1
|
Parsa SM, Norozpour F, Elsheikh AH, Kabeel AE. Solar desalination/purification (solar stills, humidification-dehumidification, solar disinfection) in high altitude during COVID19: Insights of gastrointestinal manifestations and systems' mechanism. JOURNAL OF HAZARDOUS MATERIALS ADVANCES 2023; 10:100259. [PMID: 36816517 PMCID: PMC9927827 DOI: 10.1016/j.hazadv.2023.100259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 01/30/2023] [Accepted: 02/13/2023] [Indexed: 02/16/2023]
Abstract
From the starting of the pandemic different transmission routes of the pathogen was brought into the spotlight by researchers from different disciplines. This matter in high-altitudes was more boosted as the main parameters were not exactly realized. In this review we are about to highlight the possibility of consuming contaminated water generated form solar water desalination/disinfection systems in highlands. Three systems including solar still, solar disinfection (which experimented by the authors in 2019 in high altitude) and humidification-dehumidification were consider in this context. Ascribe to the risks of pathogens transmission in solar desalination/disinfection systems where the water resources are heavily polluted in every corner of the world, highlighting the risk of consuming water in high-altitude where there are many other parameters associated with spread of pathogen is of great importance. As it was reported, reliability of solar desalination and solar water disinfections systems against contaminated water by the novel coronavirus remained on the question because the virus can be transmitted by vapor in solar stills due to tiny particle size (60-140 nm) and would not be killed by solar disinfections due to low-temperature of operation <40 °C while for HDH contamination of both water and air by sars-cov-2 could be a concern. Although the SARS-CoV-2 is not a waterborne pathogen, its capability to replicate in stomach and infection of gastrointestinal glandular suggested the potential of transmission via fecal-oral. Eventually, it was concluded that using solar-based water treatment as drinking water in high altitude regions should be cautiously consider and recommendations and considerations are presented. Importantly, this critical review not only about the ongoing pandemic, but it aims is to highlight the importance of produced drinking water by systems for future epidemic/pandemic to prevent spread and entering a pathogen particularly in high-altitude regions via a new routes.
Collapse
Affiliation(s)
- Seyed Masoud Parsa
- Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, Sydney, NSW 2007, Australia
| | - Fatemeh Norozpour
- Department of Environmental Engineering, Faculty of Marine Science and Technology, Islamic Azad University, North Tehran Branch, Tehran, Iran
| | - Ammar H Elsheikh
- Department of Production Engineering and Mechanical Design, Tanta University, Tanta, Egypt
| | - A E Kabeel
- Mechanical Power Engineering Department, Faculty of Engineering, Tanta University, Tanta, Egypt
| |
Collapse
|
2
|
Review of concerned SARS-CoV-2 variants like Alpha (B.1.1.7), Beta (B.1.351), Gamma (P.1), Delta (B.1.617.2), and Omicron (B.1.1.529), as well as novel methods for reducing and inactivating SARS-CoV-2 mutants in wastewater treatment facilities. JOURNAL OF HAZARDOUS MATERIALS ADVANCES 2022. [PMID: 37520798 PMCID: PMC9349052 DOI: 10.1016/j.hazadv.2022.100140] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The coronavirus known as COVID-19, which causes pandemics, is causing a global epidemic at a critical stage today. Furthermore, novel mutations in the SARS-CoV-2 spike protein have been discovered in an entirely new strain, impacting the clinical and epidemiological features of COVID-19. Variants of these viruses can increase the transmission in wastewater, lead to reinfection, and reduce immunity provided by monoclonal antibodies and vaccinations. According to the research, a large quantity of viral RNA was discovered in wastewater, suggesting that wastewater can be a crucial source of epidemiological data and health hazards. The purpose of this paper is to introduce a few basic concepts regarding wastewater surveillance as a starting point for comprehending COVID-19′s epidemiological aspects. Next, the observation of Alpha (B.1.1.7), Beta (B.1.351), Gamma (P.1), Delta (B.1.617.2), and Omicron (B.1.1.529) in wastewater is discussed in detail. Secondly, the essential information for the initial, primary, and final treating sewage in SARS-CoV-2 is introduced. Following that, a thorough examination is provided to highlight the newly developed methods for eradicating SARS-CoV-2 using a combination of solar water disinfection (SODIS) and ultraviolet radiation A (UVA (315-400 nm)), ultraviolet radiation B (UVB (280-315 nm)), and ultraviolet radiation C (UVC (100-280 nm)) processes. SARS-CoV-2 eradication requires high temperatures (above 56°C) and UVC. However, SODIS technologies are based on UVA and operate at cooler temperatures (less than 45°C). Hence, it is not appropriate for sewage treatment (or water consumption) to be conducted using SODIS methods in the current pandemic. Finally, SARS-CoV-2 may be discovered in sewage utilizing the wastewater-based epidemiology (WBE) monitoring method.
