Alexandrovskaya YM, Kasianenko EM, Sovetsky AA, Matveyev AL, Atyakshin DA, Patsap OI, Ignatiuk MA, Volodkin AV, Zaitsev VY. Optical coherence elastography with osmotically induced strains: Preliminary demonstration for express detection of cartilage degradation. JOURNAL OF BIOPHOTONICS 2024; 17:e202400016. [PMID: 38702959 DOI: 10.1002/jbio.202400016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 04/15/2024] [Accepted: 04/21/2024] [Indexed: 05/06/2024]
Abstract
Optical coherence elastography (OCE) demonstrated impressive abilities for diagnosing tissue types/states using differences in their biomechanics. Usually, OCE visualizes tissue deformation induced by some additional stimulus (e.g., contact compression or auxiliary elastic-wave excitation). We propose a new variant of OCE with osmotically induced straining (OIS-OCE) and demonstrate its application to assess various stages of proteoglycan content degradation in cartilage. The information-bearing signatures in OIS-OCE are the magnitude and rate of strains caused by the application of osmotically active solutions onto the sample surface. OCE examination of the induced strains does not require special tissue preparation, the osmotic stimulation is highly reproducible, and strains are observed in noncontact mode. Several minutes suffice to obtain a conclusion. These features are promising for intraoperative method usage when express assessment of tissue state is required during surgical operations. The "waterfall" images demonstrate the development of cumulative osmotic strains in control and degraded cartilage samples.
Collapse
Affiliation(s)
| | - Ekaterina M Kasianenko
- A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, Nizhny Novgorod, Russia
- National Research Center Kurchatov Institute, Moscow, Russia
| | - Alexander A Sovetsky
- A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Alexander L Matveyev
- A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Dmitry A Atyakshin
- Scientific and Educational Resource Center "Molecular Morphology", RUDN University, Moscow, Russia
| | - Olga I Patsap
- Scientific and Educational Resource Center "Molecular Morphology", RUDN University, Moscow, Russia
| | - Mikhail A Ignatiuk
- Scientific and Educational Resource Center "Molecular Morphology", RUDN University, Moscow, Russia
| | - Artem V Volodkin
- Scientific and Educational Resource Center "Molecular Morphology", RUDN University, Moscow, Russia
| | - Vladimir Y Zaitsev
- A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, Nizhny Novgorod, Russia
| |
Collapse
|
2
|
Tahsini V, Gil IC, Kling S. Storage-induced mechanical changes of porcine lenses assessed with optical coherence elastography and inverse finite element modeling. Front Bioeng Biotechnol 2024; 12:1398659. [PMID: 38938986 PMCID: PMC11208870 DOI: 10.3389/fbioe.2024.1398659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Accepted: 05/27/2024] [Indexed: 06/29/2024] Open
Abstract
Introduction In an effort of gaining a better understanding of the lens mechanics, ex vivo lenses samples are often used. Yet, ex vivo tissue might undergo important postmortem changes depending on the unavoidable preservation method employed. The purpose of this study was to assess how various storage conditions and the removal of the lens capsule affect the mechanical properties of ex vivo porcine lens samples. Methods A total of 81 freshly enucleated porcine eyes were obtained and divided into six groups and preserved differently. In the first three groups, the lens within the intact eye was preserved for 24 h by: (i) freezing at -80°C (n = 12), (ii) freezing at -20°C (n = 12), and (iii) refrigeration at +8°C (n = 12). In the remaining groups, the lenses were immediately extracted and treated as follows: (iv) kept intact, no storage (n = 12), (v) decapsulated, no storage (n = 21), and (vi) immersed in Minimum Essential Medium (MEM) at +8°C (n = 12) for 24 h. Frozen lenses were thawed at room temperature. Each lens was compressed between two glass lamella and subjected, first to a period of relaxation during which the compression force was recorded and second to an oscillating micro-compression while the deformation was recorded with a total of 256 subsequent B-scans via optical coherence tomography. The corresponding axial strain was retrieved via phase-sensitive image processing and subsequently used as input for an inverse finite element analysis (iFEA) to retrieve the visco-hyperelastic material properties of the lenses. Results After freezing at temperatures of -80°C and -20°C, the cortical strains increased by 14% (p = 0.01) and 34% (p < 0.001), and the nuclear strains decreased by 17% (p = 0.014) and 36% (p < 0.001), compared to the lenses tested immediately after postmortem, respectively. According to iFEA, this resulted from an increased ratio of the nuclear: cortical E-modulus (4.06 and 7.06) in -80°C and -20°C frozen lenses compared to fresh lenses (3.3). Decapsulation had the largest effect on the material constant C10, showing an increase both in the nucleus and cortex. Preservation of the intact eye in the refrigerator induced the least mechanical alterations in the lens, compared to the intact fresh condition. Discussion Combining iFEA with optical coherence elastography allowed us to identify important changes in the lens mechanics induced after different preserving ex vivo methods.
Collapse
Affiliation(s)
- Vahoura Tahsini
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Iulen Cabeza Gil
- Aragón Institute of Engineering Research (i3A), University of Zaragoza, Zaragoza, Spain
| | - Sabine Kling
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| |
Collapse
|
3
|
Wang C, Zhu J, Ma J, Meng X, Ma Z, Fan F. Optical coherence elastography and its applications for the biomechanical characterization of tissues. JOURNAL OF BIOPHOTONICS 2023; 16:e202300292. [PMID: 37774137 DOI: 10.1002/jbio.202300292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 09/19/2023] [Accepted: 09/27/2023] [Indexed: 10/01/2023]
Abstract
The biomechanical characterization of the tissues provides significant evidence for determining the pathological status and assessing the disease treatment. Incorporating elastography with optical coherence tomography (OCT), optical coherence elastography (OCE) can map the spatial elasticity distribution of biological tissue with high resolution. After the excitation with the external or inherent force, the tissue response of the deformation or vibration is detected by OCT imaging. The elastogram is assessed by stress-strain analysis, vibration amplitude measurements, and quantification of elastic wave velocities. OCE has been used for elasticity measurements in ophthalmology, endoscopy, and oncology, improving the precision of diagnosis and treatment of disease. In this article, we review the OCE methods for biomechanical characterization and summarize current OCE applications in biomedicine. The limitations and future development of OCE are also discussed during its translation to the clinic.
