1
|
Maneiro Lojo J, Alonso Pérez-Barquero J, García-Sala Bonmatí F, Agustín-Panadero R, Yilmaz B, Revilla-León M. Influence of print orientation on the accuracy (trueness and precision) of diagnostic casts manufactured with a daylight polymer printer. J Prosthet Dent 2024; 132:1314-1322. [PMID: 36906414 DOI: 10.1016/j.prosdent.2023.01.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 01/30/2023] [Accepted: 01/31/2023] [Indexed: 03/11/2023]
Abstract
STATEMENT OF PROBLEM Print orientation may affect the manufacturing accuracy of vat-polymerized diagnostic casts. However, its influence should be analyzed based on the manufacturing trinomial (technology, printer, and material) and printing protocol used to manufacture the casts. PURPOSE The purpose of this in vitro study was to measure the influence of different print orientations on the manufacturing accuracy of vat-polymerized polymer diagnostic casts. MATERIAL AND METHODS A standard tessellation language (STL) reference file containing a maxillary virtual cast was used to manufacture all specimens using a vat-polymerization daylight polymer printer (Photon mono SE. LCD 2K) and a model resin (Phrozen Aqua Gray 4K). All specimens were manufactured using the same printing parameters, except for print orientation. Five groups were created depending on the print orientation: 0, 22.5, 45, 67.5, and 90 degrees (n=10). Each specimen was digitized using a desktop scanner. The discrepancy between the reference file and each of the digitized printed casts was measured using the Euclidean measurements and root mean square (RMS) error (Geomagic Wrap v.2017). Independent (unpaired) sample t tests and multiple pairwise comparisons using the Bonferroni test were used to analyze the trueness of the Euclidean distances and RMS data. Precision was assessed using the Levene test (α=.05). RESULTS In terms of Euclidean measurements, significant differences in trueness and precision values were found among the groups tested (P<.001). The 22.5- and 45-degree groups resulted in the best trueness values, and the 67.5-degree group had the lowest trueness value. The 0- and 90-degree groups led to the best precision values, while the 22.5-, 45-, and 67.5-degree groups showed the lowest precision values. Analyzing the RMS error calculations, significant differences in trueness and precision values were found among the groups tested (P<.001). The 22.5-degree group had the best trueness value, and the 90-degree group resulted in the lowest trueness value among the groups. The 67.5-degree group led to the best precision value, and the 90-degree group to the lowest precision value among the groups. CONCLUSIONS Print orientation influenced the accuracy of diagnostic casts fabricated by using the selected printer and material. However, all specimens had clinically acceptable manufacturing accuracy ranging between 92 μm and 131 μm.
Collapse
Affiliation(s)
- Jesús Maneiro Lojo
- Post-Graduate Specialist in Advanced-Prosthodontics, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Jorge Alonso Pérez-Barquero
- Adjunct Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Fernando García-Sala Bonmatí
- Adjunct Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Rubén Agustín-Panadero
- Associate Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| | - Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Faculty and Director of Research and Digital Dentistry, Kois Center, Seattle, Wash; Adjunct Professor, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Mass.
| |
Collapse
|
2
|
Shahin SY, Nassar EA, Gad MM. 3D-printed one-piece versus two-piece orthodontic clear aligner attachments bonded with provisional crowns: A proof of concept. J Dent 2024; 151:105406. [PMID: 39427961 DOI: 10.1016/j.jdent.2024.105406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 10/07/2024] [Accepted: 10/12/2024] [Indexed: 10/22/2024] Open
Abstract
OBJECTIVES This study aimed to introduce a novel technique for fabricating provisional crowns integrated as a single unit with aligner attachments. METHODS A total of 60 crowns with attachments were prepared: 20 conventional (Protemp) and 40 3D-printed (20 bonded with attachments; 20 integrated with composite attachments as a single unit) using NextDent resin. Two central incisors were scanned (once without attachments and once with attachments) to create STL files for specimen printing. Half of the specimens (30, n = 10 per group) underwent thermal cycling (5000 cycles). Shear bond strengths (MPa) were evaluated using a universal testing machine. The debonded areas and attachment failures were analyzed to determine the fracture type. Data analyses were performed using ANOVA and post hoc Tukey tests (α = 0.05). RESULTS The 3D-printed specimens showed higher strength values than the bonded attachments per group (P < 0.001). The 3D-printed crowns with attachments demonstrated the highest strength (12.39 ± 1.92 MPa). Thermal cycling significantly decreased the bond strength of the attachments (P < 0.001), except in the 3D-printed crowns with composite attachments as a single unit, which showed no significant change after thermal cycling (P = 0.643). In the bonded attachment groups, the adhesive type was the predominant failure mode, while in the 3D-printed groups, attachment fractures were the primary cause of failure. CONCLUSION The 3D-printed provisional crowns with attachments have high strength and is clinically appropriate for orthodontic treatment when temporization of teeth is indicated. CLINICAL SIGNIFICANCE The developed technique for fabricating 3D-printed provisional restorations with orthodontics attachments as a single unit is a promising approach. The technique may be incorporated into the digital orthodontic treatment workflow when temporization is indicated.
