1
|
Zhang W, Xie J, Wang M. The effect of delay time after injecting gadobutrol on the diagnosis of endolymphatic hydrops. Magn Reson Imaging 2024; 107:160-163. [PMID: 38176577 DOI: 10.1016/j.mri.2024.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Revised: 12/30/2023] [Accepted: 01/01/2024] [Indexed: 01/06/2024]
Abstract
OBJECTIVES The aim of this study was to reduce the time delay between gadolinium injection and 3D-FLAIR (three-dimensional fluid-attenuated inversion recovery) MRI by using a single dose of intravenous gadobutrol in Menière's disease patients. METHODS 17 patients diagnosed with definite unilateral Meniere's disease underwent 3D-FLAIR MRI scans at 2, 4, and 6 h post-intravenous administration of a single-dose of gadobutrol. The signal intensity ratio of bilateral inner ear, cochlear and vestibular hydrops was measured at 2 h, 4 h and 6 h, while the differences in signal intensity ratio and endolymphatic hydrops were evaluated at three time points. RESULTS The cochlea, vestibule, and semicircular canal exhibit clear structural features with distinct perilymph-endolymph boundaries at 2 h, 4 h, and 6 h. The signal intensity ratio of the affected ear was significantly higher than that of the unaffected ear at 2 h, 4 h, and 6 h. The signal intensity ratio at 4 h and 6 h in both the affected and unaffected ears was significantly higher than that at 2 h, but there was no significant difference between 4 h and 6 h. Cochlear hydrops and vestibular hydrops show no significant differences at these time points, demonstrating excellent consistency. CONCLUSIONS We have demonstrated that 3D-FLAIR images acquired 2 h after intravenous administration of a single-dose gadobutrol are of high quality and equally effective as those obtained at the conventional 4-h time point for diagnosing endolymphatic hydrops in Menière's disease. In clinical practice, the delay time can be safely shortened to 2 h.
Collapse
Affiliation(s)
- Weidong Zhang
- Department of Medical Imaging, Zhengzhou University People's Hospital & Henan Provincial People's Hospital, 7 Weiwu Road, 450000 Zhengzhou, China
| | - Jiapei Xie
- Department of Medical Imaging, Zhengzhou University People's Hospital & Henan Provincial People's Hospital, 7 Weiwu Road, 450000 Zhengzhou, China; Academy of Medical Sciences, Zhengzhou University, Zhengzhou, China
| | - Meiyun Wang
- Department of Medical Imaging, Zhengzhou University People's Hospital & Henan Provincial People's Hospital, 7 Weiwu Road, 450000 Zhengzhou, China; Laboratory of Brain Science and Brain-Like Intelligence Technology, Institute for Integrated Medical Science and Engineering, Henan Academy of Sciences, China.
| |
Collapse
|
2
|
Endler CHJ, Jost G, Pietsch H, Luetkens JA, Keil VC, Willinek WA, Attenberger UI, Hadizadeh DR. Effect of Contrast Agent Dose Reduction on Vascular Enhancement and Image Quality in Thoracoabdominal Dynamic 3-Dimensional Magnetic Resonance Angiography: A Systematic Intraindividual Analysis in Pigs. Invest Radiol 2022; 57:689-695. [PMID: 35510876 DOI: 10.1097/rli.0000000000000882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE High spatial and temporal resolution contrast-enhanced magnetic resonance angiography (MRA) with gadolinium-based contrast agents (GBCAs) at standard dose offers both detailed anatomic information on both arterial and venous vessels and hemodynamic characteristics. Several preclinical and clinical dynamic 3-dimensional (3D) MRA studies that focused on arterial vessels only proposed that high image quality may also be achieved with significantly reduced GBCA doses, calling into question the need to use standard doses. A systematic analysis of GBCA doses and resulting image quality for both arteries and veins has not yet been performed. The purpose of this study was therefore to systematically analyze dose-dependent vascular enhancements in dynamic 3D-MRA of the thoracoabdominal vasculature at 1.5 T in an animal model to determine the optimal contrast agent protocol for optimized vascular assessment. MATERIALS AND METHODS The vascular enhancement in thoracoabdominal dynamic 3D-MRA (time-resolved angiography with interleaved stochastic trajectories, TWIST at 1.5 T) was interindividually and intraindividually compared in 5 anesthetized Göttingen minipigs using gadobutrol at the standard dose (0.1 mmol/kg body weight, ie, 0.1 mL/kg) and at reduced doses (0.08, 0.06, 0.04, 0.02 mmol/kg) in a randomized order. All injections were performed at 2 mL/s followed by 20 mL saline. Images were quantitatively analyzed, measuring signal intensities in 5 regions that covered the passage of the GBCA through the body at different representative stages of circulation (pulmonary, arterial, and venous system). The evaluation of GBCA dose-dependent signal intensity changes in the different vascular regions was performed by linear regression analysis.The qualitative image analysis of dynamic 3D-MRA by 3 independent radiologists included the visibility of 25 arterial and venous vessel segments at different stages of GBCA passage. Possible quality losses were statistically tested by comparing image quality ratings at the reduced dose with that of the standard dose using Friedman test followed by Dunn post hoc test for multiple comparison. Significance was stated at P < 0.05. RESULTS Quantitative analysis revealed shorter time-to-peak intervals and bolus durations in line with decreasing GBCA dose and volume in all vessels. Although the peak signal was almost independent of the administered GBCA dose at the level of the pulmonary trunk, a linear signal decrease in the abdominal aorta ( r2 = 0.96), the renal arteries ( r2 = 0.99), the inferior vena cava ( r2 = 0.99), and the portal vein ( r2 = 0.97) was observed. Cumulative analysis of arterial segments revealed significantly lower image quality at doses below 40% of the standard dose, whereas in venous segments, significantly lower image quality was observed at doses below 60% of the standard dose. CONCLUSIONS In dynamic 3D-MRA at 1.5 T, dose reduction leads to a signal loss that is most pronounced in the venous system and results in significantly lower image quality according to the dose and vessels of interest. Careful dose reduction is thus required according to the specific diagnostic needs. For dynamic 3D-MRA of the arterial and venous system, GBCA doses of at least 60% of the standard dose up to the full dose are preferable, whereas 40% of the standard dose seems feasible if only the arterial system is to be imaged.
