside its limited band. Finally, monitoring sensitivity during electrode insertion, defined as relative amplitude change per unit distance, was higher for chirp-evoked CAP and tone burst-evoked CM, but smaller for CAP responses evoked by clicks or tone bursts. CONCLUSION The chirp was shown to be an efficient stimulus in synchronizing neural firing for a limited frequency band in the guinea pig model. This study provides a proof of principle for using chirp-evoked CAP as a comprehensive neural measure in CI patients with residual hearing.
Collapse
|
15
|
Intracochlear Electrocochleography: Response Patterns During Cochlear Implantation and Hearing Preservation. Ear Hear 2020; 40:833-848. [PMID: 30335669 DOI: 10.1097/aud.0000000000000659] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVES Electrocochleography (ECochG) obtained through a cochlear implant (CI) is increasingly being tested as an intraoperative monitor during implantation with the goal of reducing surgical trauma. Reducing trauma should aid in preserving residual hearing and improve speech perception overall. The purpose of this study was to characterize intracochlear ECochG responses throughout insertion in a range of array types and, when applicable, relate these measures to hearing preservation. The ECochG signal in cochlear implant subjects is complex, consisting of hair cell and neural generators with differing distributions depending on the etiology and history of hearing loss. Consequently, a focus was to observe and characterize response changes as an electrode advances. DESIGN In 36 human subjects, responses to 90 dB nHL tone bursts were recorded both at the round window (RW) and then through the apical contact of the CI as the array advanced into the cochlea. The specific setup used a sterile clip in the surgical field, attached to the ground of the implant with a software-controlled short to the apical contact. The end of the clip was then connected to standard audiometric recording equipment. The stimuli were 500 Hz tone bursts at 90 dB nHL. Audiometry for cases with intended hearing preservation (12/36 subjects) was correlated with intraoperative recordings. RESULTS Successful intracochlear recordings were obtained in 28 subjects. For the eight unsuccessful cases, the clip introduced excessive line noise, which saturated the amplifier. Among the successful subjects, the initial intracochlear response was a median 5.8 dB larger than the response at the RW. Throughout insertion, modiolar arrays showed median response drops after stylet removal while in lateral wall arrays the maximal median response magnitude was typically at the deepest insertion depth. Four main patterns of response magnitude were seen: increases > 5 dB (12/28), steady responses within 5 dB (4/28), drops > 5 dB (from the initial response) at shallow insertion depths (< 15 mm deep, 7/28), or drops > 5 dB occurring at deeper depths (5/28). Hearing preservation, defined as < 80 dB threshold at 250 Hz, was successful in 9/12 subjects. In these subjects, an intracochlear loss of response magnitude afforded a prediction model with poor sensitivity and specificity, which improved when phase, latency, and proportion of neural components was considered. The change in hearing thresholds across cases was significantly correlated with various measures of the absolute magnitudes of response, including RW response, starting response, maximal response, and final responses (p's < 0.05, minimum of 0.0001 for the maximal response, r's > 0.57, maximum of 0.80 for the maximal response). CONCLUSIONS Monitoring the cochlea with intracochlear ECochG during cochlear implantation is feasible, and patterns of response vary by device type. Changes in magnitude alone did not account for hearing preservation rates, but considerations of phase, latency, and neural contribution can help to interpret the changes seen and improve sensitivity and specificity. The correlation between the absolute magnitude obtained either before or during insertion of the ECochG and the hearing threshold changes suggest that cochlear health, which varies by subject, plays an important role.
Collapse
|
16
|
Haumann S, Imsiecke M, Bauernfeind G, Büchner A, Helmstaedter V, Lenarz T, Salcher RB. Monitoring of the Inner Ear Function During and After Cochlear Implant Insertion Using Electrocochleography. Trends Hear 2019; 23:2331216519833567. [PMID: 30909815 PMCID: PMC6435875 DOI: 10.1177/2331216519833567] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
To preserve residual hearing during cochlear implant (CI) surgery, it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring), especially during electrode insertion. A promising method is electrocochleography (ECochG). Within this project, the relations between ongoing responses (ORs), recorded extra- and intracochlearly (EC and IC), and preservation of residual hearing were investigated. Before, during, and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed EC using a cotton wick electrode and after insertion also IC using the CI electrode (MED-EL) and a research software tool. The stimulation was delivered acoustically using low frequency tone bursts. The recordings were conducted in 10 adult CI recipients. The amplitudes of IC ORs were detected to be larger than EC ORs. Intraoperative EC thresholds correlated highly to preoperative audiometric thresholds at 1000 Hz, IC thresholds highly at 250 Hz and 500 Hz. The correlations of both intraoperative ECochG recordings to postoperative pure tone thresholds were low. When measured postoperatively at the same appointments, IC OR thresholds correlated highly to audiometric pure tone thresholds. For all patients, it was possible to record ORs during or directly after electrode insertion. Consequently, we conclude that we did not observe any cases with severe IC trauma. Delayed hearing loss could not be predicted with our method. Nevertheless, intraoperative ECochG recordings are a promising tool to gain further insight into mechanisms impacting residual hearing. Postoperatively recorded IC OR thresholds seem to be a reliable tool for frequency specific hearing threshold estimation.
