1
|
Aydın U, Özdemir M, Çulha E, Baştürk Özer MN, Turan B. Evaluation of Cyclic Fatigue Resistance of Novel Replica-Like Instruments in Static Test Model. Appl Bionics Biomech 2024; 2024:8842478. [PMID: 39206445 PMCID: PMC11357823 DOI: 10.1155/2024/8842478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Accepted: 08/06/2024] [Indexed: 09/04/2024] Open
Abstract
Introduction The aim of our study is to comparatively analyze the canal cyclic fatigue resistance of widely used rotary file systems, including EndoArt Touch Gold (ETG), Perfect MTF Plus Gold (PPG), Fanta V-Taper Gold (FVG), and ProTaper Next (PTN). Methods Stainless steel canals with a 60° angle and a 3-mm curvature radius were specially prepared. The canals were shaped with each rotary file system and tested for resistance using a cyclic fatigue testing apparatus. The number of fracture cycles (NFC; K file tip separation) was measured. Data were analysed by one-way ANOVA and post hoc LSD tests. Results PTN and PPG rotary file systems exhibited the highest NFC. The NFC value for PTN was 589 ± 63, and for PPG, it was 507 ± 51. Conclusion The results of this study demonstrate that rotary file systems such as PTN and PPG exhibit higher cyclic fatigue resistance. ETG and FVG rotary file systems also possess generally acceptable cyclic fatigue resistance levels.
Collapse
Affiliation(s)
- Uğur Aydın
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| | - Melih Özdemir
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| | - Emre Çulha
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| | | | - Bilal Turan
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| |
Collapse
|
2
|
Subramanian V, Roberts HW, Han S, Sidow SJ, Berzins DW. Electrochemical Properties of Nickel-Titanium Rotary Endodontic Instruments. J Endod 2024; 50:1143-1150. [PMID: 38762142 DOI: 10.1016/j.joen.2024.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 04/26/2024] [Accepted: 05/09/2024] [Indexed: 05/20/2024]
Abstract
INTRODUCTION Nickel-titanium rotary endodontic files have been commercially available for decades, but more recent innovations have introduced heat-treated and surface-treated files. This study investigated the corrosion properties of various nickel-titanium files in normal saline and sodium hypochlorite (NaOCl). METHODS Ten different file brands of size 40 with a 0.04 taper were subjected to electrochemical testing in 0.9% NaCl (saline) and 5.25% NaOCl at room temperature. The Open Circuit Potential (OCP) was observed for 1 hour followed by a cyclic polarization test from -300 to 700 mV and back to -300 mV (vs OCP). Nonparametric ANOVA and a pairwise comparison (P < .05) were used for statistical analysis of the OCP at 1 hour and the corrosion current (Icorr) obtained via the cyclic polarization test. RESULTS Significant differences (P < .05) were found between files with respect to OCP and Icorr in both solutions. Nine files exhibited significantly greater (P < .05) Icorrs in NaOCl than in saline. Conversely, pitting corrosion was observed in the saline solution but not NaOCl. Weak and/or moderate correlations existed between OCP and Icorr measures in the 2 solutions. CONCLUSION Significant differences in electrochemical properties were observed among the 10 brands of files. Overall, there was not a clear trend between conventional, heat-treated, or surface-treated files among OCP or Icorr in either solution.
Collapse
Affiliation(s)
- Vidyalakshmi Subramanian
- Department of General Dental Sciences-Dental Biomaterials Marquette University School of Dentistry, Milwaukee, Wisconsin
| | - Howard W Roberts
- Department of General Dental Sciences-Dental Biomaterials, Marquette University School of Dentistry, Milwaukee, Wisconsin and University of Kentucky College of Dentistry, Lexington, Kentucky
| | - Shengtong Han
- Department of General Dental Sciences-Biostatistics, Marquette University School of Dentistry, Milwaukee, Wisconsin
| | - Stephanie J Sidow
- Department of Surgical and Diagnostic Sciences-Endodontics, Marquette University School of Dentistry, Milwaukee, Wisconsin
| | - David W Berzins
- Department of General Dental Sciences-Dental Biomaterials, Marquette University School of Dentistry, Milwaukee, Wisconsin.
| |
Collapse
|
3
|
Al Omari T, Atmeh AR, Algahtani FN, Dkmak A, Albanna RHI, Tabnjh A. The effect of irrigation solution temperature and novel heat-treated rotary files on apical debris extrusion and canal preparation time. AUST ENDOD J 2024. [PMID: 39022875 DOI: 10.1111/aej.12878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 06/27/2024] [Accepted: 07/07/2024] [Indexed: 07/20/2024]
Abstract
This study aimed to compare apical debris extrusion and canal preparation time with ProTaper Gold (PTG) and ProTaper Ultimate (PTU) files at different temperatures. Mesio-buccal roots of 60 mandibular first molars were distributed into six groups depending on the file type (PTG, PTU) and irrigation solution temperature (20, 37, 45°C). During instrumentation, extruded debris were collected and weighed to measure the mass in milligrams. The canal preparation time was recorded in seconds. ANOVA followed by Bonferroni post-hoc tests were used for analysis. The amount of debris extrusion was significantly higher in PTU, which was affected by the irrigation solution temperature (p < 0.05). The difference in canal preparation time was not significant between the two file systems, however, it was significant between the different temperatures (p = 0.001). Both file systems had shorter canal preparation times at 20°C. The irrigation solution temperature could influence the debris extrusion and time of canal preparation.
Collapse
Affiliation(s)
- Taher Al Omari
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Amre R Atmeh
- Hamdan Bin Mohammed College of Dental Medicine (HBMCDM), Mohammed Bin Rashid University of Medicine and Health Sciences (MBRU), Dubai, United Arab Emirates
| | - Fahda N Algahtani
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Alaa Dkmak
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Rami Haitham Issa Albanna
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Abedelmalek Tabnjh
- Department of Applied Dental Sciences, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| |
Collapse
|
4
|
Youssef E, Jungbluth H, Jepsen S, Gruener M, Bourauel C. Comparing Cyclic Fatigue Resistance and Free Recovery Transformation Temperature of NiTi Endodontic Single-File Systems Using a Novel Testing Setup. MATERIALS (BASEL, SWITZERLAND) 2024; 17:566. [PMID: 38591373 PMCID: PMC10856488 DOI: 10.3390/ma17030566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 01/05/2024] [Accepted: 01/22/2024] [Indexed: 04/10/2024]
Abstract
The aim of this study was to assess the effect of body temperature (37 °C) on the cyclic fatigue resistance of three endodontic single-file systems using a new testing setup. One Shape® new generation (OS), WaveOne™ (WO) and WaveOne® GOLD (WOG), which are made from different NiTi alloys and operated in different motions (rotation/reciprocation), were evaluated. The study design included four groups. Each group comprised 30 files, 10 files of each of the three file systems, tested at 20 ± 2 °C (group 1 and 3) and at 37 ± 1 °C (group 2 and 4). All files were tested in a custom-made metal block with artificial canals of 60° angle, and a 5 mm and 3 mm radius of curvature, respectively. A heating element was attached to replicate a temperature of 37 °C. Files were introduced 18 mm into the canals and operated until failure. Transformation temperatures of five samples of each of the tested file systems were determined via the bend and free recovery (BFR) method. With the exception of WOG in canals with a 3 mm radius of curvature (p = 0.075), all the tested file systems showed statistically significantly less time needed to fracture when operated at 37 ± 1 °C compared to at 20 ± 2 °C in canals with a 5 mm and 3 mm radius of curvature using Mann-Whitney U test (p < 0.05). All file systems showed transformation temperatures below the body temperature. We concluded that body temperature directly affects the cyclic fatigue resistance of all tested file systems. Bend and free recovery can be suitable for the determination of austenite finish temperatures (Af) of endodontic instruments as it allows testing a longer portion of the instrument.
Collapse
Affiliation(s)
- Emad Youssef
- Department of Periodontology, Operative and Preventive Dentistry, University of Bonn, 53111 Bonn, Germany
- Department of Oral Technology, Faculty of Medicine, University of Bonn, 53111 Bonn, Germany
| | - Holger Jungbluth
- Department of Periodontology, Operative and Preventive Dentistry, University of Bonn, 53111 Bonn, Germany
| | - Søren Jepsen
- Department of Periodontology, Operative and Preventive Dentistry, University of Bonn, 53111 Bonn, Germany
| | - Manfred Gruener
- Department of Oral Technology, Faculty of Medicine, University of Bonn, 53111 Bonn, Germany
| | - Christoph Bourauel
- Department of Oral Technology, Faculty of Medicine, University of Bonn, 53111 Bonn, Germany
| |
Collapse
|
5
|
Kasuga Y, Kimura S, Maki K, Unno H, Omori S, Hirano K, Ebihara A, Okiji T. Phase transformation and mechanical properties of heat-treated nickel-titanium rotary endodontic instruments at room and body temperatures. BMC Oral Health 2023; 23:825. [PMID: 37904159 PMCID: PMC10614384 DOI: 10.1186/s12903-023-03550-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 10/18/2023] [Indexed: 11/01/2023] Open
Abstract
BACKGROUND The aim of this study was to evaluate the phase composition, phase transformation temperatures, bending property, and cyclic fatigue resistance of different heat-treated nickel-titanium (NiTi) rotary instruments with the same tip diameter and taper at room (RT; 25 ± 1 °C) and body (BT; 37 ± 1 °C) temperatures. METHODS Five heat-treated NiTi rotary instruments, HyFlex EDM (EDM), HyFlex CM (CM), Vortex Blue (VB), RE file CT (RE) and JIZAI, and a non-heat-treated NiTi rotary instrument (Mtwo) with a size 40, 0.04 taper were investigated. Temperature-dependent phase transformation was examined with differential scanning calorimetry (DSC). The bending loads of the instruments at RT and BT were evaluated using a cantilever-bending test. Cyclic fatigue resistance at RT and BT was measured using a dynamic test, during which the instruments were rotated in combination with a 2-mm back-and-forth motion in an artificial curved canal, and the number of cycles to failure (NCF) was determined. The results were analyzed using two-way repeated measures analysis of variance, a simple main effect test, and the Bonferroni test (α = 0.05). RESULTS DSC results indicated that EDM and Mtwo were primarily composed of martensite/R-phase and austenite, respectively, while the other heat-treated instruments were composed of a mix of martensite/R-phase and austenite at the tested temperatures. Regardless of the temperature setting, the bending loads of heat-treated instruments were significantly lower than those of Mtwo (p < 0.05). EDM showed the lowest bending loads and highest NCF at both temperatures (p < 0.05). CM, VB, and JIZAI showed significantly higher bending loads at BT than at RT (p < 0.05). The NCF of all the heat-treated instruments, except VB, was lower at BT than at RT (p < 0.05). At BT, the NCF of CM, VB, RE, and JIZAI were not significantly higher than that of Mtwo (p > 0.05). CONCLUSIONS Heat-treated NiTi instruments exhibited lower bending loads and higher NCF values than Mtwo. However, this tendency was less pronounced at BT than at RT, especially in the NCF values of instruments with a mixture of martensite/R-phase and austenite phases at the tested temperatures.
