1
|
Ruiz Henao PA, Magrin GL, Caneiro-Queija L, Benfatti CAM, Leira Y, Liñares-González A, Blanco-Carrión J. Single-piece zirconia versus single-piece titanium, narrow-diameter dental implants in the anterior maxilla: 5-year post-loading results of a randomized clinical trial. Clin Oral Implants Res 2024; 35:1310-1323. [PMID: 38940623 DOI: 10.1111/clr.14319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 05/20/2024] [Accepted: 06/02/2024] [Indexed: 06/29/2024]
Abstract
OBJECTIVES The aim of this study was to evaluate esthetic parameters in the anterior maxillary region by comparing single-piece zirconia versus titanium narrow-diameter implants. Additionally, clinical, radiological and patient-reported outcome measures (PROMs) were analyzed. MATERIALS AND METHODS Thirty implants (tissue level implant) were placed in 30 patients in the maxillary esthetic sector. Depending on randomization, a zirconia (test) or titanium implant (control) was placed. Esthetic, clinical, and radiological parameters, including the implant crown esthetic index (ICAI), pink esthetic score (PES), probing pocket depth, bleeding on probing, plaque index, and marginal bone levels, were evaluated at 12, 36 and 60 months after loading. RESULTS Sixty months after crown placement, no significant differences were found between groups. The ICAI values were 5.25 ± 4.21 and 4.50 ± 2.98 for the test and control groups, respectively. The corresponding PES values were 7.44 ± 1.93 and 7.43 ± 1.74 for the test and control groups, respectively. There were no significant intergroup differences for the rest of the parameters evaluated. CONCLUSION It can be suggested that monotype zirconia implants may serve as a potential alternative to titanium implants in selected clinical scenarios. While the results demonstrated comparable esthetic, clinical, and radiological aspects for zirconia implants as compared to titanium implants after a 5-year follow-up period, further research with larger sample sizes and longer-term follow-up is recommended.
Collapse
Affiliation(s)
- Paula Andrea Ruiz Henao
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Gabriel Leonardo Magrin
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
- Center for Education and Research on Dental Implants (CEPID), Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Leticia Caneiro-Queija
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Cesar Augusto Magalhães Benfatti
- Center for Education and Research on Dental Implants (CEPID), Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Yago Leira
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Antonio Liñares-González
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Juan Blanco-Carrión
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| |
Collapse
|
2
|
Morena D, Leitão-Almeida B, Pereira M, Resende R, Fernandes JCH, Fernandes GVO, Borges T. Comparative Clinical Behavior of Zirconia versus Titanium Dental Implants: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. J Clin Med 2024; 13:4488. [PMID: 39124755 PMCID: PMC11313197 DOI: 10.3390/jcm13154488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2024] [Revised: 07/26/2024] [Accepted: 07/29/2024] [Indexed: 08/12/2024] Open
Abstract
Objective: The goal of this systematic review and meta-analysis was to assess whether there were clinically relevant differences in the treatment of edentulous areas comparing zirconia (Zr) and titanium (Ti) dental implants. The null hypothesis is that no differences can be observed in terms of the clinical parameters; the positive hypothesis I is that Zr implants have generally better results compared to Ti implants; and the positive hypothesis II is that Ti implants have a generally superior result than Zr implants. Methods: This review work was registered on the PROSPERO platform, and its development was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. The electronic search process was conducted on three databases (PubMed/Scopus/Web of Science), including randomized controlled trials (RCTs) from the past 10 years (up to April 2024). Identified articles were analyzed and included/excluded based on pre-defined selection and exclusion criteria. The quality assessment and risk of bias were evaluated using a Cochrane risk-of-bias assessment tool specifically designed for randomized trials (RoB2). A meta-analysis was conducted to correlate different treatment options based on the described outcomes; a random-effects model was used in the analysis of the variables. The analysis of heterogeneity was conducted by means of Cochran's Q-test and Higgins' I2 statistic. Results: Six RCTs were enrolled; 152 patients (90 males and 62 females) and 448 implants (267 Zr and 181 Ti) were included. Dental implant placement involved both the maxillary and mandibular arches. The implant sites showed heterogeneity in receiving Zr and Ti dental implants; in particular, 22 dental implants were placed in the mid-palatal region and 426 dental implants in the alveolar region (255 were in Zr and 171 in Ti). Regarding the success rate, it was better for Zr but with no statistical difference (p > 0.05); bleeding on probing had slight differences between Ti with 0.34% ± 0.42 and Zr with 0.26% ± 0.36 (p > 0.05); plaque score showed 0.46 ± 0.47 for Ti compared to 0.44 ± 0.49 for Zr (p > 0.05); no statistically significant difference was observed for pink esthetic score (PES). Statistically significant results were found for survival rate, which favored Ti implants (77.6%) compared to Zr (70.3%) (p < 0.05), and for marginal bone loss, which showed less loss in Ti implants (0.18 mm ± 0.47) compared to 0.42 mm ± 0.40 in Zr at 12 months (p < 0.001). Conclusions: The present systematic review and meta-analysis identified the positive hypothesis I and rejected the null and positive hypothesis II; it was possible to conclude that Ti dental implants have a better survival rate and less marginal bone loss than Zr dental implants after 1-year follow-up.
Collapse
Affiliation(s)
- Danilo Morena
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| | - Bruno Leitão-Almeida
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
- Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| | - Miguel Pereira
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
- Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| | - Rodrigo Resende
- Faculty of Dentistry, Fluminense Federal University, Niterói, RJ 24220-140, Brazil
| | | | - Gustavo Vicentis Oliveira Fernandes
- Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
- Missouri School of Dentistry and Oral Health, A. T. Still University, St. Louis, MO 63104, USA
| | - Tiago Borges
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
- Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| |
Collapse
|
3
|
Mohseni P, Soufi A, Chrcanovic BR. Clinical outcomes of zirconia implants: a systematic review and meta-analysis. Clin Oral Investig 2023; 28:15. [PMID: 38135804 PMCID: PMC10746607 DOI: 10.1007/s00784-023-05401-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 12/04/2023] [Indexed: 12/24/2023]
Abstract
PURPOSE To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. METHODS An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done. RESULTS Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up. CONCLUSION Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055). CLINICAL RELEVANCE The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Collapse
Affiliation(s)
| | - Ahmad Soufi
- Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Bruno Ramos Chrcanovic
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Carl Gustafs Väg 34, 214 21, Malmö, Sweden.
| |
Collapse
|
4
|
Watanabe M, Liu L, Ichikawa T. Are Allergy-Induced Implant Failures Actually Hypersensitivity Reactions to Titanium? A Literature Review. Dent J (Basel) 2023; 11:263. [PMID: 37999027 PMCID: PMC10670842 DOI: 10.3390/dj11110263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 11/02/2023] [Accepted: 11/08/2023] [Indexed: 11/25/2023] Open
Abstract
PURPOSE This literature review was performed to assess whether implant failures are associated with titanium allergy. MATERIALS AND METHODS An electronic search of the MEDLINE/PubMed, Cochrane Library, and Scopus databases up to April 2021 was conducted, and the obtained articles were independently assessed by two reviewers. Articles describing cases of implant failure in which the cause of implant failure was only identified as allergy were included. RESULTS Twelve studies were included. Eight studies identified Ti allergy by clinical examinations, of which four used patch tests, three used the lymphocyte transformation test (LTT)/memory lymphocyte immunostimulation assay (MELISA), and one used both tests. Nine studies reported cases of titanium hypersensitivity in combination with other systemic allergy-related disorders, with eight cases also showing positive results for Ni, Hg, Cr, and Co hypersensitivity. Ten papers reported the improvement of symptoms after the removal of the Ti implants and their replacement with zirconia implants, and two of these papers showed good results. CONCLUSION Cases of probable titanium allergy included those with true titanium allergies and those with a potentially different cause. However, the differentiation of these cases is difficult. Since no definitive method has been established for diagnosing titanium allergy, a comprehensive diagnosis based on the clinical course and clinical examination using a patch test/LTT/MELISA is necessary. Implant treatment should be performed with caution in patients with any preoperative allergies.
Collapse
Affiliation(s)
- Megumi Watanabe
- Department of Prosthodontics & Oral Rehabilitation, Tokushima University, Graduate School of Biomedical Sciences, 3-18-15, Kuramoto, Tokushima 770-8504, Japan; (L.L.); (T.I.)
| | | | | |
Collapse
|
5
|
Padhye NM, Calciolari E, Zuercher AN, Tagliaferri S, Donos N. Survival and success of zirconia compared with titanium implants: a systematic review and meta-analysis. Clin Oral Investig 2023; 27:6279-6290. [PMID: 37740825 PMCID: PMC10630218 DOI: 10.1007/s00784-023-05242-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 09/05/2023] [Indexed: 09/25/2023]
Abstract
OBJECTIVE This systematic review assessed the available evidence on the survival and success rate of zirconia and titanium implants. As secondary outcomes, aesthetic, radiographic and clinical parameters, as well as biological and mechanical complications, were considered. MATERIALS AND METHODS A systematic search was performed up to March 2022 to identify CCTs/RCTs comparing zirconia and titanium implants with a minimum of 12 months of follow-up. Meta-analysis was performed when ≥ 2 articles with similar characteristics were retrieved. RESULTS Four published articles with two RCTs (2 different patient populations) with 100 zirconia and 99 titanium implants that were followed up over 12-80 months were selected out of the 6040 articles. A non-statistically significant difference between zirconia and titanium implant survival at 12 months was suggested (P = 0.0938). The success rates were 57.5-93.3% and 57.1-100% for zirconia and titanium implants, respectively. The pink aesthetic score (PES) was higher for zirconia (10.33 ± 2.06 to 11.38 ± 0.92) compared to titanium implants (8.14 ± 3.58 to 11.56 ± 1.0). CONCLUSION Based on the 2 RCTs retrieved in the literature, similar survival rates were reported for zirconia and titanium implants in the short term (12 months of follow-up). Future RCTs are warranted to evaluate the long-term outcomes of zirconia implants. CLINICAL RELEVANCE Zirconia implants may be the procedure of choice, particularly in the aesthetic zone, since they show a similar survival and success rate as titanium implants on a short-term follow-up. TRIAL REGISTRATION Systematic review registration number-CRD42021288704 (PROSPERO).
Collapse
Affiliation(s)
- Ninad Milind Padhye
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
| | - Elena Calciolari
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
- Department of Medicine and Surgery, Centre of Dentistry, University of Parma, Parma, Italy
| | - Anina Nives Zuercher
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
- Clinic of Reconstructive Dentistry, Centre of Dental Medicine, Zurich, Switzerland
| | - Sara Tagliaferri
- Department of Medicine and Surgery, University of Parma, Parma, Italy
- Center of Excellence for Toxicological Research, CERT, University of Parma, Parma, Italy
| | - Nikos Donos
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK.
| |
Collapse
|
6
|
Roehling S, Gahlert M, Bacevic M, Woelfler H, Laleman I. Clinical and radiographic outcomes of zirconia dental implants-A systematic review and meta-analysis. Clin Oral Implants Res 2023; 34 Suppl 26:112-124. [PMID: 37750521 DOI: 10.1111/clr.14133] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 06/28/2023] [Accepted: 07/03/2023] [Indexed: 09/27/2023]
Abstract
OBJECTIVES For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other materials than titanium (alloy) on implant survival, marginal bone loss (MBL), and technical and biological complications after at least 5 years. MATERIALS AND METHODS An electronic (Medline, Embase, Web of Science) search was performed to identify observational clinical studies published from January 2000 investigating a minimum of 20 commercially available zirconia implants with a mean follow-up of at least 60 months. Primary outcome was implant survival, secondary outcomes included peri-implant MBL, probing depths (PDs), and technical and biological complications. Meta-analyses were performed to evaluate implant survival, MBL, and PD. RESULTS From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 4 prospective and 2 retrospective observational clinical cohort studies were included for data extraction. Meta-analyses estimated after 5 years of loading mean values of 97.2% (95% CI 94.7-99.1) for survival (277 implants, 221 patients), 1.1 mm (95% CI: 0.9-1.3) for MBL (229 implants, 173 patients), and 3.0 mm (95% CI 2.5-3.4) for PDs (231 implants, 175 patients). CONCLUSIONS After 5 years, commercially available zirconia implants showed reliable clinical performance based on survival rates, MBL, and PD values. However, more well-designed prospective clinical studies and randomized clinical trials investigating titanium and zirconia implants are needed to confirm the presently evaluated promising outcomes.
Collapse
Affiliation(s)
- S Roehling
- Clinic for Oral and Cranio-Maxillofacial Surgery, Hightech Research Center, University Hospital Basel, University of Basel, Basel, Switzerland
- Clinic for Oral and Cranio-Maxillofacial Surgery, Kantonsspital Aarau, Aarau, Switzerland
- Private Dental Clinic PD Dr. Gahlert & PD Dr. Roehling, Munich, Germany
| | - M Gahlert
- Clinic for Oral and Cranio-Maxillofacial Surgery, Hightech Research Center, University Hospital Basel, University of Basel, Basel, Switzerland
- Private Dental Clinic PD Dr. Gahlert & PD Dr. Roehling, Munich, Germany
- Sigmund Freud Private University, Vienna, Austria
| | - M Bacevic
- Department of Periodontology and Oral Surgery, Faculty of Medicine, University of Liège, Liège, Belgium
- Centre for Oral Clinical Research, Institute of Dentistry, London, UK
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
| | | | - I Laleman
- Department of Periodontology and Oral Surgery, Faculty of Medicine, University of Liège, Liège, Belgium
- Dental Biomaterials Research Unit (d-BRU), Faculty of Medicine, University of Liège, Liège, Belgium
| |
Collapse
|
7
|
Haimov E, Sarikov R, Haimov H, Juodzbalys G. Differences in Titanium, Titanium-Zirconium, Zirconia Implants Treatment Outcomes: a Systematic Literature Review and Meta-Analysis. J Oral Maxillofac Res 2023; 14:e1. [PMID: 37969951 PMCID: PMC10645476 DOI: 10.5037/jomr.2023.14301] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Accepted: 09/29/2023] [Indexed: 11/17/2023]
Abstract
Objectives The objective of this systematic review is to test the hypothesis that treatment with titanium, titanium-zirconium and zirconia dental implants has different clinical outcomes in survival rate, marginal bone loss, bleeding on probing, plaque control record, and probing depth. Material and Methods A systematic electronic search through the PubMed (MEDLINE) and Cochrane Library databases was performed to identify studies published between January 1, 2013 and January 1, 2023 containing a minimum of 10 patients per study comparing titanium (Ti), titanium-zirconium (Ti-Zr), and zirconia (Zr) dental implants. Ti, Ti-Zr, and Zr dental implant clinical outcomes were determined by evaluating survival rate, marginal bone level, bleeding on probing, probing depth, plaque control record. Quality and risk-of-bias assessment were evaluated by Cochrane risk of bias tool. Results A total of 1361 articles were screened, with 10 meeting the inclusion criteria and being utilized for this systematic review and meta-analysis. A total of 301 patients with 637 implants (304 Ti, 134 Ti-Zr, and 199 Zr) were evaluated, showing a survival rate of 97.7% for Ti, 98.6% for Ti-Zr, and 93.8% for Zr implants respectively. In a meta-analysis, no difference in marginal bone level was found between Ti, Ti-Zr, and Zr implants (P = 0.84). Conclusions Dental implant survival rate was lower in zirconia group. Assessment of marginal bone loss and bleeding on probing showed better results with titanium-zirconium dental implants. Plaque control result was similar in all groups. Due to limited sample size assessed it was not possible to obtain conclusion on probing depth parameter.
