1
|
The impact of bolus versus continuous infusion of intravenous ketamine on bispectral index variations and desflurane administration during major surgery: The KETABIS study. Eur J Anaesthesiol 2021; 38:1168-1179. [PMID: 34474441 DOI: 10.1097/eja.0000000000001588] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Although ketamine, a NMDA-receptor antagonist, tends to increase the bispectral index (BIS), it remains a widely used analgesic whenever administered in low doses during major surgery. OBJECTIVE The objective of this study was to compare the impact of intravenous ketamine (given either as a continuous infusion or as a bolus) on BIS and to compare desflurane administration and postoperative outcomes between the groups. DESIGN Prospective, randomised, parallel-group, open-label study. SETTING University hospital, operating room. PARTICIPANTS Fifty patients, scheduled for major abdominal surgery. INTERVENTIONS AND MAIN OUTCOMES MEASURES Patients were randomised into two groups: ketamine by intravenous continuous infusion - group (KI) and ketamine by i.v. bolus - group (KB). In the KI group, ketamine at a rate of 0.25 mg kg-1 h-1 was commenced at skin incision (T0) and maintained at this rate for the duration of surgery. In group KB, a ketamine bolus of 0.25 mg kg-1was administered at T0 and repeated every hour. The difference in BIS between the groups was compared from T0 onwards. The amount of desflurane administered to keep BIS within the usual recommended range (40-60) was compared, as were the doses of phenylephrine and remifentanil. Postoperative pain and recovery outcomes were also assessed. RESULTS After T0, the BIS increased significantly from baseline in group KB compared with group KI: the rise in BIS was 20 ± 8 vs. 11 ± 6, respectively (P = 0.0001). The between-group mean difference (95% confidence interval (CI), was 9 (5 to 13). In group KB, desflurane administration significantly increased for the first 15 min after T0: 6.3 ± 1.8 vs. 3.8 ± 1.3 ml (P < 0.0001) with a mean intergroup group difference (95% CI) of 2.4 (1.5 to 3.4) ml. There was no difference in desflurane administration when considering the full hour from T0 to T60 min: 16 ± 9 vs. 15 ± 5 ml (P = 0.63) with a mean intergroup difference (95% CI) of 1 (-3 to 5) ml. After surgery, pain scores, opioid consumption, incidence of nausea and vomiting and recovery scores were similar between groups. CONCLUSION Compared with a continuous ketamine infusion, a ketamine bolus significantly increased the BIS after T0. In order to keep the BIS below 60, significantly more desflurane was administered from T0 to T15 min in group KB. To prevent such higher desflurane administration and its related atmospheric pollution, our results suggest administering intra-operative intravenous ketamine as an infusion rather than a bolus. TRIAL REGISTRATION Clinicaltrials.gov registration identifier: NCT03781635.
Collapse
|
2
|
|
3
|
García PS, Kreuzer M, Hight D, Sleigh JW. Effects of noxious stimulation on the electroencephalogram during general anaesthesia: a narrative review and approach to analgesic titration. Br J Anaesth 2021; 126:445-457. [PMID: 33461725 DOI: 10.1016/j.bja.2020.10.036] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 10/01/2020] [Accepted: 10/24/2020] [Indexed: 01/10/2023] Open
Abstract
Electroencephalographic (EEG) activity is used to monitor the neurophysiology of the brain, which is a target organ of general anaesthesia. Besides its use in evaluating hypnotic states, neurophysiologic reactions to noxious stimulation can also be observed in the EEG. Recognising and understanding these responses could help optimise intraoperative analgesic management. This review describes three types of changes in the EEG induced by noxious stimulation when the patient is under general anaesthesia: (1) beta arousal, (2) (paradoxical) delta arousal, and (3) alpha dropout. Beta arousal is an increase in EEG power in the beta-frequency band (12-25 Hz) in response to noxious stimulation, especially at lower doses of anaesthesia drugs in the absence of opioids. It is usually indicative of a cortical depolarisation and increased cortical activity. At higher concentrations of anaesthetic drug, and with insufficient opioids, delta arousal (increased power in the delta band [0.5-4 Hz]) and alpha dropout (decreased alpha power [8-12 Hz]) are associated with noxious stimuli. The mechanisms of delta arousal are not well understood, but the midbrain reticular formation seems to play a role. Alpha dropout may indicate a return of thalamocortical communication, from an idling mode to an operational mode. Each of these EEG changes reflect an incomplete modulation of pain signals and can be mitigated by administration of opioid or the use of regional anaesthesia techniques. Future studies should evaluate whether titrating analgesic drugs in response to these EEG signals reduces postoperative pain and influences other postoperative outcomes, including the potential development of chronic pain.
