1
|
Gaulton TG, Xin Y, Victor M, Nova A, Cereda M. Imaging the pulmonary vasculature in acute respiratory distress syndrome. Nitric Oxide 2024; 147:6-12. [PMID: 38588918 DOI: 10.1016/j.niox.2024.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/21/2024] [Accepted: 04/03/2024] [Indexed: 04/10/2024]
Abstract
Acute respiratory distress syndrome (ARDS) is characterized by a redistribution of regional lung perfusion that impairs gas exchange. While speculative, experimental evidence suggests that perfusion redistribution may contribute to regional inflammation and modify disease progression. Unfortunately, tools to visualize and quantify lung perfusion in patients with ARDS are lacking. This review explores recent advances in perfusion imaging techniques that aim to understand the pulmonary circulation in ARDS. Dynamic contrast-enhanced computed tomography captures first-pass kinetics of intravenously injected dye during continuous scan acquisitions. Different contrast characteristics and kinetic modeling have improved its topographic measurement of pulmonary perfusion with high spatial and temporal resolution. Dual-energy computed tomography can map the pulmonary blood volume of the whole lung with limited radiation exposure, enabling its application in clinical research. Electrical impedance tomography can obtain serial topographic assessments of perfusion at the bedside in response to treatments such as inhaled nitric oxide and prone position. Ongoing technological improvements and emerging techniques will enhance lung perfusion imaging and aid its incorporation into the care of patients with ARDS.
Collapse
Affiliation(s)
- Timothy G Gaulton
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA.
| | - Yi Xin
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA
| | - Marcus Victor
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA; Electronics Engineering Division, Aeronautics Institute of Technology, Sao Paulo, Brazil
| | - Alice Nova
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA
| | - Maurizio Cereda
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
2
|
Rosén J, Frykholm P, Jonsson Fagerlund M, Pellegrini M, Campoccia Jalde F, von Oelreich E, Fors D. Lung impedance changes during awake prone positioning in COVID-19. A non-randomized cross-over study. PLoS One 2024; 19:e0299199. [PMID: 38381730 PMCID: PMC10880988 DOI: 10.1371/journal.pone.0299199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 02/01/2024] [Indexed: 02/23/2024] Open
Abstract
BACKGROUND The effects of awake prone positioning (APP) on respiratory mechanics in patients with COVID-19 are not well characterized. The aim of this study was to investigate changes of global and regional lung volumes during APP compared with the supine position using electrical lung impedance tomography (EIT) in patients with hypoxemic respiratory failure due to COVID-19. MATERIALS AND METHODS This exploratory non-randomized cross-over study was conducted at two university hospitals in Sweden between January and May 2021. Patients admitted to the intensive care unit with confirmed COVID-19, an arterial cannula in place, a PaO2/FiO2 ratio <26.6 kPa (<200 mmHg) and high-flow nasal oxygen or non-invasive ventilation were eligible for inclusion. EIT-data were recorded at supine baseline, at 30 and 60 minutes after APP-initiation, and 30 minutes after supine repositioning. The primary outcomes were changes in global and regional tidal impedance variation (TIV), center of ventilation (CoV), global and regional delta end-expiratory lung-impedance (dEELI) and global inhomogeneity (GI) index at the end of APP compared with supine baseline. Data were reported as median (IQR). RESULTS All patients (n = 10) were male and age was 64 (47-73) years. There were no changes in global or regional TIV, CoV or GI-index during the intervention. dEELI increased from supine reference value 0 to 1.51 (0.32-3.62) 60 minutes after APP (median difference 1.51 (95% CI 0.19-5.16), p = 0.04) and returned to near baseline values after supine repositioning. Seven patients (70%) showed an increase >0.20 in dEELI during APP. The other EIT-variables did not change during APP compared with baseline. CONCLUSION Awake prone positioning was associated with a transient lung recruiting effect without changes in ventilation distribution measured with EIT in patients with hypoxemic respiratory failure due to COVID-19.
Collapse
Affiliation(s)
- Jacob Rosén
- Department of Surgical Sciences, Anaesthesiology and Intensive Care Medicine, Uppsala University, Uppsala, Sweden
| | - Peter Frykholm
- Department of Surgical Sciences, Anaesthesiology and Intensive Care Medicine, Uppsala University, Uppsala, Sweden
| | - Malin Jonsson Fagerlund
- Perioperative Medicine and Intensive Care, Karolinska University Hospital, Solna, Sweden
- Section of Anesthesiology and Intensive Care Medicine, Department of Physiology and Pharmacology, Karolinska Institutet, Solna, Sweden
| | - Mariangela Pellegrini
- Department of Surgical Sciences, Anaesthesiology and Intensive Care Medicine, Uppsala University, Uppsala, Sweden
| | - Francesca Campoccia Jalde
- Perioperative Medicine and Intensive Care, Karolinska University Hospital, Solna, Sweden
- Section of Thoracic Anesthesiology and Intensive Care, Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden
| | - Erik von Oelreich
- Perioperative Medicine and Intensive Care, Karolinska University Hospital, Solna, Sweden
- Section of Anesthesiology and Intensive Care Medicine, Department of Physiology and Pharmacology, Karolinska Institutet, Solna, Sweden
| | - Diddi Fors
- Department of Surgical Sciences, Anaesthesiology and Intensive Care Medicine, Uppsala University, Uppsala, Sweden
| |
Collapse
|
3
|
Frerichs I, Schädler D, Becher T. Setting positive end-expiratory pressure by using electrical impedance tomography. Curr Opin Crit Care 2024; 30:43-52. [PMID: 38085866 DOI: 10.1097/mcc.0000000000001117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
PURPOSE OF REVIEW This review presents the principles and possibilities of setting positive end-expiratory pressure (PEEP) using electrical impedance tomography (EIT). It summarizes the major findings of recent studies where EIT was applied to monitor the effects of PEEP on regional lung function and to guide the selection of individualized PEEP setting. RECENT FINDINGS The most frequent approach of utilizing EIT for the assessment of PEEP effects and the PEEP setting during the time period from January 2022 till June 2023 was based on the analysis of pixel tidal impedance variation, typically acquired during stepwise incremental and/or decremental PEEP variation. The most common EIT parameters were the fraction of ventilation in various regions of interest, global inhomogeneity index, center of ventilation, silent spaces, and regional compliance of the respiratory system. The studies focused mainly on the spatial and less on the temporal distribution of ventilation. Contrast-enhanced EIT was applied in a few studies for the estimation of ventilation/perfusion matching. SUMMARY The availability of commercial EIT devices resulted in an increase in clinical studies using this bedside imaging technology in neonatal, pediatric and adult critically ill patients. The clinical interest in EIT became evident but the potential of this method in clinical decision-making still needs to be fully exploited.
Collapse
Affiliation(s)
- Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | | | | |
Collapse
|
4
|
佘 林, 周 睿, 潘 盼, 李 展, 刘 继, 谢 菲. [Research progress on electrical impedance tomography in pulmonary perfusion]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2023; 40:1249-1254. [PMID: 38151950 PMCID: PMC10753299 DOI: 10.7507/1001-5515.202302025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 10/04/2023] [Indexed: 12/29/2023]
Abstract
Electrical impedance tomography (EIT) is an emerging technology for real-time monitoring based on the impedance differences of different tissues and organs in the human body. It has been initially applied in clinical research as well as disease diagnosis and treatment. Lung perfusion refers to the blood flow perfusion function of lung tissue, and the occurrence and development of many diseases are closely related to lung perfusion. Therefore, real-time monitoring of lung perfusion is particularly important. The application and development of EIT further promote the monitoring of lung perfusion, and related research has made great progress. This article reviews the principles of EIT imaging, lung perfusion imaging methods, and their clinical applications in recent years, with the aim of providing assistance to clinical and scientific researchers.
Collapse
Affiliation(s)
- 林君 佘
- 河南中医药大学 第一临床医学院(郑州 450000)The First Clinical Medical College, Henan University of Traditional Chinese Medicine, Zhengzhou 450000, P. R. China
| | - 睿 周
- 河南中医药大学 第一临床医学院(郑州 450000)The First Clinical Medical College, Henan University of Traditional Chinese Medicine, Zhengzhou 450000, P. R. China
| | - 盼 潘
- 河南中医药大学 第一临床医学院(郑州 450000)The First Clinical Medical College, Henan University of Traditional Chinese Medicine, Zhengzhou 450000, P. R. China
| | - 展 李
- 河南中医药大学 第一临床医学院(郑州 450000)The First Clinical Medical College, Henan University of Traditional Chinese Medicine, Zhengzhou 450000, P. R. China
| | - 继红 刘
- 河南中医药大学 第一临床医学院(郑州 450000)The First Clinical Medical College, Henan University of Traditional Chinese Medicine, Zhengzhou 450000, P. R. China
| | - 菲 谢
- 河南中医药大学 第一临床医学院(郑州 450000)The First Clinical Medical College, Henan University of Traditional Chinese Medicine, Zhengzhou 450000, P. R. China
- 中国人民解放军总医院第一医学中心 呼吸与危重症医学科(北京 100091)Department of Respiratory and Critical Care Medicine, The First Medical Center of Chinese PLA General Hospital, Beijing 100091, P. R. China
| |
Collapse
|
5
|
Muders T, Hentze B, Leonhardt S, Putensen C. Evaluation of Different Contrast Agents for Regional Lung Perfusion Measurement Using Electrical Impedance Tomography: An Experimental Pilot Study. J Clin Med 2023; 12:jcm12082751. [PMID: 37109088 PMCID: PMC10143707 DOI: 10.3390/jcm12082751] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 03/22/2023] [Accepted: 04/03/2023] [Indexed: 04/29/2023] Open
Abstract
Monitoring regional blood flow distribution in the lungs appears to be useful for individually optimizing ventilation therapy. Electrical impedance tomography (EIT) can be used at the bedside for indicator-based regional lung perfusion measurement. Hypertonic saline is widely used as a contrast agent but could be problematic for clinical use due to potential side effects. In five ventilated healthy pigs, we investigated the suitability of five different injectable and clinically approved solutions as contrast agents for EIT-based lung perfusion measurement. Signal extraction success rate, signal strength, and image quality were analyzed after repeated 10 mL bolus injections during temporary apnea. The best results were obtained using NaCl 5.85% and sodium-bicarbonate 8.4% with optimal success rates (100%, each), the highest signal strengths (100 ± 25% and 64 ± 17%), and image qualities (r = 0.98 ± 0.02 and 0.95 ± 0.07). Iomeprol 400 mg/mL (non-ionic iodinated X-ray contrast medium) and Glucose 5% (non-ionic glucose solution) resulted in mostly well usable signals with above average success rates (87% and 89%), acceptable signal strength (32 ± 8% and 16 + 3%), and sufficient image qualities (r = 0.80 ± 0.19 and 0.72 ± 0.21). Isotonic balanced crystalloid solution failed due to a poor success rate (42%), low signal strength (10 ± 4%), and image quality (r = 0.43 ± 0.28). While Iomeprol might enable simultaneous EIT and X-ray measurements, glucose might help to avoid sodium and chloride overload. Further research should address optimal doses to balance reliability and potential side effects.
Collapse
Affiliation(s)
- Thomas Muders
- Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany
| | - Benjamin Hentze
- Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany
- Chair for Medical Information Technology, RWTH Aachen University, 52074 Aachen, Germany
| | - Steffen Leonhardt
- Chair for Medical Information Technology, RWTH Aachen University, 52074 Aachen, Germany
| | - Christian Putensen
- Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany
| |
Collapse
|
6
|
Mlček M, Borges JB, Otáhal M, Alcala GC, Hladík D, Kuriščák E, Tejkl L, Amato M, Kittnar O. Real-time effects of lateral positioning on regional ventilation and perfusion in an experimental model of acute respiratory distress syndrome. Front Physiol 2023; 14:1113568. [PMID: 37020459 PMCID: PMC10067565 DOI: 10.3389/fphys.2023.1113568] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Accepted: 03/01/2023] [Indexed: 03/22/2023] Open
Abstract
Low-volume lung injury encompasses local concentration of stresses in the vicinity of collapsed regions in heterogeneously ventilated lungs. We aimed to study the effects on ventilation and perfusion distributions of a sequential lateral positioning (30°) strategy using electrical impedance tomography imaging in a porcine experimental model of early acute respiratory distress syndrome (ARDS). We hypothesized that such strategy, including a real-time individualization of positive end-expiratory pressure (PEEP) whenever in lateral positioning, would provide attenuation of collapse in the dependent lung regions. A two-hit injury acute respiratory distress syndrome experimental model was established by lung lavages followed by injurious mechanical ventilation. Then, all animals were studied in five body positions in a sequential order, 15 min each: Supine 1; Lateral Left; Supine 2; Lateral Right; Supine 3. The following functional images were analyzed by electrical impedance tomography: ventilation distributions and regional lung volumes, and perfusion distributions. The induction of the acute respiratory distress syndrome model resulted in a marked fall in oxygenation along with low regional ventilation and compliance of the dorsal half of the lung (gravitational-dependent in supine position). Both the regional ventilation and compliance of the dorsal half of the lung greatly increased along of the sequential lateral positioning strategy, and maximally at its end. In addition, a corresponding improvement of oxygenation occurred. In conclusion, our sequential lateral positioning strategy, with sufficient positive end-expiratory pressure to prevent collapse of the dependent lung units during lateral positioning, provided a relevant diminution of collapse in the dorsal lung in a porcine experimental model of early acute respiratory distress syndrome.