Collapse
Affiliation(s)
- Eliezer Haimov
- Faculty of Odontology, Medical Academy, Lithuanian University of Health Sciences, KaunasLithuania.
| | - Rafael Sarikov
- Oral and Maxillofacial Rehabilitation Department and the Temporomandibular Joint Diseases Unit, Rambam Medical Center, HaifaIsrael.
| | - Haim Haimov
- Faculty of Odontology, Medical Academy, Lithuanian University of Health Sciences, KaunasLithuania.
| | - Gintaras Juodzbalys
- Faculty of Odontology, Medical Academy, Lithuanian University of Health Sciences, KaunasLithuania.
| |
Collapse
|
8
|
Nueesch R, Karlin S, Fischer J, Rohr N. In Vitro Investigation of Material Combinations for Meso- and Suprastructures in a Biomimetic Approach to Restore One-Piece Zirconia Implants. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1355. [PMID: 36836985 PMCID: PMC9960926 DOI: 10.3390/ma16041355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/30/2023] [Accepted: 02/01/2023] [Indexed: 06/18/2023]
Abstract
The aim of this study was to find a suitable material combination to avoid cement excess in the marginal region of one-piece zirconia implant-supported restorations by means of a hybrid crown consisting of a meso- and a suprastructure. One-piece zirconia implants (n = 120) were embedded in epoxy resin. Microfilled resin composite mesostructures (n = 60), designed as caps, were bonded on the implant abutment with a primer only. A molar crown was constructed and cemented with a resin cement on top of the mesostructure as a suprastructure out of feldspar ceramic (n = 12), lithium-disilicate (n = 24), or zirconia (n = 24). Fracture load (n = 6) and retention force (n = 6) were measured immediately after storage in distilled water at 37 °C for 24 h, as well as after an additional exposure to artificial aging in a chewing simulator and simultaneous thermal cycling. For the measurement of the fracture load, monolithic crowns made of the employed restorative materials and identical in shape to the hybrid crowns served as controls (n = 6 each). Fracture load values for feldspar ceramic and lithium-disilicate hybrid crowns were slightly higher than those for the respective monolithic crowns at baseline and after aging, which was statistically significant only for feldspar crowns after aging. In contrast, fracture load values for zirconia monolithic crowns were higher than those for zirconia hybrid crowns, which was only statistically significant after aging. Artificial aging reduced the fracture load of feldspar and lithium-disilicate crowns both for hybrid and monolithic crowns. The effect was only statistically significant for lithium disilicate hybrid crowns. The fracture load for hybrid and monolithic zirconia crowns was increased by artificial aging without reaching statistical significance. The retention force of lithium-disilicate and zirconia hybrid crowns was not affected by artificial aging. Taking into account retention force and fracture load, lithium-disilicate hybrid crowns showed promising results.
Collapse
|
9
|
Sales PHDH, Barros AWP, Oliveira-Neto OBD, de Lima FJC, Carvalho ADAT, Leão JC. Do zirconia dental implants present better clinical results than titanium dental implants? A systematic review and meta-analysis. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2023; 124:101324. [PMID: 36330865 DOI: 10.1016/j.jormas.2022.10.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 10/26/2022] [Accepted: 10/28/2022] [Indexed: 11/05/2022]
Abstract
INTRODUCTION The purpose of this systematic review is to determine if the zirconia implants present better clinical results when compared to titanium implants. METHODS Searches were conducted in 5 databases including, until March 2022, by 2 independent reviewers, according to the inclusion and exclusion criteria established in the study and according whit this question: Do zirconia dental implants present better clinical results than titanium dental implants? RESULTS 3235 studies were initially found in the researched databases. 03 randomized clinical trials were included in this systematic review and meta-analysis. A total of 71 patients with 192 implants (87 titanium and 105 zirconia) were evaluated, showing an effectiveness of 87,4% and 78,1% respectively and there was no statistically significant difference in terms of survival rate in the meta-analysis (P = 0.70; I2 = 0%). Still in the meta-analysis, there was no statistically significant difference between titanium and zirconia implants in relation to the pink esthetich score or bleeding on probing, however, a favorable difference was observed for titanium in relation to marginal bone loss (P = 0.001; I2 = 0%). None of the studies evaluated had a low risk of bias. CONCLUSION Oral rehabilitation with zirconia implants showed no advantages over titanium in this systematic review. However, the small number of studies included and the uncertain risk of bias may raise doubts in this interpretation and the results should be analyzed with caution. New studies with greater methodological rigor, follow-up time and number of interventions should be performed in order to safely determine the indication for the use of zirconia implants.
Collapse
Affiliation(s)
- Pedro Henrique da Hora Sales
- Post-Graduated Program in Dentistry, Department of Prothesis and Oral and Maxillofacial Surgery, Federal University of Pernambuco (UFPE), Av. Prof. Moraes Rego 1235 - Cidade Universitária, Recife, PE 50670-901, Brazil.
| | - Ana Waleska Pessoa Barros
- Post-Graduated Program in Dentistry, Department of Prothesis and Oral and Maxillofacial Surgery, Federal University of Pernambuco (UFPE), Av. Prof. Moraes Rego 1235 - Cidade Universitária, Recife, PE 50670-901, Brazil
| | | | | | | | - Jair Carneiro Leão
- Department of Clinical and Preventive Dentistry, Federal University of Pernambuco (UFPE), Recife, PE, Brazil
| |
Collapse
|
10
|
Rohr N, Schönenberger AJ, Fischer J. Influence of Surface Treatment and Accelerated Ageing on Biaxial Flexural Strength and Hardness of Zirconia. MATERIALS (BASEL, SWITZERLAND) 2023; 16:910. [PMID: 36769917 PMCID: PMC9917567 DOI: 10.3390/ma16030910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/10/2023] [Accepted: 01/15/2023] [Indexed: 06/18/2023]
Abstract
The aim was to investigate how the surface treatment and the process of accelerated ageing of zirconia for dental implants affect the biaxial flexural strength and hardness. Zirconia discs with a diameter of 12.6 mm were subjected to either one of the following treatments: polishing (Zp); polishing and heat treatment at 1250 °C for 1 h (Zpt); machining (Zm); machining and heat treatment (Zmt); or sandblasting, acid-etching, and heat treatment (Z14) (n = 45 per group). Biaxial flexural strength and Martens hardness (HM) were measured without further treatment and after accelerated ageing for 5 h or 5 × 5 h according to ISO 13356 (n = 15 per group). Two-way ANOVA was applied to test the effect of surface treatment and ageing (α = 0.05). The reliability of the specimens was described with Weibull two-parameter distribution of biaxial flexural strength data. Overall, the surface treatment (p < 0.001) and ageing (p = 0.012) revealed a significant effect on biaxial flexural strength values, while HM was only affected by the surface treatment (p < 0.001) but not ageing (p = 0.160). Surface treatment significantly affected HM (p < 0.001) but not ageing (p = 0.160). The applied surface treatments affected the biaxial flexural strength and HM of zirconia. For accelerated ageing, a duration of both 5 h and 5 × 5 h is recommended to evaluate the effect of surface treatments. Zm was the most reliable surface as it was least affected by ageing and provided low standard deviations of biaxial flexural strength values.
Collapse
|
11
|
Duan C, Ye L, Zhang M, Yang L, Li C, Pan J, Wu Y, Cao Y. Clinical performance of zirconium implants compared to titanium implants: a systematic review and meta-analysis of randomized controlled trials. PeerJ 2023; 11:e15010. [PMID: 36949758 PMCID: PMC10026713 DOI: 10.7717/peerj.15010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 02/16/2023] [Indexed: 03/19/2023] Open
Abstract
Purpose To quantitatively assess and compare the clinical outcomes, including survival rate, success rate, and peri-implant indices of titanium and zirconium implants in randomized controlled trials. Methods The electronic databases searched included the Cochrane Central Register of Controlled Trials (CENTRAL), Medline via Ovid, EMBASE, and Web of Science. Randomized controlled trials (RCTs) that reported the effects of zirconium implants on primary outcomes, such as survival rate, success rate, marginal bone loss (MBL), and probing pocket depth (PPD), compared to titanium implants were included in this review. Two reviewers independently screened and selected the records, assessed their quality, and extracted the data from the included studies. Results A total of four studies from six publications reviewed were included. Two of the comparative studies were assessed at minimal risk of bias. Zirconium implants may have a lower survival rate (risk ratio (RR) = 0.91, CI [0.82-1.02], P = 0.100, I 2 = 0%) and a significantly lower success rate than titanium implants (RR = 0.87, CI [0.78-0.98], P = 0.030, I 2 = 0%). In addition, there was no difference between the titanium and zirconium implants in terms of MBL, PPD, bleeding on probing (BOP), plaque index (PI), and pink esthetic score (PES) (for MBL, MD = 0.25, CI [0.02-0.49], P = 0.033, I 2 = 0%; for PPD, MD = -0.07, CI [-0.19-0.05], P = 0.250, I 2 = 31%). Conclusion Zirconium implants may have higher failure rates due to their mechanical weakness. Zirconium implants should be strictly assessed before they enter the market. Further studies are required to confirm these findings.
Collapse
Affiliation(s)
- Chengchen Duan
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China College of Stomatology, Sichuan University, Chengdu, China
| | - Li Ye
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Mengyun Zhang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China College of Stomatology, Sichuan University, Chengdu, China
| | - Lei Yang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China College of Stomatology, Sichuan University, Chengdu, China
| | - Chunjie Li
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Head and Neck Oncology, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Jian Pan
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yingying Wu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Oral implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yubin Cao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| |
Collapse
|
12
|
Hassouna M, Al-Zordk W, Aboshilib M, Ghazy M. Clinical and radiographic prospective study of customized one-piece titanium and one-piece fusion-sputtered zirconia implants: five-year mean follow-up. BMC Oral Health 2022; 22:531. [PMID: 36424624 PMCID: PMC9685929 DOI: 10.1186/s12903-022-02600-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 09/26/2022] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND To evaluate the clinical and radiographic assessment of customized fusion-sputtered one-piece zirconia implants. METHODS Twenty-eight patients received either fusion sputtered one-piece zirconia implants (n = 14) or one-piece titanium implants (n = 14). All implants were one-piece designs. After 4 months of immediate loading, all implants were restored with a monolithic zirconia crown. All implants were evaluated at baseline, 6 months, 1 year, 2 years, and 5 years. Implant mobility, plaque index, and gingival index evaluations were performed. The measurements of marginal bone level were calculated radiographically. RESULTS All implants were well maintained through the evaluation period with a 100% survival rate without any clinical complications. Regarding gingival index, there was no statistically significant difference (P = .364) between zirconia (3.3 ± 0.7 mm) and titanium (3.5 ± 0.6 mm) implants, after 5 years. There was no statistically significant difference (P = .470) between zirconia (1.77 ± 0.039 mm) and titanium (1.80 ± 0.28 mm) implants regarding marginal bone loss, after 5 years. CONCLUSIONS One-piece fusion-sputtered zirconia implant represents a reliable treatment modality in replacing a missing tooth in the esthetic zone.
Collapse
Affiliation(s)
- Mahy Hassouna
- grid.10251.370000000103426662Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Walid Al-Zordk
- grid.10251.370000000103426662Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Moustafa Aboshilib
- grid.7155.60000 0001 2260 6941Biomaterials Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Mohamed Ghazy
- grid.10251.370000000103426662Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt ,Faculty of Dentistry, Horus University, New Damietta, Egypt
| |
Collapse
|
13
|
Müller-Heupt LK, Schiegnitz E, Kaya S, Jacobi-Gresser E, Kämmerer PW, Al-Nawas B. The German S3 guideline on titanium hypersensitivity in implant dentistry: consensus statements and recommendations. Int J Implant Dent 2022; 8:51. [PMID: 36329297 PMCID: PMC9633908 DOI: 10.1186/s40729-022-00451-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 10/13/2022] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND There is currently a lack of guidelines for clinicians regarding titanium hypersensitivity in implant dentistry. Diagnostic tests such as the epicutaneous test or the lymphocyte transformation test showed inconsistent results regarding reliability and validity and thus, evidence-based consensus recommendations regarding diagnostic and therapeutic options may be helpful in clinical decision-making. Therefore, the German S3 guideline on titanium hypersensitivity in implant dentistry was developed. FINDINGS In the objectives, procedure, voting method and venue were defined and the consensus participants were invited. A systematic literature research was performed, and the overall quality of the evidence was rated according to the GRADE working group. Eight recommendations were formulated within the framework of a structured consensus conference under independent moderation and could be voted on with strong consensus (> 95% agreement). The formulated statements and recommendations were developed in small groups according to the guidelines of the Association of the Scientific Medical Societies in Germany (AWMF) and were discussed and agreed upon in the plenum. CONCLUSIONS For reasonable decision-making, a patient's clinical symptoms should be regarded as leading parameters, which are usually expressed by a local inflammatory reaction with subsequent disturbed osseous integration. Allergy tests, such as the epicutaneous test or the lymphocyte transformation test are not helpful in titanium intolerance assessments, since these tests indicate T cell-mediated allergies, which are not observed in titanium intolerance reactions. Other metals and impurities that might be present in superstructures or alloys also need to be considered as the cause of an intolerance reaction and a trigger for contact sensitization. In the case of a suspected titanium particle-related, local immunologically induced inflammatory reaction with subsequent impaired osseous integration, dental ceramic implants can be considered as a therapeutic option.