Collapse
Affiliation(s)
| | - Gregor Jost
- MR and CT Contrast Media Research, Bayer AG, Berlin
| | | | | | | | - Winfried Albert Willinek
- Center for Radiology, Neuroradiology, Sonography and Nuclear Medicine, Krankenhaus der Barmherzigen Brüder, Trier, Germany
| | | | - Dariusch Reza Hadizadeh
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn
| |
Collapse
|
3
|
Cerne JW, Pathrose A, Singer AM, Moore JE, Serhal A, Aouad P, Umair M, Ragin A, Allen BD, Avery R, Markl M, Carr JC. MRA of the Supraaortic Vasculature: Comparison of Gadobutrol and Gadoterate Meglumine at 1.5 T. J Magn Reson Imaging 2021; 56:440-449. [PMID: 34953154 DOI: 10.1002/jmri.28044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 12/14/2021] [Accepted: 12/14/2021] [Indexed: 11/08/2022] Open
Abstract
BACKGROUND Gadobutrol (GB) and gadoterate meglumine (GM) are contrast agents used for contrast-enhanced magnetic resonance angiography (CEMRA). Supraaortic vasculature (SAV) CEMRAs are used to evaluate stroke risk and neurologic symptoms. There is a need to compare the SAV CEMRA image quality obtained with GB and GM. PURPOSE To intra-individually compare MRA images obtained with equimolar GB and GM at 1.5 T in the SAV. STUDY TYPE Prospective, crossover. POPULATION Twenty-eight subjects (54 ± 13 years; 17 female). FIELD STRENGTH/SEQUENCE 1.5 T; three-dimensional (3D) gradient recalled echo. ASSESSMENT Quantitative image quality was measured by normalized signal intensity (SIn ) [SIn = SI blood/SD blood] and contrast ratio (CR) [CR = SI blood/SI muscle], determined by an observer (JWC) with 1 year of vascular imaging experience. Three radiologists (AS, PA, and MU) with (5, 5, and 6 years of) vascular imaging experience evaluated image quality by Likert-scale ratings (of image impression, wall conspicuity, and artifact absence). STATISTICAL TESTS SIn and CR were compared with paired t-tests or Wilcoxon signed-rank tests and Bland-Altman plots. Qualitative ratings were compared with Wilcoxon signed-rank test. RESULTS No significant difference in SIn was found between GB and GM. CRs with GB were significantly higher than GM at the right common carotid (6.9 ± 2.5 vs. 4.8 ± 1), left internal carotid (7.3 ± 2 vs. 4.4 ± 1.2), right internal carotid (7.7 ± 2.2 vs. 5 ± 1.1), and left vertebral (6.6 ± 2.2 vs. 4.5 ± 1.1) arteries. Bland-Altman plots showed relatively greater differences between GB and GM at higher CRs and SIn s. GM showed significantly higher artifact than GB (3.56 ± 0.52 vs. 3.36 ± 0.46) and significantly lower overall image quality (10.73 ± 1.45 vs. 11.26 ± 1.58) at the left vertebral artery. DATA CONCLUSION At 1.5 T and equimolar demonstration, GB (0.1 mL/kg, i.e., 0.1 mmol/kg) showed higher CRs in the SAV compared to GM (0.2 mL/kg, i.e., 0.1 mmol/kg) at most vessels. Subjective image quality was not significantly different between the two agents for most vessels. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- John W Cerne
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Ashitha Pathrose
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Alyssa M Singer
- Tulane University School of Medicine, New Orleans, Louisiana, USA
| | - Jackson E Moore
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University McCormick School of Engineering and Applied Science, Evanston, Illinois, USA
| | - Ali Serhal
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Pascale Aouad
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Muhammad Umair
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Ann Ragin
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Bradley D Allen
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Ryan Avery
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Michael Markl
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University McCormick School of Engineering and Applied Science, Evanston, Illinois, USA
| | - James C Carr
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| |
Collapse
|
4
|
Sato E, Yoshida S, Takeda K, Yoshida R, Sato Y, Yoshioka K, Moriyama H, Hagiwara O, Matsukiyo H, Enomoto T, Watanabe M. Whole cancer-region enhancement using meglumine-gadopentetate-glucose solution and 7.0-T magnetic resonance imaging. Magn Reson Imaging 2021; 81:10-16. [PMID: 33901583 DOI: 10.1016/j.mri.2021.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Revised: 03/22/2021] [Accepted: 04/21/2021] [Indexed: 11/25/2022]
Abstract
