1
|
Chuhan IS, Li J, Guo Z, Shahzad H, Yaqub M. Entropy optimization of MHD non-Newtonian fluid in a wavy enclosure with double diffusive natural convection. NUMERICAL HEAT TRANSFER, PART A: APPLICATIONS 2024; 85:2703-2723. [DOI: 10.1080/10407782.2023.2228482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 06/15/2023] [Indexed: 09/22/2024]
Affiliation(s)
- Imran Shabir Chuhan
- Faculty of Science, Interdisciplinary Research Institute, Beijing University of Technology, P.R. China
| | - Jing Li
- Faculty of Science, Interdisciplinary Research Institute, Beijing University of Technology, P.R. China
| | - Ziyu Guo
- Faculty of Science, Interdisciplinary Research Institute, Beijing University of Technology, P.R. China
| | - Hasan Shahzad
- College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, P.R. China
| | - Muhammad Yaqub
- Faculty of Information Technology, Beijing University of Technology, P.R. China
| |
Collapse
|
2
|
Li X, Zou J, He Z, Sun Y, Song X, He W. The interaction between particles and vascular endothelium in blood flow. Adv Drug Deliv Rev 2024; 207:115216. [PMID: 38387770 DOI: 10.1016/j.addr.2024.115216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Revised: 01/25/2024] [Accepted: 02/14/2024] [Indexed: 02/24/2024]
Abstract
Particle-based drug delivery systems have shown promising application potential to treat human diseases; however, an incomplete understanding of their interactions with vascular endothelium in blood flow prevents their inclusion into mainstream clinical applications. The flow performance of nano/micro-sized particles in the blood are disturbed by many external/internal factors, including blood constituents, particle properties, and endothelium bioactivities, affecting the fate of particles in vivo and therapeutic effects for diseases. This review highlights how the blood constituents, hemodynamic environment and particle properties influence the interactions and particle activities in vivo. Moreover, we briefly summarized the structure and functions of endothelium and simulated devices for studying particle performance under blood flow conditions. Finally, based on particle-endothelium interactions, we propose future opportunities for novel therapeutic strategies and provide solutions to challenges in particle delivery systems for accelerating their clinical translation. This review helps provoke an increasing in-depth understanding of particle-endothelium interactions and inspires more strategies that may benefit the development of particle medicine.
Collapse
Affiliation(s)
- Xiaotong Li
- School of Pharmacy, China Pharmaceutical University, Nanjing 2111198, PR China
| | - Jiahui Zou
- School of Pharmacy, China Pharmaceutical University, Nanjing 2111198, PR China
| | - Zhongshan He
- Department of Critical Care Medicine and Department of Biotherapy, Frontiers Science Center for Disease-related Molecular Network, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu 610000, PR China
| | - Yanhua Sun
- Shandong Provincial Key Laboratory of Microparticles Drug Delivery Technology, Qilu Pharmaceutical Co., LtD., Jinan 250000, PR China
| | - Xiangrong Song
- Department of Critical Care Medicine and Department of Biotherapy, Frontiers Science Center for Disease-related Molecular Network, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu 610000, PR China.
| | - Wei He
- School of Pharmacy, China Pharmaceutical University, Nanjing 2111198, PR China.
| |
Collapse
|
3
|
Amani A, Farajollahi AH. Drug Delivery Angle for Various Atherosclerosis and Aneurysm Percentages of the Carotid Artery. Mol Pharm 2024; 21:1777-1793. [PMID: 38478900 DOI: 10.1021/acs.molpharmaceut.3c01109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Stroke is the second cause of mortality among adult males and the first cause of death in adult females all around the world. It is also recognized as one of the most important causes of morbidity and dementia in adults. Stenosis or rupture of the only channels of the blood supply from the heart to the brain (carotid arteries) is among the main causes of stroke. In this regard, treatment of the lesions of carotid arteries, including atherosclerosis and aneurysm, could be a huge step in preventing stroke and improving brain performance. Targeted drug delivery by drug-carrying nanoparticles is the latest method for optimal delivery of drug to the damaged parts of the artery. In this study, a wide range of carotid artery lesions, including different percentages of atherosclerosis and aneurysm, were considered. After analyzing the dynamics of the fluid flow in different damaged regions and selecting the magnetic framework with proper ligand (Fe3O4@MOF) as the drug carrier, the size of the particles and their number per cycle were analyzed. Based on the results, the particle size of 100 nm and the use of 300 particles per injection at each cardiac cycle can result in maximum drug delivery to the target site. Then, the effect of the hospital bed angle on drug delivery was investigated. The results showed a unique optimal drug delivery angle for each extent of atherosclerosis or aneurysm. For example, in a 50% aneurysm, drug delivery at an angle of 30° is about 387% higher than that at an angle of 15°. Finally, simulation of real geometry indicated the effectiveness of simple geometry instead of real geometry for the simulation of carotid arteries, which can remarkably decrease the computational time and costs.
Collapse
Affiliation(s)
- Ali Amani
- School of Mechanical Engineering, Sharif University of Technology, Tehran 11155-9466, Iran
| | | |
Collapse
|
4
|
Bowers CA, Miller CT. Modeling flow of Carreau fluids in porous media. Phys Rev E 2023; 108:065106. [PMID: 38243484 DOI: 10.1103/physreve.108.065106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Accepted: 11/04/2023] [Indexed: 01/21/2024]
Abstract
Carreau fluids occur routinely in porous medium systems for a range of applications, and the dependence of the viscosity for such fluids on the rate of strain tensor poses challenges to modeling at an averaged macroscale. Traditional approaches for macroscale modeling such flows have relied upon experimental observations of flows for generalized Newtonian fluids (GNFs) and a phenomenological approach referred to herein as the shift factor. A recently developed approach based upon averaging conservation and thermodynamic equations from the microscale for Cross model GNFs is extended to the case of Carreau fluids and shown to predict the flow through both isotropic and anisotropic media accurately without the need for GNF-flow experiments. The model is formulated in terms of rheological properties, a standard Newtonian resistance tensor, and a length-scale tensor, which does require estimation. An approach based upon measures of the morphology and topology of the pore space is developed to approximate this length-scale tensor. Thus, this work provides the missing components needed to predict Carreau GNF macroscale flow with only rheological information for the fluid and analysis of the pore morphology and topology independent of any fluid flow experiments. Accuracy of predictions based upon this approach is quantified, and extension to other GNFs is straightforward.
Collapse
Affiliation(s)
- Christopher A Bowers
- Department of Environmental Sciences and Engineering, University of North Carolina at Chapel Hill, North Carolina 27599, USA
| | - Cass T Miller
- Department of Environmental Sciences and Engineering, University of North Carolina at Chapel Hill, North Carolina 27599, USA
| |
Collapse
|
5
|
Walsh D, Cunning C, Lee G, Boylan J, McLoughlin P. CAPILLARY LEAK AND EDEMA AFTER RESUSCITATION: THE POTENTIAL CONTRIBUTION OF REDUCED ENDOTHELIAL SHEAR STRESS CAUSED BY HEMODILUTION. Shock 2023; 60:487-495. [PMID: 37647080 DOI: 10.1097/shk.0000000000002215] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
ABSTRACT Normal shear stress is essential for the normal structure and functions of the microcirculation. Hemorrhagic shock leads to reduced shear stress due to reduced tissue perfusion. Although essential for the urgent restoration of cardiac output and systemic blood pressure, large volume resuscitation with currently available solutions causes hemodilution, further reducing endothelial shear stress. In this narrative review, we consider how the use of currently available resuscitation solutions results in persistent reduction in endothelial shear stress, despite successfully increasing cardiac output and systemic blood pressure. We consider how this reduced shear stress causes (1) a failure to restore normal vasomotor function and normal tissue perfusion thus leading to persistent tissue hypoxia and (2) increased microvascular endothelial permeability resulting in edema formation and impaired organ function. We discuss the need for clinical research into resuscitation strategies and solutions that aim to quickly restore endothelial shear stress in the microcirculation to normal.
Collapse
Affiliation(s)
| | - Ciara Cunning
- Department of Clinical Biochemistry, Mater Misericordiae University Hospital, Dublin, Ireland
| | | | | | - Paul McLoughlin
- School of Medicine and Conway Institute, University College Dublin, Dublin, Ireland
| |
Collapse
|
6
|
Bańka P, Wybraniec M, Bochenek T, Gruchlik B, Burchacka A, Swinarew A, Mizia-Stec K. Influence of Aortic Valve Stenosis and Wall Shear Stress on Platelets Function. J Clin Med 2023; 12:6301. [PMID: 37834945 PMCID: PMC10573628 DOI: 10.3390/jcm12196301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 09/19/2023] [Accepted: 09/26/2023] [Indexed: 10/15/2023] Open
Abstract
Aortic valve stenosis (AS) is a common heart valve disease in the elderly population, and its pathogenesis remains an interesting area of research. The degeneration of the aortic valve leaflets gradually progresses to valve sclerosis. The advanced phase is marked by the presence of extracellular fibrosis and calcification. Turbulent, accelerated blood flow generated by the stenotic valve causes excessive damage to the aortic wall. Elevated shear stress due to AS leads to the degradation of high-molecular weight multimers of von Willebrand factor, which may involve bleeding in the mucosal tissues. Conversely, elevated shear stress has been associated with the release of thrombin and the activation of platelets, even in individuals with acquired von Willebrand syndrome. Moreover, turbulent blood flow in the aorta may activate the endothelium and promote platelet adhesion and activation on the aortic valve surface. Platelets release a wide range of mediators, including lysophosphatidic acid, which have pro-osteogenic effects in AS. All of these interactions result in blood coagulation, fibrinolysis, and the hemostatic process. This review summarizes the current knowledge on high shear stress-induced hemostatic disorders, the influence of AS on platelets and antiplatelet therapy.
Collapse
Affiliation(s)
- Paweł Bańka
- First Department of Cardiology, School of Medicine in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
| | - Maciej Wybraniec
- First Department of Cardiology, School of Medicine in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
| | - Tomasz Bochenek
- First Department of Cardiology, School of Medicine in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
| | - Bartosz Gruchlik
- First Department of Cardiology, School of Medicine in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
| | - Aleksandra Burchacka
- First Department of Cardiology, School of Medicine in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
| | - Andrzej Swinarew
- Faculty of Science and Technology, University of Silesia in Katowice, 40-007 Katowice, Poland
- Department of Swimming and Water Rescue, Institute of Sport Science, The Jerzy Kukuczka Academy of Physical Education, 40-065 Katowice, Poland
| | - Katarzyna Mizia-Stec
- First Department of Cardiology, School of Medicine in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
| |
Collapse
|
7
|
Wei H, Amlani F, Pahlevan NM. Direct 0D-3D coupling of a lattice Boltzmann methodology for fluid-structure aortic flow simulations. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3683. [PMID: 36629353 DOI: 10.1002/cnm.3683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 11/29/2022] [Accepted: 01/06/2023] [Indexed: 05/05/2023]
Abstract
This work introduces a numerical approach and implementation for the direct coupling of arbitrary complex ordinary differential equation- (ODE-)governed zero-dimensional (0D) boundary conditions to three-dimensional (3D) lattice Boltzmann-based fluid-structure systems for hemodynamics studies. In particular, a most complex configuration is treated by considering a dynamic left ventricle- (LV-)elastance heart model which is governed by (and applied as) a nonlinear, non-stationary hybrid ODE-Dirichlet system. Other ODE-based boundary conditions, such as lumped parameter Windkessel models for truncated vasculature, are also considered. Performance studies of the complete 0D-3D solver, including its treatment of the lattice Boltzmann fluid equations and elastodynamics equations as well as their interactions, is conducted through a variety of benchmark and convergence studies that demonstrate the ability of the coupled 0D-3D methodology in generating physiological pressure and flow waveforms-ultimately enabling the exploration of various physical and physiological parameters for hemodynamics studies of the coupled LV-arterial system. The methods proposed in this paper can be easily applied to other ODE-based boundary conditions as well as to other fluid problems that are modeled by 3D lattice Boltzmann equations and that require direct coupling of dynamic 0D boundary conditions.
