1
|
Wang Y, Yang X, Zhang X, Wang Y, Pei W. Implantable intracortical microelectrodes: reviewing the present with a focus on the future. MICROSYSTEMS & NANOENGINEERING 2023; 9:7. [PMID: 36620394 PMCID: PMC9814492 DOI: 10.1038/s41378-022-00451-6] [Citation(s) in RCA: 21] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Revised: 08/08/2022] [Accepted: 08/22/2022] [Indexed: 06/17/2023]
Abstract
Implantable intracortical microelectrodes can record a neuron's rapidly changing action potentials (spikes). In vivo neural activity recording methods often have either high temporal or spatial resolution, but not both. There is an increasing need to record more neurons over a longer duration in vivo. However, there remain many challenges to overcome before achieving long-term, stable, high-quality recordings and realizing comprehensive, accurate brain activity analysis. Based on the vision of an idealized implantable microelectrode device, the performance requirements for microelectrodes are divided into four aspects, including recording quality, recording stability, recording throughput, and multifunctionality, which are presented in order of importance. The challenges and current possible solutions for implantable microelectrodes are given from the perspective of each aspect. The current developments in microelectrode technology are analyzed and summarized.
Collapse
Affiliation(s)
- Yang Wang
- State Key Laboratory of Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, 100083 Beijing, China
- University of Chinese Academy of Sciences, 100049 Beijing, China
| | - Xinze Yang
- State Key Laboratory of Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, 100083 Beijing, China
- University of Chinese Academy of Sciences, 100049 Beijing, China
| | - Xiwen Zhang
- State Key Laboratory of Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, 100083 Beijing, China
- University of Chinese Academy of Sciences, 100049 Beijing, China
| | - Yijun Wang
- State Key Laboratory of Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, 100083 Beijing, China
- University of Chinese Academy of Sciences, 100049 Beijing, China
- Chinese Institute for Brain Research, 102206 Beijing, China
| | - Weihua Pei
- State Key Laboratory of Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, 100083 Beijing, China
- University of Chinese Academy of Sciences, 100049 Beijing, China
| |
Collapse
|
2
|
Abstract
OBJECTIVE This study analyzes the peak resistance frequency (PRF) method described by Mercanzini et al., a method that can easily extract the tissue resistance from impedance spectroscopy for many neural engineering applications but has no analytical description thus far. METHODS Mathematical analyses and computer simulations were used to explore underlying principles, accuracy, and limitations of the PRF method. RESULTS The mathematical analyses demonstrated that the PRF method has an inherent but correctable deviation dependent on the idealness of the electrode-tissue interface, which is validated by simulations. Further simulations show that both frequency sampling and noise affect the accuracy of the PRF method, and in general, it performs less accurately than least squares methods. However, the PRF method achieves simplicity and reduced measurement and computation time at the expense of accuracy. CONCLUSION From the qualitative results, the PRF method can work with reasonable precision and simplicity, although its limitation and the idealness of the electrode-tissue interface involved should be taken into consideration. SIGNIFICANCE This paper provides a mathematical foundation for the PRF method and its practical implementation.
Collapse
|
3
|
Fattahi P, Yang G, Kim G, Abidian MR. A review of organic and inorganic biomaterials for neural interfaces. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2014; 26:1846-85. [PMID: 24677434 PMCID: PMC4373558 DOI: 10.1002/adma.201304496] [Citation(s) in RCA: 300] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2013] [Revised: 10/08/2013] [Indexed: 05/18/2023]
Abstract
Recent advances in nanotechnology have generated wide interest in applying nanomaterials for neural prostheses. An ideal neural interface should create seamless integration into the nervous system and performs reliably for long periods of time. As a result, many nanoscale materials not originally developed for neural interfaces become attractive candidates to detect neural signals and stimulate neurons. In this comprehensive review, an overview of state-of-the-art microelectrode technologies provided fi rst, with focus on the material properties of these microdevices. The advancements in electro active nanomaterials are then reviewed, including conducting polymers, carbon nanotubes, graphene, silicon nanowires, and hybrid organic-inorganic nanomaterials, for neural recording, stimulation, and growth. Finally, technical and scientific challenges are discussed regarding biocompatibility, mechanical mismatch, and electrical properties faced by these nanomaterials for the development of long-lasting functional neural interfaces.
Collapse
Affiliation(s)
- Pouria Fattahi
- Biomedical Engineering Department and Chemical Engineering Departments, Pennsylvania State University, University Park, PA, 16802, USA
| | - Guang Yang
- Biomedical Engineering Department, Pennsylvania State University, University Park, PA, 16802, USA
| | - Gloria Kim
- Biomedical Engineering Department, Pennsylvania State University, University Park, PA, 16802, USA
| | - Mohammad Reza Abidian
- Biomedical Engineering Department, Materials Science & Engineering Department, Chemical Engineering Department, Materials Research Institute, Huck Institutes of the Life Sciences, Pennsylvania State University, University Park, PA, 16802, USA
| |
Collapse
|
4
|
|
5
|
McCarthy PT, Rao MP, Otto KJ. Simultaneous recording of rat auditory cortex and thalamus via a titanium-based, microfabricated, microelectrode device. J Neural Eng 2011; 8:046007. [PMID: 21628772 PMCID: PMC3158991 DOI: 10.1088/1741-2560/8/4/046007] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Direct recording from sequential processing stations within the brain has provided opportunity for enhancing understanding of important neural circuits, such as the corticothalamic loops underlying auditory, visual, and somatosensory processing. However, the common reliance upon microwire-based electrodes to perform such recordings often necessitates complex surgeries and increases trauma to neural tissues. This paper reports the development of titanium-based, microfabricated, microelectrode devices designed to address these limitations by allowing acute recording from the thalamic nuclei and associated cortical sites simultaneously in a minimally invasive manner. In particular, devices were designed to simultaneously probe rat auditory cortex and auditory thalamus, with the intent of recording auditory response latencies and isolated action potentials within the separate anatomical sites. Details regarding the design, fabrication, and characterization of these devices are presented, as are preliminary results from acute in vivo recording.
