1
|
Development of an ultrasound guided focused ultrasound system for 3D volumetric low energy nanodroplet-mediated histotripsy. Sci Rep 2022; 12:20664. [PMID: 36450815 PMCID: PMC9712369 DOI: 10.1038/s41598-022-25129-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 11/24/2022] [Indexed: 12/03/2022] Open
Abstract
Low pressure histotripsy is likely to facilitate current treatments that require extremely high pressures. An ultrasound guided focused ultrasound system was designed to accommodate a rotating imaging transducer within a low frequency therapeutic transducer that operates at a center frequency of 105 kHz. The implementation of this integrated system provides real-time therapeutic and volumetric imaging functions, that are used here for low-cost, low-energy 3D volumetric ultrasound histotripsy using nanodroplets. A two-step approach for low pressure histotripsy is implemented with this dual-array. Vaporization of nanodroplets into gaseous microbubbles was performed via the 1D rotating imaging probe. The therapeutic transducer is then used to detonate the vaporized nanodroplets and trigger potent mechanical effects in the surrounding tissue. Rotating the imaging transducer creates a circular vaporized nanodroplet shape which generates a round lesion upon detonation. This contrasts with the elongated lesion formed when using a standard 1D imaging transducer for nanodroplet activation. Optimization experiments show that maximal nanodroplet activation can be achieved with a 2-cycle excitation pulse at a center frequency of 3.5 MHz, and a peak negative pressure of 3.4 MPa (a mechanical index of 1.84). Vaporized nanodroplet detonation was achieved by applying a low frequency treatment at a center frequency of 105 kHz and mechanical index of 0.9. In ex-vivo samples, the rotated nanodroplet activation method yielded the largest lesion area, with a mean of 4.7 ± 0.5 mm2, and a rounded shape. In comparison, standard fixed transducer nanodroplet activation resulted in an average lesion area of 2.6 ± 0.4 mm2, and an elongated shape. This hybrid system enables to achieve volumetric low energy histotripsy, and thus facilitates the creation of precise, large-volume mechanical lesions in tissues, while reducing the pressure threshold required for standard histotripsy by over an order of magnitude.
Collapse
|
2
|
Latham K, Samson C, Woodacre J, Brown J. A 30-MHz, 3-D Imaging, Forward-Looking Miniature Endoscope Based on a 128-Element Relaxor Array. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:1261-1271. [PMID: 32997625 DOI: 10.1109/tuffc.2020.3027907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
This work describes the design, fabrication, and characterization of a 128-element crossed electrode array in a miniature endoscopic form factor for real-time 3-D imaging. Crossed electrode arrays address some of the key challenges surrounding probe fabrication for 3-D ultrasound imaging by reducing the number of elements required (2N compared with N2). However, there remain practical challenges in packaging a high-frequency crossed electrode array into an endoscopic form factor. A process has been developed that uses a thinly diced strip of flex circuit to bring the back-side connections to common bond surface, which allows the final size of the endoscope to measure only [Formula: see text] mm. An electrostrictive ceramic composite design was developed for the crossed electrode array. A laser dicing system was used to cut the 1-3 composite as well as etch the array electrode pattern. A single quarter wavelength Parylene matching layer made was vacuum deposited to finish the array. The electrical impedance magnitude of array elements on resonance was measured to be 49 Ω with a phase angle of -55.5°. The finished array elements produced pulses with -6-dB two-way bandwidth of 60% with a 34-MHz center frequency. The average measured electrical crosstalk on the nearest neighboring element and next to nearest neighboring element was -37 and -29 dB, respectively. One- and two-way pulse measurements were completed to confirm the pulse polarity and fast switching speed. Preliminary 3-D images were generated of a wire phantom using the previously described simultaneous azimuth and Fresnel elevation (SAFE) compounding imaging technique.
Collapse
|
3
|
Priester AM, Natarajan S, Culjat MO. Robotic ultrasound systems in medicine. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:507-523. [PMID: 23475917 DOI: 10.1109/tuffc.2013.2593] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Robots ultrasound (RUS) can be defined as the combination of ultrasound imaging with a robotic system in medical interventions. With their potential for high precision, dexterity, and repeatability, robots are often uniquely suited for ultrasound integration. Although the field is relatively young, it has already generated a multitude of robotic systems for application in dozens of medical procedures. This paper reviews the robotic ultrasound systems that have been developed over the past two decades and describes their potential impact on modern medicine. The RUS projects reviewed include extracorporeal devices, needle guidance systems, and intraoperative systems.
