1
|
Schäfer T, Mätzener KJ, Jung RE, Özcan M, Hjerppe J. Load-bearing capacity of screw-retained fixed dental prostheses made of monolithic zirconia on different abutment designs and abutment-free implant connection. J Dent 2025; 153:105561. [PMID: 39778736 DOI: 10.1016/j.jdent.2025.105561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2024] [Revised: 12/23/2024] [Accepted: 01/05/2025] [Indexed: 01/11/2025] Open
Abstract
OBJECTIVES A new abutment-free implant connection allows for direct screwing of FDPs on implants to avoid complications caused by cement rests or screw loosening, which may affect to screw torque and load distribution. The objective of this study was to test the initial (Fi) and final failure (Ff) loads and torque changes of abutment-free monolithic zirconia CAD-CAM fixed dental prostheses (FDPs) compared to titanium FDPs on different abutment designs. METHODS Three-unit screw-retained FDPs (n = 50) on two implants (n = 100) were divided into groups (n = 10) based on the implant-abutment connection and material of the supra-structure: (1) abutment-free monolithic CAD-CAM zirconia FDP (Abut-free-Zr), (2) abutment-free veneered titanium FDPs (Abut-free-Ti), (3) monolithic zirconia FDPs with titanium base abutments (Zr-Ti-Base), (4) monolithic zirconia FDPs on multi-unit abutments (Zr-MU), (5) veneered titanium FDP on multi-unit abutments (Ti-MU). All specimens were subjected to thermo-mechanical aging (1'200'000 Cycles, 49 N, 1.67 Hz, 5º to 50º C, dwelling time 120 s). Torque of the screws was measured, and static loading was performed. Data were tested using ANOVA and Tukey's tests (p < 0.05). RESULTS After thermo-mechanical aging, all screws showed reduced torque, Ti-MU significantly more reduction compared to Abut-Free-Ti (p = 0.0021). Titanium groups showed significantly lower Fi (N) values (171.4-230 vs 1272-1358,) due to veneering porcelain fractures (p = 0.0001) and significantly higher Ff (N) (2922 -3029 N vs. 1272-1358) values than zirconia groups (p < 0.0001). CONCLUSIONS Three-unit abutment-free monolithic zirconia FPDs showed similar failure loads compared to other zirconia groups, while the titanium groups exhibited superior final failure loads. Different abutment designs did not seem to affect the failure loads. CLINICAL SIGNIFICANCE The specific design of the novel implant interface allows for the fabrication of implant supported FDPs with personalized design directly on implant level without abutments. The monolithic zirconia FDPs on abutment-free implant connection can be used with good confidence since they exhibit similar mechanical stability as monolithic zirconia FDPs on titanium-base or multi-unit abutments.
Collapse
Affiliation(s)
- Tobias Schäfer
- Doctoral Student, Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich 8032, Switzerland
| | - Kiren J Mätzener
- Dental Technician, Clinic of Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich 8032, Switzerland
| | - Ronald E Jung
- Chairman, Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich 8032, Switzerland
| | - Mutlu Özcan
- Chairman, Clinic of Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich 8032, Switzerland
| | - Jenni Hjerppe
- Senior Research and Teaching Assistant, Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich 8032, Switzerland.
| |
Collapse
|
2
|
Roberto PFA, Luís HS, Oliveira SA. In vitro evaluation of surface roughness of titanium abutments after air polishing with different abrasive powders. Int J Dent Hyg 2025; 23:73-79. [PMID: 38852151 DOI: 10.1111/idh.12838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 05/02/2024] [Accepted: 05/04/2024] [Indexed: 06/11/2024]
Abstract
OBJECTIVES The purpose of this study was to evaluate the effects of air polishing with sodium bicarbonate and erythritol powders on surface roughness and morphological changes in titanium abutments. METHODS A total of 45 grade V titanium discs were divided in three groups: Group A (Control) air polished with air/water; Group B, air polished with sodium bicarbonate powder; and Group C, air polished with erythritol powder. After air polishing, the samples' roughness (Sa) in micrometres were analysed with an optical profilometer. The samples' surface morphology study was conducted via scanning electronic microscope (SEM). Data were described using mean and standard deviation of roughness values (Sa). Inferential analysis was performed using the ANOVA multiple comparison test followed by Tukey's post hoc test. Both tests used a 5% level of significance. RESULTS After air polishing, average roughness of group A, B and C were 0.036, 0.046 and 0.037 μm, respectively, with statistically significant differences between groups A and B (p < 0.05). No statistically significant differences were found between group A and group C, as well as between group B and C (p > 0.05). As for the morphology analysis, damages to the titanium surface were only observed in group B. CONCLUSIONS The study indicates that air polishing with erythritol powder maintains titanium abutment integrity better than sodium bicarbonate, which increased surface roughness and caused damage. Erythritol is preferable for minimizing surface alterations and maintaining morphological stability.
Collapse
Affiliation(s)
- Pedro Francisco Almeida Roberto
- Faculdade de Medicina Dentária, Rede de Higienistas Orais para o Desenvolvimento da Ciência (RHODes), Universidade de Lisboa, Lisbon, Portugal
| | - Henrique Soares Luís
- Faculdade de Medicina Dentária, Rede de Higienistas Orais para o Desenvolvimento da Ciência (RHODes), Universidade de Lisboa, Lisbon, Portugal
- Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Universidade de Lisboa, Lisbon, Portugal
- Centro de Inovação em Tecnologias e Cuidados da Saúde (ciTechCare), Politécnico de Leiria, Leiria, Portugal
| | - Sofia Arantes Oliveira
- Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Universidade de Lisboa, Lisbon, Portugal
| |
Collapse
|
3
|
Sharon E, Engel I. The Effect of Prosthetic Factors on the Long-Term Survival of Dental Implants: A Narrative Review. Oral Maxillofac Surg Clin North Am 2025; 37:25-34. [PMID: 39261213 DOI: 10.1016/j.coms.2024.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/13/2024]
Abstract
The success of implants depends on the biological and mechanical factors of the implant, as well as on the chosen prosthesis, which has different characteristics that can affect the survival of the implant and its marginal bone levels. Therefore, when choosing the type of prosthesis, it is necessary to understand and consider each of these variables and tailor them to the relevant clinical situation. In this narrative review, we will assess the types of prostheses, their different characteristics, timing, and their impact on implant survival and marginal bone levels, as accepted in today's literature.
Collapse
Affiliation(s)
- Esi Sharon
- Department of Prosthodontics, Hadassah Medical Center, Jerusalem, Israel; Faculty of Dental Medicine, Hebrew University of Jerusalem, Israel.
| | - Ilana Engel
- Department of Prosthodontics, Hadassah Medical Center, Jerusalem, Israel; Faculty of Dental Medicine, Hebrew University of Jerusalem, Israel
| |
Collapse
|
4
|
Alterman M, Casap N. The Approach to Periimplantitis. Oral Maxillofac Surg Clin North Am 2025; 37:85-97. [PMID: 39389838 DOI: 10.1016/j.coms.2024.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/12/2024]
Abstract
Peri-implant diseases require an extensive approach that includes pre-operative risk assessment, patient education on oral hygiene, and ensuring sufficient tissue support and accurate implant placement. Treatment typically starts with comprehensive decontamination using mechanical debridement, chemical agents, and advanced therapies such as laser or photodynamic therapy. Depending on the severity of the disease and the extent of bone loss, surgical strategies are adapted, ranging from less invasive access surgery in initial stages to more intensive resective or regenerative procedures in advanced cases. The following article will present a holistic and systematic approach to managing periimplantitis.
Collapse
Affiliation(s)
- Michael Alterman
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Hebrew University of Jerusalem, PO Box 12272, Jerusalem 9112102, Israel.
| | - Nardy Casap
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Hebrew University of Jerusalem, PO Box 12272, Jerusalem 9112102, Israel
| |
Collapse
|
5
|
Mohebbi H, Habibzadeh S, Alikhasi M, Mosaddad SA, Ghodsi S. The effect of fabrication procedures and thermomechanical loading on the structural properties of screw-retained metal-ceramic implant restorations: An in vitro study. J Prosthodont 2024. [PMID: 39696845 DOI: 10.1111/jopr.14008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2024] [Accepted: 12/05/2024] [Indexed: 12/20/2024] Open
Abstract
PURPOSE Metal-ceramic screw-retained implant restorations persist as a fundamental choice in specific clinical scenarios. Little is known about the effects of fabrication steps and aging on their structural properties. This study aimed to investigate how laboratory fabrication procedures and thermomechanical loading affect the structural properties of screw-retained metal-ceramic implant restorations. MATERIALS AND METHODS Ten screw-retained metal-ceramic restorations were conventionally cast using UCLA chromium-cobalt overcast abutments. After 500 cycles of thermocycling and 500,000 cycles of mechanical loading, changes in connection dimensions and rotational freedom (RF) were measured and compared at various fabrication steps and post-thermomechanical loading. A generalized estimating equations (GEE) model was employed to analyze trends across the studied time points within the fabrication stage and after thermomechanical loading, with LSD post-hoc tests applied for pairwise comparisons. The level of significance was set at α = 0.05. RESULTS Significant changes were observed across the analyzed time points: the average hexagonal side length (L) decreased (p < 0.001), and the average hexagonal angle deformation (P) increased, with notable differences observed in most comparisons between different fabrication steps (p < 0.001). Short (T1) and long (T2) diagonals of the hexagon showed downward trends (p < 0.001), while concentricity (O) and RF increased (p < 0.001), except between porcelain firing and loading steps for RF (p = 0.637). Casting had the greatest impact on variations in O (93.33%), T1 (88.88%), and T2 (45%), while porcelain firing significantly affected L (71.42%), P (71.42%), with the greatest effect on RF (75.32%). CONCLUSIONS The fabrication processes and simulated clinical use adversely impacted the structural integrity and RF of abutments in screw-retained chromium-cobalt overcast implant restorations.
Collapse
Affiliation(s)
- Hosein Mohebbi
- Department of Prosthodontics, Faculty of Dentistry, AJA University of Medical Sciences, Tehran, Iran
| | - Sareh Habibzadeh
- Dental Research Center, Dentistry Research Institute, Department of Prosthodontics, School of Dentistry, International Campus, Tehran University of Medical Sciences, Tehran, Iran
| | - Marzieh Alikhasi
- Dental Research Center, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran
| | - Seyed Ali Mosaddad
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
- Department of Conservative Dentistry and Bucofacial Prosthesis, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain
| | - Safoura Ghodsi
- Dental Research Center, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
6
|
Kwan JC. A Biomechanical Comparative Analysis of Abutment Screw Head Designs on Preload Stability Under Oblique Compressive Forces: An In Vitro Pilot Study. J ORAL IMPLANTOL 2024; 50:617-625. [PMID: 39410828 DOI: 10.1563/aaid-joi-d-24-00128] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2024]
Abstract
The purpose of this study was to examine the impact of abutment screw head sizes on preload stability when secured to a standard external hex implant under oblique compressive forces. Fifteen metal crowns were divided into 3 equal groups. The first group had 5 angulated cemented crowns connected to a 3-mm-tall straight hexagonal abutment with an external hex abutment screw. The second and third groups each had 5 straight cemented crowns attached to a tapered abutment with flat-slotted and internal hex abutment screws, respectively. Samples were subjected to a static cyclic load until failure. Kruskal-Wallis H, Dunn, and one-way analysis of variance with Tukey honestly significant difference tests were performed. Cemented straight crowns supported by an angled abutment connected to implants with flat-slotted and internal hex abutment screw heads failed at an average of 4.24 × 106 cycles ± 3.31 SD and 12.67 × 106 cycles ± 5.47 SD, respectively. Cemented angled crowns supported by a straight abutment connected to identical implants with an external hex abutment screw survived 18.02 × 106 cycles ± 4.49 SD. The periotest value rate of change increased at a higher rate in crowns supported by angled abutments compared with straight abutments (p < .05). No cement failure was observed. Under the experimental conditions, larger abutment screw head sizes demonstrated greater stability of the abutment-abutment screw joint interface. Based on the in vitro findings, no cement failure was observed between the cemented crown and abutment connection. Future research with standardized comparative setups and larger sample sizes is needed.
Collapse
Affiliation(s)
- Jan C Kwan
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal
| |
Collapse
|
7
|
Schoenbaum TR, Papaspyridakos P, Kim YK, Arce C, Knoernschild K. Clinician preferences for single-unit implant restoration designs and materials: A survey of the membership of the Pacific Coast Society for Prosthodontics. J Prosthet Dent 2024; 132:1288-1298. [PMID: 36935268 DOI: 10.1016/j.prosdent.2023.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 02/15/2023] [Accepted: 02/16/2023] [Indexed: 03/19/2023]
Abstract
STATEMENT OF PROBLEM Clinical research has difficulty keeping pace with the rapid evolution of materials, protocols, and designs of single-unit implant restorations. The clinical design preferences of prosthodontics for different clinical scenarios are lacking. PURPOSE The purpose of this cross-sectional survey was to determine the current prevalence of usage of various treatment options and materials for single-unit implant-supported restorations. MATERIAL AND METHODS From August to September of 2022, a survey invitation was sent to members of the Pacific Coast Society for Prosthodontics (PCSP). The survey was hosted online and asked 37 questions related to the materials, protocols, and design preferences for single-unit implant-supported restorations in various clinical scenarios. The prompts included the suggestion that answers should be based on preferences for the "ideal" treatment of a hypothetical patient seeking implant treatment for the replacement of a single missing tooth. RESULTS Of 133 questionnaires sent via email, 35 were returned. The results are presented with histograms that use color coding as an experience proxy metric. A total of 87% of respondents was in private practice, and 60% reported having restored more than 1000 single-unit implant restorations. For the replacement of a single maxillary central incisor under ideal conditions and angulation through the palatal surface, respondents preferred bone level implants (93%) and screw-retained restorations (80%), with 50% of those being zirconia with a titanium abutment and 21% being cast metal-ceramic. For an identical scenario, except that the angulation would be through the facial surface, respondents preferred the angled screw system (55%) and cemented (41%) restorations. For the replacement of a single missing mandibular molar under ideal conditions, respondents preferred bone level implants (79%) and screw-retained restorations (79%), with 70% of those being zirconia with a titanium abutment and 17% being cast metal-ceramic. CONCLUSIONS While a wide range of protocols, designs, and materials exist for the replacement of a single missing tooth, these results provide a snapshot of current single-unit implant prosthodontic preferences in the Western United States and Canada.
