Wang W, Wang S, Zhang Y, Geng Y, Li D, Liu S. Multivariable identification based MPC for closed-loop glucose regulation subject to individual variability. Comput Methods Biomech Biomed Engin 2023:1-14. [PMID: 37982220 DOI: 10.1080/10255842.2023.2282952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 11/02/2023] [Indexed: 11/21/2023]
Abstract
The controller is important for the artificial pancreas to guide insulin infusion in diabetic therapy. However, the inter- and intra-individual variability and time delay of glucose metabolism bring challenges to control glucose within a normal range. In this study, a multivariable identification based model predictive control (mi-MPC) is developed to overcome the above challenges. Firstly, an integrated glucose-insulin model is established to describe insulin absorption, glucose-insulin interaction under meal disturbance, and glucose transport. On this basis, an observable glucose-insulin dynamic model is formed, in which the individual parameters and disturbances can be identified by designing a particle filtering estimator. Next, embedded with the identified glucose-insulin dynamic model, a mi-MPC method is proposed. In this controller, plasma glucose concentration (PGC), an important variable and indicator of glucose regulation, is estimated and controlled directly. Finally, the method was tested on 30 in-silico subjects produced by the UVa/Padova simulator. The results show that the mi-MPC method including the model, individual identification, and the controller can regulate glucose with the mean value of 7.45 mmol/L without meal announcement.
Collapse
Affiliation(s)
- Weijie Wang
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, Shanxi, China
- Department of Endocrinology, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Shanxi, China
| | - Shaoping Wang
- School of Automation Science and Electrical Engineering, Beihang University, Beijing, China
- Beijing Advanced Innovation Center for Big Data-based Precision Medicine, Beijing, China
| | - Yuwei Zhang
- School of Automation Science and Electrical Engineering, Beihang University, Beijing, China
| | - Yixuan Geng
- School of Automation Science and Electrical Engineering, Beihang University, Beijing, China
| | - Deng'ao Li
- College of Data Science, Taiyuan University of Technology, Shanxi, China
| | - Shiwei Liu
- Department of Endocrinology, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Shanxi, China
| |
Collapse
|
2
|
Khaqan A, Nauman A, Shuja S, Khurshaid T, Kim KC. An Intelligent Model-Based Effective Approach for Glycemic Control in Type-1 Diabetes. SENSORS (BASEL, SWITZERLAND) 2022; 22:7773. [PMID: 36298123 PMCID: PMC9609843 DOI: 10.3390/s22207773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 09/15/2022] [Accepted: 10/10/2022] [Indexed: 06/16/2023]
Abstract
Type-1 diabetes mellitus (T1DM) is a challenging disorder which essentially involves regulation of the glucose levels to avoid hyperglycemia as well as hypoglycemia. For this purpose, this research paper proposes and develops control algorithms using an intelligent predictive control model, which is based on a UVA/Padova metabolic simulator. The primary objective of the designed control laws is to provide an automatic blood glucose control in insulin-dependent patients so as to improve their life quality and to reduce the need of an extremely demanding self-management plan. Various linear and nonlinear control algorithms have been explored and implemented on the estimated model. Linear techniques include the Proportional Integral Derivative (PID) and Linear Quadratic Regulator (LQR), and nonlinear control strategy includes the Sliding Mode Control (SMC), which are implemented in this research work for continuous monitoring of glucose levels. Performance comparison based on simulation results demonstrated that SMC proved to be most efficient in terms of regulating glucose profile to a reference level of 70 mg/dL compared to the classical linear techniques. A brief comparison is presented between the linear techniques (PID and LQR), and nonlinear technique (SMC) for analysis purposes proving the efficacy of the design.
