1
|
Melich R, Emmel P, Vivien A, Sechaud F, Mandaroux C, Mhedhbi S, Bussat P, Tardy I, Cherkaoui S. In Vitro and In Vivo Behavioral Evaluation of Condensed Lipid-Coated Perfluorocarbon Nanodroplets. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:1010-1019. [PMID: 38637170 DOI: 10.1016/j.ultrasmedbio.2024.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 03/08/2024] [Accepted: 03/21/2024] [Indexed: 04/20/2024]
Abstract
OBJECTIVE Phase-shift contrast agents consist of a liquid perfluorocarbon core that can be vaporized by ultrasound to generate echogenic contrast with excellent spatiotemporal control. The purpose of the present work was to evaluate the in vitro and in vivo behavior of condensed lipid-shelled nanodroplets (NDs) using different analytical procedures. METHODS Perfluorobutane NDs were prepared by condensation of precursor fluorescently labeled lipid-shelled microbubbles (MBs) and were characterized in terms of size distribution, gas core content and in vitro stability in blood, as well as for their acoustic vaporization behavior using a custom-made setup. In particular, the in vivo behavior of the NDs was thoroughly investigated after intravenous bolus injection in rats. To this end, we report, for the first time, the efficient use of three complementary detection procedures to assess the in vivo persistence of NDs: (i) ultrasound contrast imaging of vaporized NDs, (ii) gas chromatography-mass spectrometry to determine the perfluorobutane core content and (iii) fluorescence intensity measurement in the collected blood samples. RESULTS The Coulter Counter Multisizer results confirmed the size distribution shift post-condensation. Furthermore, similar PFB concentrations from MB and ND suspensions were obtained, indicating an exceptionally low rate of MB breakage and spontaneous nanodroplet vaporization. As expected, these nanoscale droplets have longer circulation times compared with clinically approved MBs, and only slight variations in half-life were observed between the three monitoring procedures. Finally, echogenic signal observed in focal areas of the liver and spleen after vaporization was confirmed by accumulation of fluorescent nanodroplets in these organs. CONCLUSION These results further contribute to our understanding of both the in vitro and in vivo behavior of sono-responsive nanodroplets, which is key to enabling efficient clinical translation.
Collapse
|
2
|
Schoen S, Kilinc MS, Lee H, Guo Y, Degertekin FL, Woodworth GF, Arvanitis C. Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound. Adv Drug Deliv Rev 2022; 180:114043. [PMID: 34801617 PMCID: PMC8724442 DOI: 10.1016/j.addr.2021.114043] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 09/27/2021] [Accepted: 11/04/2021] [Indexed: 02/06/2023]
Abstract
Brain tumors are particularly challenging malignancies, due to their location in a structurally and functionally distinct part of the human body - the central nervous system (CNS). The CNS is separated and protected by a unique system of brain and blood vessel cells which together prevent most bloodborne therapeutics from entering the brain tumor microenvironment (TME). Recently, great strides have been made through microbubble (MB) ultrasound contrast agents in conjunction with ultrasound energy to locally increase the permeability of brain vessels and modulate the brain TME. As we elaborate in this review, this physical method can effectively deliver a wide range of anticancer agents, including chemotherapeutics, antibodies, and nanoparticle drug conjugates across a range of preclinical brain tumors, including high grade glioma (glioblastoma), diffuse intrinsic pontine gliomas, and brain metastasis. Moreover, recent evidence suggests that this technology can promote the effective delivery of novel immunotherapeutic agents, including immune check-point inhibitors and chimeric antigen receptor T cells, among others. With early clinical studies demonstrating safety, and several Phase I/II trials testing the preclinical findings underway, this technology is making firm steps towards shaping the future treatments of primary and metastatic brain cancer. By elaborating on its key components, including ultrasound systems and MB technology, along with methods for closed-loop spatial and temporal control of MB activity, we highlight how this technology can be tuned to enable new, personalized treatment strategies for primary brain malignancies and brain metastases.
Collapse
Affiliation(s)
- Scott Schoen
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - M. Sait Kilinc
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Hohyun Lee
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Yutong Guo
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - F. Levent Degertekin
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Graeme F. Woodworth
- Department of Neurosurgery, University of Maryland School of Medicine, Baltimore, MD 21201, USA,Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, College Park, MD 20742, USA,Fischell Department of Bioengineering A. James Clarke School of Engineering, University of Maryland
| | - Costas Arvanitis
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA,Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
| |
Collapse
|
3
|
Braun T, Sünner L, Hachenberger M, Müller C, Wietelmann A, Juenemann M, Pons-Kühnemann J, Kaps M, Gerriets T, Tschernatsch M, Roth J, Yenigün M. Microbubble-mediated sonothrombolysis with BR38 of a venous full blood thrombus in a rat embolic stroke model. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1061. [PMID: 34422973 PMCID: PMC8339866 DOI: 10.21037/atm-21-75] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 04/14/2021] [Indexed: 11/30/2022]
Abstract
Background Early recanalization of an occluded vessel is associated with a better clinical outcome in acute ischemic stroke. Intravenous thrombolysis using recombinant tissue plasminogen activator (rt-PA) is only available in a minority of patients and often fails to reopen the occluded vessel. Mechanical recanalization is more effective in this matter but only available for selected patients when a thrombectomy centre can be reached. Therefore, sonothrombolysis might represent an alternative or complementary approach. Here, we tested microbubble-mediated sonothrombolysis (mmSTL) in a thromboembolic stroke model for middle cerebral artery occlusion (MCAO) in rats. Methods Sixty-seven male Wistar rats underwent MCAO using an autologous full blood thrombus and were randomly assigned to four groups receiving rt-PA, mmSTL, a combination of both, or a placebo. Diagnostic workup included neurological examination, assessment of infarct size, and presence of intracerebral haemorrhage by magnetic resonance imaging (MRI) and presence of microbleedings in histological staining. Results Neurological examination revealed no differences between the treatment groups. In all treatment groups, there was a reduction in infarct size 24 hours after MCAO as compared to the placebo (P≤0.05), but there were no differences between the active treatment groups (P>0.05) (placebo 0.75±0.10 cm3; mmSTL 0.43±0.07 cm3; rt-PA 0.4±0.07 cm3; mmSTL + rt-PA 0.27±0.08 cm3). Histological staining displayed intracerebral microbleedings in all animals. The frequency of gross bleeding detected by MRI did not differ between the groups (placebo 3; mmSTL 4; rt-PA 2; mmSTL + rt-PA 2; P>0.05) and was not associated with worse performance in clinical testing (P>0.05). There were no statistical differences in the mortality between the groups (P>0.05). Conclusions Our study showed the efficacy and safety of mmSTL with or without rt-PA in an embolic rat stroke model using a continuous full blood thrombus. Sonothrombolysis might be useful for patients who need to be transported to a thrombectomy centre or for those with distal vessel occlusion.
Collapse
Affiliation(s)
- Tobias Braun
- Department of Neurology, Faculty of Medicine, Justus-Liebig-University, Giessen, Germany.,Heart & Brain Research Group, Justus-Liebig-University Giessen and Kerckhoff Clinic, Bad Nauheim, Germany
| | - Laura Sünner
- Heart & Brain Research Group, Justus-Liebig-University Giessen and Kerckhoff Clinic, Bad Nauheim, Germany
| | - Maaike Hachenberger
- Department of Neurology, Faculty of Medicine, Justus-Liebig-University, Giessen, Germany.,Heart & Brain Research Group, Justus-Liebig-University Giessen and Kerckhoff Clinic, Bad Nauheim, Germany
| | - Clemens Müller
- Department of Radiology, Kerckhoff Clinic, Bad Nauheim, Germany
| | - Astrid Wietelmann
- Scientific Service Group Magnetic Resonance Imaging, Max-Planck-Institute for Heart and Lung Research, Bad Nauheim, Germany
| | - Martin Juenemann
- Department of Neurology, Faculty of Medicine, Justus-Liebig-University, Giessen, Germany.,Heart & Brain Research Group, Justus-Liebig-University Giessen and Kerckhoff Clinic, Bad Nauheim, Germany
| | - Jörn Pons-Kühnemann
- Institute of Medical Informatics, Department of Medical Statistics, Justus-Liebig-University, Giessen, Germany
| | - Manfred Kaps
- Department of Neurology, Faculty of Medicine, Justus-Liebig-University, Giessen, Germany
| | - Tibo Gerriets
- Department of Neurology, Faculty of Medicine, Justus-Liebig-University, Giessen, Germany.,Heart & Brain Research Group, Justus-Liebig-University Giessen and Kerckhoff Clinic, Bad Nauheim, Germany.,Department of Neurology, Gesundheitszentrum Wetterau, Bad Nauheim, Germany
| | - Marlene Tschernatsch
- Department of Neurology, Faculty of Medicine, Justus-Liebig-University, Giessen, Germany.,Heart & Brain Research Group, Justus-Liebig-University Giessen and Kerckhoff Clinic, Bad Nauheim, Germany.,Department of Neurology, Gesundheitszentrum Wetterau, Bad Nauheim, Germany
| | - Joachim Roth
- Department of Veterinarian Physiology and Biochemistry, Justus-Liebig-University, Giessen, Germany
| | - Mesut Yenigün
- Department of Neurology, Faculty of Medicine, Justus-Liebig-University, Giessen, Germany.,Heart & Brain Research Group, Justus-Liebig-University Giessen and Kerckhoff Clinic, Bad Nauheim, Germany
| |
Collapse
|
4
|
MacRitchie N, Noonan J, Guzik TJ, Maffia P. Molecular Imaging of Cardiovascular Inflammation. Br J Pharmacol 2021; 178:4216-4245. [PMID: 34378206 DOI: 10.1111/bph.15654] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 10/22/2020] [Accepted: 11/09/2020] [Indexed: 11/30/2022] Open
Abstract
Cardiovascular diseases (CVD), including atherosclerosis, are chronic inflammatory diseases characterised by a complex and evolving tissue micro-environment. Molecular heterogeneity of inflammatory responses translates into clinical outcomes. However, current medical imaging modalities are unable to reveal the cellular and molecular events at a level of detail that would allow more accurate and timely diagnosis and treatment. This is an inherent limitation of the current imaging tools which are restricted to anatomical or functional data. Molecular imaging - the visualization and quantification of molecules in the body - is already established in the clinic in the form of Positron Emitted Tomography (PET), yet the use of PET in CVD is limited. In this visual review, we will guide you through the current state of molecular imaging research, assessing the respective strengths and weaknesses of molecular imaging modalities, including those already being used in the clinic such as PET and magnetic resonance imaging (MRI) and emerging technologies at pre-clinical stage, such as photoacoustic imaging. We discuss the basic principles of each technology and provide key examples of their application in imaging inflammation in CVD and the added value into the diagnostic decision-making process. Finally, we discuss barriers for rapid successful clinical translation of these novel diagnostic modalities.
