Image-Based Finite Element Modeling Approach for Characterizing In Vivo Mechanical Properties of Human Arteries. J Funct Biomater 2022; 13:jfb13030147. [PMID: 36135582 PMCID: PMC9505727 DOI: 10.3390/jfb13030147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 09/07/2022] [Accepted: 09/07/2022] [Indexed: 11/17/2022] Open
Abstract
Mechanical properties of the arterial walls could provide meaningful information for the diagnosis, management and treatment of cardiovascular diseases. Classically, various experimental approaches were conducted on dissected arterial tissues to obtain their stress-stretch relationship, which has limited value clinically. Therefore, there is a pressing need to obtain biomechanical behaviors of these vascular tissues in vivo for personalized treatment. This paper reviews the methods to quantify arterial mechanical properties in vivo. Among these methods, we emphasize a novel approach using image-based finite element models to iteratively determine the material properties of the arterial tissues. This approach has been successfully applied to arterial walls in various vascular beds. The mechanical properties obtained from the in vivo approach were compared to those from ex vivo experimental studies to investigate whether any discrepancy in material properties exists for both approaches. Arterial tissue stiffness values from in vivo studies generally were in the same magnitude as those from ex vivo studies, but with lower average values. Some methodological issues, including solution uniqueness and robustness; method validation; and model assumptions and limitations were discussed. Clinical applications of this approach were also addressed to highlight their potential in translation from research tools to cardiovascular disease management.
Collapse
|
2
|
Bracamonte JH, Wilson JS, Soares JS. Quantification of the heterogeneous effect of static and dynamic perivascular structures on patient-specific local aortic wall mechanics using inverse finite element modeling and DENSE MRI. J Biomech 2022; 138:111119. [PMID: 35576631 PMCID: PMC9536506 DOI: 10.1016/j.jbiomech.2022.111119] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 04/28/2022] [Accepted: 04/29/2022] [Indexed: 11/30/2022]
Abstract
Recent studies have highlighted the relevance of perivascular interactions on aortic wall mechanics. Most of the approaches assume static perivascular structures; however, the beating heart dynamically displaces the neighboring aorta. We develop a model to account for the effect of periaortic interactions due to static and dynamic structures by prescribing a moving elastic foundation boundary condition (EFBC) embedded into an inverse finite element algorithm using in vivo displacements from 2D displacement encoding with stimulated echoes (DENSE) MRI as target data. We applied this method at three different locations of interest, the distal aortic arch (DAA), descending thoracic aorta (DTA), and infrarenal abdominal aorta (IAA) for a total of 27 cases in healthy humans. The model reproduces the target diastole-to-systole deformation and bulk displacement of the aortic wall with median displacement errors below 0.5mm. The EFBC showed good agreement with the location of anatomical features and was consistent among individuals of similar characteristics. Results show that an energy source acting on the adventitia is required to reproduce the displacements measured at the vicinity of the heart, but not at the abdomen. The average adventitial load as a percentage of the luminal pulse-pressure was found to increase with age and to decrease along the descending aorta, from 61% at the DAA to 37% at the DTA, and 30% at the IAA. This approach offers a patient-specific method to estimate in vivo adventitial loads and aortic wall stiffness, which can bring a better understanding of normal and pathological in vivo aortic function.
Collapse
Affiliation(s)
- Johane H Bracamonte
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, Richmond, VA 23284, United States.
| | - John S Wilson
- Department of Biomedical Engineering & Pauley Heart Center, Virginia Commonwealth University, 601 West Main Street, Richmond, VA 23284, United States.
| | - Joao S Soares
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, Richmond, VA 23284, United States.
| |
Collapse
|
3
|
Bracamonte JH, Saunders SK, Wilson JS, Truong UT, Soares JS. Patient-Specific Inverse Modeling of In Vivo Cardiovascular Mechanics with Medical Image-Derived Kinematics as Input Data: Concepts, Methods, and Applications. APPLIED SCIENCES-BASEL 2022; 12:3954. [PMID: 36911244 PMCID: PMC10004130 DOI: 10.3390/app12083954] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Inverse modeling approaches in cardiovascular medicine are a collection of methodologies that can provide non-invasive patient-specific estimations of tissue properties, mechanical loads, and other mechanics-based risk factors using medical imaging as inputs. Its incorporation into clinical practice has the potential to improve diagnosis and treatment planning with low associated risks and costs. These methods have become available for medical applications mainly due to the continuing development of image-based kinematic techniques, the maturity of the associated theories describing cardiovascular function, and recent progress in computer science, modeling, and simulation engineering. Inverse method applications are multidisciplinary, requiring tailored solutions to the available clinical data, pathology of interest, and available computational resources. Herein, we review biomechanical modeling and simulation principles, methods of solving inverse problems, and techniques for image-based kinematic analysis. In the final section, the major advances in inverse modeling of human cardiovascular mechanics since its early development in the early 2000s are reviewed with emphasis on method-specific descriptions, results, and conclusions. We draw selected studies on healthy and diseased hearts, aortas, and pulmonary arteries achieved through the incorporation of tissue mechanics, hemodynamics, and fluid-structure interaction methods paired with patient-specific data acquired with medical imaging in inverse modeling approaches.