Collapse
Affiliation(s)
- Yuka Kasuga
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Shunsuke Kimura
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan.
| | - Keiichiro Maki
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Hayate Unno
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Satoshi Omori
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Keiko Hirano
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Arata Ebihara
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Takashi Okiji
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| |
Collapse
|
6
|
Grande NM, Castagnola R, Minciacchi I, Marigo L, Plotino G. A review of the latest developments in rotary NiTi technology and root canal preparation. Aust Dent J 2023; 68 Suppl 1:S24-S38. [PMID: 37960998 DOI: 10.1111/adj.12998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2023] [Indexed: 11/15/2023]
Abstract
The introduction of nickel-titanium (NiTi) mechanical instruments dramatically changed clinical endodontics over the last few decades. Before NiTi, it was necessary to use more instruments to create an ideal root canal shape, and many approaches, sequences and techniques were developed over the years. Recently, NiTi endodontic instruments have undergone a series of changes brought about by modifications in design, surface treatments, and thermal treatments to improve their root canal preparation outcomes and reduce associated canal preparation risks during root canal treatment. Heat treatment is one of the most fundamental approaches to improving the fatigue resistance and flexibility of NiTi endodontic instruments. In addition, new kinematics have been developed to offer greater safety and efficiency. This narrative review describes the general properties and manufacturing of NiTi instruments, and the mechanical system evolution of NiTi instruments.
Collapse
Affiliation(s)
- N M Grande
- Dipartimento di Testa-Collo e organi di senso, Università Cattolica del Sacro Cuore, Rome, Italy
| | - R Castagnola
- Dipartimento di Testa-Collo e organi di senso, Università Cattolica del Sacro Cuore, Rome, Italy
| | | | - L Marigo
- Dipartimento di Testa-Collo e organi di senso, Università Cattolica del Sacro Cuore, Rome, Italy
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo. Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | | |
Collapse
|
7
|
Suresh B, Jeevanandan G, Ravindran V, Mashyakhy M, Alessa N, Syed AA, Panda S, Assiry AA, Maganur PC, Vishwanathaiah S. Comparative Evaluation of Extrusion of Apical Debris in Primary Maxillary Anterior Teeth Using Two Different Rotary Systems and Hand Files: An In Vitro Study. CHILDREN (BASEL, SWITZERLAND) 2023; 10:children10050898. [PMID: 37238446 DOI: 10.3390/children10050898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 05/10/2023] [Accepted: 05/15/2023] [Indexed: 05/28/2023]
Abstract
Successful outcome of pulp therapy depends on good chemomechanical preparation of the canals. This is completed with the help of various upcoming rotary and hand files. However, during this preparation, there might be an apical extrusion of the debris which may result in postoperative complications. The aim of this study was to evaluate and compare the number of debris apically extruded during canal preparation using two different pediatric rotary file systems and conventional hand file systems in primary teeth. 60 primary maxillary central incisors that were extracted due to trauma or untreated dental caries with no signs of resorption were taken. Canal preparation was executed using three different file systems: Group A: Group A hand K file system, Group B Kedo S Plus, Group C Kedo SG Blue. For each of these files using the Myers and Montgomery model, the pre- and post-weight of the eppendorf tube was assessed to quantify the number of apical debris. The maximum extrusion of apical debris was noticed with the Hand K-file system. The least debris was noticed in the Kedo S Plus file system. Statistical analysis revealed that there were highly significant differences in apical extrusion and debris when comparing hand files and rotary files and also between the two rotary files used. Apical debris collection is an unavoidable outcome of canal instrumentation. Among the file systems compared, rotary files had lesser extrusion when compared to hand files. Among the rotary files, Kedo S plus showed normal extrusion compared to SG Blue.
Collapse
Affiliation(s)
- Balaji Suresh
- Department of Pediatric and Preventive Dentistry, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai 600077, India
| | - Ganesh Jeevanandan
- Department of Pediatric and Preventive Dentistry, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai 600077, India
| | - Vignesh Ravindran
- Department of Pediatric and Preventive Dentistry, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai 600077, India
| | - Mohammed Mashyakhy
- Restorative Dental Science Department, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
| | - Noura Alessa
- Department of Pediatric Dentistry and Orthodontics, Dental College, King Saud University, Riyadh 11545, Saudi Arabia
| | - Ather Ahmed Syed
- Department of Preventive Dental Sciences, Division of Pediatric Dentistry, College of Dentistry, Jazan University, Jazan 45152, Saudi Arabia
| | - Suman Panda
- Department of Preventive Dental Sciences, Division of Pediatric Dentistry, College of Dentistry, Jazan University, Jazan 45152, Saudi Arabia
| | - Ali Ahmed Assiry
- Preventive Dental Science Department, Faculty of Dentistry, Najran University, Najran 1988, Saudi Arabia
| | - Prabhadevi C Maganur
- Department of Preventive Dental Sciences, Division of Pediatric Dentistry, College of Dentistry, Jazan University, Jazan 45152, Saudi Arabia
| | - Satish Vishwanathaiah
- Department of Preventive Dental Sciences, Division of Pediatric Dentistry, College of Dentistry, Jazan University, Jazan 45152, Saudi Arabia
| |
Collapse
|
8
|
Almohareb RA, Barakat RM, Algahtani FN, Alkadi MF. Cyclic fatigue resistance of EdgeTaper Platinum, Protaper Gold, and TruNatomy Prime rotary files before and after autoclave sterilization. PeerJ 2023; 11:e14656. [PMID: 36700004 PMCID: PMC9869776 DOI: 10.7717/peerj.14656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 12/07/2022] [Indexed: 01/22/2023] Open
Abstract
Background This in vitro investigation aimed to determine the influence of multiple autoclave cycles on the cyclic fatigue resistance of three heat-treated nickel-titanium (NiTi) files: EdgeTaper Platinum (ETP), ProTaper Gold (PTG), and TruNatomy Prime (TN). Materials Sixty NiTi files, twenty of each NiTi file type: ETP 25/.06, PTG 25/.08, and TN 26/.04 were randomly divided into four equal subgroups (n = 5). The files for the control group were left un-autoclaved. Different autoclave sterilization cycles (one, five, and ten) were used for the other three groups. The files were then placed in a metal canal block and rotated according to the manufacturer's instructions until fracture. The length of the broken segment and the time taken for fracture were measured. The fractured surfaces were subsequently subjected to SEM imaging. The Kruskal-Wallis test was used to analyze the data, followed by Dunn-Bonferroni pairwise comparisons. Statistical significance was set at p < 0.05. Results ETP showed significantly greater resistance to cyclic fatigue than TN in all autoclave groups and PTG after five autoclave cycles (p = 0.014). Fatigue resistance was not affected by the number of autoclaving cycles, except for ETP. After the first and tenth autoclaving cycles, they required significantly more rotations to failure than the non-sterilized files (p = 0.039 and p = 0.021, respectively). The fractured segments of the ETP files in these two groups were also longer than those in the control group (p = 0.010). Conclusion The cyclic fatigue resistance of ETP was greater than that of TN in all tested conditions. Repeated autoclave cycles of sterilization improved the cyclic fatigue resistance of the ETP files only and did not affect the cyclic fatigue resistance of TN and PTG. However, the ETP files separated at a longer distance from the tip with increased autoclaving cycles.
Collapse
Affiliation(s)
- Rahaf A. Almohareb
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Reem M. Barakat
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Fahda N. Algahtani
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Manal F. Alkadi
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| |
Collapse
|
9
|
Roshdy NN, Hassan R. Quantitative evaluation of apically extruded debris using TRUShape, TruNatomy, and WaveOne Gold in curved canals. BDJ Open 2022; 8:13. [PMID: 35595771 PMCID: PMC9122899 DOI: 10.1038/s41405-022-00106-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 02/19/2022] [Accepted: 02/21/2022] [Indexed: 11/09/2022] Open
Abstract
Abstract
Objective
This study compared the quantity of extruded debris after instrumentation with TRUShape 3D Conforming files, TruNatomy files, and the WaveOne Gold reciprocating system.
Materials and methods
Fifty-one mesiobuccal canals with severe curvatures (25–40°) were assigned to three equal groups according to the rotary system used for preparation, either TRUShape, TruNatomy, or WaveOne Gold files. The extruded debris was collected in pre-weighed glass vials. The data were statistically analyzed using a one-way ANOVA test and Tukey’s post hoc test.
Results
The least extruded debris was obtained with the WaveOne Gold instruments compared to the TRUShape and TruNatomy files (p < 0.001).
Conclusions
Debris extrusion occurs independently of the motion or design of the instrument. The WaveOne Gold system outperformed TRUShape and TruNatomy files in this study.
Collapse
|
10
|
Uygun AD. Comparison of apical debris extrusion of different generation nickel-titanium instrument systems. Niger J Clin Pract 2022; 25:2010-2015. [PMID: 36537459 DOI: 10.4103/njcp.njcp_455_22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
BACKGROUND AND AIM The aim of this study is to evaluate the apical debris extrusion amounts and preparation times of four different nickel-titanium systems with a similar cross-section design-Mtwo, RECIPROC, RECIPROC blue, and VDW.ROTATE. MATERIALS AND METHODS Eighty human mandibular central incisors were divided into four equal groups (n = 20). The test apparatus was inserted into an assembly that provided root canal temperature. Preparation times were recorded using a stopwatch, and the amount of extruded debris was collected in pre-weighed Eppendorf tubes. After drying, the net amount was determined by subtracting the previously measured Eppendorf tube weights from the total weight. RESULTS The Mtwo had the largest amount of debris, but there was no significant difference among the other groups. The VDW.ROTATE completed the preparation in a significantly shorter time than the RECIPROC blue and Mtwo. CONCLUSION Compared to other files, the Mtwo sequence produced significantly more debris and required significantly more time to complete the whole root canal preparation.
