1
|
Lamy J, Gonzales RA, Xiang J, Seemann F, Huber S, Steele J, Wieben O, Heiberg E, Peters DC. Tricuspid valve flow measurement using a deep learning framework for automated valve-tracking 2D phase contrast. Magn Reson Med 2024; 92:1838-1850. [PMID: 38817154 PMCID: PMC11341256 DOI: 10.1002/mrm.30163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 04/17/2024] [Accepted: 05/06/2024] [Indexed: 06/01/2024]
Abstract
PURPOSE Tricuspid valve flow velocities are challenging to measure with cardiovascular MR, as the rapidly moving valvular plane prohibits direct flow evaluation, but they are vitally important to diastolic function evaluation. We developed an automated valve-tracking 2D method for measuring flow through the dynamic tricuspid valve. METHODS Nine healthy subjects and 2 patients were imaged. The approach uses a previously trained deep learning network, TVnet, to automatically track the tricuspid valve plane from long-axis cine images. Subsequently, the tracking information is used to acquire 2D phase contrast (PC) with a dynamic (moving) acquisition plane that tracks the valve. Direct diastolic net flows evaluated from the dynamic PC sequence were compared with flows from 2D-PC scans acquired in a static slice localized at the end-systolic valve position, and also ventricular stroke volumes (SVs) using both planimetry and 2D PC of the great vessels. RESULTS The mean tricuspid valve systolic excursion was 17.8 ± 2.5 mm. The 2D valve-tracking PC net diastolic flow showed excellent correlation with SV by right-ventricle planimetry (bias ± 1.96 SD = -0.2 ± 10.4 mL, intraclass correlation coefficient [ICC] = 0.92) and aortic PC (-1.0 ± 13.8 mL, ICC = 0.87). In comparison, static tricuspid valve 2D PC also showed a strong correlation but had greater bias (p = 0.01) versus the right-ventricle SV (10.6 ± 16.1 mL, ICC = 0.61). In most (8 of 9) healthy subjects, trace regurgitation was measured at begin-systole. In one patient, valve-tracking PC displayed a high-velocity jet (380 cm/s) with maximal velocity agreeing with echocardiography. CONCLUSION Automated valve-tracking 2D PC is a feasible route toward evaluation of tricuspid regurgitant velocities, potentially solving a major clinical challenge.
Collapse
Affiliation(s)
- Jérôme Lamy
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, LIB, Paris, France
| | - Ricardo A Gonzales
- Oxford Center for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Jie Xiang
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
| | - Felicia Seemann
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Steffen Huber
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
| | - Jeremy Steele
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
| | - Oliver Wieben
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| | - Einar Heiberg
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Dana C Peters
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
| |
Collapse
|
2
|
Mangini F, Scarcia M, Biederman RWW, Calbi R, Spinelli F, Casavecchia G, Brunetti ND, Gravina M, Fiore C, Suma S, Milo M, Turchetti C, Pesce E, Caramia R, Lombardi F, Grimaldi M. Cardiac magnetic resonance imaging in the evaluation and management of mitral valve prolapse - a comprehensive review. Echocardiography 2024; 41:e15894. [PMID: 39078395 DOI: 10.1111/echo.15894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Revised: 07/01/2024] [Accepted: 07/05/2024] [Indexed: 07/31/2024] Open
Abstract
Mitral valve prolapse is a common valve disorder that usually has a benign prognosis unless there is significant regurgitation or LV impairment. However, a subset of patients are at an increased risk of ventricular arrhythmias and sudden cardiac death, which has led to the recognition of "arrhythmic mitral valve prolapse" as a clinical entity. Emerging risk factors include mitral annular disjunction and myocardial fibrosis. While echocardiography remains the primary method of evaluation, cardiac magnetic resonance has become crucial in managing this condition. Cine magnetic resonance sequences provide accurate characterization of prolapse and annular disjunction, assessment of ventricular volumes and function, identification of early dysfunction and remodeling, and quantitative assessment of mitral regurgitation when integrated with flow imaging. However, the unique strength of magnetic resonance lies in its ability to identify tissue changes. T1 mapping sequences identify diffuse fibrosis, in turn related to early ventricular dysfunction and remodeling. Late gadolinium enhancement sequences detect replacement fibrosis, an independent risk factor for ventricular arrhythmias and sudden cardiac death. There are consensus documents and reviews on the use of cardiac magnetic resonance specifically in arrhythmic mitral valve prolapse. However, in this article, we propose an algorithm for the broader use of cardiac magnetic resonance in managing this condition in various scenarios. Future advancements may involve implementing techniques for tissue characterization and flow analysis, such as 4D flow imaging, to identify patients with ventricular dysfunction and remodeling, increased arrhythmic risk, and more accurate grading of mitral regurgitation, ultimately benefiting patient selection for surgical therapy.
Collapse
Affiliation(s)
- Francesco Mangini
- Department of Cardiology, Ospedale Regionale "Miulli", Acquaviva delle Fonti, BA, Italy
| | - Maria Scarcia
- Department of Cardiology, Ospedale Regionale "Miulli", Acquaviva delle Fonti, BA, Italy
| | - Robert W W Biederman
- Cardiology Department, Roper St Francis Healthcare, Charleston, South Carolina, USA
| | - Roberto Calbi
- Department of Cardiology, Ospedale Regionale "Miulli", Acquaviva delle Fonti, BA, Italy
| | - Francesco Spinelli
- Department of Cardiology, Ospedale Regionale "Miulli", Acquaviva delle Fonti, BA, Italy
| | | | | | - Matteo Gravina
- Radiology Department, University of Foggia, Foggia, Italy
| | - Corrado Fiore
- Department of Cardiology, Citta di Lecce Hospital, Novoli (Lecce), Puglia, Italy
| | - Sergio Suma
- Department of Cardiology, Azienda Ospedaliero Universitaria di Parma, Parma, Italy
| | - Maria Milo
- Department of Cardiology, Ospedale "Di Summa - Perrino," ASL Br, Brindisi, Italy
| | | | - Ernesto Pesce
- Madonna della Bruna Outpatients Clinic, Matera, Italy
| | - Remo Caramia
- Department of Anesthesiology, Ospedale "Camberlingo," ASL Br, Francavilla Fontana, Italy
| | - Francesca Lombardi
- Department of Cardiovascular Sciences, Università Cattolica del Sacro Cuore, Milano, Lombardia, Italy
| | - Massimo Grimaldi
- Department of Cardiology, Ospedale Regionale "Miulli", Acquaviva delle Fonti, BA, Italy
| |
Collapse
|
3
|
In de Braekt T, Aben JP, Maussen M, van den Bosch HCM, Houthuizen P, Roest AAW, van den Boogaard PJ, Lamb HJ, Westenberg JJM. Fully Automated Valve Segmentation for Blood Flow Assessment From 4D Flow MRI Including Automated Cardiac Valve Tracking and Transvalvular Velocity Mapping. J Magn Reson Imaging 2024. [PMID: 38558490 DOI: 10.1002/jmri.29370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 04/04/2024] Open
Abstract
BACKGROUND Automated 4D flow MRI valvular flow quantification without time-consuming manual segmentation might improve workflow. PURPOSE Compare automated valve segmentation (AS) to manual (MS), and manually corrected automated segmentation (AMS), in corrected atrioventricular septum defect (c-AVSD) patients and healthy volunteers, for assessing net forward volume (NFV) and regurgitation fraction (RF). STUDY TYPE Retrospective. POPULATION 27 c-AVSD patients (median, 23 years; interquartile range, 16-31 years) and 24 healthy volunteers (25 years; 12.5-36.5 years). FIELD STRENGTH/SEQUENCE Whole-heart 4D flow MRI and cine steady-state free precession at 3T. ASSESSMENT After automatic valve tracking, valve annuli were segmented on time-resolved reformatted trans-valvular velocity images by AS, MS, and AMS. NFV was calculated for all valves, and RF for right and left atrioventricular valves (RAVV and LAVV). NFV variation (standard deviation divided by mean NFV) and NFV differences (NFV difference of a valve vs. mean NFV of other valves) expressed internal NFV consistency. STATISTICAL TESTS Comparisons between methods were assessed by Wilcoxon signed-rank tests, and intra/interobserver variability by intraclass correlation coefficients (ICCs). P < 0.05 was considered statistically significant, with multiple testing correction. RESULTS AMS mean analysis time was significantly shorter compared with MS (5.3 ± 1.6 minutes vs. 9.1 ± 2.5 minutes). MS NFV variation (6.0%) was significantly smaller compared with AMS (6.3%), and AS (8.2%). Median NFV difference of RAVV, LAVV, PV, and AoV between segmentation methods ranged from -0.7-1.0 mL, -0.5-2.8 mL, -1.1-3.6 mL, and - 3.1--2.1 mL, respectively. Median RAVV and LAVV RF, between 7.1%-7.5% and 3.8%-4.3%, respectively, were not significantly different between methods. Intraobserver/interobserver agreement for AMS and MS was strong-to-excellent for NFV and RF (ICC ≥0.88). DATA CONCLUSION MS demonstrates strongest internal consistency, followed closely by AMS, and AS. Automated segmentation, with or without manual correction, can be considered for 4D flow MRI valvular flow quantification. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY: Stage 3.
Collapse
Affiliation(s)
- Thomas In de Braekt
- Department of Radiology, Catharina Hospital, Eindhoven, the Netherlands
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | | | - Marc Maussen
- Pie Medical Imaging BV, Maastricht, the Netherlands
| | | | - Patrick Houthuizen
- Department of Cardiology, Catharina Hospital, Eindhoven, the Netherlands
| | - Arno A W Roest
- Department of Pediatric Cardiology, Leiden University Medical Center, Leiden, the Netherlands
| | | | - Hildo J Lamb
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Jos J M Westenberg
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
4
|
Oh Y, Heo CM, Gwoo S, Huh H, Park S, Heo W. Effect of flow reduction surgery in a patient with high flow arteriovenous fistula with aortic dissection using 4D flow magnetic resonance imaging: A case report. J Vasc Access 2023:11297298231209778. [PMID: 38142278 DOI: 10.1177/11297298231209778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2023] Open
Abstract
This study aimed to investigate cardiovascular function in a patient with high-flow arteriovenous fistula (AVF) who underwent aortic dissection (AD) using four-dimensional (4D) flow magnetic resonance imaging (MRI) as well as analyze the effect of flow reduction surgery on AD. On March 12, 2017, a 60-year-old woman underwent emergency surgery for AD. After that, she experienced acute kidney injury, and hemodialysis was initiated. On April 24, 2017, a left brachiocephalic arteriovenous fistula (AVF) was created to facilitate her dialysis. However, after 5 years, the patient presented with a high-flow AVF, and a flow reduction surgery was performed on March 11, 2022. To evaluate the procedure's effectiveness, we measured the changes in left ventricular (LV) function and blood flow in the aorta and vascular access before and after surgery using 4D flow MRI. Notable changes were observed in LV function, blood flow in the aorta before and after the surgery, and maximum velocity and flow volume after surgery. During the 6-month follow-up after the surgery, the maximum velocity and flow volume in the aorta and vascular access were reduced; also, indicators such as LV volume, cardiac output, cardiac index, and LV mass were improved. In patients with high-flow AVF, flow reduction surgery should be considered as it may improve LV function and reduce the risk of AD recurrence by lowering the flow volume of the aorta.
Collapse
Affiliation(s)
- Yeongrok Oh
- Department of Internal Medicine, Haeundae Paik Hospital, Inje University College of Medicine, Busan, Korea
| | - Chang Min Heo
- Department of Internal Medicine, Haeundae Paik Hospital, Inje University College of Medicine, Busan, Korea
| | - Sangeon Gwoo
- Vascular Access Center, Lifeline Clinic, Busan, Korea
| | - Hyungkyu Huh
- Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, Korea
| | - Sungho Park
- Kangwon National University, Chuncheon, Korea
| | - Woon Heo
- Vascular Access Center, Lifeline Clinic, Busan, Korea
| |
Collapse
|
5
|
Higuita ML, Jain R, Osho AA, Rabi SA, Pruett TL, Pierson RN, Iaizzo PA, Tessier SN. Novel Imaging Technologies for Accurate Assessment of Cardiac Allograft Performance. CURRENT TRANSPLANTATION REPORTS 2023; 10:100-109. [PMID: 39015560 PMCID: PMC11251714 DOI: 10.1007/s40472-023-00400-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/12/2023] [Indexed: 07/18/2024]
Abstract
Purpose of the Review The current lack of objective and quantitative assessment techniques to determine cardiac graft relative viability results in risk-averse decision-making, which negatively impact the utilization of cardiac grafts. The purpose of this review is to highlight the current deficiencies in cardiac allograft assessment before focusing on novel cardiac assessment techniques that exploit conventional and emerging imaging modalities, including ultrasound, magnetic resonance, and spectroscopy. Recent Findings Extensive work is ongoing by the scientific community to identify improved objective metrics and tools for cardiac graft assessment, with the goal to safely increasing the number and proportion of hearts accepted for transplantation. Summary This review briefly discusses the in situ and ex vivo tools currently available for clinical organ assessment, before focusing on the individual capabilities of ultrasound, magnetic resonance, and spectroscopy to provide insightful, non-invasive information regarding cardiac graft functional and metabolic status that may be used to predict outcome after transplantation.
Collapse
Affiliation(s)
- Manuela Lopera Higuita
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
- Shriners Hospitals for Children, Boston, MA, USA
| | - Rohil Jain
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
- Shriners Hospitals for Children, Boston, MA, USA
| | - Asishana A. Osho
- Division of Cardiac Surgery, Corrigan Minehan Heart Center, Massachusetts General Hospital, MA, Boston, USA
| | - S. Alireza Rabi
- Division of Cardiac Surgery, Corrigan Minehan Heart Center, Massachusetts General Hospital, MA, Boston, USA
| | - Timothy L. Pruett
- Division of Solid Organ Transplantation and Department of Surgery, University of Minnesota, Minneapolis, MN, USA
| | - Richard N. Pierson
- Department of Surgery and Center for Transplantation Sciences, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Paul A. Iaizzo
- Visible Heart Laboratories, Departments of Surgery and Biomedical EngineeringInstitute for Engineering in Medicine, University of Minnesota, MN 55455 Minneapolis, USA
| | - Shannon N. Tessier
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
- Shriners Hospitals for Children, Boston, MA, USA
| |
Collapse
|
6
|
Maroun A, Quinn S, Dushfunian D, Weiss EK, Allen BD, Carr JC, Markl M. Clinical Applications of Four-Dimensional Flow MRI. Magn Reson Imaging Clin N Am 2023; 31:451-460. [PMID: 37414471 DOI: 10.1016/j.mric.2023.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/08/2023]
Abstract
Four-dimensional flow MRI is a powerful phase contrast technique used for assessing three-dimensional (3D) blood flow dynamics. By acquiring a time-resolved velocity field, it enables flexible retrospective analysis of blood flow that can include qualitative 3D visualization of complex flow patterns, comprehensive assessment of multiple vessels, reliable placement of analysis planes, and calculation of advanced hemodynamic parameters. This technique provides several advantages over routine two-dimensional flow imaging techniques, allowing it to become part of clinical practice at major academic medical centers. In this review, we present the current state-of-the-art cardiovascular, neurovascular, and abdominal applications.