Collapse
Affiliation(s)
- P T McCarthy
- Department of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
| | | | | |
Collapse
|
6
|
Fung AO, Tsiokos C, Paydar O, Chen LH, Jin S, Wang Y, Judy JW. Electrochemical properties and myocyte interaction of carbon nanotube microelectrodes. NANO LETTERS 2010; 10:4321-7. [PMID: 20954739 DOI: 10.1021/nl1013986] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Arrays of carbon nanotube (CNT) microelectrodes (nominal geometric surface areas 20-200 μm(2)) were fabricated by photolithography with chemical vapor deposition of randomly oriented CNTs. Raman spectroscopy showed strong peak intensities in both G and D bands (G/D = 0.86), indicative of significant disorder in the graphitic layers of the randomly oriented CNTs. The impedance spectra of gold and CNT microelectrodes were compared using equivalent circuit models. Compared to planar gold surfaces, pristine nanotubes lowered the overall electrode impedance at 1 kHz by 75%, while nanotubes treated in O(2) plasma reduced the impedance by 95%. Cyclic voltammetry in potassium ferricyanide showed potential peak separations of 133 and 198 mV for gold and carbon nanotube electrodes, respectively. The interaction of cultured cardiac myocytes with randomly oriented and vertically aligned CNTs was investigated by the sectioning of myocytes using focused-ion-beam milling. Vertically aligned nanotubes deposited by plasma-enhanced chemical vapor deposition (PECVD) were observed to penetrate the membrane of neonatal-rat ventricular myocytes, while randomly oriented CNTs remained external to the cells. These results demonstrated that CNT electrodes can be leveraged to reduce impedance and enhance biological interfaces for microelectrodes of subcellular size.
Collapse
Affiliation(s)
- Andrew O Fung
- Biomedical Engineering Interdepartmental Program, University of California, Los Angeles, Los Angeles, California 90095, USA.
| | | | | | | | | | | | | |
Collapse
|
7
|
Bhandari R, Negi S, Rieth L, Solzbacher F. A Wafer-Scale Etching Technique for High Aspect Ratio Implantable MEMS Structures. SENSORS AND ACTUATORS. A, PHYSICAL 2010; 162:130-136. [PMID: 20706618 PMCID: PMC2917827 DOI: 10.1016/j.sna.2010.06.011] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Microsystem technology is well suited to batch fabricate microelectrode arrays, such as the Utah electrode array (UEA), intended for recording and stimulating neural tissue. Fabrication of the UEA is primarily based on the use of dicing and wet etching to achieve high aspect ratio (15:1) penetrating electrodes. An important step in the array fabrication is the etching of electrodes to produce needle-shape electrodes with sharp tips. Traditional etching processes are performed on a single array, and the etching conditions are not optimized. As a result, the process leads to variable geometries of electrodes within an array. Furthermore, the process is not only time consuming but also labor-intensive. This report presents a wafer-scale etching method for the UEA. The method offers several advantages, such as substantial reduction in the processing time, higher throughput and lower cost. More importantly, the method increases the geometrical uniformity from electrode to electrode within an array (1.5 ± 0.5 % non-uniformity), and from array to array within a wafer (2 ± 0.3 % non-uniformity). Also, the etching rate of silicon columns, produced by dicing, are studied as a function of temperature, etching time and stirring rate in a nitric acid rich HF-HNO(3) solution. These parameters were found to be related to the etching rates over the ranges studied and more-importantly affect the uniformity of the etched silicon columns. An optimum etching condition was established to achieve uniform shape electrode arrays on wafer-scale.
Collapse
Affiliation(s)
- R Bhandari
- Corresponding author: Rajmohan Bhandari,
| | | | | | | |
Collapse
|
8
|
Moxon K, Morizio J, Chapin J, Nicolelis M, Wolf P. Designing a Brain-Machine Interface for Neuroprosthetic Control. ACTA ACUST UNITED AC 2009. [DOI: 10.1201/9781420039054.pt2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
|
9
|
Gunalan K, Warren DJ, Perry JD, Normann RA, Clark GA. An automated system for measuring tip impedance and among-electrode shunting in high-electrode count microelectrode arrays. J Neurosci Methods 2009; 178:263-9. [DOI: 10.1016/j.jneumeth.2008.12.020] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2008] [Revised: 11/26/2008] [Accepted: 12/08/2008] [Indexed: 11/25/2022]
|
10
|
HajjHassan M, Chodavarapu V, Musallam S. NeuroMEMS: Neural Probe Microtechnologies. SENSORS 2008; 8:6704-6726. [PMID: 27873894 PMCID: PMC3707475 DOI: 10.3390/s8106704] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2008] [Revised: 09/27/2008] [Accepted: 10/21/2008] [Indexed: 11/25/2022]
Abstract
Neural probe technologies have already had a significant positive effect on our understanding of the brain by revealing the functioning of networks of biological neurons. Probes are implanted in different areas of the brain to record and/or stimulate specific sites in the brain. Neural probes are currently used in many clinical settings for diagnosis of brain diseases such as seizers, epilepsy, migraine, Alzheimer's, and dementia. We find these devices assisting paralyzed patients by allowing them to operate computers or robots using their neural activity. In recent years, probe technologies were assisted by rapid advancements in microfabrication and microelectronic technologies and thus are enabling highly functional and robust neural probes which are opening new and exciting avenues in neural sciences and brain machine interfaces. With a wide variety of probes that have been designed, fabricated, and tested to date, this review aims to provide an overview of the advances and recent progress in the microfabrication techniques of neural probes. In addition, we aim to highlight the challenges faced in developing and implementing ultra-long multi-site recording probes that are needed to monitor neural activity from deeper regions in the brain. Finally, we review techniques that can improve the biocompatibility of the neural probes to minimize the immune response and encourage neural growth around the electrodes for long term implantation studies.
