Huang Z, Gunderman AL, Wilcox SE, Sengupta S, Shah J, Lu A, Woodrum D, Chen Y. Body-Mounted MR-Conditional Robot for Minimally Invasive Liver Intervention. Ann Biomed Eng 2024; 52:2065-2075. [PMID: 38634953 DOI: 10.1007/s10439-024-03503-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 03/25/2024] [Indexed: 04/19/2024]
Abstract
MR-guided microwave ablation (MWA) has proven effective in treating hepatocellular carcinoma (HCC) with small-sized tumors, but the state-of-the-art technique suffers from sub-optimal workflow due to the limited accuracy provided by the manual needle insertions. This paper presents a compact body-mounted MR-conditional robot that can operate in closed-bore MR scanners for accurate needle guidance. The robotic platform consists of two stacked Cartesian XY stages, each with two degrees of freedom, that facilitate needle insertion pose control. The robot is actuated using 3D-printed pneumatic turbines with MR-conditional bevel gear transmission systems. Pneumatic valves and control mechatronics are located inside the MRI control room and are connected to the robot with pneumatic transmission lines and optical fibers. Free-space experiments indicated robot-assisted needle insertion error of 2.6 ± 1.3 mm at an insertion depth of 80 mm. The MR-guided phantom studies were conducted to verify the MR-conditionality and targeting performance of the robot. Future work will focus on the system optimization and validations in animal trials.
Collapse
Affiliation(s)
- Zhefeng Huang
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA
| | - Anthony L Gunderman
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA
| | - Samuel E Wilcox
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA
| | - Saikat Sengupta
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, 1161 21st Ave South Medical Center North, Nashville, TN, 37232, USA
| | - Jay Shah
- Department of Radiology, Emory University, 1364 Clifton Rd, Atlanta, GA, 30329, USA
| | - Aiming Lu
- Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905, USA
| | - David Woodrum
- Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905, USA
| | - Yue Chen
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA.
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, 313 Ferst Dr, Atlanta, GA, 30332, USA.
| |
Collapse
|
2
|
Giannakou M, Antoniou A, Damianou C. Preclinical robotic device for magnetic resonance imaging guided focussed ultrasound. Int J Med Robot 2023; 19:e2466. [PMID: 36169287 PMCID: PMC10078206 DOI: 10.1002/rcs.2466] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 09/12/2022] [Accepted: 09/27/2022] [Indexed: 01/05/2023]
Abstract
BACKGROUND A robotic device featuring three motion axes was manufactured for preclinical research on focussed ultrasound (FUS). The device comprises a 2.75 MHz single element ultrasonic transducer and is guided by Magnetic Resonance Imaging (MRI). METHODS The compatibility of the device with the MRI was evaluated by estimating the influence on the signal-to-noise ratio (SNR). The efficacy of the transducer in generating ablative temperatures was evaluated in phantoms and excised porcine tissue. RESULTS System's activation in the MRI scanner reduced the SNR to an acceptable level without compromising the image quality. The transducer demonstrated efficient heating ability as proved by MR thermometry. Discrete and overlapping thermal lesions were inflicted in excised tissue. CONCLUSIONS The FUS system was proven effective for FUS thermal applications in the MRI setting. It can thus be used for multiple preclinical applications of the emerging MRI-guided FUS technology. The device can be scaled-up for human use with minor modifications.
Collapse
Affiliation(s)
| | - Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| |
Collapse
|
3
|
Lanza C, Carriero S, Buijs EFM, Mortellaro S, Pizzi C, Sciacqua LV, Biondetti P, Angileri SA, Ianniello AA, Ierardi AM, Carrafiello G. Robotics in Interventional Radiology: Review of Current and Future Applications. Technol Cancer Res Treat 2023; 22:15330338231152084. [PMID: 37113061 PMCID: PMC10150437 DOI: 10.1177/15330338231152084] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/29/2023] Open
Abstract
This review is a brief overview of the current status and the potential role of robotics in interventional radiology. Literature published in the last decades, with an emphasis on the last 5 years, was reviewed and the technical developments in robotics and navigational systems using CT-, MR- and US-image guidance were analyzed. Potential benefits and disadvantages of their current and future use were evaluated. The role of fusion imaging modalities and artificial intelligence was analyzed in both percutaneous and endovascular procedures. A few hundred articles describing results of single or several systems were included in our analysis.