Collapse
Affiliation(s)
- Anthony Maroun
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 North Michigan Avenue Suite 1600, Chicago, IL 60611, USA.
| | - Sandra Quinn
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 North Michigan Avenue Suite 1600, Chicago, IL 60611, USA
| | - David Dushfunian
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 North Michigan Avenue Suite 1600, Chicago, IL 60611, USA
| | - Elizabeth K Weiss
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 North Michigan Avenue Suite 1600, Chicago, IL 60611, USA
| | - Bradley D Allen
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 North Michigan Avenue Suite 1600, Chicago, IL 60611, USA
| | - James C Carr
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 North Michigan Avenue Suite 1600, Chicago, IL 60611, USA
| | - Michael Markl
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 North Michigan Avenue Suite 1600, Chicago, IL 60611, USA
| |
Collapse
|
7
|
Rajiah PS, Moore A, Broncano J, Anand V, Kolluri N, Shah DJ, Flamm SD, François CJ. Diastology with Cardiac MRI: A Practical Guide. Radiographics 2023; 43:e220144. [PMID: 37535462 DOI: 10.1148/rg.220144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/05/2023]
Abstract
Diastolic filling of the ventricle is a complex interplay of volume and pressure, contingent on active energy-dependent myocardial relaxation and myocardial stiffness. Abnormal diastolic function is the hallmark of the clinical entity of heart failure with preserved ejection fraction (HFpEF), which is now the dominant type of heart failure and is associated with significant morbidity and mortality. Although echocardiography is the current first-line imaging modality used in evaluation of diastolic function, cardiac MRI (CMR) is emerging as an important technique. The principal role of CMR is to categorize the cause of diastolic dysfunction (DD) and distinguish other entities that manifest similarly to HFpEF, particularly infiltrative and pericardial disorders. CMR also provides prognostic information and risk stratification based on late gadolinium enhancement and parametric mapping techniques. Advances in hardware, sequences, and postprocessing software now enable CMR to diagnose and grade DD accurately, a role traditionally assigned to echocardiography. Two-dimensional or four-dimensional velocity-encoded phase-contrast sequences can measure flow and velocities at the mitral inflow, mitral annulus, and pulmonary veins to provide diastolic functional metrics analogous to those at echocardiography. The commonly used cine steady-state free-precession sequence can provide clues to DD including left ventricular mass, left ventricular filling curves, and left atrial size and function. MR strain imaging provides information on myocardial mechanics that further aids in diagnosis and prognosis of diastolic function. Research sequences such as MR elastography and MR spectroscopy can help evaluate myocardial stiffness and metabolism, respectively, providing additional insights on diastolic function. The authors review the physiology of diastolic function, mechanics of diastolic heart failure, and CMR techniques in the evaluation of diastolic function. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.
Collapse
Affiliation(s)
- Prabhakar Shantha Rajiah
- From the Departments of Radiology (P.S.R., C.J.F.) and Cardiology (V.A., N.K.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905; Department of Radiology, Baylor Health System, Dallas, Tex (A.M.); Department of Radiology, Hospital San Juan de Dios, Hospital de la Cruz Roja, HT-RESALTA, HT Médica, Córdoba, Spain (J.B.); Department of Cardiology, Houston Methodist Hospital, Houston, Tex (D.J.S.); and Cardiovascular Imaging Laboratory, Cleveland Clinic Foundation, Cleveland, Ohio (S.D.F.)
| | - Alastair Moore
- From the Departments of Radiology (P.S.R., C.J.F.) and Cardiology (V.A., N.K.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905; Department of Radiology, Baylor Health System, Dallas, Tex (A.M.); Department of Radiology, Hospital San Juan de Dios, Hospital de la Cruz Roja, HT-RESALTA, HT Médica, Córdoba, Spain (J.B.); Department of Cardiology, Houston Methodist Hospital, Houston, Tex (D.J.S.); and Cardiovascular Imaging Laboratory, Cleveland Clinic Foundation, Cleveland, Ohio (S.D.F.)
| | - Jordi Broncano
- From the Departments of Radiology (P.S.R., C.J.F.) and Cardiology (V.A., N.K.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905; Department of Radiology, Baylor Health System, Dallas, Tex (A.M.); Department of Radiology, Hospital San Juan de Dios, Hospital de la Cruz Roja, HT-RESALTA, HT Médica, Córdoba, Spain (J.B.); Department of Cardiology, Houston Methodist Hospital, Houston, Tex (D.J.S.); and Cardiovascular Imaging Laboratory, Cleveland Clinic Foundation, Cleveland, Ohio (S.D.F.)
| | - Vidhu Anand
- From the Departments of Radiology (P.S.R., C.J.F.) and Cardiology (V.A., N.K.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905; Department of Radiology, Baylor Health System, Dallas, Tex (A.M.); Department of Radiology, Hospital San Juan de Dios, Hospital de la Cruz Roja, HT-RESALTA, HT Médica, Córdoba, Spain (J.B.); Department of Cardiology, Houston Methodist Hospital, Houston, Tex (D.J.S.); and Cardiovascular Imaging Laboratory, Cleveland Clinic Foundation, Cleveland, Ohio (S.D.F.)
| | - Nikhil Kolluri
- From the Departments of Radiology (P.S.R., C.J.F.) and Cardiology (V.A., N.K.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905; Department of Radiology, Baylor Health System, Dallas, Tex (A.M.); Department of Radiology, Hospital San Juan de Dios, Hospital de la Cruz Roja, HT-RESALTA, HT Médica, Córdoba, Spain (J.B.); Department of Cardiology, Houston Methodist Hospital, Houston, Tex (D.J.S.); and Cardiovascular Imaging Laboratory, Cleveland Clinic Foundation, Cleveland, Ohio (S.D.F.)
| | - Dipan J Shah
- From the Departments of Radiology (P.S.R., C.J.F.) and Cardiology (V.A., N.K.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905; Department of Radiology, Baylor Health System, Dallas, Tex (A.M.); Department of Radiology, Hospital San Juan de Dios, Hospital de la Cruz Roja, HT-RESALTA, HT Médica, Córdoba, Spain (J.B.); Department of Cardiology, Houston Methodist Hospital, Houston, Tex (D.J.S.); and Cardiovascular Imaging Laboratory, Cleveland Clinic Foundation, Cleveland, Ohio (S.D.F.)
| | - Scott D Flamm
- From the Departments of Radiology (P.S.R., C.J.F.) and Cardiology (V.A., N.K.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905; Department of Radiology, Baylor Health System, Dallas, Tex (A.M.); Department of Radiology, Hospital San Juan de Dios, Hospital de la Cruz Roja, HT-RESALTA, HT Médica, Córdoba, Spain (J.B.); Department of Cardiology, Houston Methodist Hospital, Houston, Tex (D.J.S.); and Cardiovascular Imaging Laboratory, Cleveland Clinic Foundation, Cleveland, Ohio (S.D.F.)
| | - Christopher J François
- From the Departments of Radiology (P.S.R., C.J.F.) and Cardiology (V.A., N.K.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905; Department of Radiology, Baylor Health System, Dallas, Tex (A.M.); Department of Radiology, Hospital San Juan de Dios, Hospital de la Cruz Roja, HT-RESALTA, HT Médica, Córdoba, Spain (J.B.); Department of Cardiology, Houston Methodist Hospital, Houston, Tex (D.J.S.); and Cardiovascular Imaging Laboratory, Cleveland Clinic Foundation, Cleveland, Ohio (S.D.F.)
| |
Collapse
|
8
|
Bissell MM, Raimondi F, Ait Ali L, Allen BD, Barker AJ, Bolger A, Burris N, Carhäll CJ, Collins JD, Ebbers T, Francois CJ, Frydrychowicz A, Garg P, Geiger J, Ha H, Hennemuth A, Hope MD, Hsiao A, Johnson K, Kozerke S, Ma LE, Markl M, Martins D, Messina M, Oechtering TH, van Ooij P, Rigsby C, Rodriguez-Palomares J, Roest AAW, Roldán-Alzate A, Schnell S, Sotelo J, Stuber M, Syed AB, Töger J, van der Geest R, Westenberg J, Zhong L, Zhong Y, Wieben O, Dyverfeldt P. 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update. J Cardiovasc Magn Reson 2023; 25:40. [PMID: 37474977 PMCID: PMC10357639 DOI: 10.1186/s12968-023-00942-z] [Citation(s) in RCA: 54] [Impact Index Per Article: 54.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 05/30/2023] [Indexed: 07/22/2023] Open
Abstract
Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.
Collapse
Affiliation(s)
- Malenka M Bissell
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), LIGHT Laboratories, Clarendon Way, University of Leeds, Leeds, LS2 9NL, UK.
| | | | - Lamia Ait Ali
- Institute of Clinical Physiology CNR, Massa, Italy
- Foundation CNR Tuscany Region G. Monasterio, Massa, Italy
| | - Bradley D Allen
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Alex J Barker
- Department of Radiology, Children's Hospital Colorado, University of Colorado Anschutz Medical Center, Aurora, USA
| | - Ann Bolger
- Department of Medicine, University of California, San Francisco, CA, USA
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Nicholas Burris
- Department of Radiology, University of Michigan, Ann Arbor, USA
| | - Carl-Johan Carhäll
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | | | - Tino Ebbers
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | | | - Alex Frydrychowicz
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck and Universität Zu Lübeck, Lübeck, Germany
| | - Pankaj Garg
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Julia Geiger
- Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland
- Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Hojin Ha
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, South Korea
| | - Anja Hennemuth
- Institute of Computer-Assisted Cardiovascular Medicine, Charité - Universitätsmedizin, Berlin, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site, Berlin, Germany
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael D Hope
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Albert Hsiao
- Department of Radiology, University of California, San Diego, CA, USA
| | - Kevin Johnson
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Liliana E Ma
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Michael Markl
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Duarte Martins
- Department of Pediatric Cardiology, Hospital de Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal
| | - Marci Messina
- Department of Radiology, Northwestern Medicine, Chicago, IL, USA
| | - Thekla H Oechtering
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck and Universität Zu Lübeck, Lübeck, Germany
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Pim van Ooij
- Department of Radiology & Nuclear Medicine, Amsterdam Cardiovascular Sciences, Amsterdam Movement Sciences, Amsterdam University Medical Centers, Location AMC, Amsterdam, The Netherlands
- Department of Pediatric Cardiology, Division of Pediatrics, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Cynthia Rigsby
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Department of Medical Imaging, Ann & Robert H Lurie Children's Hospital of Chicago, Chicago, IL, USA
| | - Jose Rodriguez-Palomares
- Department of Cardiology, Hospital Universitari Vall d´Hebron,Vall d'Hebron Institut de Recerca (VHIR), Universitat Autònoma de Barcelona, Barcelona, Spain
- Centro de Investigación Biomédica en Red-CV, CIBER CV, Madrid, Spain
| | - Arno A W Roest
- Department of Pediatric Cardiology, Willem-Alexander's Children Hospital, Leiden University Medical Center and Center for Congenital Heart Defects Amsterdam-Leiden, Leiden, The Netherlands
| | | | - Susanne Schnell
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Department of Medical Physics, Institute of Physics, University of Greifswald, Greifswald, Germany
| | - Julio Sotelo
- School of Biomedical Engineering, Universidad de Valparaíso, Valparaíso, Chile
- Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, Chile
- Millennium Institute for Intelligent Healthcare Engineering - iHEALTH, Santiago, Chile
| | - Matthias Stuber
- Département de Radiologie Médicale, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| | - Ali B Syed
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Johannes Töger
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden
| | - Rob van der Geest
- Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jos Westenberg
- CardioVascular Imaging Group (CVIG), Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Liang Zhong
- National Heart Centre Singapore, Duke-NUS Medical School, National University of Singapore, Singapore, Singapore
| | - Yumin Zhong
- Department of Radiology, School of Medicine, Shanghai Children's Medical Center Affiliated With Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Oliver Wieben
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Petter Dyverfeldt
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
9
|
Sun X, Cheng LH, Plein S, Garg P, Moghari MH, van der Geest RJ. Deep learning-based prediction of intra-cardiac blood flow in long-axis cine magnetic resonance imaging. Int J Cardiovasc Imaging 2023; 39:1045-1053. [PMID: 36763209 PMCID: PMC10160163 DOI: 10.1007/s10554-023-02804-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 01/22/2023] [Indexed: 02/11/2023]
Abstract
PURPOSE We aimed to design and evaluate a deep learning-based method to automatically predict the time-varying in-plane blood flow velocity within the cardiac cavities in long-axis cine MRI, validated against 4D flow. METHODS A convolutional neural network (CNN) was implemented, taking cine MRI as the input and the in-plane velocity derived from the 4D flow acquisition as the ground truth. The method was evaluated using velocity vector end-point error (EPE) and angle error. Additionally, the E/A ratio and diastolic function classification derived from the predicted velocities were compared to those derived from 4D flow. RESULTS For intra-cardiac pixels with a velocity > 5 cm/s, our method achieved an EPE of 8.65 cm/s and angle error of 41.27°. For pixels with a velocity > 25 cm/s, the angle error significantly degraded to 19.26°. Although the averaged blood flow velocity prediction was under-estimated by 26.69%, the high correlation (PCC = 0.95) of global time-varying velocity and the visual evaluation demonstrate a good agreement between our prediction and 4D flow data. The E/A ratio was derived with minimal bias, but with considerable mean absolute error of 0.39 and wide limits of agreement. The diastolic function classification showed a high accuracy of 86.9%. CONCLUSION Using a deep learning-based algorithm, intra-cardiac blood flow velocities can be predicted from long-axis cine MRI with high correlation with 4D flow derived velocities. Visualization of the derived velocities provides adjunct functional information and may potentially be used to derive the E/A ratio from conventional CMR exams.
Collapse
Affiliation(s)
- Xiaowu Sun
- Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Li-Hsin Cheng
- Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Pankaj Garg
- Norwich Medical School, University of East Anglia, Norwich, UK.,Norfolk and Norwich University Hospital Foundation Trust, Norwich, UK
| | - Mehdi H Moghari
- Department of Radiology, Children's Hospital Colorado, and School of Medicine, The University of Colorado, Boulder, CO, USA
| | - Rob J van der Geest
- Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
| |
Collapse
|
10
|
Sjöberg P, Hedström E, Fricke K, Frieberg P, Weismann CG, Liuba P, Carlsson M, Töger J. Comparison of 2D and 4D Flow MRI in Neonates Without General Anesthesia. J Magn Reson Imaging 2023; 57:71-82. [PMID: 35726779 PMCID: PMC10084310 DOI: 10.1002/jmri.28303] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 06/01/2022] [Accepted: 06/02/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Neonates with critical congenital heart disease require early intervention. Four-dimensional (4D) flow may facilitate surgical planning and improve outcome, but accuracy and precision in neonates are unknown. PURPOSE To 1) validate two-dimensional (2D) and 4D flow MRI in a phantom and investigate the effect of spatial and temporal resolution; 2) investigate accuracy and precision of 4D flow and internal consistency of 2D and 4D flow in neonates; and 3) compare scan time of 4D flow to multiple 2D flows. STUDY TYPE Phantom and prospective patients. POPULATION A total of 17 neonates with surgically corrected aortic coarctation (age 18 days [IQR 11-20]) and a three-dimensional printed neonatal aorta phantom. FIELD STRENGTH/SEQUENCE 1.5T, 2D flow and 4D flow. ASSESSMENT In the phantom, 2D and 4D flow volumes (ascending and descending aorta, and aortic arch vessels) with different resolutions were compared to high-resolution reference 2D flow. In neonates, 4D flow was compared to 2D flow volumes at each vessel. Internal consistency was computed as the flow volume in the ascending aorta minus the sum of flow volumes in the aortic arch vessels and descending aorta, divided by ascending aortic flow. STATISTICAL TESTS Bland-Altman plots, Pearson correlation coefficient (r), and Student's t-tests. RESULTS In the phantom, 2D flow differed by 0.01 ± 0.02 liter/min with 1.5 mm spatial resolution and -0.01 ± 0.02 liter/min with 0.8 mm resolution; 4D flow differed by -0.05 ± 0.02 liter/min with 2.4 mm spatial and 42 msec temporal resolution, -0.01 ± 0.02 liter/min with 1.5 mm, 42 msec resolution and -0.01 ± 0.02 liter/min with 1.5 mm, 21 msec resolution. In patients, 4D flow and 2D flow differed by -0.06 ± 0.08 liter/min. Internal consistency in patients was -11% ± 17% for 2D flow and 5% ± 13% for 4D flow. Scan time was 17.1 minutes [IQR 15.5-18.5] for 2D flow and 6.2 minutes [IQR 5.3-6.9] for 4D flow, P < 0.0001. DATA CONCLUSION Neonatal 4D flow MRI is time efficient and can be acquired with good internal consistency without contrast agents or general anesthesia, thus potentially expanding 4D flow use to the youngest and smallest patients. EVIDENCE LEVEL 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Pia Sjöberg
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund
| | - Erik Hedström
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund.,Diagnostic Radiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden
| | - Katrin Fricke
- Pediatric Heart Center, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden
| | - Petter Frieberg
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund
| | - Constance G Weismann
- Pediatric Heart Center, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden
| | - Petru Liuba
- Pediatric Heart Center, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden
| | - Marcus Carlsson
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund
| | - Johannes Töger
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund
| |
Collapse
|
11
|
Gorecka M, Bissell MM, Higgins DM, Garg P, Plein S, Greenwood JP. Rationale and clinical applications of 4D flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review. J Cardiovasc Magn Reson 2022; 24:49. [PMID: 35989320 PMCID: PMC9394062 DOI: 10.1186/s12968-022-00882-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 08/04/2022] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Accurate evaluation of valvular pathology is crucial in the timing of surgical intervention. Whilst transthoracic echocardiography is widely available and routinely used in the assessment of valvular heart disease, it is bound by several limitations. Although cardiovascular magnetic resonance (CMR) imaging can overcome many of the challenges encountered by echocardiography, it also has a number of limitations. MAIN TEXT 4D Flow CMR is a novel technique, which allows time-resolved, 3-dimensional imaging. It enables visualisation and direct quantification of flow and peak velocities of all valves simultaneously in one simple acquisition, without any geometric assumptions. It also has the unique ability to measure advanced haemodynamic parameters such as turbulent kinetic energy, viscous energy loss rate and wall shear stress, which may add further diagnostic and prognostic information. Although 4D Flow CMR acquisition can take 5-10 min, emerging acceleration techniques can significantly reduce scan times, making 4D Flow CMR applicable in contemporary clinical practice. CONCLUSION 4D Flow CMR is an emerging CMR technique, which has the potential to become the new reference-standard method for the evaluation of valvular lesions. In this review, we describe the clinical applications, advantages and disadvantages of 4D Flow CMR in the assessment of valvular heart disease.