Collapse
Affiliation(s)
- Johane H. Bracamonte
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
| | - Sarah K. Saunders
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
| | - John S. Wilson
- Department of Biomedical Engineering and Pauley Heart Center, Virginia Commonwealth University, Richmond, VA 23219, USA
| | - Uyen T. Truong
- Department of Pediatrics, School of Medicine, Children’s Hospital of Richmond at Virginia Commonwealth University, Richmond, VA 23219, USA
| | - Joao S. Soares
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
- Correspondence:
| |
Collapse
|
4
|
Bracamonte JH, Wilson JS, Soares JS. Assessing Patient-Specific Mechanical Properties of Aortic Wall and Peri-Aortic Structures From In Vivo DENSE Magnetic Resonance Imaging Using an Inverse Finite Element Method and Elastic Foundation Boundary Conditions. J Biomech Eng 2020; 142:121011. [PMID: 32632452 DOI: 10.1115/1.4047721] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Indexed: 11/08/2022]
Abstract
The establishment of in vivo, noninvasive patient-specific, and regionally resolved techniques to quantify aortic properties is key to improving clinical risk assessment and scientific understanding of vascular growth and remodeling. A promising and novel technique to reach this goal is an inverse finite element method (FEM) approach that utilizes magnetic resonance imaging (MRI)-derived displacement fields from displacement encoding with stimulated echoes (DENSE). Previous studies using DENSE MRI suggested that the infrarenal abdominal aorta (IAA) deforms heterogeneously during the cardiac cycle. We hypothesize that this heterogeneity is driven in healthy aortas by regional adventitial tethering and interaction with perivascular tissues, which can be modeled with elastic foundation boundary conditions (EFBCs) using a collection of radially oriented springs with varying stiffness with circumferential distribution. Nine healthy IAAs were modeled using previously acquired patient-specific imaging and displacement fields from steady-state free procession (SSFP) and DENSE MRI, followed by assessment of aortic wall properties and heterogeneous EFBC parameters using inverse FEM. In contrast to traction-free boundary condition, prescription of EFBC reduced the nodal displacement error by 60% and reproduced the DENSE-derived heterogeneous strain distribution. Estimated aortic wall properties were in reasonable agreement with previously reported experimental biaxial testing data. The distribution of normalized EFBC stiffness was consistent among all patients and spatially correlated to standard peri-aortic anatomical features, suggesting that EFBC could be generalized for human adults with normal anatomy. This approach is computationally inexpensive, making it ideal for clinical research and future incorporation into cardiovascular fluid-structure analyses.
Collapse
Affiliation(s)
- Johane H Bracamonte
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, Richmond, VA 23284
| | - John S Wilson
- Department of Biomedical Engineering and Pauley Heart Center, Virginia Commonwealth University, 601 West Main Street, Richmond, VA 23284
| | - Joao S Soares
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, Richmond, VA 23284
| |
Collapse
|
5
|
Deciphering ascending thoracic aortic aneurysm hemodynamics in relation to biomechanical properties. Med Eng Phys 2020; 82:119-129. [DOI: 10.1016/j.medengphy.2020.07.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 06/19/2020] [Accepted: 07/09/2020] [Indexed: 12/20/2022]
|
6
|
Trabelsi O, Duprey A, Favre JP, Avril S. Predictive Models with Patient Specific Material Properties for the Biomechanical Behavior of Ascending Thoracic Aneurysms. Ann Biomed Eng 2015; 44:84-98. [DOI: 10.1007/s10439-015-1374-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Accepted: 06/24/2015] [Indexed: 02/07/2023]
|
7
|
Perrin D, Badel P, Orgéas L, Geindreau C, Dumenil A, Albertini JN, Avril S. Patient-specific numerical simulation of stent-graft deployment: Validation on three clinical cases. J Biomech 2015; 48:1868-75. [PMID: 25979382 DOI: 10.1016/j.jbiomech.2015.04.031] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Revised: 02/25/2015] [Accepted: 04/23/2015] [Indexed: 11/17/2022]
Abstract
Endovascular repair of abdominal aortic aneurysms faces some adverse outcomes, such as kinks or endoleaks related to incomplete stent apposition, which are difficult to predict and which restrain its use although it is less invasive than open surgery. Finite element simulations could help to predict and anticipate possible complications biomechanically induced, thus enhancing practitioners' stent-graft sizing and surgery planning, and giving indications on patient eligibility to endovascular repair. The purpose of this work is therefore to develop a new numerical methodology to predict stent-graft final deployed shapes after surgery. The simulation process was applied on three clinical cases, using preoperative scans to generate patient-specific vessel models. The marketed devices deployed during the surgery, consisting of a main body and one or more iliac limbs or extensions, were modeled and their deployment inside the corresponding patient aneurysm was simulated. The numerical results were compared to the actual deployed geometry of the stent-grafts after surgery that was extracted from postoperative scans. We observed relevant matching between simulated and actual deployed stent-graft geometries, especially for proximal and distal stents outside the aneurysm sac which are particularly important for practitioners. Stent locations along the vessel centerlines in the three simulations were always within a few millimeters to actual stents locations. This good agreement between numerical results and clinical cases makes finite element simulation very promising for preoperative planning of endovascular repair.
