1
|
Naseri S, Samaram H, Naghavi N, Rassouli MB, Mousavinezhad M. Types of Short-Duration Electrical Stimulation-Induced Efficiency in the Axonal Regeneration and Recovery: Comparative in Vivo Study in Rat Model of Repaired Sciatic Nerve and its Tibial Branch after Transection Injury. Neurochem Res 2024; 49:2469-2479. [PMID: 38856888 DOI: 10.1007/s11064-024-04154-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 04/25/2024] [Accepted: 05/16/2024] [Indexed: 06/11/2024]
Abstract
The restoration of adequate function and sensation in nerves following an injury is often insufficient. Electrical stimulation (ES) applied during nerve repair can promote axon regeneration, which may enhance the likelihood of successful functional recovery. However, increasing operation time and complexity are associated with limited clinical use of ES. This study aims to better assess whether short-duration ES types (voltage mode vs. current mode) are able to produce enhanced regenerative activity following peripheral nerve repair in rat models. Wistar rats were randomly divided into 3 groups: no ES (control), 30-minute ES with a current pulse, and 30-minute ES with a voltage pulse. All groups underwent sciatic nerve transection and repair using a silicone tube to bridge the 6-mm gap between the stumps. In the 2 groups other than the control, ES was applied after the surgical repair. Outcomes were evaluated using electrophysiology, histology, and serial walking track analysis. Biweekly walking tracks test over 12 weeks revealed that subjects that underwent ES experienced more rapid functional improvement than subjects that underwent repair alone. Electrophysiological analysis of the newly intratubular sciatic nerve at week 12 revealed strong motor function recovery in rats that underwent 30-minute ES. Histologic analysis of the sciatic nerve and its tibial branch at 12 weeks demonstrated robust axon regrowth in all groups. Both types of short-duration ES applied during nerve repair can promote axon regrowth and enhance the chances of successful functional recovery.
Collapse
Affiliation(s)
- Sareh Naseri
- Electrical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, Azadi Square, Mashhad, Razavi Khorasan Province, 9177948374, Iran
| | - Hosein Samaram
- Electrical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, Azadi Square, Mashhad, Razavi Khorasan Province, 9177948374, Iran
| | - Nadia Naghavi
- Electrical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, Azadi Square, Mashhad, Razavi Khorasan Province, 9177948374, Iran.
| | | | - Maryam Mousavinezhad
- Biology Department, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad, Iran
| |
Collapse
|
2
|
Maeng WY, Tseng WL, Li S, Koo J, Hsueh YY. Electroceuticals for peripheral nerve regeneration. Biofabrication 2022; 14. [PMID: 35995036 PMCID: PMC10109522 DOI: 10.1088/1758-5090/ac8baa] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 08/22/2022] [Indexed: 11/12/2022]
Abstract
Electroceuticals provide promising opportunities for peripheral nerve regeneration, in terms of modulating the extensive endogenous tissue repair mechanisms between neural cell body, axons and target muscles. However, great challenges remain to deliver effective and controllable electroceuticals via bioelectronic implantable device. In this review, the modern fabrication methods of bioelectronic conduit for bridging critical nerve gaps after nerve injury are summarized, with regard to conductive materials and core manufacturing process. In addition, to deliver versatile electrical stimulation, the integration of implantable bioelectronic device is discussed, including wireless energy harvesters, actuators and sensors. Moreover, a comprehensive insight of beneficial mechanisms is presented, including up-to-date in vitro, in vivo and clinical evidence. By integrating conductive biomaterials, 3D engineering manufacturing process and bioelectronic platform to deliver versatile electroceuticals, the modern biofabrication enables comprehensive biomimetic therapies for neural tissue engineering and regeneration in the new era.
