Chen R, Gao B, Wang X, Zhao H, Wang X, Liu D. Ultrasonographic assessment of renal microcirculation is a new vision for the treatment of intensive care unit associated acute kidney injury. Eur J Med Res 2024; 29:115. [PMID: 38341556 PMCID: PMC10858548 DOI: 10.1186/s40001-024-01704-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 01/31/2024] [Indexed: 02/12/2024] Open
Affiliation(s)
- Rongping Chen
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China
| | - Beijun Gao
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China
| | - Xinchen Wang
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China
| | - Hua Zhao
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.
| | - Xiaoting Wang
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.
| | - Dawei Liu
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.
| |
Collapse
|
2
|
Dietrich CF, Correas JM, Cui XW, Dong Y, Havre RF, Jenssen C, Jung EM, Krix M, Lim A, Lassau N, Piscaglia F. EFSUMB Technical Review - Update 2023: Dynamic Contrast-Enhanced Ultrasound (DCE-CEUS) for the Quantification of Tumor Perfusion. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2024; 45:36-46. [PMID: 37748503 DOI: 10.1055/a-2157-2587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Dynamic contrast-enhanced ultrasound (DCE-US) is a technique to quantify tissue perfusion based on phase-specific enhancement after the injection of microbubble contrast agents for diagnostic ultrasound. The guidelines of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) published in 2004 and updated in 2008, 2011, and 2020 focused on the use of contrast-enhanced ultrasound (CEUS), including essential technical requirements, training, investigational procedures and steps, guidance regarding image interpretation, established and recommended clinical indications, and safety considerations. However, the quantification of phase-specific enhancement patterns acquired with ultrasound contrast agents (UCAs) is not discussed here. The purpose of this EFSUMB Technical Review is to further establish a basis for the standardization of DCE-US focusing on treatment monitoring in oncology. It provides some recommendations and descriptions as to how to quantify dynamic ultrasound contrast enhancement, and technical explanations for the analysis of time-intensity curves (TICs). This update of the 2012 EFSUMB introduction to DCE-US includes clinical aspects for data collection, analysis, and interpretation that have emerged from recent studies. The current study not only aims to support future work in this research field but also to facilitate a transition to clinical routine use of DCE-US.
Collapse
Affiliation(s)
- Christoph F Dietrich
- Department General Internal Medicine, Kliniken Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland
- Zentrum der Inneren Medizin, Johann Wolfgang Goethe Universitätsklinik Frankfurt, Frankfurt, Germany
| | - Jean-Michel Correas
- Department of Adult Radiology, Assistance Publique Hôpitaux de Paris, Necker University Hospital, Paris, France
- Paris Cité University, Paris, France
- CNRS, INSERM Laboratoire d'Imagerie Biomédicale, Sorbonne Université, Paris, France
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yi Dong
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Roald Flesland Havre
- Department of Medicine, National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Christian Jenssen
- Department of Internal Medicine, Krankenhaus Märkisch Oderland Strausberg/ Wriezen, Wriezen, Germany
- Brandenburg Institute for Clinical Ultrasound (BICUS), Medical University Brandenburg, Neuruppin, Brandenburg, Germany
| | - Ernst Michael Jung
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Martin Krix
- Global Medical & Regulatory Affairs, Bracco Imaging, Konstanz, Germany
| | - Adrian Lim
- Department of Imaging, Imperial College London and Healthcare NHS Trust, Charing Cross Hospital Campus, London, United Kingdom of Great Britain and Northern Ireland
| | - Nathalie Lassau
- Imaging Department. Gustave Roussy cancer Campus. Villejuif, France. BIOMAPS. UMR 1281. CEA. CNRS. INSERM, Université Paris-Saclay, France
| | - Fabio Piscaglia
- Division of Internal Medicine, Hepatobiliary and Immunoallergic Diseases, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
- Dept of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| |
Collapse
|
3
|
Damianaki A, Hendriks-Balk M, Brito W, Polychronopoulou E, Theiler K, Maillard M, Maurer J, Eugster P, Pruijm M, Wuerzner G. Contrast-enhanced ultrasonography reveals a lower cortical perfusion and a decreased renal flow reserve in hypertensive patients. Nephrol Dial Transplant 2024; 39:242-250. [PMID: 37553142 PMCID: PMC10828216 DOI: 10.1093/ndt/gfad158] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Indexed: 08/10/2023] Open
Abstract
BACKGROUND Microvascular structural alteration and dysfunction is a hallmark of arterial hypertension. So far, the visualization and the quantification of renal microcirculation in humans has been hampered by the lack of non-nephrotoxic and non-invasive radiologic techniques. Contrast-enhanced ultrasonography (CEUS) is an appealing method to investigate renal microcirculation and has not been investigated in this setting. We aimed to compare renal microcirculation in normotensive (NT) and hypertensive (HT) participants using CEUS at rest and during a sympathetic stress test. METHODS We measured the renal perfusion index (PI, primary outcome), the renal resistive index (RRI), beat-to-beat systemic hemodynamics and plasma catecholamines before and during a 2-min cold pressor test (CPT) in NT and HT participants. Linear mixed model analysis was used to compare the effect of the CPT on the variables of interest. RESULTS Seventy-three participants (32 HT) with normal kidney function were included. HT participants had a lower baseline PI compared with NT participants [median (interquartile range) 1476 (959-2155) arbitrary units (a.u.) vs 2062 (1438-3318) a.u., P < .001]. The CPT increased blood pressure, heart rate and catecholamines in all participants. The increase in PI observed in NT during the CPT was blunted in HT [+504 (117-920) a.u. vs +1159 (678-2352) a.u in NT, interaction P = .013]. Age, sex and body mass index did not modify these results. CONCLUSIONS HT patients had a lower basal renal cortical perfusion. During the cold pressor test, HT participants had a smaller increase in the PI, suggesting that renal cortical flow reserve is impaired.
Collapse
Affiliation(s)
- Aikaterini Damianaki
- Service of Nephrology and Hypertension, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Mariëlle Hendriks-Balk
- Service of Nephrology and Hypertension, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Wendy Brito
- Service of Nephrology and Hypertension, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Erietta Polychronopoulou
- Service of Nephrology and Hypertension, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Kenji Theiler
- Service of Nephrology and Hypertension, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Marc Maillard
- Service of Nephrology and Hypertension, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Jonathan Maurer
- Service of Clinical Pharmacology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Philippe Eugster
- Service of Clinical Pharmacology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Menno Pruijm
- Service of Nephrology and Hypertension, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Grégoire Wuerzner
- Service of Nephrology and Hypertension, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
4
|
Paratore M, Garcovich M, Ainora ME, Riccardi L, Gasbarrini A, Zocco MA. Dynamic contrast enhanced ultrasound in gastrointestinal diseases: A current trend or an indispensable tool? World J Gastroenterol 2023; 29:4021-4035. [PMID: 37476588 PMCID: PMC10354578 DOI: 10.3748/wjg.v29.i25.4021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 05/24/2023] [Accepted: 06/05/2023] [Indexed: 06/28/2023] Open
Abstract
Contrast enhanced ultrasound (CEUS) has been widely implemented in clinical practice because of the enormous quantity of information it provides, along with its low cost, reproducibility, minimal invasiveness, and safety of the second-generation ultrasound contrast agents. To overcome the limitation of CEUS given by the subjective evaluation of the contrast enhancement behaviour, quantitative analysis of contrast kinetics with generation of time-intensity curves has been introduced in recent years. The quantification of perfusion parameters [named as dynamic-CEUS (D-CEUS)] has several applications in gastrointestinal neoplastic and inflammatory disorders. However, the limited availability of large studies and the heterogeneity of the technologies employed have precluded the standardisation of D-CEUS, which potentially represents a valuable tool for clinical practice in management of gastrointestinal diseases. In this article, we reviewed the evidence exploring the application of D-CEUS in gastrointestinal diseases, with a special focus on liver, pancreas, and inflammatory bowel diseases.
Collapse
Affiliation(s)
- Mattia Paratore
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Matteo Garcovich
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Maria Elena Ainora
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Laura Riccardi
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Antonio Gasbarrini
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Maria Assunta Zocco
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| |
Collapse
|
5
|
The unique second wave phenomenon in contrast enhanced ultrasound imaging with nanobubbles. Sci Rep 2022; 12:13619. [PMID: 35948582 PMCID: PMC9365822 DOI: 10.1038/s41598-022-17756-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 07/30/2022] [Indexed: 12/19/2022] Open
Abstract
Investigation of nanobubble (NB) pharmacokinetics in contrast-enhanced ultrasound (CEUS) at the pixel level shows a unique phenomenon where the first pass of the contrast agent bolus is accompanied by a second wave. This effect has not been previously observed in CEUS with microbubbles. The objective of this study was to investigate this second-wave phenomenon and its potential clinical applications. Seven mice with a total of fourteen subcutaneously-implanted tumors were included in the experiments. After injecting a bolus of NBs, the NB-CEUS images were acquired to record the time-intensity curves (TICs) at each pixel. These TICs are fitted to a pharmacokinetic model which we designed to describe the observed second-wave phenomenon. The estimated model parameters are presented as parametric maps to visualize the characteristics of tumor lesions. Histological analysis was also conducted in one mouse to compare the molecular features of tumor tissue with the obtained parametric maps. The second-wave phenomenon is evidently shown in a series of pixel-based TICs extracted from either tumor or tissues. The value of two model parameters, the ratio of the peak intensities of the second over the first wave, and the decay rate of the wash-out process present large differences between malignant tumor and normal tissue (0.04 < Jessen-Shannon divergence < 0.08). The occurrence of a second wave is a unique phenomenon that we have observed in NB-CEUS imaging of both mouse tumor and tissue. As the characteristics of the second wave are different between tumor and tissue, this phenomenon has the potential to support the diagnosis of cancerous lesions.
Collapse
|
6
|
Hendriks-Balk MC, Damianaki A, Polychronopoulou E, Brito W, Pruijm M, Wuerzner G. Contrast-Enhanced Ultrasonography Enables the Detection of a Cold Pressor Test-Induced Increase in Renal Microcirculation in Healthy Participants. Front Cardiovasc Med 2022; 9:899327. [PMID: 35669471 PMCID: PMC9163379 DOI: 10.3389/fcvm.2022.899327] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 04/19/2022] [Indexed: 11/13/2022] Open
Abstract
BackgroundRenal microcirculation is essential for regulation of the glomerular filtration rate, the reabsorption of salt and water from the interstitium, and hence the blood pressure. Renal ultrasonography coupled to Doppler analysis and contrast-enhanced ultrasound enables the study of renal perfusion. So far, physiologic interventions have rarely been performed to assess the renal perfusion. The objective of our study was to measure the renal perfusion in response to a cold pressor test (CPT).MethodsHealthy adult participants were exposed to a 2 min CPT or a sham exposure (body temperature). Systemic hemodynamics, renal resistive index (RRI) and renal perfusion index (PI) were measured before and during the CPT or the sham exposure. Renal responses were compared using a paired Student's t-test or Wilcoxon signed rank test. Pearson correlation test was used to test association of variables of interest.ResultsForty-one normotensive participants (21 women) were included in the study. Mean blood pressure and heart rate both increased with the CPT. The RRI decreased from 0.60 ± 0.05 arbitrary units (AU) to 0.58 ± 0.05 AU (p < 0.05) and the PI increased from 2,074 AU (1,358–3,346) to 3,800 AU (2,118–6,399) (p < 0.05) (+66% (24–106%)). Compared to the sham exposure, the increase in PI with the CPT was more marked. There was a negative association between the increase in heart rate and mean blood pressure with the RRI (r: −0.550, p = 0.002 and r: −0.395, P = 0.016), respectively.ConclusionDoppler Ultrasound and CEUS enable the detection of physiological changes within the macro- and microvascular renal circulation. The CPT decreases the RRI and increases the PI. Whether these changes are present in pathological states such as diabetes or hypertension will need additional studies.