Collapse
Affiliation(s)
- Alan M Priester
- Biomedical Engineering Interdepartmental Program and the Center for Advanced Surgical and Interventional Technology, University of California, Los Angeles, Los Angeles, CA, USA.
| | | | | |
Collapse
|
4
|
Simpson AL, Dumpuri P, Jarnagin WR, Miga MI. Model-Assisted Image-Guided Liver Surgery Using Sparse Intraoperative Data. STUDIES IN MECHANOBIOLOGY, TISSUE ENGINEERING AND BIOMATERIALS 2012. [DOI: 10.1007/8415_2012_117] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
5
|
Moustris GP, Hiridis SC, Deliparaschos KM, Konstantinidis KM. Evolution of autonomous and semi-autonomous robotic surgical systems: a review of the literature. Int J Med Robot 2011; 7:375-92. [DOI: 10.1002/rcs.408] [Citation(s) in RCA: 199] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/12/2011] [Indexed: 12/25/2022]
|
6
|
Liang K, Rogers AJ, Light ED, Von Allmen D, Smith SW. Simulation of autonomous robotic multiple-core biopsy by 3D ultrasound guidance. ULTRASONIC IMAGING 2010; 32:118-127. [PMID: 20687279 PMCID: PMC3018680 DOI: 10.1177/016173461003200205] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
An autonomous multiple-core biopsy system guided by real-time 3D ultrasound and operated by a robotic arm with 6+1 degrees of freedom has been developed. Using a specimen of turkey breast as a tissue phantom, our system was able to first autonomously locate the phantom in the image volume and then perform needle sticks in each of eight sectors in the phantom in a single session, with no human intervention required. Based on the fraction of eight sectors successfully sampled in an experiment of five trials, a success rate of 93% was recorded. This system could have relevance in clinical procedures that involve multiple needle-core sampling such as prostate or breast biopsy.
Collapse
Affiliation(s)
- Kaicheng Liang
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA.
| | | | | | | | | |
Collapse
|
7
|
Liang K, Rogers AJ, Light ED, von Allmen D, Smith SW. Three-dimensional ultrasound guidance of autonomous robotic breast biopsy: feasibility study. ULTRASOUND IN MEDICINE & BIOLOGY 2010; 36:173-177. [PMID: 19900753 PMCID: PMC2800959 DOI: 10.1016/j.ultrasmedbio.2009.08.014] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2009] [Revised: 07/13/2009] [Accepted: 08/28/2009] [Indexed: 05/26/2023]
Abstract
Feasibility studies of autonomous robot biopsies in tissue have been conducted using real-time three-dimensional (3-D) ultrasound combined with simple thresholding algorithms. The robot first autonomously processed 3-D image volumes received from the ultrasound scanner to locate a metal rod target embedded in turkey breast tissue simulating a calcification, and in a separate experiment, the center of a water-filled void in the breast tissue simulating a cyst. In both experiments the robot then directed a needle to the desired target, with no user input required. Separate needle-touch experiments performed by the image-guided robot in a water tank yielded an rms error of 1.15 mm. (E-mail: kaicheng.liang@duke.edu).
Collapse
Affiliation(s)
- Kaicheng Liang
- Department of Biomedical Engineering, Duke University, Durham, NC, USA.
| | | | | | | | | |
Collapse
|
8
|
Rogers AJ, Light ED, Smith SW. 3-D ultrasound guidance of autonomous robot for location of ferrous shrapnel. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2009; 56:1301-1303. [PMID: 19574140 PMCID: PMC2810201 DOI: 10.1109/tuffc.2009.1185] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Vibrations can be induced in ferromagnetic shrapnel by a variable electromagnet. Real time 3-D color Doppler ultrasound located the induced motion in a needle fragment and determined its 3-D position in the scanner coordinates. This information was used to guide a robot which moved a probe to touch the shrapnel fragment.
Collapse
|
9
|
Herickhoff CD, Light ED, Bing KF, Mukundan S, Grant GA, Wolf PD, Smith SW. Dual-mode intracranial catheter integrating 3D ultrasound imaging and hyperthermia for neuro-oncology: feasibility study. ULTRASONIC IMAGING 2009; 31:81-100. [PMID: 19630251 PMCID: PMC2810199 DOI: 10.1177/016173460903100201] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
In this study, we investigated the feasibility of an intracranial catheter transducer with dual-mode capability of real-time 3D (RT3D) imaging and ultrasound hyperthermia, for application in the visualization and treatment of tumors in the brain. Feasibility is demonstrated in two ways: first by using a 50-element linear array transducer (17 mm x 3.1 mm aperture) operating at 4.4 MHz with our Volumetrics diagnostic scanner and custom, electrical impedance-matching circuits to achieve a temperature rise over 4 degrees C in excised pork muscle, and second, by designing and constructing a 12 Fr, integrated matrix and linear-array catheter transducer prototype for combined RT3D imaging and heating capability. This dual-mode catheter incorporated 153 matrix array elements and 11 linear array elements diced on a 0.2 mm pitch, with a total aperture size of 8.4 mm x 2.3 mm. This 3.64 MHz array achieved a 3.5 degrees C in vitro temperature rise at a 2 cm focal distance in tissue-mimicking material. The dual-mode catheter prototype was compared with a Siemens 10 Fr AcuNav catheter as a gold standard in experiments assessing image quality and therapeutic potential and both probes were used in an in vivo canine brain model to image anatomical structures and color Doppler blood flow and to attempt in vivo heating.