Collapse
Affiliation(s)
- Chongyang Wang
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China
| | | | - Jiawei Ma
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China
| | - Xiaochen Meng
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China
| | - Zongqing Ma
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China
| | - Fan Fan
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China
| |
Collapse
|
4
|
Frigelli M, Büchler P, Kling S. Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography. Front Bioeng Biotechnol 2023; 11:1272097. [PMID: 38026898 PMCID: PMC10680454 DOI: 10.3389/fbioe.2023.1272097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 10/20/2023] [Indexed: 12/01/2023] Open
Abstract
Purpose: Corneal cross-linking (CXL) has recently been used with promising results to positively affect corneal refractive power in the treatment of hyperopia and mild myopia. However, understanding and predicting the optomechanical changes induced by this procedure are challenging. Methods: We applied ambient pressure modulation based optical coherence elastography (OCE) to quantify the refractive and mechanical effects of patterned CXL and their relationship to energy delivered during the treatment on porcine corneas. Three different patterned treatments were performed, designed according to Zernike polynomial functions (circle, astigmatism, coma). In addition, three different irradiation protocols were analyzed: standard Dresden CXL (fluence of 5.4 J/cm2), accelerated CXL (fluence of 5.4 J/cm2), and high-fluence CXL (fluence of 16.2 J/cm2). The axial strain distribution in the stroma induced by ocular inflation (Δp = 30 mmHg) was quantified, maps of the anterior sagittal curvature were constructed and cylindrical refraction was assessed. Results: Thirty minutes after CXL, there was a statistically significant increase in axial strain amplitude (p < 0.050) and a reduction in sagittal curvature (p < 0.050) in the regions treated with all irradiation patterns compared to the non-irradiated ones. Thirty-6 hours later, the non-irradiated regions showed compressive strains, while the axial strain in the CXL-treated regions was close to zero, and the reduction in sagittal curvature observed 30 minutes after the treatment was maintained. The Dresden CXL and accelerated CXL produced comparable amounts of stiffening and refractive changes (p = 0.856), while high-fluence CXL produced the strongest response in terms of axial strain (6.9‰ ± 1.9‰) and refractive correction (3.4 ± 0.9 D). Tripling the energy administered during CXL resulted in a 2.4-fold increase in the resulting refractive correction. Conclusion: OCE showed that refractive changes and alterations in corneal biomechanics are directly related. A patient-specific selection of both, the administered UV fluence and the irradiation pattern during CXL is promising to allow customized photorefractive corrections in the future.
Collapse
Affiliation(s)
- Matteo Frigelli
- Computational Bioengineering Group, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Philippe Büchler
- Computational Bioengineering Group, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Sabine Kling
- Computational Bioengineering Group, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
- Institute for Biomedical Engineering, ITET Department, ETH Zürich, Zürich, Switzerland
| |
Collapse
|
5
|
Cabeza Gil I, Tahsini V, Kling S. Viscoelastic properties of porcine lenses using optical coherence elastography and inverse finite element analysis. Exp Eye Res 2023:109558. [PMID: 37385534 DOI: 10.1016/j.exer.2023.109558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 06/02/2023] [Accepted: 06/26/2023] [Indexed: 07/01/2023]
Abstract
The mechanical properties of the crystalline lens are crucial in determining the changes in lens shape that occur during the accommodation process and are also a major factor in the development of the two most prevalent age-related diseases of the lens, presbyopia and cataracts. However, a comprehensive understanding of these properties is currently lacking. Previous methods for characterizing the mechanical properties of the lens have been limited by the amount of data that could be collected during each test and the lack of complex material modeling. These limitations were mainly caused by the lack of imaging techniques that can provide data for the entire crystalline lens and the need for more complex models to describe the non-linear behavior of the lens. To address these issues, we characterized the mechanical properties of 13 porcine lenses during an ex vivo micro-controlled-displacement compression experiment using optical coherence elastography (OCE) and inverse finite element analysis (iFEA). OCE allowed us to quantify the internal strain distribution of the lens and differentiate between the different parts of the lens, while iFEA enabled us to implement an advanced material model to characterize the viscoelasticity of the lens nucleus and the relative stiffness gradient in the lens. Our findings revealed a pronounced and rapid viscoelastic behavior in the lens nucleus (g1 = 0.39 ± 0.13, τ1 = 5.01 ± 2.31 s) and identified the lens nucleus as the stiffest region, with a stiffness 4.42 ± 1.20 times greater than the anterior cortex and 3.47 ± 0.82 times greater than the posterior cortex. However, due to the complex nature of lens properties, it may be necessary to employ multiple tests simultaneously for a more comprehensive understanding of the crystalline lens.
Collapse
Affiliation(s)
- Iulen Cabeza Gil
- Aragón Institute of Engineering Research (i3A), University of Zaragoza, Spain
| | - Vahoura Tahsini
- ARTORG Center for Biomedical Engineering Research, University of Bern, Switzerland
| | - Sabine Kling
- ARTORG Center for Biomedical Engineering Research, University of Bern, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland.
| |
Collapse
|
6
|
Zaitsev VY, Sovetsky AA, Matveyev AL, Matveev LA, Shabanov D, Salamatova VY, Karavaikin PA, Vassilevski YV. Application of compression optical coherence elastography for characterization of human pericardium: A pilot study. JOURNAL OF BIOPHOTONICS 2023; 16:e202200253. [PMID: 36397665 DOI: 10.1002/jbio.202200253] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 10/23/2022] [Accepted: 11/16/2022] [Indexed: 06/16/2023]
Abstract
The recent impressive progress in Compression Optical Coherence Elastography (C-OCE) demonstrated diverse biomedical applications, comprising ophthalmology, oncology, etc. High resolution of C-OCE enables spatially resolved characterization of elasticity of rather thin (thickness < 1 mm) samples, which previously was impossible. Besides Young's modulus, C-OCE enables obtaining of nonlinear stress-strain dependences for various tissues. Here, we report the first application of C-OCE to nondestructively characterize biomechanics of human pericardium, for which data of conventional tensile tests are very limited and controversial. C-OCE revealed pronounced differences among differently prepared pericardium samples. Ample understanding of the influence of chemo-mechanical treatment on pericardium biomechanics is very important because of rapidly growing usage of own patients' pericardium for replacement of aortic valve leaflets in cardio-surgery. The figure demonstrates differences in the tangent Young's modulus after glutaraldehyde-induced cross-linking for two pericardium samples. One sample was over-stretched during the preparation, which caused some damage to the tissue.