Collapse
Affiliation(s)
- Lena Katharina Müller-Heupt
- Department of Oral- and Maxillofacial Surgery, Plastic Surgery, University Medical Centre of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131, Mainz, Germany.
| | - Eik Schiegnitz
- grid.410607.4Department of Oral- and Maxillofacial Surgery, Plastic Surgery, University Medical Centre of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131 Mainz, Germany
| | - Sebahat Kaya
- grid.410607.4Department of Oral- and Maxillofacial Surgery, Plastic Surgery, University Medical Centre of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131 Mainz, Germany
| | | | - Peer Wolfgang Kämmerer
- grid.410607.4Department of Oral- and Maxillofacial Surgery, Plastic Surgery, University Medical Centre of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131 Mainz, Germany
| | - Bilal Al-Nawas
- grid.410607.4Department of Oral- and Maxillofacial Surgery, Plastic Surgery, University Medical Centre of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131 Mainz, Germany
| |
Collapse
|
14
|
Zirconia versus Titanium Implants: 8-Year Follow-Up in a Patient Cohort Contrasted with Histological Evidence from a Preclinical Animal Model. MATERIALS 2022; 15:ma15155322. [PMID: 35955254 PMCID: PMC9369473 DOI: 10.3390/ma15155322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 07/18/2022] [Accepted: 07/29/2022] [Indexed: 02/04/2023]
Abstract
Zirconia ceramic (ZC) implants are becoming more common, but comparisons between preclinical histology and long-term clinical trials are rare. This investigation comprised (1) 8-year clinical follow-up of one-piece ZC or titanium (Ti) implants supporting full overdentures and (2) histomorphometric analysis of the same implants in an animal model, comparing implants with various surface treatments. Methods: (1) Clinical trial: 24 completely edentulous participants (2 groups of N = 12) received 7 implants (one-piece ball-abutment ZC or Ti; maxilla N = 4, mandible N = 3) restored with implant overdentures. Outcomes after 8-years included survival, peri-implant bone levels, soft-tissue responses, and prosthodontic issues. (2) Preclinical trial: 10 New Zealand sheep received 4 implants bilaterally in the femoral condyle: Southern Implants ZC or Ti one-piece implants, identical to the clinical trial, and controls: Southern ITC® two-piece implants with the same surface or Nobel (NBC) anodised (TiUnite™) surface. %Bone-implant contact (%BIC) was measured after 12 weeks of unloaded healing. Results: 8 of 24 participants (33%) of an average age of 75 ± 8 years were recalled; 21% of original participants had died, and 46% could not be contacted. 80.4% of implants survived; excluding palatal sites, 87.5% of Ti and 79% of ZC implants survived. All failed implants were in the maxilla. Three ZC implants had fractured. Bone loss was similar for Ti vs. ZC; pocket depths (p = 0.04) and attachment levels (p = 0.02) were greater for Ti than ZC implants. (1.7 ± 1.6 mm vs. 1.6 ± 1.3 mm). All implants in sheep femurs survived. %BIC was not statistically different for one-piece blasted surface Ti (80 ± 19%) versus ZC (76 ± 20%) or ITC® (75 ± 16 mm); NBC had significantly higher %BIC than ITC (84 ± 17%, p = 0.4). Conclusion: Short-term preclinical results for ZC and Ti one-piece implants showed excellent bone-implant contact in unloaded femoral sites. This differed from the long-term clinical results in older-aged, edentulous participants. While ZC and Ti implants showed equivalent performance, the risks of peri-implantitis and implant loss in older, completely edentulous patients remain a significant factor.
Collapse
|
15
|
Relevant Aspects of Titanium and Zirconia Dental Implants for Their Fatigue and Osseointegration Behaviors. MATERIALS 2022; 15:ma15114036. [PMID: 35683331 PMCID: PMC9182570 DOI: 10.3390/ma15114036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 05/31/2022] [Accepted: 06/04/2022] [Indexed: 01/27/2023]
Abstract
Osseointegration capacity and good mechanical behavior are key to the success of the dental implant. In many investigations, comparisons of properties are made using different dental implant designs and therefore the results can be influenced by the macrodesign of the dental implant. In this work, studies were carried out with the same dental implant model using different roughness and different materials—commercially pure titanium (grade 4) and zirconia. For this purpose, 80 smooth passivated titanium (Ti), 80 smooth zirconia (ZrO2), and 80 rough passivated titanium (Ti-R) dental implants were used. The samples were characterized by their roughness, wettability, surface energy, residual stresses, and fatigue behavior. The implants were implanted in minipigs for 4 and 12 weeks. The animals were sacrificed, and histological studies were carried out to determine the osseointegration parameters for each of the implantation times. Ti and ZrO2 dental implants have very similar wettability and surface energy properties. However, the roughness causes a decrease in the hydrophilic character and a decrease of the total surface energy and especially the dispersive component, while the polar component is higher. Due to the compressive residual stresses of alumina sandblasting, the rough dental implant has the best fatigue behavior, followed by Ti and due to the lack of toughness and rapid crack propagation the ZrO2 implants have the worst fatigue behavior. The bone index contact (BIC) values for 4 weeks were around 25% for Ti, 32% for ZrO2, and 45% for Ti-R. After 12 weeks the Ti dental implants increased to 42%, for Ti, 43% for ZrO2, and an important increase to 76% was observed for Ti-R implants. In vivo results showed that the key factor that improves osseointegration is roughness. There was no significant difference between ZrO2 and Ti implants without sandblasting.
Collapse
|
16
|
Clinical Performance Comparing Titanium and Titanium–Zirconium or Zirconia Dental Implants: A Systematic Review of Randomized Controlled Trials. Dent J (Basel) 2022; 10:dj10050083. [PMID: 35621536 PMCID: PMC9140125 DOI: 10.3390/dj10050083] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 05/02/2022] [Accepted: 05/09/2022] [Indexed: 01/27/2023] Open
Abstract
Objectives: This study aimed to compare clinical results between titanium (Ti), zirconia (Zr), or titanium–zirconium (TZ) dental implants and to analyze survival rate (SR), bleeding on probing (BoP), marginal bone loss (MBL), and/or probing depth (PD). Data source: Manual and electronic searches were conducted (PubMed and Web of Science) to identify randomized controlled trials that compared the outcomes of at least two implant types (control and test group) within the same study. The focused question was determined according to the PICOT strategy. Seven studies were included out of 202 research studies initially found. The follow-up periods ranged from 12 to 80 months, and the mean age was from 43.3 to 65.8 years old. The SR for Ti, TZ, and Zr implants ranged from 92.6% to 100%, 95.8% to 100%, and 87.5% to 91.25%, respectively; MBL for Ti, TZ, and Zr implants varied from −1.17 mm to −0.125 mm for Ti, −0.6 mm to −0.32 mm for TZ, and −0.25 mm to −1.38 mm for Zr. Studies showed a low incidence of mucositis and peri-implantitis; however, BoP for Zr was 16.43%, Ti ranged between 10% and 20%, and TZ from 10% to 13.8%. PD for Ti ranged from 1.6 mm to 3.05 mm, TZ was 3.12 mm (only one study), and Zr ranged from 2.21 mm to 2.6 mm. Conclusion: All three types of implants showed similar tissue behavior. However, the TZ group had better results when compared with Ti and Zr for SR, MBL, and BoP, except for PD. Furthermore, the worst SR was found in the Zr implants group.
Collapse
|
17
|
Fiorillo L, Cicciù M, Tozum TF, Saccucci M, Orlando C, Romano GL, D’Amico C, Cervino G. Endosseous Dental Implant Materials and Clinical Outcomes of Different Alloys: A Systematic Review. MATERIALS (BASEL, SWITZERLAND) 2022; 15:1979. [PMID: 35269211 PMCID: PMC8911578 DOI: 10.3390/ma15051979] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/01/2022] [Accepted: 03/04/2022] [Indexed: 12/17/2022]
Abstract
In recent years, implantology has made significant progress, as it has now become a safe and predictable practice. The development of new geometries, primary and secondary, of new surfaces and alloys, has made this possible. The purpose of this review is to analyze the different alloys present on the market, such as that in zirconia, and evaluate their clinical differences with those most commonly used, such as those in grade IV titanium. The review, conducted on major scientific databases such as Scopus, PubMed, Web of Science and MDPI yielded a startling number of 305 results. After the application of the filters and the evaluation of the results in the review, only 10 Randomized Clinical Trials (RCTs) were included. Multiple outcomes were considered, such as Marginal Bone Level (MBL), Bleeding on Probing (BoP), Survival Rate, Success Rate and parameters related to aesthetic and prosthetic factors. There are currently no statistically significant differences between the use of zirconia implants and titanium implants, neither for fixed prosthetic restorations nor for overdenture restorations. Only the cases reported complain about the rigidity and, therefore, the possibility of fracture of the zirconium. Certainly the continuous improvement in these materials will ensure that they could be used safely while maintaining their high aesthetic performance.
Collapse
Affiliation(s)
- Luca Fiorillo
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, Messina University, 98100 Messina, Italy; (L.F.); (C.D.); (G.C.)
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, Second University of Naples, 80100 Naples, Italy
- Department of Dentistry, University of Aldent, 1000 Tirana, Albania
| | - Marco Cicciù
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, Messina University, 98100 Messina, Italy; (L.F.); (C.D.); (G.C.)
| | - Tolga Fikret Tozum
- Department of Periodontics, College of Dentistry, University of Illinois at Chicago, Chicago, IL 6007, USA;
| | - Matteo Saccucci
- Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy;
| | - Cristiano Orlando
- Behavioural Health Institute, Loma Linda University, Loma Linda, CA 92354, USA;
| | - Giovanni Luca Romano
- Department of Biomedical and Biotechnological Sciences (BIOMETEC), Section of Pharmacology, University of Catania, 95124 Catania, Italy;
| | - Cesare D’Amico
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, Messina University, 98100 Messina, Italy; (L.F.); (C.D.); (G.C.)
| | - Gabriele Cervino
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, Messina University, 98100 Messina, Italy; (L.F.); (C.D.); (G.C.)
| |
Collapse
|
18
|
Arlucea N, Brizuela-Velasco A, Dieguez-Pereira M, Punset M, Molmeneu M, Sánchez Lasheras F, deLlanos-Lanchares H, Álvarez-Arenal Á. Zirconia vs. Titanium Dental Implants: Primary Stability In-Vitro Analysis. MATERIALS 2021; 14:ma14247886. [PMID: 34947480 PMCID: PMC8705369 DOI: 10.3390/ma14247886] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Revised: 12/17/2021] [Accepted: 12/18/2021] [Indexed: 11/16/2022]
Abstract
The present experimental trial uses two types of dental implants, one made of titanium (Ti6Al4V) and the other one of zirconia (ZrO2), but both of identical design, to compare their stability and micro-movements values under load. One of each type of implant (n = 42) was placed into 21 cow ribs, recording the insertion torque and the resonance frequency using a specific transducer. Subsequently, a prosthetic crown made of PMMA was screwed onto each of the implants in the sample. They were then subjected to a static compression load on the vestibular cusp of the crown. The resulting micromovements were measured. The zirconia implants obtained a higher mean of both IT and RFA when compared with those of titanium, with statistically significant differences in both cases (p = 0.0483 and p = 0.0296). However, the micromovement values when load was applied were very similar for both types, with the differences between them (p = 0.3867) not found to be statistically significant. The results show that zirconia implants have higher implant stability values than titanium implants. However, the fact that there are no differences in micromobility values implies that caution should be exercised when applying clinical protocols for zirconia based on RFA, which only has evidence for titanium.
Collapse
Affiliation(s)
- Nerea Arlucea
- Department of Prosthodontics and Occlusion, School of Dentistry, University of Oviedo, c/Catedrático Serrano s/n, 33006 Oviedo, Spain; (N.A.); (A.B.-V.); (M.D.-P.); (H.d.-L.); (Á.Á.-A.)
| | - Aritza Brizuela-Velasco
- Department of Prosthodontics and Occlusion, School of Dentistry, University of Oviedo, c/Catedrático Serrano s/n, 33006 Oviedo, Spain; (N.A.); (A.B.-V.); (M.D.-P.); (H.d.-L.); (Á.Á.-A.)
| | - Markel Dieguez-Pereira
- Department of Prosthodontics and Occlusion, School of Dentistry, University of Oviedo, c/Catedrático Serrano s/n, 33006 Oviedo, Spain; (N.A.); (A.B.-V.); (M.D.-P.); (H.d.-L.); (Á.Á.-A.)
| | - Miquel Punset
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Metallurgy, EEBE, Technical University of Catalonia (UPC), 08034 Barcelona, Spain; (M.P.); (M.M.)
- UPC Innovation and Technology Center (CIT-UPC), Technical University of Catalonia (UPC), C. Jordi Girona 3-1, 08034 Barcelona, Spain
- Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10-14, 08019 Barcelona, Spain
| | - Meritxell Molmeneu
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Metallurgy, EEBE, Technical University of Catalonia (UPC), 08034 Barcelona, Spain; (M.P.); (M.M.)
- Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10-14, 08019 Barcelona, Spain
| | - Fernando Sánchez Lasheras
- Department of Mathematics c/Federico García Lorca 18, University of Oviedo, 33007 Oviedo, Spain
- Instituto Universitario de Ciencias y Tecnologías Espaciales de Asturias (ICTEA), c/Independencia 13, 33004 Oviedo, Spain
- Correspondence:
| | - Hector deLlanos-Lanchares
- Department of Prosthodontics and Occlusion, School of Dentistry, University of Oviedo, c/Catedrático Serrano s/n, 33006 Oviedo, Spain; (N.A.); (A.B.-V.); (M.D.-P.); (H.d.-L.); (Á.Á.-A.)
| | - Ángel Álvarez-Arenal
- Department of Prosthodontics and Occlusion, School of Dentistry, University of Oviedo, c/Catedrático Serrano s/n, 33006 Oviedo, Spain; (N.A.); (A.B.-V.); (M.D.-P.); (H.d.-L.); (Á.Á.-A.)
| |
Collapse
|
19
|
Gil J, Delgado-García-Menocal JA, Velasco-Ortega E, Bosch B, Delgado L, Pérez-Antoñanzas R, Fernández-Fairén M. Comparison of zirconia degradation in dental implants and femoral balls: an X-ray diffraction and nanoindentation study. Int J Implant Dent 2021; 7:103. [PMID: 34657990 PMCID: PMC8520857 DOI: 10.1186/s40729-021-00383-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Accepted: 09/16/2021] [Indexed: 11/19/2022] Open
Abstract
Background New tetragonal zirconia polycrystal dental implants stabilized with yttria (Y-TZP) have appeared in the implantology market in the form of single piece or two-piece zircona implant system. These new type of implants improve the aesthetical properties compared to conventional commercially pure (c.p.) titanium used for implants, although the long term mechanical behavior of these new implants is not yet well known. In orthopaedics, the application of zirconia as femoral balls presented an important controversial use due to the premature fracture once implanted. Y-TZP dental implants can be affected by hydrothermal degradation and its behavior should be analysed to avoid a premature fracture. The scientific question behind the study is to analyse if the degradation mechanism observed in orthopaedics applications of Y-TZP is similar to that of Y-TZP for dental applications. Materials and methods For this purpose, 30 original Y-TZP dental implants and 42 Y-TZP femoral balls fractured in vivo have been studied. Dental implants were submitted to an accelerated hydrothermal degradation to compare with the femoral balls fractured in vivo. Phase transformation as well as the mechanical behaviour of the degraded samples was studied by X ray diffraction and nanoindentation tests, respectively. Results Results have shown that the fracture mechanism of dental implants does not resemble the mechanism observed in orthopaedic samples, presenting a good long-term behaviour. Conclusion The results ensure the good performance of zirconia dental implants, because the degradation of the ceramic is very limited and does not affect the mechanical properties.