Collapse
|
7
|
Garessus J, Brito W, Loncle N, Vanelli A, Hendriks-Balk M, Wuerzner G, Schneider A, Burnier M, Pruijm M. Cortical perfusion as assessed with contrast-enhanced ultrasound is lower in patients with chronic kidney disease than in healthy subjects but increases under low salt conditions. Nephrol Dial Transplant 2021; 37:705-712. [DOI: 10.1093/ndt/gfab001] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Indexed: 12/30/2022] Open
Abstract
Abstract
Background
Disturbances in renal microcirculation play an important role in the pathophysiology of chronic kidney disease (CKD), but the lack of easy accessible techniques hampers our understanding of the regulation of the renal microcirculation in humans. We assessed whether contrast-enhanced ultrasound (CEUS) can identify differences in cortical perfusion and alterations induced by different dietary salt intakes in CKD patients and controls.
Methods
Participants underwent CEUS twice: once after 5 days of high-salt (HS) intake, and again after 5 days of low salt (LS) diet. Sonovue® (0.015 mL/kg/min) was perfused as contrast agent and four consecutive destruction–reperfusion sequences were analysed per visit. The primary outcome measure was the (change in) mean perfusion index (PI) of the renal cortex.
Results
Forty healthy volunteers (mean age ± standard deviation 50 ± 8 years) and 18 CKD Stages 2–4 patients [aged 55 ± 11 years, estimated glomerular filtration rate (eGFR) 54 ± 28 mL/min/1.73 m2] were included and underwent CEUS without side effects. Under HS conditions, cortical PI was significantly lower in CKD patients [1618 ± 1352 versus 3176 ± 2278 arbitrary units (a.u) in controls, P = 0.034]. Under LS, renal PI increased in CKD patients (with +1098 to 2716 ± 1540 a.u., P = 0.048), whereas PI remained stable in controls. In the continuous analysis, PI correlated with eGFR (Spearman’s r = 0.54, P = 0.005) but not with age, sex, blood pressure or aldosterone levels.
Conclusions
CEUS identified important reductions in cortical micro-perfusion in patients with moderate CKD. Lowering salt intake increased perfusion in CKD patients, but not in controls, underlining the benefits of an LS diet in CKD patients. Whether a low PI is an early sign of kidney damage and predicts renal function decline needs further study.
Collapse
Affiliation(s)
- Jonas Garessus
- Service of Nephrology, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
| | - Wendy Brito
- Service of Nephrology, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
| | - Nicolas Loncle
- Service of Nephrology, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
| | - Anna Vanelli
- Service of Nephrology, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
| | - Marielle Hendriks-Balk
- Service of Nephrology, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
| | - Grégoire Wuerzner
- Service of Nephrology, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
| | - Antoine Schneider
- Adult Intensive Care Unit, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
| | - Michel Burnier
- Service of Nephrology, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
| | - Menno Pruijm
- Service of Nephrology, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
8
|
Therapeutic response monitoring after targeted therapy in an orthotopic rat model of hepatocellular carcinoma using contrast-enhanced ultrasound: Focusing on inter-scanner, and inter-operator reproducibility. PLoS One 2020; 15:e0244304. [PMID: 33362203 PMCID: PMC7757904 DOI: 10.1371/journal.pone.0244304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Accepted: 12/03/2020] [Indexed: 11/30/2022] Open
Abstract
Purpose To assess therapeutic response monitoring after targeted therapy in an orthotopic rat model of hepatocellular carcinoma (HCC) using CEUS with focusing on inter-scanner and inter-operator reproducibility. Materials and methods For reproducibility, CEUS was performed using two different US scanners by two operators in sixteen rat models of HCC. Using perfusion analysis software (VueBox ®), eleven parameters were collected, and intra-class correlation coefficient (ICC) was used to analyze reproducibility. Then seventeen rat models of HCC were divided into treatment group (n = 8, 30 mg/kg/day sorafenib for five days) and control group (n = 9). CEUS was performed at baseline and 14 days after first treatment, and changes of perfusion parameters were analyzed. Results In treatment group, CEUS perfusion parameters showed a significant change. The peak enhancement (PE, 2.50 x103±1.68 x103 vs 5.55x102±4.65x102, p = 0.010) and wash-in and wash out AUC (WiWoAUC, 1.07x105±6.48 x104 vs 2.65x104±2.25x104, p = 0.009) had significantly decreased two weeks after treatment. On the contrary, control group did not show a significant change, including PE (1.15 x103±7.53x102 vs 9.43x102± 7.81 x102, p = 0.632) and WiWoAUC (5.09 x104±3.25x104 vs 5.92 x104±3.20x104, p = 0.646). For reproducibility, the various degrees of inter-scanner reproducibility were from poor to good (ICC: <0.01–0.63). However, inter-operator reproducibility of important perfusion parameters, including WiAUC, WoAUC, and WiWoAUC, ranged from fair to excellent (ICC: 0.59–0.93) in a different scanner. Conclusion Our results suggest that CEUS is useful for assessment of the treatment response after targeted therapy and with fair to excellent inter-operator reproducibility.
Collapse
|
9
|
Lamuraglia M, Barrois G, Le Guillou-Buffello D, Santin M, Kerbol A, Comperat E, Coron A, Lucidarme O, Bridal SL. Monitoring Dual VEGF Inhibition in Human Pancreatic Tumor Xenografts With Dynamic Contrast-Enhanced Ultrasound. Technol Cancer Res Treat 2020; 19:1533033819886896. [PMID: 32065066 PMCID: PMC7026814 DOI: 10.1177/1533033819886896] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Association of drugs acting against different antiangiogenic mechanisms may increase therapeutic effect and reduce resistance. Noninvasive monitoring of changes in the antiangiogenic response of individual tumors could guide selection and administration of drug combinations. Noninvasive detection of early therapeutic response during dual, vertical targeting of the vascular endothelial growth factor pathway was investigated in an ectopic subcutaneous xenograft model for human pancreatic tumor. METHODS Dynamic contrast-enhanced ultrasound 12 MHz was used to monitor tumor-bearing Naval Medical Research Institute mice beginning 15 days after tumor implantation. Mice received therapy from 15 to 29 days with sorafenib (N = 9), ziv-aflibercept (N = 11), combined antiangiogenic agents (N = 11), and placebo control (N = 14). Sorafenib (BAY 43-9006; Nexavar), a multikinase inhibitor acting on Raf kinase and receptor tyrosine kinases-including vascular endothelial growth factor receptors 2 and 3-was administered daily (60 mg/kg, per os). Ziv-aflibercept (ZALTRAP), a high-affinity ligand trap blocking the activity of vascular endothelial growth factor A, vascular endothelial growth factor B, and placental growth factor was administered twice per week (40 mg/kg, intraperitoneally). RESULTS Functional evaluation with dynamic contrast-enhanced ultrasound indicated stable tumor vascularization for the control group while revealing significant and sustained reduction after 1 day of therapy in the combined group (P = .007). There was no survival benefit or penalty due to drug combination. The functional progression-free survival assessed with dynamic contrast-enhanced ultrasound was significantly higher for the 3 treated groups; whereas, the progression-free survival based on tumor size did not discriminate therapeutic effect. CONCLUSIONS Dynamic contrast-enhanced ultrasound, therefore, presents strong potential to monitor microvascular modifications during antiangiogenic therapy, a key role to monitoring antiangiogenic combining therapy to adapt dose range drug.
Collapse
Affiliation(s)
- Michele Lamuraglia
- Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale (LIB), AP-HP, Hôpital Beaujon, Paris, France
| | - Guillaume Barrois
- Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale (LIB), Paris, France
| | | | - Mathieu Santin
- Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale (LIB), Paris, France
| | - Anne Kerbol
- Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale (LIB), AP-HP, Hôpital Beaujon, Paris, France
| | - Eva Comperat
- Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale (LIB), Paris, France
| | - Alain Coron
- Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale (LIB), Paris, France
| | - Olivier Lucidarme
- Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale (LIB), AP-HP, Hôpital Pitié-Salpêtrière, Paris, France
| | - S Lori Bridal
- Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale (LIB), Paris, France
| |
Collapse
|
10
|
Averkiou MA, Bruce MF, Powers JE, Sheeran PS, Burns PN. Imaging Methods for Ultrasound Contrast Agents. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:498-517. [PMID: 31813583 DOI: 10.1016/j.ultrasmedbio.2019.11.004] [Citation(s) in RCA: 76] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 11/05/2019] [Accepted: 11/08/2019] [Indexed: 05/23/2023]
Abstract
Microbubble contrast agents were introduced more than 25 years ago with the objective of enhancing blood echoes and enabling diagnostic ultrasound to image the microcirculation. Cardiology and oncology waited anxiously for the fulfillment of that objective with one clinical application each: myocardial perfusion, tumor perfusion and angiogenesis imaging. What was necessary though at first was the scientific understanding of microbubble behavior in vivo and the development of imaging technology to deliver the original objective. And indeed, for more than 25 years bubble science and imaging technology have evolved methodically to deliver contrast-enhanced ultrasound. Realization of the basic bubbles properties, non-linear response and ultrasound-induced destruction, has led to a plethora of methods; algorithms and techniques for contrast-enhanced ultrasound (CEUS) and imaging modes such as harmonic imaging, harmonic power Doppler, pulse inversion, amplitude modulation, maximum intensity projection and many others were invented, developed and validated. Today, CEUS is used everywhere in the world with clinical indications both in cardiology and in radiology, and it continues to mature and evolve and has become a basic clinical tool that transforms diagnostic ultrasound into a functional imaging modality. In this review article, we present and explain in detail bubble imaging methods and associated artifacts, perfusion quantification approaches, and implementation considerations and regulatory aspects.
Collapse
Affiliation(s)
| | - Matthew F Bruce
- Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | | | - Paul S Sheeran
- Philips Ultrasound, Bothell, Washington, USA; Knight Cardiovascular Institute, Oregon Health and Science University, Portland, Oregon, USA
| | - Peter N Burns
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada; Imaging Research, Sunnybrook Research Institute, Toronto, Ontario, Canada
| |
Collapse
|
11
|
Turco S, Frinking P, Wildeboer R, Arditi M, Wijkstra H, Lindner JR, Mischi M. Contrast-Enhanced Ultrasound Quantification: From Kinetic Modeling to Machine Learning. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:518-543. [PMID: 31924424 DOI: 10.1016/j.ultrasmedbio.2019.11.008] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 11/13/2019] [Accepted: 11/14/2019] [Indexed: 05/14/2023]
Abstract
Ultrasound contrast agents (UCAs) have opened up immense diagnostic possibilities by combined use of indicator dilution principles and dynamic contrast-enhanced ultrasound (DCE-US) imaging. UCAs are microbubbles encapsulated in a biocompatible shell. With a rheology comparable to that of red blood cells, UCAs provide an intravascular indicator for functional imaging of the (micro)vasculature by quantitative DCE-US. Several models of the UCA intravascular kinetics have been proposed to provide functional quantitative maps, aiding diagnosis of different pathological conditions. This article is a comprehensive review of the available methods for quantitative DCE-US imaging based on temporal, spatial and spatiotemporal analysis of the UCA kinetics. The recent introduction of novel UCAs that are targeted to specific vascular receptors has advanced DCE-US to a molecular imaging modality. In parallel, new kinetic models of increased complexity have been developed. The extraction of multiple quantitative maps, reflecting complementary variables of the underlying physiological processes, requires an integrative approach to their interpretation. A probabilistic framework based on emerging machine-learning methods represents nowadays the ultimate approach, improving the diagnostic accuracy of DCE-US imaging by optimal combination of the extracted complementary information. The current value and future perspective of all these advances are critically discussed.
