1
|
Plummer JW, Hussain R, Bdaiwi AS, Soderlund SA, Hoyos X, Lanier JM, Garrison WJ, Parra-Robles J, Willmering MM, Niedbalski P, Cleveland ZI, Walkup L. A decay-modeled compressed sensing reconstruction approach for non-Cartesian hyperpolarized 129Xe MRI. Magn Reson Med 2024; 92:1363-1375. [PMID: 38860514 PMCID: PMC11262966 DOI: 10.1002/mrm.30188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 04/15/2024] [Accepted: 05/18/2024] [Indexed: 06/12/2024]
Abstract
PURPOSE Hyperpolarized 129Xe MRI benefits from non-Cartesian acquisitions that sample k-space efficiently and rapidly. However, their reconstructions are complex and burdened by decay processes unique to hyperpolarized gas. Currently used gridded reconstructions are prone to artifacts caused by magnetization decay and are ill-suited for undersampling. We present a compressed sensing (CS) reconstruction approach that incorporates magnetization decay in the forward model, thereby producing images with increased sharpness and contrast, even in undersampled data. METHODS Radio-frequency, T1, andT 2 * $$ {\mathrm{T}}_2^{\ast } $$ decay processes were incorporated into the forward model and solved using iterative methods including CS. The decay-modeled reconstruction was validated in simulations and then tested in 2D/3D-spiral ventilation and 3D-radial gas-exchange MRI. Quantitative metrics including apparent-SNR and sharpness were compared between gridded, CS, and twofold undersampled CS reconstructions. Observations were validated in gas-exchange data collected from 15 healthy and 25 post-hematopoietic-stem-cell-transplant participants. RESULTS CS reconstructions in simulations yielded images with threefold increases in accuracy. CS increased sharpness and contrast for ventilation in vivo imaging and showed greater accuracy for undersampled acquisitions. CS improved gas-exchange imaging, particularly in the dissolved-phase where apparent-SNR improved, and structure was made discernable. Finally, CS showed repeatability in important global gas-exchange metrics including median dissolved-gas signal ratio and median angle between real/imaginary components. CONCLUSION A non-Cartesian CS reconstruction approach that incorporates hyperpolarized 129Xe decay processes is presented. This approach enables improved image sharpness, contrast, and overall image quality in addition to up-to threefold undersampling. This contribution benefits all hyperpolarized gas MRI through improved accuracy and decreased scan durations.
Collapse
Affiliation(s)
- J. W. Plummer
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States
- Center for Pulmonary Imaging Research, Department of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
| | - R. Hussain
- Center for Pulmonary Imaging Research, Department of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
| | - A. S. Bdaiwi
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States
- Center for Pulmonary Imaging Research, Department of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
| | - S. A. Soderlund
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States
- Center for Pulmonary Imaging Research, Department of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
| | - X. Hoyos
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States
- Center for Pulmonary Imaging Research, Department of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
| | - J. M. Lanier
- Department of Radiology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
| | - W. J. Garrison
- Center for Pulmonary Imaging Research, Department of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
| | - J. Parra-Robles
- Center for Pulmonary Imaging Research, Department of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
| | - M. M. Willmering
- Center for Pulmonary Imaging Research, Department of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
| | - P.J. Niedbalski
- Pulmonary, Critical Care and Sleep Medicine, Kansas University Medical Center, KS, United States
| | - Z. I. Cleveland
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States
- Center for Pulmonary Imaging Research, Department of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
- Department of Radiology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
- Department of Pediatrics, University of Cincinnati, Cincinnati, OH, United States
| | - L.L. Walkup
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States
- Center for Pulmonary Imaging Research, Department of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
- Department of Radiology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, United States
- Department of Pediatrics, University of Cincinnati, Cincinnati, OH, United States
| |
Collapse
|
2
|
Batarchuk V, Shepelytskyi Y, Grynko V, Kovacs AH, Hodgson A, Rodriguez K, Aldossary R, Talwar T, Hasselbrink C, Ruset IC, DeBoef B, Albert MS. Hyperpolarized Xenon-129 Chemical Exchange Saturation Transfer (HyperCEST) Molecular Imaging: Achievements and Future Challenges. Int J Mol Sci 2024; 25:1939. [PMID: 38339217 PMCID: PMC10856220 DOI: 10.3390/ijms25031939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Revised: 01/25/2024] [Accepted: 01/28/2024] [Indexed: 02/12/2024] Open
Abstract
Molecular magnetic resonance imaging (MRI) is an emerging field that is set to revolutionize our perspective of disease diagnosis, treatment efficacy monitoring, and precision medicine in full concordance with personalized medicine. A wide range of hyperpolarized (HP) 129Xe biosensors have been recently developed, demonstrating their potential applications in molecular settings, and achieving notable success within in vitro studies. The favorable nuclear magnetic resonance properties of 129Xe, coupled with its non-toxic nature, high solubility in biological tissues, and capacity to dissolve in blood and diffuse across membranes, highlight its superior role for applications in molecular MRI settings. The incorporation of reporters that combine signal enhancement from both hyperpolarized 129Xe and chemical exchange saturation transfer holds the potential to address the primary limitation of low sensitivity observed in conventional MRI. This review provides a summary of the various applications of HP 129Xe biosensors developed over the last decade, specifically highlighting their use in MRI. Moreover, this paper addresses the evolution of in vivo applications of HP 129Xe, discussing its potential transition into clinical settings.
Collapse
Affiliation(s)
- Viktoriia Batarchuk
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada; (V.B.)
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 6V4, Canada
| | - Yurii Shepelytskyi
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada; (V.B.)