Collapse
Affiliation(s)
- Heng Wei
- Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, California, USA
| | - Faisal Amlani
- Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, California, USA
- Université Paris-Saclay, CentraleSupélec, ENS Paris-Saclay, CNRS, LMPS - Laboratoire de Mécanique Paris-Saclay, Gif-sur-Yvette, France
| | - Niema M Pahlevan
- Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, California, USA
- School of Medicine, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
8
|
Cheng H, Chen X, Zhong J, Li J, Qiu P, Wang K. Label-free measurement of wall shear stress in the brain venule and arteriole using dual-wavelength third-harmonic-generation line-scanning imaging. OPTICS LETTERS 2022; 47:5618-5621. [PMID: 37219285 DOI: 10.1364/ol.472136] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 10/06/2022] [Indexed: 05/24/2023]
Abstract
Wall shear stress (WSS) is of fundamental physiological and pathological significance. Current measurement technologies suffer from poor spatial resolution or cannot measure instantaneous values in a label-free manner. Here we demonstrate dual-wavelength third-harmonic-generation (THG) line-scanning imaging, for instantaneous wall shear rate and WSS measurement in vivo. We used the soliton self-frequency shift to generate dual-wavelength femtosecond pulses. Simultaneous acquisition of dual-wavelength THG line-scanning signals extract blood flow velocities at adjacent radial positions for instantaneous wall shear rate and WSS measurement. Our results show the oscillating behavior of WSS in brain venules and arterioles at micron spatial resolution in a label-free manner.
Collapse
|
9
|
Daniele A, Lucas SJE, Rendeiro C. Detrimental effects of physical inactivity on peripheral and brain vasculature in humans: Insights into mechanisms, long-term health consequences and protective strategies. Front Physiol 2022; 13:998380. [PMID: 36237532 PMCID: PMC9553009 DOI: 10.3389/fphys.2022.998380] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 08/25/2022] [Indexed: 11/13/2022] Open
Abstract
The growing prevalence of physical inactivity in the population highlights the urgent need for a more comprehensive understanding of how sedentary behaviour affects health, the mechanisms involved and what strategies are effective in counteracting its negative effects. Physical inactivity is an independent risk factor for different pathologies including atherosclerosis, hypertension and cardiovascular disease. It is known to progressively lead to reduced life expectancy and quality of life, and it is the fourth leading risk factor for mortality worldwide. Recent evidence indicates that uninterrupted prolonged sitting and short-term inactivity periods impair endothelial function (measured by flow-mediated dilation) and induce arterial structural alterations, predominantly in the lower body vasculature. Similar effects may occur in the cerebral vasculature, with recent evidence showing impairments in cerebral blood flow following prolonged sitting. The precise molecular and physiological mechanisms underlying inactivity-induced vascular dysfunction in humans are yet to be fully established, although evidence to date indicates that it may involve modulation of shear stress, inflammatory and vascular biomarkers. Despite the steady increase in sedentarism in our societies, only a few intervention strategies have been investigated for their efficacy in counteracting the associated vascular impairments. The current review provides a comprehensive overview of the evidence linking acute and short-term physical inactivity to detrimental effects on peripheral, central and cerebral vascular health in humans. We further examine the underlying molecular and physiological mechanisms and attempt to link these to long-term consequences for cardiovascular health. Finally, we summarize and discuss the efficacy of lifestyle interventions in offsetting the negative consequences of physical inactivity.
Collapse
Affiliation(s)
- Alessio Daniele
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Samuel J. E. Lucas
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom
- Centre for Human Brain Health, University of Birmingham, Birmingham, United Kingdom
| | - Catarina Rendeiro
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom
- Centre for Human Brain Health, University of Birmingham, Birmingham, United Kingdom
- *Correspondence: Catarina Rendeiro,
| |
Collapse
|
10
|
Giannokostas K, Dimakopoulos Y, Tsamopoulos J. Shear stress and intravascular pressure effects on vascular dynamics: two-phase blood flow in elastic microvessels accounting for the passive stresses. Biomech Model Mechanobiol 2022; 21:1659-1684. [PMID: 35962247 DOI: 10.1007/s10237-022-01612-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 07/07/2022] [Indexed: 11/02/2022]
Abstract
We study the steady hemodynamics in physiological elastic microvessels proposing an advanced fluid-structure interaction model. The arteriolar tissue is modeled as a two-layer fiber-reinforced hyperelastic material representing its Media and Adventitia layers. The constitutive model employed (Holzapfel et al. in J Elast 61:1-48, 2000) is parametrized via available data on stress-strain experiments for arterioles. The model is completed by simulating the blood/plasma flow in the lumen, using the thixotropic elasto-viscoplastic model in its core, and the linear Phan-Thien and Tanner viscoelastic model in its annular part. The Cell-Free Layer (CFL) and the Fåhraeus and Fåhraeus-Lindqvist effects are considered via analytical expressions based on experimental data (Giannokostas et al. in Materials (Basel) 14:367, 2021b). The coupling between tissue deformation and blood flow is achieved through the experimentally verified pressure-shear hypothesis (Pries et al. Circ Res 77:1017-1023, 1995). Our calculations confirm that the increase in the reference inner radius produces larger expansion. Also, by increasing the intraluminal pressure, the thinning of the walls is more pronounced and it may reach 40% of the initial thickness. Comparing our predictions with those in rigid-wall microtubes, we conclude that apart from the vital importance of vasodilation, there is an up to 25% reduction in wall shear stress. The passive vasodilation contributes to the decrease in the tissue stress fields and affects the hemodynamic features such as the CFL thickness, reducing the plasma layer when blood flows in vessels with elastic walls, in quantitative agreement with previous experiments. Our calculations verify the correctness of the pressure-shear hypothesis but not that of the Laplace law.
Collapse
Affiliation(s)
- K Giannokostas
- Laboratory of Fluid Mechanics and Rheology, Department of Chemical Engineering, University of Patras, Patras, Greece
| | - Y Dimakopoulos
- Laboratory of Fluid Mechanics and Rheology, Department of Chemical Engineering, University of Patras, Patras, Greece.
| | - J Tsamopoulos
- Laboratory of Fluid Mechanics and Rheology, Department of Chemical Engineering, University of Patras, Patras, Greece
| |
Collapse
|
11
|
Saeed Khan MW, Ali N, Bég OA. Thermal entrance problem for blood flow inside an axisymmetric tube: The classical Graetz problem extended for Quemada’s bio-rheological fluid with axial conduction. Proc Inst Mech Eng H 2022; 236:848-859. [DOI: 10.1177/09544119221086479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The heat-conducting nature of blood is critical in the human circulatory system and features also in important thermal regulation and blood processing systems in biomedicine. Motivated by these applications, in the present investigation, the classical Graetz problem in heat transfer is extended to the case of a bio-rheological fluid model. The Quemada bio-rheological fluid model is selected since it has been shown to be accurate in mimicking physiological flows (blood) at different shear rates and hematocrits. The steady two-dimensional energy equation without viscous dissipation in stationary regime is tackled via a separation of variables approach for the isothermal wall temperature case. Following the introduction of transformation variables, the ensuing dimensionless boundary value problem is solved numerically via MATLAB based algorithm known as bvp5c (a finite difference code that implements the four-stage Lobatto IIIa collocation formula). Numerical validation is also presented against two analytical approaches namely, series solutions and Kummer function techniques. Axial conduction in terms of Péclet number is also considered. Typical values of Reynolds number and Prandtl number are used to categorize the vascular regions. The graphical representation of mean temperature, temperature gradient, and Nusselt numbers along with detail discussions are presented for the effects of Quemada non-Newtonian parameters and Péclet number. The current analysis may also have potential applications for the development of microfluidic and biofluidic devices particularly which are used in the diagnosis of diseases in addition to blood oxygenation technologies.
Collapse
Affiliation(s)
| | - Nasir Ali
- Department of Mathematics and Statistics, International Islamic University, Islamabad, Pakistan
| | - O Anwar Bég
- Multiphysical Engineering Sciences, Aeronautical and Mechanical Engineering Department, Salford University, Salford, UK
| |
Collapse
|
12
|
van Batenburg-Sherwood J, Balabani S. Continuum microhaemodynamics modelling using inverse rheology. Biomech Model Mechanobiol 2022; 21:335-361. [PMID: 34907491 PMCID: PMC8807439 DOI: 10.1007/s10237-021-01537-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 11/23/2021] [Indexed: 11/03/2022]
Abstract
Modelling blood flow in microvascular networks is challenging due to the complex nature of haemorheology. Zero- and one-dimensional approaches cannot reproduce local haemodynamics, and models that consider individual red blood cells (RBCs) are prohibitively computationally expensive. Continuum approaches could provide an efficient solution, but dependence on a large parameter space and scarcity of experimental data for validation has limited their application. We describe a method to assimilate experimental RBC velocity and concentration data into a continuum numerical modelling framework. Imaging data of RBCs were acquired in a sequentially bifurcating microchannel for various flow conditions. RBC concentration distributions were evaluated and mapped into computational fluid dynamics simulations with rheology prescribed by the Quemada model. Predicted velocities were compared to particle image velocimetry data. A subset of cases was used for parameter optimisation, and the resulting model was applied to a wider data set to evaluate model efficacy. The pre-optimised model reduced errors in predicted velocity by 60% compared to assuming a Newtonian fluid, and optimisation further reduced errors by 40%. Asymmetry of RBC velocity and concentration profiles was demonstrated to play a critical role. Excluding asymmetry in the RBC concentration doubled the error, but excluding spatial distributions of shear rate had little effect. This study demonstrates that a continuum model with optimised rheological parameters can reproduce measured velocity if RBC concentration distributions are known a priori. Developing this approach for RBC transport with more network configurations has the potential to provide an efficient approach for modelling network-scale haemodynamics.
Collapse
Affiliation(s)
| | - Stavroula Balabani
- Department of Mechanical Engineering, University College London, London, UK
| |
Collapse
|
13
|
High Output Heart Failure in Multiple Myeloma: Pathogenetic Considerations. Cancers (Basel) 2022; 14:cancers14030610. [PMID: 35158878 PMCID: PMC8833382 DOI: 10.3390/cancers14030610] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 01/19/2022] [Accepted: 01/21/2022] [Indexed: 02/01/2023] Open
Abstract
Simple Summary Multiple myeloma is a plasma cell disorder that accounts for around 10% of all haematological malignancies. This neoplasia is often associated with a significant prevalence of cardiovascular complications resulting from several factors, unrelated and/or related to the disease. Among cardiovascular complications, the high output heart failure is of great importance as it is related to a worse prognosis for patients. It is important to point out that, despite the availability of more and more numerous and effective drugs, myeloma remains an incurable disease, with frequent relapses and several treatment lines, with the need, therefore, for a careful evaluation of patients, especially from a cardiological point of view. For this reason, we are proposing a comprehensive overview of different pathogenetic mechanisms responsible for high output heart failure in multiple myeloma, including artero-venous shunts, enhanced angiogenesis, glutamminolysis, hyperammonemia and hemorheological alterations, with the belief that a multidisciplinary approach, in clinical evaluation is critical for the optimal management of the patient. Abstract The high output heart failure is a clinical condition in which the systemic congestion is associated to a high output state, and it can be observed in a non-negligible percentage of hematological diseases, particularly in multiple myeloma, a condition in which the risk of adverse cardiovascular events may increase, with a worse prognosis for patients. For this reason, though an accurate literature search, we provided in this review a complete overview of different pathogenetic mechanisms responsible for high output heart failure in multiple myeloma. Indeed, this clinical finding is present in the 8% of multiple myeloma patients, and it may be caused by artero-venous shunts, enhanced angiogenesis, glutamminolysis, hyperammonemia and hemorheological alterations with increase in plasma viscosity. The high output heart failure in multiple myeloma is associated with significant morbidity and mortality, emphasizing the need for a multidisciplinary approach.