Collapse
Affiliation(s)
- Suliman Y Shahin
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P. O. Box 1982, Dammam 31441, Saudi Arabia
| | - Essam A Nassar
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P. O. Box 1982, Dammam 31441, Saudi Arabia
| | - Mohammed M Gad
- Department of substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P. O. Box 1982, Dammam 31441, Saudi Arabia.
| |
Collapse
|
3
|
Mou Z, Zhong J, Wang F, Alhotan A, Zhu P, Li P, Huang J. Zirconia crowns manufactured using digital light processing: Effects of build angle and layer thickness on the accuracy. J Dent 2024; 151:105359. [PMID: 39362298 DOI: 10.1016/j.jdent.2024.105359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 09/09/2024] [Accepted: 09/16/2024] [Indexed: 10/05/2024] Open
Abstract
OBJECTIVES This study investigated the effects of build angle and layer thickness on the trueness and precision of zirconia crowns manufactured using digital light processing (DLP) technology. MATERIALS AND METHODS Single crowns were fabricated from zirconia using DLP technology. The crowns were manufactured with three different representative build angles (0°, 45°, and 90°) and two different layer thicknesses (30 μm and 50 μm). After printing, the specimens were non-contact-scanned, and their accuracy was assessed using a 3D analysis software. Root mean square (RMS) values were used to determine trueness and precision. Color maps were generated to detect deviations within the specimens. Statistical analyses were conducted using two-way ANOVA. RESULTS Build angle and layer thickness significantly affected trueness and precision (p < 0.05). At a 30-μm layer thickness, the crowns printed at angles of 0° (32.2 ± 3.2 μm) and 45° (33.9 ± 2.4 μm) demonstrated the best marginal trueness compared to those in other groups (p < 0.05). Notably, those printed at an angle of 90° exhibited the best intaglio surface trueness (37.4 ± 4.0 μm). At a 50-μm layer thickness, the crowns printed at an angle of 90° exhibited the lowest accuracy concerning marginal and intaglio surface aspects (27.7 ± 8.2 μm). CONCLUSIONS Both the build angle and layer thickness significantly affected the dimensional accuracy of DLP-printed zirconia crowns, with the 30-μm layer thickness offering superior trueness. Optimal results were achieved using build angles of 0° and 45° in conjunction with thinner layers, minimizing marginal defects. CLINICAL SIGNIFICANCE All zirconia crowns produced at different build angles and layer thicknesses satisfied clinical requirements. Specific combinations of these factors realized the fabrication of single crowns that possessed the highest accuracy.
Collapse
Affiliation(s)
- Zewen Mou
- Department of Prosthodontics, School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou 510180, China; Guangzhou Key Laboratory of Basic and Applied Research of Oral Regenerative Medicine, Guangzhou Medical University, Guangzhou 510180, China
| | - Jimeng Zhong
- School of Materials and Energy, Foshan University, Foshan 528225, China; Shenzhen Adventure Tech Co. Ltd., Shenzhen 518053, PR China
| | - Feng Wang
- Suzhou Laboratory, Suzhou 215000, China
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh 12372, Saudi Arabia
| | - Pengfei Zhu
- Shenzhen Adventure Tech Co. Ltd., Shenzhen 518053, PR China; Foshan (Southern China) Institute for New Materials, Foshan 528000, PR China.
| | - Ping Li
- Department of Prosthodontics, School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou 510180, China; Guangzhou Key Laboratory of Basic and Applied Research of Oral Regenerative Medicine, Guangzhou Medical University, Guangzhou 510180, China.
| | - Jiangyong Huang
- Department of Prosthodontics, School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou 510180, China; Guangzhou Key Laboratory of Basic and Applied Research of Oral Regenerative Medicine, Guangzhou Medical University, Guangzhou 510180, China.
