1
|
Ge C, Masalehdan T, Shojaei Baghini M, Duran Toro V, Signorelli L, Thomson H, Gregurec D, Heidari H. Microfabrication Technologies for Nanoinvasive and High-Resolution Magnetic Neuromodulation. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2404254. [PMID: 39445520 PMCID: PMC11633526 DOI: 10.1002/advs.202404254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 09/23/2024] [Indexed: 10/25/2024]
Abstract
The increasing demand for precise neuromodulation necessitates advancements in techniques to achieve higher spatial resolution. Magnetic stimulation, offering low signal attenuation and minimal tissue damage, plays a significant role in neuromodulation. Conventional transcranial magnetic stimulation (TMS), though noninvasive, lacks the spatial resolution and neuron selectivity required for spatially precise neuromodulation. To address these limitations, the next generation of magnetic neurostimulation technologies aims to achieve submillimeter-resolution and selective neuromodulation with high temporal resolution. Invasive and nanoinvasive magnetic neurostimulation are two next-generation approaches: invasive methods use implantable microcoils, while nanoinvasive methods use magnetic nanoparticles (MNPs) to achieve high spatial and temporal resolution of magnetic neuromodulation. This review will introduce the working principles, technical details, coil designs, and potential future developments of these approaches from an engineering perspective. Furthermore, the review will discuss state-of-the-art microfabrication in depth due to its irreplaceable role in realizing next-generation magnetic neuromodulation. In addition to reviewing magnetic neuromodulation, this review will cover through-silicon vias (TSV), surface micromachining, photolithography, direct writing, and other fabrication technologies, supported by case studies, providing a framework for the integration of magnetic neuromodulation and microelectronics technologies.
Collapse
Affiliation(s)
- Changhao Ge
- Microelectronics Lab (meLAB)James Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUK
| | - Tahereh Masalehdan
- Microelectronics Lab (meLAB)James Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUK
| | - Mahdieh Shojaei Baghini
- Microelectronics Lab (meLAB)James Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUK
| | - Vicente Duran Toro
- Biointerfaces lab, Faculty of SciencesFriedrich‐Alexander‐Universität Erlangen‐NürnbergHenkestraße 9191052ErlangenGermany
| | - Lorenzo Signorelli
- Biointerfaces lab, Faculty of SciencesFriedrich‐Alexander‐Universität Erlangen‐NürnbergHenkestraße 9191052ErlangenGermany
| | - Hannah Thomson
- Microelectronics Lab (meLAB)James Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUK
| | - Danijela Gregurec
- Biointerfaces lab, Faculty of SciencesFriedrich‐Alexander‐Universität Erlangen‐NürnbergHenkestraße 9191052ErlangenGermany
| | - Hadi Heidari
- Microelectronics Lab (meLAB)James Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUK
| |
Collapse
|
2
|
Lee AH, Lee J, Leung V, Larson L, Nurmikko A. Patterned electrical brain stimulation by a wireless network of implantable microdevices. Nat Commun 2024; 15:10093. [PMID: 39572612 PMCID: PMC11582589 DOI: 10.1038/s41467-024-54542-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Accepted: 11/12/2024] [Indexed: 11/24/2024] Open
Abstract
Transmitting meaningful information into brain circuits by electronic means is a challenge facing brain-computer interfaces. A key goal is to find an approach to inject spatially structured local current stimuli across swaths of sensory areas of the cortex. Here, we introduce a wireless approach to multipoint patterned electrical microstimulation by a spatially distributed epicortically implanted network of silicon microchips to target specific areas of the cortex. Each sub-millimeter-sized microchip harvests energy from an external radio-frequency source and converts this into biphasic current injected focally into tissue by a pair of integrated microwires. The amplitude, period, and repetition rate of injected current from each chip are controlled across the implant network by implementing a pre-scheduled, collision-free bitmap wireless communication protocol featuring sub-millisecond latency. As a proof-of-concept technology demonstration, a network of 30 wireless stimulators was chronically implanted into motor and sensory areas of the cortex in a freely moving rat for three months. We explored the effects of patterned intracortical electrical stimulation on trained animal behavior at average RF powers well below regulatory safety limits.
Collapse
Affiliation(s)
- Ah-Hyoung Lee
- School of Engineering, Brown University, Providence, RI, USA
| | - Jihun Lee
- School of Engineering, Brown University, Providence, RI, USA
| | - Vincent Leung
- Electrical and Computer Engineering, Baylor University, Waco, TX, USA
| | - Lawrence Larson
- School of Engineering, Brown University, Providence, RI, USA
| | - Arto Nurmikko
- School of Engineering, Brown University, Providence, RI, USA.
- Carney Institute for Brain Science, Brown University, Providence, RI, USA.
| |
Collapse
|
3
|
Kumari P, Wunderlich H, Milojkovic A, López JE, Fossati A, Jahanshahi A, Kozielski K. Multiscale Modeling of Magnetoelectric Nanoparticles for the Analysis of Spatially Selective Neural Stimulation. Adv Healthc Mater 2024; 13:e2302871. [PMID: 38262344 DOI: 10.1002/adhm.202302871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 01/17/2024] [Indexed: 01/25/2024]
Abstract
The growing field of nanoscale neural stimulators offers a potential alternative to larger scale electrodes for brain stimulation. Nanoelectrodes made of magnetoelectric nanoparticles (MENPs) can provide an alternative to invasive electrodes for brain stimulation via magnetic-to-electric signal transduction. However, the magnetoelectric effect is a complex phenomenon and challenging to probe experimentally. Consequently, quantifying the stimulation voltage provided by MENPs is difficult, hindering precise regulation and control of neural stimulation and limiting their practical implementation as wireless nanoelectrodes. The work herein develops an approach to determine the stimulation voltage for MENPs in a finite element analysis (FEA) model. This model is informed by atomistic material properties from ab initio Density Functional Theory (DFT) calculations and supplemented by experimentally obtainable nanoscale parameters. This process overcomes the need for experimentally inaccessible characteristics for magnetoelectricity, and offers insights into the effect of the more manageable variables, such as the driving magnetic field. The model's voltage is compared to in vivo experimental data to assess its validity. With this, a predictable and controllable stimulation is simulated by MENPs, computationally substantiating their spatial selectivity. This work proposes a generalizable and accessible method for evaluating the stimulation capability of magnetoelectric nanostructures, facilitating their realization as wireless neural stimulators in the future.