To visualize whole cancerous region including hypoxic cancer without radiation exposure, we developed meglumine-gadopentetate-glucose solution for 7.0-T magnetic resonance imaging. The infusion solution consists of meglumine-gadopentetate and glucose solutions, and these solutions are mixed before the vein drip infusion. We used readily available solutions, and the concentrations of the meglumine-gadopentetate and glucose solutions were 37.14 and 5.0%, respectively. In the first and second experiments, vein infusions were conducted from a rabbit ear using meglumine-gadopentetate-saline and meglumine-gadopentetate-glucose solutions, and T1 weighted imaging was performed to visualize cancerous region. Using the meglumine-gadopentetate saline, it was not difficult to image cancer-growth regions with new blood vessels. Using the meglumine-gadopentetate-glucose solution, the signal intensity of whole cancerous region including hypoxic cancer substantially increased. The visualizing duration for the meglumine gadopentetate glucose was beyond 90 min, and the rabbit survived after the infusion. The signal intensity in the hypoxic cancer was increasing until 90 min using the meglumine-gadopentetate-glucose solution, since the meglumine-gadopentetate molecules were absorbed into almost the whole cancerous region along with glucose-molecule flows.
Collapse
Affiliation(s)
- Eiichi Sato
- Department of Physics, Iwate Medical University, 1-1-1 Idaidori, Yahaba, Iwate 028-3694, Japan.
| | - Sohei Yoshida
- Department of Radiology, School of Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba, Iwate 028-3694, Japan
| | - Kota Takeda
- Central Radiation Department, Iwate Medical University Hospital, 2-1-1 Idaidori, Yahaba, Iwate 028-3694, Japan
| | - Ryoko Yoshida
- Department of Physics, Iwate Medical University, 1-1-1 Idaidori, Yahaba, Iwate 028-3694, Japan
| | - Yuichi Sato
- Central Radiation Department, Iwate Medical University Hospital, 2-1-1 Idaidori, Yahaba, Iwate 028-3694, Japan
| | - Kunihiro Yoshioka
- Department of Radiology, School of Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba, Iwate 028-3694, Japan
| | - Hodaka Moriyama
- Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan
| | - Osahiko Hagiwara
- Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan
| | - Hiroshi Matsukiyo
- Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan
| | - Toshiyuki Enomoto
- Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan
| | - Manabu Watanabe
- Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan
| |
Collapse
|
5
|
Xie J, Zhang W, Zhu J, Hui L, Li S, Zhang B. Comparison of inner ear MRI enhancement in patients with Meniere's disease after intravenous injection of gadobutrol, gadoterate meglumine, or gadodiamide. Eur J Radiol 2021; 139:109682. [PMID: 33813284 DOI: 10.1016/j.ejrad.2021.109682] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 03/01/2021] [Accepted: 03/18/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE To compare the enhancement results of three gadolinium contrast agents in the inner ear of patients with Meniere's disease 4 h after intravenous injection of gadobutrol, gadoterate meglumine, or gadodiamide. METHODS We enrolled 60 patients with a definitive diagnosis of unilateral Meniere's disease and divided them into three groups of 20 patients; each group received a double dose of gadobutrol, gadoterate meglumine, or gadodiamide. The postcontrast signal intensity of the basal cochlear turn was scored quantitatively, and qualitative visual evaluation of the cochlea, vestibule and semi-circular canals was also performed. The results of both evaluations were compared between the three patient groups. RESULTS The cochlear basal turn signal intensity of the gadobutrol group was significantly higher than that of the gadoterate meglumine and gadodiamide groups; however, no significant difference was observed between the gadoterate meglumine and gadodiamide groups. The intensity of visualization of the semi-circular canals was significantly better in the bilateral gadobutrol group than in the gadoterate meglumine and gadodiamide groups; however, there was no significant difference in terms of the intensity of visualization of the semi-circular canals between the gadoterate meglumine and gadodiamide groups. There were no significant differences in the intensity of visualization of the cochlea and vestibule among the three groups. CONCLUSIONS Compared with gadoterate meglumine and gadodiamide, gadobutrol can provide a higher degree of perilymphatic enhancement and better anatomical details of the semi-circular canals in the ears of patients with Meniere's disease.