Collapse
Affiliation(s)
- Vladimir Y Zaitsev
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Alexander A Sovetsky
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Alexander L Matveyev
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Lev A Matveev
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Dmitry Shabanov
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Victoria Y Salamatova
- Sechenov University, Moscow, Russia
- Sirius University of Science and Technology, Sochi, Russia
| | | | - Yuri V Vassilevski
- Sechenov University, Moscow, Russia
- Sirius University of Science and Technology, Sochi, Russia
- Marchuk Institute of Numerical Mathematics, Russian Academy of Sciences, Moscow, Russia
| |
Collapse
|
7
|
Li F, Wang K, Liu Z. In Vivo Biomechanical Measurements of the Cornea. BIOENGINEERING (BASEL, SWITZERLAND) 2023; 10:bioengineering10010120. [PMID: 36671692 PMCID: PMC9854753 DOI: 10.3390/bioengineering10010120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Revised: 01/11/2023] [Accepted: 01/13/2023] [Indexed: 01/18/2023]
Abstract
In early corneal examinations, the relationships between the morphological and biomechanical features of the cornea were unclear. Although consistent links have been demonstrated between the two in certain cases, these are not valid in many diseased states. An accurate assessment of the corneal biomechanical properties is essential for understanding the condition of the cornea. Studies on corneal biomechanics in vivo suggest that clinical problems such as refractive surgery and ectatic corneal disease are closely related to changes in biomechanical parameters. Current techniques are available to assess the mechanical characteristics of the cornea in vivo. Accordingly, various attempts have been expended to obtain the relevant mechanical parameters from different perspectives, using the air-puff method, ultrasound, optical techniques, and finite element analyses. However, a measurement technique that can comprehensively reflect the full mechanical characteristics of the cornea (gold standard) has not yet been developed. We review herein the in vivo measurement techniques used to assess corneal biomechanics, and discuss their advantages and limitations to provide a comprehensive introduction to the current state of technical development to support more accurate clinical decisions.
Collapse
Affiliation(s)
- Fanshu Li
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Health Science Center, Peking University, Beijing 100191, China
| | - Kehao Wang
- Beijing Advanced Innovation Center for Biomedical Engineering, School of Engineering Medicine, Beihang University, Beijing 100191, China
| | - Ziyuan Liu
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Health Science Center, Peking University, Beijing 100191, China
- Correspondence:
| |
Collapse
|
8
|
Co-axial acoustic-based optical coherence vibrometry probe for the quantification of resonance frequency modes in ocular tissue. Sci Rep 2022; 12:18834. [PMID: 36336702 PMCID: PMC9637745 DOI: 10.1038/s41598-022-21978-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 10/07/2022] [Indexed: 11/08/2022] Open
Abstract
We present a co-axial acoustic-based optical coherence vibrometry probe (CoA-OCV) for vibro-acoustic resonance quantification in biological tissues. Sample vibrations were stimulated via a loudspeaker, and pre-compensation was used to calibrate the acoustic spectrum. Sample vibrations were measured via phase-sensitive swept-source optical coherence tomography (OCT). Resonance frequencies of corneal phantoms were measured at varying intraocular pressures (IOP), and dependencies on Young´s Modulus (E), phantom thickness and IOP were observed. Cycling IOP revealed hysteresis. For E = 0.3 MPa, resonance frequencies increased with IOP at a rate of 3.9, 3.7 and 3.5 Hz/mmHg for varied thicknesses and 1.7, 2.5 and 2.8 Hz/mmHg for E = 0.16 MPa. Resonance frequencies increased with thickness at a rate of 0.25 Hz/µm for E = 0.3 MPa, and 0.40 Hz/µm for E = 0.16 MPa. E showed the most predominant impact in the shift of the resonance frequencies. Full width at half maximum (FWHM) of the resonance modes increased with increasing thickness and decreased with increasing E. Only thickness and E contributed to the variance of FWHM. In rabbit corneas, resonance frequencies of 360-460 Hz were observed. The results of the current study demonstrate the feasibility of CoA-OCV for use in future OCT-V studies.
Collapse
|
9
|
Mekonnen T, Lin X, Zevallos-Delgado C, Singh M, Aglyamov SR, Coulson-Thomas V, Larin KV. Longitudinal assessment of the effect of alkali burns on corneal biomechanical properties using optical coherence elastography. JOURNAL OF BIOPHOTONICS 2022; 15:e202200022. [PMID: 35460537 PMCID: PMC11057918 DOI: 10.1002/jbio.202200022] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 03/29/2022] [Accepted: 04/22/2022] [Indexed: 06/14/2023]
Abstract
Eye injury due to alkali burn is a severe ocular trauma that can profoundly affect corneal structure and function, including its biomechanical properties. Here, we assess the changes in the mechanical behavior of mouse corneas in response to alkali-induced injury by conducting longitudinal measurements using optical coherence elastography (OCE). A non-contact air-coupled ultrasound transducer was used to induce elastic waves in control and alkali-injured mouse corneas in vivo, which were imaged with phase-sensitive optical coherence tomography. Corneal mechanical properties were estimated using a modified Rayleigh-Lamb wave model, and results show that Young's modulus of alkali-burned corneas were significantly greater than that of their healthy counterparts on days 7 (p = 0.029) and 14 (p = 0.026) after injury. These findings, together with the changes in the shear viscosity coefficient postburn, indicate that the mechanical properties of the alkali-burned cornea are significantly modulated during the wound healing process.