Collapse
|
14
|
Sunderland K, Jiang J, Zhao F. Disturbed flow's impact on cellular changes indicative of vascular aneurysm initiation, expansion, and rupture: A pathological and methodological review. J Cell Physiol 2022; 237:278-300. [PMID: 34486114 PMCID: PMC8810685 DOI: 10.1002/jcp.30569] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 08/06/2021] [Accepted: 08/16/2021] [Indexed: 01/03/2023]
Abstract
Aneurysms are malformations within the arterial vasculature brought on by the structural breakdown of the microarchitecture of the vessel wall, with aneurysms posing serious health risks in the event of their rupture. Blood flow within vessels is generally laminar with high, unidirectional wall shear stressors that modulate vascular endothelial cell functionality and regulate vascular smooth muscle cells. However, altered vascular geometry induced by bifurcations, significant curvature, stenosis, or clinical interventions can alter the flow, generating low stressor disturbed flow patterns. Disturbed flow is associated with altered cellular morphology, upregulated expression of proteins modulating inflammation, decreased regulation of vascular permeability, degraded extracellular matrix, and heightened cellular apoptosis. The understanding of the effects disturbed flow has on the cellular cascades which initiate aneurysms and promote their subsequent growth can further elucidate the nature of this complex pathology. This review summarizes the current knowledge about the disturbed flow and its relation to aneurysm pathology, the methods used to investigate these relations, as well as how such knowledge has impacted clinical treatment methodologies. This information can contribute to the understanding of the development, growth, and rupture of aneurysms and help develop novel research and aneurysmal treatment techniques.
Collapse
Affiliation(s)
- Kevin Sunderland
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931
| | - Jingfeng Jiang
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931,Corresponding Authors: Feng Zhao, 101 Bizzell Street, College Station, TX 77843-312, Tel : 979-458-1239, , Jingfeng Jiang, 1400 Townsend Dr., Houghton, MI 49931, Tel: 906-487-1943
| | - Feng Zhao
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843,Corresponding Authors: Feng Zhao, 101 Bizzell Street, College Station, TX 77843-312, Tel : 979-458-1239, , Jingfeng Jiang, 1400 Townsend Dr., Houghton, MI 49931, Tel: 906-487-1943
| |
Collapse
|
15
|
Li W, Tsai AG, Intaglietta M, Tartakovsky DM. A model of anemic tissue perfusion after blood transfusion shows critical role of endothelial response to shear stress stimuli. J Appl Physiol (1985) 2021; 131:1815-1823. [PMID: 34647829 DOI: 10.1152/japplphysiol.00524.2021] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Although some of the cardiovascular responses to changes in hematocrit (Hct) are not fully quantified experimentally, available information is sufficient to build a mathematical model of the consequences of treating anemia by introducing RBCs into the circulation via blood transfusion. We present such a model, which describes how the treatment of normovolemic anemia with blood transfusion impacts oxygen (O2) delivery (DO2, the product of blood O2 content and arterial blood flow) by the microcirculation. Our analysis accounts for the differential response of the endothelium to the wall shear stress (WSS) stimulus, changes in nitric oxide (NO) production due to modification of blood viscosity caused by alterations of both hematocrit (Hct) and cell free layer thickness, as well as for their combined effects on microvascular blood flow and DO2. Our model shows that transfusions of 1- and 2-unit of blood have a minimal effect on DO2 if the microcirculation is unresponsive to the WSS stimulus for NO production that causes vasodilatation increasing blood flow and DO2. Conversely, in a fully WSS responsive organism, blood transfusion significantly enhances blood flow and DO2, because increased viscosity stimulates endothelial NO production causing vasodilatation. This finding suggests that evaluation of a patients' pretransfusion endothelial WSS responsiveness should be beneficial in determining the optimal transfusion requirements for treating patients with anemia.NEW & NOTEWORTHY Transfusion of 1 or 2 units of blood accounts for about 3/4 of the world blood consumption of 119 million units per year, whereas a current world demand deficit is on the order of 100 million units. Therefore, factors supporting the practice of transfusing 1 unit instead of 2 are of interest, given their potential to expand the number of interventions without increasing blood availability. Our mathematical model provides a physiological support for this practice.
Collapse
Affiliation(s)
- Weiyu Li
- Department of Energy Resources Engineering, Stanford University, Stanford, California
| | - Amy G Tsai
- Department of Bioengineering, University of California, San Diego, California
| | - Marcos Intaglietta
- Department of Bioengineering, University of California, San Diego, California
| | - Daniel M Tartakovsky
- Department of Energy Resources Engineering, Stanford University, Stanford, California
| |
Collapse
|
16
|
Abstract
Single-fluid-phase porous medium systems are typically modeled at an averaged length scale termed the macroscale, and Darcy's law is typically relied upon as an approximation of the momentum equation under Stokes flow conditions. Standard approaches for modeling macroscale single-fluid-phase flow of generalized Newtonian fluids (GNFs) extend the standard Newtonian model based upon Darcy's law using an effective viscosity and assuming that the intrinsic permeability is invariant with respect to fluid properties. This approach results in a need to perform an experiment for a non-Newtonian fluid, the introduction of effective parameters that are not tied to known microscale physics, and uncertainty regarding the dependencies of the fitted empirical parameter on system properties. We use the thermodynamically constrained averaging theory (TCAT) to examine the formulation and closure of a macroscale model for GNF flow that is consistent with microscale conservation principles and the second law of thermodynamics. A direct connection between microscale and macroscale quantities is used to formulate an expression for interphase momentum transfer for GNF flow in porous medium systems. Darcy's law is shown to approximate momentum transfer from the fluid phase to the solid phase. Momentum transfer is found to depend on the viscosity at the solid surface, which is only invariant for Newtonian flow. TCAT is used to derive a macroscale equation for the hydraulic resistance based on accessible fluid and solid properties. This hydraulic resistance may be used in the same way that hydraulic conductivity is typically used to model flow at the macroscale, and it includes parameters that can be calculated a priori, without the need to carry out microscale simulations, or experiments, for any GNF. The TCAT approach is validated for four model isotropic and anisotropic media and five Cross-model fluids. The traditional shift factor and effective viscosity are related to the newly derived TCAT model, shedding new light on this common empirical approach. The results from this work form a basis for the modeling of GNF flow in porous medium systems under Stokes flow, which is predictive given the rheological properties of the GNF and the resistance observed for Newtonian flow.
Collapse
|
17
|
Tran HDN, Moonshi SS, Xu ZP, Ta HT. Influence of nanoparticles on the haemostatic balance: between thrombosis and haemorrhage. Biomater Sci 2021; 10:10-50. [PMID: 34775503 DOI: 10.1039/d1bm01351c] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Maintenance of a delicate haemostatic balance or a balance between clotting and bleeding is critical to human health. Irrespective of administration route, nanoparticles can reach the bloodstream and might interrupt the haemostatic balance by interfering with one or more components of the coagulation, anticoagulation, and fibrinolytic systems, which potentially lead to thrombosis or haemorrhage. However, inadequate understanding of their effects on the haemostatic balance, along with the fact that most studies mainly focus on the functionality of nanoparticles while forgetting or leaving behind their risk to the body's haemostatic balance, is a major concern. Hence, our review aims to provide a comprehensive depiction of nanoparticle-haemostatic balance interactions, which has not yet been covered. The synergistic roles of cells and plasma factors participating in haemostatic balance are presented. Possible interactions and interference of each type of nanoparticle with the haemostatic balance are comprehensively discussed, particularly focusing on the underlying mechanisms. Interactions of nanoparticles with innate immunity potentially linked to haemostasis are mentioned. Various physicochemical characteristics that influence the nanoparticle-haemostatic balance are detailed. Challenges and future directions are also proposed. This insight would be valuable for the establishment of nanoparticles that can either avoid unintended interference with the haemostatic balance or purposely downregulate/upregulate its key components in a controlled manner.
Collapse
Affiliation(s)
- Huong D N Tran
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland 4111, Australia. .,Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland 4072, Australia
| | | | - Zhi Ping Xu
- Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland 4072, Australia
| | - Hang Thu Ta
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland 4111, Australia. .,Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland 4072, Australia.,School of Environment and Science, Griffith University, Nathan, Queensland 4111, Australia
| |
Collapse
|
18
|
Liu H, Lan L, Abrigo J, Ip HL, Soo Y, Zheng D, Wong KS, Wang D, Shi L, Leung TW, Leng X. Comparison of Newtonian and Non-newtonian Fluid Models in Blood Flow Simulation in Patients With Intracranial Arterial Stenosis. Front Physiol 2021; 12:718540. [PMID: 34552505 PMCID: PMC8450390 DOI: 10.3389/fphys.2021.718540] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Accepted: 08/16/2021] [Indexed: 11/22/2022] Open
Abstract
Background Newtonian fluid model has been commonly applied in simulating cerebral blood flow in intracranial atherosclerotic stenosis (ICAS) cases using computational fluid dynamics (CFD) modeling, while blood is a shear-thinning non-Newtonian fluid. We aimed to investigate the differences of cerebral hemodynamic metrics quantified in CFD models built with Newtonian and non-Newtonian fluid assumptions, in patients with ICAS. Methods We built a virtual artery model with an eccentric 75% stenosis and performed static CFD simulation. We also constructed CFD models in three patients with ICAS of different severities in the luminal stenosis. We performed static simulations on these models with Newtonian and two non-Newtonian (Casson and Carreau-Yasuda) fluid models. We also performed transient simulations on another patient-specific model. We measured translesional pressure ratio (PR) and wall shear stress (WSS) values in all CFD models, to reflect the changes in pressure and WSS across a stenotic lesion. In all the simulations, we compared the PR and WSS values in CFD models derived with Newtonian, Casson, and Carreau-Yasuda fluid assumptions. Results In all the static and transient simulations, the Newtonian/non-Newtonian difference on PR value was negligible. As to WSS, in static models (virtual and patient-specific), the rheological difference was not obvious in areas with high WSS, but observable in low WSS areas. In the transient model, the rheological difference of WSS areas with low WSS was enhanced, especially during diastolic period. Conclusion Newtonian fluid model could be applicable for PR calculation, but caution needs to be taken when using the Newtonian assumption in simulating WSS especially in severe ICAS cases.