Collapse
|
3
|
Parsa SM, Momeni S, Hemmat A, Afrand M. Effectiveness of solar water disinfection in the era of COVID-19 (SARS-CoV-2) pandemic for contaminated water/wastewater treatment considering UV effect and temperature. JOURNAL OF WATER PROCESS ENGINEERING 2021; 43:102224. [PMID: 35592836 PMCID: PMC8285244 DOI: 10.1016/j.jwpe.2021.102224] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 05/26/2021] [Accepted: 07/15/2021] [Indexed: 05/09/2023]
Abstract
Long is the way and hard, that out of COVID-19 leads up to light. The virus is highly contagious and spread rapidly and the number of infections increases exponentially. The colossal number of infections and presence of the novel coronavirus RNA in human wastes (e.g. Excreta/urine) even after the patients recovered and the RT-PCR tests were negative, results in massive load of the viral in water environments. Numerous studies reported the presence of SARS-CoV-2 in wastewater samples. The risk of contaminating water bodies in the regions which suffer from the lack of proper sanitation system and wastewater treatment plants (mostly in developing countries) is higher. Since solar water disinfection (SODIS) is usually used by people in developing countries, there is a concern about using this method during the pandemic. Because the SARS-CoV-2 can be eliminated by high temperature (>56 °C) and UVC wavelength (100-280 nm) while SODIS systems mainly work at lower temperature (<45 °C) and use the available UVA (315-400 nm). Thus, during a situation like the ongoing pandemic using SODIS method for wastewater treatment (or providing drinking water) is not a reliable method. It should be reminded that the main aim of the present study is not just to give insights about the possibilities and risks of using SODIS during the ongoing pandemic but it has broader prospect for any future outbreak/pandemic that results in biological contamination of water bodies. Nevertheless, some experimental studies seem to be necessary by all researchers under conditions similar to developing countries.
Collapse
Affiliation(s)
- Seyed Masoud Parsa
- Department of Energy Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Saba Momeni
- Guilan University of Medical Science, Anzali International Campus, Bandar Anzali, Iran
| | - Ahmadreza Hemmat
- Department of Medicine, Najafabad Branch, Islamic Azad University, Najafabad, Iran
| | - Masoud Afrand
- Department of Mechanical Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran
| |
Collapse
|
4
|
Disinfection Methods and Survival of SARS-CoV-2 in the Environment and Contaminated Materials: A Bibliometric Analysis. SUSTAINABILITY 2020. [DOI: 10.3390/su12187378] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The presence of SARS-CoV-2 in sewage and water resources has been used as an indication for the possible occurrence of the virus among communities and for its potential of transmission among humans through the surrounding environment or water resources. In order to reduce the transmission of SARS-CoV-2, contaminated surfaces should be disinfected frequently by using an effective disinfectant. The present review discusses a bibliometric analysis of the global SARS-CoV-2 research and focuses mainly on reviewing the efficiency of the most traditional disinfection technologies. The disinfection methods reviewed include those for hospitals’ or medical facilities’ wastewater, contaminated surfaces, and contaminated masks. The elimination of the virus based on the concept of sterility assurance level (SAL) is also discussed. In addition, the chemical disinfectants that are currently used, as well as their temporary efficiency, are also reviewed. The different technologies that are globally used for disinfection processes during the COVID-19 pandemic are shown. However, more advanced technologies, such as nanotechnology, might have more potential for higher inactivation effectiveness against SARS-CoV-2.