Collapse
Affiliation(s)
- Ali Khaqan
- Department of Electrical Engineering, COMSATS University Islamabad, Islamabad 45550, Pakistan
| | - Ali Nauman
- Department of Information and Communication Engineering, Yeungnam University, Gyeongsan 38541, Korea
| | - Sana Shuja
- Department of Electrical Engineering, COMSATS University Islamabad, Islamabad 45550, Pakistan
| | - Tahir Khurshaid
- Department of Electrical Engineering, Yeungnam University, Gyeongsan 38541, Korea
| | - Ki-Chai Kim
- Department of Electrical Engineering, Yeungnam University, Gyeongsan 38541, Korea
| |
Collapse
|
3
|
Olçomendy L, Cassany L, Pirog A, Franco R, Puginier E, Jaffredo M, Gucik-Derigny D, Ríos H, Ferreira de Loza A, Gaitan J, Raoux M, Bornat Y, Catargi B, Lang J, Henry D, Renaud S, Cieslak J. Towards the Integration of an Islet-Based Biosensor in Closed-Loop Therapies for Patients With Type 1 Diabetes. Front Endocrinol (Lausanne) 2022; 13:795225. [PMID: 35528003 PMCID: PMC9072637 DOI: 10.3389/fendo.2022.795225] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 02/25/2022] [Indexed: 01/01/2023] Open
Abstract
In diabetes mellitus (DM) treatment, Continuous Glucose Monitoring (CGM) linked with insulin delivery becomes the main strategy to improve therapeutic outcomes and quality of patients' lives. However, Blood Glucose (BG) regulation with CGM is still hampered by limitations of algorithms and glucose sensors. Regarding sensor technology, current electrochemical glucose sensors do not capture the full spectrum of other physiological signals, i.e., lipids, amino acids or hormones, relaying the general body status. Regarding algorithms, variability between and within patients remains the main challenge for optimal BG regulation in closed-loop therapies. This work highlights the simulation benefits to test new sensing and control paradigms which address the previous shortcomings for Type 1 Diabetes (T1D) closed-loop therapies. The UVA/Padova T1DM Simulator is the core element here, which is a computer model of the human metabolic system based on glucose-insulin dynamics in T1D patients. That simulator is approved by the US Food and Drug Administration (FDA) as an alternative for pre-clinical testing of new devices and closed-loop algorithms. To overcome the limitation of standard glucose sensors, the concept of an islet-based biosensor, which could integrate multiple physiological signals through electrical activity measurement, is assessed here in a closed-loop insulin therapy. This investigation has been addressed by an interdisciplinary consortium, from endocrinology to biology, electrophysiology, bio-electronics and control theory. In parallel to the development of an islet-based closed-loop, it also investigates the benefits of robust control theory against the natural variability within a patient population. Using 4 meal scenarios, numerous simulation campaigns were conducted. The analysis of their results then introduces a discussion on the potential benefits of an Artificial Pancreas (AP) system associating the islet-based biosensor with robust algorithms.