Collapse
Affiliation(s)
- Todd R Schoenbaum
- Professor, Department of Restorative Sciences, Dental College of Georgia at Augusta University, Augusta, Ga.
| | - Panos Papaspyridakos
- Associate Professor, Department of Prosthodontics, Tufts School of Dental Medicine, Boston Mass
| | - Young K Kim
- Clinical Assistant Professor, Department of Prosthodontics, New York University, New York, NY
| | - Celin Arce
- Assistant Professor, Department of Restorative Sciences, University of Alabama at Birmingham, Birmingham, Ala
| | - Kent Knoernschild
- Professor, Department of Restorative Sciences, Dental College of Georgia at Augusta University, Augusta, Ga
| |
Collapse
|
8
|
Deepika K, Bhatnagar A, Singh A, Soni R. Evaluation of active tactile sensibility in a single-tooth implant opposing a natural tooth with either an immediate or delayed functional loading protocol: A parallel design clinical study. J Prosthet Dent 2024; 132:1270-1276. [PMID: 36621356 DOI: 10.1016/j.prosdent.2022.11.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 11/24/2022] [Accepted: 11/28/2022] [Indexed: 01/07/2023]
Abstract
STATEMENT OF PROBLEM High primary stability makes immediate loading more predictable, but immediately loaded implants are subjected to higher stresses and strains during the healing phase than implants that are left to heal for 3 months. Whether an earlier sensory-motor phenomenon with an immediate loading protocol helps to reduce the risk of overloading at the implant-bone interface is unclear. PURPOSE The purpose of this concurrent parallel design clinical study was to evaluate and compare active tactile sensibility for a single-tooth implant opposing a natural tooth in the mandibular posterior region with either a delayed or immediate functional loading -protocol. MATERIAL AND METHODS In this parallel group randomized trial, 2 test groups were formed: the DL group comprised 20 participants with the delayed loading protocol (loading after 3 months), and the IL group comprised 20 participants with the immediate loading protocol (loading within 2 days). Natural tooth-to-tooth contact on the side contralateral to the implant site (split mouth) in both test groups was used as a control to evaluate active tactile sensibility, which was evaluated in the test and control sites of both groups by using interocclusal articulating foils of varying thickness in maximum intercuspation. Active tactile sensibility was compared between the DL and IL groups at 3 and 6 months of follow-up. The nonparametric Mann-Whitney test was used for intergroup comparisons (P=.05). RESULTS A significant difference was found for 8-μm- and 12-μm-thick articulating foil at 3 months and for 8-μm-thick foil at 6 months (P<.05), indicating a difference in active tactile sensibility between the DL and IL groups. No implant failure was recorded in this short clinical study. CONCLUSIONS An immediate loading protocol can be performed in implants with sufficient primary stability. Upon loading, the IL group has shown more active tactile perception than the DL group.
Collapse
Affiliation(s)
- Kumari Deepika
- Senior Resident, Department of Prosthodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India.
| | - Atul Bhatnagar
- Professor, Unit of Prosthodontics, Faculty of Dental Sciences, Institute of Medical Sciences, Banaras Hindu University, Varanasi, UP, India
| | - Ankita Singh
- Associate Professor, Unit of Prosthodontics, Faculty of Dental Sciences, Institute of Medical Sciences, Banaras Hindu University, Varanasi, UP, India
| | - Romesh Soni
- Professor, Unit of Prosthodontics, Faculty of Dental Sciences, Institute of Medical Sciences, Banaras Hindu University, Varanasi, UP, India
| |
Collapse
|
9
|
Kondo Y, Sakai K, Minakuchi H, Horimai T, Kuboki T. Implant-supported fixed prostheses with cantilever: a systematic review and meta-analysis. Int J Implant Dent 2024; 10:57. [PMID: 39570465 PMCID: PMC11582258 DOI: 10.1186/s40729-024-00573-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2024] [Accepted: 10/28/2024] [Indexed: 11/22/2024] Open
Abstract
PURPOSE This systematic review (SR) aimed to investigate whether the presence of a cantilever affects the results of implant treatment for partial edentulism, including an analysis of the anterior and posterior regions of the dental arches. METHODS An electronic search was performed, and original articles published between 1995 and November 2023 were included. The outcomes were the implant survival rate, patient satisfaction, occurrence of mechanical complications, and marginal bone loss around the implants. Two SR members independently examined the validity of the studies, extracted evidence from the included studies, and performed risk of bias assessment, comprehensive evidence evaluation, and meta-analysis. RESULTS Nine studies met our inclusion criteria. Implant survival rate tended to be lower in the cantilever group, and marginal bone loss tended to be higher in the cantilever group; however, there was no significant difference. There was no significant difference in patient satisfaction based on the presence or absence of a cantilever. Moreover, the incidence of mechanical complications was significantly higher in the cantilever group. According to the analysis of anterior and posterior regions, implant survival rate tended to be lower in the cantilever group of the posterior region, and marginal bone loss around the implants tended to be higher in the cantilever group of the anterior region. CONCLUSION Implant-supported fixed prostheses with cantilevers did not negatively affect implant survival rate, marginal bone loss, or patient satisfaction. However, the incidence of mechanical complications significantly increased in the cantilever group.
Collapse
Affiliation(s)
- Yusuke Kondo
- Clinical Guideline Task-Force Members (2018-), Japanese Society of Oral Implantology (JSOI), Tokyo, Japan.
- Division of Oral Reconstruction and Rehabilitation, Kyushu Dental University, Kitakyushu, Japan.
| | - Kiyoshi Sakai
- Clinical Guideline Task-Force Members (2018-), Japanese Society of Oral Implantology (JSOI), Tokyo, Japan
- Department of Oral and Maxillofacial Surgery, Nagoya University Hospital, Nagoya, Japan
| | - Hajime Minakuchi
- Clinical Guideline Task-Force Members (2018-), Japanese Society of Oral Implantology (JSOI), Tokyo, Japan
- Department of Oral Rehabilitation and Implantology, Okayama University Hospital, Okayama, Japan
| | - Takuya Horimai
- The Library, School of Dentistry, Nihon University, Tokyo, Japan
| | - Takuo Kuboki
- Committee Members for Research Planning and Promotion (2020-2021), JSOI, Tokyo, Japan
- Committee Members for Research Planning and Promotion (2022-2023), JSOI, Tokyo, Japan
- Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Faculty of Medicine Dentistry and Pharmaceutical Sciences, Okayama, Japan
| |
Collapse
|
10
|
Guo J, Wang X, Liu Z, Zhou J, Wang L. Acoustic resonance frequency analysis for evaluating prosthetic screw stability in splinted implant-supported fixed dental prostheses: An in vitro study. J Prosthet Dent 2024:S0022-3913(24)00723-6. [PMID: 39550228 DOI: 10.1016/j.prosdent.2024.10.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2024] [Revised: 10/26/2024] [Accepted: 10/29/2024] [Indexed: 11/18/2024]
Abstract
STATEMENT OF PROBLEM Prosthetic screw loosening is a common mechanical complication of implant-supported fixed dental prostheses. Although techniques for detecting screw loosening in single implant-supported fixed dental prostheses have been reported, studies on the screw stability for splinted implant-supported fixed dental prostheses are lacking. PURPOSE The purpose of this in vitro study was to determine whether acoustic resonance frequency analysis using a newly developed system could detect prosthetic screw loosening in splinted implant-supported fixed dental prostheses. MATERIAL AND METHODS Maxillary and mandibular edentulous gypsum casts with screw-retained definitive fixed dental prostheses supported by 6 implants were used. A tapping simulation (0.2 N, 50 Hz) was directly applied to the buccal side of the tested screw, and a pickup device was used to collect the acoustic signals. The resonance peak frequencies of these signals were extracted by using time-frequency-domain analysis based on short-time Fourier transform. A 2-way mixed analysis of variance was performed to evaluate how jaw position and insertion torque affect resonance peak frequency. The Pearson correlation analysis was used to assess the relationship between the insertion torque and resonance peak frequency for each screw (α=.05). RESULTS Deviation from the insertion torque resulted in significant changes in the resonance peak frequency within 6 to 9 kHz. Additionally, significant positive correlation between the insertion torques and resonance peak frequencies was observed for all screws (P<.05). This correlation was affected by the position of the screw within the prosthesis. Specifically, screw loosening in the posterior and anterior regions had a greater influence on the resonance peak frequency than that in the central region. CONCLUSIONS The acoustic resonance peak frequency shifted leftward as the screw preload torque decreased, indicating a significant correlation with screw stability. These results suggest that acoustic resonance frequency analysis can be used to detect the stability status of a single prosthetic screw in a splinted implant-supported fixed dental prosthesis conveniently and with high sensitivity.
Collapse
Affiliation(s)
- Jiaer Guo
- Resident, Department of Oral Implantology, Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, PR China
| | - Xiaolu Wang
- Doctoral student, Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, PR China
| | - Zhixin Liu
- Resident, Department of Oral Implantology, Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, PR China
| | - Jianying Zhou
- Professor, State Key Laboratory of Optoelectronic Materials & Technology, School of Physics, Sun Yat-sen University, Guangzhou, PR China
| | - Lin Wang
- Associate Professor, Department of Oral Implantology, Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, PR China.
| |
Collapse
|
11
|
Chiam SY, Liu HP, Oh WS. Mechanical and biological complications of angled versus straight screw channel implant-supported prostheses: A systematic review and meta-analysis. J Prosthet Dent 2024:S0022-3913(24)00700-5. [PMID: 39550227 DOI: 10.1016/j.prosdent.2024.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2024] [Revised: 09/26/2024] [Accepted: 10/04/2024] [Indexed: 11/18/2024]
Abstract
STATEMENT OF PROBLEM Scientific evidence to determine the clinical performance of angled screw channel (ASC) versus straight screw channel (SC) implant-supported prostheses is lacking. PURPOSE This systematic review and meta-analysis investigated the mechanical and biological complications of ASC compared with those of SC implant-supported prostheses. MATERIAL AND METHODS A systematic search was conducted by following the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guideline in the PubMed, Embase, and Web of Science databases and was supplemented with a manual search for clinical studies reporting the mechanical and biological complications of ASC compared with those of SC implant-supported prostheses. The search was focused on porcelain fracture, screw loosening or fracture, marginal bone loss (MBL), and pink esthetic score (PES). The data were extracted from selected articles and compounded to estimate the complications with a 95% confidence interval (CI) using a random effects meta-analysis. The publication bias was assessed using the Cochrane Risk of Bias and Newcastle-Ottawa Scale (α=.05). RESULTS A total of 4217 records were identified, and 14 studies were selected for quantitative synthesis of 629 participants with 658 ASC and 166 SC implant-supported prostheses. The meta-analyses of comparative studies showed no statistically significant difference in mechanical complications between ASC and SC prostheses, with odds ratio (OR) of 1.75 (95% CI=0.71-4.34, P=.224). Porcelain fracture and screw loosening were the most common complications with ASC prostheses. In addition, no statistically significant difference was found between ASC and SC prostheses in the MBL (mean difference=-0.07, 95% CI=-0.15-0.01, P=.077) and PES (mean difference=-0.19, 95% CI=-0.90-0.52, P=.593). CONCLUSIONS The clinical performance of ASC may be comparable with that of SC implant-supported prostheses in terms of mechanical and biological complications. However, the moderate level of evidence necessitates further research to validate these findings.
Collapse
Affiliation(s)
- Sieu Yien Chiam
- Clinical Assistant Professor, Department of Biologic and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich.
| | - Han-Pang Liu
- Postgraduate student, Department of Oral Medicine and Periodontics, University of Michigan School of Dentistry, Ann Arbor, Mich
| | - Won-Suk Oh
- Clinical Professor, Department of Biologic and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich
| |
Collapse
|
12
|
Tajti P, Solyom E, Czumbel LM, Szabó B, Fazekas R, Németh O, Hermann P, Gerber G, Hegyi P, Mikulás K. Monolithic zirconia as a valid alternative to metal-ceramic for implant-supported single crowns in the posterior region: A systematic review and meta-analysis of randomized controlled trials. J Prosthet Dent 2024; 132:881-889. [PMID: 37349158 DOI: 10.1016/j.prosdent.2023.05.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 05/18/2023] [Accepted: 05/19/2023] [Indexed: 06/24/2023]
Abstract
STATEMENT OF PROBLEM Technical complication rates of standard metal-ceramic implant-supported posterior restorations are relatively high. Whether monolithic zirconia crowns represent a more successful alternative is unclear. PURPOSE The purpose of this systematic review and meta-analysis was to compare the clinical outcomes of posterior monolithic zirconia and metal-ceramic implant-supported single crowns. MATERIAL AND METHODS A search was conducted in MEDLINE, Scopus, Embase, Web of Science, and CENTRAL databases for randomized controlled trials up to April 2023 with a follow-up time of at least 1 year. Restoration and implant survival and failure rates, marginal bone loss (MBL), bleeding on probing (BOP), and technical complications were analyzed by 2 reviewers. Statistical analyses were conducted using the R-statistics software program. The risk of bias was assessed by the Cochrane Risk of Bias Tool 2 (RoB 2), and the certainty of evidence by the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach. RESULTS A total of 11 out of 2030 records were identified by title and abstract, and 4 records were included after full-text analysis. The statistical analysis revealed no significant difference in MBL (MD -0.11, 95% CI: [-0.25; 0.03]), BOP (OR 0.66, 95% CI: [0.25; 1.77]), or implant failure (OR 1.30, 95% CI: [0.24; 7.08]). Monolithic zirconia presented significantly less chipping over 1 year (OR 0.17, 95% CI: [0.03; 0.99]). The chipping rate was 0% for monolithic zirconia and 7.61% for metal-ceramic. Based on a narrative review, the restoration survival rate was 97.5% in the monolithic zirconia group and 99.1% in the metal-ceramic group. CONCLUSIONS Monolithic zirconia showed favorable short-term survival rates and had significantly less chipping over 1 year. Regarding MBL, BOP, and failure rates, both restoration types presented similar results at the 1-year follow-up.
Collapse
Affiliation(s)
- Péter Tajti
- Resident, Department of Prosthodontics, Semmelweis University, Budapest, Hungary; PhD student, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Eleonora Solyom
- Clinical Specialist, Department of Periodontology, Semmelweis University, Budapest, Hungary; PhD student, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - László Márk Czumbel
- Resident, Department of Periodontology, Semmelweis University, Budapest, Hungary; Scientific Methodology Supervisor, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Bence Szabó
- Biostatistician, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Réka Fazekas
- Assistant Professor, Department of Conservative Dentistry, Semmelweis University, Budapest, Hungary; Supervisor, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Orsolya Németh
- Director, Associate Professor, Department of Community Dentistry, Semmelweis University, Budapest, Hungary; Supervisor, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Péter Hermann
- Director, Full Professor, Department of Prosthodontics, Semmelweis University, Budapest, Hungary; Supervisor, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Gábor Gerber
- Associate Professor, Department of Anatomy, Histology and Embryology, Semmelweis University, Budapest, Hungary; Supervisor, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Péter Hegyi
- Strategic Director, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Strategic Director, Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Krisztina Mikulás
- Assistant Professor, Department of Prosthodontics, Semmelweis University, Budapest, Hungary; Supervisor, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary.
| |
Collapse
|
13
|
Naumann M, Happe A, Holtkamp A, Blender SM. Monolithic Hybrid Abutment Crowns (Screw-Retained) Versus Monolithic Hybrid Abutments With Monolithic Crowns (Adhesively Cemented): Three-Year Data of a Prospective Clinical Split-Mouth Study. J ESTHET RESTOR DENT 2024. [PMID: 39460507 DOI: 10.1111/jerd.13335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2024] [Revised: 09/28/2024] [Accepted: 09/30/2024] [Indexed: 10/28/2024]
Abstract
OBJECTIVES This study compares the restoration of single-tooth implants with screw-retained lithium-disilicate hybrid-abutment crowns and single-tooth lithium-disilicate crowns adhesively bonded to hybrid abutments with regard to objective clinical and subjective patient-specific evaluation criteria over a time of observation of 3 years. MATERIALS AND METHODS Two bone-level implants were placed in contralateral sides of the same jaw in 10 patients, each with two single-tooth gaps. After osseointegration, implants were uncovered and an impression was taken. In accordance with the split-mouth design, one implant in each patient was restored with a screw-retained hybrid abutment crown and the other implant with a hybrid abutment and an adhesively bonded single-tooth crown. The restorations were randomly allocated to the implants. Prefabricated titanium bases were used. The ceramic abutments and restorations were fabricated monolithically with pressed lithium-disilicate ceramic. An objective evaluation (survival, technical, or biological complications, FIPS) by the practitioner and a subjective evaluation (satisfaction, OHIP) by the patient were carried out after 3, 6, 12, 24, and 36 months after restoration placement. RESULTS Both restoration types showed a survival rate of 100% after 3 years of observation. No technical or biological complications occurred. No significant difference was observed between the two types of restoration neither for objective (survival, technical or biological complications, FIPS) nor subjective (satisfaction, OHIP) evaluation criteria (p > 0.05). CONCLUSION No statistically significant differences were observed between screw-retained and cemented pressed lithium-disilicate restorations on bone-level implants for both objective and subjective evaluation criteria, respectively. CLINICAL SIGNIFICANCE Monolithic hybrid-abutment crowns (screw-retained) and monolithic hybrid abutments with single-tooth crowns (cemented) made of pressed lithium disilicate can be used to successfully restore single implants.