Collapse
|
5
|
Polo-López MI, Martínez-García A, Abeledo-Lameiro MJ, H Gómez-Couso H, E Ares-Mazás E, Reboredo-Fernández A, Morse TD, Buck L, Lungu K, McGuigan KG, Fernández-Ibáñez P. Microbiological Evaluation of 5 L- and 20 L-Transparent Polypropylene Buckets for Solar Water Disinfection (SODIS). Molecules 2019; 24:molecules24112193. [PMID: 31212699 PMCID: PMC6600371 DOI: 10.3390/molecules24112193] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Revised: 06/04/2019] [Accepted: 06/07/2019] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Solar water disinfection (SODIS) is an appropriate technology for household treatment of drinking water in low-to-middle-income communities, as it is effective, low cost and easy to use. Nevertheless, uptake is low due partially to the burden of using small volume polyethylene terephthalate bottles (1.5-2 L). A major challenge is to develop a low-cost transparent container for disinfecting larger volumes of water. (2) Methods: This study examines the capability of transparent polypropylene (PP) buckets of 5 L- and 20 L- volume as SODIS containers using three waterborne pathogen indicators: Escherichia coli, MS2-phage and Cryptosporidium parvum. (3) Results: Similar inactivation kinetics were observed under natural sunlight for the inactivation of all three organisms in well water using 5 L- and 20 L-buckets compared to 1.5 L-polyethylene-terephthalate (PET) bottles. The PP materials were exposed to natural and accelerated solar ageing (ISO-16474). UV transmission of the 20 L-buckets remained stable and with physical integrity even after the longest ageing periods (9 months or 900 h of natural or artificial solar UV exposure, respectively). The 5 L-buckets were physically degraded and lost significant UV-transmission, due to the thinner wall compared to the 20 L-bucket. (4) Conclusion: This work demonstrates that the 20 L SODIS bucket technology produces excellent bacterial, viral and protozoan inactivation and is obtained using a simple transparent polypropylene bucket fabricated locally at very low cost ($2.90 USD per unit). The increased bucket volume of 20 L allows for a ten-fold increase in treatment batch volume and can thus more easily provide for the drinking water requirements of most households. The use of buckets in households across low to middle income countries is an already accepted practice.
Collapse
Affiliation(s)
| | | | - Maria Jesus Abeledo-Lameiro
- Laboratory of Parasitology, Department of Microbiology and Parasitology, Faculty of Pharmacy, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain.
| | - Hipolito H Gómez-Couso
- Laboratory of Parasitology, Department of Microbiology and Parasitology, Faculty of Pharmacy, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain.
- Institute of Food Research and Analysis, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain.
| | - Elvira E Ares-Mazás
- Laboratory of Parasitology, Department of Microbiology and Parasitology, Faculty of Pharmacy, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain.
| | - Aurora Reboredo-Fernández
- Laboratory of Parasitology, Department of Microbiology and Parasitology, Faculty of Pharmacy, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain.
| | - Tracy D Morse
- Department of Civil and Environmental Engineering, University of Strathclyde, Glasgow G1 1XQ, UK.
| | - Lyndon Buck
- School of Art, Design and Performance, Buckinghamshire New University, High Wycombe HP11 2JZ, UK.
| | - Kingsley Lungu
- Department of Environmental Health, University of Malawi, Malawi.
| | - Kevin G McGuigan
- Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland (RCSI), DO2 YN77 Dublin, Ireland.
| | - Pilar Fernández-Ibáñez
- NIBEC, School of Engineering, Ulster University, Newtownabbey BT37 0QB, Northern Ireland, UK.