Collapse
Affiliation(s)
- Taye Mekonnen
- Department of Biomedical Engineering, University of Houston, 3517 Cullen Blvd., Room 2027, Houston, TX 77204, USA
| | - Xiao Lin
- College of Optometry, University of Houston, 4901 Calhoun Road, Houston, TX 77204‑2020, USA
| | - Christian Zevallos-Delgado
- Department of Biomedical Engineering, University of Houston, 3517 Cullen Blvd., Room 2027, Houston, TX 77204, USA
| | - Manmohan Singh
- Department of Biomedical Engineering, University of Houston, 3517 Cullen Blvd., Room 2027, Houston, TX 77204, USA
| | - Salavat R. Aglyamov
- Department of Mechanical Engineering, University of Houston, Houston, TX 77204, USA
| | - Vivien Coulson-Thomas
- College of Optometry, University of Houston, 4901 Calhoun Road, Houston, TX 77204‑2020, USA
| | - Kirill V. Larin
- Department of Biomedical Engineering, University of Houston, 3517 Cullen Blvd., Room 2027, Houston, TX 77204, USA
| |
Collapse
|
10
|
Torres-Netto EA, Hafezi F, Kling S. Intracorneal Ring Segment Implantation Results in Corneal Mechanical Strengthening Visualized With Optical Coherence Elastography. J Refract Surg 2022; 38:459-464. [PMID: 35858197 DOI: 10.3928/1081597x-20220608-01] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To quantify the mechanical impact of intracorneal ring segment (ICRS) implantation of different dimensions in an ex vivo eye model. METHODS A total of 30 enucleated porcine eyes were assigned to ICRS implantation (thickness: 300 µm, angle: 120°, 210°, or 325°), tunnel creation only, or virgin control groups. For mechanical evaluation, each globe was mounted on a customized holder and intraocular pressure (IOP) was increased in steps of 0.5 mm Hg from 15 to 17 mm Hg, simulating physiologic diurnal IOP fluctuations. At each step, an optical coherence tomography volume scan was recorded. Deformations between subsequent scans and the locally induced axial strains were analyzed using a vector-based phase difference method. The effective E-modulus was derived from the overall induced strain as a measure of global mechanical impact. RESULTS ICRS implantation increased the effective E-modulus from 146 and 163 kPa in virgin and tunnel-only eyes to 149, 192, and 330 kPa in eyes that received a 5-mm optical zone ICRS with 120°, 210°, and 325° arc length, respectively; and to 209 kPa in a 6-mm optical zone ICRS with 325° arc length. The most consistent effect was a shift toward positive strains in the posterior stroma by 0.1% to 0.46% (factor 1.15 to 2.15) after ICRS surgery. CONCLUSIONS ICRS implantation reduces the overall tissue strain under the load of the IOP and provokes posterior tissue relaxation. This effect is more prominent the longer the arc length and the smaller the optical zone of the ICRS is. ICRS have not only a geometrical, but also a mechanical impact on corneal tissue. This behavior might have clinical implications when ICRS implantation is performed in biomechanically weakened keratoconic corneas. [J Refract Surg. 2022;38(7):459-464.].
Collapse
|
11
|
Novel Elastography-Inspired Approach to Angiographic Visualization in Optical Coherence Tomography. PHOTONICS 2022. [DOI: 10.3390/photonics9060401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
In this paper, we present a new approach to contrast-agent-free angiographic visualization in optical coherence tomography (OCT). The proposed approach has much in common with imaging of local interframe strains in OCT-based elastography and utilizes the fact that the interframe motion of blood particles leads to discontinuity of strains within the vessel cross section. By this reasoning, we call this approach “elastography-inspired”. Here, we first elucidate the essence and main features of the elastography-inspired approach using numerical simulation of OCT data. The simulations allow one to introduce both moving scatterers imitating blood flow in vessels as well as various masking motions imitating natural motions of living “solid” tissue surrounding the vessels. Second, using real OCT signals, we present comparative results of angiographic processing using the proposed elastography-inspired approach and a realization of OCA based on high-pass filtering of temporal variability of a series of OCT B-scans. The two methods can use the same initial dataset and the high-pass filtering OCA has already been routinely applied in both animal experiments and on patients. The new elastography-inspired method has a similar computational efficiency, and it is intrinsically able to compensate spatially-inhomogeneous masking tissue motions and demonstrates high robustness with respect to motion artefacts. Thus, the new approach looks very promising for enabling wider application of OCA in both laboratory studies on animals and, most importantly, for wider clinical applications on patients.
Collapse
|
12
|
Torres-Netto EA, Kling S. Corneal Strain Induced by Intracorneal Ring Segment Implantation Visualized With Optical Coherence Elastography. J Refract Surg 2022; 38:210-216. [PMID: 35275004 DOI: 10.3928/1081597x-20211214-01] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To record the axial strain field in the cornea directly after creating a stromal tunnel and implanting an intracorneal ring segment (ICRS). METHODS Freshly enucleated porcine eyes were obtained and assigned to either ICRS implantation, tunnel creation only, or virgin control groups. Immediately after manual tunnel creation and ICRS positioning, the entire eye globe was mounted on a customized holder and intraocular pressure (IOP) was adjusted to 15 mm Hg. Then, IOP was inreased to 20 mm Hg, in steps of 1 mm Hg. At each step, an optical coherence tomography volume scan was recorded. Displacements between subsequent scans were retrieved using a vector-based phase difference method. The induced corneal strain direction was determined by taking the axial gradient. In addition, corneal surface was detected and sagittal curvature maps computed. RESULTS Corneal tissue presented a localized compressive strain in the direct vicinity of the stromal tunnel, which was independent of IOP change. The central and peripheral (exterior to the ICRS) cornea demonstrated compressive strains on IOP increase, and tensile strains on IOP decrease. ICRS implantation induced an annular-shaped tensile strain at its inner border, particularly during IOP increase. The compressive strains close to the tunnel remained after ICRS implantation. Corneal curvature changes were concentrated on regions where strain was induced. CONCLUSIONS ICRS implantation induces localized strains in the regions subjected to refractive changes, suggesting that corneal strain and curvature are directly related. Studying corneal strain in response to surgical intervention may provide new insights on underlying working principles. [J Refract Surg. 2022;38(3):210-216.].
