1
|
Müllenbroich MC, Kelly A, Acker C, Bub G, Bruegmann T, Di Bona A, Entcheva E, Ferrantini C, Kohl P, Lehnart SE, Mongillo M, Parmeggiani C, Richter C, Sasse P, Zaglia T, Sacconi L, Smith GL. Novel Optics-Based Approaches for Cardiac Electrophysiology: A Review. Front Physiol 2021; 12:769586. [PMID: 34867476 PMCID: PMC8637189 DOI: 10.3389/fphys.2021.769586] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 10/18/2021] [Indexed: 12/31/2022] Open
Abstract
Optical techniques for recording and manipulating cellular electrophysiology have advanced rapidly in just a few decades. These developments allow for the analysis of cardiac cellular dynamics at multiple scales while largely overcoming the drawbacks associated with the use of electrodes. The recent advent of optogenetics opens up new possibilities for regional and tissue-level electrophysiological control and hold promise for future novel clinical applications. This article, which emerged from the international NOTICE workshop in 2018, reviews the state-of-the-art optical techniques used for cardiac electrophysiological research and the underlying biophysics. The design and performance of optical reporters and optogenetic actuators are reviewed along with limitations of current probes. The physics of light interaction with cardiac tissue is detailed and associated challenges with the use of optical sensors and actuators are presented. Case studies include the use of fluorescence recovery after photobleaching and super-resolution microscopy to explore the micro-structure of cardiac cells and a review of two photon and light sheet technologies applied to cardiac tissue. The emergence of cardiac optogenetics is reviewed and the current work exploring the potential clinical use of optogenetics is also described. Approaches which combine optogenetic manipulation and optical voltage measurement are discussed, in terms of platforms that allow real-time manipulation of whole heart electrophysiology in open and closed-loop systems to study optimal ways to terminate spiral arrhythmias. The design and operation of optics-based approaches that allow high-throughput cardiac electrophysiological assays is presented. Finally, emerging techniques of photo-acoustic imaging and stress sensors are described along with strategies for future development and establishment of these techniques in mainstream electrophysiological research.
Collapse
Affiliation(s)
| | - Allen Kelly
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, United Kingdom
| | - Corey Acker
- Center for Cell Analysis and Modeling, UConn Health, Farmington, CT, United States
| | - Gil Bub
- Department of Physiology, McGill University, Montréal, QC, Canada
| | - Tobias Bruegmann
- Institute for Cardiovascular Physiology, University Medical Center Goettingen, Goettingen, Germany
| | - Anna Di Bona
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Emilia Entcheva
- Department of Biomedical Engineering, The George Washington University, Washington, DC, United States
| | | | - Peter Kohl
- Institute for Experimental Cardiovascular Medicine, University Heart Center and Medical Faculty, University of Freiburg, Freiburg, Germany
| | - Stephan E. Lehnart
- Heart Research Center Göttingen, University Medical Center Göttingen, Göttingen, Germany
- Department of Cardiology and Pneumology, Georg-August University Göttingen, Göttingen, Germany
- Cluster of Excellence “Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC), University of Göttingen, Göttingen, Germany
| | - Marco Mongillo
- Department of Biomedical Sciences, University of Padova, Padova, Italy
- Veneto Institute of Molecular Medicine, Padova, Italy
| | | | - Claudia Richter
- German Primate Center - Leibniz Institute for Primate Research, Göttingen, Germany
| | - Philipp Sasse
- Institute of Physiology I, Medical Faculty, University of Bonn, Bonn, Germany
| | - Tania Zaglia
- Department of Biomedical Sciences, University of Padova, Padova, Italy
- Veneto Institute of Molecular Medicine, Padova, Italy
| | - Leonardo Sacconi
- European Laboratory for Nonlinear Spectroscopy, Sesto Fiorentino, Italy
- Institute for Experimental Cardiovascular Medicine, University Heart Center and Medical Faculty, University of Freiburg, Freiburg, Germany
- National Institute of Optics, National Research Council, Florence, Italy
| | - Godfrey L. Smith
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, United Kingdom
| |
Collapse
|
2
|
George SA, Efimov IR. Optocardiography: A Review of its Past, Present and Future. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2019; 9:74-80. [PMID: 31803858 PMCID: PMC6892455 DOI: 10.1016/j.cobme.2019.03.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Cardiac electrophysiology has progressed in great strides since the electrical activity of the heart was first discovered in 1842 and documented using electrocardiography. Optical imaging of cardiac electrophysiology, or optocardiography, has seen many advances in recent years including panoramic imaging of the heart, alternating transillumination to image transmural electrical activity, optogenetic models and customizable 3D printed optical mapping systems. Most of these techniques were adopted from other fields of study and refined for cardiac electrophysiology purposes. The future of this field could see similar adaptations of photoacoustic tomography, structured light technology and optical coherence tomography contributing to optocardiography.
