1
|
Salahandish R, Haghayegh F, Ayala-Charca G, Hyun JE, Khalghollah M, Zare A, Far B, Berenger BM, Niu YD, Ghafar-Zadeh E, Sanati-Nezhad A. Bi-ECDAQ: An electrochemical dual-immuno-biosensor accompanied by a customized bi-potentiostat for clinical detection of SARS-CoV-2 Nucleocapsid proteins. Biosens Bioelectron 2022; 203:114018. [PMID: 35114466 PMCID: PMC8786409 DOI: 10.1016/j.bios.2022.114018] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 01/08/2022] [Accepted: 01/15/2022] [Indexed: 01/10/2023]
Abstract
Multiplex electrochemical biosensors have been used for eliminating the matrix effect in complex bodily fluids or enabling the detection of two or more bioanalytes, overall resulting in more sensitive assays and accurate diagnostics. Many electrochemical biosensors lack reliable and low-cost multiplexing to meet the requirements of point-of-care detection due to either limited functional biosensors for multi-electrode detection or incompatible readout systems. We developed a new dual electrochemical biosensing unit accompanied by a customized potentiostat to address the unmet need for point-of-care multi-electrode electrochemical biosensing. The two-working electrode system was developed using screen-printing of a carboxyl-rich nanomaterial containing ink, with both working electrodes offering active sites for recognition of bioanalytes. The low-cost bi-potentiostat system (∼$80) was developed and customized specifically to the bi-electrode design and used for rapid, repeatable, and accurate measurement of electrochemical impedance spectroscopy signals from the dual biosensor. This binary electrochemical data acquisition (Bi-ECDAQ) system accurately and selectively detected SARS-CoV-2 Nucleocapsid protein (N-protein) in both spiked samples and clinical nasopharyngeal swab samples of COVID-19 patients within 30 min. The two working electrodes offered the limit of detection of 116 fg/mL and 150 fg/mL, respectively, with the dynamic detection range of 1-10,000 pg/mL and the sensitivity range of 2744-2936 Ω mL/pg.mm2 for the detection of N-protein. The potentiostat performed comparable or better than commercial Autolab potentiostats while it is significantly lower cost. The open-source Bi-ECDAQ presents a customizable and flexible approach towards addressing the need for rapid and accurate point-of-care electrochemical biosensors for the rapid detection of various diseases.
Collapse
Affiliation(s)
- Razieh Salahandish
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada; Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada
| | - Fatemeh Haghayegh
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada; Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada
| | - Giancarlo Ayala-Charca
- Biologically Inspired Sensors and Actuators (BioSA), Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, M3J1P3, Canada
| | - Jae Eun Hyun
- Alberta Public Health Laboratory, Alberta Precision Laboratories, 3330 Hospital Drive, Calgary, Alberta, T2N 4W4, Canada
| | - Mahmood Khalghollah
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada; Department of Electrical and Software Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada
| | - Azam Zare
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada
| | - Behrouz Far
- Department of Electrical and Software Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada
| | - Byron M Berenger
- Alberta Public Health Laboratory, Alberta Precision Laboratories, 3330 Hospital Drive, Calgary, Alberta, T2N 4W4, Canada; Department of Pathology and Laboratory Medicine, University of Calgary, 3535 Research Rd, Calgary, Alberta, T2L 1Y1, Canada
| | - Yan Dong Niu
- Department of Pathology and Laboratory Medicine, University of Calgary, 3535 Research Rd, Calgary, Alberta, T2L 1Y1, Canada; Department of Ecosystem and Public Health, Faculty of Veterinary Medicine, University of Calgary, Calgary, Alberta, T2N 1N4, Canada.
| | - Ebrahim Ghafar-Zadeh
- Biologically Inspired Sensors and Actuators (BioSA), Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, M3J1P3, Canada.
| | - Amir Sanati-Nezhad
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada; Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada; Biomedical Engineering Graduate Program, University of Calgary, Calgary, Alberta, T2N 1N4, Canada.