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 6V4, Canada
| | - Vira Grynko
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 6V4, Canada
- Chemistry and Materials Science Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | - Antal Halen Kovacs
- Applied Life Science Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | - Aaron Hodgson
- Physics Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | - Karla Rodriguez
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada; (V.B.)
| | - Ruba Aldossary
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 6V4, Canada
| | - Tanu Talwar
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada; (V.B.)
| | - Carson Hasselbrink
- Chemistry & Biochemistry Department, California Polytechnic State University, San Luis Obispo, CA 93407-005, USA
| | | | - Brenton DeBoef
- Department of Chemistry, University of Rhode Island, Kingston, RI 02881, USA
| | - Mitchell S. Albert
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada; (V.B.)
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 6V4, Canada
- Faculty of Medical Sciences, Northern Ontario School of Medicine, Thunder Bay, ON P7B 5E1, Canada
| |
Collapse
|
3
|
Mikowska L, Grynko V, Shepelytskyi Y, Ruset IC, Deschamps J, Aalto H, Targosz-Korecka M, Balamore D, Harańczyk H, Albert MS. Revealing a Third Dissolved-Phase Xenon-129 Resonance in Blood Caused by Hemoglobin Glycation. Int J Mol Sci 2023; 24:11311. [PMID: 37511071 PMCID: PMC10380088 DOI: 10.3390/ijms241411311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Revised: 07/06/2023] [Accepted: 07/10/2023] [Indexed: 07/30/2023] Open
Abstract
Hyperpolarized (HP) xenon-129 (129Xe), when dissolved in blood, has two NMR resonances: one in red blood cells (RBC) and one in plasma. The impact of numerous blood components on these resonances, however, has not yet been investigated. This study evaluates the effects of elevated glucose levels on the chemical shift (CS) and T2* relaxation times of HP 129Xe dissolved in sterile citrated sheep blood for the first time. HP 129Xe was mixed with sheep blood samples premixed with a stock glucose solution using a liquid-gas exchange module. Magnetic resonance spectroscopy was performed on a 3T clinical MRI scanner using a custom-built quadrature dual-tuned 129Xe/1H coil. We observed an additional resonance for the RBCs (129Xe-RBC1) for the increased glucose levels. The CS of 129Xe-RBC1 and 129Xe-plasma peaks did not change with glucose levels, while the CS of 129Xe-RBC2 (original RBC resonance) increased linearly at a rate of 0.015 ± 0.002 ppm/mM with glucose level. 129Xe-RBC1 T2* values increased nonlinearly from 1.58 ± 0.24 ms to 2.67 ± 0.40 ms. As a result of the increased glucose levels in blood samples, the novel additional HP 129Xe dissolved phase resonance was observed in blood and attributed to the 129Xe bound to glycated hemoglobin (HbA1c).
Collapse
Affiliation(s)
- Lutosława Mikowska
- Faculty of Physics, Astronomy, and Applied Computer Science, Jagiellonian University, 30-348 Krakow, Poland
| | - Vira Grynko
- Chemistry and Material Science Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 7A5, Canada
| | - Yurii Shepelytskyi
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 7A5, Canada
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | | | - Joseph Deschamps
- Applied Life Sciences Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | - Hannah Aalto
- Applied Life Sciences Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | - Marta Targosz-Korecka
- Faculty of Physics, Astronomy, and Applied Computer Science, Jagiellonian University, 30-348 Krakow, Poland
| | - Dilip Balamore
- Department of Engineering, Physics and Technology, Nassau Community College, New York, NY 11530, USA
| | - Hubert Harańczyk
- Faculty of Physics, Astronomy, and Applied Computer Science, Jagiellonian University, 30-348 Krakow, Poland
| | - Mitchell S Albert
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 7A5, Canada
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
- Faculty of Medical Sciences, Northern Ontario School of Medicine University, Thunder Bay, ON P3E 2C6, Canada
| |
Collapse
|
4
|
Chung SH, Huynh KM, Goralski JL, Chen Y, Yap PT, Ceppe AS, Powell MZ, Donaldson SH, Lee YZ. Feasibility of free-breathing 19 F MRI image acquisition to characterize ventilation defects in CF and healthy volunteers at wash-in. Magn Reson Med 2023; 90:79-89. [PMID: 36912481 PMCID: PMC10149612 DOI: 10.1002/mrm.29630] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 01/27/2023] [Accepted: 02/15/2023] [Indexed: 03/14/2023]
Abstract
PURPOSE To explore the feasibility of measuring ventilation defect percentage (VDP) using 19 F MRI during free-breathing wash-in of fluorinated gas mixture with postacquisition denoising and to compare these results with those obtained through traditional Cartesian breath-hold acquisitions. METHODS Eight adults with cystic fibrosis and 5 healthy volunteers completed a single MR session on a Siemens 3T Prisma. 1 H Ultrashort-TE MRI sequences were used for registration and masking, and ventilation images with 19 F MRI were obtained while the subjects breathed a normoxic mixture of 79% perfluoropropane and 21% oxygen (O2 ). 19 F MRI was performed during breath holds and while free breathing with one overlapping spiral scan at breath hold for VDP value comparison. The 19 F spiral data were denoised using a low-rank matrix recovery approach. RESULTS VDP measured using 19 F VIBE and 19 F spiral images were highly correlated (r = 0.84) at 10 wash-in breaths. Second-breath VDPs were also highly correlated (r = 0.88). Denoising greatly increased SNR (pre-denoising spiral SNR, 2.46 ± 0.21; post-denoising spiral SNR, 33.91 ± 6.12; and breath-hold SNR, 17.52 ± 2.08). CONCLUSION Free-breathing 19 F lung MRI VDP analysis was feasible and highly correlated with breath-hold measurements. Free-breathing methods are expected to increase patient comfort and extend ventilation MRI use to patients who are unable to perform breath holds, including younger subjects and those with more severe lung disease.