Collapse
Affiliation(s)
- A D Uygun
- Department of Endodontics, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey
| |
Collapse
|
11
|
Berutti E, Moccia E, Lavino S, Multari S, Carpegna G, Scotti N, Pasqualini D, Alovisi M. Micro-Computed Tomography Evaluation of Minimally Invasive Shaping Systems in Mandibular First Molars. J Clin Med 2022; 11:jcm11154607. [PMID: 35956222 PMCID: PMC9370045 DOI: 10.3390/jcm11154607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Revised: 08/03/2022] [Accepted: 08/04/2022] [Indexed: 11/24/2022] Open
Abstract
The aim of this study was to compare the shaping ability of a modified ProTaper Next technique (PTNm) with that of TruNatomy (TN) in lower molars mesial curved canals using micro-computed tomography (Micro-CT). Sixty mesial canals of first mandibular molars were randomly assigned between two groups (n = 30). After canal scouting with K-File #10, glide path and shaping were carried out with TN or PTNm systems. The PTNm sequence consists of ProGlider, followed by ProTaper Next X1 and apical finishing with NiTiFlex #25 up to working length (WL) to ensure adequate apical cleaning. Samples were scanned using micro-CT and pre- and post-shaping volumes were matched to analyse geometric parameters: the volume of removed dentin; the difference of canal surface; centroid shift, minimum and maximum root canal diameters; cross-sectional areas; the ratio of diameter ratios (RDR) and the ratio of cross-sectional areas (RA). Measurements were assessed 2 mm from the apex and in relation to the middle and coronal root canal thirds. Data were analysed using ANOVA (p < 0.05). No statistically significant differences were found between the groups for any parameter at each level of analysis, except for RA at the coronal level (p = 0.037). The PTNm system showed the tendency to enlarge more in the coronal portion with a lower centroid shift at apical level compared with TN sequence (p > 0.05). Both PTNm and TN sequences demonstrated similar maintenance of original anatomy during the shaping of lower molar mesial curved canals.
Collapse
|
12
|
Guillory M, Vall P. Past, Present, and Future Trends of Nickel Titanium Rotary Instrumentation. J Vet Dent 2022; 39:257-268. [PMID: 35585702 DOI: 10.1177/08987564221098566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This article reviews the historical development, properties, and trends of nickel titanium rotary instrumentation use for the veterinary endodontist.
Collapse
Affiliation(s)
| | - Patrick Vall
- Animal Dental Care and Oral Surgery, Colorado Springs, CO
| |
Collapse
|
13
|
Chen C, Zhang W, Liang Y. Evaluation of apical root defects during canal instrumentation with two different nickel-titanium (NiTi) systems by optical coherence tomography (OCT) scan. J Dent Sci 2022; 17:763-770. [PMID: 35756775 PMCID: PMC9201542 DOI: 10.1016/j.jds.2021.10.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 10/02/2021] [Indexed: 01/20/2023] Open
|
14
|
Impact of Radial Lands on the Reduction of Torque/Force Generation of a Heat-Treated Nickel-Titanium Rotary Instrument. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12052620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
This study investigated the impact of a one-sided radial-landed cross-sectional design of a heat-treated nickel-titanium rotary instrument (JIZAI, MANI, Japan; JZ) on torque/force generation and canal-shaping ability, using an experimental non-landed instrument (non-landed JZ) for comparison. Both instruments had tip sizes of 25 and 0.04 or 0.06 taper and were similar in metallurgy and geometry, except for the presence/absence of a radial land. Twenty J-shaped simulated resin canals were instrumented in a two-instrument single-length sequence using an automated root canal instrumentation device with a torque/force analyzing unit. Pre- and post-instrumentation images of the resin canals were analyzed for canal-centering ability at 0–3 mm from the apex. The mean centering ratio was not significantly different between JZ and non-landed JZ (p > 0.05). In the 2nd instrumentation, JZ showed a significantly smaller torque compared with the non-landed JZ (p < 0.05). Regardless of instrumentation sequence, JZ showed a significantly smaller maximum upward force, representing screw-in force (p < 0.05), and a larger maximum downward force (p < 0.05) than the non-landed JZ. JZ generated smaller screw-in forces and had similar canal-centering ability compared with the non-landed JZ.
Collapse
|
15
|
Evolution and development: engine-driven endodontic rotary nickel-titanium instruments. Int J Oral Sci 2022; 14:12. [PMID: 35181648 PMCID: PMC8857196 DOI: 10.1038/s41368-021-00154-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 12/06/2021] [Accepted: 12/20/2021] [Indexed: 11/08/2022] Open
Abstract
Various engine-driven NiTi endodontic files have been indispensable and efficient tools in cleaning and shaping of root canals for practitioners. In this review, we introduce the relative terms and conceptions of NiTi file, including crystal phase composition, the design of the cutting part, types of separation. This review also analysis the main improvement and evolution of different generations of engine-driven nickel-titanium instruments in the past 20 years in the geometric design, manufacturing surface treatment such as electropolishing, thermal treatment, metallurgy. And the variety of motion modes of NiTi files to improve resistance to torsional failure were also discussed. Continuous advancements by the designers, provide better balance between shaping efficiency and resistance to of NiTi systems. In clinical practice an appropriate system should be selected based on the anatomy of the root canal, instrument characteristics, and operators' experience.
Collapse
|
16
|
Arias A, Peters OA. Present Status and Future Directions - Canal Shaping. Int Endod J 2022; 55 Suppl 3:637-655. [PMID: 35118683 PMCID: PMC9303733 DOI: 10.1111/iej.13698] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/30/2022] [Accepted: 02/01/2022] [Indexed: 12/01/2022]
Abstract
This narrative review will focus on the evolution, present and future of engine‐driven root canal preparation. Root canal preparation changed drastically when Walia in 1988 introduced the use of nickel‐titanium (NiTi) alloys in Endodontics. In 2013, five generations of NiTi endodontic instruments had been established based on their metallurgical, mechanical properties and design features. Since then, manufacturers have been introducing further major changes in instrument design and characteristics that have not been translated in new recognized generations of instruments. In general, those changes have demonstrated enhanced instrument properties, but it is not clear yet if all those improvements are directly translated to an improvement in clinical success. This narrative review attempts to address the present status of engine‐driven instruments in terms of both evidence from laboratory‐based studies and clinical data, to identify potential further generations of instruments, and last to anticipate future directions for research and development.
Collapse
Affiliation(s)
- A Arias
- School of Dentistry, Complutense University, Madrid, Spain
| | - O A Peters
- School of Dentistry, The University of Queensland, Herston, QLD, Australia
| |
Collapse
|
17
|
Saber SM, Alfadag AMA, Nawar NN, Plotino G, Hassanien EES. Instrumentation Kinematics Does Not Affect Bacterial Reduction, Post-Operative Pain and flare-ups: A Randomized Clinical Trial. Int Endod J 2022; 55:405-415. [PMID: 35100456 DOI: 10.1111/iej.13695] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 01/26/2022] [Accepted: 01/27/2022] [Indexed: 11/25/2022]
Abstract
AIM This randomized clinical trial aimed to assess the effect of instrumentation kinematics (reciprocation or continuous rotation) on bacterial reduction, post-operative pain and incidence of flare-ups after root canal treatment of single-rooted mandibular premolars with asymptomatic apical periodontitis. METHODOLOGY Sixty-six patients were included in this prospective, parallel, randomized clinical trial. Patients were randomly allocated into two groups (N=33) according to the kinematics of the shaping instrument: WaveOne Gold (WO) used in reciprocation or One Shape (OS) used in continuous rotation. Under complete asepsis, bacterial samples were taken before (S1) and after (S2) a standard cleaning and shaping protocol. Evaluation of bacterial reduction was done by both culture technique and quantitative real-time polymerase chain reaction (qPCR) analysis. Post-operative pain was evaluated using the visual analog scale (VAS) after 24, 48- and 72-hours following treatment, while flare-ups were recorded as a binary outcome (Yes/No). Independent and paired t-tests were used for inter and intragroup comparisons for bacterial count data respectively. For post-operative pain score, intergroup comparisons were analyzed using Mann-Whitney U test while intragroup comparisons were analyzed using Friedman test followed by pairwise comparisons utilizing Wilcoxon signed rank test with Bonferroni correction. The significance level was set at p≤0.05 within all tests. RESULTS All the allocated participants received the intervention and were analyzed. The comparison between culture and qPCR methods showed that qPCR analysis demonstrated significantly higher pre-instrumentation baseline bacterial count (p<0.05). The percentage of bacterial reduction, detected by either method, significantly decreased after instrumentation using either rotation or reciprocation kinematics (p<0.05). However, the difference between the WOG or OS files was statistically non-significant (p>0.05). The intra-group comparisons showed a significant reduction in post-operative pain with time (p<0.05) for both groups. However, the inter-group comparison demonstrated that the difference in post-operative pain after the use of either WOG or OS was statistically non-significant (p>0.05). The incidence of flare-ups between both groups was also not-significant (p=1). CONCLUSIONS Shaping kinematics, either rotation or reciprocation motions, had no impact on bacterial reduction and the incidence of post-operative pain and flare-ups after root canal preparation of single-rooted premolars with asymptomatic apical periodontitis.
Collapse
Affiliation(s)
- Shehabeldin Mohamed Saber
- Department of Endodontics, Ain Shams University, Cairo, Egypt.,Department of Endodontics, The British University, El-Shorouk city, Egypt
| | | | - Nawar Naguib Nawar
- Department of Endodontics, The British University, El-Shorouk city, Egypt
| | | | - Ehab El-Sayed Hassanien
- Department of Endodontics, Ain Shams University, Cairo, Egypt.,El-Galala University, El-Galala city, Egypt
| |
Collapse
|
18
|
Antony D, Subramanian A, Nivedhitha M, Solete P, Balasubramaniam A. Post-endodontic pain with different engine-driven endodontic instruments in multi-visit root canal therapy: A systematic review and meta-analysis. J Int Oral Health 2022. [DOI: 10.4103/jioh.jioh_127_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
19
|
|
20
|
Schäfer E, Bürklein S, Donnermeyer D. A critical analysis of research methods and experimental models to study the physical properties of NiTi instruments and their fracture characteristics. Int Endod J 2021; 55 Suppl 1:72-94. [PMID: 34862796 DOI: 10.1111/iej.13673] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Accepted: 12/03/2021] [Indexed: 11/27/2022]
Abstract
The aim of this review is to provide a critical overview of the physical properties (surface hardness, cutting efficiency, bending properties, flexibility and cyclic fatigue resistance) of NiTi instruments. Frequently used experimental models regarding these aspects will be presented and discussed with regard to their strengths and weaknesses. For all these aspects, a plethora of experimental models have been described. Based on a critical appraisal and especially taking the appropriate translation of experimental findings to clinical endodontics into account, suggestions for future research based on clearly defined and valid experimental methodologies will be provided. Up to now, very few attempts have been made to assess which particular physical properties of NiTi instruments exert an impact on the clinical outcome of root canal treatment. Departure from merely focusing on physical properties and fracture characteristics towards more biological aspects in terms of treatment outcome is essential.