| |
Collapse
|
2
|
Falk M, Psotta C, Cirovic S, Shleev S. Non-Invasive Electrochemical Biosensors Operating in Human Physiological Fluids. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6352. [PMID: 33171750 PMCID: PMC7664326 DOI: 10.3390/s20216352] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Revised: 11/03/2020] [Accepted: 11/04/2020] [Indexed: 12/14/2022]
Abstract
Non-invasive healthcare technologies are an important part of research and development nowadays due to the low cost and convenience offered to both healthcare receivers and providers. This work overviews the recent advances in the field of non-invasive electrochemical biosensors operating in secreted human physiological fluids, viz. tears, sweat, saliva, and urine. Described electrochemical devices are based on different electrochemical techniques, viz. amperometry, coulometry, cyclic voltammetry, and impedance spectroscopy. Challenges that confront researchers in this exciting area and key requirements for biodevices are discussed. It is concluded that the field of non-invasive sensing of biomarkers in bodily fluid is highly convoluted. Nonetheless, if the drawbacks are appropriately addressed, and the pitfalls are adroitly circumvented, the approach will most certainly disrupt current clinical and self-monitoring practices.
Collapse
Affiliation(s)
- Magnus Falk
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
| | - Carolin Psotta
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
- Aptusens AB, 293 94 Kyrkhult, Sweden
| | - Stefan Cirovic
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
| | - Sergey Shleev
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
- Aptusens AB, 293 94 Kyrkhult, Sweden
| |
Collapse
|
3
|
Sassa F, Biswas GC, Suzuki H. Microfabricated electrochemical sensing devices. LAB ON A CHIP 2020; 20:1358-1389. [PMID: 32129358 DOI: 10.1039/c9lc01112a] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Electrochemistry provides possibilities to realize smart microdevices of the next generation with high functionalities. Electrodes, which constitute major components of electrochemical devices, can be formed by various microfabrication techniques, and integration of the same (or different) components for that purpose is not difficult. Merging this technique with microfluidics can further expand the areas of application of the resultant devices. To augment the development of next generation devices, it will be beneficial to review recent technological trends in this field and clarify the directions required for moving forward. Even when limiting the discussion to electrochemical microdevices, a variety of useful techniques should be considered. Therefore, in this review, we attempted to provide an overview of all relevant techniques in this context in the hope that it can provide useful comprehensive information.
Collapse
Affiliation(s)
- Fumihiro Sassa
- Graduate School of Information Science and Electrical Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan
| | | | | |
Collapse
|
4
|
Trotter M, Borst N, Thewes R, von Stetten F. Review: Electrochemical DNA sensing – Principles, commercial systems, and applications. Biosens Bioelectron 2020; 154:112069. [DOI: 10.1016/j.bios.2020.112069] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 01/28/2020] [Accepted: 02/01/2020] [Indexed: 02/06/2023]
|
5
|
Li H, Lu Y, Wong PK. Diffusion-reaction kinetics of microfluidic amperometric biosensors. LAB ON A CHIP 2018; 18:3086-3089. [PMID: 30207365 DOI: 10.1039/c8lc00794b] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Amperometric biosensors are widely applied for rapid biomarker detection in physiological and environmental samples. The dynamics and linearity of the current signal, however, are only partially understood. This study investigates the diffusion-reaction kinetics of amperometric biosensing using a self-assembled monolayer (SAM) based biosensor for bacterial 16S rRNA. A numerical model is developed to optimize the chamber dimensions and elucidate the concentration dependences of the biosensor. The results revealed that depletion of substrates associated with the chamber dimension can limit the current signal in a target concentration dependent manner. This study provides practical guidelines in the design and interpretation of microfluidic amperometric biosensors for biochemical applications.