Collapse
|
13
|
Singh M, Zvietcovich F, Larin KV. Introduction to optical coherence elastography: tutorial. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2022; 39:418-430. [PMID: 35297425 PMCID: PMC10052825 DOI: 10.1364/josaa.444808] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 01/25/2022] [Indexed: 06/03/2023]
Abstract
Optical coherence elastography (OCE) has seen rapid growth since its introduction in 1998. The past few decades have seen tremendous advancements in the development of OCE technology and a wide range of applications, including the first clinical applications. This tutorial introduces the basics of solid mechanics, which form the foundation of all elastography methods. We then describe how OCE measurements of tissue motion can be used to quantify tissue biomechanical parameters. We also detail various types of excitation methods, imaging systems, acquisition schemes, and data processing algorithms and how various parameters associated with each step of OCE imaging can affect the final quantitation of biomechanical properties. Finally, we discuss the future of OCE, its potential, and the next steps required for OCE to become an established medical imaging technology.
Collapse
Affiliation(s)
- Manmohan Singh
- Biomedical Engineering, University of Houston, Houston, Texas 77204, USA
| | - Fernando Zvietcovich
- Biomedical Engineering, University of Houston, Houston, Texas 77204, USA
- Department of Engineering, Pontificia Universidad Catolica del Peru, San Miguel, Lima 15088, Peru
| | - Kirill V. Larin
- Biomedical Engineering, University of Houston, Houston, Texas 77204, USA
- Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, Texas 77030, USA
| |
Collapse
|
14
|
Ge GR, Tavakol B, Usher DB, Adler DC, Rolland JP, Parker KJ. Assessing corneal cross-linking with reverberant 3D optical coherence elastography. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:026003. [PMID: 35166086 PMCID: PMC8843360 DOI: 10.1117/1.jbo.27.2.026003] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 01/27/2022] [Indexed: 06/14/2023]
Abstract
SIGNIFICANCE Corneal cross-linking (CXL) is a well-known procedure for treating certain eye disorders such as keratoconus. However, characterization of the biomechanical changes in the cornea as a result of this procedure is still under active research. Specifically, there is a clinical need for high-resolution characterization of individual corneal layers. AIM A high-resolution elastography method in conjunction with a custom optical coherence tomography system is used to track these biomechanical changes in individual corneal layers. Pre- and post-treatment analysis for both low-dose and high-dose CXL experiments are performed. APPROACH A recently developed elastography technique that utilizes the theory of reverberant shear wave fields, with optical coherence tomography as the modality, is applied to pig corneas ex vivo to evaluate elasticity changes associated with corneal CXL. Sets of low-dose and high-dose CXL treatments are evaluated before and after treatments with three pairs of pig corneas per experiment. RESULTS The reverberant three-dimensional (3D) optical coherence elastography (OCE) technique can identify increases in elasticity associated with both low-dose and high-dose CXL treatments. There is a notable graphical difference between low-dose and high-dose treatments. In addition, the technique is able to identify which layers of the cornea are potentially affected by the CXL procedure and provides insight into the nonlinearity of the elasticity changes. CONCLUSIONS The reverberant 3D OCE technique can identify depth-resolved changes in elasticity of the cornea associated with CXL procedures. This method could be translated to assess and monitor CXL efficacy in various clinical settings.
Collapse
Affiliation(s)
- Gary R. Ge
- University of Rochester, The Institute of Optics, Rochester, New York, United States
| | - Behrouz Tavakol
- Glaukos Corporation, San Clemente, California, United States
| | - David B. Usher
- Glaukos Corporation, San Clemente, California, United States
| | | | - Jannick P. Rolland
- University of Rochester, The Institute of Optics, Rochester, New York, United States
- University of Rochester, Department of Biomedical Engineering, Rochester, New York, United States
- University of Rochester, Center for Visual Science, Rochester, New York, United States
| | - Kevin J. Parker
- University of Rochester, Department of Biomedical Engineering, Rochester, New York, United States
- University of Rochester, Department of Electrical and Computer Engineering, Rochester, New York, United States
| |
Collapse
|
15
|
Alexandrovskaya Y, Baum O, Sovetsky A, Matveyev A, Matveev L, Sobol E, Zaitsev V. Optical Coherence Elastography as a Tool for Studying Deformations in Biomaterials: Spatially-Resolved Osmotic Strain Dynamics in Cartilaginous Samples. MATERIALS 2022; 15:ma15030904. [PMID: 35160851 PMCID: PMC8838169 DOI: 10.3390/ma15030904] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 01/14/2022] [Accepted: 01/20/2022] [Indexed: 12/15/2022]
Abstract
This paper presents a recently developed variant of phase-resolved Optical Coherence Elastography (OCE) enabling non-contact visualization of transient local strains of various origins in biological tissues and other materials. In this work, we demonstrate the possibilities of this new technique for studying dynamics of osmotically-induced strains in cartilaginous tissue impregnated with optical clearing agents (OCA). For poroelastic water-containing biological tissues, application of non-isotonic OCAs, various contrast additives, as well as drug solutions administration, may excite transient spatially-inhomogeneous strain fields of high magnitude in the tissue bulk, initiating mechanical and structural alterations. The range of the strain reliably observed by OCE varied from ±10−3 to ±0.4 for diluted and pure glycerol, correspondingly. The OCE-technique used made it possible to reveal previously inaccessible details of the complex spatio-temporal evolution of alternating-sign osmotic strains at the initial stages of agent diffusion. Qualitatively different effects produced by particular hydrophilic OCAs, such as glycerol and iohexol, are discussed, as well as concentration-dependent differences. Overall, the work demonstrates the unique abilities of the new OCE-modality in providing a deeper insight in real-time kinetics of osmotically-induced strains relevant to a broad range of biomedical applications.