Collapse
Affiliation(s)
- Carolina Lanza
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Milan, Italy
| | - Serena Carriero
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Milan, Italy
| | | | - Sveva Mortellaro
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Milan, Italy
| | - Caterina Pizzi
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Milan, Italy
| | | | - Pierpaolo Biondetti
- Foundation IRCCS Cà Granda-Ospedale Maggiore Policlinico, Milan, Italy
- Università degli Studi di Milano, Milan, Italy
| | | | | | | | - Gianpaolo Carrafiello
- Foundation IRCCS Cà Granda-Ospedale Maggiore Policlinico, Milan, Italy
- Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
4
|
Su H, Kwok KW, Cleary K, Iordachita I, Cavusoglu MC, Desai JP, Fischer GS. State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions. PROCEEDINGS OF THE IEEE. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS 2022; 110:968-992. [PMID: 35756185 PMCID: PMC9231642 DOI: 10.1109/jproc.2022.3169146] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of target anatomy, surrounding tissue, and instrumentation, but there are significant challenges in harnessing it for effectively guiding interventional procedures. Challenges include the strong static magnetic field, rapidly switching magnetic field gradients, high-power radio frequency pulses, sensitivity to electrical noise, and constrained space to operate within the bore of the scanner. MRI has a number of advantages over other medical imaging modalities, including no ionizing radiation, excellent soft-tissue contrast that allows for visualization of tumors and other features that are not readily visible by other modalities, true 3-D imaging capabilities, including the ability to image arbitrary scan plane geometry or perform volumetric imaging, and capability for multimodality sensing, including diffusion, dynamic contrast, blood flow, blood oxygenation, temperature, and tracking of biomarkers. The use of robotic assistants within the MRI bore, alongside the patient during imaging, enables intraoperative MR imaging (iMRI) to guide a surgical intervention in a closed-loop fashion that can include tracking of tissue deformation and target motion, localization of instrumentation, and monitoring of therapy delivery. With the ever-expanding clinical use of MRI, MRI-compatible robotic systems have been heralded as a new approach to assist interventional procedures to allow physicians to treat patients more accurately and effectively. Deploying robotic systems inside the bore synergizes the visual capability of MRI and the manipulation capability of robotic assistance, resulting in a closed-loop surgery architecture. This article details the challenges and history of robotic systems intended to operate in an MRI environment and outlines promising clinical applications and associated state-of-the-art MRI-compatible robotic systems and technology for making this possible.
Collapse
Affiliation(s)
- Hao Su
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA
| | - Ka-Wai Kwok
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong
| | - Kevin Cleary
- Children's National Health System, Washington, DC 20010 USA
| | - Iulian Iordachita
- Laboratory for Computational Sensing and Robotics (LCSR), Johns Hopkins University, Baltimore, MD 21218 USA
| | - M Cenk Cavusoglu
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH 44106 USA
| | - Jaydev P Desai
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| | - Gregory S Fischer
- Department of Robotics Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA
| |
Collapse
|
5
|
Fiorini P, Goldberg KY, Liu Y, Taylor RH. Concepts and Trends n Autonomy for Robot-Assisted Surgery. PROCEEDINGS OF THE IEEE. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS 2022; 110:993-1011. [PMID: 35911127 PMCID: PMC7613181 DOI: 10.1109/jproc.2022.3176828] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Surgical robots have been widely adopted with over 4000 robots being used in practice daily. However, these are telerobots that are fully controlled by skilled human surgeons. Introducing "surgeon-assist"-some forms of autonomy-has the potential to reduce tedium and increase consistency, analogous to driver-assist functions for lanekeeping, cruise control, and parking. This article examines the scientific and technical backgrounds of robotic autonomy in surgery and some ethical, social, and legal implications. We describe several autonomous surgical tasks that have been automated in laboratory settings, and research concepts and trends.
