1
|
Juneja D, Deepak D, Nasa P. What, why and how to monitor blood glucose in critically ill patients. World J Diabetes 2023; 14:528-538. [PMID: 37273246 PMCID: PMC10236998 DOI: 10.4239/wjd.v14.i5.528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 01/17/2023] [Accepted: 03/07/2023] [Indexed: 05/15/2023] Open
Abstract
Critically ill patients are prone to high glycemic variations irrespective of their diabetes status. This mandates frequent blood glucose (BG) monitoring and regulation of insulin therapy. Even though the most commonly employed capillary BG monitoring is convenient and rapid, it is inaccurate and prone to high bias, overestimating BG levels in critically ill patients. The targets for BG levels have also varied in the past few years ranging from tight glucose control to a more liberal approach. Each of these has its own fallacies, while tight control increases risk of hypoglycemia, liberal BG targets make the patients prone to hyperglycemia. Moreover, the recent evidence suggests that BG indices, such as glycemic variability and time in target range, may also affect patient outcomes. In this review, we highlight the nuances associated with BG monitoring, including the various indices required to be monitored, BG targets and recent advances in BG monitoring in critically ill patients.
Collapse
Affiliation(s)
- Deven Juneja
- Institute of Critical Care Medicine, Max Super Speciality Hospital, Saket, New Delhi 110017, India
| | - Desh Deepak
- Department of Critical Care, King's College Hospital, Dubai 340901, United Arab Emirates
| | - Prashant Nasa
- Department of Critical Care, NMC Speciality Hospital, Dubai 7832, United Arab Emirates
- Department of Critical Care, College of Medicine and Health Sciences, Al Ain 15551, United Arab Emirates
| |
Collapse
|
2
|
Lilleøre JG, Vittrup S, Tøstesen SK, Hanberg P, Stilling M, Bue M. Comparison of Intravenous Microdialysis and Standard Plasma Sampling for Monitoring of Vancomycin and Meropenem Plasma Concentrations-An Experimental Porcine Study. Antibiotics (Basel) 2023; 12:antibiotics12040791. [PMID: 37107154 PMCID: PMC10135263 DOI: 10.3390/antibiotics12040791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 04/13/2023] [Accepted: 04/19/2023] [Indexed: 04/29/2023] Open
Abstract
Microdialysis is a catheter-based method suitable for dynamic sampling of unbound antibiotic concentrations. Intravenous antibiotic concentration sampling by microdialysis has several advantages and may be a superior alternative to standard plasma sampling. We aimed to compare concentrations obtained by continuous intravenous microdialysis sampling and by standard plasma sampling of both vancomycin and meropenem in a porcine model. Eight female pigs received 1 g of both vancomycin and meropenem, simultaneously over 100 and 10 min, respectively. Prior to drug infusion, an intravenous microdialysis catheter was placed in the subclavian vein. Microdialysates were collected for 8 h. From a central venous catheter, plasma samples were collected in the middle of every dialysate sampling interval. A higher area under the concentration/time curve and peak drug concentration were found in standard plasma samples compared to intravenous microdialysis samples, for both vancomycin and meropenem. Both vancomycin and meropenem concentrations obtained with intravenous microdialysis were generally lower than from standard plasma sampling. The differences in key pharmacokinetic parameters between the two sampling techniques underline the importance of further investigations to find the most suitable and reliable method for continuous intravenous antibiotic concentration sampling.