Collapse
Affiliation(s)
- Sabine Haumann
- 1 Department of Otolaryngology, Hannover Medical School, Germany.,2 Cluster of Excellence Hearing4All, Hannover, Germany
| | - Marina Imsiecke
- 1 Department of Otolaryngology, Hannover Medical School, Germany
| | - Günther Bauernfeind
- 1 Department of Otolaryngology, Hannover Medical School, Germany.,2 Cluster of Excellence Hearing4All, Hannover, Germany
| | - Andreas Büchner
- 1 Department of Otolaryngology, Hannover Medical School, Germany.,2 Cluster of Excellence Hearing4All, Hannover, Germany
| | - Victor Helmstaedter
- 1 Department of Otolaryngology, Hannover Medical School, Germany.,2 Cluster of Excellence Hearing4All, Hannover, Germany
| | - Thomas Lenarz
- 1 Department of Otolaryngology, Hannover Medical School, Germany.,2 Cluster of Excellence Hearing4All, Hannover, Germany
| | - Rolf B Salcher
- 1 Department of Otolaryngology, Hannover Medical School, Germany.,2 Cluster of Excellence Hearing4All, Hannover, Germany
| |
Collapse
|
17
|
Pappa AK, Hutson KA, Scott WC, Wilson JD, Fox KE, Masood MM, Giardina CK, Pulver SH, Grana GD, Askew C, Fitzpatrick DC. Hair cell and neural contributions to the cochlear summating potential. J Neurophysiol 2019; 121:2163-2180. [PMID: 30943095 DOI: 10.1152/jn.00006.2019] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
The cochlear summating potential (SP) to a tone is a baseline shift that persists for the duration of the burst. It is often considered the most enigmatic of cochlear potentials because its magnitude and polarity vary across frequency and level and its origins are uncertain. In this study, we used pharmacology to isolate sources of the SP originating from the gerbil cochlea. Animals either had the full complement of outer and inner hair cells (OHCs and IHCs) and an intact auditory nerve or had systemic treatment with furosemide and kanamycin (FK) to remove the outer hair cells. Responses to tone bursts were recorded from the round window before and after the neurotoxin kainic acid (KA) was applied. IHC responses were then isolated from the post-KA responses in FK animals, neural responses were isolated from the subtraction of post-KA from pre-KA responses in NH animals, and OHC responses were isolated by subtraction of post-KA responses in FK animals from post-KA responses in normal hearing (NH) animals. All three sources contributed to the SP; OHCs with a negative polarity and IHCs and the auditory nerve with positive polarity. Thus the recorded SP in NH animals is a sum of contributions from different sources, contributing to the variety of magnitudes and polarities seen across frequency and intensity. When this information was applied to observations of the SP recorded from the round window in human cochlear implant subjects, a strong neural contribution to the SP was confirmed in humans as well as gerbils. NEW & NOTEWORTHY Of the various potentials produced by the cochlea, the summating potential (SP) is typically described as the most enigmatic. Using combinations of ototoxins and neurotoxins, we show contributions to the SP from the auditory nerve and from inner and outer hair cells, which differ in polarity and vary in size across frequency and level. This complexity of sources helps to explain the enigmatic nature of the SP.
Collapse
Affiliation(s)
- Andrew K Pappa
- Department of Otolaryngology and Head and Neck Surgery, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina
| | - Kendall A Hutson
- Department of Otolaryngology and Head and Neck Surgery, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina
| | - William C Scott
- Department of Otolaryngology and Head and Neck Surgery, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina
| | - J David Wilson
- Department of Otolaryngology and Head and Neck Surgery, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina
| | - Kevin E Fox
- Campbell University School of Osteopathic Medicine, Lillington, North Carolina
| | - Maheer M Masood
- Department of Otolaryngology and Head and Neck Surgery, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina
| | - Christopher K Giardina
- Department of Otolaryngology and Head and Neck Surgery, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina
| | - Stephen H Pulver
- Department of Otolaryngology and Head and Neck Surgery, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina
| | - Gilberto D Grana
- Department of Otolaryngology and Head and Neck Surgery, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina
| | - Charles Askew
- Gene Therapy Center, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina
| | - Douglas C Fitzpatrick
- Department of Otolaryngology and Head and Neck Surgery, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina
| |
Collapse
|
18
|
Response Changes During Insertion of a Cochlear Implant Using Extracochlear Electrocochleography. Ear Hear 2019; 39:1146-1156. [PMID: 29554036 DOI: 10.1097/aud.0000000000000571] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Electrocochleography is increasingly being utilized as an intraoperative monitor of cochlear function during cochlear implantation (CI). Intracochlear recordings from the advancing electrode can be obtained through the device by on-board capabilities. However, such recordings may not be ideal as a monitor because the recording electrode moves in relation to the neural and hair cell generators producing the responses. The purposes of this study were to compare two extracochlear recording locations in terms of signal strength and feasibility as intraoperative monitoring sites and to characterize changes in cochlear physiology during CI insertion. DESIGN In 83 human subjects, responses to 90 dB nHL tone bursts were recorded both at the round window (RW) and then at an extracochlear position-either adjacent to the stapes or on the promontory just superior to the RW. Recording from the fixed, extracochlear position continued during insertion of the CI in 63 cases. RESULTS Before CI insertion, responses to low-frequency tones at the RW were roughly 6 dB larger than when recording at either extracochlear site, but the two extracochlear sites did not differ from one another. During CI insertion, response losses from the promontory or adjacent to the stapes stayed within 5 dB in ≈61% (38/63) of cases, presumably indicating atraumatic insertions. Among responses which dropped more than 5 dB at any time during CI insertion, 12 subjects showed no response recovery, while in 13, the drop was followed by partial or complete response recovery by the end of CI insertion. In cases with recovery, the drop in response occurred relatively early (<15 mm insertion) compared to those where there was no recovery. Changes in response phase during the insertion occurred in some cases; these may indicate a change in the distributions of generators contributing to the response. CONCLUSIONS Monitoring the electrocochleography during CI insertion from an extracochlear site reveals insertions that are potentially atraumatic, show interaction with cochlear structures followed by response recovery, or show interactions such that response losses persist to the end of recording.