Collapse
Affiliation(s)
- Sang Hun Chung
- Department of Biomedical Engineering, University of North Carolina, Chapel Hill, USA
| | - Khoi Minh Huynh
- Department of Biomedical Engineering, University of North Carolina, Chapel Hill, USA
| | - Jennifer L. Goralski
- Division of Pulmonary and Critical Care Medicine, UNC-Chapel Hill
- Marsico Lung Institute/UNC Cystic Fibrosis Center, UNC-Chapel Hill
- Division of Pediatric Pulmonology, UNC-Chapel Hill
| | - Yong Chen
- Department of Radiology, Case Western Reserve University, Cleveland, USA
| | - Pew-Thian Yap
- Department of Radiology and Biomedical Research Imaging Center, UNC-Chapel Hill
| | - Agathe S. Ceppe
- Division of Pulmonary and Critical Care Medicine, UNC-Chapel Hill
- Marsico Lung Institute/UNC Cystic Fibrosis Center, UNC-Chapel Hill
| | | | - Scott H. Donaldson
- Division of Pulmonary and Critical Care Medicine, UNC-Chapel Hill
- Marsico Lung Institute/UNC Cystic Fibrosis Center, UNC-Chapel Hill
| | - Yueh Z. Lee
- Division of Pulmonary and Critical Care Medicine, UNC-Chapel Hill
- Department of Radiology and Biomedical Research Imaging Center, UNC-Chapel Hill
| |
Collapse
|
5
|
Karmali D, Sowho M, Bose S, Pearce J, Tejwani V, Diamant Z, Yarlagadda K, Ponce E, Eikelis N, Otvos T, Khan A, Lester M, Fouras A, Kirkness J, Siddharthan T. Functional imaging for assessing regional lung ventilation in preclinical and clinical research. Front Med (Lausanne) 2023; 10:1160292. [PMID: 37261124 PMCID: PMC10228734 DOI: 10.3389/fmed.2023.1160292] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 04/17/2023] [Indexed: 06/02/2023] Open
Abstract
Dynamic heterogeneity in lung ventilation is an important measure of pulmonary function and may be characteristic of early pulmonary disease. While standard indices like spirometry, body plethysmography, and blood gases have been utilized to assess lung function, they do not provide adequate information on regional ventilatory distribution nor function assessments of ventilation during the respiratory cycle. Emerging technologies such as xenon CT, volumetric CT, functional MRI and X-ray velocimetry can assess regional ventilation using non-invasive radiographic methods that may complement current methods of assessing lung function. As a supplement to current modalities of pulmonary function assessment, functional lung imaging has the potential to identify respiratory disease phenotypes with distinct natural histories. Moreover, these novel technologies may offer an optimal strategy to evaluate the effectiveness of novel therapies and therapies targeting localized small airways disease in preclinical and clinical research. In this review, we aim to discuss the features of functional lung imaging, as well as its potential application and limitations to adoption in research.
Collapse
Affiliation(s)
- Dipan Karmali
- Division of Pulmonary and Critical Care, Leonard M. Miller School of Medicine, University of Miami, Coral Gables, FL, United States
| | - Mudiaga Sowho
- Division of Pulmonary and Critical Care Medicine, Johns Hopkins School of Medicine, Baltimore, MD, United States
| | - Sonali Bose
- Division of Pulmonary and Critical Care, Icahn School of Medicine, Mount Sinai, NY, United States
| | - Jackson Pearce
- School of Medicine, Medical University of South Carolina, Charleston, SC, United States
| | - Vickram Tejwani
- Respiratory Institute, Cleveland Clinic, Cleveland, OH, United States
| | - Zuzana Diamant
- Department of Microbiology Immunology and Transplantation, KU Leuven, Catholic University of Leuven, Leuven, Belgium
- Department of Respiratory Medicine and Allergology, Institute for Clinical Science, Skane University Hospital, Lund University, Lund, Sweden
- Department Clinical Pharmacy and Pharmacology, University of Groningen, University Medical Center Groningen, Groningen, Netherlands
| | - Keerthi Yarlagadda
- Division of Pulmonary and Critical Care, Leonard M. Miller School of Medicine, University of Miami, Coral Gables, FL, United States
| | - Erick Ponce
- Division of Pulmonary and Critical Care, Leonard M. Miller School of Medicine, University of Miami, Coral Gables, FL, United States
| | | | | | - Akram Khan
- Division of Pulmonary and Critical Care, Oregon Health and Science University, Portland, OR, United States
| | - Michael Lester
- Department of Pulmonary and Critical Care Medicine, Vanderbilt Medical Center, Nashville, CA, United States
| | | | | | - Trishul Siddharthan
- Division of Pulmonary and Critical Care, Leonard M. Miller School of Medicine, University of Miami, Coral Gables, FL, United States
| |
Collapse
|
6
|
Kimura A, Utsumi S, Shimokawa A, Nishimori R, Hosoi R, Stewart NJ, Imai H, Fujiwara H. Targeted Imaging of Lung Cancer with Hyperpolarized 129Xe MRI Using Surface-Modified Iron Oxide Nanoparticles as Molecular Contrast Agents. Cancers (Basel) 2022; 14:cancers14246070. [PMID: 36551556 PMCID: PMC9776850 DOI: 10.3390/cancers14246070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/07/2022] [Accepted: 12/07/2022] [Indexed: 12/14/2022] Open
Abstract