Collapse
Affiliation(s)
- Hui Li
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA, USA.
| | | | | |
Collapse
|
6
|
Davenport M, Mach KE, Shortliffe LMD, Banaei N, Wang TH, Liao JC. New and developing diagnostic technologies for urinary tract infections. Nat Rev Urol 2017; 14:296-310. [PMID: 28248946 PMCID: PMC5473291 DOI: 10.1038/nrurol.2017.20] [Citation(s) in RCA: 183] [Impact Index Per Article: 22.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Timely and accurate identification and determination of the antimicrobial susceptibility of uropathogens is central to the management of UTIs. Urine dipsticks are fast and amenable to point-of-care testing, but do not have adequate diagnostic accuracy or provide microbiological diagnosis. Urine culture with antimicrobial susceptibility testing takes 2-3 days and requires a clinical laboratory. The common use of empirical antibiotics has contributed to the rise of multidrug-resistant organisms, reducing treatment options and increasing costs. In addition to improved antimicrobial stewardship and the development of new antimicrobials, novel diagnostics are needed for timely microbial identification and determination of antimicrobial susceptibilities. New diagnostic platforms, including nucleic acid tests and mass spectrometry, have been approved for clinical use and have improved the speed and accuracy of pathogen identification from primary cultures. Optimization for direct urine testing would reduce the time to diagnosis, yet these technologies do not provide comprehensive information on antimicrobial susceptibility. Emerging technologies including biosensors, microfluidics, and other integrated platforms could improve UTI diagnosis via direct pathogen detection from urine samples, rapid antimicrobial susceptibility testing, and point-of-care testing. Successful development and implementation of these technologies has the potential to usher in an era of precision medicine to improve patient care and public health.
Collapse
Affiliation(s)
- Michael Davenport
- Department of Urology, Stanford University School of Medicine, 300 Pasteur Drive S-287, Stanford, California 94305 USA
| | - Kathleen E Mach
- Department of Urology, Stanford University School of Medicine, 300 Pasteur Drive S-287, Stanford, California 94305 USA
| | - Linda M Dairiki Shortliffe
- Department of Urology, Stanford University School of Medicine, 300 Pasteur Drive S-287, Stanford, California 94305 USA
| | - Niaz Banaei
- Department of Pathology, Stanford University School of Medicine, 3375 Hillview Avenue, Palo Alto, California 94304 USA
| | - Tza-Huei Wang
- Departments of Mechanical and Biomedical Engineering, Johns Hopkins University, 3400 N. Charles Street, Baltimore, Maryland 21218, USA
| | - Joseph C Liao
- Department of Urology, Stanford University School of Medicine, 300 Pasteur Drive S-287, Stanford, California 94305 USA
- Veterans Affairs Palo Alto Health Care System, 3801 Miranda Avenue, Palo Alto, California 94304 USA
| |
Collapse
|
7
|
Lu Y, Ren Q, Liu T, Leung SL, Gau V, Liao JC, Chan CL, Wong PK. Long-range electrothermal fluid motion in microfluidic systems. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER 2016; 98:341-349. [PMID: 27127306 PMCID: PMC4843167 DOI: 10.1016/j.ijheatmasstransfer.2016.03.034] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
AC electrothermal flow (ACEF) is the fluid motion created as a result of Joule heating induced temperature gradients. ACEF is capable of performing major microfluidic operations, such as pumping, mixing, concentration, separation and assay enhancement, and is effective in biological samples with a wide range of electrical conductivity. Here, we report long-range fluid motion induced by ACEF, which creates centimeter-scale vortices. The long-range fluid motion displays a strong voltage dependence and is suppressed in microchannels with a characteristic length below ~300 μm. An extended computational model of ACEF, which considers the effects of the density gradient and temperature-dependent parameters, is developed and compared experimentally by particle image velocimetry. The model captures the essence of ACEF in a wide range of channel dimensions and operating conditions. The combined experimental and computational study reveals the essential roles of buoyancy, temperature rise, and associated changes in material properties in the formation of the long-range fluid motion. Our results provide critical information for the design and modeling of ACEF based microfluidic systems toward various bioanalytical applications.