Collapse
Affiliation(s)
- Sharon A George
- Department of Biomedical Engineering, The George Washington University, Washington, DC
| | - Igor R Efimov
- Department of Biomedical Engineering, The George Washington University, Washington, DC
| |
Collapse
|
3
|
Walton RD, Bernus O. Towards Depth-Resolved Optical Imaging of Cardiac Electrical Activity. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2015; 859:405-23. [DOI: 10.1007/978-3-319-17641-3_16] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
4
|
Jing L, Brownson K, Patwardhan A. Role of slow delayed rectifying potassium current in dynamics of repolarization and electrical memory in swine ventricles. J Physiol Sci 2014; 64:185-93. [PMID: 24682806 PMCID: PMC10717138 DOI: 10.1007/s12576-014-0310-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Accepted: 03/03/2014] [Indexed: 01/26/2023]
Abstract
Dynamics of repolarization, quantified as restitution and electrical memory, impact conduction stability. Relatively less is known about role of slow delayed rectifying potassium current, I(Ks), in dynamics of repolarization and memory compared to the rapidly activating current I(Kr). Trans-membrane potentials were recorded from right ventricular tissues from pigs during reduction (chromanol 293B) and increases in I(Ks) (mefenamic acid). A novel pacing protocol was used to explicitly control diastolic intervals to quantify memory. Restitution hysteresis, a consequence of memory, increased after chromanol 293B (loop thickness and area increased 27 and 38 %) and decreased after mefenamic acid (52 and 53 %). Standard and dynamic restitutions showed an increase in average slope after chromanol 293B and a decrease after mefenamic acid. Increase in slope and memory are hypothesized to have opposite effects on electrical stability; therefore, these results suggest that reduction and enhancement of I(Ks) likely also have offsetting components that affect stability.
Collapse
Affiliation(s)
- Linyuan Jing
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY USA
| | - Kathleen Brownson
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY USA
| | - Abhijit Patwardhan
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY USA
| |
Collapse
|
5
|
Abstract
Optogenetics is an emerging technology for optical interrogation and control of biological function with high specificity and high spatiotemporal resolution. Mammalian cells and tissues can be sensitized to respond to light by a relatively simple and well-tolerated genetic modification using microbial opsins (light-gated ion channels and pumps). These can achieve fast and specific excitatory or inhibitory response, offering distinct advantages over traditional pharmacological or electrical means of perturbation. Since the first demonstrations of utility in mammalian cells (neurons) in 2005, optogenetics has spurred immense research activity and has inspired numerous applications for dissection of neural circuitry and understanding of brain function in health and disease, applications ranging from in vitro to work in behaving animals. Only recently (since 2010), the field has extended to cardiac applications with less than a dozen publications to date. In consideration of the early phase of work on cardiac optogenetics and the impact of the technique in understanding another excitable tissue, the brain, this review is largely a perspective of possibilities in the heart. It covers the basic principles of operation of light-sensitive ion channels and pumps, the available tools and ongoing efforts in optimizing them, overview of neuroscience use, as well as cardiac-specific questions of implementation and ideas for best use of this emerging technology in the heart.