Collapse
Affiliation(s)
- Prachi Kumari
- Professorship of Neuroengineering Materials, School of Computation, Information and Technology, Technical University of Munich, 80333, Munich, Germany
| | - Hannah Wunderlich
- Professorship of Neuroengineering Materials, School of Computation, Information and Technology, Technical University of Munich, 80333, Munich, Germany
| | - Aleksandra Milojkovic
- Professorship of Neuroengineering Materials, School of Computation, Information and Technology, Technical University of Munich, 80333, Munich, Germany
| | - Jorge Estudillo López
- Professorship of Neuroengineering Materials, School of Computation, Information and Technology, Technical University of Munich, 80333, Munich, Germany
| | - Arianna Fossati
- Department of Electronics and Information, Politecnico di Milano, Milano, 20133, Italy
| | - Ali Jahanshahi
- Department of Neurosurgery, Maastricht University Medical Center, Maastricht, 6229, Netherlands
- Netherlands Institute for Neuroscience, Royal Netherlands Academy of Arts and Sciences, Amsterdam, 1105, Netherlands
| | - Kristen Kozielski
- Professorship of Neuroengineering Materials, School of Computation, Information and Technology, Technical University of Munich, 80333, Munich, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Germany
- Munich Institute of Robotics and Machine Intelligence, Technical University of Munich, 80992, Munich, Germany
| |
Collapse
|
4
|
Choi JH, Moon J, Park YH, Eom K. Computational analysis of electrode structure and configuration for efficient and localized neural stimulation. Biomed Eng Lett 2024; 14:717-726. [PMID: 38946826 PMCID: PMC11208352 DOI: 10.1007/s13534-024-00364-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 01/19/2024] [Accepted: 02/18/2024] [Indexed: 07/02/2024] Open
Abstract
Neuromodulation technique using electric stimulation is widely applied in neural prosthesis, therapy, and neuroscience research. Various stimulation techniques have been developed to enhance stimulation efficiency and to precisely target the specific area of the brain which involves optimizing the geometry and the configuration of the electrode, stimulation pulse type and shapes, and electrode materials. Although the effects of electrode shape, size, and configuration on the performance of neural stimulation have individually been characterized, to date, there is no integrative investigation of how this factor affects neural stimulation. In this study, we computationally modeled the various types of electrodes with varying shapes, sizes, and configurations and simulated the electric field to calculate the activation function. The electrode geometry is then integratively assessed in terms of stimulation efficiency and stimulation focality. We found that stimulation efficiency is enhanced by making the electrode sharper and smaller. A center-to-vertex distance exceeding 100 µm shows enhanced stimulation efficiency in the bipolar configuration. Additionally, the separation distance of less than 1 mm between the reference and stimulation electrodes exhibits higher stimulation efficiency compared to the monopolar configuration. The region of neurons to be stimulated can also be modified. We found that sharper electrodes can locally activate the neuron. In most cases, except for the rectangular electrode shape with a center-to-vertex distance smaller than 100 µm, the bipolar electrode configuration can locally stimulate neurons as opposed to the monopolar configuration. These findings shed light on the optimal selection of neural electrodes depending on the target applications.
Collapse
Affiliation(s)
- Ji Hoon Choi
- Department of Electronics Engineering, College of Engineering, Pusan National University, Busan, 46241 Republic of Korea
| | - Jeongju Moon
- Department of Electronics Engineering, College of Engineering, Pusan National University, Busan, 46241 Republic of Korea
| | - Young Hoon Park
- Department of Electronics Engineering, College of Engineering, Pusan National University, Busan, 46241 Republic of Korea
| | - Kyungsik Eom
- Department of Electronics Engineering, College of Engineering, Pusan National University, Busan, 46241 Republic of Korea
| |
Collapse
|
5
|
Raghuram V, Datye AD, Fried SI, Timko BP. Transparent and Conformal Microcoil Arrays for Spatially Selective Neuronal Activation. DEVICE 2024; 2:100290. [PMID: 39184953 PMCID: PMC11343507 DOI: 10.1016/j.device.2024.100290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/27/2024]
Abstract
Micromagnetic stimulation (μMS) using small, implantable microcoils is a promising method for achieving neuronal activation with high spatial resolution and low toxicity. Herein, we report a microcoil array for localized activation of cortical neurons and retinal ganglion cells. We developed a computational model to relate the electric field gradient (activating function) to the geometry and arrangement of microcoils, and selected a design that produced an anisotropic region of activation <50 μm wide. The device was comprised of an SU-8/Cu/SU-8 tri-layer structure, which was flexible, transparent and conformal and featured four individually-addressable microcoils. Interfaced with cortex or retina explants from GCaMP6-expressing mice, we observed that individual neurons localized within 40 μm of a microcoil tip could be activated repeatedly and in a dose- (power-) dependent fashion. These results demonstrate the potential of μMS devices for brain-machine interfaces and could enable routes toward bioelectronic therapies including prosthetic vision devices.
Collapse
Affiliation(s)
- Vineeth Raghuram
- Dept. of Biomedical Engineering, Tufts University, Medford, MA 02155, USA
- Boston Veterans Affairs Healthcare System, Boston, MA 02130, USA
- Dept. of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA
| | - Aditya D. Datye
- Dept. of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA
| | - Shelley I. Fried
- Dept. of Biomedical Engineering, Tufts University, Medford, MA 02155, USA
- Boston Veterans Affairs Healthcare System, Boston, MA 02130, USA
- Dept. of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA
| | - Brian P. Timko
- Dept. of Biomedical Engineering, Tufts University, Medford, MA 02155, USA
- Lead Contact
| |
Collapse
|
6
|
Ye H, Dima M, Hall V, Hendee J. Cellular mechanisms underlying carry-over effects after magnetic stimulation. Sci Rep 2024; 14:5167. [PMID: 38431662 PMCID: PMC10908793 DOI: 10.1038/s41598-024-55915-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Accepted: 02/28/2024] [Indexed: 03/05/2024] Open
Abstract
Magnetic fields are widely used for neuromodulation in clinical settings. The intended effect of magnetic stimulation is that neural activity resumes its pre-stimulation state right after stimulation. Many theoretical and experimental works have focused on the cellular and molecular basis of the acute neural response to magnetic field. However, effects of magnetic stimulation can still last after the termination of the magnetic stimulation (named "carry-over effects"), which could generate profound effects to the outcome of the stimulation. However, the cellular and molecular mechanisms of carry-over effects are largely unknown, which renders the neural modulation practice using magnetic stimulation unpredictable. Here, we investigated carry-over effects at the cellular level, using the combination of micro-magnetic stimulation (µMS), electrophysiology, and computation modeling. We found that high frequency magnetic stimulation could lead to immediate neural inhibition in ganglion neurons from Aplysia californica, as well as persistent, carry-over inhibition after withdrawing the magnetic stimulus. Carry-over effects were found in the neurons that fired action potentials under a variety of conditions. The carry-over effects were also observed in the neurons when the magnetic field was applied across the ganglion sheath. The state of the neuron, specifically synaptic input and membrane potential fluctuation, plays a significant role in generating the carry-over effects after magnetic stimulation. To elucidate the cellular mechanisms of such carry-over effects under magnetic stimulation, we simulated a single neuron under magnetic stimulation with multi-compartment modeling. The model successfully replicated the carry-over effects in the neuron, and revealed that the carry-over effect was due to the dysfunction of the ion channel dynamics that were responsible for the initiation and sustaining of membrane excitability. A virtual voltage-clamp experiment revealed a compromised Na conductance and enhanced K conductance post magnetic stimulation, rendering the neurons incapable of generating action potentials and, therefore, leading to the carry over effects. Finally, both simulation and experimental results demonstrated that the carry-over effects could be controlled by disturbing the membrane potential during the post-stimulus inhibition period. Delineating the cellular and ion channel mechanisms underlying carry-over effects could provide insights to the clinical outcomes in brain stimulation using TMS and other modalities. This research incentivizes the development of novel neural engineering or pharmacological approaches to better control the carry-over effects for optimized clinical outcomes.