Collapse
Affiliation(s)
- Jiapei Xie
- Department of Radiology, The Fourth Affiliated Hospital of China Medical University, Shenyang, Liaoning 110032, China.
| | - Weidong Zhang
- Department of Radiology, The First Hospital of China Medical University, Shenyang, Liaoning 110001, China.
| | - Jingyi Zhu
- Department of Radiology, The First Hospital of China Medical University, Shenyang, Liaoning 110001, China.
| | - Lian Hui
- Department of Otorhinolaryngology, The First Hospital of China Medical University, Shenyang, Liaoning 110001, China.
| | - Songbai Li
- Department of Radiology, The First Hospital of China Medical University, Shenyang, Liaoning 110001, China.
| | - Bo Zhang
- Department of Radiology, The First Hospital of China Medical University, Shenyang, Liaoning 110001, China.
| |
Collapse
|
6
|
Noda Y, Goshima S, Namimoto T, Shinkawa N, Nakagawa M, Kajita K, Kawada H, Kawai N, Tanahashi Y, Matsuo M, Bae KT, Hirai T, Yamashita Y. Simultaneous acquisition of MR angiography and diagnostic images of abdomen at view-sharing multiarterial phases and comparing the effect of two different contrast agents. J Magn Reson Imaging 2017; 48:102-110. [PMID: 29247585 DOI: 10.1002/jmri.25925] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Accepted: 11/21/2017] [Indexed: 01/19/2023] Open
Abstract
BACKGROUND Simultaneous acquisition of magnetic resonance angiography (MRA) and diagnostic images is challenging in contrast-enhanced upper abdominal MRI. PURPOSE To evaluate the image quality of MRA of the abdomen acquired simultaneously with diagnostic MR images, and to compare the contrast effect, conspicuity of aortic branches, and pancreatic lesions in MRA between gadobutrol and gadoterate meglumine. STUDY TYPE Prospective. POPULATION Eighty-eight patients with known and suspected upper abdominal disease. FIELD STRENGTH/SEQUENCES 3T/4D-eTHRIVE (T1 -weighted fat-suppressed 3D fast gradient echo) for multiarterial phase imaging. ASSESSMENT The artery-to-muscle signal intensity ratio (SIR), conspicuity of aortic branches on the axial, maximum intensity projection (MIP), and volume-rendered (VR) images, and conspicuity of focal pancreatic lesions were compared between gadobutrol and gadoterate meglumine. The diameters of aortic branches were measured on axial MRA and computed tomography angiography (CTA) images and then compared. STATISTICAL TESTS Quantitative and qualitative data were assessed with the Mann-Whitney U-test. The diameters of aortic branches between MRA and CTA were compared with a Spearman rank correlation test. RESULTS View-sharing multiarterial phase imaging was successfully performed in all patients. The SIRs of common hepatic artery (P = 0.0051) and left renal artery (RA) (P = 0.045), vascular conspicuities of right and left hepatic arteries (P = 0.010 and 0.030) and right and left RAs on axial (P = 0.0065 and 0.036), and that of gastroduodenal artery on MIP (P = 0.039) with gadobutrol were significantly higher than those with gadoterate meglumine. The conspicuity of focal pancreatic lesions were comparable between the gadobutrol and gadoterate meglumine (P = 0.73). The vascular diameters on MRA and CTA were strongly correlated in all aortic branches (r = 0.842-0.942, P < 0.0001). DATA CONCLUSION High-quality MRA of the abdomen was obtained simultaneously with the diagnostic MR images using view-sharing multiarterial phase imaging that also demonstrated comparable image quality between gadobutrol and gadoterate meglumine. LEVEL OF EVIDENCE 2 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.