Collapse
Affiliation(s)
- Michael Naumann
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Berlin, Germany
- Private Practice, Stahnsdorf, Germany
| | - Arndt Happe
- Center of Dentistry, Department of Prosthetic Dentistry, Ulm University Hospital, Ulm, Germany
- Private Practice, Dr. Happe&Kollegen, Münster, Germany
| | - Agnes Holtkamp
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Sarah M Blender
- Center of Dentistry, Department of Prosthetic Dentistry, Ulm University Hospital, Ulm, Germany
| |
Collapse
|
14
|
Ji F, Shim JS, Lee J, Oh H, Ryu JJ. Effect of crown seating methods on the remnant cement in the subgingival region of a cement-retained implant crown. Sci Rep 2024; 14:24249. [PMID: 39414886 PMCID: PMC11484903 DOI: 10.1038/s41598-024-73806-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Accepted: 09/20/2024] [Indexed: 10/18/2024] Open
Abstract
This study aimed to investigate the effects of crown seating speed, crown seating force, quantity of cement used, and type of implant cement on the amount of remnant cement in the subgingival region (RCS) after cementation. Cement-retained implant crowns were cemented to titanium abutments using the following methods: four types of implant cement (TBN: TEMP BOND NE, NR: NEXUS RMGI, ME: MAXCEM ELITE, and U200: RELYX U200), three quantities of cement (0.02 ml, 0.04 ml, and 0.06 ml), three crown seating speeds (5 mm/s, 10 mm/s, and 15 mm/s), and two crown seating forces (25 N, 50 N). The surface area and length of the RCS were measured using a 3D intraoral scanner. The total RCS weight was measured using an analytical balance. The RCS increased significantly as the seating speed increased, the seating force increased, and the quantity of cement increased (p < 0.05). The RCS values were the highest for TBN, followed by U200, NR, and ME (p < 0.05). The lower seating speed, smaller quantity of cement used, and smaller seating force applied in cement-retained implant restorations minimized the RCS in cement-retained prostheses. The type of cement is a factor that determines the aspects of the RCS.
Collapse
Affiliation(s)
- Fanghui Ji
- Korea University Graduate School, Medicine, Seoul, Republic of Korea
| | - Ji Suk Shim
- Department of Dentistry, Korea University Guro Hospital, Seoul, Republic of Korea
| | - Jeongyol Lee
- Department of Dentistry, Korea University Guro Hospital, Seoul, Republic of Korea
| | - Hwiseong Oh
- Department of Dentistry, Korea University Anam Hospital, Seoul, Republic of Korea.
| | - Jae Jun Ryu
- Korea University Graduate School, Medicine, Seoul, Republic of Korea.
| |
Collapse
|
15
|
Kim YK, Conejo J, Wagner DJ, Britton E, Schoenbaum TR. Contemporary Rationales for Cemented Implant Restorations in the Esthetic Zone. J ESTHET RESTOR DENT 2024. [PMID: 39395015 DOI: 10.1111/jerd.13330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Revised: 09/20/2024] [Accepted: 09/23/2024] [Indexed: 10/14/2024]
Abstract
OBJECTIVE This article explores the ongoing relevance of cement-retained implant restorations, focusing on their contemporary rationales for their successful use. Comprehensive considerations include esthetic, positional, and occlusal factors alongside recent technological advancements designed to mitigate previous known challenges. OVERVIEW In certain clinical scenarios, cement-retained implant restorations offer distinct advantages such as eliminating access holes for improved esthetics, particularly for malpositioned implants. Modern advancements in materials and techniques have enhanced their predictability, safety, and overall outcomes while minimizing biological risks. CONCLUSIONS When performed within appropriate protocols, cement-retained implant restorations can effectively address diverse clinical challenges. Recent technical advancements further bolster their utility, supporting esthetic, technical, biomechanical, and biological outcomes in implant rehabilitation of the partially edentulous esthetic zone. CLINICAL SIGNIFICANCE Understanding the justifications and guidelines for cement-retained implant restorations, along with recent technological advancements, enables clinicians to optimize treatment outcomes with greater flexibility while minimizing common limitations in practice.
Collapse
Affiliation(s)
- Young K Kim
- Department of Prosthodontics, New York University College of Dentistry, New York, New York, USA
| | - Julián Conejo
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, Pennsylvania, USA
| | - David J Wagner
- Private Practice Limited to Restorative and Aesthetic Dentistry, West Hollywood, California, USA
| | - Eduardo Britton
- Department of general dentistry, Dental College of Georgia, Augusta, Georgia, USA
| | - Todd R Schoenbaum
- Department of general dentistry, Dental College of Georgia, Augusta, Georgia, USA
- Department of restorative sciences, Dental Collage of Georgia, Georgia, USA
| |
Collapse
|
16
|
Yıldız P, Alkan Demetoğlu G, Talay Çevlik E. Effect of cement type on vertical marginal discrepancy and residual excess cement in screwmentable and cementable implant-supported monolithic zirconia crowns. Odontology 2024; 112:1221-1230. [PMID: 38634968 DOI: 10.1007/s10266-024-00938-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Accepted: 04/10/2024] [Indexed: 04/19/2024]
Abstract
The purpose of this study was to investigate the vertical marginal discrepancy (VMD) and residual excess cement (REC) of cementable and screwmentable monolithic zirconia crowns cemented with different types of cement. Abutments were attached to 40 implant analogues. Crowns were created using computer-aided design/computer-aided manufacturing technology from monolithic zirconia blocks, either with or without a screw access hole (SAC). Crowns created both ways were split into two groups and cemented with resin and zinc polycarboxylate cement under a 5-kg weight. VMD and REC values were evaluated using an X20 zoom stereomicroscope. Data were analysed using two-way ANOVA and the Bonferroni test. According to the two-way ANOVA results, REC measurements differed significantly in the crown design and cement groups. However, whilst VMD values were significantly different in both crown design groups, there was no significant difference in the cement groups. According to the Bonferroni test results, the highest REC (157.241 ± 44.29 µm) and VMD (68.052 ± 16.19 µm) values were found in the crowns without SAC and cemented with zinc polycarboxylate. Screwmentable crowns are more effective than cementable crowns in reducing REC and VMD. Whilst polycarboxylate cement reduces VMD in screwmentable crowns, resin cement is more suitable for cementable crowns.
Collapse
Affiliation(s)
- Pınar Yıldız
- Nimet Bayraktar Oral and Dental Health Center, Hürriyet Mah. Kılıçkaya Cad., Kayseri, Türkiye.
| | - Göknil Alkan Demetoğlu
- Department of Prosthodontics, Faculty of Dentistry, Aydın Adnan Menderes University, Hasanefendi Mahallesi, Hastane Cd. No:1, Aydın, Türkiye
| | - Esra Talay Çevlik
- Department of Prosthodontics, Faculty of Dentistry, Aydın Adnan Menderes University, Hasanefendi Mahallesi, Hastane Cd. No:1, Aydın, Türkiye
| |
Collapse
|
17
|
Bukhari A, Dahshan S, Kotina E, Zhao N, Almujel S, Gallucci GO, Hamilton A. Application of 3D printed guide for locating screw access channels in cement-retained complete arch implant-supported zirconia restorations. J Prosthet Dent 2024; 132:695-702. [PMID: 36959002 DOI: 10.1016/j.prosdent.2022.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Revised: 08/03/2022] [Accepted: 08/04/2022] [Indexed: 03/25/2023]
Abstract
Removal of cement-retained complete arch implant-supported zirconia restorations can be challenging. A predictable and minimally invasive technique combining cone beam computed tomography (CBCT) and intraoral scans with a virtual implant planning software program is described to identify the location of the screw access channels during the retrieval, thus minimizing damage to the existing restoration and allowing reuse.
Collapse
Affiliation(s)
- Asmaa Bukhari
- Demonstrator, Department of Prosthodontics, King Abdulaziz University, Jeddah, Saudi Arabia; AGE Implant program, Harvard School of Dental Medicine, Boston, Mass.
| | - Samantha Dahshan
- AGE Implant program, Harvard School of Dental Medicine, Boston, Mass
| | - Elli Kotina
- ITI Scholar Implant program, Harvard School of Dental Medicine, Boston, Mass
| | - Na Zhao
- AGE Implant program, Harvard School of Dental Medicine, Boston, Mass
| | - Saad Almujel
- Demonstrator, Department of Prosthodontics, King Saud University, Riyadh, Saudi Arabia; AGE Implant program, Harvard School of Dental Medicine, Boston, Mass
| | - German O Gallucci
- Associate Professor and Chairman, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Mass
| | - Adam Hamilton
- Discipline Lead in Prosthodontics and Graduate Program Convenor University of Western Australia Dental School, Nedland, Western Australia, Australia; Lecturer, Division of Regenerative and Implant Science, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Mass
| |
Collapse
|
18
|
Strasding M, Marchand L, Merino E, Zarauz C, Pitta J. Material and abutment selection for CAD/CAM implant-supported fixed dental prostheses in partially edentulous patients - A narrative review. Clin Oral Implants Res 2024; 35:984-999. [PMID: 38864592 DOI: 10.1111/clr.14315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 05/15/2024] [Accepted: 05/27/2024] [Indexed: 06/13/2024]
Abstract
Restorative material selection has become increasingly challenging due to the speed of new developments in the field of dental material science. The present narrative review gives an overview of the current indications for implant abutments and restoration materials for provisional and definitive implant-supported fixed dental prostheses in partially edentulous patients. For single implant restorations, titanium base abutments for crowns are suggested as an alternative to the conventional stock- and customized abutments made out of metal or zirconia. They combine the mechanical stability of a metallic connection with the esthetic potential of ceramics. For multiple-unit restorations, conical titanium bases especially designed for bridges are recommended, to compensate for deviating implant insertion axes and angulations. Even though titanium base abutments with different geometries and heights are available, certain clinical scenarios still benefit from customized titanium abutments. Indications for the definitive material in fixed implant restorations depend on the region of tooth replacement. In the posterior (not esthetically critical) zone, ceramics such as zirconia (3-5-Ymol%) and lithium-disilicate are recommended to be used in a monolithic fashion. In the anterior sector, ceramic restorations may be buccally micro-veneered for an optimal esthetic appearance. Lithium-disilicate is only recommended for single-crowns, while zirconia (3-5-Ymol%) is also recommended for multiple-unit and cantilever restorations. Attention must be given to the specific mechanical properties of different types of zirconia, as some feature reduced mechanical strengths and are therefore not indicated for all regions and restoration span lengths. Metal-ceramics remain an option, especially for cantilever restorations.
Collapse
Affiliation(s)
- Malin Strasding
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Laurent Marchand
- Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA
| | - Elizabeth Merino
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Cristina Zarauz
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - João Pitta
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
19
|
Rella E, De Angelis P, Papetti L, Damis G, Gasparini G, D'Addona A, Manicone PF. Comparison of Aesthetic, Mechanical Outcome, and Bone Loss in Angulated Screw Channels (ASCs) and Cement-Retained Implant-Supported Prosthesis: A Case-Control Study. Dent J (Basel) 2024; 12:233. [PMID: 39195077 DOI: 10.3390/dj12080233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Revised: 07/09/2024] [Accepted: 07/12/2024] [Indexed: 08/29/2024] Open
Abstract
Angulated-screw channels (ASCs) allow the clinician to employ screw-retained restorations in almost all cases, as the access hole can be moved away from the vestibular portion of the crown, where it would jeopardize the final esthetic result. The objective of this study was to compare screw-retained restorations employing ASCs with restorations cemented on angled abutments. In this study, 30 subjects, equally divided into two groups: group 1 (cemented restorations on angulated abutments) and group 2 (screw-retained restorations adopting ASCs), were treated and retrospectively compared after 2 years using the pink esthetic score (PES) and the white esthetic score (WES). All restorations were in use at the last follow-up, with a survival rate of 100%. Three mechanical complications were observed (2 chippings and 1 crown came loose), with a success rate of 93% in group 1 and 87% in group 2 (p > 0.05). No statistically significant differences were reported regarding the esthetic outcome; the marginal bone loss (MBL) showed better results for the screw-retained restorations, both at the distal aspect (group 1 = 0.98 mm ± 0.16; group 2 = 0.45 mm ± 0.06; p = 0.006) and at the mesial aspect (group 1 = 1.04 ± 0.27; group 2 = 0.45 ± 0.005; p < 0.001). From an esthetical perspective, screw-retained restorations with ASCs and cemented restorations on angulated abutments are both effective means of restoring implants; both have excellent esthetic outcomes, but screw-retained restorations have reduced bone loss when compared to cemented ones but are more prone to mechanical complications. Still, our results must be cautiously observed given the reduced dimension of our sample. Larger studies are needed to confirm our findings.
Collapse
Affiliation(s)
- Edoardo Rella
- Division of Oral Surgery and Implantology, Department of Head and Neck, Oral Surgery, and Implantology Unit, Institute of Clinical Dentistry, IRCSS "A. Gemelli" Foundation, Catholic University of the Sacred Heart, 00168 Rome, Italy
| | - Paolo De Angelis
- Division of Oral Surgery and Implantology, Department of Head and Neck, Oral Surgery, and Implantology Unit, Institute of Clinical Dentistry, IRCSS "A. Gemelli" Foundation, Catholic University of the Sacred Heart, 00168 Rome, Italy
| | - Laura Papetti
- Division of Oral Surgery and Implantology, Department of Head and Neck, Oral Surgery, and Implantology Unit, Institute of Clinical Dentistry, IRCSS "A. Gemelli" Foundation, Catholic University of the Sacred Heart, 00168 Rome, Italy
| | - Giovanni Damis
- Division of Oral Surgery and Implantology, Department of Head and Neck, Oral Surgery, and Implantology Unit, Institute of Clinical Dentistry, IRCSS "A. Gemelli" Foundation, Catholic University of the Sacred Heart, 00168 Rome, Italy
| | - Giulio Gasparini
- Maxillo-Facial Surgery Unit, IRCSS "A. Gemelli" Foundation, Catholic University of the Sacred Heart, 00168 Rome, Italy
| | - Antonio D'Addona
- Division of Oral Surgery and Implantology, Department of Head and Neck, Oral Surgery, and Implantology Unit, Institute of Clinical Dentistry, IRCSS "A. Gemelli" Foundation, Catholic University of the Sacred Heart, 00168 Rome, Italy
| | - Paolo Francesco Manicone
- Division of Oral Surgery and Implantology, Department of Head and Neck, Oral Surgery, and Implantology Unit, Institute of Clinical Dentistry, IRCSS "A. Gemelli" Foundation, Catholic University of the Sacred Heart, 00168 Rome, Italy
| |
Collapse
|
20
|
Ceddia M, Romasco T, Comuzzi L, Cipollina A, Piattelli A, Dipalma G, Inchingolo AM, Inchingolo F, Di Pietro N, Trentadue B. The Influence of Cement Thickness within the Cap on Stress Distribution for Dental Implants. J Funct Biomater 2024; 15:199. [PMID: 39057320 PMCID: PMC11278485 DOI: 10.3390/jfb15070199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2024] [Revised: 07/12/2024] [Accepted: 07/18/2024] [Indexed: 07/28/2024] Open
Abstract
The purpose of this finite element analysis (FEA) was to evaluate the stress distribution within the prosthetic components and bone in relation to varying cement thicknesses (from 20 to 60 μm) utilized to attach a zirconia crown on a conometric cap. The study focused on two types of implants (Cyroth and TAC, AoN Implants, Grisignano di Zocco, Italy) featuring a Morse cone connection. Detailed three-dimensional (3D) models were developed to represent the bone structure (cortical and trabecular) and the prosthetic components, including the crown, cement, cap, abutment, and the implant. Both implants were placed 1.5 mm subcrestally and subjected to a 200 N load at a 45° inclination on the crown. The results indicated that an increase in cement thickness led to a reduction in von Mises stress on the cortical bone for both Cyroth and TAC implants, while the decrease in stress on the trabecular bone (apical zone) was relatively less pronounced. However, the TAC implant exhibited a higher stress field in the apical area compared to the Cyroth implant. In summary, this study investigated the influence of cement thickness on stress transmission across prosthetic components and peri-implant tissues through FEA analysis, emphasizing that the 60 μm cement layer demonstrated higher stress values approaching the material strength limit.
