1
|
Stepanovska J, Matejka R, Rosina J, Bacakova L, Kolarova H. Treatments for enhancing the biocompatibility of titanium implants. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2020; 164:23-33. [PMID: 31907491 DOI: 10.5507/bp.2019.062] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Accepted: 12/17/2019] [Indexed: 12/31/2022] Open
Abstract
Titanium surface treatment is a crucial process for achieving sufficient osseointegration of an implant into the bone. If the implant does not heal sufficiently, serious complications may occur, e.g. infection, inflammation, aseptic loosening of the implant, or the stress-shielding effect, as a result of which the implant may need to be reoperated. After a titanium graft has been implanted, several interactions are crucial in order to create a strong bone-implant connection. It is essential that cells adhere to the surface of the implant. Surface roughness has a significant influence on cell adhesion, and also on improving and accelerating osseointegration. Other highly important factors are biocompatibility and resistance to bacterial contamination. Bio-inertness of titanium is ensured by the protective film of titanium oxides that forms spontaneously on its surface. This film prevents the penetration of metal compounds, and it is well-adhesive for calcium and phosphate ions, which are necessary for the formation of the mineralized bone structure. Since the presence of the film alone is not sufficient for the biocompatibility of titanium, a suitable surface finish is required to create a firm bone-implant connection. In this review, we explain and compare the most widely-used methods for modulating the surface roughness of titanium implants in order to enhance cell adhesion on the surface of the implant, e.g. plasma spraying, sandblasting, acid etching, laser treatment, sol-gel etc., The methods are divided into three overlapping groups, according to the type of modification.
Collapse
Affiliation(s)
- Jana Stepanovska
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.,Department of Biomaterials and Tissue Engineering, Institute of Physiology, Czech Academy of Sciences, Prague, Czech Republic
| | - Roman Matejka
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.,Department of Biomaterials and Tissue Engineering, Institute of Physiology, Czech Academy of Sciences, Prague, Czech Republic
| | - Jozef Rosina
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic
| | - Lucie Bacakova
- Department of Biomaterials and Tissue Engineering, Institute of Physiology, Czech Academy of Sciences, Prague, Czech Republic
| | - Hana Kolarova
- Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic
| |
Collapse
|
2
|
Asensio G, Vázquez-Lasa B, Rojo L. Achievements in the Topographic Design of Commercial Titanium Dental Implants: Towards Anti-Peri-Implantitis Surfaces. J Clin Med 2019; 8:E1982. [PMID: 31739615 PMCID: PMC6912779 DOI: 10.3390/jcm8111982] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 11/04/2019] [Accepted: 11/11/2019] [Indexed: 12/12/2022] Open
Abstract
Titanium and its alloys constitute the gold standard materials for oral implantology in which their performance is mainly conditioned by their osseointegration capacity in the host's bone. We aim to provide an overview of the advances in surface modification of commercial dental implants analyzing and comparing the osseointegration capacity and the clinical outcome exhibited by different surfaces. Besides, the development of peri-implantitis constitutes one of the most common causes of implant loss due to bacteria colonization. Thus, a synergic response from industry and materials scientists is needed to provide reliable technical and commercial solutions to this issue. The second part of the review focuses on an update of the recent findings toward the development of new materials with osteogenic and antibacterial capacity that are most likely to be marketed, and their correlation with implant geometry, biomechanical behavior, biomaterials features, and clinical outcomes.
Collapse
Affiliation(s)
- Gerardo Asensio
- Instituto de Ciencia y Tecnología de Polímeros, Consejo Superior de Investigaciones Científicas, CSIC, 28006 Madrid, Spain; (G.A.); (B.V.-L.)
| | - Blanca Vázquez-Lasa
- Instituto de Ciencia y Tecnología de Polímeros, Consejo Superior de Investigaciones Científicas, CSIC, 28006 Madrid, Spain; (G.A.); (B.V.-L.)
- Consorcio Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina, CIBER-BBN, 28029 Madrid, Spain
| | - Luis Rojo
- Instituto de Ciencia y Tecnología de Polímeros, Consejo Superior de Investigaciones Científicas, CSIC, 28006 Madrid, Spain; (G.A.); (B.V.-L.)