Collapse
Affiliation(s)
| | | | - Tomohiro Namimoto
- Department of Diagnostic Radiology, Faculty of Medicine, Kumamoto University, Kumamoto, Japan
| | - Norihiro Shinkawa
- Department of Diagnostic Radiology, Faculty of Life Sciences, University of Miyazaki, Miyazaki, Japan
| | - Masataka Nakagawa
- Department of Diagnostic Radiology, Faculty of Medicine, Kumamoto University, Kumamoto, Japan
| | | | | | | | | | | | - Kyongtae T Bae
- Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Toshinori Hirai
- Department of Diagnostic Radiology, Faculty of Life Sciences, University of Miyazaki, Miyazaki, Japan
| | - Yasuyuki Yamashita
- Department of Diagnostic Radiology, Faculty of Medicine, Kumamoto University, Kumamoto, Japan
| |
Collapse
|
7
|
Wu G, Jin T, Li T, Morelli J, Li X. High spatial resolution time-resolved magnetic resonance angiography of lower extremity tumors at 3T: Comparison with computed tomography angiography. Medicine (Baltimore) 2016; 95:e4894. [PMID: 27631262 PMCID: PMC5402605 DOI: 10.1097/md.0000000000004894] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The aim of this study was to compare diagnostic value of high spatial resolution time-resolved magnetic resonance angiography with interleaved stochastic trajectory (TWIST) using Gadobutrol to Computed tomography angiography (CTA) for preoperative evaluation of lower extremity tumors.This prospective study was approved by the institutional review board. Fifty consecutive patients (31 men, 19 women, age range 18-80 years, average age 42.7 years) with lower extremity tumors underwent TWIST magnetic resonance angiography (MRA) and CTA. Digital subtraction angiography was available for 8 patients. Image quality of MRA was compared with CTA by 2 radiologists according to a 4-point Likert scale. Arterial involvement by tumor was compared using kappa test between MRA and CTA. The ability to identify feeding arteries and arterio-venous fistulae (AVF) was compared using Wilcoxon signed rank test and McNemar test, respectively.Image quality of MRA and CTA was rated without a statistically significant difference (3.88 ± 0.37 vs. 3.97 ± 0.16, P = 0.135). Intramodality agreement was high for the identification of arterial invasion (kappa = 0.806 ± 0.073 for Reader 1, kappa = 0.805 ± 0.073 for Reader 2). Readers found AVF in 27 of 50 MRA cases and 14 of 50 CTA cases (P < 0.001). Mean feeding arteries identified with MRA were significantly more than that with CTA (2.08 ± 1.72 vs. 1.62 ± 1.52, P = .02).TWIST MRA is a reliable imaging modality for the assessment of lower extremity tumors. TWIST MRA is comparable to CTA for the identification of AVF and feeding arteries.
Collapse
Affiliation(s)
- Gang Wu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology
| | - Teng Jin
- Department of Radiology, Wuhan NO.1 Hospital, Wuhan, Hubei, China
| | - Ting Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology
| | | | - Xiaoming Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology
- Correspondence: Xiaoming Li, No.1095 Jiefang Avenue, Tongji Hospital, Hankou, Wuhan, Hubei 430030, China (e-mail: )
| |
Collapse
|
8
|
Park M, Lee HS, Kim H, Oh SH, Lee JH, Suh MW. Differences in perilymphatic space enhancement and adverse inflammatory reaction after intratympanic injection of two different gadolinium agents: A 9.4-T magnetic resonance imaging study. Hear Res 2016; 333:118-126. [PMID: 26795351 DOI: 10.1016/j.heares.2015.10.022] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Revised: 09/30/2015] [Accepted: 10/14/2015] [Indexed: 09/30/2022]
Abstract
PURPOSE To compare the inner ear enhancement after intratympanic injection of two widely used gadolinium (Gd) agents by 9.4 T micro-magnetic resonance imaging (MRI) and to investigate the effects of Gd on the inner ear. METHODS Twelve ears of six rats received intratympanic administration of 1/5 diluted Gd agents: gadoterate meglumine (Gd-DTPA) for the left ear and gadodiamide (Gd-DTPA-BMA) for the right ear. MRI was performed every 30 min from 1 to 4 h after administration. The normalized signal intensity was evaluated by quantitative analysis at each cochlear fluid compartment. Eight, six, and seven ears treated with Gd-DTPA, Gd-DPTA-BMA, and nothing as controls, respectively, were processed for histological evaluation after MRI. After hematoxylin & eosin staining, adverse inflammatory reactions were evaluated for turbid aggregation and lymphocytes. RESULTS The perilymphatic enhancement of Gd-DTPA was superior to that of Gd-DTPA-BMA regardless of cochlear turn, compartment, and time point. Inflammatory reactions were found in 4/8 (50.0%) and 4/6 (66.6%) ears administered Gd-DTPA and Gd-DTPA-BMA, respectively. Regardless of the contrast agent used, inflammatory reactions were most definite in the scala tympani of the basal turn, i.e., near the round window. Slightly greater inflammatory reactions were observed in ears injected with Gd-DTPA-BMA compared to Gd-DTPA although the difference was not statistically significant. No inflammatory reaction was observed in any of the seven controls. The auditory brainstem response threshold was 11.8 ± 2.5 dB SPL before IT Gd injection and it did not change for up to 5 days (15.4 ± 6.6 dB SPL) post-injection. CONCLUSIONS Gd-DTPA was superior to Gd-DTPA-BMA for visualization of the inner ear. Administration of diluted Gd agents intratympanically may induce considerable inflammatory reactions in the inner ear.