Collapse
Affiliation(s)
- Miroslawa Gorecka
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - Malenka M Bissell
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | | | - Pankaj Garg
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - John P Greenwood
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT, UK.
| |
Collapse
|
12
|
Warmerdam EG, Neijzen RL, Voskuil M, Leiner T, Grotenhuis HB. Four-dimensional flow CMR in tetralogy of fallot: current perspectives. Br J Radiol 2022; 95:20210298. [PMID: 35073171 PMCID: PMC10993958 DOI: 10.1259/bjr.20210298] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 11/06/2021] [Accepted: 01/12/2022] [Indexed: 11/05/2022] Open
Abstract
Tetralogy of Fallot is the most common cyanotic congenital heart defect, accounting for 10% of all CHD. Despite most patients now surviving well into adulthood, morbidity and mortality rates continue to be high. Surgical and percutaneous pulmonary valve replacement are procedures that are performed to prevent long-term complications from occurring. Unfortunately, pulmonary valve replacement based on current CMR criteria does not prevent postoperative ventricular arrhythmia, heart failure, and sudden cardiac death. Thus, a more advanced and comprehensive hemodynamic evaluation is needed to better understand right ventricular (dys)function in tetralogy of Fallot patients and to optimize the timing of valve replacement. Recently, four-dimensional flow CMR has emerged as a promising and non-invasive imaging technique that can provide comprehensive quantitative evaluation of flow in an entire volume within the chest in a single imaging session. With velocity-encoding in all three spatial directions throughout the complete cardiac cycle, it can provide analysis of cardiac, pulmonary artery and aortic flow volumes, flow velocities, flow patterns, as well as more advanced hemodynamic parameters. Four-dimensional flow CMR could therefore provide insights into the complex hemodynamics of tetralogy of Fallot and could potentially provide novel criteria for pulmonary valve replacement in these patients. The aim of this review is to provide an overview of available research on four-dimensional flow CMR research in tetralogy of Fallot patients.
Collapse
Affiliation(s)
- Evangeline Gerdine Warmerdam
- Department of Cardiology, University Medical Center Utrecht,
Heidelberglaan, Utrecht,
The Netherlands
- Department of Paediatric Cardiology, University Medical Center
Utrecht, Heidelberglaan, Utrecht,
The Netherlands
| | - Rosalie Lucy Neijzen
- Department of Paediatric Cardiology, University Medical Center
Utrecht, Heidelberglaan, Utrecht,
The Netherlands
- Honours Program Faculty of Medicine, University Medical Center
Utrecht, Utrecht, The
Netherlands
| | - Michiel Voskuil
- Department of Cardiology, University Medical Center Utrecht,
Heidelberglaan, Utrecht,
The Netherlands
| | - Tim Leiner
- Department of Radiology, University Medical Center Utrecht,
Heidelberglaan, Utrecht,
The Netherlands
| | - Heynric B Grotenhuis
- Department of Paediatric Cardiology, University Medical Center
Utrecht, Heidelberglaan, Utrecht,
The Netherlands
| |
Collapse
|
13
|
Gupta AN, Avery R, Soulat G, Allen BD, Collins JD, Choudhury L, Bonow RO, Carr J, Markl M, Elbaz MSM. Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR. J Cardiovasc Magn Reson 2021; 23:138. [PMID: 34865629 PMCID: PMC8647422 DOI: 10.1186/s12968-021-00828-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 11/16/2021] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet tracking in comparison to standard-of-care CMR indirect volumetric method. METHODS This retrospective study included patients with HCM undergoing 4D flow CMR. By the indirect volumetric method from CMR, MR volume was quantified as left ventricular stroke volume minus forward aortic volume. By 4D flow CMR direct jet tracking, multiplanar reformatted planes were positioned in the peak velocity of the MR jet during systole to calculate through-plane regurgitant flow. MR severity was collected for agreement analysis from a clinical echocardiograms performed within 1 month of CMR. Inter-method and inter-observer agreement were assessed by intraclass correlation coefficient (ICC), Bland-Altman analysis, and Cohen's kappa. RESULTS Thirty-seven patients with HCM were included. Direct jet tracking demonstrated good inter-method agreement of MR volume compared to the indirect volumetric method (ICC = 0.80, p = 0.004) and fair agreement of MR severity (kappa = 0.27, p = 0.03). Direct jet tracking showed higher agreement with echocardiography (kappa = 0.35, p = 0.04) than indirect volumetric method (kappa = 0.16, p = 0.35). Inter-observer reproducibility of indirect volumetric method components revealed the lowest reproducibility in end-systolic volume (ICC = 0.69, p = 0.15). Indirect volumetric method showed good agreement of MR volume (ICC = 0.80, p = 0.003) and fair agreement of MR severity (kappa = 0.38, p < 0.001). Direct jet tracking demonstrated (1) excellent inter-observer reproducibility of MR volume (ICC = 0.97, p < 0.001) and MR severity (kappa = 0.84, p < 0.001) and (2) excellent intra-observer reproducibility of MR volume (ICC = 0.98, p < 0.001) and MR severity (kappa = 0.88, p < 0.001). CONCLUSIONS Quantifying MR and assessing MR severity by indirect volumetric method in HCM patients has limited inter-observer reproducibility. 4D flow CMR jet tracking is a potential alternative technique to directly quantify and assess MR severity with excellent inter- and intra-observer reproducibility and higher agreement with echocardiography in this population.
Collapse
Affiliation(s)
- Aakash N Gupta
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan, Suite 1600, Chicago, IL, 60611, USA
| | - Ryan Avery
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan, Suite 1600, Chicago, IL, 60611, USA
| | - Gilles Soulat
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan, Suite 1600, Chicago, IL, 60611, USA
| | - Bradley D Allen
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan, Suite 1600, Chicago, IL, 60611, USA
| | | | - Lubna Choudhury
- Department of Medicine, Division of Cardiology, Northwestern University, Feinberg School of Medicine, Chicago, IL, 60611, USA
| | - Robert O Bonow
- Department of Medicine, Division of Cardiology, Northwestern University, Feinberg School of Medicine, Chicago, IL, 60611, USA
| | - James Carr
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan, Suite 1600, Chicago, IL, 60611, USA
| | - Michael Markl
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan, Suite 1600, Chicago, IL, 60611, USA
- Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, IL, 60208, USA
| | - Mohammed S M Elbaz
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan, Suite 1600, Chicago, IL, 60611, USA.
| |
Collapse
|
14
|
Westenberg JJM, van Assen HC, van den Boogaard PJ, Goeman JJ, Saaid H, Voorneveld J, Bosch J, Kenjeres S, Claessens T, Garg P, Kouwenhoven M, Lamb HJ. Echo planar imaging-induced errors in intracardiac 4D flow MRI quantification. Magn Reson Med 2021; 87:2398-2411. [PMID: 34866236 PMCID: PMC9300143 DOI: 10.1002/mrm.29112] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 11/16/2021] [Accepted: 11/16/2021] [Indexed: 01/09/2023]
Abstract
Purpose To assess errors associated with EPI‐accelerated intracardiac 4D flow MRI (4DEPI) with EPI factor 5, compared with non‐EPI gradient echo (4DGRE). Methods Three 3T MRI experiments were performed comparing 4DEPI to 4DGRE: steady flow through straight tubes, pulsatile flow in a left‐ventricle phantom, and intracardiac flow in 10 healthy volunteers. For each experiment, 4DEPI was repeated with readout and blip phase‐encoding gradient in different orientations, parallel or perpendicular to the flow direction. In vitro flow rates were compared with timed volumetric collection. In the left‐ventricle phantom and in vivo, voxel‐based speed and spatio‐temporal median speed were compared between sequences, as well as mitral and aortic transvalvular net forward volume. Results In steady‐flow phantoms, the flow rate error was largest (12%) for high velocity (>2 m/s) with 4DEPI readout gradient parallel to the flow. Voxel‐based speed and median speed in the left‐ventricle phantom were ≤5.5% different between sequences. In vivo, mean net forward volume inconsistency was largest (6.4 ± 8.5%) for 4DEPI with nonblip phase‐encoding gradient parallel to the main flow. The difference in median speed for 4DEPI versus 4DGRE was largest (9%) when the 4DEPI readout gradient was parallel to the flow. Conclusions Velocity and flow rate are inaccurate for 4DEPI with EPI factor 5 when flow is parallel to the readout or blip phase‐encoding gradient. However, mean differences in flow rate, voxel‐based speed, and spatio‐temporal median speed were acceptable (≤10%) when comparing 4DEPI to 4DGRE for intracardiac flow in healthy volunteers.
Collapse
Affiliation(s)
- Jos J M Westenberg
- CardioVascular Imaging Group, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Hans C van Assen
- CardioVascular Imaging Group, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Pieter J van den Boogaard
- CardioVascular Imaging Group, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Jelle J Goeman
- Department of Biomedical Data Sciences, Leiden University Medical Center, Leiden, the Netherlands
| | - Hicham Saaid
- Institute Biomedical Technology, Ghent University, Ghent, Belgium
| | - Jason Voorneveld
- Department of Biomedical Engineering, Erasmus Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Johan Bosch
- Department of Biomedical Engineering, Erasmus Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Sasa Kenjeres
- Department of Chemical Engineering, Delft University of Technology, Delft, the Netherlands
| | - Tom Claessens
- Department of Materials, Textiles and Chemical Engineering, Ghent University, Ghent, Belgium
| | - Pankaj Garg
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Marc Kouwenhoven
- Department of MR R&D-Clinical Science, Philips, Best, the Netherlands
| | - Hildo J Lamb
- CardioVascular Imaging Group, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
15
|
Gonzales RA, Seemann F, Lamy J, Mojibian H, Atar D, Erlinge D, Steding-Ehrenborg K, Arheden H, Hu C, Onofrey JA, Peters DC, Heiberg E. MVnet: automated time-resolved tracking of the mitral valve plane in CMR long-axis cine images with residual neural networks: a multi-center, multi-vendor study. J Cardiovasc Magn Reson 2021; 23:137. [PMID: 34857009 PMCID: PMC8638514 DOI: 10.1186/s12968-021-00824-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 10/20/2021] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Mitral annular plane systolic excursion (MAPSE) and left ventricular (LV) early diastolic velocity (e') are key metrics of systolic and diastolic function, but not often measured by cardiovascular magnetic resonance (CMR). Its derivation is possible with manual, precise annotation of the mitral valve (MV) insertion points along the cardiac cycle in both two and four-chamber long-axis cines, but this process is highly time-consuming, laborious, and prone to errors. A fully automated, consistent, fast, and accurate method for MV plane tracking is lacking. In this study, we propose MVnet, a deep learning approach for MV point localization and tracking capable of deriving such clinical metrics comparable to human expert-level performance, and validated it in a multi-vendor, multi-center clinical population. METHODS The proposed pipeline first performs a coarse MV point annotation in a given cine accurately enough to apply an automated linear transformation task, which standardizes the size, cropping, resolution, and heart orientation, and second, tracks the MV points with high accuracy. The model was trained and evaluated on 38,854 cine images from 703 patients with diverse cardiovascular conditions, scanned on equipment from 3 main vendors, 16 centers, and 7 countries, and manually annotated by 10 observers. Agreement was assessed by the intra-class correlation coefficient (ICC) for both clinical metrics and by the distance error in the MV plane displacement. For inter-observer variability analysis, an additional pair of observers performed manual annotations in a randomly chosen set of 50 patients. RESULTS MVnet achieved a fast segmentation (<1 s/cine) with excellent ICCs of 0.94 (MAPSE) and 0.93 (LV e') and a MV plane tracking error of -0.10 ± 0.97 mm. In a similar manner, the inter-observer variability analysis yielded ICCs of 0.95 and 0.89 and a tracking error of -0.15 ± 1.18 mm, respectively. CONCLUSION A dual-stage deep learning approach for automated annotation of MV points for systolic and diastolic evaluation in CMR long-axis cine images was developed. The method is able to carefully track these points with high accuracy and in a timely manner. This will improve the feasibility of CMR methods which rely on valve tracking and increase their utility in a clinical setting.
Collapse
Affiliation(s)
- Ricardo A. Gonzales
- Clinical Physiology, Department of Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, Connecticut United States of America
- Department of Electrical Engineering, Universidad de Ingeniería y Tecnología, Lima, Peru
| | - Felicia Seemann
- Clinical Physiology, Department of Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, Connecticut United States of America
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Jérôme Lamy
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, Connecticut United States of America
| | - Hamid Mojibian
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, Connecticut United States of America
| | - Dan Atar
- Department of Cardiology B, Oslo University Hospital Ullevål and Faculty of Medicine, University of Oslo, Oslo, Norway
| | - David Erlinge
- Department of Cardiology, Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden
| | - Katarina Steding-Ehrenborg
- Clinical Physiology, Department of Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden
| | - Håkan Arheden
- Clinical Physiology, Department of Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden
| | - Chenxi Hu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - John A. Onofrey
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, Connecticut United States of America
- Department of Urology, Yale School of Medicine, Yale University, New Haven, Connecticut United States of America
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut United States of America
| | - Dana C. Peters
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, Connecticut United States of America
| | - Einar Heiberg
- Clinical Physiology, Department of Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden
- Department of Biomedical Engineering, Lund University, Lund, Sweden
- Wallenberg Center for Molecular Medicine, Lund University, Lund, Sweden
| |
Collapse
|
16
|
Lee J, Gupta AN, Ma LE, Scott MB, Mason OR, Wu E, Thomas JD, Markl M. Valvular regurgitation flow jet assessment using in vitro 4D flow MRI: Implication for mitral regurgitation. Magn Reson Med 2021; 87:1923-1937. [PMID: 34783383 DOI: 10.1002/mrm.29082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 10/01/2021] [Accepted: 10/25/2021] [Indexed: 11/11/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the accuracy of four-dimensional (4D) flow MRI for direct assessment of peak velocity, flow volume, and momentum of a mitral regurgitation (MR) flow jets using an in vitro pulsatile jet flow phantom. We systematically investigated the impact of spatial resolution and quantification location along the jet on flow quantities with Doppler ultrasound as a reference for peak velocity. METHODS Four-dimensional flow MRI data of a pulsatile jet through a circular, elliptical, and 3D-printed patient-specific MR orifice model was acquired with varying spatial resolution (1.5-5 mm isotropic voxel). Flow rate and momentum of the jet were quantified at various axial distances (x = 0-50 mm) and integrated over time to calculate Voljet and MTIjet . In vivo assessment of Voljet and MTIjet was performed on 3 MR patients. RESULTS Peak velocities were comparable to Doppler ultrasound (3% error, 1.5 mm voxel), but underestimated with decreasing spatial resolution (-40% error, 5 mm voxel). Voljet was similar to regurgitant volume (RVol) within 5 mm, and then increased linearly with the axial distance (19%/cm) because of flow entrainment. MTIjet remained steady throughout the jet (2%/cm) as theoretically predicted. Four and 9 voxels across the jet were required to measure flow volume and momentum-time-integral within 10% error, respectively. CONCLUSION Four-dimensional flow MRI detected accurate peak velocity, flow rate, and momentum for in vitro MR-mimicking flow jets. Spatial resolution significantly impacted flow quantitation, which otherwise followed predictions of flow entrainment and momentum conservation. This study provides important preliminary information for accurate in vivo MR assessment using 4D flow MRI.