Collapse
Affiliation(s)
- Yi Lu
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, Arizona, 85721, USA
- Departments of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802 USA
| | - Qinlong Ren
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, Arizona, 85721, USA
| | - Tingting Liu
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, Arizona, 85721, USA
| | - Siu Ling Leung
- Departments of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802 USA
- College of Medicine, The University of Arizona, Tucson, 85724, USA
| | - Vincent Gau
- GeneFluidics Inc., Irwindale, California, 91010, USA
| | - Joseph C. Liao
- Department of Urology, Stanford University, Stanford, California, 94305, USA
| | - Cho Lik Chan
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, Arizona, 85721, USA
| | - Pak Kin Wong
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, Arizona, 85721, USA
- Departments of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802 USA
- Departments of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802 USA
- Department of Surgery, Milton S. Hershey Medical Center, The Pennsylvania State University, Hershey, PA 17033 USA
| |
Collapse
|
8
|
Gao J, Jeffries L, Mach KE, Craft DW, Thomas NJ, Gau V, Liao JC, Wong PK. A Multiplex Electrochemical Biosensor for Bloodstream Infection Diagnosis. SLAS Technol 2016; 22:466-474. [PMID: 27226118 DOI: 10.1177/2211068216651232] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Accurate and timely detection of bacterial pathogens will improve the clinical management of infections. Herein, we demonstrate an electrochemical biosensor that directly detects bacteria in human blood samples, resulting in the rapid diagnosis of a bloodstream infection. The multiplex biosensor detects the species-specific sequences of the 16S ribosomal RNA of bacteria for pathogen identification in physiological samples without preamplification. The analytical performance characteristics of the biosensor, including the limit of detection and probe cross-reactivity, are evaluated systematically. The feasibility of the biosensor for a diagnosis of a bloodstream infection is demonstrated by identifying bacterial clinical isolates spiked in whole blood and blood culture samples that were tested positive for bacteria. The electrochemical biosensor correctly identifies all the species in the samples with 100% concordance to microbiological analysis.
Collapse
Affiliation(s)
- Jian Gao
- 1 Department of Biomedical Engineering, Pennsylvania State University, University Park, PA, USA
| | - Lindsie Jeffries
- 2 Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, USA
| | - Kathleen E Mach
- 3 Department of Urology, Stanford University School of Medicine, Stanford, CA, USA
| | - David W Craft
- 4 Pathology and Laboratory Medicine, Penn State Milton S. Hershey Medical Center, Hershey, PA, USA
| | - Neal J Thomas
- 5 Departments of Pediatrics and Public Health Sciences, Penn State University College of Medicine, Hershey, PA, USA
| | | | - Joseph C Liao
- 3 Department of Urology, Stanford University School of Medicine, Stanford, CA, USA
| | - Pak Kin Wong
- 1 Department of Biomedical Engineering, Pennsylvania State University, University Park, PA, USA.,7 Department of Mechanical Engineering, Pennsylvania State University, University Park, PA, USA.,8 Department of Surgery, Penn State Milton S. Hershey Medical Center, Hershey, PA, USA
| |
Collapse
|
9
|
Henihan G, Schulze H, Corrigan DK, Giraud G, Terry JG, Hardie A, Campbell CJ, Walton AJ, Crain J, Pethig R, Templeton KE, Mount AR, Bachmann TT. Label- and amplification-free electrochemical detection of bacterial ribosomal RNA. Biosens Bioelectron 2016; 81:487-494. [PMID: 27016627 DOI: 10.1016/j.bios.2016.03.037] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Revised: 03/09/2016] [Accepted: 03/17/2016] [Indexed: 01/13/2023]
Abstract
Current approaches to molecular diagnostics rely heavily on PCR amplification and optical detection methods which have restrictions when applied to point of care (POC) applications. Herein we describe the development of a label-free and amplification-free method of pathogen detection applied to Escherichia coli which overcomes the bottleneck of complex sample preparation and has the potential to be implemented as a rapid, cost effective test suitable for point of care use. Ribosomal RNA is naturally amplified in bacterial cells, which makes it a promising target for sensitive detection without the necessity for prior in vitro amplification. Using fluorescent microarray methods with rRNA targets from a range of pathogens, an optimal probe was selected from a pool of probe candidates identified in silico. The specificity of probes was investigated on DNA microarray using fluorescently labeled 16S rRNA target. The probe yielding highest specificity performance was evaluated in terms of sensitivity and a LOD of 20 pM was achieved on fluorescent glass microarray. This probe was transferred to an EIS end point format and specificity which correlated to microarray data was demonstrated. Excellent sensitivity was facilitated by the use of uncharged PNA probes and large 16S rRNA target and investigations resulted in an LOD of 50 pM. An alternative kinetic EIS assay format was demonstrated with which rRNA could be detected in a species specific manner within 10-40min at room temperature without wash steps.