Collapse
Affiliation(s)
- Johanne Gade Lilleøre
- Department of Clinical Medicine, Aarhus University, 8200 Aarhus, Denmark
- Aarhus Denmark Microdialysis Research Group (ADMIRE), Aarhus University Hospital, 8200 Aarhus, Denmark
| | - Sofus Vittrup
- Department of Clinical Medicine, Aarhus University, 8200 Aarhus, Denmark
- Aarhus Denmark Microdialysis Research Group (ADMIRE), Aarhus University Hospital, 8200 Aarhus, Denmark
| | - Sara Kousgaard Tøstesen
- Department of Clinical Medicine, Aarhus University, 8200 Aarhus, Denmark
- Aarhus Denmark Microdialysis Research Group (ADMIRE), Aarhus University Hospital, 8200 Aarhus, Denmark
| | - Pelle Hanberg
- Department of Clinical Medicine, Aarhus University, 8200 Aarhus, Denmark
- Aarhus Denmark Microdialysis Research Group (ADMIRE), Aarhus University Hospital, 8200 Aarhus, Denmark
| | - Maiken Stilling
- Department of Clinical Medicine, Aarhus University, 8200 Aarhus, Denmark
- Aarhus Denmark Microdialysis Research Group (ADMIRE), Aarhus University Hospital, 8200 Aarhus, Denmark
- Department of Orthopedic Surgery, Aarhus University Hospital, 8200 Aarhus, Denmark
| | - Mats Bue
- Department of Clinical Medicine, Aarhus University, 8200 Aarhus, Denmark
- Aarhus Denmark Microdialysis Research Group (ADMIRE), Aarhus University Hospital, 8200 Aarhus, Denmark
- Department of Orthopedic Surgery, Aarhus University Hospital, 8200 Aarhus, Denmark
| |
Collapse
|
3
|
Microdialysis techniques and microdialysis-based patient-near diagnostics. Anal Bioanal Chem 2022; 414:3165-3175. [PMID: 35028692 DOI: 10.1007/s00216-021-03830-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 11/17/2021] [Accepted: 12/03/2021] [Indexed: 01/04/2023]
Abstract
This article will debate the usefulness of POCT measurements and the contribution microdialysis can make to generating valuable information. A particular theme will be the rarely considered difference between ex vivo sampling, which typically generates only a static measure of concentration, and in vivo measurements that are subject to dynamic changes due to mass transfer. Those dynamic changes provide information about the patients' physiological state.
Collapse
|
4
|
Dynamic properties of glucose complexity during the course of critical illness: a pilot study. J Clin Monit Comput 2020; 34:361-370. [PMID: 30888595 DOI: 10.1007/s10877-019-00299-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Accepted: 03/13/2019] [Indexed: 10/27/2022]
Abstract
Methods to control the blood glucose (BG) levels of patients in intensive care units (ICU) improve the outcomes. The development of continuous BG levels monitoring devices has also permitted to optimize these processes. Recently it was shown that a complexity loss of the BG signal is linked to poor clinical outcomes. Thus, it becomes essential to decipher this relation to design efficient BG level control methods. In previous studies the BG signal complexity was calculated as a single index for the whole ICU stay. Although, these approaches did not grasp the potential variability of the BG signal complexity. Therefore, we setup this pilot study using a continuous monitoring of central venous BG levels in ten critically ill patients (EIRUS platform, Maquet Critical CARE AB, Solna, Sweden). Data were processed and the complexity was assessed by the detrended fluctuation analysis and multiscale entropy (MSE) methods. Finally, recordings were split into 24 h overlapping intervals and a MSE analysis was applied to each of them. The MSE analysis on time intervals revealed an entropy variation and allowed periodic BG signal complexity assessments. To highlight differences of MSE between each time interval we calculated the MSE complexity index defined as the area under the curve. This new approach could pave the way to future studies exploring new strategies aimed at restoring blood glucose complexity during the ICU stay.
Collapse
|
5
|
Krinsley JS, Chase JG, Gunst J, Martensson J, Schultz MJ, Taccone FS, Wernerman J, Bohe J, De Block C, Desaive T, Kalfon P, Preiser JC. Continuous glucose monitoring in the ICU: clinical considerations and consensus. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2017; 21:197. [PMID: 28756769 PMCID: PMC5535285 DOI: 10.1186/s13054-017-1784-0] [Citation(s) in RCA: 79] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Glucose management in intensive care unit (ICU) patients has been a matter of debate for almost two decades. Compared to intermittent monitoring systems, continuous glucose monitoring (CGM) can offer benefit in the prevention of severe hyperglycemia and hypoglycemia by enabling insulin infusions to be adjusted more rapidly and potentially more accurately because trends in glucose concentrations can be more readily identified. Increasingly, it is apparent that a single glucose target/range may not be optimal for all patients at all times and, as with many other aspects of critical care patient management, a personalized approach to glucose control may be more appropriate. Here we consider some of the evidence supporting different glucose targets in various groups of patients, focusing on those with and without diabetes and neurological ICU patients. We also discuss some of the reasons why, despite evidence of benefit, CGM devices are still not widely employed in the ICU and propose areas of research needed to help move CGM from the research arena to routine clinical use.