Collapse
Affiliation(s)
- Hui Ye
- Department of Biology, Loyola University Chicago, Quinlan Life Sciences Education and Research Center, 1032 W. Sheridan Rd., Chicago, IL, 60660, USA.
| | - Maria Dima
- Department of Biology, Loyola University Chicago, Quinlan Life Sciences Education and Research Center, 1032 W. Sheridan Rd., Chicago, IL, 60660, USA
| | - Vincent Hall
- Department of Biology, Loyola University Chicago, Quinlan Life Sciences Education and Research Center, 1032 W. Sheridan Rd., Chicago, IL, 60660, USA
| | - Jenna Hendee
- Department of Biology, Loyola University Chicago, Quinlan Life Sciences Education and Research Center, 1032 W. Sheridan Rd., Chicago, IL, 60660, USA
| |
Collapse
|
7
|
Alzahrani M, Roth BJ. The Electric Field Induced by a Microcoil During Magnetic Stimulation. IEEE Trans Biomed Eng 2023; 70:3260-3262. [PMID: 37167044 DOI: 10.1109/tbme.2023.3275098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
OBJECTIVE The purpose of this study is to calculate the electric field produced by an implanted microcoil during magnetic stimulation of the brain. METHODS The electric field of a microcoil was calculated numerically. RESULTS The maximum value of the induced electric field is approximately 0.000026 V/m for a 1 mA, 3 kHz current passed through the coil. CONCLUSION This electric field value is too small to cause neural stimulation. SIGNIFICANCE Previous studies reporting magnetic stimulation using a microcoil must have been exciting neurons by some other mechanism.
Collapse
|
8
|
Whalen AJ, Fried SI. Thermal safety considerations for implantable micro-coil design. J Neural Eng 2023; 20:10.1088/1741-2552/ace79a. [PMID: 37451256 PMCID: PMC10467159 DOI: 10.1088/1741-2552/ace79a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 07/14/2023] [Indexed: 07/18/2023]
Abstract
Micro magnetic stimulation of the brain via implantable micro-coils is a promising novel technology for neuromodulation. Careful consideration of the thermodynamic profile of such devices is necessary for effective and safe designs.Objective.We seek to quantify the thermal profile of bent wire micro-coils in order to understand and mitigate thermal impacts of micro-coil stimulation.Approach. In this study, we use fine wire thermocouples and COMSOL finite element modeling to examine the profile of the thermal gradients generated near bent wire micro-coils submerged in a water bath during stimulation. We tested a range of stimulation parameters previously reported in the literature such as voltage amplitude, stimulus frequency, stimulus repetition rate and coil wire materials.Main results. We found temperature increases ranging from <1 °C to 8.4 °C depending upon the stimulation parameters tested and coil wire materials used. Numerical modeling of the thermodynamics identified hot spots of the highest temperatures along the micro-coil contributing to the thermal gradients and demonstrated that these thermal gradients can be mitigated by the choice of wire conductor material and construction geometry.Significance. ISO standard 14708-1 designates a thermal safety limit of 2 °C temperature increase for active implantable medical devices. By switching the coil wire material from platinum/iridium to gold, our study achieved a 5-6-fold decrease in the thermal impact of coil stimulation. The thermal gradients generated from the gold wire coil were measured below the 2 °C safety limit for all stimulation parameters tested.
Collapse
Affiliation(s)
- Andrew J. Whalen
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Shelley I. Fried
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, USA
- Boston VA Medical Center, Boston, USA
| |
Collapse
|
9
|
Mandeville R, Sanchez B, Johnston B, Bazarek S, Thum JA, Birmingham A, See RHB, Leochico CFD, Kumar V, Dowlatshahi AS, Brown J, Stashuk D, Rutkove SB. A scoping review of current and emerging techniques for evaluation of peripheral nerve health, degeneration, and regeneration: part 1, neurophysiology. J Neural Eng 2023; 20:041001. [PMID: 37279730 DOI: 10.1088/1741-2552/acdbeb] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 06/06/2023] [Indexed: 06/08/2023]
Abstract
Peripheral neuroregeneration research and therapeutic options are expanding exponentially. With this expansion comes an increasing need to reliably evaluate and quantify nerve health. Valid and responsive measures that can serve as biomarkers of the nerve status are essential for both clinical and research purposes for diagnosis, longitudinal follow-up, and monitoring the impact of any intervention. Furthermore, such biomarkers can elucidate regeneration mechanisms and open new avenues for research. Without these measures, clinical decision-making falls short, and research becomes more costly, time-consuming, and sometimes infeasible. As a companion to Part 2, which is focused on non-invasive imaging, Part 1 of this two-part scoping review systematically identifies and critically examines many current and emerging neurophysiological techniques that have the potential to evaluate peripheral nerve health, particularly from the perspective of regenerative therapies and research.