Collapse
Affiliation(s)
- Jeesoo Lee
- Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois, USA
| | - Aakash N Gupta
- Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois, USA
| | - Liliana E Ma
- Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois, USA
| | - Michel B Scott
- Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois, USA
| | - O'Neil R Mason
- Division of Cardiology, Northwestern Memorial Hospital, Chicago, Illinois, USA
| | - Erik Wu
- Division of Cardiology, Northwestern Memorial Hospital, Chicago, Illinois, USA
| | - James D Thomas
- Division of Cardiology, Northwestern Memorial Hospital, Chicago, Illinois, USA
| | - Michael Markl
- Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Illinois, USA
| |
Collapse
|
17
|
Lagerstrand KM, Truedsson F, Gao SA, Johansson A, Bech-Hanssen O, Polte CL, Johnsson ÅA. Importance of through-plane heart motion correction for the assessment of aortic regurgitation severity using phase contrast magnetic resonance imaging. Magn Reson Imaging 2021; 84:69-75. [PMID: 34560232 DOI: 10.1016/j.mri.2021.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 09/11/2021] [Accepted: 09/16/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To elucidate the influence of through-plane heart motion on the assessment of aortic regurgitation (AR) severity using phase contrast magnetic resonance imaging (PC-MRI). APPROACH A patient cohort with chronic AR (n = 34) was examined with PC-MRI. The regurgitant volume (RVol) and fraction (RFrac) were extracted from the PC-MRI data before and after through-plane heart motion correction and was then used for assessment of AR severity. RESULTS The flow volume errors were strongly correlated to aortic diameter (R = 0.80, p < 0.001) with median (IQR 25%;75%): 16 (14; 17) ml for diameter>40mm, compared with 9 (7; 10) ml for normal aortic size (p < 0.001). RVol and RFrac were underestimated (uncorrected:64 ± 37 ml and 39 ± 17%; corrected:76 ± 37 ml and 44 ± 15%; p < 0.001) and ~ 20% of the patients received lower severity grade without correction. CONCLUSION Through-plane heart motion introduces relevant flow volume errors, especially in patients with aortic dilatation that may result in underestimation of the severity grade in patients with chronic AR.
Collapse
Affiliation(s)
- Kerstin M Lagerstrand
- Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden; Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden.
| | - Frida Truedsson
- Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden; Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Sinsia A Gao
- Department of Molecular and Clinical Medicine, Institute of Medicine, The Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden; Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Alexander Johansson
- Department of Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Odd Bech-Hanssen
- Department of Molecular and Clinical Medicine, Institute of Medicine, The Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden; Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Christian L Polte
- Department of Molecular and Clinical Medicine, Institute of Medicine, The Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden; Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg, Sweden; Department of Cardiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Åse A Johnsson
- Department of Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden; Department of Radiology, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, Sweden
| |
Collapse
|
18
|
Zhuang B, Sirajuddin A, Zhao S, Lu M. The role of 4D flow MRI for clinical applications in cardiovascular disease: current status and future perspectives. Quant Imaging Med Surg 2021; 11:4193-4210. [PMID: 34476199 DOI: 10.21037/qims-20-1234] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 04/23/2021] [Indexed: 11/06/2022]
Abstract
Magnetic resonance imaging (MRI) four-dimensional (4D) flow is a type of phase-contrast (PC) MRI that uses blood flow encoded in 3 directions, which is resolved relative to 3 spatial and temporal dimensions of cardiac circulation. It can be used to simultaneously quantify and visualize hemodynamics or morphology disorders. 4D flow MRI is more comprehensive and accurate than two-dimensional (2D) PC MRI and echocardiography. 4D flow MRI provides numerous hemodynamic parameters that are not limited to the basic 2D parameters, including wall shear stress (WSS), pulse wave velocity (PWV), kinetic energy, turbulent kinetic energy (TKE), pressure gradient, and flow component analysis. 4D flow MRI is widely used to image many parts of the body, such as the neck, brain, and liver, and has a wide application spectrum to cardiac diseases and large vessels. This present review aims to summarize the hemodynamic parameters of 4D flow MRI technology and generalize their usefulness in clinical practice in relation to the cardiovascular system. In addition, we note the improvements that have been made to 4D flow MRI with the application of new technologies. The application of new technologies can improve the speed of 4D flow, which would benefit clinical applications.
Collapse
Affiliation(s)
- Baiyan Zhuang
- Department of Magnetic Resonance Imaging, Fuwai Hospital, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Arlene Sirajuddin
- National Heart, Lung and Blood Institute (NHLBI), National Institutes of Health (NIH), Bethesda, MD, USA
| | - Shihua Zhao
- Department of Magnetic Resonance Imaging, Fuwai Hospital, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Minjie Lu
- Department of Magnetic Resonance Imaging, Fuwai Hospital, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.,Key Laboratory of Cardiovascular Imaging (Cultivation), Chinese Academy of Medical Sciences, Beijing, China
| |
Collapse
|
19
|
Doyle CM, Orr J, Greenwood JP, Plein S, Tsoumpas C, Bissell MM. Four-Dimensional Flow Magnetic Resonance Imaging in the Assessment of Blood Flow in the Heart and Great Vessels: A Systematic Review. J Magn Reson Imaging 2021; 55:1301-1321. [PMID: 34416048 DOI: 10.1002/jmri.27874] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 07/22/2021] [Accepted: 07/23/2021] [Indexed: 12/28/2022] Open
Abstract
Four-dimensional (4D) flow magnetic resonance imaging (MRI) allows multidirectional quantification of blood flow in the heart and great vessels. Comparability of the technique to the current reference standards of flow assessment-two-dimensional (2D) flow MRI and Doppler echocardiography-varies in the literature. Image acquisition parameters likely impact upon the accuracy and reproducibility of 4D flow MRI. We therefore sought to review the current literature on 4D flow MRI in the heart and great vessels, in comparison to 2D flow MRI, Doppler echocardiography, and invasive catheterization. Using a predefined search strategy and inclusion and exclusion criteria, the databases EMBASE and Medline were searched in January 2021 for peer-reviewed research articles comparing cardiac 4D flow MRI to 2D flow MRI, Doppler echocardiography and/or invasive catheterization. The data from all relevant articles were assimilated and analyzed using Mann-Whitney U and chi χ2 test. Forty-four manuscripts met the eligibility criteria and were included in the review. The review showed agreement of 4D flow MRI to the reference standard methods of flow assessment, particular in the measurement of peak velocity and stroke volume in 55% of manuscripts. The use of valve tracking significantly improves agreement between 4D flow MRI and the reference modalities (79% matching with the use of valve tracking vs. 50% without, P = 0.04). This review highlights that the impact of acquisition parameters on 4D flow MRI accuracy is multifactorial. It is therefore important that each center conducts its own quality assurance prior to using 4D flow MRI for clinical decision-making. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Ciara M Doyle
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, UK
| | - Jenny Orr
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, UK
| | - John P Greenwood
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, UK
| | - Sven Plein
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, UK
| | - Charalampos Tsoumpas
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, UK.,Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Malenka M Bissell
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, UK
| |
Collapse
|
20
|
Spampinato RA, Jahnke C, Crelier G, Lindemann F, Fahr F, Czaja-Ziolkowska M, Sieg F, Strotdrees E, Hindricks G, Borger MA, Paetsch I. Quantification of regurgitation in mitral valve prolapse with four-dimensional flow cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2021; 23:87. [PMID: 34233708 PMCID: PMC8265147 DOI: 10.1186/s12968-021-00783-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2020] [Accepted: 05/26/2021] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Four-dimensional cardiovascular magnetic resonance (CMR) flow assessment (4D flow) allows to derive volumetric quantitative parameters in mitral regurgitation (MR) using retrospective valve tracking. However, prior studies have been conducted in functional MR or in patients with congenital heart disease, thus, data regarding the usefulness of 4D flow CMR in case of a valve pathology like mitral valve prolapse (MVP) are scarce. This study aimed to evaluate the clinical utility of cine-guided valve segmentation of 4D flow CMR in assessment of MR in MVP when compared to standardized routine CMR and transthoracic echocardiography (TTE). METHODS Six healthy subjects and 54 patients (55 ± 16 years; 47 men) with MVP were studied. TTE severity grading used a multiparametric approach resulting in mild/mild-moderate (n = 12), moderate-severe (n = 12), and severe MR (n = 30). Regurgitant volume (RVol) and regurgitant fraction (RF) were also derived using standard volumetric CMR and 4D flow CMR datasets with direct measurement of regurgitant flow (4DFdirect) and indirect calculation using the formula: mitral valve forward flow - left ventricular outflow tract stroke volume (4DFindirect). RESULTS There was moderate to strong correlation between methods (r = 0.59-0.84, p < 0.001), but TTE proximal isovelocity surface area (PISA) method showed higher RVol as compared with CMR techniques (PISA vs. CMR, mean difference of 15.8 ml [95% CI 9.9-21.6]; PISA vs. 4DFindirect, 17.2 ml [8.4-25.9]; PISA vs. 4DFdirect, 27.9 ml [19.1-36.8]; p < 0.001). Only indirect CMR methods (CMR vs. 4DFindirect) showed moderate to substantial agreement (Lin's coefficient 0.92-0.97) without significant bias (mean bias 1.05 ± 26 ml [- 50 to 52], p = 0.757). Intra- and inter-observer reliability were good to excellent for all methods (ICC 0.87-0.99), but with numerically lower coefficient of variation for indirect CMR methods (2.5 to 12%). CONCLUSIONS In the assessment of patients with MR and MVP, cine-guided valve segmentation 4D flow CMR is feasible and comparable to standard CMR, but with lower RVol when TTE is used as reference. 4DFindirect quantification has higher intra- and inter-technique agreement than 4DFdirect quantification and might be used as an adjunctive technique for cross-checking MR quantification in MVP.
Collapse
Affiliation(s)
- Ricardo A Spampinato
- Department of Cardiac Surgery, Heart Center Leipzig at University of Leipzig, Struempellstrasse 39, 04289, Leipzig, Germany.
| | - Cosima Jahnke
- Department of Cardiology and Electrophysiology, Heart Center Leipzig at University of Leipzig, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Gerard Crelier
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Frank Lindemann
- Department of Cardiology and Electrophysiology, Heart Center Leipzig at University of Leipzig, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Florian Fahr
- Department of Cardiac Surgery, Heart Center Leipzig at University of Leipzig, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Monika Czaja-Ziolkowska
- Department of Cardiology and Electrophysiology, Heart Center Leipzig at University of Leipzig, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Franz Sieg
- Department of Cardiac Surgery, Heart Center Leipzig at University of Leipzig, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Elfriede Strotdrees
- Department of Cardiac Surgery, Heart Center Leipzig at University of Leipzig, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Gerhard Hindricks
- Department of Cardiology and Electrophysiology, Heart Center Leipzig at University of Leipzig, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Michael A Borger
- Department of Cardiac Surgery, Heart Center Leipzig at University of Leipzig, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Ingo Paetsch
- Department of Cardiology and Electrophysiology, Heart Center Leipzig at University of Leipzig, Struempellstrasse 39, 04289, Leipzig, Germany
| |
Collapse
|
21
|
Demirkiran A, van Ooij P, Westenberg JJM, Hofman MBM, van Assen HC, Schoonmade LJ, Asim U, Blanken CPS, Nederveen AJ, van Rossum AC, Götte MJW. Clinical intra-cardiac 4D flow CMR: acquisition, analysis, and clinical applications. Eur Heart J Cardiovasc Imaging 2021; 23:154-165. [PMID: 34143872 PMCID: PMC8787996 DOI: 10.1093/ehjci/jeab112] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 05/25/2021] [Indexed: 12/13/2022] Open
Abstract
Identification of flow patterns within the heart has long been recognized as a potential contribution to the understanding of physiological and pathophysiological processes of cardiovascular diseases. Although the pulsatile flow itself is multi-dimensional and multi-directional, current available non-invasive imaging modalities in clinical practice provide calculation of flow in only 1-direction and lack 3-dimensional volumetric velocity information. Four-dimensional flow cardiovascular magnetic resonance imaging (4D flow CMR) has emerged as a novel tool that enables comprehensive and critical assessment of flow through encoding velocity in all 3 directions in a volume of interest resolved over time. Following technical developments, 4D flow CMR is not only capable of visualization and quantification of conventional flow parameters such as mean/peak velocity and stroke volume but also provides new hemodynamic parameters such as kinetic energy. As a result, 4D flow CMR is being extensively exploited in clinical research aiming to improve understanding of the impact of cardiovascular disease on flow and vice versa. Of note, the analysis of 4D flow data is still complex and accurate analysis tools that deliver comparable quantification of 4D flow values are a necessity for a more widespread adoption in clinic. In this article, the acquisition and analysis processes are summarized and clinical applications of 4D flow CMR on the heart including conventional and novel hemodynamic parameters are discussed. Finally, clinical potential of other emerging intra-cardiac 4D flow imaging modalities is explored and a near-future perspective on 4D flow CMR is provided.
Collapse
Affiliation(s)
- Ahmet Demirkiran
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam Cardiovascular Sciences, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Pim van Ooij
- Department of Radiology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Jos J M Westenberg
- Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Mark B M Hofman
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Hans C van Assen
- Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Linda J Schoonmade
- Medical Library, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Usman Asim
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam Cardiovascular Sciences, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Carmen P S Blanken
- Department of Radiology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Aart J Nederveen
- Department of Radiology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Albert C van Rossum
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam Cardiovascular Sciences, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Marco J W Götte
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam Cardiovascular Sciences, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| |
Collapse
|
22
|
Elsayed A, Gilbert K, Scadeng M, Cowan BR, Pushparajah K, Young AA. Four-dimensional flow cardiovascular magnetic resonance in tetralogy of Fallot: a systematic review. J Cardiovasc Magn Reson 2021; 23:59. [PMID: 34011372 PMCID: PMC8136126 DOI: 10.1186/s12968-021-00745-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 03/17/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Patients with repaired Tetralogy of Fallot (rTOF) often develop cardiovascular dysfunction and require regular imaging to evaluate deterioration and time interventions such as pulmonary valve replacement. Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) enables detailed assessment of flow characteristics in all chambers and great vessels. We performed a systematic review of intra-cardiac 4D flow applications in rTOF patients, to examine clinical utility and highlight optimal methods for evaluating rTOF patients. METHODS A comprehensive literature search was undertaken in March 2020 on Google Scholar and Scopus. A modified version of the Critical Appraisal Skills Programme (CASP) tool was used to assess and score the applicability of each study. Important clinical outcomes were assessed including similarities and differences. RESULTS Of the 635 articles identified, 26 studies met eligibility for systematic review. None of these were below 59% applicability on the modified CASP score. Studies could be broadly classified into four groups: (i) pilot studies, (ii) development of new acquisition methods, (iii) validation and (vi) identification of novel flow features. Quantitative comparison with other modalities included 2D phase contrast CMR (13 studies) and echocardiography (4 studies). The 4D flow study applications included stroke volume (18/26;69%), regurgitant fraction (16/26;62%), relative branch pulmonary artery flow(4/26;15%), systolic peak velocity (9/26;35%), systemic/pulmonary total flow ratio (6/26;23%), end diastolic and end systolic volume (5/26;19%), kinetic energy (5/26;19%) and vorticity (2/26;8%). CONCLUSIONS 4D flow CMR shows potential in rTOF assessment, particularly in retrospective valve tracking for flow evaluation, velocity profiling, intra-cardiac kinetic energy quantification, and vortex visualization. Protocols should be targeted to pathology. Prospective, randomized, multi-centered studies are required to validate these new characteristics and establish their clinical use.