Collapse
Affiliation(s)
- Loïc Olçomendy
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Louis Cassany
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Antoine Pirog
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Roberto Franco
- Tecnológico Nacional de México/I.T. La Laguna, Torreón, Mexico
| | | | | | | | - Héctor Ríos
- Tecnológico Nacional de México/I.T. La Laguna, Torreón, Mexico
- Cátedras CONACYT, Ciudad de México, Mexico
| | | | - Julien Gaitan
- Univ. Bordeaux, CNRS, CBMN, UMR 5248, Pessac, France
| | | | - Yannick Bornat
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Bogdan Catargi
- Univ. Bordeaux, CNRS, CBMN, UMR 5248, Pessac, France
- Bordeaux Hospitals, Endocrinology and Metabolic Diseases Unit, Bordeaux, France
| | - Jochen Lang
- Univ. Bordeaux, CNRS, CBMN, UMR 5248, Pessac, France
| | - David Henry
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Sylvie Renaud
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Jérôme Cieslak
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
- *Correspondence: Jérôme Cieslak,
| |
Collapse
|
4
|
Batmani Y, Khodakaramzadeh S. Blood glucose concentration control for type 1 diabetic patients: a multiple-model strategy. IET Syst Biol 2020; 14:24-30. [PMID: 31931478 DOI: 10.1049/iet-syb.2018.5049] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
In this study, a multiple-model strategy is evaluated as an alternative closed-loop method for subcutaneous insulin delivery in type 1 diabetes. Non-linearities of the glucose-insulin regulatory system are considered by modelling the system around five different operating points. After conducting some identification experiments in the UVA/Padova metabolic simulator (accepted simulator by the US Food and Drug Administration (FDA)), five transfer functions are obtained for these operating points. Paying attention to some physiological facts, the control objectives such as the required settling time and permissible bounds of overshoots and undershoots are determined for any transfer functions. Then, five PID controllers are tuned to achieve these objectives and a bank of controllers is constructed. To cope with difficulties of the presence of delays in subcutaneous blood glucose (BG) measuring and in administration of insulin, a glucose-dependent setpoint is considered as the desired trajectory for the BG concentration. The performance of the obtained closed-loop glucose-insulin regulatory system is investigated on the in silico adult cohort of the UVA/Padova metabolic simulator. The obtained results show that the proposed multiple-model strategy leads to a closed-loop mechanism with limited hyperglycemia and no severe hypoglycemia.
Collapse
Affiliation(s)
- Yazdan Batmani
- Department of Electrical Engineering, University of Kurdistan, Sanandaj, Iran.
| | | |
Collapse
|
5
|
Karsaz A. Chattering -free hybrid adaptive neuro-fuzzy inference system-particle swarm optimisation data fusion-based BG-level control. IET Syst Biol 2020; 14:31-38. [PMID: 31931479 DOI: 10.1049/iet-syb.2018.5019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
In this study, a closed-loop control scheme is proposed for the glucose-insulin regulatory system in type-1 diabetic mellitus (T1DM) patients. Some innovative hybrid glucose-insulin regulators have combined artificial intelligence such as fuzzy logic and genetic algorithm with well known Palumbo model to regulate the blood glucose (BG) level in T1DM patients. However, most of these approaches have focused on the glucose reference tracking, and the qualitative of this tracking such as chattering reduction of insulin injection has not been well-studied. Higher-order sliding mode (HoSM) controllers have been employed to attenuate the effect of chattering. Owing to the delayed nature and non-linear property of glucose-insulin mechanism as well as various unmeasurable disturbances, even the HoSM methods are partly successful. In this study, data fusion of adaptive neuro-fuzzy inference systems optimised by particle swarm optimisation has been presented. The excellent performance of the proposed hybrid controller, i.e. desired BG-level tracking and chattering reduction in the presence of daily glucose-level disturbances is verified.
Collapse
Affiliation(s)
- Ali Karsaz
- Department of Electrical and Electronic Engineering, Khorasan Institute of Higher Education, Mashhad, Iran.
| |
Collapse
|
6
|
Automatic blood glucose control for type 1 diabetes: A trade-off between postprandial hyperglycemia and hypoglycemia. Biomed Signal Process Control 2019. [DOI: 10.1016/j.bspc.2019.101603] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
7
|
Mandal S, Sutradhar A. Robust multi-objective blood glucose control in Type-1 diabetic patient. IET Syst Biol 2019; 13:136-146. [PMID: 31170693 PMCID: PMC8687400 DOI: 10.1049/iet-syb.2018.5093] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
In this study, an automatic robust multi‐objective controller has been proposed for blood glucose (BG) regulation in Type‐1 Diabetic Mellitus (T1DM) patient through subcutaneous route. The main objective of this work is to control the BG level in T1DM patient in the presence of unannounced meal disturbances and other external noises with a minimum amount of insulin infusion rate. The multi‐objective output‐feedback controller with H∞, H2 and pole‐placement constraints has been designed using linear matrix inequality technique. The designed controller for subcutaneous insulin delivery was tested on in silico adult and adolescent subjects of UVa/Padova T1DM metabolic simulator. The experimental results show that the closed‐loop system tracks the reference BG level very well and does not show any hypoglycaemia effect even during the long gap of a meal at night both for in silico adults and adolescent. In the presence of 50 gm meal disturbance, average adult experience normoglycaemia 92% of the total simulation time and hypoglycaemia 0% of total simulation time. The robustness of the controller has been tested in the presence of irregular meals and insulin pump noise and error. The controller yielded robust performance with a lesser amount of insulin infusion rate than the other designed controllers reported earlier.