Collapse
Affiliation(s)
- Emilia Entcheva
- Department of Biomedical Engineering, Department of Physiology and Biophysics, and Institute for Molecular Cardiology, Stony Brook University, Stony Brook, New York, USA
| |
Collapse
|
6
|
Pop M, Sermesant M, Liu G, Relan J, Mansi T, Soong A, Peyrat JM, Truong MV, Fefer P, McVeigh ER, Delingette H, Dick AJ, Ayache N, Wright GA. Construction of 3D MR image-based computer models of pathologic hearts, augmented with histology and optical fluorescence imaging to characterize action potential propagation. Med Image Anal 2011; 16:505-23. [PMID: 22209561 DOI: 10.1016/j.media.2011.11.007] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2010] [Revised: 11/06/2011] [Accepted: 11/15/2011] [Indexed: 11/29/2022]
Abstract
Cardiac computer models can help us understand and predict the propagation of excitation waves (i.e., action potential, AP) in healthy and pathologic hearts. Our broad aim is to develop accurate 3D MR image-based computer models of electrophysiology in large hearts (translatable to clinical applications) and to validate them experimentally. The specific goals of this paper were to match models with maps of the propagation of optical AP on the epicardial surface using large porcine hearts with scars, estimating several parameters relevant to macroscopic reaction-diffusion electrophysiological models. We used voltage-sensitive dyes to image AP in large porcine hearts with scars (three specimens had chronic myocardial infarct, and three had radiofrequency RF acute scars). We first analyzed the main AP waves' characteristics: duration (APD) and propagation under controlled pacing locations and frequencies as recorded from 2D optical images. We further built 3D MR image-based computer models that have information derived from the optical measures, as well as morphologic MRI data (i.e., myocardial anatomy, fiber directions and scar definition). The scar morphology from MR images was validated against corresponding whole-mount histology. We also compared the measured 3D isochronal maps of depolarization to simulated isochrones (the latter replicating precisely the experimental conditions), performing model customization and 3D volumetric adjustments of the local conductivity. Our results demonstrated that mean APD in the border zone (BZ) of the infarct scars was reduced by ~13% (compared to ~318 ms measured in normal zone, NZ), but APD did not change significantly in the thin BZ of the ablation scars. A generic value for velocity ratio (1:2.7) in healthy myocardial tissue was derived from measured values of transverse and longitudinal conduction velocities relative to fibers direction (22 cm/s and 60 cm/s, respectively). The model customization and 3D volumetric adjustment reduced the differences between measurements and simulations; for example, from one pacing location, the adjustment reduced the absolute error in local depolarization times by a factor of 5 (i.e., from 58 ms to 11 ms) in the infarcted heart, and by a factor of 6 (i.e., from 60 ms to 9 ms) in the heart with the RF scar. Moreover, the sensitivity of adjusted conductivity maps to different pacing locations was tested, and the errors in activation times were found to be of approximately 10-12 ms independent of pacing location used to adjust model parameters, suggesting that any location can be used for model predictions.
Collapse
Affiliation(s)
- Mihaela Pop
- Department of Medical Biophysics, University of Toronto, Sunnybrook Research Institute, Toronto, Ontario, Canada.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Kong W, Pollard AE, Fast VG. A new optrode design for intramural optical recordings. IEEE Trans Biomed Eng 2011; 58:3130-4. [PMID: 21914565 DOI: 10.1109/tbme.2011.2167623] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Intramural measurements of V(m) and Ca(i)(2+) are important in the studies of cardiac arrhythmias and defibrillation. We developed a new design of an "optrode" (bundle of optical fibers) for use in intramural cardiac mapping. The optrodes are made from seven optical fibers with the fiber ends polished at 45° angle and coated with mirror surfaces. The optrodes are enclosed in smooth epoxy resin cast, which protects mirror surfaces from damage and ensures constant optrode diameter along its length. The optrodes are strong enough to be easily inserted into heart muscle, can be reused multiple times, and they may reduce artifacts in the measurements of the effects of defibrillation shocks on V(m).