Collapse
|
19
|
Changes of Electrocochleographic Responses During Cochlear Implantation Presented at the Annual Meeting of ADANO 2016 in Berlin. Otol Neurotol 2019; 40:e424-e429. [DOI: 10.1097/mao.0000000000001939] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
20
|
Helmstaedter V, Lenarz T, Erfurt P, Kral A, Baumhoff P. The Summating Potential Is a Reliable Marker of Electrode Position in Electrocochleography: Cochlear Implant as a Theragnostic Probe. Ear Hear 2019; 39:687-700. [PMID: 29251689 DOI: 10.1097/aud.0000000000000526] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE For the increasing number of cochlear implantations in subjects with residual hearing, hearing preservation, and thus the prevention of implantation trauma, is crucial. A method for monitoring the intracochlear position of a cochlear implant (CI) and early indication of imminent cochlear trauma would help to assist the surgeon to achieve this goal. The aim of this study was to evaluate the reliability of the different electric components recorded by an intracochlear electrocochleography (ECochG) as markers for the cochleotopic position of a CI. The measurements were made directly from the CI, combining intrasurgical diagnostics with the therapeutical use of the CI, thus, turning the CI into a "theragnostic probe." DESIGN Intracochlear ECochGs were measured in 10 Dunkin Hartley guinea pigs of either sex, with normal auditory brainstem response thresholds. All subjects were fully implanted (4 to 5 mm) with a custom six contact CI. The ECochG was recorded simultaneously from all six contacts with monopolar configuration (retroauricular reference electrode). The gross ECochG signal was filtered off-line to separate three of its main components: compound action potential, cochlear microphonic, and summating potential (SP). Additionally, five cochleae were harvested and histologically processed to access the spatial position of the CI contacts. Both ECochG data and histological reconstructions of the electrode position were fitted with the Greenwood function to verify the reliability of the deduced cochleotopic position of the CI. RESULTS SPs could be used as suitable markers for the frequency position of the recording electrode with an accuracy of ±1/4 octave in the functioning cochlea, verified by histology. Cochlear microphonics showed a dependency on electrode position but were less reliable as positional markers. Compound action potentials were not suitable for CI position information but were sensitive to "cochlear health" (e.g., insertion trauma). CONCLUSIONS SPs directly recorded from the contacts of a CI during surgery can be used to access the intracochlear frequency position of the CI. Using SP monitoring, implantation may be stopped before penetrating functioning cochlear regions. If the technique was similarly effective in humans, it could prevent implantation trauma and increase hearing preservation during CI surgery. Diagnostic hardware and software for recording biological signals with a CI without filter limitations might be a valuable add-on to the portfolios of CI manufacturers.
