1
|
Ashcraft M, Garren M, Lautner-Csorba O, Pinon V, Wu Y, Crowley D, Hill J, Morales Y, Bartlett R, Brisbois EJ, Handa H. Surface Engineering for Endothelium-Mimicking Functions to Combat Infection and Thrombosis in Extracorporeal Life Support Technologies. Adv Healthc Mater 2024; 13:e2400492. [PMID: 38924661 PMCID: PMC11468007 DOI: 10.1002/adhm.202400492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 06/20/2024] [Indexed: 06/28/2024]
Abstract
Blood-contacting medical devices routinely fail from the cascading effects of biofouling toward infection and thrombosis. Nitric oxide (NO) is an integral part of endothelial homeostasis, maintaining platelet quiescence and facilitating oxidative/nitrosative stress against pathogens. Recently, it is shown that the surface evolution of NO can mediate cell-surface interactions. However, this technique alone cannot prevent the biofouling inherent in device failure with dynamic blood-contacting applications. This work proposes an endothelium-mimicking surface design pairing controlled NO release with an inherently antifouling polyethylene glycol interface (NO+PEG). This simple, robust, and scalable platform develops surface-localized NO availability with surface hydration, leading to a significant reduction in protein adsorption as well as bacteria/platelet adhesion. Further in vivo thrombogenicity studies show a decrease in thrombus formation on NO+PEG interfaces, with preservation of circulating platelet and white blood cell counts, maintenance of activated clotting time, and reduced coagulation cascade activation. It is anticipated that this bio-inspired surface design will enable a facile alternative to existing surface technologies to address clinical manifestations of infection and thrombosis in dynamic blood-contacting environments.
Collapse
Affiliation(s)
- Morgan Ashcraft
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia 30602, United States
| | - Mark Garren
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States
| | - Orsolya Lautner-Csorba
- Department of Surgery, University of Michigan Medical Center, Ann Arbor, Michigan 48109, United States
| | - Vicente Pinon
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia 30602, United States
| | - Yi Wu
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States
| | - Dagney Crowley
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States
| | - Joseph Hill
- Department of Surgery, University of Michigan Medical Center, Ann Arbor, Michigan 48109, United States
| | - Yeniselis Morales
- Department of Surgery, University of Michigan Medical Center, Ann Arbor, Michigan 48109, United States
| | - Robert Bartlett
- Department of Surgery, University of Michigan Medical Center, Ann Arbor, Michigan 48109, United States
| | - Elizabeth J. Brisbois
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States
| | - Hitesh Handa
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia 30602, United States
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States
| |
Collapse
|
2
|
Abedi F, Zarei B, Elyasi S. Albumin: a comprehensive review and practical guideline for clinical use. Eur J Clin Pharmacol 2024; 80:1151-1169. [PMID: 38607390 DOI: 10.1007/s00228-024-03664-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 03/04/2024] [Indexed: 04/13/2024]
Abstract
PURPOSE Nowadays, it is largely accepted that albumin should not be used in hypoalbuminemia or for nutritional purpose. The most discussed indication of albumin at present is the resuscitation in shock states, especially distributive shocks such as septic shock. The main evidence-based indication is also liver disease. In this review, we provided updated evidence-based instruction for definite and potential indications of albumin administration in clinical practice, with appropriate dosing and duration. METHODS Data collection was carried out until November 2023 by search of electronic databases including PubMed, Google Scholar, Scopus, and Web of Science. GRADE system has been used to determine the quality of evidence and strength of recommendations for each albumin indication. RESULTS A total of 165 relevant studies were included in this review. Fluid replacement in plasmapheresis and liver diseases, including hepatorenal syndrome, spontaneous bacterial peritonitis, and large-volume paracentesis, have a moderate to high quality of evidence and a strong recommendation for administering albumin. Moreover, albumin is used as a second-line and adjunctive to crystalloids for fluid resuscitation in hypovolemic shock, sepsis and septic shock, severe burns, toxic epidermal necrolysis, intradialytic hypotension, ovarian hyperstimulation syndrome, major surgery, non-traumatic brain injury, extracorporeal membrane oxygenation, acute respiratory distress syndrome, and severe and refractory edema with hypoalbuminemia has a low to moderate quality of evidence and weak recommendation to use. Also, in modest volume paracentesis, severe hyponatremia in cirrhosis has a low to moderate quality of evidence and a weak recommendation. CONCLUSION Albumin administration is most indicated in management of cirrhosis complications. Fluid resuscitation or treatment of severe and refractory edema, especially in patients with hypoalbuminemia and not responding to other treatments, is another rational use for albumin. Implementation of evidence-based guidelines in hospitals can be an effective measure to reduce inappropriate uses of albumin.
Collapse
Affiliation(s)
- Farshad Abedi
- Department of Clinical Pharmacy, School of Pharmacy, Mashhad University of Medical Sciences, P.O. Box, Mashhad, 91775-1365, Iran
| | - Batool Zarei
- Department of Clinical Pharmacy, School of Pharmacy, Mashhad University of Medical Sciences, P.O. Box, Mashhad, 91775-1365, Iran.
| | - Sepideh Elyasi
- Department of Clinical Pharmacy, School of Pharmacy, Mashhad University of Medical Sciences, P.O. Box, Mashhad, 91775-1365, Iran.
| |
Collapse
|
3
|
Roberts TR, Persello A, Harea GT, Vedula EM, Isenberg BC, Zang Y, Santos J, Borenstein JT, Batchinsky AI. First 24-Hour-Long Intensive Care Unit Testing of a Clinical-Scale Microfluidic Oxygenator in Swine: A Safety and Feasibility Study. ASAIO J 2024; 70:535-544. [PMID: 38165978 DOI: 10.1097/mat.0000000000002127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2024] Open
Abstract
Microfluidic membrane oxygenators are designed to mimic branching vasculature of the native lung during extracorporeal lung support. To date, scaling of such devices to achieve clinically relevant blood flow and lung support has been a limitation. We evaluated a novel multilayer microfluidic blood oxygenator (BLOx) capable of supporting 750-800 ml/min blood flow versus a standard hollow fiber membrane oxygenator (HFMO) in vivo during veno-venous extracorporeal life support for 24 hours in anesthetized, mechanically ventilated uninjured swine (n = 3/group). The objective was to assess feasibility, safety, and biocompatibility. Circuits remained patent and operated with stable pressures throughout 24 hours. No group differences in vital signs or evidence of end-organ damage occurred. No change in plasma free hemoglobin and von Willebrand factor multimer size distribution were observed. Platelet count decreased in BLOx at 6 hours (37% dec, P = 0.03), but not in HFMO; however, thrombin generation potential was elevated in HFMO (596 ± 81 nM·min) versus BLOx (323 ± 39 nM·min) at 24 hours ( P = 0.04). Other coagulation and inflammatory mediator results were unremarkable. BLOx required higher mechanical ventilator settings and showed lower gas transfer efficiency versus HFMO, but the stable device performance indicates that this technology is ready for further performance scaling and testing in lung injury models and during longer use conditions.
