1
|
Barbruni GL, Rodino F, Ros PM, Demarchi D, Ghezzi D, Carrara S. A Wearable Real-Time System for Simultaneous Wireless Power and Data Transmission to Cortical Visual Prosthesis. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:580-591. [PMID: 38261488 DOI: 10.1109/tbcas.2024.3357626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2024]
Abstract
Wireless, miniaturised and distributed neural interfaces are emerging neurotechnologies. Although extensive research efforts contribute to their technological advancement, the need for real-time systems enabling simultaneous wireless information and power transfer toward distributed neural implants remains crucial. Here we present a complete wearable system including a software for real-time image capturing, processing and digital data transfer; an hardware for high radiofrequency generation and modulation via amplitude shift keying; and a 3-coil inductive link adapt to operate with multiple miniaturised receivers. The system operates in real-time with a maximum frame rate of 20 Hz, reconstructing each frame with a matrix of 32 × 32 pixels. The device generates a carrier frequency of 433.92 MHz. It transmits the highest power of 32 dBm with a data rate of 6 Mbps and a variable modulation index as low as 8 %, thus potentially enabling wireless communication with 1024 miniaturised and distributed intracortical microstimulators. The system is primarily conceived as an external wearable device for distributed cortical visual prosthesis covering a visual field of 20 °. At the same time, it is modular and versatile, being suitable for multiple applications requiring simultaneous wireless information and power transfer to large-scale neural interfaces.
Collapse
|
2
|
Eskandari R, Sawan M. Challenges and Perspectives on Impulse Radio-Ultra-Wideband Transceivers for Neural Recording Applications. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:369-382. [PMID: 37938944 DOI: 10.1109/tbcas.2023.3331049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
Brain-machine interfaces (BMI) are widely adopted in neuroscience investigations and neural prosthetics, with sensing channel counts constantly increasing. These Investigations place increasing demands for high data rates and low-power implantable devices despite high tissue losses. The Impulse radio ultra-wideband (IR-UWB), a revived wireless technology for short-range radios, has been widely used in various applications. Since the requirements and solutions are application-oriented, in this review paper we focus on neural recording implants with high-data rates and ultra-low power requirements. We examine in detail the working principle, design methodology, performance, and implementations of different architectures of IR-UWB transceivers in a quantitative manner to draw a deep comparison and extract the bottlenecks and possible solutions concerning the dedicated application. Our analysis shows that current solutions rely on enhanced or combined modulation techniques to improve link margin. An in-depth study of prior-art publications that achieved Gbps data rates concludes that edge-combination architecture and non-coherent detectors are remarkable for transmitter and receiver, respectively. Although the aim to minimize power and improve data rate - defined as energy efficiency (pJ/b) - extending communication distance despite high tissue losses and limited power budget, good narrow-band interference (NBI) tolerance coexisted in the same frequency band of UWB systems, and compatibility with energy harvesting designs are among the critical challenges remained unsolved. Furthermore, we expect that the combination of artificial intelligence (AI) and the inherent advantages of UWB radios will pave the way for future improvements in BMIs.
Collapse
|
3
|
Kouhalvandi L, Matekovits L, Peter I. Amplifiers in Biomedical Engineering: A Review from Application Perspectives. SENSORS (BASEL, SWITZERLAND) 2023; 23:2277. [PMID: 36850873 PMCID: PMC9961860 DOI: 10.3390/s23042277] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 01/22/2023] [Accepted: 02/15/2023] [Indexed: 05/31/2023]
Abstract
Continuous monitoring and treatment of various diseases with biomedical technologies and wearable electronics has become significantly important. The healthcare area is an important, evolving field that, among other things, requires electronic and micro-electromechanical technologies. Designed circuits and smart devices can lead to reduced hospitalization time and hospitals equipped with high-quality equipment. Some of these devices can also be implanted inside the body. Recently, various implanted electronic devices for monitoring and diagnosing diseases have been presented. These instruments require communication links through wireless technologies. In the transmitters of these devices, power amplifiers are the most important components and their performance plays important roles. This paper is devoted to collecting and providing a comprehensive review on the various designed implanted amplifiers for advanced biomedical applications. The reported amplifiers vary with respect to the class/type of amplifier, implemented CMOS technology, frequency band, output power, and the overall efficiency of the designs. The purpose of the authors is to provide a general view of the available solutions, and any researcher can obtain suitable circuit designs that can be selected for their problem by reading this survey.