Collapse
Affiliation(s)
- Neil MacRitchie
- Centre for Immunobiology, Institute of Infection, Immunity and Inflammation, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, United Kingdom.,Institute of Cardiovascular and Medical Sciences, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, United Kingdom
| | | | - Tomasz J Guzik
- Institute of Cardiovascular and Medical Sciences, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, United Kingdom.,Department of Internal Medicine, Jagiellonian University, Collegium Medicum, Kraków, Poland
| | - Pasquale Maffia
- Centre for Immunobiology, Institute of Infection, Immunity and Inflammation, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, United Kingdom.,Institute of Cardiovascular and Medical Sciences, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, United Kingdom.,Department of Pharmacy, University of Naples Federico II, Naples, Italy
| |
Collapse
|
5
|
Heiles B, Terwiel D, Maresca D. The Advent of Biomolecular Ultrasound Imaging. Neuroscience 2021; 474:122-133. [PMID: 33727074 DOI: 10.1016/j.neuroscience.2021.03.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 03/04/2021] [Accepted: 03/05/2021] [Indexed: 12/23/2022]
Abstract
Ultrasound imaging is one of the most widely used modalities in clinical practice, revealing human prenatal development but also arterial function in the adult brain. Ultrasound waves travel deep within soft biological tissues and provide information about the motion and mechanical properties of internal organs. A drawback of ultrasound imaging is its limited ability to detect molecular targets due to a lack of cell-type specific acoustic contrast. To date, this limitation has been addressed by targeting synthetic ultrasound contrast agents to molecular targets. This molecular ultrasound imaging approach has proved to be successful but is restricted to the vascular space. Here, we introduce the nascent field of biomolecular ultrasound imaging, a molecular imaging approach that relies on genetically encoded acoustic biomolecules to interface ultrasound waves with cellular processes. We review ultrasound imaging applications bridging wave physics and chemical engineering with potential for deep brain imaging.
Collapse
Affiliation(s)
- Baptiste Heiles
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Dion Terwiel
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - David Maresca
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
| |
Collapse
|
6
|
Abstract
Gas-filled microbubbles are currently in clinical use as blood pool contrast agents for ultrasound imaging. The goal of this review is to discuss the trends and issues related to these relatively unusual intravascular materials, which are not small molecules per se, not polymers, not even nanoparticles, but larger micrometer size structures, compressible, flexible, elastic, and deformable. The intent is to connect current research and initial studies from 2 to 3 decades ago, tied to gas exchange between the bubbles and surrounding biological medium, in the following areas of focus: (1) parameters of microbubble movement in relation to vasculature specifics; (2) gas uptake and loss from the bubbles in the vasculature; (3) adhesion of microbubbles to target receptors in the vasculature; and (4) microbubble interaction with the surrounding vessels and tissues during insonation.Microbubbles are generally safe and require orders of magnitude lower material doses than x-ray and magnetic resonance imaging contrast agents. Application of microbubbles will soon extend beyond blood pool contrast and tissue perfusion imaging. Microbubbles can probe molecular and cellular biomarkers of disease by targeted contrast ultrasound imaging. This approach is now in clinical trials, for example, with the aim to detect and delineate tumor nodes in prostate, breast, and ovarian cancer. Imaging of inflammation, ischemia-reperfusion injury, and ischemic memory is also feasible. More importantly, intravascular microbubbles can be used for local deposition of focused ultrasound energy to enhance drug and gene delivery to cells and tissues, across endothelial barrier, especially blood-brain barrier.Overall, microbubble behavior, stability and in vivo lifetime, bioeffects upon the action of ultrasound and resulting enhancement of drug and gene delivery, as well as targeted imaging are critically dependent on the events of gas exchange between the bubbles and surrounding media, as outlined in this review.
Collapse
Affiliation(s)
- Alexander L Klibanov
- From the Cardiovascular Division, Department of Medicine and Robert M. Berne Cardiovascular Research Center, University of Virginia School of Medicine; and Departments of Biomedical Engineering, and Radiology, University of Virginia, Charlottesville, VA
| |
Collapse
|
7
|
Stride E, Segers T, Lajoinie G, Cherkaoui S, Bettinger T, Versluis M, Borden M. Microbubble Agents: New Directions. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1326-1343. [PMID: 32169397 DOI: 10.1016/j.ultrasmedbio.2020.01.027] [Citation(s) in RCA: 107] [Impact Index Per Article: 21.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 01/09/2020] [Accepted: 01/26/2020] [Indexed: 05/24/2023]
Abstract
Microbubble ultrasound contrast agents have now been in use for several decades and their safety and efficacy in a wide range of diagnostic applications have been well established. Recent progress in imaging technology is facilitating exciting developments in techniques such as molecular, 3-D and super resolution imaging and new agents are now being developed to meet their specific requirements. In parallel, there have been significant advances in the therapeutic applications of microbubbles, with recent clinical trials demonstrating drug delivery across the blood-brain barrier and into solid tumours. New agents are similarly being tailored toward these applications, including nanoscale microbubble precursors offering superior circulation times and tissue penetration. The development of novel agents does, however, present several challenges, particularly regarding the regulatory framework. This article reviews the developments in agents for diagnostic, therapeutic and "theranostic" applications; novel manufacturing techniques; and the opportunities and challenges for their commercial and clinical translation.
Collapse
Affiliation(s)
- Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK.
| | - Tim Segers
- Physics of Fluids Group, Technical Medical (TechMed) Centre, MESA+ Institute for Nanotechnology, University of Twente, The Netherlands
| | - Guillaume Lajoinie
- Physics of Fluids Group, Technical Medical (TechMed) Centre, MESA+ Institute for Nanotechnology, University of Twente, The Netherlands
| | - Samir Cherkaoui
- Bracco Suisse SA - Business Unit Imaging, Global R&D, Plan-les-Ouates, Switzerland
| | - Thierry Bettinger
- Bracco Suisse SA - Business Unit Imaging, Global R&D, Plan-les-Ouates, Switzerland
| | - Michel Versluis
- Physics of Fluids Group, Technical Medical (TechMed) Centre, MESA+ Institute for Nanotechnology, University of Twente, The Netherlands
| | - Mark Borden
- Mechanical Engineering Department, University of Colorado, Boulder, CO, USA
| |
Collapse
|
8
|
Kooiman K, Roovers S, Langeveld SAG, Kleven RT, Dewitte H, O'Reilly MA, Escoffre JM, Bouakaz A, Verweij MD, Hynynen K, Lentacker I, Stride E, Holland CK. Ultrasound-Responsive Cavitation Nuclei for Therapy and Drug Delivery. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1296-1325. [PMID: 32165014 PMCID: PMC7189181 DOI: 10.1016/j.ultrasmedbio.2020.01.002] [Citation(s) in RCA: 186] [Impact Index Per Article: 37.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 12/20/2019] [Accepted: 01/07/2020] [Indexed: 05/03/2023]
Abstract
Therapeutic ultrasound strategies that harness the mechanical activity of cavitation nuclei for beneficial tissue bio-effects are actively under development. The mechanical oscillations of circulating microbubbles, the most widely investigated cavitation nuclei, which may also encapsulate or shield a therapeutic agent in the bloodstream, trigger and promote localized uptake. Oscillating microbubbles can create stresses either on nearby tissue or in surrounding fluid to enhance drug penetration and efficacy in the brain, spinal cord, vasculature, immune system, biofilm or tumors. This review summarizes recent investigations that have elucidated interactions of ultrasound and cavitation nuclei with cells, the treatment of tumors, immunotherapy, the blood-brain and blood-spinal cord barriers, sonothrombolysis, cardiovascular drug delivery and sonobactericide. In particular, an overview of salient ultrasound features, drug delivery vehicles, therapeutic transport routes and pre-clinical and clinical studies is provided. Successful implementation of ultrasound and cavitation nuclei-mediated drug delivery has the potential to change the way drugs are administered systemically, resulting in more effective therapeutics and less-invasive treatments.
Collapse
Affiliation(s)
- Klazina Kooiman
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands.
| | - Silke Roovers
- Ghent Research Group on Nanomedicines, Lab for General Biochemistry and Physical Pharmacy, Department of Pharmaceutical Sciences, Ghent University, Ghent, Belgium
| | - Simone A G Langeveld
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Robert T Kleven
- Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, OH, USA
| | - Heleen Dewitte
- Ghent Research Group on Nanomedicines, Lab for General Biochemistry and Physical Pharmacy, Department of Pharmaceutical Sciences, Ghent University, Ghent, Belgium; Laboratory for Molecular and Cellular Therapy, Medical School of the Vrije Universiteit Brussel, Jette, Belgium; Cancer Research Institute Ghent (CRIG), Ghent University Hospital, Ghent University, Ghent, Belgium
| | - Meaghan A O'Reilly
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | | | - Ayache Bouakaz
- UMR 1253, iBrain, Université de Tours, Inserm, Tours, France
| | - Martin D Verweij
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands; Laboratory of Acoustical Wavefield Imaging, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada
| | - Ine Lentacker
- Ghent Research Group on Nanomedicines, Lab for General Biochemistry and Physical Pharmacy, Department of Pharmaceutical Sciences, Ghent University, Ghent, Belgium; Cancer Research Institute Ghent (CRIG), Ghent University Hospital, Ghent University, Ghent, Belgium
| | - Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Christy K Holland
- Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, OH, USA; Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
9
|
Molecular imaging of inflammation - Current and emerging technologies for diagnosis and treatment. Pharmacol Ther 2020; 211:107550. [PMID: 32325067 DOI: 10.1016/j.pharmthera.2020.107550] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Accepted: 10/07/2019] [Indexed: 12/12/2022]
Abstract
Inflammation is a key factor in multiple diseases including primary immune-mediated inflammatory diseases e.g. rheumatoid arthritis but also, less obviously, in many other common conditions, e.g. cardiovascular disease and diabetes. Together, chronic inflammatory diseases contribute to the majority of global morbidity and mortality. However, our understanding of the underlying processes by which the immune response is activated and sustained is limited by a lack of cellular and molecular information obtained in situ. Molecular imaging is the visualization, detection and quantification of molecules in the body. The ability to reveal information on inflammatory biomarkers, pathways and cells can improve disease diagnosis, guide and monitor therapeutic intervention and identify new targets for research. The optimum molecular imaging modality will possess high sensitivity and high resolution and be capable of non-invasive quantitative imaging of multiple disease biomarkers while maintaining an acceptable safety profile. The mainstays of current clinical imaging are computed tomography (CT), magnetic resonance imaging (MRI), ultrasound (US) and nuclear imaging such as positron emission tomography (PET). However, none of these have yet progressed to routine clinical use in the molecular imaging of inflammation, therefore new approaches are required to meet this goal. This review sets out the respective merits and limitations of both established and emerging imaging modalities as clinically useful molecular imaging tools in addition to potential theranostic applications.