Collapse
Affiliation(s)
- Ross Mandeville
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA 02215, United States of America
| | - Benjamin Sanchez
- Department Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112, United States of America
| | - Benjamin Johnston
- Department of Neurosurgery, Brigham and Women's Hospital, Boston, MA 02115, United States of America
| | - Stanley Bazarek
- Department of Neurosurgery, Brigham and Women's Hospital, Boston, MA 02115, United States of America
| | - Jasmine A Thum
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA 02114, United States of America
| | - Austin Birmingham
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA 02114, United States of America
| | - Reiner Henson B See
- Department of Neurology, Massachusetts General Hospital, Boston, MA 02114, United States of America
| | - Carl Froilan D Leochico
- Department of Physical Medicine and Rehabilitation, St. Luke's Medical Center, Global City, Taguig, The Philippines
- Department of Rehabilitation Medicine, Philippine General Hospital, University of the Philippines Manila, Manila, The Philippines
| | - Viksit Kumar
- Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, United States of America
| | - Arriyan S Dowlatshahi
- Department of Surgery, Beth Israel Deaconess Medical Center, Boston, MA 02215, United States of America
| | - Justin Brown
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA 02114, United States of America
| | - Daniel Stashuk
- Department of Systems Design Engineering, University of Waterloo, Ontario N2L 3G1, Canada
| | - Seward B Rutkove
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA 02215, United States of America
| |
Collapse
|
10
|
Liu X, Whalen AJ, Ryu SB, Lee SW, Fried SI, Kim K, Cai C, Lauritzen M, Bertram N, Chang B, Yu T, Han A. MEMS micro-coils for magnetic neurostimulation. Biosens Bioelectron 2023; 227:115143. [PMID: 36805270 DOI: 10.1016/j.bios.2023.115143] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 02/06/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023]
Abstract
Micro-coil magnetic stimulation of brain tissue presents new challenges for MEMS micro-coil probe fabrication. The main challenges are threefold; (i) low coil resistance for high power efficiency, (ii) low leak current from the probe into the in vitro experimental set-up, (iii) adaptive MEMS process technology because of the dynamic research area, which requires agile design changes. Taking on these challenges, we present a MEMS fabrication process that has three main features; (i) multilayer resist lift-off process to pattern up to 1800-nm-thick metal films, and special care is taken to obtain high conductivity thin-films by physical vapor deposition, and (ii) all micro-coil Al wires are encapsulated in at least 200 nm of ALD alumina and 6-μm-thick parylene C such the leak resistance is high (>210 GΩ), (iii) combining a multi-step DRIE process and maskless photolithography for adaptive design and device fabrication. The entire process requires four lithography steps. Because we avoided SOI wafers and lithography mask fabrication, the design-to-device time is shortened significantly. The resulting probes are 4-mm-long, 60-μm-thick, and down to 150 μm-wide. Selected MEMS coil devices were validated in vivo using mice and compared to previous work.
Collapse
Affiliation(s)
- Xiyuan Liu
- Department of Civil and Mechanical Engineering, Technical University of Denmark, Lyngby, Denmark; Department of Neuroscience, University of Copenhagen, Copenhagen, Denmark
| | - Andrew J Whalen
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Department of Neurosurgery, Yale School of Medicine, New Haven, CT, USA
| | - Sang Baek Ryu
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Seung Woo Lee
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Department of Brain and Cognitive Sciences, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea
| | - Shelley I Fried
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Boston VA Healthcare System, Boston, MA, USA
| | - Kayeon Kim
- Department of Neuroscience, University of Copenhagen, Copenhagen, Denmark
| | - Changsi Cai
- Department of Neuroscience, University of Copenhagen, Copenhagen, Denmark
| | - Martin Lauritzen
- Department of Neuroscience, University of Copenhagen, Copenhagen, Denmark; Department of Clinical Neurophysiology, Rigshospitalet, Copenhagen, Denmark
| | - Nicolas Bertram
- Department of Civil and Mechanical Engineering, Technical University of Denmark, Lyngby, Denmark; Department of Neuroscience, University of Copenhagen, Copenhagen, Denmark
| | - Bingdong Chang
- Department of Civil and Mechanical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Tianbo Yu
- Department of Civil and Mechanical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Anpan Han
- Department of Civil and Mechanical Engineering, Technical University of Denmark, Lyngby, Denmark.
| |
Collapse
|
11
|
Ye H, Hall V, Hendee J. Improving focality and consistency in micromagnetic stimulation. Front Comput Neurosci 2023; 17:1105505. [PMID: 36817316 PMCID: PMC9932264 DOI: 10.3389/fncom.2023.1105505] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 01/17/2023] [Indexed: 02/05/2023] Open
Abstract
The novel micromagnetic stimulation (μMS) technology aims to provide high resolution on neuronal targets. However, consistency of neural activation could be compromised by a lack of surgical accuracy, biological variation, and human errors in operation. We have recently modeled the activation of an unmyelinated axon by a circular micro-coil. Although the coil could activate the axon, its performance sometimes lacked focality and consistency. The site of axonal activation could shift by several experimental factors, including the reversal of the coil current, displacement of the coil, and changes in the intensity of the stimulation. Current clinical practice with transcranial magnetic stimulation (TMS) has suggested that figure-eight coils could provide better performance in magnetic stimulation than circular coils. Here, we estimate the performance of μMS by a figure-eight micro-coil, by exploring the impact of the same experimental factors on its focality and consistency in axonal activation. We derived the analytical expression of the electric field and activating function generated by the figure-eight micro-coil, and estimated the location of axonal activation. Using NEURON modeling of an unmyelinated axon, we found two different types (A and B) of axon activation by the figure-eight micro-coil, mediated by coil currents of reversed direction. Type A activation is triggered by membrane hyperpolarization followed by depolarization; Type B activation is triggered by direct membrane depolarization. Consequently, the two types of stimulation are governed by distinct ion channel mechanisms. In comparison to the circular micro-coil, the figure-eight micro-coil requires significantly less current for axonal activation. Under figure-eight micro-coil stimulation, the site of axonal activation does not change with the reversal of the coil current, displacement of the coil, or changes in the intensity of the stimulation. Ultimately, the figure-eight micro-coil provides a more efficient and consistent site of activation than the circular micro-coil in μMS.