Collapse
Affiliation(s)
- Haipeng Liu
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China.,Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong, China.,Research Centre for Intelligent Healthcare, Coventry University, Coventry, United Kingdom
| | - Linfang Lan
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China
| | - Jill Abrigo
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong, China
| | - Hing Lung Ip
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China
| | - Yannie Soo
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China
| | - Dingchang Zheng
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, United Kingdom
| | - Ka Sing Wong
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China
| | - Defeng Wang
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong, China
| | - Lin Shi
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong, China
| | - Thomas W Leung
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China
| | - Xinyi Leng
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China
| |
Collapse
|
19
|
Stephanou PS. Elucidating the rheological implications of adding particles in blood. RHEOLOGICA ACTA 2021; 60:603-616. [PMID: 34334825 PMCID: PMC8313244 DOI: 10.1007/s00397-021-01289-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 06/29/2021] [Accepted: 06/30/2021] [Indexed: 06/13/2023]
Abstract
UNLABELLED In the past few decades, nanotechnology has been employed to provide breakthroughs in the diagnosis and treatment of several diseases using drug-carrying particles (DCPs). In such an endeavor, the optimal design of DCPs is paramount, which necessitates the use of an accurate and trustworthy constitutive model in computational fluid dynamics (CFD) simulators. We herein introduce a continuum model for elaborating on the rheological implications of adding particles in blood. The model is developed using non-equilibrium thermodynamics to guarantee thermodynamic admissibility. Red blood cells are modeled as deformed droplets with a constant volume that are able to aggregate, whereas particles are considered rigid spheroids. The model predictions are compared favorably against rheological data for both spherical and non-spherical particles immersed in non-aggregating blood. It is expected that the use of this model will allow for the testing of DCPs in virtual patients and for their tailor-design in treating various diseases. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s00397-021-01289-x.
Collapse
Affiliation(s)
- Pavlos S. Stephanou
- Department of Chemical Engineering, Cyprus University of Technology, PO Box 50329, 3603 Limassol, Cyprus
| |
Collapse
|
20
|
Dessalles CA, Leclech C, Castagnino A, Barakat AI. Integration of substrate- and flow-derived stresses in endothelial cell mechanobiology. Commun Biol 2021; 4:764. [PMID: 34155305 PMCID: PMC8217569 DOI: 10.1038/s42003-021-02285-w] [Citation(s) in RCA: 77] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Accepted: 06/02/2021] [Indexed: 02/05/2023] Open
Abstract
Endothelial cells (ECs) lining all blood vessels are subjected to large mechanical stresses that regulate their structure and function in health and disease. Here, we review EC responses to substrate-derived biophysical cues, namely topography, curvature, and stiffness, as well as to flow-derived stresses, notably shear stress, pressure, and tensile stresses. Because these mechanical cues in vivo are coupled and are exerted simultaneously on ECs, we also review the effects of multiple cues and describe burgeoning in vitro approaches for elucidating how ECs integrate and interpret various mechanical stimuli. We conclude by highlighting key open questions and upcoming challenges in the field of EC mechanobiology.
Collapse
Affiliation(s)
- Claire A Dessalles
- LadHyX, CNRS, Ecole polytechnique, Institut polytechnique de Paris, Palaiseau, France
| | - Claire Leclech
- LadHyX, CNRS, Ecole polytechnique, Institut polytechnique de Paris, Palaiseau, France
| | - Alessia Castagnino
- LadHyX, CNRS, Ecole polytechnique, Institut polytechnique de Paris, Palaiseau, France
| | - Abdul I Barakat
- LadHyX, CNRS, Ecole polytechnique, Institut polytechnique de Paris, Palaiseau, France.
| |
Collapse
|
21
|
Kanda H, Yamakuchi M, Matsumoto K, Mukaihara K, Shigehisa Y, Tachioka S, Okawa M, Takenouchi K, Oyama Y, Hashiguchi T, Imoto Y. Dynamic changes in platelets caused by shear stress in aortic valve stenosis. Clin Hemorheol Microcirc 2021; 77:71-81. [PMID: 32924997 PMCID: PMC7990459 DOI: 10.3233/ch-200928] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
BACKGROUND AND OBJECTIVE: Turbulent blood flow in patients with aortic valve stenosis (AS) results in morphological and functional changes in platelets and coagulation factors. The aim of this study is to determine how shear stress affects platelets and coagulation factors. METHODS: We retrospectively evaluated data from 78 patients who underwent AVR to treat AS between March 2008 and July 2017 at Kagoshima University Hospital. RESULTS: Platelet (PLT) count obviously decreased at three days after AVR, and increased above preoperative levels at the time of discharge. In contrast, platelet distribution width (PDW), mean platelet volume (MPV), and platelet large cell ratio (P-LCR) increased three days after AVR, then decreased to below preoperative levels. No differences were evident between groups with higher (HPPG > 100 mmHg) and lower (LPPG < 100 mmHg) peak pressure gradients (PPG) before AVR, whereas PLT count, PDW, MPV and P-LCR improved more in the HPPG group. Plateletcrit (PCT), which represents the total volume of platelets, increased after AVR due to decreased shear stress. High increasing rate of PCT was associated with lower PLT count, higher PDW and lower fibrinogen. CONCLUSION: Shear stress affects PLT count, PDW, and fibrinogen in patients with AS.
Collapse
Affiliation(s)
- Hideaki Kanda
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Munekazu Yamakuchi
- Department of Laboratory and Vascular Medicine, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Kazuhisa Matsumoto
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Kosuke Mukaihara
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Yoshiya Shigehisa
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Shuji Tachioka
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Masashi Okawa
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Kazunori Takenouchi
- Department of Laboratory and Vascular Medicine, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Yoko Oyama
- Department of Laboratory and Vascular Medicine, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Teruto Hashiguchi
- Department of Laboratory and Vascular Medicine, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Yutaka Imoto
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| |
Collapse
|
22
|
Riva A, Sturla F, Caimi A, Pica S, Giese D, Milani P, Palladini G, Lombardi M, Redaelli A, Votta E. 4D flow evaluation of blood non-Newtonian behavior in left ventricle flow analysis. J Biomech 2021; 119:110308. [PMID: 33631666 DOI: 10.1016/j.jbiomech.2021.110308] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 02/03/2021] [Indexed: 12/31/2022]
Abstract
Blood is generally modeled as a Newtonian fluid, assuming a standard and constant viscosity; however, this assumption may not hold for the highly pulsatile and recirculating intracavitary flow in the left ventricle (LV), hampering the quantification of fluid dynamic indices of potential clinical relevance. Herein, we investigated the effect of three viscosity models on the patient-specific quantification of LV blood energetics, namely on viscous energy loss (EL), from 4D Flow magnetic resonance imaging: I) Newtonian with standard viscosity (3.7 cP), II) Newtonian with subject-specific hematocrit-dependent viscosity, III) non-Newtonian accounting for the effect of hematocrit and shear rate. Analyses were performed on 5 controls and 5 patients with cardiac light-chain amyloidosis. In Model II, viscosity ranged between 3.0 (-19%) and 4.3 cP (+16%), mildly deviating from the standard value. In the non-Newtonian model, this effect was emphasized: viscosity ranged from 3.2 to 6.0 cP, deviating maximally from the standard value in low shear rate (i.e., <100 s-1) regions. This effect reflected on EL quantifications: in particular, as compared to Model I, Model III yielded markedly higher EL values (up to +40%) or markedly lower (down to -21%) for subjects with hematocrit higher than 39.5% and lower than 30%, respectively. Accounting for non-Newtonian blood behavior on a patient-specific basis may enhance the accuracy of intracardiac energetics assessment by 4D Flow, which may be explored as non-invasive index to discriminate between healthy and pathologic LV.
Collapse
Affiliation(s)
- Alessandra Riva
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy; 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Francesco Sturla
- 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy; Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
| | - Alessandro Caimi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Silvia Pica
- Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | | | - Paolo Milani
- Amyloidosis Research and Treatment Center, Fondazione IRCCS Policlinico San Matteo and University of Pavia, Pavia, Italy
| | - Giovanni Palladini
- Amyloidosis Research and Treatment Center, Fondazione IRCCS Policlinico San Matteo and University of Pavia, Pavia, Italy
| | - Massimo Lombardi
- Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Emiliano Votta
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy; 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| |
Collapse
|
23
|
Giannokostas K, Dimakopoulos Y, Anayiotos A, Tsamopoulos J. Advanced Constitutive Modeling of the Thixotropic Elasto-Visco-Plastic Behavior of Blood: Steady-State Blood Flow in Microtubes. MATERIALS (BASEL, SWITZERLAND) 2021; 14:E367. [PMID: 33451107 PMCID: PMC7828603 DOI: 10.3390/ma14020367] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 01/02/2021] [Accepted: 01/09/2021] [Indexed: 12/15/2022]
Abstract
The present work focuses on the in-silico investigation of the steady-state blood flow in straight microtubes, incorporating advanced constitutive modeling for human blood and blood plasma. The blood constitutive model accounts for the interplay between thixotropy and elasto-visco-plasticity via a scalar variable that describes the level of the local blood structure at any instance. The constitutive model is enhanced by the non-Newtonian modeling of the plasma phase, which features bulk viscoelasticity. Incorporating microcirculation phenomena such as the cell-free layer (CFL) formation or the Fåhraeus and the Fåhraeus-Lindqvist effects is an indispensable part of the blood flow investigation. The coupling between them and the momentum balance is achieved through correlations based on experimental observations. Notably, we propose a new simplified form for the dependence of the apparent viscosity on the hematocrit that predicts the CFL thickness correctly. Our investigation focuses on the impact of the microtube diameter and the pressure-gradient on velocity profiles, normal and shear viscoelastic stresses, and thixotropic properties. We demonstrate the microstructural configuration of blood in steady-state conditions, revealing that blood is highly aggregated in narrow tubes, promoting a flat velocity profile. Additionally, the proper accounting of the CFL thickness shows that for narrow microtubes, the reduction of discharged hematocrit is significant, which in some cases is up to 70%. At high pressure-gradients, the plasmatic proteins in both regions are extended in the flow direction, developing large axial normal stresses, which are more significant in the core region. We also provide normal stress predictions at both the blood/plasma interface (INS) and the tube wall (WNS), which are difficult to measure experimentally. Both decrease with the tube radius; however, they exhibit significant differences in magnitude and type of variation. INS varies linearly from 4.5 to 2 Pa, while WNS exhibits an exponential decrease taking values from 50 mPa to zero.