Collapse
Affiliation(s)
- Mohamad HajjHassan
- Department of Electrical and Computer Engineering, McGill University, 3480 University Street, Montreal, Canada H3A 2A7.
| | - Vamsy Chodavarapu
- Department of Electrical and Computer Engineering, McGill University, 3480 University Street, Montreal, Canada H3A 2A7.
| | - Sam Musallam
- Department of Electrical and Computer Engineering, McGill University, 3480 University Street, Montreal, Canada H3A 2A7.
- Department of Physiology, McGill University, 3655 Promenade Osler, Montreal, Canada H3G 1Y6.
| |
Collapse
|
11
|
Selvakumaran J, Keddie JL, Ewins DJ, Hughes MP. Protein adsorption on materials for recording sites on implantable microelectrodes. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2008; 19:143-51. [PMID: 17587151 DOI: 10.1007/s10856-007-3110-x] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2005] [Accepted: 07/13/2006] [Indexed: 05/15/2023]
Abstract
Implantable microelectrodes have the potential to become part of neural prostheses to restore lost nerve function after nerve damage. The initial adsorption of proteins to materials for implantable microelectrodes is an important factor in determining the longevity and stability of the implant. Once an implant is in the body, protein adsorption takes place almost instantly before the cells reach the surface of an implant. The aim of this study was to identify an optimum material for electrode recording sites on implantable microelectrodes. Common materials for electrode sites are gold, platinum, iridium, and indium tin oxide. These, along with a reference material (titanium), were investigated. The thickness and the structure of adsorbed proteins on these materials were measured using a combination of atomic force microscopy and ellipsometry. The adsorbed protein layers on gold (after 7 and 28 days of exposure to serum) were the smoothest and the thinnest compared to all the other substrate materials, indicating that gold is the material of choice for electrode recording sites on implantable microelectrodes. However, the results also show that indium tin oxide might also be a good choice for these applications.
Collapse
Affiliation(s)
- Jamunanithy Selvakumaran
- Centre for Biomedical Engineering, School of Engineering, University of Surrey, Guildford, Surrey GU2 7XH, UK
| | | | | | | |
Collapse
|
12
|
Cieslewski G, Cheney D, Gugel K, Sanchez JC, Principe JC. Neural signal sampling via the low power wireless pico system. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2006:5904-7. [PMID: 17946727 DOI: 10.1109/iembs.2006.260506] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This paper presents a powerful new low power wireless system for sampling multiple channels of neural activity based on Texas Instruments MSP430 microprocessors and Nordic Semiconductor's ultra low power high bandwidth RF transmitters and receivers. The system's development process, component selection, features and test methodology are presented.
Collapse
|
13
|
Lee K, He J, Wang L. Benzocyclobutene (BCB) based neural implants with microfluidic channel. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2004:4326-9. [PMID: 17271262 DOI: 10.1109/iembs.2004.1404204] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Benzocyclobutene (BCB) based intracortical neural implants for basic neuroscience research in animal models was fabricated, in which microfluidic channel was embedded to deliver chemical reagents. BCB presents several attractive features for chronic applications: flexibility, biocompatibility, desirable chemical and electrical properties, and can be easily manufactured using existing batch microfabrication technology; The fabricated implants have single shank with three recording sites (20 x 20 microm) and two reservoirs (inlet and outlet). The channel had large volume (40 microm width and 10 microm height), and hydrophobic surface to provide a high degree of chemical inertness. All the recording sites were positioned near the end of the shank in order to increase the probability of recording neural signals from a target volume of tissue. In vitro biocompatibility tests of fabricated implants revealed no adverse toxic effects on cultured cells. The implant with a 5 microm silicon backbone layer penetrated rat's pia without buckling, a major drawback of polymer alone. The averaged impedance value at 1 kHz was approximately 1.2 MOmega. Water flowing through the channel was observed. Depending on the amount of the driving pressure from the syringes, the delivery speed of the water was totally controlled.
