Xu P, Wu H, Shen G. Characterization of weakly nonlinear effects in relationship to transducer parameters in focused ultrasound therapy. Med Phys 2024; 51:7619-7631. [PMID: 38935266 DOI: 10.1002/mp.17270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 06/04/2024] [Accepted: 06/13/2024] [Indexed: 06/28/2024] Open
Abstract
BACKGROUND Focused ultrasound therapy has been widely used for the treatment of various diseases, employing different types of transducers. The focused ultrasound pressure fields inevitably exhibit nonlinear effects, which can influence the ablation region. However, the nonlinear effects exhibit noticeable variations across different applications. The characterization of the nonlinear pressure fields of ultrasound is important for the effective implementation of focused ultrasound therapy. PURPOSE The traditional angular spectrum method (ASM) was extended to accurately and efficiently simulate the propagation of weakly nonlinear ultrasound in heterogeneous mediums of clinical model. The nonlinear effects were further analyzed in relationship to the transducer parameters that are different in various applications. METHODS The pressure fields were simulated using the extended ASM, incorporating calculations for phase aberration in the frequency domain and magnitude compensation in the spatial domain to account for heterogeneous acoustic impedance mismatch. Validation was performed by comparison to k-Wave simulation results using two simplified clinical models, an abdominal soft tissue and a transcranial skull model. The nonlinear effects were then analyzed in relation to the transducer parameters of f-number and effective source area based on the same acoustic output power. The analysis of nonlinear effects was conducted under both homogeneous medium and the clinical models. RESULTS The simulation results demonstrated a maximum error of 3.93% in the calculated harmonic pressure of the abdominal model, and a maximum error of 4.89% within the transcranial model when comparing the extended ASM simulation results to those obtained from k-Wave simulations. The characterization of the nonlinear effects reveals a strong correlation with the transducer parameters. Specifically, the results indicate that the nonlinear effects intensify with an increase in the effective source area and f-number, under the same acoustic output power of the transducer. However, the clinical model also showed an influence on the nonlinear effects in relation to the f-number. CONCLUSION The extended ASM was demonstrated as an accurate and efficient simulation tool, and the simulation results provide a reference for evaluating the intensity of nonlinear effects in various transducer designs.
Collapse
Affiliation(s)
- Peng Xu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Hao Wu
- Shanghai Shende Green Medical Era Healthcare Technology Co., Ltd, Shanghai, People's Republic of China
| | - Guofeng Shen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| |
Collapse
|
2
|
Zhu H, Zeng Y, Cai X. Passive Acoustic Mapping for Convex Arrays With the Helical Wave Spectrum Method. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:1923-1933. [PMID: 38198274 DOI: 10.1109/tmi.2024.3352283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2024]
Abstract
Passive acoustic mapping (PAM) has emerged as a valuable imaging modality for monitoring the cavitation activity in focused ultrasound therapies. When it comes to imaging in the human abdomen, convex arrays are preferred due to their large acoustic window. However, existing PAM methods for convex arrays rely on the computationally expensive delay-and-sum (DAS) operation limiting the image reconstruction speed when the field-of-view (FOV) is large. In this work, we propose an efficient and frequency-selective PAM method for convex arrays. This method is based on projecting the helical wave spectrum (HWS) between cylindrical surfaces in the imaging field. Both the in silico and in vitro experiments showed that the HWS method has comparable image quality and similar acoustic cavitation source localization accuracy as the DAS-based methods. Compared to the frequency-domain and time-domain DAS methods, the time-complexity of the HWS method is reduced by one order and two orders of magnitude, respectively. A parallel implementation of the HWS method realized millisecond-level image reconstruction speed. We also show that the HWS method is inherently capable of mapping microbubble (MB) cavitation activity of different status, i.e., no cavitation, stable cavitation, or inertial cavitation. After compensating for the lens effects of the convex array, we further combined PAM formed by the HWS method and B-mode imaging as a real-time dual-mode imaging approach to map the anatomical location where MBs cavitate in a liver phantom experiment. This method may find use in applications where convex arrays are required for cavitation activity monitoring in real time.
