1
|
Saud B, Guha K, Iannacci J, Selishchev S, Sengupta P, Dutta A. Design and simulation of a microfluidics-based artificial glomerular ultrafiltration unit to reduce cell-induced fouling. Artif Organs 2024; 48:1404-1417. [PMID: 39078122 DOI: 10.1111/aor.14834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 07/10/2024] [Accepted: 07/11/2024] [Indexed: 07/31/2024]
Abstract
BACKGROUND The microfluidic-based Glomerulus-on-Chips (GoC) are mostly cell based, that is, 3D cell culture techniques are used to culture glomerular cells in order to mimic glomerular ultrafiltration. These chips require high maintenance to keep cell viability intact. There have been some approaches to build non-cell-based GoCs but many of these approaches have the drawback of membrane fouling. This article presents a structural design and simulation study of a dialysate free microfluidic channel for replicating the function of the human glomerular filtration barrier. The key advancement of the current work is addressing the fouling issue by combining a pre-filter to eliminate cellular components and performing filtration on the blood plasma. METHODS The Laminar Flow Mixture Model in COMSOL Multiphysics 5.6 has been utilized to simulate the behavior of blood flow in the microchannels. The geometrical effect of microchannels on the separation of the filtrate was investigated. The velocity at the inlet of the microchannel and pore size of the filtration membrane are varied to see the change in outflow and filtration fraction. RESULTS The efficiency of the device is calculated in terms of the filtration fraction (FF%) formed. Simulation results show that the filtrate obtained is ~20% of the plasma flow rate in the channel, which resembles the glomerular filtration fraction. CONCLUSION Given that it is not dependent on the functionality of grown cells, the proposed device is anticipated to have a longer lifespan due to its non-cell-based design. The device's cost can be reduced by avoiding cell cultivation inside of it. It can be integrated as a glomerular functional unit with other units of kidney model to build a fully developed artificial kidney.
Collapse
Affiliation(s)
- Bhagyashree Saud
- Department of Electronics and Communication Engineering, National Institute of Technology, Silchar, India
| | - Koushik Guha
- Department of Electronics and Communication Engineering, National Institute of Technology, Silchar, India
| | - Jacopo Iannacci
- Center for Sensors and Devices (SD), Fondazione Bruno Kessler (FBK), Trento, Italy
| | - Sergei Selishchev
- National Research University of Electronic Technology (MIET), Moscow, Russia
| | | | - Arindam Dutta
- RG Stone Urology & Laparoscopic Hospital, Kolkata, India
| |
Collapse
|
2
|
Liu Y, Yu G, Liang H, Sun W, Zhang L, Mauk MG, Li H, Chen L. Detection and identification of SARS-CoV-2 and influenza a based on microfluidic technology. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:4582-4589. [PMID: 38919038 DOI: 10.1039/d4ay00847b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/27/2024]
Abstract
As of now, the global COVID-19 pandemic caused by SARS-CoV-2, which began in 2019, has been effectively controlled. However, the symptoms of influenza A virus infection were similar to those of SARS-CoV-2 infection, but they required different treatment approaches. To make the detection more accurate and the treatment more targeted. We developed a system that integrates RPA and CRISPR assays, allowing for the rapid, highly specific, and sensitive detection and differentiation of SARS-CoV-2, H1N1, and H3N2. Under isothermal amplification conditions, the RPA-CRISPR Cas12a detection system achieved a detection limit as low as 5 copies per μL, demonstrating excellent specificity. The measurement time was approximately 30 minutes. The RPA-CRISPR Cas12a detection system combined with the microfluidic chip we designed to simultaneously detect three viruses, providing a potential solution for efficient and reliable diagnosis.
Collapse
Affiliation(s)
- Yujie Liu
- Shandong Provincial Key Laboratory of Animal Resistance Biology, College of Life Sciences, Shandong Normal University, Jinan Shandong, China.
| | - Guanliu Yu
- Shandong Provincial Key Laboratory of Animal Resistance Biology, College of Life Sciences, Shandong Normal University, Jinan Shandong, China.
| | - Hongkun Liang
- Shandong Provincial Key Laboratory of Animal Resistance Biology, College of Life Sciences, Shandong Normal University, Jinan Shandong, China.
| | - Wenbo Sun
- Shandong Key Laboratory of Animal Disease Control and Breeding, Institute of Animal Science and Veterinary Medicine, Shandong Academy of Agricultural Sciences, Jinan Shandong, China
| | - Lulu Zhang
- College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, China
| | - Michael G Mauk
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, Pennsylvania, 19104, USA
| | - Hua Li
- Shandong Provincial Key Laboratory of Animal Resistance Biology, College of Life Sciences, Shandong Normal University, Jinan Shandong, China.
| | - Lei Chen
- Shandong Provincial Key Laboratory of Animal Resistance Biology, College of Life Sciences, Shandong Normal University, Jinan Shandong, China.
| |
Collapse
|
3
|
Klement WJN, Savino E, Browne WR, Verpoorte E. In-line Raman imaging of mixing by herringbone grooves in microfluidic channels. LAB ON A CHIP 2024; 24:3498-3507. [PMID: 38920114 PMCID: PMC11235414 DOI: 10.1039/d4lc00115j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/27/2024]
Abstract
The control over fluid flow achievable in microfluidic devices creates opportunities for applications in many fields. In simple microchannels, flow is purely laminar when one solvent is used, and hence, achieving reliable mixing is an important design consideration. Integration of structures, such as grooves, into the channels to act as static mixers is a commonly used approach. The mixing induced by these structures can be validated by determining concentration profiles in microfluidic channels following convergence of solvent streams from separate inlets. Spatially resolved characterisation is therefore necessary and requires in-line analysis methods. Here we report a line-focused illumination approach to provide operando, spatially resolved Raman spectra across the width of channels in the analysis of single- and multi-phase liquid systems and chemical reactions. A scientific complementary metal oxide semiconductor (sCMOS) sensor is used to overcome smearing encountered during spectral readout of images with CCD sensors. Isotopically labelled probes, in otherwise identical flow streams, show that z-confocality limits the spatial resolution and certainty as to the extent of mixing that can be achieved. These limitations are overcome using fast chemical reactions between reagents entering a microchannel in separate solvent streams. We show here that the progression of a chemical reaction, for which only the product is observable, is a powerful approach to determine the extent of mixing in a microchannel. Specifically resonance enhancement of Raman scattering from a product formed allows for determination of the true efficiency of mixing over the length and width of microchannels. Raman spectral images obtained by line-focused illumination show onset of mixing by observing the product of reagents entering from the separate inlets. Mixing is initially off-centre and immediately before the apex of the first groove of the static mixer, and then evolves along the entire width of the channel after a full cycle of grooves.
Collapse
Affiliation(s)
- W J Niels Klement
- Molecular Inorganic Chemistry, Stratingh Institute for Chemistry, Faculty of Science and Engineering, University of Groningen, Nijenborgh 4, 9747 AG, Groningen, The Netherlands.
- Pharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen, Antonius Deusinglaan 1, 9700 AD, Groningen, The Netherlands
| | - Elia Savino
- Molecular Inorganic Chemistry, Stratingh Institute for Chemistry, Faculty of Science and Engineering, University of Groningen, Nijenborgh 4, 9747 AG, Groningen, The Netherlands.
| | - Wesley R Browne
- Molecular Inorganic Chemistry, Stratingh Institute for Chemistry, Faculty of Science and Engineering, University of Groningen, Nijenborgh 4, 9747 AG, Groningen, The Netherlands.
| | - Elisabeth Verpoorte
- Pharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen, Antonius Deusinglaan 1, 9700 AD, Groningen, The Netherlands
| |
Collapse
|
4
|
Elomaa P, Ojalehto T, Kumar D, Jokinen V, Saavalainen P. Manually pressurized droplet digital PCR chip for rapid SARS-CoV-2 diagnostics. BIOMICROFLUIDICS 2024; 18:014106. [PMID: 38420041 PMCID: PMC10901548 DOI: 10.1063/5.0180394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 02/02/2024] [Indexed: 03/02/2024]
Abstract
Droplet digital PCR (ddPCR) is a technique in which PCR reaction is divided into thousands of nanoliter-sized droplets and has proven to be a great tool in virus diagnostics. Compared to the gold standard system quantitative real-time PCR (RT-qPCR), ddPCR functions particularly well when dealing with samples with low template counts, such as viral concentration. This feature makes the technique suitable for early detection of the virus. In this study, a novel portable PDMS ddPCR chip is introduced. The chip functions without external pumps using manual pressurization with a multichannel pipet. The created droplets are monodispersed and form a monolayer on the chip's collection chamber, from where they can be effortlessly imaged. Droplets were analyzed and counted using artificial intelligence. The use of the manually pressurized chip was demonstrated for a SARS-CoV-2 assay, which takes advantage of isothermal strand invasion-based amplification (SIBA) technology, allowing quick and accurate, even point-of-care analysis of the sample. The results demonstrate that SIBA assays can be divided into nanoliter-sized droplets and used as quantitative assays, giving an approximation of the samples' viral count.
Collapse
Affiliation(s)
| | | | | | - Ville Jokinen
- Department of Chemistry and Materials Science, Aalto University School of Chemical Engineering, Tietotie 3, Espoo 02150, Finland
| | | |
Collapse
|
5
|
Mumtaz Z, Rashid Z, Ali A, Arif A, Ameen F, AlTami MS, Yousaf MZ. Prospects of Microfluidic Technology in Nucleic Acid Detection Approaches. BIOSENSORS 2023; 13:584. [PMID: 37366949 DOI: 10.3390/bios13060584] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/30/2023] [Accepted: 04/07/2023] [Indexed: 06/28/2023]
Abstract
Conventional diagnostic techniques are based on the utilization of analyte sampling, sensing and signaling on separate platforms for detection purposes, which must be integrated to a single step procedure in point of care (POC) testing devices. Due to the expeditious nature of microfluidic platforms, the trend has been shifted toward the implementation of these systems for the detection of analytes in biochemical, clinical and food technology. Microfluidic systems molded with substances such as polymers or glass offer the specific and sensitive detection of infectious and noninfectious diseases by providing innumerable benefits, including less cost, good biological affinity, strong capillary action and simple process of fabrication. In the case of nanosensors for nucleic acid detection, some challenges need to be addressed, such as cellular lysis, isolation and amplification of nucleic acid before its detection. To avoid the utilization of laborious steps for executing these processes, advances have been deployed in this perspective for on-chip sample preparation, amplification and detection by the introduction of an emerging field of modular microfluidics that has multiple advantages over integrated microfluidics. This review emphasizes the significance of microfluidic technology for the nucleic acid detection of infectious and non-infectious diseases. The implementation of isothermal amplification in conjunction with the lateral flow assay greatly increases the binding efficiency of nanoparticles and biomolecules and improves the limit of detection and sensitivity. Most importantly, the deployment of paper-based material made of cellulose reduces the overall cost. Microfluidic technology in nucleic acid testing has been discussed by explicating its applications in different fields. Next-generation diagnostic methods can be improved by using CRISPR/Cas technology in microfluidic systems. This review concludes with the comparison and future prospects of various microfluidic systems, detection methods and plasma separation techniques used in microfluidic devices.
Collapse
Affiliation(s)
- Zilwa Mumtaz
- KAM School of Life Sciences, Forman Christian College University, Ferozpur Road, Lahore 54600, Pakistan
| | - Zubia Rashid
- Pure Health Laboratory, Mafraq Hospital, Abu Dhabi 1227788, United Arab Emirates
| | - Ashaq Ali
- State Key Laboratory of Virology, Center for Biosafety MegaScience, Wuhan Institute of Virology, Chinese Academy of Sciences, Wuhan 430071, China
| | - Afsheen Arif
- Karachi Institute of Biotechnology and Genetic Engineering (KIBGE), University of Karachi, Karachi 75270, Pakistan
| | - Fuad Ameen
- Department of Botany and Microbiology, College of Science, King Suad University, Riyadh 11451, Saudi Arabia
| | - Mona S AlTami
- Biology Department, College of Science, Qassim University, Burydah 52571, Saudi Arabia
| | - Muhammad Zubair Yousaf
- KAM School of Life Sciences, Forman Christian College University, Ferozpur Road, Lahore 54600, Pakistan
| |
Collapse
|
6
|
Mantri D, Wymenga L, van Turnhout J, van Zeijl H, Zhang G. Manipulation, Sampling and Inactivation of the SARS-CoV-2 Virus Using Nonuniform Electric Fields on Micro-Fabricated Platforms: A Review. MICROMACHINES 2023; 14:345. [PMID: 36838044 PMCID: PMC9967285 DOI: 10.3390/mi14020345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 01/21/2023] [Accepted: 01/21/2023] [Indexed: 06/18/2023]
Abstract
Micro-devices that use electric fields to trap, analyze and inactivate micro-organisms vary in concept, design and application. The application of electric fields to manipulate and inactivate bacteria and single-celled organisms has been described extensively in the literature. By contrast, the effect of such fields on viruses is not well understood. This review explores the possibility of using existing methods for manipulating and inactivating larger viruses and bacteria, for smaller viruses, such as SARS-CoV-2. It also provides an overview of the theoretical background. The findings may be used to implement new ideas and frame experimental parameters that optimize the manipulation, sampling and inactivation of SARS-CoV-2 electrically.
Collapse
Affiliation(s)
- Devashish Mantri
- Department Biomedical Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands
| | - Luutzen Wymenga
- Department Microelectronics, Delft University of Technology, 2628 CD Delft, The Netherlands
| | - Jan van Turnhout
- Department Material Science Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands
| | - Henk van Zeijl
- Department Microelectronics, Delft University of Technology, 2628 CD Delft, The Netherlands
| | - Guoqi Zhang
- Department Microelectronics, Delft University of Technology, 2628 CD Delft, The Netherlands
| |
Collapse
|
7
|
Maryam S, Ul Haq I, Yahya G, Ul Haq M, Algammal AM, Saber S, Cavalu S. COVID-19 surveillance in wastewater: An epidemiological tool for the monitoring of SARS-CoV-2. Front Cell Infect Microbiol 2023; 12:978643. [PMID: 36683701 PMCID: PMC9854263 DOI: 10.3389/fcimb.2022.978643] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Accepted: 11/03/2022] [Indexed: 01/06/2023] Open
Abstract
The coronavirus disease 2019 (COVID-19) pandemic has prompted a lot of questions globally regarding the range of information about the virus's possible routes of transmission, diagnostics, and therapeutic tools. Worldwide studies have pointed out the importance of monitoring and early surveillance techniques based on the identification of viral RNA in wastewater. These studies indicated the presence of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in human feces, which is shed via excreta including mucus, feces, saliva, and sputum. Subsequently, they get dumped into wastewater, and their presence in wastewater provides a possibility of using it as a tool to help prevent and eradicate the virus. Its monitoring is still done in many regions worldwide and serves as an early "warning signal"; however, a lot of limitations of wastewater surveillance have also been identified.