Collapse
Affiliation(s)
- Javier Gil
- Bioengineering Institute of Technology, Universitat Internacional de Catalunya, c/Josep Trueta s/n. 08195-Sant Cugat del Vallés, Barcelona, Spain. .,School of Dentistry, Universitat Internacional de Catalunya, c/Josep Trueta s/n. 08195-Sant Cugat del Vallés, Barcelona, Spain.
| | - José Angel Delgado-García-Menocal
- Bioengineering Institute of Technology, Universitat Internacional de Catalunya, c/Josep Trueta s/n. 08195-Sant Cugat del Vallés, Barcelona, Spain.,School of Dentistry, Universitat Internacional de Catalunya, c/Josep Trueta s/n. 08195-Sant Cugat del Vallés, Barcelona, Spain
| | | | - Begoña Bosch
- Bioengineering Institute of Technology, Universitat Internacional de Catalunya, c/Josep Trueta s/n. 08195-Sant Cugat del Vallés, Barcelona, Spain
| | - Luis Delgado
- Bioengineering Institute of Technology, Universitat Internacional de Catalunya, c/Josep Trueta s/n. 08195-Sant Cugat del Vallés, Barcelona, Spain
| | - Román Pérez-Antoñanzas
- Bioengineering Institute of Technology, Universitat Internacional de Catalunya, c/Josep Trueta s/n. 08195-Sant Cugat del Vallés, Barcelona, Spain
| | - Mariano Fernández-Fairén
- Bioengineering Institute of Technology, Universitat Internacional de Catalunya, c/Josep Trueta s/n. 08195-Sant Cugat del Vallés, Barcelona, Spain
| |
Collapse
|
20
|
Hodásová Ľ, Alemán C, del Valle LJ, Llanes L, Fargas G, Armelin E. 3D-Printed Polymer-Infiltrated Ceramic Network with Biocompatible Adhesive to Potentiate Dental Implant Applications. MATERIALS (BASEL, SWITZERLAND) 2021; 14:5513. [PMID: 34639905 PMCID: PMC8509517 DOI: 10.3390/ma14195513] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 09/14/2021] [Accepted: 09/18/2021] [Indexed: 11/16/2022]
Abstract
The aim of this work was to prepare and characterize polymer-ceramic composite material for dental applications, which must resist fracture and wear under extreme forces. It must also be compatible with the hostile environment of the oral cavity. The most common restorative and biocompatible copolymer, 2,2-bis(p-(2'-2-hydroxy-3'-methacryloxypropoxy)phenyl)propane and triethyleneglycol dimethacrylate, was combined with 3D-printed yttria-stabilized tetragonal zirconia scaffolds with a 50% infill. The proper scaffold deposition and morphology of samples with 50% zirconia infill were studied by means of X-ray computed microtomography and scanning electron microscopy. Samples that were infiltrated with copolymer were observed under compression stress, and the structure's failure was recorded using an Infrared Vic 2DTM camera, in comparison with empty scaffolds. The biocompatibility of the composite material was ascertained with an MG-63 cell viability assay. The microtomography proves the homogeneous distribution of pores throughout the whole sample, whereas the presence of the biocompatible copolymer among the ceramic filaments, referred to as a polymer-infiltrated ceramic network (PICN), results in a safety "damper", preventing crack propagation and securing the desired material flexibility, as observed by an infrared camera in real time. The study represents a challenge for future dental implant applications, demonstrating that it is possible to combine the fast robocasting of ceramic paste and covalent bonding of polymer adhesive for hybrid material stabilization.
Collapse
Affiliation(s)
- Ľudmila Hodásová
- Departament d’Enginyeria Química, IMEM Group, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, 2nd Floor, 08019 Barcelona, Spain; (Ľ.H.); (C.A.); (L.J.d.V.)
- Departament de Ciència i Enginyeria de Materials, CIEFMA Group, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, 1st Floor, 08019 Barcelona, Spain;
- Barcelona Research Center for Multiscale Science and Engineering, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, Basement Floor, 08019 Barcelona, Spain
| | - Carlos Alemán
- Departament d’Enginyeria Química, IMEM Group, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, 2nd Floor, 08019 Barcelona, Spain; (Ľ.H.); (C.A.); (L.J.d.V.)
- Barcelona Research Center for Multiscale Science and Engineering, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, Basement Floor, 08019 Barcelona, Spain
| | - Luís J. del Valle
- Departament d’Enginyeria Química, IMEM Group, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, 2nd Floor, 08019 Barcelona, Spain; (Ľ.H.); (C.A.); (L.J.d.V.)
- Barcelona Research Center for Multiscale Science and Engineering, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, Basement Floor, 08019 Barcelona, Spain
| | - Luis Llanes
- Departament de Ciència i Enginyeria de Materials, CIEFMA Group, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, 1st Floor, 08019 Barcelona, Spain;
- Barcelona Research Center for Multiscale Science and Engineering, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, Basement Floor, 08019 Barcelona, Spain
| | - Gemma Fargas
- Departament de Ciència i Enginyeria de Materials, CIEFMA Group, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, 1st Floor, 08019 Barcelona, Spain;
- Barcelona Research Center for Multiscale Science and Engineering, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, Basement Floor, 08019 Barcelona, Spain
| | - Elaine Armelin
- Departament d’Enginyeria Química, IMEM Group, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, 2nd Floor, 08019 Barcelona, Spain; (Ľ.H.); (C.A.); (L.J.d.V.)
- Barcelona Research Center for Multiscale Science and Engineering, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Building I, Basement Floor, 08019 Barcelona, Spain
| |
Collapse
|
21
|
Poli PP, de Miranda FV, Polo TOB, Santiago Júnior JF, Lima Neto TJ, Rios BR, Assunção WG, Ervolino E, Maiorana C, Faverani LP. Titanium Allergy Caused by Dental Implants: A Systematic Literature Review and Case Report. MATERIALS 2021; 14:ma14185239. [PMID: 34576463 PMCID: PMC8465040 DOI: 10.3390/ma14185239] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 08/25/2021] [Accepted: 09/08/2021] [Indexed: 12/29/2022]
Abstract
(1) Background: Hypersensitivity reactions to metals may arise in predisposed patients chronically exposed to metallic materials, including dental implants made of titanium alloys. The purpose of this article was to systematically review titanium allergy manifestations in patients treated with dental implants and report a clinical case; (2) Methods: A systematic electronic search was performed for articles published in the English language until July 2021. The following eligibility criteria were adopted: (1) Population: individuals undergoing titanium and/or titanium alloy implant-supported rehabilitations; (2) Exposure: peri-implant soft tissue reactions attributable to implant insertion; (3) Outcome: evidence of titanium allergy, diagnostic methods, and forms of resolution; (3) Results: The included studies, in summary, presented evidence that titanium should not be considered an inert material, being able to trigger allergic reactions, and may be responsible for implant failure. A 55-year-old male patient received 3 implants in the posterior region of the left mandible and presented an epulis-like lesion developed from the peri-implant mucosa. The immunohistochemical analysis of the biopsy specimen confirmed the initial diagnosis of allergic reaction to titanium; (4) Conclusions: Although the evidence is weak, and titanium allergy has a low incidence, hypersensitivity reactions should not be underestimated. A rapid and conclusive diagnosis is mandatory to prevent further complications.
Collapse
Affiliation(s)
- Pier Paolo Poli
- Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Odontostomatology Unit, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, University of Milan, 20122 Milan, Italy
| | - Fábio Vieira de Miranda
- Department of Diagnosis and Surgery, Division of Oral and Maxillofacial Surgery and Implantology, School of Dentistry, São Paulo State University-UNESP, Araçatuba 16015-050, SP, Brazil
| | - Tárik Ocon Braga Polo
- Department of Diagnosis and Surgery, Division of Oral and Maxillofacial Surgery and Implantology, School of Dentistry, São Paulo State University-UNESP, Araçatuba 16015-050, SP, Brazil
| | | | - Tiburtino José Lima Neto
- Department of Diagnosis and Surgery, Division of Oral and Maxillofacial Surgery and Implantology, School of Dentistry, São Paulo State University-UNESP, Araçatuba 16015-050, SP, Brazil
| | - Bárbara Ribeiro Rios
- Department of Diagnosis and Surgery, Division of Oral and Maxillofacial Surgery and Implantology, School of Dentistry, São Paulo State University-UNESP, Araçatuba 16015-050, SP, Brazil
| | - Wirley Gonçalves Assunção
- Department of Dental Materials and Prosthodontics, School of Dentistry, São Paulo State University-UNESP, Araçatuba 16015-050, SP, Brazil
| | - Edilson Ervolino
- Department of Basic Sciences, School of Dentistry, São Paulo State University-UNESP, Araçatuba 16015-050, SP, Brazil
| | - Carlo Maiorana
- Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Odontostomatology Unit, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, University of Milan, 20122 Milan, Italy
| | - Leonardo Perez Faverani
- Department of Diagnosis and Surgery, Division of Oral and Maxillofacial Surgery and Implantology, School of Dentistry, São Paulo State University-UNESP, Araçatuba 16015-050, SP, Brazil
| |
Collapse
|
22
|
Biological activity of titania coating prepared with zirconium oxychloride and titania on zirconia surface. J Mech Behav Biomed Mater 2021; 123:104780. [PMID: 34416536 DOI: 10.1016/j.jmbbm.2021.104780] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 08/09/2021] [Accepted: 08/10/2021] [Indexed: 11/20/2022]
Abstract
Zirconia is recognized as a promising dental implant material because of its good biocompatibility, sufficient mechanical strength, minimal ion release and aesthetic effects similar to natural teeth. However, the limitations of inert surface of zirconia affect the long-term efficacy of zirconia implants. To enhance the osseointegration of zirconia implants, titania (TiO2) coating is prepared on the zirconia surface by immersion in a mixed zirconium oxychloride (ZrOCl2) and TiO2 suspension in a water bath. The surface and longitudinal section morphology are observed by scanning electron microscopy (SEM). The chemical composition is evaluated through energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). The roughness and hydrophilicity of zirconia surface are also examined. A three-point bending test is conducted on the samples to explore the effect of this surface treatment on the mechanical strength of zirconia. Vickers hardness measurements are performed to evaluate the gradient change of the longitudinal section of the zirconia substrate. The MC3T3-E1 cells are seeded on zirconia discs, and a LIVE/DEAD double-staining test is conducted to detect the cytotoxicity of the TiO2 coating. The cell morphology is studied through fluorescence microscope. The degrees of cell proliferation, mineralization and alkaline phosphatase (ALP) activity are calculated and compared. Detection of the mRNA expression of osteogenic differentiation-related markers is performed by RT-PCR. A TiO2 coating is generated on the zirconia surface and significantly improves the surface roughness and hydrophilicity while not adversely affecting the mechanical strength of zirconia. The hardness of the zirconia substrate shows a gradient change. The TiO2 coating can promote proliferation, spreading and osteogenic differentiation of MC3T3-E1 cells. These findings suggest that modifying the surface of zirconia with a TiO2 coating may have a favourable osteogenic effect.
Collapse
|
23
|
One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study. MATERIALS 2021; 14:ma14154179. [PMID: 34361372 PMCID: PMC8348384 DOI: 10.3390/ma14154179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 07/19/2021] [Accepted: 07/20/2021] [Indexed: 11/26/2022]
Abstract
Objective: To evaluate the peri-implant hard tissue change at 6 and 12 months after implant placement between definitive abutment placed at the same time of implant surgery, never removing it, and healing abutment disconnected and reconnected three times until the placement of the final rehabilitation. Material and methods: Each partial edentulous patient could receive between 1 and 4 platform-switched implants in the posterior regions. If the implants had primary stability—implant stability quotient (ISQ) equal to or greater than 50, they were randomized to the test group with the abutment inserted at the same time of implant placement (DA) or to the control group, receiving a healing abutment (PA). At 6 and 12 months after surgery, data related with vertical bone level changes (primary outcome) and other clinical parameters (implant mobility, bleeding on probing, probing depth, plaque index) were assessed. Results: 53 implants were included in the trial and completed 12 months follow-up (overall survival rate: 100%). All implants achieved primary stability, with an average ISQ value of 80.9 on the day of surgery. From surgery to 6 months, the mean bone loss was 0.14 ± 0.18 mm for the DA group and 0.23 ± 0.29 mm for the PA group, without statistical significance difference. Between 6 and 12 months, the mean bone loss was 0.14 ± 0.21 mm for the DA group and 0.21 ± 0.27 mm for the PA group, also without statistical significance between the two groups. There were no statistically significant differences (p = 0.330) in total bone loss after 12 months between the control and the study groups. Conclusions: The one abutment one time protocol has at least an equivalent effect on the peri-implant bone level changes when compared with the use of healing abutments that are disconnected and reconnected at least three times.