Collapse
Affiliation(s)
- Victor Helmstaedter
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence "Hearing 4 All" (DFG EXC 1077), Hannover, Germany
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence "Hearing 4 All" (DFG EXC 1077), Hannover, Germany
| | - Peter Erfurt
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Andrej Kral
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence "Hearing 4 All" (DFG EXC 1077), Hannover, Germany.,Department of Experimental Otology & Institute of AudioNeuroTechnology (VIANNA), Hannover, Germany
| | - Peter Baumhoff
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany.,Department of Experimental Otology & Institute of AudioNeuroTechnology (VIANNA), Hannover, Germany
| |
Collapse
|
21
|
Dalbert A, Pfiffner F, Hoesli M, Koka K, Veraguth D, Roosli C, Huber A. Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography. Front Neurosci 2018; 12:18. [PMID: 29434534 PMCID: PMC5790789 DOI: 10.3389/fnins.2018.00018] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Accepted: 01/10/2018] [Indexed: 11/24/2022] Open
Abstract
Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological changes during cochlear implantation. Extracochlear ECoG recordings were conducted through a needle electrode placed on the promontory; for intracochlear ECoG recordings, the most apical contact of the cochlear implant (CI) electrode itself was used as the recording electrode. Tone bursts at 250, 500, 750, and 1000 Hz were used as low-frequency acoustic stimuli and clicks as high-frequency acoustic stimuli. Changes of extracochlear ECoG recordings after full insertion of the CI electrode were correlated with pure-tone audiometric findings 4 weeks after surgery. Results: Changes in extracochlear ECoG recordings correlated with postoperative hearing change (r = −0.44, p = 0.055, n = 20). Mean hearing loss in subjects without decrease or loss of extracochlear ECoG signals was 12 dB, compared to a mean hearing loss of 22 dB in subjects with a detectable decrease or a loss of ECoG signals (p = 0.0058, n = 51). In extracochlear ECoG recordings, a mean increase of the ECoG signal of 4.4 dB occurred after opening the cochlea. If a decrease of ECoG signals occurred during insertion of the CI electrode, the decrease was detectable during the second half of the insertion. Conclusion: ECoG recordings allow detection of electrophysiological changes in the cochlea during cochlear implantation. Decrease of extracochlear ECoG recordings during surgery has a significant correlation with hearing loss 4 weeks after surgery. Trauma to cochlear structures seems to occur during the final phase of the CI electrode insertion. Baseline recordings for extracochlear ECoG recordings should be conducted after opening the cochlea. ECoG responses can be recorded from an intracochlear site using the CI electrode as recording electrode. This technique may prove useful for monitoring cochlear trauma intraoperatively in the future.
Collapse
Affiliation(s)
- Adrian Dalbert
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| | - Flurin Pfiffner
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| | - Marco Hoesli
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| | - Kanthaiah Koka
- Department of Research and Technology, Advanced Bionics LLC, Valencia, CA, United States
| | - Dorothe Veraguth
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| | - Christof Roosli
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| | - Alexander Huber
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| |
Collapse
|
22
|
Dalbert A, Pfiffner F, Hoesli M, Koka K, Veraguth D, Roosli C, Huber A. Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography. Front Neurosci 2018. [PMID: 29434534 DOI: 10.3389/fnins.2018.00018/bibtex] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/24/2023] Open
Abstract
Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological changes during cochlear implantation. Extracochlear ECoG recordings were conducted through a needle electrode placed on the promontory; for intracochlear ECoG recordings, the most apical contact of the cochlear implant (CI) electrode itself was used as the recording electrode. Tone bursts at 250, 500, 750, and 1000 Hz were used as low-frequency acoustic stimuli and clicks as high-frequency acoustic stimuli. Changes of extracochlear ECoG recordings after full insertion of the CI electrode were correlated with pure-tone audiometric findings 4 weeks after surgery. Results: Changes in extracochlear ECoG recordings correlated with postoperative hearing change (r = -0.44, p = 0.055, n = 20). Mean hearing loss in subjects without decrease or loss of extracochlear ECoG signals was 12 dB, compared to a mean hearing loss of 22 dB in subjects with a detectable decrease or a loss of ECoG signals (p = 0.0058, n = 51). In extracochlear ECoG recordings, a mean increase of the ECoG signal of 4.4 dB occurred after opening the cochlea. If a decrease of ECoG signals occurred during insertion of the CI electrode, the decrease was detectable during the second half of the insertion. Conclusion: ECoG recordings allow detection of electrophysiological changes in the cochlea during cochlear implantation. Decrease of extracochlear ECoG recordings during surgery has a significant correlation with hearing loss 4 weeks after surgery. Trauma to cochlear structures seems to occur during the final phase of the CI electrode insertion. Baseline recordings for extracochlear ECoG recordings should be conducted after opening the cochlea. ECoG responses can be recorded from an intracochlear site using the CI electrode as recording electrode. This technique may prove useful for monitoring cochlear trauma intraoperatively in the future.