Collapse
Affiliation(s)
- Simona Turco
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | | | - Rogier Wildeboer
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marcel Arditi
- École polytechnique fédérale de Lausanne, Lausanne, Switzerland
| | - Hessel Wijkstra
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Amsterdam University Medical Center, Amsterdam, The Netherlands
| | - Jonathan R Lindner
- Knight Cardiovascular Center, Oregon Health & Science University, Portland, Oregon, USA
| | - Massimo Mischi
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
12
|
Abstract
Contrast-enhanced ultrasound (CEUS) imaging is a valuable tool for preclinical and clinical diagnostics. The most frequently used ultrasound contrast agents are microbubbles. Besides them, novel nano-sized materials are under investigation, which are briefly discussed in this chapter. For molecular CEUS, the ultrasound contrast agents are modified to actively target disease-associated molecular markers with a site-specific ligand. The most common markers for tumor imaging are related to neoangiogenesis, like the vascular endothelial growth factor receptor-2 (VEGFR2) and αvβ3 integrin. In this chapter, applications of molecular ultrasound to longitudinally monitor receptor expression during tumor growth, to detect neovascularization, and to evaluate therapy responses are described. Furthermore, we report on first clinical trials of molecular CEUS with VEGFR2-targeted phospholipid microbubbles showing promising results regarding patient safety and its ability to detect tumors of prostate, breast, and ovary. The chapter closes with an outlook on ultrasound theranostics, where (targeted) ultrasound contrast agents are used to increase the permeability of tumor tissues and to support drug delivery.
Collapse
Affiliation(s)
- Jasmin Baier
- Institute for Experimental Molecular Imaging Organization University Clinics, RWTH Aachen University, Forckenbeckstrasse 55, 52074 Aachen, Germany
| | - Anne Rix
- Institute for Experimental Molecular Imaging Organization University Clinics, RWTH Aachen University, Forckenbeckstrasse 55, 52074 Aachen, Germany
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging Organization University Clinics, RWTH Aachen University, Forckenbeckstrasse 55, 52074 Aachen, Germany.
| |
Collapse
|
13
|
Abstract
METHODICAL ISSUE Contrast-enhanced ultrasound (CEUS) offers easily accessible visualization and quantification of the skeletal muscle microcirculation and other tissues in vivo and in real-time with almost no side effects. AIM The aim of this review is to present the increasing number of musculoskeletal CEUS applications. METHODICAL INNOVATIONS/PERFORMANCE CEUS applications regarding the musculoskeletal system include applications at bone and joints extending beyond the visualization of only the muscular microcirculation. Besides basic muscle physiology, impaired microcirculation in patients with peripheral artery disease or diabetes mellitus and the diagnosis of inflammatory myopathies have been the subject of previous CEUS studies. More recent studies in orthopedics and traumatology have focused on osseous and muscular perfusion characteristics, e. g., in differentiating infected and aseptic non-unions or the impact of different types of implants and prostheses on muscular microcirculation as a surrogate marker of clinical success. PRACTICAL RECOMMENDATIONS CEUS of the musculoskeletal system is used in clinical trials or off-label. Therefore, it is not well established in clinical routine. However, considering the increasing number of musculoskeletal CEUS applications, this could change in the future.
Collapse
|
14
|
Alberich-Bayarri Á, Tomás-Cucarella J, Torregrosa-Lloret A, Sáiz Rodriguez J, Martí-Bonmatí L. Optimisation of ultrasound liver perfusion through a digital reference object and analysis tool. Eur Radiol Exp 2019; 3:15. [PMID: 30945029 PMCID: PMC6447630 DOI: 10.1186/s41747-019-0086-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Accepted: 01/04/2019] [Indexed: 11/10/2022] Open
Abstract
Background Conventional ultrasound (US) provides important qualitative information, although there is a need to evaluate the influence of the input parameters on the output signal and standardise the acquisition for an adequate quantitative perfusion assessment. The present study analyses how the variation in the input parameters influences the measurement of the perfusion parameters. Methods A software tool with simulator of the conventional US signal was created, and the influence of the different input variables on the derived biomarkers was analysed by varying the image acquisition configuration. The input parameters considered were the dynamic range, gain, and frequency of the transducer. Their influence on mean transit time (MTT), the area under the curve (AUC), maximum intensity (MI), and time to peak (TTP) parameters as outputs of the quantitative perfusion analysis was evaluated. A group of 13 patients with hepatocarcinoma was analysed with both a commercial tool and an in-house developed software. Results The optimal calculated inputs which minimise errors while preserving images’ readability consisted of gain of 15 dB, dynamic range of 60 dB, and frequency of 1.5 MHz. The comparison between the in-house developed software and the commercial software provided different values for MTT and AUC, while MI and TTP were highly similar. Conclusion Input parameter selection introduces variability and errors in US perfusion parameter estimation. Our results may add relevant insight into the current knowledge of conventional US perfusion and its use in lesions characterisation, playing in favour of optimised standardised parameter configuration to minimise variability.
Collapse
Affiliation(s)
- Ángel Alberich-Bayarri
- Biomedical Imaging Research Group (GIBI2^30), Hospital Universitari i Politècnic La Fe, Avda. Fernando Abril Martorell 106, Torre A, 46026, Valencia, Spain. .,Quantitative Imaging Biomarkers in Medicine, QUIBIM SL, Valencia, Spain.
| | - Jose Tomás-Cucarella
- Biomedical Imaging Research Group (GIBI2^30), Hospital Universitari i Politècnic La Fe, Avda. Fernando Abril Martorell 106, Torre A, 46026, Valencia, Spain
| | | | - Javier Sáiz Rodriguez
- Department of Electronics Engineering, Polytechnics University of Valencia, Valencia, Spain
| | - Luis Martí-Bonmatí
- Biomedical Imaging Research Group (GIBI2^30), Hospital Universitari i Politècnic La Fe, Avda. Fernando Abril Martorell 106, Torre A, 46026, Valencia, Spain
| |
Collapse
|
15
|
Quaia E, Gennari AG, Cova MA. Early Predictors of the Long-term Response to Therapy in Patients With Crohn Disease Derived From a Time-Intensity Curve Analysis After Microbubble Contrast Agent Injection. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:947-958. [PMID: 30208230 DOI: 10.1002/jum.14778] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Accepted: 07/13/2018] [Indexed: 06/08/2023]
Abstract
OBJECTIVES The aim of this study was to identify early predictors of the long-term response to therapy in patients with Crohn disease (CD) from time-intensity curves obtained after microbubble injection. METHODS One hundred fifteen consecutive patients with a proven diagnosis of CD involving the terminal ileal loop who were scheduled to begin pharmacologic therapy with biologics (infliximab or adalimumab) were scanned after sulfur hexafluoride-filled microbubble injection before the beginning and at the end of the sixth week of treatment. The absolute value and percentage change of each semiquantitative kinetic parameter (peak enhancement, time to peak enhancement, rise time, mean transit time, wash-in and wash-out rates, area under the curve [AUC] for the whole time-intensity curve, AUC during wash-in, AUC during wash-out, and wash-in perfusion index) as measured on the terminal ileal tract and adjacent reactive mesenteric fat were calculated from time-intensity curves. Patients were followed for at least 24 months with redetermination of the Crohn Disease Activity Index and with at least 1 endoscopy within 18 weeks after the beginning of pharmacologic treatment. The absolute values and percentage changes of kinetic parameters were assessed as potential predictors of the therapeutic outcome by a logistic regression analysis. RESULTS The study group included 66 male and 49 female patients (mean age ± SD, 45.76 ± 11 years). The pretreatment values and percentage changes of the peak enhancement, AUC, AUC during wash-in, and AUC during wash-out were found to be predictors (P < .05) of the long-term therapeutic outcome. CONCLUSIONS The analysis of time-intensity curves obtained after microbubble contrast agent injection provides early predictors of the long-term therapeutic outcome in patients with CD.
Collapse
Affiliation(s)
- Emilio Quaia
- Department of Radiology, University of Padova, Via Giustiniani 2, 35128, Padova (Italy)
| | | | - Maria Assunta Cova
- Department of Radiology, Cattinara Hospital, University of Trieste, Trieste, Italy
| |
Collapse
|
16
|
Wang D, Su Z, Su Q, Zhang X, Qu Z, Wang N, Zong Y, Yang Y, Wan M. Evaluation of accuracy of automatic out-of-plane respiratory gating for DCEUS-based quantification using principal component analysis. Comput Med Imaging Graph 2018; 70:155-164. [DOI: 10.1016/j.compmedimag.2018.10.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2018] [Revised: 09/01/2018] [Accepted: 10/18/2018] [Indexed: 01/24/2023]
|
17
|
Wang H, Hyvelin JM, Felt SA, Guracar I, Vilches-Moure JG, Cherkaoui S, Bettinger T, Tian L, Lutz AM, Willmann JK. US Molecular Imaging of Acute Ileitis: Anti-Inflammatory Treatment Response Monitored with Targeted Microbubbles in a Preclinical Model. Radiology 2018; 289:90-100. [PMID: 30040040 PMCID: PMC6190483 DOI: 10.1148/radiol.2018172600] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2018] [Revised: 04/24/2018] [Accepted: 05/09/2018] [Indexed: 12/30/2022]
Abstract
Purpose To evaluate whether dual-selectin-targeted US molecular imaging allows longitudinal monitoring of anti-inflammatory treatment effects in an acute terminal ileitis model in swine. Materials and Methods The Institutional Animal Care and Use Committee approved all animal studies. Fourteen swine with chemically induced acute terminal ileitis (day 0) were randomized into the following groups: (a) an anti-inflammatory treatment group (n = 8; meloxicam, 0.25 mg per kilogram of body weight; prednisone, 0.5 mg/kg) and (b) a control group (n = 6; saline). US molecular imaging was performed with a clinical US machine after intravenous injection of clinically translatable dual P- and E-selectin-targeted microbubbles (5 × 108/kg). Three inflamed bowel segments per swine were imaged at baseline, as well as on days 1, 3, and 6 after treatment initiation. At day 6, bowel segments were analyzed ex vivo for selectin expression levels by using quantitative immunofluorescence. Results After induction of inflammation, US molecular imaging signal increased at day 1 in both animal groups (P < .001). At day 3, signal in the treatment group decreased (P < .001 vs day 1), while signal in control animals did not significantly change (P = .18 vs day 1) and was higher (P = .001) compared with that in the treatment group. At day 6, signal in the treatment group further decreased and remained lower (P = .02) compared with that in the control group. Immunofluorescence confirmed significant (P ≤ .04) downregulation of both P- and E-selectin expression levels in treated versus control bowel segments. Conclusion Dual-selectin-targeted US molecular imaging allows longitudinal monitoring of anti-inflammatory treatment effects in a large-animal model of acute ileitis. This supports further clinical development of this quantitative and radiation-free technique for monitoring inflammatory bowel disease. © RSNA, 2018 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Huaijun Wang
- From the Department of Radiology, Stanford University School of
Medicine, 300 Pasteur Dr, Grant SO62B, Stanford, CA 94305-5105 (H.W., A.M.L.,
J.K.W.); Bracco Suisse SA, Geneva, Switzerland (J.M.H., S.C., T.B.); Departments
of Comparative Medicine (S.A.F., J.G.V.) and Health, Research & Policy
(L.T.), Stanford University, Stanford, Calif; and Ultrasound Business Unit,
Siemens Healthcare, Mountain View, Calif (I.G.)
| | - Jean-Marc Hyvelin
- From the Department of Radiology, Stanford University School of
Medicine, 300 Pasteur Dr, Grant SO62B, Stanford, CA 94305-5105 (H.W., A.M.L.,
J.K.W.); Bracco Suisse SA, Geneva, Switzerland (J.M.H., S.C., T.B.); Departments
of Comparative Medicine (S.A.F., J.G.V.) and Health, Research & Policy
(L.T.), Stanford University, Stanford, Calif; and Ultrasound Business Unit,
Siemens Healthcare, Mountain View, Calif (I.G.)
| | - Stephen A. Felt
- From the Department of Radiology, Stanford University School of
Medicine, 300 Pasteur Dr, Grant SO62B, Stanford, CA 94305-5105 (H.W., A.M.L.,
J.K.W.); Bracco Suisse SA, Geneva, Switzerland (J.M.H., S.C., T.B.); Departments
of Comparative Medicine (S.A.F., J.G.V.) and Health, Research & Policy
(L.T.), Stanford University, Stanford, Calif; and Ultrasound Business Unit,
Siemens Healthcare, Mountain View, Calif (I.G.)