- Consorcio Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina, CIBER-BBN, 28029 Madrid, Spain
| |
Collapse
|
3
|
Mangano F, Raspanti M, Maghaireh H, Mangano C. Scanning Electron Microscope (SEM) Evaluation of the Interface between a Nanostructured Calcium-Incorporated Dental Implant Surface and the Human Bone. MATERIALS 2017; 10:ma10121438. [PMID: 29258208 PMCID: PMC5744373 DOI: 10.3390/ma10121438] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Revised: 12/13/2017] [Accepted: 12/14/2017] [Indexed: 12/26/2022]
Abstract
Purpose. The aim of this scanning electron microscope (SEM) study was to investigate the interface between the bone and a novel nanostructured calcium-incorporated dental implant surface in humans. Methods. A dental implant (Anyridge®, Megagen Implant Co., Gyeongbuk, South Korea) with a nanostructured calcium-incorporated surface (Xpeed®, Megagen Implant Co., Gyeongbuk, South Korea), which had been placed a month earlier in a fully healed site of the posterior maxilla (#14) of a 48-year-old female patient, and which had been subjected to immediate functional loading, was removed after a traumatic injury. Despite the violent trauma that caused mobilization of the fixture, its surface appeared to be covered by a firmly attached, intact tissue; therefore, it was subjected to SEM examination. The implant surface of an unused nanostructured calcium-incorporated implant was also observed under SEM, as control. Results. The surface of the unused implant showed a highly-structured texture, carved by irregular, multi-scale hollows reminiscent of a fractal structure. It appeared perfectly clean and devoid of any contamination. The human specimen showed trabecular bone firmly anchored to the implant surface, bridging the screw threads and filling the spaces among them. Conclusions. Within the limits of this human histological report, the sample analyzed showed that the nanostructured calcium-incorporated surface was covered by new bone, one month after placement in the posterior maxilla, under an immediate functional loading protocol.
Collapse
Affiliation(s)
- Francesco Mangano
- Department of Medicine and Surgery, University of Insubria, Varese 21100, Italy.
| | - Mario Raspanti
- Department of Medicine and Surgery, University of Insubria, Varese 21100, Italy.
| | | | - Carlo Mangano
- Department of Dental Sciences, University Vita Salute S. Raffaele, Milan 20132, Italy.
| |
Collapse
|
4
|
Mangano FG, Iezzi G, Shibli JA, Pires JT, Luongo G, Piattelli A, Mangano C. Early bone formation around immediately loaded implants with nanostructured calcium-incorporated and machined surface: a randomized, controlled histologic and histomorphometric study in the human posterior maxilla. Clin Oral Investig 2017; 21:2603-2611. [PMID: 28154996 DOI: 10.1007/s00784-017-2061-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Accepted: 01/25/2017] [Indexed: 01/01/2023]
Abstract
OBJECTIVE The aim of this randomized, controlled histologic/histomorphometric study was to compare the early bone formation around immediately loaded implants with nanostructured calcium-incorporated (NCI) and machined (MA) surface, placed in the human posterior maxilla. MATERIALS AND METHODS Fifteen fully edentulous patients (six males; nine females; mean age 57.9 ± 6.7 years) were selected for this study. Each patient was installed with two temporary transmucosal implants, with different surfaces: one NCI (test) and one MA (control) implant. All temporary implants were placed in the posterior maxilla, according to a split-mouth design, to help to support an interim complete maxillary denture. After 8 weeks, all temporary transmucosal implants were retrieved for histologic/histomorphometric evaluation. The bone-to-implant contact (BIC%) and the bone density (BD%) were calculated. The Wilcoxon matched-pairs signed-rank test was used to evaluate differences (BIC%, BD%) between the surfaces. The level of significance was set at 0.05. RESULTS Eight weeks after placement, 24 clinically stable implants (12 test, 12 control) were subjected to histologic/histomorphometric evaluation. In the MA implants, the histomorphometric evaluation revealed a mean BIC(±SD)% and BD(±SD)% of 21.2(±4.9)% and 29.8(±7.8)%, respectively. In the NCI implants, the histomorphometric analysis revealed a mean BIC(±SD)% and BD(±SD)% of 39.7(±8.7)% and 34.6(±7.2)%, respectively. A statistically significant difference was found between the two surfaces with regard to BIC% (p < 0.001), while no significant difference was found with regard to BD% (p = 0.09). CONCLUSIONS The NCI surface seems to increase the peri-implant endosseous healing properties in the native bone of the posterior maxilla, under immediate loading conditions, when compared with the MA surface. CLINICAL RELEVANCE Under immediate loading conditions in the human posterior maxilla, the nanostructured calcium-incorporated surface has led to better histologic and histomorphometric results than the machined surface; therefore, the clinical use of implants with nanostructured calcium-incorporated surface may be beneficial in the posterior maxilla, under immediate loading protocol.
