1
|
Xian Y, Ye Y, Sun L, Shen Y, Zhang X, Lu ZL, Zhou X, Zhao J. Comparison of the quantitative contrast sensitivity function between early keratoconus and normal eyes. BMC Ophthalmol 2024; 24:458. [PMID: 39425133 PMCID: PMC11487694 DOI: 10.1186/s12886-024-03695-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 09/23/2024] [Indexed: 10/21/2024] Open
Abstract
PURPOSE To compare the characteristics of the quantitative contrast sensitivity function (qCSF) in eyes with early keratoconus (Early-KC) and normal control (NC) eyes and investigate the associated factors. DESIGN A cross-sectional study. METHODS This study included 43 eyes of 43 patients with Early-KC (including subclinical keratoconus [SKC] and forme fruste keratoconus [FFKC]) and 77 NC eyes of 77 participants with corrected distance visual acuity (CDVA) all ≥ 20/20. Contrast sensitivity (CS) was assessed using the qCSF tests. Subgroup analysis was performed according to keratoconus type(SKC and FFKC) and astigmatism(cylindrical refraction >-1.0D or ≤-1.0D). RESULTS Sex ratio, spherical refraction, and spherical equivalent (SE) varied significantly between the two groups (all P < 0.01). The area under log CSF (AULCSF), CSF Acuity, and CS at low (1.0 and 1.5 cycles per degree [cpd]) and high (12.0 and 18.0 cpd) spatial frequencies decreased significantly in the Early-KC group than that in the NC group (all P < 0.05). The subgroup analysis revealed a similar decrease in the SKC group (all P < 0.05). AULCSF, CSF Acuity, and CS at high spatial frequencies of patients with cylindrical refraction ≤-1.0D in the Early-KC group decreased significantly (all P < 0.05) than those in the NC group. The index of vertical asymmetry and index of height decentration correlated negatively with CS at 1.5 cpd (r= -0.321 and -0.306; both P < 0.05). CONCLUSIONS CS decreased significantly at low and high spatial frequencies in Early-KC, though with normal CDVA. The qCSF test can sensitively reflect visual performance in early keratoconus.
Collapse
Affiliation(s)
- Yiyong Xian
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fenyang Road, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, 200031, China
| | - Yuhao Ye
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fenyang Road, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, 200031, China
| | - Ling Sun
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fenyang Road, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, 200031, China
| | - Yang Shen
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fenyang Road, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, 200031, China
| | - Xiaoyu Zhang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fenyang Road, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, 200031, China
| | - Zhong-Lin Lu
- Division of Arts and Sciences, NYU Shanghai, Shanghai, China
- Center for Neural Science and Department of Psychology, New York University, New York, USA
- NYU-ECNU Institute of Brain and Cognitive Science, NYU Shanghai, Shanghai, 200031, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fenyang Road, Shanghai, 200031, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China.
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, 200031, China.
| | - Jing Zhao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fenyang Road, Shanghai, 200031, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China.
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, 200031, China.
| |
Collapse
|
2
|
Radner W. Toward an internationally accepted standard for reading charts. Prog Retin Eye Res 2024; 101:101262. [PMID: 38574851 DOI: 10.1016/j.preteyeres.2024.101262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 03/28/2024] [Accepted: 04/01/2024] [Indexed: 04/06/2024]
Abstract
Patients who suffer from sight-threatening eye diseases share a desire to regain a comfortable reading ability. In light of the modern advances achieved in ophthalmic diagnosis and therapy, and because a significant lack of comparability between reading charts still exists, there is an increasing need for a worldwide standard in the form of a norm for diagnostic reading charts. Already, applied advancements such as digital print, which allow a calibration of the print sizes of reading charts in correctly progressing geometric proportions by using the actual height of a lower case "x" in millimeters (x-height), and psychophysically standardizing reading charts and their test items by applying modern statistical methods have significantly contributed to establishing a norm for reading charts. In 2020, a proposal of the British delegation was accepted by the International Organization for Standardization (ISO) group "Visual Optics and Optical Instruments," and a working group was established. Bearing in mind the efforts of the ISO with regard to an international norm, this review article is intended to (a) give an overview of the historical background and related normative approaches for diagnostic reading tests used in ophthalmology and optometry, (b) explain psychophysical and technical concerns, and (c) discuss the possibilities and limits of concepts that seem relevant to developing a modern standard for reading charts.