Collapse
Affiliation(s)
- Adrian Dalbert
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| | - Flurin Pfiffner
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| | - Marco Hoesli
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| | - Kanthaiah Koka
- Department of Research and Technology, Advanced Bionics LLC, Valencia, CA, United States
| | - Dorothe Veraguth
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| | - Christof Roosli
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| | - Alexander Huber
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Zurich, University Hospital of Zurich, Zurich, Switzerland
| |
Collapse
|
23
|
Fontenot TE, Giardina CK, Fitzpatrick DC. A Model-Based Approach for Separating the Cochlear Microphonic from the Auditory Nerve Neurophonic in the Ongoing Response Using Electrocochleography. Front Neurosci 2017; 11:592. [PMID: 29123468 PMCID: PMC5662900 DOI: 10.3389/fnins.2017.00592] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Accepted: 10/09/2017] [Indexed: 12/02/2022] Open
Abstract
Electrocochleography (ECochG) is a potential clinically valuable technique for predicting speech perception outcomes in cochlear implant (CI) recipients, among other uses. Current analysis is limited by an inability to quantify hair cell and neural contributions which are mixed in the ongoing part of the response to low frequency tones. Here, we used a model based on source properties to account for recorded waveform shapes and to separate the combined signal into its components. The model for the cochlear microphonic (CM) was a sinusoid with parameters for independent saturation of the peaks and the troughs of the responses. The model for the auditory nerve neurophonic (ANN) was the convolution of a unit potential and population cycle histogram with a parameter for spread of excitation. Phases of the ANN and CM were additional parameters. The average cycle from the ongoing response was the input, and adaptive fitting identified CM and ANN parameters that best reproduced the waveform shape. Test datasets were responses recorded from the round windows of CI recipients, from the round window of gerbils before and after application of neurotoxins, and with simulated signals where each parameter could be manipulated in isolation. Waveforms recorded from 284 CI recipients had a variety of morphologies that the model fit with an average r2 of 0.97 ± 0.058 (standard deviation). With simulated signals, small systematic differences between outputs and inputs were seen with some variable combinations, but in general there were limited interactions among the parameters. In gerbils, the CM reported was relatively unaffected by the neurotoxins. In contrast, the ANN was strongly reduced and the reduction was limited to frequencies of 1,000 Hz and lower, consistent with the range of strong neural phase-locking. Across human CI subjects, the ANN contribution was variable, ranging from nearly none to larger than the CM. Development of this model could provide a means to isolate hair cell and neural activity that are mixed in the ongoing response to low-frequency tones. This tool can help characterize the residual physiology across CI subjects, and can be useful in other clinical settings where a description of the cochlear physiology is desirable.
Collapse
Affiliation(s)
- Tatyana E Fontenot
- Otolaryngology-Head and Neck Surgery, University of North Carolina, Chapel Hill, NC, United States
| | | | - Douglas C Fitzpatrick
- Otolaryngology-Head and Neck Surgery, University of North Carolina, Chapel Hill, NC, United States.,School of Medicine, University of North Carolina, Chapel Hill, NC, United States
| |
Collapse
|
24
|
Dalbert A, Huber A, Veraguth D, Roosli C, Pfiffner F. Assessment of Cochlear Trauma During Cochlear Implantation Using Electrocochleography and Cone Beam Computed Tomography. Otol Neurotol 2017; 37:446-53. [PMID: 26945317 DOI: 10.1097/mao.0000000000000998] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To assess cochlear trauma during cochlear implantation by electrocochleography (ECoG) and cone beam computed tomography (CBCT) and to correlate intraoperative cochlear trauma with postoperative loss of residual hearing. METHODS ECoG recordings to tone bursts at 250, 500, 750, and 1000 Hz and click stimuli were recorded before and after insertion of the cochlear implant electrode array, using an extracochlear recording electrode. CBCTs were conducted within 6 weeks after surgery. Changes of intraoperative ECoG recordings and CBCT findings were correlated with postoperative threshold shifts in pure-tone audiograms. RESULTS Fourteen subjects were included. In three subjects a decrease of low-frequency ECoG responses at 250, 500, 750, and 1000 Hz occurred after insertion of the electrode array. This was associated with no or minimal residual hearing 4 weeks after surgery. ECoG responses to click stimuli were present in six subjects and showed a decrease after insertion of the electrode array in three. This was associated with a mean hearing loss of 21 dB in postoperative pure-tone audiograms. Scalar dislocation of the electrode array was assumed in one subject because of CBCT findings and correlated with a decrease of low-frequency ECoG responses and a complete loss of residual hearing. CONCLUSION Hearing loss of ≤11 dB is not associated with detectable decrease in ECoG recordings during cochlear implantation. However, in a majority of patients with threshold shifts of >11 dB or complete hearing loss, an intraoperative decrease of high- or low-frequency ECoG signals occurs, suggesting acute cochlear trauma.
Collapse
Affiliation(s)
- Adrian Dalbert
- University of Zurich and Department of Otorhinolaryngology-Head and Neck Surgery, University Hospital Zurich, Zurich, Switzerland
| | | | | | | | | |
Collapse
|
25
|
Correlation of Electrophysiological Properties and Hearing Preservation in Cochlear Implant Patients. Otol Neurotol 2016; 36:1172-80. [PMID: 25839980 DOI: 10.1097/mao.0000000000000768] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To monitor changes in cochlear function during cochlear implantation using electrocochleography (ECoG) and to correlate changes to postoperative hearing preservation. METHODS ECoG responses to acoustic stimuli of 250, 500, and 1000 Hz were recorded during cochlear implantation. The recording electrode was placed on the promontory and stabilized to fix the position during cochlear implantation. Baseline recordings were obtained after completion of the posterior tympanotomy. Changes of the ongoing ECoG response at suprathreshold intensities were analyzed after full insertion of the cochlear implant electrode array. Audiometric tests were conducted before and 4 weeks after surgery and correlated with electrophysiological findings. RESULTS Ninety-five percent (18/19) of cochlear implant subjects had measurable ECoG responses. Under unchanged conditions, recordings showed a high repeatability without significant differences between 2 recordings (p ≤ 0.01). Ninety-four percent (17/18) of subjects showed no relevant changes in ECoG recordings after insertion of the cochlear implant electrode array. One subject showed decreases in responses at all frequencies indicative of cochlear trauma. This was associated with a complete hearing loss 4 weeks after surgery compared with mean presurgical low-frequency hearing of 78 dB HL. CONCLUSION Extracochlear ECoG is a reliable tool to assess cochlear function during cochlear implantation. Moderate threshold shifts could be caused by postoperative mechanisms or minor cochlear trauma. Detectable changes in extracochlear ECoG recordings, indicating gross cochlear trauma, are probably predictive of complete loss of residual acoustic hearing.