| |
Collapse
|
6
|
Pichel N, Vivar M, Fuentes M. The problem of drinking water access: A review of disinfection technologies with an emphasis on solar treatment methods. CHEMOSPHERE 2019; 218:1014-1030. [PMID: 30609481 DOI: 10.1016/j.chemosphere.2018.11.205] [Citation(s) in RCA: 77] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 11/19/2018] [Accepted: 11/29/2018] [Indexed: 05/17/2023]
Abstract
The lack of access to safe drinking water is one of the biggest challenges facing humanity in the 21st century. Despite the collective global effort that has been made, the drinking water sources of at least 2 billion people are faecally contaminated, resulting in more than half a million diarrhoeal deaths each year, with the majority occurring in developing countries. Technologies for the inactivation of pathogenic microorganisms in water are therefore of great significance for human health and well-being. However, conventional technologies to provide drinking water, although effective, present limitations that impede their global application. These treatment methods often have high energy and chemical demands, which limits their application for the prevention of waterborne diseases in the most vulnerable regions. These shortcomings have led to rapid research and development of advanced alternative technologies. One of these alternative methods is solar disinfection, which is recognised by the World Health Organization as one of the most appropriate methods for producing drinkable water in developing countries. This study reviews conventional technologies that are being applied at medium to large scales to purify water and emerging technologies currently in development. In addition, this paper describes the merits, demerits, and limitations of these technologies. Finally, the review focuses on solar disinfection, including a novel technology recently developed in this field.
Collapse
Affiliation(s)
- N Pichel
- IMDEA Water Institute, Alcalá de Henares, 28805, Spain.
| | - M Vivar
- Grupo IDEA, EPS Linares, Universidad de Jaén, Linares 23700, Spain
| | - M Fuentes
- IMDEA Water Institute, Alcalá de Henares, 28805, Spain; Grupo IDEA, EPS Linares, Universidad de Jaén, Linares 23700, Spain
| |
Collapse
|
7
|
Bogdan J, Pławińska-Czarnak J, Zarzyńska J. Nanoparticles of Titanium and Zinc Oxides as Novel Agents in Tumor Treatment: a Review. NANOSCALE RESEARCH LETTERS 2017; 12:225. [PMID: 28351128 PMCID: PMC5368103 DOI: 10.1186/s11671-017-2007-y] [Citation(s) in RCA: 88] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Accepted: 03/17/2017] [Indexed: 05/22/2023]
Abstract
Cancer has become a global problem. On all continents, a great number of people are diagnosed with this disease. In spite of the progress in medical care, cancer still ends fatal for a great number of the ill, either as a result of a late diagnosis or due to inefficiency of therapies. The majority of the tumors are resistant to drugs. Thus, the search for new, more effective therapy methods continues. Recently, nanotechnology has been attributed with big expectations in respect of the cancer fight. That interdisciplinary field of science creates nanomaterials (NMs) and nanoparticles (NPs) that can be applied, e.g., in nanomedicine. NMs and NPs are perceived as very promising in cancer therapy since they can perform as drug carriers, as well as photo- or sonosensitizers (compounds that generate the formation of reactive oxygen species as a result of either electromagnetic radiation excitation with an adequate wavelength or ultrasound activation, respectively). Consequently, two new treatment modalities, the photodynamic therapy (PDT) and the sonodynamic therapy (SDT) have been created. The attachment of ligands or antibodies to NMs or to NPs improve their selective distribution into the targeted organ or cell; hence, the therapy effectiveness can be improved. An important advantage of the targeted tumor treatment is lowering the cyto- and genotoxicity of active substance towards healthy cells. Therefore, both PDT and SDT constitute a valuable alternative to chemo- or radiotherapy. The vital role in cancer eradication is attributed to two inorganic sensitizers in their nanosized scale: titanium dioxide and zinc oxide.