Collapse
Affiliation(s)
- Teryn R Roberts
- From the Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas
| | - Antoine Persello
- From the Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas
| | - George T Harea
- From the Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas
| | - Else M Vedula
- Bioengineering Division, Draper, Cambridge, Massachusetts
| | | | - Yanyi Zang
- From the Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas
| | - Jose Santos
- Bioengineering Division, Draper, Cambridge, Massachusetts
| | | | - Andriy I Batchinsky
- From the Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas
| |
Collapse
|
4
|
Zawidlak-Węgrzyńska B, Rydz J, Musioł M, Radziwon-Balicka A. Polymer-Drug Anti-Thrombogenic and Hemocompatible Coatings as Surface Modifications. Pharmaceutics 2024; 16:432. [PMID: 38543326 PMCID: PMC10974185 DOI: 10.3390/pharmaceutics16030432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 03/14/2024] [Accepted: 03/18/2024] [Indexed: 11/12/2024] Open
Abstract
Since the 1960s, efforts have been made to develop new technologies to eliminate the risk of thrombosis in medical devices that come into contact with blood. Preventing thrombosis resulting from the contact of a medical device, such as an implant, with blood is a challenge due to the high mortality rate of patients and the high cost of medical care. To this end, various types of biomaterials coated with polymer-drug layers are being designed to reduce their thrombogenicity and improve their hemocompatibility. This review presents the latest developments in the use of polymer-drug systems to produce anti-thrombogenic surfaces in medical devices in contact with blood, such as stents, catheters, blood pumps, heart valves, artificial lungs, blood vessels, blood oxygenators, and various types of tubing (such as for hemodialysis) as well as microfluidic devices. This paper presents research directions and potential clinical applications, emphasizing the importance of continued progress and innovation in the field.
Collapse
Affiliation(s)
- Barbara Zawidlak-Węgrzyńska
- Department of Chemistry, Faculty of Medicine in Zabrze, Academy of Silesia in Katowice, 40-555 Katowice, Poland
| | - Joanna Rydz
- Centre of Polymer and Carbon Materials, Polish Academy of Sciences, 41-819 Zabrze, Poland; (J.R.); (M.M.)
| | - Marta Musioł
- Centre of Polymer and Carbon Materials, Polish Academy of Sciences, 41-819 Zabrze, Poland; (J.R.); (M.M.)
| | - Aneta Radziwon-Balicka
- Department of Respiratory and Infectious Diseases, Center for Translational Research, Bispebjerg Hospital, University of Copenhagen, 1172 København, Denmark;
| |
Collapse
|
5
|
Geetha S, Verma N, Chakole V. A Comprehensive Review of Extra Corporeal Membrane Oxygenation: The Lifeline in Critical Moments. Cureus 2024; 16:e53275. [PMID: 38435953 PMCID: PMC10905309 DOI: 10.7759/cureus.53275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Accepted: 01/31/2024] [Indexed: 03/05/2024] Open
Abstract
Extracorporeal membrane oxygenation (ECMO) has evolved into a pivotal intervention in critical care, offering a lifeline for patients facing severe respiratory or cardiac failure. This review provides a comprehensive exploration of ECMO, spanning its definition and historical background to its contemporary advancements and ongoing impact in critical care. The versatility of ECMO in addressing diverse critical conditions, careful patient selection criteria, and the nuanced management of complications are discussed. Advances in technology, including miniaturization, novel circuit designs, and the integration of remote monitoring, showcase the evolving landscape of ECMO. The review underscores the ongoing impact of ECMO in improving survival rates, enhancing mobility, and enabling remote expertise. As a symbol of hope and innovation, ECMO's lifesaving potential is evident in its ability to navigate the complexities of critical care and redefine the boundaries of life support interventions.
Collapse
Affiliation(s)
- Sindhu Geetha
- Anaesthesiology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Neeta Verma
- Anaesthesiology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Vivek Chakole
- Anaesthesiology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| |
Collapse
|
6
|
Tonetti T, Zanella A, Pérez-Torres D, Grasselli G, Ranieri VM. Current knowledge gaps in extracorporeal respiratory support. Intensive Care Med Exp 2023; 11:77. [PMID: 37962702 PMCID: PMC10645840 DOI: 10.1186/s40635-023-00563-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 11/08/2023] [Indexed: 11/15/2023] Open
Abstract
Extracorporeal life support (ECLS) for acute respiratory failure encompasses veno-venous extracorporeal membrane oxygenation (V-V ECMO) and extracorporeal carbon dioxide removal (ECCO2R). V-V ECMO is primarily used to treat severe acute respiratory distress syndrome (ARDS), characterized by life-threatening hypoxemia or ventilatory insufficiency with conventional protective settings. It employs an artificial lung with high blood flows, and allows improvement in gas exchange, correction of hypoxemia, and reduction of the workload on the native lung. On the other hand, ECCO2R focuses on carbon dioxide removal and ventilatory load reduction ("ultra-protective ventilation") in moderate ARDS, or in avoiding pump failure in acute exacerbated chronic obstructive pulmonary disease. Clinical indications for V-V ECLS are tailored to individual patients, as there are no absolute contraindications. However, determining the ideal timing for initiating extracorporeal respiratory support remains uncertain. Current ECLS equipment faces issues like size and durability. Innovations include intravascular lung assist devices (ILADs) and pumpless devices, though they come with their own challenges. Efficient gas exchange relies on modern oxygenators using hollow fiber designs, but research is exploring microfluidic technology to improve oxygenator size, thrombogenicity, and blood flow capacity. Coagulation management during V-V ECLS is crucial due to common bleeding and thrombosis complications; indeed, anticoagulation strategies and monitoring systems require improvement, while surface coatings and new materials show promise. Moreover, pharmacokinetics during ECLS significantly impact antibiotic therapy, necessitating therapeutic drug monitoring for precise dosing. Managing native lung ventilation during V-V ECMO remains complex, requiring a careful balance between benefits and potential risks for spontaneously breathing patients. Moreover, weaning from V-V ECMO is recognized as an area of relevant uncertainty, requiring further research. In the last decade, the concept of Extracorporeal Organ Support (ECOS) for patients with multiple organ dysfunction has emerged, combining ECLS with other organ support therapies to provide a more holistic approach for critically ill patients. In this review, we aim at providing an in-depth overview of V-V ECMO and ECCO2R, addressing various aspects of their use, challenges, and potential future directions in research and development.