Collapse
MESH Headings
- Animals
- Brain Neoplasms/diagnostic imaging
- Brain Neoplasms/therapy
- Catheterization/instrumentation
- Catheterization/methods
- Dogs
- Equipment Design
- Feasibility Studies
- Hyperthermia, Induced/instrumentation
- Hyperthermia, Induced/methods
- Imaging, Three-Dimensional/instrumentation
- Imaging, Three-Dimensional/methods
- Phantoms, Imaging
- Swine
- Transducers
- Ultrasonography, Doppler, Color/instrumentation
- Ultrasonography, Doppler, Color/methods
- Ultrasonography, Interventional/instrumentation
- Ultrasonography, Interventional/methods
Collapse
Affiliation(s)
- Carl D Herickhoff
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA.
| | | | | | | | | | | | | |
Collapse
|
10
|
Lopata RGP, Hansen HHG, Nillesen MM, Thijssen JM, De Korte CL. Comparison of one-dimensional and two-dimensional least-squares strain estimators for phased array displacement data. ULTRASONIC IMAGING 2009; 31:1-16. [PMID: 19507679 DOI: 10.1177/016173460903100101] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
In this study, the performances of one-dimensional and two-dimensional least-squares strain estimators (LSQSE) are compared. Furthermore, the effects of kernel size are examined using simulated raw frequency data of a widely-adapted hard lesion/soft tissue model. The performances of both methods are assessed in terms of root-mean-squared errors (RMSE), elastographic signal-to-noise ratio (SNRe) and contrast-to-noise ratio (CNRe). RMSE analysis revealed that the 2D LSQSE yields better results for phased array data, especially for larger insonification angles. Using a 2D LSQSE enabled the processing of unfiltered displacement data, in particular for the lateral/horizontal strain components. The SNRe and CNRe analysis showed an improvement in precision and almost no loss in contrast using 2D LSQSE. However, the RMSE images for different kernel sizes revealed that the optimal 2D kernel size depends on the region-of-interest and showed that the LSQ kernel size should be limited to avoid loss in resolution.
Collapse
Affiliation(s)
- Richard G P Lopata
- Clinical Physics Laboratory-833, Department ofPediatrics, Radboud University Nijmegen Medical Centre, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands.
| | | | | | | | | |
Collapse
|
11
|
Whitman J, Fronheiser MP, Smith SW. 3-D ultrasound guidance of surgical robotics using catheter transducers: feasibility study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1143-1145. [PMID: 18519222 DOI: 10.1109/tuffc.2008.766] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The goal of this study was to test the feasibility of using a real-time 3-D (RT3D) ultrasound scanner with matrix array catheter probes to guide a surgical robot. We tested the accuracy of using 3-D catheter transducers with the 3-D measurement software of the scanner to direct automatically a robot arm that touched two needle tips together within a water tank and inside a vascular graft. RMS measurement error ranged from 2.4 to 3.4 mm for two catheter designs.
Collapse
|
12
|
Whitman J, Fronheiser MP, Ivancevich NM, Smith SW. Autonomous surgical robotics using 3-D ultrasound guidance: feasibility study. ULTRASONIC IMAGING 2007; 29:213-219. [PMID: 18481593 DOI: 10.1177/016173460702900402] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The goal of this study was to test the feasibility of using a real-time 3D (RT3D) ultrasound scanner with a transthoracic matrix array transducer probe to guide an autonomous surgical robot. Employing a fiducial alignment mark on the transducer to orient the robot's frame of reference and using simple thresholding algorithms to segment the 3D images, we tested the accuracy of using the scanner to automatically direct a robot arm that touched two needle tips together within a water tank. RMS measurement error was 3.8% or 1.58 mm for an average path length of 41 mm. Using these same techniques, the autonomous robot also performed simulated needle biopsies of a cyst-like lesion in a tissue phantom. This feasibility study shows the potential for 3D ultrasound guidance of an autonomous surgical robot for simple interventional tasks, including lesion biopsy and foreign body removal.