Collapse
Affiliation(s)
- K Lee
- Arizona Biodesign Institute, Arizona State University, Tempe, AZ, USA
| | | | | |
Collapse
|
14
|
Rowe L, Almasri M, Lee K, Fogleman N, Brewer GJ, Nam Y, Wheeler BC, Vukasinovic J, Glezer A, Frazier AB. Active 3-D microscaffold system with fluid perfusion for culturing in vitro neuronal networks. LAB ON A CHIP 2007; 7:475-82. [PMID: 17389964 DOI: 10.1039/b700795g] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
This work demonstrated the design, fabrication, packaging, and characterization of an active microscaffold system with fluid perfusion/nutrient delivery functionalities for culturing in vitro neuronal networks from dissociated hippocampal rat pup neurons. The active microscaffold consisted of an 8 x 8 array of hollow, microfabricated, SU-8 towers (1.0 mm or 1.5 mm in height), with integrated, horizontal, SU-8 cross-members that connect adjacent towers, thus forming a 3-D grid that is conducive to branching, growth, and increased network formation of dissociated hippocampal neurons. Each microtower in the microscaffold system contained a hollow channel and multiple fluid ports for media delivery and perfusion of nutrients to the in vitro neuronal network growing within the microscaffold system. Additionally, there were two exposed Au electrodes on the outer wall of each microtower at varying heights (with insulated leads running within the microtower walls), which will later allow for integration of electrical stimulation/recording functionalities into the active microscaffold system. However, characterization of the stimulation/recording electrodes was not included in the scope of this paper. Design, fabrication, fluid packaging, and characterization of the active microscaffold system were performed. Furthermore, use of the active microscaffold system was demonstrated by culturing primary hippocampal embryonic rat pup neurons, and characterizing cell viability within the microscaffold system.
Collapse
Affiliation(s)
- Laura Rowe
- School of Electrical and Computer Engineering, Georgia Institute of Technology, 791 Atlantic Drive, Atlanta, GA 30332, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Affiliation(s)
- Kensall D Wise
- Department of Electrical Engineering and Computer Science, The University of Michigan, Ann Arbor, MI 48109-2122, USA.
| |
Collapse
|
16
|
Muthuswamy J, Okandan M, Gilletti A, Baker MS, Jain T. An array of microactuated microelectrodes for monitoring single-neuronal activity in rodents. IEEE Trans Biomed Eng 2005; 52:1470-7. [PMID: 16119243 PMCID: PMC1635790 DOI: 10.1109/tbme.2005.851478] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Arrays of microelectrodes used for monitoring single- and multi-neuronal action potentials often fail to record from the same population of neurons over a period of time for several technical and biological reasons. We report here a novel Neural Probe chip with a 3-channel microactuated microelectrode array that will enable precise repositioning of the individual microelectrodes within the brain tissue after implantation. Thermal microactuators and associated microelectrodes in the Neural Probe chip are microfabricated using the Sandia's Ultraplanar Multi-level MEMS Technology (SUMMiTV) process, a 5-layer polysilicon micromachining technology of the Sandia National labs, Albuquerque, NM. The Neural Probe chip enables precise bi-directional positioning of the microelectrodes in the brain with a step resolution in the order of 8.8 microm. The thermal microactuators allow for a linear translation of the microelectrodes of up to 5 mm in either direction making it suitable for positioning microelectrodes in deep structures of a rodent brain. The overall translation in either direction was reduced to approximately 2 mm after insulation of the microelectrodes with epoxy for monitoring multi-unit activity. Single unit recordings were obtained from the somatosensory cortex of adult rats over a period of three days demonstrating the feasibility of this technology. Further optimization of the microelectrode insulation and chip packaging will be necessary before this technology can be validated in chronic experiments.
Collapse
Affiliation(s)
- Jit Muthuswamy
- Harrington Department of Bioengineering, ECG 334, P.O. Box 879709, Arizona State University, Tempe, AZ 85287-9709, USA.
| | | | | | | | | |
Collapse
|
17
|
Muthuswamy J, Okandan M, Jackson N. Single neuronal recordings using surface micromachined polysilicon microelectrodes. J Neurosci Methods 2005; 142:45-54. [PMID: 15652616 DOI: 10.1016/j.jneumeth.2004.07.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2003] [Revised: 04/23/2004] [Accepted: 07/22/2004] [Indexed: 10/26/2022]
Abstract
Bulk micromachining techniques of silicon have been used successfully in the past several years to microfabricate microelectrodes for monitoring single neurons in acute and chronic experiments. In this study we report for the first time a novel surface micromachining technique to microfabricate a very thin polysilicon microelectrode that can be used for monitoring single-unit activity in the central nervous system. The microelectrodes are 3 mm long and 50 microm x 3.75 microm in cross-section. Excellent signal to noise ratios in the order of 25-35 dB were obtained while recording neuronal action potentials. The microelectrodes successfully penetrated the brains after a microincision of the dura mater. Chronic implantation of the microprobe for up to 33 days produced only minor gliosis. Since the polysilicon shank acts as a conductor, additional processing steps involved in laying conductor lines on silicon substrates are avoided. Further, surface micromachining allows for fabricating extremely thin microelectrodes which could result in decreased inflammatory responses. We conclude that the polysilicon microelectrode reported here could be a complementary approach to bulk-micromachined silicon microelectrodes for chronic monitoring of single neurons in the central nervous system.
Collapse
Affiliation(s)
- Jit Muthuswamy
- Harrington Department of Bioengineering, ECG 334, College of Engineering and Applied Science, P.O. Box 879709, Arizona State University, Tempe, AZ 85287-9709, USA.