Collapse
Affiliation(s)
- Tommaso Tonetti
- Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum-University of Bologna, Bologna, Italy
- Anesthesiology and General Intensive Care Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico di S.Orsola, Bologna, Italy
| | - Alberto Zanella
- Department of Anesthesia, Critical Care and Emergency, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Ca' Granda Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - David Pérez-Torres
- Servicio de Medicina Intensiva, Hospital Universitario Río Hortega, Gerencia Regional de Salud de Castilla y León (SACYL), Calle Dulzaina, 2, 47012, Valladolid, Spain
| | - Giacomo Grasselli
- Department of Anesthesia, Critical Care and Emergency, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Ca' Granda Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy.
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
| | - V Marco Ranieri
- Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum-University of Bologna, Bologna, Italy
- Anesthesiology and General Intensive Care Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico di S.Orsola, Bologna, Italy
| |
Collapse
|
7
|
Zang Y, Roberts TR, Harea GT, Beely BM, Perez LOJ, Ande S, Batchinsky M, Lee JH, Thrailkill MA, Reynolds MM, Batchinsky AI. Quantitative Analysis of Clot Deposition on Extracorporeal Life Support Membrane Oxygenators Using Digital and Scanning Electron Microscopy Imaging Techniques. Bio Protoc 2023; 13:e4814. [PMID: 37753473 PMCID: PMC10518701 DOI: 10.21769/bioprotoc.4814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 06/16/2023] [Accepted: 06/27/2023] [Indexed: 09/28/2023] Open
Abstract
Device-induced thrombosis remains a major complication of extracorporeal life support (ECLS). To more thoroughly understand how blood components interact with the artificial surfaces of ECLS circuit components, assessment of clot deposition on these surfaces following clinical use is urgently needed. Scanning electron microscopy (SEM), which produces high-resolution images at nanoscale level, allows visualization and characterization of thrombotic deposits on ECLS circuitry. However, methodologies to increase the quantifiability of SEM analysis of ECLS circuit components have yet to be applied clinically. To address these issues, we developed a protocol to quantify clot deposition on ECLS membrane oxygenator gas transfer fiber sheets through digital and SEM imaging techniques. In this study, ECLS membrane oxygenator fiber sheets were obtained, fixed, and imaged after use. Following a standardized process, the percentage of clot deposition on both digital images and SEM images was quantified using ImageJ through blind reviews. The interrater reliability of quantitative analysis among reviewers was evaluated. Although this protocol focused on the analysis of ECLS membrane oxygenators, it is also adaptable to other components of the ECLS circuits such as catheters and tubing. Key features • Quantitative analysis of clot deposition using digital and scanning electron microscopy (SEM) techniques • High-resolution images at nanoscale level • Extracorporeal life support (ECLS) devices • Membrane oxygenators • Blood-contacting surfaces Graphical overview.
Collapse
Affiliation(s)
- Yanyi Zang
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, TX, USA
- Department of Translational Medicine, University of the Incarnate Word School of Osteopathic Medicine, San Antonio, TX, USA
| | - Teryn R. Roberts
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, TX, USA
- Department of Translational Medicine, University of the Incarnate Word School of Osteopathic Medicine, San Antonio, TX, USA
| | - George T. Harea
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, TX, USA
- Department of Translational Medicine, University of the Incarnate Word School of Osteopathic Medicine, San Antonio, TX, USA
| | - Brendan M. Beely
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, TX, USA
- Department of Translational Medicine, University of the Incarnate Word School of Osteopathic Medicine, San Antonio, TX, USA
| | | | - Sreedevi Ande
- School of Mathematics, Science and Engineering, University of the Incarnate Word, San Antonio, TX, USA
| | - Maria Batchinsky
- Texas Tech University Health Sciences Center School of Medicine, Lubbock, TX, USA
| | - Ji H. Lee
- Alaka’ina Foundation Family of Companies, Honolulu, HI, USA
| | - Marianne A. Thrailkill
- McGovern Medical School at The University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Melissa M. Reynolds
- Department of Chemistry and School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Andriy I. Batchinsky
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, TX, USA
- Department of Translational Medicine, University of the Incarnate Word School of Osteopathic Medicine, San Antonio, TX, USA
| |
Collapse
|
8
|
Isenberg BC, Vedula EM, Santos J, Lewis DJ, Roberts TR, Harea G, Sutherland D, Landis B, Blumenstiel S, Urban J, Lang D, Teece B, Lai W, Keating R, Chiang D, Batchinsky AI, Borenstein JT. A Clinical-Scale Microfluidic Respiratory Assist Device with 3D Branching Vascular Networks. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2207455. [PMID: 37092588 PMCID: PMC10288269 DOI: 10.1002/advs.202207455] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 03/10/2023] [Indexed: 05/03/2023]
Abstract
Recent global events such as COVID-19 pandemic amid rising rates of chronic lung diseases highlight the need for safer, simpler, and more available treatments for respiratory failure, with increasing interest in extracorporeal membrane oxygenation (ECMO). A key factor limiting use of this technology is the complexity of the blood circuit, resulting in clotting and bleeding and necessitating treatment in specialized care centers. Microfluidic oxygenators represent a promising potential solution, but have not reached the scale or performance required for comparison with conventional hollow fiber membrane oxygenators (HFMOs). Here the development and demonstration of the first microfluidic respiratory assist device at a clinical scale is reported, demonstrating efficient oxygen transfer at blood flow rates of 750 mL min⁻1 , the highest ever reported for a microfluidic device. The central innovation of this technology is a fully 3D branching network of blood channels mimicking key features of the physiological microcirculation by avoiding anomalous blood flows that lead to thrombus formation and blood damage in conventional oxygenators. Low, stable blood pressure drop, low hemolysis, and consistent oxygen transfer, in 24-hour pilot large animal experiments are demonstrated - a key step toward translation of this technology to the clinic for treatment of a range of lung diseases.