Collapse
Affiliation(s)
- Yulia Alexandrovskaya
- Institute of Photon Technologies, Federal Scientific Research Center “Crystallography and Photonics”, Russian Academy of Sciences, 2 Pionerskaya Street, Troitsk, 108840 Moscow, Russia;
- Correspondence:
| | - Olga Baum
- Institute of Photon Technologies, Federal Scientific Research Center “Crystallography and Photonics”, Russian Academy of Sciences, 2 Pionerskaya Street, Troitsk, 108840 Moscow, Russia;
| | - Alexander Sovetsky
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova Street, 603950 Nizhny Novgorod, Russia; (A.S.); (A.M.); (L.M.); (V.Z.)
| | - Alexander Matveyev
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova Street, 603950 Nizhny Novgorod, Russia; (A.S.); (A.M.); (L.M.); (V.Z.)
| | - Lev Matveev
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova Street, 603950 Nizhny Novgorod, Russia; (A.S.); (A.M.); (L.M.); (V.Z.)
| | - Emil Sobol
- UCI Health Beckman Laser Institute & Medical Clinic, 1002 Health Sciences Rd., Irvine, CA 92612, USA;
| | - Vladimir Zaitsev
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova Street, 603950 Nizhny Novgorod, Russia; (A.S.); (A.M.); (L.M.); (V.Z.)
| |
Collapse
|
16
|
Kling S. In-Vivo Measurement of Ocular Deformation in Response to Ambient Pressure Modulation. Front Bioeng Biotechnol 2021; 9:759588. [PMID: 34869269 PMCID: PMC8634479 DOI: 10.3389/fbioe.2021.759588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Accepted: 10/26/2021] [Indexed: 11/20/2022] Open
Abstract
A novel approach is presented for the non-invasive quantification of axial displacement and strain in corneal and anterior crystalline lens tissue in response to a homogenous ambient pressure change. A spectral domain optical coherence tomography (OCT) system was combined with a custom-built set of swimming goggles and a pressure control unit to acquire repetitive cross-sectional scans of the anterior ocular segment before, during and after ambient pressure modulation. The potential of the technique is demonstrated in vivo in a healthy human subject. The quantification of the dynamic deformation response, consisting of axial displacement and strain, demonstrated an initial retraction of the eye globe (−0.43 to −1.22 nm) and a subsequent forward motion (1.99 nm) in response to the pressure change, which went along with a compressive strain induced in the anterior crystalline lens (−0.009) and a tensile strain induced in the cornea (0.014). These mechanical responses appear to be the result of a combination of whole eye motion and eye globe expansion. The latter simulates a close-to-physiologic variation of the intraocular pressure and makes the detected mechanical responses potentially relevant for clinical follow-up and pre-surgical screening. The presented measurements are a proof-of-concept that non-contact low-amplitude ambient pressure modulation induces tissue displacement and strain that is detectable in vivo with OCT. To take full advantage of the high spatial resolution this imaging technique could offer, further software and hardware optimization will be necessary to overcome the current limitation of involuntary eye motions.
Collapse
Affiliation(s)
- Sabine Kling
- OPTIC Team, Computer Vision Laboratory, ITET Department, ETH Zürich, Zürich, Switzerland
| |
Collapse
|
17
|
Matveyev AL, Matveev LA, Moiseev AA, Sovetsky AA, Gelikonov GV, Zaitsev VY. Simulating scan formation in multimodal optical coherence tomography: angular-spectrum formulation based on ballistic scattering of arbitrary-form beams. BIOMEDICAL OPTICS EXPRESS 2021; 12:7599-7615. [PMID: 35003855 PMCID: PMC8713662 DOI: 10.1364/boe.440739] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 10/11/2021] [Accepted: 10/13/2021] [Indexed: 06/14/2023]
Abstract
We present a computationally highly efficient full-wave spectral model of OCT-scan formation with the following features: allowance of arbitrary phase-amplitude profile of illuminating beams; absence of paraxial approximation; utilization of broadly used approximation of ballistic scattering by discrete scatterers without limitations on their density/location and scattering strength. The model can easily incorporate the wave decay, dispersion, measurement noises with given signal-to-noise ratios and arbitrary inter-scan displacements of scatterers. We illustrate several of such abilities, including comparative simulations of OCT-scans for Bessel versus Gaussian beams, presence of arbitrary aberrations at the tissue boundary and various scatterer motions. The model flexibility and computational efficiency allow one to accurately study various properties of OCT-scans for developing new methods of their processing in various biomedical applications.
Collapse
Affiliation(s)
- Alexander L. Matveyev
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| | - Lev A. Matveev
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| | - Aleksandr A. Moiseev
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| | - Alexander A. Sovetsky
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| | - Grigory V. Gelikonov
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| | - Vladimir Y. Zaitsev
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| |
Collapse
|
18
|
Kling S, Torres-Netto EA, Abdshahzadeh H, Espana EM, Hafezi F. Collagen V insufficiency in a mouse model for Ehlers Danlos-syndrome affects viscoelastic biomechanical properties explaining thin and brittle corneas. Sci Rep 2021; 11:17362. [PMID: 34462473 PMCID: PMC8405695 DOI: 10.1038/s41598-021-96775-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 08/09/2021] [Indexed: 11/30/2022] Open
Abstract
Ehlers–Danlos syndrome (EDS) is a genetic disease leading to abnormalities in mechanical properties of different tissues. Here we quantify corneal biomechanical properties in an adult classic EDS mouse model using two different measurement approaches suited for murine corneal mechanical characterization and relate differences to stromal structure using Second Harmonic Generation (SHG) microscopy. Quasi-static Optical Coherence Elastography (OCE) was conducted non-invasively during ambient pressure modulation by − 3 mmHg. 2D-extensometry measurements was conducted invasively consisting of a pre-conditioning cycle, a stress-relaxation test and a rupture test. In a total of 28 eyes from a Col5a1+/− mouse model and wild-type C57BL/6 littermates (wt), Col5a1+/− corneas were thinner when compared to wt, (125 ± 11 vs 148 ± 10 μm, respectively, p < 0.001). Short-term elastic modulus was significantly increased in OCE (506 ± 88 vs 430 ± 103 kPa, p = 0.023), and the same trend was observed in 2D-extensometry (30.7 ± 12.1 kPa vs 21.5 ± 5.7, p = 0.057). In contrast, in stress relaxation tests, Col5a1+/− corneas experienced a stronger relaxation (55% vs 50%, p = 0.01). SHG microscopy showed differences in forward and backward scattered signal indicating abnormal collagen fibrils in Col5a1+/− corneas. We propose that disturbed collagen fibril structure in Col5a1+/− corneas affects the viscoelastic properties. Results presented here support clinical findings, in which thin corneas with global ultrastructural alterations maintain a normal corneal shape.