| | - Ismayil Guracar
- From the Department of Radiology, Stanford University School of
Medicine, 300 Pasteur Dr, Grant SO62B, Stanford, CA 94305-5105 (H.W., A.M.L.,
J.K.W.); Bracco Suisse SA, Geneva, Switzerland (J.M.H., S.C., T.B.); Departments
of Comparative Medicine (S.A.F., J.G.V.) and Health, Research & Policy
(L.T.), Stanford University, Stanford, Calif; and Ultrasound Business Unit,
Siemens Healthcare, Mountain View, Calif (I.G.)
| | - Jose G. Vilches-Moure
- From the Department of Radiology, Stanford University School of
Medicine, 300 Pasteur Dr, Grant SO62B, Stanford, CA 94305-5105 (H.W., A.M.L.,
J.K.W.); Bracco Suisse SA, Geneva, Switzerland (J.M.H., S.C., T.B.); Departments
of Comparative Medicine (S.A.F., J.G.V.) and Health, Research & Policy
(L.T.), Stanford University, Stanford, Calif; and Ultrasound Business Unit,
Siemens Healthcare, Mountain View, Calif (I.G.)
| | - Samir Cherkaoui
- From the Department of Radiology, Stanford University School of
Medicine, 300 Pasteur Dr, Grant SO62B, Stanford, CA 94305-5105 (H.W., A.M.L.,
J.K.W.); Bracco Suisse SA, Geneva, Switzerland (J.M.H., S.C., T.B.); Departments
of Comparative Medicine (S.A.F., J.G.V.) and Health, Research & Policy
(L.T.), Stanford University, Stanford, Calif; and Ultrasound Business Unit,
Siemens Healthcare, Mountain View, Calif (I.G.)
| | - Thierry Bettinger
- From the Department of Radiology, Stanford University School of
Medicine, 300 Pasteur Dr, Grant SO62B, Stanford, CA 94305-5105 (H.W., A.M.L.,
J.K.W.); Bracco Suisse SA, Geneva, Switzerland (J.M.H., S.C., T.B.); Departments
of Comparative Medicine (S.A.F., J.G.V.) and Health, Research & Policy
(L.T.), Stanford University, Stanford, Calif; and Ultrasound Business Unit,
Siemens Healthcare, Mountain View, Calif (I.G.)
| | - Lu Tian
- From the Department of Radiology, Stanford University School of
Medicine, 300 Pasteur Dr, Grant SO62B, Stanford, CA 94305-5105 (H.W., A.M.L.,
J.K.W.); Bracco Suisse SA, Geneva, Switzerland (J.M.H., S.C., T.B.); Departments
of Comparative Medicine (S.A.F., J.G.V.) and Health, Research & Policy
(L.T.), Stanford University, Stanford, Calif; and Ultrasound Business Unit,
Siemens Healthcare, Mountain View, Calif (I.G.)
| | - Amelie M. Lutz
- From the Department of Radiology, Stanford University School of
Medicine, 300 Pasteur Dr, Grant SO62B, Stanford, CA 94305-5105 (H.W., A.M.L.,
J.K.W.); Bracco Suisse SA, Geneva, Switzerland (J.M.H., S.C., T.B.); Departments
of Comparative Medicine (S.A.F., J.G.V.) and Health, Research & Policy
(L.T.), Stanford University, Stanford, Calif; and Ultrasound Business Unit,
Siemens Healthcare, Mountain View, Calif (I.G.)
| | | |
Collapse
|
18
|
Wang D, Xiao M, Zhang Y, Wan M. Abdominal parametric perfusion imaging with respiratory motion-compensation based on contrast-enhanced ultrasound: In-vivo validation. Comput Med Imaging Graph 2018; 65:11-21. [DOI: 10.1016/j.compmedimag.2017.06.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Revised: 06/03/2017] [Accepted: 06/19/2017] [Indexed: 10/19/2022]
|
19
|
Abstract
Contrast-enhanced ultrasound (CEUS) of the gastrointestinal tract provides vascular information helpful for characterizing masses and other pathologies in and around the bowel, similar to contrast applications in other solid organs. However, the use of microbubble contrast agents for the bowel provides additional unique contributions as it gives both subjective and objective information about mural and mesenteric blood flow, invaluable for the determination of disease activity in those many patients affected by inflammatory bowel disease (IBD). IBD is a lifelong chronic disease and has its peak age of onset in adolescence or young adult life. Today, we have moved away from treating patient’s symptoms and strive instead to alter the course of disease by obtaining mucosal healing. Expensive and aggressive biologic therapies and lack of agreement of patient’s symptoms with their disease activity and complications necessitate frequent imaging surveillance, which must be safe, readily available, inexpensive, and effective. Ultrasound with the benefit of contrast enhancement meets these requirements and is shown in meta-analysis to be equivalent to CT and MRI scans for these indications.
Collapse
|
20
|
Wang D, Xiao M, Zhang Y, Su Z, Zong Y, Wang S, Wan M. In-vitro evaluation of accuracy of dynamic contrast-enhanced ultrasound (DCEUS)-based parametric perfusion imaging with respiratory motion-compensation. Med Phys 2018; 45:2119-2128. [PMID: 29574795 DOI: 10.1002/mp.12872] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 02/14/2018] [Accepted: 03/01/2018] [Indexed: 01/24/2023] Open
Abstract
PURPOSE The accuracy of multi-parametric perfusion imaging (PPI) based on dynamic contrast-enhanced ultrasound is disturbed by the respiratory motion in some cases, especially during characterizing hemodynamic features of abdominal tumor angiogenesis. This study aimed to effectively remove those disturbances on PPI and evaluate its accuracy. METHOD The respiratory motion-compensation (rMoCo) strategy in PPI was modified by employing non-negative matrix factorization combined with phase-by-phase compensation. According to the known and controllable ground truths in in-vitro perfusion experiments, the accuracy of the modified rMoCo strategy was further evaluated from multiple perspectives in a simulated dual-vessel flow phantom. RESULTS Compared with that of PPIs without rMoCo, the mean correlation coefficient between six PPIs with rMoCo and the corresponding static PPIs was up to 0.98 ± 0.01 and improved by 0.17 ± 0.04 (P < 0.05). The estimated error of vascular diameter decreased from 87.85% (P < 0.05) to 7.25% (P < 0.05) after rMoCo. PPIs with rMoCo were significantly consistent with static PPIs without respiratory motion disturbances. CONCLUSIONS These quantitative results illustrated the disturbances induced by respiratory motion were effectively removed and the accuracy of PPIs was significantly improved. The partial parabolic and bimodal hemodynamic characteristics and the anatomical structures and sizes were accurately quantified and depicted by PPIs with rMoCo. The modified method can benefit physicians in providing accurate diagnoses and in developing appropriate therapeutic strategies for abdominal diseases.
Collapse
Affiliation(s)
- Diya Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, 710049, China.,Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montreal, Quebec, H2X 0A9, Canada
| | - Mengnan Xiao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, 710049, China
| | - Yu Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, 710049, China
| | - Zhe Su
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, 710049, China
| | - Yujin Zong
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, 710049, China
| | - Supin Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, 710049, China
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, 710049, China
| |
Collapse
|
21
|
Wang D, Xiao M, Hu H, Zhang Y, Su Z, Xu S, Zong Y, Wan M. DCEUS-based focal parametric perfusion imaging of microvessel with single-pixel resolution and high contrast. ULTRASONICS 2018; 84:392-403. [PMID: 29245119 DOI: 10.1016/j.ultras.2017.11.018] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Revised: 11/23/2017] [Accepted: 11/29/2017] [Indexed: 06/07/2023]
Abstract
This study aimed to develop a focal microvascular contrast-enhanced ultrasonic parametric perfusion imaging (PPI) scheme to overcome the tradeoff between the resolution, contrast, and accuracy of focal PPI in the tumor. Its resolution was limited by the low signal-to-clutter ratio (SCR) of time-intensity-curves (TICs) induced by multiple limitations, which deteriorated the accuracy and contrast of focal PPI. The scheme was verified by the in-vivo perfusion experiments. Single-pixel TICs were first extracted to ensure PPI with the highest resolution. The SCR of focal TICs in the tumor was improved using respiratory motion compensation combined with detrended fluctuation analysis. The entire and focal PPIs of six perfusion parameters were then accurately created after filtrating the valid TICs and targeted perfusion parameters. Compared with those of the conventional PPIs, the axial and lateral resolutions of focal PPIs were improved by 30.29% (p < .05) and 32.77% (p < .05), respectively; the average contrast and accuracy evaluated by SCR improved by 7.24 ± 4.90 dB (p < .05) and 5.18 ± 1.28 dB (p < .05), respectively. The edge, morphostructure, inhomogeneous hyper-enhanced distribution, and ring-like perfusion features in intratumoral microvessel were accurately distinguished and highlighted by the focal PPIs. The developed focal PPI can assist clinicians in making confirmed diagnoses and in providing appropriate therapeutic strategies for liver tumor.
Collapse
Affiliation(s)
- Diya Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, PR China; Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montreal, QC, Canada
| | - Mengnan Xiao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, PR China
| | - Hong Hu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, PR China
| | - Yu Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, PR China
| | - Zhe Su
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, PR China
| | - Shanshan Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, PR China
| | - Yujin Zong
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, PR China
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, PR China.
| |
Collapse
|
22
|
Ultrasound in Infertility Setting: Optimal Strategy to Evaluate the Assessment of Tubal Patency. BIOMED RESEARCH INTERNATIONAL 2017; 2017:3205895. [PMID: 29376069 PMCID: PMC5742425 DOI: 10.1155/2017/3205895] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Accepted: 11/19/2017] [Indexed: 11/25/2022]
Abstract
Tubal patency is a key element in women who are undergoing assisted reproductive techniques (ART), in order to attempt or exclude intrauterine insemination (IUI) cycles. Amongst the different procedures that can be used, without resorting to laparoscopy that remains the gold standard, hystero-salpingo-contrast sonography (HyCoSy) is an acceptable, time-efficient, and well tolerated option; it can be performed with administration of saline and air simultaneously or alternately (air/saline-HyCoSy), or with some other contrast agents, like SonoVue (sulfur hexafluoride microbubbles). In this paper, we describe two different studies: in the first one, our aim is to compare the efficiency of air/saline-HyCoSy with HyCoSy performed with contrast media (SonoVue), considering hysterosalpingography (HSG) and laparoscopy (LPS) as reference tests; in the second one, we estimate the pregnancy rate of a cohort of infertile women selected to undergo IUI cycles after tubal bilateral patency demonstration with air/saline-HyCoSy, to understand if this technique can be used as an efficient screening procedure in a Reproductive Unit.