Collapse
Affiliation(s)
| | | | - Jose Santos
- Bioengineering DivisionDraperCambridgeMA02139USA
| | | | - Teryn R. Roberts
- Autonomous Reanimation and Evacuation (AREVA) Research ProgramThe Geneva FoundationSan AntonioTX78234USA
| | - George Harea
- Autonomous Reanimation and Evacuation (AREVA) Research ProgramThe Geneva FoundationSan AntonioTX78234USA
| | | | - Beau Landis
- Bioengineering DivisionDraperCambridgeMA02139USA
| | | | - Joseph Urban
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Daniel Lang
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Bryan Teece
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - WeiXuan Lai
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Rose Keating
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Diana Chiang
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Andriy I. Batchinsky
- Autonomous Reanimation and Evacuation (AREVA) Research ProgramThe Geneva FoundationSan AntonioTX78234USA
| | | |
Collapse
|
9
|
Wick TV, Roberts TR, Batchinsky AI, Tuttle RR, Reynolds MM. Surface Modification of Oxygenator Fibers with a Catalytically Active Metal-Organic Framework to Generate Nitric Oxide: An Ex Vivo Pilot Study. ACS APPLIED BIO MATERIALS 2023; 6:1953-1959. [PMID: 37068205 DOI: 10.1021/acsabm.3c00154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2023]
Abstract
Coating all portions of an extracorporeal membrane oxygenation (ECMO) circuit with materials exhibiting inherent, permanent antithrombotic properties is an essential step to prevent thrombus-induced complications. However, developing antithrombotic coatings for oxygenator fibers within membrane oxygenators of ECMO systems has proven challenging. We have used polydopamine (PDA) to coat oxygenator fibers and immobilize a Cu-based metal-organic framework (MOF) on the surface to act as a nitric oxide (NO) catalyst. Importantly, the PDA/MOF coating will produce NO indefinitely from endogenous S-nitrosothiols and it has not previously been applied to ECMO oxygenator fibers.
Collapse
Affiliation(s)
- Tracey V Wick
- Colorado State University, 301 W. Pitkin, Chemistry Research Building, Fort Collins, Colorado 80521, United States
| | - Teryn R Roberts
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, 2509 Kennedy Circle Building 125, 2nd Floor, San Antonio, Texas 78235, United States
| | - Andriy I Batchinsky
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, 2509 Kennedy Circle Building 125, 2nd Floor, San Antonio, Texas 78235, United States
| | - Robert R Tuttle
- Colorado State University, 301 W. Pitkin, Chemistry Research Building, Fort Collins, Colorado 80521, United States
| | - Melissa M Reynolds
- Colorado State University, 301 W. Pitkin, Chemistry Research Building, Fort Collins, Colorado 80521, United States
| |
Collapse
|
10
|
Roberts TR, Harea GT, Zang Y, Devine RP, Maffe P, Handa H, Batchinsky AI. A dual-action nitric oxide-releasing slippery surface for extracorporeal organ support: Dynamic in vitro hemocompatibility evaluation. J Biomed Mater Res B Appl Biomater 2023; 111:923-932. [PMID: 36404401 DOI: 10.1002/jbm.b.35202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 11/01/2022] [Accepted: 11/13/2022] [Indexed: 11/22/2022]
Abstract
Numerous biomaterials have been developed for application in blood-contacting medical devices to prevent thrombosis; however, few materials have been applied to full-scale devices and evaluated for hemocompatibility under clinical blood flow conditions. We applied a dual-action slippery liquid-infused (LI) nitric oxide (NO)-releasing material modification (LINO) to full-scale blood circulation tubing for extracorporeal lung support and evaluated the tubing ex vivo using swine whole blood circulated for 6 h at a clinically relevant flow. LINO tubing was compared to unmodified tubing (CTRL) and isolated LI and NO-releasing modifications (n = 9/group). The primary objective was to evaluate safety and blood compatibility of this approach, prior to progression to in vivo testing of efficacy in animal models. The secondary objective was to evaluate coagulation outcomes relevant to hemocompatibility. No untoward effects of the coating, such as elevated methemoglobin fraction, were observed. Additionally, LINO delayed platelet loss until 6 h versus the reduction in platelet count in CTRL at 3 h. At 6 h, LINO significantly reduced the concentration of platelets in an activated P-selectin expressing state versus CTRL (32 ± 1% decrease, p = .02). Blood clot deposition was significantly reduced on LINO blood pumps (p = .007) and numerically reduced on tubing versus CTRL. Following blood exposure, LINO tubing continued to produce a measurable NO-flux (0.20 ± 0.06 × 10-10 mol cm-2 min-1 ). LINO is a potential solution to reduce circuit-related bleeding and clotting during extracorporeal organ support, pending future extended testing in vivo using full-scale extracorporeal lung support devices.
Collapse
Affiliation(s)
- Teryn R Roberts
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas, USA
| | - George T Harea
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas, USA
| | - Yanyi Zang
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas, USA
| | - Ryan P Devine
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia, USA
| | - Patrick Maffe
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia, USA
| | - Hitesh Handa
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia, USA.,Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia, USA
| | - Andriy I Batchinsky
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas, USA
| |
Collapse
|
11
|
Spiegelburg DT, Mannes M, Schultze A, Scheibenberger F, Müller F, Klitzing A, Messerer DAC, Nilsson Ekdahl K, Nilsson B, Huber-Lang M, Braun CK. Impact of surface coating and systemic anticoagulants on hemostasis and inflammation in a human whole blood model. PLoS One 2023; 18:e0280069. [PMID: 36634087 PMCID: PMC9836312 DOI: 10.1371/journal.pone.0280069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 12/20/2022] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND Surface compatibility with blood is critical both for scientific investigations on hemostasis and clinical applications. Regarding in vitro and ex vivo investigations, minimal alteration in physiological hemostasis is of particular importance to draw reliable conclusions on the human coagulation system. At the same time, artificial coagulation activation must be avoided, which is relevant for the patient, for example to prevent stent graft occlusion. The aim was to evaluate the advantages and disadvantages of antithrombotic and antifouling surface coatings in the context of their suitability for ex vivo incubation and the study of coagulation properties. METHODS We investigated the impact of different protocols for surface coating of synthetic material and different anticoagulants on hemostasis and platelet activation in ex vivo human whole blood. Blood samples from healthy donors were incubated in coated microtubes on a rotating wheel at 37°C. Two protocols for surface coating were analyzed for hemostatic parameters and metabolic status, a heparin-based coating (CHC, Corline Heparin Conjugate) without further anticoagulation and a passivating coating (MPC, 2-methacryloyloxethyl phosphorylcholine) with added anticoagulants (enoxaparin, ENOX; or fondaparinux, FPX). Employing the MPC-based coating, the anticoagulants enoxaparin and fondaparinux were compared regarding their differential effects on plasmatic coagulation by thrombelastometry and on platelet activation by flowcytometry and platelet function assays. RESULTS Using the CHC coating, significant coagulation cascade activation was observed, whereas parameters remained mostly unchanged with MPC-based protocols. Extended incubation caused significantly elevated levels of the soluble membrane attack complex. Neither ENOX nor FPX caused a relevant impairment of platelet function or activation capacity and thrombelastometric parameters remained unchanged with both protocols. For translational purposes, we additionally modeled endotoxemia with the MPC-based protocols by incubating with lipopolysaccharide plus/minus thrombin. While coagulation parameters remained unchanged, elevated Interleukin 8 and Matrix Metalloproteinase 9 demonstrated preserved immune cell responsiveness. CONCLUSIONS The MPC-based protocols demonstrated better hemocompatibility compared to CHC, and ENOX and FPX proved useful for additional anticoagulation. Furthermore, this simple-to-use whole blood model may be useful for experimental analyses of the early coagulatory and immunological response without decalcification.