Collapse
Affiliation(s)
- Wei Kong
- Department of Biomedical Engineering, University of Alabama, Birmingham, AL 35294, USA
| | | | | |
Collapse
|
8
|
Mitrea BG, Caldwell BJ, Pertsov AM. Imaging electrical excitation inside the myocardial wall. BIOMEDICAL OPTICS EXPRESS 2011; 2:620-633. [PMID: 21412467 PMCID: PMC3047367 DOI: 10.1364/boe.2.000620] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2011] [Revised: 02/11/2011] [Accepted: 02/13/2011] [Indexed: 05/26/2023]
Abstract
Cardiac arrhythmias are often triggered by ectopic membrane depolarization originating deep inside the myocardial wall. Here we propose a new method utilizing a novel near-infrared voltage-sensitive fluorescent dye DI-4-ANBDQBS to determine the three-dimensional (3D) coordinates of the sources of such depolarization. We tested the method in live preparations of pig left and right ventricular myocardium (thickness 8-18 mm) and phantoms imitating the optical properties of myocardial tissue. The method utilizes an alternating transillumination approach that involves comparing pairs of simultaneously recorded broad-field epifluorescence and transillumination images produced at two alternating directions of illumination. Recordings were taken simultaneously by two CCD cameras facing the endocardial and epicardial surfaces of the heart at a frame rate up to 3 KHz. In live preparations, we were able to localize the origin of the depolarization wave with a precision of ±1.3mm in the transmural direction and 3 mm in the image plane. The accuracy of detection was independent of the depth of the source inside ventricular wall.
Collapse
|
9
|
Roth BJ. Optical imaging of the heart: Seeing below the surface. Heart Rhythm 2010; 7:1850-1. [PMID: 20833267 DOI: 10.1016/j.hrthm.2010.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2010] [Indexed: 10/19/2022]
|
10
|
Walton RD, Mitrea BG, Pertsov AM, Bernus O. A novel near-infrared voltage-sensitive dye reveals the action potential wavefront orientation at increased depths of cardiac tissue. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2009:4523-6. [PMID: 19964642 DOI: 10.1109/iembs.2009.5334106] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Recently, novel near-infrared (NIR) voltage-sensitive dyes were developed for imaging electrical activity in blood-perfused hearts and for tomographic applications. However, their usefulness for conventional surface mapping is unclear. The spectral shift to the NIR range significantly increases the penetration depth of light into the tissue, thus increasing the intramural volume contributing to the optical action potential (OAP). Here, we characterize both computationally and experimentally the effect of increased penetration depth on the OAP upstroke, the OAP component most sensitive to optical scattering and absorption, and the activation maps. Optical imaging of cardiac electrical activity was performed in isolated rat hearts (n = 5) paced from the LV mid free wall. We used the NIR dye JPW-6033 (excitation at 660nm, acquisition at >695nm). The conventional dye DI-4-ANEPPS (excitation at 532nm, acquisition at 700 DF50nm) was used for comparison. To simulate OAP we utilized a hybrid model that couples light transport equations with the model of electrical propagation. As expected, the switch from DI-4-ANEPPS to JPW-6033 significantly increased the upstroke duration: from 3.95 + or - 0.69ms to 5.39 + or - 0.82 ms, respectively. However, activation maps were largely unaffected. The correlation between the shape of the optical upstroke, and the averaged subsurface wave front orientation was also preserved. The computer simulations are in excellent agreement with the experimental data. In conclusion, our analysis suggests that despite significant increase in upstroke duration, the novel NIR dyes can be a useful alternative to conventional dyes in surface mapping applications.