Hyperpolarized 129Xe (HP 129Xe) MRI enables functional imaging of various lung diseases but has been scarcely applied to lung cancer imaging. The aim of this study is to investigate the feasibility of targeted imaging of lung cancer with HP 129Xe MRI using surface-modified iron oxide nanoparticles (IONPs) as molecular targeting contrast agents. A mouse model of lung cancer (LC) was induced in nine mice by intra-peritoneal injection of urethane. Three months after the urethane administration, the mice underwent lung imaging with HP 129Xe MRI at baseline (0 h). Subsequently, the LC group was divided into two sub-groups: mice administered with polyethylene glycol-coated IONPs (PEG-IONPs, n = 4) and folate-conjugated dextran-coated IONPs (FA@Dex-IONPs, n = 5). The mice were imaged at 3, 6, and 24 h after the intravenous injection of IONPs. FA@Dex-IONPs mice showed a 25% reduction in average signal intensity at cancer sites at 3 h post injection, and a 24% reduction at 24 h post injection. On the other hand, in PEG-IONPs mice, while a signal reduction of approximately 28% was observed at cancer sites at 3 to 6 h post injection, the signal intensity was unchanged from that of the baseline at 24 h. Proton MRI of LC mice (n = 3) was able to detect cancer five months after urethane administration, i.e., later than HP 129Xe MRI (3 months). Furthermore, a significant decrease in averaged 1H T2 values at cancer sites was observed at only 6 h post injection of FA@Dex-IONPs (p < 0.05). As such, the targeted delivery of IONPs to cancer tissue was successfully imaged with HP 129Xe MRI, and their surface modification with folate likely has a high affinity with LC, which causes overexpression of folate receptors.
Collapse
Affiliation(s)
- Atsuomi Kimura
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate School of Medicine, Osaka University, Osaka 565-0871, Japan
- Correspondence: ; Tel.: +81-6-6879-2578
| | - Seiya Utsumi
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate School of Medicine, Osaka University, Osaka 565-0871, Japan
| | - Akihiro Shimokawa
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate School of Medicine, Osaka University, Osaka 565-0871, Japan
| | - Renya Nishimori
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate School of Medicine, Osaka University, Osaka 565-0871, Japan
| | - Rie Hosoi
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate School of Medicine, Osaka University, Osaka 565-0871, Japan
| | - Neil J. Stewart
- POLARIS, Imaging Sciences, Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield S10 2TA, UK
| | - Hirohiko Imai
- Division of Systems Informatics, Department of Systems Science, Graduate School of Informatics, Kyoto University, Kyoto 606-8561, Japan
| | - Hideaki Fujiwara
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate School of Medicine, Osaka University, Osaka 565-0871, Japan
| |
Collapse
|
7
|
Preclinical MRI Using Hyperpolarized 129Xe. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27238338. [PMID: 36500430 PMCID: PMC9738892 DOI: 10.3390/molecules27238338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/15/2022] [Accepted: 11/17/2022] [Indexed: 12/05/2022]
Abstract
Although critical for development of novel therapies, understanding altered lung function in disease models is challenging because the transport and diffusion of gases over short distances, on which proper function relies, is not readily visualized. In this review we summarize progress introducing hyperpolarized 129Xe imaging as a method to follow these processes in vivo. The work is organized in sections highlighting methods to observe the gas replacement effects of breathing (Gas Dynamics during the Breathing Cycle) and gas diffusion throughout the parenchymal airspaces (3). We then describe the spectral signatures indicative of gas dissolution and uptake (4), and how these features can be used to follow the gas as it enters the tissue and capillary bed, is taken up by hemoglobin in the red blood cells (5), re-enters the gas phase prior to exhalation (6), or is carried via the vasculature to other organs and body structures (7). We conclude with a discussion of practical imaging and spectroscopy techniques that deliver quantifiable metrics despite the small size, rapid motion and decay of signal and coherence characteristic of the magnetically inhomogeneous lung in preclinical models (8).
Collapse
|
8
|
Shepelytskyi Y, Grynko V, Rao MR, Li T, Agostino M, Wild JM, Albert MS. Hyperpolarized 129 Xe imaging of the brain: Achievements and future challenges. Magn Reson Med 2022; 88:83-105. [PMID: 35253919 PMCID: PMC9314594 DOI: 10.1002/mrm.29200] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 12/22/2021] [Accepted: 01/25/2022] [Indexed: 11/25/2022]
Abstract
Hyperpolarized (HP) xenon-129 (129 Xe) brain MRI is a promising imaging modality currently under extensive development. HP 129 Xe is nontoxic, capable of dissolving in pulmonary blood, and is extremely sensitive to the local environment. After dissolution in the pulmonary blood, HP 129 Xe travels with the blood flow to the brain and can be used for functional imaging such as perfusion imaging, hemodynamic response detection, and blood-brain barrier permeability assessment. HP 129 Xe MRI imaging of the brain has been performed in animals, healthy human subjects, and in patients with Alzheimer's disease and stroke. In this review, the overall progress in the field of HP 129 Xe brain imaging is discussed, along with various imaging approaches and pulse sequences used to optimize HP 129 Xe brain MRI. In addition, current challenges and limitations of HP 129 Xe brain imaging are discussed, as well as possible methods for their mitigation. Finally, potential pathways for further development are also discussed. HP 129 Xe MRI of the brain has the potential to become a valuable novel perfusion imaging technique and has the potential to be used in the clinical setting in the future.