Collapse
|
23
|
Schellhaas B, Waldner M, Görtz R, Vitali F, Kielisch C, Pfeifer L, Strobel D, Janka R, Neurath M, Wildner D. Diagnostic accuracy and interobserver variability of Dynamic Vascular Pattern (DVP) in primary liver malignancies – A simple semiquantitative tool for the analysis of contrast enhancement patterns. Clin Hemorheol Microcirc 2017; 66:317-331. [DOI: 10.3233/ch-16238] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- B. Schellhaas
- Department of Internal Medicine 1, Erlangen University Hospital, FAU University of Erlangen-Nürnberg, Erlangen, Germany
| | - M.J. Waldner
- Department of Internal Medicine 1, Erlangen University Hospital, FAU University of Erlangen-Nürnberg, Erlangen, Germany
| | - R.S. Görtz
- Department of Internal Medicine 1, Erlangen University Hospital, FAU University of Erlangen-Nürnberg, Erlangen, Germany
| | - F. Vitali
- Department of Internal Medicine 1, Erlangen University Hospital, FAU University of Erlangen-Nürnberg, Erlangen, Germany
| | - Ch. Kielisch
- Department of Internal Medicine 1, Erlangen University Hospital, FAU University of Erlangen-Nürnberg, Erlangen, Germany
| | - L. Pfeifer
- Department of Internal Medicine 1, Erlangen University Hospital, FAU University of Erlangen-Nürnberg, Erlangen, Germany
| | - D. Strobel
- Department of Internal Medicine 1, Erlangen University Hospital, FAU University of Erlangen-Nürnberg, Erlangen, Germany
| | - R. Janka
- Department of Radiology, Erlangen University Hospital, FAU University of Erlangen-Nürnberg, Erlangen, Germany
| | - M.F. Neurath
- Department of Internal Medicine 1, Erlangen University Hospital, FAU University of Erlangen-Nürnberg, Erlangen, Germany
| | - D. Wildner
- Department of Internal Medicine 1, Erlangen University Hospital, FAU University of Erlangen-Nürnberg, Erlangen, Germany
| |
Collapse
|
24
|
Shirinifard A, Thiagarajan S, Johnson MD, Calabrese C, Sablauer A. Measuring Absolute Blood Perfusion in Mice Using Dynamic Contrast-Enhanced Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1628-1638. [PMID: 28522149 DOI: 10.1016/j.ultrasmedbio.2017.02.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 01/31/2017] [Accepted: 02/04/2017] [Indexed: 06/07/2023]
Abstract
We investigated the feasibility of estimating absolute tissue blood perfusion using dynamic contrast-enhanced ultrasound (CEUS) imaging in mice. We developed a novel method of microbubble administration and a model-free approach to estimate absolute kidney perfusion, and explored the kidney as a reference organ to estimate absolute perfusion of a neuroblastoma tumor. We performed CEUS on the kidneys of CD1 nude mice using the VisualSonics VEVO 2100 imaging system. We estimated individual kidney blood perfusion using the burst-replenishment (BR) technique. We repeated the kidney imaging on the mice after a week. We performed CEUS imaging of a neuroblastoma mouse xenograft tumor along with its right kidney using two sets of microbubble administration parameters to estimate absolute tumor blood perfusion. We performed statistical tests at a significance level of 0.05. Our estimated absolute kidney perfusion (425 ± 123 mL/min/100 g) was within the range of previously reported values. There was no statistical difference between the estimated absolute kidney blood perfusions from the 2 wk of imaging (paired t-test, p = 0.09). We estimated the absolute blood perfusion in the neuroblastoma tumor to be 16.49 and 16.9 mL/min/100 g for the two sets of microbubble administration parameters (Wilcoxon rank-sum test, p = 0.6). We have established the kidney as a reliable reference organ in which to estimate absolute perfusion of other tissues. Using a neuroblastoma tumor, we have determined the feasibility of estimating absolute blood perfusion in tissues using contrast-enhanced ultrasound imaging.
Collapse
Affiliation(s)
- Abbas Shirinifard
- Department of Information Sciences, St. Jude Children's Research Hospital, Memphis, Tennessee, USA
| | - Suresh Thiagarajan
- Department of Pathology, St. Jude Children's Research Hospital, Memphis, Tennessee, USA
| | - Melissa D Johnson
- Department of Small Animal Imaging, St. Jude Children's Research Hospital, Memphis, Tennessee, USA
| | - Christopher Calabrese
- Department of Small Animal Imaging, St. Jude Children's Research Hospital, Memphis, Tennessee, USA
| | - András Sablauer
- Department of Information Sciences, St. Jude Children's Research Hospital, Memphis, Tennessee, USA; Department of Pathology, St. Jude Children's Research Hospital, Memphis, Tennessee, USA.
| |
Collapse
|
25
|
Quaia E, Gennari AG, van Beek EJR. Differentiation of Inflammatory from Fibrotic Ileal Strictures among Patients with Crohn's Disease through Analysis of Time-Intensity Curves Obtained after Microbubble Contrast Agent Injection. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1171-1178. [PMID: 28385471 DOI: 10.1016/j.ultrasmedbio.2017.01.024] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Revised: 01/24/2017] [Accepted: 01/30/2017] [Indexed: 06/07/2023]
Abstract
The aim of the study described here was to assess whether the analysis of time-intensity curves obtained after microbubble contrast agent injection could differentiate inflammatory from fibrotic ileal strictures among patients with Crohn's disease. Sixty-five consecutive patients (40 male and 25 female; mean age ± SD, 42.2 ± 12.22 y) with stricture of the terminal ileal loop from Crohn's disease were scanned after microbubble injection. Time-intensity curves were obtained from quantitative analysis, and peak enhancement, rise time, time to peak, area under the time-intensity curve (AUC), AUC during wash-in (AUCWI) and AUC during wash-out (AUCWO) were compared between patients with inflammatory strictures and patients with fibrotic strictures. Inflammatory (n = 40) and fibrotic (n = 25) strictures differed (p < 0.05) in peak enhancement, wash-in rate, wash-in perfusion index, AUC, AUCWI and AUCWO. The quantitative analysis of small bowel wall contrast enhancement after microbubble contrast agent injection may differentiate inflammatory from fibrotic ileal strictures in patients with Crohn's disease.
Collapse
Affiliation(s)
- Emilio Quaia
- Edinburgh Imaging Facility, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, Scotland.
| | | | - Edwin J R van Beek
- Edinburgh Imaging Facility, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, Scotland
| |
Collapse
|
26
|
Rizzo G, Tonietto M, Castellaro M, Raffeiner B, Coran A, Fiocco U, Stramare R, Grisan E. Bayesian Quantification of Contrast-Enhanced Ultrasound Images With Adaptive Inclusion of an Irreversible Component. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:1027-1036. [PMID: 27959806 DOI: 10.1109/tmi.2016.2637698] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Contrast Enhanced Ultrasound (CEUS) is a sensitive imaging technique to assess tissue vascularity and it can be particularly useful in early detection and grading of arthritis. In a recent study we have shown that a Gamma-variate can accurately quantify synovial perfusion and it is flexible enough to describe many heterogeneous patterns. However, in some cases the heterogeneity of the kinetics can be such that even the Gamma model does not properly describe the curve, with a high number of outliers. In this work we apply to CEUS data the single compartment recirculation model (SCR) which takes explicitly into account the trapping of the microbubbles contrast agent by adding to the single Gamma-variate model its integral. The SCR model, originally proposed for dynamic-susceptibility magnetic resonance imaging, is solved here at pixel level within a Bayesian framework using Variational Bayes (VB). We also include the automatic relevant determination (ARD) algorithm to automatically infer the model complexity (SCR vs. Gamma model) from the data. We demonstrate that the inclusion of trapping best describes the CEUS patterns in 50% of the pixels, with the other 50% best fitted by a single Gamma. Such results highlight the necessity of the use ARD, to automatically exclude the irreversible component where not supported by the data. VB with ARD returns precise estimates in the majority of the kinetics (88% of total percentage of pixels) in a limited computational time (on average, 3.6 min per subject). Moreover, the impact of the additional trapping component has been evaluated for the differentiation of rheumatoid and non-rheumatoid patients, by means of a support vector machine classifier with backward feature selection. The results show that the trapping parameter is always present in the selected feature set, and improves the classification.
Collapse
|
27
|
Quaia E, Sozzi M, Angileri R, Gennari AG, Cova MA. Time-Intensity Curves Obtained after Microbubble Injection Can Be Used to Differentiate Responders from Nonresponders among Patients with Clinically Active Crohn Disease after 6 Weeks of Pharmacologic Treatment. Radiology 2016; 281:606-616. [DOI: 10.1148/radiol.2016152461] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
28
|
Turco S, Wijkstra H, Mischi M. Mathematical Models of Contrast Transport Kinetics for Cancer Diagnostic Imaging: A Review. IEEE Rev Biomed Eng 2016; 9:121-47. [PMID: 27337725 DOI: 10.1109/rbme.2016.2583541] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Angiogenesis plays a fundamental role in cancer growth and the formation of metastasis. Novel cancer therapies aimed at inhibiting angiogenic processes and/or disrupting angiogenic tumor vasculature are currently being developed and clinically tested. The need for earlier and improved cancer diagnosis, and for early evaluation and monitoring of therapeutic response to angiogenic treatment, have led to the development of several imaging methods for in vivo noninvasive assessment of angiogenesis. The combination of dynamic contrast-enhanced imaging with mathematical modeling of the contrast agent kinetics enables quantitative assessment of the structural and functional changes in the microvasculature that are associated with tumor angiogenesis. In this paper, we review quantitative imaging of angiogenesis with dynamic contrast-enhanced magnetic resonance imaging, computed tomography, and ultrasound.
Collapse
|
29
|
Atri M, Hudson JM, Sinaei M, Williams R, Milot L, Moshonov H, Burns PN, Bjarnason GA. Impact of Acquisition Method and Region of Interest Placement on Inter-observer Agreement and Measurement of Tumor Response to Targeted Therapy Using Dynamic Contrast-Enhanced Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:763-768. [PMID: 26712416 DOI: 10.1016/j.ultrasmedbio.2015.11.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2015] [Revised: 09/06/2015] [Accepted: 11/07/2015] [Indexed: 06/05/2023]
Abstract
This study evaluated the impact of different acquisition methods, user-directed region of interest placement and post-processing steps on the quantification of dynamic contrast-enhanced ultrasound measurements of blood volume in 29 patients with renal cancer, pre- and post-treatment. Specifically, we compared tumor quantification using multiple planes versus a single plane, breathhold versus free breathing and large region of interest versus a region targeting the area of highest vascularity. Performance was evaluated using area under the receiver operating characteristic curves to identify the method that best predicts progression-free survival. The intra-class correlation coefficient was also used to investigate how the same parameters affect inter-observer agreement. Of the different methods used to quantify blood volume in this study, the combination that had the highest level of inter-observer agreement (intra-class correlation coefficient = 0.8-0.97) and was the best predictor of progression-free survival was the change in blood volume measured (area under receiver operating characteristic curve = 0.77, p = 0.04) by a multiplane average, acquired during quiet breathing, quantified using a region of interest that encompassed the entire tumor.
Collapse
Affiliation(s)
- Mostafa Atri
- Division of Abdominal Imaging, Department of Medical Imaging, University of Toronto, Toronto General Hospital, Toronto, Ontario, Canada.
| | - John M Hudson
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada; Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Mehrdad Sinaei
- Division of Abdominal Imaging, Department of Medical Imaging, University of Toronto, Toronto General Hospital, Toronto, Ontario, Canada
| | - Ross Williams
- Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Laurent Milot
- Medical Imaging, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Hadas Moshonov
- Division of Abdominal Imaging, Department of Medical Imaging, University of Toronto, Toronto General Hospital, Toronto, Ontario, Canada
| | - Peter N Burns
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada; Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Georg A Bjarnason
- Medical Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario, Canada
| |
Collapse
|
30
|
Ackermann D, Schmitz G. Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:72-82. [PMID: 26595914 DOI: 10.1109/tuffc.2015.2500266] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
The imaging of microvessels and the quantification of their blood flow is of particular interest in the characterization of tumor vasculature. The imaging resolution (50-200 μm) of high-frequency ultrasound (US) (20-50 MHz) is not sufficient to image microvessels (~10 μm) and Doppler sensitivity is not high enough to measure capillary blood flow (~1 mm/s). For imaging of blood flow in microvessels, our approach is to detect single microbubbles (MBs), track them over several frames, and to estimate their velocity. First, positions of MBs will be detected by separating B-mode frames in a moving foreground and a static background. For the crucial task of association of these positions to tracks, we implemented a modified Markov chain Monte Carlo data association (MCMCDA) algorithm, which can handle a high number of MBs. False alarms, the detection, initiation, and termination of MBs tracks are incorporated in the underlying model. To test the performance of algorithms, a US imaging simulation of a vessel tree with flowing MBs was set up (resolution 148 μm). The trajectories and flow velocity in the vessels with a lateral distance of 100 μm were reconstructed with super-resolution. In a phantom experiment, a suspension of MBs was pumped through a tube (diameter 0.4 mm) at speeds of 2.2, 4.2, 6.3, and 10.5 mm/s and was imaged with a Vevo2100 system (Visualsonics). Estimated mean speeds of the MBs were 2.1, 4.7, 7, and 10.5 mm/s. To demonstrate the applicability for in vivo measurements, a tumor xenograft-bearing mouse was imaged by this approach. The tumor vasculature was visualized with higher resolution than in a maximum intensity persistence image and the velocity values were in the expected range 0-1 mm/s.