Collapse
Affiliation(s)
- Paul S García
- Department of Anesthesiology, Columbia University, New York, NY, USA.
| | - Matthias Kreuzer
- Department of Anesthesiology and Intensive Care, Technical University of Munich School of Medicine, Munich, Germany
| | - Darren Hight
- Department of Anaesthesiology, Waikato Clinical School, University of Auckland, Hamilton, New Zealand; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - James W Sleigh
- Department of Anaesthesiology, Waikato Clinical School, University of Auckland, Hamilton, New Zealand
| |
Collapse
|
4
|
Jung K, Park MH, Kim DK, Kim BJ. Prediction of Postoperative Pain and Opioid Consumption Using Intraoperative Surgical Pleth Index After Surgical Incision: An Observational Study. J Pain Res 2020; 13:2815-2824. [PMID: 33192089 PMCID: PMC7654540 DOI: 10.2147/jpr.s264101] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 09/29/2020] [Indexed: 11/23/2022] Open
Abstract
Background We evaluated whether the surgical pleth index (SPI) following surgical incision was related to postoperative pain and opioid consumption. Methods This prospective observational study was performed in 50 patients undergoing laparotomy under sevoflurane-based general anesthesia. We recorded the highest SPI during surgical incision. The postoperative pain with a numerical rating scale (NRS) and opioid consumption during postoperative 24 h were compared in patients who showed SPI over 50 (Group H) or 20–50 (Group L). The relationship between postoperative opioid consumption and SPI values (pre-incision, post-incision SPI value, change of SPI value, and post-incision SPI minus pre-incision SPI) was evaluated using receiver-operating characteristic analysis. Results The mean of the highest SPI value during surgical incision was 56 (SD, 12; range, 26–85). Twenty-nine (63%) patients were included in Group H and 17 (37%) patients in Group L. There was a significant difference in NRS during recovery room stay and on postoperative 24 h in two groups (5 [5, 6] vs 7 [6, 8], p=0.007 and 3.5 [3, 5] vs 5 [5,6], p=0.006, Group L vs Group H). Group H used higher fentanyl via patient control analgesia during postoperative 24 h (573 (253) µg vs 817 (305) µg, p=0.008). A change of pre-incision and post-incision SPI value of 23, which showed the highest sensitivity (67%) and specificity (68%), was defined post hoc as the cut-off for fentanyl consumption during postoperative 24 h ≥1000 µg. Conclusion Our finding suggests that the SPI response to nociceptive stimuli during surgery is closely related to the degree of patient postoperative pain and opioid requirements. This information may be used to provide proper intraoperative analgesia and individual postoperative pain management.
