1
|
Hosur S, Kashani Z, Karan SK, Priya S, Kiani M. MagSonic: Hybrid Magnetic-Ultrasonic Wireless Interrogation of Millimeter-Scale Biomedical Implants With Magnetoelectric Transducer. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:383-395. [PMID: 37976195 DOI: 10.1109/tbcas.2023.3334166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
Wireless interrogation (power and data transfer) of biomedical implants, miniaturized to millimeter (mm) dimensions, is critical for their chronic operation. Achieving simultaneous wireless power and data transfer at deep sites reliably within safety limits for closed-loop sensing/actuation functions of mm-sized implants is challenging. To enable this operation, a hybrid magnetic-ultrasonic interrogation approach (called MagSonic) is realized through a single magnetoelectric (ME) transducer at the implant that can generate and receive both magnetic field and ultrasound. The fabricated mm-sized bar-shaped ME transducer (5.2×2×1.6 mm3) operates at acoustic wave resonance, functioning at sub-MHz frequencies. For the first time, we demonstrate wireless power reception through one modality (magnetic field or ultrasound) and simultaneous uplink data transmission using the other. At 40 mm depth, the MagSonic link could achieve 100 kbps uplink data rate (bit error rate ≤ 10-5) using 190 pJ/bit transmitted energy and 8 mW delivered power in tissue. The robustness of the MagSonic interrogation link against power carrier interference and misalignments is also demonstrated.
Collapse
|
2
|
Namgoong G, Park W, Bien F. A 13.56 MHz Wireless Power Transfer System With Fully Integrated PLL-Based Frequency-Regulated Reconfigurable Duty Control for Implantable Medical Devices. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:1116-1128. [PMID: 36223350 DOI: 10.1109/tbcas.2022.3213817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
In this paper, a 13.56 MHz wireless power transfer system with transmitter (TX) and receiver (RX) chips is presented. Both TX and RX chips were designed with fully integrated reconfigurable single power stage to realize adaptive power delivery and output voltage regulation. The reconfigurable operation of TX and RX is synchronized and the reconfiguration frequency which could vary with coupling or loading condition is locked by the proposed phase-locked-loop-based on-time duty controller to mitigate the electromagnetic interference. In addition, calibrations for circuit delay and power switch size were implemented in the RX chip to enhance system efficiency further. The system complexity is reduced considerably by removing the successive power stages and off-chip controllers used in previous studies. The TX and RX chips were fabricated in TSMC 0.18 μm CMOS process. The measurement results demonstrated seamless output voltage regulation under an output power range from 4.2 mW to 162 mW and a peak end-to-end efficiency of 70.1%.
Collapse
|
3
|
Hossain ANMS, Mohseni P, Lavasani HM. Design and Optimization of Capacitive Links for Wireless Power Transfer to Biomedical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:1299-1312. [PMID: 36215337 DOI: 10.1109/tbcas.2022.3213000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
This paper provides a comprehensive overview of capacitive wireless power transfer (C-WPT) links for biomedical implants, and proposes an algorithmic approach to optimize their design for a theoretically feasible desired power transmission efficiency (PTE). Two C-WPT links, one involving external inductors for parasitic capacitance cancellation, and another without external inductors are presented. An accurate electrical model has been presented for both cases considering the finite conductivity of the body tissue and fringe fields emanated from the metallic plates. Ex-vivo experiments were conducted with beef tissue to demonstrate the viability of the model and the optimization algorithm. The analytical and simulation results show good agreement with the measurement (with real tissue) for both types of links across a wide range of operating frequency, including one with the highest reported frequency (∼14.6 MHz) among tuned links.
Collapse
|
4
|
Habibagahi I, Omidbeigi M, Hadaya J, Lyu H, Jang J, Ardell JL, Bari AA, Babakhani A. Vagus nerve stimulation using a miniaturized wirelessly powered stimulator in pigs. Sci Rep 2022; 12:8184. [PMID: 35581302 PMCID: PMC9114380 DOI: 10.1038/s41598-022-11850-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Accepted: 04/26/2022] [Indexed: 11/09/2022] Open
Abstract
Neuromodulation of peripheral nerves has been clinically used for a wide range of indications. Wireless and batteryless stimulators offer important capabilities such as no need for reoperation, and extended life compared to their wired counterparts. However, there are challenging trade-offs between the device size and its operating range, which can limit their use. This study aimed to examine the functionality of newly designed wirelessly powered and controlled implants in vagus nerve stimulation for pigs. The implant used near field inductive coupling at 13.56 MHz industrial, scientific, and medical band to harvest power from an external coil. The circular implant had a diameter of 13 mm and weighed 483 mg with cuff electrodes. The efficiency of the inductive link and robustness to distance and misalignment were optimized. As a result, the specific absorption rate was orders of magnitude lower than the safety limit, and the stimulation can be performed using only 0.1 W of external power. For the first time, wireless and batteryless VNS with more than 5 cm operation range was demonstrated in pigs. A total of 84 vagus nerve stimulations (10 s each) have been performed in three adult pigs. In a quantitative comparison of the effectiveness of VNS devices, the efficiency of systems on reducing heart rate was similar in both conventional (75%) and wireless (78.5%) systems. The pulse width and frequency of the stimulation were swept on both systems, and the response for physiological markers was drawn. The results were easily reproducible, and methods used in this study can serve as a basis for future wirelessly powered implants.
Collapse
Affiliation(s)
- Iman Habibagahi
- Electrical and Computer Engineering Department, University of California Los Angeles, Los Angeles, CA, USA.
| | - Mahmoud Omidbeigi
- Department of Neurosurgery, University of California at Los Angeles, Los Angeles, CA, USA.
| | - Joseph Hadaya
- UCLA Cardiac Arrhythmia Center, University of California Los Angeles, Los Angeles, CA, USA.,UCLA Neurocardiology Research Program of Excellence, University of California Los Angeles, Los Angeles, CA, USA.,Molecular, Cellular and Integrative Physiology Program, University of California Los Angeles, Los Angeles, CA, USA
| | - Hongming Lyu
- Electrical and Computer Engineering Department, University of California Los Angeles, Los Angeles, CA, USA
| | - Jaeeun Jang
- Electrical and Computer Engineering Department, University of California Los Angeles, Los Angeles, CA, USA
| | - Jeffrey L Ardell
- UCLA Cardiac Arrhythmia Center, University of California Los Angeles, Los Angeles, CA, USA.,UCLA Neurocardiology Research Program of Excellence, University of California Los Angeles, Los Angeles, CA, USA
| | - Ausaf A Bari
- Department of Neurosurgery, University of California at Los Angeles, Los Angeles, CA, USA
| | - Aydin Babakhani
- Electrical and Computer Engineering Department, University of California Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
5
|
Nikić M, Opančar A, Hartmann F, Migliaccio L, Jakešová M, Głowacki ED, Đerek V. Micropyramid structured photo capacitive interfaces. NANOTECHNOLOGY 2022; 33:245302. [PMID: 35226885 DOI: 10.1088/1361-6528/ac5927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 02/28/2022] [Indexed: 06/14/2023]
Abstract
Optically driven electronic neuromodulation devices are a novel tool in basic research and offer new prospects in medical therapeutic applications. Optimal operation of such devices requires efficient light capture and charge generation, effective electrical communication across the device's bioelectronic interface, conformal adhesion to the target tissue, and mechanical stability of the device during the lifetime of the implant-all of which can be tuned by spatial structuring of the device. We demonstrate a 3D structured opto-bioelectronic device-an organic electrolytic photocapacitor spatially designed by depositing the active device layers on an inverted micropyramid-shaped substrate. Ultrathin, transparent, and flexible micropyramid-shaped foil was fabricated by chemical vapour deposition of parylene C on silicon moulds containing arrays of inverted micropyramids, followed by a peel-off procedure. The capacitive current delivered by the devices showed a strong dependency on the underlying spatial structure. The device performance was evaluated by numerical modelling. We propose that the developed numerical model can be used as a basis for the design of future functional 3D design of opto-bioelectronic devices and electrodes.