Collapse
Affiliation(s)
- James S Krinsley
- Division of Critical Care, Department of Medicine, Stamford Hospital, Columbia University College of Physicians and Surgeons, Stamford, CT, 06902, USA
| | - J Geoffrey Chase
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, 8140, New Zealand
| | - Jan Gunst
- Clinical Division and Laboratory of Intensive Care Medicine, Department of Cellular and Molecular Medicine, KU Leuven, 3000, Leuven, Belgium
| | - Johan Martensson
- Department of Intensive Care, Austin Hospital, Heidelberg, 3084, VIC, Australia.,Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Department of Physiology and Pharmacology, Karolinska Institutet, 171 77, Stockholm, Sweden
| | - Marcus J Schultz
- Academic Medical Center, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.,Department of Intensive Care, Laboratory of Experimental Intensive Care and Anesthesia (L E I C A), Faculty of Tropical Medicine, Mahidol University, Mahidol-Oxford Research Unit (MORU), Bangkok, Thailand
| | - Fabio S Taccone
- Department of Intensive Care, Erasme Hospital, Université libre de Bruxelles, 1070, Brussels, Belgium
| | - Jan Wernerman
- Karolinska University Hospital Huddinge & Karolinska Institutet, K32 14186, Stockholm, Sweden
| | - Julien Bohe
- Medical Intensive Care Unit, University Hospital of Lyon, Lyon, France
| | - Christophe De Block
- Department of Endocrinology, Diabetology and Metabolism, Antwerp University Hospital, B-2650, Edegem, Belgium
| | - Thomas Desaive
- GIGA-In Silico Medicine, Université de Liège, B4000, Liège, Belgium
| | - Pierre Kalfon
- Service de Réanimation polyvalente, Hôpital Louis Pasteur, CH de Chartres, 28000, Chartres, France
| | - Jean-Charles Preiser
- Department of Intensive Care, Erasme Hospital, Université libre de Bruxelles, 1070, Brussels, Belgium.
| |
Collapse
|
6
|
Azeredo FJ, Dalla Costa T, Derendorf H. Role of microdialysis in pharmacokinetics and pharmacodynamics: current status and future directions. Clin Pharmacokinet 2014; 53:205-212. [PMID: 24452811 DOI: 10.1007/s40262-014-0131-8] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Diagnostic and therapeutic decisions in medical practice are still generally based on blood concentrations of drugs and/or biomolecules despite the knowledge that biochemical events and pharmacological effects usually take place in tissue rather than in the bloodstream. Microdialysis is a semi-invasive technique that is able to measure concentrations of the free, active drug or endogenous compounds in almost all human tissues and organs. It is currently being used to monitor brain metabolic processes and quantify tissue biomarkers, and determine transdermal drug distribution and tissue pharmacokinetics, confirming its importance as a widely used sampling technique in clinical drug monitoring and drug development as well as therapy and disease follow-up, contributing to rationalizing drug dosing regimens and influencing the clinical decision-making process.
Collapse
Affiliation(s)
| | - Teresa Dalla Costa
- Programa de Pós-Graduação em Ciências Farmacêuticas, UFRGS, Porto Alegre, Brazil
| | - Hartmut Derendorf
- Department of Pharmaceutics, College of Pharmacy, University of Florida, 1600 SW Archer Road, Gainesville, FL, 32610, USA.
| |
Collapse
|
7
|
Thelin EP, Nelson DW, Ghatan PH, Bellander BM. Microdialysis Monitoring of CSF Parameters in Severe Traumatic Brain Injury Patients: A Novel Approach. Front Neurol 2014; 5:159. [PMID: 25228896 PMCID: PMC4151035 DOI: 10.3389/fneur.2014.00159] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2014] [Accepted: 08/06/2014] [Indexed: 01/22/2023] Open
Abstract
Background: Neuro-intensive care following traumatic brain injury (TBI) is focused on preventing secondary insults that may lead to irreversible brain damage. Microdialysis (MD) is used to detect deranged cerebral metabolism. The clinical usefulness of the MD is dependent on the regional localization of the MD catheter. The aim of this study was to analyze a new method of continuous cerebrospinal fluid (CSF) monitoring using the MD technique. The method was validated using conventional laboratory analysis of CSF samples. MD-CSF and regional MD-Brain samples were correlated to patient outcome. Materials and Methods: A total of 14 patients suffering from severe TBI were analyzed. They were monitored using (1) a MD catheter (CMA64-iView, n = 7448 MD samples) located in a CSF-pump connected to the ventricular drain and (2) an intraparenchymal MD catheter (CMA70, n = 8358 MD samples). CSF-lactate and CSF-glucose levels were monitored and were compared to MD-CSF samples. MD-CSF and MD-Brain parameters were correlated to favorable (Glasgow Outcome Score extended, GOSe 6–8) and unfavorable (GOSe 1–5) outcome. Results: Levels of glucose and lactate acquired with the CSF-MD technique could be correlated to conventional levels. The median MD recovery using the CMA64 catheter in CSF was 0.98 and 0.97 for glucose and lactate, respectively. Median MD-CSF (CMA 64) lactate (p = 0.0057) and pyruvate (p = 0.0011) levels were significantly lower in the favorable outcome group compared to the unfavorable group. No significant difference in outcome was found using the lactate:pyruvate ratio (LPR), or any of the regional MD-Brain monitoring in our analyzed cohort. Conclusion: This new technique of global MD-CSF monitoring correlates with conventional CSF levels of glucose and lactate, and the MD recovery is higher than previously described. Increase in lactate and pyruvate, without any effect on the LPR, correlates to unfavorable outcome, perhaps related to the presence of erythrocytes in the CSF.