Collapse
Affiliation(s)
- Doreen Tabea Spiegelburg
- Institute for Clinical and Experimental Trauma Immunology, University Hospital of Ulm, Ulm, Germany
| | - Marco Mannes
- Institute for Clinical and Experimental Trauma Immunology, University Hospital of Ulm, Ulm, Germany
| | - Anke Schultze
- Institute for Clinical and Experimental Trauma Immunology, University Hospital of Ulm, Ulm, Germany
| | - Frieder Scheibenberger
- Institute for Clinical and Experimental Trauma Immunology, University Hospital of Ulm, Ulm, Germany
| | - Frederik Müller
- Institute for Clinical and Experimental Trauma Immunology, University Hospital of Ulm, Ulm, Germany
| | - Amadeo Klitzing
- Institute for Clinical and Experimental Trauma Immunology, University Hospital of Ulm, Ulm, Germany
| | - David Alexander Christian Messerer
- Institute for Clinical and Experimental Trauma Immunology, University Hospital of Ulm, Ulm, Germany
- Department of Transfusion Medicine and Hemostaseology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Kristina Nilsson Ekdahl
- Centre of Biomaterials Chemistry, Linnaeus University, Kalmar, Sweden
- Rudbeck Laboratory, Department of Immunology, Genetics and Pathology, Uppsala, Sweden
| | - Bo Nilsson
- Rudbeck Laboratory, Department of Immunology, Genetics and Pathology, Uppsala, Sweden
| | - Markus Huber-Lang
- Institute for Clinical and Experimental Trauma Immunology, University Hospital of Ulm, Ulm, Germany
| | - Christian Karl Braun
- Institute for Clinical and Experimental Trauma Immunology, University Hospital of Ulm, Ulm, Germany
- * E-mail:
| |
Collapse
|
12
|
Douglass M, Garren M, Devine R, Mondal A, Handa H. Bio-inspired hemocompatible surface modifications for biomedical applications. PROGRESS IN MATERIALS SCIENCE 2022; 130:100997. [PMID: 36660552 PMCID: PMC9844968 DOI: 10.1016/j.pmatsci.2022.100997] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
When blood first encounters the artificial surface of a medical device, a complex series of biochemical reactions is triggered, potentially resulting in clinical complications such as embolism/occlusion, inflammation, or device failure. Preventing thrombus formation on the surface of blood-contacting devices is crucial for maintaining device functionality and patient safety. As the number of patients reliant on blood-contacting devices continues to grow, minimizing the risk associated with these devices is vital towards lowering healthcare-associated morbidity and mortality. The current standard clinical practice primarily requires the systemic administration of anticoagulants such as heparin, which can result in serious complications such as post-operative bleeding and heparin-induced thrombocytopenia (HIT). Due to these complications, the administration of antithrombotic agents remains one of the leading causes of clinical drug-related deaths. To reduce the side effects spurred by systemic anticoagulation, researchers have been inspired by the hemocompatibility exhibited by natural phenomena, and thus have begun developing medical-grade surfaces which aim to exhibit total hemocompatibility via biomimicry. This review paper aims to address different bio-inspired surface modifications that increase hemocompatibility, discuss the limitations of each method, and explore the future direction for hemocompatible surface research.
Collapse
Affiliation(s)
- Megan Douglass
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
| | - Mark Garren
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
| | - Ryan Devine
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
| | - Arnab Mondal
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
| | - Hitesh Handa
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, GA, USA
| |
Collapse
|
13
|
Hemocompatibility challenge of membrane oxygenator for artificial lung technology. Acta Biomater 2022; 152:19-46. [PMID: 36089235 DOI: 10.1016/j.actbio.2022.09.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 08/25/2022] [Accepted: 09/04/2022] [Indexed: 11/24/2022]
Abstract
The artificial lung (AL) technology is one of the membrane-based artificial organs that partly augments lung functions, i.e. blood oxygenation and CO2 removal. It is generally employed as an extracorporeal membrane oxygenation (ECMO) device to treat acute and chronic lung-failure patients, and the recent outbreak of the COVID-19 pandemic has re-emphasized the importance of this technology. The principal component in AL is the polymeric membrane oxygenator that facilitates the O2/CO2 exchange with the blood. Despite the considerable improvement in anti-thrombogenic biomaterials in other applications (e.g., stents), AL research has not advanced at the same rate. This is partly because AL research requires interdisciplinary knowledge in biomaterials and membrane technology. Some of the promising biomaterials with reasonable hemocompatibility - such as emerging fluoropolymers of extremely low surface energy - must first be fabricated into membranes to exhibit effective gas exchange performance. As AL membranes must also demonstrate high hemocompatibility in tandem, it is essential to test the membranes using in-vitro hemocompatibility experiments before in-vivo test. Hence, it is vital to have a reliable in-vitro experimental protocol that can be reasonably correlated with the in-vivo results. However, current in-vitro AL studies are unsystematic to allow a consistent comparison with in-vivo results. More specifically, current literature on AL biomaterial in-vitro hemocompatibility data are not quantitatively comparable due to the use of unstandardized and unreliable protocols. Such a wide gap has been the main bottleneck in the improvement of AL research, preventing promising biomaterials from reaching clinical trials. This review summarizes the current state-of-the-art and status of AL technology from membrane researcher perspectives. Particularly, most of the reported in-vitro experiments to assess AL membrane hemocompatibility are compiled and critically compared to suggest the most reliable method suitable for AL biomaterial research. Also, a brief review of current approaches to improve AL hemocompatibility is summarized. STATEMENT OF SIGNIFICANCE: The importance of Artificial Lung (AL) technology has been re-emphasized in the time of the COVID-19 pandemic. The utmost bottleneck in the current AL technology is the poor hemocompatibility of the polymer membrane used for O2/CO2 gas exchange, limiting its use in the long-term. Unfortunately, most of the in-vitro AL experiments are unsystematic, irreproducible, and unreliable. There are no standardized in-vitro hemocompatibility characterization protocols for quantitative comparison between AL biomaterials. In this review, we tackled this bottleneck by compiling the scattered in-vitro data and suggesting the most suitable experimental protocol to obtain reliable and comparable hemocompatibility results. To the best of our knowledge, this is the first review paper focusing on the hemocompatibility challenge of AL technology.