Collapse
Affiliation(s)
- Marta Nikić
- Department of Physics, Faculty of Science, University of Zagreb, Bijenička c. 32, 10000, Zagreb, Croatia
| | - Aleksandar Opančar
- Department of Physics, Faculty of Science, University of Zagreb, Bijenička c. 32, 10000, Zagreb, Croatia
| | - Florian Hartmann
- Soft Matter Physics, Institute of Experimental Physics, Johannes Kepler University Linz, Altenberger Strasse 69, Linz, A-4040, Austria
- Soft Materials Lab, Linz Institute of Technology LIT, Johannes Kepler University, Altenberger Strasse 69, Linz, A-4040, Austria
| | - Ludovico Migliaccio
- Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200 Brno, Czech Republic
| | - Marie Jakešová
- Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200 Brno, Czech Republic
| | - Eric Daniel Głowacki
- Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200 Brno, Czech Republic
| | - Vedran Đerek
- Department of Physics, Faculty of Science, University of Zagreb, Bijenička c. 32, 10000, Zagreb, Croatia
| |
Collapse
|
6
|
Hossain ANMS, Erfani R, Mohseni P, Lavasani HM. On the Non-idealities of a Capacitive Link for Wireless Power Transfer to Biomedical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:314-325. [PMID: 33784624 DOI: 10.1109/tbcas.2021.3069842] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
This paper studies the performance of a resonant capacitive wireless power transfer (C-WPT) link for biomedical implants in the presence of non-idealities. The study emphasizes on finding an accurate electrical model of a practical C-WPT link, which can be used to investigate the performance of the link under different practical/non-ideal scenarios. A sound knowledge about these non-idealities is crucial for device optimization. For the first time, a circuit model has been presented and analyzed, which is applicable to a practical C-WPT link undergoing plate mismatch, flexion, tissue contraction, and stretching. Our model considers the finite conductivity of the body tissue and fringe fields formed by capacitor plates. Analytical and HFSSTM simulation results have been presented for different non-idealities, and are in good agreement. Additionally, we show a procedure to interpolate non-ideal case results. The study shows that plate misalignment (causing reduction in parallel plate overlap area) and skin tissue contraction (while muscle grows) are the most detrimental individual factors to the link performance. We recorded ∼32% and ∼14% power transfer efficiency decrease due to these two worst-case scenarios, respectively for a C-WPT link comprising of two pairs of 400 mm2 parallel plates (12 cm edge-to-edge separation) coated with 63.5 µm thick Kapton layer and aligned around a 3 mm tissue at 20 MHz.
Collapse
|
7
|
Simultaneous Power Feedback and Maximum Efficiency Point Tracking for Miniaturized RF Wireless Power Transfer Systems. SENSORS 2021; 21:s21062023. [PMID: 33809337 PMCID: PMC8000423 DOI: 10.3390/s21062023] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 03/05/2021] [Accepted: 03/09/2021] [Indexed: 11/17/2022]
Abstract
Near-field interfaces with miniaturized coil systems and low output power levels, such as applied in biomedical sensor systems, can suffer from severe efficiency degradation due to dynamic impedance mismatches, reducing battery life of the power transmitter unit and requiring to increase the level of electromagnetic emission. Moreover, the stability of weakly-coupled power transfer systems is generally limited by transient changes in coil alignment and load power consumption. Hence, a central research question in the domain of wireless power transfer is how to realize an adaptive impedance matching system under the constraints of a simultaneous power feedback to increase the system’s efficiency and stability, while maintaining circuit characteristics such as small size, low power consumption and fast reaction times. This paper presents a novel approach based on a two-stage control loop implemented in the primary-side reader unit, which uses a digital PI controller to maintain the rectifier output voltage for power feedback and an on-top perturb-and-observe controller configuring the setpoint of the voltage controller to maximize efficiency. The paper mathematically analyzes the AC and DC transfer characteristics of a resonant inductive link to design the reactive AC matching network, the digital voltage controller and ultimately the DC-domain impedance matching algorithm. It was found that static reactive L networks result in suitable efficiency levels for coils with sufficiently high quality factor even without adaptive tuning of operational frequency or reactive components. Furthermore, the regulated output voltage of the rectifier is a direct measure of the DC load impedance when using a regular DC/DC converter to supply the load circuits, so that this quantity can be tuned to maximize efficiency. A prototype implementation demonstrates the algorithms in a 40.68 MHz inductive link with load power levels from 10 to 100 mW and tuning time constants of 300 ms, while allowing for a simplified receiver with a footprint smaller than 200 mm2 and a self-consumption below 1 mW. Hence, the presented concepts enable adaptive impedance matching with favorable characteristics for low-energy sensor systems, i.e., minimized footprint, power level and reaction time.
Collapse
|
8
|
Erfani R, Marefat F, Mohseni P. A Dual-Output Single-Stage Regulating Rectifier With PWM and Dual-Mode PFM Control for Wireless Powering of Biomedical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; 14:1195-1206. [PMID: 33216720 DOI: 10.1109/tbcas.2020.3039690] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
This paper presents a reconfigurable, dual-output, regulating rectifier featuring pulse width modulation (PWM) and dual-mode pulse frequency modulation (PFM) control schemes for single-stage ac-to-dc conversion to provide two independently regulated supply voltages (each in 1.5-3 V) from an input ac voltage. The dual-mode PFM controllers feature event-driven regulation as well as frequency division. The former incorporates stable, fast, digital feedback loops to adaptively adjust the driving frequency of four power transistors, MP1∼4, based on the desired output power level to perform voltage regulation and deliver fast, transient, load currents. The latter sets the driving frequency of MP1∼4 to a user-defined fraction (1/1 ∼ 1/32) of the input frequency (1-10 MHz). The PWM controllers incorporate stable, analog, feedback loops to accurately adjust the conduction duration of MP1∼4 for voltage regulation and can be combined with PFM frequency division for an extended operation dynamic range. Fabricated in 0.18 μm 1P/6M CMOS, the regulating rectifier features power conversion efficiency (PCE) of >83.8% at 2 and 5 MHz, with the first output channel delivering ∼1 mW from VDD of 1.5 V and the second output channel delivering variable power from VDDH of 2.5 V to a load in the range of 0.1 to 1 kΩ. Peak PCE values of 90.75% (2 MHz, 100 Ω) and 90.7% (5 MHz, 200 Ω) are also measured. The regulating rectifier is suitable for the emerging modality of capacitive wireless power transfer to biomedical implants.
Collapse
|
9
|
Gougheri HS, Graybill P, Kiani M. A Dual-Output Reconfigurable Shared-Inductor Boost-Converter/Current-Mode Inductive Power Management ASIC With 750% Extended Output-Power Range, Adaptive Switching Control, and Voltage-Power Regulation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:1075-1086. [PMID: 31449030 PMCID: PMC6892643 DOI: 10.1109/tbcas.2019.2937253] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This paper describes a dual-output, reconfigurable integrated power management (IPM) ASIC for inductive power delivery. The proposed ASIC operates either as a current-mode (CM) rectifier or a boost converter by sharing the receiver (Rx) coil (LRx) to improve performance of inductive power transmission against the variations of Rx input power (PRx) and dual-output DC power (PL+ PHv). Conventional IPM structures either fail to generate regulated outputs (e.g., VL and VHv) when the required PL+ PHv exceeds PRx or suffer from low power-conversion efficiency (PCE) when PRx exceeds PL+ PHv due to voltage regulation and protection. To overcome these challenges, the proposed ASIC offers the unique capabilities of 1) generating multiple regulated outputs [Formula: see text] directly from LRx with single-stage conversion, 2) efficient CM operation with active rectification, enabled by adaptive switching control (ASC), 3) charging a large capacitor ( CS) with the purpose of operating as a shared-inductor boost converter (SBC), transferring energy from CS to CL and CHv, when , and 4) efficient voltage-power regulation (VPR). A proof-of-concept chip was fabricated in a 0.35-μm 2P4M standard CMOS process occupying 1.35-mm2 active area. In measurements, the proposed ASIC was able to successfully provide regulated [Formula: see text] and [Formula: see text] despite significant variations in PRx, PL, and PHv. Moreover, the chip extended the peak output power range by 750% and improved the PCE by 1.3 times and 8.1 times thanks to the ASC and VPR, respectively.
Collapse
|
10
|
An active metasurface for field-localizing wireless power transfer using dynamically reconfigurable cavities. Sci Rep 2019; 9:11735. [PMID: 31409834 PMCID: PMC6692501 DOI: 10.1038/s41598-019-48253-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Accepted: 07/26/2019] [Indexed: 11/26/2022] Open
Abstract
Wireless power transfer (WPT) provides a convenient method of delivering energy to multiple devices. With the increasing use of WPT, safety concerns inevitably create the need for a reliable control mechanism. Previous approaches in advanced WPT or metamaterial-enhanced WPT, however, have the limitation that neither the intensity nor the shape of the field-localizing area can be dynamically controlled. To address this limitation, we introduce the novel concept of a hotspot or power-focused region using field-localizing WPT. Using the proposed method, we provide experimental evidence demonstrating that the location, shape, and intensity of the hotspot can be manipulated as desired. The hotspot effectively enhances power delivery to the intended device while reducing leakage to unwanted areas. To dynamically reconfigure the hotspots, we propose an active metasurface with multi-functionality due to its frequency switching and tuning capability. The dynamic reconfiguring capability provides a wide range of versatile practical applications, overcoming the limitations associated with passive metamaterials. Because the location, shape, and intensity of hotspots can readily be controlled, the proposed method is not limited to WPT applications. It can also be used for a broad range of applications that require precise control of power delivery.