Collapse
Affiliation(s)
- Mikuláš Mlček
- First Faculty of Medicine, Institute of Physiology, Charles University, Prague, Czechia
| | - João Batista Borges
- First Faculty of Medicine, Institute of Physiology, Charles University, Prague, Czechia
- *Correspondence: João Batista Borges,
| | - Michal Otáhal
- First Faculty of Medicine, Institute of Physiology, Charles University, Prague, Czechia
- Department of Anaesthesiology, Resuscitation and Intensive Medicine, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czechia
| | - Glasiele Cristina Alcala
- Pulmonology Division, Cardiopulmonary Department, Heart Institute, University of Sao Paulo, São Paulo, Brazil
| | - Dominik Hladík
- First Faculty of Medicine, Institute of Physiology, Charles University, Prague, Czechia
- Department of Anaesthesiology, Resuscitation and Intensive Medicine, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czechia
| | - Eduard Kuriščák
- First Faculty of Medicine, Institute of Physiology, Charles University, Prague, Czechia
| | - Leoš Tejkl
- First Faculty of Medicine, Institute of Physiology, Charles University, Prague, Czechia
| | - Marcelo Amato
- Pulmonology Division, Cardiopulmonary Department, Heart Institute, University of Sao Paulo, São Paulo, Brazil
| | - Otomar Kittnar
- First Faculty of Medicine, Institute of Physiology, Charles University, Prague, Czechia
| |
Collapse
|
7
|
Pennati F, Angelucci A, Morelli L, Bardini S, Barzanti E, Cavallini F, Conelli A, Di Federico G, Paganelli C, Aliverti A. Electrical Impedance Tomography: From the Traditional Design to the Novel Frontier of Wearables. SENSORS (BASEL, SWITZERLAND) 2023; 23:1182. [PMID: 36772222 PMCID: PMC9921522 DOI: 10.3390/s23031182] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/16/2023] [Accepted: 01/17/2023] [Indexed: 06/18/2023]
Abstract
Electrical impedance tomography (EIT) is a medical imaging technique based on the injection of a current or voltage pattern through electrodes on the skin of the patient, and on the reconstruction of the internal conductivity distribution from the voltages collected by the electrodes. Compared to other imaging techniques, EIT shows significant advantages: it does not use ionizing radiation, is non-invasive and is characterized by high temporal resolution. Moreover, its low cost and high portability make it suitable for real-time, bedside monitoring. However, EIT is also characterized by some technical limitations that cause poor spatial resolution. The possibility to design wearable devices based on EIT has recently given a boost to this technology. In this paper we reviewed EIT physical principles, hardware design and major clinical applications, from the classical to a wearable setup. A wireless and wearable EIT system seems a promising frontier of this technology, as it can both facilitate making clinical measurements and open novel scenarios to EIT systems, such as home monitoring.
Collapse
|
8
|
Zhang K, Li M, Liang H, Wang J, Yang F, Xu S, Abubakar A. Deep feature-domain matching for cardiac-related component separation from a chest electrical impedance tomography image series: proof-of-concept study. Physiol Meas 2022; 43. [PMID: 36265475 DOI: 10.1088/1361-6579/ac9c44] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 10/20/2022] [Indexed: 02/07/2023]
Abstract
Objectives.The cardiac-related component in chest electrical impedance tomography (EIT) measurement is of potential value to pulmonary perfusion monitoring and cardiac function measurement. In a spontaneous breathing case, cardiac-related signals experience serious interference from ventilation-related signals. Traditional cardiac-related signal-separation methods are usually based on certain features of signals. To further improve the separation accuracy, more comprehensive features of the signals should be exploited.Approach.We propose an unsupervised deep-learning method called deep feature-domain matching (DFDM), which exploits the feature-domain similarity of the desired signals and the breath-holding signals. This method is characterized by two sub-steps. In the first step, a novel Siamese network is designed and trained to learn common features of breath-holding signals; in the second step, the Siamese network is used as a feature-matching constraint between the separated signals and the breath-holding signals.Main results.The method is first tested using synthetic data, and the results show satisfactory separation accuracy. The method is then tested using the data of three patients with pulmonary embolism, and the consistency between the separated images and the radionuclide perfusion scanning images is checked qualitatively.Significance.The method uses a lightweight convolutional neural network for fast network training and inference. It is a potential method for dynamic cardiac-related signal separation in clinical settings.
Collapse
Affiliation(s)
- Ke Zhang
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology (BNRist), Institute for Precision Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| | - Maokun Li
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology (BNRist), Institute for Precision Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| | - Haiqing Liang
- TEDA International Cardiovascular Hospital, Tianjin 300457, People's Republic of China
| | - Juan Wang
- National Laboratory of Pattern Recognition (NLPR), Institute of Automation, Chinese Academy of Sciences, Beijing 100190, People's Republic of China
| | - Fan Yang
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology (BNRist), Institute for Precision Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| | - Shenheng Xu
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology (BNRist), Institute for Precision Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| | - Aria Abubakar
- Schlumberger, Houston, TX 77056, United States of America
| |
Collapse
|
9
|
Zhou R, He C, Chi Y, Yuan S, Tang B, Li Z, Li Q, He H, Long Y. Electrical impedance tomography to aid in the identification of hypoxemia etiology: Massive atelectasis or pneumothorax? A case report. Front Med (Lausanne) 2022; 9:970087. [PMID: 36117985 PMCID: PMC9481296 DOI: 10.3389/fmed.2022.970087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 08/18/2022] [Indexed: 11/24/2022] Open
Abstract
Background Bedside ultrasound is often used to determine the etiology of hypoxaemia, but not always with definitive results. This case reports the application of electrical impedance tomography (EIT) and saline injection to determine the etiology of hypoxaemia in a complex case that could not be identified by bedside ultrasound. The determination of the etiology of hypoxaemia by EIT and saline injection, regional ventilation and perfusion information can be used as a new clinical diagnostic method. Case presentation A post-cardiac surgery patient under prolonged mechanical ventilation for lung emphysema developed sudden hypoxemia in the intensive care unit (ICU). A line pattern and lung sliding sign abolishment were found in the left lung, but there was no evidence of a lung point sign on bedside ultrasound. Hence, the initial diagnosis was considered to be a massive pneumothorax. To further define the etiology, EIT and saline bolus were used to assess regional ventilation and perfusion. A massive ventilation defect was found in the left lung, in which regional perfusion was maintained, resulting in an intrapulmonary shunt in the left lung. Finally, the conjecture of a pneumothorax was ruled out considering the massive atelectasis. After the diagnosis was clarified, hypoxaemia was corrected by restorative ventilation of the left lung after changing the patient's posture and enhancing sputum drainage with chest physiotherapy. Conclusions This was the clinical case involving EIT and saline bolus to establish the differential diagnosis and guide clinical decisions for patients with acute hypoxemia. This study highlighted that combination regional ventilation, EIT perfusion, and saline bolus provided helpful information for determining the etiology of hypoxemia. The results of this study contribute to the development of emergency patient management.
Collapse
|
10
|
Zheng Z, Wu Z, Zhao R, Ni Y, Jing X, Gao S. A Review of EMG-, FMG-, and EIT-Based Biosensors and Relevant Human–Machine Interactivities and Biomedical Applications. BIOSENSORS 2022; 12:bios12070516. [PMID: 35884319 PMCID: PMC9313012 DOI: 10.3390/bios12070516] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/06/2022] [Accepted: 07/09/2022] [Indexed: 11/23/2022]
Abstract
Wearables developed for human body signal detection receive increasing attention in the current decade. Compared to implantable sensors, wearables are more focused on body motion detection, which can support human–machine interaction (HMI) and biomedical applications. In wearables, electromyography (EMG)-, force myography (FMG)-, and electrical impedance tomography (EIT)-based body information monitoring technologies are broadly presented. In the literature, all of them have been adopted for many similar application scenarios, which easily confuses researchers when they start to explore the area. Hence, in this article, we review the three technologies in detail, from basics including working principles, device architectures, interpretation algorithms, application examples, merits and drawbacks, to state-of-the-art works, challenges remaining to be solved and the outlook of the field. We believe the content in this paper could help readers create a whole image of designing and applying the three technologies in relevant scenarios.
Collapse
Affiliation(s)
| | | | | | | | | | - Shuo Gao
- Correspondence: ; Tel.: +86-18600737330
| |
Collapse
|
11
|
Santos TBR, Nakanishi RM, de Camargo EDLB, Amato MBP, Kaipio JP, Lima RG, Mueller JL. Improved resolution of D-bar images of ventilation using a Schur complement property and an anatomical atlas. Med Phys 2022; 49:4653-4670. [PMID: 35411573 PMCID: PMC9544658 DOI: 10.1002/mp.15669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 03/31/2022] [Accepted: 03/31/2022] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) is a nonionizing imaging technique for real-time imaging of ventilation of patients with respiratory distress. Cross-sectional dynamic images are formed by reconstructing the conductivity distribution from measured voltage data arising from applied alternating currents on electrodes placed circumferentially around the chest. Since the conductivity of lung tissue depends on air content, blood flow, and the presence of pathology, the dynamic images provide regional information about ventilation, pulsatile perfusion, and abnormalities. However, due to the ill-posedness of the inverse conductivity problem, EIT images have a coarse spatial resolution. One method of improving the resolution is to include prior information in the reconstruction. PURPOSE In this work, we propose a technique in which a statistical prior built from an anatomical atlas is used to postprocess EIT reconstructions of human chest data. The effectiveness of the method is demonstrated on data from two patients with cystic fibrosis. METHODS A direct reconstruction algorithm known as the D-bar method was used to compute a two-dimensional reconstruction of the conductivity distribution in the plane of the electrodes. Reconstructions using one step in an iterative (regularized) Newton's method were also computed for comparison. An anatomical atlas consisting of 1589 synthetic EIT images computed from X-ray computed tomography (CT) scans of 74 adult male subjects was computed for use as a statistical prior. The resolution of the D-bar images was then improved by maximizing the conditional probability density function of an image that is consistent with the a priori information and the statistical model. A new method to evaluate the accuracy of the EIT images using CT scans of the imaged patient as ground truth is presented. The novel approach is tested on data from two patients with cystic fibrosis. RESULTS AND CONCLUSIONS The D-bar images resulted in better structural similarity index measures (SSIM) and multiscale (MS) SSIM measures for both subjects using the mask or amplitude evaluation approach than the one-step (regularized) Newton's method. Further improvement was achieved using the Schur complement (SC) approach, with MS-SSIM values of 0.718 and 0.682 using SC evaluated with the mask and amplitude approach, respectively, for Patient 1, and MS-SSIM values of 0.726 and 0.692 using SC evaluated with the mask and amplitude approach, respectively, for Patient 2. The results from applying an anatomical atlas and statistical prior to EIT data from two patients with cystic fibrosis suggest that the spatial resolution of the EIT image can be improved to reveal pathology that may be difficult to discern in the original EIT image. The novel metric of evaluation is consistent with the appearance of improved spatial resolution and provides a new way to evaluate the accuracy of EIT reconstructions when a CT scan is available.