Collapse
|
12
|
Lee SW, Fried SI. Micro-magnetic stimulation of primary visual cortex induces focal and sustained activation of secondary visual cortex. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2022; 380:20210019. [PMID: 35658677 PMCID: PMC11493182 DOI: 10.1098/rsta.2021.0019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Accepted: 10/01/2021] [Indexed: 06/15/2023]
Abstract
Cortical visual prostheses that aim to restore sight to the blind require the ability to create neural activity in the visual cortex. Electric stimulation delivered via microelectrodes implanted in the primary visual cortex (V1) has been the most common approach, although conventional electrodes may not effectively confine activation to focal regions and thus the acuity they create may be limited. Magnetic stimulation from microcoils confines activation to single cortical columns of V1 and thus may prove to be more effective than conventional microelectrodes, but the ability of microcoils to drive synaptic connections has not been explored. Here, we show that magnetic stimulation of V1 using microcoils induces spatially confined activation in the secondary visual cortex (V2) in mouse brain slices. Single-loop microcoils were fabricated using platinum-iridium flat microwires, and their effectiveness was evaluated using calcium imaging and compared with that of monopolar and bipolar electrodes. Our results show that compared to the electrodes, the microcoils better confined activation to a small region in V1. In addition, they produced more precise and sustained activation in V2. The finding that microcoil-based stimulation propagates to higher visual centres raises the possibility that complex visual perception, e.g. that requiring sustained synaptic inputs, may be achievable. This article is part of the theme issue 'Advanced neurotechnologies: translating innovation for health and well-being'.
Collapse
Affiliation(s)
- Seung Woo Lee
- Department of Neurosurgery,
Massachusetts General Hospital and Harvard Medical
School, Boston, MA,
USA
| | - Shelley I. Fried
- Department of Neurosurgery,
Massachusetts General Hospital and Harvard Medical
School, Boston, MA,
USA
- Boston VA
Healthcare System, Boston, MA,
USA
| |
Collapse
|
13
|
Ye H. Finding the Location of Axonal Activation by a Miniature Magnetic Coil. Front Comput Neurosci 2022; 16:932615. [PMID: 35847967 PMCID: PMC9276924 DOI: 10.3389/fncom.2022.932615] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Accepted: 06/03/2022] [Indexed: 11/17/2022] Open
Abstract
Magnetic stimulation for neural activation is widely used in clinical and lab research. In comparison to electric stimulation using an implanted electrode, stimulation with a large magnetic coil is associated with poor spatial specificity and incapability to stimulate deep brain structures. Recent developments in micromagnetic stimulation (μMS) technology mitigates some of these shortcomings. The sub-millimeter coils can be covered with soft, biocompatible material, and chronically implanted. They can provide highly specific neural stimulation in the deep neural structure. Although the μMS technology is expected to provide a precise location of neural stimulation, the exact site of neural activation is difficult to determine. Furthermore, factors that could cause the shifting of the activation site during μMS have not been fully investigated. To estimate the location of axon activation in μMS, we first derived an analytical expression of the activating function, which predicts the location of membrane depolarization in an unmyelinated axon. Then, we developed a multi-compartment, Hodgkin-Huxley (H-H) type of NEURON model of an unmyelinated axon to test the impact of several important coil parameters on the location of axonal activation. The location of axonal activation was dependent on both the parameters of the stimulus and the biophysics properties of the targeted axon during μMS. The activating function analysis predicted that the location of membrane depolarization and activation could shift due to the reversal of the coil current and the change in the coil-axon distance. The NEURON modeling confirmed these predictions. Interestingly, the NEURON simulation further revealed that the intensity of stimulation played a significant role in the activation location. Moderate or strong coil currents activated the axon at different locations, mediated by two distinct ion channel mechanisms. This study reports several experimental factors that could cause a potential shift in the location of neural activation during μMS, which is essential for further development of this novel technology.
Collapse
|
14
|
Lee JI, Seist R, McInturff S, Lee DJ, Brown MC, Stankovic KM, Fried S. Magnetic stimulation allows focal activation of the mouse cochlea. eLife 2022; 11:76682. [PMID: 35608242 PMCID: PMC9177144 DOI: 10.7554/elife.76682] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 05/20/2022] [Indexed: 11/13/2022] Open
Abstract
Cochlear implants (CIs) provide sound and speech sensations for patients with severe to profound hearing loss by electrically stimulating the auditory nerve. While most CI users achieve some degree of open set word recognition under quiet conditions, hearing that utilizes complex neural coding (e.g., appreciating music) has proved elusive, probably because of the inability of CIs to create narrow regions of spectral activation. Several novel approaches have recently shown promise for improving spatial selectivity, but substantial design differences from conventional CIs will necessitate much additional safety and efficacy testing before clinical viability is established. Outside the cochlea, magnetic stimulation from small coils (micro-coils) has been shown to confine activation more narrowly than that from conventional microelectrodes, raising the possibility that coil-based stimulation of the cochlea could improve the spectral resolution of CIs. To explore this, we delivered magnetic stimulation from micro-coils to multiple locations of the cochlea and measured the spread of activation utilizing a multielectrode array inserted into the inferior colliculus; responses to magnetic stimulation were compared to analogous experiments with conventional microelectrodes as well as to responses when presenting auditory monotones. Encouragingly, the extent of activation with micro-coils was ~60% narrower compared to electric stimulation and largely similar to the spread arising from acoustic stimulation. The dynamic range of coils was more than three times larger than that of electrodes, further supporting a smaller spread of activation. While much additional testing is required, these results support the notion that magnetic micro-coil CIs can produce a larger number of independent spectral channels and may therefore improve auditory outcomes. Further, because coil-based devices are structurally similar to existing CIs, fewer impediments to clinical translational are likely to arise.