Collapse
Affiliation(s)
- Sajida Maryam
- Department of Biosciences, The Commission on Science and Technology for Sustainable Development in the South (COMSATS) University Islamabad (CUI), Islamabad, Pakistan
| | - Ihtisham Ul Haq
- Department of Biosciences, The Commission on Science and Technology for Sustainable Development in the South (COMSATS) University Islamabad (CUI), Islamabad, Pakistan
- Department of Physical Chemistry and Polymers Technology, Silesian University of Technology, Gliwice, Poland
- Joint Doctoral School, Silesian University of Technology, Gliwice, Poland
| | - Galal Yahya
- Department of Microbiology and Immunology, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt
| | - Mehboob Ul Haq
- Department of Biosciences, The Commission on Science and Technology for Sustainable Development in the South (COMSATS) University Islamabad (CUI), Islamabad, Pakistan
| | - Abdelazeem M. Algammal
- Department of Bacteriology, Immunology, and Mycology, Faculty of Veterinary Medicine, Suez Canal University, Ismailia, Egypt
| | - Sameh Saber
- Department of Pharmacology, Faculty of Pharmacy, Delta University for Science and Technology, Gamasa, Egypt
| | - Simona Cavalu
- Faculty of Medicine and Pharmacy, University of Oradea, Oradea, Romania
| |
Collapse
|
8
|
Abedini-Nassab R, Emamgholizadeh A. Controlled Transport of Magnetic Particles and Cells Using C-Shaped Magnetic Thin Films in Microfluidic Chips. MICROMACHINES 2022; 13:2177. [PMID: 36557476 PMCID: PMC9783610 DOI: 10.3390/mi13122177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 12/02/2022] [Accepted: 12/07/2022] [Indexed: 06/17/2023]
Abstract
Single-cell analysis is an emerging discipline that has shown a transformative impact in cell biology in the last decade. Progress in this field requires systems capable of accurately moving the cells and particles in a controlled manner. Here, we present a microfluidic platform equipped with C-shaped magnetic thin films to precisely transport magnetic particles in a tri-axial rotating magnetic field. This innovative system, compared to the other rivals, offers numerous advantages. The magnetic particles repel each other to prevent undesired cluster formation. Many particles move synced with the external rotating magnetic field, which results in highly parallel controlled particle transport. We show that the particle transport in this system is analogous to electron transport and Ohm's law in electrical circuits. The proposed magnetic transport pattern is carefully studied using both simulations and experiments for various parameters, including the magnetic field characteristics, particle size, and gap size in the design. We demonstrate the appropriate transport of both magnetic beads and magnetized living cells. We also show a pilot mRNA-capturing experiment with barcode-carrying magnetic beads. The introduced chip offers fundamental potential applications in the fields of single-cell biology and bioengineering.
Collapse
|
9
|
Chen S, Sun Y, Fan F, Chen S, Zhang Y, Zhang Y, Meng X, Lin JM. Present status of microfluidic PCR chip in nucleic acid detection and future perspective. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
10
|
Donia A, Furqan Shahid M, Hassan SU, Shahid R, Ahmad A, Javed A, Nawaz M, Yaqub T, Bokhari H. Integration of RT-LAMP and Microfluidic Technology for Detection of SARS-CoV-2 in Wastewater as an Advanced Point-of-Care Platform. FOOD AND ENVIRONMENTAL VIROLOGY 2022; 14:364-373. [PMID: 35508752 PMCID: PMC9067896 DOI: 10.1007/s12560-022-09522-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 04/04/2022] [Indexed: 05/21/2023]
Abstract
Development of lab-on-a-chip (LOC) system based on integration of reverse transcription loop-mediated isothermal amplification (RT-LAMP) and microfluidic technology is expected to speed up SARS-CoV-2 diagnostics allowing early intervention. In the current work, reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) and RT-LAMP assays were performed on extracted RNA of seven wastewater samples from COVID-19 hotspots. RT‑LAMP assay was also performed on wastewater samples without RNA extraction. Current detection of SARS-CoV-2 is mainly by RT-qPCR of ORF (ORF1ab) and N genes so we targeted both to find the best target gene for SARS-CoV-2 detection. We also performed RT-LAMP with/without RNA extraction inside microfluidic device to target both genes. Positivity rates of RT-qPCR and RT-LAMP performed on extracted RNA were 100.0% (7/7) and 85.7% (6/7), respectively. RT-qPCR results revealed that all 7 wastewater samples were positive for N gene (Ct range 37-39), and negative for ORF1ab, suggesting that N gene could be the best target gene for SARS-CoV-2 detection. RT-LAMP of N and ORF (ORF1a) genes performed on wastewater samples without RNA extraction indicated that all 7 samples remains pink (negative). The color remains pink in all microchannels except microchannels which subjected to RT-LAMP for targeting N region after RNA extraction (yellow color) in 6 out of 7 samples. This study shows that SARS-CoV-2 was successfully detected from wastewater samples using RT-LAMP in microfluidic chips. This study brings the novelty involving the use of wastewater samples for detection of SARS-CoV-2 without previous virus concentration and with/without RNA extraction.
Collapse
Affiliation(s)
- Ahmed Donia
- Department of Biosciences, Faculty of Science, COMSATS University Islamabad, Islamabad, Pakistan
| | - Muhammad Furqan Shahid
- Institute of Microbiology, University of Veterinary and Animal Sciences, Lahore, Pakistan
| | - Sammer-ul Hassan
- Department of Mechanical Engineering, University of Hong Kong, Pok Fu Lam, Hong Kong, Hong Kong
| | - Ramla Shahid
- Department of Biosciences, Faculty of Science, COMSATS University Islamabad, Islamabad, Pakistan
| | | | - Aneela Javed
- Healthcare Biotechnology, Atta-ur-Rahman School of Applied Biosciences, National University of Science and Technology, Islamabad, Pakistan
| | - Muhammad Nawaz
- Institute of Microbiology, University of Veterinary and Animal Sciences, Lahore, Pakistan
| | - Tahir Yaqub
- Institute of Microbiology, University of Veterinary and Animal Sciences, Lahore, Pakistan
| | - Habib Bokhari
- Department of Biosciences, Faculty of Science, COMSATS University Islamabad, Islamabad, Pakistan
- Kohsar University Murree, Murree, Pakistan
| |
Collapse
|
11
|
Gamage SST, Pahattuge TN, Wijerathne H, Childers K, Vaidyanathan S, Athapattu US, Zhang L, Zhao Z, Hupert ML, Muller RM, Muller-Cohn J, Dickerson J, Dufek D, Geisbrecht BV, Pathak H, Pessetto Z, Gan GN, Choi J, Park S, Godwin AK, Witek MA, Soper SA. Microfluidic affinity selection of active SARS-CoV-2 virus particles. SCIENCE ADVANCES 2022; 8:eabn9665. [PMID: 36170362 PMCID: PMC9519043 DOI: 10.1126/sciadv.abn9665] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Accepted: 08/10/2022] [Indexed: 06/07/2023]
Abstract
We report a microfluidic assay to select active severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral particles (VPs), which were defined as intact particles with an accessible angiotensin-converting enzyme 2 receptor binding domain (RBD) on the spike (S) protein, from clinical samples. Affinity selection of SARS-CoV-2 particles was carried out using injection molded microfluidic chips, which allow for high-scale production to accommodate large-scale screening. The microfluidic contained a surface-bound aptamer directed against the virus's S protein RBD to affinity select SARS-CoV-2 VPs. Following selection (~94% recovery), the VPs were released from the chip's surface using a blue light light-emitting diode (89% efficiency). Selected SARS-CoV-2 VP enumeration was carried out using reverse transcription quantitative polymerase chain reaction. The VP selection assay successfully identified healthy donors (clinical specificity = 100%) and 19 of 20 patients with coronavirus disease 2019 (COVID-19) (95% sensitivity). In 15 patients with COVID-19, the presence of active SARS-CoV-2 VPs was found. The chip can be reprogrammed for any VP or exosomes by simply changing the affinity agent.