Collapse
Affiliation(s)
| | - Rafael Mikio Nakanishi
- Mechanical Engineering DepartmentPolytechnic School of the University of São PauloSão PauloSPBrazil
| | | | | | - Jari P. Kaipio
- Department of MathematicsUniversity of AucklandNew Zealand
- Department of Applied PhysicsUniversity of Eastern FinlandKuopioFinland
| | - Raul Gonzalez Lima
- Mechanical Engineering DepartmentPolytechnic School of the University of São PauloSão PauloSPBrazil
| | - Jennifer L. Mueller
- Department of Mathematics and School of Biomedical Engineering and the Department of Electrical and Computer EngineeringColorado State UniversityColoradoUSA
| |
Collapse
|
12
|
Abstract
OBJECTIVE To describe, through a narrative review, the physiologic principles underlying electrical impedance tomography, and its potential applications in managing acute respiratory distress syndrome (ARDS). To address the current evidence supporting its use in different clinical scenarios along the ARDS management continuum. DATA SOURCES We performed an online search in Pubmed to review articles. We searched MEDLINE, Cochrane Central Register, and clinicaltrials.gov for controlled trials databases. STUDY SELECTION Selected publications included case series, pilot-physiologic studies, observational cohorts, and randomized controlled trials. To describe the rationale underlying physiologic principles, we included experimental studies. DATA EXTRACTION Data from relevant publications were reviewed, analyzed, and its content summarized. DATA SYNTHESIS Electrical impedance tomography is an imaging technique that has aided in understanding the mechanisms underlying multiple interventions used in ARDS management. It has the potential to monitor and predict the response to prone positioning, aid in the dosage of flow rate in high-flow nasal cannula, and guide the titration of positive-end expiratory pressure during invasive mechanical ventilation. The latter has been demonstrated to improve physiologic and mechanical parameters correlating with lung recruitment. Similarly, its use in detecting pneumothorax and harmful patient-ventilator interactions such as pendelluft has been proven effective. Nonetheless, its impact on clinically meaningful outcomes remains to be determined. CONCLUSIONS Electrical impedance tomography is a potential tool for the individualized management of ARDS throughout its different stages. Clinical trials should aim to determine whether a specific approach can improve clinical outcomes in ARDS management.
Collapse
|
13
|
Electrical impedance tomography in the adult intensive care unit. Curr Opin Crit Care 2022; 28:292-301. [DOI: 10.1097/mcc.0000000000000936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
Ke XY, Hou W, Huang Q, Hou X, Bao XY, Kong WX, Li CX, Qiu YQ, Hu SY, Dong LH. Advances in electrical impedance tomography-based brain imaging. Mil Med Res 2022; 9:10. [PMID: 35227324 PMCID: PMC8883715 DOI: 10.1186/s40779-022-00370-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 02/08/2022] [Indexed: 11/10/2022] Open
Abstract
Novel advances in the field of brain imaging have enabled the unprecedented clinical application of various imaging modalities to facilitate disease diagnosis and treatment. Electrical impedance tomography (EIT) is a functional imaging technique that measures the transfer impedances between electrodes on the body surface to estimate the spatial distribution of electrical properties of tissues. EIT offers many advantages over other neuroimaging technologies, which has led to its potential clinical use. This qualitative review provides an overview of the basic principles, algorithms, and system composition of EIT. Recent advances in the field of EIT are discussed in the context of epilepsy, stroke, brain injuries and edema, and other brain diseases. Further, we summarize factors limiting the development of brain EIT and highlight prospects for the field. In epilepsy imaging, there have been advances in EIT imaging depth, from cortical to subcortical regions. In stroke research, a bedside EIT stroke monitoring system has been developed for clinical practice, and data support the role of EIT in multi-modal imaging for diagnosing stroke. Additionally, EIT has been applied to monitor the changes in brain water content associated with cerebral edema, enabling the early identification of brain edema and the evaluation of mannitol dehydration. However, anatomically realistic geometry, inhomogeneity, cranium completeness, anisotropy and skull type, etc., must be considered to improve the accuracy of EIT modeling. Thus, the further establishment of EIT as a mature and routine diagnostic technique will necessitate the accumulation of more supporting evidence.
Collapse
Affiliation(s)
- Xi-Yang Ke
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Wei Hou
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Qi Huang
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Jiangsu, China
| | - Xue Hou
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Xue-Ying Bao
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Wei-Xuan Kong
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China
| | - Cheng-Xiang Li
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Yu-Qi Qiu
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Si-Yi Hu
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Jiangsu, China.
| | - Li-Hua Dong
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China. .,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China. .,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China.
| |
Collapse
|
15
|
Cheng KS, Su PL, Ko YF. Separation of Heart and Lung-related Signals in Electrical Impedance Tomography Using Empirical Mode Decomposition. Curr Med Imaging 2022; 18:1396-1415. [PMID: 35570528 PMCID: PMC9903293 DOI: 10.2174/1573405618666220513130834] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 03/13/2022] [Accepted: 03/17/2022] [Indexed: 01/25/2023]
Abstract
BACKGROUND Electrical impedance tomography (EIT) can be used for continuous monitoring of pulmonary ventilation. However, no proper method has been developed for the separation of pulmonary ventilation and perfusion signals and the measurement of the associated ventilation/ perfusion (V/Q) ratio. Previously, various methods have been used to extract these components; however, these have not been able to effectively separate and validate cardiac- and pulmonary- related images. AIMS This study aims at validating and developing a novel method to separate cardiac- and pulmonary- related components based on the EIT simulation field of view and to simultaneously reconstruct the individual images instantly. METHODS Our approach combines the advantages of the principal component analysis (PCA) and processes that originally measure EIT data instead of handling a series of EIT images, thus introducing the empirical mode decomposition (EMD). The PCA template functions for cardiacrelated imaging and intrinsic mode functions (IMFs) of EMD for lung-related imaging are then adapted to input signals. RESULTS The proposed method enables the separation of cardiac- and lung-related components by adjusting the proportion of the key components related to lung imaging, which are the fourth component (PC4) and the first component (IMF1) in PCA- and EMD-based methods, respectively. The preliminary results on the application of the method to real human EIT data revealed the consistently better performance and optimal computation compared with previous methods. CONCLUSION This study proposes a novel method for applying EIT to evaluate the best time of V/Q matching on the cardiovascular and respiratory systems; this aspect can be investigated in future research.
Collapse
Affiliation(s)
- Kuo-Sheng Cheng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan
| | - Po-Lan Su
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan;,Department of Internal Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 701, Taiwan
| | - Yen-Fen Ko
- College of Biomedical Engineering, China Medical University, Taichung 404, Taiwan,Address correspondence to this author at the College of Biomedical Engineering, China Medical University No.91, Xueshi Road, Taichung 404, Taiwan; Tel: 886-9-33449872; Fax: 886-6-2343270; E-mail:
| |
Collapse
|
16
|
Xu M, He H, Long Y. Lung Perfusion Assessment by Bedside Electrical Impedance Tomography in Critically Ill Patients. Front Physiol 2021; 12:748724. [PMID: 34721072 PMCID: PMC8548642 DOI: 10.3389/fphys.2021.748724] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 09/13/2021] [Indexed: 12/02/2022] Open
Abstract
As a portable, radiation-free imaging modality, electrical impedance tomography (EIT) technology has shown promise in the bedside visual assessment of lung perfusion distribution in critically ill patients. The two main methods of EIT for assessing lung perfusion are the pulsatility and conductivity contrast (saline) bolus method. Increasing attention is being paid to the saline bolus EIT method in the evaluation of regional pulmonary perfusion in clinical practice. This study seeks to provide an overview of experimental and clinical studies with the aim of clarifying the progress made in the use of the saline bolus EIT method. Animal studies revealed that the saline bolus EIT method presented good consistency with single-photon emission CT (SPECT) in the evaluation of lung regional perfusion changes in various pathological conditions. Moreover, the saline bolus EIT method has been applied to assess the lung perfusion in a pulmonary embolism and the effect of positive end-expiratory pressure (PEEP) on regional ventilation/perfusion ratio (V/Q) and acute respiratory distress syndrome (ARDS) in several clinical studies. The implementation of saline boluses, data analyses, precision, and cutoff values varied among different studies, and a consensus must be reached regarding the clinical application of the saline bolus EIT method. Further study is required to validate the impact of the described saline bolus EIT method on decision-making, therapeutic management, and outcomes in critically ill patients.
Collapse
Affiliation(s)
- Mengru Xu
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Critical Care Medicine, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Huaiwu He
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Critical Care Medicine, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Yun Long
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Critical Care Medicine, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| |
Collapse
|
17
|
Maciejewski D, Putowski Z, Czok M, Krzych ŁJ. Electrical impedance tomography as a tool for monitoring mechanical ventilation. An introduction to the technique. Adv Med Sci 2021; 66:388-395. [PMID: 34371248 DOI: 10.1016/j.advms.2021.07.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 05/27/2021] [Accepted: 07/28/2021] [Indexed: 02/02/2023]
Abstract
Electrical impedance tomography (EIT) is a non-invasive, radiation-free method of diagnostics imaging, allowing for a bedside, real-time dynamic assessment of lung function. It stands as an alternative for other imagining methods, such as computed tomography (CT) or ultrasound. Even though the technique is rather novel, it has a wide variety of possible applications. In the era of modern mechanical ventilation, a dynamic assessment of patient's respiratory condition appears to fulfil the idea of personalized treatment. Additionally, an increasing frequency of respiratory failure among intensive care populations raises demand for improved monitoring tools. This review aims to raise awareness and presents possible implications for the use of EIT in the intensive care setting.
Collapse
Affiliation(s)
- Dariusz Maciejewski
- Department of Anesthesiology and Intensive Therapy, Regional Hospital in Bielsko-Biala, Bielsko-Biala, Poland
| | - Zbigniew Putowski
- Students' Scientific Society, Department of Anesthesiology and Intensive Care, School of Medicine in Katowice, Medical University of Silesia, Katowice, Poland.
| | - Marcelina Czok
- Students' Scientific Society, Department of Anesthesiology and Intensive Care, School of Medicine in Katowice, Medical University of Silesia, Katowice, Poland
| | - Łukasz J Krzych
- Students' Scientific Society, Department of Anesthesiology and Intensive Care, School of Medicine in Katowice, Medical University of Silesia, Katowice, Poland
| |
Collapse
|
18
|
He H, Chi Y, Long Y, Yuan S, Zhang R, Yang Y, Frerichs I, Möller K, Fu F, Zhao Z. Three broad classifications of acute respiratory failure etiologies based on regional ventilation and perfusion by electrical impedance tomography: a hypothesis-generating study. Ann Intensive Care 2021; 11:134. [PMID: 34453622 PMCID: PMC8401348 DOI: 10.1186/s13613-021-00921-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 08/19/2021] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND The aim of this study was to validate whether regional ventilation and perfusion data measured by electrical impedance tomography (EIT) with saline bolus could discriminate three broad acute respiratory failure (ARF) etiologies. METHODS Perfusion image was generated from EIT-based impedance-time curves caused by 10 ml 10% NaCl injection during a respiratory hold. Ventilation image was captured before the breath holding period under regular mechanical ventilation. DeadSpace%, Shunt% and VQMatch% were calculated based on lung perfusion and ventilation images. Ventilation and perfusion maps were divided into four cross-quadrants (lower left and right, upper left and right). Regional distribution defects of each quadrant were scored as 0 (distribution% ≥ 15%), 1 (15% > distribution% ≥ 10%) and 2 (distribution% < 10%). Data percentile distributions in the control group and clinical simplicity were taken into consideration when defining the scores. Overall defect scores (DefectV, DefectQ and DefectV+Q) were the sum of four cross-quadrants of the corresponding images. RESULTS A total of 108 ICU patients were prospectively included: 93 with ARF and 15 without as a control. PaO2/FiO2 was significantly correlated with VQMatch% (r = 0.324, P = 0.001). Three broad etiologies of ARF were identified based on clinical judgment: pulmonary embolism-related disease (PED, n = 14); diffuse lung involvement disease (DLD, n = 21) and focal lung involvement disease (FLD, n = 58). The PED group had a significantly higher DeadSpace% [40(24)% vs. 14(15)%, PED group vs. the rest of the subjects; median(interquartile range); P < 0.0001] and DefectQ score than the other groups [1(1) vs. 0(1), PED vs. the rest; P < 0.0001]. The DLD group had a significantly lower DefectV+Q score than the PED and FLD groups [0(1) vs. 2.5(2) vs. 3(3), DLD vs. PED vs. FLD; P < 0.0001]. The FLD group had a significantly higher DefectV score than the other groups [2(2) vs. 0(1), FLD vs. the rest; P < 0.0001]. The area under the receiver operating characteristic (AUC) for using DeadSpace% to identify PED was 0.894 in all ARF patients. The AUC for using the DefectV+Q score to identify DLD was 0.893. The AUC for using the DefectV score to identify FLD was 0.832. CONCLUSIONS Our study showed that it was feasible to characterize three broad etiologies of ARF with EIT-based regional ventilation and perfusion. Further study is required to validate clinical applicability of this method. Trial registration clinicaltrials, NCT04081142. Registered 9 September 2019-retrospectively registered, https://clinicaltrials.gov/show/NCT04081142 .
