Mansell SK, Devani N, Shah A, Schievano S, Main E, Mandal S. Current treatment strategies in managing side effects associated with domiciliary positive airway pressure (PAP) therapy for patients with sleep disordered breathing: A systematic review and meta-analysis. Sleep Med Rev 2023; 72:101850. [PMID: 37812972 DOI: 10.1016/j.smrv.2023.101850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 08/25/2023] [Accepted: 09/12/2023] [Indexed: 10/11/2023]
Abstract
Sleep disordered breathing is commonly treated with positive airway pressure therapy. Positive airway pressure therapy is delivered via a tight-fitting mask with common side effects including: leak, ineffective treatment, residual sleep disordered breathing, eye irritation, nasal congestion, pressure ulcers and poor concordance with therapy. This systematic review and meta-analysis aimed to identify the effectiveness of current treatment strategies for managing side effects associated with positive airway pressure therapy. Five databases were searched and 10,809 articles were screened, with 36 articles included in the review. Studies investigated: dressings, nasal spray/douche, chin straps, heated humidification and interfaces. No intervention either improved or detrimentally affected: positive airway pressure concordance, Epworth Sleepiness Score, residual apnoea hypopnea index or interface leak. The review was limited by study heterogeneity, particularly for outcome measures. Additionally, patient demographics were not reported, making it difficult to apply the findings to a broad clinical population. This review highlights the paucity of evidence supporting treatment strategies to manage side effects of positive airway pressure therapy.
Collapse
Affiliation(s)
| | | | - Amar Shah
- University College London, UK; Royal Free London NHS Foundation Trust, UK
| | | | | | - Swapna Mandal
- University College London, UK; Royal Free London NHS Foundation Trust, UK
| |
Collapse
|
2
|
Deng B, Lai F, Zhang M, Xiong C, Chen F, Zhang H, Ma Y, Zhou D. Nasal pillow vs. standard nasal mask for treatment of OSA: a systematic review and meta-analysis. Sleep Breath 2023; 27:1217-1226. [PMID: 36214944 DOI: 10.1007/s11325-022-02721-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 09/23/2022] [Accepted: 09/30/2022] [Indexed: 11/05/2022]
Abstract
PURPOSE The purpose of this study was to compare the effectiveness of nasal pillows with standard nasal masks in the treatment of patients with obstructive sleep apnea (OSA). METHODS A digitalized search was carried out in four different databases including PubMed, Scopus, EMBASE, and CENTRAL using relevant keywords along with a manual search in relevant journals. All comparative studies comparing outcomes of using a nasal pillow with the use of standard nasal masks for continuous positive airway pressure (CPAP) treatment in patients with OSA were included. The qualitative analysis was carried out by tabulating the demographic data. The quantitative data were subjected to meta-analysis. The quality of comparative studies (both retrospective and prospective cohorts) was evaluated using New-castle Ottawa scale (NOS). RESULTS A total of 14 studies (eight prospective and six retrospective) were included in the review. Of them, five studies were randomized and were of cross-over study design. No significant differences were observed in achieved CPAP and residual apnea-hypopnea index (AHI) levels between the nasal pillow and nasal mask with SMD - 0.05 95% CI [- 0.18, 0.09], p = 0.50 and SMD - 0.13 95% CI [- 0.28, 0.03], p = 0.12, respectively. However, nasal pillow usage was associated with better CPAP adherence with a difference of only + 0.29 min/night as compared to a standard nasal mask, with SMD 0.29 95% CI [0.07, 0.50], p = 0.009. CONCLUSION Nasal pillow and standard nasal mask were equally effective in terms of residual AHI level and achieved similar therapeutic CPAP pressures. However, the difference in CPAP adherence between groups, though statistically significant, is of questionable clinical significance.
Collapse
Affiliation(s)
- Bo Deng
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Fei Lai
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Manman Zhang
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Chenyili Xiong
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Feng Chen
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Heng Zhang
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China.
| | - Yuanyuan Ma
- Department of Orthopedics, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Daiying Zhou
- Department of Orthopedics, Chengdu Longquanyi First People's Hospital, Chengdu, China
| |
Collapse
|
3
|
Chang JL, Goldberg AN, Alt JA, Alzoubaidi M, Ashbrook L, Auckley D, Ayappa I, Bakhtiar H, Barrera JE, Bartley BL, Billings ME, Boon MS, Bosschieter P, Braverman I, Brodie K, Cabrera-Muffly C, Caesar R, Cahali MB, Cai Y, Cao M, Capasso R, Caples SM, Chahine LM, Chang CP, Chang KW, Chaudhary N, Cheong CSJ, Chowdhuri S, Cistulli PA, Claman D, Collen J, Coughlin KC, Creamer J, Davis EM, Dupuy-McCauley KL, Durr ML, Dutt M, Ali ME, Elkassabany NM, Epstein LJ, Fiala JA, Freedman N, Gill K, Boyd Gillespie M, Golisch L, Gooneratne N, Gottlieb DJ, Green KK, Gulati A, Gurubhagavatula I, Hayward N, Hoff PT, Hoffmann OM, Holfinger SJ, Hsia J, Huntley C, Huoh KC, Huyett P, Inala S, Ishman SL, Jella TK, Jobanputra AM, Johnson AP, Junna MR, Kado JT, Kaffenberger TM, Kapur VK, Kezirian EJ, Khan M, Kirsch DB, Kominsky A, Kryger M, Krystal AD, Kushida CA, Kuzniar TJ, Lam DJ, Lettieri CJ, Lim DC, Lin HC, Liu SY, MacKay SG, Magalang UJ, Malhotra A, Mansukhani MP, Maurer JT, May AM, Mitchell RB, Mokhlesi B, Mullins AE, Nada EM, Naik S, Nokes B, Olson MD, Pack AI, Pang EB, Pang KP, Patil SP, Van de Perck E, Piccirillo JF, Pien GW, Piper AJ, Plawecki A, Quigg M, Ravesloot MJ, Redline S, Rotenberg BW, Ryden A, Sarmiento KF, Sbeih F, Schell AE, Schmickl CN, Schotland HM, Schwab RJ, Seo J, Shah N, Shelgikar AV, Shochat I, Soose RJ, Steele TO, Stephens E, Stepnowsky C, Strohl KP, Sutherland K, Suurna MV, Thaler E, Thapa S, Vanderveken OM, de Vries N, Weaver EM, Weir ID, Wolfe LF, Tucker Woodson B, Won CH, Xu J, Yalamanchi P, Yaremchuk K, Yeghiazarians Y, Yu JL, Zeidler M, Rosen IM. International Consensus Statement on Obstructive Sleep Apnea. Int Forum Allergy Rhinol 2023; 13:1061-1482. [PMID: 36068685 PMCID: PMC10359192 DOI: 10.1002/alr.23079] [Citation(s) in RCA: 62] [Impact Index Per Article: 62.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 08/12/2022] [Accepted: 08/18/2022] [Indexed: 11/08/2022]
Abstract
BACKGROUND Evaluation and interpretation of the literature on obstructive sleep apnea (OSA) allows for consolidation and determination of the key factors important for clinical management of the adult OSA patient. Toward this goal, an international collaborative of multidisciplinary experts in sleep apnea evaluation and treatment have produced the International Consensus statement on Obstructive Sleep Apnea (ICS:OSA). METHODS Using previously defined methodology, focal topics in OSA were assigned as literature review (LR), evidence-based review (EBR), or evidence-based review with recommendations (EBR-R) formats. Each topic incorporated the available and relevant evidence which was summarized and graded on study quality. Each topic and section underwent iterative review and the ICS:OSA was created and reviewed by all authors for consensus. RESULTS The ICS:OSA addresses OSA syndrome definitions, pathophysiology, epidemiology, risk factors for disease, screening methods, diagnostic testing types, multiple treatment modalities, and effects of OSA treatment on multiple OSA-associated comorbidities. Specific focus on outcomes with positive airway pressure (PAP) and surgical treatments were evaluated. CONCLUSION This review of the literature consolidates the available knowledge and identifies the limitations of the current evidence on OSA. This effort aims to create a resource for OSA evidence-based practice and identify future research needs. Knowledge gaps and research opportunities include improving the metrics of OSA disease, determining the optimal OSA screening paradigms, developing strategies for PAP adherence and longitudinal care, enhancing selection of PAP alternatives and surgery, understanding health risk outcomes, and translating evidence into individualized approaches to therapy.