Collapse
Affiliation(s)
- David Perrin
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, CNRS: UMR5307, LGF, F-42023 Saint-Etienne, France; CNRS, 3SR Lab, F-38000 Grenoble, France; Université Grenoble Alpes, 3SR Lab, F-38000 Grenoble, France
| | - Pierre Badel
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, CNRS: UMR5307, LGF, F-42023 Saint-Etienne, France
| | - Laurent Orgéas
- CNRS, 3SR Lab, F-38000 Grenoble, France; Université Grenoble Alpes, 3SR Lab, F-38000 Grenoble, France
| | - Christian Geindreau
- CNRS, 3SR Lab, F-38000 Grenoble, France; Université Grenoble Alpes, 3SR Lab, F-38000 Grenoble, France
| | - Aurélien Dumenil
- INSERM, U1099, F-35000 Rennes, France; Université de Rennes 1, LTSI, F-35000 Rennes, France; Therenva, F-35000 Rennes, France
| | - Jean-Noël Albertini
- CHU Hôpital Nord Saint-Etienne, Department of CardioVascular Surgery, Saint-Etienne F-42055, France; Université Jean Monnet, GRT EA 3065, Saint-Etienne F-42023, France
| | - Stéphane Avril
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, CNRS: UMR5307, LGF, F-42023 Saint-Etienne, France.
| |
Collapse
|
8
|
Perrin D, Demanget N, Badel P, Avril S, Orgéas L, Geindreau C, Albertini JN. Deployment of stent grafts in curved aneurysmal arteries: toward a predictive numerical tool. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2015; 31:e02698. [PMID: 25399927 DOI: 10.1002/cnm.2698] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Revised: 10/16/2014] [Accepted: 11/10/2014] [Indexed: 06/04/2023]
Abstract
The mechanical behavior of aortic stent grafts plays an important role in the success of endovascular surgery for aneurysms. In this study, finite element analysis was carried out to simulate the expansion of five marketed stent graft iliac limbs and to evaluate quantitatively their mechanical performances. The deployment was modeled in a simplified manner according to the following steps: (i) stent graft crimping and insertion in the delivery sheath, (ii) removal of the sheath and stent graft deployment in the aneurysm, and (iii) application of arterial pressure. In the most curved aneurysm and for some devices, a decrease of stent graft cross-sectional area up to 57% was found at the location of some kinks. Apposition defects onto the arterial wall were also clearly evidenced and quantified. Aneurysm inner curve presented significantly more apposition defects than outer curve. The feasibility of finite element analysis to simulate deployment of marketed stent grafts in curved aneurysm models was demonstrated. The study of the influence of aneurysm tortuosity on stent graft mechanical behavior shows that increasing vessel curvature leads to stent graft kinks and inadequate apposition against the arterial wall. Such simulation approach opens a very promising way toward surgical planning tools able to predict intra and/or post-operative short-term stent graft complications.
Collapse
Affiliation(s)
- David Perrin
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, CNRS:UMR5307, LGF, F-42023, Saint Etienne, France; CNRS, 3SR Lab, F-38000, Grenoble, France; Univ. Grenoble Alpes, 3SR Lab, F-38000, Grenoble, France
| | | | | | | | | | | | | |
Collapse
|
9
|
Franquet A, Avril S, Le Riche R, Badel P, Schneider F, Boissier C, Favre JP. Identification of the in vivo elastic properties of common carotid arteries from MRI: A study on subjects with and without atherosclerosis. J Mech Behav Biomed Mater 2013; 27:184-203. [DOI: 10.1016/j.jmbbm.2013.03.016] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2012] [Revised: 03/11/2013] [Accepted: 03/22/2013] [Indexed: 11/28/2022]
|