Collapse
Affiliation(s)
- Wolfgang Radner
- Karl Landsteiner University of Health Sciences, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria; Department of Ophthalmology, University Hospital St. Pölten, Dunant-Platz 1, 3100, St. Pölten, Austria; Austrian Academy of Ophthalmology, Mollgasse 11, 1180, Vienna, Austria.
| |
Collapse
|
3
|
Ríos HA, Lövestam-Adrian M, Plainis S, Tsilimbaris M, Joussen AM, Keegan D, Charles M, Cunha-Vaz J, Midena E. Additional measures of macular function beyond visual acuity. Graefes Arch Clin Exp Ophthalmol 2024; 262:1723-1736. [PMID: 37938378 PMCID: PMC11106142 DOI: 10.1007/s00417-023-06272-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 09/29/2023] [Accepted: 10/09/2023] [Indexed: 11/09/2023] Open
Abstract
PURPOSE Visual function is a complex process in which external visual stimuli are interpreted. Patients with retinal diseases and prolonged follow-up times may experience changes in their visual function that are not detected by the standard visual acuity measure, as they are a result of other alterations in visual function. With the advancement of different methods to evaluate visual function, additional measurements have become available, and further standardization suggests that some methods may be promising for use in clinical trials or routine clinical practice. The objectives of this article are to review these additional measurements and to provide guidance on their application. METHODS The Vision Academy's membership of international retinal disease experts reviewed the literature and developed consensus recommendations for the application of additional measures of visual function in routine clinical practice or clinical trials. RESULTS Measures such as low-luminance visual acuity, contrast sensitivity, retinal fixation and microperimetry, and reading performance are measures which can complement visual acuity measurements to provide an assessment of overall visual function, including impact on patients' quality of life. Measures such as dark adaptation, color vision testing, binocular vision testing, visual recognition testing, and shape discrimination require further optimization and validation before they can be implemented in everyday clinical practice. CONCLUSION Additional measurements of visual function may help identify patients who could benefit from earlier diagnosis, detection of disease progression, and therapeutic intervention. New and additional functional clinical trial endpoints are required to fully understand the early stages of macular disease, its progression, and the response to treatment.
Collapse
Affiliation(s)
- Hernán Andrés Ríos
- Retina y Vítreo, Fundación Oftalmológica Nacional, Universidad del Rosario, Bogotá, Colombia
| | | | - Sotiris Plainis
- Laboratory of Optics and Vision, University of Crete Medical School, Heraklion, Crete, Greece
| | - Miltiadis Tsilimbaris
- Laboratory of Optics and Vision, University of Crete Medical School, Heraklion, Crete, Greece
| | | | - David Keegan
- Department of Ophthalmology, Mater Misericordiae University Hospital, Dublin, Ireland
| | | | - José Cunha-Vaz
- AIBILI - Association for Innovation and Biomedical Research on Light and Image, Coimbra, Portugal
| | - Edoardo Midena
- Department of Ophthalmology, University of Padova, Padua, Italy.
- IRCCS Fondazione Bietti, Rome, Italy.
| |
Collapse
|
4
|
Crossland MD, Dekker TM, Dahlmann-Noor A, Jones PR. Can children measure their own vision? A comparison of three new contrast sensitivity tests. Ophthalmic Physiol Opt 2024; 44:5-16. [PMID: 37728235 DOI: 10.1111/opo.13230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 08/23/2023] [Accepted: 08/24/2023] [Indexed: 09/21/2023]
Abstract
PURPOSE To investigate the feasibility of children measuring their own contrast sensitivity using a range of tablet- and paper-based tests. METHODS Forty children aged 5-15 years with amblyopia (N = 10), bilateral vision impairment (N = 10) or good vision (N = 20) measured their own vision on a screen-based optotype test (Manifold), a gamified vision test (PopCSF) and a paper-based test (Spotchecks) in a laboratory with minimal supervision. Completion rate, test-retest repeatability, test duration and participants' preferences were recorded for each test. RESULTS Most participants (36/40) were able to perform all three tests. All tests were correlated with clinically measured visual acuity and contrast sensitivity (p < 0.001). The 95% coefficient of repeatability was 0.30 dB for Manifold, 0.29 dB for PopCSF and 0.13 dB for Spotchecks. All tests differentiated between children with reduced contrast sensitivity and control participants. PopCSF and Spotchecks were also able to differentiate between children with amblyopia and those with good vision. Median test time was 152, 130 and 202 s for Manifold, PopCSF and Spotchecks, respectively. Twenty-two participants preferred the PopCSF test, 10 preferred Spotchecks and 6 preferred Manifold. Thirty-nine out of the 40 children (98%) said they would measure their own vision at home using at least one of these tests every month. CONCLUSIONS Children and young people can test their own contrast sensitivity with repeatable results. Of these three tests, the most repeatable was Spotchecks, the quickest was PopCSF and participants' favourite was PopCSF. Nearly all of the participants said they would be willing to use at least one of the three tests at home.