Collapse
Affiliation(s)
- Yurii Shepelytskyi
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada
| | - Vira Grynko
- Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Chemistry and Materials Science Program, Lakehead University, Thunder Bay, Ontario, Canada
| | - Madhwesha R Rao
- POLARIS, Unit of Academic Radiology, Department of IICD, University of Sheffield, Sheffield, UK
| | - Tao Li
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Martina Agostino
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Jim M Wild
- POLARIS, Unit of Academic Radiology, Department of IICD, University of Sheffield, Sheffield, UK.,Insigneo Institute for in Silico Medicine, Sheffield, UK
| | - Mitchell S Albert
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada
| |
Collapse
|
9
|
Wakayama T, Ueyama T, Imai F, Kimura A, Fujiwara H. Quantitative assessment of regional lung ventilation in emphysematous mice using hyperpolarized 129Xe MRI with a continuous flow hyperpolarizing system. Magn Reson Imaging 2022; 92:88-95. [PMID: 35654279 DOI: 10.1016/j.mri.2022.05.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 05/23/2022] [Accepted: 05/24/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND Lung ventilation function in small animals can be assessed by using hyperpolarized gas MRI. For these experiments a free breathing protocol is generally preferred to mechanical ventilation as mechanical ventilation can often lead to ventilation lung injury, while the need to maintain a gas reservoir may lead to a partial reduction of the polarization. PURPOSE To evaluate regional lung ventilation of mice by a simple but fast method under free breathing and give evidence for effectiveness with an elastase instilled emphysematous mice. ANIMAL MODEL Emphysematous mice. MATERIALS AND METHODS A Look-Locker based saturation recovery sequence was developed for continuous flow hyperpolarized (CF-HP) 129Xe gas experiments, and the apparent gas-exchange rate, k', was measured by the analysis of the saturation recovery curve. RESULTS In mice with elastase-induced mild emphysema, reductions of 15-30% in k' values were observed as the results of lesion-induced changes in the lung. DATA CONCLUSION The proposed method was applied to an emphysematous model mice and ventilation dysfunctions have been approved as a definite decrease in k' values, supporting the usefulness for a non-invasive assessment of the lung functions in preclinical study by the CF-HP 129Xe experiments.
Collapse
Affiliation(s)
- Tetsuya Wakayama
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate of School of Medicine, Osaka University, 1-7 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Tsuyoshi Ueyama
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate of School of Medicine, Osaka University, 1-7 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Fumito Imai
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate of School of Medicine, Osaka University, 1-7 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Atsuomi Kimura
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate of School of Medicine, Osaka University, 1-7 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Hideaki Fujiwara
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Graduate of School of Medicine, Osaka University, 1-7 Yamadaoka, Suita, Osaka 565-0871, Japan.
| |
Collapse
|
10
|
Hamedani H, Kadlecek S, Ruppert K, Xin Y, Duncan I, Rizi RR. Ventilation heterogeneity imaged by multibreath wash-ins of hyperpolarized 3 He and 129 Xe in healthy rabbits. J Physiol 2021; 599:4197-4223. [PMID: 34256417 DOI: 10.1113/jp281584] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 06/30/2021] [Indexed: 12/20/2022] Open
Abstract
KEY POINTS Multibreath imaging to estimate regional gas mixing efficiency is superior to intensity-based single-breath ventilation markers, as it is capable of revealing minute but essential measures of ventilation heterogeneity which may be sensitive to subclinical alterations in the early stages of both obstructive and restrictive respiratory disorders. Large-scale convective stratification of ventilation in central-to-peripheral directions is the dominant feature of observed ventilation heterogeneity when imaging a heavy/less diffusive xenon gas mixture; smaller-scale patchiness, probably originating from asymmetric lung function at bronchial airway branching due to the interaction of convective and diffusive flows, is the dominant feature when imaging a lighter/more diffusive helium gas mixture. Since detecting low regional ventilation is crucial for characterizing diseased lungs, our results suggest that dilution with natural abundance helium and imaging at higher lung volumes seem advisable when imaging with hyperpolarized 129 Xe; this will allow the imaging gas to reach slow-filling and/or non-dependent lung regions, which might otherwise be impossible to distinguish from total ventilation shunt regions. The ability to differentiate these regions from those of total shunt is worse with typical single-breath imaging techniques. ABSTRACT The mixing of freshly inhaled gas with gas already present in the lung can be directly assessed with heretofore unachievable precision via magnetic resonance imaging of signal build-up resulting from multiple wash-ins of a hyperpolarized (HP) gas. Here, we used normoxic HP 3 He and 129 Xe mixtures to study regional ventilation at different spatial scales in five healthy mechanically ventilated supine rabbits at two different inspired volumes. To decouple the respective effects of density and diffusion rates on ventilation heterogeneity, two additional studies were performed: one in which 3 He was diluted with an equal fraction of natural abundance xenon, and one in which 129 Xe was diluted with an equal fraction of 4 He. We observed systematic differences in the spatial scale of specific ventilation heterogeneity between HP 3 He and 129 Xe. We found that large-scale, central-to-peripheral convective ventilation inhomogeneity is the dominant cause of observed heterogeneity when breathing a normoxic xenon gas mixture. In contrast, small-scale ventilation heterogeneity in the form of patchiness, probably originating from asymmetric lung function at bronchial airway branching due to interactions between convective and diffusive flows, is the dominant feature when breathing a normoxic helium gas mixture, for which the critical zone occurs more proximally and at an imageable spatial scale. We also showed that the existence of particular underventilated non-dependent lung regions when breathing a heavy gas mixture is the result of the density of that mixture - rather than, for example, its diffusion rate or viscosity. Finally, we showed that gravity-dependent ventilation heterogeneity becomes substantially more uniform at higher inspired volumes for xenon gas mixtures compared to helium mixtures.