Collapse
Affiliation(s)
- Richard D Walton
- Biological Sciences and members of the Multidisciplinary Cardiovascular Research Centre, University of Leeds, Leeds, LS2 9JT UK.
| | | | | | | |
Collapse
|
11
|
Plank G, Burton RAB, Hales P, Bishop M, Mansoori T, Bernabeu MO, Garny A, Prassl AJ, Bollensdorff C, Mason F, Mahmood F, Rodriguez B, Grau V, Schneider JE, Gavaghan D, Kohl P. Generation of histo-anatomically representative models of the individual heart: tools and application. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2009; 367:2257-92. [PMID: 19414455 PMCID: PMC2881535 DOI: 10.1098/rsta.2009.0056] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
This paper presents methods to build histo-anatomically detailed individualized cardiac models. The models are based on high-resolution three-dimensional anatomical and/or diffusion tensor magnetic resonance images, combined with serial histological sectioning data, and are used to investigate individualized cardiac function. The current state of the art is reviewed, and its limitations are discussed. We assess the challenges associated with the generation of histo-anatomically representative individualized in silico models of the heart. The entire processing pipeline including image acquisition, image processing, mesh generation, model set-up and execution of computer simulations, and the underlying methods are described. The multifaceted challenges associated with these goals are highlighted, suitable solutions are proposed, and an important application of developed high-resolution structure-function models in elucidating the effect of individual structural heterogeneity upon wavefront dynamics is demonstrated.
Collapse
Affiliation(s)
- Gernot Plank
- Computational Biology Group, University of Oxford, Oxford OX1 2JD, UK.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Kong W, Ideker RE, Fast VG. Transmural optical measurements of Vm dynamics during long-duration ventricular fibrillation in canine hearts. Heart Rhythm 2009; 6:796-802. [PMID: 19467507 DOI: 10.1016/j.hrthm.2009.02.028] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2008] [Accepted: 02/18/2009] [Indexed: 11/26/2022]
Abstract
BACKGROUND Knowledge of transmural V(m) changes is important for understanding the mechanism of long-duration ventricular fibrillation (LDVF). OBJECTIVE The purpose of this study was to measure transmural V(m) changes during LDVF. METHODS V(m) was recorded optically at up to 8 transmural points separated by 1.5 mm in the left ventricle of Langendorff-perfused canine hearts (n = 6) using a bundle of optical fibers (optrode) during 10 minutes of LDVF followed by 3 minutes of VF with reperfusion. Measurements were grouped into 4 layers: epicardium, subepicardium, midwall, and subendocardium. RESULTS Activation rates (ARs) and action potential durations (APDs) decreased, whereas diastolic intervals (DIs) increased during LDVF in all transmural layers (P < .05). After approximately 3 minutes of LDVF, ARs were faster and DIs shorter in the midwall and subendocardium than in the epicardium and subepicardium (P < .05). Activations persisted at the subendocardium but disappeared from other layers after approximately 8 minutes of VF in the majority of hearts. There were no transmural differences in APD during LDVF or during pacing before and after LDVF (P > .05). Restitution plots showed no functional relationship between APD and DI in any layer at any stage of LDVF. Partial reperfusion during VF for 3 minutes restored transmural synchronicity of activation and eliminated gradients in activation parameters. CONCLUSION V(m) dynamics evolve differently at different transmural layers. The subendocardium maintains persistent and the fastest activation during 10 minutes of LDVF, suggesting it contains the source of VF wavefronts. There are no transmural APD gradients and no restitution relationship between APD and DI at any transmural layer, indicating these are not the primary factors in the mechanism of LDVF.