Collapse
Affiliation(s)
- Huaiwu He
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Yi Chi
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Yun Long
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China.
| | - Siyi Yuan
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Rui Zhang
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Yingying Yang
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center of Schleswig-Holstein Campus Kiel, Kiel, Germany
| | - Knut Möller
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Feng Fu
- Department of Biomedical Engineering, Fourth Military Medical University, 169 Changle Xi Rd, Xi'an, China
| | - Zhanqi Zhao
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany. .,Department of Biomedical Engineering, Fourth Military Medical University, 169 Changle Xi Rd, Xi'an, China.
| |
Collapse
|
19
|
Hentze B, Muders T, Hoog Antink C, Putensen C, Larsson A, Hedenstierna G, Walter M, Leonhardt S. A model-based source separation algorithm for lung perfusion imaging using electrical impedance tomography. Physiol Meas 2021; 42. [PMID: 34167091 DOI: 10.1088/1361-6579/ac0e84] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 06/24/2021] [Indexed: 11/11/2022]
Abstract
Objective. Electrical impedance tomography (EIT) for lung perfusion imaging is attracting considerable interest in intensive care, as it might open up entirely new ways to adjust ventilation therapy. A promising technique is bolus injection of a conductive indicator to the central venous catheter, which yields the indicator-based signal (IBS). Lung perfusion images are then typically obtained from the IBS using the maximum slope technique. However, the low spatial resolution of EIT results in a partial volume effect (PVE), which requires further processing to avoid regional bias.Approach. In this work, we repose the extraction of lung perfusion images from the IBS as a source separation problem to account for the PVE. We then propose a model-based algorithm, called gamma decomposition (GD), to derive an efficient solution. The GD algorithm uses a signal model to transform the IBS into a parameter space where the source signals of heart and lung are separable by clustering in space and time. Subsequently, it reconstructs lung model signals from which lung perfusion images are unambiguously extracted.Main results. We evaluate the GD algorithm on EIT data of a prospective animal trial with eight pigs. The results show that it enables lung perfusion imaging using EIT at different stages of regional impairment. Furthermore, parameters of the source signals seem to represent physiological properties of the cardio-pulmonary system.Significance. This work represents an important advance in IBS processing that will likely reduce bias of EIT perfusion images and thus eventually enable imaging of regional ventilation/perfusion (V/Q) ratio.
Collapse
Affiliation(s)
- Benjamin Hentze
- Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany.,Department of Anaesthesiology and Intensive Care Medicine, University of Bonn, Venusberg-Campus 1, 53127 Bonn, Germany
| | - Thomas Muders
- Department of Anaesthesiology and Intensive Care Medicine, University of Bonn, Venusberg-Campus 1, 53127 Bonn, Germany
| | - Christoph Hoog Antink
- Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany.,Biomedical Engineering, TU Darmstadt, Darmstadt, Germany
| | - Christian Putensen
- Department of Anaesthesiology and Intensive Care Medicine, University of Bonn, Venusberg-Campus 1, 53127 Bonn, Germany
| | - Anders Larsson
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | | | - Marian Walter
- Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Steffen Leonhardt
- Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| |
Collapse
|
20
|
Pigatto AV, Kao TJ, Mueller JL, Baker CD, DeBoer EM, Kupfer O. Electrical impedance tomography detects changes in ventilation after airway clearance in spinal muscular atrophy type I. Respir Physiol Neurobiol 2021; 294:103773. [PMID: 34400355 DOI: 10.1016/j.resp.2021.103773] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2020] [Revised: 04/06/2021] [Accepted: 08/05/2021] [Indexed: 11/18/2022]
Abstract
The effect of mechanical insufflation-exsufflation (MIE) for airway clearance in patients with spinal muscular atrophy type I (SMA-I) on the distribution of ventilation in the lung is unknown, as is the duration of its beneficial effects. A pilot study to investigate the feasibility of using three dimensional (3-D) electrical impedance tomography (EIT) images to estimate lung volumes pre- and post-MIE for assessing the effectiveness of mechanical insufflation-exsufflation (MIE) was conducted in 6 pediatric patients with SMA-I in the neuromuscular clinic at Children's Hospital Colorado. EIT data were collected before, during, and after the MIE procedure on two rows of 16 electrodes placed around the chest. Lung volumes were computed from the images and compared before, during, and after the MIE procedure to assess the ability of EIT to estimate changes in lung volume during insufflation and exsufflation. Images of pulsatile pulmonary perfusion were computed in subjects able to perform breath-holding. In four of the six subjects, lung volumes during tidal breathing increased after MIE (average change from pre to post MIE was 58.8±55.1 mL). The time-dependent plots of lung volume computed from the EIT data clearly show when the MIE device insufflates and exsufflates air and the rest periods between mechanical coughs. Images of pulmonary pulsatile perfusion were computed from data collected during breathing pauses. The results suggest that EIT holds promise for estimating lung volumes and ventilation/perfusion mismatch, both of which are useful for assessing the effectiveness of MIE in clearing mucus plugs.
Collapse
Affiliation(s)
- Andre Viera Pigatto
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, United States
| | - Tzu-Jen Kao
- GE Research, Niskayuna, NY 12309, United States
| | - Jennifer L Mueller
- School of Biomedical Engineering and Department of Mathematics, Colorado State University, Fort Collins, CO 80523, United States.
| | - Christopher D Baker
- Department of Pediatrics, Section of Pulmonary Medicine, University of Colorado School of Medicine, Aurora, CO 80045, United States
| | - Emily M DeBoer
- Department of Pediatrics, Section of Pulmonary Medicine, University of Colorado School of Medicine, Aurora, CO 80045, United States
| | - Oren Kupfer
- Department of Pediatrics, Section of Pulmonary Medicine, University of Colorado School of Medicine, Aurora, CO 80045, United States
| |
Collapse
|
21
|
Spinelli E, Kircher M, Stender B, Ottaviani I, Basile MC, Marongiu I, Colussi G, Grasselli G, Pesenti A, Mauri T. Unmatched ventilation and perfusion measured by electrical impedance tomography predicts the outcome of ARDS. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2021; 25:192. [PMID: 34082795 PMCID: PMC8173510 DOI: 10.1186/s13054-021-03615-4] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Accepted: 05/21/2021] [Indexed: 12/30/2022]
Abstract
Background In acute respiratory distress syndrome (ARDS), non-ventilated perfused regions coexist with non-perfused ventilated regions within lungs. The number of unmatched regions might reflect ARDS severity and affect the risk of ventilation-induced lung injury. Despite pathophysiological relevance, unmatched ventilation and perfusion are not routinely assessed at the bedside. The aims of this study were to quantify unmatched ventilation and perfusion at the bedside by electrical impedance tomography (EIT) investigating their association with mortality in patients with ARDS and to explore the effects of positive end-expiratory pressure (PEEP) on unmatched ventilation and perfusion in subgroups of patients with different ARDS severity based on PaO2/FiO2 and compliance. Methods Prospective observational study in 50 patients with mild (36%), moderate (46%), and severe (18%) ARDS under clinical ventilation settings. EIT was applied to measure the regional distribution of ventilation and perfusion using central venous bolus of saline 5% during end-inspiratory pause. We defined unmatched units as the percentage of only ventilated units plus the percentage of only perfused units. Results Percentage of unmatched units was significantly higher in non-survivors compared to survivors (32[27–47]% vs. 21[17–27]%, p < 0.001). Percentage of unmatched units was an independent predictor of mortality (OR 1.22, 95% CI 1.07–1.39, p = 0.004) with an area under the ROC curve of 0.88 (95% CI 0.79–0.97, p < 0.001). The percentage of ventilation to the ventral region of the lung was higher than the percentage of ventilation to the dorsal region (32 [27–38]% vs. 18 [13–21]%, p < 0.001), while the opposite was true for perfusion (28 [22–38]% vs. 36 [32–44]%, p < 0.001). Higher percentage of only perfused units was correlated with lower dorsal ventilation (r = − 0.486, p < 0.001) and with lower PaO2/FiO2 ratio (r = − 0.293, p = 0.039). Conclusions EIT allows bedside assessment of unmatched ventilation and perfusion in mechanically ventilated patients with ARDS. Measurement of unmatched units could identify patients at higher risk of death and could guide personalized treatment.
Collapse
Affiliation(s)
- Elena Spinelli
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122, Milan, Italy
| | - Michael Kircher
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | | | - Irene Ottaviani
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122, Milan, Italy
| | - Maria C Basile
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122, Milan, Italy
| | - Ines Marongiu
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Giulia Colussi
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122, Milan, Italy
| | - Giacomo Grasselli
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122, Milan, Italy.,Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Antonio Pesenti
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122, Milan, Italy.,Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Tommaso Mauri
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122, Milan, Italy. .,Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
| |
Collapse
|
22
|
Abstract
PURPOSE OF REVIEW Among noninvasive lung imaging techniques that can be employed at the bedside electrical impedance tomography (EIT) and lung ultrasound (LUS) can provide dynamic, repeatable data on the distribution regional lung ventilation and response to therapeutic manoeuvres.In this review, we will provide an overview on the rationale, basic functioning and most common applications of EIT and Point of Care Ultrasound (PoCUS, mainly but not limited to LUS) in the management of mechanically ventilated patients. RECENT FINDINGS The use of EIT in clinical practice is supported by several studies demonstrating good correlation between impedance tomography data and other validated methods of assessing lung aeration during mechanical ventilation. Similarly, LUS also correlates with chest computed tomography in assessing lung aeration, its changes and several pathological conditions, with superiority over other techniques. Other PoCUS applications have shown to effectively complement the LUS ultrasound assessment of the mechanically ventilated patient. SUMMARY Bedside techniques - such as EIT and PoCUS - are becoming standards of the care for mechanically ventilated patients to monitor the changes in lung aeration, ventilation and perfusion in response to treatment and to assess weaning from mechanical ventilation.
Collapse
|
23
|
Yuan S, He H, Long Y, Chi Y, Frerichs I, Zhao Z. Rapid dynamic bedside assessment of pulmonary perfusion defect by electrical impedance tomography in a patient with acute massive pulmonary embolism. Pulm Circ 2021; 11:2045894020984043. [PMID: 33532059 PMCID: PMC7829466 DOI: 10.1177/2045894020984043] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Accepted: 06/07/2020] [Indexed: 12/21/2022] Open
Abstract
Several animal studies have shown that regional lung perfusion could be
effectively estimated by the hypertonic saline contrast electrical impedance
tomography method. Here, we reported an application of this method to
dynamically assess regional pulmonary perfusion defect in a patient with acute
massive pulmonary embolism. A 68-year-old man experienced sudden dyspnea and
cardiac arrest during out-of-bed physical activity on the first day after
partial mediastinal tumor resection. Acute pulmonary embolism was suspected due
to acute enlargement of right heart and fixed inferior venous cava measured with
bedside ultrasound. The computed tomography pulmonary angiography further
confirmed large embolism in both left and right main pulmonary arteries and
branches. The regional time impedance curves, which were obtained by a bolus of
10 ml 10% NaCl through the central venous catheter, were then analyzed to
quantitatively assess regional perfusion. Normal ventilation distribution with
massive defects in regional perfusion in both lungs was observed, leading to a
ventilation–perfusion mismatch and low oxygenation index
(PaO2/FiO2 = 86 mmHg) at the first day of pulmonary embolism. The
anticoagulation was performed with heparin, and the patient’s condition (such as
shock, dyspnea, hypoxemia, etc.), regional lung perfusion defect, and
ventilation–perfusion mismatch continuously improved in the following days. In
conclusion, this case implies that electrical impedance tomography might have
the potential to assess and monitor regional perfusion for rapid diagnosis of
fatal pulmonary embolism in clinical practice.