Collapse
|
24
|
Ruiz Henao PA, Caneiro Queija L, Mareque S, Tasende Pereira A, Liñares González A, Blanco Carrión J. Titanium vs ceramic single dental implants in the anterior maxilla: A 12-month randomized clinical trial. Clin Oral Implants Res 2021; 32:951-961. [PMID: 34061402 DOI: 10.1111/clr.13788] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 04/13/2021] [Accepted: 05/13/2021] [Indexed: 01/10/2023]
Abstract
OBJECTIVE The aim of this randomized clinical trial was to compare ceramic and titanium implants with respect to the esthetic and clinical parameters, and patient-reported outcome measures (PROMs). MATERIAL AND METHODS Thirty patients received thirty implants (8-12 mm in length, 3.3 mm diameter, and a tissue level design) to replace single teeth in the anterior maxilla. Patients were randomly allocated to receive a ceramic or a titanium implant. Esthetic, clinical parameters, and PROMs were evaluated 18 months after surgery. RESULTS At 12 months post-final loading, there were no significant differences between groups with respect to esthetics. Mean Index Crown Aesthetic score was 6.31 (95% C.I. 4.59-8.04) and 6.07 (95% C.I. 4.21-7.93) for ceramic and titanium implants, respectively. The pink esthetic score (PES) was 7.81 (95% C.I. 6.90-8.73) for ceramic implants and 7.86 (95% C.I. 7.11-8.60) for titanium implants, with no significant differences between groups. No statistically significant differences were found for any of the other clinical parameters and PROMs. CONCLUSIONS Monotype ceramic implants have proven to be a good treatment option in the upper anterior sector, showing favorable esthetic results, being comparable to titanium implants. This clinical trial has been registered in clinical trials with the identifier CI_RCT_US16 and registration number NCT04707677. A retrospective registration of the clinical trial was carried out since registration was not mandatory on the date the study began.
Collapse
Affiliation(s)
- Paula Andrea Ruiz Henao
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Leticia Caneiro Queija
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Santiago Mareque
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Almudena Tasende Pereira
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Antonio Liñares González
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain.,Odontología Médico-Quirúrgica (OMEQUI) Research Group, Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Juan Blanco Carrión
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain.,Odontología Médico-Quirúrgica (OMEQUI) Research Group, Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| |
Collapse
|
25
|
Chacun D, Lafon A, Courtois N, Reveron H, Chevalier J, Margossian P, Alves A, Gritsch K, Grosgogeat B. Histologic and histomorphometric evaluation of new zirconia-based ceramic dental implants: A preclinical study in dogs. Dent Mater 2021; 37:1377-1389. [PMID: 34238605 DOI: 10.1016/j.dental.2021.06.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 06/12/2021] [Accepted: 06/17/2021] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Healing of soft tissues and improvement of aesthetics have become major research objectives in implantology and renewed the interest for ceramics implants. The aim of this study was to evaluate the pre-clinical performance of screw-shaped sandblasted-etched implants processed from an innovative zirconia-based ceramic composite, in comparison to titanium. METHODS Twenty-four ceramic and twenty-four titanium screw-shaped sandblasted-etched dental implants were tested in a split-mouth design in six Beagle dogs. Surface topographies were investigated by confocal microscopy. Local tissue effects were evaluated at 4 and 13 weeks after implantation through histology. An ANOVA statistical analysis (5% risk; p < 0.05) was performed to compare peri-implant quantitative histomorphometric parameters on buccal and lingual sides, including Bone to Implant Contact (BIC) among test groups and time-periods. RESULTS Titanium and ceramic implants presented respectively moderate and minimal roughness. After 4 and 13 weeks, ceramic implants showed an inflammatory tissue response close to titanium implants. At both period of time there was no significant difference between the titanium and ceramic groups in terms of BIC values (mean ± SD) at the lingual or buccal sides or when combining buccal + lingual BIC values (respectively for titanium and ceramic, 68.4 ± 14.7 % and 75.0 ± 13.5 % at 4 weeks, and 92.0 ± 8.6 % and 86.1 ± 13.8 % at 13 weeks). SIGNIFICANCE Within the limits of the present study, it can be concluded that newly developed zirconia-based ceramic composite dental implants have similar biocompatibility and osseointegration to those observed in titanium implants. These pre-clinical results corroborate the potential for the use of these new zirconia-based ceramics in oral implantology.
Collapse
Affiliation(s)
- Doriane Chacun
- Université de Lyon, Lyon, Université Lyon 1, Laboratoire des Multimatériaux et Interfaces UMR CNRS 5615, Faculté d'Odontologie, 69372 Lyon Cedex 08, France; Hospices Civils de Lyon, Pôle d'Odontologie, Lyon, France
| | - Arnaud Lafon
- Université de Lyon, Lyon, Université Lyon 1, Laboratoire des Multimatériaux et Interfaces UMR CNRS 5615, Faculté d'Odontologie, 69372 Lyon Cedex 08, France; Hospices Civils de Lyon, Pôle d'Odontologie, Lyon, France
| | | | - Helen Reveron
- Université de Lyon, INSA-Lyon, MATEIS UMR CNRS 5510, 69621 Villeurbanne Cedex, France
| | - Jérôme Chevalier
- Université de Lyon, INSA-Lyon, MATEIS UMR CNRS 5510, 69621 Villeurbanne Cedex, France
| | - Patrice Margossian
- Exclusive Private Practice of Implantology and Periodontology, Marseille, France
| | | | - Kerstin Gritsch
- Université de Lyon, Lyon, Université Lyon 1, Laboratoire des Multimatériaux et Interfaces UMR CNRS 5615, Faculté d'Odontologie, 69372 Lyon Cedex 08, France; Hospices Civils de Lyon, Pôle d'Odontologie, Lyon, France
| | - Brigitte Grosgogeat
- Université de Lyon, Lyon, Université Lyon 1, Laboratoire des Multimatériaux et Interfaces UMR CNRS 5615, Faculté d'Odontologie, 69372 Lyon Cedex 08, France; Hospices Civils de Lyon, Pôle d'Odontologie, Lyon, France.
| |
Collapse
|
26
|
Cionca N, Hashim D, Mombelli A. Two-piece zirconia implants supporting all-ceramic crowns: Six-year results of a prospective cohort study. Clin Oral Implants Res 2021; 32:695-701. [PMID: 33638169 DOI: 10.1111/clr.13734] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 01/25/2021] [Accepted: 02/08/2021] [Indexed: 01/15/2023]
Abstract
OBJECTIVES The aim of this prospective clinical trial was to present the 6-year outcomes of a two-piece yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) implant system in partially edentulous patients. MATERIAL AND METHODS Forty-nine two-piece zirconia implants were placed in 32 patients systemically healthy. Zirconia abutments were connected with adhesive resin cement. Single-unit full-ceramic crowns were cemented. The cases have been followed for an average of 82.2 ± 5.86 months after loading (range 74.93-92.26 months). RESULTS 24 participants with 39 implants were available for examination 6 years after loading. The cumulative implant survival rate was 83%. On an implant level, the cumulative mechanical complication rate was 17.5%, the cumulative technical complication rate was 13%, and the biological complication rate was 8%. After 6 years, subjects reported good satisfaction with the treatment: 3.7 ± 4.4 on a visual analog scale (VAS) from 0 to 100 mm. CONCLUSIONS Within the limitations of this prospective case series study, two-piece zirconia implants could offer an alternative for treatment of single edentulous spaces in the posterior region. The major complication on the long term of this pioneering system was the abutment fracture; however, due to the versatility of a two-piece implant system, replacement of the broken parts was possible.
Collapse
Affiliation(s)
- Norbert Cionca
- Division of Regenerative Dental Medicine and Periodontology, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Dena Hashim
- Division of Regenerative Dental Medicine and Periodontology, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Andrea Mombelli
- Division of Regenerative Dental Medicine and Periodontology, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
27
|
Lorusso F, Noumbissi S, Francesco I, Rapone B, Khater AGA, Scarano A. Scientific Trends in Clinical Research on Zirconia Dental Implants: A Bibliometric Review. MATERIALS 2020; 13:ma13235534. [PMID: 33291827 PMCID: PMC7730252 DOI: 10.3390/ma13235534] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 11/29/2020] [Accepted: 12/02/2020] [Indexed: 12/13/2022]
Abstract
Background: The clinical use of zirconia implants has been shown to increase steadily due to their biological, aesthetic, and physical properties; therefore, this bibliometric study aimed to review the clinical research and co-authors in the field of zirconia dental implant rehabilitation. Methods: We searched Scopus and Web of Science databases using a comprehensive search strategy to 5 October 2020, and independently paired reviewers who screened studies, and collected data with inclusion criteria restricted to clinical research only (either prospective or retrospective). Data on article title, co-authors, number of citations received, journal details, publication year, country and institution involved, funding, study design, marginal bone loss, survival rate, failure, follow-up, and the author’s bibliometric data were collected and evaluated. Results: A total of 29 clinical studies were published between 2008 and 2020 as 41.4% were prospective cohort studies and 48.3% originated from Germany. Most of the included studies had been published in Clinical Oral Implant Research (n = 12), and the most productive institution was the Medical Center of University of Freiburg. The author with the largest number of clinical studies on zirconia implants was Kohal R.J. (n = 10), followed by Spies B.C. (n = 8). Conclusions: This study revealed that zirconia implants have been more prominent in the last ten years, which is a valuable option for oral rehabilitation with marginal bone loss and survival rate comparable to titanium dental implants.
Collapse
Affiliation(s)
- Felice Lorusso
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, 31, 66100 Chieti, Italy; (F.L.); (S.N.)
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA
| | - Sammy Noumbissi
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, 31, 66100 Chieti, Italy; (F.L.); (S.N.)
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA
| | - Inchingolo Francesco
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70121 Bari, Italy;
| | - Biagio Rapone
- Department of Basic Medical Sciences, Neurosciences and Sense Organs, University of Bari Aldo Moro, 70121 Bari, Italy;
| | - Ahmad G. A. Khater
- Faculty of Oral and Dental Medicine, Ahram Canadian University, 6th of October City, 8655 Giza, Egypt;
| | - Antonio Scarano
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, 31, 66100 Chieti, Italy; (F.L.); (S.N.)
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA
- Correspondence: ; Tel.: +39-0871-355-4084; Fax: +39-0871-355-4099
| |
Collapse
|
28
|
Munro T, Miller CM, Antunes E, Sharma D. Interactions of Osteoprogenitor Cells with a Novel Zirconia Implant Surface. J Funct Biomater 2020; 11:E50. [PMID: 32708701 PMCID: PMC7565437 DOI: 10.3390/jfb11030050] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 07/10/2020] [Accepted: 07/12/2020] [Indexed: 02/03/2023] Open
Abstract
Background: This study compared the in vitro response of a mouse pre-osteoblast cell line on a novel sandblasted zirconia surface with that of titanium. Material and Methods: The MC3T3-E1 subclone 4 osteoblast precursor cell line was cultured on either sandblasted titanium (SBCpTi) or sandblasted zirconia (SBY-TZP). The surface topography was analysed by three-dimensional laser microscopy and scanning electron microscope. The wettability of the discs was also assessed. The cellular response was quantified by assessing the morphology (day 1), proliferation (day 1, 3, 5, 7, 9), viability (day 1, 9), and migration (0, 6, 24 h) assays. Results: The sandblasting surface treatment in both titanium and zirconia increased the surface roughness by rendering a defined surface topography with titanium showing more apparent nano-topography. The wettability of the two surfaces showed no significant difference. The zirconia surface resulted in improved cellular spreading and a significantly increased rate of migration compared to titanium. However, the cellular proliferation and viability noted in our experiments were not significantly different on the zirconia and titanium surfaces. Conclusions: The novel, roughened zirconia surface elicited cellular responses comparable to, or exceeding that, of titanium. Therefore, this novel zirconia surface may be an acceptable substitute for titanium as a dental implant material.
Collapse
Affiliation(s)
- Thomas Munro
- College of Medicine and Dentistry, James Cook University, 14-88 McGregor Road, Smithfield 4878, QLD, Australia;
| | - Catherine M. Miller
- College of Public Health, Medical and Veterinary Sciences, James Cook University, 14-88 McGregor Road, Smithfield 4878, QLD, Australia;
- The Australian Institute of Tropical Health and Medicine (AITHM) James Cook University, 14-88 McGregor Road, Smithfield 4878, QLD, Australia
| | - Elsa Antunes
- College of Science & Engineering, James Cook University, 1 James Cook Drive, Douglas, Townsville 4814, QLD, Australia;
| | - Dileep Sharma
- College of Medicine and Dentistry, James Cook University, 14-88 McGregor Road, Smithfield 4878, QLD, Australia;
- The Australian Institute of Tropical Health and Medicine (AITHM) James Cook University, 14-88 McGregor Road, Smithfield 4878, QLD, Australia
| |
Collapse
|
29
|
Koller M, Steyer E, Theisen K, Stagnell S, Jakse N, Payer M. Two-piece zirconia versus titanium implants after 80 months: Clinical outcomes from a prospective randomized pilot trial. Clin Oral Implants Res 2020; 31:388-396. [PMID: 31944420 DOI: 10.1111/clr.13576] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Revised: 01/08/2020] [Accepted: 01/08/2020] [Indexed: 12/26/2022]
Abstract
OBJECTIVES To prospectively evaluate, as part of an ongoing randomized pilot trial, the clinical outcomes of two-piece zirconia implants in comparison with titanium implants 80 months after delivery of all-ceramic (lithium disilicate) single-tooth restorations. MATERIAL AND METHODS The original sample included 31 (16 zirconia and 15 titanium) implants in 22 healthy patients. In addition to evaluating implant survival and success, a number of clinical or radiographic parameters were statistically analyzed: plaque index (PI), bleeding on probing (BOP), pink esthetic score (PES), and marginal bone loss (MBL). Both implant groups were compared using a Mann-Whitney U test. RESULTS Three implants (2 zirconia and 1 titanium) had been lost, so that 28 implants (14 zirconia and 14 titanium) in 21 patients could be evaluated after a mean of 80.9 (SD: 5.5) months. All surviving implants had remained stable, in the absence of any fixture or abutment fractures and without any chipping, fracture, or debonding of crowns. The zirconia implants were associated with PI values of 11.07% (SD: 8.11) and the titanium implants with 15.20% (SD: 15.58), the respective figures for the other parameters being 16.43% (SD: 6.16) or 12.60% (SD: 7.66) for BOP; 11.11 (SD: 1.27) or 11.56 (SD: 1.01) for PES; and 1.38 mm (SD: 0.81) or 1.17 mm (SD: 0.73) for MBL. CONCLUSIONS No significant differences were found between the clinical outcomes of two-piece zirconia and titanium implants based on the aforementioned parameters after 80 months of clinical service. Our results should be interpreted with the limited sample size in mind.