| |
Collapse
|
4
|
Cagna DR, Donovan TE, McKee JR, Metz JE, Marzola R, Murphy KG, Troeltzsch M. Annual review of selected scientific literature: A report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2024; 132:1133-1214. [PMID: 39489673 DOI: 10.1016/j.prosdent.2024.10.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2024] [Accepted: 10/21/2024] [Indexed: 11/05/2024]
Abstract
The Scientific Investigation Committee of the American Academy of Restorative Dentistry offers this review of select 2023 dental literature to briefly touch on several topics of interest to modern restorative dentistry. Each committee member brings discipline-specific expertize in their subject areas that include (in order of appearance here): prosthodontics; periodontics, alveolar bone, and peri-implant tissues; dental materials and therapeutics; occlusion and temporomandibular disorders; sleep-related breathing disorders; oral medicine, oral and maxillofacial surgery, and oral radiology; and dental caries and cariology. The authors have focused their efforts on presenting information likely to influence the daily dental treatment decisions of the reader with an emphasis on current innovations, new materials and processes, emerging technology, and future trends in dentistry. With the overwhelming volume of literature published daily in dentistry and related disciplines, this review cannot be comprehensive. Instead, its purpose is to inform and update interested readers and provide valuable resource material for those willing to subsequently pursue greater detail on their own. Our intent remains to assist colleagues in navigating the tremendous volume of newly minted information produced annually. Finally, we hope readers find this work helpful in providing evidence-based care to patients seeking healthier and happier lives.
Collapse
Affiliation(s)
- David R Cagna
- Professor (adjunct) and Postdoctoral Program Consultant, Department of Prosthodontics, University of Tennessee Health Sciences Center College of Dentistry, Memphis, Tenn.
| | - Terence E Donovan
- Professor, Department of Comprehensive Oral Health, University of North Carolina School of Dentistry, Chapel Hill, NC
| | | | - James E Metz
- Private practice, Restorative Dentistry, Columbus, Ohio; Assistant Professor (adjunct), Department of Prosthodontics, University of Tennessee Health Science Center College of Dentistry, Memphis, Tenn.; Clinical Professor, Marshall University's Joan C. Edwards School of Medicine, Department of Dentistry & Oral Surgery, Huntington, WV
| | | | - Kevin G Murphy
- Associate Clinical Professor, Department of Periodontics, University of Maryland College of Dentistry, Baltimore, MD
| | - Matthias Troeltzsch
- Private practice, Oral, Maxillofacial, and Facial Plastic Surgery, Ansbach, Germany; and Department of Oral and Maxillofacial Surgery, Ludwig-Maximilian University of Munich, Munich, Germany
| |
Collapse
|
5
|
Piedra-Cascón W, Pérez-López J, Veiga-López B, Oteo-Morilla C, Pose-Rodriguez JM, Gallas-Torreira M. Influence of base designs on the manufacturing accuracy of vat-polymerized diagnostic casts using two different technologies. J Prosthet Dent 2024; 132:453.e1-453.e9. [PMID: 38714457 DOI: 10.1016/j.prosdent.2024.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Revised: 04/02/2024] [Accepted: 04/04/2024] [Indexed: 05/09/2024]
Abstract
STATEMENT OF PROBLEM Diagnostic casts can incorporate different base designs and be manufactured using different vat-polymerization technologies. However, the influence of the interrelation between the base design and the 3D printing technology on the casts' final accuracy remains unclear. PURPOSE The purpose of this in vitro study was to assess the influence of different base designs of 3D printed casts on the accuracy of 2 vat-polymerization technologies. MATERIAL AND METHODS A digital maxillary cast was obtained and used to generate 3 different base designs: solid (S group), honeycombed (HC group), and hollow (H group). The HC and H groups were subdivided based on the wall thickness of the cast design, resulting in 2 subgroups with thicknesses of 1 mm (HC1 and H1) and 2 mm (HC2 and H2) (N=100, n=10). Eleven reference cubes were added to each specimen for subsequent measurements. Specimens were manufactured by using 2 vat-polymerization 3D printers: Nextdent 5100 (ND group) and Sonic Mini 4K (SM4K group) and a resin material suitable for both 3D printers (Nextdent Model 2.0). A coordinate measuring machine quantified the linear and 3-dimensional discrepancies between the digital cast and each reference specimen. Trueness was defined as the average absolute dimensional discrepancy between the virtual cast and the specimens produced through additive manufacturing (AM), while precision was delineated as the standard deviation in dimensional discrepancies between the digital cast and the AM specimens. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U pairwise comparison tests (α=.05). RESULTS For the NextDent group the trueness ranged from 21.83 µm to 28.35 µm, and the precision ranged from 17.82 µm to 37.70 µm. For the Phrozen group, the trueness ranged from 45.15 µm to 64.51 µm, and the precision ranged from 33.51 µm to 48.92 µm. The Kruskal-Wallis test showed significant differences on the x-, y-, and z-axes and in the 3D discrepancy (all P<.001). On the x-axis, the Mann-Whitney U test showed significant differences for the Phrozen group between the H-2 and H-1 groups (P=.001), H-2 and S groups (P<.001), and HC-2 and S groups (P=.012). On the y-axis, significant differences were found in the Phrozen group between the H-2 and H-1 groups (P=.001), the H-2 and S, H-1 and HC-1, and HC-1 and S groups (P<.001), the H-1 and HC-2 groups (P=.007), and the HC-2 and S groups (P=.009). The NextDent group exhibited significant differences, particularly among the HC-1 and H-2 groups (P=.004), H-1 (P=.020), and HC-2 (P=.001) groups; and on the z-axis significant differences were found in the Phrozen group between the H-2 and H-1 and S groups and the HC-2 group and H-1 and S groups (both P<.001). In the NextDent group, significant differences were found between the H-2 and HC-2 (P=.047) and HC-1 (P=.028) groups. For the 3D discrepancy analysis, significant differences were found in the Phrozen group between the H-2 and H-1 and S groups (P<.001), the H-1 and HC-2 groups (P=.001), the S and HC-1 and HC-2 groups (P<.001), and the H-1 and HC-1 groups (P=.002). In the NextDent group, significant differences were observed between the H-2 and HC-1 groups (P=.012). CONCLUSIONS The accuracy of digital casts depends on the manufacturing trinomial and base design of the casts. The honeycomb and hollow based designs provided the highest accuracy in the NextDent and Phrozen groups respectively for the material polymer tested. All specimens fell in the clinically acceptable range.