Collapse
|
10
|
Frinking P, Segers T, Luan Y, Tranquart F. Three Decades of Ultrasound Contrast Agents: A Review of the Past, Present and Future Improvements. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:892-908. [PMID: 31941587 DOI: 10.1016/j.ultrasmedbio.2019.12.008] [Citation(s) in RCA: 151] [Impact Index Per Article: 30.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 12/05/2019] [Accepted: 12/06/2019] [Indexed: 06/10/2023]
Abstract
Initial reports from the 1960s describing the observations of ultrasound contrast enhancement by tiny gaseous bubbles during echocardiographic examinations prompted the development of the first ultrasound contrast agent in the 1980s. Current commercial contrast agents for echography, such as Definity, Optison, Sonazoid and SonoVue, have proven to be successful in a variety of on- and off-label clinical indications. Whereas contrast-specific technology has seen dramatic progress after the introduction of the first approved agents in the 1990s, successful clinical translation of new developments has been limited during the same period, while understanding of microbubble physical, chemical and biologic behavior has improved substantially. It is expected that for a successful development of future opportunities, such as ultrasound molecular imaging and therapeutic applications using microbubbles, new creative developments in microbubble engineering and production dedicated to further optimizing microbubble performance are required, and that they cannot rely on bubble technology developed more than 3 decades ago.
Collapse
Affiliation(s)
- Peter Frinking
- Tide Microfluidics, Capitool 41, Enschede, The Netherlands.
| | - Tim Segers
- Physics of Fluids group, University of Twente, Enschede, The Netherlands
| | - Ying Luan
- R&D Pharmaceutical Diagnostics, General Electric Healthcare, Amersham, UK
| | - François Tranquart
- R&D Pharmaceutical Diagnostics, General Electric Healthcare, Amersham, UK
| |
Collapse
|
11
|
Lattwein KR, Shekhar H, Kouijzer JJP, van Wamel WJB, Holland CK, Kooiman K. Sonobactericide: An Emerging Treatment Strategy for Bacterial Infections. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:193-215. [PMID: 31699550 PMCID: PMC9278652 DOI: 10.1016/j.ultrasmedbio.2019.09.011] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 09/03/2019] [Accepted: 09/16/2019] [Indexed: 05/04/2023]
Abstract
Ultrasound has been developed as both a diagnostic tool and a potent promoter of beneficial bio-effects for the treatment of chronic bacterial infections. Bacterial infections, especially those involving biofilm on implants, indwelling catheters and heart valves, affect millions of people each year, and many deaths occur as a consequence. Exposure of microbubbles or droplets to ultrasound can directly affect bacteria and enhance the efficacy of antibiotics or other therapeutics, which we have termed sonobactericide. This review summarizes investigations that have provided evidence for ultrasound-activated microbubble or droplet treatment of bacteria and biofilm. In particular, we review the types of bacteria and therapeutics used for treatment and the in vitro and pre-clinical experimental setups employed in sonobactericide research. Mechanisms for ultrasound enhancement of sonobactericide, with a special emphasis on acoustic cavitation and radiation force, are reviewed, and the potential for clinical translation is discussed.
Collapse
Affiliation(s)
- Kirby R Lattwein
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
| | - Himanshu Shekhar
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Joop J P Kouijzer
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Willem J B van Wamel
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Christy K Holland
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Klazina Kooiman
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| |
Collapse
|
12
|
Kanoulas E, Butler M, Rowley C, Voulgaridou V, Diamantis K, Duncan WC, McNeilly A, Averkiou M, Wijkstra H, Mischi M, Wilson RS, Lu W, Sboros V. Super-Resolution Contrast-Enhanced Ultrasound Methodology for the Identification of In Vivo Vascular Dynamics in 2D. Invest Radiol 2019; 54:500-516. [PMID: 31058661 PMCID: PMC6661242 DOI: 10.1097/rli.0000000000000565] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 02/20/2019] [Accepted: 02/20/2019] [Indexed: 12/11/2022]
Abstract
OBJECTIVES The aim of this study was to provide an ultrasound-based super-resolution methodology that can be implemented using clinical 2-dimensional ultrasound equipment and standard contrast-enhanced ultrasound modes. In addition, the aim is to achieve this for true-to-life patient imaging conditions, including realistic examination times of a few minutes and adequate image penetration depths that can be used to scan entire organs without sacrificing current super-resolution ultrasound imaging performance. METHODS Standard contrast-enhanced ultrasound was used along with bolus or infusion injections of SonoVue (Bracco, Geneva, Switzerland) microbubble (MB) suspensions. An image analysis methodology, translated from light microscopy algorithms, was developed for use with ultrasound contrast imaging video data. New features that are tailored for ultrasound contrast image data were developed for MB detection and segmentation, so that the algorithm can deal with single and overlapping MBs. The method was tested initially on synthetic data, then with a simple microvessel phantom, and then with in vivo ultrasound contrast video loops from sheep ovaries. Tracks detailing the vascular structure and corresponding velocity map of the sheep ovary were reconstructed. Images acquired from light microscopy, optical projection tomography, and optical coherence tomography were compared with the vasculature network that was revealed in the ultrasound contrast data. The final method was applied to clinical prostate data as a proof of principle. RESULTS Features of the ovary identified in optical modalities mentioned previously were also identified in the ultrasound super-resolution density maps. Follicular areas, follicle wall, vessel diameter, and tissue dimensions were very similar. An approximately 8.5-fold resolution gain was demonstrated in vessel width, as vessels of width down to 60 μm were detected and verified (λ = 514 μm). Best agreement was found between ultrasound measurements and optical coherence tomography with 10% difference in the measured vessel widths, whereas ex vivo microscopy measurements were significantly lower by 43% on average. The results were mostly achieved using video loops of under 2-minute duration that included respiratory motion. A feasibility study on a human prostate showed good agreement between density and velocity ultrasound maps with the histological evaluation of the location of a tumor. CONCLUSIONS The feasibility of a 2-dimensional contrast-enhanced ultrasound-based super-resolution method was demonstrated using in vitro, synthetic and in vivo animal data. The method reduces the examination times to a few minutes using state-of-the-art ultrasound equipment and can provide super-resolution maps for an entire prostate with similar resolution to that achieved in other studies.
Collapse
Affiliation(s)
- Evangelos Kanoulas
- From the Institute of Biochemistry, Biological Physics, and Bio Engineering, and
| | - Mairead Butler
- From the Institute of Biochemistry, Biological Physics, and Bio Engineering, and
| | - Caitlin Rowley
- Department of Physics, Heriot-Watt University, Riccarton
| | - Vasiliki Voulgaridou
- From the Institute of Biochemistry, Biological Physics, and Bio Engineering, and
| | | | - William Colin Duncan
- Center for Reproductive Health, University of Edinburgh, Edinburgh, United Kingdom
| | - Alan McNeilly
- Center for Reproductive Health, University of Edinburgh, Edinburgh, United Kingdom
| | | | | | - Massimo Mischi
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; and
| | - Rhodri Simon Wilson
- **Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, United Kingdom
| | - Weiping Lu
- From the Institute of Biochemistry, Biological Physics, and Bio Engineering, and
| | - Vassilis Sboros
- From the Institute of Biochemistry, Biological Physics, and Bio Engineering, and
| |
Collapse
|
13
|
Bressand D, Novell A, Girault A, Raoul W, Fromont-Hankard G, Escoffre JM, Lecomte T, Bouakaz A. Enhancing Nab-Paclitaxel Delivery Using Microbubble-Assisted Ultrasound in a Pancreatic Cancer Model. Mol Pharm 2019; 16:3814-3822. [DOI: 10.1021/acs.molpharmaceut.9b00416] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Diane Bressand
- UMR 1253, iBrain, Université de Tours, Inserm, 10 boulevard Tonnellé, 37032 Tours, France
- Department of Hepato-Gastroenterology and Digestive Cancerology, Université de Tours, EA7501 GICC, Team PATCH, CHRU de Tours, 10 boulevard Tonnellé, 37032 Tours, France
| | - Anthony Novell
- UMR 1253, iBrain, Université de Tours, Inserm, 10 boulevard Tonnellé, 37032 Tours, France
| | - Alban Girault
- Department of Hepato-Gastroenterology and Digestive Cancerology, Université de Tours, EA7501 GICC, Team PATCH, CHRU de Tours, 10 boulevard Tonnellé, 37032 Tours, France
| | - William Raoul
- Department of Hepato-Gastroenterology and Digestive Cancerology, Université de Tours, EA7501 GICC, Team PATCH, CHRU de Tours, 10 boulevard Tonnellé, 37032 Tours, France
| | - Gaëlle Fromont-Hankard
- Department of Pathological Anatomy and Cytology, Université de Tours, Inserm, UMR 1069, Nutrition, Croissance, Cancer, CHRU de Tours, 37032 Tours, France
| | - Jean-Michel Escoffre
- UMR 1253, iBrain, Université de Tours, Inserm, 10 boulevard Tonnellé, 37032 Tours, France
| | - Thierry Lecomte
- Department of Hepato-Gastroenterology and Digestive Cancerology, Université de Tours, EA7501 GICC, Team PATCH, CHRU de Tours, 10 boulevard Tonnellé, 37032 Tours, France
| | - Ayache Bouakaz
- UMR 1253, iBrain, Université de Tours, Inserm, 10 boulevard Tonnellé, 37032 Tours, France
| |
Collapse
|
14
|
Shekhar H, Kleven RT, Peng T, Palaniappan A, Karani KB, Huang S, McPherson DD, Holland CK. In vitro characterization of sonothrombolysis and echocontrast agents to treat ischemic stroke. Sci Rep 2019; 9:9902. [PMID: 31289285 PMCID: PMC6616381 DOI: 10.1038/s41598-019-46112-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 06/12/2019] [Indexed: 12/30/2022] Open
Abstract
The development of adjuvant techniques to improve thrombolytic efficacy is important for advancing ischemic stroke therapy. We characterized octafluoropropane and recombinant tissue plasminogen activator (rt-PA)-loaded echogenic liposomes (OFP t-ELIP) using differential interference and fluorescence microscopy, attenuation spectroscopy, and electrozone sensing. The loading of rt-PA in OFP t-ELIP was assessed using spectrophotometry. Further, it was tested whether the agent shields rt-PA against degradation by plasminogen activator inhibitor-1 (PAI-1). An in vitro system was used to assess whether ultrasound (US) combined with either Definity or OFP t-ELIP enhances rt-PA thrombolysis. Human whole blood clots were mounted in a flow system and visualized using an inverted microscope. The perfusate consisted of either (1) plasma alone, (2) rt-PA, (3) OFP t-ELIP, (4) rt-PA and US, (5) OFP t-ELIP and US, (6) Definity and US, or (7) rt-PA, Definity, and US (n = 16 clots per group). An intermittent US insonation scheme was employed (220 kHz frequency, and 0.44 MPa peak-to-peak pressures) for 30 min. Microscopic imaging revealed that OFP t-ELIP included a variety of structures such as liposomes (with and without gas) and lipid-shelled microbubbles. OFP t-ELIP preserved up to 76% of rt-PA activity in the presence of PAI-1, whereas only 24% activity was preserved for unencapsulated rt-PA. The use of US with rt-PA and Definity enhanced lytic efficacy (p < 0.05) relative to rt-PA alone. US combined with OFP t-ELIP enhanced lysis over OFP t-ELIP alone (p < 0.01). These results demonstrate that ultrasound combined with Definity or OFP t-ELIP can enhance the lytic activity relative to rt-PA or OFP t-ELIP alone, respectively.