Collapse
Affiliation(s)
- Francesco Guido Mangano
- Department of Surgical and Morphological Science, Dental School, University of Varese, 21100, Varese, Italy. .,, Piazza Trento 4, 22015, Gravedona, Como, Italy.
| | - Giovanna Iezzi
- Department of Medical, Oral, and Biotechnological Sciences, University of Chieti-Pescara, Chieti, Italy
| | - Jamil Awad Shibli
- Department of Periodontology, Oral Implantology Clinic, Dental Research Division, Guarulhos University, Sao Paulo, Brazil
| | - Jefferson Trabach Pires
- Department of Periodontology, Oral Implantology Clinic, Dental Research Division, Guarulhos University, Sao Paulo, Brazil
| | - Giuseppe Luongo
- Department of Oral and Maxillofacial Surgery, University of Naples, Naples, Italy
| | - Adriano Piattelli
- Department of Medical, Oral, and Biotechnological Sciences, University of Chieti-Pescara, Chieti, Italy
| | - Carlo Mangano
- Department of Dental Sciences, University Vita Salute S. Raffaele, Milan, Italy
| |
Collapse
|
5
|
In vivo biofunctionalization of titanium patient-specific implants with nano hydroxyapatite and other nano calcium phosphate coatings: A systematic review. J Craniomaxillofac Surg 2016; 44:400-12. [DOI: 10.1016/j.jcms.2015.12.004] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2015] [Revised: 11/05/2015] [Accepted: 12/11/2015] [Indexed: 12/22/2022] Open
|
6
|
Besinis A, De Peralta T, Tredwin CJ, Handy RD. Review of nanomaterials in dentistry: interactions with the oral microenvironment, clinical applications, hazards, and benefits. ACS NANO 2015; 9:2255-2289. [PMID: 25625290 DOI: 10.1021/nn505015e] [Citation(s) in RCA: 132] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Interest in the use of engineered nanomaterials (ENMs) as either nanomedicines or dental materials/devices in clinical dentistry is growing. This review aims to detail the ultrafine structure, chemical composition, and reactivity of dental tissues in the context of interactions with ENMs, including the saliva, pellicle layer, and oral biofilm; then describes the applications of ENMs in dentistry in context with beneficial clinical outcomes versus potential risks. The flow rate and quality of saliva are likely to influence the behavior of ENMs in the oral cavity, but how the protein corona formed on the ENMs will alter bioavailability, or interact with the structure and proteins of the pellicle layer, as well as microbes in the biofilm, remains unclear. The tooth enamel is a dense crystalline structure that is likely to act as a barrier to ENM penetration, but underlying dentinal tubules are not. Consequently, ENMs may be used to strengthen dentine or regenerate pulp tissue. ENMs have dental applications as antibacterials for infection control, as nanofillers to improve the mechanical and bioactive properties of restoration materials, and as novel coatings on dental implants. Dentifrices and some related personal care products are already available for oral health applications. Overall, the clinical benefits generally outweigh the hazards of using ENMs in the oral cavity, and the latter should not prevent the responsible innovation of nanotechnology in dentistry. However, the clinical safety regulations for dental materials have not been specifically updated for ENMs, and some guidance on occupational health for practitioners is also needed. Knowledge gaps for future research include the formation of protein corona in the oral cavity, ENM diffusion through clinically relevant biofilms, and mechanistic investigations on how ENMs strengthen the tooth structure.