Collapse
Affiliation(s)
- Hooman Hamedani
- Department of Radiology, Functional and Metabolic Imaging Group, University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Penn Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Stephen Kadlecek
- Department of Radiology, Functional and Metabolic Imaging Group, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Kai Ruppert
- Department of Radiology, Functional and Metabolic Imaging Group, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Yi Xin
- Department of Radiology, Functional and Metabolic Imaging Group, University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Penn Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ian Duncan
- Department of Radiology, Functional and Metabolic Imaging Group, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Rahim R Rizi
- Department of Radiology, Functional and Metabolic Imaging Group, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
11
|
Grynko V, Shepelytskyi Y, Li T, Hassan A, Granberg K, Albert MS. Hyperpolarized 129 Xe multi-slice imaging of the human brain using a 3D gradient echo pulse sequence. Magn Reson Med 2021; 86:3175-3181. [PMID: 34272774 DOI: 10.1002/mrm.28932] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 06/10/2021] [Accepted: 06/30/2021] [Indexed: 12/14/2022]
Abstract
PURPOSE To demonstrate the possibility of performing multi-slice in-vivo human brain MRI using hyperpolarized (HP) xenon-129 (129 Xe) in two different orientations and to calculate the signal-to-noise ratio (SNR). METHODS Two healthy female participants were imaged during a single breath-hold of HP 129 Xe using a Philips Achieva 3.0T MRI scanner (Philips, Andover, MA). Each HP 129 Xe multi-slice brain image was acquired during separate HP 129 Xe breath-holds using 3D gradient echo (GRE) imaging. The acquisition started 10 s after the inhalation of 1 L of HP 129 Xe. Overall, four sagittal and three axial images were acquired (seven imaging sessions per participant). The SNR was calculated for each slice in both orientations. RESULTS The first ever HP 129 Xe multi-slice images of the brain were acquired in axial and sagittal orientations. The HP 129 Xe signal distribution correlated well with the gray matter distribution. The highest SNR values were close in the axial and sagittal orientations (19.46 ± 3.25 and 18.76 ± 4.94, respectively). Additionally, anatomical features, such as the ventricles, were observed in both orientations. CONCLUSION The possibility of using multi-slice HP 129 Xe human brain magnetic resonance imaging was demonstrated for the first time. HP 129 Xe multi-slice MRI can be implemented for brain imaging to improve current diagnostic methods.
Collapse
Affiliation(s)
- Vira Grynko
- Chemistry and Materials Science Program, Lakehead University, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada
| | - Yurii Shepelytskyi
- Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Tao Li
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Ayman Hassan
- Thunder Bay Regional Health Sciences Centre, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada
| | - Karl Granberg
- Thunder Bay Regional Health Sciences Centre, Thunder Bay, Ontario, Canada
| | - Mitchell S Albert
- Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada
| |
Collapse
|
12
|
Shepelytskyi Y, Grynko V, Li T, Hassan A, Granberg K, Albert MS. The effects of an initial depolarization pulse on dissolved phase hyperpolarized 129 Xe brain MRI. Magn Reson Med 2021; 86:3147-3155. [PMID: 34254356 DOI: 10.1002/mrm.28918] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 06/01/2021] [Accepted: 06/16/2021] [Indexed: 12/27/2022]
Abstract
PURPOSE To evaluate the effect of an initial 90° depolarization RF pulse on the dissolved-phase hyperpolarized (HP) xenon-129 (129 Xe) brain imaging and to compare the SNR variability of HP 129 Xe images acquired without an initial depolarization RF pulse to those following the initial depolarization pulse. METHODS Five cognitive normal healthy volunteers were imaged using a Philips Achieva 3.0T MRI scanner during a single breath-hold following inhalation of 1 L of HP 129 Xe. Each participant underwent six HP 129 Xe scans. Three scans were performed using conventional single-slice projection HP 129 Xe brain imaging, and the other three scans were performed using the HP 129 Xe time-of-flight imaging with an initial rectangular depolarization pulse. RESULTS Although the utilization of an initial depolarization results in the reduction of the mean image SNR, the presence of an initial depolarization RF pulse reduces the SNR variability of the HP 129 Xe brain image by a factor of 2.26. The highest SNR variability was observed from the posterior brain region, where the anterior region possessed the lower level of signal variability. CONCLUSION An initial 90° depolarization RF pulse, applied prior to the HP 129 Xe image acquisition, reduced the HP 129 Xe signal variability more than two times between the different breath-hold images.