Collapse
Affiliation(s)
- Lida Kouhalvandi
- Department of Electrical and Electronics Engineering, Dogus University, Istanbul 34775, Turkey
| | - Ladislau Matekovits
- Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Turin, Italy
- Department of Measurements and Optical Electronics, Politehnica University Timisoara, 300006 Timisoara, Romania
- Istituto di Elettronica e di Ingegneria dell’Informazione e delle Telecomunicazioni, National Research Council, 10129 Turin, Italy
| | - Ildiko Peter
- Department of Industrial Engineering and Management, University of Medicine, Pharmacy, Science and Technology “George Emil Palade”, 540139 Targu Mures, Romania
| |
Collapse
|
4
|
Song M, Huang Y, Visser HJ, Romme J, Liu YH. An Energy-Efficient and High-Data-Rate IR-UWB Transmitter for Intracortical Neural Sensing Interfaces. IEEE JOURNAL OF SOLID-STATE CIRCUITS 2022; 57:3656-3668. [PMID: 36743394 PMCID: PMC7614137 DOI: 10.1109/jssc.2022.3212672] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
This paper presents an implantable impulse-radio ultra-wideband (IR-UWB) wireless telemetry system for intracortical neural sensing interfaces. A 3-dimensional (3-D) hybrid impulse modulation that comprises phase shift keying (PSK), pulse position modulation (PPM) and pulse amplitude modulation (PAM) is proposed to increase modulation order without significantly increasing the demodulation requirement, thus leading to a high data rate of 1.66 Gbps and an increased air-transmission range. Operating in 6 - 9 GHz UWB band, the presented transmitter (TX) supports the proposed hybrid modulation with a high energy efficiency of 5.8 pJ/bit and modulation quality (EVM< -21 dB). A low-noise injection-locked ring oscillator supports 8-PSK with a phase error of 2.6°. A calibration free delay generator realizes a 4-PPM with only 115 μW and avoids potential cross-modulation between PPM and PSK. A switch-cap power amplifier with an asynchronous pulse-shaping performs 4-PAM with high energy efficiency and linearity. The TX is implemented in 28 nm CMOS technology, occupying 0.155mm2 core area. The wireless module including a printed monopole antenna has a module area of only 1.05 cm2. The transmitter consumes in total 9.7 mW when transmitting -41.3 dBm/MHz output power. The wireless telemetry module has been validated ex-vivo with a 15-mm multi-layer porcine tissue, and achieves a communication (air) distance up to 15 cm, leading to at least 16× improvement in distance-moralized energy efficiency of 45 pJ/bit/meter compared to state-of-the-art.
Collapse
|
5
|
Soltani N, Jafari HM, Abdelhalim K, Kassiri H, Liu X, Genov R. A 21.3%-Efficiency Clipped-Sinusoid UWB Impulse Radio Transmitter With Simultaneous Inductive Powering and Data Receiving. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:1228-1238. [PMID: 36445989 DOI: 10.1109/tbcas.2022.3225304] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
An ultra-wide-band impulse-radio (UWB-IR) transmitter (TX) for low-energy biomedical microsystems is presented. High power efficiency is achieved by modulating an LC tank that always resonates in the steady state during transmission. A new clipped-sinusoid scheme is proposed for on-off keying (OOK)-modulation, which is implemented by a voltage clipper circuit with on-chip biasing generation. The TX is designed to provide a high data-rate wireless link within the 3-5 GHz band. The chip was fabricated in 130 nm CMOS technology and fully characterized. State-of-the-art power efficiency of 21.3% was achieved at a data-rate of 230 Mbps and energy consumption of 21pJ/b. A bit-error-rate (BER) of less than 10 -6 was measured at a distance of 1 m without pulse averaging. In addition, simultaneous wireless powering and VCO-based data transmission are supported. A potential extension to a VCO-free all-wireless mode to further reduce the power consumption is also discussed.