Collapse
|
31
|
Hudson JM, Williams R, Tremblay-Darveau C, Sheeran PS, Milot L, Bjarnason GA, Burns PN. Dynamic contrast enhanced ultrasound for therapy monitoring. Eur J Radiol 2015; 84:1650-7. [DOI: 10.1016/j.ejrad.2015.05.013] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2015] [Accepted: 05/10/2015] [Indexed: 11/17/2022]
|
32
|
Machtaler S, Knieling F, Luong R, Tian L, Willmann JK. Assessment of Inflammation in an Acute on Chronic Model of Inflammatory Bowel Disease with Ultrasound Molecular Imaging. Am J Cancer Res 2015; 5:1175-86. [PMID: 26379784 PMCID: PMC4568446 DOI: 10.7150/thno.13048] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2015] [Accepted: 07/16/2015] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Ultrasound (US) molecular imaging has shown promise in assessing inflammation in preclinical, murine models of inflammatory bowel disease. These models, however, initiated acute inflammation on previously normal colons, in contrast to patients where acute exacerbations are often in chronically inflamed regions. In this study, we explored the potential of dual P- and E-selectin targeted US imaging for assessing acute inflammation on a murine quiescent chronic inflammatory background. METHODS Chronic colitis was induced using three cycles of 4% DSS in male FVB mice. Acute inflammation was initiated 2 weeks after the final DSS cycle through rectal administration of 1% TNBS. Mice at different stages of inflammation were imaged using a small animal ultrasound system following i.v. injection of microbubbles targeted to P- and E-selectin. In vivo imaging results were correlated with ex vivo immunofluorescence and histology. RESULTS Induction of acute inflammation resulted in an increase in the targeted US signal from 5.5 ± 5.1 arbitrary units (a.u.) at day 0 to 61.0 ± 45.2 a.u. (P < 0.0001) at day 1, 36.3 ± 33.1 a.u. at day 3, returning to levels similar to control at day 5. Immunofluorescence showed significant increase in the percentage of P- and E-selectin positive vessels at day 1 (P-selectin: 21.0 ± 7.1% of vessels; P < 0.05; E-selectin: 16.4 ±3.7%; P < 0.05) compared to day 0 (P-selectin: 10.3 ± 5.7%; E-selectin: 7.3 ± 7.0%). CONCLUSIONS Acute inflammation can be accurately measured in a clinically relevant murine model of chronic IBD using ultrasound molecular imaging with a dual P- and E- selectin-targeted contrast agent.
Collapse
|
33
|
Paprottka PM, Roßpunt S, Ingrisch M, Cyran CC, Nikolaou K, Reiser MF, Mack B, Gires O, Clevert DA, Zengel P. Reducing tumor growth and angiogenesis using a triple therapy measured with Contrast-enhanced ultrasound (CEUS). BMC Cancer 2015; 15:373. [PMID: 25947947 PMCID: PMC4435644 DOI: 10.1186/s12885-015-1333-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Accepted: 04/22/2015] [Indexed: 11/10/2022] Open
Abstract
Background To evaluate the in vivo response by detecting the anti-angiogenic and invasion-inhibiting effects of a triple-combination-therapy in an experimental-small-animal-squamous-cell-carcinoma-model using the “flash-replenishment” (FR) method to assess tissue hemodynamics via contrast-enhanced-ultrasound (CEUS). Methods Human hypopharynx-carcinoma-cells were subcutaneously injected into the left flank of 22-female-athymic-nude-rats. After seven days of subcutaneous tumor growth, FR-measurements were performed on each rat. Treatment-group and control-group were treated every day for a period of one week, with the treatment-group receiving solvents containing a triple therapy of Upamostat®, Celecoxib® and Ilomastat® and the control-group solvents only. On day seven, follow-up measurements were performed using the same measurement protocol to assess the effects of the triple therapy. VueBox® was used to quantify the kinetic parameters and additional immunohistochemistry analyses were performed for comparison with and validation of the CEUS results against established methods (Proliferation/Ki-67, vascularization/CD31, apoptosis/caspase3). Results Compared to the control-group, the treatment-group that received the triple-therapy resulted in a reduction of tumor growth by 48.6% in size. Likewise, the immunohistochemistry results showed significant decreases in tumor proliferation and vascularization in the treatment-group in comparison to the control-group of 26%(p≤0.05) and 32.2%(p≤0.05) respectively. Correspondingly, between the baseline and follow-up measurements, the therapy-group was associated with a significant(p ≤ 0.01) decrease in the relative-Blood-Volume(rBV) in both the whole tumor(wt) and hypervascular tumor(ht) areas (p≤0.01), while the control-group was associated with a significant (p≤0.01) increase of the rBV in the wt area and a non-significant increase (p≤0.16) in the ht area. The mean-transit-time (mTT) of the wt and the ht areas showed a significant increase (p≤0.01) in the follow-up measurements in the therapy group. Conclusion The triple-therapy is feasible and effective in reducing both tumor growth and vascularization. In particular, compared with the placebo-group, the triple-therapy-group resulted in a reduction in tumor growth of 48.6% in size when assessed by CEUS and a significant reduction in the number of vessels in the tumor of 32% as assessed by immunohistochemistry. As the immunohistochemistry supports the CEUS findings, CEUS using the “flash replenishment”(FR) method appears to provide a useful assessment of the anti-angiogenic and invasion-inhibiting effects of a triple combination therapy.
Collapse
Affiliation(s)
| | - Svenja Roßpunt
- Institute for Ear, Nose and Throat Medicine, Ludwig Maximilian University Hospital, Munich, Germany.
| | - Michael Ingrisch
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany.
| | - Clemens C Cyran
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany.
| | - Konstantin Nikolaou
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany.
| | - Maximilian F Reiser
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany.
| | - Brigitte Mack
- Institute for Ear, Nose and Throat Medicine, Ludwig Maximilian University Hospital, Munich, Germany.
| | - Olivier Gires
- Institute for Ear, Nose and Throat Medicine, Ludwig Maximilian University Hospital, Munich, Germany.
| | - Dirk A Clevert
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany.
| | - Pamela Zengel
- Institute for Ear, Nose and Throat Medicine, Ludwig Maximilian University Hospital, Munich, Germany.
| |
Collapse
|
34
|
Daeichin V, Bosch JG, Needles A, Foster FS, van der Steen A, de Jong N. Subharmonic, non-linear fundamental and ultraharmonic imaging of microbubble contrast at high frequencies. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:486-97. [PMID: 25592458 DOI: 10.1016/j.ultrasmedbio.2014.10.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2013] [Revised: 09/11/2014] [Accepted: 10/08/2014] [Indexed: 05/24/2023]
Abstract
There is increasing use of ultrasound contrast agent in high-frequency ultrasound imaging. However, conventional contrast detection methods perform poorly at high frequencies. We performed systematic in vitro comparisons of subharmonic, non-linear fundamental and ultraharmonic imaging for different depths and ultrasound contrast agent concentrations (Vevo 2100 system with MS250 probe and MicroMarker ultrasound contrast agent, VisualSonics, Toronto, ON, Canada). We investigated 4-, 6- and 10-cycle bursts at three power levels with the following pulse sequences: B-mode, amplitude modulation, pulse inversion and combined pulse inversion/amplitude modulation. The contrast-to-tissue (CTR) and contrast-to-artifact (CAR) ratios were calculated. At a depth of 8 mm, subharmonic pulse-inversion imaging performed the best (CTR = 26 dB, CAR = 18 dB) and at 16 mm, non-linear amplitude modulation imaging was the best contrast imaging method (CTR = 10 dB). Ultraharmonic imaging did not result in acceptable CTRs and CARs. The best candidates from the in vitro study were tested in vivo in chicken embryo and mouse models, and the results were in a good agreement with the in vitro findings.
Collapse
Affiliation(s)
- Verya Daeichin
- Biomedical Engineering, Thorax Center, Erasmus MC, Rotterdam, The Netherlands.
| | - Johan G Bosch
- Biomedical Engineering, Thorax Center, Erasmus MC, Rotterdam, The Netherlands
| | | | - F Stuart Foster
- Sunnybrook Research Institute and Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Antonius van der Steen
- Biomedical Engineering, Thorax Center, Erasmus MC, Rotterdam, The Netherlands; Technical University Delft, Delft, The Netherlands
| | - Nico de Jong
- Biomedical Engineering, Thorax Center, Erasmus MC, Rotterdam, The Netherlands; Technical University Delft, Delft, The Netherlands; Interuniversity Cardiology Institute of the Netherlands, Utrecht, The Netherlands
| |
Collapse
|
35
|
Schneider AG, Goodwin MD, Schelleman A, Bailey M, Johnson L, Bellomo R. Contrast-enhanced ultrasonography to evaluate changes in renal cortical microcirculation induced by noradrenaline: a pilot study. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2014; 18:653. [PMID: 25439317 PMCID: PMC4262130 DOI: 10.1186/s13054-014-0653-3] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2014] [Accepted: 11/10/2014] [Indexed: 01/01/2023]
Abstract
Introduction We used contrast-enhanced ultrasound (CEUS) to estimate the effect of an increase in mean arterial pressure (MAP) induced by noradrenaline infusion on renal microvascular cortical perfusion in critically ill patients. Methods Twelve patients requiring a noradrenaline infusion to maintain a MAP more than 60 mmHg within 48 hours of intensive care unit admission were included in the study. Renal CEUS scans with destruction-replenishment sequences and Sonovue® (Bracco, Milano Italy) as a contrast agent, were performed at baseline (MAP 60 to 65 mmHg) and after a noradrenaline-induced increase in MAP to 80 to 85 mmHg. Results There was no adverse effect associated with ultrasound contrast agent administration or increase in noradrenaline infusion rate. Adequate images were obtained in all patients at all study times. To reach the higher MAP target, median noradrenaline infusion rate was increased from 10 to 14 μg/min. Noradrenaline-induced increases in MAP were not associated with a significant change in overall CEUS derived mean perfusion indices (median perfusion index 3056 (interquartile range: 2438 to 6771) arbitrary units (a.u.) at baseline versus 4101 (3067 to 5981) a.u. after MAP increase, P = 0.38). At individual level, however, we observed important heterogeneity in responses (range -51% to +97% changes from baseline). Conclusions A noradrenaline-induced increase in MAP was not associated with an overall increase in renal cortical perfusion as estimated by CEUS. However, at individual level, such response was heterogeneous and unpredictable suggesting great variability in pressure responsiveness within a cohort with a similar clinical phenotype. Electronic supplementary material The online version of this article (doi:10.1186/s13054-014-0653-3) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Antoine G Schneider
- Intensive Care Unit, Austin Health, 145 Studley road, Heidelberg, VIC, 3084, Australia. .,Australian and New Zealand Intensive Care Research Centre, School of Public Health and Preventive Medicine, Monash University, Melbourne, VIC, Australia.
| | - Mark D Goodwin
- Radiology department, Austin Health, Heidelberg, VIC, Australia.
| | | | - Michael Bailey
- Australian and New Zealand Intensive Care Research Centre, School of Public Health and Preventive Medicine, Monash University, Melbourne, VIC, Australia.
| | - Lynne Johnson
- Radiology department, Austin Health, Heidelberg, VIC, Australia.
| | - Rinaldo Bellomo
- Intensive Care Unit, Austin Health, 145 Studley road, Heidelberg, VIC, 3084, Australia. .,Australian and New Zealand Intensive Care Research Centre, School of Public Health and Preventive Medicine, Monash University, Melbourne, VIC, Australia. .,Faculty of Medicine, University of Melbourne, Melbourne, VIC, Australia.