Collapse
Affiliation(s)
- Jolie L. Chang
- University of California, San Francisco, California, USA
| | | | | | | | - Liza Ashbrook
- University of California, San Francisco, California, USA
| | | | - Indu Ayappa
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | | | | | | | | | - Maurits S. Boon
- Sidney Kimmel Medical Center at Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Pien Bosschieter
- Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Itzhak Braverman
- Hillel Yaffe Medical Center, Hadera Technion, Faculty of Medicine, Hadera, Israel
| | - Kara Brodie
- University of California, San Francisco, California, USA
| | | | - Ray Caesar
- Stone Oak Orthodontics, San Antonio, Texas, USA
| | | | - Yi Cai
- University of California, San Francisco, California, USA
| | | | | | | | | | | | | | | | | | - Susmita Chowdhuri
- Wayne State University and John D. Dingell VA Medical Center, Detroit, Michigan, USA
| | - Peter A. Cistulli
- Faculty of Medicine and Health, University of Sydney, Sydney, Australia
| | - David Claman
- University of California, San Francisco, California, USA
| | - Jacob Collen
- Uniformed Services University, Bethesda, Maryland, USA
| | | | | | - Eric M. Davis
- University of Virginia, Charlottesville, Virginia, USA
| | | | | | - Mohan Dutt
- University of Michigan, Ann Arbor, Michigan, USA
| | - Mazen El Ali
- University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | | | | | | | | | - Kirat Gill
- Stanford University, Palo Alto, California, USA
| | | | - Lea Golisch
- University Hospital Mannheim, Ruprecht-Karls-University Heidelberg, Heidelberg, Germany
| | | | | | | | - Arushi Gulati
- University of California, San Francisco, California, USA
| | | | | | - Paul T. Hoff
- University of Michigan, Ann Arbor, Michigan, USA
| | - Oliver M.G. Hoffmann
- University Hospital Mannheim, Ruprecht-Karls-University Heidelberg, Heidelberg, Germany
| | | | - Jennifer Hsia
- University of Minnesota, Minneapolis, Minnesota, USA
| | - Colin Huntley
- Sidney Kimmel Medical Center at Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | | | | | - Sanjana Inala
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | | | | | | | | | | | | | | | | | | | - Meena Khan
- Ohio State University, Columbus, Ohio, USA
| | | | - Alan Kominsky
- Cleveland Clinic Head and Neck Institute, Cleveland, Ohio, USA
| | - Meir Kryger
- Yale School of Medicine, New Haven, Connecticut, USA
| | | | | | | | - Derek J. Lam
- Oregon Health and Science University, Portland, Oregon, USA
| | | | | | | | | | | | | | - Atul Malhotra
- University of California, San Diego, California, USA
| | | | - Joachim T. Maurer
- University Hospital Mannheim, Ruprecht-Karls-University Heidelberg, Heidelberg, Germany
| | - Anna M. May
- Case Western Reserve University, Cleveland, Ohio, USA
| | - Ron B. Mitchell
- University of Texas, Southwestern and Children’s Medical Center Dallas, Texas, USA
| | | | | | | | | | - Brandon Nokes
- University of California, San Diego, California, USA
| | | | - Allan I. Pack
- University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | | | | | | | | | | | | | | | - Mark Quigg
- University of Virginia, Charlottesville, Virginia, USA
| | | | - Susan Redline
- Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | | | - Armand Ryden
- Veterans Affairs Greater Los Angeles Healthcare System, Los Angeles, California, USA
| | | | - Firas Sbeih
- Cleveland Clinic Head and Neck Institute, Cleveland, Ohio, USA
| | | | | | | | | | - Jiyeon Seo
- University of California, Los Angeles, California, USA
| | - Neomi Shah
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | | | | | - Ryan J. Soose
- University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | | | - Erika Stephens
- University of California, San Francisco, California, USA
| | | | | | | | | | - Erica Thaler
- University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Sritika Thapa
- Yale School of Medicine, New Haven, Connecticut, USA
| | | | - Nico de Vries
- Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | | | - Ian D. Weir
- Yale School of Medicine, New Haven, Connecticut, USA
| | | | | | | | - Josie Xu
- University of Toronto, Ontario, Canada
| | | | | | | | | | | | - Ilene M. Rosen
- University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
4
|
Chen L, Chen Y, Hu S, Lin M, Lee P, Chiang AA, Tu Y. In search of a better CPAP interface: A network meta-analysis comparing nasal masks, nasal pillows and oronasal masks. J Sleep Res 2022; 31:e13686. [PMID: 35821391 PMCID: PMC9787466 DOI: 10.1111/jsr.13686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Revised: 05/28/2022] [Accepted: 06/17/2022] [Indexed: 12/30/2022]
Abstract
Until now, no study has directly network meta-analysed the impact of nasal masks, nasal pillows and oronasal masks on continuous positive airway pressure therapy in patients with obstructive sleep apnea. This study aimed to meta-analyse the impact of three kinds of nasal interfaces with both network meta-analysis and pairwise comparison. PubMed, EMBASE, CENTRAL and ClinicalTrials.gov were systematically searched from inception to December 2020 for studies that compared the three types of nasal interfaces for treating obstructive sleep apnea with continuous positive airway pressure. The outcomes were residual apnea-hypopnea index, continuous positive airway pressure, and nightly average usage. The network meta-analysis was conducted using multivariate random-effects in a frequentist framework where three interfaces were ranked with the surface under the cumulative ranking probabilities. The pairwise comparison was conducted using random-effects meta-analysis. Twenty-nine articles comprising 6378 participants were included. The pairwise comparison showed both nasal masks and nasal pillows were associated with lower residual apnea-hypopnea index, lower continuous positive airway pressure, and higher continuous positive airway pressure adherence compared with oronasal masks. The surface under the cumulative ranking confirmed that nasal masks were associated with the lowest residual apnea-hypopnea index and highest adherence, while pillows were associated with the lowest continuous positive airway pressure. The meta-regression identified that lower pretreatment apnea-hypopnea index and continuous positive airway pressure determined during continuous positive airway pressure titration (versus determined during continuous positive airway pressure therapy) was associated with lower continuous positive airway pressure with nasal masks and nasal pillows. In conclusion, compared with oronasal masks, nasal masks and nasal pillows are better interfaces, especially in patients with lower pretreatment apnea-hypopnea index and those with the therapeutic pressure determined during continuous positive airway pressure titration.
Collapse
Affiliation(s)
- Li‐Yang Chen
- Department of Internal MedicineTainan Sin Lau HospitalTainanTaiwan
| | - Yung‐Hsuan Chen
- Center of Sleep DisorderNational Taiwan University HospitalTaipeiTaiwan,Department of Internal MedicineNational Taiwan University HospitalTaipeiTaiwan
| | | | - Ming‐Tzer Lin
- Center of Sleep DisorderNational Taiwan University HospitalTaipeiTaiwan,Department of Internal MedicineHsiao Chung‐Cheng HospitalNew TaipeiTaiwan
| | - Pei‐Lin Lee
- Center of Sleep DisorderNational Taiwan University HospitalTaipeiTaiwan,Department of Internal MedicineNational Taiwan University HospitalTaipeiTaiwan,School of MedicineNational Taiwan UniversityTaipeiTaiwan,Center for Electronics Technology Integration, National Taiwan UniversityTaipeiTaiwan
| | - Ambrose A. Chiang
- Division of Sleep Medicine, Louis Stokes VA Medical Center; Department of MedicineCase Western Reserve UniversityClevelandOhioUSA
| | - Yu‐Kang Tu
- Institute of Epidemiology and Preventive Medicine, College of Public Health, National Taiwan UniversityTaipeiTaiwan
| |
Collapse
|
5
|
Frange C, Franco AM, Brasil E, Hirata RP, Lino JA, Mortari DM, Ykeda DS, Leocádio-Miguel MA, D’Aurea CVR, Silva LOE, Telles SCL, Furlan SF, Peruchi BB, Leite CF, Yagihara FT, Campos LD, Ulhôa MA, Cruz MGDR, Beidacki R, Santos RB, de Queiroz SS, Barreto S, Piccin VS, Coelho FMS, Studart L, Assis M, Drager LF. Practice recommendations for the role of physiotherapy in the management of sleep disorders: the 2022 Brazilian Sleep Association Guidelines. Sleep Sci 2022; 15:515-573. [PMID: 36419815 PMCID: PMC9670776 DOI: 10.5935/1984-0063.20220083] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Accepted: 09/19/2022] [Indexed: 08/13/2024] Open
Abstract
This clinical guideline supported by the Brazilian Sleep Association comprises a brief history of the development of Brazilian sleep physiotherapy, outlines the role of the physiotherapist as part of a sleep health team, and describes the clinical guidelines in respect of the management of some sleep disorders by the physiotherapist (including sleep breathing disorders, i.e., obstructive sleep apnea, central sleep apnea, upper airway resistance syndrome, hypoventilation syndromes and overlap syndrome, and pediatric sleep breathing disorders; sleep bruxism; circadian rhythms disturbances; insomnia; and Willis-Ekbom disease/periodic limb movement disorder. This clinical practice guideline reflects the state of the art at the time of publication and will be reviewed and updated as new information becomes available.