Collapse
Affiliation(s)
- Wenceslao Piedra-Cascón
- Doctoral student, Doctoral Program in Dental Science, Stomatology Area, Department of Surgery and Medical-Surgery Specialities, University of Santiago de Compostela (USC), Santiago de Compostela, Spain; Affiliate Faculty, Esthetic Dentistry Program, Complutense University of Madrid (UCM), Madrid, Spain; Private practice, Oviedo, Spain; and Researcher, Movumtech, Madrid, Spain.
| | | | | | - Carlos Oteo-Morilla
- Affiliate Faculty Graduate in Esthetic Dentistry Program, Complutense University of Madrid (UCM), Madrid, Spain; and Private practice, Madrid, Spain
| | - Jose Manuel Pose-Rodriguez
- Associated Lecturer, Adult Comprehensive Dental Clinic, Stomatology Area, Department of Surgery and Medical-Surgery Specialities, Digital Dentistry Unit of the School of Dentistry, Faculty of Medicine and Dentistry, University of Santiago de Compostela (USC), Santiago de Compostela, Spain
| | - Mercedes Gallas-Torreira
- Senior Lecturer, Planning and Management in Dental Clinics, Stomatology Area, Department of Surgery and Medical-Surgery Specialities, Digital Dentistry Unit of the School of Dentistry, Faculty of Medicine and Dentistry, University of Santiago de Compostela (USC), Santiago de Compostela, Spain
| |
Collapse
|
6
|
Diken Türksayar AA, Diker B. Effect of layer thickness and polishing on wear resistance of additively manufactured occlusal splints. J Dent 2024; 146:105101. [PMID: 38801940 DOI: 10.1016/j.jdent.2024.105101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Revised: 05/20/2024] [Accepted: 05/24/2024] [Indexed: 05/29/2024] Open
Abstract
OBJECTIVE To evaluate the effect of polishing and layering thickness on the wear resistance of 3D-printed occlusal splint materials. METHODS Specimens with 3 different layer thicknesses (50, 75, 100 µm) were produced in the form of a disc 3 mm thick using V-Print splint resin on a 3D-printer with digital light processing technology. (n = 16 for each thickness) All specimens were washed and cured according to the manufacturer's instructions. Half of the specimens of each layer thickness were polished with silicon carbide papers. All specimens were subjected to 120.000 cycles of a chewing simulator for 2-body wear tests. Before and after the wear test, the specimens were scanned with a laser scanner, and the images were overlaid using a 3D analysis program and the volume loss was calculated. The wear patterns of the specimens were examined under a scanning electron microscope. Statistical evaluation was performed using a Shapiro-Wilk test, 2-way ANOVA, 1-way ANOVA, and Tukey post hoc test (α = 0.05). RESULTS While polishing had a significant effect (p = 0.003) on the wear volume of the occlusal splints, layer thickness (p = 0.105) and their interaction between polishing and layer thickness (p = 0.620) did not significantly affect the wear volume. Regardless of the polishing, the lowest mean wear was observed for D50 (0.064 mm3), followed by D75 (0.078 mm3), and D100 (0.096 mm3). However, a significant difference was observed only between polished D50 and unpolished D100. CONCLUSION The polished 3D-printed occlusal splint resin showed higher wear resistance than the unpolished one, regardless of the layer thickness. CLINICAL SIGNIFICANCE Since different layer thicknesses of 50 µm and greater had no effect on the wear resistance of the material, a layer thickness of 100 µm may be preferred for faster printing. However, polishing occlusal splints may reduce the amount of wear and improve clinical performance.