Collapse
Affiliation(s)
- Janusz Bogdan
- Department of Food Hygiene and Public Health Protection, Faculty of Veterinary Medicine, Warsaw University of Life Sciences - SGGW, Nowoursynowska 159, 02-776 Warsaw, Poland
| | - Joanna Pławińska-Czarnak
- Department of Food Hygiene and Public Health Protection, Faculty of Veterinary Medicine, Warsaw University of Life Sciences - SGGW, Nowoursynowska 159, 02-776 Warsaw, Poland
| | - Joanna Zarzyńska
- Department of Food Hygiene and Public Health Protection, Faculty of Veterinary Medicine, Warsaw University of Life Sciences - SGGW, Nowoursynowska 159, 02-776 Warsaw, Poland
| |
Collapse
|
8
|
Abeledo-Lameiro MJ, Reboredo-Fernández A, Polo-López MI, Fernández-Ibáñez P, Ares-Mazás E, Gómez-Couso H. Photocatalytic inactivation of the waterborne protozoan parasite Cryptosporidium parvum using TiO 2 /H 2 O 2 under simulated and natural solar conditions. Catal Today 2017. [DOI: 10.1016/j.cattod.2016.05.046] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Abstract
Availability of safe drinking water, a vital natural resource, is still a distant dream to many around the world, especially in developing countries. Increasing human activity and industrialization have led to a wide range of physical, chemical, and biological pollutants entering water bodies and affecting human lives. Efforts to develop efficient, economical, and technologically sound methods to produce clean water for developing countries have increased worldwide. We focus on solar disinfection, filtration, hybrid filtration methods, treatment of harvested rainwater, herbal water disinfection, and arsenic removal technologies. Simple, yet innovative water treatment devices ranging from use of plant xylem as filters, terafilters, and hand pumps to tippy taps designed indigenously are methods mentioned here. By describing the technical aspects of major water disinfection methods relevant for developing countries on medium to small scales and emphasizing their merits, demerits, economics, and scalability, we highlight the current scenario and pave the way for further research and development and scaling up of these processes. This review focuses on clean drinking water, especially for rural populations in developing countries. It describes various water disinfection techniques that are not only economically viable and energy efficient but also employ simple methodologies that are effective in reducing the physical, chemical, and biological pollutants found in drinking water to acceptable limits.
Collapse
Affiliation(s)
- Aniruddha B Pandit
- Department of Chemical Engineering Department, Institute of Chemical Technology, Matunga, Mumbai 400019, India;
| | | |
Collapse
|
10
|
Al-Gheethi AA, Mohamed RMSR, Efaq AN, Amir Hashim MK. Reduction of microbial risk associated with greywater by disinfection processes for irrigation. JOURNAL OF WATER AND HEALTH 2016; 14:379-398. [PMID: 27280605 DOI: 10.2166/wh.2015.220] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Greywater is one of the most important alternative sources for irrigation in arid and semi-arid countries. However, the health risk associated with the microbial contents of these waters limits their utilization. Many techniques have been developed and used to generate a high microbiological quality of greywater. The main problem in the treatment of greywater lies in the nature of pathogenic bacteria in terms of their ability to survive during/after the treatment process. The present review focused on the health risk associated with the presence of pathogenic bacteria in greywater and the treatment technologies used for the disinfection processes.
Collapse
Affiliation(s)
- A A Al-Gheethi
- Faculty of Civil and Environment Engineering, UTHM, Batu Pahat, Johor, Malaysia E-mail:
| | - R M S Radin Mohamed
- Faculty of Civil and Environment Engineering, UTHM, Batu Pahat, Johor, Malaysia E-mail:
| | - A N Efaq
- School of Industrial Technology, Universiti Sains Malaysia (USM), Penang, Malaysia
| | - M K Amir Hashim
- Faculty of Civil and Environment Engineering, UTHM, Batu Pahat, Johor, Malaysia E-mail:
| |
Collapse
|
11
|