Collapse
Affiliation(s)
- Cristina Frange
- Departamento de Neurologia e Neurocirurgia, Escola Paulista de
Medicina (EPM), Universidade Federal de São Paulo (UNIFESP) - São
Paulo - SP - Brazil
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
| | - Aline Marques Franco
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Neurociências e Ciências do
Comportamento, Faculdade de Medicina de Ribeirão Preto, Universidade de
São Paulo (FMRP-USP) - Ribeirão Preto - SP - Brazil
| | - Evelyn Brasil
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Terapia Intensiva, Hospital Israelita Albert
Einstein (HIAE) - São Paulo - SP - Brazil
| | - Raquel Pastrello Hirata
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Laboratório de Pesquisa em Fisioterapia Pulmonar,
Departamento de Fisioterapia, Universidade Estadual de Londrina (UEL) - Londrina -
PR - Brazil
| | - Juliana Arcanjo Lino
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Ciências Médicas, Universidade Federal do
Ceará (UFC) - Fortaleza - CE - Brazil
| | - Daiana Moreira Mortari
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Universidade Federal do Rio Grande do Sul - Porto Alegre - RS -
Brazil
| | - Daisy Satomi Ykeda
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Curso de Fisioterapia, Universidade Estadual do Piauí
(UESPI) - Teresina - PI - Brazil
| | - Mario André Leocádio-Miguel
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Fisiologia e Comportamento, Universidade Federal do
Rio Grande do Norte - Natal - RN - Brazil
| | | | - Luciana Oliveira e Silva
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Ciências da Saúde, Universidade
Federal de Uberlândia (UFU) - Uberlândia - MG - Brazil
| | | | - Sofia Fontanello Furlan
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Unidade de Hipertensão, Instituto do Coração
(InCor), Faculdade de Medicina, Universidade de São Paulo (USP) - São
Paulo - SP - Brazil
| | - Bruno Búrigo Peruchi
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Laboratório de Neurociência, Universidade do Estado
de Santa Catarina (UNESC) - Criciúma - SC - Brazil
| | - Camila Ferreira Leite
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Fisioterapia, UFC; Programas de Mestrado em
Fisioterapia e Funcionalidade, e Mestrado em Ciências Cardiovasculares, UFC -
Fortaleza - CE - Brazil
| | - Fabiana Tokie Yagihara
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Setor de Neurofisiologia Clínica, Departamento de
Neurologia e Neurocirurgia, EPM, UNIFESP - São Paulo - SP - Brazil
| | | | - Melissa Araújo Ulhôa
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Instituto Metropolitano de Ensino Superior, Faculdade de Medicina
do Vale do Aço (UNIVAÇO) - Ipatinga - MG - Brazil
| | | | - Ricardo Beidacki
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Faculdade Inspirar, Unidade Porto Alegre - Porto Alegre - RS -
Brazil
| | - Ronaldo Batista Santos
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Fisioterapia, Hospital Universitário, USP -
São Paulo - Brazil
| | | | - Simone Barreto
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Instituto do Sono, Associação Fundo Incentivo
à Pesquisa - São Paulo - Brazil
| | - Vivien Schmeling Piccin
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Laboratório do Sono, Divisão de Pneumologia do
Instituto do Coração (InCor), FMUSP, USP - São Paulo - SP -
Brazil
| | - Fernando Morgadinho Santos Coelho
- Departamento de Neurologia e Neurocirurgia, Escola Paulista de
Medicina (EPM), Universidade Federal de São Paulo (UNIFESP) - São
Paulo - SP - Brazil
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Psicobiologia, EPM, UNIFESP - São Paulo -
SP - Brazil
| | - Luciana Studart
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Universidade Federal de Pernambuco - Recife - PE - Brazil
| | - Marcia Assis
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Clínica do Sono de Curitiba, Hospital São Lucas -
Curitiba - PR - Brazil
| | - Luciano F. Drager
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Unidade de Hipertensão, Instituto do Coração
(InCor), Faculdade de Medicina, Universidade de São Paulo (USP) - São
Paulo - SP - Brazil
| |
Collapse
|
6
|
Pierucci P, Portacci A, Carpagnano GE, Banfi P, Crimi C, Misseri G, Gregoretti C. The right interface for the right patient in noninvasive ventilation: a systematic review. Expert Rev Respir Med 2022; 16:931-944. [PMID: 36093799 DOI: 10.1080/17476348.2022.2121706] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Research in the field of noninvasive ventilation (NIV) has contributed to the development of new NIV interfaces. However, interface tolerance plays a crucial role in determining the beneficial effects of NIV therapy. AREAS COVERED This systematic review explores the most significant scientific research on NIV interfaces, with a focus on the potential impact that their design might have on treatment adherence and clinical outcomes. The rationale on the choice of the right interface among the wide variety of devices that are currently available is discussed here. EXPERT OPINION The paradigm "The right mask for the right patient" seems to be difficult to achieve in real life. Ranging from acute to chronic settings, the gold standard should include the tailoring of NIV interfaces to patients' needs and preferences. However, such customization may be hampered by issues of economic nature. High production costs and the increasing demand represent consistent burdens and have to be considered when dealing with patient-tailored NIV interfaces. New research focusing on developing advanced and tailored NIV masks should be prioritized; indeed, interfaces should be designed according to the specific patient and clinical setting where they need to be used.
Collapse
Affiliation(s)
- Paola Pierucci
- A. Cardiothoracic Department, Respiratory and Critical care Unit Bari Policlinic University Hospital, B. Section of Respiratory Diseases, Dept. of Basic Medical Science Neuroscience and Sense Organs, University of Bari 'Aldo Moro'
| | - Andrea Portacci
- A. Cardiothoracic Department, Respiratory and Critical care Unit Bari Policlinic University Hospital, B. Section of Respiratory Diseases, Dept. of Basic Medical Science Neuroscience and Sense Organs, University of Bari 'Aldo Moro'
| | - Giovanna Elisiana Carpagnano
- A. Cardiothoracic Department, Respiratory and Critical care Unit Bari Policlinic University Hospital, B. Section of Respiratory Diseases, Dept. of Basic Medical Science Neuroscience and Sense Organs, University of Bari 'Aldo Moro'
| | - Paolo Banfi
- IRCCS Fondazione Don Carlo Gnocchi, Milano,Italy
| | - Claudia Crimi
- Respiratory Medicine Unit, "Policlinico-Vittorio Emanuele San Marco" University Hospital, Catania, Italy
| | | | - Cesare Gregoretti
- Department of Surgical, Oncological and Oral Science (Di.Chir.On.S.), University of Palermo, Italy and Fondazione Istituto "G.Giglio" Cefalù', Palermo, Italy
| |
Collapse
|
7
|
Kang YJ, Cho JH, Park CS. Analysis of risk factors for air leakage in auto-titrating positive airway pressure users: a single-center study. J Clin Sleep Med 2022; 18:75-88. [PMID: 34170231 PMCID: PMC8807919 DOI: 10.5664/jcsm.9504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
STUDY OBJECTIVES Because air leakage from masks is known as a common cause of low adherence to continuous positive airway pressure therapy, we analyzed the risk factors for air leakage related to parameters associated with auto-titrating positive airway pressure, polysomnography, InBody Test, and rhinomanometry. METHODS Usage data and medical records of 120 auto-titrating positive airway pressure users were reviewed retrospectively. All patients used a nasal or pillow mask and were carefully monitored at scheduled follow-ups. RESULTS Use of a pillow mask, sex (male), age, and abdominal fat percentage were significantly associated with high average air leakage. The higher the auto-titrating positive airway pressure average and mean pressure, the more likely patients exhibited high rates of air leakage. The percentage of patients with high average air leakage increased over time (up to 6 months of follow-up). CONCLUSIONS Older male patients using a pillow mask and those with a high abdominal fat percentage and high auto-titrating positive airway pressure may require close follow-up and continuous monitoring for air leakage. Because air leakage from a mask can change over time, mask-sealing capacity should be reassessed and masks should be changed regularly. CITATION Kang YJ, Cho J-H, Park C-S. Analysis of risk factors for air leakage in auto-titrating positive airway pressure users: a single-center study. J Clin Sleep Med. 2022;18(1):75-88.