Collapse
Affiliation(s)
- Eric P Thelin
- Section for Neurosurgery, Department of Clinical Neuroscience, Karolinska Institutet, Karolinska University Hospital Solna , Stockholm , Sweden
| | - David W Nelson
- Section of Anesthesiology and Intensive Care, Department of Physiology and Pharmacology, Karolinska Institutet , Stockholm , Sweden
| | - Per Hamid Ghatan
- Department of Clinical Neuroscience, Karolinska Institutet , Stockholm , Sweden
| | - Bo-Michael Bellander
- Section for Neurosurgery, Department of Clinical Neuroscience, Karolinska Institutet, Karolinska University Hospital Solna , Stockholm , Sweden
| |
Collapse
|
8
|
Wernerman J, Desaive T, Finfer S, Foubert L, Furnary A, Holzinger U, Hovorka R, Joseph J, Kosiborod M, Krinsley J, Mesotten D, Nasraway S, Rooyackers O, Schultz MJ, Van Herpe T, Vigersky RA, Preiser JC. Continuous glucose control in the ICU: report of a 2013 round table meeting. Crit Care 2014; 18:226. [PMID: 25041718 PMCID: PMC4078395 DOI: 10.1186/cc13921] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Achieving adequate glucose control in critically ill patients is a complex but important part of optimal patient management. Until relatively recently, intermittent measurements of blood glucose have been the only means of monitoring blood glucose levels. With growing interest in the possible beneficial effects of continuous over intermittent monitoring and the development of several continuous glucose monitoring (CGM) systems, a round table conference was convened to discuss and, where possible, reach consensus on the various aspects related to glucose monitoring and management using these systems. In this report, we discuss the advantages and limitations of the different types of devices available, the potential advantages of continuous over intermittent testing, the relative importance of trend and point accuracy, the standards necessary for reporting results in clinical trials and for recognition by official bodies, and the changes that may be needed in current glucose management protocols as a result of a move towards increased use of CGM. We close with a list of the research priorities in this field, which will be necessary if CGM is to become a routine part of daily practice in the management of critically ill patients.
Collapse
Affiliation(s)
- Jan Wernerman
- Department of Anesthesiology and Intensive Care Medicine, K32, Karolinska University Hospital, Stockholm, Huddinge 14186, Sweden
| | - Thomas Desaive
- GIGA - Cardiovascular Sciences, University of Liege, Institute of Physics, B5, Allee du 6 aout, 17, Liege 4000, Belgium
| | - Simon Finfer
- The George Institute for Global Health and Royal North Shore Hospital, University of Sydney, St Leonards, Sydney, NSW 2065, Australia
| | - Luc Foubert
- Department of Anesthesia and Intensive Care Medicine, OLV Clinic, Aalst 9300, Belgium
| | - Anthony Furnary
- Starr-Wood Cardiac Group, 9155 SW Barnes Road, Portland, OR 97225-6629, USA
| | - Ulrike Holzinger
- Department of Medicine III - Division of Gastroenterology and Hepatology, Medical University of Vienna, Waehringer Guertel 18-20, Vienna 1090, Austria
| | - Roman Hovorka
- University of Cambridge Metabolic Research Laboratories, Level 4, Wellcome trust MRC Institute of Metabolic Science, Box 289, Addenbrooke’s Hospital, Hills Road, Cambridge CB2 0QQ, UK
| | - Jeffrey Joseph
- Jefferson Artificial Pancreas Center and Anesthesiology Program for Translational Research, Department of Anesthesiology, Jefferson Medical College of Thomas Jefferson University, 1020 Walnut Street, Philadelphia, PA 19107, USA
| | - Mikhail Kosiborod
- Saint-Luke’s Mid America Heart Institute, University of Missouri - Kansas City, 4401 Wornall Road, Kansas City, MO 64111, USA
| | - James Krinsley
- Division of Critical Care, Stamford Hospital and Columbia University College of Physicians and Surgeons, 30 Shelburne Road, Stamford, CT 06904, USA
| | - Dieter Mesotten
- Department of Intensive Care Medicine, University Hospitals Leuven, Herestraat 49, Leuven B-3000, Belgium
| | - Stanley Nasraway
- Surgical Intensive Care Units, Tufts Medical Center, 800 Washington Street, NEMC 4360, Boston, MA 02111, USA
| | - Olav Rooyackers