Collapse
|
14
|
Melvin AC, Wick TV, Zang Y, Harea GT, Cancio LC, Reynolds MM, Batchinsky AI, Roberts TR. Development and Blood Compatibility of a Stable and Bioactive Metal-Organic Framework Composite Coating for Blood-Circulation Tubing. ACS Biomater Sci Eng 2022; 8:3438-3449. [PMID: 35776832 DOI: 10.1021/acsbiomaterials.2c00492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Medical devices that require substantial contact between blood and a foreign surface would be dramatically safer if constructed from materials that prevent clot formation and coagulation disturbance at the blood-biomaterial interface. Nitric oxide (NO), an endogenous inhibitor of platelet activation in the vascular endothelium, could provide anticoagulation at the blood-surface interface when applied to biomaterials. We investigated an application of a copper-based metal-organic framework, H3[(Cu4Cl)3(BTTri)8-(H2O)12]·72H2O where H3BTTri = 1,3,5-tris(1H-1,2,3-triazole-5-yl)benzene] (CuBTTri), which has been shown to be an effective catalyst to generate NO from S-nitrosothiols that are endogenously present in blood. A method was developed to apply a CuBTTri composite coating to Tygon medical tubing used for extracorporeal lung support devices. The stability and activity of the coating were evaluated during 72 h dynamic saline flow testing (1.5-2.5 L/min, n = 3) with scanning electron microscopy imaging and inductively coupled mass-spectroscopy analysis. Compatibility of the coating with whole blood was assessed with a panel of hemocompatibility tests during 6 h circulation of swine donor blood in an ex vivo circulation loop constructed with CuBTTri tubing or unmodified Tygon (1.5 L/min blood flow rate, n = 8/group). Thrombus deposition and catalytic activity of the CuBTTri tubing were assessed following blood exposure. The coating remained stable during 72 h saline flow experiments at clinically relevant flow rates. No adverse effects were observed relative to controls during blood compatibility testing, to include no significant changes in platelet count (p = 0.42), platelet activation indicated by P-selectin expression (p = 0.57), coagulation panel values, or methemoglobin fraction (p = 0.18) over the 6 h circulation period. CuBTTri within the coating generated NO following blood exposure in the presence of biologically relevant concentrations of an NO donor. CuBTTri composite coating was stable and blood compatible in this pilot study and requires further investigation of efficacy using in vivo models conducted with clinically relevant blood flow rates and study duration.
Collapse
Affiliation(s)
- Alyssa C Melvin
- Colorado State University, 301 West Pitkin Street, Fort Collins, Colorado 80523, United States
| | - Tracey V Wick
- Colorado State University, 301 West Pitkin Street, Fort Collins, Colorado 80523, United States
| | - Yanyi Zang
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, 2509 Kennedy Circle, San Antonio, Texas 78259, United States
| | - George T Harea
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, 2509 Kennedy Circle, San Antonio, Texas 78259, United States
| | - Leopoldo C Cancio
- US Army Institute of Surgical Research Burn Center, 3698 Chambers Road, Fort Sam Houston, Texas 78234, United States
| | - Melissa M Reynolds
- Colorado State University, 301 West Pitkin Street, Fort Collins, Colorado 80523, United States
| | - Andriy I Batchinsky
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, 2509 Kennedy Circle, San Antonio, Texas 78259, United States
| | - Teryn R Roberts
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, 2509 Kennedy Circle, San Antonio, Texas 78259, United States
| |
Collapse
|
15
|
Computer‐Aided Analysis of the Corrosion Inhibition by Carbon‐Based Thin‐Film Coating on Vascular Bare Metal Stent Models. ADVANCED THEORY AND SIMULATIONS 2022. [DOI: 10.1002/adts.202100626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
16
|
Roberts TR, Garren MRS, Wilson SN, Handa H, Batchinsky AI. Development and In Vitro Whole Blood Hemocompatibility Screening of Endothelium-Mimetic Multifunctional Coatings. ACS APPLIED BIO MATERIALS 2022; 5:2212-2223. [PMID: 35404571 DOI: 10.1021/acsabm.2c00073] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Multifunctional antithrombotic surface modifications for blood-contacting medical devices have emerged as a solution for foreign surface-mediated coagulation disturbance. Herein, we have developed and evaluated an endothelium-inspired strategy to reduce the thrombogenicity of medical plastics by imparting nitric oxide (NO) elution and heparin immobilization on the material surface. This dual-action approach (NO+Hep) was applied to polyethylene terephthalate (PET) blood incubation vials and compared to isolated modifications. Vials were characterized to evaluate NO surface flux as well as heparin density and activity. Hemocompatibility was assessed in vitro using whole blood from human donors. Compared to unmodified surfaces, blood incubated in the NO+Hep vials exhibited reduced platelet aggregation (15% decrease AUC, p = 0.040) and prolonged plasma clotting times (aPTT = 147% increase, p < 0.0001, prothrombin time = 5% increase, p = 0.0002). Prolongation of thromboelastography reaction time and elevated antifactor Xa levels in blood from NO+Hep versus PET vials suggests some heparin leaching from the vial surface, confirmed by post-blood incubation heparin density assessment. Results suggest NO+Hep surface modification is a promising approach for blood-contacting plastics; however, careful tuning of NO flux and heparin stabilization are essential and require assessment using human blood as performed here.
Collapse
Affiliation(s)
- Teryn R Roberts
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, 2509 Kennedy Circle Bldg 125, San Antonio, Texas 78235, United States
| | - Mark R S Garren
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States
| | - Sarah N Wilson
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States
| | - Hitesh Handa
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States.,Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia 30602, United States
| | - Andriy I Batchinsky
- Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, 2509 Kennedy Circle Bldg 125, San Antonio, Texas 78235, United States
| |
Collapse
|
17
|
Liu Y, Zhang F, Lang S, Yang L, Gao S, Wu D, Liu G, Wang Y. A Uniform and Robust Bioinspired Zwitterion Coating for Use in Blood-Contacting Catheters with Improved Anti-Inflammatory and Antithrombotic Properties. Macromol Biosci 2021; 21:e2100341. [PMID: 34644005 DOI: 10.1002/mabi.202100341] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 10/10/2021] [Indexed: 11/10/2022]
Abstract
Inflammation and thrombosis are two major complications of blood-contacting catheters that are used as extracorporeal circuits for hemodialysis and life-support systems. In clinical applications, complications can lead to increased mortality and morbidity rates. In this work, a biomimetic erythrocyte membrane zwitterion coating based on poly(2-methacryloyloxyethyl phosphorylcholine-co-dopamine methacrylate) (pMPCDA) copolymers is uniformly and robustly modified onto a polyvinyl chloride (PVC) catheter via mussel-inspired surface chemistry. The zwitterionic pMPCDA coating exhibits excellent antifouling activity and resists bacterial adhesion, fibrinogen adsorption, and platelet adhesion/activation. The material also demonstrates great hemocompatibility, cytocompatibility, and anticoagulation properties in vitro. Additionally, this biocompatible pMPCDA coating reduces in vivo foreign-body reactions by mitigating inflammatory response and collagen capsule formation, due to its outstanding ability to resist nonspecific protein adsorption. More importantly, when compared with a bare PVC catheter, the pMPCDA coating exhibits outstanding antithrombotic properties when tested in an ex vivo rabbit perfusion model. Thus, it is envisioned that this biomimetic erythrocyte membrane surface strategy will provide a promising way to mitigate inflammation and thrombosis caused by the use of blood-contacting catheters.