Collapse
Affiliation(s)
- Mario Ceddia
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy; (M.C.); (B.T.)
| | - Tea Romasco
- Department of Medical, Oral and Biotechnological Sciences, “G. D’Annunzio” University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy;
- Center for Advanced Studies and Technology (CAST), “G. D’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy
| | - Luca Comuzzi
- Independent Researcher, 31020 San Vendemiano, Italy;
| | | | - Adriano Piattelli
- School of Dentistry, Saint Camillus International University of Health and Medical Sciences, 00131 Rome, Italy;
- Facultad de Medicina, UCAM Universidad Católica San Antonio de Murcia, 30107 Murcia, Spain
| | - Gianna Dipalma
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (G.D.); (A.M.I.); (F.I.)
| | - Angelo Michele Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (G.D.); (A.M.I.); (F.I.)
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (G.D.); (A.M.I.); (F.I.)
| | - Natalia Di Pietro
- Department of Medical, Oral and Biotechnological Sciences, “G. D’Annunzio” University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy;
- Center for Advanced Studies and Technology (CAST), “G. D’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy
| | - Bartolomeo Trentadue
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy; (M.C.); (B.T.)
| |
Collapse
|
21
|
Pascoal ALDB, Paiva KRG, Marinho LCN, Bezerra ADS, Calderon PDS. Impact of splinting implant-supported crowns on the performance of adjacent posterior implants: A systematic review and meta-analysis. J Prosthet Dent 2024:S0022-3913(24)00373-1. [PMID: 38955598 DOI: 10.1016/j.prosdent.2024.05.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 05/24/2024] [Accepted: 05/29/2024] [Indexed: 07/04/2024]
Abstract
STATEMENT OF PROBLEM While rehabilitation with implant-supported crowns in the posterior region is widely practiced, guidance on clinical considerations when choosing between splinted or nonsplinted implant-supported crowns is limited. PURPOSE The purpose of this systematic review with meta-analysis was to assess whether adjacent implants with internal connections in the posterior region should be treated with splinted or nonsplinted crowns. MATERIAL AND METHODS The systematic review was registered on the prospective register of systematic reviews (PROSPERO) under the code, CRD42021248525. Two authors searched 4 electronic databases (PubMed, Cochrane Library, Scopus, and Web of Science) independently for articles published up to December 2023. Additionally, a hand search was conducted in the nonpeer-reviewed literature and the reference lists of included articles. Only clinical studies comparing splinted and nonsplinted hexagonal or conical internal connection adjacent implants in the posterior region were considered. A single-arm meta-analysis was conducted using RevMan. Risk of bias and quality were assessed using the Cochrane Collaboration's Tool for Assessing Risk and the Newcastle-Ottawa scale. RESULTS Qualitative synthesis included 17 studies, and quantitative synthesis involved 13 studies. A total of 2085 implants (1244 splinted and 841 nonsplinted) were inserted in 1027 participants, with observation times ranging from 5 months to 16 years. Thirteen studies related the type of crown retention (cemented or screw-retained). Only 2 studies related annual bone loss results considering the type of crown retention, but whether they were splinted or nonsplinted crowns and significant differences were not specified. The meta-analysis revealed no statistical differences between splinted and nonsplinted implants for biological complications (P=.95, I2=0%). However, the nonsplinted implants exhibited significantly more mechanical complications than the splinted implants (P<.001, I2=1%, RR 0.37; 95% IC [0.26-0.54]). The studies included demonstrated a low risk of bias and were of good quality. CONCLUSIONS Splinting was not found to affect the incidence of biological complications in posterior adjacent implants. However, more mechanical complications occurred in nonsplinted crowns than splinted ones.
Collapse
Affiliation(s)
- Ana Luísa de Barros Pascoal
- Temporary Assistant Professor, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil
| | | | | | - Aliane da Silva Bezerra
- Postgraduate student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil.
| | | |
Collapse
|
22
|
Agustín-Panadero R, Baixauli-López M, Fernández-Estevan L, Senent-Vicente G, Revilla-León M, Gómez-Polo M. Resistance to loosening of intentionally shortened screws used to solve the unsuccessful removal of fractured prosthetic screws. J Prosthet Dent 2024; 132:165-171. [PMID: 37596156 DOI: 10.1016/j.prosdent.2023.06.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 06/27/2023] [Accepted: 06/29/2023] [Indexed: 08/20/2023]
Abstract
STATEMENT OF PROBLEM Fractured prosthetic implant screws cannot be removed in all patients, ultimately leading to the removal of the implant. Whether an intentionally shortened prosthetic implant screw (SPIS) can provide adequate retention is unclear. PURPOSE The purpose of this in vitro study was to evaluate the resistance to loosening of SPISs engaging the remaining coronal internal threads as a possible solution to maintaining both implant and restoration. MATERIAL AND METHODS Fifty grade V titanium SPISs were used to tighten 50 titanium transepithelial abutments on implants to 30 Ncm. The specimens were distributed into 5 groups (n=10) according to the conditions under which the screws were secured to manufacturer-recommended preload: dry (D), moistened in saliva (AS), moistened in chlorhexidine (CLHX), wrapped in polytetrafluoroethylene tape (PTFE), and resin cemented (RE). All groups were subjected to a cyclic loading test (240 000 cycles). The reverse torque value (RTV) of the SPIS was registered twice: 24 hours after initial tightening (T1); and after retightening and the cyclic loading test (T2). The resultant RTV was compared with the 30-Ncm tightening torque to assess torque loosening. The Kruskal-Wallis and Mann-Whitney tests were used for the comparisons between groups and the Wilcoxon test for the intragroup comparisons (α=.05 with Bonferroni correction). RESULTS At T1, all groups found lower mean±standard deviation RTVs than the reference tightening torque (30 Ncm) (D 24.82±2.34 Ncm, AS 25.56±2.89 Ncm, PTFE 26.02±2.26 Ncm, CLHX 26.26±1.82 Ncm), except the resin-cemented group, which increased its RTV (RE 44.01±19.94 Ncm). At T2, all the groups found lower RTVs than the reference tightening torque, and the torque values at T1 (D 19.81±6.59 Ncm, CLHX 18.98±6.36 Ncm, AS 21.28±7.32 Ncm), with the exception of PTFE (24.07±3.41 Ncm) and RE (41.47±21.68 Ncm), where RTV was similar to that recorded at T1. At T1, significant differences were found among the groups (P=.024). At T2, after cyclic loading, the RE group found the highest RTV, reporting significant differences with the D and CHLX groups (P<.05) and statistically similar to the AS group (P=.068). CONCLUSIONS PTFE-wrapped screws found similar RTVs after the fatigue test than dry, moistened with saliva, and moistened with chlorhexidine screws. Resin-cemented shortened prosthetic implant screws were found to be the most resistant to loosening after cyclic loading.
Collapse
Affiliation(s)
- Rubén Agustín-Panadero
- Associate Professor, Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, Valencia, Spain
| | - Mar Baixauli-López
- Adjunct Professor, Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, Spain.
| | - Lucía Fernández-Estevan
- Associate Professor, Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, Valencia, Spain
| | - Gisela Senent-Vicente
- Adjunct Professor, Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, Spain
| | - Marta Revilla-León
- Affiliate Faculty, Graduate Prosthodontics University of Washington, Seattle, Wash; Affiliate Faculty, Research and Digital Dentistry, Kois Center, Seattle, Wash; Affiliate Faculty, Researcher, Revilla Research Center, Madrid, Spain
| | - Miguel Gómez-Polo
- Associate Professor, Department of Prosthetic Dentistry, Faculty of Dentistry, Complutense University of Madrid, Madrid, Spain; Director of Postgraduate Program, School of Dentistry, Complutense University of Madrid, Madrid, Spain
| |
Collapse
|
23
|
Ramadan RE, Bahgat MM, Abdelhamid AM, Khamis MM. Registration of maxillomandibular relationship through a fully digital workflow for complete-mouth rehabilitation with screw-retained fixed implant-supported prostheses: A clinical report. J Prosthet Dent 2024; 132:6-13. [PMID: 36609083 DOI: 10.1016/j.prosdent.2022.11.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 11/04/2022] [Accepted: 11/04/2022] [Indexed: 01/06/2023]
Abstract
Digital recording of the maxillomandibular relationship by using intraoral scanning in completely edentulous patients for computer-aided design and computer-aided manufacture implant-supported prostheses can be challenging. This clinical report describes the fabrication of complete arch, screw-retained implant-supported prostheses in a completely edentulous patient with a fully digital workflow.
Collapse
Affiliation(s)
- Rania E Ramadan
- Assistant Lecturer, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| | - Mariam M Bahgat
- Assistant Lecturer, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Ahmed M Abdelhamid
- Professor, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Mohamed Moataz Khamis
- Professor and Chairman, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
24
|
Tabrizi R, Mehrabi P, Shafiei S, Azimi A, Moslemi H. Does crown-to-implant ratio affect marginal bone loss around a single short implant at the posterior of the mandible? Natl J Maxillofac Surg 2024; 15:273-277. [PMID: 39234123 PMCID: PMC11371288 DOI: 10.4103/njms.njms_27_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 10/29/2023] [Accepted: 12/13/2023] [Indexed: 09/06/2024] Open
Abstract
Context Short implants are acceptable treatment options for atrophic ridges; however, they increase the crown-to-implant (C/I) ratio compared to regular length implants. The study aimed to assess the correlation between the C/I ratio and marginal bone loss (MBL) in single short implants at the posterior of the mandible. Aims The study aimed to assess the correlation between the C/I ratio and MBL in single short implants at the posterior of the mandible. Settings and Design Cross-sectional study. Materials and Methods This cross-sectional study assessed short implants with 6 mm lengths at the posterior of the mandible. The long-cone peri-apical digital radiographs were taken immediately after loading and 24 months later. Age, gender, implant diameter, gingival biotype, and implant brands were the study variables, and the C/I ratio was the predictive factor. The mean MBL at 2 years was considered the study outcome. Statistical Analysis Used The Pearson correlation test was applied to assess the correlation between MBL and C/I. Results Seventy implants (36 Straumann and 34 SGS implants) were studied. A significant difference was observed in the mean MBL between the two implant brands (P < 0.001). Besides, a correlation was found between MBL and the C/I ratio (P = 0.002). Conclusions It seems that the C/I ratio is associated with an MBL increase in single short implants at the posterior of the mandible.
Collapse
Affiliation(s)
- Reza Tabrizi
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Pegah Mehrabi
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Shervin Shafiei
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Amir Azimi
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hamidreza Moslemi
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
25
|
Riberti N, D’Amico E, Pierfelice TV, Furlani M, Giuliani A, Piattelli A, Iezzi G, Comuzzi L. Case Report of a Dental Implant with Conometric Abutment-Prosthetic Cap Connection: Advanced High-Resolution Imaging and Peri-Implant Connective Tissue Performance. Clin Pract 2024; 14:556-569. [PMID: 38666801 PMCID: PMC11049280 DOI: 10.3390/clinpract14020043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 03/19/2024] [Accepted: 03/25/2024] [Indexed: 04/28/2024] Open
Abstract
Background: In recent years, the use of conometric systems to connect dental implant abutments and prosthetic caps has been advocated because they seem to eliminate the side effects reported when using screw- and cement-connected prosthetic restorations. Objectives: The present case study is focused on conometric connection characterization and its performance in terms of the microarchitecture of peri-implant soft tissues by using a cross-linked approach based on optical microscopy and three-dimensional imaging. Methods: Two dental implants were characterized using micro-CT and another identical one was implanted into a patient; the latter was retrieved 45 days later due to changes in prosthetic needs. Afterward, the peri-implant soft tissues were investigated using synchrotron-based phase contrast imaging, histology, and polarized light microscopy. Results: Micro-CT analysis showed perfect adhesion between the abutment and prosthetic cap; histology and polarized light microscopy showed that connective tissue was richly present around the abutment retrieved from the patient. Moreover, the quantitative evaluation of connective tissues using synchrotron imaging, supported by artificial intelligence, revealed that this tissue was rich in mature collagen, with longitudinal and transverse collagen bundles intertwined. The number and connectivity of transverse bundles were consistently greater than those of the longitudinal bundles. Conclusion: It was found that the peri-implant soft tissue was already mature and well organized after only 45 days of implantation, supporting the hypothesis that conometric connections contribute to the significant stabilization of peri-implant soft tissues.
Collapse
Affiliation(s)
- Nicole Riberti
- Neuroscience, Imaging and Clinical Sciences Department, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Emira D’Amico
- Medical, Oral and Biotechnological Sciences Department, University of Chieti-Pescara, 66100 Chieti, Italy; (E.D.); (T.V.P.); (G.I.)
| | - Tania Vanessa Pierfelice
- Medical, Oral and Biotechnological Sciences Department, University of Chieti-Pescara, 66100 Chieti, Italy; (E.D.); (T.V.P.); (G.I.)
| | - Michele Furlani
- Odontostomatologic and Specialized Clinical Sciences Department, Polytechnic University of Marche, Via Brecce Bianche, 60131 Ancona, Italy;
| | - Alessandra Giuliani
- Odontostomatologic and Specialized Clinical Sciences Department, Polytechnic University of Marche, Via Brecce Bianche, 60131 Ancona, Italy;
| | - Adriano Piattelli
- School of Dentistry, Saint Camillus International University for Health Sciences (Unicamillus), 00131 Rome, Italy;
| | - Giovanna Iezzi
- Medical, Oral and Biotechnological Sciences Department, University of Chieti-Pescara, 66100 Chieti, Italy; (E.D.); (T.V.P.); (G.I.)
| | - Luca Comuzzi
- Independent Researcher, Via Raffaello 36/a, 31020 San Vendemiano (TV), Italy;
| |
Collapse
|
26
|
Tajti P, Solyom E, Váncsa S, Mátrai P, Hegyi P, Varga G, Hermann P, Borbély J, Sculean A, Mikulás K. Less marginal bone loss around bone-level implants restored with long abutments: A systematic review and meta-analysis. Periodontol 2000 2024; 94:627-638. [PMID: 37766634 DOI: 10.1111/prd.12534] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 09/12/2023] [Accepted: 09/15/2023] [Indexed: 09/29/2023]
Abstract
The aim of this study was to investigate the biological outcomes of bone-level implants restored with long vs. short abutments, with regard to the 'one abutment at one time' protocol. The systematic search was performed in five databases: MEDLINE (PubMed), EMBASE, Web of Science, Scopus, and CENTRAL for randomized controlled trials up to January 14, 2023. Data were collected for marginal bone loss, bleeding on probing, and probing pocket depth by two reviewers. As effect size measure, mean difference (MD), and risk ratio (RR) were used for continuous and categorical outcomes, R-statistics software was used for conducting statistical analyses. For quality and certainty assessment, Risk of Bias Tool 2, ROBINS-I, and GRADE approach were used. The search resulted in 4055 records without any duplicates. After title, abstract, and full-text analysis, eight articles were found eligible for inclusion. Bone-level and platform-switched implants presented less marginal bone loss after 6 months and 1 year as well, when long abutments were used (MD 0.63, 95% CI: [-0.16; 1.42]) and (MD 0.26, 95% CI: [-0.02; 0.53]). However, subgroup analysis revealed no difference in marginal bone loss when applying 'one abutment at one time' protocol (p = 0.973). Bleeding on probing and probing pocket depth presented similarly good results in both groups without almost any differences (RR 0.97, 95% CI: [0.76; 1.23]) and (MD -0.05, 95% CI: [-1.11; 1.01]). Longer abutments on bone-level implants seem to be a favorable choice for decreasing early marginal bone loss, irrespective of connection timing.