Collapse
Affiliation(s)
- Grace Henihan
- Division of Infection and Pathway Medicine, College of Medicine and Veterinary Medicine, The University of Edinburgh, Chancellor's Building, 49 Little France Crescent, Edinburgh EH16 4SB, Scotland, UK
| | - Holger Schulze
- Division of Infection and Pathway Medicine, College of Medicine and Veterinary Medicine, The University of Edinburgh, Chancellor's Building, 49 Little France Crescent, Edinburgh EH16 4SB, Scotland, UK
| | - Damion K Corrigan
- Division of Infection and Pathway Medicine, College of Medicine and Veterinary Medicine, The University of Edinburgh, Chancellor's Building, 49 Little France Crescent, Edinburgh EH16 4SB, Scotland, UK; School of Chemistry, The University of Edinburgh, Joseph Black Building, The King's Buildings, West Mains Road, Edinburgh EH9 3JJ, Scotland, UK
| | - Gerard Giraud
- School of Physics and Astronomy, The University of Edinburgh, The King's Buildings, West Mains Road, Edinburgh EH9 3JZ, Scotland, UK
| | - Jonathan G Terry
- Institute for Integrated Micro and Nano Systems, School of Engineering, The University of Edinburgh, Alexander Crum Brown Road, Edinburgh EH9 3FF, Scotland, UK
| | - Alison Hardie
- Department of Laboratory Medicine, Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, Scotland, UK
| | - Colin J Campbell
- School of Chemistry, The University of Edinburgh, Joseph Black Building, The King's Buildings, West Mains Road, Edinburgh EH9 3JJ, Scotland, UK
| | - Anthony J Walton
- Institute for Integrated Micro and Nano Systems, School of Engineering, The University of Edinburgh, Alexander Crum Brown Road, Edinburgh EH9 3FF, Scotland, UK
| | - Jason Crain
- School of Physics and Astronomy, The University of Edinburgh, The King's Buildings, West Mains Road, Edinburgh EH9 3JZ, Scotland, UK; National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, UK
| | - Ronald Pethig
- Institute for Integrated Micro and Nano Systems, School of Engineering, The University of Edinburgh, Alexander Crum Brown Road, Edinburgh EH9 3FF, Scotland, UK
| | - Kate E Templeton
- Division of Infection and Pathway Medicine, College of Medicine and Veterinary Medicine, The University of Edinburgh, Chancellor's Building, 49 Little France Crescent, Edinburgh EH16 4SB, Scotland, UK; Department of Laboratory Medicine, Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, Scotland, UK
| | - Andrew R Mount
- School of Chemistry, The University of Edinburgh, Joseph Black Building, The King's Buildings, West Mains Road, Edinburgh EH9 3JJ, Scotland, UK
| | - Till T Bachmann
- Division of Infection and Pathway Medicine, College of Medicine and Veterinary Medicine, The University of Edinburgh, Chancellor's Building, 49 Little France Crescent, Edinburgh EH16 4SB, Scotland, UK.