Collapse
|
11
|
Jia Y, Mirbozorgi SA, Zhang P, Inan OT, Li W, Ghovanloo M. A Dual-Band Wireless Power Transmission System for Evaluating mm-Sized Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:595-607. [PMID: 31071052 PMCID: PMC6728165 DOI: 10.1109/tbcas.2019.2915649] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Distributed neural interfaces made of many mm-sized implantable medical devices (IMDs) are poised to play a key role in future brain-computer interfaces because of less damage to the surrounding tissue. Evaluating them wirelessly at preclinical stage (e.g., in a rodent model), however, is a major challenge due to weak coupling and significant losses, resulting in limited power delivery to the IMD within a nominal experimental arena, like a homecage, without surpassing the specific absorption rate limit. To address this problem, we present a dual-band EnerCage system with two multi-coil inductive links, which first deliver power at 13.56 MHz from the EnerCage (46 × 24 × 20 cm3) to a headstage (18 × 18 × 15 mm3, 4.8 g) that is carried by the animal via a 4-coil inductive link. Then, a 60 MHz 3-coil inductive link from the headstage powers up the small IMD (2.5 × 2.5 × 1.5 mm3, 15 mg), which in this case is a free floating, wirelessly powered, implantable optical stimulator (FF-WIOS). The power transfer efficiency and power delivered to the load (PDL) from EnerCage to the headstage at 7 cm height were 14.9%-22.7% and 122 mW; and from headstage to FF-WIOS at 5 mm depth were 18% and 2.7 mW, respectively. Bidirectional data connectivity between EnerCage-headstage was established via bluetooth low energy. Between headstage and FF-WIOS, on-off keying and load-shift-keying were used for downlink and uplink data, respectively. Moreover, a closed-loop power controller stabilized PDL to both the headstage and the FF-WIOS against misalignments.
Collapse
|
12
|
Jia Y, Mirbozorgi SA, Lee B, Khan W, Madi F, Inan OT, Weber A, Li W, Ghovanloo M. A mm-Sized Free-Floating Wirelessly Powered Implantable Optical Stimulation Device. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:608-618. [PMID: 31135371 PMCID: PMC6707363 DOI: 10.1109/tbcas.2019.2918761] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
This paper presents a mm-sized, free-floating, wirelessly powered, implantable optical stimulation (FF-WIOS) device for untethered optogenetic neuromodulation. A resonator-based three-coil inductive link creates a homogeneous magnetic field that continuously delivers sufficient power (>2.7 mW) at an optimal carrier frequency of 60 MHz to the FF-WIOS in the near field without surpassing the specific absorption rate limit, regardless of the position of the FF-WIOS in a large brain area. Forward data telemetry carries stimulation parameters by on-off-keying the power carrier at a data rate of 50 kb/s to selectively activate a 4 × 4 μLED array. Load-shift-keying back telemetry controls the wireless power transmission by reporting the FF-WIOS received power level in a closed-loop power control mechanism. LEDs typically require high instantaneous power to emit sufficient light for optical stimulation. Thus, a switched-capacitor-based stimulation architecture is used as an energy storage buffer with one off-chip capacitor to receive charge directly from the inductive link and deliver it to the selected μLED at the onset of stimulation. The FF-WIOS system-on-a-chip prototype, fabricated in a 0.35-μm standard CMOS process, charges a 10-μF capacitor up to 5 V with 37% efficiency and passes instantaneous current spikes up to 10 mA in the selected μLED, creating a bright exponentially decaying flash with minimal wasted power. An in vivo experiment was conducted to verify the efficacy of the FF-WIOS by observing light-evoked local field potentials and immunostained tissue response from the primary visual cortex (V1) of two anesthetized rats.
Collapse
|
13
|
Schormans M, Valente V, Demosthenous A. Practical Inductive Link Design for Biomedical Wireless Power Transfer: A Tutorial. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2018; 12:1112-1130. [PMID: 30010596 DOI: 10.1109/tbcas.2018.2846020] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Wireless power transfer systems, particularly those based on inductive coupling, provide an increasingly attractive method to safely deliver power to biomedical implants. Although there exists a large body of literature describing the design of inductive links, it generally focuses on single aspects of the design process. There is a variety of approaches, some analytic, some numerical, each with benefits and drawbacks. As a result, undertaking a link design can be a difficult task, particularly for a newcomer to the subject. This tutorial paper reviews and collects the methods and equations that are required to design an inductive link for biomedical wireless power transfer, with a focus on practicality. It introduces and explains the published methods and principles relevant to all aspects of inductive link design, such that no specific prior knowledge of inductive link design is required. These methods are also combined into a software package (the Coupled Coil Configurator), to further simplify the design process. This software is demonstrated with a design example, to serve as a practical illustration.
Collapse
|
14
|
Ibrahim A, Meng M, Kiani M. A Comprehensive Comparative Study on Inductive and Ultrasonic Wireless Power Transmission to Biomedical Implants. IEEE SENSORS JOURNAL 2018; 18:3813-3826. [PMID: 30344453 PMCID: PMC6192045 DOI: 10.1109/jsen.2018.2812420] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
This paper presents a comprehensive comparison between inductive coupling and ultrasound for wireless power transmission (WPT) to biomedical implants. Several sets of inductive and ultrasonic links for different powering distances (d 12) and receiver dimensions have been optimized, and their key parameters, including power transmission efficiency (PTE) and power delivered to the load (PDL) within safety constraints, have been compared to find out which method is optimal for any given condition. Two design procedures have been presented for maximizing the PTE of inductive and ultrasonic links by finding the optimal geometry for the transmitter (Tx) and receiver (Rx) coils and ultrasonic transducers as well as the optimal operation frequency (fp ). Our simulation and measurement results showed that the ultrasonic link transcends the inductive link in PTE and somewhat in PDL for a small Rx of 1.1 mm3 (diameter of 1.2 mm), particularly when the Rx was deeply implanted inside the tissue (d 12 ≥ 10 mm). However, for a larger 20 mm3 Rx (diameter of 5 mm), the inductive link achieved higher PTE and PDL, particularly at shorter distances (d 12 < 30 mm). The optimal loading condition is shown to be quite different in inductive and ultrasonic links. Despite higher performance for small Rx and large d 12, the ultrasonic link is more sensitive to Rx misalignments and orientations. This led us to propose a new design procedure based on the worst-case misalignment scenario. The simulation results have been validated by measurements. The inductive and ultrasonic links, operating at 30 MHz and 1.1 MHz, achieved measured PTEs of 0.05% and 0.65% for the 1.1 mm3 Rx located 30 mm inside tissue and oil environments with optimal load resistances of 295 Ω and 3.8 kΩ, respectively.
Collapse
Affiliation(s)
- Ahmed Ibrahim
- Electrical Engineering Department at the Pennsylvania State University, University Park, PA 16802, USA
| | - Miao Meng
- Electrical Engineering Department at the Pennsylvania State University, University Park, PA 16802, USA
| | - Mehdi Kiani
- Electrical Engineering Department at the Pennsylvania State University, University Park, PA 16802, USA
| |
Collapse
|
15
|
Tanabe Y, Ho JS, Liu J, Liao SY, Zhen Z, Hsu S, Shuto C, Zhu ZY, Ma A, Vassos C, Chen P, Tse HF, Poon ASY. High-performance wireless powering for peripheral nerve neuromodulation systems. PLoS One 2017; 12:e0186698. [PMID: 29065141 PMCID: PMC5655495 DOI: 10.1371/journal.pone.0186698] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Accepted: 10/05/2017] [Indexed: 01/16/2023] Open
Abstract
Neuromodulation of peripheral nerves with bioelectronic devices is a promising approach for treating a wide range of disorders. Wireless powering could enable long-term operation of these devices, but achieving high performance for miniaturized and deeply placed devices remains a technological challenge. We report the miniaturized integration of a wireless powering system in soft neuromodulation device (15 mm length, 2.7 mm diameter) and demonstrate high performance (about 10%) during in vivo wireless stimulation of the vagus nerve in a porcine animal model. The increased performance is enabled by the generation of a focused and circularly polarized field that enhances efficiency and provides immunity to polarization misalignment. These performance characteristics establish the clinical potential of wireless powering for emerging therapies based on neuromodulation.