Collapse
|
26
|
Adunka OF, Giardina CK, Formeister EJ, Choudhury B, Buchman CA, Fitzpatrick DC. Round window electrocochleography before and after cochlear implant electrode insertion. Laryngoscope 2015; 126:1193-200. [PMID: 26360623 DOI: 10.1002/lary.25602] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/22/2015] [Indexed: 11/09/2022]
Abstract
OBJECTIVE/HYPOTHESIS Previous reports have documented the feasibility of utilizing electrocochleographic (ECoG) responses to acoustic signals to assess trauma caused during cochlear implantation. The hypothesis is that intraoperative round window ECoG before and after electrode insertion will help predict postoperative hearing preservation outcomes in cochlear implant recipients. STUDY DESIGN Prospective cohort study. METHODS Intraoperative round window ECoG responses were collected from 31 cochlear implant recipients (14 children and 17 adults) immediately prior to and just after electrode insertion. Hearing preservation was determined by postoperative changes in behavioral thresholds. RESULTS On average, the postinsertion response was smaller than the preinsertion response by an average of 4 dB across frequencies. However, in some cases (12 of 31) the response increased after insertion. The subsequent hearing loss was greater than the acute loss in the ECoG, averaging 22 dB across the same frequency range (250-1,000 Hz). There was no correlation between the change in the ECoG response and the corresponding change in audiometric threshold. CONCLUSIONS Intraoperative ECoG is a sensitive method for detecting electrophysiologic changes during implantation but had limited prognostic value regarding hearing preservation in the current conventional cochlear implant patient population where hearing preservation was not intended. LEVEL OF EVIDENCE 2b Laryngoscope, 126:1193-1200, 2016.
Collapse
Affiliation(s)
- Oliver F Adunka
- Department of Otolaryngology-Head & Neck Surgery, the Ohio State University, Columbus, Ohio, U.S.A.,Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Christopher K Giardina
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Eric J Formeister
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Baishakhi Choudhury
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Craig A Buchman
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Douglas C Fitzpatrick
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| |
Collapse
|
27
|
Abstract
OBJECTIVE Electrophysiologic responses to acoustic stimuli are present in nearly all cochlear implant recipients when measured at the round window (RW). Intracochlear recording sites might provide an even larger signal and improve the sensitivity and the potential clinical utility of electrocochleography (ECoG). Thus, the goal of this study is to compare RW to intracochlear recording sites and to determine if such recordings can be used to monitor cochlear function during insertion of a cochlear implant. METHODS Intraoperative ECoG recordings were obtained in subjects receiving a cochlear implant from the RW and from just inside scala tympani (n = 26). Stimuli were tones at high levels (80-100 dB HL). Further recordings were obtained during insertions of a temporary lateral cochlear wall electrode (n = 8). Response magnitudes were determined as the sum of the first and second harmonics amplitudes. RESULTS All subjects had measurable extracochlear responses at the RW. Twenty cases (78%) showed a larger intracochlear response, compared with three (11%) that had a smaller response and three that were unchanged. On average, signal amplitudes increased with increasing electrode insertion depths, with the largest increase between 15 and 20 mm from the RW. CONCLUSION ECoG to acoustic stimuli via an intracochlear electrode is feasible in standard cochlear implant recipients. The increased signal can improve the speed and efficiency of data collection. The growth of response magnitudes with deeper intrascalar electrode positions could be explained by closer proximity or favorable geometry with respect to residual apical signal generators. Reductions in magnitude may represent unfavorable geometry or cochlear trauma.
Collapse
|
28
|
Electrophysiologic consequences of flexible electrode insertions in gerbils with noise-induced hearing loss. Otol Neurotol 2014; 35:519-25. [PMID: 23988997 DOI: 10.1097/mao.0b013e31829bdf2b] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
HYPOTHESIS Flexible electrode interaction with intracochlear structures in a noise-damaged region of the cochlea can lead to measureable electrophysiologic changes. BACKGROUND An emerging goal in cochlear implantation is preservation of residual hearing subsequently allowing for combined electric and acoustic stimulation (EAS). However, residual hearing is at least partially lost in most patients as a result of electrode insertion. A gerbil model was used to examine changes to acoustically evoked cochlear potentials during simulated cochlear implantation. METHODS Gerbils were partially deafened by noise exposure to mimic residual hearing in human cochlear implant candidates. After 1 month, round window and intracochlear recordings during flexible electrode insertion were made in response to 1 kHz tone burst stimuli at 80 dB SPL. After the insertion, the cochleas were histologically examined for hair cell loss because of the noise exposure and trauma because of the electrode insertion. RESULTS Anatomic damage from the flexible electrode was not observable in most cases. However, insertions caused response declines that were, on average, greater than the controls, although some losses were similar to the controls. The CM was more sensitive than the CAP for detecting cochlear disturbance. CONCLUSION Because response reductions occurred in the absence of anatomic damage, disturbances in the fluid at the base appear to affect responses from the apex. The losses were less than in previous experiments where the basilar membrane was penetrated.