Collapse
|
6
|
Shi C, Song M, Gao Z, Bevilacqua A, Dolmans G, Liu YH. Galvanic-coupled Trans-dural Data Transfer for High-bandwidth Intra-cortical Neural Sensing. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES 2022; 70:4579-4589. [PMID: 36846311 PMCID: PMC7614244 DOI: 10.1109/tmtt.2022.3198100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
A digital-impulse galvanic coupling as a new high-speed trans-dural (from cortex to the skull) data transmission method has been presented in this paper. The proposed wireless telemetry replaces the tethered wires connected in between implants on the cortex and above the skull, allowing the brain implant to be "free-floating" for minimizing brain tissue damage. Such trans-dural wireless telemetry must have a wide channel bandwidth for high-speed data transfer and a small form factor for minimum invasiveness. To investigate the propagation property of the channel, a finite element model is developed and a channel characterization based on a liquid phantom and porcine tissue is performed. The results show that the trans-dural channel has a wide frequency response of up to 250 MHz. Propagation loss due to micro-motion and misalignments is also investigated in this work. The result indicates that the proposed transmission method is relatively insensitive to misalignment. It has approximately 1 dB extra loss when there is a horizontal misalignment of 1mm. A pulse-based transmitter ASIC and a miniature PCB module are designed and validated ex-vivo with a 10-mm thick porcine tissue. This work demonstrates a high-speed and miniature in-body galvanic-coupled pulse-based communication with a data rate up to 250 Mbps with an energy efficiency of 2 pJ/bit, and has a small module area of only 26 mm2.
Collapse
|
7
|
Valente V. Evolution of Biotelemetry in Medical Devices: From Radio Pills to mm-Scale Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:580-599. [PMID: 35834463 DOI: 10.1109/tbcas.2022.3190767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The advent of semiconductor technology in the mid-20th century created unprecedented opportunities to develop a new generation of small-scale wireless medical sensing devices that can support remote monitoring of patients' vital signs. The first radio pills were developed as early as the 1950's using only a few transistors. These swallowable capsules could sense and wirelessly transmit vital parameters from inside the human body. Since then we have witnessed the rapid progress of medical devices driven by the evolution of semiconductor technology, from single-transistor oscillators to complex mixed-signal multi-channel and multi-modal systems. This paper retraces the evolution of biotelemetry devices from their very early inception to the smart miniaturized systems of modern days, focusing on semiconductor-enabled sensing methods and circuits developed over the last six decades. The paper also includes the author's perspective on current and future trends in the development of CMOS-based biotelemeters, focusing on concepts of implant modularity, miniaturization and hybrid energy harvesting solutions.
Collapse
|
8
|
Kim HJ, Ho JS. Wireless interfaces for brain neurotechnologies. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2022; 380:20210020. [PMID: 35658679 DOI: 10.1098/rsta.2021.0020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 12/13/2021] [Indexed: 06/15/2023]
Abstract
Wireless interfaces enable brain-implanted devices to remotely interact with the external world. They are critical components in modern research and clinical neurotechnologies and play a central role in determining their overall size, lifetime and functionality. Wireless interfaces use a wide range of modalities-including radio-frequency fields, acoustic waves and light-to transfer energy and data to and from an implanted device. These forms of energy interact with living tissue through distinct mechanisms and therefore lead to systems with vastly different form factors, operating characteristics, and safety considerations. This paper reviews recent advances in the development of wireless interfaces for brain neurotechnologies. We summarize the requirements that state-of-the-art brain-implanted devices impose on the wireless interface, and discuss the working principles and applications of wireless interfaces based on each modality. We also investigate challenges associated with wireless brain neurotechnologies and discuss emerging solutions permitted by recent developments in electrical engineering and materials science. This article is part of the theme issue 'Advanced neurotechnologies: translating innovation for health and well-being'.