Collapse
Affiliation(s)
- Yurii Shepelytskyi
- Department of Chemistry, Lakehead University, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada
| | - Vira Grynko
- Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Chemistry and Materials Science Program, Lakehead University, Thunder Bay, Ontario, Canada
| | - Tao Li
- Department of Chemistry, Lakehead University, Thunder Bay, Ontario, Canada
| | - Ayman Hassan
- Thunder Bay Regional Health Sciences Centre, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada
| | - Karl Granberg
- Thunder Bay Regional Health Sciences Centre, Thunder Bay, Ontario, Canada
| | - Mitchell S Albert
- Department of Chemistry, Lakehead University, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada
| |
Collapse
|
13
|
Inflammation during Lung Cancer Progression and Ethyl Pyruvate Treatment Observed by Pulmonary Functional Hyperpolarized 129Xe MRI in Mice. CONTRAST MEDIA & MOLECULAR IMAGING 2021; 2021:9918702. [PMID: 34257627 PMCID: PMC8261185 DOI: 10.1155/2021/9918702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 06/08/2021] [Accepted: 06/17/2021] [Indexed: 11/17/2022]
Abstract
This study aimed to assess the suitability of hyperpolarized 129Xe (HPXe) MRI for noninvasive longitudinal evaluation of pulmonary function in preclinical lung cancer models. A mouse model of lung cancer (LC) was induced in 5 mice by intraperitoneal injection of urethane, while a negative-control (NC) mice (N = 5) was prepared by injection of saline solution. Longitudinal HPXe MRI was performed over a 5-month period to monitor lung ventilation and gas exchange. The treatment efficacy of ethyl pyruvate (EP), an anti-inflammatory drug, to the mouse LC model was monitored using HPXe MRI by commencing administration of EP pre (early-phase) and 1-month post (late-phase) injection of urethane (N = 5 mice for each group). Gas-exchange function in LC mice was significantly reduced at 1-month after urethane injection compared with NC mice administered with saline (P < 0.01). Thereafter, it remained consistently lower than that of the NC group for the full 5-month measurement period. In contrast, the ventilation function of the LC model mice was not significantly different to that of the NC mice. Histological analysis revealed alveolar epithelial hyperplasia in LC mice alveoli at 1 month after urethane injection, and adenoma was confirmed 3 months after the injection. The early- and late-phase EP interventions were found to improve HPXe MRI metrics (reduced at 1 month postinjection of urethane) and significantly inhibit tumor growth. These results suggest that HPXe MRI gas-exchange metrics can be used to quantitatively assess changes in the precancerous lesion microenvironment and to evaluate therapeutic efficacy in cancer. Thus, HPXe MRI can be utilized to noninvasively monitor pulmonary pathology during LC progression and can visualize functional changes during therapy.
Collapse
|
14
|
Niedbalski PJ, Cleveland ZI. Improved preclinical hyperpolarized 129 Xe ventilation imaging with constant flip angle 3D radial golden means acquisition and keyhole reconstruction. NMR IN BIOMEDICINE 2021; 34:e4464. [PMID: 33354833 PMCID: PMC8482370 DOI: 10.1002/nbm.4464] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 06/16/2020] [Accepted: 12/06/2020] [Indexed: 06/12/2023]
Abstract
Hyperpolarized (HP) 129 Xe MRI is increasingly used to noninvasively probe regional lung structure and function in the preclinical setting. As in human imaging, the primary barrier to quantitative imaging with HP gases is nonequilibrium magnetization, which is depleted by T1 relaxation and radio frequency excitation. Preclinical HP gas imaging commonly involves mechanically ventilating small animals and encoding k-space over tens or hundreds of breaths, with small subsets of k-space data collected within each breath. Breath-to-breath magnetization renewal enables the use of large flip angles, but the resulting magnetization decay generates large view-to-view differences in within-breath signal intensity, leading to artifacts and degraded image quality. This deleterious signal decay has motivated the use of variable flip angle (VFA) sampling schemes, in which the flip angle is progressively increased to maintain constant view-to-view signal intensity. However, VFA imaging complicates data acquisition and provides only a global correction that fails to compensate for regional differences in signal dynamics. When constant flip angle (CFA) imaging is used alongside 3D radial golden means acquisition, the center of k-space is sampled with every excitation, thereby encoding signal dynamics alongside imaging data. Here, keyhole reconstruction is used to generate multiple images to capture in-breath HP 129 Xe signal dynamics in mice and thus provide flip angle maps to quantitatively correct images without extra data collection. These CFA images display SNR that is not significantly different from VFA images, and further, high frequency k-space scaling can be used to mitigate decay-induced image artifacts. Results are supported by point spread function calculations and simulations of radial imaging with preclinical signal dynamics. Together, these results show that CFA 3D radial golden means ventilation imaging provides comparable image quality with VFA in small animals and allows for keyhole reconstruction, which can be used to generate flip angle maps and correct images for signal depletion.
Collapse
Affiliation(s)
- Peter J. Niedbalski
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229
| | - Zackary I. Cleveland
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH 45221
- Imaging Research Center, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| |
Collapse
|
15
|
Yang Y, Zhang Y, Wang B, Guo Q, Yuan Y, Jiang W, Shi L, Yang M, Chen S, Lou X, Zhou X. Coloring ultrasensitive MRI with tunable metal-organic frameworks. Chem Sci 2021; 12:4300-4308. [PMID: 34163694 PMCID: PMC8179523 DOI: 10.1039/d0sc06969h] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
As one of the most important imaging modalities, magnetic resonance imaging (MRI) still faces relatively low sensitivity to monitor low-abundance molecules. A newly developed technology, hyperpolarized 129Xe magnetic resonance imaging (MRI), can boost the signal sensitivity to over 10 000-fold compared with that under conventional MRI conditions, and this technique is referred to as ultrasensitive MRI. However, there are few methods to visualize complex mixtures in this field due to the difficulty in achieving favorable “cages” to capture the signal source, namely, 129Xe atoms. Here, we proposed metal–organic frameworks (MOFs) as tunable nanoporous hosts to provide suitable cavities for xenon. Due to the widely dispersed spectroscopic signals, 129Xe in different MOFs was easily visualized by assigning each chemical shift to a specific color. The results illustrated that the pore size determined the exchange rate, and the geometric structure and elemental composition influenced the local charge experienced by xenon. We confirmed that a complex mixture was first differentiated by specific colors in ultrasensitive MRI. The introduction of MOFs helps to overcome long-standing obstacles in ultrasensitive, multiplexed MRI. Metal organic frameworks with tunable pore structures are able to provide varied chemical environments for hyperpolarized 129Xe atom hosting, which results in distinguishing magnetic resonance signals, and stains ultra-sensitive magnetic resonance imaging (MRI) with diverse colors.![]()