Collapse
Affiliation(s)
- Mina Park
- Department of Otorhinolaryngology-Head and Neck Surgery and Healthcare Research Institute, Healthcare System Gangnam Center, Seoul National University Hospital, Seoul, Republic of Korea; Department of Translational Biomedical Research, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Ho Sun Lee
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Hospital, Seoul, Republic of Korea
| | - Hyeonjin Kim
- Radiology, Seoul National University Hospital, Seoul, Republic of Korea; Department of Biomedical Sciences, Seoul National University, Seoul, Republic of Korea
| | - Seung Ha Oh
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Hospital, Seoul, Republic of Korea; Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University College of Medicine, Seoul, Republic of Korea; Sensory Organ Research Institute, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Jun Ho Lee
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Hospital, Seoul, Republic of Korea; Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University College of Medicine, Seoul, Republic of Korea; Sensory Organ Research Institute, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Myung-Whan Suh
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Hospital, Seoul, Republic of Korea; Sensory Organ Research Institute, Seoul National University Medical Research Center, Seoul, Republic of Korea.
| |
Collapse
|
9
|
Wu G, Jin T, Li T, Li X. RETRACTED: The diagnostic value of time-resolved MR angiography with Gadobutrol at 3T for preoperative evaluation of lower extremity tumors: Comparison with computed tomography angiography. Eur J Radiol Open 2016; 3:239-44. [PMID: 27622202 PMCID: PMC5009234 DOI: 10.1016/j.ejro.2016.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Accepted: 08/24/2016] [Indexed: 11/26/2022] Open
Abstract
Purpose To evaluate the diagnostic value of time resolved magnetic resonance angiography with interleaved stochastic trajectory (TWIST) using Gadobutrol for preoperative evaluation of lower extremity tumors. Materials and methods This prospective study was approved by the local Institutional Review Board. 50 consecutive patients (31 men, 19 women, age range 18–80 years, average age 42.7 years) with lower extremity tumors underwent TWIST and computed tomography angiography (CTA). Image quality of TWIST and CTA were evaluated by two radiologists according to a 4-point scale. The degree of arterial stenosis caused by tumor was assessed using TWSIT and CTA separately, and the intra-modality agreement was determined using a kappa test. The number of feeding arteries identified by TWIST was compared with that by CTA using Wilcoxon signed rank test. The ability to identify arterio-venous fistulae (AVF) were compared using a chi-square test. Results Image quality of TWIST and CTA were rated as 3.88 ± 0.37 and 3.97 ± 0.16, without statistically significant difference (P = 0.135). Intra-modality agreement was excellent for the assessment of arterial stenosis (kappa = 0.806 ± 0.073 for Reader 1, kappa = 0.805 ± 0.073 for Reader 2). Readers identified AVF with TWIST in 27 of 50 cases, and identified AVF with CTA in 14 of 50 (P < 0.001). Mean feeding arteries identified with TWIST was significantly more than that with CTA (2.08 ± 1.72 vs 1.62 ± 1.52, P = 0.02). Conclusion TWIST is a reliable imaging modality for the assessment of lower extremity tumors. TWIST is comparable to CTA for the identification of AVF and feeding arteries.
Collapse
Affiliation(s)
- Gang Wu
- Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiology, Wuhan, Hubei, China
| | - Teng Jin
- Wuhan NO.1 Hospital, Department of Radiology, Wuhan, Hubei, China
| | - Ting Li
- Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiology, Wuhan, Hubei, China
| | - Xiaoming Li
- Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiology, Wuhan, Hubei, China
- Corresponding author. No.1095 Jiefang Avenue, Tongji Hospital, Hankou, Wuhan, Hubei, China.Tongji HospitalTongji Medical CollegeHuazhong University of Science and TechnologyDepartment of RadiologyWuhanHubeiChina
| |
Collapse
|
10
|
Park M, Lee HS, Choi JJ, Kim H, Lee JH, Oh SH, Suh MW. Diverse patterns of perilymphatic space enhancement in the rat inner ear after intratympanic injection of two different types of gadolinium: a 9.4-tesla magnetic resonance study. Audiol Neurootol 2015; 20:112-116. [PMID: 25765053 DOI: 10.1159/000368666] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2014] [Accepted: 09/22/2014] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE To compare the quality of perilymphatic enhancement in the rat inner ear after intratympanic injection of two types of gadolinium with a 9.4-tesla micro-MRI. MATERIALS AND METHODS Gadolinium was injected into the middle ear in 6 Sprague-Dawley rats via the transtympanic route. The left ear was injected with Gd-DO3A-butrol first, and then the right ear was injected with Gd-DOTA. MR images of the inner ear were acquired 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, and 4 h after intratympanic (IT) injection using an Agilent MRI system 9.4T/160/AS. The normalized signal intensity was quantitatively analyzed at the scala vestibuli (SV), scala media, and scala tympani (ST) using a Marosis M-view system. Then the normalized signal intensities (SIs) were compared between the two contrast agents. RESULTS For Gd-DO3A-butrol, the SI was as low as 1.0-1.5 throughout 1-4 h at the SV and ST of the basal turn. The maximum SI was 1.5 ± 0.5 at the SV (2 h) and 1.3 ± 0.5 at the ST (2 h). For Gd-DOTA, the 1-hour postinjection SI at the basal turn was 2.5 ± 0.5 at the SV, 1.6 ± 0.3 at the ST, and 1.2 ± 0.3 at the scala media. In the apical turn, the maximum SI was reached after 2.5 h. The maximum SI in the apical turn was 1.8 ± 0.4 at the SV (3.5 h), 1.8 ± 0.4 at the ST (4 h), and 1.4 ± 0.3 at the scala media (4 h). CONCLUSIONS We were able to clearly visualize and separate the ST and SV using IT Gd and 9.4-tesla micro-MRI. We recommend using Gd-DO3A-butrol over Gd-DOTA and to perform the MRI 2.5 h after using IT Gd in the rat inner ear.