Collapse
Affiliation(s)
- Yun Jin Kang
- Department of Otolaryngology-Head and Neck Surgery, St. Vincent’s Hospital, College of Medicine, The Catholic University of Korea, Suwon, Republic of Korea
| | - Jin-Hee Cho
- Department of Otolaryngology-Head and Neck Surgery, Yeouido St. Mary Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Chan-Soon Park
- Department of Otolaryngology-Head and Neck Surgery, St. Vincent’s Hospital, College of Medicine, The Catholic University of Korea, Suwon, Republic of Korea,Address correspondence to: Chan-Soon Park, MD, PhD, Department of Otorhinolaryngology-Head and Neck Surgery, St. Vincent’s Hospital, College of Medicine, The Catholic University of Korea, 93 Jungbu Daero (Ji-dong), Suwon Si, Paldal-gu, Gyeonggi-Do, 16247, Republic of Korea; Tel: +82-31-249-8968; Fax: +82-31-257-3752;
| |
Collapse
|
8
|
Efficacy of nasal masks versus nasal pillows masks during continuous positive airway pressure titration for patients with obstructive sleep apnea. Sleep Breath 2021; 25:1-8. [PMID: 33403598 DOI: 10.1007/s11325-020-02251-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 11/02/2020] [Accepted: 11/12/2020] [Indexed: 10/22/2022]
Abstract
PURPOSE Nasal masks are usually the first choice for CPAP therapy, but patients may experience side effects. There are limited data regarding the efficacy of nasal pillows masks during CPAP titration. This study aimed to compare the polysomnography outcomes during CPAP titration while comparing two types of masks (nasal and pillows) and to assess whether or not the patient characteristics differed between mask preferences. METHODS In a sleep-disorders clinic, we prospectively analyzed all patients undergoing CPAP titration for three consecutive months. CPAP pressures were manually titrated. Anthropometric data (age, sex, body mass index, and neck and waist circumferences) and OSA severity were documented. Patients completed a self-administered questionnaire that measured nasal obstruction (NOSE scale). Before titration, both types of masks were presented to patients, and each of them chose the one they preferred. RESULTS Of 157 patients, 55% (n = 86) used nasal masks, and 45% (n = 71) used nasal pillows masks. There was no difference according to mask type chosen by age, sex, body mass index, neck and waist circumferences, and NOSE scale. Polysomnography outcomes were similar between the mask groups. The mean CPAP level was 9.4 ± 1.8 cm H2O for nasal masks and 9.1 ± 2.0 cm H2O for nasal pillows (p = 0.61). Residual apnea-hypopnea index was 3.0 ± 2.8 events/h for nasal mask and 3.5 ± 4.1 events/h for pillow mask (p = 0.28). Baseline AHI, body mass index, neck and waist circumferences, and residual AHI were independent predictors of a higher CPAP pressure for both groups (p < 0.0001). CONCLUSIONS Nasal pillows masks seem to be as effective as nasal masks and may be considered to be an initial choice for CPAP titration.
Collapse
|
9
|
Ma Z, Hyde P, Drinnan M, Munguia J. Development of a smart-fit system for CPAP interface selection. Proc Inst Mech Eng H 2021; 235:44-53. [PMID: 32988316 PMCID: PMC7780270 DOI: 10.1177/0954411920959879] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Accepted: 08/27/2020] [Indexed: 12/05/2022]
Abstract
Continuous Positive Airway Pressure (CPAP) therapy is commonly prescribed for longstanding, acute cases of Obstructive Sleep Apnea (OSA) during which patients must wear a tight-fitting breathing mask overnight for the duration of the treatment. Because this condition frequently leads to the permanent use of CPAP masks, interface selection is a crucial factor influencing the treatment quality and effectiveness. Masks/interface selection is normally performed on a trial an error basis with clinicians informing their selection based on OSA-related factors with basic fitting feedback from patients. However, it is not uncommon for patients to abandon the treatment or request additional consultations due to ill-fitting CPAP mask with the main sources of discomfort being perceived air leakage and mask/strap overtightening leading to skin damage. This work introduces a novel system (Smart-Fit), for CPAP interface selection using advanced digital technologies, such as Reverse Engineering and Computational Modeling (Finite Element Analysis) which are paired to evaluate and determine the best fitting interface for each clinical case. The model simplifies the number of 3D facial landmarks to 12 and established that a 2 mm scan resolution is enough for accurate scans. The Von Mises stress map in ANSYS serves as an indicator of potential high-pressure areas, triggering the need for a chance of mask size. Current results indicate the Smart Fit System can enable a "best fit CPAP interface" to be selected considering individual's physical characteristics and existing CPAP interface configurations. The development of the Smart Fit System is an evolution compared to traditional CPAP interface selection approach, which optimizes the CPAP interface selection process.
Collapse
Affiliation(s)
- Zhichao Ma
- School of Engineering, Newcastle University,
Newcastle upon Tyne, UK
| | - Philip Hyde
- School of Engineering, Newcastle University,
Newcastle upon Tyne, UK
| | - Michael Drinnan
- School of Engineering, Newcastle University,
Newcastle upon Tyne, UK
| | - Javier Munguia
- School of Engineering, Newcastle University,
Newcastle upon Tyne, UK
| |
Collapse
|
10
|
Treatment of Obstructive Sleep Apnea: Achieving Adherence to Positive Airway Pressure Treatment and Dealing with Complications. Sleep Med Clin 2020; 15:227-240. [PMID: 32386697 DOI: 10.1016/j.jsmc.2020.02.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Obstructive sleep apnea is a common and treatable condition, but therapeutic adherence is limited by numerous factors. Despite advances in positive airway pressure (PAP) technology and a multitude of effective pharmacologic and behavioral therapeutic interventions to overcome the most common barriers to PAP, adherence has not increased significantly over the past 30 years. This review aims to identify the most important factors that impact adherence, common barriers to treatment, and evidence-based treatment strategies to maximize the effectiveness of PAP treatment. Complications of PAP treatment and mitigation techniques are also discussed.
Collapse
|
11
|
Castro-Codesal ML, Olmstead DL, MacLean JE. Mask interfaces for home non-invasive ventilation in infants and children. Paediatr Respir Rev 2019; 32:66-72. [PMID: 31130424 DOI: 10.1016/j.prrv.2019.03.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Accepted: 03/15/2019] [Indexed: 12/25/2022]
Abstract
The selection of the mask interface for non-invasive ventilation (NIV) is recognized to be an essential part for therapy success. While nasal masks are the first recommended option in children and adults, there are indications for other mask types such as intolerance or complications from nasal masks. Evidence comparing performance, adherence and complication risk among mask interfaces in pediatrics is, however, scarce and information is often extrapolated from adult studies. Given this gap in knowledge and the lack of guidelines on NIV initiation in children, mask selection often relies on the clinicians' knowledge and expertise. Careful mask selection, a well-fitting headgear and time investment for mask desensitization are some important recommendations for adequate mask adaptation in children. Frequent mask-related complications include nasal symptoms, unintentional leak, mask displacement, skin injury, and midface hypoplasia. Close monitoring and a pro-active approach may help to minimize complications and promote the optimal use of home NIV.
Collapse
Affiliation(s)
- Maria L Castro-Codesal
- Department of Pediatrics, University of Alberta, 116 St & 85 Ave, Edmonton, AB T6G 2R3, Canada; Stollery Children's Hospital, 8440 112 St NW, Edmonton, AB T6G 2B7, Canada.
| | - Deborah L Olmstead
- Stollery Children's Hospital, 8440 112 St NW, Edmonton, AB T6G 2B7, Canada
| | - Joanna E MacLean
- Department of Pediatrics, University of Alberta, 116 St & 85 Ave, Edmonton, AB T6G 2R3, Canada; Stollery Children's Hospital, 8440 112 St NW, Edmonton, AB T6G 2B7, Canada
| |
Collapse
|
12
|
Blanco M, Ernst G, Salvado A, Borsini E. Impact of Mask Type on the Effectiveness of and Adherence to Unattended Home-Based CPAP Titration. SLEEP DISORDERS 2019; 2019:4592462. [PMID: 31019811 PMCID: PMC6452566 DOI: 10.1155/2019/4592462] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Accepted: 01/28/2019] [Indexed: 11/24/2022]
Abstract
OBJECTIVES To compare interfaces performance during home-based automatic titration (APAP). METHODS Retrospective study based on APAP titration from Obstructive Sleep Apnea Syndrome (OSA) patients. RESULTS 707 patients, 513 men (70.6%), were titrated. Masks were 104 pillows (14.7%), group I (GI); 532 nasal (75.2%), group II (GII); and 71 oronasal masks (10%), group III (GIII). We found differences in effective pressure to the device (P90/P95) (GI: 7.13±1.9 vs. GII: 8.3±2.1 vs. GIII: 9.3±2.6 cmH2O, p <0.001) but not in final pressure titrated manually (GI: 7.9±1.4 vs. GII: 8.6±1.6 vs. GIII: 9.2±1.9 cm of H2O, p >0.5), where lower residual AHI for pillows was p <0.001 and leaks for nasal were p <0.001. No differences were found in compliance (hours) (GI: 6.3±1.2 vs. GII: 6.2±1.1 vs. GIII: 6.1±1.0, p <0.4). CONCLUSION During auto-adjusting titration by CPAP-naïve patients, nasal masks had lower leak rates and nasal pillows presented a similar performance.