Collapse
Affiliation(s)
- Michael D Crossland
- NIHR Moorfields Biomedical Research Centre, London, UK
- UCL Institute of Ophthalmology, London, UK
| | - Tessa M Dekker
- NIHR Moorfields Biomedical Research Centre, London, UK
- UCL Institute of Ophthalmology, London, UK
| | - Annegret Dahlmann-Noor
- NIHR Moorfields Biomedical Research Centre, London, UK
- UCL Institute of Ophthalmology, London, UK
| | - Pete R Jones
- UCL Institute of Ophthalmology, London, UK
- Department of Optometry and Visual sciences, City, University of London, London, UK
| |
Collapse
|
5
|
Dieke S, Wurche S, Ruebsam A, Wirbelauer C, Joussen AM, Winterhalter S. Impact of intravitreal injection therapy on contrast sensitivity in patients with nAMD and DME. Graefes Arch Clin Exp Ophthalmol 2023; 261:1823-1833. [PMID: 36622409 PMCID: PMC10272247 DOI: 10.1007/s00417-022-05944-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 11/15/2022] [Accepted: 11/26/2022] [Indexed: 01/10/2023] Open
Abstract
PURPOSE The study aims to evaluate changes in contrast sensitivity (CS) during therapy with intravitreal vascular endothelial growth factor (VEGF) inhibitors in patients with neovascular age-related macular degeneration (nAMD) and diabetic macular edema (DME). METHODS Prospective, uncontrolled, multicenter study on patients with neovascular AMD or DME who underwent intravitreal injection therapy with Ranibizumab, Aflibercept, or Bevacizumab was conducted. Best corrected visual acuity (BCVA) and CS measured by Mars Letter Contrast Sensitivity Test (MLCS) and Freiburg Visual Acuity and Contrast Test (FrACT) in logCS were evaluated before 3 consecutive VEGF inhibitor injections, which followed the pro renata regimen in treatment-naïve and pretreated eyes with a maximum of 9 injections. Correlation of MLCS and FrACT was calculated by the Spearman's rank correlation coefficient. RESULTS Eighty eyes of 74 patients (mean age 72.7; SD ± 9.96) were included. BCVA improved significantly from 0.44 (SD ± 0.21) logMAR to 0.38 (SD ± 0.23) logMAR by 0.06 (SD ± 0.14) logMAR values (p < 0.001). CS measured by MLCS increased significantly from 1.27 (SD ± 0.25) logCS to 1.39 (SD ± 0.22) logCS (p < 0.001). CS measured by FrACT also improved significantly from 1.22 (SD ± 0.32) logCS to 1.30 (SD ± 0.29) logCS (p = 0.035). A positive correlation between MLCS and FrACT was found (r = 0.389; p < 0.001). Despite statistical significance, results for BCVA, MLCS, and FrACT failed clinical significance. Overall best test results were achieved with MLCS. CONCLUSIONS Intravitreal injection therapy with VEGF inhibitors led to an improvement of BCVA and CS measured by MLCS and FrACT. MLCS was superior and more sensitive compared to FrACT and even BCVA to evaluate CS in elderly patients with macular pathology.
Collapse
Affiliation(s)
- Sebastian Dieke
- Beuth Hochschule for Technology Berlin, University of Applied Sciences, Berlin, Germany
| | - Stefanie Wurche
- Beuth Hochschule for Technology Berlin, University of Applied Sciences, Berlin, Germany
| | - Anne Ruebsam
- Department of Ophthalmology, Charité-University Medicine Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany
- Berlin Institute of Health (BIH), Berlin, Germany
| | | | - Antonia M Joussen
- Department of Ophthalmology, Charité-University Medicine Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany
- Berlin Institute of Health (BIH), Berlin, Germany
| | - Sibylle Winterhalter
- Department of Ophthalmology, Charité-University Medicine Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany.