Collapse
Affiliation(s)
- Jae-Ik Lee
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, United States
| | - Richard Seist
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, Boston, United States.,Department of Otorhinolaryngology - Head and Neck Surgery, Paracelsus Medical University, Salzburg, Austria
| | - Stephen McInturff
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, Boston, United States.,Program in Speech and Hearing Bioscience and Technology, Harvard Medical School, Boston, United States
| | - Daniel J Lee
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, Boston, United States.,Program in Speech and Hearing Bioscience and Technology, Harvard Medical School, Boston, United States
| | - M Christian Brown
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, Boston, United States.,Program in Speech and Hearing Bioscience and Technology, Harvard Medical School, Boston, United States
| | - Konstantina M Stankovic
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, Boston, United States.,Program in Speech and Hearing Bioscience and Technology, Harvard Medical School, Boston, United States.,Department of Otolaryngology - Head and Neck Surgery, Stanford University School of Medicine, Stanford, United States
| | - Shelley Fried
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, United States.,Boston VA Medical Center, Boston, United States
| |
Collapse
|
15
|
Saha R, Wu K, Bloom RP, Liang S, Tonini D, Wang JP. A review on magnetic and spintronic neurostimulation: challenges and prospects. NANOTECHNOLOGY 2022; 33:182004. [PMID: 35013010 DOI: 10.1088/1361-6528/ac49be] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Accepted: 01/10/2022] [Indexed: 06/14/2023]
Abstract
In the treatment of neurodegenerative, sensory and cardiovascular diseases, electrical probes and arrays have shown quite a promising success rate. However, despite the outstanding clinical outcomes, their operation is significantly hindered by non-selective control of electric fields. A promising alternative is micromagnetic stimulation (μMS) due to the high permeability of magnetic field through biological tissues. The induced electric field from the time-varying magnetic field generated by magnetic neurostimulators is used to remotely stimulate neighboring neurons. Due to the spatial asymmetry of the induced electric field, high spatial selectivity of neurostimulation has been realized. Herein, some popular choices of magnetic neurostimulators such as microcoils (μcoils) and spintronic nanodevices are reviewed. The neurostimulator features such as power consumption and resolution (aiming at cellular level) are discussed. In addition, the chronic stability and biocompatibility of these implantable neurostimulator are commented in favor of further translation to clinical settings. Furthermore, magnetic nanoparticles (MNPs), as another invaluable neurostimulation material, has emerged in recent years. Thus, in this review we have also included MNPs as a remote neurostimulation solution that overcomes physical limitations of invasive implants. Overall, this review provides peers with the recent development of ultra-low power, cellular-level, spatially selective magnetic neurostimulators of dimensions within micro- to nano-range for treating chronic neurological disorders. At the end of this review, some potential applications of next generation neuro-devices have also been discussed.
Collapse
Affiliation(s)
- Renata Saha
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America
| | - Kai Wu
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America
| | - Robert P Bloom
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America
| | - Shuang Liang
- Department of Chemical Engineering and Material Science, University of Minnesota, Minneapolis, MN 55455, United States of America
| | - Denis Tonini
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America
| | - Jian-Ping Wang
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America
| |
Collapse
|
16
|
Saha R, Faramarzi S, Bloom R, Benally OJ, Wu K, di Girolamo A, Tonini D, Keirstead SA, Low WC, Netoff T, Wang JP. Strength-frequency curve for micromagnetic neurostimulation through excitatory postsynaptic potentials (EPSPs) on rat hippocampal neurons and numerical modeling of magnetic microcoil (μcoil). J Neural Eng 2022; 19. [PMID: 35030549 DOI: 10.1088/1741-2552/ac4baf] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 01/14/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE The objective of this study was to measure the effect of micromagnetic stimulation (μMS) on hippocampal neurons, by using single microcoil (μcoil) prototype, Magnetic Pen (MagPen). MagPen will be used to stimulate the CA3 magnetically and excitatory post synaptic potential (EPSP) measurements will be made from the CA1. The threshold for μMS as a function of stimulation frequency of the current driving the µcoil will be demonstrated. Finally, the optimal stimulation frequency of the current driving the μcoil to minimize power will be estimated. APPROACH A biocompatible prototype, MagPen was built, and customized such that it is easy to adjust the orientation of the μcoil over the hippocampal tissue in an in vitro setting. Finite element modeling (FEM) of the μcoil was performed to estimate the spatial profiles of the magnetic flux density (in T) and the induced electric fields (in V/m). The induced electric field profiles generated at different values of current applied to the µcoil whether can elicit a neuron response was validated by numerical modeling. The modeling settings were replicated in experiments on rat hippocampal neurons. MAIN RESULTS The preferred orientation of MagPen over the Schaffer Collateral fibers was demonstrated such that they elicit a neuron response. The recorded EPSPs from CA1 due to μMS at CA3 were validated by applying tetrodotoxin (TTX). Finally, it was interpreted through numerical analysis that increasing frequency of the current driving the μcoil, led to a decrease in the current amplitude threshold for μMS. SIGNIFICANCE This work reports that μMS can be used to evoke population EPSPs in the CA1 of hippocampus. It demonstrates the strength-frequency curve for µMS and its unique features related to orientation dependence of the µcoils, spatial selectivity and distance dependence. Finally, the challenges related to µMS experiments were studied including ways to overcome them.
Collapse
Affiliation(s)
- Renata Saha
- Electrical and Computer Engineering, University of Minnesota Twin Cities, 200 Union Street SE, Kenneth Keller Hall, Rm 6-147D, Minneapolis, Minnesota, 55455, UNITED STATES
| | - Sadegh Faramarzi
- Department of Biomedical Engineering, University of Minnesota Twin Cities, Nils Hasselmo Hall,, 312 Church St SE,, Minneapolis, Minnesota, 55455, UNITED STATES
| | - Robert Bloom
- Department of Electrical and Computer Engineering, University of Minnesota, 200 Union Street SE, 4-174 Keller Hall, Minneapolis, Minneapolis, Minnesota, 55455, UNITED STATES
| | - Onri J Benally
- Department of Electrical and Computer Engineering, University of Minnesota Twin Cities, 200 Union Street SE,, Kenneth Keller Hall, Minneapolis, Minnesota, 55455, UNITED STATES
| | - Kai Wu
- Electrical and Computer Engineering, University of Minnesota Twin Cities, 200 Union Street SE, Minneapolis, Minnesota, 55455, UNITED STATES
| | - Arturo di Girolamo
- Department of Electrical and Computer Engineering, University of Minnesota Twin Cities, 200 Union Street SE, Kenneth Keller Hall, Minneapolis, Minnesota, 55455, UNITED STATES
| | - Denis Tonini
- Department of Electrical and Computer Engineering, University of Minnesota Twin Cities, 200 Union Street SE,, Kenneth Keller Hall, Minneapolis, Minnesota, 55455, UNITED STATES
| | - Susan A Keirstead
- Department of Integrative Biology & Physiology, University of Minnesota Twin Cities, Stem Cell Institute, LRB/MTRF 2873B (Campus Delivery Code), 2001 6th St SE, Minneapolis, Minnesota, 55455, UNITED STATES
| | - Walter C Low
- Department of Neurosurgery, University of Minnesota Twin Cities, LRB/MTRF 2873J (Campus Delivery Code), 2001 6th St SE, Minneapolis, Minnesota, 55455, UNITED STATES
| | - Theoden Netoff
- Department of Biomedical Engineering, University of Minnesota Twin Cities, 312 Church Street SE, 7-105 Nils Hasselmo Hall, Minneapolis, Minnesota, 55455, UNITED STATES
| | - Jian-Ping Wang
- Department of Electrical and Computer Engineering, University of Minnesota Twin Cities, 200 Union Street SE, Kenneth Keller Hall, Minneapolis, Minnesota, 55455, UNITED STATES
| |
Collapse
|
17
|
Yang X, McGlynn E, Das R, Paşca SP, Cui B, Heidari H. Nanotechnology Enables Novel Modalities for Neuromodulation. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2103208. [PMID: 34668249 PMCID: PMC8712412 DOI: 10.1002/adma.202103208] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 06/27/2021] [Indexed: 05/18/2023]
Abstract
Neuromodulation is of great importance both as a fundamental neuroscience research tool for analyzing and understanding the brain function, and as a therapeutic avenue for treating brain disorders. Here, an overview of conceptual and technical progress in developing neuromodulation strategies is provided, and it is suggested that recent advances in nanotechnology are enabling novel neuromodulation modalities with less invasiveness, improved biointerfaces, deeper penetration, and higher spatiotemporal precision. The use of nanotechnology and the employment of versatile nanomaterials and nanoscale devices with tailored physical properties have led to considerable research progress. To conclude, an outlook discussing current challenges and future directions for next-generation neuromodulation modalities is presented.