Collapse
Affiliation(s)
- Paolo Fiorini
- Department of Computer Science, University of Verona, 37134 Verona, Italy
| | - Ken Y. Goldberg
- Department of Industrial Engineering and Operations Research and the Department of Electrical Engineering and Computer Science, University of California at Berkeley, Berkeley, CA 94720 USA
| | - Yunhui Liu
- Department of Mechanical and Automation Engineering, T Stone Robotics Institute, The Chinese University of Hong Kong, Hong Kong, China
| | - Russell H. Taylor
- Department of Computer Science, the Department of Mechanical Engineering, the Department of Radiology, the Department of Surgery, and the Department of Otolaryngology, Head-and-Neck Surgery, Johns Hopkins University, Baltimore, MD 21218 USA, and also with the Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218 USA
| |
Collapse
|
6
|
Thompson SM, Gorny KR, Koepsel EMK, Welch BT, Mynderse L, Lu A, Favazza CP, Felmlee JP, Woodrum DA. Body Interventional MRI for Diagnostic and Interventional Radiologists: Current Practice and Future Prospects. Radiographics 2021; 41:1785-1801. [PMID: 34597216 DOI: 10.1148/rg.2021210040] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Clinical use of MRI for guidance during interventional procedures emerged shortly after the introduction of clinical diagnostic MRI in the late 1980s. However, early applications of interventional MRI (iMRI) were limited owing to the lack of dedicated iMRI magnets, pulse sequences, and equipment. During the 3 decades that followed, technologic advancements in iMRI magnets that balance bore access and field strength, combined with the development of rapid MRI pulse sequences, surface coils, and commercially available MR-conditional devices, led to the rapid expansion of clinical iMRI applications, particularly in the field of body iMRI. iMRI offers several advantages, including superior soft-tissue resolution, ease of multiplanar imaging, lack of ionizing radiation, and capability to re-image the same section. Disadvantages include longer examination times, lack of MR-conditional equipment, less operator familiarity, and increased cost. Nonetheless, MRI guidance is particularly advantageous when the disease is best visualized with MRI and/or when superior soft-tissue contrast is needed for treatment monitoring. Safety in the iMRI environment is paramount and requires close collaboration among interventional radiologists, MR physicists, and all other iMRI team members. The implementation of risk-limiting measures for personnel and equipment in MR zones III and IV is key. Various commercially available MR-conditional needles, wires, and biopsy and ablation devices are now available throughout the world, depending on the local regulatory status. As such, there has been tremendous growth in the clinical applications of body iMRI, including localization of difficult lesions, biopsy, sclerotherapy, and cryoablation and thermal ablation of malignant and nonmalignant soft-tissue neoplasms. Online supplemental material is available for this article. ©RSNA, 2021.
Collapse
Affiliation(s)
- Scott M Thompson
- From the Department of Radiology (S.M.T., K.R.G., E.M.K.K., B.T.W., A.L., C.P.F., J.P.F., D.A.W.), Division of Vascular and Interventional Radiology (S.M.T.), and Department of Urology (L.M.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905
| | - Krzysztof R Gorny
- From the Department of Radiology (S.M.T., K.R.G., E.M.K.K., B.T.W., A.L., C.P.F., J.P.F., D.A.W.), Division of Vascular and Interventional Radiology (S.M.T.), and Department of Urology (L.M.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905
| | - Erica M Knavel Koepsel
- From the Department of Radiology (S.M.T., K.R.G., E.M.K.K., B.T.W., A.L., C.P.F., J.P.F., D.A.W.), Division of Vascular and Interventional Radiology (S.M.T.), and Department of Urology (L.M.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905
| | - Brian T Welch
- From the Department of Radiology (S.M.T., K.R.G., E.M.K.K., B.T.W., A.L., C.P.F., J.P.F., D.A.W.), Division of Vascular and Interventional Radiology (S.M.T.), and Department of Urology (L.M.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905
| | - Lance Mynderse
- From the Department of Radiology (S.M.T., K.R.G., E.M.K.K., B.T.W., A.L., C.P.F., J.P.F., D.A.W.), Division of Vascular and Interventional Radiology (S.M.T.), and Department of Urology (L.M.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905
| | - Aiming Lu
- From the Department of Radiology (S.M.T., K.R.G., E.M.K.K., B.T.W., A.L., C.P.F., J.P.F., D.A.W.), Division of Vascular and Interventional Radiology (S.M.T.), and Department of Urology (L.M.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905
| | - Christopher P Favazza
- From the Department of Radiology (S.M.T., K.R.G., E.M.K.K., B.T.W., A.L., C.P.F., J.P.F., D.A.W.), Division of Vascular and Interventional Radiology (S.M.T.), and Department of Urology (L.M.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905
| | - Joel P Felmlee