Collapse
Affiliation(s)
- Magalí Blanco
- Sleep and Ventilation Unit, Hospital Británico de Buenos Aires, Argentina
| | - Glenda Ernst
- Center for Respiratory Medicine, Hospital Británico de Buenos Aires, Argentina
| | - Alejandro Salvado
- Center for Respiratory Medicine, Hospital Británico de Buenos Aires, Argentina
| | - Eduardo Borsini
- Sleep and Ventilation Unit, Hospital Británico de Buenos Aires, Argentina
| |
Collapse
|
13
|
Patil SP, Ayappa IA, Caples SM, Kimoff RJ, Patel SR, Harrod CG. Treatment of Adult Obstructive Sleep Apnea With Positive Airway Pressure: An American Academy of Sleep Medicine Systematic Review, Meta-Analysis, and GRADE Assessment. J Clin Sleep Med 2019; 15:301-334. [PMID: 30736888 DOI: 10.5664/jcsm.7638] [Citation(s) in RCA: 330] [Impact Index Per Article: 66.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 01/14/2019] [Indexed: 02/07/2023]
Abstract
INTRODUCTION The purpose of this systematic review is to provide supporting evidence for the clinical practice guideline for the treatment of obstructive sleep apnea (OSA) in adults using positive airway pressure (PAP). METHODS The American Academy of Sleep Medicine commissioned a task force of experts in sleep medicine. A systematic review was conducted to identify studies that compared the use of PAP with no treatment as well as studies that compared different PAP modalities. Meta-analyses were performed to determine the clinical significance of using PAP in several modalities (ie, continuous PAP, auto-adjusting PAP, and bilevel PAP), to treat OSA in adults. In addition, meta-analyses were performed to determine the clinical significance of using an in-laboratory versus ambulatory strategy for the initiation of PAP, educational and behavioral interventions, telemonitoring, humidification, different mask interfaces, and flexible or modified pressure profile PAP in conjunction with PAP to treat OSA in adults. Finally, the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) process was used to assess the evidence for making recommendations. RESULTS The literature search resulted in 336 studies that met inclusion criteria; 184 studies provided data suitable for meta-analyses. The data demonstrated that PAP compared to no treatment results in a clinically significant reduction in disease severity, sleepiness, blood pressure, and motor vehicle accidents, and improvement in sleep-related quality of life in adults with OSA. In addition, the initiation of PAP in the home demonstrated equivalent effects on patient outcomes when compared to an in-laboratory titration approach. The data also demonstrated that the use of auto-adjusting or bilevel PAP did not result in clinically significant differences in patient outcomes compared with standard continuous PAP. Furthermore, data demonstrated a clinically significant improvement in PAP adherence with the use of educational, behavioral, troubleshooting, and telemonitoring interventions. Systematic reviews for specific PAP delivery method were also performed and suggested that nasal interfaces compared to oronasal interfaces have improved adherence and slightly greater reductions in OSA severity, heated humidification compared to no humidification reduces some continuous PAP-related side effects, and pressure profile PAP did not result in clinically significant differences in patient outcomes compared with standard continuous PAP.
Collapse
Affiliation(s)
| | - Indu A Ayappa
- Icahn School of Medicine at Mount Sinai, New York, New York
| | | | - R Joh Kimoff
- McGill University Health Centre, Montreal, Quebec, Canada
| | | | | |
Collapse
|
14
|
Ma Z, Drinnan M, Hyde P, Munguia J. Mask interface for continuous positive airway pressure therapy: selection and design considerations. Expert Rev Med Devices 2018; 15:725-733. [PMID: 30227754 DOI: 10.1080/17434440.2018.1525291] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
INTRODUCTION Continuous positive airway pressure (CPAP) therapy is a clinical treatment for moderate or severe obstructive sleep apnea (OSA). Commercial CPAP mask designs normally come in standard sizes and the configuration is not commonly tailored to the patients' characteristics such as face topology, skin sensitivity, and severity of OSA syndrome; however, an optimal mask/interface selection is a key factor influencing the compliance and effectiveness of CPAP treatment. AREAS COVERED This review investigates the conventional CPAP mask design, its effect on OSA treatment, and the related risk factors that can lead to skin damage after long-term repeated use. Through a literature search on common databases, Scopus, PubMed, and Google Scholar, we identified reported facts on the influence of the mask interface and current trends toward customized devices. EXPERT COMMENTARY There is potential for optimizing the CPAP mask fit by adapting the interface to the patients' individual characteristics. This holds particularly true for users with abnormal features or simply outside conventional industry sizing standards. Enabling technologies for undertaking this adaptation include reverse engineering, computational modeling, and additive manufacturing. There is to date no integrated system that integrates those elements into a standard solution, but several studies have shown its effectiveness for specific cohorts.
Collapse
Affiliation(s)
- Zhichao Ma
- a Department of Mechanical Engineering , Newcastle University, School of Engineering , Newcastle upon Tyne , UK
| | - Michael Drinnan
- b Northern Medical Physical and Clinical Engineering department , NHS Foundation Trust , Newcastle upon Tyne , UK
| | - Philip Hyde
- a Department of Mechanical Engineering , Newcastle University, School of Engineering , Newcastle upon Tyne , UK
| | - Javier Munguia
- a Department of Mechanical Engineering , Newcastle University, School of Engineering , Newcastle upon Tyne , UK
| |
Collapse
|
15
|
Goh KJ, Soh RY, Leow LC, Toh ST, Song PR, Hao Y, Lee KCH, Tan GL, Ong TH. Choosing the right mask for your Asian patient with sleep apnoea: A randomized, crossover trial of CPAP interfaces. Respirology 2018; 24:278-285. [PMID: 30189465 DOI: 10.1111/resp.13396] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Revised: 08/06/2018] [Accepted: 08/12/2018] [Indexed: 12/22/2022]
Abstract
BACKGROUND AND OBJECTIVE A major challenge with the treatment of obstructive sleep apnoea (OSA) is adherence to continuous positive airway pressure (CPAP) therapy. Mask tolerability is an important determinant of adherence, however evidence to guide selection of mask interfaces is lacking. METHODS We conducted a randomized crossover trial of mask interfaces in CPAP therapy for moderate-to-severe OSA to assess adherence and efficacy of CPAP therapy with nasal mask, nasal pillow and oronasal masks. Demographic data, Nasal Obstruction Symptom Evaluation (NOSE) scores and craniofacial measurements were also analysed for associations with adherence with oronasal masks. RESULTS Eighty-five patients were included in the study (mean ± SD age: 46 ± 12 years; body mass index: 29.9 ± 5.6 kg/m2 ; apnoea-hypopnoea index (AHI): 53.6 ± 24.0 events/h). Patients had better adherence with nasal masks (average night use: 3.96 ± 2.26 h/night) compared to oronasal masks (3.26 ± 2.18 h/night, P < 0.001) and nasal pillows (3.48 ± 2.20 h/night, P = 0.007). Residual AHI was higher with oronasal masks (7.2 ± 5.2) compared to nasal masks (4.0 ± 4.2, P < 0.001) and nasal pillows (4.1 ± 3.3, P < 0.001). Twenty-two (25.9%) patients had the best adherence with oronasal masks (4.22 ± 2.14 vs 2.93 ± 2.12 h/night, P = 0.016). These patients had lower NOSE scores (15 (0-35) vs 40 (10-55), P = 0.024) and larger menton-labrale inferioris/biocular width ratios (31 ± 3% vs 28 ± 4%, P = 0.019). CONCLUSION Nasal masks are the preferred interface during CPAP initiation. Patients with less nasal obstruction and a proportionally increased chin-lower lip distance to mid-face width may have better CPAP adherence with an oronasal mask interface.
Collapse
Affiliation(s)
- Ken Junyang Goh
- Department of Respiratory and Critical Care Medicine, Singapore General Hospital, Singapore
| | - Rui Ya Soh
- Department of Respiratory and Critical Care Medicine, Singapore General Hospital, Singapore.,Sleep Disorder Unit, Singapore General Hospital, Singapore
| | - Leong Chai Leow
- Department of Respiratory and Critical Care Medicine, Singapore General Hospital, Singapore.,Sleep Disorder Unit, Singapore General Hospital, Singapore
| | - Song Tar Toh
- Sleep Disorder Unit, Singapore General Hospital, Singapore.,Department of Otolaryngology, Singapore General Hospital, Singapore
| | - Pei Rong Song
- Sleep Disorder Unit, Singapore General Hospital, Singapore
| | - Ying Hao
- Health Services Research Unit (HSRU), Division of Medicine, Singapore General Hospital, Singapore
| | - Ken Cheah Hooi Lee
- Department of Respiratory and Critical Care Medicine, Singapore General Hospital, Singapore
| | - Gan Liang Tan
- Department of Respiratory and Critical Care Medicine, Singapore General Hospital, Singapore
| | - Thun How Ong
- Department of Respiratory and Critical Care Medicine, Singapore General Hospital, Singapore.,Sleep Disorder Unit, Singapore General Hospital, Singapore
| |
Collapse
|
16
|
Tan HL, Kheirandish-Gozal L, Gozal D. Adenotonsillectomy in Pediatric OSA: Time to Look Elsewhere. CURRENT SLEEP MEDICINE REPORTS 2018. [DOI: 10.1007/s40675-018-0122-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
17
|
Oronasal mask may compromise the efficacy of continuous positive airway pressure on OSA treatment: is there evidence for avoiding the oronasal route? Curr Opin Pulm Med 2018; 22:555-62. [PMID: 27607153 DOI: 10.1097/mcp.0000000000000318] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE OF REVIEW Continuous positive airway pressure (CPAP) delivered by nasal mask is the gold standard treatment for obstructive sleep apnea (OSA). However, oral and oronasal masks are also available. We considered experimental evidence and reviewed clinical trials that evaluated the impact of oral and oronasal mask on OSA treatment. RECENT FINDINGS One recent study in 18 OSA patients that slept with a customized oronasal mask with two sealed compartments showed that the change of CPAP flow from nasal to oronasal and oral caused upper airway obstruction because of posterior displacement of the tongue demonstrated by nasoendoscopy. Oral masks use a mouthpiece that may stabilize the jaw and the tongue and have shown to be effective. However, oral masks are not widely used in clinical practice. Four out of five observational studies and all five reviewed randomized studies showed a worse performance of oronasal when compared with nasal masks. Oronasal masks were associated with higher residual apnea-hypopnea index, lower adherence, more leaks, and less satisfaction than nasal mask in the majority of the studies. SUMMARY Nasal CPAP must be the first choice to treat OSA. Patients on oronasal mask should be carefully followed. VIDEO ABSTRACT.