Collapse
Affiliation(s)
- Konstantinos Giannokostas
- Laboratory of Fluid Mechanics and Rheology, Department of Chemical Engineering, University of Patras, 26504 Patras, Greece; (K.G.); (J.T.)
| | - Yannis Dimakopoulos
- Laboratory of Fluid Mechanics and Rheology, Department of Chemical Engineering, University of Patras, 26504 Patras, Greece; (K.G.); (J.T.)
| | - Andreas Anayiotos
- Department of Mechanical and Materials Engineering, Cyprus University of Technology, Limassol 3036, Cyprus;
| | - John Tsamopoulos
- Laboratory of Fluid Mechanics and Rheology, Department of Chemical Engineering, University of Patras, 26504 Patras, Greece; (K.G.); (J.T.)
| |
Collapse
|
24
|
Rubio JE, Skotak M, Alay E, Sundaramurthy A, Subramaniam DR, Kote VB, Yeoh S, Monson K, Chandra N, Unnikrishnan G, Reifman J. Does Blast Exposure to the Torso Cause a Blood Surge to the Brain? Front Bioeng Biotechnol 2020; 8:573647. [PMID: 33392161 PMCID: PMC7773947 DOI: 10.3389/fbioe.2020.573647] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 11/16/2020] [Indexed: 02/04/2023] Open
Abstract
The interaction of explosion-induced blast waves with the torso is suspected to contribute to brain injury. In this indirect mechanism, the wave-torso interaction is assumed to generate a blood surge, which ultimately reaches and damages the brain. However, this hypothesis has not been comprehensively and systematically investigated, and the potential role, if any, of the indirect mechanism in causing brain injury remains unclear. In this interdisciplinary study, we performed experiments and developed mathematical models to address this knowledge gap. First, we conducted blast-wave exposures of Sprague-Dawley rats in a shock tube at incident overpressures of 70 and 130 kPa, where we measured carotid-artery and brain pressures while limiting exposure to the torso. Then, we developed three-dimensional (3-D) fluid-structure interaction (FSI) models of the neck and cerebral vasculature and, using the measured carotid-artery pressures, performed simulations to predict mass flow rates and wall shear stresses in the cerebral vasculature. Finally, we developed a 3-D finite element (FE) model of the brain and used the FSI-computed vasculature pressures to drive the FE model to quantify the blast-exposure effects in the brain tissue. The measurements from the torso-only exposure experiments revealed marginal increases in the peak carotid-artery overpressures (from 13.1 to 28.9 kPa). Yet, relative to the blast-free, normotensive condition, the FSI simulations for the blast exposures predicted increases in the peak mass flow rate of up to 255% at the base of the brain and increases in the wall shear stress of up to 289% on the cerebral vasculature. In contrast, our simulations suggest that the effect of the indirect mechanism on the brain-tissue-strain response is negligible (<1%). In summary, our analyses show that the indirect mechanism causes a sudden and abundant stream of blood to rapidly propagate from the torso through the neck to the cerebral vasculature. This blood surge causes a considerable increase in the wall shear stresses in the brain vasculature network, which may lead to functional and structural effects on the cerebral veins and arteries, ultimately leading to vascular pathology. In contrast, our findings do not support the notion of strain-induced brain-tissue damage due to the indirect mechanism.
Collapse
Affiliation(s)
- Jose E Rubio
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States.,The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, United States
| | - Maciej Skotak
- Department of Biomedical Engineering, Center for Injury Biomechanics, Materials, and Medicine, New Jersey Institute of Technology, Newark, NJ, United States.,Blast Induced Neurotrauma Division, Walter Reed Army Institute of Research, Silver Spring, MD, United States
| | - Eren Alay
- Department of Biomedical Engineering, Center for Injury Biomechanics, Materials, and Medicine, New Jersey Institute of Technology, Newark, NJ, United States
| | - Aravind Sundaramurthy
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States.,The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, United States
| | - Dhananjay Radhakrishnan Subramaniam
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States.,The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, United States
| | - Vivek Bhaskar Kote
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States.,The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, United States
| | - Stewart Yeoh
- Department of Biomedical Engineering, College of Engineering, The University of Utah, Salt Lake City, UT, United States
| | - Kenneth Monson
- Department of Biomedical Engineering, College of Engineering, The University of Utah, Salt Lake City, UT, United States.,Department of Mechanical Engineering, College of Engineering, The University of Utah, Salt Lake City, UT, United States
| | - Namas Chandra
- Department of Biomedical Engineering, Center for Injury Biomechanics, Materials, and Medicine, New Jersey Institute of Technology, Newark, NJ, United States
| | - Ginu Unnikrishnan
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States.,The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, United States
| | - Jaques Reifman
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States
| |
Collapse
|
25
|
Bray MA, Sartain SE, Gollamudi J, Rumbaut RE. Microvascular thrombosis: experimental and clinical implications. Transl Res 2020; 225:105-130. [PMID: 32454092 PMCID: PMC7245314 DOI: 10.1016/j.trsl.2020.05.006] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 05/12/2020] [Accepted: 05/17/2020] [Indexed: 02/07/2023]
Abstract
A significant amount of clinical and research interest in thrombosis is focused on large vessels (eg, stroke, myocardial infarction, deep venous thrombosis, etc.); however, thrombosis is often present in the microcirculation in a variety of significant human diseases, such as disseminated intravascular coagulation, thrombotic microangiopathy, sickle cell disease, and others. Further, microvascular thrombosis has recently been demonstrated in patients with COVID-19, and has been proposed to mediate the pathogenesis of organ injury in this disease. In many of these conditions, microvascular thrombosis is accompanied by inflammation, an association referred to as thromboinflammation. In this review, we discuss endogenous regulatory mechanisms that prevent thrombosis in the microcirculation, experimental approaches to induce microvascular thrombi, and clinical conditions associated with microvascular thrombosis. A greater understanding of the links between inflammation and thrombosis in the microcirculation is anticipated to provide optimal therapeutic targets for patients with diseases accompanied by microvascular thrombosis.
Collapse
Key Words
- adamts13, a disintegrin-like and metalloproteinase with thrombospondin type 1 motif 13
- ap, alternate pathway
- apc, activated protein c
- aps, antiphospholipid syndrome
- caps, catastrophic aps
- asfa, american society for apheresis
- atp, adenosine triphosphate
- cfh, complement factor h
- con a, concavalin a
- cox, cyclooxygenase
- damp, damage-associated molecular pattern
- dic, disseminated intravascular coagulation
- gbm, glomerular basement membrane
- hellp, hemolysis, elevated liver enzymes, low platelets
- hitt, heparin-induced thrombocytopenia and thrombosis
- hlh, hemophagocytic lymphohistiocytosis
- hus, hemolytic-uremic syndrome
- isth, international society for thrombosis and haemostasis
- ivig, intravenous immunoglobulin
- ldh, lactate nos, nitric oxide synthase
- net, neutrophil extracellular trap
- pai-1, plasminogen activator inhibitor 1
- pf4, platelet factor 4
- prr, pattern recognition receptor
- rbc, red blood cell
- scd, sickle cell disease
- sle, systemic lupus erythematosus
- tlr, toll-like receptor
- tf, tissue factor
- tfpi, tissue factor pathway inhibitor
- tma, thrombotic microangiopathy
- tnf-α, tumor necrosis factor-α
- tpe, therapeutic plasma exchange
- ulc, ultra large heparin-pf4 complexes
- ulvwf, ultra-large von willebrand factor
- vwf, von willebrand factor
Collapse
Affiliation(s)
- Monica A Bray
- Center for Translational Research on Inflammatory Diseases (CTRID), Michael E. DeBakey VA Medical Center, Houston, Texas; Baylor College of Medicine, Houston, Texas
| | - Sarah E Sartain
- Center for Translational Research on Inflammatory Diseases (CTRID), Michael E. DeBakey VA Medical Center, Houston, Texas; Baylor College of Medicine, Houston, Texas
| | - Jahnavi Gollamudi
- Center for Translational Research on Inflammatory Diseases (CTRID), Michael E. DeBakey VA Medical Center, Houston, Texas; Baylor College of Medicine, Houston, Texas
| | - Rolando E Rumbaut
- Center for Translational Research on Inflammatory Diseases (CTRID), Michael E. DeBakey VA Medical Center, Houston, Texas; Baylor College of Medicine, Houston, Texas.
| |
Collapse
|
26
|
Li T, Yang S, Hu F, Geng Q, Lu Q, Ding J. Effects of ankle pump exercise frequency on venous hemodynamics of the lower limb. Clin Hemorheol Microcirc 2020; 76:111-120. [PMID: 32538827 DOI: 10.3233/ch-200860] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE The purpose of this study was (1) to compare the effects of ankle pump exercise(APE) frequency on hemodynamics of the common femoral vein(CFV) and (2) to analyse the relationship between APE duration and lower limb fatigue. METHODS Twenty-seven males and thirty-three females performed APE. Among them, there were thirty participants with non-lower limb fracture (N-LLF) and thirty participants with lower limb fracture (LLF).The colour doppler ultrasound was used to record the time-averaged mean velocity (TAMV) of common femoral venous flow when the participants at rest and move at different frequencies of 6 times/min, 10 times/min, 30 times/min, 60 times/min. The ratings of perceived exertion (RPE) was used to assess the lower limb fatigue of the participants when performing APE at the frequency of 60 times/min after 1 min, 2 mins, 3 mins, 4 mins and 5 mins. RESULTS With the increase of frequency, TAMV increased significantly in both the participants with N-LLF and LLF (p < 0.01). The TAMV were 19.82±3.86, 33.78±8.76, 37.06±8.67, 43.82±10.40, 52.18±10.53, respectively in the participants with N-LLF and 16.98±3.01, 22.20±4.96, 24.01±5.78, 29.20±7.05, 35.75±9.28, respectively in the injured limb of patients with LLF when at rest and moving at the frequency of 6 times/min, 10 times/min, 30 times/min, 60 times/min. There was a positive correlation (p < 0.01) between lower limb fatigue and exercise duration.When the RPE was 16 points (the corresponding fatigue degree is "tired"), the exercise duration of the participants with N-LLF was 3 mins and that of the injured limb of patients with LLF was 2 mins. CONCLUSIONS Both fast and slow-frequency APE can promote venous blood return in the lower limb. Despite of the equivalent APE duration, fast-frequency APE can promote venous blood return more effectively. When the frequency of APE was 60 times/min, participants with N-LLF can exercise for 3 mins, and the injured limb of patients with LLF can exercise for 2 mins.
Collapse
Affiliation(s)
- Tianhua Li
- Third Hospital of Hebei Medical University, Shijiazhaung, China
| | - Shuhong Yang
- Third Hospital of Hebei Medical University, Shijiazhaung, China
| | - Fang Hu
- Third Hospital of Hebei Medical University, Shijiazhaung, China
| | - Qian Geng
- Third Hospital of Hebei Medical University, Shijiazhaung, China
| | - Qing Lu
- Third Hospital of Hebei Medical University, Shijiazhaung, China
| | - Junqin Ding
- Third Hospital of Hebei Medical University, Shijiazhaung, China
| |
Collapse
|
27
|
de la Harpe KM, Kondiah PPD, Choonara YE, Marimuthu T, du Toit LC, Pillay V. The Hemocompatibility of Nanoparticles: A Review of Cell-Nanoparticle Interactions and Hemostasis. Cells 2019; 8:E1209. [PMID: 31591302 PMCID: PMC6829615 DOI: 10.3390/cells8101209] [Citation(s) in RCA: 168] [Impact Index Per Article: 33.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Revised: 10/01/2019] [Accepted: 10/03/2019] [Indexed: 12/12/2022] Open
Abstract
Understanding cell-nanoparticle interactions is critical to developing effective nanosized drug delivery systems. Nanoparticles have already advanced the treatment of several challenging conditions including cancer and human immunodeficiency virus (HIV), yet still hold the potential to improve drug delivery to elusive target sites. Even though most nanoparticles will encounter blood at a certain stage of their transport through the body, the interactions between nanoparticles and blood cells is still poorly understood and the importance of evaluating nanoparticle hemocompatibility is vastly understated. In contrast to most review articles that look at the interference of nanoparticles with the intricate coagulation cascade, this review will explore nanoparticle hemocompatibility from a cellular angle. The most important functions of the three cellular components of blood, namely erythrocytes, platelets and leukocytes, in hemostasis are highlighted. The potential deleterious effects that nanoparticles can have on these cells are discussed and insight is provided into some of the complex mechanisms involved in nanoparticle-blood cell interactions. Throughout the review, emphasis is placed on the importance of undertaking thorough, all-inclusive hemocompatibility studies on newly engineered nanoparticles to facilitate their translation into clinical application.