Collapse
Affiliation(s)
- Kangha Jung
- Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Mi Hye Park
- Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Duk Kyung Kim
- Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Byung Jun Kim
- Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| |
Collapse
|
5
|
Insomnia may increase anesthetic requirement. J Clin Anesth 2016; 34:367-72. [DOI: 10.1016/j.jclinane.2016.05.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Revised: 05/04/2016] [Accepted: 05/04/2016] [Indexed: 11/19/2022]
|
6
|
Robleda G, Roche-Campo F, Membrilla-Martínez L, Fernández-Lucio A, Villamor-Vázquez M, Merten A, Gich I, Mancebo J, Català-Puigbó E, Baños J. Evaluación del dolor durante la movilización y la aspiración endotraqueal en pacientes críticos. Med Intensiva 2016; 40:96-104. [DOI: 10.1016/j.medin.2015.03.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2014] [Revised: 03/11/2015] [Accepted: 03/14/2015] [Indexed: 12/15/2022]
|
7
|
Li YH, He R, Ruan JG. Effect of hepatic function on the EC50 of midazolam and the BIS50 at the time of loss of consciousness. J Zhejiang Univ Sci B 2015; 15:743-9. [PMID: 25091993 DOI: 10.1631/jzus.b1300242] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To explore the effect of hepatic function on loss of consciousness (LOC) and bispectral index (BIS) during sedation with midazolam (MDZ). METHODS Forty-five patients were assigned to three groups according to their liver function. Thirty of these patients with diagnoses of cholelithiasis were scheduled laparoscopic cholecystectomy, including 15 patients with normal liver function (normal group), and 15 patients with moderately abnormal liver function based on the results of ultrasonic diagnosis of a moderately fatty liver and elevated alanine transaminase levels of less than three times normal (moderate group). The other 15 patients with end-stage liver disease (severe group) underwent liver transplantation. Each patient was administered MDZ by way of target-controlled infusion to increase the concentration gradually. At the time of LOC, the BIS was recorded and a blood sample was withdrawn for measurement of the concentration of MDZ. The concentration of MDZ (EC50) and the BIS value (BIS50) at which 50% of patients lose consciousness were calculated using logistic regression. RESULTS At the time of LOC, the EC50 of MDZ and the BIS50 were similar in the normal and moderate groups (P>0.05). LOC occurred at a lower EC50 of MDZ and at a higher BIS50 in the severe group, compared with the normal and moderate groups (P<0.01). CONCLUSIONS Patients with end-stage liver disease were more sensitive to MDZ and this affected the prediction of their time of LOC following MDZ administration. There were no changes in response in patients with moderately abnormal hepatic function.
Collapse
Affiliation(s)
- Yu-hong Li
- Department of Anesthesiology, Shaoxing People's Hospital, Shaoxing 312000, China; Department of Anesthesiology, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310003, China
| | | | | |
Collapse
|
8
|
Ghaffaripour S, Khosravi MB, Rahimi A, Sahmedini MA, Chohedri A, Mahmoudi H, Kazemi MR. The effects of Aminophylline on clinical recovery and bispectral index in patients anesthetized with total intravenous anaesthesia. Pak J Med Sci 2015; 30:1351-5. [PMID: 25674137 PMCID: PMC4320729 DOI: 10.12669/pjms.306.5853] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Revised: 09/10/2014] [Accepted: 09/15/2014] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE Aminophylline, which is clinically used as a bronchodilator, antagonizes the action of adenosine, so it can be used to shorten the recovery time after general anesthesia. Therefore, we wanted to test the hypothesis that the administration of aminophylline leads to an increase in bispectral index (BIS) and clinical recovery in patients anesthetized with total intravenous anesthesia (TIVA). Methods : Ninety two patients who were scheduled for elective inguinal herniorrhaphy were enrolled in this study. All patients were premedicated with midazolam and morphine. Anesthesia was induced with propofol 2.5 mg /kg and remifentanil 2.5 µg/kg without muscle relaxant. For maintenance of anesthesia we used propofol 100µg/kg/min, remifentanil 0.2µg/kg/min and 100% oxygen with stable BIS readings in the range 40-60. After skin closure, aminophylline 4mg/ kg was given to Group A and an equivalent volume of normal saline to Group P. BIS values, heart rate, blood pressure, oxygen saturation and End tidal CO2(ETco2) were determined. Time to eye opening, extubation time and response to command were measured. Results : There were no significant differences in SpO2, ETco2 and anesthesia time. Heart rate and systolic blood pressure were found to be statistically higher (p<0.001) in Group A. Time to eye opening, hand grip and extubation were significantly shorter (p<0.001) in Group A. Bispectral index scores were significantly higher in group A. CONCLUSIONS Injection of aminophylline at emergence time led to significant increase in BIS and shortening recovery time from anesthesia.