Speeding up the solar water disinfection process (SODIS) against Cryptosporidium parvum by using 2.5l static solar reactors fitted with compound parabolic concentrators (CPCs). Acta Trop 2012; 124:235-42. [PMID: 22944729 DOI: 10.1016/j.actatropica.2012.08.018] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2012] [Revised: 08/11/2012] [Accepted: 08/24/2012] [Indexed: 11/22/2022]
Abstract
Water samples of 0, 5, and 100 nephelometric turbidity units (NTU) spiked with Cryptosporidium parvum oocysts were exposed to natural sunlight in 2.5l static borosilicate solar reactors fitted with two different compound parabolic concentrators (CPCs), CPC1 and CPC1.89, with concentration factors of the solar radiation of 1 and 1.89, respectively. The global oocyst viability was calculated by the evaluation of the inclusion/exclusion of the fluorogenic vital dye propidium iodide and the spontaneous excystation. Thus, the initial global oocyst viability of the C. parvum isolate used was 95.3 ± 1.6%. Using the solar reactors fitted with CPC1, the global viability of oocysts after 12h of exposure was zero in the most turbid water samples (100 NTU) and almost zero in the other water samples (0.3 ± 0.0% for 0 NTU and 0.5 ± 0.2% for 5 NTU). Employing the solar reactors fitted with CPC1.89, after 10h exposure, the global oocyst viability was zero in the non-turbid water samples (0 NTU), and it was almost zero in the 5 NTU water samples after 8h of exposure (0.5 ± 0.5%). In the most turbid water samples (100 NTU), the global viability was 1.9 ± 0.6% after 10 and 12h of exposure. In conclusion, the use of these 2.5l static solar reactors fitted with CPCs significantly improved the efficacy of the SODIS technique as these systems shorten the exposure times to solar radiation, and also minimize the negative effects of turbidity. This technology therefore represents a good alternative method for improving the microbiological quality of household drinking water in developing countries.
Collapse
|
12
|
Bichai F, Polo-López MI, Fernández Ibañez P. Solar disinfection of wastewater to reduce contamination of lettuce crops by Escherichia coli in reclaimed water irrigation. WATER RESEARCH 2012; 46:6040-50. [PMID: 22981489 DOI: 10.1016/j.watres.2012.08.024] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2012] [Revised: 08/16/2012] [Accepted: 08/17/2012] [Indexed: 06/01/2023]
Abstract
Low-cost disinfection methods to allow safe use of recycled wastewater for irrigation can have important beneficial implications in the developing world. This study aims to assess the efficiency of solar disinfection to reduce microbial contamination of lettuce crops when solar-treated wastewater effluents are used for irrigation. The irrigation study was designed as a complete experimental loop, including (i) the production of irrigation water through solar disinfection of real municipal wastewater treatment plant effluents (WWTPE), (ii) the watering of cultivated lettuce crops at the end of solar treatment, and (iii) the detection of microbial contamination on the irrigated crops 24 h after irrigation. Solar disinfection was performed using two types of reactors: (i) 20-L batch borosilicate glass reactors equipped with CPC to optimize solar irradiation, and (ii) 1.5-L PET bottles, i.e. the traditional SODIS recipients commonly used for disinfection of drinking water in developing communities. Both solar and H(2)O(2)-aided solar disinfection processes were tested during ≤5 h exposure of WWTPE, and Escherichia coli inactivation was analysed. A presence/absence detection method was developed to analyse lettuce leaves sampled 24 h after watering for the detection of E. coli. Results of inactivation assays show that solar disinfection processes can bring down bacterial concentrations of >10(3)-10(4)E. coli CFU mL(-1) in real WWTPE to <2 CFU/mL (detection limit). The absence of E. coli on most lettuce samples after irrigation with solar-disinfected effluents (26 negative samples/28) confirmed an improved safety of irrigation practices due to solar treatment, while crops irrigated with raw WWTPE showed contamination.
Collapse
Affiliation(s)
- Françoise Bichai
- Plataforma Solar de Almería-CIEMAT, Carretera Senés km 4, 04200 Tabernas (Almería), Spain.