Collapse
Affiliation(s)
- Wei Kong
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama 35294, USA
| | | | | |
Collapse
|
13
|
Trew ML, Caldwell BJ, Barbarenda Gamage TP, Sands GB, Smaill BH. Experiment-specific models of ventricular electrical activation: construction and application. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2009; 2008:137-40. [PMID: 19162612 DOI: 10.1109/iembs.2008.4649109] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Experimental intramural recordings of electrical activity at high resolution have been made in the in-vivo pig LV free wall. To analyze features of these recordings experiment-specific 3D computer models of tissue structures and electrical behavior around the recording sites were constructed. The construction of the models used novel tissue image registration, correction and feature extraction methods. Appropriate model conductivity parameters were deduced from measurements and used to replicate features of experimental recordings.
Collapse
Affiliation(s)
- Mark L Trew
- Auckland Bioengineering Institute, Department of Physiology, University of Auckland, New Zealand.
| | | | | | | | | |
Collapse
|
14
|
Kong W, Fakhari N, Sharifov OF, Ideker RE, Smith WM, Fast VG. Optical measurements of intramural action potentials in isolated porcine hearts using optrodes. Heart Rhythm 2007; 4:1430-6. [PMID: 17954403 DOI: 10.1016/j.hrthm.2007.07.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2007] [Accepted: 07/01/2007] [Indexed: 11/15/2022]
Abstract
BACKGROUND Measurements of intramural membrane potential (Vm) would greatly increase knowledge of cardiac arrhythmias and defibrillation. Optrodes offer the possibility for three-dimensional Vm mapping, but their signal quality has been inadequate. OBJECTIVE The purpose of this work was to improve optrode signal quality and use optrodes to measure intramural distribution of action potentials and shock-induced Vm changes in porcine hearts. METHODS Optrodes were made from seven optical fibers 225 or 325 microm in diameter. Fiber ends were polished at a 45 degrees angle, which improved light collection and allowed their insertion without a needle. Fluorescent measurements were performed in isolated porcine hearts perfused with Tyrode's solution or blood using Vm-sensitive dye RH-237 and a 200-W Hg/Xe lamp. RESULTS The signal-to-noise ratio for 325-microm fibers was 44 +/- 23 in blood-perfused hearts (n = 5) and 106 +/- 45 in Tyrode's-perfused hearts (n = 3), which represents an approximately four-fold improvement over previously reported data. There was close correspondence between optical and electrical measurements of activation times and action potential duration (APD). No significant intramural APD gradients were observed at cycle lengths up to 4 s and in the presence of dofetilide or d-sotalol. Application of shocks (5-50 V/cm) produced large intramural Vm changes (up to approximately 200% action potential amplitude), possibly reflecting a combined effect of tissue discontinuities and optrode geometry. CONCLUSIONS A substantial improvement of optrode signal quality was achieved. Optical measurements of APD and activation times matched electrical measurements. Optrode measurements revealed no significant intramural APD gradients. Application of shocks caused large intramural Vm changes that could be influenced by the optrode geometry.
Collapse
Affiliation(s)
- Wei Kong
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama 35294, USA
| | | | | | | | | | | |
Collapse
|
15
|
Tai DCS, Hooks DA, Harvey JD, Smaill BH, Soeller C. Illumination and fluorescence collection volumes for fiber optic probes in tissue. JOURNAL OF BIOMEDICAL OPTICS 2007; 12:034033. [PMID: 17614741 DOI: 10.1117/1.2750288] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Optical fibers can deliver light to, and collect it from, regions deep in tissue. However, reported illumination and fluorescence collection volumes adjacent to the fiber tip have been inconsistent, and systematic data on this topic are not available. Illumination and fluorescence collection profiles were characterized with high spatial resolution for different optical fibers in tissue and various fluids using two-photon flash photolysis and excitation. We confirm that illumination and fluorescence collection volumes for optical fibers are near identical. Collection volume is determined by the core dimensions and numerical aperture (NA) of the fiber and the scattering properties of the medium. For a multimode optical fiber with 100 microm core diam and NA=0.22, 80% of the total fluorescence is collected from a depth of 170 microm in tissue and 465 microm in nonscattering fluid. A semiempirical mathematical description of photon flux adjacent to the fiber tip was also developed and validated. This was used to quantify the extent of temporal blurring associated with propagation of a wavefront of altered fluorescence emission across the region addressed by fiber optic probes. We provide information that will facilitate the design of optical probes for tissue imaging or therapeutic applications.