Collapse
Affiliation(s)
- Péter Tajti
- Department of Prosthodontics, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Eleonora Solyom
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Department of Periodontology, Semmelweis University, Budapest, Hungary
| | - Szilárd Váncsa
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Péter Mátrai
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Péter Hegyi
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
- Institute of Pancreatic Diseases, Semmelweis University, Budapest, Hungary
| | - Gábor Varga
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Department of Oral Biology, Semmelweis University, Budapest, Hungary
| | - Péter Hermann
- Department of Prosthodontics, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Judit Borbély
- Department of Prosthodontics, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Anton Sculean
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Krisztina Mikulás
- Department of Prosthodontics, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| |
Collapse
|
27
|
Al-Juboori MJ, Al-Attas MA, Minichetti J, Akhikar J. The Use of Splinted Versus Nonsplinted Prosthetic Design in Dental Implants: A Literature Review. J ORAL IMPLANTOL 2024; 50:50-64. [PMID: 38329841 DOI: 10.1563/aaid-joi-d-23-00077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2024]
Abstract
The choice of a splinted or nonsplinted implant-supported prosthesis should be based on solid scientific evidence that considers the conditions and needs of each patient. This review elaborates on the factors that directly influence clinical decisions between splinted or nonsplinted dental implants. Digital and manual searches of the published literature were conducted to identify studies that examined splinted prostheses (SPs) and nonsplinted prostheses (NSPs). The search terms used, alone or in combination, were "splinting prosthesis," "nonsplinting prosthesis," "prosthetic design," "stress distribution in dental implant," "implant loading," "implant occlusion," and "crestal bone resorption." Ninety-four studies were selected to compare and address the details emphasized in this study. Thirty-four reported articles were not directly related to restoration design but were reviewed to better understand the influence of mechanical risk factors, finite element analysis limits, and criteria for implant survival and treatment success. There are advantages and disadvantages of splinting implants together. NSPs are the ideal choice because they resemble natural teeth. Splinting a restored implant will cause the implant to appear as part of one unit and is indicated in more compromised situations, unfavorable conditions, or when pontic spaces and cantilevers are needed in implant prostheses.
Collapse
Affiliation(s)
| | | | - John Minichetti
- Department of Dentistry, Englewood Hospital, Englewood, NJ, USA
| | | |
Collapse
|
28
|
Zhang M, Ho DKL, Pelekos G, Fok MR. Clinical performance of implant-supported single hybrid abutment crown restoration: A systematic review and meta-analysis. J Prosthodont Res 2024; 68:63-77. [PMID: 37316260 DOI: 10.2186/jpr.jpr_d_22_00279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
PURPOSE To investigate survival rates and technical and biological complications of one-piece screw-retained hybrid abutments in implant-supported single crowns (SCs). STUDY SELECTION An electronic search was performed on five databases for clinical studies involving implant-supported single hybrid abutment crowns constructed using titanium-base (Ti base) abutments, with at least 12 months of follow-up. The RoB 2, Robins-I, and JBI tools were used to assess the risk of bias for the different study types. Success, survival, and complication rates were calculated, and a meta-analysis was performed to obtain a pooled estimate. Peri-implant health parameters were extracted and analyzed. RESULTS 22 records (20 studies) were included in this analysis. Direct comparisons between screw-retained hybrid abutment SCs and cemented SCs showed no significant differences in the 1-year survival and success rates. For SCs using a hybrid abutment crown design, their 1-year survival rate was 100% (95% CI: 100%-100%, I2 = 0.0%, P = 0.984), and a success rate of 99% (95% CI: 97%-100%, I2 = 50.3%, P = 0.023) was calculated. No confounding variables significantly affected the estimates. The individual technical complication rate was low at 1-year follow-up. The estimated incidence of all types of complications in hybrid abutment SCs is less than 1%. CONCLUSIONS Within the limitations of this study, implant-supported SCs using a hybrid abutment crown design showed favorable short-term clinical outcomes. Additional well-designed clinical trials with at least a 5-year observation period are required to confirm their long-term clinical performance.
Collapse
Affiliation(s)
- Mengze Zhang
- Division of Periodontology and Implant Dentistry, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Dominic King Lun Ho
- Division of Periodontology and Implant Dentistry, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - George Pelekos
- Division of Periodontology and Implant Dentistry, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Melissa Rachel Fok
- Division of Periodontology and Implant Dentistry, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
29
|
Alevizakos V, Bergmann AL, von See C. Removal of broken abutment screws using ultrasonic tip - a heat development in-vitro study. BMC Oral Health 2024; 24:2. [PMID: 38166993 PMCID: PMC10762975 DOI: 10.1186/s12903-023-03654-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 11/10/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND Dental implants can cause complications, including the loosening of the abutment screw or fracture. However, there is no standardized technique for removing broken abutment screws. This necessitates further research. OBJECTIVE This study aimed to measure heat generation during screw removal to better understand its implications for dental implant procedures. MATERIAL AND METHODS The experimental setup involved using synthetic bone blocks and titanium implants. An ultrasonically operated instrument tip was utilized for screw removal. Infrared thermometry was employed for accurate temperature measurement, considering factors such as emissivity and distance. Statistical analysis using linear regression and ANOVA was conducted. RESULTS The findings revealed an initial rapid temperature increase during the removal process, followed by a gradual decrease. The regression model demonstrated a strong correlation between time and temperature, indicating the heat generation pattern. CONCLUSION Heat generation during screw removal poses risks such as tissue damage and integration issues. Clinicians should minimize heat risks through an intermittent approach. The lack of a standardized technique requires further research and caution. Understanding the generated heat optimizes implant procedures.
Collapse
Affiliation(s)
- Vasilios Alevizakos
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Danube Private University, Steiner Landstraße 124, Krems, an der Donau, 3500, Austria.
| | - Anna-Lena Bergmann
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Danube Private University, Steiner Landstraße 124, Krems, an der Donau, 3500, Austria
| | - Constantin von See
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Danube Private University, Steiner Landstraße 124, Krems, an der Donau, 3500, Austria
| |
Collapse
|
30
|
Schubert O, Goob J, Schweiger J, Güth JF, Edelhoff D, Graf T. Clinical performance of monolithic lithium disilicate hybrid abutment crowns over at least 3.5 years. J Prosthodont 2024; 33:34-40. [PMID: 37243453 DOI: 10.1111/jopr.13719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 05/19/2023] [Indexed: 05/28/2023] Open
Abstract
PURPOSE Hybrid abutment crowns (HACs) made from monolithic ceramics represent an efficient option for single restorations on implants. However, long-term data are scarce. The purpose of this clinical trial was to evaluate the survival and complication rates of CAD-CAM fabricated HACs over a time period of at least 3.5 years. MATERIALS AND METHODS Twenty-five patients with a total of 40 HACs made of monolithic lithium disilicate ceramic bonded to a titanium base CAD-CAM abutment were retrospectively evaluated. All implants and screw-retained restorations were placed and manufactured in the same department of a university hospital. Only crowns that had been in service for more than 3.5 years were included in the study. HACs were evaluated regarding technical and biological complications. Functional Implant Prosthodontic Scores (FIPS) were obtained. RESULTS The mean observation time was 5.9 ± 1.4 years. Implant survival was 100%, and HAC survival was 97.5%. Over the observation period, one crown fracture was observed, necessitating refabricating of the restoration. Three minor biological complications were found. The overall mean FIPS score was 8.69 ± 1.12 points. CONCLUSIONS Within the limitations of this study, monolithic screw-retained HACs milled from lithium disilicate ceramics and bonded to titanium bases appeared to be a reliable treatment option over more than 3.5 years due to their low biological and technical complication rates.
Collapse
Affiliation(s)
- Oliver Schubert
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Janosch Goob
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Josef Schweiger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Jan-Frederik Güth
- Department of Prosthodontics, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
| | - Daniel Edelhoff
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Tobias Graf
- Department of Prosthodontics, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
| |
Collapse
|
31
|
Han JW, Han JW, Pyo SW, Kim S. Impact of profile angle of CAD-CAM abutment on the marginal bone loss of implant-supported single-tooth posterior restorations. J Prosthet Dent 2023:S0022-3913(23)00780-1. [PMID: 38129258 DOI: 10.1016/j.prosdent.2023.11.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/19/2023] [Accepted: 11/20/2023] [Indexed: 12/23/2023]
Abstract
STATEMENT OF PROBLEM Although the emergence angle has been related to marginal bone loss, information regarding the relationship between the transmucosal configuration of a computer-aided design and computer-aided manufacturing (CAD-CAM) abutment at specific subgingival levels and the amount of marginal bone loss is lacking. PURPOSE The purpose of this retrospective clinical study was to evaluate the influence of CAD-CAM abutment profile angles, measured at different subgingival positions, on the marginal bone loss of posterior single-tooth implant-supported restorations. MATERIAL AND METHODS A total of 260 posterior single-tooth implant-supported restorations using CAD-CAM abutments were analyzed in 206 patients. All implants had internal conical seal connections with a platform-switched design. The following data were extracted using digital periapical radiography: emergence profile, profile angle at distance ranges of 0 to 1 mm, 1 to 2 mm, and 2 to 3 mm from the implant-abutment junction, and peri-implant marginal bone loss (MBL). The MBL was measured from the time of delivery of the restorations up to 7 years or more. A linear mixed model was applied to investigate whether there was a significant difference in MBL based on the emergence profile and time, followed by the Bonferroni correction post hoc test. A Pearson correlation analysis was used to analyze the correlation between the profile angle and MBL at each distance range. The cut-off points for each distance range were determined by using the c-index, and independent t tests were conducted based on these cut-off values to evaluate the statistical differences (α=.05 for all statistical analyses). RESULTS The convex emergence profile exhibited greater MBL than the concave and straight profiles at each follow-up visit (P<.001). A significant correlation was found between the profile angle and MBL in the 0 to 1 mm, 1 to 2 mm distance ranges. However, no significant correlation was found between the profile angle and MBL in the 2 to 3 mm distance range (P>.05). The cut-off points were 34 degrees at the mesial and 28 degrees at the distal in the 0 to 1 mm range, and 33 and 20 degrees at the mesial and distal in the 1 to 2 mm range. CONCLUSIONS The profile angle near the implant-abutment junction and the type of emergence profile of the CAD-CAM abutment were closely associated with MBL in implants with internal conical seal connection with a platform switch design.
Collapse
Affiliation(s)
- Jin-Won Han
- Former Graduate student, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Jin-Woo Han
- Graduate student, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Se-Wook Pyo
- Clinical Assistant Professor, Department of Prosthodontics, Gangnam Severance Dental Hospital, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Sunjai Kim
- Professor and Chairman, Department of Prosthodontics, Gangnam Severance Dental Hospital, Yonsei University College of Dentistry, Seoul, Republic of Korea.
| |
Collapse
|
32
|
Jongsiri S, Arksornnukit M, Homsiang W, Kamonkhantikul K. Effect of Restoration Design on the Removal Torque Loss of Implant-supported Crowns after Cyclic Loading. J Contemp Dent Pract 2023; 24:951-956. [PMID: 38317392 DOI: 10.5005/jp-journals-10024-3604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2024]
Abstract
AIM To compare the removal torque loss (RTL) percentage of screw-retained, cement-retained, and combined screw- and cement-retained implant-supported crowns after cyclic loading and measure the impact of cyclic loading on removal torque. MATERIALS AND METHODS Thirty-two dental implants (4.0 × 10 mm) in resin blocks and abutments were divided into four groups (n = 8) based on restoration design: combined screw- and cement-retained group (SC), two cement-retained groups: cemented with adhesive resin cement (AR) (Panavia V5) or provisional cement (PR) (RelyX Temp NE), and screw-retained one-piece titanium group (TI). Removal torques were measured in Newton-centimeter (Ncm) before and after 500,000-cycle cyclic loading with forces ranging from 20 to 200 N at 15 Hz. The RTL percentage in each group was calculated. The paired t-test was used to detect the difference between pre-loading (RT1) and post-loading removal torque (RT2) in each group and 1-way ANOVA was used to detect the difference of RTL percentage between groups. RESULTS The post-loading removal torques in all groups were significantly lower than their pre-loading removal torques (p < 0.001). The 1-way ANOVA test found no significant difference in the RTL% between the study groups. The PR group exhibited the lower RTL% (30.74 ± 7.3%), followed by the TI (30.78 ± 5.6%), AR (32.12 ± 2.5%), and SC (35.71 ± 5.1%) groups. CONCLUSION Combined screw- and cement-retained restorations exhibited similar RTL compared with other restoration designs, and cyclic loading significantly affected the removal torque. CLINICAL SIGNIFICANCE Combined screw- and cement-retained restorations can be utilized in single-tooth situations, offering a comparable impact on screw joint stability while providing benefit of retrievability. Cyclic loading significantly influences joint stability, periodic checkup for screw loosening is recommended. How to cite this article: Jongsiri S, Arksornnukit M, Homsiang W, et al. Effect of Restoration Design on the Removal Torque Loss of Implant-supported Crowns after Cyclic Loading. J Contemp Dent Pract 2023;24(12):951-956.