Collapse
Affiliation(s)
- Himanshu Shekhar
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA.
| | - Robert T Kleven
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Tao Peng
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center-Houston, Houston, TX, USA
| | - Arunkumar Palaniappan
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA
| | - Kunal B Karani
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA
| | - Shaoling Huang
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center-Houston, Houston, TX, USA
| | - David D McPherson
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center-Houston, Houston, TX, USA
| | - Christy K Holland
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA.,Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
15
|
Çavuşoğlu M, Zhang J, Ielacqua GD, Pellegrini G, Signorell RD, Papachristodoulou A, Brambilla D, Roth P, Weller M, Rudin M, Martin E, Leroux JC, Werner B. Closed-loop cavitation control for focused ultrasound-mediated blood-brain barrier opening by long-circulating microbubbles. Phys Med Biol 2019; 64:045012. [PMID: 30577029 DOI: 10.1088/1361-6560/aafaa5] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Focused ultrasound (FUS) exposure in the presence of microbubbles (MBs) has been successfully used in the delivery of various sizes of therapeutic molecules across the blood-brain barrier (BBB). While acoustic pressure is correlated with the BBB opening size, real-time control of BBB opening to avoid vascular and neural damage is still a challenge. This arises mainly from the variability of FUS-MB interactions due to the variations of animal-specific metabolic environment and specific experimental setup. In this study, we demonstrate a closed-loop cavitation control framework to induce BBB opening for delivering large therapeutic molecules without causing macro tissue damages. To this end, we performed in mice long-term (5 min) cavitation monitoring facilitated by using long-circulating MBs. Monitoring the long-term temporal kinetics of the MBs under varying level of FUS pressure allowed to identify in situ, animal specific activity regimes forming pressure-dependent activity bands. This enables to determine the boundaries of each activity band (i.e. steady oscillation, transition, inertial cavitation) independent from the physical and physiological dynamics of the experiment. However, such a calibration approach is time consuming and to speed up characterization of the in situ, animal specific FUS-MB dynamics, we tested a novel method called 'pre-calibration' that closely reproduces the results of long-term monitoring but with a much shorter duration. Once the activity bands are determined from the pre-calibration method, an operation band can be selected around the desired cavitation dose. To drive cavitation in the selected operation band, we developed an adaptive, closed-loop controller that updates the acoustic pressure between each sonication based on measured cavitation dose. Finally, we quantitatively assessed the safety of different activity bands and validated the proposed methods and controller framework. The proposed framework serves to optimize the FUS pressure instantly to maintain the targeted cavitation level while improving safety control.
Collapse
Affiliation(s)
- Mustafa Çavuşoğlu
- Center for MR-Research, University Children's Hospital Zurich, 8032 Zurich, Switzerland. Institute for Biomedical Engineering, ETH Zurich, 8091 Zurich, Switzerland. Information Technology and Electrical Engineering Department, Swiss Federal Institute of Technology, Institute for Biomedical Engineering, ETH Zurich, ETZ F 64.1, Gloriastrasse 35, 8092, Zurich, Switzerland. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Ultrasound-Targeted Microbubble Destruction (UTMD) for Localized Drug Delivery into Tumor Tissue. Ing Rech Biomed 2019. [DOI: 10.1016/j.irbm.2018.11.005] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
17
|
Chemotherapy sensitization of glioblastoma by focused ultrasound-mediated delivery of therapeutic liposomes. J Control Release 2018; 295:130-139. [PMID: 30537486 DOI: 10.1016/j.jconrel.2018.12.009] [Citation(s) in RCA: 72] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 12/04/2018] [Accepted: 12/07/2018] [Indexed: 02/08/2023]
Abstract
In glioblastoma, the benefit from temozolomide chemotherapy is largely limited to a subgroup of patients (30-35%) with tumors exhibiting methylation of the promoter region of the O6-methylguanine-DNA methyltransferase (MGMT) gene. In order to allow more patients to benefit from this treatment, we explored magnetic resonance image-guided microbubble-enhanced low-intensity pulsed focused ultrasound (LIFU) to transiently open the blood-brain barrier and deliver a first-in-class liposome-loaded small molecule MGMT inactivator in mice bearing temozolomide-resistant gliomas. We demonstrate that a liposomal O6-(4-bromothenyl)guanine (O6BTG) derivative can efficiently target MGMT, thereby sensitizing murine and human glioma cells to temozolomide in vitro. Furthermore, we report that image-guided LIFU mediates the delivery of the stable liposomal MGMT inactivator in the tumor region resulting in potent MGMT depletion in vivo. Treatment with this new liposomal MGMT inactivator facilitated by LIFU-mediated blood-brain barrier opening reduced tumor growth and significantly prolonged survival of glioma-bearing mice, when combined with temozolomide chemotherapy. Exploring this novel combined approach in the clinic to treat glioblastoma patients with MGMT promoter-unmethylated tumors is warranted.
Collapse
|
18
|
Wang S, Hossack JA, Klibanov AL. Targeting of microbubbles: contrast agents for ultrasound molecular imaging. J Drug Target 2018; 26:420-434. [PMID: 29258335 DOI: 10.1080/1061186x.2017.1419362] [Citation(s) in RCA: 71] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
For contrast ultrasound imaging, the most efficient contrast agents comprise highly compressible gas-filled microbubbles. These micrometer-sized particles are typically filled with low-solubility perfluorocarbon gases, and coated with a thin shell, often a lipid monolayer. These particles circulate in the bloodstream for several minutes; they demonstrate good safety and are already in widespread clinical use as blood pool agents with very low dosage necessary (sub-mg per injection). As ultrasound is an ubiquitous medical imaging modality, with tens of millions of exams conducted annually, its use for molecular/targeted imaging of biomarkers of disease may enable wider implementation of personalised medicine applications, precision medicine, non-invasive quantification of biomarkers, targeted guidance of biopsy and therapy in real time. To achieve this capability, microbubbles are decorated with targeting ligands, possessing specific affinity towards vascular biomarkers of disease, such as tumour neovasculature or areas of inflammation, ischaemia-reperfusion injury or ischaemic memory. Once bound to the target, microbubbles can be selectively visualised to delineate disease location by ultrasound imaging. This review discusses the general design trends and approaches for such molecular ultrasound imaging agents, which are currently at the advanced stages of development, and are evolving towards widespread clinical trials.
Collapse
Affiliation(s)
- Shiying Wang
- a Department of Biomedical Engineering , University of Virginia , Charlottesville , VA , USA
| | - John A Hossack
- a Department of Biomedical Engineering , University of Virginia , Charlottesville , VA , USA
| | - Alexander L Klibanov
- a Department of Biomedical Engineering , University of Virginia , Charlottesville , VA , USA.,b Cardiovascular Division (Department of Medicine), Robert M Berne Cardiovascular Research Center , University of Virginia , Charlottesville , VA , USA
| |
Collapse
|
19
|
Willmann JK, Bonomo L, Testa AC, Rinaldi P, Rindi G, Valluru KS, Petrone G, Martini M, Lutz AM, Gambhir SS. Ultrasound Molecular Imaging With BR55 in Patients With Breast and Ovarian Lesions: First-in-Human Results. J Clin Oncol 2017; 35:2133-2140. [PMID: 28291391 DOI: 10.1200/jco.2016.70.8594] [Citation(s) in RCA: 154] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Purpose We performed a first-in-human clinical trial on ultrasound molecular imaging (USMI) in patients with breast and ovarian lesions using a clinical-grade contrast agent (kinase insert domain receptor [KDR] -targeted contrast microbubble [MBKDR]) that is targeted at the KDR, one of the key regulators of neoangiogenesis in cancer. The aim of this study was to assess whether USMI using MBKDR is safe and allows assessment of KDR expression using immunohistochemistry (IHC) as the gold standard. Methods Twenty-four women (age 48 to 79 years) with focal ovarian lesions and 21 women (age 34 to 66 years) with focal breast lesions were injected intravenously with MBKDR (0.03 to 0.08 mL/kg of body weight), and USMI of the lesions was performed starting 5 minutes after injection up to 29 minutes. Blood pressure, ECG, oxygen levels, heart rate, CBC, and metabolic panel were obtained before and after MBKDR administration. Persistent focal MBKDR binding on USMI was assessed. Patients underwent surgical resection of the target lesions, and tissues were stained for CD31 and KDR by IHC. Results USMI with MBKDR was well tolerated by all patients without safety concerns. Among the 40 patients included in the analysis, KDR expression on IHC matched well with imaging signal on USMI in 93% of breast and 85% of ovarian malignant lesions. Strong KDR-targeted USMI signal was present in 77% of malignant ovarian lesions, with no targeted signal seen in 78% of benign ovarian lesions. Similarly, strong targeted signal was seen in 93% of malignant breast lesions with no targeted signal present in 67% of benign breast lesions. Conclusion USMI with MBKDR is clinically feasible and safe, and KDR-targeted USMI signal matches well with KDR expression on IHC. This study lays the foundation for a new field of clinical USMI in cancer.