Collapse
Affiliation(s)
| | - Tracy De Peralta
- ‡Plymouth University Peninsula Dental School, University of Plymouth, John Bull Building, Tamar Science Park, Plymouth PL6 8BU, U.K
| | - Christopher J Tredwin
- ‡Plymouth University Peninsula Dental School, University of Plymouth, John Bull Building, Tamar Science Park, Plymouth PL6 8BU, U.K
| | | |
Collapse
|
7
|
Effects of calcium phosphate nanocrystals on osseointegration of titanium implant in irradiated bone. BIOMED RESEARCH INTERNATIONAL 2015; 2015:783894. [PMID: 25685809 PMCID: PMC4317600 DOI: 10.1155/2015/783894] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2014] [Accepted: 10/08/2014] [Indexed: 01/26/2023]
Abstract
Radiotherapy may compromise the integration of implant and cause implant loss. Implant surface modifications have the possibility of promoting cell attachment, cell growth, and bone formation which ultimately enhance the osseointegration process. The present study aimed to investigate the effects of calcium phosphate nanocrystals on implant osseointegration in irradiated bone. Sixteen rabbits were randomly assigned into control and nano-CaP groups, receiving implants with dual acid-etched surface or dual acid-etched surface discretely deposited of nanoscale calcium-phosphate crystals, respectively. The left leg of all the rabbits received 15 Gy radiation, followed by implants placement one week after. Four animals in each group were sacrificed after 4 and 12 weeks, respectively. Implant stability quotient (ISQ), ratio of bone volume to total volume (BV/TV), bone growth rate, and bone-to-implant contact (BIC) were evaluated. The nano-CaP group showed significantly higher ISQ (week 12, P = 0.031) and bone growth rate (week 6, P = 0.021; week 9, P = 0.001) than that in control group. No significant differences in BV/TV and BIC were found between two groups. Titanium implant surface modified with CaP nanocrystals provides a potential alternative to improve bone healing around implant in irradiated bone.
Collapse
|
8
|
Liu XH, Wu L, Ai HJ, Han Y, Hu Y. Cytocompatibility and early osseointegration of nanoTiO2-modified Ti-24 Nb-4 Zr-7.9 Sn surfaces. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 48:256-62. [PMID: 25579921 DOI: 10.1016/j.msec.2014.12.011] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2014] [Revised: 10/29/2014] [Accepted: 12/04/2014] [Indexed: 12/27/2022]
Abstract
This study aimed to evaluate the cytocompatibility and early osseointegration of Ti-24 Nb-4 Zr-7.9 Sn (Ti-2448) surfaces that were modified with a nanoscale TiO2 coating. The coating was fabricated using a hydrothermal synthesis method to generate nanoTiO2/Ti-2448. The surface characteristics of the samples were evaluated using scanning electron microscopy (SEM), energy dispersive spectrometry (EDS) and X-ray diffraction (XRD). The cytotoxicity of the fabricated nanoTiO2/Ti-2448 was determined using MTT assays. The proliferation and alkaline phosphatase (ALP) activity of MC3T3-E1 osteoblasts cultured on nanoTiO2/Ti-2448 were compared with those cultured on Ti-2448. Disk-shaped implants were placed in Wistar rats. The histological sections were stained with haematoxylin and eosin (HE), and the histocompatibility was analysed at 4 and 12weeks post-implantation. Cylindrical implants were embedded in Japanese white rabbits, and the histological sections were stained with HE and anti-TGF-β1 to evaluate the histocompatibility and early osseointegration at 4, 12 and 26weeks post-implantation. NanoTiO2/Ti-2448 exhibited a rougher surface than did Ti-2448. NanoTiO2/Ti-2448 was determined to be non-cytotoxic. More osteoblasts and higher ALP activity were observed for nanoTiO2/Ti-2448 than Ti-2448 (p<0.05). Few inflammatory cells were detected around nanoTiO2/Ti-2448, and the expression of TGF-β1 on nanoTiO2/Ti-2448 peaked at earlier time than that on Ti-2448. The results indicate that the cytocompatibility and early osseointegration were enhanced by the nanoTiO2 coating.