Collapse
Affiliation(s)
- Xiao Yang
- Department of Psychiatry and Behavioral SciencesStanford UniversityStanfordCA94305USA
- Stanford Brain OrganogenesisWu Tsai Neurosciences InstituteStanford UniversityStanfordCA94305USA
- Wu Tsai Neurosciences InstituteStanford UniversityStanfordCA94305USA
- Department of ChemistryStanford UniversityStanfordCA94305USA
| | - Eve McGlynn
- Microelectronics Lab (meLAB)James Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUK
| | - Rupam Das
- Microelectronics Lab (meLAB)James Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUK
| | - Sergiu P. Paşca
- Department of Psychiatry and Behavioral SciencesStanford UniversityStanfordCA94305USA
- Stanford Brain OrganogenesisWu Tsai Neurosciences InstituteStanford UniversityStanfordCA94305USA
| | - Bianxiao Cui
- Wu Tsai Neurosciences InstituteStanford UniversityStanfordCA94305USA
- Department of ChemistryStanford UniversityStanfordCA94305USA
| | - Hadi Heidari
- Microelectronics Lab (meLAB)James Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUK
| |
Collapse
|
18
|
Le HT, Haque RI, Ouyang Z, Lee SW, Fried SI, Zhao D, Qiu M, Han A. MEMS inductor fabrication and emerging applications in power electronics and neurotechnologies. MICROSYSTEMS & NANOENGINEERING 2021; 7:59. [PMID: 34567771 PMCID: PMC8433479 DOI: 10.1038/s41378-021-00275-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 05/04/2021] [Accepted: 05/10/2021] [Indexed: 05/08/2023]
Abstract
MEMS inductors are used in a wide range of applications in micro- and nanotechnology, including RF MEMS, sensors, power electronics, and Bio-MEMS. Fabrication technologies set the boundary conditions for inductor design and their electrical and mechanical performance. This review provides a comprehensive overview of state-of-the-art MEMS technologies for inductor fabrication, presents recent advances in 3D additive fabrication technologies, and discusses the challenges and opportunities of MEMS inductors for two emerging applications, namely, integrated power electronics and neurotechnologies. Among the four top-down MEMS fabrication approaches, 3D surface micromachining and through-substrate-via (TSV) fabrication technology have been intensively studied to fabricate 3D inductors such as solenoid and toroid in-substrate TSV inductors. While 3D inductors are preferred for their high-quality factor, high power density, and low parasitic capacitance, in-substrate TSV inductors offer an additional unique advantage for 3D system integration and efficient thermal dissipation. These features make in-substrate TSV inductors promising to achieve the ultimate goal of monolithically integrated power converters. From another perspective, 3D bottom-up additive techniques such as ice lithography have great potential for fabricating inductors with geometries and specifications that are very challenging to achieve with established MEMS technologies. Finally, we discuss inspiring and emerging research opportunities for MEMS inductors.
Collapse
Affiliation(s)
- Hoa Thanh Le
- The Rowland Institute at Harvard, Harvard University, Cambridge, MA USA
| | - Rubaiyet I. Haque
- Department of Mechanical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Ziwei Ouyang
- Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Seung Woo Lee
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA USA
| | - Shelley I. Fried
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA USA
- Boston VA Healthcare System, Boston, MA USA
| | - Ding Zhao
- Key Laboratory of 3D Micro/Nano Fabrication and Characterization of Zhejiang Province, School of Engineering, Westlake University, Hangzhou, China
- Institute of Advanced Technology, Westlake Institute for Advanced Study, Hangzhou, China
| | - Min Qiu
- Key Laboratory of 3D Micro/Nano Fabrication and Characterization of Zhejiang Province, School of Engineering, Westlake University, Hangzhou, China
- Institute of Advanced Technology, Westlake Institute for Advanced Study, Hangzhou, China
| | - Anpan Han
- Department of Mechanical Engineering, Technical University of Denmark, Lyngby, Denmark
| |
Collapse
|
19
|
Thyagarajan K, Lujan RA, Wang Q, Lu J, Kor S, Kakimoto B, Chang N, Bert JA. Micro-coil probes for magnetic intracortical neural stimulation: Trade-offs in materials and design. APL MATERIALS 2021; 9:011102. [PMID: 33520428 PMCID: PMC7808331 DOI: 10.1063/5.0023486] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Accepted: 12/20/2020] [Indexed: 05/04/2023]
Abstract
Neural probes for intracortical neuromodulation in the brain have advanced with the developments in micro- and nanofabrication technologies. Most of these technologies for the intracortical stimulation have relied on the direct electrical stimulation via electrodes or arrays of electrodes. Generating electric fields using time-varying magnetic fields is a more recent neuromodulation technique that has proven to be more specifically effective for the intracortical stimulation. Additionally, current-actuated coils require no conductive contact with tissues and enable precise tailoring of magnetic fields, which are unaffected by the non-magnetic nature of the biological tissue and encapsulation layers. The material and design parameter space for such micro-coil fabrication can be optimized and tailored to deliver the ideal performance depending on the parameters needed for operation. In this work, we review the key requirements for implantable microcoils including the probe structure and material properties and discuss their characteristics and related challenges for the applications in intracortical neuromodulation.