Collapse
Affiliation(s)
- Siyi Yuan
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
| | - Huaiwu He
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
| | - Yun Long
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
| | - Yi Chi
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
| | - Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center of Schleswig-Holstein, Kiel, Germany
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.,Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|
24
|
Kircher M, Elke G, Stender B, Hernandez Mesa M, Schuderer F, Dossel O, Fuld MK, Halaweish AF, Hoffman EA, Weiler N, Frerichs I. Regional Lung Perfusion Analysis in Experimental ARDS by Electrical Impedance and Computed Tomography. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:251-261. [PMID: 32956046 DOI: 10.1109/tmi.2020.3025080] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Electrical impedance tomography is clinically used to trace ventilation related changes in electrical conductivity of lung tissue. Estimating regional pulmonary perfusion using electrical impedance tomography is still a matter of research. To support clinical decision making, reliable bedside information of pulmonary perfusion is needed. We introduce a method to robustly detect pulmonary perfusion based on indicator-enhanced electrical impedance tomography and validate it by dynamic multidetector computed tomography in two experimental models of acute respiratory distress syndrome. The acute injury was induced in a sublobar segment of the right lung by saline lavage or endotoxin instillation in eight anesthetized mechanically ventilated pigs. For electrical impedance tomography measurements, a conductive bolus (10% saline solution) was injected into the right ventricle during breath hold. Electrical impedance tomography perfusion images were reconstructed by linear and normalized Gauss-Newton reconstruction on a finite element mesh with subsequent element-wise signal and feature analysis. An iodinated contrast agent was used to compute pulmonary blood flow via dynamic multidetector computed tomography. Spatial perfusion was estimated based on first-pass indicator dilution for both electrical impedance and multidetector computed tomography and compared by Pearson correlation and Bland-Altman analysis. Strong correlation was found in dorsoventral (r = 0.92) and in right-to-left directions (r = 0.85) with good limits of agreement of 8.74% in eight lung segments. With a robust electrical impedance tomography perfusion estimation method, we found strong agreement between multidetector computed and electrical impedance tomography perfusion in healthy and regionally injured lungs and demonstrated feasibility of electrical impedance tomography perfusion imaging.
Collapse
|
25
|
Ravagli E, Mastitskaya S, Thompson N, Iacoviello F, Shearing PR, Perkins J, Gourine AV, Aristovich K, Holder D. Imaging fascicular organization of rat sciatic nerves with fast neural electrical impedance tomography. Nat Commun 2020; 11:6241. [PMID: 33288760 PMCID: PMC7721735 DOI: 10.1038/s41467-020-20127-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Accepted: 11/13/2020] [Indexed: 02/06/2023] Open
Abstract
Imaging compound action potentials (CAPs) in peripheral nerves could help avoid side effects in neuromodulation by selective stimulation of identified fascicles. Existing methods have low resolution, limited imaging depth, or are invasive. Fast neural electrical impedance tomography (EIT) allows fascicular CAP imaging with a resolution of <200 µm, <1 ms using a non-penetrating flexible nerve cuff electrode array. Here, we validate EIT imaging in rat sciatic nerve by comparison to micro-computed tomography (microCT) and histology with fluorescent dextran tracers. With EIT, there are reproducible localized changes in tissue impedance in response to stimulation of individual fascicles (tibial, peroneal and sural). The reconstructed EIT images correspond to microCT scans and histology, with significant separation between the fascicles (p < 0.01). The mean fascicle position is identified with an accuracy of 6% of nerve diameter. This suggests fast neural EIT can reliably image the functional fascicular anatomy of the nerves and so aid selective neuromodulation.
Collapse
Affiliation(s)
- Enrico Ravagli
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Svetlana Mastitskaya
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK.
| | - Nicole Thompson
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Francesco Iacoviello
- Electrochemical Innovation Laboratory, Department of Chemical Engineering, University College London, London, UK
| | - Paul R Shearing
- Electrochemical Innovation Laboratory, Department of Chemical Engineering, University College London, London, UK
| | - Justin Perkins
- Clinical Science and Services, Royal Veterinary College, Hawkshead Lane, Hatfield, UK
| | - Alexander V Gourine
- Centre for Cardiovascular and Metabolic Neuroscience, Department of Neuroscience, Physiology and Pharmacology, University College London, London, UK
| | - Kirill Aristovich
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - David Holder
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| |
Collapse
|
26
|
Sang L, Zhao Z, Lin Z, Liu X, Zhong N, Li Y. A narrative review of electrical impedance tomography in lung diseases with flow limitation and hyperinflation: methodologies and applications. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:1688. [PMID: 33490200 PMCID: PMC7812189 DOI: 10.21037/atm-20-4984] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Electrical impedance tomography (EIT) is a functional radiation-free imaging technique that measures regional lung ventilation distribution by calculating the impedance changes in the corresponding regions. The aim of the present review was to summarize the current literature concerning the methodologies and applications of EIT in lung diseases with flow limitation and hyperinflation. PubMed was searched up to May 2020 to identify studies investigating the use of EIT in patients with asthma, bronchiectasis, bronchitis, bronchiolitis, chronic obstructive pulmonary disease, and cystic fibrosis. The extracted data included study design, EIT methodologies, interventions, validation and comparators, population characteristics, and key findings. Of the 44 included studies, seven were related to simulation, animal experimentation, or reconstruction algorithm development with evaluation on patients; 27 studies had the primary objective of validating EIT technique and measures including regional ventilation distribution, regional EIT-spirometry parameters, end-expiratory lung impedance, and regional time constants; and 10 studies had the primary objective of applying EIT to monitor the response to therapeutic interventions, including various ventilation supports, patient repositioning, and airway suctioning. In pediatric and adult patients, EIT has been successfully validated for assessing spatial and temporal ventilation distribution, measuring changes in lung volume and flow, and studying regional respiratory mechanics. EIT has also demonstrated potential as an alternative or supplement to well-established measurement modalities (e.g., conventional pulmonary function testing) to monitor the progression of obstructive lung diseases, although the existing literature lacks prediction values as references and lacks clinical outcome evidence.
Collapse
Affiliation(s)
- Ling Sang
- State Key Laboratory of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou Medical University, the First Affiliated Hospital of Guangzhou Medical University, Department of Crit Care Med, Guangzhou, China
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.,Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Zhimin Lin
- State Key Laboratory of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou Medical University, the First Affiliated Hospital of Guangzhou Medical University, Department of Crit Care Med, Guangzhou, China
| | - Xiaoqing Liu
- State Key Laboratory of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou Medical University, the First Affiliated Hospital of Guangzhou Medical University, Department of Crit Care Med, Guangzhou, China
| | - Nanshan Zhong
- State Key Laboratory of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou Medical University, the First Affiliated Hospital of Guangzhou Medical University, Department of Crit Care Med, Guangzhou, China
| | - Yimin Li
- State Key Laboratory of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou Medical University, the First Affiliated Hospital of Guangzhou Medical University, Department of Crit Care Med, Guangzhou, China
| |
Collapse
|
27
|
He H, Long Y, Frerichs I, Zhao Z. Detection of Acute Pulmonary Embolism by Electrical Impedance Tomography and Saline Bolus Injection. Am J Respir Crit Care Med 2020; 202:881-882. [PMID: 32469613 DOI: 10.1164/rccm.202003-0554im] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Affiliation(s)
- Huaiwu He
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Yun Long
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center of Schleswig-Holstein Campus Kiel, Kiel, Germany
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China; and.,Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|
28
|
Borges JB, Alcala GC, Mlček M. A Step Forward toward a Bedside and Timely Monitoring of Regional [Formula: see text]/[Formula: see text] Matching. Am J Respir Crit Care Med 2020; 202:1342-1344. [PMID: 32833499 PMCID: PMC7667916 DOI: 10.1164/rccm.202007-2896ed] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Affiliation(s)
| | | | - Mikuláš Mlček
- Institute of PhysiologyCharles UniversityPrague, Czech Republicand
| |
Collapse
|
29
|
Zhang K, Guo R, Li M, Yang F, Xu S, Abubakar A. Supervised Descent Learning for Thoracic Electrical Impedance Tomography. IEEE Trans Biomed Eng 2020; 68:1360-1369. [PMID: 32997620 DOI: 10.1109/tbme.2020.3027827] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE The absolute image reconstruction problem of electrical impedance tomography (EIT) is ill-posed. Traditional methods usually solve a nonlinear least squares problem with some kind of regularization. These methods suffer from low accuracy, poor anti-noise performance, and long computation time. Besides, the integration of a priori information is not very flexible. This work tries to solve EIT inverse problem using a machine learning algorithm for the application of thorax imaging. METHODS We developed the supervised descent learning EIT (SDL-EIT) inversion algorithm based on the idea of supervised descent method (SDM). The algorithm approximates the mapping from measured data to the conductivity image by a series of descent directions learned from training samples. We designed a training data set in which the thorax contour, and some general structure of lungs, and heart are embedded. The algorithm is implemented in both two-, and three-dimensional cases, and is evaluated using synthetic, and measured thoracic data. Results, and conclusion: For synthetic data, SDL-EIT shows better accuracy, and anti-noise performance compared with traditional Gauss-Newton inversion (GNI) method. For measured data, the result of SDL-EIT is reasonable compared with computed tomography (CT) scan image. SIGNIFICANCE Using SDL-EIT, prior information can be easily integrated through the specifically designed training data set, and the image reconstruction process can be accelerated. The algorithm is effective in inverting measured thoracic data. It is a potential algorithm for human thorax imaging.
Collapse
|
30
|
Noninvasive, simultaneous, and continuous measurements of stroke volume and tidal volume using EIT: feasibility study of animal experiments. Sci Rep 2020; 10:11242. [PMID: 32647206 PMCID: PMC7347894 DOI: 10.1038/s41598-020-68139-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2020] [Accepted: 06/18/2020] [Indexed: 12/01/2022] Open
Abstract
Currently, there is no noninvasive method available for simultaneous measurements of tidal volume and stroke volume. Electrical impedance tomography (EIT) has been used for regional lung ventilation imaging. Cardiac EIT imaging, however, has not been successful due to the technical difficulty in extracting weak cardiogenic components. Instead of regional imaging, in this paper, we use the EIT technique to simultaneously measure two global variables of tidal volume and stroke volume. Time-varying patterns of boundary voltage data originating from lung ventilation and cardiac blood flow were extracted from measured boundary voltage data using the principal component analysis (PCA) and independent component analysis (ICA). The source consistency theory was adopted to separately synthesize time-series of boundary voltage data associated with lung ventilation and cardiac blood flow. The respiratory volume signal (RVS) and cardiac volume signal (CVS) were extracted from reconstructed time-difference EIT images of lung ventilation and cardiac blood flow, respectively. After calibrating the volume signals using the mechanical ventilator and the invasive transpulmonary thermodilution (TPTD) method, tidal volume and stroke volume were computed as valley-to-peak values of the RVS and CVS, respectively. The difference in the tidal volume data between EIT and mechanical ventilator was within ± 20 ml from six pigs. The difference in the stroke volume data between EIT and TPTD was within ± 4.7 ml from the same animals. The results show the feasibility of the proposed method as a new noninvasive cardiopulmonary monitoring tool for simultaneous continuous measurements of stroke volume and tidal volume that are two most important vital signs.
Collapse
|
31
|
Hopkins SR. Ventilation/Perfusion Relationships and Gas Exchange: Measurement Approaches. Compr Physiol 2020; 10:1155-1205. [PMID: 32941684 DOI: 10.1002/cphy.c180042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Ventilation-perfusion ( V ˙ A / Q ˙ ) matching, the regional matching of the flow of fresh gas to flow of deoxygenated capillary blood, is the most important mechanism affecting the efficiency of pulmonary gas exchange. This article discusses the measurement of V ˙ A / Q ˙ matching with three broad classes of techniques: (i) those based in gas exchange, such as the multiple inert gas elimination technique (MIGET); (ii) those derived from imaging techniques such as single-photon emission computed tomography (SPECT), positron emission tomography (PET), magnetic resonance imaging (MRI), computed tomography (CT), and electrical impedance tomography (EIT); and (iii) fluorescent and radiolabeled microspheres. The focus is on the physiological basis of these techniques that provide quantitative information for research purposes rather than qualitative measurements that are used clinically. The fundamental equations of pulmonary gas exchange are first reviewed to lay the foundation for the gas exchange techniques and some of the imaging applications. The physiological considerations for each of the techniques along with advantages and disadvantages are briefly discussed. © 2020 American Physiological Society. Compr Physiol 10:1155-1205, 2020.
Collapse
Affiliation(s)
- Susan R Hopkins
- Departments of Medicine and Radiology, University of California, San Diego, California, USA
| |
Collapse
|
32
|
Kao TJ, Amm B, Ashe J, Davenport D. Pulmonary Ventilation and Pulsatile Perfusion Imaging on Premature Neonates using Simultaneous Multi-Source EIT. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:1444-1447. [PMID: 33018262 DOI: 10.1109/embc44109.2020.9176446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
We applied our Simultaneous Multi-Source Electrical Impedance Tomography (SMS-EIT) system to detect pulmonary ventilation and pulsatile perfusion on 5 preterm newborns with respiratory distress syndrome under the nasal continuous positive airway pressure (CPAP) treatment. The results show that derived impedance changes have a potential for clinical application to evaluate effects in spontaneously breathing preterm infants with and without CPAP.