Collapse
Affiliation(s)
- Martin Koller
- Division of Preventive and Operative Dentistry, Endodontics, Periodontology, Prosthodontics, Restorative Dentistry and Implantology, Department of Dental Medicine and Oral Health, School of Dentistry, Medical University Graz, Graz, Austria
| | - Elisabeth Steyer
- Division of Preventive and Operative Dentistry, Endodontics, Periodontology, Prosthodontics, Restorative Dentistry and Implantology, Department of Dental Medicine and Oral Health, School of Dentistry, Medical University Graz, Graz, Austria
| | - Kerstin Theisen
- Division of Preventive and Operative Dentistry, Endodontics, Periodontology, Prosthodontics, Restorative Dentistry and Implantology, Department of Dental Medicine and Oral Health, School of Dentistry, Medical University Graz, Graz, Austria
| | - Sami Stagnell
- Division of Oral Surgery and Orthodontics, Department of Dental Medicine and Oral Health, School of Dentistry, Medical University Graz, Graz, Austria
| | - Norbert Jakse
- Division of Oral Surgery and Orthodontics, Department of Dental Medicine and Oral Health, School of Dentistry, Medical University Graz, Graz, Austria
| | - Michael Payer
- Division of Oral Surgery and Orthodontics, Department of Dental Medicine and Oral Health, School of Dentistry, Medical University Graz, Graz, Austria
| |
Collapse
|
30
|
Qamar SA, Asgher M, Khalid N, Sadaf M. Nanobiotechnology in health sciences: Current applications and future perspectives. BIOCATALYSIS AND AGRICULTURAL BIOTECHNOLOGY 2019. [DOI: 10.1016/j.bcab.2019.101388] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
31
|
Esposito M, Ardebili Y, Worthington HV. WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants. Cochrane Database Syst Rev 2019; 10:CD003815. [PMID: 31600407 PMCID: PMC6786862 DOI: 10.1002/14651858.cd003815.pub5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Dental implants are available in different materials, shapes and with different surface characteristics. In particular, numerous implant designs and surface modifications have been developed for improving clinical outcome. This is an update of a Cochrane review first published in 2002, and previously updated in 2003, 2005 and 2007. OBJECTIVES Primary: to compare the clinical effects of different root-formed osseointegrated dental implant types for replacing missing teeth for the following specific comparisons: implants with different surface preparations, but having similar shape and material; implants with different shapes, but having similar surface preparation and material; implants made of different materials, but having similar surface preparation and shape; different implant types differing in surface preparation, shape, material or a combination of these.Secondary: to compare turned and roughened dental implants for occurrence of early implant failure (before prosthetic loading) and occurrence of peri-implantitis. SEARCH METHODS We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 17 January 2014), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 12), MEDLINE via OVID (1946 to 17 January 2014) and EMBASE via OVID (1980 to 17 January 2014). We placed no restrictions on the language or date of publication when searching the electronic databases. SELECTION CRITERIA We included any randomised controlled trial (RCT) comparing osseointegrated dental implants of different materials, shapes and surface properties having a follow-up in function of at least one year. Outcome measures were success of the implants, radiographic peri-implant marginal bone levels changes and incidence of peri-implantitis. DATA COLLECTION AND ANALYSIS At least two review authors independently conducted screening, risk of bias assessment and data extraction of eligible trials in duplicate. We expressed results using fixed-effect models (if up to three studies were present in a meta-analysis) or random-effects models (when there were more than three studies) using mean differences (MD) for continuous outcomes and risk ratios (RR) for dichotomous outcomes with 95% confidence intervals (CI). We reported the following endpoints: one, three, five and 10 years after functional loading. MAIN RESULTS We identified 81 different RCTs. We included 27 of these RCTs, reporting results from 1512 participants and 3230 implants in the review. We compared 38 different implant types with a follow-up ranging from one to 10 years. All implants were made of commercially pure titanium or its alloys, and had different shapes and surface preparations. We judged two trials to be at low risk of bias, 10 to be at unclear risk of bias and 15 to be at high risk of bias. On a 'per participant' rather than 'per implant' basis, we found no significant differences between various implant types for implant failures. The only observed statistically significant difference for the primary objective regarded more peri-implant bone loss at Nobel Speedy Groovy implants when compared with NobelActive implants (MD -0.59 mm; 95% CI -0.74 to -0.44, different implant shapes). The only observed statistically significant difference for the secondary objective was that implants with turned (smoother) surfaces had a 20% reduction in risk to be affected by peri-implantitis than implants with rough surfaces three years after loading (RR 0.80; 95% CI 0.67 to 0.96). There was a tendency for implants with turned surfaces to fail early more often than implants with roughened surfaces. AUTHORS' CONCLUSIONS Based on the results of the included RCTs, we found no evidence showing that any particular type of dental implant had superior long-term success. There was limited evidence showing that implants with relatively smooth (turned) surfaces were less prone to lose bone due to chronic infection (peri-implantitis) than implants with much rougher surfaces (titanium-plasma-sprayed). These findings were based on several RCTs, often at high risk of bias, with few participants and relatively short follow-up periods.
Collapse
Affiliation(s)
- Marco Esposito
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of ManchesterCochrane Oral HealthJR Moore Building, Oxford RoadManchesterUKM13 9PL
| | | | - Helen V Worthington
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of ManchesterCochrane Oral HealthJR Moore Building, Oxford RoadManchesterUKM13 9PL
| | | |
Collapse
|
32
|
ArRejaie AS, Al-Hamdan RS, Basunbul GI, Abduljabbar T, Al-Aali KA, Labban N. Clinical performance of one-piece zirconia dental implants: A systematic review. JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY 2018; 10:e12384. [PMID: 30588750 DOI: 10.1111/jicd.12384] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Accepted: 09/28/2018] [Indexed: 01/11/2023]
Abstract
The aim of the present review was to evaluate the clinical and radiographic performance of one-piece zirconia implants (O-PZI). This review followed the PRISMA (Preferred Reporting Items for Systematic Review and Meta-Analysis) guidelines that addressed the following focused question: What is the overall clinical and radiographic performance of O-PZI? The MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and Cochrane Oral Health Group Trials Register databases were searched. Six clinical studies were included. For studies evaluating O-PZI compared with one-piece titanium implants, zirconia implants showed higher crestal bone loss (CBL) in both the studies. However, one study demonstrated a high failure rate compared to titanium dental implants, while one study demonstrated comparable survival rates between zirconia and titanium dental implants. For studies evaluating O-PZI for the restoration of single crown and fixed dental prostheses, O-PZI showed comparable bone loss and survival rates for single crowns and fixed dental prostheses. Two studies were included that compared O-PZI with two-piece zirconia (T-PZI). One study showed a higher CBL and low survival rate for O-PZI compared to T-PZI, whereas the other study demonstrated comparable CBL and survival rates between O-PZI and T-PZI. It is still debatable whether O-PZI demonstrate better clinical performance when compared with titanium implants or two-piece design.
Collapse
Affiliation(s)
- Aws S ArRejaie
- Department of Prosthetic Dental Science, King Saud University, Riyadh, Saudi Arabia
| | - Rana S Al-Hamdan
- Department of Restorative Dental Science, King Saud University, Riyadh, Saudi Arabia
| | - Ghadeer I Basunbul
- Department of Oral and Maxillofacial Rehabilitation, Faculty of Dentistry, King Abdul Aziz University, Jeddah, Saudi Arabia
| | - Tariq Abduljabbar
- Department of Prosthetic Dental Science, King Saud University, Riyadh, Saudi Arabia
| | - Khulud A Al-Aali
- Department of Prosthodontics, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Nawaf Labban
- Department of Prosthetic Dental Science, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
33
|
Lopez CAV, Vasco MAA, Ruales E, Bedoya KA, Benfatti CM, Bezzon OL, Deliberador TM. Three-Dimensional Finite Element Analysis of Stress Distribution in Zirconia and Titanium Dental Implants. J ORAL IMPLANTOL 2018; 44:409-415. [DOI: 10.1563/aaid-joi-d-16-00109] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Zirconia has been presented as an alternative biomaterial to titanium, commercially presented as a single-body implant and/or as an abutment, demonstrating clinically biocompatible favorable results in white and rose esthetics. However, the number of long-term in vivo studies and mechanical tests evaluating the response of stress distribution compared with titanium implants is still limited. The aim of the study was to compare the principal peak stresses in the peri-implant bone around titanium and zirconia implants using the finite element method. Four groups of 3-dimensional models were constructed for the tests: G1, external hexagon titanium implant with a zirconia abutment; G2, zirconia implant with a zirconia abutment; G3, single-body titanium implant; and G4, single-body zirconia implant. Axial and oblique loads of 100 N at 45° were simulated in the prosthetic crown. The bone results showed that the peak stresses decreased by 12% in zirconia implants with 2 parts for axial load and 30% for the oblique load. In single-body implants, the peak stresses decreased 12% in the axial load and 34% in the oblique load when a zirconia implant was used compared with a titanium implant. Although the stress values in megapascals are similar, it can be concluded that the zirconia implants decrease the stress peaks at the peri-implant bone area around the implant platform when compared with titanium implants.
Collapse
Affiliation(s)
- Camilo Andres Villabona Lopez
- Department of Dentistry, Santo Tomás University, Bucaramanga, Santander, Colombia
- Faculty of Dentistry, SLMANDIC, Curitiba, PR, Brazil
| | - Marco Antônio Amorin Vasco
- Department of Oral Rehabilitation, University of São Paulo, Ribeirao Preto, Sao Paulo, Brazil
- Department of Bioengineering, University of Zaragoza, Zaragoza, Spain
| | - Edwin Ruales
- Center for Education and Research on Dental Implants (CEPID), Department of Implantology, Federal University of Santa Cataria, Florianópolis, Brazil
| | - Karin Apaza Bedoya
- Center for Education and Research on Dental Implants (CEPID), Department of Implantology, Federal University of Santa Cataria, Florianópolis, Brazil
| | - Cesar Magalhaes Benfatti
- Center for Education and Research on Dental Implants (CEPID), Department of Implantology, Federal University of Santa Cataria, Florianópolis, Brazil
| | - Osvaldo Luis Bezzon
- Department of Oral Rehabilitation, University of São Paulo, Ribeirao Preto, Sao Paulo, Brazil
- Department of Bioengineering, University of Zaragoza, Zaragoza, Spain
| | - Tatiana Miranda Deliberador
- Faculty of Dentistry, SLMANDIC, Curitiba, PR, Brazil
- Department of Dentistry, Positivo University, Curitiba, Paraná, Brazil
| |
Collapse
|
34
|
Roehling S, Schlegel KA, Woelfler H, Gahlert M. Performance and outcome of zirconia dental implants in clinical studies: A meta‐analysis. Clin Oral Implants Res 2018; 29 Suppl 16:135-153. [DOI: 10.1111/clr.13352] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 02/28/2018] [Accepted: 07/04/2018] [Indexed: 12/14/2022]
Affiliation(s)
- Stefan Roehling
- Clinic for Oral and Cranio‐Maxillofacial SurgeryHightech Research CenterUniversity Hospital BaselUniversity of Basel Basel Switzerland
- Clinic for Oral and Cranio‐Maxillofacial SurgeryKantonsspital Aarau Aarau Switzerland
- Unit for Oral & Maxillofacial SurgeryMedical Healthcare Center Lörrach Lörrach Germany
| | - Karl A. Schlegel
- Private Clinic for Oral and Maxillofacial Surgery Prof. Schlegel Munich Germany
- Maxillofacial Surgery DepartmentUniversity Hospital ErlangenUniversity of Erlangen Erlangen Germany
| | | | - Michael Gahlert
- Clinic for Oral and Cranio‐Maxillofacial SurgeryHightech Research CenterUniversity Hospital BaselUniversity of Basel Basel Switzerland
- Private Dental Clinic PD Dr. Gahlert Munich Germany
| |
Collapse
|
35
|
Payne AGT, Alsabeeha NHM, Atieh MA, Esposito M, Ma S, Anas El‐Wegoud M. Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws. Cochrane Database Syst Rev 2018; 10:CD008001. [PMID: 30308116 PMCID: PMC6516946 DOI: 10.1002/14651858.cd008001.pub2] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
BACKGROUND Implant overdentures are one of the most common treatment options used to rehabilitate edentulous patients. Attachment systems are used to anchor the overdentures to implants. The plethora of attachment systems available dictates a need for clinicians to understand their prosthodontic and patient-related outcomes. OBJECTIVES To compare different attachment systems for maxillary and mandibular implant overdentures by assessing prosthodontic success, prosthodontic maintenance, patient preference, patient satisfaction/quality of life and costs. SEARCH METHODS Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 24 January 2018); Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 12) in the Cochrane Library (searched 24 January 2018); MEDLINE Ovid (1946 to 24 January 2018); and Embase Ovid (1980 to 24 January 2018). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials on 24 January 2018. No restrictions were placed on the language or date of publication when searching the electronic databases. SELECTION CRITERIA All randomised controlled trials (RCTs), including cross-over trials on maxillary or mandibular implant overdentures with different attachment systems with at least 1 year follow-up. DATA COLLECTION AND ANALYSIS Four review authors extracted data independently and assessed risk of bias for each included trial. Several corresponding authors were subsequently contacted to obtain missing information. Fixed-effect meta-analysis was used to combine the outcomes with risk ratios (RR) for dichotomous outcomes and mean differences (MD) for continuous outcomes, with 95% confidence intervals (95% CI). We used the GRADE approach to assess the quality of evidence and create 'Summary of findings' tables. MAIN RESULTS We identified six RCTs with a total of 294 mandibular overdentures (including one cross-over trial). No trials on maxillary overdentures were eligible. Due to the poor reporting of the outcomes across the included trials, only limited analyses between mandibular overdenture attachment systems were possible.Comparing ball and bar attachments, upon pooling the data regarding short-term prosthodontic success, we identified substantial heterogeneity (I2 = 97%) with inconsistency in the direction of effect, which was unexplained by clinical or methodological differences between the studies, and accordingly we did not perform meta-analyses for this outcome. Short-term re-treatment (repair of attachment system) was higher with ball attachments (RR 3.11, 95% CI 1.68 to 5.75; 130 participants; 2 studies; very low-quality evidence), and there was no difference between both attachment systems in short-term re-treatment (replacement of attachment system) (RR 1.18, 95% CI 0.38 to 3.71; 130 participants; 2 studies; very low-quality evidence). It is uncertain whether there is a difference in short-term prosthodontic success when ball attachments are compared with bar attachments.Comparing ball and magnet attachments, there was no difference between them in medium-term prosthodontic success (RR 0.84, 95% CI 0.64 to 1.10; 69 participants; 1 study; very low-quality evidence), or in medium-term re-treatment (repair of attachment system) (RR 1.75, 95% CI 0.65 to 4.72; 69 participants; 1 study; very low-quality evidence). However, after 5 years, prosthodontic maintenance costs were higher when magnet attachments were used (MD -247.37 EUR, 95% CI -346.32 to -148.42; 69 participants; 1 study; very low-quality evidence). It is uncertain whether there is a difference in medium-term prosthodontic success when ball attachments are compared with magnet attachments.One trial provided data for ball versus telescopic attachments and reported no difference in prosthodontic maintenance between the two systems in short-term patrix replacement (RR 6.00, 95% CI 0.86 to 41.96; 22 participants; 1 study; very low-quality evidence), matrix activation (RR 11.00, 95% CI 0.68 to 177.72; 22 participants; 1 study; very low-quality evidence), matrix replacement (RR 1.75, 95% CI 0.71 to 4.31; 22 participants; 1 study; very low-quality evidence), or in relining of the implant overdenture (RR 2.33, 95% CI 0.81 to 6.76; 22 participants; 1 study; very low-quality evidence). It is uncertain whether there is a difference in short-term prosthodontic maintenance when ball attachments are compared with telescopic attachments.In the only cross-over trial included, patient preference between different attachment systems was assessed after only 3 months and not for the entire trial period of 10 years. AUTHORS' CONCLUSIONS For mandibular overdentures, there is insufficient evidence to determine the relative effectiveness of different attachment systems on prosthodontic success, prosthodontic maintenance, patient satisfaction, patient preference or costs. In the short term, there is some evidence that is insufficient to show a difference and where there was no evidence was reported. It was not possible to determine any preferred attachment system for mandibular overdentures.For maxillary overdentures, there is no evidence (with no trials identified) to determine the relative effectiveness of different attachment systems on prosthodontic success, prosthodontic maintenance, patient satisfaction, patient preference or costs.Further RCTs on edentulous cohorts must pay attention to trial design specifically using the same number of implants of the same implant system, but with different attachment systems clearly identified in control and test groups. Trials should also determine the longevity of different attachment systems and patient preferences. Trials on the current array of computer-aided designed/computer-assisted manufactured (CAD/CAM) bar attachment systems are encouraged.