Collapse
Affiliation(s)
- Kara M de la Harpe
- Wits Advanced Drug Delivery Platform Research Unit, Department of Pharmacy and Pharmacology, School of Therapeutic Science, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 7 York Road, Parktown 2193, South Africa.
| | - Pierre P D Kondiah
- Wits Advanced Drug Delivery Platform Research Unit, Department of Pharmacy and Pharmacology, School of Therapeutic Science, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 7 York Road, Parktown 2193, South Africa
| | - Yahya E Choonara
- Wits Advanced Drug Delivery Platform Research Unit, Department of Pharmacy and Pharmacology, School of Therapeutic Science, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 7 York Road, Parktown 2193, South Africa.
| | - Thashree Marimuthu
- Wits Advanced Drug Delivery Platform Research Unit, Department of Pharmacy and Pharmacology, School of Therapeutic Science, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 7 York Road, Parktown 2193, South Africa.
| | - Lisa C du Toit
- Wits Advanced Drug Delivery Platform Research Unit, Department of Pharmacy and Pharmacology, School of Therapeutic Science, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 7 York Road, Parktown 2193, South Africa.
| | - Viness Pillay
- Wits Advanced Drug Delivery Platform Research Unit, Department of Pharmacy and Pharmacology, School of Therapeutic Science, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 7 York Road, Parktown 2193, South Africa.
| |
Collapse
|
28
|
Cheng AL, Wee CP, Pahlevan NM, Wood JC. A 4D flow MRI evaluation of the impact of shear-dependent fluid viscosity on in vitro Fontan circulation flow. Am J Physiol Heart Circ Physiol 2019; 317:H1243-H1253. [PMID: 31585044 DOI: 10.1152/ajpheart.00296.2019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The Fontan procedure for univentricular heart defects creates a nonphysiologic circulation where systemic venous blood drains directly into the pulmonary arteries, leading to multiorgan dysfunction secondary to chronic low-shear nonpulsatile pulmonary blood flow and central venous hypertension. Although blood viscosity increases exponentially in this low-shear environment, the role of shear-dependent ("non-Newtonian") blood viscosity in this pathophysiology is unclear. We studied three-dimensional (3D)-printed Fontan models in an in vitro flow loop with a Philips 3-T magnetic resonance imaging (MRI) scanner. A 4D flow phase-contrast sequence was used to acquire a time-varying 3D velocity field for each experimental condition. On the basis of blood viscosity of a cohort of patients who had undergone the Fontan procedure, it was decided to use 0.04% xanthan gum as a non-Newtonian blood analog; 45% glycerol was used as a Newtonian control fluid. MRI data were analyzed using GTFlow and MATLAB software. The primary outcome, power loss, was significantly higher with the Newtonian fluid [14.8 (13.3, 16.4) vs. 8.1 (6.4, 9.8)%, medians with 95% confidence interval, P < 0.0001]. The Newtonian fluid also demonstrated marginally higher right pulmonary artery flow, marginally lower shear stress, and a trend toward higher caval flow mixing. Outcomes were modulated by Fontan model complexity, cardiac output, and caval flow ratio. Vortexes, helical flow, and stagnant flow were more prevalent with the non-Newtonian fluid. Our data demonstrate that shear-dependent viscosity significantly alters qualitative flow patterns, power loss, pulmonary flow distribution, shear stress, and caval flow mixing in synthetic models of the Fontan circulation. Potential clinical implications include effects on exercise capacity, ventilation-perfusion matching, risk of pulmonary arteriovenous malformations, and risk of thromboembolism.NEW & NOTEWORTHY Although blood viscosity increases exponentially in low-shear environments, the role of shear-dependent ("non-Newtonian") blood viscosity in the pathophysiology of the low-shear Fontan circulation is unclear. We demonstrate that shear-dependent viscosity significantly alters qualitative flow patterns, power loss, pulmonary flow distribution, shear stress, and caval flow mixing in synthetic models of the Fontan circulation. Potential clinical implications include effects on exercise capacity, ventilation-perfusion matching, risk of pulmonary arteriovenous malformations, and risk of thromboembolism.
Collapse
Affiliation(s)
- Andrew L Cheng
- Division of Pediatric Cardiology, Children's Hospital Los Angeles, Los Angeles, California.,Keck School of Medicine, University of Southern California, Los Angeles, California
| | - Choo Phei Wee
- Biostatistics Core, Children's Hospital Los Angeles, Los Angeles, California
| | - Niema M Pahlevan
- Keck School of Medicine, University of Southern California, Los Angeles, California.,Department of Aerospace and Mechanical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California
| | - John C Wood
- Division of Pediatric Cardiology, Children's Hospital Los Angeles, Los Angeles, California.,Keck School of Medicine, University of Southern California, Los Angeles, California
| |
Collapse
|
29
|
Experimental and Numerical Study of Blood Flow in μ-vessels: Influence of the Fahraeus–Lindqvist Effect. FLUIDS 2019. [DOI: 10.3390/fluids4030143] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The study of hemodynamics is particularly important in medicine and biomedical engineering as it is crucial for the design of new implantable devices and for understanding the mechanism of various diseases related to blood flow. In this study, we experimentally identify the cell free layer (CFL) width, which is the result of the Fahraeus–Lindqvist effect, as well as the axial velocity distribution of blood flow in microvessels. The CFL extent was determined using microscopic photography, while the blood velocity was measured by micro-particle image velocimetry (μ-PIV). Based on the experimental results, we formulated a correlation for the prediction of the CFL width in small caliber (D < 300 μm) vessels as a function of a modified Reynolds number (Re∞) and the hematocrit (Hct). This correlation along with the lateral distribution of blood viscosity were used as input to a “two-regions” computational model. The reliability of the code was checked by comparing the experimentally obtained axial velocity profiles with those calculated by the computational fluid dynamics (CFD) simulations. We propose a methodology for calculating the friction loses during blood flow in μ-vessels, where the Fahraeus–Lindqvist effect plays a prominent role, and show that the pressure drop may be overestimated by 80% to 150% if the CFL is neglected.
Collapse
|
30
|
Agarwal R, Sarkar A, Chakraborty S. Interplay of Coriolis effect with rheology results in unique blood dynamics on a compact disc. Analyst 2019; 144:3782-3789. [PMID: 31094378 DOI: 10.1039/c9an00645a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We investigate the influence of rotational forces on blood dynamics in a microfluidic device. The special confluence of Coriolis force and blood rheology is brought forth by analyzing the flow at different hematocrit (volume fraction of red blood cells) levels and rotational speeds. We further study the effects of channel layout and alignment with regard to the axis of rotation to understand this intricate interplay. We provide a sound basis for efficient designing of a lab on a compact disc (lab on CD) platform by harnessing the effects of Coriolis force at relatively much lower rotational speeds, in sharp contrast with the reported findings where Coriolis effects have been considered to be effective only for exceptionally high rotational speeds. Our results show that over certain intermediate regimes of rotational speeds, the flow profiles for different hematocrit levels are noticeably different. This, in turn, could be harnessed as a possible diagnostic signature of the hematocrit (or equivalently, packed cell volume) level, without necessitating the deployment of chemical consumables, in an energy efficient paradigm.
Collapse
Affiliation(s)
- Rahul Agarwal
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur - 721302, India.
| | | | | |
Collapse
|
31
|
The influence of hematocrit on the hemodynamics of artificial heart valve using fluid-structure interaction analysis. Comput Biol Med 2019; 110:79-92. [DOI: 10.1016/j.compbiomed.2019.05.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2019] [Accepted: 05/01/2019] [Indexed: 01/10/2023]
|
32
|
Feiger B, Vardhan M, Gounley J, Mortensen M, Nair P, Chaudhury R, Frakes D, Randles A. Suitability of lattice Boltzmann inlet and outlet boundary conditions for simulating flow in image-derived vasculature. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2019; 35:e3198. [PMID: 30838793 PMCID: PMC7605305 DOI: 10.1002/cnm.3198] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Revised: 12/18/2018] [Accepted: 03/03/2019] [Indexed: 06/09/2023]
Abstract
The lattice Boltzmann method (LBM) is a popular alternative to solving the Navier-Stokes equations for modeling blood flow. When simulating flow using the LBM, several choices for inlet and outlet boundary conditions exist. While boundary conditions in the LBM have been evaluated in idealized geometries, there have been no extensive comparisons in image-derived vasculature, where the geometries are highly complex. In this study, the Zou-He (ZH) and finite difference (FD) boundary conditions were evaluated in image-derived vascular geometries by comparing their stability, accuracy, and run times. The boundary conditions were compared in four arteries: a coarctation of the aorta, dissected aorta, femoral artery, and left coronary artery. The FD boundary condition was more stable than ZH in all four geometries. In general, simulations using the ZH and FD method showed similar convergence rates within each geometry. However, the ZH method proved to be slightly more accurate compared with experimental flow using three-dimensional printed vasculature. The total run times necessary for simulations using the ZH boundary condition were significantly higher as the ZH method required a larger relaxation time, grid resolution, and number of time steps for a simulation representing the same physiological time. Finally, a new inlet velocity profile algorithm is presented for complex inlet geometries. Overall, results indicated that the FD method should generally be used for large-scale blood flow simulations in image-derived vasculature geometries. This study can serve as a guide to researchers interested in using the LBM to simulate blood flow.
Collapse
Affiliation(s)
- Bradley Feiger
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Madhurima Vardhan
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - John Gounley
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Matthew Mortensen
- Department of Biomedical Engineering, Arizona State University, Tempe, AZ, USA
| | - Priya Nair
- Department of Biomedical Engineering, Arizona State University, Tempe, AZ, USA
| | - Rafeed Chaudhury
- Department of Biomedical Engineering, Arizona State University, Tempe, AZ, USA
| | - David Frakes
- Department of Biomedical Engineering, Arizona State University, Tempe, AZ, USA
| | - Amanda Randles
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| |
Collapse
|
33
|
Balogh P, Bagchi P. Three-dimensional distribution of wall shear stress and its gradient in red cell-resolved computational modeling of blood flow in in vivo-like microvascular networks. Physiol Rep 2019; 7:e14067. [PMID: 31062494 PMCID: PMC6503071 DOI: 10.14814/phy2.14067] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 03/20/2019] [Accepted: 03/25/2019] [Indexed: 01/13/2023] Open
Abstract
Using a high-fidelity, 3D computational model of blood flow in microvascular networks, we provide the full 3D distribution of wall shear stress (WSS), and its gradient (WSSG), and quantify the influence of red blood cells (RBCs) on WSS and WSSG. The deformation and flow dynamics of the individual RBCs are accurately resolved in the model, while physiologically realistic microvascular networks comprised of multiple bifurcations, convergences, and tortuous vessels are considered. A strong heterogeneity in WSS and WSSG is predicted across the networks, with the highest WSS occurring in precapillary bifurcations and capillary vessels. 3D variations of WSS and WSSG are shown to occur due to both network morphology and the influence of RBCs. The RBCs increase the WSS by as much as three times compared to that when no RBCs are present, and the highest increase is observed in venules. WSSG also increases significantly, and high WSSGs occur over wider regions in the presence of RBCs. In most vessels, the circumferential component of WSSG is observed to be greater than the axial component in the presence of RBCs, while the opposite trend is observed when RBCs are not considered. These results underscore the important role of RBCs on WSS and WSSG that cannot be predicted by widely used 1D models of network blood flow. Furthermore, the subendothelium-scale variations of WSS and WSSG predicted by the present model have implications in terms of endothelial cell functions in the microvasculature.