Collapse
Affiliation(s)
- Edgar Schäfer
- Central Interdisciplinary Ambulance in the School of Dentistry, Münster, Germany
| | - Sebastian Bürklein
- Central Interdisciplinary Ambulance in the School of Dentistry, Münster, Germany
| | - David Donnermeyer
- Department of Periodontology and Operative Dentistry, Westphalian Wilhelms-University, Münster, Germany
| |
Collapse
|
21
|
The Influence of Root Canal Preparation with ProTaper Next, WaveOne Gold, and Twisted Files on Dentine Crack Formation. MACHINES 2021. [DOI: 10.3390/machines9120332] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
(1) Background: Root canal preparation constitutes an important factor for success in endodontics. However, various complications may occur during this stage. The aim of this study was to compare the incidence of cracks within radicular dentin after instrumentation with ProTaper Next (PTN), WaveOne Gold (WOG), and Twisted Files (TF), which utilize different kinematics. (2) Methods: Eighty single-rooted teeth were classified into four groups (n = 20). Three groups were instrumented using PTN (X1, X2), WOG (Primary), and TF (SM1–3). The non-instrumented group constituted the control group. Post-preparation, the roots were sectioned 3, 6, and 9 mm from the apex using a low-speed saw (Southbay Technology Inc., San Clemente, CA, USA). The specimens were viewed through a microscope at x25 magnification (Leica M320, Wetzlar, Germany), and their surface was assessed tactilely to determine the presence of the crack. (3) Results: Partial cracks within radicular dentine were observed in all study groups (PTN: n = 4/20%, WOG: n = 3/15%, TF: n = 4/20%); no cracks were observed in the control group. No significant differences were observed among experimental groups. OR values for the incidence of cracks were: OR = 11.182 for PTN, OR = 8.2 for WOG, and OR = 8.2 for TF. (4) Conclusions: Instrumentation with PTN, WOG, and TF may result in dentinal cracks formation.
Collapse
|
22
|
Kwak SW, Shen Y, Liu H, Wang Z, Kim HC, Haapasalo M. Heat Treatment and Surface Treatment of Nickel–Titanium Endodontic Instruments. FRONTIERS IN DENTAL MEDICINE 2021. [DOI: 10.3389/fdmed.2021.769977] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Knowledge and thorough understanding of the characteristics of endodontic nickel–titanium (NiTi) files is paramount for dentists performing root canal treatments to patients. Understanding the behavior of the NiTi files guides the clinicians in choosing the correct instruments for different clinical and anatomical situations. This review focuses on the metallurgical properties of endodontic NiTi files, with a special emphasis on recent developments and improvements in metallurgy and the effects of heat treatment and surface treatment. In this study, the impact that such developments have on the properties of endodontic NiTi files is discussed.
Collapse
|
23
|
Yon MJY, Tang MHY, Cheung GSP. Defects and Safety of NiTi Root Canal Instruments: A Systematic Review and Meta-Analysis. FRONTIERS IN DENTAL MEDICINE 2021. [DOI: 10.3389/fdmed.2021.747071] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Aim: To review the reported defect and fracture rates of various NiTi instrumentation systems and identify factors that may influence the chance of NiTi file separation clinically.Data Sources: PubMed, EMBASE, and SCOPUS with controlled vocabulary and keywords in various combinations to identify articles that reported on the defects and/or fracture of NiTi instrument used clinically (Jan 1980 till Aug 2021), with additional search manually by going through the list of references of the initially screened articles. Those satisfying the inclusion and exclusion criteria were entered into the analysis.Study Eligibility Criteria, Participants, and Interventions: All studies from the said databases reporting on NiTi root canal instruments that were deformed or separated during normal clinical use.Study Appraisal and Synthesis Methods: Studies with data available and suitable for meta-analysis were grouped according to the general design of the NiTi instruments for comparison. Safety quotient value was calculated based on the rate of instrument distortion and fracture.Results: Various instrument designs exhibited different incidences of distortion and fracture, hence a different “safety quotient” (ratio of the amount of deformed instruments to that of fractures in use). Heat-treated files showed the highest safety quotient value. All brands of NiTi file demonstrated a statistically significantly lower incidence of fracture, if treated as disposable instruments after clinical use in a patient.Limitations: Inclusion of articles written in English only, and grouping of file systems into general design types in the analysis.Conclusions and Implications of Key Findings: NiTi endodontic files should be scrutinized for defects before being used in the root canal. Disposing the NiTi instruments after clinical use in a patient (so-called “single use”) is recommended for minimizing fracture clinically. Certain instrument designs tend to show discernible deformation before they should fracture in the next use.
Collapse
|
24
|
Alovisi M, Pasqualini D, Scotti N, Carpegna G, Comba A, Bernardi M, Tutino F, Dioguardi M, Berutti E. Micro-CT evaluation of rotary and reciprocating glide path and shaping systems outcomes in maxillary molar curved canals. Odontology 2021; 110:54-61. [PMID: 34173078 PMCID: PMC8732797 DOI: 10.1007/s10266-021-00631-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Accepted: 06/17/2021] [Indexed: 12/03/2022]
Abstract
The shaping outcomes after instrumentation with rotary and reciprocating glide path and shaping systems were evaluated through micro-computed tomography (Micro-CT). Thirty extracted maxillary first molars were selected. Mesio-buccal canals were randomized into two groups (n = 15): rotary system ProGlider and ProTaper Next X1, X2 (PG-PTN) and reciprocating system WaveOne Gold Glider and WaveOne Gold Primary (WOGG-WOG). Specimens were micro-CT scanned before, after glide path and after shaping. Increase in canal volume and surface area, percentage of removed dentin from the inner curvature, centroid shift and canal geometry variation through ratio of diameter ratios (RDR) and ratio of cross-sectional areas (RA) were measured in the apical and coronal levels and at the point of maximum curvature. The number of pecking motions needed to reach the working length (WL) was recorded. One-way ANOVA and post hoc Turkey–Kramer tests were used (p < 0.05). Post-glide path analysis revealed that in the coronal third, RDR was more favorable to PG and centroid shift was lower for WOGG in the apical third. Post-shaping analysis showed a reduced removal of dentin and a more favorable RA for PTN at point of maximum curvature. The number of pecking motions up to WL resulted in different between groups both for glide path and shaping phases. Despite a higher dentin removal for reciprocating instruments at the point of maximum curvature, both systems seemed to produce well-centered glide path and shaping outcomes. Rotary and reciprocating systems seemed able to respect the original canal anatomy.
Collapse
Affiliation(s)
- Mario Alovisi
- Department of Surgical Sciences, Dental School, University of Turin, via Nizza, 230, 10126, Turin, Italy.
| | - Damiano Pasqualini
- Department of Surgical Sciences, Dental School, University of Turin, via Nizza, 230, 10126, Turin, Italy
| | - Nicola Scotti
- Department of Surgical Sciences, Dental School, University of Turin, via Nizza, 230, 10126, Turin, Italy
| | - Giorgia Carpegna
- Department of Surgical Sciences, Dental School, University of Turin, via Nizza, 230, 10126, Turin, Italy
| | - Allegra Comba
- Department of Surgical Sciences, Dental School, University of Turin, via Nizza, 230, 10126, Turin, Italy
| | - Mattia Bernardi
- Department of Surgical Sciences, Dental School, University of Turin, via Nizza, 230, 10126, Turin, Italy
| | - Fabio Tutino
- Department of Surgical Sciences, Dental School, University of Turin, via Nizza, 230, 10126, Turin, Italy
| | - Mario Dioguardi
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| | - Elio Berutti
- Department of Surgical Sciences, Dental School, University of Turin, via Nizza, 230, 10126, Turin, Italy
| |
Collapse
|
25
|
Gomaa MA, Osama M, Badr AE. Shaping ability of three thermally treated nickel-titanium systems in S-shaped canals. AUST ENDOD J 2021; 47:435-441. [PMID: 33660339 DOI: 10.1111/aej.12496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 01/17/2021] [Accepted: 02/16/2021] [Indexed: 11/29/2022]
Abstract
This study aimed to compare the shaping ability of ProTaper Next (PTN), HyFlex EDM (HEDM) and One Curve (OC) systems manufactured via different thermal treatment methods in simulated S-shaped canals. Sixty S-shaped canals in clear resin blocks were enlarged to a final apical size of 25 using PTN, HEDM and OC instruments (n = 20 canals/group). Composite images were obtained by superimposing pre- and post-preparation images. The amount of removed resin was measured perpendicularly to the canal surface in 22 points. Prepared canal width and canal transportation at different levels were determined. Canal aberrations were also recorded. Data were statistically analysed using analysis of variance, the Kruskal-Wallis and the chi-square tests at a 0.05 significance level. OC produced the most conservative enlargement and better maintained particularly the apical curvature of the S-shaped canals than HEDM and PTN. OC and HEDM better maintained the canal terminus and coronal curvature than PTN.