Collapse
Affiliation(s)
- Han-Joon Kim
- Department of Electrical and Computer Engineering National University of Singapore, Queenstown, Singapore
| | - John S Ho
- Department of Electrical and Computer Engineering National University of Singapore, Queenstown, Singapore
- The N.1 Institute for Health National University of Singapore, Queenstown, Singapore
- Institute for Health Innovation and Technology, National University of Singapore, Queenstown, Singapore
| |
Collapse
|
9
|
Song M, Huang Y, Shen Y, Shi C, Breeschoten A, Konijnenburg M, Visser H, Romme J, Dutta B, Alavi MS, Bachmann C, Liu YH. A 1.66Gb/s and 5.8pJ/b Transcutaneous IR-UWB Telemetry System with Hybrid Impulse Modulation for Intracortical Brain-Computer Interfaces. DIGEST OF TECHNICAL PAPERS. IEEE INTERNATIONAL SOLID-STATE CIRCUITS CONFERENCE 2022; 2022:394-396. [PMID: 36844419 PMCID: PMC7614245 DOI: 10.1109/isscc42614.2022.9731608] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
| | - Yu Huang
- imec-Netherlands, Eindhoven, The Netherlands,Delft University of Technology, Delft, The Netherlands
| | - Yiyu Shen
- imec-Netherlands, Eindhoven, The Netherlands
| | - Chengyao Shi
- imec-Netherlands, Eindhoven, The Netherlands,Eindhoven University of Technology, Eindhoven, The Netherlands
| | | | | | - Huib Visser
- imec-Netherlands, Eindhoven, The Netherlands
| | - Jac Romme
- imec-Netherlands, Eindhoven, The Netherlands
| | | | | | | | | |
Collapse
|
10
|
Lin YJ, Song H, Oh S, Voroslakos M, Kim K, Chen X, Wentzloff DD, Buzsaki G, Park SY, Yoon E. A 3.1-5.2GHz, Energy-Efficient Single Antenna, Cancellation-Free, Bitwise Time-Division Duplex Transceiver for High Channel Count Optogenetic Neural Interface. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:52-63. [PMID: 34982690 DOI: 10.1109/tbcas.2021.3139891] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
We report an energy-efficient, cancellation-free, bit-wise time-division duplex (B-TDD) transceiver (TRX) for real-time closed-loop control of high channel count neural interfaces. The proposed B-TDD architecture consists of a duty-cycled ultra-wide band (UWB) transmitter (3.1-5 GHz) and a switching U-NII band (5.2 GHz) receiver. An energy-efficient duplex is realized in a single antenna without power-hungry self-interference cancellation circuits which are prevalently used in the conventional full-duplex, single antenna transceivers. To suppress the interference between up- and down-links and enhance the isolation between the two, we devised a fast-switching scheme in a low noise amplifier and used 5× oversampling with a built-in winner-take-all voting in the receiver. The B-TDD transceiver was fabricated in 65 nm CMOS RF process, achieving low energy consumption of 0.32 nJ/b at 10 Mbps in the receiver and 9.7 pJ/b at 200 Mbps in the transmitter, respectively. For validation, the B-TDD TRX has been integrated with a μLED optoelectrode and a custom analog frontend integrated circuit in a prototype wireless bidirectional neural interface system. Successful in-vivo operation for simultaneously recording broadband neural signals and optical stimulation was demonstrated in a transgenic rodent.