Collapse
Affiliation(s)
- Peter Balogh
- Mechanical and Aerospace Engineering DepartmentRutgers, The State University of New JerseyPiscatawayNew Jersey
| | - Prosenjit Bagchi
- Mechanical and Aerospace Engineering DepartmentRutgers, The State University of New JerseyPiscatawayNew Jersey
| |
Collapse
|
34
|
Seymour RS, Hu Q, Snelling EP, White CR. Interspecific scaling of blood flow rates and arterial sizes in mammals. ACTA ACUST UNITED AC 2019; 222:jeb.199554. [PMID: 30877224 DOI: 10.1242/jeb.199554] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Accepted: 03/07/2019] [Indexed: 01/16/2023]
Abstract
This meta-study investigated the relationships between blood flow rate (Q̇; cm3 s-1), wall shear stress (τw; dyn cm-2) and lumen radius (r i; cm) in 20 named systemic arteries of nine species of mammals, ranging in mass from 23 g mice to 652 kg cows, at rest. In the dataset, derived from 50 studies, lumen radius varied between 3.7 µm in a cremaster artery of a rat and 11.2 mm in the aorta of a human. The 92 logged data points of [Formula: see text] and r i are described by a single second-order polynomial curve with the equation: [Formula: see text] The slope of the curve increased from approximately 2 in the largest arteries to approximately 3 in the smallest ones. Thus, da Vinci's rule ([Formula: see text]) applies to the main arteries and Murray's law ([Formula: see text]) applies to the microcirculation. A subset of the data, comprising only cephalic arteries in which [Formula: see text] is fairly constant, yielded the allometric power equation: [Formula: see text] These empirical equations allow calculation of resting perfusion rates from arterial lumen size alone, without reliance on theoretical models or assumptions on the scaling of wall shear stress in relation to body mass. As expected, [Formula: see text] of individual named arteries is strongly affected by body mass; however, [Formula: see text] of the common carotid artery from six species (mouse to horse) is also sensitive to differences in whole-body basal metabolic rate, independent of the effect of body mass.
Collapse
Affiliation(s)
- Roger S Seymour
- School of Biological Sciences, Faculty of Sciences, University of Adelaide, Adelaide, SA 5005, Australia
| | - Qiaohui Hu
- School of Biological Sciences, Faculty of Sciences, University of Adelaide, Adelaide, SA 5005, Australia
| | - Edward P Snelling
- Department of Anatomy and Physiology, Faculty of Veterinary Science, University of Pretoria, Onderstepoort, Gauteng 0110, South Africa.,Brain Function Research Group, School of Physiology, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, Gauteng 2193, South Africa
| | - Craig R White
- Centre for Geometric Biology, School of Biological Sciences, Faculty of Science, Monash University, Clayton, VIC 3800, Australia
| |
Collapse
|
35
|
Kadri OE, Chandran VD, Surblyte M, Voronov RS. In vivo measurement of blood clot mechanics from computational fluid dynamics based on intravital microscopy images. Comput Biol Med 2019; 106:1-11. [PMID: 30660757 PMCID: PMC6390965 DOI: 10.1016/j.compbiomed.2019.01.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 01/04/2019] [Accepted: 01/04/2019] [Indexed: 12/31/2022]
Abstract
Ischemia which leads to heart attacks and strokes is one of the major causes of death in the world. Whether an occlusion occurs or not depends on the ability of a growing thrombus to resist flow forces exerted on its structure. This manuscript provides the first known in vivo measurement of how much stress a clot can withstand, before yielding to the surrounding blood flow. Namely, Lattice-Boltzmann Method flow simulations are performed based on 3D clot geometries, which are estimated from intravital microscopy images of laser-induced injuries in cremaster microvasculature of live mice. In addition to reporting the blood clot yield stresses, we also show that the thrombus "core" does not experience significant deformation, while its "shell" does. This indicates that the shell is more prone to embolization. Therefore, drugs should be designed to target the shell selectively, while leaving the core intact to minimize excessive bleeding. Finally, we laid down a foundation for a nondimensionalization procedure which unraveled a relationship between clot mechanics and biology. Hence, the proposed framework could ultimately lead to a unified theory of thrombogenesis, capable of explaining all clotting events. Thus, the findings presented herein will be beneficial to the understanding and treatment of heart attacks, strokes and hemophilia.
Collapse
Affiliation(s)
- Olufemi Emmanuel Kadri
- Otto H. York Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ, 07102, USA
| | - Vishnu Deep Chandran
- Otto H. York Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ, 07102, USA
| | - Migle Surblyte
- Ying Wu College of Computing Sciences, Department of Computer Science, New Jersey Institute of Technology, Newark, NJ, 07102, USA
| | - Roman S Voronov
- Otto H. York Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ, 07102, USA.
| |
Collapse
|
36
|
Chakraborty S. Electrokinetics with blood. Electrophoresis 2018; 40:180-189. [DOI: 10.1002/elps.201800353] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 09/13/2018] [Accepted: 09/14/2018] [Indexed: 11/08/2022]
Affiliation(s)
- Suman Chakraborty
- Department of Mechanical Engineering; Indian Institute of Technology Kharagpur; Kharagpur India
| |
Collapse
|
37
|
Dynamics of blood flow: modeling of Fåhraeus and Fåhraeus-Lindqvist effects using a shear-induced red blood cell migration model. J Biol Phys 2018; 44:591-603. [PMID: 30219980 DOI: 10.1007/s10867-018-9508-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Accepted: 08/08/2018] [Indexed: 10/28/2022] Open
Abstract
Blood flow in micro capillaries of diameter approximately 15-500 μm is accompanied with a lower tube hematocrit level and lower apparent viscosity as the diameter decreases. These effects are termed the Fåhraeus and Fåhraeus-Lindqvist effects, respectively. Both effects are linked to axial accumulation of red blood cells. In the present investigation, we extend previous works using a shear-induced model for the migration of red blood cells and adopt a model for blood viscosity that accounts for the suspending medium viscosity and local hematocrit level. For fully developed hematocrit profiles (i.e., independent of axial location), the diffusion fluxes due to particle collision frequency and viscosity gradients are of equal magnitude and opposite directions. The ratio of the diffusion coefficients for the two fluxes affects both the Fåhraeus and Fåhraeus-Lindqvist effects and is found related to the capillary diameter and discharge hematocrit using a well-known data-fit correlation for apparent blood viscosity. The velocity and hematocrit profiles were determined numerically as functions of radial coordinate, tube diameter, and discharge hematocrit. The velocity profile determined numerically is consistent with the derived analytical expression and the results are in good agreement with published numerical results and experimental data for hematocrit ratio and hematocrit and velocity profiles.
Collapse
|
38
|
Cheng AL, Pahlevan NM, Rinderknecht DG, Wood JC, Gharib M. Experimental Investigation of the Effect of Non-Newtonian Behavior of Blood Flow in the Fontan Circulation. EUROPEAN JOURNAL OF MECHANICS. B, FLUIDS 2018; 68:184-192. [PMID: 29736127 PMCID: PMC5935448 DOI: 10.1016/j.euromechflu.2017.12.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The Fontan procedure for univentricular heart defects creates a unique circulation where all pulmonary blood flow is passively supplied directly from systemic veins. Computational simulations, aimed at optimizing the surgery, have assumed blood to be a Newtonian fluid without evaluating the potential error introduced by this assumption. We compared flow behavior between a non-Newtonian blood analog (0.04% xanthan gum) and a control Newtonian fluid (45% glycerol) in a simplified model of the Fontan circulation. Particle image velocimetry was used to examine flow behavior at two different cardiac outputs and two caval blood flow distributions. Pressure and flow rates were measured at each inlet and outlet. Velocity, shear strain, and shear stress maps were derived from velocity data. Power loss was calculated from pressure, flow, and velocity data. Power loss was increased in all test conditions with xanthan gum vs. glycerol (mean 10±2.9% vs. 5.6±1.3%, p=0.032). Pulmonary blood flow distribution differed in all conditions, more so at low cardiac output. Caval blood flow mixing patterns and shear stress were also qualitatively different between the solutions in all conditions. We conclude that assuming blood to be a Newtonian fluid introduces considerable error into simulations of the Fontan circulation, where low-shear flow predominates.
Collapse
Affiliation(s)
- Andrew L. Cheng
- Division of Pediatric Cardiology, Department of Pediatrics, Children's Hospital Los Angeles, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Niema M. Pahlevan
- Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA, USA
- Huntington Medical Research Institutes, Pasadena, CA, USA
| | - Derek G. Rinderknecht
- Graduate Aerospace Laboratories, California Institute of Technology, Pasadena, CA, USA
| | - John C. Wood
- Division of Pediatric Cardiology, Department of Pediatrics, Children's Hospital Los Angeles, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Morteza Gharib
- Graduate Aerospace Laboratories, California Institute of Technology, Pasadena, CA, USA
- Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
| |
Collapse
|
39
|
Belcher DA, Ju JA, Baek JH, Yalamanoglu A, Buehler PW, Gilkes DM, Palmer AF. The quaternary state of polymerized human hemoglobin regulates oxygenation of breast cancer solid tumors: A theoretical and experimental study. PLoS One 2018; 13:e0191275. [PMID: 29414985 PMCID: PMC5802857 DOI: 10.1371/journal.pone.0191275] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Accepted: 01/02/2018] [Indexed: 11/19/2022] Open
Abstract
A major constraint in the treatment of cancer is inadequate oxygenation of the tumor mass, which can reduce chemotherapeutic efficacy. We hypothesize that polymerized human hemoglobin (PolyhHb) can be transfused into the systemic circulation to increase solid tumor oxygenation, and improve chemotherapeutic outcomes. By locking PolyhHb in the relaxed (R) quaternary state, oxygen (O2) offloading at low O2 tensions (<20 mm Hg) may be increased, while O2 offloading at high O2 tensions (>20 mm Hg) is facilitated with tense (T) state PolyhHb. Therefore, R-state PolyhHb may deliver significantly more O2 to hypoxic tissues. Biophysical parameters of T and R-state PolyhHb were used to populate a modified Krogh tissue cylinder model to assess O2 transport in a tumor. In general, we found that increasing the volume of transfused PolyhHb decreased the apparent viscosity of blood in the arteriole. In addition, we found that PolyhHb transfusion decreased the wall shear stress at large arteriole diameters (>20 μm), but increased wall shear stress for small arteriole diameters (<10 μm). Therefore, transfusion of PolyhHb may lead to elevated O2 delivery at low pO2. In addition, transfusion of R-state PolyhHb may be more effective than T-state PolyhHb for O2 delivery at similar transfusion volumes. Reduction in the apparent viscosity resulting from PolyhHb transfusion may result in significant changes in flow distributions throughout the tumor microcirculatory network. The difference in wall shear stress implies that PolyhHb may have a more significant effect in capillary beds through mechano-transduction. Periodic top-load transfusions of PolyhHb into mice bearing breast tumors confirmed the oxygenation potential of both PolyhHbs via reduced hypoxic volume, vascular density, tumor growth, and increased expression of hypoxia inducible genes. Tissue section analysis demonstrated primary PolyhHb clearance occurred in the liver and spleen indicating a minimal risk for renal damage.