| |
Collapse
|
10
|
Lu Y, Liu T, Lamanda AC, Sin MLY, Gau V, Liao JC, Wong PK. AC Electrokinetics of Physiological Fluids for Biomedical Applications. ACTA ACUST UNITED AC 2014; 20:611-20. [PMID: 25487557 DOI: 10.1177/2211068214560904] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2014] [Indexed: 12/13/2022]
Abstract
Alternating current (AC) electrokinetics is a collection of processes for manipulating bulk fluid mass and embedded objects with AC electric fields. The ability of AC electrokinetics to implement the major microfluidic operations, such as pumping, mixing, concentration, and separation, makes it possible to develop integrated systems for clinical diagnostics in nontraditional health care settings. The high conductivity of physiological fluids presents new challenges and opportunities for AC electrokinetics-based diagnostic systems. In this review, AC electrokinetic phenomena in conductive physiological fluids are described followed by a review of the basic microfluidic operations and the recent biomedical applications of AC electrokinetics. The future prospects of AC electrokinetics for clinical diagnostics are presented.
Collapse
Affiliation(s)
- Yi Lu
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ, USA
| | - Tingting Liu
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ, USA
| | - Ariana C Lamanda
- Biomedical Engineering, The University of Arizona, Tucson, AZ, USA
| | - Mandy L Y Sin
- Department of Urology, Stanford University, Stanford, CA, USA Veterans Affairs Palo Alto Health Care System, Palo Alto, CA, USA
| | | | - Joseph C Liao
- Department of Urology, Stanford University, Stanford, CA, USA Veterans Affairs Palo Alto Health Care System, Palo Alto, CA, USA
| | - Pak Kin Wong
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ, USA Biomedical Engineering, The University of Arizona, Tucson, AZ, USA
| |
Collapse
|
11
|
Protein Microarrays with Novel Microfluidic Methods: Current Advances. MICROARRAYS 2014; 3:180-202. [PMID: 27600343 PMCID: PMC4996363 DOI: 10.3390/microarrays3030180] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Revised: 06/10/2014] [Accepted: 06/16/2014] [Indexed: 01/08/2023]
Abstract
Microfluidic-based micromosaic technology has allowed the pattering of recognition elements in restricted micrometer scale areas with high precision. This controlled patterning enabled the development of highly multiplexed arrays multiple analyte detection. This arraying technology was first introduced in the beginning of 2001 and holds tremendous potential to revolutionize microarray development and analyte detection. Later, several microfluidic methods were developed for microarray application. In this review we discuss these novel methods and approaches which leverage the property of microfluidic technologies to significantly improve various physical aspects of microarray technology, such as enhanced imprinting homogeneity, stability of the immobilized biomolecules, decreasing assay times, and reduction of the costs and of the bulky instrumentation.
Collapse
|
12
|
Sin MLY, Mach KE, Wong PK, Liao JC. Advances and challenges in biosensor-based diagnosis of infectious diseases. Expert Rev Mol Diagn 2014; 14:225-44. [PMID: 24524681 DOI: 10.1586/14737159.2014.888313] [Citation(s) in RCA: 199] [Impact Index Per Article: 18.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Rapid diagnosis of infectious diseases and timely initiation of appropriate treatment are critical determinants that promote optimal clinical outcomes and general public health. Conventional in vitro diagnostics for infectious diseases are time-consuming and require centralized laboratories, experienced personnel and bulky equipment. Recent advances in biosensor technologies have potential to deliver point-of-care diagnostics that match or surpass conventional standards in regards to time, accuracy and cost. Broadly classified as either label-free or labeled, modern biosensors exploit micro- and nanofabrication technologies and diverse sensing strategies including optical, electrical and mechanical transducers. Despite clinical need, translation of biosensors from research laboratories to clinical applications has remained limited to a few notable examples, such as the glucose sensor. Challenges to be overcome include sample preparation, matrix effects and system integration. We review the advances of biosensors for infectious disease diagnostics and discuss the critical challenges that need to be overcome in order to implement integrated diagnostic biosensors in real world settings.
Collapse
Affiliation(s)
- Mandy L Y Sin
- Department of Urology, Stanford University School of Medicine , Stanford, CA 94305-5118 , USA
| | | | | | | |
Collapse
|