Collapse
Affiliation(s)
- Suppanut Jongsiri
- Esthetic Restorative and Implant Dentistry Program, Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Pathumwan, Bangkok, Thailand, Orcid: https://orcid.org/0009-0005-8918-601X
| | - Mansuang Arksornnukit
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Pathumwan, Bangkok, Thailand, Orcid: https://orcid.org/0000-0001-5356-4086
| | - Woraporn Homsiang
- Department of Family and Community Dentistry, Faculty of Dentistry, Chiang Mai University, Suthep, Chiang Mai, Thailand, Orcid: https://orcid.org/0000-0003-2908-292X
| | - Krid Kamonkhantikul
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Pathumwan, Bangkok, Thailand, Phone: +66945599524, e-mail: , Orcid: https://orcid.org/0000-0002-0660-162X
| |
Collapse
|
33
|
da Silva Bezerra A, Ribeiro AKC, Veríssimo AH, de Almeida EO. Prosthetic complications and failures of implant-supported fixed partial dentures: A scoping review. J Prosthet Dent 2023:S0022-3913(23)00707-2. [PMID: 38036319 DOI: 10.1016/j.prosdent.2023.10.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Revised: 10/16/2023] [Accepted: 10/17/2023] [Indexed: 12/02/2023]
Abstract
STATEMENT OF PROBLEM Although high survival rates of implant-supported fixed partial dentures (ISFPDs) have been reported, evidence for complications, failures, and factors that interfere with their longevity is lacking. PURPOSE The purpose of this scoping review was to review the literature to investigate the most common failures and complications of ISFPDs. MATERIAL AND METHODS This review followed the preferred reporting items for systematic reviews and meta-analyses scoping review (PRISMA ScR) guidelines, and the methodology was registered on the open science framework (osf.io/5xqkp). An electronic search was conducted in PubMed/MEDLINE, Embase, Cochrane Library, Scopus, and Web of Science databases and nonpeer-reviewed literature for articles published from 2013 to January 2023. Studies that evaluated the clinical performance of ISFPDs with at least 1 year of follow-up and described the concepts of failure and success were included. RESULTS The search yielded 5695 studies. Fourteen articles were included in this review for data extraction. Veneering porcelain fracture, screw fracture, and implant loss were the most common failures reported. Technical complications mainly involved screw loosening, loss of retention, and wear of the screw-access restoration. CONCLUSIONS Bruxism, mismatch of the thermal expansion coefficient, unsatisfactory support of the framework, choice of cement, shape of the titanium abutments, and extended length of the cantilever were associated with the longevity of the ISFPD. Despite the high survival rate of ISFPDs, data must be carefully interpreted because of the variation in the materials used to manufacture the ISFPD and the heterogeneity of the studies in this review.
Collapse
Affiliation(s)
- Aliane da Silva Bezerra
- Researcher, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil.
| | - Anne Kaline Claudino Ribeiro
- Postgraduate student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil
| | | | - Erika Oliveira de Almeida
- Adjunct Professor, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil
| |
Collapse
|
34
|
Giglio GD, Giglio AB. Achieving optimal implant esthetics using a team approach Part 1 a review of evidence-based criteria in implant treatment. J Prosthet Dent 2023; 130:661-662. [PMID: 37739881 DOI: 10.1016/j.prosdent.2023.08.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 08/25/2023] [Accepted: 08/25/2023] [Indexed: 09/24/2023]
Abstract
As dental implants have evolved into a universally accepted treatment option, it is essential to identify nuances of the peri-implant complex and their impact on treatment given the increasing evidence of peri-implantitis and implant loss. A thorough knowledge of anatomy and biology, careful treatment planning, correct placement, prosthetic and occlusal design, and proper long-term maintenance all play a role in dental implant therapy. The goal of this part 1 presentation is to review evidence-based criteria in implant treatment including the surgical and restorative parameters, and the desired implant features, with the objective of achieving predictable results that improve the longevity of the implant and restoration, maintain peri-implant health, and optimize the esthetic outcome. By following science-based guidelines, implant treatment can be improved and simplified with more predictable results, especially in the esthetic zone, where demands are greater and there is less room for error.
Collapse
Affiliation(s)
- Graziano D Giglio
- Adjunct Clinical Associate Professor, Advanced Education Program in Prosthodontics, New York University College of Dentistry, New York, NY.
| | - Ana Becil Giglio
- Adjunct Clinical Associate Professor, Advanced Education Program in Periodontics and Implant Dentistry, New York University College of Dentistry, New York, NY
| |
Collapse
|
35
|
Reis INRD, Fukuoka GL, Nagay BE, Pannuti CM, Spin-Neto R, da Silva EVF. Incidence of peri-implant disease associated with cement- and screw-retained implant-supported prostheses: A systematic review and meta-analysis. J Prosthet Dent 2023:S0022-3913(23)00563-2. [PMID: 37793953 DOI: 10.1016/j.prosdent.2023.08.030] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 08/23/2023] [Accepted: 08/24/2023] [Indexed: 10/06/2023]
Abstract
STATEMENT OF PROBLEM Implant-supported fixed dental prostheses can be cement- or screw-retained on the implant or abutment, with advantages and disadvantages for each method. Cemented prostheses have been associated with peri-implant disease because cement remnants act as a reservoir for bacteria and hinder biofilm control. However, contrasting evidence has been presented regarding this association based on studies with varying designs, and a systematic review and meta-analysis is required. PURPOSE The purpose of this systematic review and meta-analysis was to answer the focused question: In patients who received implant-supported prostheses, is the incidence of peri-implant diseases higher in cemented implant-supported prostheses than in screw-retained ones? MATERIAL AND METHODS The search was conducted using the National Library of Medicine (MEDLINE-PubMed), SCOPUS, EMBASE, and ISI Web of Science databases. Randomized clinical trials (RCTs) that assessed the incidence of peri-implant disease in cement- and screw-retained prostheses were included. Two authors independently screened the titles and abstracts, and analyzed the full texts, extracted data, and assessed the risk of bias. The findings were summarized using meta-analyses with random effects, and the level of certainty of the evidence was determined using the grading of recommendations, assessments, development, and evaluations (GRADE) approach. RESULTS The search yielded 4455 articles that met the inclusion criteria based on the title and/or abstract selection. A total of 6 RCTs were included for analysis. The meta-analysis revealed no significant difference between cement- and screw-retained prostheses for the risk of peri-implant mucositis (RR: 1.36, 95% CI: 0.42-4.38, P=.61). Similarly, no significant difference was observed between cement- and screw-retained prostheses for the incidence of peri-implantitis (RR: 1.00, 95% CI: 0.23-4.31, P=1.00). CONCLUSIONS Moderate certainty evidence suggests that cement- and screw-retained prostheses present a similar risk for peri-implant mucositis and peri-implantitis.
Collapse
Affiliation(s)
- Isabella Neme Ribeiro Dos Reis
- Postgraduate student, Department of Stomatology, Division of Periodontics, School of Dentistry, University of São Paulo (USP), São Paulo, Brazil.
| | - Gisele Lie Fukuoka
- Postgraduate student, Department of Prosthodontics, School of Dentistry, University of São Paulo (USP), São Paulo, Brazil
| | - Bruna Egumi Nagay
- Postgraduate student, Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Brazil
| | - Claudio Mendes Pannuti
- Associate Professor, Department of Stomatology, Division of Periodontics, School of Dentistry, University of São Paulo (USP), São Paulo, Brazil
| | - Rubens Spin-Neto
- Associate Professor, Department of Dentistry and Oral Health, Section for Oral Radiology, School of Dentistry, Aarhus University, Aarhus, Denmark
| | | |
Collapse
|
36
|
Cascos R, Celemín-Viñuela A, Mory-Rubiños N, Gómez-Polo C, Ortega R, Agustín-Panadero R, Gómez-Polo M. Influence of the Use of Transepithelial Abutments vs. Titanium Base Abutments on Microgap Formation at the Dental Implant-Abutment Interface: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6532. [PMID: 37834669 PMCID: PMC10573618 DOI: 10.3390/ma16196532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 09/22/2023] [Accepted: 09/28/2023] [Indexed: 10/15/2023]
Abstract
This in vitro study aimed to assess the presence of microgaps at the implant-abutment interface in monolithic zirconia partial implant-supported fixed prostheses on transepithelial abutments versus Ti-base abutments. METHODS Sixty conical connection dental implants were divided into two groups (n = 30). The control group consisted of three-unit bridge monolithic zirconia connected to two implants by a transepithelial abutment. The test group consisted of monolithic zirconia three-unit restoration connected to two implants directly by a titanium base (Ti-base) abutment. The sample was subjected to thermocycling (10,000 cycles at 5 °C to 55 °C, dwelling time 50 s) and chewing simulation (300,000 cycles, under 200 N at frequencies of 2 Hz, at a 30° angle). The microgap was evaluated at six points (mesiobuccal, buccal, distobuccal, mesiolingual, lingual, and distolingual) of each implant-abutment interface by using a scanning electron microscope (SEM). The data were analyzed using the Mann-Whitney U tests (p > 0.05). RESULTS The SEM analysis showed a smaller microgap at the implant-abutment interface in the control group (0.270 μm) than in the test group (3.902 μm). Statistically significant differences were observed between both groups (p < 0.05). CONCLUSIONS The use or not of transepithelial abutments affects the microgap size. The transepithelial abutments group presented lower microgap values at the interface with the implant than the Ti-base group in monolithic zirconia partial implant-supported fixed prostheses. However, both groups had microgap values within the clinically acceptable range.
Collapse
Affiliation(s)
- Rocío Cascos
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (A.C.-V.); (N.M.-R.); (M.G.-P.)
- Department of Nursing and Estomatology, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain
- Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, 28670 Madrid, Spain;
| | - Alicia Celemín-Viñuela
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (A.C.-V.); (N.M.-R.); (M.G.-P.)
| | - Nataly Mory-Rubiños
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (A.C.-V.); (N.M.-R.); (M.G.-P.)
| | - Cristina Gómez-Polo
- Department of Surgery, Faculty of Medicine, University of Salamanca, 37007 Salamanca, Spain;
| | - Rocío Ortega
- Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, 28670 Madrid, Spain;
| | - Rubén Agustín-Panadero
- Prosthodontic and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, 46010 Valencia, Spain;
| | - Miguel Gómez-Polo
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (A.C.-V.); (N.M.-R.); (M.G.-P.)
| |
Collapse
|
37
|
Grande F, Cesare PM, Mochi Zamperoli E, Gianoli CM, Mollica F, Catapano S. Evaluation of Tension and Deformation in a Mandibular Toronto Bridge Anchored on Three Fixtures Using Different Framework Materials, Abutment Systems, and Loading Conditions: A FEM Analysis. Eur J Dent 2023; 17:1097-1105. [PMID: 36696917 PMCID: PMC10756777 DOI: 10.1055/s-0042-1758785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
OBJECTIVE The aim of this study was to investigate by finite element method analysis the behaviour of a three-implant mandible Toronto framework made by three different materials, with two abutment systems and two loading conditions. MATERIALS AND METHODS Three implants were virtually inserted in a mandible model in positions 3.6, 4.1, and 4.6. Three prosthetic framework bars with the same design and dimension (4.8 × 5.5 mm) were projected. The variables introduced in the computer model were the framework materials (glass fiber reinforced resin, Co-Cr, TiAl6V4), the abutment systems (Multi-Unit-Abutment [MUA]/OT-Bridge), and the loading conditions (500 N vertical load on all the framework area and 400 N on a 7-mm distal cantilever). The computer was programmed with physical properties of the materials as derived from the literature. Maximum tension and deformation values for each variable were registered at framework, screws, and abutment level and then compared. RESULTS Metal frameworks Cr-Co and TiAl6V4 resulted in lower deformation than glass fiber-reinforced resin frameworks while presenting higher tension values. The OT-Bridge exhibited lower maximum tension and deformation values than the MUA system. The first loading condition reached higher tension and deformation values than the second and it resulted in more uniformly distributed load on all the framework area, especially with the OT-Bridge system. CONCLUSION More rigid materials and OT-Bridge system decrease the deformation on the prosthetic components. Tension stresses are more uniformly distributed with glass fiber-reinforced resin, in the OT-Bridge system and avoiding cantilever loading.
Collapse
Affiliation(s)
- Francesco Grande
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | | | | | | | | | - Santo Catapano
- Department of Prosthodontics, University of Ferrara, Ferrara, Italy
| |
Collapse
|
38
|
Chen J, Guo J, Yang L, Wang L, Zhang X. Effect of different implant angulations on the biomechanical performance of prosthetic screws in two implant-supported, screw-retained prostheses: A numerical and experimental study. J Prosthet Dent 2023; 130:240.e1-240.e10. [PMID: 37419710 DOI: 10.1016/j.prosdent.2023.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 06/05/2023] [Accepted: 06/07/2023] [Indexed: 07/09/2023]
Abstract
STATEMENT OF PROBLEM: A mesiodistal angle frequently forms between 2 splinted implant-supported, screw-retained fixed dental prostheses (TIS-FDPs). Mechanical complications commonly occur in prosthetic screws. Studies regarding the effect of the degree of implant angulation on the biomechanical performance of prosthetic screws in TIS-FDPs are sparse. PURPOSE The purpose of this numerical and experimental study was to investigate the effects of different implant angulations on the biomechanical performance, including stress distribution, stability of the screw joint, and surface morphology change of the prosthetic screws in TIS-FDPs. MATERIAL AND METHODS TIS-FDPs were classified into 4 groups: 0, 10, 20, and 30 degrees based on the degree of mesiodistal angle between the long axes of the 2 implants. In the finite element analysis (FEA), 4 series of 3D models were constructed and loaded with simulated occlusal forces. The von Mises stresses and rotational angles of the prosthetic screws were then calculated. In the mechanical test, each group of 5 TIS-FDPs with 10 prosthetic screws was tested under 1 million loading cycles by using a universal testing machine. The removal torque values (RTVs) and the surface roughness of the prosthetic screws were measured after cyclic loading. The normality of the outcome variables was assessed by the Shapiro-Wilk test. Analysis of variance and the Kruskal-Wallis test were used for further analysis (α=.05). RESULTS The FEA results showed that the von Mises stresses of the prosthetic screws were concentrated in the first screw thread crest engaged with the abutment, and the maximum values of the threads and the rotation angles of the prosthetic screws increased in the 2-implant mesiodistal angulation from 0 to 30 degrees. The mechanical tests showed that the RTVs of the prosthetic screws in each group were not significantly different after 1 million loading cycles (P=.107). The surface roughness of the crest of the first 2 threads of the prosthetic screws in the 30-degree group changed significantly compared with those in the other groups. CONCLUSIONS When TIS-FDPs were delivered, larger angulations of the 2 splinted implants seemed to increase the stress concentrated on the crest of the first engaged thread and the rotation angles of the prosthetic screws. After 1 million loading cycles, significant surface adhesive wear was identified on the crest of the first 2 threads of the prosthetic screws in the 30-degree group compared with groups with a smaller angulation.
Collapse
Affiliation(s)
- Jianyu Chen
- Assistant Professor, Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, PR China
| | - Jiaer Guo
- Graduate student, Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, PR China
| | - Lijia Yang
- Graduate student, College of Stomatology, Jinan University, Guangzhou, PR China
| | - Lin Wang
- Associate Professor, Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, PR China.
| | - Xiao Zhang
- Engineer, Foshan Angels Biotechnology Co. Ltd, Foshan, PR China
| |
Collapse
|
39
|
de Oliveira Mota VP, Braga MS, Loss AA, Mello HN, Rosetti EP, de-Azevedo-Vaz SL. Detection of misfits at the abutment-prosthesis interface in the esthetic zone: Implications of the radiographic technique and the magnitude of the misfit. J Prosthet Dent 2023; 130:239.e1-239.e9. [PMID: 37455164 DOI: 10.1016/j.prosdent.2023.05.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 05/23/2023] [Accepted: 05/24/2023] [Indexed: 07/18/2023]
Abstract
STATEMENT OF PROBLEM Misfits in the abutment-prosthesis interface represent a setback for implant-supported prostheses. Periapical radiographs have been used as an auxiliary method in the evaluation of prosthesis fit to the abutments; however, the evidence supporting the use of this method is still restricted to studies of low to moderate quality. Furthermore, studies on the diagnostic accuracy of different periapical techniques used to detect misfits in the abutment-prosthesis interface, especially in the esthetic zone, are lacking. PURPOSE The purpose of this in vitro study was to assess the discrimination power of 3 periapical radiographic techniques in detecting misfits at the abutment-prosthesis interface in the esthetic zone and evaluate whether the magnitude of the misfit influenced the diagnosis. MATERIAL AND METHODS A total of 15 implants with an internal conical connection were installed in the central incisor region in polyamide jaws. Custom ceramic copings for cemented crowns were made by using a computer-aided design and computer-aided manufacturing (CAD-CAM) system. Misfits of 50, 100, and 150 µm were simulated by interposing 1, 2, or 3 50-μm-thick polyester strips at the abutment-prosthesis interface; the absence of the strip represented the control group. Digital radiographs were obtained by using film holders for the following periapical techniques: bisecting angle (PBA), standard paralleling (PSP), and modified paralleling (PMP). Two radiologists and 1 prosthodontist evaluated a total of 180 radiographs. The values of the area under the receiver operating characteristic curve (Az) were regarded as a measure of diagnostic accuracy and subjected to the Friedman test with post hoc Durbin-Conover (α=.05). RESULTS The PSP (Az=0.873) had higher Az values than the PBA (Az=0.753) for the 50-μm misfits (P<.05). Larger misfits resulted in greater accuracy than smaller misfits (P<.05). Interactions between the factors radiographic technique and misfit magnitude resulted in statistically significant differences for all comparisons (P<.05), except between the PSP for the 100-μm misfits (Az=0.976) and the PMP for the 150-μm misfits (Az=0.998). CONCLUSIONS The PSP was more accurate than the PBA in detecting the 50-µm misfits at the abutment-prosthesis interface; larger misfits resulted in more accurate diagnoses, regardless of the technique used.