Collapse
Affiliation(s)
- Sina Ghaffaripour
- Sina Ghaffaripour, Associate Professor, Shiraz Anesthesiology and Critical Care Research Center, Department of Anesthesiology, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Bagher Khosravi
- Mohammad Bagher Khosravi, Associate Professor, Shiraz Anesthesiology and Critical Care Research Center, Department of Anesthesiology, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Ashkan Rahimi
- Ashkan Rahimi, Anesthesiologist, Shiraz Anesthesiology and Critical Care Research Center, Department of Anesthesiology, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Ali Sahmedini
- Mohammad Ali Sahmedini, Associate Professor, Shiraz Anesthesiology and Critical Care Research Center, Department of Anesthesiology, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Abdolhamid Chohedri
- Abdolhamid Chohedri, Associate Professor, Shiraz Anesthesiology and Critical Care Research Center, Department of Anesthesiology, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Hilda Mahmoudi
- Hilda Mahmoudi, Community Medicine and Public Health Specialist. Shiraz Anesthesiology and Critical Care Research Center, Department of Anesthesiology, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Reza Kazemi
- Mohammad Reza Kazemi, Anesthesiologist, Shiraz Anesthesiology and Critical Care Research Center, Department of Anesthesiology, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
9
|
The use of the bispectral index in the detection of pain in mechanically ventilated adults in the intensive care unit: a review of the literature. Pain Res Manag 2014; 20:e33-7. [PMID: 25050877 PMCID: PMC4325898 DOI: 10.1155/2015/981419] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
The bispectral index is a technique that involves assessing brain activity (through electroencephalography as well as electromyography), and has been proposed to be useful for the detection of pain among patients who are unable to communicate verbally. This review aimed to clarify whether the bispectral index is an appropriate tool to assess pain in the intensive care unit. BACKGROUND: Pain assessment is an immense challenge for clinicians, especially in the context of the intensive care unit, where the patient is often unable to communicate verbally. Several methods of pain assessment have been proposed to assess pain in this environment. These include both behavioural observation scales and evaluation of physiological measurements such as heart rate and blood pressure. Although numerous validation studies pertaining to behavioural observation scales have been published, several limitations associated with using these measures for pain assessment remain. Over the past few years, researchers have been interested in the use of the bispectral index monitoring system as a proxy for the evaluation of encephalography readings to assess the level of anesthesia and, potentially, analgesia. OBJECTIVES: To synthesize the main studies exploring the use of the bispectral index monitoring system for pain assessment, to guide future research in adults under sedation in the intensive care unit. METHOD: The EMBASE, Medline, CINAHL and PsycINFO databases were searched for studies published between 1996 and 2013 that evaluated the use of the bispectral index in assessing pain. RESULTS: Most studies conclude that nociceptive stimulation causes a significant increase in the bispectral index and revealed the importance of controlling certain confounding variables such as the level of sedation. DISCUSSION: Further studies are needed to clearly demonstrate the relationship between nociceptive stimuli and the bispectral index, as well as the specificity of the bispectral index in detecting pain.
Collapse
|
10
|
Abstract
Applying scalp sensors in the operating theater, intensive care, or resuscitation scenarios to detect and monitor brain function is achievable, practical, and affordable. The modalities are complex and the output of the monitor needs careful interpretation. The monitor may have technical problems, and a single reading must be considered with caution. These monitors may have a use for monitoring trends in specific situations, but evidence does not support their widespread use. Nevertheless, research should continue to investigate their role. Future techniques and treatments may show that these monitors can monitor brain function and prevent harm.