Collapse
Affiliation(s)
- Yuji Tanabe
- Department of Electrical Engineering, Stanford University, Stanford, California 94305, United States of America
| | - John S. Ho
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117583, Singapore
| | - Jiayin Liu
- Center for Innovation and Strategic Collaboration, St. Jude Medical, Inc., Orange County, California 92618, United States of America
| | - Song-Yan Liao
- Department of Medicine, University of Hong Kong, Hong Kong, China
| | - Zhe Zhen
- Department of Medicine, University of Hong Kong, Hong Kong, China
| | - Stephanie Hsu
- Department of Electrical Engineering, Stanford University, Stanford, California 94305, United States of America
| | - Chika Shuto
- Center for Innovation and Strategic Collaboration, St. Jude Medical, Inc., Orange County, California 92618, United States of America
| | - Zi-Yi Zhu
- Department of Medicine, University of Hong Kong, Hong Kong, China
| | - Andrew Ma
- Department of Electrical Engineering, Stanford University, Stanford, California 94305, United States of America
| | - Christopher Vassos
- Department of Electrical Engineering, Stanford University, Stanford, California 94305, United States of America
| | - Peter Chen
- Center for Innovation and Strategic Collaboration, St. Jude Medical, Inc., Orange County, California 92618, United States of America
| | - Hung Fat Tse
- Department of Medicine, University of Hong Kong, Hong Kong, China
- Hong Kong-Guangdong Joint Laboratory on Stem Cell and Regenerative Medicine, University of Hong Kong, Hong Kong, China
| | - Ada S. Y. Poon
- Department of Electrical Engineering, Stanford University, Stanford, California 94305, United States of America
- * E-mail:
| |
Collapse
|
16
|
Lee HM, Howell B, Grill WM, Ghovanloo M. Stimulation Efficiency With Decaying Exponential Waveforms in a Wirelessly Powered Switched-Capacitor Discharge Stimulation System. IEEE Trans Biomed Eng 2017; 65:1095-1106. [PMID: 28829301 DOI: 10.1109/tbme.2017.2741107] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
The purpose of this study was to test the feasibility of using a switched-capacitor discharge stimulation (SCDS) system for electrical stimulation, and, subsequently, determine the overall energy saved compared to a conventional stimulator. We have constructed a computational model by pairing an image-based volume conductor model of the cat head with cable models of corticospinal tract (CST) axons and quantified the theoretical stimulation efficiency of rectangular and decaying exponential waveforms, produced by conventional and SCDS systems, respectively. Subsequently, the model predictions were tested in vivo by activating axons in the posterior internal capsule and recording evoked electromyography (EMG) in the contralateral upper arm muscles. Compared to rectangular waveforms, decaying exponential waveforms with time constants >500 μs were predicted to require 2%-4% less stimulus energy to activate directly models of CST axons and 0.4%-2% less stimulus energy to evoke EMG activity in vivo. Using the calculated wireless input energy of the stimulation system and the measured stimulus energies required to evoke EMG activity, we predict that an SCDS implantable pulse generator (IPG) will require 40% less input energy than a conventional IPG to activate target neural elements. A wireless SCDS IPG that is more energy efficient than a conventional IPG will reduce the size of an implant, require that less wireless energy be transmitted through the skin, and extend the lifetime of the battery in the external power transmitter.
Collapse
|
17
|
Gong C, Liu D, Miao Z, Li M. A Magnetic-Balanced Inductive Link for the Simultaneous Uplink Data and Power Telemetry. SENSORS 2017; 17:s17081768. [PMID: 28767090 PMCID: PMC5580024 DOI: 10.3390/s17081768] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Revised: 07/30/2017] [Accepted: 07/30/2017] [Indexed: 11/16/2022]
Abstract
When using the conventional two-coil inductive link for the simultaneous wireless power and data transmissions in implantable biomedical sensor devices, the strong power carrier could overwhelm the uplink data signal and even saturate the external uplink receiver. To address this problem, we propose a new magnetic-balanced inductive link for our implantable glaucoma treatment device. In this inductive link, an extra coil is specially added for the uplink receiving. The strong power carrier interference is minimized to approach zero by balanced canceling of the magnetic field of the external power coil. The implant coil is shared by the wireless power harvesting and the uplink data transmitting. Two carriers (i.e., 2-MHz power carrier and 500-kHz uplink carrier) are used for the wireless power transmission and the uplink data transmission separately. In the experiments, the prototype of this link achieves as high as 65.72 dB improvement of the signal-to-interference ratio (SIR) compared with the conventional two-coil inductive link. Benefiting from the significant improvement of SIR, the implant transmitter costs only 0.2 mW of power carrying 50 kbps of binary phase shift keying data and gets a bit error rate of 1 × 10−7, even though the coupling coefficient is as low as 0.005. At the same time, 5 mW is delivered to the load with maximum power transfer efficiency of 58.8%. This magnetic-balanced inductive link is useful for small-sized biomedical sensor devices, which require transmitting data and power simultaneously under ultra-weak coupling.
Collapse
Affiliation(s)
- Chen Gong
- Institute of Application Specific Instruction-Set Processors, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China.
| | - Dake Liu
- Institute of Application Specific Instruction-Set Processors, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China.
| | - Zhidong Miao
- Institute of Application Specific Instruction-Set Processors, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China.
| | - Min Li
- Institute of Application Specific Instruction-Set Processors, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China.
| |
Collapse
|
18
|
Gong FX, Wei Z, Chi H, Yin B, Sun Y, Cong Y, Sun M. Position and Angular Misalignment Analysis for Implantable Wireless Power Transfer System Based on Magnetic Resonance. J Med Biol Eng 2017. [DOI: 10.1007/s40846-017-0277-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
19
|
Gong C, Liu D, Miao Z, Wang W, Li M. An NFC on Two-Coil WPT Link for Implantable Biomedical Sensors under Ultra-Weak Coupling. SENSORS 2017; 17:s17061358. [PMID: 28604610 PMCID: PMC5491991 DOI: 10.3390/s17061358] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2017] [Revised: 05/26/2017] [Accepted: 06/07/2017] [Indexed: 11/16/2022]
Abstract
The inductive link is widely used in implantable biomedical sensor systems to achieve near-field communication (NFC) and wireless power transfer (WPT). However, it is tough to achieve reliable NFC on an inductive WPT link when the coupling coefficient is ultra-low (0.01 typically), since the NFC signal (especially for the uplink from the in-body part to the out-body part) could be too weak to be detected. Traditional load shift keying (LSK) requires strong coupling to pass the load modulation information to the power source. Instead of using LSK, we propose a dual-carrier NFC scheme for the weak-coupled inductive link; using binary phase shift keying (BPSK) modulation, its downlink data are modulated on the power carrier (2 MHz), while its uplink data are modulated on another carrier (125 kHz). The two carriers are transferred through the same coil pair. To overcome the strong interference of the power carrier, dedicated circuits are introduced. In addition, to minimize the power transfer efficiency decrease caused by adding NFC, we optimize the inductive link circuit parameters and approach the receiver sensitivity limit. In the prototype experiments, even though the coupling coefficient is as low as 0.008, the in-body transmitter costs only 0.61 mW power carrying 10 kbps of data, and achieves a 1 × 10 - 7 bit error rate under the strong interference of WPT. This dual-carrier NFC scheme could be useful for small-sized implantable biomedical sensor applications.
Collapse
Affiliation(s)
- Chen Gong
- Institute of Application Specific Instruction-Set Processors, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China.
| | - Dake Liu
- Institute of Application Specific Instruction-Set Processors, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China.
| | - Zhidong Miao
- Institute of Application Specific Instruction-Set Processors, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China.
| | - Wei Wang
- Institute of Application Specific Instruction-Set Processors, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China.
| | - Min Li
- Institute of Application Specific Instruction-Set Processors, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China.
| |
Collapse
|
20
|
Danilov AA, Mindubaev EA, Selishchev SV. Methods for Compensation of Coil Misalignment in Systems for Inductive Transcutaneous Power Transfer to Implanted Medical Devices. BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA 2017. [DOI: 10.1007/s10527-017-9684-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
21
|
Jia Y, Mirbozorgi SA, Wang Z, Hsu CC, Madsen TE, Rainnie D, Ghovanloo M. Position and Orientation Insensitive Wireless Power Transmission for EnerCage-Homecage System. IEEE Trans Biomed Eng 2017; 64:2439-2449. [PMID: 28410095 DOI: 10.1109/tbme.2017.2691720] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
We have developed a new headstage architecture as part of a smart experimental arena, known as the EnerCage-HC2 system, which automatically delivers stimulation and collects behavioral data over extended periods with minimal small animal subject handling or personnel intervention in a standard rodent homecage. Equipped with a four-coil inductive link, the EnerCage-HC2 system wirelessly powers the receiver (Rx) headstage, irrespective of the subject's location or head orientation, eliminating the need for tethering or carrying bulky batteries. On the transmitter (Tx) side, a driver coil, five high-quality (Q) factor segmented resonators at different heights and orientations, and a closed-loop Tx power controller create a homogeneous electromagnetic (EM) field within the homecage 3-D space, and compensate for drops in power transfer efficiency (PTE) due to Rx misalignments. The headstage is equipped with four small slanted resonators, each covering a range of head orientations with respect to the Tx resonators, which direct the EM field toward the load coil at the bottom of the headstage. Moreover, data links based on Wi-Fi, UART, and Bluetooth low energy are utilized to enables remote communication and control of the Rx. The PTE varies within 23.6%-33.3% and 6.7%-10.1% at headstage heights of 8 and 20 cm, respectively, while continuously delivering >40 mW to the Rx electronics even at 90° rotation. As a proof of EnerCage-HC2 functionality in vivo, a previously documented on-demand electrical stimulation of the globus pallidus, eliciting consistent head rotation, is demonstrated in three freely behaving rats.