Collapse
Affiliation(s)
- Almira Ada Diken Türksayar
- Department of Prosthodontics, Faculty of Dentistry, Biruni University, Merkezefendi, 75 Sk No:1-13 M. G, 34015 Zeytinburnu, Istanbul, Turkey.
| | - Burcu Diker
- Department of Prosthodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey
| |
Collapse
|
7
|
Lassila L, Mangoush E, He J, Vallittu PK, Garoushi S. Effect of Post-Printing Conditions on the Mechanical and Optical Properties of 3D-Printed Dental Resin. Polymers (Basel) 2024; 16:1713. [PMID: 38932063 PMCID: PMC11207275 DOI: 10.3390/polym16121713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 06/05/2024] [Accepted: 06/13/2024] [Indexed: 06/28/2024] Open
Abstract
This study aimed to evaluate the flexural strength (FS), surface wear, and optical properties of 3D-printed dental resins subjected to different post-printing conditions. A total of 240 specimens (2 × 2 × 25 mm³) were 3D-printed using resin materials for permanent (VaresoSmile Crown Plus) VSC and temporary (VaresoSmile Temp) VST restorations. Specimens underwent five post-printing conditions: no post-printing cure; post-cured in a Form Cure curing unit; Visio Beta Vacuum; Ivoclar Targis; or heat-cured (150 °C) for 30 min. Each group of specimens (n = 24) was tested either directly after post-curing, after 24 h of dry storage, or following hydrothermal accelerated aging in boiling water for 16 h. The three-point bending test was used to evaluate the FS. The two-body wear test was performed on 50 disc-shaped specimens (n = 5/group). Surface gloss and translucency were measured for permanent VSC specimens (n = 5/group). SEM/EDS and statistical analyses were performed. The Form Cure device yielded the highest FS and lowest wear depth (p < 0.05). Hydrothermal aging significantly reduced FS. There were no statistical differences in FS and wear values between materials subjected to same post-printing conditions. VSC groups exhibited similar optical properties across different post-printing treatments. Post-printing treatment conditions had a significant impact on the FS and wear of the 3D-printed resin, while optical properties remained unaffected.
Collapse
Affiliation(s)
- Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterial Center—TCBC, Institute of Dentistry, University of Turku, 20520 Turku, Finland; (L.L.); (J.H.); (P.K.V.); (S.G.)
| | - Enas Mangoush
- Department of Biomaterials Science and Turku Clinical Biomaterial Center—TCBC, Institute of Dentistry, University of Turku, 20520 Turku, Finland; (L.L.); (J.H.); (P.K.V.); (S.G.)
| | - Jingwei He
- Department of Biomaterials Science and Turku Clinical Biomaterial Center—TCBC, Institute of Dentistry, University of Turku, 20520 Turku, Finland; (L.L.); (J.H.); (P.K.V.); (S.G.)
- College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640, China
| | - Pekka K. Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterial Center—TCBC, Institute of Dentistry, University of Turku, 20520 Turku, Finland; (L.L.); (J.H.); (P.K.V.); (S.G.)
- Wellbeing Services County of South-West Finland, 20014 Turku, Finland
| | - Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterial Center—TCBC, Institute of Dentistry, University of Turku, 20520 Turku, Finland; (L.L.); (J.H.); (P.K.V.); (S.G.)