Collapse
Affiliation(s)
- X H Liu
- Department of Prosthodontics, China Medical University School of Stomatology, Shenyang, People's Republic of China
| | - L Wu
- Department of Prosthodontics, China Medical University School of Stomatology, Shenyang, People's Republic of China.
| | - H J Ai
- Department of Prosthodontics, China Medical University School of Stomatology, Shenyang, People's Republic of China
| | - Y Han
- State Key laboratory for Mechanical Behaviour of Materials, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Y Hu
- Department of Prosthodontics, China Medical University School of Stomatology, Shenyang, People's Republic of China
| |
Collapse
|
9
|
Wu K, Song W, Zhao L, Liu M, Yan J, Andersen MØ, Kjems J, Gao S, Zhang Y. MicroRNA functionalized microporous titanium oxide surface by lyophilization with enhanced osteogenic activity. ACS APPLIED MATERIALS & INTERFACES 2013; 5:2733-2744. [PMID: 23459382 DOI: 10.1021/am400374c] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Developing biomedical titanium (Ti) implants with high osteogenic ability and consequent rigid osseointegration is a constant requirement from the clinic. In this study, we fabricate novel miRNA functionalized microporous Ti implants by lyophilizing miRNA lipoplexes onto a microporous titanium oxide surface formed by microarc oxidation (MAO). The microporous titanium oxide surface provides a larger surface area for miRNA loading and enables spatial retention of the miRNAs within the pores until cellular delivery. The loading of lipoplexes into the micropores on the MAO Ti surface is facilitated by the superhydrophilicity and Ti-OH groups gathering of the MAO surface after UV irradiation followed by lyophilization. A high miRNA transfection efficiency was observed in mesenchymal stem cells (MSCs) seeded onto the miRNA functionalized surface with no apparent cytotoxicity. When functionalizing the Ti surface with miR-29b that enhances osteogenic activity and antimiR-138 that inhibits miR-138 inhibition of endogenous osteogenesis, clear stimulation of MSC osteogenic differentiation was observed, in terms of up-regulating osteogenic expression and enhancing alkaline phosphatase production, collagen secretion and ECM mineralization. The novel miRNA functionalized Ti implants with enhanced osteogenic activity promisingly lead to more rapid and robust osseointegration of a clinical bone implant interface. Our study implies that lyophilization may constitute a versatile method for miRNA loading to other biomaterials with the aim of controlling cellular function.
Collapse
Affiliation(s)
- Kaimin Wu
- Department of Prosthetic Dentistry, School of Stomatology, The Fourth Military Medical University, No. 145 West Changle Road, Xi'an 710032, China
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Menicucci G, Mussano F, Schierano G, Rizzati A, Aimetti M, Gassino G, Traini T, Carossa S. Healing properties of implants inserted concomitantly with anorganic bovine bone. A histomorphometric human study. Aust Dent J 2013; 58:57-66. [PMID: 23441793 DOI: 10.1111/adj.12032] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/09/2012] [Indexed: 11/29/2022]
Abstract
BACKGROUND The present prospective, randomized, double-blind study evaluated the bone-forming process around implants inserted simultaneously with anorganic bovine bone (ABB) in sinus grafting. METHODS A total of 18 threaded mini-implants with Osseotite (O) and Nanotite (N) surfaces were placed in seven patients (nine sites). After 12 months, the implants were retrieved and processed for histological analysis. A total of 18 cutting and grinding sections were investigated with bright-field light microscopy, circularly polarized light microscopy (CPLM), confocal scanning laser microscope (CSLM), and scanning electron microscope (SEM) with energy dispersive spectrometer (EDS). RESULTS The bone-to-implant contact rate in native crestal bone was 62.6 ± 0.4% for N implants and 54.3 ± 0.5% for the O implants (p = 0.001). The collagen fibre density, as assessed by CPLM, was 79.8 ± 6.0 nm for the N group and 74.6 ± 4.6 nm for the O group (p < 0.05). Line scan EDS starting from ABB to newly formed bone showed a decrease in calcium content and an increase of carbon while phosphorus content was constant. CONCLUSIONS While the N surface improved the peri-implant endosseous healing properties in the native bone, when compared to the O surface, it did not improve the healing properties in the bone-graft area.