Collapse
Affiliation(s)
- Woo-Youl Maeng
- Bio-Medical Engineering, Korea University, B156, B, Hana Science Hall, 145, Anam-ro, Seongbuk-gu, Seoul, Seongbuk-gu, Seoul, 02841, Korea (the Republic of)
| | - Wan Ling Tseng
- Department of Surgery, National Cheng Kung University College of Medicine, No.138, Sheng-Li road, Tainan, 701, TAIWAN
| | - Song Li
- Department of Bioengineering, University of California Los Angeles, 5121 Eng V, Los Angeles, California, 90095, UNITED STATES
| | - Jahyun Koo
- Biomedical Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, 02841, Korea (the Republic of)
| | - Yuan-Yu Hsueh
- Department of Surgery, National Cheng Kung University College of Medicine, No.138, Sheng-Li road, Tainan, 701, TAIWAN
| |
Collapse
|
3
|
Wang Y, Wang PM, Larauche M, Mulugeta M, Liu W. Bio-impedance method to monitor colon motility response to direct distal colon stimulation in anesthetized pigs. Sci Rep 2022; 12:13761. [PMID: 35961998 PMCID: PMC9374686 DOI: 10.1038/s41598-022-17549-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 07/27/2022] [Indexed: 11/09/2022] Open
Abstract
Electrical stimulation has been demonstrated as an alternative approach to alleviate intractable colonic motor disorders, whose effectiveness can be evaluated through colonic motility assessment. Various methods have been proposed to monitor the colonic motility and while each has contributed towards better understanding of colon motility, a significant limitation has been the spatial and temporal low-resolution colon motility data acquisition and analysis. This paper presents the study of employing bio-impedance characterization to monitor colonic motor activity. Direct distal colon stimulation was undertaken in anesthetized pigs to validate the bio-impedance scheme simultaneous with luminal manometry monitoring. The results indicated that the significant decreases of bio-impedance corresponded to strong colonic contraction in response to the electrical stimulation in the distal colon. The magnitude/power of the dominant frequencies of phasic colonic contractions identified at baseline (in the range 2-3 cycles per minute (cpm)) were increased after the stimulation. In addition, positive correlations have been found between bio-impedance and manometry. The proposed bio-impedance-based method can be a viable candidate for monitoring colonic motor pattern with high spatial and temporal resolution. The presented technique can be integrated into a closed-loop therapeutic device in order to optimize its stimulation protocol in real-time.
Collapse
Affiliation(s)
- Yushan Wang
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Po-Min Wang
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Muriel Larauche
- Vatche and Tamar Manoukian Division of Digestive Diseases, Department of Medicine, David Geffen School of Medicine, CURE: Digestive Diseases Research Core Center (DDRCC), Center for Neurobiology of Stress and Resilience (CNSR), University of California, Los Angeles, Los Angeles, CA, USA.,VA Greater Los Angeles Healthcare System, Los Angeles, CA, USA
| | - Million Mulugeta
- Vatche and Tamar Manoukian Division of Digestive Diseases, Department of Medicine, David Geffen School of Medicine, CURE: Digestive Diseases Research Core Center (DDRCC), Center for Neurobiology of Stress and Resilience (CNSR), University of California, Los Angeles, Los Angeles, CA, USA. .,VA Greater Los Angeles Healthcare System, Los Angeles, CA, USA.
| | - Wentai Liu
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, USA. .,Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA. .,California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA, USA. .,Brain Research Institute, University of California, Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
4
|
Designing and Implementing an Implantable Wireless Micromanometer System for Real-Time Bladder Pressure Monitoring: A Preliminary Study. SENSORS 2020; 20:s20164610. [PMID: 32824415 PMCID: PMC7472397 DOI: 10.3390/s20164610] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 08/12/2020] [Accepted: 08/14/2020] [Indexed: 11/17/2022]
Abstract
Many mini-implantable devices have been developed and fabricated for diagnostic and treatment purposes. Wireless implantable biomicrosystems provide a desirable approach for long-term physiological signal monitoring. In this study, we implemented a wireless implantable biomicrosystem for bladder-cavity pressure measurements in a freely moving rabbit. To manage the power more effectively, a magnetic reed switch was applied to turn on/off the implantable module using a neodymium-iron-boron (NdFeB) magnet. The measured bladder pressure signal was wirelessly transmitted from the implantable module to a host unit. Our results indicated that the implantable biomicrosystem exhibited satisfactory performance and safety, as evidenced by an error percentage of less than ±1% for pressure measurements and less than 2 °C of a temperature rise under normal operation. The wireless biomicrosystem was implanted into the bladder cavity of a rabbit. Bladder pressure was simultaneously measured by both the biomicrosystem and conventional cystometry in the animal. The two signals were similar during the voiding phase, with a correlation coefficient of 0.885. Additionally, the biomicrosystem coated with polydimethylsiloxane in this study showed no cytotoxicity, which confirmed its biocompatibility. In conclusion, we demonstrated a good biocompatible wireless biomicrosystem which showed good reproducibility with respect to pressure monitoring by conventional cystometry. Further studies are needed to confirm the results of this preliminary feasibility study for actual clinical applications.