| |
Collapse
|
8
|
Revilla-León M, Cascos-Sánchez R, Zeitler JM, Barmak AB, Kois JC, Gómez-Polo M. Influence of print orientation and wet-dry storage time on the intaglio accuracy of additively manufactured occlusal devices. J Prosthet Dent 2024; 131:1226-1234. [PMID: 36635137 DOI: 10.1016/j.prosdent.2022.12.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 12/06/2022] [Accepted: 12/06/2022] [Indexed: 01/11/2023]
Abstract
STATEMENT OF PROBLEM Different factors can affect the manufacturing accuracy of additively manufactured dental devices; however, the influence of print orientation and wet-dry storage time on their intaglio accuracy remains uncertain. PURPOSE The purpose of this in vitro study was to assess the effect of print orientation (0, 45, 70, and 90 degrees) and wet-dry storage time (0, 30, 60, and 90 days) on the intaglio accuracy of additively manufactured occlusal devices. MATERIAL AND METHODS An occlusal device design was obtained in a standard tessellation language (STL) file format (control file) which was used to fabricate all the specimens by using a stereolithography printer (Form 3+) and a biocompatible resin material (Dental LT Clear Resin, V2). Four groups were created based on the print orientation used to manufacture the specimens: 0, 45, 70, and 90 degrees. Each group was divided into 4 subgroups depending on the time elapsed between manufacturing and accuracy evaluation: 0, 30, 60, and 90 days. For the subgroup 0, a desktop scanner (T710) was used to digitize all the specimens. The 30-day subgroup specimens were stored for 30 days with the following daily storage protocol: 16 hours inside a dry lightproof container, followed by 8 hours in artificial saliva (1700-0305 Artificial Saliva) inside the same lightproof container. The specimens were then digitized by following the same procedures used for subgroup 0. For the subgroups 60 and 90, the identical procedures described for subgroup 30 were completed but after 60 and 90 days of storage, respectively. The reference STL file was used to measure the intaglio discrepancy with the experimental scans obtained among the different subgroups by using the root mean square error calculation. Two-way ANOVA and post hoc Tukey pairwise comparison tests were used to analyze the data (α=.05). RESULTS Print orientation (P<.001) and usage time (P<.001) were significant predictors of the trueness value obtained. Additionally, the 0-degree print orientation at day 0 group demonstrated the best trueness value among all the groups tested (P<.05). No significant trueness discrepancies were found among the 45-, 70-, and 90-degree print orientation, or among the 30, 60, and 90 days of storage. A significant precision difference was found in the variance between print orientation groups across usage time subgroups. CONCLUSIONS The print orientation and wet-dry storage times tested influenced the trueness and precision of the intaglio surfaces of the occlusal devices manufactured with the 3D printer and material selected.
Collapse
Affiliation(s)
- Marta Revilla-León
- Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Faculty and Director of Research and Digital Dentistry, Kois Center, Seattle, Wash; Affiliate Professor, Graduate Prosthodontics, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Mass
| | - Rocío Cascos-Sánchez
- Postgraduate Advanced in Implant-Prosthodontics, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain
| | | | - Abdul B Barmak
- Assistant Professor Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY
| | - John C Kois
- Founder and Director, Kois Center, Seattle, Wash; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington, Seattle, Wash; Private Practice, Seattle, Wash
| | - Miguel Gómez-Polo
- Associate Professor, Department of Conservative Dentistry and Prosthodontics, Director of postgraduate program of Advanced in Implant-Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain.
| |
Collapse
|
9
|
Espinar C, Pérez MM, Pulgar R, Leon-Cecilla A, López-López MT, Della Bona A. Influence of printing orientation on mechanical properties of aged 3D-printed restorative resins. Dent Mater 2024; 40:756-763. [PMID: 38429216 DOI: 10.1016/j.dental.2024.02.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 02/15/2024] [Accepted: 02/18/2024] [Indexed: 03/03/2024]
Abstract
OBJECTIVE To evaluate the influence of printing orientation on flexural strength (σf) and elastic modulus (E) of different 3D printing dental restorative resins. METHODS Bar-shaped specimens (n = 20) were fabricated from two SLA-printed resins (FT- Formlabs Temporary, and FP- Formlabs Permanent) and two DLP-printed resins (DFT- Detax Freeprint Temp, and GCT- GC Temporary) using two building orientations (0º and 90º). The 3D-printed structures were aged (14 d) before submitted to three-point bending in 37ºC distilled water at a crosshead speed of 1.0 ± 0.3 mm/min until fracture to calculate the σf and the E values. The fractured surfaces were evaluated using stereomicroscopy and scanning electron microscopy (SEM) following fractography principles. Data were statistically analyzed using two-way ANOVA and Tukey post-hoc (α = 0.001). RESULTS FP and FT showed significantly higher E values than DFT and GCT, irrespectively of printing orientation (p < 0.001). There was no statistical difference between the building orientations (0º and 90º) for the mean σf and E values for the resin materials evaluated. Fractographic characteristics were similar for the surface fracture from all the materials evaluated, showing typical brittle fracture behavior. SIGNIFICANCE Printing orientation did not influence of flexural strength and elastic modulus values for the 3D-printed resin structures evaluated. Surface topography was mostly governed by the 3D printer type.
Collapse
Affiliation(s)
- Cristina Espinar
- Department of Stomatology, Faculty of Dentistry, Colegio Máximo, Campus de Cartuja s/n. University of Granada, 18071 Granada, Spain
| | - María M Pérez
- Department of Optics, Faculty of Science, Campus Fuentenueva, Edificio Mecenas, s/n. University of Granada, 18071 Granada, Spain
| | - Rosa Pulgar
- Department of Stomatology, Faculty of Dentistry, Colegio Máximo, Campus de Cartuja s/n. University of Granada, 18071 Granada, Spain
| | - Alberto Leon-Cecilla
- Department of Applied physics, Faculty of Science, Campus Fuentenueva, University of Granada, 18071 Granada, Spain
| | - Modesto T López-López
- Department of Applied physics, Faculty of Science, Campus Fuentenueva, University of Granada, 18071 Granada, Spain
| | - Alvaro Della Bona
- Postgraduate Program in Dentistry, Dental School, University of Passo Fundo, Campus I, Passo Fundo, RS, Brazil.