Collapse
Affiliation(s)
- Mohamed A Gomaa
- Department of Endodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Mohammad Osama
- Department of Endodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Amany E Badr
- Department of Endodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
26
|
Yalniz H, Koohnavard M, Oncu A, Celikten B, Orhan AI, Orhan K. Comparative evaluation of dentin volume removal and centralization of the root canal after shaping with the ProTaper Universal, ProTaper Gold, and One-Curve instruments using micro-CT. J Dent Res Dent Clin Dent Prospects 2021; 15:47-52. [PMID: 33927841 PMCID: PMC8058162 DOI: 10.34172/joddd.2021.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 11/29/2020] [Indexed: 11/19/2022] Open
Abstract
Background. The main goal of our study was to assess the volume of dentin removed and transportation in root canals using ProTaper Universal (PTU), ProTaper Gold (PTG) and One-Curve (OC). Ni-Ti rotary instruments in extracted human teeth using by micro-CT. Methods: Thirty human upper 1st premolar teeth with two separate root canals and sturdy, mature root tips were used in the present study. Specimens were decoronated and root length was standardized for micro CT scanning before root canal preparation done. The teeth were randomly separated into three categories (n = 10) according to the rotary NiTi system used for canal instrumentation, i.e., PTU (Dentsply, Maillefer), PTG (Dentsply, Maillefer), and OC (Micro-Mega SA). After root canal preparation, samples were scanned again on micro-CT by the same scanning parameters. Surface area, canal volume, structure model index (SMI), percentage of uninstrumented area and transportation parameters were obtained for each sample before and after micro-CT analyse. Results: No significant differences between the PTG and PTU in terms of the total volume of removed dentin, surface area and percentage of uninstrumented areas were found. However, regarding to parameters above, OC showed a lower efficacy than PTG and PTU in coronal section. Regarding canal transportation, PTG and OC showed lower mean transportation values at all levels. Conclusion: This paper demonstrated the root canal shaping abilities of the PTU, PTG, and OC NiTi file systems. The PTG and OC systems were associated less canal transportation and a better ability to preserve dentinal walls than PTU. There was no significance different between all rotary file systems for SMI values however, PTU and PTG showed greater canal volume and surface area change than OC file systems in coronal section.
Collapse
Affiliation(s)
- Hatice Yalniz
- Bezmialem Vakif University, Faculty of Dentistry, Department of Endodontics, Istanbul, Turkey
| | - Mehrdad Koohnavard
- Ankara University, Faculty of Dentistry, Department of Endodontics, Ankara, Turkey
| | - Aysenur Oncu
- Ankara University, Faculty of Dentistry, Department of Endodontics, Ankara, Turkey
| | - Berkan Celikten
- Ankara University, Faculty of Dentistry, Department of Endodontics, Ankara, Turkey
| | - Ayse Isil Orhan
- Ankara Yildirim Beyazit University, Department of Pediatric Dentistry, Ankara, Turkey
| | - Kaan Orhan
- Ankara University, Faculty of Dentistry, Department of DentoMaxillofacial Radiology, Ankara, Turkey
| |
Collapse
|
27
|
Hou XM, Yang YJ, Qian J. Phase transformation behaviors and mechanical properties of NiTi endodontic files after gold heat treatment and blue heat treatment. J Oral Sci 2020; 63:8-13. [PMID: 33281148 DOI: 10.2334/josnusd.19-0331] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
WaveOne Gold, ProTaper Gold, Reciproc Blue, ProTaper Next, WaveOne and ProTaper files were selected to compare the phase transformation behaviors and mechanical properties of nickel-titanium (NiTi) rotary files after gold heat and blue heat treatments. The reverse transformation finishing point temperatures of WaveOne Gold, ProTaper Gold, ProTaper Next and WaveOne were higher than those of the other two instruments investigated. At a deflection of 0.5 mm, the loads were significantly varied except for ProTaper Next and ProTaper Gold. At a deflection of 3.0 mm, the loads of Reciproc Blue and WaveOne Gold were significantly varied compared to WaveOne and ProTaper. Cycles to failure were reduced in the order of WaveOne Gold, Reciproc Blue, ProTaper Gold, ProTaper Next, WaveOne and ProTaper. NiTi instruments after gold heat and blue heat treatments exhibited significantly higher bending properties and cyclic fatigue resistances, representing an improved performance over traditional and M-wire instruments.
Collapse
Affiliation(s)
- Xiao-Mei Hou
- The Second Dental Center of Peking University School of Stomatology
| | - Yin-Jie Yang
- Department of Stomatology, Beijing Xicheng District Xinjiekou Community Health Service Center
| | - Jun Qian
- The Second Dental Center of Peking University School of Stomatology
| |
Collapse
|
28
|
The Influence of Brushing Movement on Geometrical Shaping Outcomes: A Micro-CT Study. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10144805] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Brushing motion has been proposed for endodontic single-file reciprocating systems to eliminate coronal interferences, but it may hesitate in a less conservative root canal shaping. The aim of the study was to compare the maintenance of the original root canal anatomy using the WaveOne Gold (WOG) technique with or without a brushing motion. Sixty extracted human mandibular first molars were selected. Manual canal scouting and mechanical glide path were performed. Samples were randomized into two groups (n = 30): WOG Primary was used to shape the mesio-lingual canals without (NB group) or with (B group) an intentional brushing motion. Specimens were scanned with micro-computed tomography (micro-CT) before and after instrumentation in order to match the volumes. Increases in canal volume and surface area were measured. Centroid shift and thickness of removed dentine from the inner curvature were assessed at the furcation, 1.5 mm and 3 mm apically from the furcation, and in relation to the point of maximum curvature. Data were analyzed by one-way ANOVA and post-hoc Student–Newmann–Keuls tests (p < 0.05). No brushing technique resulted in being significantly associated with a better maintenance of the canal anatomy, especially in the coronal third (p < 0.05). When using the WOG system, a no-brushing technique resulted in less invasive shaping, reducing the risk of stripping.
Collapse
|
29
|
Eymirli A, Uzunoğlu Özyürek E, Serper A. Sealer penetration: effect of separated file's cross-section, taper and motion characteristics. Clin Oral Investig 2020; 25:1077-1084. [PMID: 32562075 DOI: 10.1007/s00784-020-03404-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2019] [Accepted: 06/10/2020] [Indexed: 01/16/2023]
Abstract
OBJECTIVES The separated root canal instruments may affect the quality of root canal filling, hence the success of endodontic treatment. The aim of this study was to evaluate the effects of separated file fragments of nickel-titanium rotary systems with different cross-section, taper and motion characteristics on the apical sealer penetration in oval-shaped root canals via confocal laser scanning microscope (CLSM). MATERIALS AND METHODS Distal roots of 60 mandibular molars with oval-shaped root canals were randomly divided into 4 groups as follows: group 1, FlexMaster Nickel Titanium Rotary File System (NTRFS) (separated instrument: 30/.06); group 2, ProTaper Next NTRFS (X3); group 3, ProTaper Universal NTRFS (F3); group 4, Revo-S NTRFS (AS30/.06). Root canals were filled with gutta-percha and AH plus labelled with 0.1% rhodamine B using a warm vertical compaction technique. Each specimen was horizontally sectioned at 1st, 3rd and 5th mm from apical foramen. Amount of maximum and average penetration depths, penetration percentage and sealer penetrated area were measured and analysed with one-way repeated measures of ANOVA and the Bonferroni post hoc tests. p < 0.05 was considered significant. RESULTS The penetration depth, percentage and penetrated area of the sealer increased from apical to coronal in all systems. The maximum and average penetration depths and penetration areas were higher in FlexMaster and Revo-S groups at the 3rd mm (p < 0.05). At the 5th mm, the Revo-S group had a higher penetration percentage, when compared with ProTaper Next and ProTaper Universal groups (p < 0.05). CONCLUSIONS In the 1st mm, separated fragments of any system did not allow the penetration of the sealer, while it was observed that the files with constant taper showed more positive results in terms of sealer penetration at apical 3rd and 5th mm. CLINICAL RELEVANCE In the presence of a separated file, the taper of the file might significantly affect the amount of penetrated sealer into the dentinal tubules as compared with the cross-section and motion characteristics of the file.
Collapse
Affiliation(s)
- Ayhan Eymirli
- Department of Endodontics, Faculty of Dentistry, Hacettepe University, Sihhiye, 06100, Ankara, Turkey
| | - Emel Uzunoğlu Özyürek
- Department of Endodontics, Faculty of Dentistry, Hacettepe University, Sihhiye, 06100, Ankara, Turkey.
| | - Ahmet Serper
- Department of Endodontics, Faculty of Dentistry, Hacettepe University, Sihhiye, 06100, Ankara, Turkey
| |
Collapse
|
30
|
Razcha C, Zacharopoulos A, Anestis D, Mikrogeorgis G, Zacharakis G, Lyroudia K. Micro-Computed Tomographic Evaluation of Canal Transportation and Centering Ability of 4 Heat-Treated Nickel-Titanium Systems. J Endod 2020; 46:675-681. [DOI: 10.1016/j.joen.2020.01.020] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2019] [Revised: 01/16/2020] [Accepted: 01/28/2020] [Indexed: 11/15/2022]
|
31
|
Evaluation of Pressure Distribution against Root Canal Walls of NiTi Rotary Instruments by Finite Element Analysis. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10082981] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The aim of this study was to evaluate the contact pressure distribution of two different nickel-titanium (NiTi) endodontic rotary instruments against the root canal walls and to virtually predict their centering ability during shaping with finite element analysis (FEA). Resin blocks simulating root canals were used. One was shaped with ProGlider and ProTaper Next (PTN) X1-X2 and one with ScoutRace and BioRace (BR) 1, 2 and 3. Both resin blocks were virtually replicated with computer-aided design (CAD) software. The endodontic instruments ProTaper Next (PTN) X2 and BioRace BR3 were also replicated with CAD. The NiTi instruments and the shaped blocks geometries were discretized and exported for FEA. The instrument rotation in the root canals was simulated. The finite element simulation was performed by applying an insertion and extraction force of 2.5 N with a constant rotational speed (300 rpm). To highlight possible differences between pressure distributions against the root canal portions outside and inside the canal curvature, the parameter Var was originally defined. Var values were systematically lower for PTN X2, revealing a better centering ability. FEA proved effective for the virtual prediction of the centering ability of NiTi instruments during an early design phase without the use of prototypes.