Collapse
Affiliation(s)
- Michael Sury
- Department of Anaesthesia, Great Ormond Street Hospital, Great Ormond Street, London WC1N 3JH, UK.
| |
Collapse
|
11
|
Changes in the Bispectral Index in Response to Experimental Noxious Stimuli in Adults under General Anesthesia. ISRN PAIN 2013; 2013:583920. [PMID: 27335878 PMCID: PMC4893395 DOI: 10.1155/2013/583920] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2013] [Accepted: 06/25/2013] [Indexed: 11/18/2022]
Abstract
Objective. Pain assessment is a major challenge in nonverbal patients in the intensive care unit (ICU). Recent studies suggest a relationship between the Bispectral Index (BIS) and nociceptive stimuli. This study was designed to examine changes in BIS in response to experimental noxious stimuli. Methods. Thirty participants under general anesthesia were in this quasiexperimental, within subject, pre- and poststudy. In the operating room (OR), BIS was monitored during moderate and severe noxious stimuli, induced by a thermal probe on the participants' forearm, after induction of general anesthesia, prior to surgery. Results. Significant increases in BIS occurred during moderate (increase from 35.00 to 40.00, P = 0.003) and severe noxious stimuli (increase from 37.67 to 40.00, P = 0.007). ROC showed a sensitivity (Se) of 40.0% and a specificity (Sp) of 73.3% at a BIS value > 45, in distinguishing a moderate from a severe noxious stimuli. Conclusion. BIS increased in response to moderate and severe noxious stimuli. The Se and Sp of the BIS did not support the use of the BIS for distinction of different pain intensities in the context of deep sedation in the OR. However, the results justify further studies in more lightly sedated patients such as those in the ICU.
Collapse
|
12
|
Santuzzi CH, Neto HDAF, Pires JGP, Gonçalves WLS, Gouvea SA, Abreu GR. High-frequency transcutaneous electrical nerve stimulation reduces pain and cardio-respiratory parameters in an animal model of acute pain: participation of peripheral serotonin. Physiother Theory Pract 2013; 29:630-8. [PMID: 23477354 DOI: 10.3109/09593985.2013.774451] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The objective of this study was to investigate the effect of high-frequency transcutaneous electrical nerve stimulation (HF-TENS) in antihyperalgesia, assessed through changes of sciatic nerve activity and its effects on cardiorespiratory parameters, using formalin-induced nociception in anesthetized rats. The animals were divided into formalin (FORM) and HF-TENS groups. All rats received injections of 5% formalin (50 μl, right hind-paw). The sciatic nerve activity and cardiopulmonary parameters (mean arterial pressure, heart rate, and respiratory frequency) were measured, and then the serum levels of serotonin (5-HT) were determined by an enzyme-linked immunosorbent assay kit. The formalin injection was able to increase the sciatic nerve activity, heart rate, and respiratory frequency. The treatment with HF-TENS significantly reduced the sciatic nerve activity and respiratory frequency 20 minutes after formalin injection and was able to increase serum 5-HT. Furthermore, when comparing the groups, reductions in the mean arterial pressure, heart rate, respiratory frequency, and sciatic nerve activity were shown at different times. Thus, we concluded that HF-TENS was capable of inducing analgesia, which was most likely related to increased serotonin release. Moreover, we demonstrated that TENS was able to block the adverse cardiovascular and respiratory changes induced by pain. Further neurophysiological studies are necessary to clarify the intrinsic mechanisms underlying HF-TENS-induced analgesia.