Collapse
Affiliation(s)
- Yuqi Yang
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics Wuhan 430071 China .,University of Chinese Academy of Sciences Beijing 100049 China
| | - Yingfeng Zhang
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics Wuhan 430071 China
| | - Baolong Wang
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics Wuhan 430071 China
| | - Qianni Guo
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics Wuhan 430071 China .,University of Chinese Academy of Sciences Beijing 100049 China
| | - Yaping Yuan
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics Wuhan 430071 China .,University of Chinese Academy of Sciences Beijing 100049 China
| | - Weiping Jiang
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics Wuhan 430071 China .,University of Chinese Academy of Sciences Beijing 100049 China
| | - Lei Shi
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics Wuhan 430071 China .,University of Chinese Academy of Sciences Beijing 100049 China
| | - Minghui Yang
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics Wuhan 430071 China .,University of Chinese Academy of Sciences Beijing 100049 China
| | - Shizhen Chen
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics Wuhan 430071 China .,University of Chinese Academy of Sciences Beijing 100049 China
| | - Xin Lou
- Department of Radiology, Chinese PLA General Hospital Beijing 100039 China
| | - Xin Zhou
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics Wuhan 430071 China .,University of Chinese Academy of Sciences Beijing 100049 China
| |
Collapse
|
16
|
Parsons D, Donnelley M. Will Airway Gene Therapy for Cystic Fibrosis Improve Lung Function? New Imaging Technologies Can Help Us Find Out. Hum Gene Ther 2020; 31:973-984. [PMID: 32718206 DOI: 10.1089/hum.2020.153] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
The promise of genetic therapies has turned into reality in recent years, with new first-line treatments for fatal diseases now available to patients. The development and testing of genetic therapies for respiratory diseases such as cystic fibrosis (CF) has also progressed. The addition of gene editing to the genetic agent toolbox, and its early success in other organ systems, suggests we will see rapid expansion of gene correction options for CF in the future. Although substantial progress has been made in creating techniques and genetic agents that can be highly effective for CF correction in vitro, physiologically relevant functional in vivo changes have been largely prevented by poor delivery efficiency within the lungs. Somewhat hidden from view, however, is the absence of reliable, accurate, detailed, and noninvasive outcome measures that can detect subtle disease and treatment effects in the lungs of humans or animal models. The ability to measure the fundamental function of the lung-ventilation, the effective transport of air throughout the lung-has been constrained by the available measurement technologies. Without sensitive measurement methods, it is difficult to quantify the effectiveness of genetic therapies for CF. The mainstays of lung health assessment are spirometry, which cannot provide adequate disease localization and is not sensitive enough to detect small early changes in disease; and computed tomography, which provides structural rather than functional information. Magnetic resonance imaging using hyperpolarized gases is increasingly useful for lung ventilation assessment, and it removes the radiation risk that accompanies X-ray methods. A new lung imaging technique, X-ray velocimetry, can now offer highly detailed regional lung ventilation information well suited to the diagnosis, treatment, and monitoring needs of CF lung disease, particularly after the application of genetic therapies. In this review, we discuss the options now available for imaging-based lung function measurement in the generation and use of genetic and other therapies for treating CF lung disease.
Collapse
Affiliation(s)
- David Parsons
- Robinson Research Institute, University of Adelaide, Adelaide, Australia.,Adelaide Medical School, University of Adelaide, Adelaide, Australia.,Respiratory and Sleep Medicine, Women's and Children's Hospital, North Adelaide, Australia
| | - Martin Donnelley
- Robinson Research Institute, University of Adelaide, Adelaide, Australia.,Adelaide Medical School, University of Adelaide, Adelaide, Australia.,Respiratory and Sleep Medicine, Women's and Children's Hospital, North Adelaide, Australia
| |
Collapse
|
17
|
Hyperpolarized 129Xe Time-of-Flight MR Imaging of Perfusion and Brain Function. Diagnostics (Basel) 2020; 10:diagnostics10090630. [PMID: 32854196 PMCID: PMC7554935 DOI: 10.3390/diagnostics10090630] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 08/22/2020] [Accepted: 08/23/2020] [Indexed: 02/07/2023] Open
Abstract
Perfusion measurements can provide vital information about the homeostasis of an organ and can therefore be used as biomarkers to diagnose a variety of cardiovascular, renal, and neurological diseases. Currently, the most common techniques to measure perfusion are 15O positron emission tomography (PET), xenon-enhanced computed tomography (CT), single photon emission computed tomography (SPECT), dynamic contrast enhanced (DCE) MRI, and arterial spin labeling (ASL) MRI. Here, we show how regional perfusion can be quantitively measured with magnetic resonance imaging (MRI) using time-resolved depolarization of hyperpolarized (HP) xenon-129 (129Xe), and the application of this approach to detect changes in cerebral blood flow (CBF) due to a hemodynamic response in response to brain stimuli. The investigated HP 129Xe Time-of-Flight (TOF) technique produced perfusion images with an average signal-to-noise ratio (SNR) of 10.35. Furthermore, to our knowledge, the first hemodynamic response (HDR) map was acquired in healthy volunteers using the HP 129Xe TOF imaging. Responses to visual and motor stimuli were observed. The acquired HP TOF HDR maps correlated well with traditional proton blood oxygenation level-dependent functional MRI. Overall, this study expands the field of HP MRI with a novel dynamic imaging technique suitable for rapid and quantitative perfusion imaging.
Collapse
|