| | | | | |
Collapse
|
18
|
Moxon KA, Kalkhoran NM, Markert M, Sambito MA, McKenzie JL, Webster JT. Nanostructured Surface Modification of Ceramic-Based Microelectrodes to Enhance Biocompatibility for a Direct Brain-Machine Interface. IEEE Trans Biomed Eng 2004; 51:881-9. [PMID: 15188854 DOI: 10.1109/tbme.2004.827465] [Citation(s) in RCA: 104] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Many different types of microelectrodes have been developed for use as a direct Brain-Machine Interface (BMI) to chronically recording single neuron action potentials from ensembles of neurons. Unfortunately, the recordings from these microelectrode devices are not consistent and often last for only a few weeks. For most microelectrode types, the loss of these recordings is not due to failure of the electrodes but most likely due to damage to surrounding tissue that results in the formation of nonconductive glial-scar. Since the extracellular matrix consists of nanostructured microtubules, we have postulated that neurons may prefer a more complex surface structure than the smooth surface typical of thin-film microelectrodes. We, therefore, investigated the suitability of a nano-porous silicon surface layer to increase the biocompatibility of our thin film ceramic-insulated multisite electrodes. In-vitro testing demonstrated, for the first time, decreased adhesion of astrocytes and increased extension of neurites from pheochromocytoma cells on porous silicon surfaces compared to smooth silicon sufaces. Moreover, nano-porous surfaces were more biocompatible than macroporous surfaces. Collectively, these results support our hypothesis that nano-porous silicon may be an ideal material to improve biocompatibility of chronically implanted microelectrodes. We next developed a method to apply nano-porous surfaces to ceramic insulated, thin-film, microelectrodes and tested them in vivo. Chronic testing demonstrated that the nano-porous surface modification did not alter the electrical properties of the recording sites and did not interfere with proper functioning of the microelectrodes in vivo.
Collapse
Affiliation(s)
- Karen A Moxon
- School of Biomedical Engineering, Drexel University, 3141 Chestnut St, Philadelphia, PA 19104, USA.
| | | | | | | | | | | |
Collapse
|
19
|
Moxon KA, Leiser SC, Gerhardt GA, Barbee KA, Chapin JK. Ceramic-based multisite electrode arrays for chronic single-neuron recording. IEEE Trans Biomed Eng 2004; 51:647-56. [PMID: 15072219 DOI: 10.1109/tbme.2003.821037] [Citation(s) in RCA: 105] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A method is described for the manufacture of a microelectrode array for chronic, multichannel, single neuron recording. The ceramic-based, multisite electrode array has four recording sites patterned onto a ceramic shaft the size of a single typical microwire electrode. The sites and connecting wires are applied to the ceramic substrate using a reverse photolithographic procedure. Recording sites (22 x 80 microm) are separated by 200 microm along the shaft. A layer of alumina insulation is applied over the whole array (exclusive of recording sites) by ion-beam assisted deposition. These arrays were capable of recording single neuron activity from each of their recording sites for at least three weeks during chronic implantation in the somatosensory cortex of rats, and several sites had recordings that lasted for more than 8 weeks. The vertical arrangement of the recording sites on these electrodes is ideal for simultaneously recording across the different layers of brain areas such as the cerebral cortex and hippocampus in chronic preparations.
Collapse
Affiliation(s)
- Karen A Moxon
- School of Biomedical Engineering Science and Health System, Drexel University, Philadelphia, PA 19104, USA
| | | | | | | | | |
Collapse
|
20
|
Tyler DJ, Durand DM. Functionally selective peripheral nerve stimulation with a flat interface nerve electrode. IEEE Trans Neural Syst Rehabil Eng 2002; 10:294-303. [PMID: 12611367 DOI: 10.1109/tnsre.2002.806840] [Citation(s) in RCA: 227] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
One of the important goals of peripheral nerve electrode development is to design an electrode for selective recruitment of the different functions of a common nerve trunk. A challenging task is gaining selective access to central axon populations. In this paper, a simple electrode that takes advantage of the neural plasticity to reshape the nerve is presented. The flat interface nerve electrode (FINE) reshapes the nerve into a flat geometry to increase the surface area and move central axon populations close to the surface. The electrode was implanted acutely on the sciatic nerve of eight cats. The FINE can significantly reshape the nerve and fascicles (p < 0.0001) while maintaining the same total nerve cross-sectional area. The stimulation thresholds were 2.89 nC for pulse amplitude modulation and 10.2 nC for pulse-width modulation. Monopolar, square-pulse stimulation with single contacts on the FINE selectively recruited each of the four main branches of the sciatic nerve. Simultaneous stimulation with two contacts produced moments about the ankle joint that were a combination of the moments produced by the individual contacts when stimulated separately.
Collapse
Affiliation(s)
- Dustin J Tyler
- Neural Engineering Center, Applied Neural Control Lab, Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA
| | | |
Collapse
|
21
|
Ufheil J, Borgwarth K, Heinze J. Introduction to the principles of ultramicroheptodes in ring-disk interactions. Anal Chem 2002; 74:1316-21. [PMID: 11922299 DOI: 10.1021/ac010912z] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The use of ring-disk ultramicroelectrodes as tips as a means of extending the methodology of the scanning electrochemical microscope is described. Electrodes consisting of one centered disk with six interconnected disks surrounding it served as the ring-disk electrodes. Basic experiments illustrate the behavior in the feedback mode and the generation collection mode. The dependence on the electrodes' size, both potentials, the tip-sample distance, and the local properties of the underying sample were studied. When approaching an electrode to the surface of a sample, steady-state collection efficiencies between zero and unity were elegantly altered by adjusting the distance between tip and sample. The shielding factor could be varied between 0.25 and 0.82 the same way. Concerning feedback methods, the results presented illustrate the new principle of applying a precisely located external stimulus as a separate electrochemical means of analyzing the sample's response. Obviously, this technique can be extended to irreversible redox mediators, which are not treated here explicitly, but give this concept even greater flexibility. The interpretation of such data can be deduced directly from this contribution.