| | | | | |
Collapse
|
13
|
McGuigan KG, Conroy RM, Mosler HJ, du Preez M, Ubomba-Jaswa E, Fernandez-Ibañez P. Solar water disinfection (SODIS): a review from bench-top to roof-top. JOURNAL OF HAZARDOUS MATERIALS 2012; 235-236:29-46. [PMID: 22906844 DOI: 10.1016/j.jhazmat.2012.07.053] [Citation(s) in RCA: 180] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2012] [Revised: 07/27/2012] [Accepted: 07/28/2012] [Indexed: 05/12/2023]
Abstract
Solar water disinfection (SODIS) has been known for more than 30 years. The technique consists of placing water into transparent plastic or glass containers (normally 2L PET beverage bottles) which are then exposed to the sun. Exposure times vary from 6 to depending on the intensity of sunlight and sensitivity of the pathogens. Its germicidal effect is based on the combined effect of thermal heating of solar light and UV radiation. It has been repeatedly shown to be effective for eliminating microbial pathogens and reduce diarrhoeal morbidity including cholera. Since 1980 much research has been carried out to investigate the mechanisms of solar radiation induced cell death in water and possible enhancement technologies to make it faster and safer. Since SODIS is simple to use and inexpensive, the method has spread throughout the developing world and is in daily use in more than 50 countries in Asia, Latin America, and Africa. More than 5 million people disinfect their drinking water with the solar disinfection (SODIS) technique. This review attempts to revise all relevant knowledge about solar disinfection from microbiological issues, laboratory research, solar testing, up to and including real application studies, limitations, factors influencing adoption of the technique and health impact.
Collapse
|
14
|
Fisher MB, Iriarte M, Nelson KL. Solar water disinfection (SODIS) of Escherichia coli, Enterococcus spp., and MS2 coliphage: effects of additives and alternative container materials. WATER RESEARCH 2012; 46:1745-1754. [PMID: 22257930 DOI: 10.1016/j.watres.2011.12.048] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2011] [Revised: 12/20/2011] [Accepted: 12/21/2011] [Indexed: 05/31/2023]
Abstract
The use of alternative container materials and added oxidants accelerated the inactivation of MS2 coliphage and Escherichia coli and Enterococcus spp. bacteria during solar water disinfection (SODIS) trials. Specifically, bottles made from polypropylene copolymer (PPCO), a partially UVB-transparent plastic, resulted in three-log inactivation of these organisms in approximately half the time required for disinfection in bottles made from PET, polycarbonate, or Tritan(®), which absorb most UVB light. Furthermore, the addition of 125 mg/L sodium percarbonate in combination with either citric acid or copper plus ascorbate tended to accelerate inactivation by factors of 1.4-19. Finally, it was observed that the inactivation of E. coli and enterococci derived from local wastewater was far slower than the inactivation of laboratory-cultured E. coli and Enterococcus spp., while the inactivation of MS2 was slowest of all. These results highlight the importance of UVB in SODIS under certain conditions, and also the greater sunlight resistance of some viruses and of bacteria of fecal origin, as compared to the laboratory-cultured bacteria commonly used to model their inactivation. Furthermore, this study illustrates promising new avenues for accelerating the inactivation of bacteria and viruses by solar disinfection.
Collapse
Affiliation(s)
- Michael B Fisher
- Department of Civil and Environmental Engineering, University of California, Berkeley, CA 94720-1710, USA.
| | | | | |
Collapse
|
15
|
Fontán-Sainz M, Gómez-Couso H, Fernández-Ibáñez P, Ares-Mazás E. Evaluation of the solar water disinfection process (SODIS) against Cryptosporidium parvum using a 25-L static solar reactor fitted with a compound parabolic collector (CPC). Am J Trop Med Hyg 2012; 86:223-8. [PMID: 22302852 PMCID: PMC3269405 DOI: 10.4269/ajtmh.2012.11-0325] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2011] [Accepted: 07/10/2011] [Indexed: 11/07/2022] Open
Abstract
Water samples of 0, 5, and 30 nephelometric turbidity units (NTU) spiked with Cryptosporidium parvum oocysts were exposed to natural sunlight using a 25-L static solar reactor fitted with a compound parabolic collector (CPC). The global oocyst viability was calculated by the evaluation of the inclusion/exclusion of the fluorogenic vital dye propidium iodide and the spontaneous excystation. After an exposure time of 8 hours, the global oocyst viabilities were 21.8 ± 3.1%, 31.3 ± 12.9%, and 45.0 ± 10.0% for turbidity levels of 0, 5, and 30 NTU, respectively, and these values were significantly lower (P < 0.05) that the initial global viability of the isolate (92.1 ± 0.9%). The 25-L static solar reactor that was evaluated can be an alternative system to the conventional solar water disinfection process for improving the microbiological quality of drinking water on a household level, and moreover, it enables treatment of larger volumes of water (> 10 times).