| |
Collapse
|
10
|
Aljehani A, Nabalawi A, Hefni A, Alsefri Z, Fakhry O, Al Zaibak W, Raffa O. Effect of build orientation on the fracture resistance and marginal quality of 3D-printed anatomic provisional crowns: An in-vitro study. Saudi Dent J 2024; 36:584-590. [PMID: 38690397 PMCID: PMC11056395 DOI: 10.1016/j.sdentj.2024.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 12/29/2023] [Accepted: 01/01/2024] [Indexed: 05/02/2024] Open
Abstract
Introduction Computer-aided design and computer-aided manufacturing (CAD/CAM) technologies have been increasingly used to fabricate provisional restorations in recent years. This study assessed how build orientation influences the fracture resistance and marginal quality of 3D-printed crowns compared with milled provisional crowns. Methods The test group included 3D-printed crowns (Freeprint temp Shade A2, Detax, Ettlingen, Germany), which were further subdivided based on print orientation (0°, 45°, and 90°; n = 10 for each subgroup). The control group (n = 10) included milled crowns (Coratemp, White Peaks, Germany) with the same design as those of the test group. The margin quality of each crown was assessed at 60 × magnification using a digital stereomicroscope. A load-to-fracture test was performed by applying a force at a rate of 2 mm/min to assess fracture resistance. One sample from each subgroup was also subjected to scanning electron microscope (SEM) analysis. Results The milled group exhibited the highest fracture resistance and marginal quality. Within the printed subgroups, the 0° group showed the best mean marginal quality, whereas the 90° group showed the lowest mean marginal quality (p < 0.05). Within the test groups, the 90° group had the highest mean fracture resistance (p < 0.05). In the SEM analysis, the milled group exhibited the most homogenous boundaries, whereas among the 3D-printed subgroups, the samples printed at 0° had the best margin quality. Conclusion The manufacturing method significantly influences the marginal quality and fracture resistance. Milled crowns demonstrated superior marginal quality and fracture resistance compared to those of 3D printed crowns. Furthermore, the print orientation of 0° led to the best marginal quality, whereas printing at 90° led to the highest fracture resistance.
Collapse
Affiliation(s)
| | | | - Ahmed Hefni
- King Abdulaziz University, Faculty of Dentistry, Jeddah, Saudi Arabia
| | - Ziyad Alsefri
- King Abdulaziz University, Faculty of Dentistry, Jeddah, Saudi Arabia
| | - Omar Fakhry
- King Abdulaziz University, Faculty of Dentistry, Jeddah, Saudi Arabia
| | - Walaa Al Zaibak
- Department of Periodontics and Implants, Joele special medical center, Jeddah Saudi Arabia
| | - Ossama Raffa
- Department of Prosthodontics, King Abdulaziz Medical City, Jeddah, Saudi Arabia
| |
Collapse
|
11
|
Salazar Rios AL, Kesterke MJ, Pylant GD, Barmak AB, Kontogiorgos ED, Revilla-León M. Effect of print orientation, storage conditions, and storage time on intaglio surface accuracy of implant surgical guides fabricated by using a stereolithography technology. J Prosthet Dent 2023:S0022-3913(23)00552-8. [PMID: 37778941 DOI: 10.1016/j.prosdent.2023.08.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 08/14/2023] [Accepted: 08/16/2023] [Indexed: 10/03/2023]
Abstract
STATEMENT OF PROBLEM The accuracy of printed implant surgical guides can be affected by different factors that negatively impact the planned implant position. How print orientation, storage time, and conditions influence manufacturing accuracy remains uncertain. PURPOSE The purpose of this in vitro study was to evaluate the influence of print orientation, storage conditions, and storage time on the intaglio surface accuracy of implant surgical guides manufactured by using a stereolithography (SLA) printer. MATERIAL AND METHODS A tooth-supported maxillary implant surgical guide design (control file) was used to fabricate the specimens (N=40, n=10). Four groups were created based on the print orientation used: 0 (Group 0), 45 (Group 45), 70 (Group 70), and 90 degrees (Group 90). The specimens were fabricated using an SLA printer (Form 3B+) and a biocompatible dental resin (Surgical Guide Resin V1) following the manufacturer's recommended protocol. Each group was divided into 2 subgroups based on the storage conditions: light (L subgroup) and dark (D subgroup) settings. Each specimen was digitized by using a desktop scanner (Medit T710) at days 0, 1, 7, and 14. The control file and each digitized specimen were superimposed by using the best-fit technique with a metrology program (Geomagic Control X). The root mean square (RMS) error was used to calculate the discrepancies between the control files and specimen files. Three-way ANOVA and pairwise comparison Tukey tests were used to analyze trueness. The Levene test was used to assess precision (α=.05). RESULTS Significant trueness discrepancies were found among the groups tested (P<.001), but no significant differences were found among the subgroups (P=.100) and the storage times analyzed (P=.609). Additionally, the Tukey test showed significant RMS error mean value discrepancies between Group 0 and Group 45 (P<.001), Group 0 and Group 90 (P<.001), Group 45 and Group 70 (P<.001), and Group 70 and Group 90 (P<.001). The Levene test revealed significant SD discrepancies among the groups tested (P<.05). CONCLUSIONS The trueness and precision of the intaglio surface of the implant surgical guides manufactured by using the printer and material tested were affected by the print orientation. However, storage conditions over a 14-day period did not impact the intaglio accuracy of the specimens.