Collapse
Affiliation(s)
- Sabine Kling
- OPTIC-Team, Computer Vision Laboratory, Department of Information Technology and Electrical Engineering, ETH Zurich, Sternwartstrasse 7, 8092, Zurich, Switzerland.
| | - Emilio A Torres-Netto
- Laboratory of Ocular Cell Biology, CABMM, University of Zurich, Zurich, Switzerland.,ELZA Institute AG, Dietikon/Zurich, Switzerland.,Department of Ophthalmology, Paulista School of Medicine, Federal University of Sao Paulo, São Paulo, Brazil.,Faculty of Medicine, University of Geneva, Geneva, Switzerland.,Department of Ophthalmology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Hormoz Abdshahzadeh
- Laboratory of Ocular Cell Biology, CABMM, University of Zurich, Zurich, Switzerland.,ELZA Institute AG, Dietikon/Zurich, Switzerland.,Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Edgar M Espana
- Dept. of Ophthalmology, Morsani College of Medicine, University of South Florida, Tampa, FL, USA
| | - Farhad Hafezi
- Laboratory of Ocular Cell Biology, CABMM, University of Zurich, Zurich, Switzerland.,ELZA Institute AG, Dietikon/Zurich, Switzerland.,Faculty of Medicine, University of Geneva, Geneva, Switzerland.,Dept. of Ophthalmology, USC Roski Eye Institute, Keck School of Medicine, USC Los Angeles, Los Angeles, USA.,Dept. of Ophthalmology, Wenzhou Medical University, Wenzhou, China
| |
Collapse
|
19
|
Wilson A, Jones J, Marshall J. Interferometric Ex Vivo Evaluation of the Spatial Changes to Corneal Biomechanics Introduced by Topographic CXL: A Pilot Study. J Refract Surg 2021; 37:263-273. [PMID: 34038664 DOI: 10.3928/1081597x-20210203-01] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
PURPOSE To determine the efficacy of interferometry for examining the spatial changes to the corneal biomechanical response to simulated intraocular pressure (IOP) fluctuations that occur after corneal cross-linking (CXL) applied in different topographic locations. METHODS Displacement speckle pattern interferometry (DSPI) was used to measure the total anterior surface displacement of human and porcine corneas in response to pressure variations up to 1 mm Hg from a baseline pressure of 16.5 mm Hg, both before and after CXL treatment, which was applied in isolated topographic locations (10-minute riboflavin soak [VibeX-Xtra; Avedro, Inc], 8-minute ultraviolet-A exposure at 15 mW/cm2). Alterations to biomechanics were evaluated by directly comparing the responses before and after treatment for each cornea. RESULTS Before CXL, the corneal response to loading indicated spatial variability in mechanical properties. CXL treatments had a variable effect on the corneal response to loading dependent on the location of treatment, with reductions in regional displacement of up to 80% in response to a given pressure increase. CONCLUSIONS Selectively cross-linking in different topographic locations introduces position-specific changes to mechanical properties that could potentially be used to alter the refractive power of the cornea. Changes to the biomechanics of the cornea after CXL are complex and appear to vary significantly depending on treatment location and initial biomechanics. Hence, further investigations are required on a larger number of corneas to allow the development of customized treatment protocols. In this study, laser interferometry was demonstrated to be an effective and valuable tool to achieve this. [J Refract Surg. 2021;37(4):263-273.].
Collapse
|
20
|
Blackburn BJ, Rollins AM, Dupps WJ. Biomechanics of Ophthalmic Crosslinking. Transl Vis Sci Technol 2021; 10:8. [PMID: 34328498 PMCID: PMC8327749 DOI: 10.1167/tvst.10.5.8] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Accepted: 06/19/2021] [Indexed: 12/12/2022] Open
Abstract
Crosslinking involves the formation of bonds between polymer chains, such as proteins. In biological tissues, these bonds tend to stiffen the tissue, making it more resistant to mechanical degradation and deformation. In ophthalmology, the crosslinking phenomenon is being increasingly harnessed and explored as a treatment strategy for treating corneal ectasias, keratitis, degenerative myopia, and glaucoma. This review surveys the multitude of exogenous crosslinking strategies reported in the literature, both "light" (involving light energy) and "dark" (involving non-photic chemical processes), and explores their mechanisms, cytotoxicity, and stage of translational development. The spectrum of ophthalmic applications described in the literature is then discussed, with particular attention to proposed therapeutic mechanisms in the cornea and sclera. The mechanical effects of crosslinking are then discussed in the context of their proposed site and scale of action. Biomechanical characterization of the crosslinking effect is needed to more thoroughly address knowledge gaps in this area, and a review of reported methods for biomechanical characterization is presented with an attempt to assess the sensitivity of each method to crosslinking-mediated changes using data from the experimental and clinical literature. Biomechanical measurement methods differ in spatial resolution, mechanical sensitivity, suitability for detecting crosslinking subtypes, and translational readiness and are central to the effort to understand the mechanistic link between crosslinking methods and clinical outcomes of candidate therapies. Data on differences in the biomechanical effect of different crosslinking protocols and their correspondence to clinical outcomes are reviewed, and strategies for leveraging measurement advances predicting clinical outcomes of crosslinking procedures are discussed. Advancing the understanding of ophthalmic crosslinking, its biomechanical underpinnings, and its applications supports the development of next-generation crosslinking procedures that optimize therapeutic effect while reducing complications.