Collapse
Affiliation(s)
- Yuqi Liu
- Collage of Biomass Chemistry and Engineering, Sichuan University, Chengdu, 610065, China.,National Engineering Research Center of Clean Technology in Leather Industry, Sichuan University, Chengdu, 610065, China
| | - Fanjun Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China
| | - Shiying Lang
- Collage of Biomass Chemistry and Engineering, Sichuan University, Chengdu, 610065, China.,National Engineering Research Center of Clean Technology in Leather Industry, Sichuan University, Chengdu, 610065, China
| | - Li Yang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China
| | - Shuai Gao
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China.,Chengdu Daxan Innovative Medical Tech. Co., Ltd, Chengdu, 611135, China
| | - Dimeng Wu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China.,Chengdu Daxan Innovative Medical Tech. Co., Ltd, Chengdu, 611135, China
| | - Gongyan Liu
- Collage of Biomass Chemistry and Engineering, Sichuan University, Chengdu, 610065, China.,National Engineering Research Center of Clean Technology in Leather Industry, Sichuan University, Chengdu, 610065, China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China
| |
Collapse
|
18
|
Biomaterial and cellular implants:foreign surfaces where immunity and coagulation meet. Blood 2021; 139:1987-1998. [PMID: 34415324 DOI: 10.1182/blood.2020007209] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Accepted: 08/05/2021] [Indexed: 11/20/2022] Open
Abstract
Exposure of blood to a foreign surface in the form of a diagnostic or therapeutic biomaterial device or implanted cells or tissues, elicits an immediate, evolutionarily conserved thrombo-inflammatory response by the host. Primarily designed to protect against invading organisms following an injury, this innate response features instantaneous activation of several blood-borne, highly interactive and well-orchestrated cascades and cellular events that limit bleeding, destroy and eliminate the foreign substance/cells, and promote healing and a return to homeostasis via delicately balanced regenerative processes. In the setting of blood-contacting synthetic or natural biomaterials and implantation of foreign cells/tissues, innate responses are robust, albeit highly context-specific. Unfortunately, they tend to be less than adequately regulated by the host's natural anti-coagulant/anti-inflammatory pathways, thereby jeopardizing the functional integrity of the device, as well as the health of the host. Strategies to achieve biocompatibility with a sustained return to homeostasis, particularly while the device remains in situ and functional, continue to elude scientists and clinicians. In this review, some of the complex mechanisms by which biomaterials and cellular transplants provide a "hub" for activation and amplification of coagulation and immunity - thrombo-inflammation - will be discussed, with a view toward the development of innovative means of overcoming the innate challenges.
Collapse
|
19
|
Willers A, Arens J, Mariani S, Pels H, Maessen JG, Hackeng TM, Lorusso R, Swol J. New Trends, Advantages and Disadvantages in Anticoagulation and Coating Methods Used in Extracorporeal Life Support Devices. MEMBRANES 2021; 11:membranes11080617. [PMID: 34436380 PMCID: PMC8399034 DOI: 10.3390/membranes11080617] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 08/06/2021] [Accepted: 08/08/2021] [Indexed: 11/16/2022]
Abstract
The use of extracorporeal life support (ECLS) devices has significantly increased in the last decades. Despite medical and technological advancements, a main challenge in the ECLS field remains the complex interaction between the human body, blood, and artificial materials. Indeed, blood exposure to artificial surfaces generates an unbalanced activation of the coagulation cascade, leading to hemorrhagic and thrombotic events. Over time, several anticoagulation and coatings methods have been introduced to address this problem. This narrative review summarizes trends, advantages, and disadvantages of anticoagulation and coating methods used in the ECLS field. Evidence was collected through a PubMed search and reference scanning. A group of experts was convened to openly discuss the retrieved references. Clinical practice in ECLS is still based on the large use of unfractionated heparin and, as an alternative in case of contraindications, nafamostat mesilate, bivalirudin, and argatroban. Other anticoagulation methods are under investigation, but none is about to enter the clinical routine. From an engineering point of view, material modifications have focused on commercially available biomimetic and biopassive surfaces and on the development of endothelialized surfaces. Biocompatible and bio-hybrid materials not requiring combined systemic anticoagulation should be the future goal, but intense efforts are still required to fulfill this purpose.
Collapse
Affiliation(s)
- Anne Willers
- ECLS Centre, Cardio-Thoracic Surgery, and Cardiology Department, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan 25, 6229 HX Maastricht, The Netherlands; (S.M.); (J.G.M.); (R.L.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands;
- Correspondence: (A.W.); (J.S.); Tel.: +31-(0)649-07-9752 (A.W.); +49-(911)-398-0 (J.S.)
| | - Jutta Arens
- Engineering Organ Support Technologies Group, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands; (J.A.); (H.P.)
| | - Silvia Mariani
- ECLS Centre, Cardio-Thoracic Surgery, and Cardiology Department, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan 25, 6229 HX Maastricht, The Netherlands; (S.M.); (J.G.M.); (R.L.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands;
| | - Helena Pels
- Engineering Organ Support Technologies Group, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands; (J.A.); (H.P.)
| | - Jos G. Maessen
- ECLS Centre, Cardio-Thoracic Surgery, and Cardiology Department, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan 25, 6229 HX Maastricht, The Netherlands; (S.M.); (J.G.M.); (R.L.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands;
| | - Tilman M. Hackeng
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands;
- Department of Biochemistry, Faculty of Health, Medicine and Life, Maastricht University, P.O. Box 616, 6200 MD Maastricht, The Netherlands
| | - Roberto Lorusso
- ECLS Centre, Cardio-Thoracic Surgery, and Cardiology Department, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan 25, 6229 HX Maastricht, The Netherlands; (S.M.); (J.G.M.); (R.L.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands;
| | - Justyna Swol
- Department of Respiratory Medicine, Allergology and Sleep Medicine, Paracelsus Medical University, Ernst-Nathan Str. 1, 90419 Nuremberg, Germany
- Correspondence: (A.W.); (J.S.); Tel.: +31-(0)649-07-9752 (A.W.); +49-(911)-398-0 (J.S.)