Collapse
Affiliation(s)
- Jürgen K Willmann
- Jürgen K. Willmann, Keerthi S. Valluru, Amelie M. Lutz, and Sanjiv S. Gambhir, Stanford University, Stanford, CA; and Lorenzo Bonomo, Antonia Carla Testa, Pierluigi Rinaldi, Guido Rindi, Gianluigi Petrone, and Maurizio Martini, Universitary Policlinic A. Gemelli-Foundation, Catholic University, Rome, Italy
| | - Lorenzo Bonomo
- Jürgen K. Willmann, Keerthi S. Valluru, Amelie M. Lutz, and Sanjiv S. Gambhir, Stanford University, Stanford, CA; and Lorenzo Bonomo, Antonia Carla Testa, Pierluigi Rinaldi, Guido Rindi, Gianluigi Petrone, and Maurizio Martini, Universitary Policlinic A. Gemelli-Foundation, Catholic University, Rome, Italy
| | - Antonia Carla Testa
- Jürgen K. Willmann, Keerthi S. Valluru, Amelie M. Lutz, and Sanjiv S. Gambhir, Stanford University, Stanford, CA; and Lorenzo Bonomo, Antonia Carla Testa, Pierluigi Rinaldi, Guido Rindi, Gianluigi Petrone, and Maurizio Martini, Universitary Policlinic A. Gemelli-Foundation, Catholic University, Rome, Italy
| | - Pierluigi Rinaldi
- Jürgen K. Willmann, Keerthi S. Valluru, Amelie M. Lutz, and Sanjiv S. Gambhir, Stanford University, Stanford, CA; and Lorenzo Bonomo, Antonia Carla Testa, Pierluigi Rinaldi, Guido Rindi, Gianluigi Petrone, and Maurizio Martini, Universitary Policlinic A. Gemelli-Foundation, Catholic University, Rome, Italy
| | - Guido Rindi
- Jürgen K. Willmann, Keerthi S. Valluru, Amelie M. Lutz, and Sanjiv S. Gambhir, Stanford University, Stanford, CA; and Lorenzo Bonomo, Antonia Carla Testa, Pierluigi Rinaldi, Guido Rindi, Gianluigi Petrone, and Maurizio Martini, Universitary Policlinic A. Gemelli-Foundation, Catholic University, Rome, Italy
| | - Keerthi S Valluru
- Jürgen K. Willmann, Keerthi S. Valluru, Amelie M. Lutz, and Sanjiv S. Gambhir, Stanford University, Stanford, CA; and Lorenzo Bonomo, Antonia Carla Testa, Pierluigi Rinaldi, Guido Rindi, Gianluigi Petrone, and Maurizio Martini, Universitary Policlinic A. Gemelli-Foundation, Catholic University, Rome, Italy
| | - Gianluigi Petrone
- Jürgen K. Willmann, Keerthi S. Valluru, Amelie M. Lutz, and Sanjiv S. Gambhir, Stanford University, Stanford, CA; and Lorenzo Bonomo, Antonia Carla Testa, Pierluigi Rinaldi, Guido Rindi, Gianluigi Petrone, and Maurizio Martini, Universitary Policlinic A. Gemelli-Foundation, Catholic University, Rome, Italy
| | - Maurizio Martini
- Jürgen K. Willmann, Keerthi S. Valluru, Amelie M. Lutz, and Sanjiv S. Gambhir, Stanford University, Stanford, CA; and Lorenzo Bonomo, Antonia Carla Testa, Pierluigi Rinaldi, Guido Rindi, Gianluigi Petrone, and Maurizio Martini, Universitary Policlinic A. Gemelli-Foundation, Catholic University, Rome, Italy
| | - Amelie M Lutz
- Jürgen K. Willmann, Keerthi S. Valluru, Amelie M. Lutz, and Sanjiv S. Gambhir, Stanford University, Stanford, CA; and Lorenzo Bonomo, Antonia Carla Testa, Pierluigi Rinaldi, Guido Rindi, Gianluigi Petrone, and Maurizio Martini, Universitary Policlinic A. Gemelli-Foundation, Catholic University, Rome, Italy
| | - Sanjiv S Gambhir
- Jürgen K. Willmann, Keerthi S. Valluru, Amelie M. Lutz, and Sanjiv S. Gambhir, Stanford University, Stanford, CA; and Lorenzo Bonomo, Antonia Carla Testa, Pierluigi Rinaldi, Guido Rindi, Gianluigi Petrone, and Maurizio Martini, Universitary Policlinic A. Gemelli-Foundation, Catholic University, Rome, Italy
| |
Collapse
|
20
|
Schleicher N, Tomkins AJ, Kampschulte M, Hyvelin JM, Botteron C, Juenemann M, Yeniguen M, Krombach GA, Kaps M, Spratt NJ, Gerriets T, Nedelmann M. Sonothrombolysis with BR38 Microbubbles Improves Microvascular Patency in a Rat Model of Stroke. PLoS One 2016; 11:e0152898. [PMID: 27077372 PMCID: PMC4831751 DOI: 10.1371/journal.pone.0152898] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Accepted: 03/21/2016] [Indexed: 11/19/2022] Open
Abstract
Background Early recanalization of large cerebral vessels in ischemic stroke is associated with improved clinical outcome, however persisting hypoperfusion leads to poor clinical recovery despite large vessel recanalization. Limited experimental sonothrombolysis studies have shown that addition of microbubbles during treatment can improve microvascular patency. We aimed to determine the effect of two different microbubble formulations on microvascular patency in a rat stroke model. Methods We tested BR38 and SonoVue® microbubble-enhanced sonothrombolysis in Wistar rats submitted to 90-minute filament occlusion of the middle cerebral artery. Rats were randomized to treatment (n = 6/group): control, rt-PA, or rt-PA+3-MHz ultrasound insonation with BR38 or SonoVue® at full or 1/3 dose. Treatment duration was 60 minutes, beginning after withdrawal of the filament, and sacrifice was immediately after treatment. Vascular volumes were evaluated with microcomputed tomography. Results Total vascular volume of the ipsilateral hemisphere was reduced in control and rt-PA groups (p<0.05), but was not significantly different from the contralateral hemisphere in all microbubble-treated groups (p>0.1). Conclusions Microbubble-enhanced sonothrombolysis improves microvascular patency. This effect is not dose- or microbubble formulation-dependent suggesting a class effect of microbubbles promoting microvascular reopening. This study demonstrates that microbubble-enhanced sonothrombolysis may be a therapeutic strategy for patients with persistent hypoperfusion of the ischemic territory.
Collapse
Affiliation(s)
- Nadine Schleicher
- Heart and Brain Research Group, Justus-Liebig-University, Giessen, Germany
- Department of Neurology, Justus-Liebig-University, Giessen, Germany
- Department of Cardiac Surgery, Kerckhoff Clinic, Bad Nauheim, Germany
| | - Amelia J. Tomkins
- Heart and Brain Research Group, Justus-Liebig-University, Giessen, Germany
- School of Biomedical Sciences & Pharmacy, University of Newcastle, and Hunter Medical Research Institute, Newcastle, NSW, Australia
| | - Marian Kampschulte
- Department of Diagnostic and Interventional Radiology, Justus-Liebig-University, Giessen, Germany
| | | | | | - Martin Juenemann
- Heart and Brain Research Group, Justus-Liebig-University, Giessen, Germany
- Department of Neurology, Justus-Liebig-University, Giessen, Germany
| | - Mesut Yeniguen
- Heart and Brain Research Group, Justus-Liebig-University, Giessen, Germany
- Department of Neurology, Justus-Liebig-University, Giessen, Germany
| | - Gabriele A. Krombach
- Department of Diagnostic and Interventional Radiology, Justus-Liebig-University, Giessen, Germany
| | - Manfred Kaps
- Department of Neurology, Justus-Liebig-University, Giessen, Germany
| | - Neil J. Spratt
- School of Biomedical Sciences & Pharmacy, University of Newcastle, and Hunter Medical Research Institute, Newcastle, NSW, Australia
- Hunter New England Local Health District, New Lambton, NSW, Australia
| | - Tibo Gerriets
- Heart and Brain Research Group, Justus-Liebig-University, Giessen, Germany
- Department of Neurology, Justus-Liebig-University, Giessen, Germany
- Department of Neurology, Buergerhospital Friedberg, Friedberg, Germany
| | - Max Nedelmann
- Sana Regio Klinkum, Pinneberg, Germany
- Department of Neurology, University Hospital Center Hamburg-Eppendorf, Hamburg, Germany
- * E-mail:
| |
Collapse
|
21
|
Baetke SC, Rix A, Tranquart F, Schneider R, Lammers T, Kiessling F, Lederle W. Squamous Cell Carcinoma Xenografts: Use of VEGFR2-targeted Microbubbles for Combined Functional and Molecular US to Monitor Antiangiogenic Therapy Effects. Radiology 2015; 278:430-40. [PMID: 26313618 DOI: 10.1148/radiol.2015142899] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
PURPOSE To assess the ability of vascular endothelial growth factor receptor type 2 (VEGFR2)-targeted and nontargeted ultrasonography (US) to depict antiangiogenic therapy effects and to investigate whether first-pass kinetics obtained with VEGFR2-targeted microbubbles provide independent data about tumor vascularization. MATERIALS AND METHODS Governmental approval was obtained for animal experiments. Vascularization in response to anti-vascular endothelial growth factor receptor or vehicle-control treatment (10 per group) in HaCaT-ras A-5RT3 xenografts was longitudinally assessed in mice by means of first-pass kinetics of nontargeted microbubbles (BR1, BR38; Bracco, Geneva, Switzerland) and VEGFR2-targeted microbubbles (BR55, Bracco) before and 4, 7, and 14 days after therapy. VEGFR2 expression was determined 8 minutes after BR55 injection with destruction-replenishment analysis. US data were validated with immunohistochemistry. Significant differences were evaluated with the Mann-Whitney test. RESULTS First-pass analysis with BR1, BR38, and BR55 showed similar tendencies toward decreasing vascularization, with a stronger decrease in tumors treated with anti-VEGF antibody. The median signal intensity (in arbitrary units [au]) of anti-VEGF antibody-treated versus control tumors at day 14 was as follows: BR1, 5.2 au (interquartile range [IQR], 3.2 au) vs 11.3 au (IQR, 10.0 au), respectively; BR38, 6.2 au (IQR, 3.5) vs 10.0 au (IQR, 7.8); and BR55, 9.5 au (IQR, 6.0 au) vs 13.8 au (IQR, 9.8) (P = .0230). VEGFR2 assessment with BR55 demonstrated significant differences between both groups throughout the therapy period (median signal intensity of anti-VEGF antibody-treated vs control tumors: 0.04 au [IQR, 0.1 au] vs 0.14 au [IQR, 0.08 au], respectively, at day 4, P = .0058; 0.04 au [IQR, 0.06 au] vs 0.13 au [IQR, 0.09 au] at day 7, P = .0058; and 0.06 au [IQR, 0.11 au] vs 0.16 au [IQR, 0.15 au] at day 14, P = .0247). Immunohistochemistry confirmed the lower microvessel density and VEGFR2-positive area fraction in tumors treated with anti-VEGF antibody. CONCLUSION Antiangiogenic therapy effects were detected earlier and more distinctly with VEGFR2-targeted US than with functional US. First-pass analyses with BR55, BR38, and BR1 revealed similar results, with a decrease in vascularization during therapy. Functional data showed that BR55 is not strongly affected by early binding of the microbubbles to VEGFR2. Thus, functional and molecular imaging of angiogenesis can be performed with BR55 within one examination.