Collapse
|
18
|
Lanza A, Mariani S, Sommariva M, Campana C, Rubino A, Nichelatti M, Proserpio P, Nobili L. Continuous positive airway pressure treatment with nasal pillows in obstructive sleep apnea: long-term effectiveness and adherence. Sleep Med 2018; 41:94-99. [DOI: 10.1016/j.sleep.2017.08.024] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2017] [Revised: 07/14/2017] [Accepted: 08/02/2017] [Indexed: 11/30/2022]
|
19
|
Treatment of Obstructive Sleep Apnea: Achieving Adherence to Positive Airway Pressure Treatment and Dealing with Complications. Sleep Med Clin 2017; 12:551-564. [PMID: 29108610 DOI: 10.1016/j.jsmc.2017.07.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Obstructive sleep apnea is a common and treatable condition, but therapeutic adherence is limited by numerous factors. Despite advances in positive airway pressure (PAP) technology and a multitude of effective pharmacologic and behavioral therapeutic interventions to overcome the most common barriers to PAP, adherence has not increased significantly over the past 30 years. This review aims to identify the most important factors that impact adherence, common barriers to treatment, and evidence-based treatment strategies to maximize the effectiveness of PAP treatment. Complications of PAP treatment and mitigation techniques are also discussed.
Collapse
|
20
|
Choosing the right interface for positive airway pressure therapy in patients with obstructive sleep apnea. Sleep Breath 2017; 21:569-575. [DOI: 10.1007/s11325-017-1490-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2016] [Revised: 02/08/2017] [Accepted: 03/14/2017] [Indexed: 10/19/2022]
|
21
|
Lebret M, Martinot JB, Arnol N, Zerillo D, Tamisier R, Pepin JL, Borel JC. Factors Contributing to Unintentional Leak During CPAP Treatment: A Systematic Review. Chest 2016; 151:707-719. [PMID: 27986462 DOI: 10.1016/j.chest.2016.11.049] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 11/09/2016] [Accepted: 11/29/2016] [Indexed: 12/30/2022] Open
Abstract
CPAP is the first-line treatment for moderate to severe OSA syndrome. Up to 25% of patients with OSA syndrome discontinue CPAP treatment due to side effects. Unintentional leakage and its associated annoying consequences are the most frequently reported adverse effects of CPAP. Successive technological improvements have not succeeded in addressing this issue. A systematic review was conducted (1) to assess the impact of different technological advances on unintentional leaks and (2) to determine if any patient characteristics have already been identified as determinants of unintentional leakage. No CPAP modality was superior to another in reducing unintentional leaks and, surprisingly, oronasal masks were associated with higher unintentional leaks. Nasal obstruction, older age, higher BMI, central fat distribution, and male sex might be associated with an increased risk of unintentional leakage. Such leaks remain an important problem. Further studies are needed to improve the understanding of underlying clinical factors so that patients at risk of unintentional leaks may be identified and individualized solutions applied.
Collapse
Affiliation(s)
- Marius Lebret
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France.
| | | | - Nathalie Arnol
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France
| | - Daniel Zerillo
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France
| | - Renaud Tamisier
- Thorax and Vessels Division, Sleep Laboratory, Grenoble Alpes University, HP2 Laboratory, INSERM U 1042, Grenoble, France
| | - Jean-Louis Pepin
- Thorax and Vessels Division, Sleep Laboratory, Grenoble Alpes University, HP2 Laboratory, INSERM U 1042, Grenoble, France
| | - Jean-Christian Borel
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France; Thorax and Vessels Division, Sleep Laboratory, Grenoble Alpes University, HP2 Laboratory, INSERM U 1042, Grenoble, France
| |
Collapse
|
22
|
Impact of a New Nasal Pillows Mask on Patients' Acceptance, Compliance, and Willingness to Remain on CPAP Therapy. SLEEP DISORDERS 2016; 2016:6713236. [PMID: 27648308 PMCID: PMC5014980 DOI: 10.1155/2016/6713236] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Accepted: 08/09/2016] [Indexed: 12/03/2022]
Abstract
Aim. Continuous positive airway pressure (CPAP) masks are a key factor in patient compliance. This program assessed the performance of a new nasal pillows mask (NPM) on a variety of new and established obstructive sleep apnea (OSA) patients using CPAP therapy. Methods. Five programs were developed to assess the new NPM [AirFit P10, ResMed] on naïve patients; patients established on another NPM; patients using a nasal mask; patients with low CPAP compliance; and patients who wished to stop using CPAP therapy. Results. A total of 212 patients were included. In naïve patients, CPAP usage after 3 months was 5.9 ± 1.7 hours/night, compared with the control group at 4.6 ± 2.4 hours/night (p < 0.05). In patients established on another NPM, usage improved to 7.4 ± 1.1 hours/night versus 6.7 ± 1.4 (p = 0.001). 78% of nasal mask users wished to continue using the new NPM. Low compliance patients improved with an average of 0.87 hours/night (p = 0.001) when using the new NPM. In patients at the point of quitting CPAP, 60% continued with therapy using the new NPM. Conclusion. The new NPM mask performed well in a variety of clinical groups of OSA patients receiving CPAP therapy and shows that technical advances in CPAP masks can improve patient compliance.
Collapse
|
23
|
Hawkins SMM, Jensen EL, Simon SL, Friedman NR. Correlates of Pediatric CPAP Adherence. J Clin Sleep Med 2016; 12:879-84. [PMID: 27092702 DOI: 10.5664/jcsm.5892] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2015] [Accepted: 03/03/2016] [Indexed: 12/18/2022]
Abstract
STUDY OBJECTIVES Obstructive sleep apnea (OSA) is a common pediatric condition characterized by recurrent partial or complete cessation of airflow during sleep, typically due to inadequate upper airway patency. Continuous positive airway pressure (CPAP) is a therapeutic option that reduces morbidity. Despite efforts to promote use, CPAP adherence is poor in both pediatric and adult populations. We sought to determine whether demographics, insurance status, OSA severity, therapeutic pressure, or comorbid conditions were associated with pediatric CPAP adherence. METHODS A retrospective review of adherence download data was performed on all pediatric patients with initiation or adjustment of CPAP treatment over a one-year period with documented in-laboratory CPAP titration. Patients were grouped as CPAP adherent or non-adherent, where adherence was defined as > 70% nightly use and average usage ≥ 4 hours per night. Differences between the groups were analyzed by χ(2) test. RESULTS Overall, nearly half of participants were CPAP adherent (49%, 69/140). Of the demographic data collected (age, ethnicity, sex, insurance status), only female sex was associated with better adherence (60.9% vs 39.5% of males adherent; odds ratio [OR] = 2.41, 95%CI = 1.20-4.85; p = 0.01). Severity of OSA (diagnostic apnea-hypopnea index [AHI] and degree of hypoxemia), therapeutic pressure, and residual AHI did not impact CPAP adherence (p > 0.05). Patients with developmental delay (DD) were more likely to be adherent with CPAP than those without a DD diagnosis (OR = 2.55, 95%CI = 1.27-5.13; p = 0.007). Female patients with trisomy 21 tended to be more adherent, but this did not reach significance or account for the overall increased adherence associated with female sex. CONCLUSIONS Our study demonstrates that adherence to CPAP therapy is poor but suggests that female sex and developmental delay are associated with better adherence. These findings support efforts to understand the pathophysiology of and to develop adherence-promoting and alternative interventions for pediatric OSA.