Collapse
Affiliation(s)
- Cíntia Helena Santuzzi
- Programa de Pós-Graduação em Ciências Fisiológicas, Health Sciences Center , Federal University of Espirito Santo , Vitória , Brazil
| | | | | | | | | | | |
Collapse
|
13
|
Khafagy HF, Ebied RS, Osman ES, Ali MZ, Samhan YM. Perioperative effects of various anesthetic adjuvants with TIVA guided by bispectral index. Korean J Anesthesiol 2012; 63:113-9. [PMID: 22949977 PMCID: PMC3427802 DOI: 10.4097/kjae.2012.63.2.113] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2011] [Revised: 03/09/2012] [Accepted: 03/13/2012] [Indexed: 11/17/2022] Open
Abstract
Background This prospective, randomized, double blinded, controlled study was designed to compare effects of intravenous co-administration of clonidine, magnesium, or ketamine on anesthetic consumption, intraoperative hemodynamics, postoperative analgesia and recovery indices during Bispectral Index (BIS) guided total intravenous anesthesia (TIVA). Methods After ethical committee approval and written informed consent, 120 adult patients ASA I and II scheduled for open cholecystectomy were randomly assigned to one of 4 equal groups. Group CL received clonidine 3 µg/kg and maintained by 2 µg/kg/h. Group MG received magnesium sulphate 50 mg/kg and maintained by 8 mg/kg/h. Group KET received racemic ketamine 0.4 mg/kg and maintained by 0.2 mg/kg/h. Control group (CT) received the same volume of isotonic saline. Anesthesia was induced and maintained by fentanyl, propofol and rocuronium. Propofol infusion was adjusted to keep the BIS value between 45-55. Intraoperative hemodynamics, induction time, anesthetic consumption, recovery indices, and PACU discharge were recorded. Results Induction time, propofol requirements for induction and maintenance of anesthesia, intraoperative fentanyl and hemodynamic values were significantly lower with Groups CL and MG compared to Groups KET and CT (P < 0.05). Patients in Group MG showed significantly lower muscle relaxant consumption, delayed recovery and PACU discharge than other groups (P < 0.05). First, analgesic requirement was significantly longer and total postoperative analgesic consumption was significantly lower in the adjuvant groups versus Group CT (P < 0.05). Conclusions Clonidine, magnesium, and ketamine can be useful adjuvant agents to BIS-guided TIVA. Pharmacokinetic studies of such drug combinations were recommended to investigate their interaction.
Collapse
Affiliation(s)
- Hanan F Khafagy
- Department of Anesthesiology, Theodor Bilharz Research Institute, Ministry of High Education and Scientific Research, Giza, Egypt
| | | | | | | | | |
Collapse
|
14
|
Belda E, Laredo FG, Lucas X, Agut A, Escobar M, Soler M. The effects of atracurium on bispectral index (BIS) values in dogs anaesthetized with isoflurane. Vet J 2012; 192:189-92. [DOI: 10.1016/j.tvjl.2011.05.021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2010] [Revised: 05/23/2011] [Accepted: 05/25/2011] [Indexed: 10/17/2022]
|
15
|
Abstract
PURPOSE OF REVIEW We critically review brain function monitors based on the processed electroencephalogram with regards to signal quality, artefacts and other limitations in clinical performance. RECENT FINDINGS Several studies have been showing that depth of anaesthesia monitors based on processed electroencephalogram has limitations that can lead to a wrong interpretation of the level of anaesthesia. Processed electroencephalogram indices can be altered by nonanaesthetic influences ranging from artefacts that affect signal quality and signal processing, adverse effects of some anaesthetic and nonanaesthetic drugs, neuromuscular blocking agents to conditions inherent to the patient such as cerebral tumours, brain ischemia and temperature. SUMMARY Clinicians should be aware of the several limitations of the commercial devices intending to monitor the depth of anaesthesia, which may not reflect the real underlying level of unconsciousness.
Collapse
|
16
|
Kortelainen J, Vayrynen E, Seppanen T. Isomap approach to EEG-based assessment of neurophysiological changes during anesthesia. IEEE Trans Neural Syst Rehabil Eng 2010; 19:113-20. [PMID: 21147597 DOI: 10.1109/tnsre.2010.2098420] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Increasing concentrations of anesthetics in the blood induce a continuum of neurophysiological changes, which reflect on the electroencephalogram (EEG). EEG-based depth of anesthesia assessment requires that the signal samples are correctly associated with the neurophysiological changes occurring at different anesthetic levels. A novel method is presented to estimate the phase of the continuum using the feature data extracted from EEG. The feature data calculated from EEG sequences corresponding to continuously deepening anesthesia are considered to form a one-dimensional nonlinear manifold in the multidimensional feature space. Utilizing a recently proposed algorithm, Isomap, the dimensionality of the feature data is reduced to achieve a one-dimensional embedding representing this manifold and thereby the continuum of neurophysiological changes during induction of anesthesia. The Isomap-based estimation is validated with data recorded from nine patients during induction of propofol anesthesia. The proposed method provides a novel approach to assess neurophysiological changes during anesthesia and offers potential for the development of more advanced systems for the depth of anesthesia monitoring.