Collapse
|
22
|
Agarwal K, Jegadeesan R, Guo YX, Thakor NV. Wireless Power Transfer Strategies for Implantable Bioelectronics. IEEE Rev Biomed Eng 2017; 10:136-161. [PMID: 28328511 DOI: 10.1109/rbme.2017.2683520] [Citation(s) in RCA: 85] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Neural implants have emerged over the last decade as highly effective solutions for the treatment of dysfunctions and disorders of the nervous system. These implants establish a direct, often bidirectional, interface to the nervous system, both sensing neural signals and providing therapeutic treatments. As a result of the technological progress and successful clinical demonstrations, completely implantable solutions have become a reality and are now commercially available for the treatment of various functional disorders. Central to this development is the wireless power transfer (WPT) that has enabled implantable medical devices (IMDs) to function for extended durations in mobile subjects. In this review, we present the theory, link design, and challenges, along with their probable solutions for the traditional near-field resonant inductively coupled WPT, capacitively coupled short-ranged WPT, and more recently developed ultrasonic, mid-field, and far-field coupled WPT technologies for implantable applications. A comparison of various power transfer methods based on their power budgets and WPT range follows. Power requirements of specific implants like cochlear, retinal, cortical, and peripheral are also considered and currently available IMD solutions are discussed. Patient's safety concerns with respect to electrical, biological, physical, electromagnetic interference, and cyber security from an implanted neurotech device are also explored in this review. Finally, we discuss and anticipate future developments that will enhance the capabilities of current-day wirelessly powered implants and make them more efficient and integrable with other electronic components in IMDs.
Collapse
|
23
|
Javan-Khoskholgh A, Abukhalaf Z, Miller LS, Kiani M, Farajidavar A. An inductive narrow-pulse RFID telemetry system for gastric slow waves monitoring. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:4820-4823. [PMID: 28269349 DOI: 10.1109/embc.2016.7591806] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
We present a passive data telemetry system for real-time monitoring of gastric electrical activity of a living subject. The system is composed of three subsystems: an implantable unit (IU), a wearable unit (WU), and a stationary unit (SU). Data communication between the IU and WU is based on a radio-frequency identification (RFID) link operating at 13.56 MHz. Since wireless power transmission and reverse data telemetry system share the same inductive interface, a load shift keying (LSK)-based differential pulse position (DPP) coding data communication with only 6.25% duty cycle is developed to guarantee consistent wireless downlink power transmission and uplink high data transfer rate, simultaneously. The clock and data are encoded into one signal by an MSP430 microcontroller (MCU) at the IU side. This signal is sent to the WU through the inductive link, where decoded by an MSP432 MCU. Finally, the retrieved data at the WU are transmitted to the SU connected to a PC via a 2.4 GHz transceiver for real-time display and analysis. The results of the measurements on the implemented test bench, demonstrate IU-WU 125 kb/s and WU-SU 2 Mb/s data transmission rate with no observed mismatch, while the data stream was randomly generated, and matching between the transmitted data by the IU and received by the SU verified by a custom-made automated software.
Collapse
|
24
|
Ghanad MA, Green MM, Dehollain C. A 30 $\mu\text{W}$ Remotely Powered Local Temperature Monitoring Implantable System. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2017; 11:54-63. [PMID: 27514065 DOI: 10.1109/tbcas.2016.2574895] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
An implantable local temperature monitoring system for a laboratory mouse is presented. Magnetic coupling is used to remotely power the passive implant. The temperatures of two local points are monitored by thermistors. A low-power readout circuit is implemented by directly amplifying and resolving the sensor response in the time domain. A free-running oscillator operating at 868 MHz transmits the sensor data to the base station. The average power dissipation of the implant is decreased by time interleaving between the sensor readout and the data communication. The power transfer to the implant is also time interleaved with other operations to avoid interference with data communication. A voltage regulation loop for the implant based on controlling the duration of powering the base station power amplifier is also described. A prototype chip is implemented in 0.18 [Formula: see text] CMOS. The implant requires average RF power of 29.5 [Formula: see text] for operation and is capable of measuring two thermistors with accuracy of ±0.05 °C.
Collapse
|
25
|
Meng M, Kiani M. Design and Optimization of Ultrasonic Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2017; 11:98-107. [PMID: 27662684 DOI: 10.1109/tbcas.2016.2583783] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Ultrasound has been recently proposed as an alternative modality for efficient wireless power transmission (WPT) to biomedical implants with millimeter (mm) dimensions. This paper presents the theory and design methodology of ultrasonic WPT links that involve mm-sized receivers (Rx). For given load (RL) and powering distance (d), the optimal geometries of transmitter (Tx) and Rx ultrasonic transducers, including their diameter and thickness, as well as the optimal operation frequency (fc) are found through a recursive design procedure to maximize the power transmission efficiency (PTE). First, a range of realistic fcs is found based on the Rx thickness constrain. For a chosen fc within the range, the diameter and thickness of the Rx transducer are then swept together to maximize PTE. Then, the diameter and thickness of the Tx transducer are optimized to maximize PTE. Finally, this procedure is repeated for different fcs to find the optimal fc and its corresponding transducer geometries that maximize PTE. A design example of ultrasonic link has been presented and optimized for WPT to a 1 mm3 implant, including a disk-shaped piezoelectric transducer on a silicon die. In simulations, a PTE of 2.11% at fc of 1.8 MHz was achieved for RL of 2.5 [Formula: see text] at [Formula: see text]. In order to validate our simulations, an ultrasonic link was optimized for a 1 mm3 piezoelectric transducer mounted on a printed circuit board (PCB), which led to simulated and measured PTEs of 0.65% and 0.66% at fc of 1.1 MHz for RL of 2.5 [Formula: see text] at [Formula: see text], respectively.
Collapse
|
26
|
Frequency Splitting Analysis and Compensation Method for Inductive Wireless Powering of Implantable Biosensors. SENSORS 2016; 16:s16081229. [PMID: 27527174 PMCID: PMC5017394 DOI: 10.3390/s16081229] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Revised: 07/19/2016] [Accepted: 07/29/2016] [Indexed: 11/17/2022]
Abstract
Inductive powering for implanted medical devices, such as implantable biosensors, is a safe and effective technique that allows power to be delivered to implants wirelessly, avoiding the use of transcutaneous wires or implanted batteries. Wireless powering is very sensitive to a number of link parameters, including coil distance, alignment, shape, and load conditions. The optimum drive frequency of an inductive link varies depending on the coil spacing and load. This paper presents an optimum frequency tracking (OFT) method, in which an inductive power link is driven at a frequency that is maintained at an optimum value to ensure that the link is working at resonance, and the output voltage is maximised. The method is shown to provide significant improvements in maintained secondary voltage and system efficiency for a range of loads when the link is overcoupled. The OFT method does not require the use of variable capacitors or inductors. When tested at frequencies around a nominal frequency of 5 MHz, the OFT method provides up to a twofold efficiency improvement compared to a fixed frequency drive. The system can be readily interfaced with passive implants or implantable biosensors, and lends itself to interfacing with designs such as distributed implanted sensor networks, where each implant is operating at a different frequency.
Collapse
|
27
|
Kiani M, Ghovanloo M. A smart homecage system with 3D tracking for long-term behavioral experiments. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2014:2016-9. [PMID: 25570379 DOI: 10.1109/embc.2014.6944011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A wirelessly-powered homecage system, called the EnerCage-HC, that is equipped with multi-coil wireless power transfer, closed-loop power control, optical behavioral tracking, and a graphic user interface (GUI) is presented for long-term electrophysiology experiments. The EnerCage-HC system can wirelessly power a mobile unit attached to a small animal subject and also track its behavior in real-time as it is housed inside a standard homecage. The EnerCage-HC system is equipped with one central and four overlapping slanted wire-wound coils (WWCs) with optimal geometries to form 3-and 4-coil power transmission links while operating at 13.56 MHz. Utilizing multi-coil links increases the power transfer efficiency (PTE) compared to conventional 2-coil links and also reduces the number of power amplifiers (PAs) to only one, which significantly reduces the system complexity, cost, and dissipated heat. A Microsoft Kinect installed 90 cm above the homecage localizes the animal position and orientation with 1.6 cm accuracy. An in vivo experiment was conducted on a freely behaving rat by continuously delivering 24 mW to the mobile unit for > 7 hours inside a standard homecage.
Collapse
|
28
|
Lin YP, Tang KT. An Inductive Power and Data Telemetry Subsystem With Fast Transient Low Dropout Regulator for Biomedical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:435-444. [PMID: 26285218 DOI: 10.1109/tbcas.2015.2447526] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This paper presents a capacitorless low-dropout (LDO) regulator with fast transient response and data reverse telemetry circuit for fully implantable wireless transmission applications. We propose a novel hybrid feedback structure using high-frequency compensation technology to achieve a rapid transient response for the LDO regulator. To reduce the size of the implant and transmit neural recordings through the same coil without interfering with power transmission, the load-shift-key (LSK) modulation technique is adopted for back data telemetry. The proposed implantable chip, fabricated using commercial 0.18 μm complementary metal oxide semiconductor technology, yielded an output power of 15 mW. Under 1.15 V operation voltage, the maximum overshoot and undershoot voltages were less than 45 mV and 55 mV, respectively, for a 15 mA full-load current whose rising and falling time were less than 100 ns. The proposed LSK transceiver uses a digitized demodulator to improve bandwidth efficiency for low carrier frequency operation.