Collapse
Affiliation(s)
- G Menicucci
- Department of Biomedical Sciences and Human Oncology, Dental School, University of Turin, Turin, Italy
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Telleman G, Meijer HJA, Vissink A, Raghoebar GM. Short implants with a nanometer-sized CaP surface provided with either a platform-switched or platform-matched abutment connection in the posterior region: a randomized clinical trial. Clin Oral Implants Res 2012; 24:1316-24. [DOI: 10.1111/clr.12000] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/18/2012] [Indexed: 11/28/2022]
Affiliation(s)
- G. Telleman
- Department of Oral and Maxillofacial Surgery and Maxillofacial Prosthetics; University Medical Center Groningen and University of Groningen; Groningen The Netherlands
- Department of Fixed and Removable Prosthodontics; Centre for Dentistry and Oral Hygiene; University Medical Center Groningen and University of Groningen; Groningen The Netherlands
| | - H. J. A. Meijer
- Department of Oral and Maxillofacial Surgery and Maxillofacial Prosthetics; University Medical Center Groningen and University of Groningen; Groningen The Netherlands
- Department of Fixed and Removable Prosthodontics; Centre for Dentistry and Oral Hygiene; University Medical Center Groningen and University of Groningen; Groningen The Netherlands
| | - A. Vissink
- Department of Oral and Maxillofacial Surgery and Maxillofacial Prosthetics; University Medical Center Groningen and University of Groningen; Groningen The Netherlands
| | - G. M. Raghoebar
- Department of Oral and Maxillofacial Surgery and Maxillofacial Prosthetics; University Medical Center Groningen and University of Groningen; Groningen The Netherlands
| |
Collapse
|
12
|
Telleman G, Raghoebar GM, Vissink A, Meijer HJ. Impact of Platform Switching on Peri-Implant Bone Remodeling around Short Implants in the Posterior Region, 1-Year Results from a Split-Mouth Clinical Trial. Clin Implant Dent Relat Res 2012; 16:70-80. [DOI: 10.1111/j.1708-8208.2012.00461.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
13
|
Cairo F, Sanz I, Matesanz P, Nieri M, Pagliaro U. Quality of reporting of randomized clinical trials in implant dentistry. A systematic review on critical aspects in design, outcome assessment and clinical relevance. J Clin Periodontol 2012; 39 Suppl 12:81-107. [DOI: 10.1111/j.1600-051x.2011.01839.x] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Francesco Cairo
- Department of Periodontology; University of Florence; Florence; Italy
| | - Ignacio Sanz
- Department of Periodontology; Universidad Complutense ; de; Madrid; Madrid; Spain
| | - Paula Matesanz
- Department of Periodontology; Universidad Complutense ; de; Madrid; Madrid; Spain
| | - Michele Nieri
- Department of Periodontology; University of Florence; Florence; Italy
| | - Umberto Pagliaro
- Department of Periodontology; University of Florence; Florence; Italy
| |
Collapse
|
14
|
Abrahamsson I, Linder E, Larsson L, Berglundh T. Deposition of nanometer scaled calcium-phosphate crystals to implants with a dual acid-etched surface does not improve early tissue integration. Clin Oral Implants Res 2012; 24:57-62. [DOI: 10.1111/j.1600-0501.2012.02424.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/05/2012] [Indexed: 11/27/2022]
Affiliation(s)
- Ingemar Abrahamsson
- Department of Periodontology; The Sahlgrenska Academy at Göteborg University; Göteborg; Sweden
| | - Elena Linder
- Department of Periodontology; The Sahlgrenska Academy at Göteborg University; Göteborg; Sweden
| | - Lena Larsson
- Department of Periodontology; The Sahlgrenska Academy at Göteborg University; Göteborg; Sweden
| | - Tord Berglundh
- Department of Periodontology; The Sahlgrenska Academy at Göteborg University; Göteborg; Sweden
| |
Collapse
|
15
|
Alghamdi HS, van Oirschot BAJA, Bosco R, van den Beucken JJJP, Aldosari AAF, Anil S, Jansen JA. Biological response to titanium implants coated with nanocrystals calcium phosphate or type 1 collagen in a dog model. Clin Oral Implants Res 2012; 24:475-83. [PMID: 22276577 DOI: 10.1111/j.1600-0501.2011.02409.x] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/18/2011] [Indexed: 01/08/2023]
Abstract