Collapse
Affiliation(s)
- Donald A. Belcher
- William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, OH, United States of America
| | - Julia A. Ju
- Department of Chemical and Biomolecular Engineering, The Johns Hopkins University, Baltimore, MD, United States of America
| | - Jin Hyen Baek
- Division of Blood Components and Devices, Laboratory of Biochemistry and Vascular Biology, FDA/CBER, Silver Spring, MD, United States of America
| | - Ayla Yalamanoglu
- Division of Blood Components and Devices, Laboratory of Biochemistry and Vascular Biology, FDA/CBER, Silver Spring, MD, United States of America
| | - Paul W. Buehler
- Division of Blood Components and Devices, Laboratory of Biochemistry and Vascular Biology, FDA/CBER, Silver Spring, MD, United States of America
| | - Daniele M. Gilkes
- Department of Chemical and Biomolecular Engineering, The Johns Hopkins University, Baltimore, MD, United States of America
- Department of Oncology, The Johns Hopkins University School of Medicine, Baltimore, MD, United States of America
| | - Andre F. Palmer
- William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, OH, United States of America
| |
Collapse
|
40
|
Dynamic, heterogeneous endothelial Tie2 expression and capillary blood flow during microvascular remodeling. Sci Rep 2017; 7:9049. [PMID: 28831080 PMCID: PMC5567377 DOI: 10.1038/s41598-017-08982-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 07/20/2017] [Indexed: 12/20/2022] Open
Abstract
Microvascular endothelial cell heterogeneity and its relationship to hemodynamics remains poorly understood due to a lack of sufficient methods to examine these parameters in vivo at high resolution throughout an angiogenic network. The availability of surrogate markers for functional vascular proteins, such as green fluorescent protein, enables expression in individual cells to be followed over time using confocal microscopy, while photoacoustic microscopy enables dynamic measurement of blood flow across the network with capillary-level resolution. We combined these two non-invasive imaging modalities in order to spatially and temporally analyze biochemical and biomechanical drivers of angiogenesis in murine corneal neovessels. By stimulating corneal angiogenesis with an alkali burn in Tie2-GFP fluorescent-reporter mice, we evaluated how onset of blood flow and surgically-altered blood flow affects Tie2-GFP expression. Our study establishes a novel platform for analyzing heterogeneous blood flow and fluorescent reporter protein expression across a dynamic microvascular network in an adult mammal.
Collapse
|
41
|
Posttransfusion Increase of Hematocrit per se Does Not Improve Circulatory Oxygen Delivery due to Increased Blood Viscosity. Anesth Analg 2017; 124:1547-1554. [PMID: 28328758 DOI: 10.1213/ane.0000000000002008] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Blood transfusion is used to treat acute anemia with the goal of increasing blood oxygen-carrying capacity as determined by hematocrit (Hct) and oxygen delivery (DO2). However, increasing Hct also increases blood viscosity, which may thus lower DO2 if the arterial circulation is a rigid hydraulic system as the resistance to blood flow will increase. The net effect of transfusion on DO2 in this system can be analyzed by using the relationship between Hct and systemic blood viscosity of circulating blood at the posttransfusion Hct to calculate DO2 and comparing this value with pretransfusion DO2. We hypothesized that increasing Hct would increase DO2 and tested our hypothesis by mathematically modeling DO2 in the circulation. METHODS Calculations were made assuming a normal cardiac output (5 L/min) with degrees of anemia ranging from 5% to 80% Hct deficit. We analyzed the effects of transfusing 0.5 or more units of 300 cc of packed red blood cells (PRBCs) at an Hct of 65% and calculated microcirculatory DO2 after accounting for increased blood viscosity and assuming no change in blood pressure. Our model accounts for O2 diffusion out of the circulation before blood arriving to the nutritional circulation and for changes in blood flow velocity. The immediate posttransfusion DO2 was also compared with DO2 after the transient increase in volume due to transfusion has subsided. RESULTS Blood transfusion of up to 3 units of PRBCs increased DO2 when Hct (or hemoglobin) was 60% lower than normal, but did not increase DO2 when administered before this threshold. CONCLUSIONS After accounting for the effect of increasing blood viscosity on blood flow owing to increasing Hct, we found in a mathematical simulation of DO2 that transfusion of up to 3 units of PRBCs does not increase DO2, unless anemia is the result of an Hct deficit greater than 60%. Observations that transfusions occasionally result in clinical improvement suggest that other mechanisms possibly related to increased blood viscosity may compensate for the absence of increase in DO2.
Collapse
|
42
|
C. Arciero J, Causin P, Malgaroli F. Mathematical methods for modeling the microcirculation. AIMS BIOPHYSICS 2017. [DOI: 10.3934/biophy.2017.3.362] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
43
|
Al-Khazraji BK, Jackson DN, Goldman D. A Microvascular Wall Shear Rate Function Derived From In Vivo Hemodynamic and Geometric Parameters in Continuously Branching Arterioles. Microcirculation 2016; 23:311-9. [PMID: 27018869 DOI: 10.1111/micc.12279] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Accepted: 03/26/2016] [Indexed: 12/26/2022]
Abstract
OBJECTIVES Conventional approaches to WSR estimation in the microcirculation involve assumptions that may result in under-/over-estimation of WSR. Therefore, our objectives were: (i) calculate WSR from RBC velocity profiles for a wide range of arteriolar diameters, (ii) provide an experimentally derived and straightforward WSR estimation function, and (iii) compare calculated to conventional WSR estimations. METHODS We characterized RBC velocity profiles in arterioles (n = 39) of branching networks (21-115 μm) in the rat gluteus maximus muscle (n = 6). Measures included mean and maximum velocities, CFL thickness, and RBC column edge velocity, and an experiment-based WSR function was derived. RESULTS CFL thickness (1-4.3 μm) positively correlated with arteriolar diameter (r(2) = 0.64). Results from the WSR equation were similar to values from edge RBC velocities/CFL. Experimental WSRs (1317-4334/sec) were independent of arteriolar diameter, and were greater than pseudoshear rates (for VRatio of 1.6, 2, or diameter-dependent VRatio function) (p < 0.05). CONCLUSION A WSR equation was derived from experimental hemodynamic parameters, and is adaptable to other velocity measurement techniques in order to obtain WSR and stress (when plasma viscosity is known). These findings provide insight on the nature of conventional WSR calculation methods in underestimating microvascular WSR values.
Collapse
Affiliation(s)
- Baraa K Al-Khazraji
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - Dwayne N Jackson
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada.,Biomedical Engineering Graduate Program, The University of Western Ontario, London, Ontario, Canada
| | - Daniel Goldman
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada.,Biomedical Engineering Graduate Program, The University of Western Ontario, London, Ontario, Canada
| |
Collapse
|
44
|
Little R, Cartwright EJ, Neyses L, Austin C. Plasma membrane calcium ATPases (PMCAs) as potential targets for the treatment of essential hypertension. Pharmacol Ther 2016; 159:23-34. [PMID: 26820758 DOI: 10.1016/j.pharmthera.2016.01.013] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
The incidence of hypertension, the major modifiable risk factor for cardiovascular disease, is increasing. Thus, there is a pressing need for the development of new and more effective strategies to prevent and treat hypertension. Development of these relies on a continued evolution of our understanding of the mechanisms which control blood pressure (BP). Resistance arteries are important in the regulation of total peripheral resistance and BP; changes in their structure and function are strongly associated with hypertension. Anti-hypertensives which both reduce BP and reverse changes in resistance arterial structure reduce cardiovascular risk more than therapies which reduce BP alone. Hence, identification of novel potential vascular targets which modify BP is important. Hypertension is a multifactorial disorder which may include a genetic component. Genome wide association studies have identified ATP2B1, encoding the calcium pump plasma membrane calcium ATPase 1 (PMCA1), as having a strong association with BP and hypertension. Knockdown or reduced PMCA1 expression in mice has confirmed a physiological role for PMCA1 in BP and resistance arterial regulation. Altered expression or inhibition of PMCA4 has also been shown to modulate these parameters. The mechanisms whereby PMCA1 and 4 can modulate vascular function remain to be fully elucidated but may involve regulation of intracellular calcium homeostasis and/or comprise a structural role. However, clear physiological links between PMCA and BP, coupled with experimental studies directly linking PMCA1 and 4 to changes in BP and arterial function, suggest that they may be important targets for the development of new pharmacological modulators of BP.
Collapse
Affiliation(s)
- Robert Little
- The Institute of Cardiovascular Sciences, The University of Manchester, UK
| | | | - Ludwig Neyses
- The Institute of Cardiovascular Sciences, The University of Manchester, UK
| | - Clare Austin
- Faculty of Health and Social Care, Edge Hill University, UK.
| |
Collapse
|
45
|
Longo S, Di Federico V, Chiapponi L. Propagation of viscous gravity currents inside confining boundaries: the effects of fluid rheology and channel geometry. Proc Math Phys Eng Sci 2015. [DOI: 10.1098/rspa.2015.0070] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
A theoretical and experimental investigation of the propagation of free-surface, channelized viscous gravity currents is conducted to examine the combined effects of fluid rheology, boundary geometry and channel inclination. The fluid is characterized by a power-law constitutive equation with behaviour index
n
. The channel cross section is limited by a rigid boundary of height parametrized by
k
and has a longitudinal variation described by the constant
b
≥0. The cases
k
⋛
1
are associated with wide, triangular and narrow cross sections. For
b
>0, the cases
k
≷
1
describe widening channels and squeezing fractures;
b
=0 implies a constant cross-sectional channel. For a volume of released fluid varying with time like
t
α
, scalings for current length and thickness are obtained in self-similar forms for horizontal and inclined channels/fractures. The speed, thickness and aspect ratio of the current jointly depend on the total current volume (
α
), the fluid rheological behaviour (
n
), and the transversal (
k
) and longitudinal (
b
) geometry of the channel. The asymptotic validity of the solutions is limited to certain ranges of parameters. Experimental validation was performed with different fluids and channel cross sections; experimental results for current radius and profile were found to be in close agreement with the self-similar solutions at intermediate and late times.
Collapse
Affiliation(s)
- S. Longo
- Dipartimento di Ingegneria Civile, Ambiente, Territorio e Architettura (DICATeA), Università di Parma, Parco Area delle Scienze, 181/A, 43124 Parma, Italy
| | - V. Di Federico
- Dipartimento di Ingegneria Civile, Chimica, Ambientale e dei Materiali (DICAM), Università di Bologna, Viale Risorgimento, 2, 40136 Bologna, Italy
| | - L. Chiapponi
- Dipartimento di Ingegneria Civile, Ambiente, Territorio e Architettura (DICATeA), Università di Parma, Parco Area delle Scienze, 181/A, 43124 Parma, Italy
| |
Collapse
|
46
|
Zuidema MY, Korthuis RJ. Intravital microscopic methods to evaluate anti-inflammatory effects and signaling mechanisms evoked by hydrogen sulfide. Methods Enzymol 2015; 555:93-125. [PMID: 25747477 PMCID: PMC4722536 DOI: 10.1016/bs.mie.2014.11.022] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Hydrogen sulfide (H2S) is an endogenous gaseous signaling molecule with potent anti-inflammatory properties. Exogenous application of H2S donors, administered either acutely during an inflammatory response or as an antecedent preconditioning intervention that invokes the activation of anti-inflammatory cell survival programs, effectively limits leukocyte rolling, adhesion and emigration, generation of reactive oxygen species, chemokine and cell adhesion molecule expression, endothelial barrier disruption, capillary perfusion deficits, and parenchymal cell dysfunction and injury. This chapter focuses on intravital microscopic methods that can be used to assess the anti-inflammatory effects exerted by H2S, as well as to explore the cellular signaling mechanisms by which this gaseous molecule limits the aforementioned inflammatory responses. Recent advances include use of intravital multiphoton microscopy and optical biosensor technology to explore signaling mechanisms in vivo.
Collapse
Affiliation(s)
- Mozow Y Zuidema
- Harry S. Truman Veterans Administration Hospital, Cardiology, Columbia, Missouri, USA
| | - Ronald J Korthuis
- Department of Medical Pharmacology and Physiology, School of Medicine, One Hospital Drive, University of Missouri, Columbia, Missouri, USA; Dalton Cardiovascular Research Center, University of Missouri, Columbia, Missouri, USA.
| |
Collapse
|