Collapse
Affiliation(s)
- Sachindra S. T. Gamage
- Department of Chemistry, The University of Kansas, Lawrence, KS 66045, USA
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
| | - Thilanga N. Pahattuge
- Department of Chemistry, The University of Kansas, Lawrence, KS 66045, USA
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
| | - Harshani Wijerathne
- Department of Chemistry, The University of Kansas, Lawrence, KS 66045, USA
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
| | - Katie Childers
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
- Bioengineering Program, The University of Kansas, Lawrence, KS 66045, USA
| | - Swarnagowri Vaidyanathan
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
- Bioengineering Program, The University of Kansas, Lawrence, KS 66045, USA
| | - Uditha S. Athapattu
- Department of Chemistry, The University of Kansas, Lawrence, KS 66045, USA
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
| | - Lulu Zhang
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
- Bioengineering Program, The University of Kansas, Lawrence, KS 66045, USA
| | - Zheng Zhao
- Department of Chemistry, The University of Kansas, Lawrence, KS 66045, USA
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
| | | | | | | | | | | | - Brian V. Geisbrecht
- Department of Biochemistry and Molecular Biophysics, Kansas State University, Manhattan, KS 66506, USA
| | - Harsh Pathak
- Department of Pathology and Laboratory Medicine, University of Kansas Medical Center, Kansas City, KS 66160, USA
| | | | - Gregory N. Gan
- Department of Radiation Oncology, University of Kansas Medical Center, Kansas City, KS 66160, USA
- University of Kansas Cancer Center, University of Kansas Medical Center, Kansas City, KS 66160, USA
| | - Junseo Choi
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
- Department of Industrial and Mechanical Engineering, Louisiana State University, Baton Rouge, LA 70803, USA
| | - Sunggook Park
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
- Department of Industrial and Mechanical Engineering, Louisiana State University, Baton Rouge, LA 70803, USA
| | - Andrew K. Godwin
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
- Department of Pathology and Laboratory Medicine, University of Kansas Medical Center, Kansas City, KS 66160, USA
- University of Kansas Cancer Center, University of Kansas Medical Center, Kansas City, KS 66160, USA
| | - Malgorzata A. Witek
- Department of Chemistry, The University of Kansas, Lawrence, KS 66045, USA
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
| | - Steven A. Soper
- Department of Chemistry, The University of Kansas, Lawrence, KS 66045, USA
- Center of BioModular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, KS 66045, USA
- Bioengineering Program, The University of Kansas, Lawrence, KS 66045, USA
- University of Kansas Cancer Center, University of Kansas Medical Center, Kansas City, KS 66160, USA
- Department of Mechanical Engineering, The University of Kansas, Lawrence, KS 66045, USA
| |
Collapse
|
12
|
Nagel AM, Magill M, de Haan HW. Studying first passage problems using neural networks: A case study in the slit-well microfluidic device. Phys Rev E 2022; 106:025311. [PMID: 36109883 DOI: 10.1103/physreve.106.025311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 07/28/2022] [Indexed: 06/15/2023]
Abstract
This study presents deep neural network solutions to a time-integrated Smoluchowski equation modeling the mean first passage time of nanoparticles traversing the slit-well microfluidic device. This physical scenario is representative of a broader class of parametrized first passage problems in which key output metrics are dictated by a complicated interplay of problem parameters and system geometry. Specifically, whereas these types of problems are commonly studied using particle simulations of stochastic differential equation models, here the corresponding partial differential equation model is solved using a method based on deep neural networks. The results illustrate that the neural network method is synergistic with the time-integrated Smoluchowski model: together, these are used to construct continuous mappings from key physical inputs (applied voltage and particle diameter) to key output metrics (mean first passage time and effective mobility). In particular, this capability is a unique advantage of the time-integrated Smoluchowski model over the corresponding stochastic differential equation models. Furthermore, the neural network method is demonstrated to easily and reliably handle geometry-modifying parameters, which is generally difficult to accomplish using other methods.
Collapse
Affiliation(s)
- Andrew M Nagel
- Faculty of Science, University of Ontario Institute of Technology, 2000 Simcoe St N, Oshawa, Ontario, Canada L1H7K4
| | - Martin Magill
- Faculty of Science, University of Ontario Institute of Technology, 2000 Simcoe St N, Oshawa, Ontario, Canada L1H7K4
| | - Hendrick W de Haan
- Faculty of Science, University of Ontario Institute of Technology, 2000 Simcoe St N, Oshawa, Ontario, Canada L1H7K4
| |
Collapse
|
13
|
Pandey SK, Mohanta GC, Kumar V, Gupta K. Diagnostic Tools for Rapid Screening and Detection of SARS-CoV-2 Infection. Vaccines (Basel) 2022; 10:1200. [PMID: 36016088 PMCID: PMC9414050 DOI: 10.3390/vaccines10081200] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 07/19/2022] [Accepted: 07/25/2022] [Indexed: 12/11/2022] Open
Abstract
The novel coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has severely impacted human health and the health management system globally. The ongoing pandemic has required the development of more effective diagnostic strategies for restricting deadly disease. For appropriate disease management, accurate and rapid screening and isolation of the affected population is an efficient means of containment and the decimation of the disease. Therefore, considerable efforts are being directed toward the development of rapid and robust diagnostic techniques for respiratory infections, including SARS-CoV-2. In this article, we have summarized the origin, transmission, and various diagnostic techniques utilized for the detection of the SARS-CoV-2 virus. These higher-end techniques can also detect the virus copy number in asymptomatic samples. Furthermore, emerging rapid, cost-effective, and point-of-care diagnostic devices capable of large-scale population screening for COVID-19 are discussed. Finally, some breakthrough developments based on spectroscopic diagnosis that could revolutionize the field of rapid diagnosis are discussed.