Collapse
|
32
|
Alfadley A. Comparison of cyclic fatigue resistance of three NiTi glide path files with different cross-sectional geometric characteristics: An in vitro experimental study. J Int Oral Health 2020. [DOI: 10.4103/jioh.jioh_191_19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
33
|
Çelik G, Özdemir Kısacık F, Yılmaz EF, Mersinlioğlu A, Ertuğrul İF, Orhan H. A comparative study of root canal shaping using protaper universal and protaper next rotary files in preclinical dental education. PeerJ 2019; 7:e7419. [PMID: 31489262 PMCID: PMC6705381 DOI: 10.7717/peerj.7419] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Accepted: 07/05/2019] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND Dentistry has undergone an evolution in endodontics practice caused by the advancement of rotary techniques for root canal preparation and their subsequent incorporation into the teaching of dentistry undergraduates. This research aimed to evaluate the shaping ability of third-year dental students as their first experience in rotary instrumentation using ProTaper Universal (PTU) and ProTaper Next (PTN) (Dentsply Maillefer) rotary instruments in simulated curved canals. METHODS Forty students instrumented 200 simulated canals with a 40° curvature in resin blocks according to the manufacturer's instructions with PTU and 39 students and 195 canals with PTN files. The canals were prepared at a speed of 300 rpm using a 16:1 reduction hand-piece powered by an electric motor (Xsmart; Dentsply Maillefer). The final apical preparation was set to F2 for the PTU and X2 for the PTN group. The change in canal curvature was evaluated based on Schneider technique using the AutoCAD 2007 software on post-digital photographs. The incidence of instrument fracture and deformation, the incidence of ledge, the change in working length (WL), and the working time were noted. The data were analyzed with Student's t-test and Chi-Square test at a significance level of 0.05 using SPSS. RESULTS PTN maintained the original canal curvature better, resulting in fewer fractures and ledges, and shaped the canals faster than the PTU (P < 0.05). The mean curves of the resin canals after the instrumentation for the PTU and PTN groups were 24.03° ± 3.14° and 25.64° ± 2.72°, respectively. Thirty-three (17.4%) PTU and 18 (9.3%) PTN files fractured (p < 0.05). Nine (4.5%) PTU and 2 (2.6%) PTN deformed (p > 0.05). The change in WL after instrumentation was 0.97 mm ± 0.95 mm in PTU and 0.96 mm ± 0.80 mm in PTN (p < 0.05). The mean times were 627 s ± 18 s for PTU and 379 s ± 18 s for PTN (p < 0.000). DISCUSSION PTN can be recommended in severely curved root canals in terms of maintenance of the original canal curvature, superior instrument fracture and fewer ledges. Even if training before preparation provides an acceptable level of canal shaping for preclinical students, the use of NiTi rotary instruments should be included in the undergraduate dental curriculum, contributing to an increase in the quality of root canal shaping and, consequently, to an improvement of the clinical experience of students.
Collapse
Affiliation(s)
- Gül Çelik
- Faculty of Dentistry, Endodontics, Suleyman Demirel University, Isparta, Turkey
| | | | | | | | - İhsan Furkan Ertuğrul
- Faculty of Dentistry, Departmant of Endodontics, Pamukkale University, Denizli, Turkey
| | - Hikmet Orhan
- Faculty of Medicine, Biostatistics and Medical Informatics, Suleyman Demirel University, Isparta, Turkey
| |
Collapse
|
34
|
Hülsmann M, Donnermeyer D, Schäfer E. A critical appraisal of studies on cyclic fatigue resistance of engine-driven endodontic instruments. Int Endod J 2019; 52:1427-1445. [PMID: 31267579 DOI: 10.1111/iej.13182] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Accepted: 06/30/2019] [Indexed: 11/29/2022]
Abstract
The endodontic literature contains a plethora of studies on static and dynamic cyclic fatigue resistance tests performed on a large array of rotary or reciprocating nickel-titanium endodontic instruments. It was the aim of this review to summarize the currently available evidence to point out the different outcomes from static versus dynamic tests and to assess whether cyclic fatigue tests provide useful data and information for clinical practice. An electronic literature research in the database PubMed was performed using appropriate search terms, and the titles and abstract were screened for relevance. Language was restricted to English. The review reveals marked differences between the results obtained in static and dynamic tests, and also, the results for the same instruments assessed either under static or dynamic experimental conditions are widely inconsistent. Between the lowest and the highest value for one and the same pathfinding instrument was a factor of about 123 when cyclic fatigue was assessed either under static or dynamic experimental conditions. Moreover, standard deviations of up to 30% have been reported. Environmental temperature has a 500% impact on the lifetime of instruments. In conclusion, fatigue resistance tests conducted under room temperature should be regarded as having little meaning and the scientific and clinical benefits of fatigue resistance tests are very limited. These data should be provided by the manufacturer of the instruments.
Collapse
Affiliation(s)
- M Hülsmann
- Department of Preventive Dentistry, Periodontology and Cariology, University Medicine Göttingen (UMG), Göttingen, Germany
| | - D Donnermeyer
- Department of Periodontology and Operative, Westphalian Wilhelms-University, Münster, Germany
| | - E Schäfer
- Central Interdisciplinary Ambulance, Westphalian Wilhelms-University, Münster, Germany
| |
Collapse
|
35
|
Keskin NB, Inan U. Cyclic fatigue resistance of rotary NiTi instruments produced with four different manufacturing methods. Microsc Res Tech 2019; 82:1642-1648. [PMID: 31254483 DOI: 10.1002/jemt.23330] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 05/20/2019] [Accepted: 06/13/2019] [Indexed: 11/09/2022]
Abstract
The aim of this study was to compare the cyclic fatigue resistance of rotary NiTi files, produced with four different manufacturing methods on specially designed dynamic models that simulated clinical conditions. In this study, 120 files, consisting of 30 files for Typhoon, ProTaper Next, RaCe, and Twisted Files nickel titanium rotary systems were used. The 30 files of each group were divided into three subgroups to be used in artificial canals with a 60° angle of curvature and radii of curvature of 2, 5, and 8 mm (n = 10). All files were rotated in the artificial canals until fracture occurred and the number of cycles to fracture was calculated. The data were analyzed using one- and two-way analyses of variance and Tamhane multiple comparison tests. In all three groups, Typhoon instruments had the highest number of cycles to failure than the RaCe, ProTaper Next, and Twisted Files instruments, and the difference statistically significant (p < .05). There were no significant differences between the RaCe, ProTaper Next, and Twisted Files groups (p > .05). The CM wire Typhoon system was significantly more resistant to cyclic fatigue compared to the other file systems in all three artificial canals. When the fracture resistance of an instrument in three different artificial canals was compared, the mean NCFs decreased as the radius of the curvature of the canal decreased from 8 to 2 mm. Manufacturing method is one of the most important factors on cyclic fatigue resistance, also the radius of curvature effects the cyclic fatigue.
Collapse
Affiliation(s)
- Neslihan B Keskin
- Department of Endodontics, Faculty of Dentistry, Yıldırım Beyazıt University, Ankara, Turkey
| | - Uğur Inan
- Department of Endodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey
| |
Collapse
|
36
|
Nayak A, Kankar PK, Jain PK, Jain N. Force and vibration generated in apical direction by three endodontic files of different kinematics during simulated canal preparation: An in vitro analytical study. Proc Inst Mech Eng H 2019; 233:839-848. [PMID: 31165678 DOI: 10.1177/0954411919854574] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
During root canal shaping, pain could result from the high level of force or vibration generated. This could be related to file kinematics or geometry. In the present study, a comparison is made between forces and vibrations generated by endodontic files having three different kinematics. Square pillar resin blocks were used as simulated root canals to study forces and vibrations generated by the file having reciprocating motion (WaveOne Gold), transline motion (Self-Adjusting File), and rotary motion (2Shape). The forces and vibrations were measured using the dynamometer and accelerometer, respectively. Recorded time domain signals were processed in MATLAB to calculate the root mean square value. A one-way analysis of variance and Tukey's test for post hoc comparison at 95% confidence interval were applied over the root mean square data of different files. From a statistical analysis of the file systems, the null hypotheses could not be accepted (P < 0.05) as 95% of the confidence interval. Differences between the means were statistically significant. The root mean square values of force and vibration for WaveOne Gold significantly exceeded those of Self-Adjusting File, 2Shape1, and 2Shape2 while the root mean square values of vibration for 2Shape1 and 2Shape2 were significantly less than the Self-Adjusting File; however, the root mean square value of force for the 2Shape2 was significantly more than for the Self-Adjusting File. Under the present experimental conditions, significant differences in the root mean square values of force and vibration of the three endodontic files of different kinematics have been observed. The WaveOne Gold file system generated higher apical force and vibration than the transline and rotary file system.
Collapse
Affiliation(s)
| | - P K Kankar
- 2 Indian Institute of Technology Indore, Indore, India
| | | | - Niharika Jain
- 3 Department of Conservative Dentistry & Endodontics, Triveni Institute of Dental Science, Hospital & Research Centre, Bilaspur, India
| |
Collapse
|
37
|
de Cristofaro Almeida G, Aun DP, Resende PD, Peixoto IFDC, Viana ACD, Buono VTL, de Azevedo Bahia MG. Comparative analysis of torque and apical force to assess the cutting behaviour of ProTaper Next and ProTaper Universal endodontic instruments. AUST ENDOD J 2019; 46:52-59. [PMID: 31087492 DOI: 10.1111/aej.12351] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/25/2019] [Indexed: 11/28/2022]
Abstract
This study assessed the cutting properties of two Nickel Titanium file systems with different designs and manufacturing materials. ProTaper Next X1 and X2 (PTN; Dentsply Sirona) and ProTaper Universal S2 and F1 (PTU; Dentsply Sirona) instruments were employed. The cutting parameters, that is torque and apical forces, were determined using a specially designed bench-testing machine. Dimensional and geometric parameters were considered to evaluate the results. The average maximum torque values showed statistically significant differences (P < 0.05) among all instruments. Apical force for PTN X2 and PTU F1 instruments initially decreased and then experienced a rapid increase in the last 2 mm of the canal. For PTN X1 and PTU S2, apical force increased during the entire test. When compared to PTU files, PTN required higher torque and apical forces during the shaping procedure. The results lead us to conclude that PTN instruments demonstrated a lower cutting efficiency than PTU.