Collapse
|
29
|
|
30
|
Abstract
OBJECTIVES Cochlear implants (CI) perform especially well if residual acoustic hearing is retained and combined with the CI in the same ear (also termed hybrid or electric-acoustic stimulation). However, in most CI patients, residual hearing is at least partially compromised during surgery, and in some it is lost completely. At present, clinicians have no feedback on the functional status of the cochlea during electrode insertion. Development of an intraoperative physiological recording algorithm during electrode insertion could serve to detect reversible cochlear trauma and optimal placement relative to surviving hair cells. In this report, an animal model was used to assist in determining physiological markers for these conditions using a flexible electrode similar to human surgery. DESIGN The animal model was the normal-hearing gerbil. The flexible electrodes had 1 to 2 platinum-iridium contacts embedded in a 200 µm diameter silastic carrier. As control experiments some insertions were also made with much smaller (50 µm diameter) rigid electrodes. In either case, the electrode was positioned at or just inside the round window membrane and subsequently advanced into the scala tympani longitudinally in 50 to 100 µm increments. After each advancement, acoustic stimulation was used to elicit a cochlear microphonic (CM) and compound action potential (CAP). Stimuli were suprathreshold tone bursts of 1 to 16 kHz in octave steps with 2 msec rise and fall times and a 10 msec plateau. Anatomical integrity of the cochlea was subsequently assessed using a whole-mount preparation. RESULTS In contrast with the CAP, which was relatively stable during insertion, the CM showed a variety of changes related to electrode movement. To tone bursts of 1 to 8 kHz the CM typically remained stable or increased during the insertion before contact with cochlear structures. After contact, the potentials often dropped dramatically. The CM to 16 kHz was the most variable; in some cases it increased but in other cases it decreased early in the insertion and later showed large and abrupt increases. In some instances, this pattern was seen to progressively lower frequencies as well. Histological analysis and the gerbil frequency map indicate that electrode travel was limited to the basal turn (~4 mm from the hook) and did not intrude into the characteristic frequency regions of most frequencies used. CONCLUSIONS First, the CM provides a more sensitive indication of cochlear trauma than does the CAP. Second, stable or steady increases in the CM are a physiological marker for unimpeded travel through the scala tympani as the electrode approaches responding hair cells. Third, abrupt reductions in the CM across frequency are a physiological marker of contact with cochlear structures. Fourth, abrupt increases after a decline, which occurred primarily to 16 kHz but to a lesser degree to other frequencies as well, are a physiological marker for a release from contact. The interpretation is that as the tip of the electrode bends the shaft can move in the mediolateral dimension, sometimes contacting the basilar membrane and sometimes not. Overall, the results indicate that recordings during cochlear implantations can provide valuable feedback to the surgeon regarding electrode position and the integrity of surviving hair cells.
Collapse
|
31
|
Ahmad FI, Choudhury B, De Mason CE, Adunka OF, Finley CC, Fitzpatrick DC. Detection of intracochlear damage during cochlear implant electrode insertion using extracochlear measurements in the gerbil. Laryngoscope 2012; 122:636-44. [PMID: 22252968 DOI: 10.1002/lary.22488] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2011] [Revised: 10/20/2011] [Accepted: 10/26/2011] [Indexed: 11/08/2022]
Abstract
OBJECTIVES/HYPOTHESIS An intraoperative monitoring algorithm during cochlear implant electrode insertion could be used to detect trauma and guide electrode placement relative to surviving hair cells. The aim of this report was to assess the feasibility of using extracochlear recording sites to monitor acoustically evoked responses from surviving hair cells and neural elements during implantation in an animal model. STUDY DESIGN Animal experiments. METHODS The normal-hearing gerbil was used. Two recording methods, one using a lock-in amplifier and another using Fourier analysis of recorded signals, were used to obtain frequency-specific information about the responses to tones. Amplitude and threshold determinations were made at the round window and at three extracochlear sites. To induce intracochlear damage, a platinum-iridium wire was inserted through the round window. The wire was advanced, and changes in the potentials were correlated with cochlear contact. Anatomic integrity was assessed using cochlea whole mount preparations. RESULTS In general, the lock-in amplifier showed greater sensitivity and lower thresholds at higher frequencies relative to the Fourier method. Also, the lock-in amplifier was more resistant to masking effects. Both systems were able to detect loss of cochlear potentials secondary to intracochlear trauma. Histologic damage was seen in all cases and corresponded to electrophysiologic changes. CONCLUSIONS Impact of electrodes on cochlear structures affecting cochlear performance could be detected from several extracochlear sites. The lock-in amplifier demonstrated greater sensitivity and resistance to noise when compared to the fast Fourier transform recording paradigm. The latter showed greater flexibility of detecting and separating hair cell and neural potentials.