Collapse
Affiliation(s)
- Jukka Kortelainen
- Department of Electrical and Information Engineering, University of Oulu, Finland.
| | | | | |
Collapse
|
17
|
Yang LQ, Song JC, Irwin MG, Song JG, Sun YM, Yu WF. A clinical prospective comparison of anesthetics sensitivity and hemodynamic effect among patients with or without obstructive jaundice. Acta Anaesthesiol Scand 2010; 54:871-7. [PMID: 20236100 DOI: 10.1111/j.1399-6576.2010.02222.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND To compare isoflurane anesthesia in patients with or without hyperbilirubinemia undergoing hepatobiliary surgery. METHODS Forty-two patients with obstructive jaundice and 40 control patients with normal liver function scheduled for hepatobiliary surgery under isoflurane anesthesia were studied. Anesthesia was induced with propofol (1.5-2 mg/kg) and remifentanil (2 microg/kg). After tracheal intubation, anesthesia was titrated using isoflurane in oxygen-enriched air, adjusted to maintain a bispectral index (BIS) value of 46-54. Ephedrine, atropine and remifentanil were used to maintain hemodynamic parameters within 30% of the baseline. The mean arterial blood pressure (MAP), heart rate (HR), drug doses and the time taken to recover from anesthesia were recorded. RESULTS Demographic data, duration and BIS values were similar in both groups. Anesthesia induction and maintenance were associated with more hemodynamic instability in the patients with jaundice and they received more ephedrine and atropine and less remifentanil and isoflurane (51.1+/-24.2 vs. 84.6+/-20.3 mg/min; P for all <0.05) than control patients. Despite less anesthetic use, the time to recovery and extubation was significantly longer than that in control. CONCLUSION Patients with obstructive jaundice have an increased sensitivity to isoflurane, more hypotension and bradycardia during anesthesia induction and maintenance and a prolonged recovery time compared with controls.
Collapse
Affiliation(s)
- L-Q Yang
- Department of Anesthesiology, the Second Military Medical University, Shanghai, China
| | | | | | | | | | | |
Collapse
|
18
|
Doufas AG, Komatsu R, Orhan-Sungur M, Sengupta P, Wadhwa A, Mascha E, Shafer SL, Sessler DI. Neuromuscular Block Differentially Affects Immobility and Cortical Activation at Near–Minimum Alveolar Concentration Anesthesia. Anesth Analg 2009; 109:1097-104. [DOI: 10.1213/ane.0b013e3181af631a] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
19
|
Jeanne M, Logier R, De Jonckheere J, Tavernier B. Heart rate variability during total intravenous anesthesia: Effects of nociception and analgesia. Auton Neurosci 2009; 147:91-6. [DOI: 10.1016/j.autneu.2009.01.005] [Citation(s) in RCA: 126] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2008] [Revised: 12/31/2008] [Accepted: 01/14/2009] [Indexed: 01/08/2023]
|
20
|
Saricaoglu F, Leblebicioglu G. Brachial plexus nerve stimulation and bispectral index levels under sevoflurane and remifentanil anaesthesia. Eur J Anaesthesiol 2009; 26:262-263. [PMID: 19237988 DOI: 10.1097/eja.0b013e32831bd92e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
|
21
|