Collapse
Affiliation(s)
- Gustavo de Cristofaro Almeida
- Department of Restorative Dentistry, Faculty of Dentistry, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, Brazil
| | - Diego Pinheiro Aun
- Department of Metallurgical and Materials Engineering, School of Engineering, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, Brazil
| | - Pedro Damas Resende
- Department of Metallurgical and Materials Engineering, School of Engineering, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, Brazil
| | - Isabella Faria da Cunha Peixoto
- Department of Restorative Dentistry, Faculty of Dentistry, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, Brazil
| | - Ana Cecília Diniz Viana
- Department of Restorative Dentistry, Faculty of Dentistry, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, Brazil
| | - Vicente Tadeu Lopes Buono
- Department of Metallurgical and Materials Engineering, School of Engineering, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, Brazil
| | - Maria Guiomar de Azevedo Bahia
- Department of Restorative Dentistry, Faculty of Dentistry, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, Brazil
| |
Collapse
|
38
|
Herbst SR, Krois J, Schwendicke F. Comparator Choice in Studies Testing Endodontic Instrument Fatigue Resistance: A Network Analysis. J Endod 2019; 45:784-790. [PMID: 30952371 DOI: 10.1016/j.joen.2019.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2018] [Revised: 01/20/2019] [Accepted: 02/08/2019] [Indexed: 10/27/2022]
Abstract
AIMS Endodontic instruments are frequently compared against each other for their cyclic fatigue resistance (CFR). It is unclear what drives the comparator choice in CFR studies, and how comparators and comparisons have evolved over time. We aimed at evaluating CFR study networks, hypothesizing that indications and instrument properties (alloy, manufacturer) drive comparisons. METHODS A systematic review was performed via Medline and Embase (1986-2017). In vitro studies analyzing the CFR of ≥2 engine-driven instruments in an artificial curved root canal system were included. We classified instruments according to name, alloy, and manufacturer. Study networks were analyzed using social network analysis techniques. RESULTS Eighty-five studies on 56 different instruments (9 alloys, 17 manufacturers) were included. For instruments, a low-density (0.19), highly clustered (0.71) network with 3 separate subnetworks (for glide path, shaping, and retreatment instruments) emerged. Certain instruments (ProTaper Universal [Dentsply Maillefer, Ballaigues, Switzerland], Mtwo [VDW Dental, Munich, Germany]) served as hub nodes and possible gold standards. Conventional Nickel-Titanium was the most frequently used alloy. Few manufacturers dominated the network. The diversity of tested instruments, alloys, and manufacturers increased in recent years. CONCLUSIONS Comparisons of CFR were usually made along indications. Some instruments and alloys (conventional Nickel-Titanium) dominated the networks. Overall risk of bias by comparator choice seems moderate; however, the evidence on certain, less often tested instruments may not be robust. Factors underlying the network geometry (eg, sponsorship) should be explored.
Collapse
Affiliation(s)
- Sascha Rudolf Herbst
- Department of Operative and Preventive Dentistry, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany
| | - Joachim Krois
- Department of Operative and Preventive Dentistry, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany
| | - Falk Schwendicke
- Department of Operative and Preventive Dentistry, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany.
| |
Collapse
|
39
|
Campos CN, Campos AO, Bellei MC. Tecnologia a serviço da Endodontia: avanços no diagnóstico e tratamento de canais radiculares. HU REVISTA 2019. [DOI: 10.34019/1982-8047.2018.v44.13928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
A Endodontia é a especialidade da Odontologia que cuida da prevenção, diagnóstico e tratamento das afecções que acometem a polpa dental, a cavidade endodôntica e os tecidos periodontais adjacentes. O tratamento endodôntico, considerado complexo e desgastante para o paciente e operador, durante anos vem sendo foco de atenção para estudiosos da área e indústria especializada. O objetivo deste estudo de revisão de literatura foi apresentar, de forma sucinta, a evolução tecnológica dedicada à endodontia nas últimas décadas e suas consequências na atualidade. Muitos foram os estudos que acarretaram no desenvolvimento de aparelhos, instrumentos, materiais e técnicas hoje utilizadas visando a simplificação, agilização e aumento da taxa de sucesso do tratamento endodôntico. Entre os principais incrementos na endodontia podemos citar os modernos instrumentos endodônticos, os sofisticados motores e aparelhos controlados eletronicamente e alguns materiais. Esses, modificaram significativamente a forma de realizar algumas etapas do tratamento como a odontometria, o preparo químico-mecânico, a obturação, o reparo de perfurações e, ainda, o diagnóstico por imagem, tornando a endodontia mais segura, eficiente, rápida, com maior previsibilidade e menos cansativa para profissional e paciente.
Collapse
|
40
|
Drukteinis S, Peciuliene V, Dummer PMH, Hupp J. Shaping ability of BioRace, ProTaper NEXT and Genius nickel-titanium instruments in curved canals of mandibular molars: a MicroCT study. Int Endod J 2018; 52:86-93. [PMID: 29858500 DOI: 10.1111/iej.12961] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2017] [Accepted: 05/30/2018] [Indexed: 01/13/2023]
Abstract
AIM To evaluate and compare the canal shaping ability of BioRace, ProTaper NEXT and Genius engine-driven nickel-titanium (NiTi) file systems in extracted mandibular first molars using micro-computed tomography (MCT). METHODOLOGY Sixty mesial root canals of mandibular first molars were randomly divided into three equal groups, according to the instrument system used for root canal preparation (n = 20): BioRace (BR), ProTaper NEXT (PTN) or Genius (GN). Root canals were prepared to the full WL using a crown-down technique up to size 35, .04 taper instruments for BR and GN groups and size 30, .07 taper instruments for the PTN group. MCT was used to scan the specimens before and after canal instrumentation. Changes in dentine volume, the percentage of uninstrumented canal surface and degree of canal transportation were evaluated in the coronal, middle and apical thirds of canals. Data were analysed statistically using one-way analysis of variance and Tuckey's post hoc tests with the significance level set at 5%. RESULTS There were no significant differences between the three groups in the terms of dentine removed after preparation and determination of the root canal volume, or percentage of uninstrumented canal surface (P > 0.05). No significant differences were found between the systems for canal transportation in any canal third (P > 0.05). CONCLUSIONS The shaping ability of the BR, PTN and GN NiTi file systems was equally effective. All instrumentation systems prepared curved root canal systems with no evidence of undesirable changes in 3D parameters or significant shaping errors.
Collapse
Affiliation(s)
- S Drukteinis
- Institute of Dentistry, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
| | - V Peciuliene
- Institute of Dentistry, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
| | - P M H Dummer
- School of Dentistry, College of Biomedical and Life Sciences, Cardiff University, Cardiff, UK
| | - J Hupp
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT, USA
| |
Collapse
|
41
|
Kyaw Moe MM, Ha JH, Jin MU, Kim YK, Kim SK. Root Canal Shaping Effect of Instruments with Offset Mass of Rotation in the Mandibular First Molar: A Micro–computed Tomographic Study. J Endod 2018; 44:822-827. [DOI: 10.1016/j.joen.2017.11.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 11/08/2017] [Accepted: 11/15/2017] [Indexed: 10/18/2022]
|
42
|
Shen Y, Huang X, Wang Z, Wei X, Haapasalo M. Low Environmental Temperature Influences the Fatigue Resistance of Nickel-titanium Files. J Endod 2018; 44:626-629. [DOI: 10.1016/j.joen.2017.11.004] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2017] [Revised: 10/28/2017] [Accepted: 11/06/2017] [Indexed: 11/24/2022]
|
43
|
Influence of Contracted Endodontic Access on Root Canal Geometry: An In Vitro Study. J Endod 2018; 44:614-620. [DOI: 10.1016/j.joen.2017.11.010] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2017] [Revised: 10/15/2017] [Accepted: 11/15/2017] [Indexed: 11/23/2022]
|
44
|
Sekiya M, Maeda M, Katsuumi I, Igarashi M. Evaluation of four instruments with different working motion using artificial plastic model with C-shaped single canal. Odontology 2018; 106:422-428. [PMID: 29429057 PMCID: PMC6153976 DOI: 10.1007/s10266-018-0348-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Accepted: 01/01/2018] [Indexed: 11/18/2022]
Abstract
The purpose of this study was to evaluate four instruments with different working motion for preparation of a C-shaped single canal wall using the same artificial plastic models reproduced from a human tooth. One tooth with root canal morphology C1 (the shape is an uninterrupted “C” with no separation or division) was selected among three-dimensional micro-computed tomography (micro-CT) imaging data of extracted human teeth. Imaging data were then converted into STL form data, and twenty-four C-shaped root canal model blocks were manufactured using this STL form data. These blocks were randomly divided into four groups of six blocks each and instrumented as follows: stainless steel K-files (SSK), Self-Adjusting File (SAF), ProTaper NEXT (PTN) and RECIPROC (REC). Micro-CT images taken before and after canal preparation were superimposed, and instrumented canal area, percentage of instrumented canal area, part of instrumented canal area, volume of instrumented canal and time taken for instrumentation were evaluated for each group. The greatest instrumented canal area, percentage of instrumented canal area and volume of instrumented canal were as follows (in decreasing order): SSK > SAF > PTN > REC (P < 0.05). The longest time taken for instrumentation was as follows (in decreasing order): SAF > SSK > PTN > REC (P < 0.05). The conscious shaping of SSK and the lattice structure of SAF were instrumented all root canal walls equally. PTN and REC required less time taken for instrumentation, but showed unequal instrumentation.
Collapse
Affiliation(s)
- Miki Sekiya
- Department of Endodontics, The Nippon Dental University School of Life Dentistry at Tokyo, 1-9-20 Fujimi, Chiyoda-ku, Tokyo, 102-8159, Japan.
| | - Munehiro Maeda
- Department of Endodontics, The Nippon Dental University School of Life Dentistry at Tokyo, 1-9-20 Fujimi, Chiyoda-ku, Tokyo, 102-8159, Japan
| | - Ichiroh Katsuumi
- Department of Endodontics, The Nippon Dental University School of Life Dentistry at Tokyo, 1-9-20 Fujimi, Chiyoda-ku, Tokyo, 102-8159, Japan
| | - Masaru Igarashi
- Department of Endodontics, The Nippon Dental University School of Life Dentistry at Tokyo, 1-9-20 Fujimi, Chiyoda-ku, Tokyo, 102-8159, Japan
| |
Collapse
|
45
|
Özyürek T, Gündoğar M, Uslu G, Yılmaz K, Staffoli S, Nm G, Plotino G, Polimeni A. Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals. Odontology 2018; 106:408-413. [PMID: 29383604 DOI: 10.1007/s10266-018-0340-y] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Accepted: 01/11/2018] [Indexed: 11/30/2022]
Abstract
The aim of the present study was to compare the cyclic fatigue resistances of HyFlex EDM (HEDM), WaveOne Gold (WOG), Reciproc Blue (RB), and 2Shape (TS) NiTi systems having different metallurgic properties. HEDM, WOG, RB, and TS instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 45°, and 90° angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture (TTF) was recorded in seconds. Also, number of cycles to fracture was calculated (NCF). Data were statistically analyzed using Kruskal-Wallis and t test. The statistical significance level was set at P < 0.05. When comparing the TTF of all the instruments tested in the artificial canal with 45° curvature, RB had statistically the highest cyclic fatigue resistance followed by HEDM and TS (P < 0.05), while the WOG showed the lowest cyclic fatigue resistance (P < 0.05). In artificial canal with 90° curvature, RB showed a significantly higher cyclic fatigue resistance than the other tested files (P < 0.05), while there was no significant difference among the TS, WOG and HEDM groups (P > 0.05). When the NCF values were taken into consideration, HEDM reported a significantly higher cyclic fatigue resistance than TS in both canal curvatures analyzed (P < 0.05). Within the limitations of the present study, RB NiTi files showed statistically higher cyclic fatigue resistance in artificial canals with 45° and 90° than the other NiTi files tested.