Collapse
Affiliation(s)
- Faisal I Ahmad
- Department of Otolargynology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-7070, USA
| | | | | | | | | | | |
Collapse
|
32
|
Abstract
OBJECTIVE The goal of the overall project is to develop knowledge about cochlear physiology during cochlear implantation and develop procedures for assessing its status during hearing preservation surgery. As a step toward this goal, for this study, we established an animal model of sloping high frequency sensorineural hearing loss that mimics the hearing condition of candidates for combined electric-acoustic stimulation. METHODS Mongolian gerbils were exposed to band-pass noise using various cutoff frequencies, intensities, exposure times, and survival times. Hearing loss was assessed in far-field recording using preexposure and postexposure auditory brainstem responses (ABRs), and in acute, near-field recordings of the cochlear microphonic and compound action potential from an electrode on the round window. Anatomic loss of hair cells was assessed from dissections. RESULTS Postexposure ABRs and near-field recordings from the round window revealed sensorineural hearing loss that varied with the overall noise exposure. Loss of hair cells ranged from relatively sparse to large areas of complete absence depending on the noise exposure. Cases with high intensity (120 dB SPL) and long exposure times (3 h) showed sloping patterns of hearing loss with profound high-frequency loss and mild-to-moderate low-frequency loss. These cases showed complete loss of hair cells in the basal cochlea and preserved hair cells in the apical cochlea. The frequencies comprising the slope in the ABRs and the location of the transition zone between preserved and lost hair cells varied according to the cutoff frequency used. CONCLUSION We were able to reliably induce sensorineural hearing loss and loss of hair cells in the gerbil that is comparable to candidates for hearing preservation surgery. This model can be used to evaluate the effects of electrode introduction in a system with a hearing condition similar to that in cases of hearing preservation operations.
Collapse
|
33
|
Campbell AP, Suberman TA, Buchman CA, Fitzpatrick DC, Adunka OF. Correlation of early auditory potentials and intracochlear electrode insertion properties: an animal model featuring near real-time monitoring. Otol Neurotol 2011; 31:1391-8. [PMID: 20856155 DOI: 10.1097/mao.0b013e3181f6c899] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The goal of this work was to assess electrophysiologic response changes to acoustic stimuli as an intracochlear electrode impacted cochlear structures in an animal model of hearing preservation cochlear implantation. The ultimate goal is to develop efficient procedures for assessing the status of cochlear physiology for intraoperative use. METHODS Sixteen gerbils and 18 ears were tested. A rigid electrode was inserted through a basal turn cochleostomy and directed toward the basilar membrane/osseous spiral lamina complex. We recorded acoustically evoked early auditory potentials including cochlear microphonics (CMs) and compound action potentials (CAPs) to a short stimulation sequence consisting of one stimulus frequency and intensity as the electrode was advanced. A microendoscope was used to visualize the electrode insertion progress and to identify the site of electrode impact. After each experiment, the site of intracochlear trauma was confirmed using whole mount preparations. RESULTS Electrophysiologic changes correlated well with the degree and location of trauma. We observed four distinct patterns. In addition, the endoscope in conjunction with the short recording sequence allowed for the detection of response changes that were reversible when the electrode was retracted. These cases were associated with less than full-thickness damage on histology. CONCLUSION The short recording sequence to obtain acoustically evoked intracochlear potentials and the microendoscope allowed us to detect various levels of cochlear trauma including minor and reversible damage. Recordings of this type are potentially available using current implant technology. Future improvements in the measurements can be expected to improve the efficiency of the recording paradigm to produce a clinically useful tool.
Collapse
Affiliation(s)
- Adam P Campbell
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-7070, USA
| | | | | | | | | |
Collapse
|
34
|
Campbell AP, Suberman TA, Buchman CA, Fitzpatrick DC, Adunka OF. Flexible cochlear microendoscopy in the gerbil. Laryngoscope 2010; 120:1619-24. [PMID: 20564668 DOI: 10.1002/lary.20979] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVES/HYPOTHESIS To validate the scientific utility of flexible cochlear microendoscopy in the gerbil. This model is currently being developed to study the effects of intracochlear electrode positioning on functional parameters. STUDY DESIGN Animal experiments. METHODS A flexible fiberoptic microendoscope featuring a light channel and an outer diameter of 0.4 mm was specially modified to allow intracochlear visualization. Specifically, the focus distance was reduced to 1 mm and the optical properties were modified so that visualization was adequate when submerged in perilymphatic fluid. This endoscope was used to view intracochlear contents and monitor the progress of electrode insertions in 11 gerbils. The endoscopic data estimating the site of damage were compared to postmortem microdissections. RESULTS The endoscope allowed for adequate visualization of intracochlear content in all animals. The site of electrode contact seen in the endoscope was confirmed in the microdissected cochleae in 10 of 11 cases, indicating the endoscope's ability to correctly identify the site of intracochlear trauma in this animal model. CONCLUSIONS The current report demonstrates the feasibility of intracochlear microendoscopy in an animal model of hearing preservation cochlear implantation.
Collapse
Affiliation(s)
- Adam P Campbell
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | | | | | | | | |
Collapse
|