Collapse
Affiliation(s)
- Vanessa Pacheco de Oliveira Mota
- Graduate student, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Manuella Soussa Braga
- Undergraduate student, Department of Clinical Dentistry, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Amanda Alves Loss
- Undergraduate student, Department of Clinical Dentistry, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Hugo Nogueira Mello
- Graduate student, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Elizabeth Pimentel Rosetti
- Professor, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Sergio Lins de-Azevedo-Vaz
- Professor, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil.
| |
Collapse
|
40
|
Ghaly M, Tarrazzi D, Xia V, Tharrington S, Schoenbaum TR. Changes in Peri-implant Marginal Bone Level by Jaw Location: A Systematic Review and Meta-Analysis of 4970 Implants. J ORAL IMPLANTOL 2023; 49:444-455. [PMID: 37527152 DOI: 10.1563/aaid-joi-d-22-00252] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 05/03/2023] [Accepted: 05/29/2023] [Indexed: 08/03/2023]
Abstract
The purpose of this study was to evaluate the current evidence on marginal bone-level changes (ΔMBL) around internal connection implants with fixed prostheses by jaw location over time. An electronic literature search for ΔMBL (change in marginal bone level) was conducted in 6 databases. The data from the included manuscripts were categorized by jaw sextant of the implants and duration of follow-up (<2 years, 2-5 years, and >5 years). Meta-analyses were performed on groups with at least 5 studies. A total of 1270 records were screened. Full-text review of 413 papers resulted in a total of 46 studies (representing 2259 patients with 4970 implants) included for quantitative synthesis and analysis. The ΔMBL was summarized at 2 time intervals with the following results: <2 years (anterior maxilla = 0.393 mm [95% confidence interval {CI}, 0.172, 0.613], posterior maxilla = 0.468 mm [95% CI, 0.288, 0.648], and posterior mandible 0.559 mm [95% CI, 0.397, 0.72]), 2 to 5 years (anterior maxilla = 0.683 mm [95% CI, 0.224, 1.142], posterior maxilla = 0.645 mm [95% CI, 0.42, 0.87], and posterior mandible 0.563 mm [95% CI, 0.278, 0.849]). There were insufficient studies in the anterior mandible and with follow-up data over 5 years for quantitative synthesis. Within the limitations of this study, location within the maxillary and mandibular jaws does not seem to influence ΔMBL around internal connection bone level implants with fixed restorations. Although there may be a tendency for greater initial remodeling in the posterior mandible followed by long-term stability, additional studies are needed to evaluate this further.
Collapse
Affiliation(s)
- Mira Ghaly
- Department of Periodontics, Dental College of Georgia, Augusta University, Augusta GA, USA
| | - Daler Tarrazzi
- Department of Restorative Sciences, Dental College of Georgia, Augusta University, Augusta GA, USA
| | - Veronica Xia
- Dental College of Georgia, Augusta University, Augusta GA, USA
| | | | - Todd R Schoenbaum
- Department of Restorative Sciences, Dental College of Georgia, Augusta University, Augusta GA, USA
| |
Collapse
|
41
|
Brennand Roper M, Vissink A, Dudding T, Pollard A, Gareb B, Malevez C, Balshi T, Brecht L, Kumar V, Wu Y, Jung R. Long-term treatment outcomes with zygomatic implants: a systematic review and meta-analysis. Int J Implant Dent 2023; 9:21. [PMID: 37405545 DOI: 10.1186/s40729-023-00479-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 05/09/2023] [Indexed: 07/06/2023] Open
Abstract
PURPOSE The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses survival and success, sinus pathology and patient reported outcomes were also investigated. METHODS Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines were followed. Embase and OvidMedline databases were searched alongside the grey literature. The systematic review was recorded in PROSPERO (CRD42022358024). Studies reporting titanium/titanium alloy ZI survival data, ZI-supported prosthesis data, ZIs directly compared to any other implant therapy including grafted sites, a minimum follow-up time of 3 years and a minimum number of 10 patients were included. All study designs were considered if they met the inclusion criteria. Studies not involving ZIs, ZIs not made from titanium/titanium alloy, a follow-up time of < 3 years or < 10 patients, animal studies and in vitro studies were excluded. Long-term follow-up has not been defined in the literature. A minimum of 3 years follow-up was considered acceptable to capture survival after initial healing, alongside in-function prosthesis data via delayed or immediate load protocols. ZI success, was predominantly defined as ZI survival without biological or neurological complications. Meta-analyses were performed for ZI survival, ZI failure incidence, ZI success, loading protocol, prosthesis survival, and prevalence of sinusitis using random effects models. Descriptive analysis was used for ZI success, prosthesis success and patient reported outcome measures. RESULTS Five hundred and seventy-four titles were identified, of which 18 met the inclusion criteria. Eligible studies included 1349 ZIs in 623 patients. Mean follow-up period was 75.4 months (range 36-141.6). The mean survival of ZIs was 96.2% [95% CI: 93.8; 97.7] at 6 years. Mean survival for delayed loading was 95% [95% CI: 91.7; 97.1] and 98.1% [95% CI: 96.2; 99.0] for immediate loading (p = 0.03). Annual incidence rate of ZI failure was 0.7% [95% CI 0.4; 1.0]. Mean ZI success was 95.7% [95% CI 87.8; 98.6]. Mean prosthesis survival was 94% [95% CI 88.6; 96.9]. Sinusitis prevalence was 14.2% [95% CI 8.8; 22.0] at 5 years. Patients' reported increased satisfaction with ZIs. CONCLUSIONS ZIs have long-term survival comparable to conventional implants. Immediate loading showed a statistically significant increase in survival over delayed loading. Prosthesis survival was similar to that of prostheses supported by conventional implants, with similar complications. Sinusitis was the most frequently encountered biological complication. Patients reported improved outcome measures with ZI use.
Collapse
Affiliation(s)
- Matthew Brennand Roper
- Department of Restorative Dentistry, University Hospitals Bristol and Weston Foundation Trust, Bristol Dental Hospital, Lower Maudlin Street, Bristol, BS1 2LY, UK.
| | - Arjan Vissink
- Department of Oral and Maxillofacial Surgery, Universtitair Medisch Centrum Gronigen, Groningen, The Netherlands
| | - Tom Dudding
- Department of Restorative Dentistry, University Hospitals Bristol and Weston Foundation Trust, Bristol Dental Hospital, Lower Maudlin Street, Bristol, BS1 2LY, UK
| | - Alex Pollard
- Department of Restorative Dentistry, University Hospitals Bristol and Weston Foundation Trust, Bristol Dental Hospital, Lower Maudlin Street, Bristol, BS1 2LY, UK
| | - Barzi Gareb
- Department of Oral and Maxillofacial Surgery, Universtitair Medisch Centrum Gronigen, Groningen, The Netherlands
| | - Chantal Malevez
- Department of Oral and Maxillofacial Surgery, Clinique Saint-Jean, Brussels, Belgium
| | | | - Lawrence Brecht
- Division of Prosthodontics and Restorative Dentistry, NYC College of Dentistry, New York City, NY, USA
| | - Vinay Kumar
- Department of Oral and Maxillofacial Surgery, Uppsala University, Uppsala, Sweden
| | - Yiqun Wu
- Department of Oral Implantology, Second Dental Center, Ninth People's Hospital Affiliated with Shanghai Jaio Tong University, School of Medicine, Shanghai, China
| | - Ronald Jung
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
42
|
Roccuzzo A, Imber JC, Salvi GE, Roccuzzo M. Peri-implantitis as the consequence of errors in implant therapy. Periodontol 2000 2023; 92:350-361. [PMID: 36744582 DOI: 10.1111/prd.12482] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 09/04/2022] [Accepted: 12/22/2022] [Indexed: 02/07/2023]
Abstract
Peri-implantitis is a plaque-associated pathologic condition occurring in tissues around dental implants, characterized by inflammation in the peri-implant mucosa and subsequent progressive loss of supporting bone. It is a highly prevalent disease, as extensively estimated by large-population, cross-sectional studies. As peri-implant diseases represent opportunistic infections, it is reasonable to assume that nonideal conditions, local and/or general, may favor the progression of peri-implant inflammation. Some of these conditions could be a result of poor planning and/or inadequate execution of any step of the entire process treatment. This article describes the major possible factors in implant therapy that may lead to peri-implantitis. For some of these (ie, inappropriate patient selection, insufficient periodontal therapy, lack of diagnosis and management of peri-implant mucositis, erratic supportive peri-implant/periodontal therapy) there is a good level of evidence, whereas for others (ie, wrong implant placement, poor postoperative care, inadequate prosthetic reconstruction, lack of assessment and management of peri-implant soft-tissue deficiencies) there is little scientific evidence. More research is therefore needed to clearly identify the errors and/or complications possibly leading to peri-implantitis, particularly over the long term.
Collapse
Affiliation(s)
- Andrea Roccuzzo
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Oral and Maxillo-Facial Surgery, Copenhagen University Hospital (Rigshospitalet), Copenhagen, Denmark
| | - Jean-Claude Imber
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Giovanni Edoardo Salvi
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mario Roccuzzo
- Specialist Periodontal Private Practice, Torino, Italy
- Division of Maxillo-facial Surgery, University of Torino, Torino, Italy
- Department of Periodontics and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
43
|
Ye Z, Ye H, Jiang Z, Wu S, Feng Z, Liu H, Wang X, Lan R, Lin X, Ding C, Zhang Q, Ding X, Wu L. Influence of Different Implant Designs on Replacement of Four Teeth of The Posterior Free-end Edentulism: Three-dimensional Finite Element Analysis and Clinic Case Validation. Ann Anat 2023:152111. [PMID: 37247761 DOI: 10.1016/j.aanat.2023.152111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 03/15/2023] [Accepted: 05/15/2023] [Indexed: 05/31/2023]
Abstract
BACKGROUND With periodontal disease having an increasing incidence, mandibular free-end edentulism caused by periodontitis is clinically more common. Finite element analysis and clinical case reports were used to evaluate the influence of different designs on the load distribution of implant prosthesis in mandibular posterior free-end edentulism. METHOD A finite element model of a mandible with posterior free-end edentulism was established. Considering the implant position and selection of single crown repair or splint repair, four designs were conducted including model A: 3435×37(four-unit fixed bridge supported by three implants, implant positions were 34, 35, 37); model B: 34,35×37, (34: a single implant crown) (35×37: three-unit fixed bridge supported by two implants, implant positions were 35, 37); model C: 34×3637(four-unit fixed bridge supported by three implants, implant positions were 34, 36, 37); and model D: 34×36, 37(37: a single implant crown)(34×36: three-unit fixed bridge supported by two implants, implant positions were 34, 36). Stress distribution and the Von Mises stress value of the implants, the crown and the bone around the implants were analyzed at vertical and 45° inclined load. RESULTS Stress in the cortical bone was mainly concentrated around the implant neck, and maximum Von Mises stress (MVMS) of the four models was 11.6-16.1MPa at vertical load and 61.74-96.49MPa at 45° inclined load. Stress in the cancellous bone was concentrated around the implant base, and MVMS of four models was 3.075-3.899MPa at vertical load and 5.021-6.165MPa at 45° inclined load. Stress of the restoration crowns was mainly concentrated in the connector of the bridge, and MVMS of four models was 23.38-26.28MPa at vertical load and 53.14-56.35MPa at 45° inclined load. Stress of the implant interface was mainly concentrated on the surface of the smaller implants near the bridge, and MVMS of four models was 21.12-33.25MPa at vertical load and 83.73-138.7MPa at 45° inclined load. CONCLUSION There was favorable stress distribution of the four models at vertical load and 45° inclined load. Design of a three-unit fixed bridge combined with a partial crown may be an available option for devising patient treatment plans with mandibular free-end edentulism.
Collapse
Affiliation(s)
- Zhangyan Ye
- Department of Stomatology, Pingyang Hospital Affiliated of Wenzhou Medical University(The People's Hospital of Pingyang), Wenzhou, 325400 Zhejiang; P.R. China; Institute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China.
| | - Hao Ye
- Institute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China.
| | - Zhengting Jiang
- Department of Stomatology, The first affiliated hospital of Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China
| | - Suwen Wu
- Department of Stomatology, Pingyang Hospital Affiliated of Wenzhou Medical University(The People's Hospital of Pingyang), Wenzhou, 325400 Zhejiang; P.R. China
| | - Zhongqiang Feng
- Department of Stomatology, Pingyang Hospital Affiliated of Wenzhou Medical University(The People's Hospital of Pingyang), Wenzhou, 325400 Zhejiang; P.R. China
| | - Hongwen Liu
- Institute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China
| | - Xinyi Wang
- Institute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China
| | - Ruotian Lan
- Institute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China
| | - Xinyi Lin
- Institute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China
| | - Chenlu Ding
- Institute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China
| | - Qi Zhang
- Institute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China
| | - Xi Ding
- Department of Stomatology, The first affiliated hospital of Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China.
| | - Lijun Wu
- Institute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325015 Zhejiang; P.R. China.
| |
Collapse
|
44
|
Naeini EN, Atashkadeh M, Jacquet W, D'Haese J, De Bruyn H. Incidence of Peri-Implantitis, Technical and Biological Complications of Single Implants Placed with Flap or Flapless Surgery-A 10-12-Year Case-Series. J Clin Med 2023; 12:jcm12113668. [PMID: 37297870 DOI: 10.3390/jcm12113668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Revised: 04/13/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023] Open
Abstract
BACKGROUND Long-term follow-up of single implants and crowns is scarce, especially when inserted using flapless surgery. AIM Evaluate survival, peri-implantitis incidence, and technical/biologic complications of solitary implants/crowns after 10-12 years of function. MATERIAL AND METHODS 49 patients with 53 single implants, initially operated with a one-stage flap (F) or flapless (FL) surgery and delayed loading, were recalled. Implant survival, radiographic bone-level changes compared to baseline, peri-implant health, and soft tissue aesthetics were registered. Differences in implant level between and within groups were statistically tested using the Mann-Whitney U-Test and Wilcoxon Signed Ranks Test, respectively. RESULTS 36 patients with 40 implants were reassessed, yielding 100% implant and 97.5% crown survival. The bone loss in F (n = 19) was 0.56 mm (SD 0.89; range -0.9-2.02) and -0.85 mm (SD 0.98; range -2.84-0.53) in FL (n = 21), indicative of bone gain in FL (p = 0.003), the latter due to a difference at baseline but bone-level was comparable (p = 0.126). Groups were comparable for probing pocket depth (PPD); (3.32 vs. 3.19 mm), Bleeding Index (BI); (0.15 vs. 0.22), and gingival recession; (0.38 vs. 0.17 mm). According to international criteria, the peri-implantitis incidence was 0%, but 32.5% of the implants/crowns experienced biological or technical complications irrespective of surgical technique. CONCLUSIONS Solitary implants and crowns show good long-term clinical outcomes and peri-implant health. Flapless surgery is a good alternative to conventional in straightforward cases with sufficient bone volume and proper treatment planning.