Collapse
Affiliation(s)
- Brecken J. Blackburn
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Andrew M. Rollins
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - William J. Dupps
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
- Cole Eye Institute, Cleveland Clinic, Cleveland, OH, USA
- Department of Ophthalmology, Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, OH, USA
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
21
|
Nair A, Singh M, Aglyamov S, Larin KV. Heartbeat optical coherence elastography: corneal biomechanics in vivo. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-200338LR. [PMID: 33624461 PMCID: PMC7901857 DOI: 10.1117/1.jbo.26.2.020502] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 01/19/2021] [Indexed: 05/02/2023]
Abstract
SIGNIFICANCE Mechanical assessment of the cornea can provide important structural and functional information regarding its health. Current clinically available tools are limited in their efficacy at measuring corneal mechanical properties. Elastography allows for the direct estimation of mechanical properties of tissues in vivo but is generally performed using external excitation force. AIM To show that heartbeat optical coherence elastography (Hb-OCE) can be used to assess the mechanical properties of the cornea in vivo. APPROACH Hb-OCE was utilized to detect Hb-induced deformations in the rabbit cornea in vivo without the need for external excitation. Furthermore, we demonstrate how this technique can distinguish corneal stiffness between untreated (UT) and crosslinked (CXL) tissue. RESULTS Our results demonstrate that stiffness changes in the cornea can be detected using only the Hb-induced deformations in the cornea. Additionally, we demonstrate a statistically significant difference in strain between the UT and CXL corneas. CONCLUSIONS Hb-OCE may be an effective tool for assessing the mechanical properties of the cornea in vivo without the need for external excitation. This tool may be effective for clinical assessment of corneal mechanical properties because it only requires optical coherence tomography imaging and data processing.
Collapse
Affiliation(s)
- Achuth Nair
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Manmohan Singh
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Salavat Aglyamov
- University of Houston, Department of Mechanical Engineering, Houston, Texas, United States
| | - Kirill V. Larin
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
- Address all correspondence to Kirill V. Larin,
| |
Collapse
|
22
|
Nair A, Singh M, Aglyamov SR, Larin KV. Heartbeat OCE: corneal biomechanical response to simulated heartbeat pulsation measured by optical coherence elastography. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:1-9. [PMID: 32372574 PMCID: PMC7199791 DOI: 10.1117/1.jbo.25.5.055001] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Accepted: 04/24/2020] [Indexed: 05/04/2023]
Abstract
SIGNIFICANCE It is generally agreed that the corneal mechanical properties are strongly linked to many eye diseases and could be used to assess disease progression and response to therapies. Elastography is the most notable method of assessing corneal mechanical properties, but it generally requires some type of external excitation to induce a measurable displacement in the tissue. AIM We present Heartbeat Optical Coherence Elastography (Hb-OCE), a truly passive method that can measure the elasticity of the cornea based on intrinsic corneal displacements induced by the heartbeat. APPROACH Hb-OCE measurements were performed in untreated and UV-A/riboflavin cross-linked porcine corneas ex vivo, and a distinct difference in strain was detected. Furthermore, a partially cross-linked cornea was also assessed, and the treated and untreated areas were similarly distinguished. RESULTS Our results suggest that Hb-OCE can spatially map displacements in the cornea induced by small fluctuations in intraocular pressure, similar to what is induced by the heartbeat. CONCLUSIONS The described technique opens the possibility for completely passive and noncontact in vivo assessment of corneal stiffness.
Collapse
Affiliation(s)
- Achuth Nair
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Manmohan Singh
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Salavat R. Aglyamov
- University of Houston, Department of Mechanical Engineering, Houston, Texas, United States
| | - Kirill V. Larin
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
- Address all correspondence to Kirill V. Larin, E-mail:
| |
Collapse
|
23
|
Ambekar YS, Singh M, Zhang J, Nair A, Aglyamov SR, Scarcelli G, Larin KV. Multimodal quantitative optical elastography of the crystalline lens with optical coherence elastography and Brillouin microscopy. BIOMEDICAL OPTICS EXPRESS 2020; 11:2041-2051. [PMID: 32341865 PMCID: PMC7173892 DOI: 10.1364/boe.387361] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 02/27/2020] [Accepted: 03/05/2020] [Indexed: 05/03/2023]
Abstract
Assessing the biomechanical properties of the crystalline lens can provide crucial information for diagnosing disease and guiding precision therapeutic interventions. Existing noninvasive methods have been limited to global measurements. Here, we demonstrate the quantitative assessment of the elasticity of crystalline lens with a multimodal optical elastography technique, which combines dynamic wave-based optical coherence elastography (OCE) and Brillouin microscopy to overcome the drawbacks of individual modalities. OCE can provide direct measurements of tissue elasticity rapidly and quantitatively, but it is a challenge to image transparent samples such as the lens because this technique relies on backscattered light. On the other hand, Brillouin microscopy can map the longitudinal modulus with micro-scale resolution in transparent samples. However, the relationship between Brillouin-deduced modulus and Young's modulus is not straightforward and sample dependent. By combining these two techniques, we can calibrate Brillouin measurements with OCE, based on the same sample, allowing us to completely map the Young's modulus of the crystalline lens. The combined system was first validated with tissue-mimicking gelatin phantoms of varying elasticities (N = 9). The OCE data was used to calibrate the Brillouin shift measurements and subsequently map the Young's modulus of the phantoms. After validation, OCE and Brillouin measurements were performed on ex-vivo porcine lenses (N = 6), and the Young's modulus of the lenses was spatially mapped. The results show a strong correlation between Young's moduli measured by OCE and longitudinal moduli measured by Brillouin microscopy. The correlation coefficient R was 0.98 for the phantoms and 0.94 for the lenses, respectively. The mean Young's modulus of the anterior and posterior lens was 1.98 ± 0.74 kPa and 2.93 ± 1.13 kPa, respectively, and the Young's modulus of the lens nucleus was 11.90 ± 2.94 kPa. The results presented in this manuscript open a new way for truly quantitative biomechanical mapping of optically transparent (or low scattering) tissues in 3D.
Collapse
Affiliation(s)
| | - Manmohan Singh
- Department of Biomedical Engineering, University of Houston, Houston, TX 77030, USA
| | - Jitao Zhang
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | - Achuth Nair
- Department of Biomedical Engineering, University of Houston, Houston, TX 77030, USA
| | - Salavat R. Aglyamov
- Department of Mechanical Engineering, University of Houston, Houston, TX 77030, USA
| | - Giuliano Scarcelli
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | - Kirill V. Larin
- Department of Biomedical Engineering, University of Houston, Houston, TX 77030, USA
- Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, TX 77030, USA
| |
Collapse
|