Collapse
Affiliation(s)
- Sarah C Baetke
- From the Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany (S.C.B., A.R., T.L., F.K., W.L.); Bracco Suisse SA, Geneva, Switzerland (F.T.); and Merck Serono, Darmstadt, Germany (R.S.)
| | - Anne Rix
- From the Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany (S.C.B., A.R., T.L., F.K., W.L.); Bracco Suisse SA, Geneva, Switzerland (F.T.); and Merck Serono, Darmstadt, Germany (R.S.)
| | - François Tranquart
- From the Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany (S.C.B., A.R., T.L., F.K., W.L.); Bracco Suisse SA, Geneva, Switzerland (F.T.); and Merck Serono, Darmstadt, Germany (R.S.)
| | - Richard Schneider
- From the Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany (S.C.B., A.R., T.L., F.K., W.L.); Bracco Suisse SA, Geneva, Switzerland (F.T.); and Merck Serono, Darmstadt, Germany (R.S.)
| | - Twan Lammers
- From the Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany (S.C.B., A.R., T.L., F.K., W.L.); Bracco Suisse SA, Geneva, Switzerland (F.T.); and Merck Serono, Darmstadt, Germany (R.S.)
| | - Fabian Kiessling
- From the Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany (S.C.B., A.R., T.L., F.K., W.L.); Bracco Suisse SA, Geneva, Switzerland (F.T.); and Merck Serono, Darmstadt, Germany (R.S.)
| | - Wiltrud Lederle
- From the Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany (S.C.B., A.R., T.L., F.K., W.L.); Bracco Suisse SA, Geneva, Switzerland (F.T.); and Merck Serono, Darmstadt, Germany (R.S.)
| |
Collapse
|
22
|
Petit B, Bohren Y, Gaud E, Bussat P, Arditi M, Yan F, Tranquart F, Allémann E. Sonothrombolysis: the contribution of stable and inertial cavitation to clot lysis. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1402-1410. [PMID: 25601463 DOI: 10.1016/j.ultrasmedbio.2014.12.007] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Revised: 12/04/2014] [Accepted: 12/10/2014] [Indexed: 06/04/2023]
Abstract
Microbubble-mediated sonothrombolysis (STL) is a remarkable approach to vascular occlusion therapy. However, STL remains a complex process with multiple interactions between clot, ultrasound (US), microbubbles (MB) and thrombolytic drug. The aim of this study was to evaluate the ability of combining US and MB to degrade fibrin and, more specifically, to assess the roles of both stable (SC) and inertial (IC) cavitation. Human blood clots containing radiolabeled fibrin were exposed to different combinations of recombinant tissue plasminogen activator (rtPA), US (1 MHz) and phospholipid MB. Three acoustic pressures were tested: 200, 350 and 1,300 kPa (peak-negative pressure). Clot lysis was assessed by diameter loss and release of radioactive fibrin degradation products. The combination rtPA + US + MB clearly revealed that IC (1,300 kPa) was able to enhance fibrin degradation significantly (66.3 ± 1.8%) compared with rtPA alone (51.7 ± 2.0%, p < 0.001). However, SC failed to enhance fibrin degradation at an acoustic pressure of 200 kPa. At 350 kPa, a synergistic effect between rtPA and US + MB was observed with an absolute increase of 6% compared to rtPA alone (p < 0.001). Conversely, without rtPA, the combination of US + MB was unable to degrade the fibrin network (0.3 ± 0.1%, p > 0.05 vs. control), but induced a distinct loss of red blood cells throughout the entire thickness of the clot, implying that MB were able to penetrate and cavitate inside the clot.
Collapse
Affiliation(s)
- B Petit
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva, Switzerland
| | - Y Bohren
- Bracco Suisse S.A., Plan-les-Ouates, Geneva, Switzerland
| | - E Gaud
- Bracco Suisse S.A., Plan-les-Ouates, Geneva, Switzerland
| | - P Bussat
- Bracco Suisse S.A., Plan-les-Ouates, Geneva, Switzerland
| | - M Arditi
- Bracco Suisse S.A., Plan-les-Ouates, Geneva, Switzerland
| | - F Yan
- Bracco Suisse S.A., Plan-les-Ouates, Geneva, Switzerland
| | - F Tranquart
- Bracco Suisse S.A., Plan-les-Ouates, Geneva, Switzerland
| | - E Allémann
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva, Switzerland.
| |
Collapse
|
23
|
Ultrasound-guided delivery of microRNA loaded nanoparticles into cancer. J Control Release 2015; 203:99-108. [PMID: 25687306 DOI: 10.1016/j.jconrel.2015.02.018] [Citation(s) in RCA: 114] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2014] [Revised: 02/04/2015] [Accepted: 02/13/2015] [Indexed: 11/20/2022]
Abstract
Ultrasound induced microbubble cavitation can cause enhanced permeability across natural barriers of tumors such as vessel walls or cellular membranes, allowing for enhanced therapeutic delivery into the target tissues. While enhanced delivery of small (<1nm) molecules has been shown at acoustic pressures below 1MPa both in vitro and in vivo, the delivery efficiency of larger (>100nm) therapeutic carriers into cancer remains unclear and may require a higher pressure for sufficient delivery. Enhanced delivery of larger therapeutic carriers such as FDA approved pegylated poly(lactic-co-glycolic acid) nanoparticles (PLGA-PEG-NP) has significant clinical value because these nanoparticles have been shown to protect encapsulated drugs from degradation in the blood circulation and allow for slow and prolonged release of encapsulated drugs at the target location. In this study, various acoustic parameters were investigated to facilitate the successful delivery of two nanocarriers, a fluorescent semiconducting polymer model drug nanoparticle as well as PLGA-PEG-NP into human colon cancer xenografts in mice. We first measured the cavitation dose produced by various acoustic parameters (pressure, pulse length, and pulse repetition frequency) and microbubble concentration in a tissue mimicking phantom. Next, in vivo studies were performed to evaluate the penetration depth of nanocarriers using various acoustic pressures, ranging between 1.7 and 6.9MPa. Finally, a therapeutic microRNA, miR-122, was loaded into PLGA-PEG-NP and the amount of delivered miR-122 was assessed using quantitative RT-PCR. Our results show that acoustic pressures had the strongest effect on cavitation. An increase of the pressure from 0.8 to 6.9MPa resulted in a nearly 50-fold increase in cavitation in phantom experiments. In vivo, as the pressures increased from 1.7 to 6.9MPa, the amount of nanoparticles deposited in cancer xenografts was increased from 4- to 14-fold, and the median penetration depth of extravasated nanoparticles was increased from 1.3-fold to 3-fold, compared to control conditions without ultrasound, as examined on 3D confocal microscopy. When delivering miR-122 loaded PLGA-PEG-NP using optimal acoustic settings with minimum tissue damage, miR-122 delivery into tumors with ultrasound and microbubbles was 7.9-fold higher compared to treatment without ultrasound. This study demonstrates that ultrasound induced microbubble cavitation can be a useful tool for delivery of therapeutic miR loaded nanocarriers into cancer in vivo.
Collapse
|
24
|
Petit B, Yan F, Bussat P, Bohren Y, Gaud E, Fontana P, Tranquart F, Allémann E. Fibrin degradation during sonothrombolysis – Effect of ultrasound, microbubbles and tissue plasminogen activator. J Drug Deliv Sci Technol 2015. [DOI: 10.1016/j.jddst.2014.12.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
25
|
Tomkins AJ, Schleicher N, Murtha L, Kaps M, Levi CR, Nedelmann M, Spratt NJ. Platelet rich clots are resistant to lysis by thrombolytic therapy in a rat model of embolic stroke. EXPERIMENTAL & TRANSLATIONAL STROKE MEDICINE 2015; 7:2. [PMID: 25657829 PMCID: PMC4318170 DOI: 10.1186/s13231-014-0014-y] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2014] [Accepted: 12/22/2014] [Indexed: 11/21/2022]
Abstract
Background Early recanalization of occluded vessels in stroke is closely associated with improved clinical outcome. Microbubble-enhanced sonothrombolysis is a promising therapy to improve recanalization rates and reduce the time to recanalization. Testing any thrombolytic therapy requires a model of thromboembolic stroke, but to date these models have been highly variable with regards to clot stability. Here, we developed a model of thromboembolic stroke in rats with site-specific delivery of platelet-rich clots (PRC) to the main stem of the middle cerebral artery (MCA). This model was used in a subsequent study to test microbubble-enhanced sonothrombolysis. Methods In Study 1 we investigated spontaneous recanalization rates of PRC in vivo over 4 hours and measured infarct volumes at 24 hours. In Study 2 we investigated tPA-mediated thrombolysis and microbubble-enhanced sonothrombolysis in this model. Results Study 1 demonstrated stable occlusion out to 4 hours in 5 of 7 rats. Two rats spontaneously recanalized at 40 and 70 minutes post-embolism. Infarct volumes were not significantly different in recanalized rats, 43.93 ± 15.44% of the ischemic hemisphere, compared to 48.93 ± 3.9% in non-recanalized animals (p = 0.7). In Study 2, recanalization was not observed in any of the groups post-treatment. Conclusions Site specific delivery of platelet rich clots to the MCA origin resulted in high rates of MCA occlusion, low rates of spontaneous clot lysis and large infarction. These platelet rich clots were highly resistant to tPA with or without microbubble-enhanced sonothrombolysis. This resistance of platelet rich clots to enhanced thrombolysis may explain recanalization failures clinically and should be an impetus to better clot-type identification and alternative recanalization methods. Electronic supplementary material The online version of this article (doi:10.1186/s13231-014-0014-y) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Amelia J Tomkins
- School of Biomedical Sciences & Pharmacy, University of Newcastle, and Hunter Medical Research Institute, Newcastle, Australia
| | - Nadine Schleicher
- Heart and Brain Research Group, Justus-Liebig-University, Giessen and Kerckhoff Clinic, Bad Nauheim, Germany ; Department of Neurology, Justus-Liebig-University, Giessen, Germany ; Department of Cardiac Surgery, Kerckhoff Clinic, Bad Nauheim, Germany
| | - Lucy Murtha
- School of Biomedical Sciences & Pharmacy, University of Newcastle, and Hunter Medical Research Institute, Newcastle, Australia
| | - Manfred Kaps
- Department of Neurology, Justus-Liebig-University, Giessen, Germany
| | - Christopher R Levi
- Hunter New England Local Health District, Newcastle, Australia ; School of Medicine and Public Health, University of Newcastle, and Hunter Medical Research Institute, Newcastle, Australia
| | - Max Nedelmann
- Department of Neurology, Justus-Liebig-University, Giessen, Germany ; Sana Regio Klinkum, Pinneberg, Germany ; Department of Neurology, University Hospital Center Hamburg-Eppendorf, Hamburg, Germany
| | - Neil J Spratt
- School of Biomedical Sciences & Pharmacy, University of Newcastle, and Hunter Medical Research Institute, Newcastle, Australia ; Hunter New England Local Health District, Newcastle, Australia
| |
Collapse
|
26
|
Ultrasound molecular imaging of transient acute myocardial ischemia with a clinically translatable P- and E-selectin targeted contrast agent: correlation with the expression of selectins. Invest Radiol 2014; 49:224-35. [PMID: 24442162 DOI: 10.1097/rli.0000000000000018] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
OBJECTIVE The diagnosis of acute coronary syndrome remains challenging especially in patients without clear symptoms or electrocardiographic and/or biomarker features. A hallmark of ischemia/reperfusion is activation of endothelial cells leading to altered expression of molecular markers, including selectins. In this context, we aimed to validate the value of ultrasound molecular imaging for detecting transient myocardial ischemia by using a clinically translatable dual P- and E-selectin-targeted ultrasound contrast agent (UCA) and microbubble (MB(selectin)). MATERIAL AND METHODS Transient (20 minutes) myocardial ischemia of rat heart was produced by ligation of the left anterior descending coronary artery ligation followed by 2-, 5-, or 24-hour reperfusion. Imaging of the transient ischemic event was achieved by the use of MB(selectin). Performance of this clinically translatable targeted UCA was compared with that of antibody-targeted streptavidin MBs. Finally, immunohistochemistry staining of rat myocardial ischemic tissue was performed to assess expression of selectins accessible to targeted UCA. RESULTS In rats subjected to myocardial ischemia (20 minutes) followed by reperfusion (2 hours), injection of MB(selectin) produced high late phase (ie, 10-minute postinjection) ultrasound molecular imaging enhancement in the myocardium, which colocalized with the ischemic area. Late phase enhancement persisted 5 and 24 hours after reperfusion. Similarly, the use of MBP and MBE, comprising antibodies specific for P- and E-selectin, respectively, showed high late-phase enhancement within the ischemic area compared with remote myocardial tissue. Two and 5 hours after ischemia has resolved, a persistent expression of these 2 selectins was detected. After 24 hours of reperfusion, only MBE produced late phase enhancement within the ischemic myocardium. Immunohistochemical findings revealed that both P- and E-selectin were expressed and accessible on the surface of the activated endothelium 2 and 5 hours after the acute ischemic event, whereas only E-selectin remained accessible after 24 hours. CONCLUSIONS Ultrasound molecular imaging of transient myocardial ischemia using dual selectin-targeted UCA is able to monitor the time course of expression of selectins after resolution of the ischemic event, paving the way for a large clinical diagnostic window.