Collapse
Affiliation(s)
- Ayah Elsayed
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
| | - Kathleen Gilbert
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Miriam Scadeng
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
| | - Brett R. Cowan
- Institute of Environmental Science and Research, Auckland, New Zealand
| | | | - Alistair A. Young
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
- Department of Biomedical Engineering, King’s College London, London, UK
| |
Collapse
|
23
|
Mills MT, Grafton-Clarke C, Williams G, Gosling RC, Al Baraikan A, Kyriacou AL, Morris PD, Gunn JP, Swoboda PP, Levelt E, Tsampasian V, van der Geest RJ, Swift AJ, Greenwood JP, Plein S, Vassiliou V, Garg P. Feasibility and validation of trans-valvular flow derived by four-dimensional flow cardiovascular magnetic resonance imaging in patients with atrial fibrillation. Wellcome Open Res 2021; 6:73. [PMID: 34095509 PMCID: PMC8150120 DOI: 10.12688/wellcomeopenres.16655.2] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/17/2021] [Indexed: 11/20/2022] Open
Abstract
Background: Four-dimensional (4D) flow cardiovascular magnetic resonance imaging (MRI) is an emerging technique used for intra-cardiac blood flow assessment. The role of 4D flow cardiovascular MRI in the assessment of trans-valvular flow in patients with atrial fibrillation (AF) has not previously been assessed. The purpose of this study was to assess the feasibility, image quality, and internal validity of 4D flow cardiovascular MRI in the quantification of trans-valvular flow in patients with AF. Methods: Patients with AF and healthy controls in sinus rhythm underwent cardiovascular MRI, including 4D flow studies. Quality assurance checks were done on the raw data and streamlines. Consistency was investigated by trans-valvular flow assessment between the mitral valve (MV) and the aortic valve (AV). Results: Eight patients with AF (88% male, mean age 62±13 years, mean heart rate (HR) 83±16 beats per minute (bpm)) were included and compared with ten healthy controls (70% male, mean age 41±20 years, mean HR 68.5±9 bpm). All scans were of either good quality with minimal blurring artefacts, or excellent quality with no artefacts. No significant bias was observed between the AV and MV stroke volumes in either healthy controls (-4.8, 95% CI -15.64 to 6.04; P=0.34) or in patients with AF (1.64, 95% CI -4.7 to 7.94; P=0.56). A significant correlation was demonstrated between MV and AV stroke volumes in both healthy controls (r=0.87, 95% CI 0.52 to 0.97; P=0.001) and in AF patients (r=0.82, 95% CI 0.26 to 0.97; P=0.01). Conclusions: In patients with AF, 4D flow cardiovascular MRI is feasible with good image quality, allowing for quantification of trans-valvular flow.
Collapse
Affiliation(s)
- Mark T Mills
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | | | - Gareth Williams
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Rebecca C Gosling
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Abdulaziz Al Baraikan
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Andreas L Kyriacou
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Paul D Morris
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Julian P Gunn
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Peter P Swoboda
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Eylem Levelt
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | | | - Rob J van der Geest
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Andrew J Swift
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - John P Greenwood
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Vass Vassiliou
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Pankaj Garg
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
- Norwich Medical School, University of East Anglia, Norwich, UK
| |
Collapse
|
24
|
Horowitz MJ, Kupsky DF, El-Said HG, Alshawabkeh L, Kligerman SJ, Hsiao A. 4D Flow MRI Quantification of Congenital Shunts: Comparison to Invasive Catheterization. Radiol Cardiothorac Imaging 2021; 3:e200446. [PMID: 33969306 PMCID: PMC8098085 DOI: 10.1148/ryct.2021200446] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 12/23/2020] [Accepted: 01/07/2021] [Indexed: 06/12/2023]
Abstract
PURPOSE To compare invasive right heart catheterization with four-dimensional (4D) flow MRI for estimating shunt fraction in patients with intracardiac and extracardiac shunts. MATERIALS AND METHODS In this retrospective study, patients who underwent 4D flow MRI and invasive right heart catheterization with a shunt run between August 2015 and November 2018 were included. The primary objective was comparison of estimated shunt fraction (ratio of pulmonary-to-systemic flow, Qp/Qs) at 4D flow and catheterization. Secondary objectives included comparison of the right ventricular-to-left ventricular stroke volume ratio (RVSV/LVSV) to shunt fraction (for those with applicable shunts) and comparison of cardiac output between 4D flow and catheterization. Statistical analysis included Pearson correlation and Bland-Altman plots. RESULTS A total of 33 patients met inclusion criteria (mean age, 49 years ± 16 [standard deviation]; 24 women). 4D flow measurements of Qp/Qs strongly correlated with those at catheterization (r = 0.938), and there was no bias. RVSV/LVSV correlated strongly with Qp/Qs from 4D flow (r = 0.852) and catheterization (r = 0.842). Measurements of left ventricle (Qs) and right ventricle (QP) cardiac output from 4D flow and catheterization (Fick) correlated moderately overall (r = 0.673 [Qp] and r = 0.750 [Qs]). CONCLUSION Shunt fraction measurement using 4D flow MRI compares well with that using invasive cardiac catheterization.Supplemental material is available for this article.© RSNA, 2021.
Collapse
|
25
|
Mills MT, Grafton-Clarke C, Williams G, Gosling RC, Al Baraikan A, Kyriacou AL, Morris PD, Gunn JP, Swoboda PP, Levelt E, Tsampasian V, van der Geest RJ, Swift AJ, Greenwood JP, Plein S, Vassiliou V, Garg P. Feasibility and validation of trans-valvular flow derived by four-dimensional flow cardiovascular magnetic resonance imaging in patients with atrial fibrillation. Wellcome Open Res 2021; 6:73. [PMID: 34095509 PMCID: PMC8150120 DOI: 10.12688/wellcomeopenres.16655.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/05/2021] [Indexed: 11/12/2023] Open
Abstract
Background: Four-dimensional (4D) flow cardiovascular magnetic resonance imaging (MRI) is an emerging technique used for intra-cardiac blood flow assessment. The role of 4D flow cardiovascular MRI in the assessment of trans-valvular flow in patients with atrial fibrillation (AF) has not previously been assessed. The purpose of this study was to assess the feasibility, image quality, and internal validity of 4D flow cardiovascular MRI in the quantification of trans-valvular flow in patients with AF. Methods: Patients with AF and healthy controls in sinus rhythm underwent cardiovascular MRI, including 4D flow studies. Quality assurance checks were done on the raw data and streamlines. Consistency was investigated by trans-valvular flow assessment between the mitral valve (MV) and the aortic valve (AV). Results: Eight patients with AF (88% male, mean age 62±13 years, mean heart rate (HR) 83±16 beats per minute (bpm)) were included and compared with ten healthy controls (70% male, mean age 41±20 years, mean HR 68.5±9 bpm). All scans were of either good quality with minimal blurring artefacts, or excellent quality with no artefacts. No significant bias was observed between the AV and MV stroke volumes in either healthy controls (-4.8, 95% CI -15.64 to 6.04; P=0.34) or in patients with AF (1.64, 95% CI -4.7 to 7.94; P=0.56). A significant correlation was demonstrated between MV and AV stroke volumes in both healthy controls (r=0.87, 95% CI 0.52 to 0.97; P=0.001) and in AF patients (r=0.82, 95% CI 0.26 to 0.97; P=0.01). Conclusions: In patients with AF, 4D flow cardiovascular MRI is feasible with good image quality, allowing for quantification of trans-valvular flow.
Collapse
Affiliation(s)
- Mark T Mills
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | | | - Gareth Williams
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Rebecca C Gosling
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Abdulaziz Al Baraikan
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Andreas L Kyriacou
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Paul D Morris
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Julian P Gunn
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Peter P Swoboda
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Eylem Levelt
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | | | - Rob J van der Geest
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Andrew J Swift
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - John P Greenwood
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Vass Vassiliou
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Pankaj Garg
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
- Norwich Medical School, University of East Anglia, Norwich, UK
| |
Collapse
|
26
|
Juffermans JF, Minderhoud SCS, Wittgren J, Kilburg A, Ese A, Fidock B, Zheng YC, Zhang JM, Blanken CPS, Lamb HJ, Goeman JJ, Carlsson M, Zhao S, Planken RN, van Ooij P, Zhong L, Chen X, Garg P, Emrich T, Hirsch A, Töger J, Westenberg JJM. Multicenter Consistency Assessment of Valvular Flow Quantification With Automated Valve Tracking in 4D Flow CMR. JACC Cardiovasc Imaging 2021; 14:1354-1366. [PMID: 33582060 DOI: 10.1016/j.jcmg.2020.12.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 11/18/2020] [Accepted: 12/11/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVES This study determined: 1) the interobserver agreement; 2) valvular flow variation; and 3) which variables independently predicted the variation of valvular flow quantification from 4-dimensional (4D) flow cardiac magnetic resonance (CMR) with automated retrospective valve tracking at multiple sites. BACKGROUND Automated retrospective valve tracking in 4D flow CMR allows consistent assessment of valvular flow through all intracardiac valves. However, due to the variance of CMR scanners and protocols, it remains uncertain if the published consistency holds for other clinical centers. METHODS Seven sites each retrospectively or prospectively selected 20 subjects who underwent whole heart 4D flow CMR (64 patients and 76 healthy volunteers; aged 32 years [range 24 to 48 years], 47% men, from 2014 to 2020), which was acquired with locally used CMR scanners (scanners from 3 vendors; 2 1.5-T and 5 3-T scanners) and protocols. Automated retrospective valve tracking was locally performed at each site to quantify the valvular flow and repeated by 1 central site. Interobserver agreement was evaluated with intraclass correlation coefficients (ICCs). Net forward volume (NFV) consistency among the valves was evaluated by calculating the intervalvular variation. Multiple regression analysis was performed to assess the predicting effect of local CMR scanners and protocols on the intervalvular inconsistency. RESULTS The interobserver analysis demonstrated strong-to-excellent agreement for NFV (ICC: 0.85 to 0.96) and moderate-to-excellent agreement for regurgitation fraction (ICC: 0.53 to 0.97) for all sites and valves. In addition, all observers established a low intervalvular variation (≤10.5%) in their analysis. The availability of 2 cine images per valve for valve tracking compared with 1 cine image predicted a decreasing variation in NFV among the 4 valves (beta = -1.3; p = 0.01). CONCLUSIONS Independently of locally used CMR scanners and protocols, valvular flow quantification can be performed consistently with automated retrospective valve tracking in 4D flow CMR.
Collapse
Affiliation(s)
- Joe F Juffermans
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands.
| | - Savine C S Minderhoud
- Department of Cardiology and Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Johan Wittgren
- Department of Clinical Sciences Lund, Clinical Physiology, Lund University, Skane University Hospital, Lund, Sweden
| | - Anton Kilburg
- Department of Radiology, University Medical Center Mainz, Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Amir Ese
- Department of Radiology, University Medical Center Mainz, Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Benjamin Fidock
- Department of Infection, Immunity, and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Yu-Cong Zheng
- Department of MRI, Fuwai Hospital, National Center of Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jun-Mei Zhang
- National Heart Centre Singapore; Duke-NUS Medical School Singapore, National University of Singapore, Singapore
| | - Carmen P S Blanken
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, the Netherlands
| | - Hildo J Lamb
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Jelle J Goeman
- Department of Biomedical Data Sciences, Leiden University Medical Center, Leiden, the Netherlands
| | - Marcus Carlsson
- Department of Clinical Sciences Lund, Clinical Physiology, Lund University, Skane University Hospital, Lund, Sweden
| | - Shihua Zhao
- Department of MRI, Fuwai Hospital, National Center of Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - R Nils Planken
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, the Netherlands
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, the Netherlands
| | - Liang Zhong
- National Heart Centre Singapore; Duke-NUS Medical School Singapore, National University of Singapore, Singapore
| | - Xiuyu Chen
- Department of MRI, Fuwai Hospital, National Center of Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Pankaj Garg
- Department of Infection, Immunity, and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Tilman Emrich
- Department of Radiology, University Medical Center Mainz, Johannes Gutenberg-University Mainz, Mainz, Germany; German Center for Cardiovascular Research (DZHK), partner site Rhine-Main, Mainz, Germany
| | - Alexander Hirsch
- Department of Cardiology and Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Johannes Töger
- Department of Clinical Sciences Lund, Clinical Physiology, Lund University, Skane University Hospital, Lund, Sweden
| | - Jos J M Westenberg
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
27
|
Intracardiac and Vascular Hemodynamics with Cardiovascular Magnetic Resonance in Heart Failure. Heart Fail Clin 2021; 17:135-147. [PMID: 33220882 DOI: 10.1016/j.hfc.2020.08.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In heart failure (HF), the impaired heart loses its ability to competently eject blood during systole or fill with blood during diastole, manifesting in multifaceted abnormal intracardiac or intravascular flow dynamics. Conventional imaging techniques are limited in their ability to evaluate multidirectional multidimensional flow alterations in HF. Four-dimensional (4-D) flow magnetic resonance imaging (MRI) has emerged as a promising technique to comprehensively visualize and quantify changes in 3-dimensional blood flow dynamics in complex cardiovascular diseases. This article reviews emerging applications of 4-D flow MRI hemodynamic markers in HF and etiologies at risk of progressing to HF.
Collapse
|
28
|
Gajjar K, Kashyap K, Badlani J, Williams RB, Biederman RWW. A review of the pivotal role of cardiac MRI in mitral valve regurgitation. Echocardiography 2020; 38:128-141. [PMID: 33270944 DOI: 10.1111/echo.14941] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 11/09/2020] [Accepted: 11/11/2020] [Indexed: 01/21/2023] Open
Abstract
Cardiac imaging is the cornerstone of defining the etiology, quantification, and management of mitral regurgitation (MR). This continues to be even more so the case with emerging transcatheter techniques to manage MR. Transthoracic echocardiography remains the first-line imaging modality to assess MR but has limitations. Cardiac MRI(CMR) provides the advantages of quantitative nonvisual estimation, 3D volumetric data, late gadolinium, T1, and extracellular volume measurements to comprehensively assess mitral valvular pathology, cardiac remodeling, and the prognostic impact of therapies. This review describes the superiority, technical aspects and growing evidence behind CMR, and lays the roadmap for the future of CMR in MR.
Collapse
Affiliation(s)
- Kushani Gajjar
- Department of Cardiology, Allegheny General Hospital- Allegheny Health Network, Pittsburgh, PA, USA
| | - Kartikeya Kashyap
- Department of Cardiology, Allegheny General Hospital- Allegheny Health Network, Pittsburgh, PA, USA
| | - Jayshiv Badlani
- Department of Cardiovascular Magnetic Resonance Imaging, Allegheny General Hospital- Allegheny Health Network, Pittsburgh, PA, USA
| | - Ronald B Williams
- Department of Cardiovascular Magnetic Resonance Imaging, Allegheny General Hospital- Allegheny Health Network, Pittsburgh, PA, USA
| | - Robert W W Biederman
- Department of Cardiology, Allegheny General Hospital- Allegheny Health Network, Pittsburgh, PA, USA.,Department of Cardiovascular Magnetic Resonance Imaging, Allegheny General Hospital- Allegheny Health Network, Pittsburgh, PA, USA.,Drexel University, Philadelphia, PA, USA.,Bioengineering Department, Carnegie Mellon University, Pittsburgh, PA, USA
| |
Collapse
|
29
|
Lee J, El Hangouche N, Gupta AN, Markl M, Kim S, Wilcox J, Thomas JD. Complicated Double-Orifice Mitral Regurgitation: Combined Hemodynamic Assessment Using Echocardiography and Four-Dimensional Flow Magnetic Resonance Imaging. CASE 2020; 4:494-499. [PMID: 33376841 PMCID: PMC7756160 DOI: 10.1016/j.case.2020.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
Angle correction may be needed when PISA is applied to a near commissural MR jet. Four-dimensional flow MRI enabled MR volume quantification with 3D jet visualization. Exercise-induced VT may have complex structural, genetic, and ECG etiologies.