Collapse
|
5
|
Restoration of Neurological Function Following Peripheral Nerve Trauma. Int J Mol Sci 2020; 21:ijms21051808. [PMID: 32155716 PMCID: PMC7084579 DOI: 10.3390/ijms21051808] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 02/25/2020] [Accepted: 03/03/2020] [Indexed: 12/12/2022] Open
Abstract
Following peripheral nerve trauma that damages a length of the nerve, recovery of function is generally limited. This is because no material tested for bridging nerve gaps promotes good axon regeneration across the gap under conditions associated with common nerve traumas. While many materials have been tested, sensory nerve grafts remain the clinical “gold standard” technique. This is despite the significant limitations in the conditions under which they restore function. Thus, they induce reliable and good recovery only for patients < 25 years old, when gaps are <2 cm in length, and when repairs are performed <2–3 months post trauma. Repairs performed when these values are larger result in a precipitous decrease in neurological recovery. Further, when patients have more than one parameter larger than these values, there is normally no functional recovery. Clinically, there has been little progress in developing new techniques that increase the level of functional recovery following peripheral nerve injury. This paper examines the efficacies and limitations of sensory nerve grafts and various other techniques used to induce functional neurological recovery, and how these might be improved to induce more extensive functional recovery. It also discusses preliminary data from the clinical application of a novel technique that restores neurological function across long nerve gaps, when repairs are performed at long times post-trauma, and in older patients, even under all three of these conditions. Thus, it appears that function can be restored under conditions where sensory nerve grafts are not effective.
Collapse
|
6
|
Multifunctional hydrogel coatings on the surface of neural cuff electrode for improving electrode-nerve tissue interfaces. Acta Biomater 2016; 39:25-33. [PMID: 27163406 DOI: 10.1016/j.actbio.2016.05.009] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Revised: 03/18/2016] [Accepted: 05/03/2016] [Indexed: 01/12/2023]
Abstract
UNLABELLED Recently, implantable neural electrodes have been developed for recording and stimulation of the nervous system. However, when the electrode is implanted onto the nerve trunk, the rigid polyimide has a risk of damaging the nerve and can also cause inflammation due to a mechanical mismatch between the stiff polyimide and the soft biological tissue. These processes can interrupt the transmission of nerve signaling. In this paper, we have developed a nerve electrode coated with PEG hydrogel that contains poly(lactic-co-glycolic) acid (PLGA) microspheres (MS) loaded with anti-inflammatory cyclosporin A (CsA). Micro-wells were introduced onto the electrode in order to increase their surface area. This allows for loading a high-dose of the drug. Additionally, chemically treating the surface with aminopropylmethacrylamide can improve the adhesive interface between the electrode and the hydrogel. The surface of the micro-well cuff electrode (MCE) coated with polyethylene glycol (PEG) hydrogel and drug loaded PLGA microspheres (MS) were characterized by SEM and optical microscopy. Additionally, the conductive polymers, poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT/PSS), were formed on the hydrogel layer for improving the nerve signal quality, and then characterized for their electrochemical properties. The loading efficiencies and release profiles were investigated by High Performance Liquid Chromatography (HPLC). The drug loaded electrode resulted in a sustained release of CsA. Moreover, the surface coated electrode with PEG hydrogel and CsA loaded MP showed a significantly decreased fibrous tissue deposition and increased axonal density in animal tests. We expect that the developed nerve electrode will minimize the tissue damage during regeneration of the nervous system. STATEMENT OF SIGNIFICANCE The nerve electrodes are used for interfacing with the central nervous system (CNS) or with the peripheral nervous system (PNS). The interface electrodes should facilitate a closed interconnection with the nerve tissue and provide for selective stimulation and recording from multiple, independent, neurons of the neural system. In this case, an extraneural electrodes such as cuff and perineural electrodes are widely investigated because they can completely cover the nerve trunk and provide for a wide interface area. In this study, we have designed and prepared a functionalized nerve cuff electrode coated with PEG hydrogel containing Poly lactic-co-glycol acid (PLGA) microspheres (MS) loaded with cyclosporine A (CsA). To our knowledge, our findings suggest that surface coating a soft-hydrogel along with an anti-inflammatory drug loaded MS can be a useful strategy for improving the long-term biocompatibility of electrodes.