Collapse
Affiliation(s)
- Dean C S Tai
- The University of Auckland, Bioengineering Institute and Department of Physics, Auckland, New Zealand 1001
| | | | | | | | | |
Collapse
|
16
|
Austin TM, Hooks DA, Hunter PJ, Nickerson DP, Pullan AJ, Sands GB, Smaill BH, Trew ML. Modeling cardiac electrical activity at the cell and tissue levels. Ann N Y Acad Sci 2007; 1080:334-47. [PMID: 17132793 DOI: 10.1196/annals.1380.025] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Significant tissue structures exist in cardiac ventricular tissue, which are of supracellular dimension. It is hypothesized that these tissue structures contribute to the discontinuous spread of electrical activation, may contribute to arrhythmogenesis, and also provide a substrate for effective cardioversion. However, the influences of these mesoscale tissue structures in intact ventricular tissue are difficult to understand solely on the basis of experimental measurement. Current measurement technology is able to record at both the macroscale tissue level and the microscale cellular or subcellular level, but to date it has not been possible to obtain large volume, direct measurements at the mesoscales. To bridge this scale gap in experimental measurements, we use tissue-specific structure and mathematical modeling. Our models, which can incorporate ion channel models at the cell level into the reaction-diffusion equations at the tissue level, have enabled us to consider key hypotheses regarding discontinuous activation.
Collapse
Affiliation(s)
- Travis M Austin
- Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Brown NH, Dobrovolny HM, Gauthier DJ, Wolf PD. A fiber-based ratiometric optical cardiac mapping channel using a diffraction grating and split detector. Biophys J 2007; 93:254-63. [PMID: 17416627 PMCID: PMC1914424 DOI: 10.1529/biophysj.106.101154] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Optical fiber-based mapping systems are used to record the cardiac action potential (AP) throughout the myocardium. The optical AP contains a contraction-induced motion artifact (MA), which makes it difficult to accurately measure the action potential duration (APD). MA is removed by preventing contraction with electrical-mechanical uncoupling drugs, such as 2,3-butanedione monoxime (BDM). We designed a novel fiber-based ratiometric optical channel using a blue light emitting diode, a diffraction grating, and a split photodetector that can accurately measure the cardiac AP without the need for BDM. The channel was designed based on simulations using the optical design software ZEMAX. The channel has an electrical bandwidth of 150 Hz and an root mean-square dark noise of 742 muV. The channel successfully recorded the cardiac AP from the wall of five rabbit heart preparations without the use of BDM. After 20-point median filtering, the mean signal/noise ratio was 25.3 V/V. The APD measured from the base of a rabbit heart was 134 +/- 8.4 ms, compared to 137.6 +/- 3.3 ms from simultaneous microelectrode recordings. This difference was not statistically significant (p-value = 0.3). The quantity of MA removed was also measured using the motion ratio. The reduction in MA was significant (p-value = 0.0001). This fiber-based system is the first of its kind to enable optical APD measurements in the beating heart wall without the use of BDM.