Collapse
|
33
|
Abdelwahab A, Shishvan OR, Saulnier GJ. Performance of an Adaptive Current Source for EIT Driving Loads through a Shielded Coaxial Cable. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:1448-1451. [PMID: 33018263 PMCID: PMC7671172 DOI: 10.1109/embc44109.2020.9175910] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In Electrical Impedance Tomography (EIT) the coaxial cables used to connect the electrodes to the electronics have long been a concern due to their impact on system performance. Driving the shield of the cable is useful, since it mitigates the shunt capacitance. However, this approach introduces complexity and, sometimes, stability issues. Using "active electrodes", i.e. placing the front end of the electronics at the electrode end of the cables, is also helpful but can introduce packaging and hygiene problems. In this paper, a new type of high-precision current source is described and its performance is studied when driving loads through a coaxial cable. This new current source adjusts its current output to compensate for current lost in any shunt impedance to ground, including the shunt losses in the cable. Experimental results for frequencies up to 1 MHz are provided, comparing performance with resistive and complex loads connected without a cable, with 1 m of RG-174 coaxial cable with a driven shield, and 1 m of RG-174 coaxial cable with a grounded shield. The results for all 3 cases are similar, demonstrating that the source can provide satisfactory performance with a grounded-shield cable.
Collapse
|
34
|
Borges JB, Cronin JN, Crockett DC, Hedenstierna G, Larsson A, Formenti F. Real-time effects of PEEP and tidal volume on regional ventilation and perfusion in experimental lung injury. Intensive Care Med Exp 2020; 8:10. [PMID: 32086632 PMCID: PMC7035410 DOI: 10.1186/s40635-020-0298-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2019] [Accepted: 01/30/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Real-time bedside information on regional ventilation and perfusion during mechanical ventilation (MV) may help to elucidate the physiological and pathophysiological effects of MV settings in healthy and injured lungs. We aimed to study the effects of positive end-expiratory pressure (PEEP) and tidal volume (VT) on the distributions of regional ventilation and perfusion by electrical impedance tomography (EIT) in healthy and injured lungs. METHODS One-hit acute lung injury model was established in 6 piglets by repeated lung lavages (injured group). Four ventilated piglets served as the control group. A randomized sequence of any possible combination of three VT (7, 10, and 15 ml/kg) and four levels of PEEP (5, 8, 10, and 12 cmH2O) was performed in all animals. Ventilation and perfusion distributions were computed by EIT within three regions-of-interest (ROIs): nondependent, middle, dependent. A mixed design with one between-subjects factor (group: intervention or control), and two within-subjects factors (PEEP and VT) was used, with a three-way mixed analysis of variance (ANOVA). RESULTS Two-way interactions between PEEP and group, and VT and group, were observed for the dependent ROI (p = 0.035 and 0.012, respectively), indicating that the increase in the dependent ROI ventilation was greater at higher PEEP and VT in the injured group than in the control group. A two-way interaction between PEEP and VT was observed for perfusion distribution in each ROI: nondependent (p = 0.030), middle (p = 0.006), and dependent (p = 0.001); no interaction was observed between injured and control groups. CONCLUSIONS Large PEEP and VT levels were associated with greater pulmonary ventilation of the dependent lung region in experimental lung injury, whereas they affected pulmonary perfusion of all lung regions both in the control and in the experimental lung injury groups.
Collapse
Affiliation(s)
- João Batista Borges
- Centre for Human and Applied Physiological Sciences, King's College London, London, UK.
| | - John N Cronin
- Centre for Human and Applied Physiological Sciences, King's College London, London, UK
| | | | - Göran Hedenstierna
- Hedenstierna Laboratory, Department of Medical Sciences, Uppsala University, Uppsala, Sweden
| | - Anders Larsson
- Hedenstierna Laboratory, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Federico Formenti
- Centre for Human and Applied Physiological Sciences, King's College London, London, UK. .,Nuffield Division of Anaesthetics, University of Oxford, Oxford, UK.
| |
Collapse
|
35
|
Braun F, Proença M, Wendler A, Solà J, Lemay M, Thiran JP, Weiler N, Frerichs I, Becher T. Noninvasive measurement of stroke volume changes in critically ill patients by means of electrical impedance tomography. J Clin Monit Comput 2019; 34:903-911. [PMID: 31624996 DOI: 10.1007/s10877-019-00402-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 10/10/2019] [Indexed: 10/25/2022]
Abstract
Previous animal experiments have suggested that electrical impedance tomography (EIT) has the ability to noninvasively track changes in cardiac stroke volume (SV). The present study intended to reproduce these findings in patients during a fluid challenge. In a prospective observational study including critically ill patients on mechanical ventilation, SV was estimated via ECG-gated EIT before and after a fluid challenge and compared to transpulmonary thermodilution reference measurements. Relative changes in EIT-derived cardiosynchronous impedance changes in the heart ([Formula: see text]) and lung region ([Formula: see text]) were compared to changes in reference SV by assessing the concordance rate (CR) and Pearson's correlation coefficient (R). We compared 39 measurements of 20 patients. [Formula: see text] did not show to be a reliable estimate for tracking changes of SV (CR = 52.6% and R = 0.13 with P = 0.44). In contrast, [Formula: see text] showed an acceptable trending performance (CR = 94.4% and R = 0.72 with P < 0.0001). Our results indicate that ECG-gated EIT measurements of [Formula: see text] are able to noninvasively monitor changes in SV during a fluid challenge in critically ill patients. However, this was not possible using [Formula: see text]. The present approach is limited by the influences induced by ventilation, posture or changes in electrode-skin contact and requires further validation.
Collapse
Affiliation(s)
- Fabian Braun
- Centre Suisse d'Electronique et de Microtechnique (CSEM SA), Rue Jaquet-Droz 1, 2002, Neuchâtel, Switzerland. .,Signal Processing Laboratory LTS5, Swiss Federal Institute of Technology in Lausanne (EPFL), Lausanne, Switzerland.
| | - Martin Proença
- Centre Suisse d'Electronique et de Microtechnique (CSEM SA), Rue Jaquet-Droz 1, 2002, Neuchâtel, Switzerland.,Signal Processing Laboratory LTS5, Swiss Federal Institute of Technology in Lausanne (EPFL), Lausanne, Switzerland
| | - Anna Wendler
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Josep Solà
- Centre Suisse d'Electronique et de Microtechnique (CSEM SA), Rue Jaquet-Droz 1, 2002, Neuchâtel, Switzerland
| | - Mathieu Lemay
- Centre Suisse d'Electronique et de Microtechnique (CSEM SA), Rue Jaquet-Droz 1, 2002, Neuchâtel, Switzerland
| | - Jean-Phillipe Thiran
- Signal Processing Laboratory LTS5, Swiss Federal Institute of Technology in Lausanne (EPFL), Lausanne, Switzerland.,Department of Radiology, University Hospital Center and University of Lausanne, Lausanne, Switzerland
| | - Norbert Weiler
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Tobias Becher
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| |
Collapse
|
36
|
Electrical Impedance Tomography for Cardio-Pulmonary Monitoring. J Clin Med 2019; 8:jcm8081176. [PMID: 31394721 PMCID: PMC6722958 DOI: 10.3390/jcm8081176] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 08/05/2019] [Accepted: 08/06/2019] [Indexed: 12/14/2022] Open
Abstract
Electrical impedance tomography (EIT) is a bedside monitoring tool that noninvasively visualizes local ventilation and arguably lung perfusion distribution. This article reviews and discusses both methodological and clinical aspects of thoracic EIT. Initially, investigators addressed the validation of EIT to measure regional ventilation. Current studies focus mainly on its clinical applications to quantify lung collapse, tidal recruitment, and lung overdistension to titrate positive end-expiratory pressure (PEEP) and tidal volume. In addition, EIT may help to detect pneumothorax. Recent studies evaluated EIT as a tool to measure regional lung perfusion. Indicator-free EIT measurements might be sufficient to continuously measure cardiac stroke volume. The use of a contrast agent such as saline might be required to assess regional lung perfusion. As a result, EIT-based monitoring of regional ventilation and lung perfusion may visualize local ventilation and perfusion matching, which can be helpful in the treatment of patients with acute respiratory distress syndrome (ARDS).
Collapse
|
37
|
Stowe S, Boyle A, Sage M, See W, Praud JP, Fortin-Pellerin É, Adler A. Comparison of bolus- and filtering-based EIT measures of lung perfusion in an animal model. Physiol Meas 2019; 40:054002. [PMID: 30965314 DOI: 10.1088/1361-6579/ab1794] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Two main functional imaging approaches have been used to measure regional lung perfusion using electrical impedance tomography (EIT): venous injection of a hypertonic saline contrast agent and imaging of its passage through the heart and lungs, and digital filtering of heart-frequency impedance changes over sequences of EIT images. This paper systematically compares filtering-based perfusion estimates and bolus injection methods to determine to which degree they are related. APPROACH EIT data was recorded on seven mechanically ventilated newborn lambs in which ventilation distribution was varied through changes in posture between prone, supine, left- and right-lateral positions. Perfusion images were calculated using frequency filtering and ensemble averaging during both ventilation and apnoea time segments for each posture to compare against contrast agent-based methods using Jaccard distance score. MAIN RESULTS Using bolus-based EIT measures of lung perfusion as the reference frequency filtering techniques performed better than ensemble averaging and both techniques performed equally well across apnoea and ventilation data segments. SIGNIFICANCE Our results indicate the potential for use of filtering-based EIT measures of heart-frequency activity as a non-invasive proxy for contrast agent injection-based measures of lung perfusion.
Collapse
Affiliation(s)
- Symon Stowe
- Systems and Computer Engineering, Carleton University, Ottawa, Canada. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | |
Collapse
|
38
|
Bluth T, Kiss T, Kircher M, Braune A, Bozsak C, Huhle R, Scharffenberg M, Herzog M, Roegner J, Herzog P, Vivona L, Millone M, Dössel O, Andreeff M, Koch T, Kotzerke J, Stender B, Gama de Abreu M. Measurement of relative lung perfusion with electrical impedance and positron emission tomography: an experimental comparative study in pigs. Br J Anaesth 2019; 123:246-254. [PMID: 31160064 DOI: 10.1016/j.bja.2019.04.056] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 04/08/2019] [Accepted: 04/09/2019] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) with indicator dilution may be clinically useful to measure relative lung perfusion, but there is limited information on the performance of this technique. METHODS Thirteen pigs (50-66 kg) were anaesthetised and mechanically ventilated. Sequential changes in ventilation were made: (i) right-lung ventilation with left-lung collapse, (ii) two-lung ventilation with optimised PEEP, (iii) two-lung ventilation with zero PEEP after saline lung lavage, (iv) two-lung ventilation with maximum PEEP (20/25 cm H2O to achieve peak airway pressure 45 cm H2O), and (v) two-lung ventilation under unilateral pulmonary artery occlusion. Relative lung perfusion was assessed with EIT and central venous injection of saline 3%, 5%, and 10% (10 ml) during breath holds. Relative perfusion was determined by positron emission tomography (PET) using 68Gallium-labelled microspheres. EIT and PET were compared in eight regions of equal ventro-dorsal height (right, left, ventral, mid-ventral, mid-dorsal, and dorsal), and directional changes in regional perfusion were determined. RESULTS Differences between methods were relatively small (95% of values differed by less than 8.7%, 8.9%, and 9.5% for saline 10%, 5%, and 3%, respectively). Compared with PET, EIT underestimated relative perfusion in dependent, and overestimated it in non-dependent, regions. EIT and PET detected the same direction of change in relative lung perfusion in 68.9-95.9% of measurements. CONCLUSIONS The agreement between EIT and PET for measuring and tracking changes of relative lung perfusion was satisfactory for clinical purposes. Indicator-based EIT may prove useful for measuring pulmonary perfusion at bedside.