Collapse
|
29
|
Bocan KN, Sejdić E. Adaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review. SENSORS 2016; 16:s16030393. [PMID: 26999154 PMCID: PMC4813968 DOI: 10.3390/s16030393] [Citation(s) in RCA: 87] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Revised: 02/26/2016] [Accepted: 03/11/2016] [Indexed: 11/16/2022]
Abstract
Wireless energy transfer is a broad research area that has recently become applicable to implantable medical devices. Wireless powering of and communication with implanted devices is possible through wireless transcutaneous energy transfer. However, designing wireless transcutaneous systems is complicated due to the variability of the environment. The focus of this review is on strategies to sense and adapt to environmental variations in wireless transcutaneous systems. Adaptive systems provide the ability to maintain performance in the face of both unpredictability (variation from expected parameters) and variability (changes over time). Current strategies in adaptive (or tunable) systems include sensing relevant metrics to evaluate the function of the system in its environment and adjusting control parameters according to sensed values through the use of tunable components. Some challenges of applying adaptive designs to implantable devices are challenges common to all implantable devices, including size and power reduction on the implant, efficiency of power transfer and safety related to energy absorption in tissue. Challenges specifically associated with adaptation include choosing relevant and accessible parameters to sense and adjust, minimizing the tuning time and complexity of control, utilizing feedback from the implanted device and coordinating adaptation at the transmitter and receiver.
Collapse
Affiliation(s)
- Kara N Bocan
- Department of Electrical and Computer Engineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.
| | - Ervin Sejdić
- Department of Electrical and Computer Engineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.
| |
Collapse
|
30
|
Lee B, Kiani M, Ghovanloo M. A Triple-Loop Inductive Power Transmission System for Biomedical Applications. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:138-48. [PMID: 25667358 DOI: 10.1109/tbcas.2014.2376965] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
A triple-loop wireless power transmission (WPT) system equipped with closed-loop global power control, adaptive transmitter (Tx) resonance compensation (TRC), and automatic receiver (Rx) resonance tuning (ART) is presented. This system not only opposes coupling and load variations but also compensates for changes in the environment surrounding the inductive link to enhance power transfer efficiency (PTE) in applications such as implantable medical devices (IMDs). The Tx was built around a commercial off-the-shelf (COTS) radio-frequency identification (RFID) reader, operating at 13.56 MHz. A local Tx loop finds the optimal capacitance in parallel with the Tx coil by adjusting a varactor. A global power control loop maintains the received power at a desired level in the presence of changes in coupling distance, coil misalignments, and loading. Moreover, a local Rx loop is implemented inside a power management integrated circuit (PMIC) to avoid PTE degradation due to the Rx coil surrounding environment and process variations. The PMIC was fabricated in a 0.35- μm 4M2P standard CMOS process with 2.54 mm(2) active area. Measurement results show that the proposed triple-loop system improves the overall PTE by up to 10.5% and 4.7% compared to a similar open- and single closed-loop system, respectively, at nominal coil distance of 2 cm. The added TRC and ART loops contribute 2.3% and 1.4% to the overall PTE of 13.5%, respectively. This is the first WPT system to include three loops to dynamically compensate for environment and circuit variations and improve the overall power efficiency all the way from the driver output in Tx to the load in Rx.
Collapse
|
31
|
Li X, Meng X, Tsui CY, Ki WH. Reconfigurable Resonant Regulating Rectifier With Primary Equalization for Extended Coupling- and Loading-Range in Bio-Implant Wireless Power Transfer. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2015; 9:875-884. [PMID: 26742141 DOI: 10.1109/tbcas.2015.2503418] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Wireless power transfer using reconfigurable resonant regulating (R(3)) rectification suffers from limited range in accommodating varying coupling and loading conditions. A primary-assisted regulation principle is proposed to mitigate these limitations, of which the amplitude of the rectifier input voltage on the secondary side is regulated by accordingly adjusting the voltage amplitude Veq on the primary side. A novel current-sensing method and calibration scheme track Veq on the primary side. A ramp generator simultaneously provides three clock signals for different modules. Both the primary equalizer and the R(3) rectifier are implemented as custom integrated circuits fabricated in a 0.35 μm CMOS process, with the global control implemented in FPGA. Measurements show that with the primary equalizer, the workable coupling and loading ranges are extended by 250% at 120 mW load and 300% at 1.2 cm coil distance compared to the same system without the primary equalizer. A maximum rectifier efficiency of 92.5% and a total system efficiency of 62.4% are demonstrated.
Collapse
|
32
|
Lee B, Kiani M, Ghovanloo M. A Smart Wirelessly Powered Homecage for Long-Term High-Throughput Behavioral Experiments. IEEE SENSORS JOURNAL 2015; 15:4905-4916. [PMID: 26257586 PMCID: PMC4527654 DOI: 10.1109/jsen.2015.2430859] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
A wirelessly powered homecage system, called the EnerCage-HC, that is equipped with multicoil wireless power transfer, closed-loop power control, optical behavioral tracking, and a graphic user interface is presented for longitudinal electrophysiology and behavioral neuroscience experiments. The EnerCage-HC system can wirelessly power a mobile unit attached to a small animal subject and also track its behavior in real-time as it is housed inside a standard homecage. The EnerCage-HC system is equipped with one central and four overlapping slanted wire-wound coils with optimal geometries to form three- and four-coil power transmission links while operating at 13.56 MHz. Utilizing multicoil links increases the power transfer efficiency (PTE) compared with conventional two-coil links and also reduces the number of power amplifiers to only one, which significantly reduces the system complexity, cost, and heat dissipation. A Microsoft Kinect installed 90 cm above the homecage localizes the animal position and orientation with 1.6-cm accuracy. Moreover, a power management ASIC, including a high efficiency active rectifier and automatic coil resonance tuning, was fabricated in a 0.35-μm 4M2P standard CMOS process for the mobile unit. The EnerCage-HC achieves a max/min PTE of 36.3%/16.1% at the nominal height of 7 cm. In vivo experiments were conducted on freely behaving rats by continuously delivering 24 mW to the mobile unit for >7 h inside a standard homecage.
Collapse
Affiliation(s)
- Byunghun Lee
- GT-Bionics Laboratory, School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30308 USA
| | - Mehdi Kiani
- Electrical Engineering Department, Pennsylvania State University, University Park, PA 16802 USA
| | - Maysam Ghovanloo
- GT-Bionics Laboratory, School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30308 USA
| |
Collapse
|
33
|
Fattah N, Laha S, Sokolov D, Chester G, Degenaar P. Wireless data and power transfer of an optogenetic implantable visual cortex stimulator. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2015:8006-9. [PMID: 26738150 DOI: 10.1109/embc.2015.7320250] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In this paper, the wireless data and power transfer for a novel optogenetic visual cortex implant system was demonstrated by using pork tissue mimic in-vitro at the ISM 2.4 GHz and 13.5 MHz frequency band respectively. The observed data rate was 120 kbps with no loss in data for up to a thickness of 35 mm in both water & pork. To increase the power level of the implant a Class E power amplifier is separately designed and simulated for the transmitter end and has an output power of around 223 mW with an efficiency of 81.83%. The transferred power at the receiver was measured to be 66.80 mW for the pork tissue medium considering a distance of 5 mm between the transmitter and the receiver coils, with a coupling coefficient of ~0.8. This serves the power requirement of the visual cortex implant.
Collapse
|
34
|
Software-Based Wireless Power Transfer Platform for Various Power Control Experiments. ENERGIES 2015. [DOI: 10.3390/en8087677] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
35
|
Kilinc EG, Ghanad MA, Maloberti F, Dehollain C. A remotely powered implantable biomedical system with location detector. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2015; 9:113-123. [PMID: 24988596 DOI: 10.1109/tbcas.2014.2321524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
An universal remote powering and communication system is presented for the implantable medical devices. The system be interfaced with different sensors or actuators. A mobile external unit controls the operation of the implantable chip and reads the sensor's data. A locator system is proposed to align the mobile unit with the implant unit for the efficient magnetic power transfer. The location of the implant is detected with 6 mm resolution from the rectified voltage level at the implanted side. The rectified voltage level is fedback to the mobile unit to adjust the magnetic field strength and maximize the efficiency of the remote powering system. The sensor's data are transmitted by using a free running oscillator modulated with on-off key scheme. To tolerate large data carrier drifts, a custom designed receiver is implemented for the mobile unit. The circuits have been fabricated in 0.18 um CMOS technology. The remote powering link is optimized to deliver power at 13.56 MHz. On chip voltage regulator creates 1.8 V from a 0.9 V reference voltage to supply the sensor/actuator blocks. The implantable chip dissipates 595 μW and requires 1.48 V for start up.
Collapse
|
36
|
Hannan MA, Hussein HA, Mutashar S, Samad SA, Hussain A. Automatic frequency controller for power amplifiers used in bio-implanted applications: issues and challenges. SENSORS 2014; 14:23843-70. [PMID: 25615728 PMCID: PMC4299090 DOI: 10.3390/s141223843] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2014] [Revised: 11/06/2014] [Accepted: 11/24/2014] [Indexed: 11/16/2022]
Abstract
With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil's mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning the progress of implanted device research in the future. This review will hopefully lead to increasing efforts towards the development of low powered, highly efficient, high data rate and reliable automatic frequency controllers for implanted devices.