Collapse
|
3
|
Shen F, Fan F, Li F, Wang L, Wang R, Wang Y, Liu T, Wei C, Niu H. An efficient method for transcranial ultrasound focus correction based on the coupling of boundary integrals and finite elements. ULTRASONICS 2024; 137:107181. [PMID: 37847943 DOI: 10.1016/j.ultras.2023.107181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 09/21/2023] [Accepted: 10/08/2023] [Indexed: 10/19/2023]
Abstract
Transcranial focused ultrasound is a novel technique for the noninvasive treatment of brain diseases. The success of the treatment greatly depends on achieving precise and efficient intraoperative focus. However, compensating for aberrated ultrasound waves caused by the skull through numerical simulation-based phase corrections is a challenging task due to the significant computational burden involved in solving the acoustic wave equation. In this article, we propose a promising strategy using the coupling of the boundary integral equation method (BIEM) and the finite element method (FEM) to overcome the above limitation. Specifically, we adopt the BIEM to obtain the Robin-to-Dirichlet maps on the boundaries of the skull and then couple the maps to the FEM matrices via a dual interpolation technique, resulting in a computational domain including only the skull. Three simulation experiments were conducted to evaluate the effectiveness of the proposed method, including a convergence test and two skull-induced aberration corrections in 2D and 3D ultrasound. The results show that the method's convergence is guaranteed as the element size decreases, leading to a decrease in pressure error. The computation times for simulating a 500 kHz ultrasound field on a regular desktop computer were found to be 0.47 ± 0.01 s in the 2D case and 43.72 ± 1.49 s in the 3D case, provided that lower-upper decomposition (approximately 13 s in 2D and 2.5 h in 3D) was implemented in advance. We also demonstrated that more accurate transcranial focusing can be achieved by phase correction compared to the noncorrected results (with errors of 1.02 mm vs. 6.45 mm in 2D and 0.28 mm vs. 3.07 mm in 3D). The proposed strategy is valuable for enabling online ultrasound simulations during treatment, facilitating real-time adjustments and interventions.
Collapse
Affiliation(s)
- Fei Shen
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Fan Fan
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Fengji Li
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Li Wang
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Rui Wang
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yue Wang
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Tao Liu
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Cuibai Wei
- Department of Neurology, Xuan Wu Hospital, Capital Medical University, Beijing 100050, China
| | - Haijun Niu
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| |
Collapse
|
4
|
Singh A, Jiménez-Gambín S, Konofagou EE. An all-ultrasound cranial imaging method to establish the relationship between cranial FUS incidence angle and transcranial attenuation in non-human primates in 3D. Sci Rep 2024; 14:1488. [PMID: 38233480 PMCID: PMC10794232 DOI: 10.1038/s41598-024-51623-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Accepted: 01/08/2024] [Indexed: 01/19/2024] Open
Abstract
Focused ultrasound (FUS) is a non-invasive and non-ionizing technique which deploys ultrasound waves to induce bio-effects. When paired with acoustically active particles such as microbubbles (MBs), it can open the blood brain barrier (BBB) to facilitate drug delivery otherwise inhibited due to the presence of BBB. One of the parameters that affects the FUS beam propagation is the beam incidence angle on the skull. Prior work by our group has shown that, as incidence angles deviate from 90°, FUS focal pressures attenuate and result in a smaller BBB opening volume. The incidence angles calculated in our prior studies were in 2D and used skull information from CT. The study presented herein develops methods to calculate incidence angle in 3D in non-human primate (NHP) skull fragments using harmonic ultrasound imaging without using ionizing radiation. Our results show that ultrasound harmonic imaging is capable of accurately depicting features such as sutures and eye-sockets of the skull. Furthermore, we were able to reproduce previously reported relationships between the incidence angle and FUS beam attenuation. We also show feasibility of performing ultrasound harmonic imaging in in-vivo non-human primates. The all-ultrasound method presented herein combined with our neuronavigation system stands to increase more widespread adoption of FUS and render it accessible by eliminating the need for CT cranial mapping.
Collapse
Affiliation(s)
- Aparna Singh
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | | | - Elisa E Konofagou
- Department of Biomedical Engineering, Columbia University, New York, NY, USA.