OBJECTIVE The current study aimed to evaluate the osteogenic potential of electrosprayed organic and non-organic surface coatings in a gap-implant model over 4 and 12 weeks of implantation into the dog mandible. MATERIAL AND METHODS Sixteen Beagle dogs received experimental titanium implants in the mandible 3 months after removal of left premolars (P2, P3 and P4). Three types of implants were installed in each animal: non-coated implant, nano-CaP coated implant and implant with type 1 collagen coating. Both micro-CT and histomorphometry were used to evaluate peri-implant bone response after implantation periods of 4 and 12 weeks. The bone area percentage was assessed histomorphometrically in three different zones (inner: 0-300 μm; middle: 300-600 μm; and outer: 600-1000 μm) around the implant surface. Bone-bridging of the gap was also calculated for each sample. RESULTS Four weeks after implantation, nano-CaP and collagen-coated implants showed significantly higher bone volume (BV) in the inner zone compared with non-coated implants (P < 0.05 and P < 0.01). After 12 weeks, histomorphometric analysis showed comparable amounts of BV between all experimental groups. Also, no significant difference was found in the BV, as measured using micro-CT, between the implant groups. Absolute bone ingrowth measurements were highest for collagen-coated implants, but these differences were not significant. CONCLUSION The obtained data failed to provide a consistent favourable effect on bone formation of the collagen coating over 3 months of implantation. It is concluded that the source of the collagen as well as the limited osseous environment overshadowed a possible effect of the applied implant surface modifications. Similarly, the tested nano-apatite surface coating did not improve peri-implant bone ingrowth into a gap-implant model.
Collapse
Affiliation(s)
- Hamdan S Alghamdi
- Department of Biomaterials, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
16
|
Browaeys H, Vandeweghe S, Johansson CB, Jimbo R, Deschepper E, De Bruyn H. The histological evaluation of osseointegration of surface enhanced microimplants immediately loaded in conjunction with sinuslifting in humans. Clin Oral Implants Res 2012; 24:36-44. [DOI: 10.1111/j.1600-0501.2011.02398.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/19/2011] [Indexed: 11/30/2022]
Affiliation(s)
- Hilde Browaeys
- Department of Oral and Maxillofacial Surgery; Dental School; Faculty of Medicine and Health Sciences; University of Ghent; University Hospital Ghent; Ghent; Belgium
| | | | - Carina B. Johansson
- Department of Prosthodontics/Dental Materials Science; Institute of Odontology; University of Gothenburg; The Sahlgrenska Academy; Göteborg; Sweden
| | - Ryo Jimbo
- Department of Prosthodontics; Faculty of Odontology; Malmö University; Malmö; Sweden
| | - Ellen Deschepper
- Biostatistics Unit; Faculty of Medicine and Health Sciences; University of Ghent; University Hospital Ghent; Ghent; Belgium
| | | |
Collapse
|
17
|
Bone healing of commercial oral implants with RGD immobilization through electrodeposited poly(ethylene glycol) in rabbit cancellous bone. Acta Biomater 2011; 7:3222-9. [PMID: 21549863 DOI: 10.1016/j.actbio.2011.04.015] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2011] [Revised: 02/22/2011] [Accepted: 04/19/2011] [Indexed: 11/23/2022]
Abstract
Immobilization of RGD peptides on titanium (Ti) surfaces enhances implant bone healing by promoting early osteoblastic cell attachment and subsequent differentiation by facilitating integrin binding. Our previous studies have demonstrated the efficacy of RGD peptide immobilization on Ti surfaces through the electrodeposition of poly(ethylene glycol) (PEG) (RGD/PEG/Ti), which exhibited good chemical stability and bonding. The RGD/PEG/Ti surface promoted differentiation and mineralization of pre-osteoblasts. This study investigated the in vivo bone healing capacity of the RGD/PEG/Ti surface for biomedical application as a more osteoconductive implant surface in dentistry. The RGD/PEG/Ti surface was produced on an osteoconductive implant surface, i.e. the grit blasted micro-rough surface of a commercial oral implant. The osteoconductivity of the RGD/PEG/Ti surface was compared by histomorphometric evaluation with an RGD peptide-coated surface obtained by simple adsorption in rabbit cancellous bone after 2 and 4 weeks healing. The RGD/PEG/Ti implants displayed a high degree of direct bone apposition in cancellous bone and achieved greater active bone apposition, even in areas of poor surrounding bone. Significant increases in the bone to implant contact percentage were observed for RGD/PEG/Ti implants compared with RGD-coated Ti implants obtained by simple adsorption both after 2 and 4 weeks healing (P<0.05). These results demonstrate that RGD peptide immobilization on a Ti surface through electrodeposited PEG may be an effective method for enhancing bone healing with commercial micro-rough surface oral implants in cancellous bone by achieving rapid bone apposition on the implant surface.