Collapse
Affiliation(s)
- Alan GT Payne
- Northland Prosthodontics LtdPrivate practice17 Rust AvenueTown CentreWhangareiNorthlandNew Zealand0110
| | - Nabeel HM Alsabeeha
- RAK Dental Centre, Ministry of Health and PreventionRas Al‐KhaimahUnited Arab Emirates
| | - Momen A Atieh
- School of Dentistry, University of OtagoSir John Walsh Research InstituteDunedinNew Zealand
| | - Marco Esposito
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of ManchesterCochrane Oral HealthJR Moore Building, Oxford RoadManchesterUKM13 9PL
| | - Sunyoung Ma
- School of Dentistry, University of OtagoSir John Walsh Research InstituteDunedinNew Zealand
| | - Marwah Anas El‐Wegoud
- Egyptian Center for Evidence Based Medicine (ECEBM)8 Masaken Hayet El Tadrees Ain Shams University, El Khalifa El Maamoun St.CairoEgypt11646
| | | |
Collapse
|
36
|
Haro Adánez M, Nishihara H, Att W. A systematic review and meta-analysis on the clinical outcome of zirconia implant–restoration complex. J Prosthodont Res 2018; 62:397-406. [DOI: 10.1016/j.jpor.2018.04.007] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Revised: 04/20/2018] [Accepted: 04/26/2018] [Indexed: 11/26/2022]
|
37
|
Current status of zirconia implants in dentistry: preclinical tests. J Prosthodont Res 2018; 63:1-14. [PMID: 30205949 DOI: 10.1016/j.jpor.2018.07.006] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Revised: 07/18/2018] [Accepted: 07/26/2018] [Indexed: 11/23/2022]
Abstract
PURPOSE This systematic review aimed to provide an overview of zirconia implants as well as regarding the outcome of the implant-restorative complex in preclinical studies. STUDY SELECTION An electronic search of the literature prior to July 2017 was performed to identify all articles related to preclinical research on zirconia implants. The search was conducted using MEDLINE (National Library of Medicine) and PubMed without restrictions concerning the date of publication. The search terminology included: zirconia implant, osseointegration, bone-to-implant contact, soft tissue, histology, histomorphometry, surface modification, surface roughness, surface characteristics, and restoration (connecting multiple keywords with AND, OR). RESULTS Fifty-seven studies were finally selected from an initial yield of 654 titles, and the data were extracted. The identified preclinical studies focused on several aspects related to zirconia implants, namely biocompatibility, mechanical properties, implant design, osseointegration capacity, soft tissue response, and restorative options. Due to heterogeneity of the studies, a meta-analysis was not possible. The most frequently used zirconia material for the fabrication of implants is yttria-stabilized tetragonal zirconia polycrystal. The resistance-to-fracture for zirconia implants ranged between 516-2044N. The mostly investigated parameter was osseointegration, which is compared to that of titanium. A lack of evidence was found with other parameters. CONCLUSIONS Due to its good biocompatibility as well as favorable physical and mechanical properties, zirconia implants are a potential alternative to titanium implants. However, knowledge regarding the implant-restorative complex and related aspects is still immature to recommend its application for daily practice.
Collapse
|
38
|
|
39
|
Huang Z, Wang Z, Li C, Yin K, Hao D, Lan J. Application of Plasma-Sprayed Zirconia Coating in Dental Implants: Study in Implants. J ORAL IMPLANTOL 2018; 44:37-45. [DOI: 10.1563/aaid-joi-d-17-00020] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The aim was to investigate the osseointegration of a novel coating—plasma-sprayed nanostructured zirconia (NSZ)—for dental implants. Nanostructured zirconia coating on non-thread titanium implant was prepared by plasma spraying, and the implant surface morphology, surface roughness, and wettability were measured. In vivo, nanostructured zirconia-coated implants were inserted in rabbit tibia, and the animals were sacrificed at 2, 4, 8, and 12 weeks after implantation. The bond strength between implant and bone was measured with the removal torque (RTQ) test. Osseointegration was observed by scanning electron microscopy (SEM), microcomputerized tomography (micro CT), and histological analyses. Quantified parameters were calculated, including removal torque, bone volume to tissue volume (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), trabecular separation/spacing (Tb.Sp), and bone-implant contact (BIC) percentage. The statistical differences were detected with a two-tail Mann-Whitney U test (SPSS 20.0). The surface roughness (1.58 μm) and wettability (54.61°) of a nanostructured zirconia-coated implant was more suitable than the titanium implant (0.598 μm, 74.38°) for osseointegration and hierarchical surface morphology seen on the zirconia coating. The histological analyses showed that a zirconia-coated implant induced earlier and had more condensed bone formation than did the titanium implant at 2 and 4 weeks. Quantified parameters showed the significant differences between these 2 groups at an early healing period, but the differences between the 2 groups decreased with an increased healing period. All these results demonstrated that plasma-sprayed zirconia coated implants induced better bone formation than did titanium implants at an early stage.
Collapse
Affiliation(s)
- Zhengfei Huang
- School of Stomatology, Shandong University, Jinan, China
- Shandong Provincial Key Laboratory of Oral Biomedicine, Jinan, China
| | - Zhifeng Wang
- Department of Pediatric Dentistry, School of Stomatology, Shandong University, Jinan, China
| | - Chuanhua Li
- Department of Prosthodontics, School of Stomatology, Shandong University, Jinan, China
| | - Kaifeng Yin
- Department of Orthodontics, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, Calif
| | - Dan Hao
- Nantong Stomatological Hospital, Nantong, China
| | - Jing Lan
- Department of Prosthodontics, School of Stomatology, Shandong University, Jinan, China
| |
Collapse
|
40
|
Ultimate force and stiffness of 2-piece zirconium dioxide implants with screw-retained monolithic lithium-disilicate reconstructions. J Prosthodont Res 2018; 62:258-263. [DOI: 10.1016/j.jpor.2017.11.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Revised: 09/01/2017] [Accepted: 11/13/2017] [Indexed: 11/21/2022]
|
41
|
Martins R, Cestari TM, Arantes RVN, Santos PS, Taga R, Carbonari MJ, Oliveira RC. Osseointegration of zirconia and titanium implants in a rabbit tibiae model evaluated by microtomography, histomorphometry and fluorochrome labeling analyses. J Periodontal Res 2017; 53:210-221. [PMID: 29044523 DOI: 10.1111/jre.12508] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/01/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVES This study compares the osseointegration of machined-zirconia implants containing yttria (M-Y-TZP) with machined (M-Ti) and resorbable blast media (RBM-Ti) titanium implants. MATERIAL AND METHODS M-Y-TZP, M-Ti and RBM-Ti implants were randomly placed in rabbit tibiae. Fluorochrome bone labels (tetracycline, alizarin and calcein) were administered at different time periods. After 8 weeks, osseointegration was evaluated in terms of bone-to-implant contact (BIC), new bone area (nBA), remaining cortical bone area (rBA) and temporal quantification of fluorochromes, using micro-CT and histomorphometric analyses. RESULTS RBM-Ti implants showed higher resorption of the remaining cortical bone and bone formation (rBA = 36.9% and nBA = 38.8%) than M-Y-TZP implants (rBA = 48% and nBA = 26.5%). The BIC values showed no differences among the groups in the cortical region (mean = 52.2%) but in the medullary region, they were 0.45-fold higher in the RBM-Ti group (51.2%) than in the M-Y-TZP group (35.2%). In all groups, high incorporation of tetracycline was observed (2nd to 4th weeks), followed by alizarin (4th to 6th weeks) and calcein (6th to 8th weeks). In the cortical region, incorporation of tetracycline was similar between RBM-Ti (49.8%) and M-Y-TZP (35.9%) implants, but higher than M-Ti (28.2%) implants. Subsequently, alizarin and calcein were 1.1-fold higher in RBM-Ti implants than in the other implants. In the medullary region, no significant differences were observed for all fluorochromes. CONCLUSION All implants favored bone formation and consequently promoted primary stability. Bone formation around the threads was faster in RBM-Ti and M-Y-TZP implants than in M-Ti implants, but limited bone remodeling with M-Y-TZP implants over time can have significant effects on secondary stability, suggesting caution for its use as an alternative substitute for titanium implants.
Collapse
Affiliation(s)
- R Martins
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - T M Cestari
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - R V N Arantes
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - P S Santos
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - R Taga
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - M J Carbonari
- Insper - Instituto de Ensino e Pesquisa, São Paulo, SP, Brazil
| | - R C Oliveira
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| |
Collapse
|
42
|
Velázquez-Cayón R, Castillo-Dalí G, Corcuera-Flores JR, Serrera-Figallo MA, Castillo-Oyagüe R, González-Martín M, Gutierrez-Pérez JL, Torres-Lagares D. Production of bone mineral material and BMP-2 in osteoblasts cultured on double acid-etched titanium. Med Oral Patol Oral Cir Bucal 2017; 22:e651-e659. [PMID: 28809380 PMCID: PMC5694190 DOI: 10.4317/medoral.22071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Accepted: 06/23/2017] [Indexed: 11/30/2022] Open
Abstract
Background The study of osteoblasts and their osteogenic functions is essential in order to understand them and their applications in implantology. In this sense, this study try to study BMP-2 production and bone matrix deposition, in addition to other biological variables, in osteoblasts cultured on a rough double acid-etched titanium surface (Osseotite®, Biomet 3i, Palm Beach Garden, Florida, USA) in comparison to a smooth titanium surface (machined) and a control Petri dish. Material and Methods An in vitro prospective study. NHOst human osteoblasts from the femur were cultured on three different surfaces: Control group: 25-mm methacrylate dish (n = 6); Machined group: titanium discs with machined surface (n = 6) and Experimental group: titanium discs with a double acid-etched nitric and hydrofluoric Osseotite® acid surface (n = 6). A quantification of the mitochondrial membrane potential, and studies of apoptosis, mobility and adhesion, bone productivity (BMP-2) and cellular bone synthesis were carried out after culturing the three groups for forty-eight hours. Results A statistically significant difference was observed in the production of BMP-2 between the experimental group and the other two groups (22.33% ± 11.06 vs. 13.10% ± 5.51 in the machined group and 3.88% ± 3.43 in the control group). Differences in cellular bone synthesis were also observed between the groups (28.34% ± 14.4% in the experimental group vs. 20.03% ± 6.79 in the machined group and 19.34% ± 15.93% in the control group). Conclusions In comparison with machined surfaces, Osseotite® surfaces favor BMP-2 production and bone synthesis as a result of the osteoblasts in contact with it. Key words:BMP-2, Cytoskeleton, cell culture, bone matrix, apoptosis, cell viability.
Collapse
Affiliation(s)
- R Velázquez-Cayón
- School of Dentistry. University of Seville, C/Avicena s/n, 41009 Seville,
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Sivaraman K, Chopra A, Narayan AI, Balakrishnan D. Is zirconia a viable alternative to titanium for oral implant? A critical review. J Prosthodont Res 2017; 62:121-133. [PMID: 28827030 DOI: 10.1016/j.jpor.2017.07.003] [Citation(s) in RCA: 121] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 06/22/2017] [Accepted: 07/11/2017] [Indexed: 02/04/2023]
Abstract
PURPOSE Titanium based implant systems, though considered as the gold standard for rehabilitation of edentulous spaces, have been criticized for many inherent flaws. The onset of hypersensitivity reactions, biocompatibility issues, and an unaesthetic gray hue have raised demands for more aesthetic and tissue compatible material for implant fabrication. Zirconia is emerging as a promising alternative to conventional Titanium based implant systems for oral rehabilitation with superior biological, aesthetics, mechanical and optical properties. This review aims to critically analyze and review the credibility of Zirconia implants as an alternative to Titanium for prosthetic rehabilitation. STUDY SELECTION The literature search for articles written in the English language in PubMed and Cochrane Library database from 1990 till December 2016. The following search terms were utilized for data search: "zirconia implants" NOT "abutment", "zirconia implants" AND "titanium implants" AND "osseointegration", "zirconia implants" AND compatibility. RESULTS The number of potential relevant articles selected were 47. All the human in vivo clinical, in vitro, animals' studies were included and discussed under the following subheadings: Chemical composition, structure and phases; Physical and mechanical properties; Aesthetic and optical properties; Osseointegration and biocompatibility; Surface modifications; Peri-implant tissue compatibility, inflammation and soft tissue healing, and long-term prognosis. CONCLUSIONS Zirconia implants are a promising alternative to titanium with a superior soft-tissue response, biocompatibility, and aesthetics with comparable osseointegration. However, further long-term longitudinal and comparative clinical trials are required to validate zirconia as a viable alternative to the titanium implant.