Collapse
|
20
|
Cho Y, Park J, Lee C, Lee S. Recent progress on peripheral neural interface technology towards bioelectronic medicine. Bioelectron Med 2020; 6:23. [PMID: 33292861 PMCID: PMC7706233 DOI: 10.1186/s42234-020-00059-z] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 11/05/2020] [Indexed: 11/23/2022] Open
Abstract
Modulation of the peripheral nervous system (PNS) has a great potential for therapeutic intervention as well as restore bodily functions. Recent interest has focused on autonomic nerves, as they regulate extensive functions implicated in organ physiology, chronic disease state and appear tractable to targeted modulation of discrete nerve units. Therapeutic interventions based on specific bioelectronic neuromodulation depend on reliable neural interface to stimulate and record autonomic nerves. Furthermore, the function of stimulation and recording requires energy which should be delivered to the interface. Due to the physiological and anatomical challenges of autonomic nerves, various forms of this active neural interface need to be developed to achieve next generation of neural interface for bioelectronic medicine. In this article, we present an overview of the state-of-the-art for peripheral neural interface technology in relation to autonomic nerves. Also, we reveal the current status of wireless neural interface for peripheral nerve applications. Recent studies of a novel concept of self-sustainable neural interface without battery and electronic components are presented. Finally, the recent results of non-invasive stimulation such as ultrasound and magnetic stimulation are covered and the perspective of the future research direction is provided.
Collapse
Affiliation(s)
- Youngjun Cho
- Daegu Geongbuk Institute of Science and Technology (DGIST), Daegu, 42899, Republic of Korea
| | - Jaeu Park
- Daegu Geongbuk Institute of Science and Technology (DGIST), Daegu, 42899, Republic of Korea
| | - Chengkuo Lee
- Electrical & Computer Engineering, National University of Singapore, Singapore, 117583, Singapore. .,Center for Intelligent Sensors and MEMS (CISM), National University of Singapore, Singapore, 117608, Singapore. .,NUS Graduate School for Integrated Science and Engineering (NGS), National University of Singapore, Singapore, 117456, Singapore.
| | - Sanghoon Lee
- Daegu Geongbuk Institute of Science and Technology (DGIST), Daegu, 42899, Republic of Korea.
| |
Collapse
|
21
|
Lee SW. Selective Activation of Cortical Columns Using Multichannel Magnetic Stimulation With a Bent Flat Microwire Array. IEEE Trans Biomed Eng 2020; 68:2164-2175. [PMID: 33095707 DOI: 10.1109/tbme.2020.3033491] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Cortical neural prostheses that aim to restore useful vision, hearing, and tactile sensations require the ability to selectively target different cortical regions simultaneously. Electrical stimulation via intracortical electrodes has been used to create spatial patterns of cortical activation. However, their efficacy remains limited due to the inability of conventional electrodes to confine activation to specific cortical regions around each electrode. Magnetic stimulation from single bent wires can selectively activate pyramidal neurons while avoiding passing axons, thereby confining activation to small cortical regions. This paper presents a novel bent flat microwire array and demonstrates its effectiveness for selective activation of cortical columns in mouse brain slices. METHODS A computational model was developed to compare the spatial resolution of magnetic stimulation from bent wire arrays with 280 and 530 μm tip spacings. The same array designs were fabricated for use in electrophysiological experiments, i.e., calcium imaging (GCaMP6s) of mouse brain slices. RESULTS All fabricated array designs reliably produced spatially discrete cortical activations at low stimulus amplitudes, but the 280-μm-spacing produced strong interference (constructive or destructive) at high stimulus amplitudes, thereby resulting in single strong activations or two asymmetric activations. 4-channel bent wire arrays with spacing of 340 μm avoided the interference and produced clearer spatial patterns of activation than electrodes. CONCLUSION Bent wire array designs can influence the strength or the spatial resolution of multichannel magnetic stimulation. SIGNIFICANCE These results suggest that bent microwire arrays can enhance the selectivity of multichannel stimulation of brain and therefore may help to develop reliable and effective cortical neural prostheses.
Collapse
|
22
|
Ryu SB, Paulk AC, Yang JC, Ganji M, Dayeh SA, Cash SS, Fried SI, Lee SW. Spatially confined responses of mouse visual cortex to intracortical magnetic stimulation from micro-coils. J Neural Eng 2020; 17:056036. [PMID: 32998116 PMCID: PMC8923513 DOI: 10.1088/1741-2552/abbd22] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Electrical stimulation via microelectrodes implanted in cortex has been suggested as a potential treatment for a wide range of neurological disorders. Despite some success however, the effectiveness of conventional electrodes remains limited, in part due to an inability to create specific patterns of neural activity around each electrode and in part due to challenges with maintaining a stable interface. The use of implantable micro-coils to magnetically stimulate the cortex has the potential to overcome these limitations because the asymmetric fields from coils can be harnessed to selectively activate some neurons, e.g. vertically-oriented pyramidal neurons while avoiding others, e.g. horizontally-oriented passing axons. In vitro experiments have shown that activation is indeed confined with micro-coils but their effectiveness in the intact brain of living animals has not been evaluated. APPROACH To assess the efficacy of stimulation, a 128-channel custom recording microelectrode array was positioned on the surface of the visual cortex (ECoG) in anesthetized mice and responses to magnetic and electric stimulation were compared. Stimulation was delivered from electrodes or micro-coils implanted through a hole in the center of the recording array at a rate of 200 pulses per second for 100 ms. MAIN RESULTS Both electric and magnetic stimulation reliably elicited cortical responses, although activation from electric stimulation was spatially expansive, often extending more than 1 mm from the stimulation site, while activation from magnetic stimulation was typically confined to a ∼300 µm diameter region around the stimulation site. Results were consistent for stimulation of both cortical layer 2/3 and layer 5 as well as across a range of stimulus strengths. SIGNIFICANCE The improved focality with magnetic stimulation suggests that the effectiveness of cortical stimulation can be improved. Improved focality may be particularly attractive for cortical prostheses that require high spatial resolution, e.g. devices that target sensory cortex, as it may lead to improved acuity.
Collapse
Affiliation(s)
- Sang Baek Ryu
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Angelique C. Paulk
- Department of Neurology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Jimmy C. Yang
- Department of Neurology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Mehran Ganji
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, USA
| | - Shadi A. Dayeh
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, USA
| | - Sydney S. Cash
- Department of Neurology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Shelley I. Fried
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Boston VA Healthcare System, Boston, MA, USA
| | - Seung Woo Lee
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|