Collapse
|
27
|
Izamis ML, Efstathiades A, Keravnou C, Leen EL, Averkiou MA. Dynamic contrast-enhanced ultrasound of slaughterhouse porcine livers in machine perfusion. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:2217-2230. [PMID: 25023101 DOI: 10.1016/j.ultrasmedbio.2014.03.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2013] [Revised: 03/28/2014] [Accepted: 03/31/2014] [Indexed: 06/03/2023]
Abstract
The aim of this study was to enable investigations into novel imaging and surgical techniques by developing a readily accessible, versatile liver machine perfusion system. Slaughterhouse pig livers were used, and dynamic contrast-enhanced ultrasound was introduced to optimize the procurement process and provide real-time perfusion monitoring. The system comprised a single pump, oxygenator, bubble trap and two flowmeters for pressure-controlled perfusion of the vessels using an off-the-shelf perfusate at room temperature. Successful livers exhibited homogeneous perfusion in both the portal vein and hepatic artery with dynamic contrast-enhanced ultrasound, which correlated with stable oxygen uptake, bile production and hepatic resistance and normal histology at the end of 3 h of perfusion. Dynamic contrast-enhanced ultrasound revealed perfusion abnormalities invisible to the naked eye, thereby providing context to the otherwise systemic biochemical/hemodynamic measurements and focal biopsy findings. The model developed here is a simple, cost-effective approach for stable ex vivo whole-organ machine perfusion.
Collapse
Affiliation(s)
- Maria-Louisa Izamis
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus
| | | | - Christina Keravnou
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus
| | - Edward L Leen
- Department of Medicine, Imperial College, London, United Kingdom
| | - Michalakis A Averkiou
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus.
| |
Collapse
|
28
|
Kovacs Z, Werner B, Rassi A, Sass JO, Martin-Fiori E, Bernasconi M. Prolonged survival upon ultrasound-enhanced doxorubicin delivery in two syngenic glioblastoma mouse models. J Control Release 2014; 187:74-82. [DOI: 10.1016/j.jconrel.2014.05.033] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2014] [Revised: 05/13/2014] [Accepted: 05/19/2014] [Indexed: 11/29/2022]
|
29
|
Kamaya A, Machtaler S, Safari Sanjani S, Nikoozadeh A, Graham Sommer F, Pierre Khuri-Yakub BT, Willmann JK, Desser TS. New technologies in clinical ultrasound. Semin Roentgenol 2014; 48:214-23. [PMID: 23796372 DOI: 10.1053/j.ro.2013.03.009] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Affiliation(s)
- Aya Kamaya
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA.
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Payen T, Coron A, Lamuraglia M, Le Guillou-Buffello D, Gaud E, Arditi M, Lucidarme O, Bridal SL. Echo-power estimation from log-compressed video data in dynamic contrast-enhanced ultrasound imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1826-1837. [PMID: 23879926 DOI: 10.1016/j.ultrasmedbio.2013.03.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2012] [Revised: 03/20/2013] [Accepted: 03/21/2013] [Indexed: 06/02/2023]
Abstract
Ultrasound (US) scanners typically apply lossy, non-linear modifications to the US data for visualization purposes. The resulting images are then stored as compressed video data. Some system manufacturers provide dedicated software for quantification purposes to eliminate such processing distortions, at least partially. This is currently the recommended approach for quantitatively assessing changes in contrast-agent concentration from clinical data. However, the machine-specific access to US data and the limited set of analysis functionalities offered by each dedicated-software package make it difficult to perform comparable analyses with different US systems. The objective of this work was to establish if linearization of compressed video images obtained with an arbitrary US system can provide an alternative to dedicated-software analysis of machine-specific files for the estimation of echo-power. For this purpose, an Aplio 50 system (Toshiba Medical Systems, Tochigi, Japan), coupled with dedicated CHI-Q (Contrast Harmonic Imaging Quantification) software by Toshiba Medical Systems, was used. Results were compared with two approaches that apply algorithms to estimate relative echo-power from compressed video images: commercially available VueBox software by Bracco Suisse SA (Geneva, Switzerland) and in-laboratory software called PixPower. The echo-power estimated by CHI-Q analysis indicated a strong linear relationship versus agent concentration in vitro (R(2) ≥ 0.9996) for dynamic range (DR) settings of DR60 and DR80, with slopes between 9.22 and 9.57 dB/decade (p = 0.05). These values approach the theoretically predicted dependence of 10.0 dB/decade (equivalent to 3 dB for each concentration doubling). Echo-power estimations obtained from compressed video images with VueBox and PixPower also exhibited strong linear proportionality with concentration (R(2) ≥ 0.9996), with slopes between 9.30 and 9.68 dB/decade (p = 0.05). On an independent in vivo data set (N = 24), the difference in echo-power estimation between CHI-Q and each of the other two approaches was calculated after excluding regions that contain pixels affected by saturated or thresholded pixel values. The mean difference in estimates (expressed in decibels) was -0.25 dB between VueBox and CHI-Q (95% confidence interval: -0.75 to 0.26 dB) and -0.17 dB between PixPower and CHI-Q (95% confidence interval: -0.67 to 0.13 dB). To achieve linearization of data, one of the approaches (VueBox) requires calibration files provided by the software manufacturer for each machine type and setting. The other (PixPower) requires empirical correction of the imaging dynamic range based on ground truth data. These requirements could potentially be removed if US system manufacturers were willing to make relevant information on the applied processing publically available. Reliable echo-power estimation from linearized data would facilitate inclusion of different US systems in multicentric studies and more widespread implementation of emerging techniques for quantitative analysis of contrast ultrasound.
Collapse
|
31
|
Kwan JJ, Kaya M, Borden MA, Dayton PA. Theranostic oxygen delivery using ultrasound and microbubbles. Theranostics 2012; 2:1174-84. [PMID: 23382774 PMCID: PMC3563146 DOI: 10.7150/thno.4410] [Citation(s) in RCA: 73] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2012] [Accepted: 06/08/2012] [Indexed: 11/17/2022] Open
Abstract
Means to overcome tumor hypoxia have been the subject of clinical investigations since the 1960's; however these studies have yet to find a treatment which is widely accepted. It has been known for nearly a century that hypoxic cells are more resistant to radiotherapy than aerobic cells, and tumor hypoxia is a major factor leading to the resistance of tumors to radiation treatment as well as several cytotoxic agents. In this manuscript, the application of ultrasound combined with oxygen-carrier microbubbles is demonstrated as a method to locally increase dissolved oxygen. Microbubbles can also be imaged by ultrasound, thus providing the opportunity for image-guided oxygen delivery. Simulations of gas diffusion and microbubble gas exchange show that small amounts (down to 5 vol%) of a low-solubility osmotic gas can substantially increase microbubble persistence and therefore production rates and stability of oxygen-carrier microbubbles. Simulations also indicate that the lipid shell can be engineered with long-chain lipids to increase oxygen payload during in vivo transit. Experimental results demonstrate that the application of ultrasound to destroy the microbubbles significantly enhances the local oxygen release. We propose this technology as an application for ultrasound image-guided release of oxygen directly to hypoxic tissue, such as tumor sites to enhance radiotherapy.