Collapse
Affiliation(s)
- Satish Kumar Pandey
- Department of Biotechnology, School of Life Sciences, Mizoram University (Central University), Aizawl 796004, India
| | - Girish C. Mohanta
- Materials Science and Sensor Applications, CSIR-Central Scientific Instruments Organisation (CSIR-CSIO), Chandigarh 160030, India;
| | - Vinod Kumar
- Department of Dermatology, Venerology and Leprology, Post Graduate Institute of Medical Education & Research, Chandigarh 160012, India;
| | - Kuldeep Gupta
- Russel H. Morgan, Department of Radiology and Radiological Sciences, School of Medicine, Johns Hopkins University, Baltimore, MD 21287, USA
| |
Collapse
|
14
|
Koyilot MC, Natarajan P, Hunt CR, Sivarajkumar S, Roy R, Joglekar S, Pandita S, Tong CW, Marakkar S, Subramanian L, Yadav SS, Cherian AV, Pandita TK, Shameer K, Yadav KK. Breakthroughs and Applications of Organ-on-a-Chip Technology. Cells 2022; 11:cells11111828. [PMID: 35681523 PMCID: PMC9180073 DOI: 10.3390/cells11111828] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 05/28/2022] [Accepted: 05/30/2022] [Indexed: 12/10/2022] Open
Abstract
Organ-on-a-chip (OOAC) is an emerging technology based on microfluid platforms and in vitro cell culture that has a promising future in the healthcare industry. The numerous advantages of OOAC over conventional systems make it highly popular. The chip is an innovative combination of novel technologies, including lab-on-a-chip, microfluidics, biomaterials, and tissue engineering. This paper begins by analyzing the need for the development of OOAC followed by a brief introduction to the technology. Later sections discuss and review the various types of OOACs and the fabrication materials used. The implementation of artificial intelligence in the system makes it more advanced, thereby helping to provide a more accurate diagnosis as well as convenient data management. We introduce selected OOAC projects, including applications to organ/disease modelling, pharmacology, personalized medicine, and dentistry. Finally, we point out certain challenges that need to be surmounted in order to further develop and upgrade the current systems.
Collapse
Affiliation(s)
- Mufeeda C. Koyilot
- Molecular Robotics, Cochin 682033, India; (M.C.K.); (P.N.); (S.S.); (R.R.); (S.J.); (S.M.); (A.V.C.)
| | - Priyadarshini Natarajan
- Molecular Robotics, Cochin 682033, India; (M.C.K.); (P.N.); (S.S.); (R.R.); (S.J.); (S.M.); (A.V.C.)
| | - Clayton R. Hunt
- Houston Methodist Research Institute, Houston, TX 77030, USA;
| | - Sonish Sivarajkumar
- Molecular Robotics, Cochin 682033, India; (M.C.K.); (P.N.); (S.S.); (R.R.); (S.J.); (S.M.); (A.V.C.)
| | - Romy Roy
- Molecular Robotics, Cochin 682033, India; (M.C.K.); (P.N.); (S.S.); (R.R.); (S.J.); (S.M.); (A.V.C.)
| | - Shreeram Joglekar
- Molecular Robotics, Cochin 682033, India; (M.C.K.); (P.N.); (S.S.); (R.R.); (S.J.); (S.M.); (A.V.C.)
| | - Shruti Pandita
- Mays Cancer Center, University of Texas Health Sciences Center at San Antonio, San Antonio, TX 78229, USA;
| | - Carl W. Tong
- School of Engineering Medicine, Texas A&M University, Houston, TX 77030, USA;
| | - Shamsudheen Marakkar
- Molecular Robotics, Cochin 682033, India; (M.C.K.); (P.N.); (S.S.); (R.R.); (S.J.); (S.M.); (A.V.C.)
| | | | - Shalini S. Yadav
- Department of Immunology, UT MD Anderson Cancer Center, Houston, TX 77030, USA;
| | - Anoop V. Cherian
- Molecular Robotics, Cochin 682033, India; (M.C.K.); (P.N.); (S.S.); (R.R.); (S.J.); (S.M.); (A.V.C.)
| | - Tej K. Pandita
- Houston Methodist Research Institute, Houston, TX 77030, USA;
- Center for Genomic and Precision Medicine, Institute of Biosciences and Technology, Department of Translational Medical Sciences, Texas A&M University, Houston, TX 77030, USA
- Correspondence: (T.K.P.); (K.S.); (K.K.Y.)
| | - Khader Shameer
- School of Public Health, Faculty of Medicine, Imperial College London, South Kensington, London SW7 2AZ, UK
- Correspondence: (T.K.P.); (K.S.); (K.K.Y.)
| | - Kamlesh K. Yadav
- School of Engineering Medicine, Texas A&M University, Houston, TX 77030, USA;
- Center for Genomic and Precision Medicine, Institute of Biosciences and Technology, Department of Translational Medical Sciences, Texas A&M University, Houston, TX 77030, USA
- Correspondence: (T.K.P.); (K.S.); (K.K.Y.)
| |
Collapse
|
15
|
Harun-Ur-Rashid M, Foyez T, Jahan I, Pal K, Imran AB. Rapid diagnosis of COVID-19 via nano-biosensor-implemented biomedical utilization: a systematic review. RSC Adv 2022; 12:9445-9465. [PMID: 35424900 PMCID: PMC8959446 DOI: 10.1039/d2ra01293f] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 03/04/2022] [Indexed: 12/14/2022] Open
Abstract
The novel human coronavirus pandemic is one of the most significant occurrences in human civilization. The rapid proliferation and mutation of Severe Acute Respiratory Syndrome-Coronavirus 2 (SARS-CoV-2) have created an exceedingly challenging situation throughout the world's healthcare systems ranging from underdeveloped countries to super-developed countries. The disease is generally recognized as coronavirus disease 2019 (COVID-19), and it is caused by a new human CoV, which has put mankind in jeopardy. COVID-19 is death-dealing and affects people of all ages, including the elderly and middle-aged people, children, infants, persons with co-morbidities, and immunocompromised patients. Moreover, multiple SARS-CoV-2 variants have evolved as a result of genetic alteration. Some variants cause severe symptoms in patients, while others cause an unusually high infection rate, and yet others cause extremely severe symptoms as well as a high infection rate. Contrasting with a previous epidemic, COVID-19 is more contagious since the spike protein of SARS-CoV-2 demonstrates profuse affection to angiotensin-converting enzyme II (ACE2) that is copiously expressed on the surface of human lung cells. Since the estimation and tracking of viral loads are essential for determining the infection stage and recovery duration, a quick, accurate, easy, cheap, and versatile diagnostic tool is critical for managing COVID-19, as well as for outbreak control. Currently, Reverse Transcription Polymerase Chain Reaction (RT-PCR) testing is the most often utilized approach for COVID-19 diagnosis, while Computed Tomography (CT) scans of the chest are used to assess the disease's stages. However, the RT-PCR method is non-portable, tedious, and laborious, and the latter is not capable of detecting the preliminary stage of infection. In these circumstances, nano-biosensors can play an important role to deliver point-of-care diagnosis for a variety of disorders including a wide variety of viral infections rapidly, economically, precisely, and accurately. New technologies are being developed to overcome the drawbacks of the current methods. Nano-biosensors comprise bioreceptors with electrochemical, optical, or FET-based transduction for the specific detection of biomarkers. Different types of organic-inorganic nanomaterials have been incorporated for designing, fabricating, and improving the performance and analytical ability of sensors by increasing sensitivity, adsorption, and biocompatibility. The particular focus of this review is to carry out a systematic study of the status and perspectives of synthetic routes for nano-biosensors, including their background, composition, fabrication processes, and prospective applications in the diagnosis of COVID-19.