Collapse
Affiliation(s)
- T Bluth
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - T Kiss
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - M Kircher
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - A Braune
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - C Bozsak
- Drägerwerk AG & Co. KGaA, Lübeck, Germany
| | - R Huhle
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - M Scharffenberg
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - M Herzog
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - J Roegner
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - P Herzog
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - L Vivona
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Naples, Italy
| | - M Millone
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; IRCCS AOU San Martino IST, Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, Genoa, Italy
| | - O Dössel
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - M Andreeff
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Dresden, Germany
| | - T Koch
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - J Kotzerke
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Dresden, Germany
| | - B Stender
- Drägerwerk AG & Co. KGaA, Lübeck, Germany
| | - M Gama de Abreu
- Pulmonary Engineering Group Dresden, Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.
| |
Collapse
|
39
|
de Castro Martins T, Sato AK, de Moura FS, de Camargo EDLB, Silva OL, Santos TBR, Zhao Z, Möeller K, Amato MBP, Mueller JL, Lima RG, de Sales Guerra Tsuzuki M. A Review of Electrical Impedance Tomography in Lung Applications: Theory and Algorithms for Absolute Images. ANNUAL REVIEWS IN CONTROL 2019; 48:442-471. [PMID: 31983885 PMCID: PMC6980523 DOI: 10.1016/j.arcontrol.2019.05.002] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Electrical Impedance Tomography (EIT) is under fast development, the present paper is a review of some procedures that are contributing to improve spatial resolution and material properties accuracy, admitivitty or impeditivity accuracy. A review of EIT medical applications is presented and they were classified into three broad categories: ARDS patients, obstructive lung diseases and perioperative patients. The use of absolute EIT image may enable the assessment of absolute lung volume, which may significantly improve the clinical acceptance of EIT. The Control Theory, the State Observers more specifically, have a developed theory that can be used for the design and operation of EIT devices. Electrode placement, current injection strategy and electrode electric potential measurements strategy should maximize the number of observable and controllable directions of the state vector space. A non-linear stochastic state observer, the Unscented Kalman Filter, is used directly for the reconstruction of absolute EIT images. Historically, difference images were explored first since they are more stable in the presence of modelling errors. Absolute images require more detailed models of contact impedance, stray capacitance and properly refined finite element mesh where the electric potential gradient is high. Parallelization of the forward program computation is necessary since the solution of the inverse problem often requires frequent solutions of the forward problem. Several reconstruction algorithms benefit by the Bayesian inverse problem approach and the concept of prior information. Anatomic and physiologic information are used to form the prior information. An already tested methodology is presented to build the prior probability density function using an ensemble of CT scans and in vivo impedance measurements. Eight absolute EIT image algorithms are presented.
Collapse
Affiliation(s)
| | - André Kubagawa Sato
- Computational Geometry Laboratory, Escola Politécnica da Universidade de São Paulo, Brazil
| | - Fernando Silva de Moura
- Universidade Federal do ABC, Center of Engineering, Modeling and Applied Social Sciences, Brazil
| | | | - Olavo Luppi Silva
- Universidade Federal do ABC, Center of Engineering, Modeling and Applied Social Sciences, Brazil
| | | | - Zhanqi Zhao
- Institute of Technical Medicine, Furtwangen University, Germany
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China
| | - Knut Möeller
- Institute of Technical Medicine, Furtwangen University, Germany
| | - Marcelo Brito Passos Amato
- Respiratory Intensive Care Unit, Pulmonary Division, Hospital das Clínicas, Universidade de São Paulo, Brazil
| | - Jennifer L Mueller
- Department of Mathematics, and School of Biomedical Engineering, Colorado State University, United States of America
| | - Raul Gonzalez Lima
- Department of Mechanical Engineering, Escola Politécnica da Universidade de São Paulo, Brazil
| | | |
Collapse
|
40
|
Sobota V, Müller M, Roubík K. Intravenous administration of normal saline may be misinterpreted as a change of end-expiratory lung volume when using electrical impedance tomography. Sci Rep 2019; 9:5775. [PMID: 30962469 PMCID: PMC6453964 DOI: 10.1038/s41598-019-42241-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Accepted: 03/26/2019] [Indexed: 11/30/2022] Open
Abstract
Electrical impedance tomography (EIT) is a noninvasive imaging modality that allows real-time monitoring of regional lung ventilation. The aim of the study is to investigate whether fast saline infusion causes changes in lung impedance that could affect the interpretation of EIT data. Eleven pigs were anaesthetized and mechanically ventilated. A bolus of 500 mL of normal saline was administered rapidly. Two PEEP steps were performed to allow quantification of the effect of normal saline on lung impedance. The mean change of end-expiratory lung impedance (EELI) caused by the saline bolus was equivalent to a virtual decrease of end-expiratory lung volume (EELV) by 227 (188–250) mL and decremental PEEP step of 4.40 (3.95–4.59) cmH2O (median and interquartile range). In contrast to the changes of PEEP, the administration of normal saline did not cause any significant differences in measured EELV, regional distribution of lung ventilation determined by EIT or in extravascular lung water and intrathoracic blood volume. In conclusion, EELI can be affected by the changes of EELV as well as by the administration of normal saline. These two phenomena can be distinguished by analysis of regional distribution of lung ventilation.
Collapse
Affiliation(s)
- Vladimír Sobota
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic. .,Department of Physiology, Maastricht University, Maastricht, The Netherlands.
| | - Martin Müller
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.,Department of Anaesthesiology and Intensive Care, First Faculty of Medicine, Charles University and Thomayer Hospital, Prague, Czech Republic
| | - Karel Roubík
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic
| |
Collapse
|
41
|
Vasques F, Sanderson B, Barrett NA, Camporota L. Monitoring of regional lung ventilation using electrical impedance tomography. Minerva Anestesiol 2019; 85:1231-1241. [PMID: 30945516 DOI: 10.23736/s0375-9393.19.13477-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Among recent lung imaging techniques and devices, electrical impedance tomography (EIT) can provide dynamic information on the distribution regional lung ventilation. EIT images possess a high temporal and functional resolution allowing the visualization of dynamic physiological and pathological changes on a breath-by-breath basis. EIT detects changes in electric impedance (i.e., changes in gas/fluid ratio) and describes them in real time, both visually through images and waveforms, and numerically, allowing the clinician to monitor disease evolution and response to treatment. The use of EIT in clinical practice is supported by several studies demonstrating a good correlation between impedance tomography data and other validated methods of measuring lung volume. In this review, we will provide an overview on the rationale, basic functioning and most common applications of EIT in the management of mechanically ventilated patients.
Collapse
Affiliation(s)
- Francesco Vasques
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, King's Health Partners, London, UK.,Division of Centre of Human Applied Physiological Sciences, King's College London, London, UK
| | - Barnaby Sanderson
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, King's Health Partners, London, UK.,Division of Centre of Human Applied Physiological Sciences, King's College London, London, UK
| | - Nicholas A Barrett
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, King's Health Partners, London, UK.,Division of Centre of Human Applied Physiological Sciences, King's College London, London, UK
| | - Luigi Camporota
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, King's Health Partners, London, UK - .,Division of Centre of Human Applied Physiological Sciences, King's College London, London, UK
| |
Collapse
|
42
|
Reinius H, Borges JB, Engström J, Ahlgren O, Lennmyr F, Larsson A, Fredén F. Optimal PEEP during one-lung ventilation with capnothorax: An experimental study. Acta Anaesthesiol Scand 2019; 63:222-231. [PMID: 30132806 DOI: 10.1111/aas.13247] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Revised: 07/12/2018] [Accepted: 07/24/2018] [Indexed: 01/01/2023]
Abstract
BACKGROUND One-lung ventilation (OLV) with induced capnothorax carries the risk of severely impaired ventilation and circulation. Optimal PEEP may mitigate the physiological perturbations during these conditions. METHODS Right-sided OLV with capnothorax (16 cm H2 O) on the left side was initiated in eight anesthetized, muscle-relaxed piglets. A recruitment maneuver and a decremental PEEP titration from PEEP 20 cm H2 O to zero end-expiratory pressure (ZEEP) was performed. Regional ventilation and perfusion were studied with electrical impedance tomography and computer tomography of the chest was used. End-expiratory lung volume and hemodynamics were recorded and. RESULTS PaO2 peaked at PEEP 12 cm H2 O (49 ± 14 kPa) and decreased to 11 ± 5 kPa at ZEEP (P < 0.001). PaCO2 was 9.5 ± 1.3 kPa at 20 cm H2 O PEEP and did not change when PEEP step-wise was reduced to 12 cm H2 O PaCO2. At lower PEEP, PaCO2 increased markedly. The ventilatory driving pressure was lowest at PEEP 14 cm H2 O (19.6 ± 5.8 cm H2 O) and increased to 38.3 ± 6.1 cm H2 O at ZEEP (P < 0.001). When reducing PEEP below 12-14 cm H2 O ventilation shifted from the dependent to the nondependent regions of the ventilated lung (P = 0.003), and perfusion shifted from the ventilated to the nonventilated lung (P = 0.02). CONCLUSION Optimal PEEP was 12-18 cm H2 O and probably relates to capnothorax insufflation pressure. With suboptimal PEEP, ventilation/perfusion mismatch in the ventilated lung and redistribution of blood flow to the nonventilated lung occurred.
Collapse
Affiliation(s)
- Henrik Reinius
- Department of Surgical Sciences; Hedenstierna laboratory; Section of Anesthesiology and Intensive Care; Uppsala University; Uppsala Sweden
| | - Joao Batista Borges
- Department of Surgical Sciences; Hedenstierna laboratory; Section of Anesthesiology and Intensive Care; Uppsala University; Uppsala Sweden
- Laboratório de Pneumologia LIM-09; Disciplina de Pneumologia; Heart Institute (Incor) Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo; São Paulo Brazil
| | - Joakim Engström
- Department of Surgical Sciences; Hedenstierna laboratory; Section of Anesthesiology and Intensive Care; Uppsala University; Uppsala Sweden
| | - Oskar Ahlgren
- Department of Surgical Sciences; Hedenstierna laboratory; Section of Anesthesiology and Intensive Care; Uppsala University; Uppsala Sweden
| | - Fredrik Lennmyr
- Department of Surgical Sciences; Hedenstierna laboratory; Section of Anesthesiology and Intensive Care; Uppsala University; Uppsala Sweden
- Department of Cardiothoracic Anesthesia; Uppsala University Hospital; Uppsala Sweden
| | - Anders Larsson
- Department of Surgical Sciences; Hedenstierna laboratory; Section of Anesthesiology and Intensive Care; Uppsala University; Uppsala Sweden
| | - Filip Fredén
- Department of Surgical Sciences; Hedenstierna laboratory; Section of Anesthesiology and Intensive Care; Uppsala University; Uppsala Sweden
| |
Collapse
|
43
|
Tingay DG, Waldmann AD, Frerichs I, Ranganathan S, Adler A. Electrical Impedance Tomography Can Identify Ventilation and Perfusion Defects: A Neonatal Case. Am J Respir Crit Care Med 2019; 199:384-386. [DOI: 10.1164/rccm.201808-1551le] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Affiliation(s)
- David G. Tingay
- Murdoch Children’s Research InstituteParkville, Victoria, Australia
- The Royal Children’s HospitalParkville, Victoria, Australia
- University of MelbourneMelbourne, Victoria, Australia
| | | | - Inéz Frerichs
- University Medical Centre Schleswig-HolsteinKiel, Germanyand
| | - Sarath Ranganathan
- Murdoch Children’s Research InstituteParkville, Victoria, Australia
- The Royal Children’s HospitalParkville, Victoria, Australia
- University of MelbourneMelbourne, Victoria, Australia
| | - Andy Adler
- Systems and Computer EngineeringCarleton University, Ottawa, Ontario, Canada
| |
Collapse
|
44
|
Wei Z, Liu D, Chen X. Dominant-Current Deep Learning Scheme for Electrical Impedance Tomography. IEEE Trans Biomed Eng 2019; 66:2546-2555. [PMID: 30629486 DOI: 10.1109/tbme.2019.2891676] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE Deep learning has recently been applied to electrical impedance tomography (EIT) imaging. Nevertheless, there are still many challenges that this approach has to face, e.g., targets with sharp corners or edges cannot be well recovered when using circular inclusion training data. This paper proposes an iterative-based inversion method and a convolutional neural network (CNN) based inversion method to recover some challenging inclusions such as triangular, rectangular, or lung shapes, where the CNN-based method uses only random circle or ellipse training data. METHODS First, the iterative method, i.e., bases-expansion subspace optimization method (BE-SOM), is proposed based on a concept of induced contrast current (ICC) with total variation regularization. Second, the theoretical analysis of BE-SOM and the physical concepts introduced there motivate us to propose a dominant-current deep learning scheme for EIT imaging, in which dominant parts of ICC are utilized to generate multi-channel inputs of CNN. RESULTS The proposed methods are tested with both numerical and experimental data, where several realistic phantoms including simulated pneumothorax and pleural effusion pathologies are also considered. CONCLUSIONS AND SIGNIFICANCE Significant performance improvements of the proposed methods are shown in reconstructing targets with sharp corners or edges. It is also demonstrated that the proposed methods are capable of fast, stable, and high-quality EIT imaging, which is promising in providing quantitative images for potential clinical applications.