Collapse
|
11
|
Shupe LE, Miles FP, Jones G, Yun R, Mishler J, Rembado I, Murphy RL, Perlmutter SI, Fetz EE. Neurochip3: An Autonomous Multichannel Bidirectional Brain-Computer Interface for Closed-Loop Activity-Dependent Stimulation. Front Neurosci 2021; 15:718465. [PMID: 34489634 PMCID: PMC8417105 DOI: 10.3389/fnins.2021.718465] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Accepted: 07/22/2021] [Indexed: 11/13/2022] Open
Abstract
Toward addressing many neuroprosthetic applications, the Neurochip3 (NC3) is a multichannel bidirectional brain-computer interface that operates autonomously and can support closed-loop activity-dependent stimulation. It consists of four circuit boards populated with off-the-shelf components and is sufficiently compact to be carried on the head of a non-human primate (NHP). NC3 has six main components: (1) an analog front-end with an Intan biophysical signal amplifier (16 differential or 32 single-ended channels) and a 3-axis accelerometer, (2) a digital control system comprised of a Cyclone V FPGA and Atmel SAM4 MCU, (3) a micro SD Card for 128 GB or more storage, (4) a 6-channel differential stimulator with ±60 V compliance, (5) a rechargeable battery pack supporting autonomous operation for up to 24 h and, (6) infrared transceiver and serial ports for communication. The NC3 and earlier versions have been successfully deployed in many closed-loop operations to induce synaptic plasticity and bridge lost biological connections, as well as deliver activity-dependent intracranial reinforcement. These paradigms to strengthen or replace impaired connections have many applications in neuroprosthetics and neurorehabilitation.
Collapse
Affiliation(s)
- Larry E Shupe
- Department of Physiology & Biophysics, University of Washington, Seattle, WA, United States.,Washington National Primate Research Center, University of Washington, Seattle, WA, United States
| | - Frank P Miles
- Washington National Primate Research Center, University of Washington, Seattle, WA, United States
| | - Geoff Jones
- Independent Researcher, Seattle, CA, United States
| | - Richy Yun
- Department of Bioengineering, University of Washington, Seattle, WA, United States
| | - Jonathan Mishler
- Department of Bioengineering, University of Washington, Seattle, WA, United States
| | - Irene Rembado
- Department of Physiology & Biophysics, University of Washington, Seattle, WA, United States
| | - R Logan Murphy
- Department of Physiology & Biophysics, University of Washington, Seattle, WA, United States
| | - Steve I Perlmutter
- Department of Physiology & Biophysics, University of Washington, Seattle, WA, United States.,Washington National Primate Research Center, University of Washington, Seattle, WA, United States
| | - Eberhard E Fetz
- Department of Physiology & Biophysics, University of Washington, Seattle, WA, United States.,Washington National Primate Research Center, University of Washington, Seattle, WA, United States.,Department of Bioengineering, University of Washington, Seattle, WA, United States
| |
Collapse
|
12
|
Lyu H, Babakhani A. A 13.56-MHz -25-dBm-Sensitivity Inductive Power Receiver System-on-a-Chip With a Self-Adaptive Successive Approximation Resonance Compensation Front-End for Ultra-Low-Power Medical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:80-90. [PMID: 33373302 PMCID: PMC9215201 DOI: 10.1109/tbcas.2020.3047827] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Battery-less and ultra-low-power implantable medical devices (IMDs) with minimal invasiveness are the latest therapeutic paradigm. This work presents a 13.56-MHz inductive power receiver system-on-a-chip with an input sensitivity of -25.4 dBm (2.88 μW) and an efficiency of 46.4% while driving a light load of 30 μW. In particular, a real-time resonance compensation scheme is proposed to mitigate resonance variations commonly seen in IMDs due to different dielectric environments, loading conditions, and fabrication mismatches, etc. The power-receiving front-end incorporates a 6-bit capacitor bank that is periodically adjusted according to a successive-approximation-resonance-tuning (SART) algorithm. The compensation range is as much as 24 pF and it converges within 12 clock cycles and causes negligible power consumption overhead. The harvested voltage from 1.7 V to 3.3 V is digitized on-chip and transmitted via an ultra-wideband impulse radio (IR-UWB) back-telemetry for closed-loop regulation. The IC is fabricated in 180-nm CMOS process with an overall current dissipation of 750 nA. At a separation distance of 2 cm, the end-to-end power transfer efficiency reaches 16.1% while driving the 30-μW load, which is immune to artificially induced resonance capacitor offsets. The proposed system can be applied to various battery-less IMDs with the potential improvement of the power transfer efficiency on orders of magnitude.