- From the Department of Radiology (S.M.T., K.R.G., E.M.K.K., B.T.W., A.L., C.P.F., J.P.F., D.A.W.), Division of Vascular and Interventional Radiology (S.M.T.), and Department of Urology (L.M.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905
| | - David A Woodrum
- From the Department of Radiology (S.M.T., K.R.G., E.M.K.K., B.T.W., A.L., C.P.F., J.P.F., D.A.W.), Division of Vascular and Interventional Radiology (S.M.T.), and Department of Urology (L.M.), Mayo Clinic, 200 1st St SW, Rochester, MN 55905
| |
Collapse
|
7
|
Navaz AN, Serhani MA, El Kassabi HT, Al-Qirim N, Ismail H. Trends, Technologies, and Key Challenges in Smart and Connected Healthcare. IEEE ACCESS : PRACTICAL INNOVATIONS, OPEN SOLUTIONS 2021; 9:74044-74067. [PMID: 34812394 PMCID: PMC8545204 DOI: 10.1109/access.2021.3079217] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 05/05/2021] [Indexed: 05/04/2023]
Abstract
Cardio Vascular Diseases (CVD) is the leading cause of death globally and is increasing at an alarming rate, according to the American Heart Association's Heart Attack and Stroke Statistics-2021. This increase has been further exacerbated because of the current coronavirus (COVID-19) pandemic, thereby increasing the pressure on existing healthcare resources. Smart and Connected Health (SCH) is a viable solution for the prevalent healthcare challenges. It can reshape the course of healthcare to be more strategic, preventive, and custom-designed, making it more effective with value-added services. This research endeavors to classify state-of-the-art SCH technologies via a thorough literature review and analysis to comprehensively define SCH features and identify the enabling technology-related challenges in SCH adoption. We also propose an architectural model that captures the technological aspect of the SCH solution, its environment, and its primary involved stakeholders. It serves as a reference model for SCH acceptance and implementation. We reflected the COVID-19 case study illustrating how some countries have tackled the pandemic differently in terms of leveraging the power of different SCH technologies, such as big data, cloud computing, Internet of Things, artificial intelligence, robotics, blockchain, and mobile applications. In combating the pandemic, SCH has been used efficiently at different stages such as disease diagnosis, virus detection, individual monitoring, tracking, controlling, and resource allocation. Furthermore, this review highlights the challenges to SCH acceptance, as well as the potential research directions for better patient-centric healthcare.
Collapse
Affiliation(s)
- Alramzana Nujum Navaz
- Department of Information Systems and SecurityCollege of Information TechnologyUnited Arab Emirates UniversityAl AinUnited Arab Emirates
| | - Mohamed Adel Serhani
- Department of Information Systems and SecurityCollege of Information TechnologyUnited Arab Emirates UniversityAl AinUnited Arab Emirates
| | - Hadeel T. El Kassabi
- Department of Computer Science and Software EngineeringCollege of Information TechnologyUAE UniversityAl AinUnited Arab Emirates
| | - Nabeel Al-Qirim
- Department of Information Systems and SecurityCollege of Information TechnologyUnited Arab Emirates UniversityAl AinUnited Arab Emirates
| | - Heba Ismail
- Department of Computer Science and Information Technology (CS-IT)College of EngineeringAbu Dhabi UniversityAl AinUnited Arab Emirates
| |
Collapse
|
8
|
Mutlu S, Yasa O, Erin O, Sitti M. Magnetic Resonance Imaging-Compatible Optically Powered Miniature Wireless Modular Lorentz Force Actuators. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:2002948. [PMID: 33511017 PMCID: PMC7816712 DOI: 10.1002/advs.202002948] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 09/24/2020] [Indexed: 06/12/2023]
Abstract
Minimally invasive medical procedures under magnetic resonance imaging (MRI) guidance have significant clinical promise. However, this potential has not been fully realized yet due to challenges regarding MRI compatibility and miniaturization of active and precise positioning systems inside MRI scanners, i.e., restrictions on ferromagnetic materials and long conductive cables and limited space around the patient for additional instrumentation. Lorentz force-based electromagnetic actuators can overcome these challenges with the help of very high, axial, and uniform magnetic fields (3-7 Tesla) of the scanners. Here, a miniature, MRI-compatible, and optically powered wireless Lorentz force actuator module consisting of a solar cell and a coil with a small volume of 2.5 × 2.5 × 3.0 mm3 is proposed. Many of such actuator modules can be used to create various wireless active structures for future interventional MRI applications, such as positioning needles, markers, or other medical tools on the skin of a patient. As proof-of-concept prototypes toward such applications, a single actuator module that bends a flexible beam, four modules that rotate around an axis, and six modules that roll as a sphere are demonstrated inside a 7 Tesla preclinical MRI scanner.