Collapse
Affiliation(s)
- Stephen M M Hawkins
- Department of Pediatric Pulmonology, University of Colorado School of Medicine, Aurora, CO.,The Breathing Institute, Children's Hospital Colorado, Aurora, CO
| | - Emily L Jensen
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, CO.,Department of Pediatric Otolaryngology, Children's Hospital Colorado, Aurora, CO
| | - Stacey L Simon
- Department of Pediatric Pulmonology, University of Colorado School of Medicine, Aurora, CO.,The Breathing Institute, Children's Hospital Colorado, Aurora, CO
| | - Norman R Friedman
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, CO.,Department of Pediatric Otolaryngology, Children's Hospital Colorado, Aurora, CO
| |
Collapse
|
24
|
Neuzeret PC, Morin L. Impact of different nasal masks on CPAP therapy for obstructive sleep apnea: a randomized comparative trial. CLINICAL RESPIRATORY JOURNAL 2016; 11:990-998. [PMID: 26780403 DOI: 10.1111/crj.12452] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 12/11/2015] [Accepted: 01/04/2016] [Indexed: 01/07/2023]
Abstract
INTRODUCTION Patient interface is important for the success of continuous positive airway pressure (CPAP), but few trials have examined the influence of mask choice on CPAP adherence. OBJECTIVES To compare the impact of different nasal masks on CPAP in patients with newly-diagnosed obstructive sleep apnea (OSA). METHODS OSA patients were randomized in a 2:3 ratio to receive CPAP via different first-line nasal masks: ResMed Mirage FX® (MFX) or control mask (Fisher & Paykel Zest® , HC407® or Philips EasyLife® ). Mask acceptance, CPAP compliance and Home Care Provider (HCP) interventions were compared between groups after 3 months of CPAP therapy using modified intent-to-treat (mITT; after exclusion of patients with mouth leaks during CPAP initiation) and on-treatment (OT; CPAP adherent) analyses. RESULTS Of 285 randomized patients, 90 requiring a full-face mask were excluded, leaving 195 and 151 in the mITT and OT analyses, respectively. Mask acceptance rate was higher in the MFX versus control group (mITT: 79% vs 68%, P = 0.067; OT: 90% vs 76%, P = 0.022). CPAP compliance was higher (5.9 ± 1.8 vs 5.1 ± 1.6 h/night, P = 0.011) and nasal mask issue-related HCP visits lower (3% vs 17%, P = 0.006) in the MFX group. Nasal mask failures due to mask discomfort (5% vs 1%) or unintentional leakage (5% vs 0%) were higher in control vs MFX group. Mask acceptance was significantly associated with fewer mask leaks (P = 0.002) and higher pressure therapy (P = 0.042). CONCLUSIONS This study highlights differences between nasal masks for CPAP delivery and shows that initial mask selection can influence adherence and healthcare utilization during CPAP.
Collapse
|
25
|
Bachour A, Vitikainen P, Maasilta P. Rates of initial acceptance of PAP masks and outcomes of mask switching. Sleep Breath 2015; 20:733-8. [DOI: 10.1007/s11325-015-1292-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2015] [Revised: 10/23/2015] [Accepted: 11/23/2015] [Indexed: 11/28/2022]
|
26
|
Andrade RGSD, Piccin VS, Nascimento JA, Viana FML, Genta PR, Lorenzi-Filho G. Impact of the type of mask on the effectiveness of and adherence to continuous positive airway pressure treatment for obstructive sleep apnea. J Bras Pneumol 2015; 40:658-68. [PMID: 25610507 PMCID: PMC4301251 DOI: 10.1590/s1806-37132014000600010] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2014] [Accepted: 06/27/2014] [Indexed: 11/22/2022] Open
Abstract
Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect.
Collapse
Affiliation(s)
- Rafaela Garcia Santos de Andrade
- University of São Paulo, School of Medicine, Hospital das Clínicas, São Paulo, Brazil. Sleep Laboratory, Department of Pulmonology, Heart Institute, University of São Paulo School of Medicine Hospital das Clínicas, São Paulo, Brazil
| | - Vivien Schmeling Piccin
- University of São Paulo, School of Medicine, Heart Institute, São Paulo, Brazil. Sleep Laboratory, Department of Pulmonology, Heart Institute, University of São Paulo School of Medicine Hospital das Clínicas, São Paulo, Brazil
| | - Juliana Araújo Nascimento
- University of São Paulo, School of Medicine, Hospital das Clínicas, São Paulo, Brazil. Sleep Laboratory, Department of Pulmonology, Heart Institute, University of São Paulo School of Medicine Hospital das Clínicas, São Paulo, Brazil
| | - Fernanda Madeiro Leite Viana
- University of São Paulo, School of Medicine, Hospital das Clínicas, São Paulo, Brazil. Sleep Laboratory, Department of Pulmonology, Heart Institute, University of São Paulo School of Medicine Hospital das Clínicas, São Paulo, Brazil
| | - Pedro Rodrigues Genta
- University of São Paulo, School of Medicine, Hospital das Clínicas, Boston, MA, USA. Sleep Laboratory, Department of Pulmonology, Heart Institute, University of São Paulo School of Medicine Hospital das Clínicas, São Paulo, Brazil; and Postdoctoral Student, Division of Sleep Medicine, Brigham and Women's Hospital/Harvard University, Boston (MA) USA
| | - Geraldo Lorenzi-Filho
- University of São Paulo, School of Medicine, Hospital das Clínicas, São Paulo, Brazil. Sleep Laboratory, Department of Pulmonology, Heart Institute, University of São Paulo School of Medicine Hospital das Clínicas, São Paulo, Brazil
| |
Collapse
|
27
|
Zhu X, Wimms AJ, Benjafield AV. Assessment of the performance of nasal pillows at high CPAP pressures. J Clin Sleep Med 2014; 9:873-7. [PMID: 23997699 DOI: 10.5664/jcsm.2984] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
STUDY OBJECTIVES Compliance with CPAP therapy remains an issue despite its effectiveness. Mask selection is likely to affect a patients experience with CPAP, and multiple mask options are currently available. Nasal pillows have less contact with the face compared to nasal masks and may benefit patients by minimizing side effects; however, they are infrequently used at high CPAP pressures. The aim of this study was to examine the performance of nasal pillows at pressures ≥ 12 cm H2O compared with nasal masks. METHODS Twenty-one subjects were recruited. Participants were randomized to Swift FX nasal pillows and their current nasal mask for 7 consecutive nights each in a prospective crossover trial. Objective device data and subjective feedback were collected. RESULTS There were no differences in objective device data of nasal pillows vs. nasal masks: Daily Usage 7.4 ± 1.4 vs. 7.2 ± 1.4 (h/night); 95(th)%ile Leak 28.6 ± 13.5 vs. 27.9 ± 17.9 (L/min); AHI 1.9 ± 1.3 vs. 1.7 ± 1.1, respectively (all p-values > 0.05). There were no differences between the nasal pillows and nasal masks for subjective ratings of comfort, seal, red marks, side effects such as jetting and dry nose/mouth, and overall performance (all p-values > 0.05). The nasal pillows were rated to be less obtrusive and claustrophobic (both p-values < 0.01), but less stable (p = 0.04). Overall preference was 50% nasal pillows, 45% nasal masks; 5% found no difference. CONCLUSION Nasal pillows are as efficacious as nasal masks at CPAP pressures ≥ 12 cm H2O and are a suitable option for patients requiring high CPAP pressures. CLINICAL TRIAL REGISTRATION NIH Clinical Trials Registry. http://clinicaltrials.gov. TITLE Nasal Pillows at High CPAP Pressure. Identifier: NCT01690923.
Collapse
Affiliation(s)
- Xueling Zhu
- ResMed Science Center, ResMed Ltd, Sydney, Australia.
| | | | | |
Collapse
|
28
|
Crawford MR, Espie CA, Bartlett DJ, Grunstein RR. Integrating psychology and medicine in CPAP adherence – New concepts? Sleep Med Rev 2014; 18:123-39. [DOI: 10.1016/j.smrv.2013.03.002] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2012] [Revised: 03/07/2013] [Accepted: 03/08/2013] [Indexed: 12/11/2022]
|
29
|
|
30
|
Wickwire EM, Lettieri CJ, Cairns AA, Collop NA. Maximizing Positive Airway Pressure Adherence in Adults. Chest 2013; 144:680-693. [DOI: 10.1378/chest.12-2681] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
|
31
|
Colrain IM, Black J, Siegel LC, Bogan RK, Becker PM, Farid-Moayer M, Goldberg R, Lankford DA, Goldberg AN, Malhotra A. A multicenter evaluation of oral pressure therapy for the treatment of obstructive sleep apnea. Sleep Med 2013; 14:830-7. [PMID: 23871259 DOI: 10.1016/j.sleep.2013.05.009] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2012] [Revised: 03/14/2013] [Accepted: 05/07/2013] [Indexed: 10/26/2022]
Abstract
OBJECTIVE We aimed to evaluate the impact of a novel noninvasive oral pressure therapy (OPT) (Winx®, ApniCure) system on polysomnographic measures of sleep-disordered breathing, sleep architecture, and sleep stability in obstructive sleep apnea (OSA). SUBJECTS AND METHODS A 4-week, multicenter, prospective, open-label, randomized, crossover, first-night order of control vs treatment, single-arm trial was conducted in five American Academy of Sleep Medicine (AASM) - accredited sleep clinics and one research laboratory. Sixty-three subjects (analysis cohort) were studied from a screening cohort of 367 subjects. The analysis cohort was 69.8% men, ages 53.6±8.9 years (mean±SD), body mass index of 32.3±4.5kg/m(2), with mild to severe OSA. At treatment initiation, subjects received random assignment to one night with and one without (control) treatment, and they were assessed again following 28 nights of treatment. Breathing and sleep architecture were assessed each night based on blind scoring by a single centralized scorer using AASM criteria. RESULTS Average nightly usage across the take-home period was 6.0±1.4h. There were no severe or serious device-related adverse events (AEs). Median apnea-hypopnea index (AHI) was 27.5 events per hour on the control night, 13.4 events per hour on the first treatment night, and 14.8 events per hour after 28days of treatment. A clinically significant response (treatment AHI ⩽10/h and ⩽50% of control values) was seen in 20 of the 63 subjects evaluated. Rapid eye movement percentage (REM%) was significantly increased, and N1%, stage shifts to N1 sleep, overall stage shifts, total awakenings, and arousals per hour were all significantly reduced at both treatment nights compared to controls. Mean Epworth sleepiness scale (ESS) was significantly reduced from 12.1 to 8.6 (Cohen d effect size, 0.68) in those untreated for two or more weeks prior to OPT study participation and remained unchanged in subjects who directly switched from continuous positive airway pressure (CPAP) therapy to OPT. CONCLUSION Clinically significant improvements in sleep quality and continuity, AHI, ODI, ESS, and overall clinical status were achieved in an easily identified subgroup. OPT was safe and well-tolerated and nightly usage was high.