Collapse
|
13
|
Chong H, Majerus SJ, Bogie KM, Zorman CA. Non‐hermetic packaging of biomedical microsystems from a materials perspective: A review. ACTA ACUST UNITED AC 2020. [DOI: 10.1002/mds3.10082] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Hao Chong
- Department of Electrical, Computer, and Systems Engineering Case Western Reserve University Cleveland OH USA
| | | | - Kath M. Bogie
- APT Center Louis Stokes VA Medical Center Cleveland OH USA
- Department of Orthopaedics Case Western Reserve University School of Medicine Cleveland OH USA
| | - Christian A. Zorman
- Department of Electrical, Computer, and Systems Engineering Case Western Reserve University Cleveland OH USA
- APT Center Louis Stokes VA Medical Center Cleveland OH USA
| |
Collapse
|
14
|
Liu Y, Urso A, Martins da Ponte R, Costa T, Valente V, Giagka V, Serdijn WA, Constandinou TG, Denison T. Bidirectional Bioelectronic Interfaces: System Design and Circuit Implications. ACTA ACUST UNITED AC 2020. [DOI: 10.1109/mssc.2020.2987506] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
15
|
Abstract
The technological ability to capture electrophysiological activity of populations of cortical neurons through chronic implantable devices has led to significant advancements in the field of brain-computer interfaces. Recent progress in the field has been driven by developments in integrated microelectronics, wireless communications, materials science, and computational neuroscience. Here, we review major device development landmarks in the arena of neural interfaces from FDA-approved clinical systems to prototype head-mounted and fully implantable wireless systems for multi-channel neural recording. Additionally, we provide an outlook toward next-generation, highly miniaturized technologies for minimally invasive, vastly parallel neural interfaces for naturalistic, closed-loop neuroprostheses.
Collapse
|
16
|
Matic T, Sneler L, Herceg M. An Energy Efficient Multi-User Asynchronous Wireless Transmitter for Biomedical Signal Acquisition. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:619-630. [PMID: 31107660 DOI: 10.1109/tbcas.2019.2917690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The paper presents a novel transmitter architecture for short-range asynchronous wireless communication, applicable to simultaneous multi-user wireless acquisition of biological signals. The analog signal, provided from an analog biosensor, is transformed to time information using an Integral Pulse Frequency Modulator (IPFM) as a Time-Encoding Machine. The IPFM generates a time-encoded unipolar pulse train, maintaining the linear dependence of the output pulse distance on analog input voltage. The system enables continuous acquisition of the signals from multiple sensors in which each transmitter has unique feedback loop delay used for multi-user coding. IPFM pulses trigger the Impulse Radio Ultra-Wideband pulse generator directly, providing two ultra-wideband (UWB) pulses per each IPFM pulse. Due to the lack of internal clock signal and microprocessor-free multi-user coding, the circuitry satisfies the requirements of multi-user coding energy efficiency and size reduction, which are crucial demands in biomedical applications. The proposed Time-Encoded UWB (TE-UWB) transmitter is implemented in 0.18 [Formula: see text] CMOS technology. Measurement results of the IPFM transfer function for input voltage ranging from 0.15 to 1.5 V are presented, providing the dependence of the IPFM pulse time distance on analog input voltage and power consumption dependence on the input voltage level. For continuous monitoring operation, total power consumption of the transmitter circuitry for the maximum input voltage is 10.8 [Formula: see text], while for the lowest input voltage it increases to 40.48 [Formula: see text]. The circuit occupies 0.14 [Formula: see text].