Collapse
|
7
|
Lo YK, Chang CW, Liu W. Bio-impedance characterization technique with implantable neural stimulator using biphasic current stimulus. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2014:474-7. [PMID: 25569999 DOI: 10.1109/embc.2014.6943631] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Knowledge of the bio-impedance and its equivalent circuit model at the electrode-electrolyte/tissue interface is important in the application of functional electrical stimulation. Impedance can be used as a merit to evaluate the proximity between electrodes and targeted tissues. Understanding the equivalent circuit parameters of the electrode can further be leveraged to set a safe boundary for stimulus parameters in order not to exceed the water window of electrodes. In this paper, we present an impedance characterization technique and implement a proof-of-concept system using an implantable neural stimulator and an off-the-shelf microcontroller. The proposed technique yields the parameters of the equivalent circuit of an electrode through large signal analysis by injecting a single low-intensity biphasic current stimulus with deliberately inserted inter-pulse delay and by acquiring the transient electrode voltage at three well-specified timings. Using low-intensity stimulus allows the derivation of electrode double layer capacitance since capacitive charge-injection dominates when electrode overpotential is small. Insertion of the inter-pulse delay creates a controlled discharge time to estimate the Faradic resistance. The proposed method has been validated by measuring the impedance of a) an emulated Randles cells made of discrete circuit components and b) a custom-made platinum electrode array in-vitro, and comparing estimated parameters with the results derived from an impedance analyzer. The proposed technique can be integrated into implantable or commercial neural stimulator system at low extra power consumption, low extra-hardware cost, and light computation.
Collapse
|
8
|
Hsieh TH, Lin YT, Chen SC, Peng CW. Chronic pudendal neuromodulation using an implantable microstimulator improves voiding function in diabetic rats. J Neural Eng 2016; 13:046001. [PMID: 27187108 DOI: 10.1088/1741-2560/13/4/046001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Objective Few studies have investigated the feasibility of using chronic pudendal neuromodulation for improving voiding function in patients with diabetes who are also experiencing urinary retention. The present study investigated the effects of chronic electrical stimulation (ES) of the sensory branch of the pudendal nerve on voiding function in diabetic rats. Approach A custom-made implantable microstimulation system was designed and manufactured for chronic implantation in normal control (NC) and diabetic rats. After three or six weeks of pudendal neuromodulation, the intravesical pressure, external urethral sphincter electromyograms (EUS-EMGs), and urine flow rate (UFR) of all rats were simultaneously recorded to assess the effects of chronic pudendal ES on voiding function. Morphological changes in pudendal axons were assessed through hematoxylin and eosin (H&E) staining. Significance This study demonstrated the feasibility of using chronic pudendal neuromodulation for improving voiding function in diabetic rats. These results may facilitate the development of an advanced neural prosthesis for restoring bladder function in clinical settings.
Collapse
Affiliation(s)
- Tsung-Hsun Hsieh
- Graduate Institute of Neural Regenerative Medicine, Taipei Medical University, Taipei, Taiwan. Department of Physical Therapy and Graduate Institute of Rehabilitation Science, College of Medicine and Healthy Aging Research Center, Chang Gung University, Taoyuan, Taiwan. Neuroscience Research Center, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan
| | | | | | | |
Collapse
|
9
|
A current-excited triple-time-voltage oversampling method for bio-impedance model for cost-efficient circuit system. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:1037-40. [PMID: 26736442 DOI: 10.1109/embc.2015.7318542] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This paper presents a mathematic method and a cost-efficient circuit to measure the value of each component of the bio-impedance model at electrode-electrolyte interface. The proposed current excited triple-time-voltage oversampling (TTVO) method deduces the component values by solving triple simultaneous electric equation (TSEE) at different time nodes during a current excitation, which are the voltage functions of time. The proposed triple simultaneous electric equations (TSEEs) allows random selections of the time nodes, hence numerous solutions can be obtained during a single current excitation. Following that, the oversampling approach is engaged by averaging all solutions of multiple TSEEs acquired after a single current excitation, which increases the practical measurement accuracy through the improvement of the signal-to-noise ratio (SNR). In addition, a print circuit board (PCB) that consists a switched current exciter and an analog-to-digital converter (ADC) is designed for signal acquisition. This presents a great cost reduction when compared against other instrument-based measurement data reported [1]. Through testing, the measured values of this work is proven to be in superb agreements on the true component values of the electrode-electrolyte interface model. This work is most suited and also useful for biological and biomedical applications, to perform tasks such as stimulations, recordings, impedance characterizations, etc.