Collapse
|
18
|
Palaiologou A, Stoute D, Fan Y, Lallier TE. Altered cell motility and attachment with titanium surface modifications. J Periodontol 2011; 83:90-100. [PMID: 21486180 DOI: 10.1902/jop.2011.100733] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Titanium implants are widely used in dentistry to replace lost teeth. Various surface modifications have been used to improve implant retention and osseointegration. This study is designed to compare the ability of three titanium surfaces to promote cell attachment and cell motility of cells relevant to periodontal tissues. METHODS Three clinically relevant surfaces were tested: 1) machined titanium; 2) a titanium surface roughened through acid etching (dual thermal-etched titanium [DTET]); and 3) a titanium surface roughened with nanometer-scale calcium phosphate deposition (nanoscale calcium phosphate-impregnated titanium [NCPIT]). Cell attachment and migration were examined for four cell types: rat osteosarcoma cells, human osteoblasts, and gingival and periodontal ligament (PDL) fibroblasts. RESULTS All four cell types attached to each of the three titanium surfaces equally by 2 hours, and the PDL and gingival fibroblasts generally displayed less attachment than the osteosarcoma cells and osteoblasts. The cells displayed differential motility and long-term attachment to each of the titanium surfaces. Osteosarcoma cells displayed preferential motility on NCPIT, whereas PDL fibroblasts were more motile on machined titanium, and gingival fibroblasts moved more rapidly on both DTET and NCPIT. Osteoblasts displayed little motility on any of the titanium surfaces and lost viability on NCPIT after 24 hours. Gingival fibroblasts lost attachment to machined titanium. CONCLUSIONS Periodontal cells displayed differential motility and long-term attachment to titanium surfaces. Selective modification of titanium surface properties in various regions of an implant may be useful in guiding specific cell populations to specific locations where they might best aid in osseointegration and soft tissue remodeling.
Collapse
Affiliation(s)
- Archontia Palaiologou
- Department of Periodontics, Louisiana State University Health Science Center, School of Dentistry, New Orleans, LA 70119, USA.
| | | | | | | |
Collapse
|
19
|
Coelho PG, Granato R, Marin C, Jimbo R, Lin S, Witek L, Suzuki M, Bonfante EA. Effect of Si addition on Ca- and P-impregnated implant surfaces with nanometer-scale roughness: an experimental study in dogs. Clin Oral Implants Res 2011; 23:373-8. [DOI: 10.1111/j.1600-0501.2010.02150.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
20
|
Svanborg L, Hoffman M, Andersson M, Currie F, Kjellin P, Wennerberg A. The effect of hydroxyapatite nanocrystals on early bone formation surrounding dental implants. Int J Oral Maxillofac Surg 2011; 40:308-15. [DOI: 10.1016/j.ijom.2010.10.010] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2010] [Revised: 10/05/2010] [Accepted: 10/07/2010] [Indexed: 10/18/2022]
|