Collapse
Affiliation(s)
- Joachim Ufheil
- Institut für Physikalische Chemie, Albert-Ludwigs-Universität Freiburg, Germany
| | | | | |
Collapse
|
22
|
|
23
|
Rousche PJ, Pellinen DS, Pivin DP, Williams JC, Vetter RJ, Kipke DR. Flexible polyimide-based intracortical electrode arrays with bioactive capability. IEEE Trans Biomed Eng 2001; 48:361-71. [PMID: 11327505 DOI: 10.1109/10.914800] [Citation(s) in RCA: 335] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The promise of advanced neuroprosthetic systems to significantly improve the quality of life for a segment of the deaf, blind, or paralyzed population hinges on the development of an efficacious, and safe, multichannel neural interface for the central nervous system. The candidate implantable device that is to provide such an interface must exceed a host of exacting design parameters. We present a thin-film, polyimide-based, multichannel intracortical Bio-MEMS interface manufactured with standard planar photo-lithographic CMOS-compatible techniques on 4-in silicon wafers. The use of polyimide provides a mechanically flexible substrate which can be manipulated into unique three-dimensional designs. Polyimide also provides an ideal surface for the selective attachment of various important bioactive species onto the device in order to encourage favorable long-term reactions at the tissue-electrode interface. Structures have an integrated polyimide cable providing efficient contact points for a high-density connector. This report details in vivo and in vitro device characterization of the biological, electrical and mechanical properties of these arrays. Results suggest that these arrays could be a candidate device for long-term neural implants.
Collapse
Affiliation(s)
- P J Rousche
- Bioengineering Department, Arizona State University, Tempe 85287-6006, USA
| | | | | | | | | | | |
Collapse
|
24
|
Abstract
Cellular activation mapping (specifying in time and space the electrical activation sequence of cells) is a well-established basic research tool in cardiac, neural, and gastric physiology. Much recent research in cardiac mapping has focused on large arrays (>200 electrodes) with small electrodes (<500 microm). Construction of such arrays using standard techniques is tedious and yields irregular electrode spacing. We present a novel construction technique that rapidly produces large arrays with regularly spaced small electrodes. For methods, fine-pitch copper ribbon cables, insulated with either polyvinylchloride (PVC) or polyimide (flexible printed circuit; FPC), were assembled together such that the active surface was the cut end of the cable. The cut end was sanded and polished, then coated with silver and sometimes silver chloride. Once completed, the alternating current (AC) root-mean-square (rms) potential was measured between two adjacent, individual electrodes. Polarization testing was conducted according to a previously reported protocol (Witkowski FX and Penkoske PA. J Electrocardiol 21: 273-282, 1988). Activation mapping was conducted in the open-chest guinea pig with both pacing- and defibrillation- strength stimuli. In terms of results, four PVC and three FPC arrays were constructed, ranging from 4 to 400 electrodes. Two hours of labor were needed to create a complete electrode array, independent of the number of electrodes, including connectors and silver/silver chloride coating. As expected, the addition of a silver/silver chloride coating significantly reduced (0.76-0.42 mV, P < 0.001) the AC rms potential difference between two electrodes. A nearly immediate recovery of the potential difference between adjacent pairs of silver/silver chloride electrodes was observed after defibrillation stimuli.
Collapse
Affiliation(s)
- R A Malkin
- The Joint Department of Biomedical Engineering, The University of Tennessee-Memphis and The University of Memphis, Memphis 38152, Tennessee, USA.
| | | |
Collapse
|
25
|
Kam L, Shain W, Turner JN, Bizios R. Correlation of astroglial cell function on micro-patterned surfaces with specific geometric parameters. Biomaterials 1999; 20:2343-50. [PMID: 10614940 DOI: 10.1016/s0142-9612(99)00163-5] [Citation(s) in RCA: 56] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Microcontact printing techniques were used to modify silicon substrates with arrays of hexagonal features of N1[3-(trimethoxysilyl) propyl]diethylenetriamine (DETA) surrounded by octadecyltrichlorosilane (OTS), which are hydrophilic, cell-adhesive and hydrophobic, non-adhesive organosilanes, respectively. In the presence of serum proteins, LRM55 cell adhesion and morphology on these modified surfaces were best correlated to the width of the cell-adhesive features. On surfaces modified with small (5 microm in width) cell-adhesive features, LRM55 cells elaborated only thin processes. As feature width was increased, cells on these surfaces exhibited increased cell spreading and elaborated wide processes. On surfaces modified with large (>35 microm in width) features, single cells adhered to and spread upon individual DETA features. In a similar fashion, LRM55 cell adhesion density increased with increasing feature width; this correlation could be represented by a simple, second-order relation, and was independent of all other measures of pattern geometry. The results of this study provide evidence that micro-patterning may be effective in controlling astrocyte interaction with implant materials.
Collapse
Affiliation(s)
- L Kam
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180-3590, USA
| | | | | | | |
Collapse
|
26
|
Akin T, Ziaie B, Nikles SA, Najafi K. A modular micromachined high-density connector system for biomedical applications. IEEE Trans Biomed Eng 1999; 46:471-80. [PMID: 10217885 DOI: 10.1109/10.752944] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This paper presents a high-density, modular, low-profile, small, and removable connector system developed using micromachining technologies for biomedical applications. This system consists of a silicon or polyimide electrode with one end in contact with the biological tissue and its back-end supported in a titanium base (12.5 mm in diameter and 2.5 mm in height) that is fixed on the test subject. An external glass substrate (6 x 6 x 0.75 mm3), which supports a flexible polyimide diaphragm and CMOS buffers, is attached to the titanium base whenever electrical contact is required. The polyimide flexible diaphragm contains high-density gold electroplated pads (32 pads, each having an area of 100 x 100 micron 2 and separated by 150 microns) which match similar pads on the electrode back-end. When vacuum is applied between the two, the polyimide diaphragm deflects and the corresponding gold pads touch, therefore, establishing electrical connection. In vitro electrical tests in saline solution have been performed on a 32-site connector system demonstrating < 5 omega contact resistance, which remained stable after 70 connections, and -55 dB crosstalk at 1 kHz between adjacent channels. In vivo experiments have also confirmed the establishment of multiple contacts and have produced simultaneous biopotential recordings from the guinea pig occipital cortex.