Collapse
|
32
|
Bachour A, Vitikainen P, Virkkula P, Maasilta P. CPAP interface: satisfaction and side effects. Sleep Breath 2012; 17:667-72. [PMID: 22763499 DOI: 10.1007/s11325-012-0740-0] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2012] [Revised: 06/11/2012] [Accepted: 06/19/2012] [Indexed: 11/30/2022]
Abstract
PURPOSE This study aimed to evaluate the care receiver's satisfaction with the continuous positive airway pressure (CPAP) interfaces. METHODS A questionnaire with visual analog scales was sent to all our CPAP patients (0 = absolutely unsatisfied, 100 = very satisfied). From the ResMed ResScan program, we obtained the CPAP daily use and air leak values. RESULTS We received 730 answers (70 % of participants); females comprised 22 %. A total of 391 patients had ResMed interfaces, 227 had Respironics, 87 had Fisher & Paykel (F&P), and 25 patients had other interfaces. Interfaces were nasal for 79 %, nasal pillows for 9 %, oronasal for 9 %, and unidentified for 3 % of cases. The mean ± SD satisfaction rate was 68 ± 25. No statistically significant differences were found regarding the type or brand of interface, previous interface experience, or the age or gender of the patient. Users of ResMed interfaces had significantly (p < 0.01) fewer cases of disturbing leaks than did users of Respironics or F&P interfaces (60 vs. 70 and 72 %, respectively). The ResMed Ultra Mirage interface had the fewest cases of disturbing leaks. Values for the measured median leaks were a mean of 5.9 ± 7.2 l/min, and those for the maximum leaks were 39.3 ± 22.2 l/min with no differences between brands. The users of F&P interfaces experienced significantly (p < 0.01) more comfort and used the CPAP device significantly (p < 0.007) more than did users of ResMed or Respironics interfaces (88 % of cases vs. 65 and 57 % and 6.2 ± 2.6 vs. 5.3 ± 2.8 or 5.8 ± 2.8 h/day, respectively). CONCLUSIONS The majority of patients consider the use of the CPAP interface disturbing even though the satisfaction rate is good with no differences between brands.
Collapse
Affiliation(s)
- Adel Bachour
- Sleep Unit, Pulmonary Department, Helsinki University Hospital, P.O. Box 160, Helsinki 00029, Finland.
| | | | | | | |
Collapse
|
33
|
DiFeo N, Meltzer LJ, Beck SE, Karamessinis LR, Cornaglia MA, Traylor J, Samuel J, Gallagher PR, Radcliffe J, Beris H, Menello MK, Marcus CL. Predictors of positive airway pressure therapy adherence in children: a prospective study. J Clin Sleep Med 2012; 8:279-86. [PMID: 22701385 DOI: 10.5664/jcsm.1914] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
STUDY OBJECTIVES Children with obstructive sleep apnea are increasingly being treated with positive airway pressure (PAP), particularly if they have underlying medical conditions. Although PAP is an effective treatment, its use is challenging due to poor adherence. We hypothesized that demographic, psychosocial, and polysomnographic parameters would be related to PAP adherence. We therefore prospectively collected data potentially pertaining to PAP adherence, and correlated it with PAP use. METHODS Fifty-six patients and their parents completed a series of psychosocial questionnaires prior to PAP initiation. Objective adherence data were obtained after 1 and 3 months of PAP use. RESULTS The population was primarily obese; 23% had neurodevelopmental disabilities. PAP adherence varied widely, with PAP being worn 22 ± 8 nights in month-1, but mean use was only 3 ± 3 h/night. The greatest predictor of use was maternal education (p = 0.002 for nights used; p = 0.033 for mean h used/night). Adherence was lower in African American children vs other races (p = 0.021). In the typically developing subgroup, adherence correlated inversely with age. Adherence did not correlate with severity of apnea, pressure levels, or psychosocial parameters other than a correlation between family social support and nights of PAP use in month-3. CONCLUSIONS PAP adherence in children and adolescents is related primarily to family and demographic factors rather than severity of apnea or measures of psychosocial functioning. Further research is needed to determine the relative contributions of maternal education, socioeconomic status and cultural beliefs to PAP adherence in children, in order to develop better adherence programs.
Collapse
Affiliation(s)
- Natalie DiFeo
- Sleep Center, Children’s Hospital of Philadelphia, Philadelphia, PA 19104, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Ebben MR, Oyegbile T, Pollak CP. The efficacy of three different mask styles on a PAP titration night. Sleep Med 2012; 13:645-9. [PMID: 22503941 DOI: 10.1016/j.sleep.2012.02.004] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2011] [Revised: 02/13/2012] [Accepted: 02/14/2012] [Indexed: 01/08/2023]
Abstract
BACKGROUND This study compared the efficacy of three different masks, nasal pillows, nasal masks and full face (oronasal) masks, during a single night of titration with continuous positive airway pressure (CPAP). METHODS Fifty five subjects that included men (n=33) and women (n=22) were randomly assigned to one of three masks and underwent a routine titration with incremental CPAP applied through the different masks. RESULTS CPAP applied through the nasal pillows and nasal mask was equally effective in treating mild, moderate, and severe sleep apnea. However, CPAP applied through the oronasal mask required a significantly higher pressure compared to nasal masks to treat moderately severe (2.8 cm of H(2)O ± 2.1 SD) and severe (6.0 cm of H(2)O ± 3.2 SD) obstructive sleep apnea. CONCLUSION CPAP applied with either nasal mask was effective in treating mild, moderate, and severe sleep apnea. The oronasal mask required significantly higher pressures in subjects with moderate to severe disease. Therefore, when changing from a nasal to an oronasal mask, a repeat titration is required to ensure effective treatment of sleep apnea, especially in patients with moderate to severe disease.
Collapse
Affiliation(s)
- Matthew R Ebben
- Center for Sleep Medicine, Weill Cornell Medical College, New York, NY 10065, USA.
| | | | | |
Collapse
|
35
|
Influence of marital status and employment status on long-term adherence with continuous positive airway pressure in sleep apnea patients. PLoS One 2011; 6:e22503. [PMID: 21857929 PMCID: PMC3157341 DOI: 10.1371/journal.pone.0022503] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2011] [Accepted: 06/23/2011] [Indexed: 11/21/2022] Open
Abstract
Background Long-term adherence is a major issue in patients receiving home continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea-hypopnea syndrome (OSAHS). In a multicenter prospective cohort (the Institut de Recherche en Santé Respiratoire des Pays de la Loire [IRSR] sleep cohort) of consecutive OSAHS patients in whom CPAP had been prescribed for at least 90 days, we studied the impact on long-term treatment adherence of socioeconomic factors, patients and disease characteristics prior to CPAP initiation. Methods and Principal Findings Among 1,141 patients in whom CPAP had been prescribed for an average of 504±251 days (range: 91 to 1035), 674 (59%) were adherent with a mean daily use of CPAP≥4 h (mean: 6.42±1.35 h). Stepwise regression analysis identified 4 independent factors of CPAP adherence including apnea-hypopnea index (AHI) (OR: 1.549, 95%CI 1.163 to 2.062 for AHI≥30 vs. AHI<30; p = 0.003), body mass index (BMI) (OR: 1.786, 95%CI 1.131 to 2.822 for BMI≥25 and <30 kg/m2, p = 0.01; OR: 1.768, 95%CI 1.145–2.731 for BMI≥30 kg/m2, p = 0.01 vs. BMI<25 kg/m2), employment status (OR: 1.414, 95%CI 1.097–1.821 for retired vs. employed; p = 0.007) and marital status (OR: 1.482, 95%CI 1.088–2.019 for married or living as a couple vs. living alone; p = 0.01). Age, gender, Epworth sleepiness scale, depressive syndrome, associated cardiovascular morbidities, educational attainment and occupation category did not influence CPAP adherence. Conclusions Marital status and employment status are independent factors of CPAP adherence in addition to BMI and disease severity. Patients living alone and/or working patients are at greater risk of non-adherence, whereas adherence is higher in married and retired patients. These findings suggest that the social context of daily life should be taken into account in risk screening for CPAP non-adherence. Future interventional studies targeting at-risk patients should be designed to address social motivating factors and work-related barriers to CPAP adherence.
Collapse
|
36
|
|