Collapse
Affiliation(s)
- Alma L Salazar Rios
- Graduate student, Graduate Program in Prosthodontics, Comprehensive Dentistry Department, School of Dentistry, Texas A&M University, Dallas, Texas
| | - Matthew J Kesterke
- Assistant Professor, Department of Orthodontics, School of Dentistry, Texas A&M University, Dallas, Texas
| | - George D Pylant
- Adjunct Professor, Department of Periodontics, School of Dentistry, Texas A&M University, Dallas, Texas
| | - Abdul B Barmak
- Associate Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY
| | - Elias D Kontogiorgos
- Clinical Professor and Director, Graduate Program in Prosthodontics, Comprehensive Dentistry Department, School of Dentistry, Texas A&M University, Dallas, Texas
| | - Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Faculty and Director of Research and Digital Dentistry, Kois Center, Seattle, Wash; Adjunct Professor, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Mass..
| |
Collapse
|
12
|
Revilla-León M, Fry E, Supaphakorn A, Barmak AB, Kois JC. Manufacturing accuracy of the intaglio surface of definitive resin-ceramic crowns fabricated at different print orientations by using a stereolithography printer. J Prosthet Dent 2023:S0022-3913(23)00267-6. [PMID: 37246096 DOI: 10.1016/j.prosdent.2023.04.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 04/11/2023] [Accepted: 04/12/2023] [Indexed: 05/30/2023]
Abstract
STATEMENT OF PROBLEM Stereolithography (SLA) procedures can be chosen for manufacturing definitive crowns; however, how the print orientation impacts the trueness and precision of the intaglio surface of the printed definitive restorations is unclear. PURPOSE The purpose of this in vitro investigation was to calculate the manufacturing accuracy of the intaglio surface of SLA definitive resin-ceramic crowns fabricated at varying print orientations (0, 45, 75, or 90 degrees). MATERIAL AND METHODS The standard tessellation language (STL) file of an anatomic contour molar crown was obtained and used to fabricate all the crowns by using a definitive resin-ceramic material (Permanent Crown) and an SLA printer (Form 3B+). Four groups were developed depending on the print orientation selected to manufacture the crowns: 0-, 45-, 70-, and 90-degree print orientation (n=30). Each crown specimen was digitized without the use of scanning powder by using a desktop scanner (T710). The crown design file was determined as the reference (control) group and used to calculate the fabricating trueness and precision of the intaglio surface of the specimens using the root mean square (RMS) error computation. Trueness data were examined by using 1-way ANOVA and post hoc pairwise multiple comparison Tukey tests, while precision data were analyzed using the Levene test (α=.05). RESULTS The mean ±standard deviation RMS error discrepancies ranged from 37 ±3 μm to 113 ±11 μm. One-way ANOVA exposed significant trueness (P<.001) differences among the groups considered in this study. Furthermore, all the print orientation groups tested were different from each other (P<.001). The 0-degree group presented the best trueness value (37 μm), while the 90-degree group obtained the worst trueness value (113 μm). The Levene test exposed significant precision differences among the groups assessed (P<.001). The 0-degree group had a significantly lower standard deviation (higher precision) (3 μm) than the other groups, with no difference among the other groups tested (P>.05). CONCLUSIONS The fabricating trueness and precision of the intaglio surface of the SLA resin-ceramic crowns was impacted by the varying print orientations assessed.
Collapse
Affiliation(s)
- Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Faculty and Director of Research and Digital Dentistry, Kois Center, Seattle, Wash; and Adjunct Professor, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Mass.
| | - Elisabeth Fry
- Director of Clinical Operations, Kois Center, Seattle, Wash
| | | | - Abdul B Barmak
- Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY
| | - John C Kois
- Director, Kois Center, Seattle, Wash; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; and Private Practice, Seattle, Wash
| |
Collapse
|