Collapse
Affiliation(s)
- Sharmistha Mandal
- Electrical Engineering Department, Aliah University, Salt Lake, Kolkata, India.
| | - Ashoke Sutradhar
- Electrical Engineering Department, Indian Institute of Engineering Science and Technology, Howrah, India
| |
Collapse
|
8
|
Delavari H, Heydarinejad H, Baleanu D. Adaptive fractional-order blood glucose regulator based on high-order sliding mode observer. IET Syst Biol 2019; 13:43-54. [DOI: 10.1049/iet-syb.2018.5016] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2018] [Revised: 04/24/2018] [Accepted: 06/11/2018] [Indexed: 12/24/2022] Open
|
9
|
Bhattacharjee A, Easwaran A, Leow MKS, Cho N. Design of an online-tuned model based compound controller for a fully automated artificial pancreas. Med Biol Eng Comput 2019; 57:1437-1449. [PMID: 30895514 DOI: 10.1007/s11517-019-01972-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Accepted: 03/06/2019] [Indexed: 11/25/2022]
Abstract
This paper deals with the development of a control algorithm that can predict optimal insulin doses without patients' intervention in fully automated artificial pancreas system. An online-tuned model based compound controller comprising an online-tuned internal model control (IMC) algorithm and an enhanced IMC (eIMC) algorithm along with a meal detection module is proposed. Volterra models, used to develop IMC and eIMC algorithms, are developed online using recursive least squares (RLS) filter. The time domain kernels, computed online using RLS filter, are converted into frequency domain to obtain Volterra transfer function (VTF). VTFs are used to develop both IMC and eIMC algorithms. The compound controller is designed in such a way that eIMC predicts insulin doses when the glucose rate increase detector of meal detection module is positive, otherwise conventional IMC takes the control action. Experimental results show that the compound controller performs robustly in the presence of higher and irregular amounts of meal disturbances at random times, very high actuator and sensor noises and also with the variation in insulin sensitivity. The combination of compound control strategy and meal detection module compensates the shortcomings of both slow subcutaneous insulin action that causes postprandial hyperglycemia, and delayed peak of action that causes hypoglycaemia. Graphical Abstract A fully-automated artificial pancreas system containing glucose sensor, insulin pump and control algorithm. Block diagram showing the control algorithm i.e., online-tuned compound IMC comprising enhanced IMC, conventional IMC and meal detection module, developed in the present work.