- Department of Radiology, Columbia University, New York, NY, USA.
| |
Collapse
|
5
|
Xu P, Wu N, Shen G. A rapid element pressure field simulation method for transcranial phase correction in focused ultrasound therapy. Phys Med Biol 2023; 68:235015. [PMID: 37934058 DOI: 10.1088/1361-6560/ad0a59] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 11/07/2023] [Indexed: 11/08/2023]
Abstract
Transcranial focused ultrasound ablation has emerged as a promising technique for treating neurological disorders. The clinical system exclusively employed the ray tracing method to compute phase aberrations induced by the human skull, taking into account computational time constraints. However, this method compromises slightly on accuracy compared to simulation-based methods. This study evaluates a fast simulation method that simulates the time-harmonic pressure field within the region of interest for effective phase correction. Experimental validation was carried out using a 512-element, 670 kHz hemispherical transducer for fourex vivoskulls. The ray tracing method achieved a restoration ratio of 64.81% ± 4.33% of acoustic intensity normalized to hydrophone measurements. In comparison, the rapid simulation method demonstrated improved results with a restoration ratio of 73.10% ± 7.46%, albeit slightly lower than the full-wave simulation which achieved a restoration ratio of 75.87% ± 5.40%. The rapid simulation methods exhibited computational times that were less than five minutes for parallel computation with 8 threads. The incident angle was calculated, and a maximum difference of 6.8 degrees was found when the fixed position of the skull was changed. Meanwhile, the restoration ratio of acoustic intensity was validated to be above 70% for different target positions away from the geometrical focus of the transducer. The favorable balance between time consumption and correction accuracy makes this method valuable for clinical treatment applications.
Collapse
Affiliation(s)
- Peng Xu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Nan Wu
- Shanghai Shende Green Medical Era Healthcare Technology Co., Ltd., Shanghai, People's Republic of China
| | - Guofeng Shen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| |
Collapse
|
6
|
Bae S, Liu K, Pouliopoulos AN, Ji R, Konofagou EE. Real-Time Passive Acoustic Mapping With Enhanced Spatial Resolution in Neuronavigation-Guided Focused Ultrasound for Blood-Brain Barrier Opening. IEEE Trans Biomed Eng 2023; 70:2874-2885. [PMID: 37159313 PMCID: PMC10538424 DOI: 10.1109/tbme.2023.3266952] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
OBJECTIVE Passive acoustic mapping (PAM) provides the spatial information of acoustic energy emitted from microbubbles during focused ultrasound (FUS), which can be used for safety and efficacy monitoring of blood-brain barrier (BBB) opening. In our previous work with a neuronavigation-guided FUS system, only part of the cavitation signal could be monitored in real time due to the computational burden although full-burst analysis is required to detect transient and stochastic cavitation activity. In addition, the spatial resolution of PAM can be limited for a small-aperture receiving array transducer. For full-burst real-time PAM with enhanced resolution, we developed a parallel processing scheme for coherence-factor-based PAM (CF-PAM) and implemented it onto the neuronavigation-guided FUS system using a co-axial phased-array imaging transducer. METHODS Simulation and in-vitro human skull studies were conducted for the performance evaluation of the proposed method in terms of spatial resolution and processing speed. We also carried out real-time cavitation mapping during BBB opening in non-human primates (NHPs). RESULTS CF-PAM with the proposed processing scheme provided better resolution than that of traditional time-exposure-acoustics PAM with a higher processing speed than that of eigenspace-based robust Capon beamformer, which facilitated the full-burst PAM with the integration time of 10 ms at a rate of 2 Hz. In vivo feasibility of PAM with the co-axial imaging transducer was also demonstrated in two NHPs, showing the advantages of using real-time B-mode and full-burst PAM for accurate targeting and safe treatment monitoring. SIGNIFICANCE This full-burst PAM with enhanced resolution will facilitate the clinical translation of online cavitation monitoring for safe and efficient BBB opening.
Collapse
|
7
|
Lee H, Guo Y, Ross JL, Schoen S, Degertekin FL, Arvanitis C. Spatially targeted brain cancer immunotherapy with closed-loop controlled focused ultrasound and immune checkpoint blockade. SCIENCE ADVANCES 2022; 8:eadd2288. [PMID: 36399574 PMCID: PMC9674274 DOI: 10.1126/sciadv.add2288] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Accepted: 10/21/2022] [Indexed: 05/28/2023]
Abstract
Despite the challenges in treating glioblastomas (GBMs) with immune adjuvants, increasing evidence suggests that targeting the immune cells within the tumor microenvironment (TME) can lead to improved responses. Here, we present a closed-loop controlled, microbubble-enhanced focused ultrasound (MB-FUS) system and test its abilities to safely and effectively treat GBMs using immune checkpoint blockade. The proposed system can fine-tune the exposure settings to promote MB acoustic emission-dependent expression of the proinflammatory marker ICAM-1 and delivery of anti-PD1 in a mouse model of GBM. In addition to enhanced interaction of proinflammatory macrophages within the PD1-expressing TME and significant improvement in survival (P < 0.05), the combined treatment induced long-lived memory T cell formation within the brain that supported tumor rejection in rechallenge experiments. Collectively, our findings demonstrate the ability of MB-FUS to augment the therapeutic impact of immune checkpoint blockade in GBMs and reinforce the notion of spatially tumor-targeted (loco-regional) brain cancer immunotherapy.