Collapse
Affiliation(s)
- Mohammad Harun-Ur-Rashid
- Department of Chemistry, International University of Business Agriculture and Technology Dhaka 1230 Bangladesh
| | - Tahmina Foyez
- Department of Pharmaceutical Sciences, School of Health and Life Sciences, North South University Dhaka 1229 Bangladesh
| | - Israt Jahan
- Department of Cell Physiology, Graduate School of Medicine, Nagoya University Nagoya Japan
| | - Kaushik Pal
- University Centre for Research and Development (UCRD), Department of Physics, Chandigarh University Punjab 140413 India
| | - Abu Bin Imran
- Department of Chemistry, Bangladesh University of Engineering and Technology Dhaka 1000 Bangladesh
| |
Collapse
|
16
|
Lin Z, Dai C, Cho JH. Realization of Curved Circular Nanotubes Using In Situ Monitored Self-Assembly. NANO LETTERS 2022; 22:2140-2146. [PMID: 35050632 DOI: 10.1021/acs.nanolett.1c04093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Curved fluidic channels with a circular cross-section play an important role in biology, chemistry, and medicine. However, in nanofluidics, a problem that is largely unsolved is the lack of an effective fabrication method for curved circular nanotubes (10-1000 nm). In this work, an electron-beam-induced self-assembly process was applied to achieve fine curved nanostructures for the realization of nanofluidic devices. The diameter of the tube could be precisely controlled by an atomic layer deposition process. Fluid transported through the nanochannels was verified and characterized using a dark-field microscope under an optical diffraction limit size. The fluid flow demonstrates that the liquid's evaporation (vapor diffusion) in the nanochannel generates compressed vapor, which pumps the liquid and pushes it forward, resulting in a directional flow behavior in the ∼100 nm radius of tubes. This phenomenon could provide a useful platform for the development of diverse nanofluidic devices.
Collapse
Affiliation(s)
- Zihao Lin
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Chunhui Dai
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Jeong-Hyun Cho
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
17
|
Amarasekara H, Oshaben KM, Jeans KB, Sangsari PR, Morgan NY, O’Farrell B, Appella DH. Cyclopentane peptide nucleic acid: Gold nanoparticle conjugates for the detection of nucleic acids in a microfluidic format. Biopolymers 2022; 113:e23481. [PMID: 34812507 PMCID: PMC8957522 DOI: 10.1002/bip.23481] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 10/19/2021] [Accepted: 10/25/2021] [Indexed: 11/06/2022]
Abstract
Routine patient testing for viral infections is critical to identify infected individuals for treatment and to prevent spreading of infections to others. Developing robust and reliable diagnostic tools to detect nucleic acids of viruses at the point-of-care could greatly assist the clinical management of viral infections. The remarkable stability and high binding affinity of peptide nucleic acids (PNAs) to target nucleic acids could make PNA-based biosensors an excellent starting point to develop new nucleic acid detection technologies. We report the application of cyclopentane-modified PNAs to capture target nucleic acids in a microfluidic channel, and the use of bioorthogonal PNAs conjugated to gold nanoparticles as probes to semi-quantitatively signal the presence of a target nucleic acid derived from HIV-1. The basic results presented could be used to develop more advanced devices to detect nucleic acids from viruses such as HIV, SARS-CoV-2, and a wide range of other human diseases.
Collapse
Affiliation(s)
- Harsha Amarasekara
- Synthetic Bioactive Molecules Section, Laboratory of Bioorganic Chemistry (LBC), National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, 8 Center Drive, Room 404, Bethesda, MD 20892, USA
| | - Kaylyn M. Oshaben
- Synthetic Bioactive Molecules Section, Laboratory of Bioorganic Chemistry (LBC), National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, 8 Center Drive, Room 404, Bethesda, MD 20892, USA,Altratech Ltd., Forge House, Forge Hill, Cork, T12 F867, Ireland
| | - Kendra B. Jeans
- Synthetic Bioactive Molecules Section, Laboratory of Bioorganic Chemistry (LBC), National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, 8 Center Drive, Room 404, Bethesda, MD 20892, USA
| | - Paniz Rezvan Sangsari
- Biomedical Engineering and Physical Science Shared Resource, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
| | - Nicole Y. Morgan
- Biomedical Engineering and Physical Science Shared Resource, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
| | - Brian O’Farrell
- Altratech Ltd., Forge House, Forge Hill, Cork, T12 F867, Ireland
| | - Daniel H. Appella
- Synthetic Bioactive Molecules Section, Laboratory of Bioorganic Chemistry (LBC), National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, 8 Center Drive, Room 404, Bethesda, MD 20892, USA
| |
Collapse
|
18
|
Xu J, Suo W, Goulev Y, Sun L, Kerr L, Paulsson J, Zhang Y, Lao T. Handheld Microfluidic Filtration Platform Enables Rapid, Low-Cost, and Robust Self-Testing of SARS-CoV-2 Virus. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2104009. [PMID: 34845827 PMCID: PMC8725168 DOI: 10.1002/smll.202104009] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Revised: 10/27/2021] [Indexed: 05/17/2023]
Abstract
Here, a novel microfluidic test kit combining ultrahigh throughput hydrodynamic filtration and sandwich immunoassay is reported. Specifically, nano and microbeads coated with two different, noncompetitive antibodies, are used to capture the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid (N) proteins simultaneously, forming larger complexes. Microfluidic filtration discards free nanobeads but retains antigen-bridged complexes in the observation zone, where a display of red color indicates the presence of antigen in the sample. This testing platform exhibits high throughput separation (<30 s) and enrichment of antigen that exceeds the traditional lateral flow assays or microfluidic assays, with a low limit of detection (LoD) < 100 copies mL-1 . In two rounds of clinical trials conducted in December 2020 and August 2021, the assays demonstrate high sensitivities of 95.4% and 100%, respectively, which proves this microfluidic test kit is capable of detecting SARS-CoV-2 virus variants evolved over significant periods of time. Furthermore, the mass-produced chip can be fabricated at a cost of $0.98/test and the robust design allows the chip to be reused for over 50 times. All of these features make the microfluidic test kit particularly suitable for areas with inadequate medical infrastructure and a shortage of laboratory resources.