Collapse
Affiliation(s)
- María Fontán-Sainz
- Laboratorio de Parasitología, Departamento de Microbiología y Parasitología, Facultad de Farmacia, Universidad de Santiago de Compostela, Santiago de Compostela, A Coruña, Spain.
| | | | | | | |
Collapse
|
16
|
Dunlop PSM, Ciavola M, Rizzo L, Byrne JA. Inactivation and injury assessment of Escherichia coli during solar and photocatalytic disinfection in LDPE bags. CHEMOSPHERE 2011; 85:1160-1166. [PMID: 21982840 DOI: 10.1016/j.chemosphere.2011.09.006] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Revised: 09/07/2011] [Accepted: 09/08/2011] [Indexed: 05/31/2023]
Abstract
Solar disinfection (SODIS) of Escherichia coli suspensions in low-density polyethylene bag reactors was investigated as a low-cost disinfection method suitable for application in developing countries. The efficiency of a range of SODIS reactor configurations was examined (single skin (SS), double skin, black-backed single skin, silver-backed single skin (SBSS) and composite-backed single skin) using E. coli suspended in model and real surface water. Titanium dioxide was added to the reactors to improve the efficiency of the SODIS process. The effect of turbidity was also assessed. In addition to viable counts, E. coli injury was characterised through spread-plate analysis using selective and non-selective media. The optimal reactor configuration was determined to be the SBSS bag (t(50)=9.0min) demonstrating the importance of UVA photons, as opposed to infrared in the SODIS disinfection mechanism. Complete inactivation (6.5-log) was achieved in the presence of turbidity (50NTU) using the SBSS bag within 180min simulated solar exposure. The addition of titanium dioxide (0.025gL(-1)) significantly enhanced E. coli inactivation in the SS reactor, with 6-log inactivation observed within 90min simulated solar exposure. During the early stages of both SODIS and photocatalytic disinfection, injured E. coli were detected; however, irreversible injury was caused and re-growth was not observed. Experiments under solar conditions were undertaken with total inactivation (6.5-log) observed in the SS reactor within 240min, incomplete inactivation (4-log) was observed in SODIS bottles exposed to the same solar conditions.
Collapse
Affiliation(s)
- P S M Dunlop
- Photocatalysis Research Group, Nanotechnology and Integrated BioEngineering Centre, University of Ulster, Northern Ireland, United Kingdom
| | | | | | | |
Collapse
|
17
|
|
18
|
Gómez-Couso H, Fontán-Sainz M, Ares-Mazás E. Thermal contribution to the inactivation of Cryptosporidium in plastic bottles during solar water disinfection procedures. Am J Trop Med Hyg 2010; 82:35-9. [PMID: 20064992 DOI: 10.4269/ajtmh.2010.09-0284] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
To determine the thermal contribution, independent of ultraviolet radiation, on the inactivation of Cryptosporidium parvum during solar water disinfection procedures (SODIS), oocysts were exposed for 4, 8, and 12 hours to temperatures recorded in polyethylene terephthalate bottles in previous SODIS studies carried out under field conditions. Inclusion/exclusion of the fluorogenic vital dye propidium iodide, spontaneous excystation, and infectivity studies were used to determine the inactivation of oocysts. There was a significant increase in the percentage of oocysts that took up propidium iodide and in the number of oocysts that excysted spontaneously. There was also a significant decrease in the intensity of infection elicited in suckling mice at the end of all exposure times. The results of the study demonstrate the importance of temperature in the inactivation of C. parvum oocysts during application of SODIS under natural conditions.
Collapse
Affiliation(s)
- Hipólito Gómez-Couso
- Laboratorio de Parasitología, Departamento de Microbiología y Parasitología, Facultad de Farmacia, Universidad de Santiago de Compostela, Santiago de Compostela, A Coruña, Spain
| | | | | |
Collapse
|