Collapse
Affiliation(s)
- Hohyun Lee
- G.W. School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Yutong Guo
- G.W. School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - James L. Ross
- Department of Microbiology and Immunology, Emory University, Atlanta, GA, USA
- Emory Vaccine Center, Emory University School of Medicine, Atlanta, GA, USA
| | - Scott Schoen
- Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA
| | - F. Levent Degertekin
- G.W. School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Costas Arvanitis
- G.W. School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
- Georgia Institute of Technology and Emory University, Department of Biomedical Engineering, Atlanta, GA, USA
| |
Collapse
|
8
|
Schoen S, Dash P, Arvanitis CD. Experimental Demonstration of Trans-Skull Volumetric Passive Acoustic Mapping With the Heterogeneous Angular Spectrum Approach. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:534-542. [PMID: 34748486 PMCID: PMC10243207 DOI: 10.1109/tuffc.2021.3125670] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Real-time, 3-D, passive acoustic mapping (PAM) of microbubble dynamics during transcranial focused ultrasound (FUS) is essential for optimal treatment outcomes. The angular spectrum approach (ASA) potentially offers a very efficient method to perform PAM, as it can reconstruct specific frequency bands pertinent to microbubble dynamics and may be extended to correct aberrations caused by the skull. Here, we experimentally assess the abilities of heterogeneous ASA (HASA) to perform trans-skull PAM. Our experimental investigations demonstrate that the 3-D PAMs of a known 1-MHz source, constructed with HASA through an ex vivo human skull segment, reduced both the localization error (from 4.7 ± 2.3 to 2.3 ± 1.6 mm) and the number, size, and energy of spurious lobes caused by aberration, with the modest additional computational expense. While further improvements in the localization errors are expected with arrays with denser elements and larger aperture, our analysis revealed that experimental constraints associated with the array pitch and aperture (here, 1.8 mm and 2.5 cm, respectively) can be ameliorated by interpolation and peak finding techniques. Beyond the array characteristics, our analysis also indicated that errors in the registration (translation and rotation of ±5 mm and ±5°, respectively) of the skull segment to the array can lead to peak localization errors of the order of a few wavelengths. Interestingly, errors in the spatially dependent speed of sound in the skull (±20%) caused only subwavelength errors in the reconstructions, suggesting that registration is the most important determinant of point source localization accuracy. Collectively, our findings show that HASA can address source localization problems through the skull efficiently and accurately under realistic conditions, thereby creating unique opportunities for imaging and controlling the microbubble dynamics in the brain.
Collapse
|
9
|
Bancel T, Tiennot T, Aubry JF. Adaptive Ultrasound Focusing Through the Cranial Bone for Non-invasive Treatment of Brain Disorders. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:397-409. [DOI: 10.1007/978-3-030-91979-5_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
10
|
Schoen S, Kilinc MS, Lee H, Guo Y, Degertekin FL, Woodworth GF, Arvanitis C. Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound. Adv Drug Deliv Rev 2022; 180:114043. [PMID: 34801617 PMCID: PMC8724442 DOI: 10.1016/j.addr.2021.114043] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 09/27/2021] [Accepted: 11/04/2021] [Indexed: 02/06/2023]
Abstract
Brain tumors are particularly challenging malignancies, due to their location in a structurally and functionally distinct part of the human body - the central nervous system (CNS). The CNS is separated and protected by a unique system of brain and blood vessel cells which together prevent most bloodborne therapeutics from entering the brain tumor microenvironment (TME). Recently, great strides have been made through microbubble (MB) ultrasound contrast agents in conjunction with ultrasound energy to locally increase the permeability of brain vessels and modulate the brain TME. As we elaborate in this review, this physical method can effectively deliver a wide range of anticancer agents, including chemotherapeutics, antibodies, and nanoparticle drug conjugates across a range of preclinical brain tumors, including high grade glioma (glioblastoma), diffuse intrinsic pontine gliomas, and brain metastasis. Moreover, recent evidence suggests that this technology can promote the effective delivery of novel immunotherapeutic agents, including immune check-point inhibitors and chimeric antigen receptor T cells, among others. With early clinical studies demonstrating safety, and several Phase I/II trials testing the preclinical findings underway, this technology is making firm steps towards shaping the future treatments of primary and metastatic brain cancer. By elaborating on its key components, including ultrasound systems and MB technology, along with methods for closed-loop spatial and temporal control of MB activity, we highlight how this technology can be tuned to enable new, personalized treatment strategies for primary brain malignancies and brain metastases.