Collapse
Affiliation(s)
- Ninita H Brown
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA.
| | | | | | | |
Collapse
|
18
|
Li D, Nattel S. Pharmacological elimination of motion artifacts during optical imaging of cardiac tissues: is blebbistatin the answer? Heart Rhythm 2007; 4:627-8. [PMID: 17467632 DOI: 10.1016/j.hrthm.2007.01.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2007] [Indexed: 10/23/2022]
|
19
|
Chen X, Lal A, Riccio ML, Gilmour RF. Ultrasonically Actuated Silicon Microprobes for Cardiac Signal Recording. IEEE Trans Biomed Eng 2006; 53:1665-71. [PMID: 16916101 DOI: 10.1109/tbme.2006.877808] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In this paper, we report on ultrasonically actuated silicon thin microprobes that successfully penetrated canine cardiac tissue in vitro, and recorded the electrophysiological signals from multiple sites simultaneously within the heart wall. The penetration force--maximum force encountered by the probe during penetration--is found to reduce with increasing ultrasonic driving voltage, on both excised canine right ventricular muscle and chicken breast muscle. The rate of force decrease varies with tissue type and microprobe dimension. With ultrasonic actuation, the silicon microprobes are inserted into isolated perfused canine heart without breakage or significant buckling, under 10Vpp actuating voltage. Recordings were obtained from isolated perfused canine heart during pacing, following the induction of ventricular tachycardia, and during the transition from ventricular tachycardia to ventricular fibrillation. Local conduction velocity of 0.60 +/- 0.03 m/s was observed from the multichannel recordings from the canine right ventricular wall under epicardial pacing. The application of the ultrasonic microprobes in cardiac electrophysiology study can provide information for reconstruction of electrical wave propagation within the heart, which is important to understanding the mechanisms of cardiac arrhythmias.
Collapse
Affiliation(s)
- Xi Chen
- SonicMEMS Laboratory, School of Electrical and Computer Engineering, Cornell University, Ithaca, NY 14853, USA.
| | | | | | | |
Collapse
|
20
|
Trew ML, Caldwell BJ, Sands GB, Hooks DA, Tai DCS, Austin TM, LeGrice IJ, Pullan AJ, Smaill BH. Cardiac electrophysiology and tissue structure: bridging the scale gap with a joint measurement and modelling paradigm. Exp Physiol 2006; 91:355-70. [PMID: 16431935 DOI: 10.1113/expphysiol.2005.031054] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Significant tissue structures exist in cardiac ventricular tissue that are of supracellular dimension. It is hypothesized that these tissue structures contribute to the discontinuous spread of electrical activation, may contribute to arrhymogenesis and also provide a substrate for effective cardioversion. However, the influences of these mesoscale tissue structures in intact ventricular tissue are difficult to understand solely on the basis of experimental measurement. Current measurement technology is able to record at both the macroscale tissue level and the microscale cellular or subcellular level, but to date it has not been possible to obtain large volume, direct measurements at the mesoscales. To bridge this scale gap in experimental measurements, we use tissue-specific structure and mathematical modelling. Our models have enabled us to consider key hypotheses regarding discontinuous activation. We also consider the future developments of our intact tissue experimental programme.
Collapse
Affiliation(s)
- Mark L Trew
- Bioengineering Institute, The University of Auckland, New Zealand.
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Dosdall DJ, Huang J, Smith WM, Allred JD, Allison JS, Ideker RE. Printed circuit board electrodes for transmural cardiac mapping. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2006; 2006:3927-3930. [PMID: 17946588 DOI: 10.1109/iembs.2006.260812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Plunge needle recording techniques have provided valuable insights into transmural activation in cardiac tissue. Construction of plunge needles has been a costly and time intensive endeavor. Plunge needles constructed with standard printed circuit board (PCB) technology and methods are outlined. PCB plunge needles are less expensive in terms of raw materials and time required for construction than hypodermic stock or epoxy plunge needles. Tested PCB plunge needles recorded signals comparable to signals recorded by other plunge needles. PCB plunge needles provide an economical and rapid alternative to previously published techniques for plunge needle design.
Collapse
Affiliation(s)
- Derek J Dosdall
- Dept. of Biomed. Eng., Alabama Univ., Birmingham, AL 35294, USA.
| | | | | | | | | | | |
Collapse
|