Collapse
|
45
|
Zhang K, Li M, Yang F, Xu S, Abubakar A. Three-Dimensional Electrical Impedance Tomography With Multiplicative Regularization. IEEE Trans Biomed Eng 2019; 66:2470-2480. [PMID: 30605089 DOI: 10.1109/tbme.2018.2890410] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE The multiplicative regularization scheme is applied to three-dimensional electrical impedance tomography (EIT) image reconstruction problem to alleviate its ill-posedness. METHODS A cost functional is constructed by multiplying the data misfit functional with the regularization functional. The regularization functional is based on a weighted L2-norm with the edge-preserving characteristic. Gauss-Newton method is used to minimize the cost functional. A method based on the discrete exterior calculus (DEC) theory is introduced to formulate the discrete gradient and divergence operators related to the regularization on unstructured meshes. RESULTS Both numerical and experimental results show good reconstruction accuracy and anti-noise performance of the algorithm. The reconstruction results using human thoracic data show promising applications in thorax imaging. CONCLUSION The multiplicative regularization can be applied to EIT image reconstruction with promising applications in thorax imaging. SIGNIFICANCE In the multiplicative regularization scheme, there is no need to set an artificial regularization parameter in the cost functional. This helps to reduce the workload related to choosing a regularization parameter which may require expertise and many numerical experiments. The DEC-based method provides a systematic and rigorous way to formulate operators on unstructured meshes. This may help EIT image reconstructions using regularizations imposing structural or spatial constraints.
Collapse
|
46
|
Bachmann MC, Morais C, Bugedo G, Bruhn A, Morales A, Borges JB, Costa E, Retamal J. Electrical impedance tomography in acute respiratory distress syndrome. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2018; 22:263. [PMID: 30360753 PMCID: PMC6203288 DOI: 10.1186/s13054-018-2195-6] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Accepted: 09/14/2018] [Indexed: 12/29/2022]
Abstract
Acute respiratory distress syndrome (ARDS) is a clinical entity that acutely affects the lung parenchyma, and is characterized by diffuse alveolar damage and increased pulmonary vascular permeability. Currently, computed tomography (CT) is commonly used for classifying and prognosticating ARDS. However, performing this examination in critically ill patients is complex, due to the need to transfer these patients to the CT room. Fortunately, new technologies have been developed that allow the monitoring of patients at the bedside. Electrical impedance tomography (EIT) is a monitoring tool that allows one to evaluate at the bedside the distribution of pulmonary ventilation continuously, in real time, and which has proven to be useful in optimizing mechanical ventilation parameters in critically ill patients. Several clinical applications of EIT have been developed during the last years and the technique has been generating increasing interest among researchers. However, among clinicians, there is still a lack of knowledge regarding the technical principles of EIT and potential applications in ARDS patients. The aim of this review is to present the characteristics, technical concepts, and clinical applications of EIT, which may allow better monitoring of lung function during ARDS.
Collapse
Affiliation(s)
- M Consuelo Bachmann
- Departamento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile.,Acute Respiratory and Critical Illness Center (ARCI), Santiago, Chile
| | - Caio Morais
- Divisao de Pneumologia, Instituto do Coracao (Incor), Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, Brazil
| | - Guillermo Bugedo
- Departamento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile.,Acute Respiratory and Critical Illness Center (ARCI), Santiago, Chile
| | - Alejandro Bruhn
- Departamento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile.,Acute Respiratory and Critical Illness Center (ARCI), Santiago, Chile
| | - Arturo Morales
- Departamento Enfermedades Respiratorias, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - João B Borges
- Divisao de Pneumologia, Instituto do Coracao (Incor), Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, Brazil.,Hedenstierna Laboratory, Department of Surgical Sciences, Section of Anaesthesiology and Critical Care, Uppsala University, Uppsala, Sweden
| | - Eduardo Costa
- Divisao de Pneumologia, Instituto do Coracao (Incor), Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, Brazil
| | - Jaime Retamal
- Departamento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile. .,Acute Respiratory and Critical Illness Center (ARCI), Santiago, Chile.
| |
Collapse
|
47
|
Klassen C, Eckert CE, Wong J, Guyette JP, Harris JL, Thompson S, Wudel LJ, Ott HC. Ex Vivo Modeling of Perioperative Air Leaks in Porcine Lungs. IEEE Trans Biomed Eng 2018; 65:2827-2836. [PMID: 29993403 DOI: 10.1109/tbme.2018.2819625] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE A novel ex vivo model is described to advance the understanding of prolonged air leaks, one of the most common postoperative complications following thoracic resection procedures. METHODS As an alternative to in vivo testing, an ex vivo model simulating the various physiologic environments experienced by an isolated lung during the perioperative period was designed and built. Isolated porcine lungs were perfused and ventilated during open chest and closed chest simulations, mimicking intra and postoperative ventilation conditions. To assess and validate system capabilities, nine porcine lungs were tested by creating a standardized injury to create an approximately 250 cc/min air leak. Air leak rates, physiologic ventilation, and perfusion parameters were continuously monitored, while gas transfer analysis was performed on selected lungs. Segmental ventilation was monitored using electrical impedance tomography. RESULTS The evaluated lungs produced flow-volume and pressure-volume loops that approximated standard clinical representations under positive (mechanical) and negative (physiological) pressure ventilation modalities. Leak rate was averaged across the ventilation phases, and sharp increases in leak rate were observed between positive and negative pressure phases, suggesting that differences or changes in ventilation mechanics may strongly influence leak development. CONCLUSION The successful design and validation of a novel ex vivo lung model was achieved. Model output paralleled clinical observations. Pressure modality may also play a significant role in air leak severity. SIGNIFICANCE This work provides a foundation for future studies aimed at increasing the understanding of air leaks to better inform means of mitigating the risk of air leaks under clinically relevant conditions.
Collapse
|
48
|
Hentze B, Muders T, Luepschen H, Maripuu E, Hedenstierna G, Putensen C, Walter M, Leonhardt S. Regional lung ventilation and perfusion by electrical impedance tomography compared to single-photon emission computed tomography. Physiol Meas 2018; 39:065004. [PMID: 29794336 DOI: 10.1088/1361-6579/aac7ae] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Electrical impedance tomography (EIT) is a noninvasive imaging modality that allows real-time monitoring of regional lung ventilation ([Formula: see text]) in intensive care patients at bedside. However, for improved guidance of ventilation therapy it would be beneficial to obtain regional ventilation-to-perfusion ratio ([Formula: see text]) by EIT. APPROACH In order to further explore the feasibility, we first evaluate a model-based approach, based on semi-negative matrix factorization and a gamma-variate model, to extract regional lung perfusion ([Formula: see text]) from EIT measurements. Subsequently, a combined validation of both [Formula: see text] and [Formula: see text] measured by EIT against single-photon emission computed tomography (SPECT) is performed on data acquired as part of a porcine animal trial. Four pigs were ventilated at two different levels of positive end-expiratory pressure (PEEP 0 and 15 cm H2O, respectively) in randomized order. Repeated injections of an EIT contrast agent (NaCl 10%) and simultaneous SPECT measurements of [Formula: see text] (81mKr gas) and [Formula: see text] (99mTc-labeled albumin) were performed. MAIN RESULTS Both [Formula: see text] and [Formula: see text] from EIT and SPECT were compared by correlation analysis. Very strong (r 2 = 0.94 to 0.95) correlations were found for [Formula: see text] and [Formula: see text] in the dorsal-ventral direction at both PEEP levels. Moderate (r 2 = 0.36 to 0.46) and moderate to strong (r 2 = 0.61 to 0.82) correlations resulted for [Formula: see text] and [Formula: see text] in the right-left direction, respectively. SIGNIFICANCE The results of combined validation indicate that monitoring of [Formula: see text] and [Formula: see text] by EIT is possible. However, care should be taken when trying to quantify [Formula: see text] by EIT, as imaging artefacts and model bias may void necessary spatial matching.
Collapse
Affiliation(s)
- Benjamin Hentze
- Philips Chair for Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany. Department of Anaesthesiology and Intensive Care Medicine, University of Bonn, Sigmund-Freud-Str. 25, 53105 Bonn, Germany
| | | | | | | | | | | | | | | |
Collapse
|
49
|
Mueller JL, Muller P, Mellenthin M, Murthy R, Capps M, Alsaker M, Deterding R, Sagel SD, DeBoer E. Estimating regions of air trapping from electrical impedance tomography data. Physiol Meas 2018; 39:05NT01. [PMID: 29726838 PMCID: PMC6015736 DOI: 10.1088/1361-6579/aac295] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Electrical impedance tomography (EIT) has been shown to be a viable non-invasive, bedside imaging modality to monitor lung function. This paper introduces a method for identifying regions of air trapping from EIT data collected during tidal breathing and breath-holding maneuvers. APPROACH Ventilation-perfusion index maps are computed from dynamic EIT images. These maps are then used to identify regions of air trapping in the area of the lung as regions that are poorly ventilated but well perfused throughout the breathing and cardiac cycles. These EIT-identified regions are then compared with independently identified regions of low attenuation, or air trapping, on chest CT. Results of this method are demonstrated in two children with cystic fibrosis and on a healthy control subject. MAIN RESULTS In both CF children, the EIT-identified regions of air trapping matched the regions indicated from the chest CT. The EIT-based method is only validated with CT scans within 4 cm of the chest cross-section defined by the electrode plane. SIGNIFICANCE The results indicate the potential use of EIT-derived ventilation-perfusion index maps as a non-invasive method for identifying regions of air trapping.
Collapse
Affiliation(s)
- Jennifer L Mueller
- Department of Mathematics, Colorado State University, Fort Collins, CO, United States of America. School of Biomedical Engineering, Colorado State University, Fort Collins, CO, United States of America
| | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Muller PA, Mueller JL, Mellenthin M, Murthy R, Capps M, Wagner BD, Alsaker M, Deterding R, Sagel SD, Hoppe J. Evaluation of surrogate measures of pulmonary function derived from electrical impedance tomography data in children with cystic fibrosis. Physiol Meas 2018; 39:045008. [PMID: 29565263 DOI: 10.1088/1361-6579/aab8c4] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Lung function monitoring by spirometry plays a critical role in the clinical care of pediatric cystic fibrosis (CF) patients, but many young children are unable to perform spirometry, and the outputs are often normal even in the presence of lung disease. Measures derived from electrical impedance tomography (EIT) images were studied for their utility as potential surrogates for spirometry in CF patients and to assess response to intravenous antibiotic treatment for acute pulmonary exacerbations (PEx) in a subset of patients. APPROACH EIT data were collected on 35 subjects (21 with CF, 14 healthy controls, 8 CF patients pre- and post-treatment for an acute PEx) ages 2 to 20 years during tidal breathing and also concurrently with spirometry on subjects over age 8. EIT-derived measures of FEV1, FVC, and FEV1/FVC were computed globally and regionally from dynamic EIT images. MAIN RESULTS Global EIT-derived FEV1/FVC showed good correlation with spirometry FEV1/FVC values (r = 0.54, p = 0.01), and were able to distinguish between the groups (p = 0.01). Lung heterogeneity was assessed through the spatial coefficient of variation (CV) of EIT difference images between key time points, and the CVs for EIT-derived FEV1 and FVC showed significant correlation with the CV for tidal breathing (r = 0.47, p = 0.01 and r = 0.50, p = 0.01, respectively). Global EIT-derived FEV1/FVC was better able to distinguish between groups than spirometry FEV1 (F-values 776.5 and 146.3, respectively, p < 0.01.) The same held true for the CVs for EIT-derived FEV1, FVC, and tidal breathing (F-values 215.93, 193.89, 204.57, respectively, p < 0.01). SIGNIFICANCE The strong correlation between the CVs for tidal breathing, FEV1, and FVC, and the statistically significant ability of CV for tidal breathing to distinguish between healthy subjects and CF patients, and between the studied CF disease states suggests that the CV may be useful for measuring the extent and severity of structural lung disease.
Collapse
Affiliation(s)
- Peter A Muller
- Department of Mathematics & Statistics, Villanova University, PA, United States of America. was at Department of Mathematics, Colorado State University, CO, United States of America
| | | | | | | | | | | | | | | | | | | |
Collapse
|