| |
Collapse
|
36
|
Schneider AG, Calzavacca P, Schelleman A, Huynh T, Bailey M, May C, Bellomo R. Contrast-enhanced ultrasound evaluation of renal microcirculation in sheep. Intensive Care Med Exp 2014; 2:33. [PMID: 26266930 PMCID: PMC4513025 DOI: 10.1186/s40635-014-0033-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2014] [Accepted: 11/16/2014] [Indexed: 12/29/2022] Open
Abstract
Background Contrast-enhanced ultrasonography (CEUS) is a novel imaging modality to estimate microvascular perfusion. We aimed to assess renal cortical microcirculatory changes by CEUS during pharmacologically or mechanically induced modifications of renal blood flow (RBF) in experimental animals. Methods We implanted invasive transit-time Doppler flow probes and a vascular occluder around the renal artery in six Merino sheep. After induction of general anaesthesia, renal CEUS studies with destruction-replenishment sequences were performed at baseline and after different interventions aimed at modifying RBF. First, we administered angiotensin II (AngII) to achieve a 25% (AngII 25%) and 50% (AngII 50%) decrease in RBF. Then, we applied mechanical occlusion of the renal artery until RBF decreased by 25% (Occl 25%) and 50% (Occl 50%) of the baseline. Finally, a single dose of 25 mg of captopril was administered. CEUS sequences were analysed offline with dedicated software and perfusion indices (PI) calculated. Results Pharmacological reduction of RBF with AngII was associated with a 62% (range: 68 decrease to 167 increase) increase (AngII 25%) and a 5% increase in PI (range: 92% decrease to 53% increase) (AngII 50%) in PI. Mechanical occlusion of the renal artery was associated with a 2% (range: 43% decrease to 2% increase) decrease (Occl 25%) and a 67% (range: 63% decrease to a 120% increase) increase (Occl 50%) in PI. The administration of captopril was associated with a 8% (range: 25% decrease to a 101% increase) decrease in PI. Pooled changes in PI failed to reach statistical significance. The study was limited by the difficulty to obtain high quality images. Conclusions CEUS-derived parameters were highly heterogeneous in this sheep model. The current protocol and model did not allow the evaluation of the correlation between macro and microcirculation assessment by CEUS.
Collapse
Affiliation(s)
- Antoine G Schneider
- Intensive Care Unit, Austin Health, Austin Health, 145 Studley Road, Heidelberg, Victoria, 3084, Australia,
| | | | | | | | | | | | | |
Collapse
|
37
|
Schneider AG, Schelleman A, Goodwin MD, Bailey M, Eastwood GM, Bellomo R. Contrast-enhanced ultrasound evaluation of the renal microcirculation response to terlipressin in hepato-renal syndrome: a preliminary report. Ren Fail 2014; 37:175-9. [PMID: 25365636 DOI: 10.3109/0886022x.2014.977140] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
BACKGROUND Terlipressin improves renal function in some patients with type-1 hepato-renal syndrome (HRS). Renal contrast-enhanced ultrasound (CEUS), a novel imaging modality, may help to predict terlipressin responsiveness. OBJECTIVES We used CEUS to estimate the effect of terlipressin on the renal cortical microcirculation in type-1 HRS. METHODS We performed renal CEUS scans with destruction-replenishment sequences using Sonovue(®) (Bracco, Milano Italy) as a contrast agent at baseline and after the intravenous administration of 1 mg of terlipressin, in four patients with type-1 HRS. We analyzed video sequences offline using dedicated software. We derived a perfusion index (PI) at each time point for each patient. RESULTS Patients 1 and 2 had severe presentation and were admitted to the intensive care unit. Both showed a marked increase in PI (+216% and + 567% of baseline) in response to terlipressin. Patients 3 and 4 had less severe presentations and had a decrease in PI (-53% and -20% of baseline) in response to terlipressin. Patients 1, 2, and 4, but not patient 3, responded to terlipressin therapy with a decrease in serum creatinine to <150 µmol/L. CONCLUSIONS CEUS detected changes in renal cortical microcirculation in response to terlipressin and demonstrated heterogeneous microvascular responses to terlipressin. These initial proof-of-concept findings justify future investigations.
Collapse
|
38
|
Hudson JM, Williams R, Karshafian R, Milot L, Atri M, Burns PN, Bjarnason GA. Quantifying vascular heterogeneity using microbubble disruption-replenishment kinetics in patients with renal cell cancer. Invest Radiol 2014; 49:116-23. [PMID: 24220251 DOI: 10.1097/rli.0000000000000003] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
PURPOSE The purposes of this study were to establish the physiological interpretation of the shape parameter of the dynamic contrast-enhanced ultrasound (DCE-US) lognormal perfusion model and to evaluate the clinical significance of the parameter in a sample of patients undergoing antiangiogenic therapy for metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS The physiological interpretation of the lognormal shape parameter was explored using computer simulations of disruption-replenishment in fractal models of the microcirculation generated by a piecewise iterative algorithm in MATLAB. Architectural variety was accomplished by introducing random perturbations to the diameter, length, and branching angles to the growing vascular tree. The shape parameter was extracted from the time-intensity curves and compared with the transit time distributions calculated directly from the simulations. Dynamic contrast-enhanced ultrasound data were obtained from 31 consenting patients with mRCC being treated with antiangiogenic therapy. Lognormal parameters related to the blood volume, mean flow speed, and vascular morphology/heterogeneity extracted before, during, and after therapy were correlated with progression-free survival (PFS). Cox proportional hazard ratios were calculated alongside receiver operator characteristics for different combinations of the vascular parameters to determine their ability to distinguish patients who would progress early (less than the median PFS) versus late (greater than the median PFS). RESULTS The lognormal shape parameter correlated strongly to the width of the transit time distribution calculated directly from the simulations, and by extension, to the morphology/heterogeneity of the microvascular network (Spearman r = 0.80, P < 0.001, n = 28). Shorter time to progression was predicted by higher baseline heterogeneity (P = 0.003) and a reduction in tumor blood volume less than 43% (P = 0.002) after 2 weeks of treatment. Combining baseline parameters with changes that occur shortly after starting treatment increased the sensitivity and specificity of DCE-US to identify which patients would progress/resist therapy early versus late compared with when the vascular parameters were considered in isolation. CONCLUSIONS The DCE-US shape parameter from the lognormal perfusion model is representative of microvascular morphology/heterogeneity and may be used to noninvasively characterize the vascular architecture of cancer lesions. A more abnormal flow distribution at baseline predicts for poorer outcome for patients treated with antiangiogenic therapy for metastatic renal cell cancer. Combining pretreatment and on-treatment measurements of vascularity can improve the performance of DCE-US to predict which patients will progress earlier versus later when on antiangiogenic therapy for mRCC.
Collapse
Affiliation(s)
- John M Hudson
- From the *Department of Medical Biophysics, University of Toronto; †Imaging Research, Sunnybrook Research Institute; ‡Department of Physics, Ryerson University; §Medical Imaging, Sunnybrook Health Sciences Centre; ∥Department of Medical Imaging, Toronto General Hospital; and ¶Medical Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario, Canada
| | | | | | | | | | | | | |
Collapse
|
39
|
Fan CH, Lin WH, Ting CY, Chai WY, Yen TC, Liu HL, Yeh CK. Contrast-enhanced ultrasound imaging for the detection of focused ultrasound-induced blood-brain barrier opening. Theranostics 2014; 4:1014-25. [PMID: 25161701 PMCID: PMC4143942 DOI: 10.7150/thno.9575] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2014] [Accepted: 07/10/2014] [Indexed: 01/08/2023] Open
Abstract
The blood-brain barrier (BBB) can be transiently and locally opened by focused ultrasound (FUS) in the presence of microbubbles (MBs). Various imaging modalities and contrast agents have been used to monitor this process. Unfortunately, direct ultrasound imaging of BBB opening with MBs as contrast agent is not feasible, due to the inability of MBs to penetrate brain parenchyma. However, FUS-induced BBB opening is accompanied by changes in blood flow and perfusion, suggesting the possibility of perfusion-based ultrasound imaging. Here we evaluated the use of MB destruction-replenishment, which was originally developed for analysis of ultrasound perfusion kinetics, for verifying and quantifying FUS-induced BBB opening. MBs were intravenously injected and the BBB was disrupted by 2 MHz FUS with burst-tone exposure at 0.5-0.7 MPa. A perfusion kinetic map was estimated by MB destruction-replenishment time-intensity curve analysis. Our results showed that the scale and distribution of FUS-induced BBB opening could be determined at high resolution by ultrasound perfusion kinetic analysis. The accuracy and sensitivity of this approach was validated by dynamic contrast-enhanced MRI. Our successful demonstration of ultrasound imaging to monitor FUS-induced BBB opening provides a new approach to assess FUS-dependent brain drug delivery, with the benefit of high temporal resolution and convenient integration with the FUS device.
Collapse
|
40
|
Sugimoto K, Moriyasu F, Saito K, Yoshiara H, Imai Y. Kupffer-phase findings of hepatic hemangiomas in contrast-enhanced ultrasound with sonazoid. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:1089-1095. [PMID: 24556559 DOI: 10.1016/j.ultrasmedbio.2013.12.019] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2013] [Revised: 11/12/2013] [Accepted: 12/12/2013] [Indexed: 06/03/2023]
Abstract
The aim of this study was to assess quantitatively the Kupffer-phase enhancement patterns of hepatic hemangiomas in contrast-enhanced ultrasound (CEUS) with Sonazoid. A total of 46 patients with 46 hepatic hemangiomas (17.1 ± 6.2 mm in diameter, 34 typical type and 12 high-flow type) underwent CEUS in the Kupffer phase. The lesion-to-liver contrast ratio in the Kupffer phase was quantitatively assessed for both types of hemangioma. Most of the hepatic hemangiomas, whether or not they were the high-flow type, were iso- to hypo-echoic relative to the surrounding liver parenchyma. The contrast ratio was -5.33 ± 6.70 dB for the high-flow hemangiomas and -4.54 ± 6.28 dB for the typical hemangiomas. There was no significant difference in contrast ratio between the two types of lesions (p = 0.73). All of the hemangiomas, whether of typical or high-flow type, are iso- to hypo-echoic relative to the surrounding liver parenchyma on Kupffer-phase imaging.
Collapse
Affiliation(s)
- Katsutoshi Sugimoto
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan.
| | - Fuminori Moriyasu
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Kazuhiro Saito
- Department of Radiology, Tokyo Medical University, Tokyo, Japan
| | - Hiroki Yoshiara
- Ultrasound Division, Toshiba Medical Systems Corporation, Tochigi, Japan
| | - Yasuharu Imai
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| |
Collapse
|
41
|
Guo C, Jin Y, Dai Z. Multifunctional Ultrasound Contrast Agents for Imaging Guided Photothermal Therapy. Bioconjug Chem 2014; 25:840-54. [DOI: 10.1021/bc500092h] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Caixin Guo
- School
of Life Science and Technology, Harbin Institute of Technology, Harbin 150080, China
| | - Yushen Jin
- School
of Life Science and Technology, Harbin Institute of Technology, Harbin 150080, China
- Department
of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871, China
| | - Zhifei Dai
- Department
of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871, China
| |
Collapse
|
42
|
Saini R, Hoyt K. Recent developments in dynamic contrast-enhanced ultrasound imaging of tumor angiogenesis. ACTA ACUST UNITED AC 2014; 6:41-52. [PMID: 25221623 DOI: 10.2217/iim.13.74] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Angiogenesis is a critical process for tumor growth and metastatic dissemination. There is tremendous interest in the development of noninvasive methods for imaging tumor angiogenesis, and ultrasound (US) is an emerging platform technology to address this challenge. The introduction of intravascular microbubble contrast agents not only allows real-time visualization of tumor perfusion during an US examination, but they can be functionalized with specific ligands to permit molecular US imaging of angiogenic biomarkers that are overexpressed on the tumor endothelium. In this article, we will review current concepts and developing trends for US imaging of tumor angiogenesis, including relevant preclinical and clinicsal findings.