Collapse
Affiliation(s)
- Scott Schoen
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - M. Sait Kilinc
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Hohyun Lee
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Yutong Guo
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - F. Levent Degertekin
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Graeme F. Woodworth
- Department of Neurosurgery, University of Maryland School of Medicine, Baltimore, MD 21201, USA,Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, College Park, MD 20742, USA,Fischell Department of Bioengineering A. James Clarke School of Engineering, University of Maryland
| | - Costas Arvanitis
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA,Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
| |
Collapse
|
11
|
Jing B, Lindsey BD. Effect of Skull Porous Trabecular Structure on Transcranial Ultrasound Imaging in the Presence of Elastic Wave Mode Conversion at Varying Incidence Angle. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2734-2748. [PMID: 34140169 DOI: 10.1016/j.ultrasmedbio.2021.05.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Revised: 05/04/2021] [Accepted: 05/07/2021] [Indexed: 06/12/2023]
Abstract
With the advancement of aberration correction techniques, transcranial ultrasound imaging has exhibited great potential in applications such as imaging neurological function and guiding therapeutic ultrasound. However, the feasibility of transcranial imaging varies among individuals because of the differences in skull acoustic properties. To better understand the fundamental mechanisms underlying the variation in imaging performance, the effect of the structure of the porous trabecular bone on transcranial imaging performance (i.e., target localization errors and resolution) was investigated for the first time through the use of elastic wave simulations and experiments. Simulation studies using high-resolution computed tomography data from ex vivo skull samples revealed that imaging at large incidence angles reduced the target localization error for skulls having low porosity; however, as skull porosity increased, large angles of incidence resulted in degradation of resolution and increased target localization errors. Experimental results indicate that imaging at normal incidence introduced a localization error of 1.85 ± 0.10 mm, while imaging at a large incidence angle (40°) resulted in an increased localization error of 6.54 ± 1.33 mm and caused a single point target to no longer appear as a single, coherent target in the resulting image, which is consistent with simulation results. This first investigation of the effects of skull microstructure on transcranial ultrasound imaging indicates that imaging performance is highly dependent on the porosity of the skull, particularly at non-normal angles of incidence.
Collapse
Affiliation(s)
- Bowen Jing
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA
| | - Brooks D Lindsey
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA; School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.
| |
Collapse
|
12
|
Top CB. A Generalized Split-Step Angular Spectrum Method for Efficient Simulation of Wave Propagation in Heterogeneous Media. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2687-2696. [PMID: 33891551 DOI: 10.1109/tuffc.2021.3075367] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Angular spectrum (AS) methods enable efficient calculation of wave propagation from one plane to another inside homogeneous media. For wave propagation in heterogeneous media such as biological tissues, AS methods cannot be applied directly. Split-stepping techniques decompose the heterogeneous domain into homogeneous and perturbation parts, and provide a solution for forward wave propagation by propagating the incident wave in both frequency-space and frequency-wavenumber domains. Recently, a split-step hybrid angular spectrum (HAS) method was proposed for plane wave propagation of focused ultrasound beams. In this study, we extend these methods to enable simulation of acoustic pressure field for an arbitrary source distribution, by decomposing the source and reflection spectra into orthogonal propagation direction components, propagating each component separately, and summing all components to get the total field. We show that our method can efficiently simulate the pressure field of arbitrary sources in heterogeneous media. The accuracy of the method was analyzed comparing the resultant pressure field with pseudospectral time domain (PSTD) solution for breast tomography and hemispherical transcranial-focused ultrasound simulation models. Eighty times acceleration was achieved for a 3-D breast simulation model compared to PSTD solution with 0.005 normalized root mean-squared difference (NRMSD) between two solutions. For the hemispherical phased array, aberrations due to skull were accurately calculated in a single simulation run as evidenced by the resultant-focused ultrasound beam simulations, which had 0.001 NRMSD with 40 times acceleration factor compared to the PSTD method.