Collapse
Affiliation(s)
- James J Kwan
- Department of Mechanical Engineering, University of Colorado, Boulder, CO 80309, USA
| | | | | | | |
Collapse
|
32
|
Panje CM, Wang DS, Pysz MA, Paulmurugan R, Ren Y, Tranquart F, Tian L, Willmann JK. Ultrasound-mediated gene delivery with cationic versus neutral microbubbles: effect of DNA and microbubble dose on in vivo transfection efficiency. Am J Cancer Res 2012; 2:1078-91. [PMID: 23227124 PMCID: PMC3516840 DOI: 10.7150/thno.4240] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2012] [Accepted: 05/25/2012] [Indexed: 12/11/2022] Open
Abstract
OBJECTIVE To assess the effect of varying microbubble (MB) and DNA doses on the overall and comparative efficiencies of ultrasound (US)-mediated gene delivery (UMGD) to murine hindlimb skeletal muscle using cationic versus neutral MBs. MATERIALS AND METHODS Cationic and control neutral MBs were characterized for size, charge, plasmid DNA binding, and ability to protect DNA against endonuclease degradation. UMGD of a codon optimized firefly luciferase (Fluc) reporter plasmid to endothelial cells (1 MHz, 1 W/cm², 20% duty cycle, 1 min) was performed in cell culture using cationic, neutral, or no MBs. In vivo UMGD to mouse hindlimb muscle was performed by insonation (1 MHz, 2 W/cm², 50% duty cycle, 5 min) after intravenous administration of Fluc combined with cationic, neutral, or no MBs. Gene delivery efficiency was assessed by serial in vivo bioluminescence imaging. Efficiency of in vivo UMGD with cationic versus neutral MBs was systematically evaluated by varying plasmid DNA dose (10, 17.5, 25, 37.5, and 50 µg) while maintaining a constant MB dose of 1x10(8) MBs and by changing MB dose (1x10(7), 5x10(7), 1x10(8), or 5x10(8) MBs) while keeping a constant DNA dose of 50 µg. RESULTS Cationic and size-matched control neutral MBs differed significantly in zeta potential with cationic MBs being able to bind plasmid DNA (binding capacity of 0.03 pg/MB) and partially protect DNA from nuclease degradation while neutral MBs could not. Cationic MBs enhanced UMGD compared to neutral MBs as well as no MB and no US controls both in cell culture (P < 0.001) and in vivo (P < 0.05). Regardless of MB type, in vivo UMGD efficiency increased dose-dependently with DNA dose and showed overall maximum transfection with 50 µg DNA. However, there was an inverse correlation (ρ = -0.90; P = 0.02) between DNA dose and the degree of enhanced UMGD efficiency observed with using cationic MBs instead of neutral MBs. The delivery efficiency advantage associated with cationic MBs was most prominent at the lowest investigated DNA dose (7.5-fold increase with cationic versus neutral MBs at a DNA dose of 10 µg; P = 0.02) compared to only a 1.4-fold increase at a DNA dose of 50 µg (P < 0.01). With increasing MB dose, overall in vivo UMGD efficiency increased dose-dependently with a maximum reached at a dose of 1x10(8) MBs with no further significant increase with 5x10(8) MBs (P = 0.97). However, compared to neutral MBs, cationic MBs enhanced UMGD efficiency the most at low MB doses. Relative enhancement of UMGD efficiency using cationic over neutral MBs decreased from a factor of 27 for 1x10(7) MBs (P = 0.02) to a factor of 1.4 for 1x10(8) MBs (P < 0.01) and no significant difference for 5x10(8) MBs. CONCLUSIONS Cationic MBs enhance UMGD to mouse skeletal muscle relative to neutral MBs but this is dependent on MB and DNA dose. The enhancement effect of cationic MBs on UMGD efficiency is more evident when lower doses of MBs or DNA are used, whereas the advantage of cationic MBs over neutral MBs is substantially reduced in the presence of excess MBs or DNA.
Collapse
|
33
|
Mulvana H, Browning RJ, Tang MX, Hajnal JV, Eckersley RJ. Albumin coated microbubble optimization: custom fabrication and comprehensive characterization. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1599-1607. [PMID: 22763010 DOI: 10.1016/j.ultrasmedbio.2012.05.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2011] [Revised: 04/26/2012] [Accepted: 05/07/2012] [Indexed: 06/01/2023]
Abstract
Gas microbubbles are used routinely to improve contrast in medical diagnostic imaging. The emerging fields of microbubble-enhanced quantitative imaging and microbubble-enhanced drug delivery have further enhanced the drive toward microbubble characterization and design techniques. The quest to improve efficiency, particularly in the field of drug delivery, presents a requirement to develop methods to manipulate microbubble properties to improve utility. This article presents an investigation in to the feasibility of influencing albumin shelled microbubble properties through the variation of albumin availability during fabrication. Microbubbles were fabricated from albumin suspensions of varying concentration before thorough physical and acoustic characterization. Microbubbles with shells fabricated from a 2% albumin suspension had a greater scattering to attenuation ratio (STAR) than 10% albumin preparations (4.4% and 2.2%, respectively) and approximately double the nonlinear STAR (from 0.7% to 1.5%). The 2% microbubbles also exhibited greater (up to 40%), more violent radial oscillations during high speed imaging than 5% and 10% preparations. The results show that microbubble characteristics can be simply manipulated in the lab and indicate that for a given application this may provide the opportunity to further enhance favorable characteristics.
Collapse
Affiliation(s)
- Helen Mulvana
- Department of Imaging Sciences, Imperial College London, United Kingdom
| | | | | | | | | |
Collapse
|
34
|
Ultrasound Molecular Imaging Contrast Agent Binding to Both E- and P-Selectin in Different Species. Invest Radiol 2012; 47:516-23. [DOI: 10.1097/rli.0b013e31825cc605] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
35
|
Current world literature. Curr Opin Cardiol 2012; 27:556-64. [PMID: 22874129 DOI: 10.1097/hco.0b013e32835793f0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
36
|
Bzyl J, Palmowski M, Rix A, Arns S, Hyvelin JM, Pochon S, Ehling J, Schrading S, Kiessling F, Lederle W. The high angiogenic activity in very early breast cancer enables reliable imaging with VEGFR2-targeted microbubbles (BR55). Eur Radiol 2012; 23:468-75. [DOI: 10.1007/s00330-012-2594-z] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2012] [Revised: 06/16/2012] [Accepted: 07/01/2012] [Indexed: 10/28/2022]
|
37
|
Frinking PJA, Tardy I, Théraulaz M, Arditi M, Powers J, Pochon S, Tranquart F. Effects of acoustic radiation force on the binding efficiency of BR55, a VEGFR2-specific ultrasound contrast agent. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1460-1469. [PMID: 22579540 DOI: 10.1016/j.ultrasmedbio.2012.03.018] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2011] [Revised: 03/08/2012] [Accepted: 03/25/2012] [Indexed: 05/31/2023]
Abstract
This work describes an in vivo study analyzing the effect of acoustic radiation force (ARF) on the binding of BR55 VEGFR2-specific contrast-agent microbubbles in a model of prostatic adenocarcinoma in rat. A commercial ultrasound system was modified by implementing high duty-cycle 3.5-MHz center frequency ARF bursts in a scanning configuration. This enabled comparing the effects of ARF on binding in tumor and healthy tissue effectively in the same field of view. Bubble binding was established by measuring late-phase enhancement in amplitude modulation (AM) contrast-specific imaging mode (4 MHz, 150 kPa) 10 min after agent injection when the unbound bubbles were cleared from the circulation. Optimal experimental conditions, such as agent concentration (0.4 × 10(8)-1.6 × 10(8) bubbles/kg), acoustic pressure amplitude (26-51 kPa) and duty-cycle (20%-95%) of the ARF bursts, were evaluated in their ability to enhance binding in tumor without significantly increasing binding in healthy tissue. Using the optimal conditions (38 kPa peak-negative pressure, 95% duty cycle), ARF-assisted binding of BR55 improved significantly in tumor (by a factor of 7) at a lower agent dose compared with binding without ARF, and it had an insignificant effect on binding in healthy tissue. Thus, the high binding specificity of BR55 microbubbles for targeting VEGFR2 present at sites of active angiogenesis was confirmed by this study. Therefore, it is believed that based on the results obtained in this work, ultrasound molecular imaging using target-specific contrast-agent microbubbles should preferably be performed in combination with ARF.
Collapse
Affiliation(s)
- Peter J A Frinking
- Bracco Suisse SA, Geneva Research Center and Manufacturing Site, Plan-les-Ouates/Geneva, Switzerland.
| | | | | | | | | | | | | |
Collapse
|
38
|
Petit B, Gaud E, Colevret D, Arditi M, Yan F, Tranquart F, Allémann E. In vitro sonothrombolysis of human blood clots with BR38 microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1222-1233. [PMID: 22542261 DOI: 10.1016/j.ultrasmedbio.2012.02.023] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2011] [Revised: 02/22/2012] [Accepted: 02/23/2012] [Indexed: 05/31/2023]
Abstract
Microbubble-mediated sonothrombolysis is a promising approach for ischemic stroke treatment. The aim of this in vitro study was to evaluate a new microbubble (MB) formulation (BR38) for sonothrombolysis and to investigate the involved mechanisms. Human whole-blood clots were exposed to different combinations of recombinant tissue plasminogen activator (rtPA), ultrasound (US) and MB. Ultrasound at 1.6 MHz was used at 150, 300, 600 and 1000 kPa (peak-negative pressure). Thrombolysis efficacy was assessed by measuring clot diameter changes during 60-min US exposure. The rate of clot diameter loss (RDL) in μm/min was determined and clot lysis profiles were analyzed. The most efficient clot lysis (5.9 μm/min) was obtained at acoustic pressures of 600 and 1000 kPa in combination with MB and a low concentration of rtPA (0.3 μg/mL). This is comparable with the rate obtained with rtPA at 3 μg/mL alone (6.6 μm/min, p > 0.05). Clot lysis profiles were shown to be related to US beam profiles and microbubble cavitation.
Collapse
Affiliation(s)
- Bénédicte Petit
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva, Switzerland.
| | | | | | | | | | | | | |
Collapse
|
39
|
A minimally-invasive closed chest myocardial occlusion-reperfusion model in rhesus monkeys (Macaca mulatta): monitoring by contrast-enhanced ultrasound imaging. Int J Cardiovasc Imaging 2011; 28:531-42. [PMID: 21484234 DOI: 10.1007/s10554-011-9859-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2010] [Accepted: 03/29/2011] [Indexed: 10/18/2022]
Abstract
Myocardial infarction is frequently developed in canine and porcine models but exceptionally in non-human primates. The aim of this study was to develop a minimally invasive myocardial ischemic/reperfusion model in the monkey intended to be combined with imaging techniques, in particular myocardial contrast echocardiography (MCE). A balloon-tipped catheter was advanced via the femoral artery into the left anterior descending artery (LAD) under fluoroscopic guidance in ten anaesthetized male rhesus monkeys (Macaca mulatta). The balloon was inflated to completely occlude the vessel. Coronary angiography (CA) was performed to control the reality of the LAD occlusion/reperfusion. The ischemia period was followed by 3-6 h of reperfusion. Myocardial perfusion was evaluated during ischemia and at reperfusion by MCE using a novel ultrasound contrast agent (BR38). Occlusion was successfully induced during 18-50 min in nine out of the ten evaluated monkeys. ST segment elevation indicated myocardial ischemia. MCE showed complete transmural arrest of myocardial blood flow during the ischemia period and no persistent microvascular perfusion defects during reperfusion. A minimally invasive closed-chest model was successfully developed for creating myocardial ischemia in the rhesus monkey (Macaca mulatta). This technique could have an important role in mimicking acute coronary syndrome under physiologically and ethically-acceptable conditions. MCE provides non-invasively information on myocardial perfusion status, information not available from CA.
Collapse
|