Collapse
|
11
|
Intraindividual quantitative and qualitative comparison of gadopentetate dimeglumine and gadobutrol in time-resolved contrast-enhanced 4-dimensional magnetic resonance angiography in minipigs. Invest Radiol 2015; 49:457-64. [PMID: 24598442 DOI: 10.1097/rli.0000000000000036] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The concentration and relaxivities of contrast agents affect quantitative and qualitative image quality in contrast-enhanced time-resolved 4-dimensional magnetic resonance angiography (4D-MRA). Gadobutrol has a high relaxivity and is the only gadolinium (Gd)-based contrast agent approved for clinical use at a 1 M concentration. This promises to confer superior bolus characteristics by generating a steeper and shorter bolus with a higher peak Gd concentration. The purpose of this study was to quantitatively examine bolus characteristics of 1 M gadobutrol compared with 0.5 M gadopentetate dimeglumine and to evaluate image quality in thoracoabdominal 4D-MRA. MATERIALS AND METHODS A total of 7 Goettingen minipigs received dynamic computed tomography (CT) on a clinical 64-slice CT (transverse slices, 80 kV, 20 seconds, 0.3 s/dynamic frame) and 4D-MRA (time-resolved imaging with stochastic trajectories; 1. transverse slices, 30 seconds, 0.49 s/frame; 2. coronal slices, 70 seconds, 1.3 s/frame) on a 1.5-T clinical whole-body magnetic resonance imaging under general anesthesia using gadopentetate dimeglumine and gadobutrol in an intraindividual comparative study. Computed tomography attenuations were converted into Gd concentrations on the basis of previous phantom experiments. Quantitative analysis included measurements of the full width at half maximum, time-to-peak intervals, and peak of each bolus in dynamic CT and transverse 4D-MRA. These studies were carried out at equivalent contrast agent flow rates of 1 mL/s. Quantitative analysis (7 arteries and veins) and qualitative image analysis were performed on coronal thoracoabdominal 4D-MRA studies carried out at flow rates of 1 mL/s and, in the case of gadopentetate dimeglumine, also at molarity-adjusted flow rates of 2 mL/s. RESULTS The bolus in both transverse 4D-MRA and dynamic CT was significantly narrower (full width at half maximum), earlier (time to peak), and higher (signal intensity enhancement in 4D-MRA, Gd concentration in dynamic CT) when using gadobutrol instead of gadopentetate dimeglumine at a flow rate of 1.0 mL/s (P = 0.008-< 0.0001). In thoracoabdominal 4D-MRA, the signal intensity level and overall image quality were highest in examinations with gadobutrol, followed by examinations with gadopentetate dimeglumine at flow rates of 2 mL/s, and lowest in examinations with gadopentetate dimeglumine at flow rates of 1 mL/s. CONCLUSIONS A more compact bolus shape was observed after administration of gadobutrol compared with gadopentetate dimeglumine in minipigs. This was demonstrated both in 4D-MRA, where Gd concentration, relaxivity, and the image-acquisition technique play a role, and in CT, where the signal intensity depends only on the Gd concentration. The overall image quality was rated higher in examinations with 1.0 M gadobutrol than with 0.5 M gadopentetate dimeglumine.
Collapse
|
12
|
Budjan J, Ong M, Riffel P, Morelli JN, Michaely HJ, Schoenberg SO, Haneder S. CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE) for dynamic liver imaging: Comparison of gadoterate meglumine, gadobutrol and gadoxetic acid. Eur J Radiol 2014; 83:2007-12. [PMID: 25172427 DOI: 10.1016/j.ejrad.2014.08.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Revised: 07/08/2014] [Accepted: 08/07/2014] [Indexed: 11/17/2022]
Affiliation(s)
- Johannes Budjan
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim-Heidelberg University, Mannheim, Germany.