- Anesthesiology and Intensive Care Clinic, Karolinska Institute and University Hospital, Huddinge 14186, Sweden
| | - Marcus J Schultz
- Department of Intensive Care Medicine, Academic Medical Center at the University of Amsterdam, Meibergdreef 9, Amsterdam 1105 AZ, The Netherlands
| | - Tom Van Herpe
- Department of Intensive Care Medicine, University Hospitals Leuven, Herestraat 49, Leuven B-3000, Belgium
- Department of Electrical Engineering (STADIUS) - iMinds Future Health Department, Katholieke Universiteit Leuven, Leuven, Heverlee B-3001, Belgium
| | - Robert A Vigersky
- Diabetes Institute, Walter Reed National Military Medical Center, Bethesda, MD 20895, USA
| | - Jean-Charles Preiser
- Department of Intensive Care, Erasme Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels 1070, Belgium
| |
Collapse
|
9
|
Role of microdialysis in pharmacokinetics and pharmacodynamics: current status and future directions. Clin Pharmacokinet 2014. [PMID: 24452811 DOI: 10.1007/s40262–014-0131–8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/29/2022]
Abstract
Diagnostic and therapeutic decisions in medical practice are still generally based on blood concentrations of drugs and/or biomolecules despite the knowledge that biochemical events and pharmacological effects usually take place in tissue rather than in the bloodstream. Microdialysis is a semi-invasive technique that is able to measure concentrations of the free, active drug or endogenous compounds in almost all human tissues and organs. It is currently being used to monitor brain metabolic processes and quantify tissue biomarkers, and determine transdermal drug distribution and tissue pharmacokinetics, confirming its importance as a widely used sampling technique in clinical drug monitoring and drug development as well as therapy and disease follow-up, contributing to rationalizing drug dosing regimens and influencing the clinical decision-making process.
Collapse
|
10
|
Blixt C, Rooyackers O, Isaksson B, Wernerman J. Continuous on-line glucose measurement by microdialysis in a central vein. A pilot study. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2013; 17:R87. [PMID: 23663747 PMCID: PMC3707045 DOI: 10.1186/cc12713] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2012] [Accepted: 05/11/2013] [Indexed: 01/04/2023]
Abstract
Introduction Tight glucose control in the ICU has been proven difficult with an increased risk for hypoglycaemic episodes. Also the variability of glucose may have an impact on morbidity. An accurate and feasible on-line/continuous measurement is therefore desired. In this study a central vein catheter with a microdialysis membrane in combination with an on-line analyzer for continuous monitoring of circulating glucose and lactate by the central route was tested. Methods A total of 10 patients scheduled for major upper abdominal surgery were included in this observational prospective study at a university hospital. The patients received an extra central venous catheter with a microdialysis membrane placed in the right jugular vein. Continuous microdialysis measurement proceeded for 20 hours and on-line values were recorded every minute. Reference arterial plasma glucose and blood lactate samples were collected every hour. Results Mean microdialysis-glucose during measurements was 9.8 ± 2.4mmol/l.No statistical difference in the readings was seen using a single calibration compared to eighth hour calibration (P =0.09; t-test). There was a close agreement between the continuous reading and the reference plasma glucose values with an absolute difference of 0.6+0.8mmol, or 6.8+9.3% and measurements showed high correlation to plasma readings (r = 0.92). Thelimit of agreement was 23.0%(1.94 mmol/l) compared to arterial plasma values with a line of equality close to zero.However, in a Clarke-Error Grid 93.3% of the values are in the A-area,and the remaining part in the B-area.Mean microdialysis-lactate was 1.3 ± 1.1mmol/l. The measurements showed high correlation to the blood readings (r = 0.93). Conclusion Continuous on-line microdialysis glucose measurement in a central vein is a potential useful technique for continuous glucose monitoring in critically ill patients, but more improvements and testingare needed.