Collapse
Affiliation(s)
- Jiang Xu
- Department of Systems Biology, Blavatnik Institute, Harvard Medical School, Boston, MA, 02115, USA
| | - Wenhao Suo
- Department of Pathology, The First Affiliated Hospital of Xiamen University, 55 Zhenhai Road, Xiamen, 361003, China
- Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA 02215, USA
| | - Youlian Goulev
- Department of Systems Biology, Blavatnik Institute, Harvard Medical School, Boston, MA, 02115, USA
| | - Lei Sun
- Department of Systems Biology, Blavatnik Institute, Harvard Medical School, Boston, MA, 02115, USA
| | - Liam Kerr
- Department of Mechanical Engineering, Center for Intelligent Machines, McGill University, Montreal, QC, H3A0C3, Canada
| | - Johan Paulsson
- Department of Systems Biology, Blavatnik Institute, Harvard Medical School, Boston, MA, 02115, USA
| | - Yan Zhang
- Tianjin Key Laboratory for Modern Drug Delivery and High-Efficiency, Collaborative Innovation Center of Chemical Science and Engineering, School of Pharmaceutical Science and Technology, Tianjin University, Tianjin, 300072, China
- Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin, 300072, China
| | - Taotao Lao
- Boston Molecules Inc., 564 Main Street, Waltham, MA 02452, USA
- Center for Immunology and Inflammatory Diseases, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA, 02114, USA
| |
Collapse
|
19
|
Iliescu FS, Ionescu AM, Gogianu L, Simion M, Dediu V, Chifiriuc MC, Pircalabioru GG, Iliescu C. Point-of-Care Testing-The Key in the Battle against SARS-CoV-2 Pandemic. MICROMACHINES 2021; 12:1464. [PMID: 34945314 PMCID: PMC8708595 DOI: 10.3390/mi12121464] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 11/24/2021] [Accepted: 11/25/2021] [Indexed: 12/11/2022]
Abstract
The deleterious effects of the coronavirus disease 2019 (COVID-19) pandemic urged the development of diagnostic tools to manage the spread of disease. Currently, the "gold standard" involves the use of quantitative real-time polymerase chain reaction (qRT-PCR) for SARS-CoV-2 detection. Even though it is sensitive, specific and applicable for large batches of samples, qRT-PCR is labour-intensive, time-consuming, requires trained personnel and is not available in remote settings. This review summarizes and compares the available strategies for COVID-19: serological testing, Point-of-Care Testing, nanotechnology-based approaches and biosensors. Last but not least, we address the advantages and limitations of these methods as well as perspectives in COVID-19 diagnostics. The effort is constantly focused on understanding the quickly changing landscape of available diagnostic testing of COVID-19 at the clinical levels and introducing reliable and rapid screening point of care testing. The last approach is key to aid the clinical decision-making process for infection control, enhancing an appropriate treatment strategy and prompt isolation of asymptomatic/mild cases. As a viable alternative, Point-of-Care Testing (POCT) is typically low-cost and user-friendly, hence harbouring tremendous potential for rapid COVID-19 diagnosis.
Collapse
Affiliation(s)
- Florina Silvia Iliescu
- National Institute for Research and Development in Microtechnologies, IMT-Bucharest, 077190 Bucharest, Romania; (F.S.I.); (A.M.I.); (L.G.); (M.S.); (V.D.)
| | - Ana Maria Ionescu
- National Institute for Research and Development in Microtechnologies, IMT-Bucharest, 077190 Bucharest, Romania; (F.S.I.); (A.M.I.); (L.G.); (M.S.); (V.D.)
- Department of Biochemical Engineering, University College London, Bernard Katz Building, London WC1E 6BT, UK
| | - Larisa Gogianu
- National Institute for Research and Development in Microtechnologies, IMT-Bucharest, 077190 Bucharest, Romania; (F.S.I.); (A.M.I.); (L.G.); (M.S.); (V.D.)
| | - Monica Simion
- National Institute for Research and Development in Microtechnologies, IMT-Bucharest, 077190 Bucharest, Romania; (F.S.I.); (A.M.I.); (L.G.); (M.S.); (V.D.)
| | - Violeta Dediu
- National Institute for Research and Development in Microtechnologies, IMT-Bucharest, 077190 Bucharest, Romania; (F.S.I.); (A.M.I.); (L.G.); (M.S.); (V.D.)
| | - Mariana Carmen Chifiriuc
- Research Institute of University of Bucharest, University of Bucharest, 050095 Bucharest, Romania;
- The Romanian Academy, 25, Calea Victoriei, Sector 1, 010071 Bucharest, Romania
| | | | - Ciprian Iliescu
- National Institute for Research and Development in Microtechnologies, IMT-Bucharest, 077190 Bucharest, Romania; (F.S.I.); (A.M.I.); (L.G.); (M.S.); (V.D.)
- Academy of Romanian Scientists, 010071 Bucharest, Romania
- Faculty of Applied Chemistry and Material Science, University “Politehnica” of Bucharest, 011061 Bucharest, Romania
| |
Collapse
|
20
|
Isothermal Recombinase Polymerase Amplification (RPA) of E. coli gDNA in Commercially Fabricated PCB-Based Microfluidic Platforms. MICROMACHINES 2021; 12:mi12111387. [PMID: 34832799 PMCID: PMC8619769 DOI: 10.3390/mi12111387] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2021] [Revised: 11/04/2021] [Accepted: 11/10/2021] [Indexed: 12/04/2022]
Abstract
Printed circuit board (PCB) technology has been recently proposed as a convenient platform for seamlessly integrating electronics and microfluidics in the same substrate, thus facilitating the introduction of integrated and low-cost microfluidic devices to the market, thanks to the inherent upscaling potential of the PCB industry. Herein, a microfluidic chip, encompassing on PCB both a meandering microchannel and microheaters to accommodate recombinase polymerase amplification (RPA), is designed and commercially fabricated for the first time on PCB. The developed microchip is validated for RPA-based amplification of two E. coli target genes compared to a conventional thermocycler. The RPA performance of the PCB microchip was found to be well-comparable to that of a thermocycler yet with a remarkably lower power consumption (0.6 W). This microchip is intended for seamless integration with biosensors in the same PCB substrate for the development of a point-of-care (POC) molecular diagnostics platform.
Collapse
|
21
|
Escobar A, Chiu P, Qu J, Zhang Y, Xu CQ. Integrated Microfluidic-Based Platforms for On-Site Detection and Quantification of Infectious Pathogens: Towards On-Site Medical Translation of SARS-CoV-2 Diagnostic Platforms. MICROMACHINES 2021; 12:1079. [PMID: 34577722 PMCID: PMC8470930 DOI: 10.3390/mi12091079] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 08/26/2021] [Accepted: 08/30/2021] [Indexed: 12/18/2022]
Abstract
The rapid detection and quantification of infectious pathogens is an essential component to the control of potentially lethal outbreaks among human populations worldwide. Several of these highly infectious pathogens, such as Middle East respiratory syndrome (MERS) and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), have been cemented in human history as causing epidemics or pandemics due to their lethality and contagiousness. SARS-CoV-2 is an example of these highly infectious pathogens that have recently become one of the leading causes of globally reported deaths, creating one of the worst economic downturns and health crises in the last century. As a result, the necessity for highly accurate and increasingly rapid on-site diagnostic platforms for highly infectious pathogens, such as SARS-CoV-2, has grown dramatically over the last two years. Current conventional non-microfluidic diagnostic techniques have limitations in their effectiveness as on-site devices due to their large turnaround times, operational costs and the need for laboratory equipment. In this review, we first present criteria, both novel and previously determined, as a foundation for the development of effective and viable on-site microfluidic diagnostic platforms for several notable pathogens, including SARS-CoV-2. This list of criteria includes standards that were set out by the WHO, as well as our own "seven pillars" for effective microfluidic integration. We then evaluate the use of microfluidic integration to improve upon currently, and previously, existing platforms for the detection of infectious pathogens. Finally, we discuss a stage-wise means to translate our findings into a fundamental framework towards the development of more effective on-site SARS-CoV-2 microfluidic-integrated platforms that may facilitate future pandemic diagnostic and research endeavors. Through microfluidic integration, many limitations in currently existing infectious pathogen diagnostic platforms can be eliminated or improved upon.
Collapse
Affiliation(s)
- Andres Escobar
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada; (A.E.); (J.Q.); (Y.Z.)
| | - Phyllis Chiu
- Department of Engineering Physics, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada;
| | - Jianxi Qu
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada; (A.E.); (J.Q.); (Y.Z.)
| | - Yushan Zhang
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada; (A.E.); (J.Q.); (Y.Z.)
| | - Chang-qing Xu
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada; (A.E.); (J.Q.); (Y.Z.)