Faraoni D, Salengros JC, Engelman E, Ickx B, Barvais L. Ketamine has no effect on bispectral index during stable propofol-remifentanil anaesthesia. Br J Anaesth 2009; 102:336-9. [PMID: 19189986 DOI: 10.1093/bja/aen403] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Ketamine 0.15-1 mg kg(-1) decreases postoperative morphine consumption, but 0.5 mg kg(-1) is associated with an increase in the bispectral index (BIS) values that can lead to an overdose of hypnotic agents. The purpose of our investigation was to study the effect of ketamine 0.2 mg kg(-1) administered over a 5 min period on the BIS during stable target-controlled infusion (TCI) propofol-remifentanil general anaesthesia. METHODS Thirty ASA I or II patients undergoing abdominal laparoscopic surgery were included in this double-blind, randomized study. Anaesthesia was induced and maintained with a TCI of propofol and remifentanil. After 5 min of steady-state anaesthesia (BIS at 40) without surgical stimulation, patients received either an infusion of ketamine 0.2 mg kg(-1) or normal saline. The test drug was infused over 5 min. Standard parameters and BIS values were recorded every minute until 15 min post-infusion. RESULTS The baseline mean (sd) value for the BIS was 37 (6.5) for the ketamine group and 39 (8.2) for the placebo group. The highest mean BIS value during the recording period was 41.5 (8.7) for the ketamine group and 40.1 (8.9) for the placebo group. BIS values were not statistically different between the groups (P=0.62); there was no significant change over time (P=0.65) with no group-time interaction (P=0.55). CONCLUSIONS Under stable propofol and remifentanil TCI anaesthesia, a slow bolus infusion of ketamine 0.2 mg kg(-1) administered over a 5 min period did not increase the BIS value over the next 15 min.
Collapse
Affiliation(s)
- D Faraoni
- CUB Erasmus Hospital, University Department of Anaesthesia-Reanimation, Route de Lennik, 808, Brussels, Belgium.
| | | | | | | | | |
Collapse
|
22
|
Sonkajärvi E, Alahuhta S, Suominen K, Hakalax N, Vakkuri A, Löppönen H, Ohtonen P, Jäntti V. Topographic electroencephalogram in children during mask induction of anaesthesia with sevoflurane. Acta Anaesthesiol Scand 2009; 53:77-84. [PMID: 19032567 DOI: 10.1111/j.1399-6576.2008.01725.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Epileptiform patterns, spikes, polyspikes and periodic epileptiform discharges (PED) have been reported in electroencephalograms (EEGs) during anaesthesia induction with sevoflurane in healthy adults and children. Published recordings have been performed with a limited number of channels, and therefore the topographic distributions of these patterns are not known. METHODS Twenty ASA I children aged 4-10 years undergoing routine operations were anaesthetized with 8% sevoflurane in 50%/50% oxygen and nitrous oxide using mask induction with controlled normoventilation. An EEG was recorded with a full 10-20 electrode system including orbitofrontal and ear electrodes, and a recording band of 0.016-70 Hz. Beat-to-beat heart rate (HR) was calculated off-line. RESULTS Nineteen out of 20 children developed multifocal spikes and polyspikes with a maximum over the frontal lobes. Four patients developed suppression, which was almost continuous and lasted several minutes, and thereafter a continuous EEG resumed, a few spikes were seen and then a nonepileptiform pattern. In three children a couple of PED waves were seen at the onset of a continuous EEG. HR increased maximally before the onset of spikes. No motor phenomena were seen. CONCLUSION These recordings confirm the epileptogenic property of sevoflurane in mask induction. The spikes and polyspikes had frontal multifocal maxima and may be missed in recordings from frontopolar electrodes used by depth-of-anaesthesia monitors. PED and burst suppression were synchronous over the whole cortex. Epileptiform activity was indiscernible from epileptiform waveforms without anaesthesia, such as the patterns seen in status epilepticus.
Collapse
Affiliation(s)
- E Sonkajärvi
- Departmetn of Anaesthesiology, Oulu University Hospital, Oulu, Finland.
| | | | | | | | | | | | | | | |
Collapse
|