Collapse
|
30
|
Pathrose A, Ma L, Berhane H, Scott MB, Chow K, Forman C, Jin N, Serhal A, Avery R, Carr J, Markl M. Highly accelerated aortic 4D flow MRI using compressed sensing: Performance at different acceleration factors in patients with aortic disease. Magn Reson Med 2020; 85:2174-2187. [PMID: 33107141 DOI: 10.1002/mrm.28561] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 09/29/2020] [Accepted: 09/30/2020] [Indexed: 12/16/2022]
Abstract
PURPOSE To systematically assess the feasibility and performance of a highly accelerated compressed sensing (CS) 4D flow MRI framework at three different acceleration factors (R) for the quantification of aortic flow dynamics and wall shear stress (WSS) in patients with aortic disease. METHODS Twenty patients with aortic disease (58 ± 15 y old; 19 M) underwent four 4D flow scans: one conventional (GRAPPA, R = 2) and three CS 4D flows with R = 5.7, 7.7, and 10.2. All scans were acquired with otherwise equivalent imaging parameters on a 1.5T scanner. Peak-systolic velocity (Vmax ), peak flow (Qmax ), and net flow (Qnet ) were quantified at the ascending aorta (AAo), arch, and descending aorta (DAo). WSS was calculated at six regions within the AAo and arch. RESULTS Mean scan times for the conventional and CS 4D flows with R = 5.7, 7.7, and 10.2 were 9:58 ± 2:58 min, 3:40 ± 1:19 min, 2:50 ± 0:56 min, and 2:05 ± 0:42 min, respectively. Vmax , Qmax , and Qnet were significantly underestimated by all CS protocols (underestimation ≤ -7%, -9%, and -10% by CS, R = 5.7, 7.7, and 10.2, respectively). WSS measurements showed the highest underestimation by all CS protocols (underestimation ≤ -9%, -12%, and -14% by CS, R = 5.7, 7.7, and 10.2). CONCLUSIONS Highly accelerated aortic CS 4D flow at R = 5.7, 7.7, and 10.2 showed moderate agreement with the conventional 4D flow, despite systematically underestimating various hemodynamic parameters. The shortened scan time may enable the clinical translation of CS 4D flow, although potential hemodynamic underestimation should be considered when interpreting the results.
Collapse
Affiliation(s)
- Ashitha Pathrose
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Liliana Ma
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| | - Haben Berhane
- Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois, USA
| | - Michael B Scott
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| | - Kelvin Chow
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, Illinois, USA
| | | | - Ning Jin
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, Illinois, USA
| | - Ali Serhal
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Ryan Avery
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - James Carr
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| |
Collapse
|
31
|
Corrias G, Cocco D, Suri JS, Meloni L, Cademartiri F, Saba L. Heart applications of 4D flow. Cardiovasc Diagn Ther 2020; 10:1140-1149. [PMID: 32968665 DOI: 10.21037/cdt.2020.02.08] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Four-dimensional (4D) flow sequences are an innovative type of MR sequences based upon phase contrast (PC) sequences which are a type of application of Angio-MRI together with the Time of Flight (TOF) sequences and Contrast-Enhanced Magnetic Resonance Acquisition (CE-MRA). They share the basic principles of PC, but unlike PC sequences, 4D flow has velocity encoding along all three flow directions and three-dimensional (3D) anatomic coverage. They guarantee the analysis of flow with multiplanarity on a post-processing level, which is a unique feature among MR sequences. Furthermore, this technique provides a completely new level to the in vivo flow analysis as it allows measurements in never studied districts such as intracranial applications or some parts of the heart never studied with echo-color-doppler, which is its sonographic equivalent. Furthermore, this technique provides a completely new level to the in vivo flow analysis as it allows accurate measurement of the flows in different districts (e.g., intracranial, cardiac) that are usually studied with echo-color-doppler, which is its sonographic equivalent. Of note, the technique has proved to be affected by less inter and intra-observer variability in several application. 4D-flow basic principles, advantages, limitations, common pitfalls and artefacts are described. This review will outline the basis of the formation of PC image, the construction of a 4D-flow and the huge impact the technique is having on the cardiovascular non-invasive examination. It will be then studied how this technique has had a huge impact on cardiovascular examinations especially on a central heart level.
Collapse
Affiliation(s)
- Giuseppe Corrias
- Department of Radiology, University of Cagliari, Cagliari, Italy
| | - Daniele Cocco
- Department of Cardiology, University of Cagliari, Cagliari, Italy
| | - Jasjit S Suri
- Monitoring and Diagnostic Division, Atheropoint, Roseville, CA, USA.,Department of Electrical Engineering, University of Idaho, Hagerman, ID, USA
| | - Luigi Meloni
- Department of Cardiology, University of Cagliari, Cagliari, Italy
| | - Filippo Cademartiri
- Department of Radiology, Erasmus Medical Center University, Rotterdam, The Netherlands
| | - Luca Saba
- Department of Radiology, University of Cagliari, Cagliari, Italy
| |
Collapse
|
32
|
Catapano F, Pambianchi G, Cundari G, Rebelo J, Cilia F, Carbone I, Catalano C, Francone M, Galea N. 4D flow imaging of the thoracic aorta: is there an added clinical value? Cardiovasc Diagn Ther 2020; 10:1068-1089. [PMID: 32968661 DOI: 10.21037/cdt-20-452] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Four-dimensional (4D) flow MRI has emerged as a powerful non-invasive technique in cardiovascular imaging, enabling to analyse in vivo complex flow dynamics models by quantifying flow parameters and derived features. Deep knowledge of aortic flow dynamics is fundamental to better understand how abnormal flow patterns may promote or worsen vascular diseases. In the perspective of an increasingly personalized and preventive medicine, growing interest is focused on identifying those quantitative functional features which are early predictive markers of pathological evolution. The thoracic aorta and its spectrum of diseases, as the first area of application and development of 4D flow MRI and supported by an extensive experimental validation, represents the ideal model to introduce this technique into daily clinical practice. The purpose of this review is to describe the impact of 4D flow MRI in the assessment of the thoracic aorta and its most common affecting diseases, providing an overview of the actual clinical applications and describing the potential role of derived advanced hemodynamic measures in tailoring follow-up and treatment.
Collapse
Affiliation(s)
- Federica Catapano
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Giacomo Pambianchi
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Giulia Cundari
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - João Rebelo
- Department of Radiology, Centro Hospitalar São João, Alameda Prof. Hernâni Monteiro, Porto, Portugal
| | - Francesco Cilia
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Iacopo Carbone
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Carlo Catalano
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Marco Francone
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Nicola Galea
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy.,Department of Experimental Medicine, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
33
|
Saunderson CED, Paton MF, Chowdhary A, Brown LAE, Gierula J, Sengupta A, Kelly C, Chew PG, Das A, Craven TP, van der Geest RJ, Higgins DM, Zhong L, Witte KK, Greenwood JP, Plein S, Garg P, Swoboda PP. Feasibility and validation of trans-valvular flow derived by four-dimensional flow cardiovascular magnetic resonance imaging in pacemaker recipients. Magn Reson Imaging 2020; 74:46-55. [PMID: 32889092 PMCID: PMC7674584 DOI: 10.1016/j.mri.2020.08.024] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 08/26/2020] [Accepted: 08/27/2020] [Indexed: 02/09/2023]
Affiliation(s)
- Christopher E D Saunderson
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - Maria F Paton
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - Amrit Chowdhary
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - Louise A E Brown
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - John Gierula
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - Anshuman Sengupta
- Department of Cardiology, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Christopher Kelly
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - Pei G Chew
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - Arka Das
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - Thomas P Craven
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - Rob J van der Geest
- Division of Image Processing, Leiden University Medical Centre, Leiden, the Netherlands
| | | | - Liang Zhong
- National Heart Research Institute Singapore, National Heart Centre Singapore, Duke-NUS Medical School, National University of Singapore, Singapore
| | - Klaus K Witte
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - John P Greenwood
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - Sven Plein
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK
| | - Pankaj Garg
- Academic Radiology, Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Peter P Swoboda
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, and Leeds Teaching Hospitals NHS Trust, UK.
| |
Collapse
|
34
|
Jacobs K, Rigdon J, Chan F, Cheng JY, Alley MT, Vasanawala S, Maskatia SA. Direct measurement of atrioventricular valve regurgitant jets using 4D flow cardiovascular magnetic resonance is accurate and reliable for children with congenital heart disease: a retrospective cohort study. J Cardiovasc Magn Reson 2020; 22:33. [PMID: 32404159 PMCID: PMC7222506 DOI: 10.1186/s12968-020-00612-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Accepted: 03/02/2020] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND 3D-time resolved flow (4DF) cardiovascular magnetic resonance (CMR) with retrospective analysis of atrioventricular valve regurgitation (AVVR) allows for internal validation by multiple direct and indirect methods. Limited data exist on direct measurement of AVVR by 4DF CMR in pediatric congenital heart disease (CHD). We aimed to validate direct measurement of the AVVR jet as accurate and reliable compared to the volumetric method (clinical standard by 2D CMR) and as a superior method of internal validation than the annular inflow method. METHODS We identified 44 consecutive patients with diverse CHD referred for evaluation of AVVR by CMR. 1.5 T or 3 T scanners, intravenous contrast, and a combination of parallel imaging and compressed sensing were used. Four methods of measuring AVVR volume (RVol) were used: volumetric method (VOL; the clinical standard) = stroke volume by 2D balanced steady-state free precession - semilunar valve forward flow (SLFF); annular inflow method (AIM) = atrioventricular valve forward flow [AVFF] - semilunar valve net flow (SLNF); and direct measurement (JET). AVFF was measured using static and retrospective valve tracking planes. SLFF, SLNF, AVFF, and JET were measured by 4DF phase contrast. Regurgitant fraction was calculated as [RVol/(RVol+SLNF)]× 100. Statistical methods included Spearman, Wilcoxon rank sum test/Student paired t-test, Bland Altman analysis, and intra-class coefficient (ICC), where appropriate. RESULTS Regurgitant fraction by JET strongly correlated with the indirect methods (VOL and AIM) (ρ = 0.73-0.80, p < 0.001) and was similar to VOL with a median difference (interquartile range) of - 1.5% (- 8.3-7.2%; p = 0.624). VOL had weaker correlations with AIM and JET (ρ = 0.69-0.73, p < 0.001). AIM underestimated RF by 3.6-6.9% compared to VOL and JET, p < 0.03. Intra- and inter- observer reliability were excellent for all methods (ICC 0.94-0.99). The mean (±standard deviation) inter-observer difference for VOL was 2.4% (±5.1%), p < 0.05. CONCLUSIONS In a diverse cohort of pediatric CHD, measurement of AVVR using JET is accurate and reliable to VOL and is a superior method of internal validation compared to AIM. This study supports use of 4DF CMR for measurement of AVVR, obviating need for expert prospective prescription during image acquisition by 2D CMR.
Collapse
Affiliation(s)
- Kimberley Jacobs
- Department of Pediatrics, Stanford University School of Medicine, 725 Welch Rd, Room G71, MC 5906, Palo Alto, CA, 94304, USA.
| | - Joseph Rigdon
- Department of Medicine, Quantitative Sciences Unit, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| | - Frandics Chan
- Department of Radiology, Divisions of Pediatric Radiology and Cardiovascular Imaging, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| | - Joseph Y Cheng
- Department of Radiology, Divisions of Pediatric Radiology and Cardiovascular Imaging, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| | - Marcus T Alley
- Department of Radiology, Divisions of Pediatric Radiology and Cardiovascular Imaging, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| | - Shreyas Vasanawala
- Department of Radiology, Divisions of Pediatric Radiology and Cardiovascular Imaging, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| | - Shiraz A Maskatia
- Department of Pediatrics, Divisions of Pediatric Cardiology and Cardiovascular Imaging, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| |
Collapse
|
35
|
Alvarez A, Martinez V, Pizarro G, Recio M, Cabrera JÁ. Clinical use of 4D flow MRI for quantification of aortic regurgitation. Open Heart 2020; 7:e001158. [PMID: 32153789 PMCID: PMC7046971 DOI: 10.1136/openhrt-2019-001158] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 12/27/2019] [Accepted: 01/07/2020] [Indexed: 12/20/2022] Open
Abstract
Objective The main objective of the present study was to compare the use of four-dimensional (4D) flow MRI with the habitual sequence (two-dimensional phase-contrast (2DPC) MRI) for the assessment of aortic regurgitation (AR) in the clinical routine. Methods This was a retrospective, observational cohort study of patients with varying grades of AR. For the purposes of the present study, we selected all the cases with a regurgitant fraction (RF)>5% as determined by 2DPC MRI (n=34). In all cases, both sequences (2DPC and 4D flow MRI) were acquired in a single session to ensure comparability. We compared the results of the two techniques by evaluating forward flow, regurgitant flow and regurgitation fraction. Then, the patients were divided into subgroups to determine if these factors had any influence on the measurements: aortic diameter (≤ vs >38 mm), valve anatomy (tricuspid vs bicuspid/quadricuspid), stenosis (gradient ≥15 vs <15) and region of interest location (aortic valve vs sinotubular junction). Results No statistically significant differences were observed between the two techniques with Pearson’s correlation coefficients (r) of forward flow (r=0.826/p value<0001), regurgitant flow (r=0.866/p value<0001) and RF (r=0.761/p value<0001). Conclusions The findings of this study confirm the value of 4D flow MRI for grading AR in clinical practice with an excellent correlation with the standard technique (2DPC MRI).
Collapse
Affiliation(s)
- Ana Alvarez
- Imaging Department, Hospital Universitario Quironsalud Madrid, Madrid, Spain.,Universidad Europea de Madrid, Madrid, Spain
| | - Vicente Martinez
- Imaging Department, Hospital Universitario Quironsalud Madrid, Madrid, Spain
| | - Gonzalo Pizarro
- Universidad Europea de Madrid, Madrid, Spain.,Department of Cardiology, Complejo Hospitalario Ruber Juan Bravo, Madrid, Spain
| | - Manuel Recio
- Imaging Department, Hospital Universitario Quironsalud Madrid, Madrid, Spain
| | - Jose Ángel Cabrera
- Department of Cardiology, Hospital Universitario Quironsalud Madrid, Madrid, Madrid, Spain
| |
Collapse
|
36
|
Jacobs KG, Chan FP, Cheng JY, Vasanawala SS, Maskatia SA. 4D flow vs. 2D cardiac MRI for the evaluation of pulmonary regurgitation and ventricular volume in repaired tetralogy of Fallot: a retrospective case control study. Int J Cardiovasc Imaging 2020; 36:657-669. [PMID: 31894524 DOI: 10.1007/s10554-019-01751-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 12/14/2019] [Indexed: 11/26/2022]
Abstract
Lengthy exams and breath-holding limit the use of pediatric cardiac MRI (CMR). 3D time-resolved flow MRI (4DF) is a free-breathing, single-sequence exam that obtains magnitude (anatomic) and phase contrast (PC) data. We compare the accuracy of gadobenate dimeglumine-enhanced 4DF on a 1.5 T magnet to 2D CMR in children with repaired tetralogy of Fallot (rTOF) to measure pulmonary net flow (PNF) as a reflection of pulmonary regurgitation, forward flow (FF) and ventricular volumetry. Thirty-four consecutive cases were included. 2D PCs were obtained at the valve level. Using 4DF, we measured PNF at the valve and at the main and branch pulmonary arteries. PNF measured at the valve by 4DF demonstrated the strongest correlation (r = 0.87, p < 0.001) and lowest mean difference (3.5 ± 9.4 mL/beat) to aortic net flow (ANF). Semilunar FF and stroke volume of the respective ventricle demonstrated moderate-strong correlation by 4DF (r = 0.66-0.81, p < 0.001) and strong correlation by 2D (r = 0.81-0.84, p < 0.001) with similar correlations and mean differences between techniques (p > 0.05). Ventricular volumes correlated strongly between 2D and 4DF (r = 0.75-0.96, p < 0.001), though 4DF overestimated right ventricle volumes by 11.8-19.2 mL/beat. Inter-rater reliability was excellent for 2D and 4DF volumetry (ICC = 0.91-0.99). Ejection fraction moderately correlated (r = 0.60-0.75, p < 0.001) with better reliability by 4DF (ICC: 0.80-0.85) than 2D (ICC: 0.69-0.89). 4DF exams were shorter than 2D (9 vs. 71 min, p < 0.001). 4DF provides highly reproducible and accurate measurements of flow with slight overestimation of RV volumes compared to 2D in pediatric rTOF. 4DF offers important advantages in this population with long-term monitoring needs.