Collapse
Affiliation(s)
- Senol Mutlu
- Physical Intelligence DepartmentMax Planck Institute for Intelligent SystemsStuttgart70569Germany
- Department of Electrical and Electronics EngineeringBogazici UniversityIstanbul34342Turkey
| | - Oncay Yasa
- Physical Intelligence DepartmentMax Planck Institute for Intelligent SystemsStuttgart70569Germany
| | - Onder Erin
- Physical Intelligence DepartmentMax Planck Institute for Intelligent SystemsStuttgart70569Germany
- Carnegie Mellon UniversityMechanical Engineering DepartmentPittsburghPA15213USA
| | - Metin Sitti
- Physical Intelligence DepartmentMax Planck Institute for Intelligent SystemsStuttgart70569Germany
- School of Medicine and School of EngineeringKoc UniversityIstanbul34450Turkey
- Institute for Biomedical EngineeringETH ZurichZurich8092Switzerland
| |
Collapse
|
9
|
AI applications in robotics, diagnostic image analysis and precision medicine: Current limitations, future trends, guidelines on CAD systems for medicine. INFORMATICS IN MEDICINE UNLOCKED 2021. [DOI: 10.1016/j.imu.2021.100596] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
|
10
|
MR Imaging Safety in the Interventional Environment. Magn Reson Imaging Clin N Am 2020; 28:583-591. [PMID: 33040998 DOI: 10.1016/j.mric.2020.07.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Interventional MR imaging procedures are rapidly growing in number owing to the excellent soft tissue resolution of MR imaging, lack of ionizing radiation, hardware and software advancements, and technical developments in MR imaging-compatible robots, lasers, and ultrasound equipment. The safe operation of an interventional MR imaging system is a complex undertaking, which is only possible with multidisciplinary planning, training, operations and oversight. Safety for both patients and operators is essential for successful operations. Herein, we review the safety concerns, solutions and challenges associated with the operation of a modern interventional MR imaging system.
Collapse
|
11
|
Neumann W, Pusch TP, Siegfarth M, Schad LR, Stallkamp JL. CT and MRI compatibility of flexible 3D-printed materials for soft actuators and robots used in image-guided interventions. Med Phys 2019; 46:5488-5498. [PMID: 31587313 DOI: 10.1002/mp.13852] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 08/12/2019] [Accepted: 09/26/2019] [Indexed: 01/09/2023] Open
Abstract
PURPOSE Three-dimensional (3D) printing allows for the fabrication of medical devices with complex geometries, such as soft actuators and robots that can be used in image-guided interventions. This study investigates flexible and rigid 3D-printing materials in terms of their impact on multimodal medical imaging. METHODS The generation of artifacts in clinical computer tomography (CT) and magnetic resonance (MR) imaging was evaluated for six flexible and three rigid materials, each with a cubical and a cylindrical geometry, and for one exemplary flexible fluidic actuator. Additionally, CT Hounsfield units (HU) were quantified for various parameter sets iterating peak voltage, x-ray tube current, slice thickness, and convolution kernel. RESULTS We found the image artifacts caused by the materials to be negligible in both CT and MR images. The HU values mainly depended on the elemental composition of the materials and applied peak voltage was ranging between 80 and 140 kVp. Flexible, nonsilicone-based materials were ranged between 51 and 114 HU. The voltage dependency was less than 29 HU. Flexible, silicone-based materials were ranged between 60 and 365 HU. The voltage-dependent influence was as large as 172 HU. Rigid materials ranged between -69 and 132 HU. The voltage-dependent influence was <33 HU. CONCLUSIONS All tested materials may be employed for devices placed in the field of view during CT and MR imaging as no significant artifacts were measured. Moreover, the material selection in CT could be based on the desired visibility of the material depending on the application. Given the wide availability of the tested materials, we expect our results to have a positive impact on the development of devices and robots for image-guided interventions.
Collapse
Affiliation(s)
- Wiebke Neumann
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany
| | - Tim P Pusch
- Fraunhofer Institute for Manufacturing Engineering and Automation, Project Group for Automation in Medicine and Biotechnology, 68167, Mannheim, Germany
| | - Marius Siegfarth
- Fraunhofer Institute for Manufacturing Engineering and Automation, Project Group for Automation in Medicine and Biotechnology, 68167, Mannheim, Germany
| | - Lothar R Schad
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany
| | - Jan L Stallkamp
- Fraunhofer Institute for Manufacturing Engineering and Automation, Project Group for Automation in Medicine and Biotechnology, 68167, Mannheim, Germany.,Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany
| |
Collapse
|
12
|
|
13
|
Weiss CR, Fritz J. The State-of-the-Art of Interventional Magnetic Resonance Imaging: Part 2. Top Magn Reson Imaging 2018; 27:113-114. [PMID: 29870463 DOI: 10.1097/rmr.0000000000000171] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Affiliation(s)
- Clifford R Weiss
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD
| | | |
Collapse
|
14
|
Fritz J, Weiss CR. The State-of-the-Art of Interventional Magnetic Resonance Imaging: Part 1. Top Magn Reson Imaging 2018; 27:1-2. [PMID: 29406407 DOI: 10.1097/rmr.0000000000000168] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Affiliation(s)
- Jan Fritz
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD
| | | |
Collapse
|