Collapse
Affiliation(s)
| | | | - Melvin Khee-Shing Leow
- Nanyang Technological University, Singapore, Singapore.,Department of Endocrinology, Tan Tock Seng Hospital, Singapore, Singapore.,Singapore Institute for Clinical Sciences, A*STAR, Singapore, Singapore.,Office of Clinical Sciences, Duke-NUS Graduate Medical School, Singapore, Singapore.,Lee Kong Chian School of Medicine-Imperial College London, London, SW7 2DD, UK
| | - Namjoon Cho
- Nanyang Technological University, Singapore, Singapore
| |
Collapse
|
10
|
Sánchez-Peña R, Colmegna P, Garelli F, De Battista H, García-Violini D, Moscoso-Vásquez M, Rosales N, Fushimi E, Campos-Náñez E, Breton M, Beruto V, Scibona P, Rodriguez C, Giunta J, Simonovich V, Belloso WH, Cherñavvsky D, Grosembacher L. Artificial Pancreas: Clinical Study in Latin America Without Premeal Insulin Boluses. J Diabetes Sci Technol 2018; 12:914-925. [PMID: 29998754 PMCID: PMC6134619 DOI: 10.1177/1932296818786488] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND Emerging therapies such as closed-loop (CL) glucose control, also known as artificial pancreas (AP) systems, have shown significant improvement in type 1 diabetes mellitus (T1DM) management. However, demanding patient intervention is still required, particularly at meal times. To reduce treatment burden, the automatic regulation of glucose (ARG) algorithm mitigates postprandial glucose excursions without feedforward insulin boluses. This work assesses feasibility of this new strategy in a clinical trial. METHODS A 36-hour pilot study was performed on five T1DM subjects to validate the ARG algorithm. Subjects wore a subcutaneous continuous glucose monitor (CGM) and an insulin pump. Insulin delivery was solely commanded by the ARG algorithm, without premeal insulin boluses. This was the first clinical trial in Latin America to validate an AP controller. RESULTS For the total 36-hour period, results were as follows: average time of CGM readings in range 70-250 mg/dl: 88.6%, in range 70-180 mg/dl: 74.7%, <70 mg/dl: 5.8%, and <50 mg/dl: 0.8%. Results improved analyzing the final 15-hour period of this trial. In that case, the time spent in range was 70-250 mg/dl: 94.7%, in range 70-180 mg/dl: 82.6%, <70 mg/dl: 4.1%, and <50 mg/dl: 0.2%. During the last night the time spent in range was 70-250 mg/dl: 95%, in range 70-180 mg/dl: 87.7%, <70 mg/dl: 5.0%, and <50 mg/dl: 0.0%. No severe hypoglycemia occurred. No serious adverse events were reported. CONCLUSIONS The ARG algorithm was successfully validated in a pilot clinical trial, encouraging further tests with a larger number of patients and in outpatient settings.
Collapse
Affiliation(s)
- Ricardo Sánchez-Peña
- Instituto Tecnológico de Buenos Aires, Buenos Aires, Argentina
- National Scientific and Technical Research Council, Buenos Aires, Argentina
- Ricardo Sánchez-Peña, PhD, National Scientific and Technical Research Council (CONICET), Instituto Tecnológico de Buenos Aires (ITBA), Av Madero 399, Buenos Aires, C1106ACD, Argentina.
| | - Patricio Colmegna
- National Scientific and Technical Research Council, Buenos Aires, Argentina
- University of Virginia, Charlottesville, VA, USA
- Universidad Nacional de Quilmes, Bernal, Buenos Aires, Argentina
| | - Fabricio Garelli
- National Scientific and Technical Research Council, Buenos Aires, Argentina
- Universidad Nacional de La Plata, La Plata, Buenos Aires Argentina
| | - Hernán De Battista
- National Scientific and Technical Research Council, Buenos Aires, Argentina
- Universidad Nacional de La Plata, La Plata, Buenos Aires Argentina
| | - Demián García-Violini
- Instituto Tecnológico de Buenos Aires, Buenos Aires, Argentina
- National Scientific and Technical Research Council, Buenos Aires, Argentina
| | - Marcela Moscoso-Vásquez
- Instituto Tecnológico de Buenos Aires, Buenos Aires, Argentina
- National Scientific and Technical Research Council, Buenos Aires, Argentina
| | - Nicolás Rosales
- Universidad Nacional de La Plata, La Plata, Buenos Aires Argentina
| | - Emilia Fushimi
- National Scientific and Technical Research Council, Buenos Aires, Argentina
- Universidad Nacional de La Plata, La Plata, Buenos Aires Argentina
| | | | - Marc Breton
- University of Virginia, Charlottesville, VA, USA
| | - Valeria Beruto
- Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | - Paula Scibona
- Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | | | - Javier Giunta
- Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | | | | | | | | |
Collapse
|
11
|
Bhattacharjee A, Easwaran A, Leow MKS, Cho N. Evaluation of an artificial pancreas in in silico patients with online-tuned internal model control. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2017.12.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
12
|
Colmegna P, Sánchez-Peña R, Gondhalekar R. Linear parameter-varying model to design control laws for an artificial pancreas. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2017.09.021] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
13
|
Soylu S, Danisman K. In silico testing of optimized Fuzzy P+D controller for artificial pancreas. Biocybern Biomed Eng 2018. [DOI: 10.1016/j.bbe.2018.02.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
14
|
Nath A, Biradar S, Balan A, Dey R, Padhi R. Physiological Models and Control for Type 1 Diabetes Mellitus: A Brief Review. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/j.ifacol.2018.05.077] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
15
|
Cao Z, Gondhalekar R, Dassau E, Doyle FJ. Extremum Seeking Control for Personalized Zone Adaptation in Model Predictive Control for Type 1 Diabetes. IEEE Trans Biomed Eng 2017; 65:1859-1870. [PMID: 29989925 DOI: 10.1109/tbme.2017.2783238] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Zone model predictive control has proven to be an effective closed-loop method to regulate blood glucose for people with type 1 diabetes (T1D). In this paper, we present a universal model-free optimization scheme for adapting the zone for T1D patients individually. The adaptation is based on a clinical glycemic risk index named relative regularized glycemic penalty index (rrGPI), which is calculated from glucose measurements by a continuous glucose monitor. The scheme's objective is to minimize rrGPI by simultaneously modulating a controller's blood glucose target zone's upper bound and lower bound. The adaptation mechanism is based on extremum seeking control, in which the zone boundaries are driven by gradient estimation obtained by continuously sinusoidally modulating and demodulating the rrGPI readings. To improve the adaptation method's robustness against uncertainties, a decaying feedback gain and a vanishing dither signal are employed. in-silico trials suggested that the personalized optimized zone can be reached within a week of adaptation. Both for announced and unannounced meals, the proposed method outperforms the fixed zone [80, 140] mg/dL, which has been employed in the authors' clinical trials. It is also shown that the developed method has strong robustness against real-life uncertainties.
Collapse
|
16
|
Kovács L. Linear parameter varying (LPV) based robust control of type-I diabetes driven for real patient data. Knowl Based Syst 2017. [DOI: 10.1016/j.knosys.2017.02.008] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
17
|
Gondhalekar R, Dassau E, Doyle FJ. Periodic zone-MPC with asymmetric costs for outpatient-ready safety of an artificial pancreas to treat type 1 diabetes . AUTOMATICA : THE JOURNAL OF IFAC, THE INTERNATIONAL FEDERATION OF AUTOMATIC CONTROL 2016; 71:237-246. [PMID: 27695131 PMCID: PMC5040369 DOI: 10.1016/j.automatica.2016.04.015] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
A novel Model Predictive Control (MPC) law for an Artificial Pancreas (AP) to automatically deliver insulin to people with type 1 diabetes is proposed. The MPC law is an enhancement of the authors' zone-MPC approach that has successfully been trialled in-clinic, and targets the safe outpatient deployment of an AP. The MPC law controls blood-glucose levels to a diurnally time-dependent zone, and enforces diurnal, hard input constraints. The main algorithmic novelty is the use of asymmetric input costs in the MPC problem's objective function. This improves safety by facilitating the independent design of the controller's responses to hyperglycemia and hypoglycemia. The proposed controller performs predictive pump-suspension in the face of impending hypoglycemia, and subsequent predictive pump-resumption, based only on clinical needs and feedback. The proposed MPC strategy's benefits are demonstrated by in-silico studies as well as highlights from a US Food and Drug Administration approved clinical trial in which 32 subjects each completed two 25 hour closed-loop sessions employing the proposed MPC law.