Collapse
|
17
|
Trigui A, Hached S, Ammari AC, Savaria Y, Sawan M. Maximizing Data Transmission Rate for Implantable Devices Over a Single Inductive Link: Methodological Review. IEEE Rev Biomed Eng 2018; 12:72-87. [PMID: 30295628 DOI: 10.1109/rbme.2018.2873817] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Due to the constantly growing geriatric population and the projected increase of the prevalence of chronic diseases that are refractory to drugs, implantable medical devices (IMDs) such as neurostimulators, endoscopic capsules, artificial retinal prostheses, and brain-machine interfaces are being developed. According to many business forecast firms, the IMD market is expected to grow and they are subject to much research aiming to overcome the numerous challenges of their development. One of these challenges consists of designing a wireless power and data transmission system that has high power efficiency, high data rates, low power consumption, and high robustness against noise. This is in addition to minimal design and implementation complexity. This manuscript concerns a comprehensive survey of the latest techniques used to power up and communicate between an external base station and an IMD. Patient safety considerations related to biological, physical, electromagnetic, and electromagnetic interference concerns for wireless IMDs are also explored. The simultaneous powering and data communication techniques using a single inductive link for both power transfer and bidirectional data communication, including the various data modulation/demodulation techniques, are also reviewed. This review will hopefully contribute to the persistent efforts to implement compact reliable IMDs while lowering their cost and upsurging their benefits.
Collapse
|
18
|
Rezaei M, Maghsoudloo E, Bories C, De Koninck Y, Gosselin B. A Low-Power Current-Reuse Analog Front-End for High-Density Neural Recording Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2018; 12:271-280. [PMID: 29570055 DOI: 10.1109/tbcas.2018.2805278] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Studying brain activity in vivo requires collecting bioelectrical signals from several microelectrodes simultaneously in order to capture neuron interactions. In this work, we present a new current-reuse analog front-end (AFE), which is scalable to very large numbers of recording channels, thanks to its small implementation silicon area and its low-power consumption. This current-reuse AFE, which is including a low-noise amplifier (LNA) and a programmable gain amplifier (PGA), employs a new fully differential current-mirror topology using fewer transistors, and improving several design parameters, such as power consumption and noise, over previous current-reuse amplifier circuit implementations. We show that the proposed current-reuse amplifier can provide a theoretical noise efficiency factor (NEF) as low as 1.01, which is the lowest reported theoretical NEF provided by an LNA topology. A foue-channel current-reuse AFE implemented in a CMOS 0.18-μm technology is presented as a proof-of-concept. T-network capacitive circuits are used to decrease the size of input capacitors and to increase the gain accuracy in the AFE. The measured performance of the whole AFE is presented. The total power consumption per channel, including the LNA and the PGA stage, is 9 μW (4.5 μW for LNA and 4.5 μW for PGA), for an input referred noise of 3.2 μVrms, achieving a measured NEF of 1.94. The entire AFE presents three selectable gains of 35.04, 43.1, and 49.5 dB, and occupies a die area of 0.072 mm2 per channel. The implemented circuit has a measured inter-channel rejection ratio of 54 dB. In vivo recording results obtained with the proposed AFE are reported. It successfully allows collecting low-amplitude extracellular action potential signals from a tungsten wire microelectrode implanted in the hippocampus of a laboratory mouse.