| | - Melissa Ong
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim-Heidelberg University, Mannheim, Germany
| | - Philipp Riffel
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim-Heidelberg University, Mannheim, Germany
| | - John N Morelli
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Henrik J Michaely
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim-Heidelberg University, Mannheim, Germany
| | - Stefan O Schoenberg
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim-Heidelberg University, Mannheim, Germany
| | - Stefan Haneder
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim-Heidelberg University, Mannheim, Germany
| |
Collapse
|
13
|
Assessment of Combination of Contrast-Enhanced Magnetic Resonance Imaging and Positron Emission Tomography/Computed Tomography for Evaluation of Ovarian Masses. Invest Radiol 2014; 49:524-31. [DOI: 10.1097/rli.0000000000000050] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
14
|
Morelli JN, Gerdes CM, Schmitt P, Ai T, Saettele MR, Runge VM, Attenberger UI. Technical considerations in MR angiography: An image-based guide. J Magn Reson Imaging 2013; 37:1326-41. [DOI: 10.1002/jmri.24174] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2012] [Accepted: 03/20/2013] [Indexed: 11/09/2022] Open
|
15
|
A historical overview of magnetic resonance imaging, focusing on technological innovations. Invest Radiol 2013; 47:725-41. [PMID: 23070095 DOI: 10.1097/rli.0b013e318272d29f] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Magnetic resonance imaging (MRI) has now been used clinically for more than 30 years. Today, MRI serves as the primary diagnostic modality for many clinical problems. In this article, historical developments in the field of MRI will be discussed with a focus on technological innovations. Topics include the initial discoveries in nuclear magnetic resonance that allowed for the advent of MRI as well as the development of whole-body, high field strength, and open MRI systems. Dedicated imaging coils, basic pulse sequences, contrast-enhanced, and functional imaging techniques will also be discussed in a historical context. This article describes important technological innovations in the field of MRI, together with their clinical applicability today, providing critical insights into future developments.
Collapse
|
16
|
Kramer JH, Arnoldi E, François CJ, Wentland AL, Nikolaou K, Wintersperger BJ, Grist TM. Dynamic and static magnetic resonance angiography of the supra-aortic vessels at 3.0 T: intraindividual comparison of gadobutrol, gadobenate dimeglumine, and gadoterate meglumine at equimolar dose. Invest Radiol 2013; 48:121-8. [PMID: 23211552 PMCID: PMC3818529 DOI: 10.1097/rli.0b013e31827752b4] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE The purpose of this study was the intraindividual comparison of a 1.0 M and two 0.5 M gadolinium-based contrast agents (GBCA) using equimolar dosing in dynamic and static magnetic resonance angiography (MRA) of the supra-aortic vessels. MATERIALS AND METHODS In this institutional review board-approved study, a total of 20 healthy volunteers (mean ± SD age, 29 ± 6 years) underwent 3 consecutive supra-aortic MRA examinations on a 3.0 T magnetic resonance system. The order of GBCA (Gadobutrol, Gadobenate dimeglumine, and Gadoterate meglumine) was randomized with a minimum interval of 48 hours between the examinations. Before each examination and 45 minutes after each examination, circulatory parameters were recorded. Total GBCA dose per MRA examination was 0.1 mmol/kg with a 0.03 mmol/kg and 0.07 mmol/kg split for dynamic and static MRA, respectively, injected at a rate of 2 mL/s. Two blinded readers qualitatively assessed static MRA data sets independently using pairwise rankings (superior, inferior, and equal). In addition, quantitative analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) evaluation as well as vessel sharpness analysis of static MRA using an in-house-developed semiautomated tool. Dynamic MRA was evaluated for maximal SNR. Statistical analysis was performed using the Cohen κ, the Wilcoxon rank sum tests, and mixed effects models. RESULTS No significant differences of hemodynamic parameters were observed. In static MRA, Gadobutrol was rated superior to Gadoterate meglumine (P < 0.05) and equal to Gadobenate dimeglumine (P = 0.06) with good to excellent reader agreement (κ, 0.66-0.83). In static MRA, SNR was significantly higher using 1.0 M Gadobutrol as compared with either 0.5 M agent (P < 0.05 and P < 0.05) and CNR was significantly higher as compared with Gadoterate meglumine (P < 0.05), whereas CNR values of Gadobutrol data sets were not significantly different as compared with Gadobenate dimeglumine (P = 0.13). Differences in CNR between Gadobenate dimeglumine and Gadoterate meglumine were not significant (P = 0.78). Differences in vessel sharpness between the different GBCAs were also not significant (P > 0.05). Maximal SNR in dynamic MRA using Gadobutrol was significantly higher than both comparators at the level of the proximal and distal internal carotid artery (P < 0.05 and P < 0.05; P < 0.05 and P < 0.05). CONCLUSIONS At equimolar doses, 1.0 M Gadobutrol demonstrates higher SNR/CNR than do Gadobenate dimeglumine and Gadoterate meglumine, with superior image quality as compared with Gadoterate meglumine for dynamic and static carotid MRA. Despite the shortened bolus with Gadobutrol, no blurring of vessel edges was observed.
Collapse
Affiliation(s)
- Jens Harald Kramer
- Institute for Clinical Radiology, Ludwig Maximilians University Hospital Munich, Munich, Germany.
| | | | | | | | | | | | | |
Collapse
|