- Department of Engineering Physics, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada;
| |
Collapse
|
22
|
Duzagac F, Saorin G, Memeo L, Canzonieri V, Rizzolio F. Microfluidic Organoids-on-a-Chip: Quantum Leap in Cancer Research. Cancers (Basel) 2021; 13:737. [PMID: 33578886 PMCID: PMC7916612 DOI: 10.3390/cancers13040737] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 01/24/2021] [Accepted: 01/29/2021] [Indexed: 02/06/2023] Open
Abstract
Organ-like cell clusters, so-called organoids, which exhibit self-organized and similar organ functionality as the tissue of origin, have provided a whole new level of bioinspiration for ex vivo systems. Microfluidic organoid or organs-on-a-chip platforms are a new group of micro-engineered promising models that recapitulate 3D tissue structure and physiology and combines several advantages of current in vivo and in vitro models. Microfluidics technology is used in numerous applications since it allows us to control and manipulate fluid flows with a high degree of accuracy. This system is an emerging tool for understanding disease development and progression, especially for personalized therapeutic strategies for cancer treatment, which provide well-grounded, cost-effective, powerful, fast, and reproducible results. In this review, we highlight how the organoid-on-a-chip models have improved the potential of efficiency and reproducibility of organoid cultures. More widely, we discuss current challenges and development on organoid culture systems together with microfluidic approaches and their limitations. Finally, we describe the recent progress and potential utilization in the organs-on-a-chip practice.
Collapse
Affiliation(s)
- Fahriye Duzagac
- Department of Molecular Sciences and Nanosystems, Ca’ Foscari University of Venice, 30123 Venezia, Italy; (F.D.); (G.S.)
| | - Gloria Saorin
- Department of Molecular Sciences and Nanosystems, Ca’ Foscari University of Venice, 30123 Venezia, Italy; (F.D.); (G.S.)
| | - Lorenzo Memeo
- Department of Experimental Oncology, Mediterranean Institute of Oncology (IOM), 95029 Catania, Italy;
| | - Vincenzo Canzonieri
- Pathology Unit, Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, 33081 Aviano, Italy;
- Department of Medical, Surgical and Health Sciences, University of Trieste, 34127 Trieste, Italy
| | - Flavio Rizzolio
- Department of Molecular Sciences and Nanosystems, Ca’ Foscari University of Venice, 30123 Venezia, Italy; (F.D.); (G.S.)
- Pathology Unit, Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, 33081 Aviano, Italy;
| |
Collapse
|
23
|
Şahin S, Ünlü C, Trabzon L. Affinity biosensors developed with quantum dots in microfluidic systems. EMERGENT MATERIALS 2021; 4:187-209. [PMID: 33718778 PMCID: PMC7944724 DOI: 10.1007/s42247-021-00195-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 02/18/2021] [Indexed: 04/14/2023]
Abstract
Quantum dots (QDs) are synthetic semiconductor nanocrystals with unique optical and electronic properties due to their size (2-10 nm) such as high molar absorption coefficient (10-100 times higher than organic dyes), resistance to chemical degradation, and unique optoelectronic properties due to quantum confinement (high quantum yield, emission color change with size). Compared to organic fluorophores, the narrower emission band and wider absorption bands of QDs offer great advantages in cell imaging and biosensor applications. The optoelectronic features of QDs have prompted their intensive use in bioanalytical, biophysical, and biomedical research. As the nanomaterials have been integrated into microfluidic systems, microfluidic technology has accelerated the adaptation of nanomaterials to clinical evaluation together with the advantages such as being more economical, more reproducible, and more susceptible to modification and integration with other technologies. Microfluidic systems serve an important role by being a platform in which QDs are integrated for biosensing applications. As we combine the advantages of QDs and microfluidic technology for biosensing technology, QD-based biosensor integrated with microfluidic systems can be used as an advanced and versatile diagnostic technology in case of pandemic. Specifically, there is an urgent necessity to have reliable and fast detection systems for COVID-19 virus. In this review, affinity-based biosensing mechanisms which are developed with QDs are examined in the domain of microfluidic approach. The combination of microfluidic technology and QD-based affinity biosensors are presented with examples in order to develop a better technological framework of diagnostic for COVID-19 virus.
Collapse
Affiliation(s)
- Sultan Şahin
- Nanosicence and Nanoengineering Department, Istanbul Technical University, Istanbul, Turkey
- Nanotechnology Research and Application Center – ITUnano, Istanbul Technical University, Istanbul, Turkey
- MEMS Research Center, Istanbul Technical University, Istanbul, Turkey
| | - Caner Ünlü
- Nanosicence and Nanoengineering Department, Istanbul Technical University, Istanbul, Turkey
- Nanotechnology Research and Application Center – ITUnano, Istanbul Technical University, Istanbul, Turkey
- Department of Chemistry, Istanbul Technical University, Istanbul, Turkey
| | - Levent Trabzon
- Nanosicence and Nanoengineering Department, Istanbul Technical University, Istanbul, Turkey
- Nanotechnology Research and Application Center – ITUnano, Istanbul Technical University, Istanbul, Turkey
- MEMS Research Center, Istanbul Technical University, Istanbul, Turkey
- Faculty of Mechanical Engineering, Istanbul Technical University, Istanbul, Turkey
| |
Collapse
|
24
|
Sun Y, Ho M. Emerging antibody-based therapeutics against SARS-CoV-2 during the global pandemic. Antib Ther 2020; 3:246-256. [PMID: 33912795 PMCID: PMC7717131 DOI: 10.1093/abt/tbaa025] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/13/2020] [Accepted: 11/14/2020] [Indexed: 12/20/2022] Open
Abstract
SARS-CoV-2 antibody therapeutics are being evaluated in clinical and preclinical stages. As of 11 October 2020, 13 human monoclonal antibodies targeting the SARS-CoV-2 spike protein have entered clinical trials with three (REGN-COV2, LY3819253/LY-CoV555, and VIR-7831/VIR-7832) in phase 3. On 9 November 2020, the US Food and Drug Administration issued an emergency use authorization for bamlanivimab (LY3819253/LY-CoV555) for the treatment of mild-to-moderate COVID-19. This review outlines the development of neutralizing antibodies against SARS-CoV-2, with a focus on discussing various antibody discovery strategies (animal immunization, phage display and B cell cloning), describing binding epitopes and comparing neutralizing activities. Broad-neutralizing antibodies targeting the spike proteins of SARS-CoV-2 and SARS-CoV might be helpful for treating COVID-19 and future infections. VIR-7831/7832 based on S309 is the only antibody in late clinical development, which can neutralize both SARS-CoV-2 and SARS-CoV although it does not directly block virus receptor binding. Thus far, the only cross-neutralizing antibody that is also a receptor binding blocker is nanobody VHH-72. The feasibility of developing nanobodies as inhaled drugs for treating COVID-19 and other respiratory diseases is an attractive idea that is worth exploring and testing. A cocktail strategy such as REGN-COV2, or engineered multivalent and multispecific molecules, combining two or more antibodies might improve the efficacy and protect against resistance due to virus escape mutants. Besides the receptor-binding domain, other viral antigens such as the S2 subunit of the spike protein and the viral attachment sites such as heparan sulfate proteoglycans that are on the host cells are worth investigating.
Collapse
Affiliation(s)
- Yaping Sun
- Antibody Engineering Program, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892, USA
| | - Mitchell Ho
- Antibody Engineering Program, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892, USA
- Laboratory of Molecular Biology, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892, USA
| |
Collapse
|