Collapse
|
19
|
Yeon P, Mirbozorgi SA, Lim J, Ghovanloo M. Feasibility Study on Active Back Telemetry and Power Transmission Through an Inductive Link for Millimeter-Sized Biomedical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2017; 11:1366-1376. [PMID: 29293426 DOI: 10.1109/tbcas.2017.2775638] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This paper presents a feasibility study of wireless power and data transmission through an inductive link to a 1-mm 2 implant, to be used as a free-floating neural probe, distributed across a brain area of interest. The proposed structure utilizes a four-coil inductive link for back telemetry, shared with a three-coil link for wireless power transmission. We propose a design procedure for geometrical optimization of the inductive link in terms of power transmission efficiency (PTE) considering specific absorption rate and data rate. We have designed a low-power pulse-based active data transmission circuit and characterized performance of the proposed inductive link in terms of its data rate and bit error rate (BER). The 1-mm2 data-Tx/power-Rx coil is implemented using insulated bonding wire with diameter, resulting in measured PTE in tissue media of 2.01% at 131 MHz and 1.8-cm coil separation distance when the resonator coil inner radius is 1 cm. The measured BER at 1-Mbps data rate was and in the air and tissue environments, respectively.
Collapse
|
20
|
Lo YK, Kuan YC, Culaclii S, Kim B, Wang PM, Chang CW, Massachi JA, Zhu M, Chen K, Gad P, Edgerton VR, Liu W. A Fully Integrated Wireless SoC for Motor Function Recovery After Spinal Cord Injury. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2017; 11:497-509. [PMID: 28489550 PMCID: PMC5562024 DOI: 10.1109/tbcas.2017.2679441] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
This paper presents a wirelessly powered, fully integrated system-on-a-chip (SoC) supporting 160-channel stimulation, 16-channel recording, and 48-channel bio-impedance characterization to enable partial motor function recovery through epidural spinal cord electrical stimulation. A wireless transceiver is designed to support quasi full-duplex data telemetry at a data rate of 2 Mb/s. Furthermore, a unique in situ bio-impedance characterization scheme based on time-domain analysis is implemented to derive the Randles cell electrode model of the electrode-electrolyte interface. The SoC supports concurrent stimulation and recording while the high-density stimulator array meets an output compliance voltage of up to ±10 V with versatile stimulus programmability. The SoC consumes 18 mW and occupies a chip area of 5.7 mm × 4.4 mm using 0.18 μm high-voltage CMOS process. In our in vivo rodent experiment, the SoC is used to perform wireless recording of EMG responses while stimulation is applied to enable the standing and stepping of a paralyzed rat. To facilitate the system integration, a novel thin film polymer packaging technique is developed to provide a heterogeneous integration of the SoC, coils, discrete components, and high-density flexible electrode array, resulting in a miniaturized prototype implant with a weight and form factor of 0.7 g and 0.5 cm3, respectively.
Collapse
|
21
|
Lee J, Jang J, Song YK. A review on wireless powering schemes for implantable microsystems in neural engineering applications. Biomed Eng Lett 2016. [DOI: 10.1007/s13534-016-0242-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
22
|
Rezaei M, Bahrami H, Mirbozorgi A, Rusch LA, Gosselin B. A short-impulse UWB BPSK transmitter for large-scale neural recording implants. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2016:6315-6318. [PMID: 28269693 DOI: 10.1109/embc.2016.7592172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In this paper, a short-impulse ultra-wide band (UWB) transmitter is introduced to enable large-scale neural recordings within miniature brain implants including thousands of channels. The proposed impulse radio UWB transmitter uses a BPSK modulation scheme, the carrier signal of which uses only two delayed impulses to encode the transmitted signal. The proposed UWB transmitter has been implemented into a CMOS 180 nm technology. It occupies 300 μm × 230 μm, and consumes only 6.7 pJ/bit from a 1.8-V supply. Experimental results show that the transmitter has a bandwidth of 2.6 GHz to 5.6 GHz and achieves a maximum data rate of 800 Mbps, which outperforms existing low-power UWB transmitters for similar applications.
Collapse
|