| |
Collapse
|
20
|
Contraindications to the Initiation of Veno-Venous ECMO for Severe Acute Respiratory Failure in Adults: A Systematic Review and Practical Approach Based on the Current Literature. MEMBRANES 2021; 11:membranes11080584. [PMID: 34436348 PMCID: PMC8400963 DOI: 10.3390/membranes11080584] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 07/19/2021] [Accepted: 07/27/2021] [Indexed: 12/21/2022]
Abstract
(1) Background: Extracorporeal membrane oxygenation (ECMO) is increasingly used for acute respiratory failure with few absolute but many relative contraindications. The provider in charge often has a difficult time weighing indications and contraindications to anticipate if the patient will benefit from this treatment, a decision that often decides life and death for the patient. To assist in this process in coming to a good evidence-based decision, we reviewed the available literature. (2) Methods: We performed a systematic review through a literature search of the MEDLINE database of former and current absolute and relative contraindications to the initiation of ECMO treatment. (3) Results: The following relative and absolute contraindications were identified in the literature: absolute-refusal of the use of extracorporeal techniques by the patient, advanced stage of cancer, fatal intracerebral hemorrhage/cerebral herniation/intractable intracranial hypertension, irreversible destruction of the lung parenchyma without the possibility of transplantation, and contraindications to lung transplantation; relative-advanced age, immunosuppressed patients/pharmacological immunosuppression, injurious ventilator settings > 7 days, right-heart failure, hematologic malignancies, especially bone marrow transplantation and graft-versus-host disease, SAPS II score ≥ 60 points, SOFA score > 12 points, PRESERVE score ≥ 5 points, RESP score ≤ -2 points, PRESET score ≥ 6 points, and "do not attempt resuscitation" order (DN(A)R status). (4) Conclusions: We provide a simple-to-follow algorithm that incorporates absolute and relative contraindications to the initiation of ECMO treatment. This algorithm attempts to weigh pros and cons regarding the benefit for an individual patient and hopefully assists caregivers to make better, informed decisions.
Collapse
|
21
|
|
22
|
Garren MR, Ashcraft M, Qian Y, Douglass M, Brisbois EJ, Handa H. Nitric oxide and viral infection: Recent developments in antiviral therapies and platforms. APPLIED MATERIALS TODAY 2021; 22:100887. [PMID: 38620577 PMCID: PMC7718584 DOI: 10.1016/j.apmt.2020.100887] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 11/11/2020] [Accepted: 11/14/2020] [Indexed: 05/09/2023]
Abstract
Nitric oxide (NO) is a gasotransmitter of great significance to developing the innate immune response to many bacterial and viral infections, while also modulating vascular physiology. The generation of NO from the upregulation of endogenous nitric oxide synthases serves as an efficacious method for inhibiting viral replication in host defense and warrants investigation for the development of antiviral therapeutics. With increased incidence of global pandemics concerning several respiratory-based viral infections, it is necessary to develop broad therapeutic platforms for inhibiting viral replication and enabling more efficient host clearance, as well as to fabricate new materials for deterring viral transmission from medical devices. Recent developments in creating stabilized NO donor compounds and their incorporation into macromolecular scaffolds and polymeric substrates has created a new paradigm for developing NO-based therapeutics for long-term NO release in applications for bactericidal and blood-contacting surfaces. Despite this abundance of research, there has been little consideration of NO-releasing scaffolds and substrates for reducing passive transmission of viral infections or for treating several respiratory viral infections. The aim of this review is to highlight the recent advances in developing gaseous NO, NO prodrugs, and NO donor compounds for antiviral therapies; discuss the limitations of NO as an antiviral agent; and outline future prospects for guiding materials design of a next generation of NO-releasing antiviral platforms.
Collapse
Key Words
- ACE, angiotensin converting enzyme
- AP1, activator protein 1
- COVID-19
- COVID-19, coronavirus disease 2019
- ECMO, extracorporeal membrane oxygenation, FDA, United States Food and Drug Administration
- GNSO, S-nitrosoglutathione
- H1N1, influenza A virus subtype H1N1
- HI, Host Immunology
- HIV, human immunodeficiency virus
- HPV, human papillomavirus
- HSV, herpes simplex virus
- I/R, pulmonary ischemia-reperfusion
- IC50, inhibitory concentration 50
- IFN, interferon
- IFNγ, interferon gamma
- IKK, inhibitor of nuclear factor kappa B kinase
- IRF-1, interferon regulatory factor 1
- Inhalation therapy
- Medical Terminology: ARDS, acute respiratory distress syndrome
- NF-κB, nuclear factor kappa-light-chain enhancer of activated B cells
- NO, nitric oxide
- NOS, nitric oxide synthase
- Nitric Oxide and Related Compounds: eNOS/NOS 3, endothelial nitric oxide synthase
- Nitric oxide
- Other: DNA, deoxyribonucleic acid
- P38-MAPK, P38 mitogen-activated protein kinases
- PAMP, pathogen-associated molecular pattern
- PCV2, porcine circovirus type 2
- PHT, pulmonary hypertension
- PKR, protein kinase R
- RNA, ribonucleic acid
- RNI, reactive nitrogen intermediate
- RSNO, S-nitrosothiol
- SARS, severe acute respiratory syndrome
- SARS-CoV-2, severe acute respiratory syndrome coronavirus 2
- SNAP, S-nitroso-N-acetyl-penicillamine
- STAT-1, signal transducer and activator of transcription 1
- Severe acute respiratory distress
- TAK1, transforming growth factor β-activated kinases-1
- TLR, toll-like receptor
- VAP, ventilator associated pneumonia
- Viral infection
- Viruses: CVB3, coxsackievirus
- dsRNA, double stranded (viral) ribonucleic acid
- gNO, gaseous nitric oxide
- iNOS/NOS 2, inducible nitric oxide synthase
- mtALDH, mitochondrial aldehyde dehydrogenase
- nNOS/NOS 1, neuronal nitric oxide synthase
Collapse
Affiliation(s)
- Mark R Garren
- School of Chemical, Materials, and Biochemical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
| | - Morgan Ashcraft
- School of Chemical, Materials, and Biochemical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, GA, USA
| | - Yun Qian
- School of Chemical, Materials, and Biochemical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
| | - Megan Douglass
- School of Chemical, Materials, and Biochemical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
| | - Elizabeth J Brisbois
- School of Chemical, Materials, and Biochemical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
| | - Hitesh Handa
- School of Chemical, Materials, and Biochemical Engineering, College of Engineering, University of Georgia, Athens, GA, USA
| |
Collapse
|