Collapse
Affiliation(s)
- Emitis Natali Naeini
- Department of Periodontology and Implantology, Department of Dentistry, Radboud University Medical Centre, 6525 GA Nijmegen, The Netherlands
| | | | - Wolfgang Jacquet
- Department of Surgical Clinical Sciences CHIR-ORHE, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, 1050 Brussels, Belgium
- Department of Educational Sciences EDWE-LOCI, Faculty of Psychology and Educational Sciences, Vrije Universiteit Brussel, 1050 Brussels, Belgium
| | - Jan D'Haese
- Department of Periodontology and Implantology, Department of Dentistry, Radboud University Medical Centre, 6525 GA Nijmegen, The Netherlands
| | - Hugo De Bruyn
- Department of Periodontology and Implantology, Department of Dentistry, Radboud University Medical Centre, 6525 GA Nijmegen, The Netherlands
- Department of Periodontology and Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, 9000 Gent, Belgium
| |
Collapse
|
45
|
Choi JH, Heo SJ, Koak JY, Kim SK, Park JM, Ahn JS. Effect of hemispherical dimples at titanium implant abutments for the retention of cemented crowns. J Adv Prosthodont 2023; 15:63-71. [PMID: 37153008 PMCID: PMC10154144 DOI: 10.4047/jap.2023.15.2.63] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 12/06/2022] [Accepted: 01/31/2023] [Indexed: 05/09/2023] Open
Abstract
PURPOSE The aim of this study was to assess the effect of hemispherical dimple structures on the retention of cobalt-chromium (Co-Cr) crowns cemented to titanium abutments, with different heights and numbers of dimples on the axial walls. MATERIALS AND METHODS 3.0-mm and 6.0-mm abutments (N = 180) and Co-Cr crowns were prepared. The experimental groups were divided into two and four dimple groups. The crowns were cemented by TempBond and PANAVIA F 2.0 cements. The retention forces were measured after thermal treatments. A two-way Analysis of Variance (ANOVA) and post-hoc Tukey HSD test were conducted to analyze change in retention forces by use of dimples between groups, as well as t test for the effect of abutment height change (α = .05). RESULTS Results of the two-way ANOVA showed a statistically significant difference in retention force due to the use of dimples, regardless of the types of cements used (P < .001). A significantly higher mean retention forces were observed in the groups with dimples than in the control group, using the post hoc Tukey HSD test (P < .001). Results of t test displayed a statistically significant increase in the retention force with 6.0-mm abutments compared with 3.0-mm abutments (P < .001). The groups without dimples revealed adhesive failure of cements, while the groups with dimples showed mixed failure of cements. CONCLUSION Use of hemispherical dimples was effective for increasing retention forces of cemented crowns.
Collapse
Affiliation(s)
- Jung-Hoon Choi
- Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Seong-Joo Heo
- Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Jai-Young Koak
- Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Seong-Kyun Kim
- Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Ji-Man Park
- Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Jin-Soo Ahn
- Department of Dental Biomaterials Science and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| |
Collapse
|
46
|
Heller H, Beitlitum I, Goldberger T, Emodi-Perlman A, Levartovsky S. Outcomes and Complications of 33 Soft-Milled Cobalt-Chromium-Ceramic Full-Arch Screw-Retained Implant-Supported Prostheses: A Retrospective Study with up to 10-Year Follow-up. J Funct Biomater 2023; 14:jfb14030157. [PMID: 36976081 PMCID: PMC10053464 DOI: 10.3390/jfb14030157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 03/10/2023] [Accepted: 03/13/2023] [Indexed: 03/18/2023] Open
Abstract
This retrospective study assessed outcomes and complications related to implants and prostheses in edentulous patients treated with soft-milled cobalt-chromium-ceramic full-arch screw-retained implant-supported prostheses (SCCSIPs). After the final prosthesis was delivered, patients participated in an annual dental check-up program, including clinical and radiographic assessments. Outcomes of implants and prostheses were evaluated, and biological and technical complications were categorized as major or minor. Implant and prosthesis cumulative survival rates were assessed using the life table analysis. A total of twenty-five participants (mean age 63.6 ± 7.3 years) with 33 SCCSIPs were observed for a mean of 68.9 ± 27.9 months (range 1–10 years). A total of 7 out of 245 implants were lost, with no effect on prosthesis survival, leading to cumulative survival rates of 97.1% for implants and 100% for prostheses. The most recurrent minor and major biological complications were soft tissue recession (9%) and late implant failure (2.8%). Among 25 technical complications, porcelain fracture was the only major technical complication, requiring prosthesis removal (1%). Porcelain chipping was the most frequent minor technical complication, affecting 21 crowns (5.4%), which required polishing only. At the end of the follow-up, 69.7% of the prostheses were free of technical complications. Within the limitations of this study, SCCSIP showed promising clinical performance after 1–10 years.
Collapse
Affiliation(s)
- Hadas Heller
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Ilan Beitlitum
- Department of Periodontology and Dental Implantology, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Tomer Goldberger
- Department of Endodontics, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Alona Emodi-Perlman
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Shifra Levartovsky
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- Correspondence: ; Tel.: +972-52-3515403
| |
Collapse
|
47
|
Korello K, Eickholz P, Zuhr O, Ratka C, Petsos H. In vitro efficacy of non-surgical and surgical implant surface decontamination methods in three different defect configurations in the presence or absence of a suprastructure. Clin Implant Dent Relat Res 2023. [PMID: 36918345 DOI: 10.1111/cid.13198] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 01/30/2023] [Accepted: 02/22/2023] [Indexed: 03/15/2023]
Abstract
OBJECTIVES Analysis of the in vitro efficacy of non-surgical and surgical dental implant surface decontamination with or without suprastructure. MATERIALS AND METHODS Three hundred and sixty implants were dipped in indelible red and distributed to 30°, 60°, or 90° angulated bone defect models. One hundred and twenty implants were used for each bone defect, 40 of which were assigned to a decontamination method (CUR: curette; SOSC: soundscaler; APA: air powder abrasion). Of these, 20 were subjected to a simulated non-surgical (NST) or surgical treatment (ST), with/without mucosa mask, of which 10 were carried out with (S+) or without (S-) suprastructure. Uncleaned implant surface was assessed by both-sided implant surface photography. Surface morphology changes were analyzed using scanning electron microscopy (SEM). RESULTS Cleaning efficacy was significantly better within NST if the suprastructure was removed (p < 0.001). No significant difference was found within ST (p = 0.304). Overall, cleaning efficacy in the order APA > SOSC>CUR decreased significantly (p < 0.0001) for both S+ and S- in NST as well as ST. Separated by NST/ST, S+/S-, defect angulation and decontamination method, only isolated significant differences in cleaning efficacy were present. Linear regression analysis revealed significant associations of remnants with the treatment approach, decontamination method, and defect angle (p < 0.0001). SEM micrographs showed serious surface damage after use of CUR and SOSC. CONCLUSIONS Suprastructure removal is an additional option to improve cleaning efficacy of non-surgical implant surface decontamination in this in vitro model.
Collapse
Affiliation(s)
- Katharina Korello
- Department of Periodontology, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt, Frankfurt, Germany.,Private Practice, Frankfurt, Germany
| | - Peter Eickholz
- Department of Periodontology, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt, Frankfurt, Germany
| | - Otto Zuhr
- Department of Periodontology, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt, Frankfurt, Germany.,Private Practice, Munich, Germany
| | | | - Hari Petsos
- Department of Periodontology, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt, Frankfurt, Germany.,Private Practice, Butzbach, Germany
| |
Collapse
|
48
|
Naumann M, Scholz P, Krois J, Schwendicke F, Sterzenbach G, Happe A. Monolithic hybrid abutment crowns (screw-retained) versus monolithic hybrid abutments with adhesively cemented monolithic crowns. Clin Oral Implants Res 2023; 34:209-220. [PMID: 36692161 DOI: 10.1111/clr.14031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 12/30/2022] [Accepted: 01/02/2023] [Indexed: 01/25/2023]
Abstract
OBJECTIVES The objective of this study is to compare monolithic hybrid abutment crowns (screw-retained) versus monolithic hybrid abutments with adhesively cemented monolithic single-tooth crowns. MATERIALS AND METHODS Twenty subjects in need of an implant-borne restoration were randomly assigned to receive either a cement-retained (CRR) or a screw-retained (SRR) implant-supported monolithic lithium disilicate (LS2 ) reconstruction. Each patient received a titanium implant with in internal conic connection. After osseointegration and second-stage surgery, healing abutments were placed for about 10 days. The type of restoration (CRR vs. SRR) was randomly assigned, and the restorations were manufactured of monolithic LS2 . Both types of restorations, CRR and SRR, were based on a titanium component (Ti-base) that was bonded to the abutment (CRR) or the crown (SRR). The follow-up period for all restoration was 36 months. Clinical outcome was evaluated according to Functional Implant Prosthetic Score (FIPS). Quality of live (OHIP) and patient's satisfaction were assessed using patient-reported outcome measures (PROMs). Primary endpoint was loss of restoration for any reason. Kaplan-Meier curves were constructed and log-rank testing was performed (p < .05). RESULTS One restoration of group CRR failed after 6 months due to loss of adhesion between Ti-base and individual abutment. No further biological or technical failures occurred. Kaplan-Meier analysis showed no significant difference between both treatment options (p = .317). There was no statistically significant difference between both types of restoration, neither for FIPS, OHIP, treatment time nor patient satisfaction (p > .05). CONCLUSION Monolithic hybrid abutment crowns (screw-retained) and monolithic hybrid abutment with adhesively cemented monolithic crowns using lithium disilicate showed no statistically significant difference for implant-based reconstructions in this pilot RCT setting.
Collapse
Affiliation(s)
- Michael Naumann
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders-Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| | - Patricia Scholz
- Clinic for Dental Prosthetics, Center for Dental, Oral and Maxillofacial Medicine, University Hospital Ulm, Ulm, Germany
| | - Joachim Krois
- Department of Oral Diagnostics, Digital Health and Health Services Research, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Falk Schwendicke
- Department of Oral Diagnostics, Digital Health and Health Services Research, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Guido Sterzenbach
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders-Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| | - Arndt Happe
- Clinic for Dental Prosthetics, Center for Dental, Oral and Maxillofacial Medicine, University Hospital Ulm, Ulm, Germany
| |
Collapse
|
49
|
Reverse Torque Value of Angulated Screw Channel Abutment before and after Cyclic Loading: An In Vitro Study. J Funct Biomater 2023; 14:jfb14030124. [PMID: 36976048 PMCID: PMC10051685 DOI: 10.3390/jfb14030124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/20/2023] [Accepted: 02/22/2023] [Indexed: 03/03/2023] Open
Abstract
This in vitro experiment aimed to understand the difference in preload acting on an abutment screw under different angles of angulated screw-retained crown and the performance after cyclic loading. In total, thirty implants with angulated screw channel (ASC) abutments were divided into two parts. The first part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5), a 15° access channel with a specially designed zirconia crown (sASC-15) (n = 5), and a 25° access channel with a specially designed zirconia crown (sASC-25) (n = 5). The reverse torque value (RTV) was measured at 0° for each specimen. The second part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5); a 15° access channel with a zirconia crown (ASC-15) (n = 5), and a 25° access channel with a zirconia crown (ASC-25) (n = 5). The manufacturer’s recommended torque was applied to each specimen, and baseline RTV was measured before cyclic loading. Each ASC implant assembly was cyclically loaded at 0 to 40 N with 1 million cycles at 10 Hz. RTV was measured after cyclic loading. Kruskal–Wallis test and Jonckheere–Terpstra test were used for statistical analysis. All specimens were examined under a digital microscope and scanning electron microscope (SEM) to observe the wear of the screw head before and after the whole experiment. A significant difference in the different percentages of straight RTV (sRTV) between the three groups was found (p = 0.027). The angle of ASC to the different percentages of sRTV showed a significant linear trend (p = 0.003). No significant differences were found in RTV difference after cyclic loading among the ASC-0, ASC-15, and ASC-25 groups (p = 0.212). The ASC-25 group had the most serious degree of wear based on a digital microscope and SEM examination. The ASC angle will affect the actual preload acting on a screw: the larger the ASC angle, the smaller the preload. The performance of the angled ASC groups in RTV difference was comparable to that of 0° ASC after cyclic loading.
Collapse
|
50
|
Spinelli A, Zamparini F, Romanos G, Gandolfi MG, Prati C. Tissue-Level Laser-Lok Implants Placed with a Flapless Technique: A 4-Year Clinical Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1293. [PMID: 36770298 PMCID: PMC9919502 DOI: 10.3390/ma16031293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 12/29/2022] [Accepted: 01/27/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND The present study aims to analyze the use of Laser-Lok microtextured neck implants placed with a transmucosal surgical approach. The marginal bone level (MBL) and periodontal parameters were evaluated in a cohort prospective 4-year clinical study. METHODS A total of 41 implants were placed in 36 healthy consecutive patients (16 males, 20 females, mean age 60 ± 9 years). Tapered tissue level implants, characterized by a 2.0 mm laser-microtextured neck, were used with a flapless approach. Customized abutments and provisional resin crowns were positioned. Definitive metal-ceramic crowns were cemented approximately 4 months after insertion. Periapical radiographs were taken after 1, 3, 6, 12, 36 and 48 months from implant placement to evaluate MBL. Gingival thickness (thin/thick), plaque score (PS) and bleeding on probing (BoP) were evaluated. RESULTS After 48 months, all implants were safe from complications. No complications, peri-implantitis, early implant failures or mucositis occurred. The survival rate was 100%. Mean MBL during the follow-up was -0.15 ± 0.18 at T1, -0.29 ± 0.29 at T3, -0.45 ± 0.37 at T6, -0.53 ± 0.45 at T12, -1.06 ± 1.13 at T 36 and -1.10 ± 0.89 at T 48. Implants placed 2-3 months after tooth extraction revealed lower MBL variation when compared to those placed immediately (in fresh extraction sockets) or in completely healed ridges (delayed group). Narrower diameter implants (3.8 mm) showed significantly higher MBL variation when compared to 4.6 diameter implants. Multilevel analysis at T48 revealed that among all the evaluated variables, implant diameter was the factor mostly associated with MBL modifications (p = 0.027). CONCLUSION This 4-year clinical study supports the use of Laser-Lok implants placed at tissue level with a flapless approach. A limited bone loss during the 48-month follow-up was observed. Periodontal parameters were stable with no sign of inflammation or soft tissue alteration. The use of Laser-Lok implants with transmucosal surgery represents a suitable technique with a minimally invasive approach.
Collapse
Affiliation(s)
- Andrea Spinelli
- Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40125 Bologna, Italy
| | - Fausto Zamparini
- Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40125 Bologna, Italy
- Laboratory of Biomaterials and Oral Pathology, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40125 Bologna, Italy
| | - Georgios Romanos
- Department of Periodontics and Endodontics, School of Dental Medicine, Stony Brook, NY 11794, USA
| | - Maria Giovanna Gandolfi
- Laboratory of Biomaterials and Oral Pathology, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40125 Bologna, Italy
| | - Carlo Prati
- Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40125 Bologna, Italy
| |
Collapse
|