Collapse
Affiliation(s)
- Karthik Sivaraman
- Department of Prosthodontics, Manipal College of Dental Sciences, Manipal University, Manipal, 576104, India.
| | - Aditi Chopra
- Department of Periodontology, Manipal College of Dental Sciences, Manipal University, Manipal, India
| | - Aparna I Narayan
- Department of Prosthodontics, Manipal College of Dental Sciences, Manipal University, Manipal, 576104, India
| | - Dhanasekar Balakrishnan
- Department of Prosthodontics, Manipal College of Dental Sciences, Manipal University, Manipal, 576104, India
| |
Collapse
|
44
|
Atieh MA, Tawse-Smith A, Alsabeeha NHM, Ma S, Duncan WJ. The One Abutment-One Time Protocol: A Systematic Review and Meta-Analysis. J Periodontol 2017. [PMID: 28625076 DOI: 10.1902/jop.2017.170238] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND The use of definitive abutments (DAs) at time of implant placement has been introduced to overcome limitations of dis/reconnection of healing/provisional abutments (PAs). With little and inconsistent information in the literature regarding the effectiveness of using DAs, the aim of this systematic review is to examine marginal bone and soft tissue level changes, technical and biologic complications, and implant failure rate associated with use of DAs and PAs. METHODS This systematic review was prepared according to guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and online trial registers were searched for studies comparing use of DAs and PAs. The Cochrane Collaboration risk of bias tool was used to assess selected studies, and meta-analyses were performed using statistical software. RESULTS A total of 1,124 citations were identified. Of these, seven trials with 363 dental implants in 262 participants were included in the analysis. Pooled estimates for marginal bone level changes showed significant differences between the two prosthetic techniques in favor of using DAs. No significant differences were found in soft tissue level changes, technical and biologic complications, or implant failure rate. CONCLUSIONS Within the limitations of this review, DAs appear to be a viable alternative to PAs at time of implant placement. However, favorable changes in peri-implant marginal bone level associated with use of DAs should be viewed with caution as its clinical significance is still uncertain.
Collapse
Affiliation(s)
- Momen A Atieh
- Oral Implantology Research Group, Sir John Walsh Research Institute, University of Otago, Dunedin, New Zealand.,Department of Oral Sciences, Faculty of Dentistry, University of Otago
| | - Andrew Tawse-Smith
- Oral Implantology Research Group, Sir John Walsh Research Institute, University of Otago, Dunedin, New Zealand.,Department of Oral Sciences, Faculty of Dentistry, University of Otago
| | - Nabeel H M Alsabeeha
- Prosthetic Section, Ras Al-Khaimah Dental Center, Ministry of Health, Ras Al-Khaimah, United Arab Emirates
| | - Sunyoung Ma
- Oral Implantology Research Group, Sir John Walsh Research Institute, University of Otago, Dunedin, New Zealand
| | - Warwick J Duncan
- Oral Implantology Research Group, Sir John Walsh Research Institute, University of Otago, Dunedin, New Zealand.,Department of Oral Sciences, Faculty of Dentistry, University of Otago
| |
Collapse
|
45
|
Cionca N, Hashim D, Mombelli A. Zirconia dental implants: where are we now, and where are we heading? Periodontol 2000 2016; 73:241-258. [DOI: 10.1111/prd.12180] [Citation(s) in RCA: 141] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
46
|
One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study. BIOMED RESEARCH INTERNATIONAL 2016; 2016:6792972. [PMID: 28058261 PMCID: PMC5183747 DOI: 10.1155/2016/6792972] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2016] [Revised: 10/17/2016] [Accepted: 11/08/2016] [Indexed: 11/17/2022]
Abstract
Reports have documented titanium (Ti) hypersensitivity after dental implant treatment. Alternative materials have been suggested including zirconia (Zr) ceramics, which have shown predictable osseointegration in animal studies and appear free of immune responses. The aim of the research was to investigate the bone-to-implant contact (BIC) of one-piece Zr, compared with one-piece Ti implants, placed in the jaws and femurs of domestic sheep. Ten New Zealand mixed breed sheep were used. A One-piece prototype Ti (control) and one Zr (test) implant were placed in the mandible, and one of each implant (Ti and Zr) was placed into the femoral epicondyle of each animal. The femur implants were submerged and unloaded; the mandibular implants were placed using a one-stage transgingival protocol and were nonsubmerged. After a healing period of 12 weeks, %BIC was measured. The overall survival rate for mandibular and femur implants combined was 87.5%. %BIC was higher for Zr implants versus Ti implants in the femur (85.5%, versus 78.9%) (p = 0.002). Zirconia implants in the mandible showed comparable %BIC to titanium implants (72.2%, versus 60.3%) (p = 0.087). High failure rate of both Zr and Ti one-piece implants in the jaw could be attributed to the one-piece design and surface characteristics of the implant that could have influenced osseointegration. Further clinical trials are recommended to evaluate the performance of zirconia implants under loading conditions.
Collapse
|
47
|
Han JM, Hong G, Lin H, Shimizu Y, Wu Y, Zheng G, Zhang H, Sasaki K. Biomechanical and histological evaluation of the osseointegration capacity of two types of zirconia implant. Int J Nanomedicine 2016; 11:6507-6516. [PMID: 27994456 PMCID: PMC5153287 DOI: 10.2147/ijn.s119519] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The purpose of this study was to evaluate the biomechanical and histological behavior of a ceria-stabilized zirconia-alumina nanocomposite (NanoZr) in comparison with that of 3 mol% yttria-stabilized tetragonal zirconia polycrystalline (3Y-TZP) in Sprague Dawley rats. Cylindrical NanoZr and 3Y-TZP implants (diameter 1 mm, length 2 mm) were used. Implant-surface morphology and surface roughness were determined by scanning white-light interferometry and scanning electron microscopy, respectively. The cylindrical zirconia implants were placed at the distal edge of the femur of Sprague Dawley rats. At weeks 2, 4, and 8, the interfacial shear strength between implant and bone was measured by push-in test. Histological analysis was performed using hard-tissue sections. Bone-implant contact (BIC), the thickness of new bone around the implant within the bone marrow area, and osteoclast numbers were evaluated. The average surface roughness of 3Y-TZP (Sa 0.788 μm) was significantly higher than that of NanoZr (Sa 0.559 μm). The shear strengths of 3Y-TZP and NanoZr were similar at 2 weeks, but at 4 and 8 weeks the shear strength of NanoZr was higher than that of 3Y-TZP. The average BIC values within the bone marrow area for 3Y-TZP and NanoZr were 25.26% and 31.51% at 2 weeks, 46.78% and 38% at 4 weeks, and 47.88% and 56.81% at 8 weeks, respectively. The average BIC values within the cortical area were 38.86% and 58.42% at 2 weeks, 66.82% and 57.74% at 4 weeks, and 79.91% and 78.97% at 8 weeks, respectively. The mean BIC value did not differ significantly between the two zirconia materials at any time point. The NanoZr implants were biocompatible, capable of establishing close BIC, and may be preferred for metal-free dental implants.
Collapse
Affiliation(s)
- Jian-min Han
- Department of Dental Materials, National Engineering Laboratory for Digital and Material Technology of Stomatology, Peking University School and Hospital of Stomatology, Beijing, People’s Republic of China
- Division of Advanced Prosthetic Dentistry
| | | | - Hong Lin
- Department of Dental Materials, National Engineering Laboratory for Digital and Material Technology of Stomatology, Peking University School and Hospital of Stomatology, Beijing, People’s Republic of China
| | - Yoshinaka Shimizu
- Department of Oral Pathology, Graduate School of Dentistry, Tohoku University, Sendai, Japan
| | - Yuhan Wu
- Division of Advanced Prosthetic Dentistry
| | - Gang Zheng
- Department of Dental Materials, National Engineering Laboratory for Digital and Material Technology of Stomatology, Peking University School and Hospital of Stomatology, Beijing, People’s Republic of China
| | - Hongyu Zhang
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, People’s Republic of China
| | | |
Collapse
|
48
|
Flamant Q, Stanciuc AM, Pavailler H, Sprecher CM, Alini M, Peroglio M, Anglada M. Roughness gradients on zirconia for rapid screening of cell-surface interactions: Fabrication, characterization and application. J Biomed Mater Res A 2016; 104:2502-14. [PMID: 27227541 DOI: 10.1002/jbm.a.35791] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Revised: 05/21/2016] [Accepted: 05/24/2016] [Indexed: 12/23/2022]
Abstract
Roughness is one of the key parameters for successful osseointegration of dental implants. The understanding of how roughness affects cell response is thus crucial to improve implant performance. Surface gradients, which allow rapid and systematic investigations of cell-surface interactions, have the potential to facilitate this task. In this study, a novel method aiming to produce roughness gradients at the surface of zirconia using hydrofluoric acid etching was implemented. The topography was exhaustively characterized at the microscale and nanoscale by white light interferometry and atomic force microscopy, including the analysis of amplitude, spatial, hybrid, functional, and fractal parameters. A rapid screening of the influence of roughness on human mesenchymal stem cell morphology was conducted and potential correlations between roughness parameters and cell morphology were investigated. The roughness gradient induced significant changes in cell area (p < 0.001), aspect ratio (p = 0.01), and solidity (p = 0.026). Nanoroughness parameters were linearly correlated to cell solidity (p < 0.005), while microroughness parameters appeared nonlinearly correlated to cell area, highlighting the importance of multiscale optimization of implant topography to induce the desired cell response. The gradient method proposed here drastically reduces the efforts and resources necessary to study cell-surface interactions and provides results directly transferable to industry. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2502-2514, 2016.
Collapse
Affiliation(s)
- Quentin Flamant
- Department of Materials Science and Metallurgical Engineering, Universitat Politècnica De Catalunya, Av. Diagonal 647, Barcelona, 08028, Spain.,Center for Research in Nano-Engineering, CRNE, Universitat Politècnica De Catalunya, C. Pascual I Vila, 15, Barcelona, 08028, Spain
| | - Ana-Maria Stanciuc
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos Platz, Switzerland
| | - Hugo Pavailler
- Department of Materials Science and Metallurgical Engineering, Universitat Politècnica De Catalunya, Av. Diagonal 647, Barcelona, 08028, Spain
| | | | - Mauro Alini
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos Platz, Switzerland
| | - Marianna Peroglio
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos Platz, Switzerland
| | - Marc Anglada
- Department of Materials Science and Metallurgical Engineering, Universitat Politècnica De Catalunya, Av. Diagonal 647, Barcelona, 08028, Spain.,Center for Research in Nano-Engineering, CRNE, Universitat Politècnica De Catalunya, C. Pascual I Vila, 15, Barcelona, 08028, Spain
| |
Collapse
|
49
|
Hashim D, Cionca N, Courvoisier DS, Mombelli A. A systematic review of the clinical survival of zirconia implants. Clin Oral Investig 2016; 20:1403-17. [PMID: 27217032 PMCID: PMC4992030 DOI: 10.1007/s00784-016-1853-9] [Citation(s) in RCA: 95] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Accepted: 05/06/2016] [Indexed: 12/29/2022]
Abstract
OBJECTIVES The aim of this review was to evaluate the clinical success and survival rates of zirconia ceramic implants after at least 1 year of function and to assess if there is sufficient evidence to justify using them as alternatives to titanium implants. MATERIALS AND METHODS An electronic search in MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Clinical Trials (CENTRAL) databases was performed in April 2015 by two independent examiners to retrieve clinical studies focusing on the survival rate of zirconia implants after at least 1 year of function. Implant survival was estimated using the overall proportion reported in the studies with a Clopper-Pearson 95 % confidence interval (random effect model with a Der-Simonian Laird estimate). RESULTS Fourteen articles were selected out of the 1519 titles initially screened. The overall survival rate of zirconia one- and two-piece implants was calculated at 92 % (95 % CI 87-95) after 1 year of function. The survival of implants at 1 year for the selected studies revealed considerable heterogeneity. CONCLUSIONS In spite of the unavailability of sufficient long-term evidence to justify using zirconia oral implants, zirconia ceramics could potentially be the alternative to titanium for a non-metallic implant solution. However, further clinical studies are required to establish long-term results, and to determine the risk of technical and biological complications. Additional randomized controlled clinical trials examining two-piece zirconia implant systems are also required to assess their survival and success rates in comparison with titanium as well as one-piece zirconia implants. CLINICAL RELEVANCE Zirconia implants provide a potential alternative to titanium ones. However, clinicians must be aware of the lack of knowledge regarding long-term outcomes and specific reasons for failure.
Collapse
Affiliation(s)
- Dena Hashim
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthelemy-Menn 19, CH-1205, Geneva, Switzerland.
| | - Norbert Cionca
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthelemy-Menn 19, CH-1205, Geneva, Switzerland
| | - Delphine S Courvoisier
- University Hospitals of Geneva, Rue Gabrielle-Perret-Gentil 4, CH-1205, Genève, Switzerland
| | - Andrea Mombelli
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthelemy-Menn 19, CH-1205, Geneva, Switzerland
| |
Collapse
|
50
|
Crestal bone loss and periimplant inflammatory parameters around zirconia implants: A systematic review. J Prosthet Dent 2015; 114:351-7. [PMID: 26047803 DOI: 10.1016/j.prosdent.2015.03.016] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2014] [Revised: 03/25/2015] [Accepted: 03/26/2015] [Indexed: 01/28/2023]
Abstract
STATEMENT OF PROBLEM Zirconia implants have been used for oral rehabilitation; however, evidence of their ability to maintain crestal bone and periimplant soft tissue health is not clear. PURPOSE The purpose of this systematic review was to evaluate crestal bone loss (CBL) around zirconia dental implants and clinical periimplant inflammatory parameters. MATERIAL AND METHODS The focus question addressed was, "Do zirconia implants maintain crestal bone levels and periimplant soft tissue health?" Databases were searched for articles from 1977 through September 2014 with different combinations of the following MeSH terms: "dental implants," "zirconium," "alveolar bone loss," "periodontal attachment loss," "periodontal pocket," "periodontal index." Letters to the editor, case reports, commentaries, review articles, and articles published in languages other than English were excluded. RESULTS Thirteen clinical studies were included. In 8 of the studies, the CBL around zirconia implants was comparable between baseline and follow-up. In the other 5 studies, the CBL around zirconia implants was significantly higher at follow-up. Among the studies that used titanium implants as controls, 2 studies showed significantly higher CBL around zirconia implants, and in 1 study, the CBL around zirconia and titanium implants was comparable. The reported implant survival rates for zirconia implants ranged between 67.6% and 100%. Eleven studies selectively reported the periimplant inflammatory parameters. CONCLUSIONS Because of the variations in study design and methodology, it was difficult to reach a consensus regarding the efficacy of zirconia implants in maintaining crestal bone levels and periimplant soft tissue health.
Collapse
|