Collapse
|
13
|
Li M, Gu J, Vu T, Sankin G, Zhong P, Yao J, Jing Y. Time-Resolved Passive Cavitation Mapping Using the Transient Angular Spectrum Approach. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2361-2369. [PMID: 33635787 PMCID: PMC8269954 DOI: 10.1109/tuffc.2021.3062357] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Passive cavitation mapping (PCM), which generates images using bubble acoustic emission signals, has been increasingly used for monitoring and guiding focused ultrasound surgery (FUS). PCM can be used as an adjunct to magnetic resonance imaging to provide crucial information on the safety and efficacy of FUS. The most widely used algorithm for PCM is delay-and-sum (DAS). One of the major limitations of DAS is its suboptimal computational efficiency. Although frequency-domain DAS can partially resolve this issue, such an algorithm is not suitable for imaging the evolution of bubble activity in real time and for cases in which cavitation events occur asynchronously. This study investigates a transient angular spectrum (AS) approach for PCM. The working principle of this approach is to backpropagate the received signal to the domain of interest and reconstruct the spatial-temporal wavefield encoded with the bubble location and collapse time. The transient AS approach is validated using an in silico model and water bath experiments. It is found that the transient AS approach yields similar results to DAS, but it is one order of magnitude faster. The results obtained by this study suggest that the transient AS approach is promising for fast and accurate PCM.
Collapse
|
14
|
Bancel T, Houdouin A, Annic P, Rachmilevitch I, Shapira Y, Tanter M, Aubry JF. Comparison Between Ray-Tracing and Full-Wave Simulation for Transcranial Ultrasound Focusing on a Clinical System Using the Transfer Matrix Formalism. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2554-2565. [PMID: 33651688 DOI: 10.1109/tuffc.2021.3063055] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Only one high-intensity focused ultrasound device has been clinically approved for transcranial brain surgery at the time of writing. The device operates within 650 and 720 kHz and corrects the phase distortions induced by the skull of each patient using a multielement phased array. Phase correction is estimated adaptively using a proprietary algorithm based on computed-tomography (CT) images of the patient's skull. In this article, we assess the performance of the phase correction computed by the clinical device and compare it to: 1) the correction obtained with a previously validated full-wave simulation algorithm using an open-source pseudo-spectral toolbox and 2) a hydrophone-based correction performed invasively to measure the aberrations induced by the skull at 650 kHz. For the full-wave simulation, three different mappings between CT Hounsfield units and the longitudinal speed of sound inside the skull were tested. All methods are compared with the exact same setup due to transfer matrices acquired with the clinical system for N = 5 skulls and T = 2 different targets for each skull. We show that the clinical ray-tracing software and the full-wave simulation restore, respectively, 84% ± 5% and 86% ± 5% of the pressure obtained with hydrophone-based correction for targets located in central brain regions. On the second target (off-center), we also report that the performance of both algorithms degrades when the average incident angles of the acoustic beam at the skull surface increase. When incident angles are higher than 20°, the restored pressure drops below 75% of the pressure restored with hydrophone-based correction.
Collapse
|
15
|
Guo Y, Lee H, Fang Z, Velalopoulou A, Kim J, Thomas MB, Liu J, Abramowitz RG, Kim Y, Coskun AF, Krummel DP, Sengupta S, MacDonald TJ, Arvanitis C. Single-cell analysis reveals effective siRNA delivery in brain tumors with microbubble-enhanced ultrasound and cationic nanoparticles. SCIENCE ADVANCES 2021; 7:7/18/eabf7390. [PMID: 33931452 PMCID: PMC8087400 DOI: 10.1126/sciadv.abf7390] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 03/12/2021] [Indexed: 05/08/2023]
Abstract
RNA-based therapies offer unique advantages for treating brain tumors. However, tumor penetrance and uptake are hampered by RNA therapeutic size, charge, and need to be "packaged" in large carriers to improve bioavailability. Here, we have examined delivery of siRNA, packaged in 50-nm cationic lipid-polymer hybrid nanoparticles (LPHs:siRNA), combined with microbubble-enhanced focused ultrasound (MB-FUS) in pediatric and adult preclinical brain tumor models. Using single-cell image analysis, we show that MB-FUS in combination with LPHs:siRNA leads to more than 10-fold improvement in siRNA delivery into brain tumor microenvironments of the two models. MB-FUS delivery of Smoothened (SMO) targeting siRNAs reduces SMO protein production and markedly increases tumor cell death in the SMO-activated medulloblastoma model. Moreover, our analysis reveals that MB-FUS and nanoparticle properties can be optimized to maximize delivery in the brain tumor microenvironment, thereby serving as a platform for developing next-generation tunable delivery systems for RNA-based therapy in brain tumors.