Collapse
Affiliation(s)
- Kimberley G Jacobs
- Department of Pediatrics, Stanford University School of Medicine, Palo Alto, CA, USA.
- Lucile Packard Children's Hospital, 725 Welch Rd, Room G71, MC 5906, Palo Alto, CA, 94304, USA.
| | - Frandics P Chan
- Department of Pediatrics, Stanford University School of Medicine, Palo Alto, CA, USA
| | - Joseph Y Cheng
- Department of Pediatrics, Stanford University School of Medicine, Palo Alto, CA, USA
| | - Shreyas S Vasanawala
- Divisions of Pediatric Radiology and Cardiovascular Imaging, Department of Radiology, Stanford University School of Medicine, Palo Alto, CA, USA
| | - Shiraz A Maskatia
- Department of Pediatrics, Stanford University School of Medicine, Palo Alto, CA, USA
- Divisions of Pediatric Cardiology and Cardiovascular Imaging, Department of Pediatrics, Stanford University School of Medicine, Palo Alto, CA, USA
| |
Collapse
|
37
|
Warmerdam E, Krings GJ, Leiner T, Grotenhuis HB. Three-dimensional and four-dimensional flow assessment in congenital heart disease. Heart 2019; 106:421-426. [PMID: 31857355 DOI: 10.1136/heartjnl-2019-315797] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Revised: 11/08/2019] [Accepted: 11/20/2019] [Indexed: 01/27/2023] Open
Abstract
Congenital heart disease (CHD) is the most common form of congenital defects, with an incidence of 8 per 1000 births. Due to major advances in diagnostics, perioperative care and surgical techniques, the survival rate of patients with CHD has improved dramatically. Conversely, although 70%-95% of infants with CHD survive into adulthood, the rate of long-term morbidity, which often requires (repeat) intervention, has increased. Recently, the role of altered haemodynamics in cardiac development and CHD has become a subject of interest. Patients with CHD often have abnormal blood flow patterns, either due to the primary cardiac defect or as a consequence of the surgical intervention(s). Research suggests that these abnormal blood flow patterns may contribute to diminished cardiac and vascular function. Serial assessment of haemodynamic parameters in patients with CHD may allow for improved understanding of the often complex haemodynamics in these patients and thereby potentially guide the timing and nature of interventions with the aim of preventing progression of cardiovascular deterioration. In this article we will discuss two novel non-invasive four-dimensional (4D) techniques to evaluate cardiovascular haemodynamics: 4D-flow cardiac magnetic resonance and computational fluid dynamics. This review focuses on the additional value of these two modalities in the evaluation of patients with CHD with abnormal flow patterns, who could benefit from advanced haemodynamic evaluation: patients with coarctation of the aorta, bicuspid aortic valve, tetralogy of Fallot and patients after Fontan palliation.
Collapse
Affiliation(s)
- Evangeline Warmerdam
- Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands.,Pediatric Cardiology, Wilhelmina Children's Hospital University Medical Center, Utrecht, The Netherlands
| | - Gregor J Krings
- Pediatric Cardiology, Wilhelmina Children's Hospital University Medical Center, Utrecht, The Netherlands
| | - Tim Leiner
- Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Heynric B Grotenhuis
- Pediatric Cardiology, Wilhelmina Children's Hospital University Medical Center, Utrecht, The Netherlands .,Pediatric Cardiology, Universitair Medisch Centrum Utrecht - Locatie Wilhelmina Kinderziekenhuis, Utrecht, The Netherlands
| |
Collapse
|
38
|
Abstract
Mitral regurgitation (MR) is a common valvular heart disease and is the second most frequent indication for heart valve surgery in Western countries. Echocardiography is the recommended first-line test for the assessment of valvular heart disease, but cardiovascular magnetic resonance imaging (CMR) provides complementary information, especially for assessing MR severity and to plan the timing of intervention. As new CMR techniques for the assessment of MR have arisen, standardizing CMR protocols for research and clinical studies has become important in order to optimize diagnostic utility and support the wider use of CMR for the clinical assessment of MR. In this Consensus Statement, we provide a detailed description of the current evidence on the use of CMR for MR assessment, highlight its current clinical utility, and recommend a standardized CMR protocol and report for MR assessment. In this Consensus Statement, Garg and colleagues describe the current evidence on the use of cardiovascular magnetic resonance imaging for the assessment of mitral regurgitation, highlight its current clinical utility, and recommend a standardized imaging protocol and report.
Collapse
|
39
|
Peper ES, Leopaldi AM, van Tuijl S, Coolen BF, Strijkers GJ, Baan J, Planken RN, de Weger A, Nederveen AJ, Marquering HA, van Ooij P. An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study. Eur Radiol Exp 2019; 3:40. [PMID: 31650367 PMCID: PMC6813403 DOI: 10.1186/s41747-019-0114-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 07/02/2019] [Indexed: 12/25/2022] Open
Abstract
Background Cardiac magnetic resonance imaging (MRI) in large animals is cumbersome for various reasons, including ethical considerations, costs of housing and maintenance, and need for anaesthesia. Our primary purpose was to show the feasibility of an isolated beating pig heart model for four-dimensional (4D) flow MRI for investigating intracardiac blood flow patterns and flow parameters using slaughterhouse side products. In addition, the feasibility of evaluating transcatheter aortic valve replacement (TAVR) in the model was investigated. Methods Seven slaughterhouse pig hearts were installed in the MRI-compatible isolated beating pig heart platform. First, Langendorff perfusion mode was established; then, the system switched to working mode, in which blood was actively pumped by the left ventricle. A pacemaker ensured a stable HR during 3-T MRI scanning. All hearts were submitted to human physiological conditions of cardiac output and stayed vital for several hours. Aortic flow was measured from which stroke volume, cardiac output, and regurgitation fraction were calculated. Results 4D flow MRI acquisitions were successfully conducted in all hearts. Stroke volume was 31 ± 6 mL (mean ± standard deviation), cardiac output 3.3 ± 0.9 L/min, and regurgitation fraction 16% ± 9%. With 4D flow, intracardiac and coronary flow patterns could be visualised in all hearts. In addition, we could study valve function and regurgitation in two hearts after TAVR. Conclusions The feasibility of 4D flow MRI in an isolated beating pig heart loaded to physiological conditions was demonstrated. The platform is promising for preclinical assessment of cardiac blood flow and function. Electronic supplementary material The online version of this article (10.1186/s41747-019-0114-5) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Eva S Peper
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
| | | | | | - Bram F Coolen
- Department of Biomedical Engineering & Physics, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Gustav J Strijkers
- Department of Biomedical Engineering & Physics, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Jan Baan
- Department of Cardiology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - R Nils Planken
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Arend de Weger
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - Aart J Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Henk A Marquering
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.,Department of Biomedical Engineering & Physics, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
40
|
Isorni MA, Martins D, Ben Moussa N, Monnot S, Boddaert N, Bonnet D, Hascoet S, Raimondi F. 4D flow MRI versus conventional 2D for measuring pulmonary flow after Tetralogy of Fallot repair. Int J Cardiol 2019; 300:132-136. [PMID: 31676117 DOI: 10.1016/j.ijcard.2019.10.030] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Revised: 09/20/2019] [Accepted: 10/18/2019] [Indexed: 10/25/2022]
Abstract
BACKGROUND After tetralogy of Fallot (TOF) repair, pulmonary regurgitation and right ventricular function must be monitored. Conventional (2D) cardiac magnetic resonance (CMR) is currently the clinical reference method for measuring pulmonary regurgitation. However, 4DFlow CMR has been reported to provide a more comprehensive flow analysis than 2D CMR. We aimed to compare 4DFlow CMR to 2D CMR for assessing pulmonary regurgitation and flow, as well as aortic flow, in children and adults after surgical repair of TOF. METHODS Retrospective analysis of patients with repaired TOF admitted for cardiac MRI with 4DFlow acquisition from 2016 to 2018. Linear regression was used to assess correlations and Bland-Altman analyses were performed. RESULTS The 60 included patients had a mean age of 18.2 ± 10.4 years (range, 2-54 years). Significant correlations between the two techniques were found for pulmonary regurgitant fraction (R [2] = 0.6642, p < 0.0001), net pulmonary flow (R [2] = 0.6782, p < 0.0001), forward pulmonary flow (R [2] = 0.6185, p < 0.0001), backward pulmonary flow (R [2] = 0.8192, p < 0.0001), and aortic valve flow (R [2] = 0.6494, p < 0.0001). The Bland-Altman analysis showed no significant bias, narrow limits of agreement, and few scattered points. The correlation between pulmonary and aortic flow was better with 4DFlow CMR than with 2D CMR (R [2] = 0.8564, p < 0.0001 versus R [2] = 0.4393, p < 0,0001, respectively). Interobserver reliability was good. CONCLUSION These results establish the feasibility and reliability of 4DFlow CMR for assessing pulmonary flow in a large paediatric and adult population with repaired TOF. 4DFlow CMR may be more reliable than 2D MRI for pulmonary flow assessment after TOF repair.
Collapse
Affiliation(s)
- M A Isorni
- Unité de radiologie diagnostique et thérapeutique, Hôpital Marie Lannelongue, 133, avenue de la résistance, 92350, Le Plessis Robinson, France
| | - D Martins
- Unité médicochirurgicale de cardiologie congénitale et pédiatrique, centre de référence des maladies cardiaques congénitales complexes - M3C, Hôpital universitaire Necker-Enfants-Malades, 149, rue de Sèvres, 75743, Paris, Cedex 15, France; Pediatric Cardiology Unit, Hospital de Santa Cruz, Lisboa, Portugal
| | - N Ben Moussa
- Unité de radiologie diagnostique et thérapeutique, Hôpital Marie Lannelongue, 133, avenue de la résistance, 92350, Le Plessis Robinson, France
| | - S Monnot
- Unité de radiologie diagnostique et thérapeutique, Hôpital Marie Lannelongue, 133, avenue de la résistance, 92350, Le Plessis Robinson, France
| | - N Boddaert
- Pediatric Radiology Unit, Hôpital universitaire Necker-Enfants-Malades, 149, rue de Sèvres, 75743, Paris, Cedex 15, France
| | - D Bonnet
- Unité médicochirurgicale de cardiologie congénitale et pédiatrique, centre de référence des maladies cardiaques congénitales complexes - M3C, Hôpital universitaire Necker-Enfants-Malades, 149, rue de Sèvres, 75743, Paris, Cedex 15, France
| | - S Hascoet
- Unité de radiologie diagnostique et thérapeutique, Hôpital Marie Lannelongue, 133, avenue de la résistance, 92350, Le Plessis Robinson, France
| | - F Raimondi
- Unité médicochirurgicale de cardiologie congénitale et pédiatrique, centre de référence des maladies cardiaques congénitales complexes - M3C, Hôpital universitaire Necker-Enfants-Malades, 149, rue de Sèvres, 75743, Paris, Cedex 15, France; Pediatric Radiology Unit, Hôpital universitaire Necker-Enfants-Malades, 149, rue de Sèvres, 75743, Paris, Cedex 15, France.
| |
Collapse
|
41
|
Blanken CPS, Farag ES, Boekholdt SM, Leiner T, Kluin J, Nederveen AJ, van Ooij P, Planken RN. Advanced cardiac MRI techniques for evaluation of left-sided valvular heart disease. J Magn Reson Imaging 2019; 48:318-329. [PMID: 30134000 PMCID: PMC6667896 DOI: 10.1002/jmri.26204] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Accepted: 04/19/2018] [Indexed: 01/06/2023] Open
Abstract
The most common types of left‐sided valvular heart disease (VHD) in the Western world are aortic valve stenosis, aortic valve regurgitation, and mitral valve regurgitation. Comprehensive clinical evaluation entails both hemodynamic analysis and structural as well as functional characterization of the left ventricle. Cardiac magnetic resonance imaging (MRI) is an established diagnostic modality for assessment of left‐sided VHD and is progressively gaining ground in modern‐day clinical practice. Detailed flow visualization and quantification of flow‐related biomarkers in VHD can be obtained using 4D flow MRI, an imaging technique capable of measuring blood flow in three orthogonal directions over time. In addition, recent MRI sequences enable myocardial tissue characterization and strain analysis. In this review we discuss the emerging potential of state‐of‐the‐art MRI including 4D flow MRI, tissue mapping, and strain quantification for the diagnosis and prognosis of left‐sided VHD. Level of Evidence: 1 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2018. J. MAGN. RESON. IMAGING 2018;48:318–329.
Collapse
Affiliation(s)
- Carmen P S Blanken
- Department of Radiology and Nuclear Medicine, Academic Medical Center, Amsterdam, the Netherlands
| | - Emile S Farag
- Department of Cardiothoracic Surgery, Academic Medical Center, Amsterdam, the Netherlands
| | | | - Tim Leiner
- Department of Radiology, University Medical Center, Utrecht, the Netherlands
| | - Jolanda Kluin
- Department of Cardiothoracic Surgery, Academic Medical Center, Amsterdam, the Netherlands
| | - Aart J Nederveen
- Department of Radiology and Nuclear Medicine, Academic Medical Center, Amsterdam, the Netherlands
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Academic Medical Center, Amsterdam, the Netherlands
| | - R Nils Planken
- Department of Radiology and Nuclear Medicine, Academic Medical Center, Amsterdam, the Netherlands
| |
Collapse
|
42
|
|
43
|
Fidock B, Barker N, Balasubramanian N, Archer G, Fent G, Al-Mohammad A, Richardson J, O'Toole L, Briffa N, Rothman A, van der Geest R, Hose R, Wild JM, Swift AJ, Garg P. A Systematic Review of 4D-Flow MRI Derived Mitral Regurgitation Quantification Methods. Front Cardiovasc Med 2019; 6:103. [PMID: 31428619 PMCID: PMC6688118 DOI: 10.3389/fcvm.2019.00103] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2019] [Accepted: 07/15/2019] [Indexed: 11/24/2022] Open
Abstract
Background: Four-dimensional flow cardiac magnetic resonance (4D flow CMR) is an emerging non-invasive imaging technology that can be used to quantify mitral regurgitation (MR) volume. Current methods of quantification have demonstrated limitations in accurate analysis, particularly in difficult cases such as complex congenital heart disease. 4D flow CMR methods aim to circumvent these limitations and allow accurate quantification of MR volume even in complex cases. This systematic review aims to summarize the available literature on 4D flow CMR MR quantification methods and examine their ability to accurately classify MR severity. Methods: Structured searches were carried out on Medline and EMBASE in December 2018 to identify suitable research outcome studies. The titles and abstracts were screened for relevance, with a third adjudicator utilized when study suitability was uncertain. Results: Seven studies met the eligibility criteria and were included in the systematic review. The most widely used 4D flow MRI method was retrospective valve tracking (RVT) which was examined in five papers. The key finding of these papers was that RVT is a reliable and accurate method of regurgitant volume quantification. Conclusions: MR quantification through 4D flow MRI is both feasible and accurate. The evidence gathered suggests that for MR assessment, 4D flow MRI is potentially as accurate and reliable to echocardiography and may be complementary to this technique. Further work on MR quantification 4D flow image analysis is needed to determine the most accurate analysis technique and to demonstrate 4D flow MRI as a predictor of clinical outcome. PROSPERO Registration Number: CRD42019122837, http://www.crd.york.ac.uk/PROSPERO/display_record.php?ID=CRD42019122837
Collapse
Affiliation(s)
- Benjamin Fidock
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Natasha Barker
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Nithin Balasubramanian
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Gareth Archer
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Graham Fent
- Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom
| | | | - James Richardson
- Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom
| | - Laurence O'Toole
- Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom
| | - Norman Briffa
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.,Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom
| | - Alexander Rothman
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | | | - Rod Hose
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - James M Wild
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Andrew J Swift
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Pankaj Garg
- Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.,Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom
| |
Collapse
|
44
|
Viola F, Dyverfeldt P, Carlhäll CJ, Ebbers T. Data Quality and Optimal Background Correction Order of Respiratory-Gated k-Space Segmented Spoiled Gradient Echo (SGRE) and Echo Planar Imaging (EPI)-Based 4D Flow MRI. J Magn Reson Imaging 2019; 51:885-896. [PMID: 31332874 PMCID: PMC7027768 DOI: 10.1002/jmri.26879] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Revised: 07/10/2019] [Accepted: 07/10/2019] [Indexed: 12/23/2022] Open
Abstract
Background A reduction in scan time of 4D Flow MRI would facilitate clinical application. A recent study indicates that echo‐planar imaging (EPI) 4D Flow MRI allows for a reduction in scan time and better data quality than the recommended k‐space segmented spoiled gradient echo (SGRE) sequence. It was argued that the poor data quality of SGRE was related to the nonrecommended absence of respiratory motion compensation. However, data quality can also be affected by the background offset compensation. Purpose To compare the data quality of respiratory motion‐compensated SGRE and EPI 4D Flow MRI and their dependence on background correction (BC) order. Study Type Retrospective. Subjects Eighteen healthy subjects (eight female, mean age 32 ± 5 years). Field Strength and Sequence 1.5 T. [Correction added on July 26, 2019, after first online publication: The preceding field strength was corrected.] SGRE and EPI‐based 4D Flow MRI. Assessment Data quality was investigated visually and by comparing flows through the cardiac valves and aorta. Measurements were obtained from transvalvular flow and pathline analysis. Statistical Tests Linear regression and Bland–Altman analysis were used. Wilcoxon test was used for comparison of visual scoring. Student's t‐test was used for comparison of flow volumes. Results No significant difference was found by visual inspection (P = 0.08). Left ventricular (LV) flows were strongly and very strongly associated with SGRE and EPI, respectively (R2 = 0.86–0.94 SGRE; 0.71–0.79 EPI, BC0–4). LV and right ventricular (RV) outflows and LV pathline flows were very strongly associated (R2 = 0.93–0.95 SGRE; 0.88–0.91 EPI, R2 = 0.91–0.95 SGRE; 0.91–0.93 EPI, BC1–4). EPI LV outflow was lower than the short‐axis‐based stroke volume. EPI RV outflow and proximal descending aortic flow were lower than SGREs. Data Conclusion Both sequences yielded good internal data consistency when an adequate background correction was applied. Second and first BC order were considered sufficient for transvalvular flow analysis in SGRE and EPI, respectively. Higher BC orders were preferred for particle tracing. Level of Evidence 4 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2020;51:885–896.