Collapse
|
11
|
Rooyackers O, Blixt C, Mattsson P, Wernerman J. Continuous glucose monitoring by intravenous microdialysis: influence of membrane length and dialysis flow rate. Acta Anaesthesiol Scand 2013; 57:214-9. [PMID: 23075419 DOI: 10.1111/j.1399-6576.2012.02787.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/26/2012] [Indexed: 12/17/2022]
Abstract
BACKGROUND The benefit of tight glucose control in the intensive care unit is controversial. Part of the debate is around the frequency of glucose measurements, and therefore, a continuous glucose monitoring system is needed. Previously, we have shown that intravenous microdialysis has the potential for this purpose but that the accuracy must be improved. The aim of this study was to investigate the effects of the microdialysis membrane length and the perfusion rate on improving the accuracy. METHODS Two volunteer studies were performed, one comparing intravenous microdialysis catheters with different lengths (10 and 20 mm) and one comparing different perfusion rates (0.5, 1 and 2 μl/min) with plasma glucose reference levels. Median values of seven samples taken over 70-min periods were compared using Bland-Altman plots. RESULTS When microdialysis membranes of 10 and 20 mm perfused at a rate of 1 μl/min were used, the differences with measured plasma glucose levels were 30% ± 21% and 14% ± 13%. In comparison, plasma glucose measured in two different veins gave a difference of 3% ± 3%. In the second study, the differences between measured plasma glucose and that estimated with a microdialysis membrane of 30 mm perfused at 0.5, 1 and 2 μl/min were 8% ± 7%, 25% ± 19% and 39% ± 28%. Bland-Altman analyses gave the best line of equality (-0.11 mM) and the lowest limits of agreement (1.13 and -1.35 mM) when using the 30-mm membrane perfused with 0.5 μl/min. CONCLUSION The agreement of the intravenous microdialysis with plasma glucose levels improved significantly when increasing the microdialysis membrane length, and thereby the membrane area, and decreasing the perfusion rate.
Collapse
Affiliation(s)
- O Rooyackers
- Department of Anesthesiology and Intensive Care Medicine, Karolinska University Hospital, Huddinge, Sweden
| | | | | | | |
Collapse
|
12
|
Mader JK, Feichtner F, Bock G, Köhler G, Schaller R, Plank J, Pieber TR, Ellmerer M. Microdialysis--a versatile technology to perform metabolic monitoring in diabetes and critically ill patients. Diabetes Res Clin Pract 2012; 97:112-8. [PMID: 22402305 DOI: 10.1016/j.diabres.2012.02.010] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2011] [Revised: 01/20/2012] [Accepted: 02/14/2012] [Indexed: 11/24/2022]
Abstract
Continuous subcutaneous glucose monitoring has been tested in type 1 diabetes (T1D). Since in critically ill patients vascular access is granted vascular microdialysis may be preferential. To test this hypothesis comparative accuracy data for microdialysis applied for peripheral venous and subcutaneous glucose monitoring was obtained in experiments in T1D patients. Twelve T1D patients were investigated for up to 30 h. Extracorporeal vascular (MDv) and subcutaneous microdialysis (MDs) was performed. Microdialysis samples were collected in 15-60 min intervals, analyzed for glucose and calibrated to reference. MDv and MDs glucose levels were compared against reference. Median absolute relative difference was 14.0 (5.0; 28.0)% (MDv) and 9.2 (4.4; 18.4)% (MDs). Clarke Error Grid analysis showed that 100% (MDv) and 98.8% (MDv) were within zones A and B. Extracorporeal vascular and standard subcutaneous microdialysis indicated similar performance in T1D. We suggest microdialysis as a versatile technology for metabolite monitoring in subcutaneous tissue and whole blood.
Collapse
Affiliation(s)
- Julia K Mader
- Department of Internal Medicine, Medical University of Graz, Graz, Austria.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
|
14
|
Blevins TC, Bode BW, Garg SK, Grunberger G, Hirsch IB, Jovanovič L, Nardacci E, Orzeck EA, Roberts VL, Tamborlane WV, Rothermel C. Statement by the American Association of Clinical Endocrinologists Consensus Panel on continuous glucose monitoring. Endocr Pract 2011; 16:730-45. [PMID: 21356637 DOI: 10.4158/ep.16.5.730] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|