Collapse
Affiliation(s)
- Reshu Saini
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA ; Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Kenneth Hoyt
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA ; Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL, USA ; Electrical & Computer Engineering, University of Alabama at Birmingham, Birmingham, AL, USA ; Comprehensive Cancer Center, University of Alabama at Birmingham, Volker Hall G082, 1670 University Boulevard, Birmingham, AL 35294, USA
| |
Collapse
|
43
|
Kuenen MPJ, Saidov TA, Wijkstra H, de la Rosette JJMCH, Mischi M. Spatiotemporal correlation of ultrasound contrast agent dilution curves for angiogenesis localization by dispersion imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:2665-2669. [PMID: 24297031 DOI: 10.1109/tuffc.2013.2865] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The major role of angiogenesis in cancer development has driven many researchers to investigate the prospects of noninvasive cancer imaging based on assessment of microvascular perfusion. The limited results so far may be caused by the complex and contradictory effects of angiogenesis on perfusion. Alternatively, assessment of ultrasound contrast agent dispersion kinetics, resulting from features such as density and tortuosity, has shown a promising potential to characterize angiogenic effects on the microvascular structure. This method, referred to as contrast-ultrasound dispersion imaging (CUDI), is based on contrast-enhanced ultrasound imaging after an intravenous contrast agent bolus injection. In this paper, we propose a new spatiotemporal correlation analysis to perform CUDI. We provide the rationale for indirect estimation of local dispersion by deriving the analytical relation between dispersion and the correlation coefficient among neighboring time-intensity curves obtained at each pixel. This robust analysis is inherently normalized and does not require curve-fitting. In a preliminary validation of the method for localization of prostate cancer, the results of this analysis show superior cancer localization performance (receiver operating characteristic curve area of 0.89) compared with those of previously reported CUDI implementations and perfusion estimation methods.
Collapse
|
44
|
|
45
|
Barrois G, Coron A, Payen T, Dizeux A, Bridal L. A multiplicative model for improving microvascular flow estimation in dynamic contrast-enhanced ultrasound (DCE-US): theory and experimental validation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:2284-2294. [PMID: 24158285 DOI: 10.1109/tuffc.2013.6644733] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Perfusion parameter estimation from dynamic contrast-enhanced ultrasound (DCE-US) data relies on fitting parametric models of flow to curves describing linear echo power as a function of time. The least squares criterion is generally used to fit these models to data. This criterion is optimal in the sense of maximum likelihood under the assumption of an additive white Gaussian noise. In the current work, it is demonstrated that this assumption is not held for DCEUS. A better-adapted maximum likelihood criterion based on a multiplicative model is proposed. It is tested on simulated bolus perfusion data and on 11 sequences acquired in vivo during bolus perfusion of contrast agent in the cortex of healthy murine kidney, an area where the perfusion is expected to be approximately homogeneous. Results on simulated data show a significant improvement (p < 0.05) of the precision and the accuracy for the estimations of perfusion parameters time to peak (TTP), wash-in rate (WiR), and mean transit time (MTT). On the 11 in vivo sequences, the new method leads to a significant reduction (p < 0.05) in the variation of parametric maps for 9 sequences for TTP and 10 sequences for WiR and MTT. The mean percent decreases of the coefficient of variation are 40%, 25%, and 59% for TTP, WiR, and MTT, respectively. This method should contribute to a more robust and accurate estimation of perfusion parameters and an improved resolution of parametric imaging.
Collapse
|
46
|
Payen T, Coron A, Lamuraglia M, Le Guillou-Buffello D, Gaud E, Arditi M, Lucidarme O, Bridal SL. Echo-power estimation from log-compressed video data in dynamic contrast-enhanced ultrasound imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1826-1837. [PMID: 23879926 DOI: 10.1016/j.ultrasmedbio.2013.03.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2012] [Revised: 03/20/2013] [Accepted: 03/21/2013] [Indexed: 06/02/2023]
Abstract
Ultrasound (US) scanners typically apply lossy, non-linear modifications to the US data for visualization purposes. The resulting images are then stored as compressed video data. Some system manufacturers provide dedicated software for quantification purposes to eliminate such processing distortions, at least partially. This is currently the recommended approach for quantitatively assessing changes in contrast-agent concentration from clinical data. However, the machine-specific access to US data and the limited set of analysis functionalities offered by each dedicated-software package make it difficult to perform comparable analyses with different US systems. The objective of this work was to establish if linearization of compressed video images obtained with an arbitrary US system can provide an alternative to dedicated-software analysis of machine-specific files for the estimation of echo-power. For this purpose, an Aplio 50 system (Toshiba Medical Systems, Tochigi, Japan), coupled with dedicated CHI-Q (Contrast Harmonic Imaging Quantification) software by Toshiba Medical Systems, was used. Results were compared with two approaches that apply algorithms to estimate relative echo-power from compressed video images: commercially available VueBox software by Bracco Suisse SA (Geneva, Switzerland) and in-laboratory software called PixPower. The echo-power estimated by CHI-Q analysis indicated a strong linear relationship versus agent concentration in vitro (R(2) ≥ 0.9996) for dynamic range (DR) settings of DR60 and DR80, with slopes between 9.22 and 9.57 dB/decade (p = 0.05). These values approach the theoretically predicted dependence of 10.0 dB/decade (equivalent to 3 dB for each concentration doubling). Echo-power estimations obtained from compressed video images with VueBox and PixPower also exhibited strong linear proportionality with concentration (R(2) ≥ 0.9996), with slopes between 9.30 and 9.68 dB/decade (p = 0.05). On an independent in vivo data set (N = 24), the difference in echo-power estimation between CHI-Q and each of the other two approaches was calculated after excluding regions that contain pixels affected by saturated or thresholded pixel values. The mean difference in estimates (expressed in decibels) was -0.25 dB between VueBox and CHI-Q (95% confidence interval: -0.75 to 0.26 dB) and -0.17 dB between PixPower and CHI-Q (95% confidence interval: -0.67 to 0.13 dB). To achieve linearization of data, one of the approaches (VueBox) requires calibration files provided by the software manufacturer for each machine type and setting. The other (PixPower) requires empirical correction of the imaging dynamic range based on ground truth data. These requirements could potentially be removed if US system manufacturers were willing to make relevant information on the applied processing publically available. Reliable echo-power estimation from linearized data would facilitate inclusion of different US systems in multicentric studies and more widespread implementation of emerging techniques for quantitative analysis of contrast ultrasound.
Collapse
|
47
|
Declèves AE, Rychak JJ, Smith DJ, Sharma K. Effects of high-fat diet and losartan on renal cortical blood flow using contrast ultrasound imaging. Am J Physiol Renal Physiol 2013; 305:F1343-51. [PMID: 24049144 DOI: 10.1152/ajprenal.00326.2013] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Obesity-related kidney disease occurs as a result of complex interactions between metabolic and hemodynamic effects. Changes in microvascular perfusion may play a major role in kidney disease; however, these changes are difficult to assess in vivo. Here, we used perfusion ultrasound imaging to evaluate cortical blood flow in a mouse model of high-fat diet-induced kidney disease. C57BL/6J mice were randomized to a standard diet (STD) or a high-fat diet (HFD) for 30 wk and then treated either with losartan or a placebo for an additional 6 wk. Noninvasive ultrasound perfusion imaging of the kidney was performed during infusion of a microbubble contrast agent. Blood flow within the microvasculature of the renal cortex and medulla was derived from imaging data. An increase in the time required to achieve full cortical perfusion was observed for HFD mice relative to STD. This was reversed following treatment with losartan. These data were concurrent with an increased glomerular filtration rate in HFD mice compared with STD- or HFD-losartan-treated mice. Losartan treatment also abrogated fibro-inflammatory disease, assessed by markers at the protein and messenger level. Finally, a reduction in capillary density was found in HFD mice, and this was reversed upon losartan treatment. This suggests that alterations in vascular density may be responsible for the elevated perfusion time observed by imaging. These data demonstrate that ultrasound contrast imaging is a robust and sensitive method for evaluating changes in renal microvascular perfusion and that cortical perfusion time may be a useful parameter for evaluating obesity-related renal disease.
Collapse
Affiliation(s)
- Anne-Emilie Declèves
- Center for Renal Translational Medicine, Division of Nephrology-Hypertension, 405 Stein Clinical Research Bldg., MC 0711, Univ. of California San Diego, La Jolla, CA, 92093.
| | | | | | | |
Collapse
|
48
|
Kuenen MPJ, Saidov TA, Wijkstra H, Mischi M. Contrast-ultrasound dispersion imaging for prostate cancer localization by improved spatiotemporal similarity analysis. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1631-41. [PMID: 23791350 DOI: 10.1016/j.ultrasmedbio.2013.03.004] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2012] [Revised: 01/18/2013] [Accepted: 03/05/2013] [Indexed: 05/14/2023]
Abstract
Angiogenesis plays a major role in prostate cancer growth. Despite extensive research on blood perfusion imaging aimed at angiogenesis detection, the diagnosis of prostate cancer still requires systematic biopsies. This may be due to the complex relationship between angiogenesis and microvascular perfusion. Analysis of ultrasound-contrast-agent dispersion kinetics, determined by multipath trajectories in the microcirculation, may provide better characterization of the microvascular architecture. We propose the physical rationale for dispersion estimation by an existing spatiotemporal similarity analysis. After an intravenous ultrasound-contrast-agent bolus injection, dispersion is estimated by coherence analysis among time-intensity curves measured at neighbor pixels. The accuracy of the method is increased by time-domain windowing and anisotropic spatial filtering for speckle regularization. The results in 12 patient data sets indicated superior agreement with histology (receiver operating characteristic curve area = 0.88) compared with those obtained by reported perfusion and dispersion analyses, providing a valuable contribution to prostate cancer localization.
Collapse
Affiliation(s)
- M P J Kuenen
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | | | | | | |
Collapse
|
49
|
|
50
|
Schneider AG, Goodwin MD, Schelleman A, Bailey M, Johnson L, Bellomo R. Contrast-enhanced ultrasound to evaluate changes in renal cortical perfusion around cardiac surgery: a pilot study. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2013; 17:R138. [PMID: 23849270 PMCID: PMC4056320 DOI: 10.1186/cc12817] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Accepted: 07/12/2013] [Indexed: 01/18/2023]
Abstract
Introduction Contrast-enhanced ultrasound (CEUS) is a new technique that might enable portable and non-invasive organ perfusion quantification at the bedside. However, it has not yet been tested in critically ill patients. We sought to establish CEUS's feasibility, safety, reproducibility and potential diagnostic value in the assessment of renal cortical perfusion in the peri-operative period in cardiac surgery patients. Methods We recruited twelve patients deemed at risk of acute kidney injury (AKI) planned for elective cardiac surgery. We performed renal CEUS with destruction-replenishment sequences before the operation, on ICU arrival and the day following the admission. Enhancement was obtained with Sonovue® (Bracco, Milano, Italy) at an infusion rate of 1 ml/min. We collected hemodynamic parameters before, during and after contrast agent infusion. At each study time, we obtained five video sequences, which were analysed using dedicated software by two independent radiologists blinded to patient and time. The main output was a perfusion index (PI), corresponding to the ratio of relative blood volume (RBV) over mean transit time (mTT). Results All 36 renal CEUS studies, including 24 in the immediate post-operative period could be performed and were well tolerated. Correlation between readers for PI was excellent (R2 = 0.96, P < 0.0001). Compared with baseline, there was no overall difference in median PI's on ICU admission. However, the day after surgery, median PI's had decreased by 50% (P < 0.01) (22% decrease in RBV (P = 0.09); 48% increase in mTT (P = 0.04), both suggestive of decreased perfusion). These differences persisted after correction for haemoglobin; vasopressors use and mean arterial pressure. Four patients developed AKI in the post-operative period. Conclusions CEUS appears feasible and well-tolerated in patients undergoing cardiac surgery even immediately after ICU admission. CEUS derived-parameters suggest a decrease in renal perfusion occurring within 24 hours of surgery.
Collapse
|