Collapse
Affiliation(s)
- Taha Özyürek
- Department of Endodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey.
| | - Mustafa Gündoğar
- Department of Endodontics, Faculty of Dentistry, Medipol University, İstanbul, Turkey
| | - Gülşah Uslu
- Private Practice, Dental Clinic, Çanakkale, Turkey
| | - Koray Yılmaz
- Çorum Oral and Dental Health Centre, Çorum, Turkey
| | - Simone Staffoli
- Department of Oral and Maxillo-Facial Science, "Sapienza"-University of Rome, Rome, Italy
| | - Grande Nm
- Department of Endodontics, Catholic University of Sacred Heart, Rome, Italy
| | | | - Antonella Polimeni
- Department of Oral and Maxillo-Facial Science, "Sapienza"-University of Rome, Rome, Italy
| |
Collapse
|
46
|
Irmak Ö, Orhan EO. Kinematic analysis of new and used reciprocating endodontic motors in 2 different modes. Int J Artif Organs 2017; 41:0. [PMID: 28862719 DOI: 10.5301/ijao.5000640] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/20/2017] [Indexed: 11/20/2022]
Abstract
PURPOSE The actual reciprocating angles of endodontic motors might differ from the manufacturers' set values. This study analyzed the effect of clinical usage on the kinematics of reciprocating endodontic motors with 2 different reciprocal modes. METHODS 1 new and 3 used reciprocating endodontic motors (X-Smart Plus, Dentsply Maillefer) with 2 different reciprocating modes, WaveOne mode (W-mode) or Reciproc mode (R-mode), were analyzed. An angle measurement disc was inserted into a contra-angle. Reciprocating motions were recorded with a high-speed camera at 1,200 fps and analyzed on a computer. The following kinematic parameters were calculated: duration of each reciprocating motion, engaging and disengaging angles, cycle rotational speeds, engaging and disengaging rotational speeds, net cycle angle, total cycle angle, and number of cycles to complete full rotation. One-way ANOVA and Kruskal-Wallis test followed by multiple comparison tests were used for statistical analysis (p = 0.05). RESULTS In W-mode, the actual engaging angles of all used and new motors were different from the manufacturer's set values (p<0.0001), whereas there was no difference between actual engaging angles among the motors (p>0.05). In R-mode, the actual engaging angles of all used and new motors were similar to the manufacturers' set values (p>0.05). There was no difference between the actual engaging angles among motors (p>0.05). Both the W-mode and R-mode showed statistically different values of actual disengaging angles for all used and new motors when compared with the manufacturers' set value (p<0.0001). CONCLUSIONS This study confirmed that the actual kinematics of reciprocating endodontic motors differ from the manufacturers' set values. Some kinematic parameters were influenced by the clinical usage of the motors.
Collapse
Affiliation(s)
- Özgür Irmak
- Department of Restorative Dentistry, Faculty of Dentistry, Eskişehir Osmangazi University, Eskişehir - Turkey
| | - Ekim O Orhan
- Department of Endodontics, Faculty of Dentistry, Eskişehir Osmangazi University, Eskişehir - Turkey
| |
Collapse
|
47
|
Choi DM, Kim JW, Park SH, Cho KM, Kwak SW, Kim HC. Vibrations Generated by Several Nickel-titanium Endodontic File Systems during Canal Shaping in an Ex Vivo Model. J Endod 2017; 43:1197-1200. [PMID: 28454634 DOI: 10.1016/j.joen.2017.03.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Revised: 02/25/2017] [Accepted: 03/06/2017] [Indexed: 11/28/2022]
Abstract
INTRODUCTION This study aimed to compare the vibration generated by several nickel-titanium (NiTi) file systems and transmitted to teeth under 2 different motions (continuous rotation motion and reciprocating motion). METHODS Sixty J-shaped resin blocks (Endo Training Bloc-J; Dentsply Maillefer, Ballaigues, Switzerland) were trimmed to a root-shaped form and divided into 2 groups according to the types of electric motors: WaveOne motor (WOM, Dentsply Maillefer) and X-Smart Plus motor (XSM, Dentsply Maillefer). Each group was further subdivided into 3 subgroups (n = 10 each) according to the designated file systems: ProTaper Next (PTN, Dentsply Maillefer), ProTaper Universal (PTU, Dentsply Maillefer), and WaveOne (WOP, Dentsply Maillefer) systems. Vibration was measured during the pecking motion using an accelerometer attached to a predetermined consistent position. The average vibration values were subjected to 2-way analysis of variance as well as the t test and Duncan test for post hoc comparison at the 95% confidence interval. RESULTS Both motor types and instrument types produced significantly different ranges of average vibrations. Regardless of the instrument types, the WOM group generated greater vibration than the XSM group (P < .05). Although PTN and PTU did not show significant differences, the WOP group showed significantly greater vibration than the other groups regardless of motor types (P < .05). CONCLUSIONS Under the limitations of this study design, the reciprocating NiTi file system may generate greater vibration than the continuous rotation NiTi file systems. The motor type also has a significant effect to amplify the vibrations.
Collapse
Affiliation(s)
- Dong-Min Choi
- Department of Conservative Dentistry, School of Dentistry, Gangeung-Wonju National University, Gangneung, Korea
| | - Jin-Woo Kim
- Department of Conservative Dentistry, School of Dentistry, Gangeung-Wonju National University, Gangneung, Korea
| | - Se-Hee Park
- Department of Conservative Dentistry, School of Dentistry, Gangeung-Wonju National University, Gangneung, Korea
| | - Kyung-Mo Cho
- Department of Conservative Dentistry, School of Dentistry, Gangeung-Wonju National University, Gangneung, Korea
| | - Sang Won Kwak
- Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Pusan National University, Yangsan, Korea
| | - Hyeon-Cheol Kim
- Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Pusan National University, Yangsan, Korea.
| |
Collapse
|
48
|
Bürklein S, Jäger PG, Schäfer E. Apical transportation and canal straightening with different continuously tapered rotary file systems in severely curved root canals: F6 SkyTaper and OneShape versus Mtwo. Int Endod J 2016; 50:983-990. [DOI: 10.1111/iej.12716] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Accepted: 10/28/2016] [Indexed: 11/25/2022]
Affiliation(s)
- S. Bürklein
- Central Interdisciplinary Ambulance in the School of Dentistry; University of Münster; Münster Germany
| | - P. G. Jäger
- Central Interdisciplinary Ambulance in the School of Dentistry; University of Münster; Münster Germany
| | - E. Schäfer
- Central Interdisciplinary Ambulance in the School of Dentistry; University of Münster; Münster Germany
| |
Collapse
|
49
|
Dagna A, Gastaldo G, Beltrami R, Poggio C. Debris Evaluation after Root Canal Shaping with Rotating and Reciprocating Single-File Systems. J Funct Biomater 2016; 7:E28. [PMID: 27763503 PMCID: PMC5197987 DOI: 10.3390/jfb7040028] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Revised: 09/29/2016] [Accepted: 10/11/2016] [Indexed: 11/16/2022] Open
Abstract
This study evaluated the root canal dentine surface by scanning electron microscope (SEM) after shaping with two reciprocating single-file NiTi systems and two rotating single-file NiTi systems, in order to verify the presence/absence of the smear layer and the presence/absence of open tubules along the walls of each sample; Forty-eight single-rooted teeth were divided into four groups and shaped with OneShape (OS), F6 SkyTaper (F6), WaveOne (WO) and Reciproc and irrigated using 5.25% NaOCl and 17% EDTA. Root canal walls were analyzed by SEM at a standard magnification of 2500×. The presence/absence of the smear layer and the presence/absence of open tubules at the coronal, middle, and apical third of each canal were estimated using a five-step scale for scores. Numeric data were analyzed using Kruskal-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P < 0.05; The Kruskal-Wallis ANOVA for debris score showed significant differences among the NiTi systems (P < 0.05). The Mann-Whitney test confirmed that reciprocating systems presented significantly higher score values than rotating files. The same results were assessed considering the smear layer scores. ANOVA confirmed that the apical third of the canal maintained a higher quantity of debris and smear layer after preparation of all the samples; Single-use NiTi systems used in continuous rotation appeared to be more effective than reciprocating instruments in leaving clean walls. The reciprocating systems produced more debris and smear layer than rotating instruments.
Collapse
Affiliation(s)
- Alberto Dagna
- Department of Clinical Surgical Diagnostic and Pediatric Sciences, Section of Dentistry, University of Pavia, Piazzale Golgi 3, Pavia 27100, Italy.
| | - Giulia Gastaldo
- Department of Clinical Surgical Diagnostic and Pediatric Sciences, Section of Dentistry, University of Pavia, Piazzale Golgi 3, Pavia 27100, Italy.
| | - Riccardo Beltrami
- Department of Brain and Behavioral Sciences, University of Pavia, Piazzale Golgi 3, Pavia 27100, Italy.
| | - Claudio Poggio
- Department of Clinical Surgical Diagnostic and Pediatric Sciences, Section of Dentistry, University of Pavia, Piazzale Golgi 3, Pavia 27100, Italy.
| |
Collapse
|
50
|
Silva EJNL, Pacheco PT, Pires F, Belladonna FG, De-Deus G. Microcomputed tomographic evaluation of canal transportation and centring ability of ProTaper Next and Twisted File Adaptive systems. Int Endod J 2016; 50:694-699. [DOI: 10.1111/iej.12667] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2016] [Accepted: 06/01/2016] [Indexed: 12/01/2022]
Affiliation(s)
- E. J. N. L. Silva
- Department of Endodontics; School of Dentistry; Grande Rio University (UNIGRANRIO); Duque de Caxias RJ Brazil
| | - P. T. Pacheco
- Department of Endodontics; School of Dentistry; Grande Rio University (UNIGRANRIO); Duque de Caxias RJ Brazil
| | - F. Pires
- Department of Endodontics; School of Dentistry; Grande Rio University (UNIGRANRIO); Duque de Caxias RJ Brazil
| | - F. G. Belladonna
- Department of Endodontics; Fluminense Federal University (UFF); Niterói RJ Brazil
| | - G. De-Deus
- Department of Endodontics; School of Dentistry; Grande Rio University (UNIGRANRIO); Duque de Caxias RJ Brazil
| |
Collapse
|