Collapse
Affiliation(s)
- Federica Viola
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Petter Dyverfeldt
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
45
|
Zhong L, Schrauben EM, Garcia J, Uribe S, Grieve SM, Elbaz MSM, Barker AJ, Geiger J, Nordmeyer S, Marsden A, Carlsson M, Tan RS, Garg P, Westenberg JJM, Markl M, Ebbers T. Intracardiac 4D Flow MRI in Congenital Heart Disease: Recommendations on Behalf of the ISMRM Flow & Motion Study Group. J Magn Reson Imaging 2019; 50:677-681. [PMID: 31317587 DOI: 10.1002/jmri.26858] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 06/21/2019] [Accepted: 06/21/2019] [Indexed: 11/08/2022] Open
Abstract
LEVEL OF EVIDENCE 5 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2019;50:677-681.
Collapse
Affiliation(s)
- Liang Zhong
- National Heart Centre Singapore, Singapore; Duke-NUS Medical School Singapore, National University of Singapore, Singapore
| | - Eric M Schrauben
- Translational Medicine, Hospital for Sick Children, Toronto, Canada
| | - Julio Garcia
- Departments of Radiology and Cardiac Sciences, University of Calgary, Calgary, Canada
| | - Sergio Uribe
- Millennium Nucleus for Cardiovascular Magnetic Resonance, Radiology Department and Biomedical Imaging Center, School of Medicine, Pontifica Universidad Catolica de Chile, Chile
| | - Stuart M Grieve
- Sydney Translational Imaging Laboratory, Heart Research Institute, Charles Perkins Centre, University of Sydney, Australia; Department of Radiology, Royal Prince Alfred Hospital, Camperdown, Australia
| | - Mohammed S M Elbaz
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Alex J Barker
- Department of Radiology and Bioengineering, University of Colorado, Anschutz Medical Campus, Denver, Colorado, USA
| | - Julia Geiger
- Department of Diagnostic Imaging, University Children's Hospital Zurich, Switzerland
| | - Sarah Nordmeyer
- Department of Pediatric Cardiology and Congenital Heart Diseases German Heart Center Berlin Germany; Institute for Cardiovascular Computer-assisted Medicine, Charité - Universitätsmedizin, Berlin, Germany
| | - Alison Marsden
- Departments of Pediatrics and Bioengineering, Stanford University, Stanford, California, USA
| | | | - Ru-San Tan
- National Heart Centre Singapore, Singapore; Duke-NUS Medical School Singapore, National University of Singapore, Singapore
| | | | | | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Tino Ebbers
- Department of Medical and Health Sciences and Center for Medical Imaging Sciences and Visualization, Linköping University, Sweden
| |
Collapse
|
46
|
van Wijk WHS, Breur JMPJ, Westenberg JJM, Driessen MMP, Meijboom FJ, Driesen B, de Baat EC, Doevendans PAFM, Leiner T, Grotenhuis HB. Validation of aortic valve 4D flow analysis and myocardial deformation by cardiovascular magnetic resonance in patients after the arterial switch operation. J Cardiovasc Magn Reson 2019; 21:20. [PMID: 30879465 PMCID: PMC6421716 DOI: 10.1186/s12968-019-0527-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Accepted: 02/12/2019] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND Aortic regurgitation (AR) and subclinical left ventricular (LV) dysfunction expressed by myocardial deformation imaging are common in patients with transposition of the great arteries after the arterial switch operation (ASO). Echocardiographic evaluation is often hampered by reduced acoustic window settings. Cardiovascular magnetic resonance (CMR) imaging provides a robust alternative as it allows for comprehensive assessment of degree of AR and LV function. The purpose of this study is to validate CMR based 4-dimensional flow quantification (4D flow) for degree of AR and feature tracking strain measurements for LV deformation assessment in ASO patients. METHODS A total of 81 ASO patients (median 20.6 years, IQR 13.5-28.4) underwent CMR for 4D and 2D flow analysis. CMR global longitudinal strain (GLS) feature tracking was compared to echocardiographic (echo) speckle tracking. Agreements between and within tests were expressed as intra-class correlation coefficients (ICC). RESULTS Eleven ASO patients (13.6%) showed AR > 5% by 4D flow, with good correlation to 2D flow assessment (ICC = 0.85). 4D flow stroke volume of the aortic valve demonstrated good agreement to 2D stroke volume over the mitral valve (internal validation, ICC = 0.85) and multi-slice planimetric LV stroke volume (external validation, ICC = 0.95). 2D flow stroke volume showed slightly less, though still good agreement with 4D flow (ICC = 0.78) and planimetric LV stroke volume (ICC = 0.87). GLS by CMR was normal (- 18.8 ± 4.4%) and demonstrated good agreement with GLS and segmental analysis by echocardiographic speckle tracking (GLS = - 17.3 ± 3.1%, ICC of 0.80). CONCLUSIONS Aortic 4D flow and CMR feature tracking GLS analysis demonstrate good to excellent agreement with 2D flow assessment and echocardiographic speckle tracking, respectively, and can therefore reliably be used for an integrated and comprehensive CMR analysis of aortic valve competence and LV deformation analysis in ASO patients.
Collapse
Affiliation(s)
- W. H. S. van Wijk
- Department of Pediatric Cardiology, University Medical Center Utrecht / Wilhelmina Children’s Hospital, Utrecht, The Netherlands
| | - J. M. P. J. Breur
- Department of Pediatric Cardiology, University Medical Center Utrecht / Wilhelmina Children’s Hospital, Utrecht, The Netherlands
| | - J. J. M. Westenberg
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - M. M. P. Driessen
- Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - F. J. Meijboom
- Department of Pediatric Cardiology, University Medical Center Utrecht / Wilhelmina Children’s Hospital, Utrecht, The Netherlands
- Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - B. Driesen
- Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands
- Department of Cardiology, Radboud UMC Nijmegen, Nijmegen, The Netherlands
| | - E. C. de Baat
- Department of Pediatric Cardiology, University Medical Center Utrecht / Wilhelmina Children’s Hospital, Utrecht, The Netherlands
| | - P. A. F. M. Doevendans
- Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands
- Netherlands Hearth Institute, Utrecht, The Netherlands
- Central Military Hospital, Utrecht, The Netherlands
| | - T. Leiner
- Department of Radiology, University Medical Center Utrecht, Postal box 85090, 3508 AB Utrecht, The Netherlands
| | - H. B. Grotenhuis
- Department of Pediatric Cardiology, University Medical Center Utrecht / Wilhelmina Children’s Hospital, Utrecht, The Netherlands
| |
Collapse
|
47
|
Imaging Assessment of Tricuspid Regurgitation Severity. JACC Cardiovasc Imaging 2019; 12:469-490. [DOI: 10.1016/j.jcmg.2018.07.033] [Citation(s) in RCA: 123] [Impact Index Per Article: 24.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 07/24/2018] [Accepted: 07/25/2018] [Indexed: 01/30/2023]
|
48
|
Bock J, Töger J, Bidhult S, Markenroth Bloch K, Arvidsson P, Kanski M, Arheden H, Testud F, Greiser A, Heiberg E, Carlsson M. Validation and reproducibility of cardiovascular 4D-flow MRI from two vendors using 2 × 2 parallel imaging acceleration in pulsatile flow phantom and in vivo with and without respiratory gating. Acta Radiol 2019; 60:327-337. [PMID: 30479136 PMCID: PMC6402051 DOI: 10.1177/0284185118784981] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Background 4D-flow magnetic resonance imaging (MRI) is increasingly used. Purpose To validate 4D-flow sequences in phantom and in vivo, comparing volume flow
and kinetic energy (KE) head-to-head, with and without respiratory
gating. Material and Methods Achieva dStream (Philips Healthcare) and MAGNETOM Aera (Siemens Healthcare)
1.5-T scanners were used. Phantom validation measured pulsatile,
three-dimensional flow with 4D-flow MRI and laser particle imaging
velocimetry (PIV) as reference standard. Ten healthy participants underwent
three cardiac MRI examinations each, consisting of cine-imaging, 2D-flow
(aorta, pulmonary artery), and 2 × 2 accelerated 4D-flow with (Resp+) and
without (Resp−) respiratory gating. Examinations were acquired consecutively
on both scanners and one examination repeated within two weeks. Volume flow
in the great vessels was compared between 2D- and 4D-flow. KE were
calculated for all time phases and voxels in the left ventricle. Results Phantom results showed high accuracy and precision for both scanners.
In vivo, higher accuracy and precision (P < 0.001) was
found for volume flow for the Aera prototype with Resp+ (–3.7 ± 10.4 mL,
r = 0.89) compared to the Achieva product sequence (–17.8 ± 18.6 mL,
r = 0.56). 4D-flow Resp− on Aera had somewhat larger bias (–9.3 ± 9.6 mL,
r = 0.90) compared to Resp+ (P = 0.005). KE measurements
showed larger differences between scanners on the same day compared to the
same scanner at different days. Conclusion Sequence-specific in vivo validation of 4D-flow is needed before clinical
use. 4D-flow with the Aera prototype sequence with a clinically acceptable
acquisition time (<10 min) showed acceptable bias in healthy controls to
be considered for clinical use. Intra-individual KE comparisons should use
the same sequence.
Collapse
Affiliation(s)
- Jelena Bock
- Department of Clinical Sciences, Lund University, Clinical Physiology, Skåne University Hospital, Lund, Sweden
| | - Johannes Töger
- Department of Clinical Sciences, Lund University, Clinical Physiology, Skåne University Hospital, Lund, Sweden
- Department of Diagnostic Radiology, Lund University, Skåne University Hospital, Lund, Sweden
| | - Sebastian Bidhult
- Department of Clinical Sciences, Lund University, Clinical Physiology, Skåne University Hospital, Lund, Sweden
- Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund, Sweden
| | - Karin Markenroth Bloch
- Philips Healthcare, Lund, Sweden
- Lund University Bioimaging Center, Lund University, Lund, Sweden
| | - Per Arvidsson
- Department of Clinical Sciences, Lund University, Clinical Physiology, Skåne University Hospital, Lund, Sweden
| | - Mikael Kanski
- Department of Clinical Sciences, Lund University, Clinical Physiology, Skåne University Hospital, Lund, Sweden
| | - Håkan Arheden
- Department of Clinical Sciences, Lund University, Clinical Physiology, Skåne University Hospital, Lund, Sweden
| | | | | | - Einar Heiberg
- Department of Clinical Sciences, Lund University, Clinical Physiology, Skåne University Hospital, Lund, Sweden
- Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund, Sweden
| | - Marcus Carlsson
- Department of Clinical Sciences, Lund University, Clinical Physiology, Skåne University Hospital, Lund, Sweden
| |
Collapse
|
49
|
François CJ. Automatic Quantification of Valvular Function with Four-dimensional Flow MRI: Ready for Routine Clinical Use? Radiology 2019; 290:79-80. [DOI: 10.1148/radiol.2018182228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Christopher J. François
- From the Department of Radiology, University of Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI 53792
| |
Collapse
|
50
|
Kamphuis VP, Roest AAW, Ajmone Marsan N, van den Boogaard PJ, Kroft LJM, Aben JP, Bax JJ, de Roos A, Lamb HJ, Westenberg JJM. Automated Cardiac Valve Tracking for Flow Quantification with Four-dimensional Flow MRI. Radiology 2018; 290:70-78. [PMID: 30375924 DOI: 10.1148/radiol.2018180807] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Purpose To compare four-dimensional flow MRI with automated valve tracking to manual valve tracking in patients with acquired or congenital heart disease and healthy volunteers. Materials and Methods In this retrospective study, data were collected from 114 patients and 46 volunteers who underwent four-dimensional flow MRI at 1.5 T or 3.0 T from 2006 through 2017. Among the 114 patients, 33 had acquired and 81 had congenital heart disease (median age, 17 years; interquartile range [IQR], 13-49 years), 51 (45%) were women, and 63 (55%) were men. Among the 46 volunteers (median age, 28 years; IQR, 22-36 years), there were 19 (41%) women and 27 (59%) men. Two orthogonal cine views of each valve were used for valve tracking. Wilcoxon signed-rank test was used to compare analysis times, net forward volumes (NFVs), and regurgitant fractions. Intra- and interobserver variability was tested by using intraclass correlation coefficients (ICCs). Results Analysis time was shorter for automated versus manual tracking (all patients, 14 minutes [IQR, 12-15 minutes] vs 25 minutes [IQR, 20-25 minutes]; P < .001). Although overall differences in NFV and regurgitant fraction were comparable between both methods, NFV variation over four valves was smaller for automated versus manual tracking (all patients, 4.9% [IQR, 3.3%-6.7%] vs 9.8% [IQR, 5.1%-14.7%], respectively; P < .001). Regurgitation severity was discordant for seven pulmonary valves, 22 mitral valves, and 21 tricuspid valves. Intra- and interobserver agreement for automated tracking was excellent for NFV assessment (intra- and interobserver, ICC ≥ 0.99) and strong to excellent for regurgitant fraction assessment (intraobserver, ICC ≥ 0.94; interobserver, ICC ≥ 0.89). Conclusion Automated valve tracking reduces analysis time and improves reliability of valvular flow quantification with four-dimensional flow MRI in patients with acquired or congenital heart disease and in healthy volunteers. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by François in this issue.
Collapse
Affiliation(s)
- Vivian P Kamphuis
- From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.)
| | - Arno A W Roest
- From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.)
| | - Nina Ajmone Marsan
- From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.)
| | - Pieter J van den Boogaard
- From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.)
| | - Lucia J M Kroft
- From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.)
| | - Jean-Paul Aben
- From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.)
| | - Jeroen J Bax
- From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.)
| | - Albert de Roos
- From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.)
| | - Hildo J Lamb
- From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.)
| | - Jos J M Westenberg
- From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.)
| |
Collapse
|