Collapse
Affiliation(s)
- T Akin
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara, Turkey
| | | | | | | |
Collapse
|
27
|
Turner JN, Shain W, Szarowski DH, Andersen M, Martins S, Isaacson M, Craighead H. Cerebral astrocyte response to micromachined silicon implants. Exp Neurol 1999; 156:33-49. [PMID: 10192775 DOI: 10.1006/exnr.1998.6983] [Citation(s) in RCA: 391] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The treatment of neurologic disorders and the restoration of lost function due to trauma by neuroprosthetic devices has been pursued for over 20 years. The methodology for fabricating miniature devices with sophisticated electronic functions to interface with nervous system tissue is available, having been well established by the integrated circuit industry. Unfortunately, the effectiveness of these devices is severely limited by the tissue reaction to the insertion and continuous presence of the implant, a foreign object. This study was designed to document the response of reactive astrocytes in the hope that this information will be useful in specifying new fabrication technologies and devices capable of prolonged functioning in the brain. Model probes fabricated from single crystal silicon wafers were implanted into the cerebral cortices of rats. The probes had a 1 x 1-mm tab, for handling, and a 2-mm-long shaft with a trapezoidal cross-section (200-microm base, 60microm width at the top, and 130 microm height). The tissue response was studied by light and scanning electron microscopy at postinsertion times ranging from 2 to 12 weeks. A continuous sheath of cells was found to surround the insertion site in all tissue studied and was well developed but loosely organized at 2 weeks. By 6 and 12 weeks, the sheath was highly compacted and continuous, isolating the probe from the brain. At 2 and 4 weeks, the sheath was disrupted when the probe was removed from the fixed tissue, indicating that cells attached more strongly to the surface of the probe than to the nearby tissue. The later times showed much less disruption. Scanning electron microscopy of the probes showed adherent cells or cell fragments at all time points. Thus, as the sheath became compact, the cells on the probe and the cells in the sheath had decreased adhesion to each other. Immunocytochemistry demonstrated that the sheath was labeled with antibodies to glial fibrillary acidic protein (GFAP), an indicator for reactive gliosis. The tissue surrounding the insertion site showed an increased number of GFAP-positive cells which tended to return to control levels as a function of time after probe insertion. It was concluded that reactive gliosis is an important part of the process forming the cellular sheath. Further, the continuous presence of the probe appears to result in a sustained response that produces and maintains a compact sheath, at least partially composed of reactive glia, which isolates the probe from the brain.
Collapse
Affiliation(s)
- J N Turner
- Wadsworth Center, New York State Department of Health, Albany, New York 12201-0509, USA
| | | | | | | | | | | | | |
Collapse
|
28
|
|
29
|
Rousche PJ, Normann RA. Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex. J Neurosci Methods 1998; 82:1-15. [PMID: 10223510 DOI: 10.1016/s0165-0270(98)00031-4] [Citation(s) in RCA: 493] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The Utah Intracortical Electrode Array (UIEA) is an array of 100 penetrating silicon microelectrodes designed to focally electrically stimulate or record neurons residing in a single layer up to 1.5 mm beneath the surface of the cerebral cortex. Apart from its use as a unique tool to study parallel processing in the central nervous system, this array could form the platform for a cortical neuroprosthetic system. Although the UIEA has been used extensively in acute neural recording and stimulation experiments, its long-term performance in a chronic application has yet to be demonstrated. As an initial investigation into the feasibility of long-term cortical recording with an array of microelectrodes, we have hard-wired a subset of 11 electrodes of the UIEA to a percutaneous connector. This chronic UIEA assembly was then implanted into the cerebral cortices of ten cats for durations ranging from 2 to 13 months; over which time, both random and stimulus-evoked single and multiple unit action potentials were periodically recorded. On average, after a 6-month implant period, 60% of implanted arrays could still record some type of activity. Post-sacrifice dissections revealed a fibrous encapsulation of the UIEA. Although most implanted cortex was histologically normal, evidence of a chronic astroglial response was seen in a few cases. The results of the reported experiments indicate that the UIEA can be successfully used for limited times in a chronic recording application.
Collapse
Affiliation(s)
- P J Rousche
- Department of Optometry and Visual Sciences, University of Manchester Institute of Science and Technology, UK
| | | |
Collapse
|
30
|
Jones KE, Normann RA. An advanced demultiplexing system for physiological stimulation. IEEE Trans Biomed Eng 1997; 44:1210-20. [PMID: 9401220 DOI: 10.1109/10.649992] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
A CMOS very large scale integration (VLSI) chip has been designed and built to implement a scheme developed for multiplexing/demultiplexing the signals required to operate an intracortical stimulating electrode array. Because the use of radio telemetry in a proposed system utilizing this chip may impose limits upon the rate of data transmission to the chip, the scheme described herein was used to reduce the amount of digital information which must be sent to control a large quantity (up to several hundred) of stimulating electrodes. By incorporating multiple current sources on chip, many channels may be stimulated simultaneously. By incorporating on-chip timers, control over pulse timing is assigned to the chip, reducing by up to fourfold the amount of control data which must be sent. By incorporating on-chip RAM, information associated with the desired stimulus amplitude and pulse timing can be stored on chip. In this manner, it is necessary to send control information to the chip only when the information changes, rather than at the stimulus repeat rate for each channel. This further reduces the data rate by a factor of five to ten times or more. The architecture described here, implemented as an eight-channel stimulator, is scalable to a 625-channel stimulator while keeping data transmission rates under 2 Mbps.