Collapse
Affiliation(s)
- Mahammad A Hannan
- Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia.
| | - Hussein A Hussein
- Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia.
| | - Saad Mutashar
- Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia.
| | - Salina A Samad
- Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia.
| | - Aini Hussain
- Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia.
| |
Collapse
|
37
|
McMenamin P, Kiani M, Manns JR, Ghovanloo M. EnerCage: a smart experimental arena with scalable architecture for behavioral experiments. IEEE Trans Biomed Eng 2013; 61:139-48. [PMID: 23955695 DOI: 10.1109/tbme.2013.2278180] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Wireless power, when coupled with miniaturized implantable electronics, has the potential to provide a solution to several challenges facing neuroscientists during basic and preclinical studies with freely behaving animals. The EnerCage system is one such solution as it allows for uninterrupted electrophysiology experiments over extended periods of time and vast experimental arenas, while eliminating the need for bulky battery payloads or tethering. It has a scalable array of overlapping planar spiral coils (PSCs) and three-axis magnetic sensors for focused wireless power transmission to devices on freely moving subjects. In this paper, we present the first fully functional EnerCage system, in which the number of PSC drivers and magnetic sensors was reduced to one-third of the number used in our previous design via multicoil coupling. The power transfer efficiency (PTE) has been improved to 5.6% at a 120 mm coupling distance and a 48.5 mm lateral misalignment (worst case) between the transmitter (Tx) array and receiver (Rx) coils. The new EnerCage system is equipped with an Ethernet backbone, further supporting its modular/scalable architecture, which, in turn, allows experimental arenas with arbitrary shapes and dimensions. A set of experiments on a freely behaving rat were conducted by continuously delivering 20 mW to the electronics in the animal headstage for more than one hour in a powered 3538 cm(2) experimental area.
Collapse
|
38
|
Chiu HW, Lu CC, Chuang JM, Lin WT, Lin CW, Kao MC, Lin ML. A dual-mode highly efficient class-E stimulator controlled by a low-Q class-E power amplifier through duty cycle. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2013; 7:243-255. [PMID: 23853324 DOI: 10.1109/tbcas.2012.2205245] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This paper presents the design flow of two high-efficiency class-E amplifiers for the implantable electrical stimulation system. The implantable stimulator is a high-Q class-E driver that delivers a sine-wave pulsed radiofrequency (PRF) stimulation, which was verified to have a superior efficacy in pain relief to a square wave. The proposed duty-cycle-controlled class-E PRF driver designed with a high-Q factor has two operational modes that are able to achieve 100% DC-AC conversion, and involves only one switched series inductor and an unchanged parallel capacitor. The measured output amplitude under low-voltage (LV) mode using a 22% duty cycle was 0.98 V with 91% efficiency, and under high-voltage (HV) mode using a 47% duty cycle was 2.95 V with 92% efficiency. These modes were inductively controlled by a duty-cycle detector, which can detect the duty-cycle modulated signal generated from the external complementary low-Q class-E power amplifier (PA). The design methodology of the low-Q inductive interface for a non-50% duty cycle is presented. The experimental results exhibits that the 1.5-V PA that consumes DC power of 14.21 mW was able to deliver a 2.9-V sine wave to a 500 Ω load. The optimal 60% drain efficiency of the system from the PA to the load was obtained at a 10-mm coupling distance.
Collapse
Affiliation(s)
- Hung-Wei Chiu
- Department of Electronic Engineering and Graduate Institute of Computer and Communication Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
| | | | | | | | | | | | | |
Collapse
|
39
|
Jow UM, Ghovanloo M. Geometrical Design of a Scalable Overlapping Planar Spiral Coil Array to Generate a Homogeneous Magnetic Field. IEEE TRANSACTIONS ON MAGNETICS 2012; 49:2933-2945. [PMID: 24782576 PMCID: PMC4000743 DOI: 10.1109/tmag.2012.2235181] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
We present a design methodology for an overlapping hexagonal planar spiral coil (hex-PSC) array, optimized for creation of a homogenous magnetic field for wireless power transmission to randomly moving objects. The modular hex-PSC array has been implemented in the form of three parallel conductive layers, for which an iterative optimization procedure defines the PSC geometries. Since the overlapping hex-PSCs in different layers have different characteristics, the worst case coil-coupling condition should be designed to provide the maximum power transfer efficiency (PTE) in order to minimize the spatial received power fluctuations. In the worst case, the transmitter (Tx) hex-PSC is overlapped by six PSCs and surrounded by six other adjacent PSCs. Using a receiver (Rx) coil, 20 mm in radius, at the coupling distance of 78 mm and maximum lateral misalignment of 49.1 mm (1/√3 of the PSC radius) we can receive power at a PTE of 19.6% from the worst case PSC. Furthermore, we have studied the effects of Rx coil tilting and concluded that the PTE degrades significantly when θ > 60°. Solutions are: 1) activating two adjacent overlapping hex-PSCs simultaneously with out-of-phase excitations to create horizontal magnetic flux and 2) inclusion of a small energy storage element in the Rx module to maintain power in the worst case scenarios. In order to verify the proposed design methodology, we have developed the EnerCage system, which aims to power up biological instruments attached to or implanted in freely behaving small animal subjects' bodies in long-term electrophysiology experiments within large experimental arenas.
Collapse
Affiliation(s)
- Uei-Ming Jow
- GT-Bionics Laboratory, School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30308 USA
| | - Maysam Ghovanloo
- GT-Bionics Laboratory, School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30308 USA
| |
Collapse
|
40
|
Zhang F, Aghagolzadeh M, Oweiss K. A Fully Implantable, Programmable and Multimodal Neuroprocessor for Wireless, Cortically Controlled Brain-Machine Interface Applications. JOURNAL OF SIGNAL PROCESSING SYSTEMS 2012; 69:351-361. [PMID: 23050029 PMCID: PMC3462457 DOI: 10.1007/s11265-012-0670-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Reliability, scalability and clinical viability are of utmost importance in the design of wireless Brain Machine Interface systems (BMIs). This paper reports on the design and implementation of a neuroprocessor for conditioning raw extracellular neural signals recorded through microelectrode arrays chronically implanted in the brain of awake behaving rats. The neuroprocessor design exploits a sparse representation of the neural signals to combat the limited wireless telemetry bandwidth. We demonstrate a multimodal processing capability (monitoring, compression, and spike sorting) inherent in the neuroprocessor to support a wide range of scenarios in real experimental conditions. A wireless transmission link with rate-dependent compression strategy is shown to preserve information fidelity in the neural data. At 32 channels, the neuroprocessor has been fully implemented on a 5mm×5mm nano-FPGA, and the prototyping resulted in 5.19 mW power consumption, bringing its performance within the power-size constraints for clinical use. The optimal design for compression and sorting performance was evaluated for multiple sampling frequencies, wavelet basis choice and power consumption.
Collapse
Affiliation(s)
- Fei Zhang
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824 USA (, )
| | - Mehdi Aghagolzadeh
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824 USA (, )
| | - Karim Oweiss
- Department of Electrical and Computer Engineering and Neuroscience Program, Michigan State University, East Lansing, MI 48824 USA ()
| |
Collapse
|
41
|
Kiani M, Ghovanloo M. A Figure-of-Merit for Designing High-Performance Inductive Power Transmission Links. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS (1982) 2012; 60:5292-5305. [PMID: 25382898 PMCID: PMC4223690 DOI: 10.1109/tie.2012.2227914] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Power transfer efficiency (PTE) and power delivered to the load (PDL) are two key inductive link design parameters that relate to the power source and driver specs, power loss, transmission range, robustness against misalignment, variations in loading, and interference with other devices. Designers need to strike a delicate balance between these two because designing the link to achieve high PTE will degrade the PDL and vice versa. We are proposing a new figure-of-merit (FoM), which can help designers to find out whether a two-, three-, or four-coil link is appropriate for their particular application and guide them through an iterative design procedure to reach optimal coil geometries based on how they weigh the PTE versus PDL for that application. Three design examples at three different power levels have been presented based on the proposed FoM for implantable microelectronic devices, handheld mobile devices, and electric vehicles. The new FoM suggests that the two-coil links are suitable when the coils are strongly coupled, and a large PDL is needed. Three-coil links are the best when the coils are loosely coupled, the coupling distance varies considerably, and large PDL is necessary. Finally, four-coil links are optimal when the PTE is paramount, the coils are loosely coupled, and their relative distance and alignment are stable. Measurement results support the accuracy of the theoretical design procedure and conclusions.