Collapse
Affiliation(s)
- Yutong Guo
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Hohyun Lee
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Zhou Fang
- Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Anastasia Velalopoulou
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Jinhwan Kim
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Midhun Ben Thomas
- Department of Neurology, Emory University School of Medicine, Atlanta, GA, USA
| | - Jingbo Liu
- Department of Pediatrics, Aflac Cancer and Blood, Emory University School of Medicine, Atlanta, GA, USA
| | - Ryan G Abramowitz
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - YongTae Kim
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
- Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Ahmet F Coskun
- Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Daniel Pomeranz Krummel
- Department of Neurology and Rehabilitation Medicine, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Soma Sengupta
- Department of Neurology and Rehabilitation Medicine, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Tobey J MacDonald
- Department of Pediatrics, Aflac Cancer and Blood, Emory University School of Medicine, Atlanta, GA, USA
| | - Costas Arvanitis
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
- Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| |
Collapse
|
16
|
Jiang C, Li Y, Xu K, Ta D. Full-Matrix Phase Shift Migration Method for Transcranial Ultrasonic Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:72-83. [PMID: 32795967 DOI: 10.1109/tuffc.2020.3016382] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A spectrum-domain method, called full-matrix phase shift migration (FM-PSM), is presented for transcranial ultrasound phase correction and imaging with ideal synthetic aperture focusing technology. The simulated data obtained using the pseudospectral time-domain method are used to evaluate the feasibility of the method. The experimental data measured from a 3-D printed skull phantom are used to evaluate the algorithm performance in terms of resolution, contrast-to-noise ratio (CNR), and eccentricity comparing with the classical ray-tracing delay and sum (DAS) method. In wire imaging experiment, FM-PSM has a lateral resolution of 0.22 mm and ray-tracing DAS has a lateral resolution of 0.24 mm measured at -6-dB drop using a transducer with a center frequency of 6.25 MHz. In cylinder imaging experiment, FM-PSM has a CNR of 2.14 and ray-tracing DAS has a CNR of 1.82, which illustrates about 17% improvement. For a J -element array and an output image with pixels M ×N (lateral × axial), the computational cost of the DAS is of O(J ×M2×N2) ; on the contrary, it reduces to O(J ×M ×N2) with the proposed FM-PSM. The results suggest that FM-PSM is an efficiency method for transcranial ultrasonic imaging.
Collapse
|
17
|
Schoen S, Arvanitis CD. Acoustic source localization with the angular spectrum approach in continuously stratified media. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:EL333. [PMID: 33138472 PMCID: PMC7567611 DOI: 10.1121/10.0002095] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 09/09/2020] [Accepted: 09/11/2020] [Indexed: 06/08/2023]
Abstract
The angular spectrum approach (ASA)-a frequency domain method to calculate the acoustic field-enables highly efficient passive source localization and modeling forward propagation in homogeneous media. If the medium is continuously stratified, a first-order analytical solution may be obtained for the field at arbitrary depth. Simulations show that the proposed stratified ASA solution enables accurate source localization as compared to the uncorrected ASA (error from 1.2 ± 0.3 to 0.49 ± 0.3 wavelengths) at scalings relevant to biomedical, underwater, and atmospheric acoustic applications, and requiring milliseconds on nonspecialized hardware. The results suggest the proposed correction enables efficient and accurate localization in stratified environments.
Collapse
Affiliation(s)
- Scott Schoen
- Mechanical Engineering, Georgia Tech, Atlanta, Georgia 30332, ,
| | | |
Collapse
|