Collapse
Affiliation(s)
- K E Jones
- Department of Bioengineering, University of Utah, Salt Lake City 84112, USA
| | | |
Collapse
|
31
|
|
32
|
Hoogerwerf AC, Wise KD. A three-dimensional microelectrode array for chronic neural recording. IEEE Trans Biomed Eng 1994; 41:1136-46. [PMID: 7851915 DOI: 10.1109/10.335862] [Citation(s) in RCA: 282] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
This paper describes a 3-D microelectrode array for the chronic recording of single-unit activity in the central nervous system. The array is formed by a microassembly of planar silicon multishank microprobes, which are precisely positioned in a micromachined platform that resides on the surface of the cortex. Interconnects between the probes and the platform are formed using electroplated nickel lead transfers, implemented using automated computer control. All dimensions are controlled to +/- 1 micron and sank/probe separations as small as 100 microns are possible. Four-probe 16-shank prototype arrays have been tested chronically in guinea pig cortex. After three months in vivo, no significant tissue reaction has been observed surrounding these structures when they remain free to move with the brain, with normal appearing tissue between shanks spaced at 150 microns to 200 microns intervals. The array structure is compatible with the use of signal processing circuitry both on the probes and on the platform. A platform-based signal processing system has been designed to interface with several active probes, providing direct analog access to the recording sites, performing on-chip analog-to-digital conversion of neural activity, and providing simple binary-output recognition of single-unit spike events using a user-input threshold voltage.
Collapse
Affiliation(s)
- A C Hoogerwerf
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor 48109-2122
| | | |
Collapse
|
33
|
Djupsjöbacka M, Johansson H, Bergenheim M, Sandström U. A multichannel hook electrode for simultaneous recording of up to 12 nerve filaments. J Neurosci Methods 1994; 52:69-72. [PMID: 8090020 DOI: 10.1016/0165-0270(94)90058-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
This paper describes a simple multichannel hook electrode specially adapted for simultaneous recording from several dorsal root filaments in the cat. The electrode consists of a 3-mm-thick PVC plate and accommodates 12 silver wire hooks placed in notches in the plate. It has a semicircular shape, and the notches are milled radially in the plate. With this electrode we have made successful recordings of single-unit activity from 12 muscle afferents for periods of up to 8 h. In contrast to more rigid and complicated devices, e.g., developed to assess activity of populations of individual neurones from single-channel recordings of multi-unit activity, it also permits selection of the types of afferents to be recorded. The use of this simple device and an appropriate number of amplifiers and window discriminators can greatly enhance the quality of studies on populations of afferents in animals and may also decrease the number of laboratory animals needed.
Collapse
Affiliation(s)
- M Djupsjöbacka
- Division of Work Physiology, National Institute of Occupational Health, Umeå, Sweden
| | | | | | | |
Collapse
|
34
|
Nordhausen CT, Rousche PJ, Normann RA. Optimizing recording capabilities of the Utah Intracortical Electrode Array. Brain Res 1994; 637:27-36. [PMID: 8180807 DOI: 10.1016/0006-8993(94)91213-0] [Citation(s) in RCA: 82] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
The Utah Intracortical Electrode Array is a unique silicon-based monolithic structure designed for use as a multichannel interface to the central nervous system. In this paper, we describe a series of acute experiments designed to determine the neural recording capabilities of this electrode array and the dependence of the signal-to-noise ratio (SNR) of the recordings on the electrode surface area (length of metallized tip). We found that both separable unit and multiunit cluster responses could be recorded. Additionally, high SNR recordings could be achieved for some electrodes (with electrode tip lengths of 30-220 microns), while recordings with signals substantially greater than the noise could be made from most of the electrodes provided that the proper electrode surface area was used. The demonstrated recording capabilities of the Utah Intracortical Electrode Array and its unique three-dimensional structure should form the basis for innovative physiological investigations into the functional organization of the cortex as well as for long term neuroprosthesis development.
Collapse
Affiliation(s)
- C T Nordhausen
- Department of Bioengineering, University of Utah, Salt Lake City 84112
| | | | | |
Collapse
|
35
|
Abstract
Modern technology is allowing researchers to collect data from neural ensembles with a large number of units, and the analysis of interaction between these units can be very time consuming. Estimation of pairwise connectivity is the most common method of determining the neural 'network' but usually necessitates the production of numerous histograms for each pair considered. We present a method which will indicate which pairs in a network represent potential connections and thereby simplify the postexperimental analysis. The technique uses cross-interval information to create an n x n matrix which represents all possible connections in an n neuron ensemble and can be calculated recursively on-line. The performance of this technique is analyzed with respect to data size and strength of the connections. It is compared to 2 similar techniques that are also presented here, one in which perfect knowledge of the timing of the excitation is known, and one in which the timing can be bounded.
Collapse
Affiliation(s)
- B W Edwards
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor 48109-2122
| | | |
Collapse
|