Collapse
Affiliation(s)
- John Whitman
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | | | | | | |
Collapse
|
13
|
Pua EC, Idriss SF, Wolf PD, Smith SW. Real-time three-dimensional transesophageal echocardiography for guiding interventional electrophysiology: feasibility study. ULTRASONIC IMAGING 2007; 29:182-194. [PMID: 18092674 DOI: 10.1177/016173460702900304] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
At present, there are limited methods of acquiring three-dimensional visualization of cardiac structure and function in real-time during interventional electrophysiology procedures. Images acquired for integration of computerized tomography and magnetic resonance imaging with electroanatomic mapping systems are static and are obtained earlier in time. The purpose of this study was to test the feasibility of real-time three-dimensional transesophageal echocardiography for the guidance of interventional electrophysiological studies. A matrix array transducer with 504 channels operating at 5 MHz in a 1 cm diameter steerable esophageal probe was used in conjunction with a scanner capable of real-time 3D scanning of pyramidal volumes from 65 degrees to 120 degrees at rates up to 30 volumes per second. This device has a spatial resolution of approximately 3 mm at 5 cm depth. The authors acquired real-time three-dimensional images of anatomic landmarks of value for electrophysiological procedures in five closed chest canines. Real-time, three-dimensional ultrasound imaging was also used for visualization and guidance of interventional catheter devices within the canine heart. Real-time three-dimensional images of the atria, pulmonary veins, and coronary sinus were acquired. Real-time 3-D color flow Doppler was employed to confirm patency. Multiple image planes of image volumes and rendered views were used to track catheter position and orientation. Images of left veno-atrial junctions have been confirmed by dissection. This study has demonstrated the feasiblity of using real-time three-dimensional transesophageal echocardiography for guiding interventional electrophysiology. The technology has the potential to fill a niche as an adjunct modality for cost-effective real-time interventional guidance and assessment, providing catheter and pacing lead visualization simultaneously with functional volumetric cardiac imaging.
Collapse
Affiliation(s)
- Eric C Pua
- Department of Mechanical Engineering and Materials Science, Duke University, Box 90300, Durham, NC 27708, USA.
| | | | | | | |
Collapse
|
14
|
Pua EC, Qiu Y, Smith SW. Integrated endoscope for real-time 3D ultrasound imaging and hyperthermia: feasibility study. ULTRASONIC IMAGING 2007; 29:1-14. [PMID: 17491295 DOI: 10.1177/016173460702900101] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The goal of this research is to determine the feasibility of using a single endoscopic probe for the combined purpose of real-time 3D (RT3D) ultrasound imaging of a target organ and the delivery of ultrasound therapy to facilitate the absorption of compounds for cancer treatment. Recent research in ultrasound therapy has shown that ultrasound-mediated drug delivery improves absorption of treatments for prostate, cervical and esophageal cancer. The ability to combine ultrasound hyperthermia and 3D imaging could improve visualization and targeting of cancerous tissues. In this study, numerical modeling and experimental measurements were developed to determine the feasibility of combined therapy and imaging with a 1 cm diameter endoscopic RT3D probe with 504 transmitters and 252 receive channels. This device operates at 5 MHz and has a 6.3 mm x 6.3 mm aperture to produce real time 3D pyramidal scans of 60-120 degrees incorporating 64 x 64 = 4096 image lines at 30 volumes/sec interleaved with a 3D steerable therapy beam. A finite-element mesh was constructed with over 128,000 elements in LS-DYNA to simulate the induced temperature rise from our transducer with a 3 cm deep focus in tissue. Quarter-symmetry of the transducer was used to reduce mesh size and computation time. Based on intensity values calculated in Field II using the transducer's array geometry, a minimum I(SPTA) of 3.6 W/cm2 is required from our endoscope probe in order to induce a temperature rise of 4 degrees C within five minutes. Experimental measurements of the array's power output capabilities were conducted using a PVDF hydrophone placed 3 cm away from the face of the transducer in a watertank. Using a PDA14 Signatec data acquisition board to capture full volumes of transmitted ultrasound data, it was determined that the probe can presently maintain intensity values up to 2.4 W/cm2 over indefinite times for therapeutic applications combined with intermittent 3D scanning to maintain targeting. These values were acquired using 8 cycle bursts at a prf of 6 kHz. Ex vivo heating experiments of excised pork tissue yielded a maximum temperature rises of 2.3 degrees C over 5 minutes of ultrasound exposure with an average rise of 1.8 +/- 0.2 degrees C over 5 trials. Modifications to the power supply and transducer array may enable us to reach the higher intensities required to facilitate drug delivery therapy.
Collapse
Affiliation(s)
- Eric C Pua
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA.
| | | | | |
Collapse
|