Collapse
Affiliation(s)
- Ravi Gondhalekar
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| | - Eyal Dassau
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| | - Francis J. Doyle
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| |
Collapse
|
18
|
Colmegna PH, Sánchez-Peña RS, Gondhalekar R, Dassau E, Doyle FJ. Reducing Glucose Variability Due to Meals and Postprandial Exercise in T1DM Using Switched LPV Control: In Silico Studies. J Diabetes Sci Technol 2016; 10:744-53. [PMID: 27022097 PMCID: PMC5038547 DOI: 10.1177/1932296816638857] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Time-varying dynamics is one of the main issues for achieving safe blood glucose control in type 1 diabetes mellitus (T1DM) patients. In addition, the typical disturbances considered for controller design are meals, which increase the glucose level, and physical activity (PA), which increases the subject's sensitivity to insulin. In previous works the authors have applied a linear parameter-varying (LPV) control technique to manage unannounced meals. METHODS A switched LPV controller that switches between 3 LPV controllers, each with a different level of aggressiveness, is designed to further cope with both unannounced meals and postprandial PA. Thus, the proposed control strategy has a "standard" mode, an "aggressive" mode, and a "conservative" mode. The "standard" mode is designed to be applied most of the time, while the "aggressive" mode is designed to deal only with hyperglycemia situations. On the other hand, the "conservative" mode is focused on postprandial PA control. RESULTS An ad hoc simulator has been developed to test the proposed controller. This simulator is based on the distribution version of the UVA/Padova model and includes the effect of PA based on Schiavon.(1) The test results obtained when using this simulator indicate that the proposed control law substantially reduces the risk of hypoglycemia with the conservative strategy, while the risk of hyperglycemia is scarcely affected. CONCLUSIONS It is demonstrated that the announcement, or anticipation, of exercise is indispensable for letting a mono-hormonal artificial pancreas deal with the consequences of postprandial PA. In view of this the proposed controller allows switching into a conservative mode when notified of PA by the user.
Collapse
Affiliation(s)
- Patricio H Colmegna
- National Scientific and Technical Research Council, Buenos Aires, Argentina Departamento de Ciencia y Tecnología, Universidad Nacional de Quilmes, Buenos Aires, Argentina
| | - Ricardo S Sánchez-Peña
- National Scientific and Technical Research Council, Buenos Aires, Argentina Centro de Sistemas y Control, Instituto Tecnológico de Buenos Aires, Buenos Aires, Argentina
| | - Ravi Gondhalekar
- Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, USA
| | - Eyal Dassau
- John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Francis J Doyle
- John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| |
Collapse
|
19
|
Colmegna PH, Sanchez-Pena RS, Gondhalekar R, Dassau E, Doyle FJ. Switched LPV Glucose Control in Type 1 Diabetes. IEEE Trans Biomed Eng 2015; 63:1192-1200. [PMID: 26452196 DOI: 10.1109/tbme.2015.2487043] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVE The purpose of this paper is to regulate the blood glucose level in Type 1 Diabetes Mellitus patients with a practical and flexible procedure that can switch among a finite number of distinct controllers, depending on the user's choice. METHODS A switched linear parameter-varying controller with multiple switching regions, related to hypo-, hyper-, and euglycemia situations, is designed. The key feature is to arrange the controller into a framework that provides stability and performance guaranty. RESULTS The closed-loop performance is tested on the complete in silico adult cohort of the UVA/Padova metabolic simulator, which has been accepted by the U.S. Food and Drug Administration in lieu of animal trials. The outcome produces comparable or improved results with respect to previous works. CONCLUSION The strategy is practical because it is based on a model tuned only with a priori patient information in order to cover the interpatient uncertainty. Results confirm that this control structure yields tangible improvements in minimizing risks of hyper- and hypoglycemia in scenarios with unannounced meals. SIGNIFICANCE This flexible procedure opens the possibility of taking into account, at the design stage, unannounced meals and/or patients' physical exercise.
Collapse
|