Collapse
|
42
|
Jow UM, Kiani M, Huo X, Ghovanloo M. Towards a smart experimental arena for long-term electrophysiology experiments. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2012; 6:414-23. [PMID: 23853228 PMCID: PMC3721429 DOI: 10.1109/tbcas.2012.2211872] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Wireless power and data transmission have created promising prospects in biomedical research by enabling perpetual data acquisition and stimulation systems. We present a work in progress towards such a system, called the EnerCage, equipped with scalable arrays of overlapping planar spiral coils (PSC) and 3-axis magnetic sensors for focused wireless power transmission to randomly moving targets, such as small freely behaving animal subjects. The EnerCage system includes a stationary unit for 3D non-line-of-sight localization and inductive power transmission through a geometrically optimized PSC array. The localization algorithm compares the magnetic sensor outputs with a threshold to activate a PSC. All PSCs are optimized based on the worst-case misalignment, considering parasitics from the overlapping and adjacent PSCs. EnerCage also has a mobile unit attached to or implanted in the subject's body, which includes a permanent magnetic tracer for localization and back telemetry circuit for efficient closed-loop inductive power regulation. The EnerCage system is designed to enable long-term electrophysiology experiments on freely behaving small animal subjects in large experimental arenas without requiring them to carry bulky batteries. A prototype of the EnerCage system with five PSCs and five magnetic sensors achieved power transfer efficiency (PTE) of 19.6% at the worst-case horizontal misalignment of 49.1 mm (√1/3 of the PSC radius) and coupling distance of 78 mm with a mobile unit coil, 20 mm in radius. The closed-loop power management mechanism maintains the mobile unit received power at 20 mW despite misalignments, tilting, and distance variations up to a maximum operating height of 120 mm (PTE = 5%).
Collapse
|
43
|
Zhang F, Aghagolzadeh M, Oweiss K. A programmable and implantable microsystem for multimodal processing of ensemble neural recordings. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:3035-8. [PMID: 22254979 DOI: 10.1109/iembs.2011.6090830] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Conditioning raw neural signals recorded through microelectrode arrays implanted in the brain is an important first step before information extraction can take place. This paper reports on the design and implementation of a programmable and fully implantable microsystem that fulfills this purpose. The system design builds on our earlier work that relies on a sparse representation of the neural signals to combat the limited telemetry bandwidth when wireless communication with the external world is sought. The system has a multimodal processing capability to support a wide range of scenarios in real experimental conditions. A transmission link with rate-dependent compression and spike sorting strategy is shown to preserve information fidelity. At 32 channels sampled at 25 kHz, the power consumption of the system is 5.19 mW and has been implemented on a 5 mm × 5 mm nano-FPGA, bringing its performance within the implantable power-size constraints for clinical applications.
Collapse
Affiliation(s)
- Fei Zhang
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA.
| | | | | |
Collapse
|
44
|
Ghovanloo M. An overview of the recent wideband transcutaneous wireless communication techniques. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:5864-7. [PMID: 22255673 DOI: 10.1109/iembs.2011.6091450] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Neuroprosthetic devices such as cochlear and retinal implants need to deliver a large volume of data from external sensors into the body, while invasive brain-computer interfaces need to deliver sizeable amounts of data from the central nervous system to target devices outside of the body. Nonetheless, the skin should remain intact. This paper reviews some of the latest techniques to establish wideband wireless communication links across the skin.
Collapse
Affiliation(s)
- Maysam Ghovanloo
- GT-Bionics lab, School of Electrical and Computer Engineering at the Georgia Institute of Technology, Atlanta, GA 30308, USA.
| |
Collapse
|
45
|
Kiani M, Kwon KY, Zhang F, Oweiss K, Ghovanloo M. Evaluation of a closed loop inductive power transmission system on an awake behaving animal subject. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:7658-61. [PMID: 22256112 DOI: 10.1109/iembs.2011.6091887] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This paper presents in vivo experimental results for a closed loop wireless power transmission system to implantable devices on an awake behaving animal subject. In this system, wireless power transmission takes place across an inductive link, controlled by a commercial off-the-shelf (COTS) radio frequency identification (RFID) transceiver (TRF7960) operating at 13.56 MHz. Induced voltage on the implantable secondary coil is rectified, digitized by a 10-bit analog to digital converter, and transmitted back to the primary via back telemetry. Transmitter (Tx) and receiver (Rx) circuitry were mounted on the back of an adult rat with a nominal distance of ~7 mm between their coils. Our experiments showed that the closed loop system was able to maintain the Rx supply voltage at the designated 3.8 V despite changes in the coils' relative distance and alignment due to animal movements. The Tx power consumption changed between 410 ~ 560 mW in order to deliver 27 mW to the receiver. The open loop system, on the other hand, showed undesired changes in the Rx supply voltage while the Tx power consumption was constant at 660 mW.
Collapse
Affiliation(s)
- Mehdi Kiani
- GT-Bionics Lab, School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | | | | | | | | |
Collapse
|
46
|
Kiani M, Jow UM, Ghovanloo M. Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2011; 99:1. [PMID: 21922034 PMCID: PMC3171453 DOI: 10.1109/tbcas.2011.2158431] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Inductive power transmission is widely used to energize implantable microelectronic devices (IMDs), recharge batteries, and energy harvesters. Power transfer efficiency (PTE) and power delivered to the load (PDL) are two key parameters in wireless links, which affect the energy source specifications, heat dissipation, power transmission range, and interference with other devices. To improve the PTE, a 4-coil inductive link has been recently proposed. Through a comprehensive circuit based analysis that can guide a design and optimization scheme, we have shown that despite achieving high PTE at larger coil separations, the 4-coil inductive links fail to achieve a high PDL. Instead, we have proposed a 3-coil inductive power transfer link with comparable PTE over its 4-coil counterpart at large coupling distances, which can also achieve high PDL. We have also devised an iterative design methodology that provides the optimal coil geometries in a 3-coil inductive power transfer link. Design examples of 2-, 3-, and 4-coil inductive links have been presented, and optimized for 13.56 MHz carrier frequency and 12 cm coupling distance, showing PTEs of 15%, 37%, and 35%, respectively. At this distance, the PDL of the proposed 3-coil inductive link is 1.5 and 59 times higher than its equivalent 2- and 4-coil links, respectively. For short coupling distances, however, 2-coil links remain the optimal choice when a high PDL is required, while 4-coil links are preferred when the driver has large output resistance or small power is needed. These results have been verified through simulations and measurements.
Collapse
Affiliation(s)
| | | | - Maysam Ghovanloo
- Corresponding author: (phone: 404-385-7048; fax: 404-894-4701, )
| |
Collapse
|
47
|
Lee HM, Ghovanloo M. An Integrated Power-Efficient Active Rectifier With Offset-Controlled High Speed Comparators for Inductively Powered Applications. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS. I, REGULAR PAPERS : A PUBLICATION OF THE IEEE CIRCUITS AND SYSTEMS SOCIETY 2011; 58:1749-1760. [PMID: 22174666 PMCID: PMC3235652 DOI: 10.1109/tcsi.2010.2103172] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We present an active full-wave rectifier with offset-controlled high speed comparators in standard CMOS that provides high power conversion efficiency (PCE) in high frequency (HF) range for inductively powered devices. This rectifier provides much lower dropout voltage and far better PCE compared to the passive on-chip or off-chip rectifiers. The built-in offset-control functions in the comparators compensate for both turn-on and turn-off delays in the main rectifying switches, thus maximizing the forward current delivered to the load and minimizing the back current to improve the PCE. We have fabricated this active rectifier in a 0.5-μm 3M2P standard CMOS process, occupying 0.18 mm(2) of chip area. With 3.8 V peak ac input at 13.56 MHz, the rectifier provides 3.12 V dc output to a 500 Ω load, resulting in the PCE of 80.2%, which is the highest measured at this frequency. In addition, overvoltage protection (OVP) as safety measure and built-in back telemetry capabilities have been incorporated in our design using detuning and load shift keying (LSK) techniques, respectively, and tested.
Collapse
|
48
|
Lee SB, Lee HM, Kiani M, Jow UM, Ghovanloo M. An Inductively Powered Scalable 32-Channel Wireless Neural Recording System-on-a-Chip for Neuroscience Applications. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2010; 4:360-71. [PMID: 23850753 PMCID: PMC4104168 DOI: 10.1109/tbcas.2010.2078814] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We present an inductively powered 32-channel wireless integrated neural recording (WINeR) system-on-a-chip (SoC) to be ultimately used for one or more small freely behaving animals. The inductive powering is intended to relieve the animals from carrying bulky batteries used in other wireless systems, and enables long recording sessions. The WINeR system uses time-division multiplexing along with a novel power scheduling method that reduces the current in unused low-noise amplifiers (LNAs) to cut the total SoC power consumption. In addition, an on-chip high-efficiency active rectifier with optimized coils help improve the overall system power efficiency, which is controlled in a closed loop to supply stable power to the WINeR regardless of the coil displacements. The WINeR SoC has been implemented in a 0.5-μ m standard complementary metal-oxide semiconductor process, measuring 4.9×3.3 mm(2) and consuming 5.85 mW at ±1.5 V when 12 out of 32 LNAs are active at any time by power scheduling. Measured input-referred noise for the entire system, including the receiver located at 1.2 m, is 4.95 μVrms in the 1 Hz~10 kHz range when the system is inductively powered with 7-cm separation between aligned coils.
Collapse
|