Collapse
|
10
|
An Integrated Chip High-Voltage Power Receiver for Wireless Biomedical Implants. ENERGIES 2015. [DOI: 10.3390/en8065467] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
11
|
Sakuma M, Minev IR, Gribi S, Singh B, Woolf CJ, Lacour SP. Chronic Electrical Nerve Stimulation as a Therapeutic Intervention for Peripheral Nerve Repair. Bioelectron Med 2015. [DOI: 10.15424/bioelectronmed.2015.00005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
12
|
Martin C, Dejardin T, Hart A, Riehle MO, Cumming DRS. Directed nerve regeneration enabled by wirelessly powered electrodes printed on a biodegradable polymer. Adv Healthc Mater 2014; 3:1001-6. [PMID: 24376117 DOI: 10.1002/adhm.201300481] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2013] [Revised: 10/16/2013] [Indexed: 01/09/2023]
Abstract
Wirelessly directed nerve regeneration: inductively powered electrical stimulation circuits on the biodegradable polymer polycaprolactone demonstrate directed regeneration of sensory neurons from a dorsal root ganglion. These circuits, produced using a unique transfer printing process, illustrate progress towards the use of electrical stimulation systems on biodegradable materials to improve peripheral nerve repair functional outcomes.
Collapse
Affiliation(s)
- Christopher Martin
- Electronics Design Centre, School of Engineering; University of Glasgow; G12 8LT UK
| | - Théophile Dejardin
- Centre for Cell Engineering; Joseph Black Building, University of Glasgow; G12 8QQ UK
| | - Andrew Hart
- Centre for Cell Engineering; Joseph Black Building, University of Glasgow; G12 8QQ UK
| | - Mathis O. Riehle
- Centre for Cell Engineering; Joseph Black Building, University of Glasgow; G12 8QQ UK
| | - David R. S. Cumming
- Electronics Design Centre, School of Engineering; University of Glasgow; G12 8LT UK
| |
Collapse
|
13
|
Plachta DTT, Gierthmuehlen M, Cota O, Espinosa N, Boeser F, Herrera TC, Stieglitz T, Zentner J. Blood pressure control with selective vagal nerve stimulation and minimal side effects. J Neural Eng 2014; 11:036011. [PMID: 24809832 DOI: 10.1088/1741-2560/11/3/036011] [Citation(s) in RCA: 105] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Hypertension is the largest threat to patient health and a burden to health care systems. Despite various options, 30% of patients do not respond sufficiently to medical treatment. Mechanoreceptors in the aortic arch relay blood pressure (BP) levels through vagal nerve (VN) fibers to the brainstem and trigger the baroreflex, lowering the BP. Selective electrical stimulation of these nerve fibers reduced BP in rats. However, there is no technique described to localize and stimulate these fibers inside the VN without inadvertent stimulation of non-baroreceptive fibers causing side effects like bradycardia and bradypnea. APPROACH We present a novel method for selective VN stimulation to reduce BP without the aforementioned side effects. Baroreceptor compound activity of rat VN (n = 5) was localized using a multichannel cuff electrode, true tripolar recording and a coherent averaging algorithm triggered by BP or electrocardiogram. MAIN RESULTS Tripolar stimulation over electrodes near the barofibers reduced the BP without triggering significant bradycardia and bradypnea. The BP drop was adjusted to 60% of the initial value by varying the stimulation pulse width and duration, and lasted up to five times longer than the stimulation. SIGNIFICANCE The presented method is robust to impedance changes, independent of the electrode's relative position, does not compromise the nerve and can run on implantable, ultra-low power signal processors.
Collapse
Affiliation(s)
- Dennis T T Plachta
- Department of Microsystems Engineering (IMTEK), Laboratory for Biomedical Microtechnology, University of Freiburg, Georges-Koehler-Allee 102, D-79110 Freiburg, Germany
| | | | | | | | | | | | | | | |
Collapse
|