| |
Collapse
|
6
|
Ye Y, Xian Y, Liu F, Lu ZL, Zhou X, Zhao J. Characteristics and Related Parameters of Quick Contrast Sensitivity Function in Chinese Ametropia Children. Eye Contact Lens 2023; 49:224-233. [PMID: 37126017 PMCID: PMC10194057 DOI: 10.1097/icl.0000000000000995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/21/2023] [Indexed: 05/02/2023]
Abstract
PURPOSE To investigate the characteristics of quick contrast sensitivity function (qCSF) and its related parameters in Chinese ametropia children. METHODS This case series study enrolled 106 eyes of 53 children (male/female=29/24, age: 9.04±2.06 years). Examinations included manifest refraction, axial length, corneal curvature, and monocular and binocular qCSF readings without refractive correction (area under log CSF [AULCSF], CSF acuity, and contrast sensitivity [CS] at 1.0 to 18.0 cpd). The subjects were divided into groups according to age and refractive parameters for analysis. RESULTS The mean spherical equivalent (SE), AULCSF, and CSF acuity of the test eyes were -0.94±1.53 D, 0.44±0.33, and 8.50±5.97 cpd, respectively. In the monocular qCSF comparison, the refraction sphere (RS) was the major factor correlated with qCSF readings (B=0.186, P =0.009 for AULCSF; B=0.543, P =0.019 for CSF acuity; generalized linear model). The three groups stratified by RS/SE (<-1.00D, -1.00D to 0D, and >0D) showed significant differences in CS at medium spatial frequencies (3.0 and 6.0 cpd; all P <0.05). In the low RS/SE group (within -1 to 0 D), the CS at 12.0 cpd was significantly lower than that in the hyperopia group (all P <0.05). Binocular qCSF readings were significantly correlated with those of the eyes with lower RS (all P <0.05). CONCLUSION RS and SE are the major contributing factors of qCSF without refractive correction in children. The CS at medium spatial frequencies decrease significantly as the RS/SE increase. In low myopia children, the CS at medium and high spatial frequencies are significantly decreased, providing practical value in visual function screening in children.
Collapse
Affiliation(s)
- Yuhao Ye
- Department of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia (Fudan University) (Y.Y., Y.X., F.L., X.Z., J.Z.), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China; Shanghai Research Center of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Shanghai, China; Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000) (Y.Y., Y.X., F.L., X.Z., J.Z.)Division of Arts and Sciences (Z.-L.L.), NYU Shanghai, Shanghai, China; Center for Neural Science and Department of Psychology, New York University, New York; NYU-ECNU Institute of Brain and Cognitive Science, NYU Shanghai, Shanghai, China
| | - Yiyong Xian
- Department of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia (Fudan University) (Y.Y., Y.X., F.L., X.Z., J.Z.), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China; Shanghai Research Center of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Shanghai, China; Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000) (Y.Y., Y.X., F.L., X.Z., J.Z.)Division of Arts and Sciences (Z.-L.L.), NYU Shanghai, Shanghai, China; Center for Neural Science and Department of Psychology, New York University, New York; NYU-ECNU Institute of Brain and Cognitive Science, NYU Shanghai, Shanghai, China
| | - Fang Liu
- Department of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia (Fudan University) (Y.Y., Y.X., F.L., X.Z., J.Z.), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China; Shanghai Research Center of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Shanghai, China; Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000) (Y.Y., Y.X., F.L., X.Z., J.Z.)Division of Arts and Sciences (Z.-L.L.), NYU Shanghai, Shanghai, China; Center for Neural Science and Department of Psychology, New York University, New York; NYU-ECNU Institute of Brain and Cognitive Science, NYU Shanghai, Shanghai, China
| | - Zhong-Lin Lu
- Department of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia (Fudan University) (Y.Y., Y.X., F.L., X.Z., J.Z.), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China; Shanghai Research Center of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Shanghai, China; Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000) (Y.Y., Y.X., F.L., X.Z., J.Z.)Division of Arts and Sciences (Z.-L.L.), NYU Shanghai, Shanghai, China; Center for Neural Science and Department of Psychology, New York University, New York; NYU-ECNU Institute of Brain and Cognitive Science, NYU Shanghai, Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia (Fudan University) (Y.Y., Y.X., F.L., X.Z., J.Z.), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China; Shanghai Research Center of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Shanghai, China; Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000) (Y.Y., Y.X., F.L., X.Z., J.Z.)Division of Arts and Sciences (Z.-L.L.), NYU Shanghai, Shanghai, China; Center for Neural Science and Department of Psychology, New York University, New York; NYU-ECNU Institute of Brain and Cognitive Science, NYU Shanghai, Shanghai, China
| | - Jing Zhao
- Department of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia (Fudan University) (Y.Y., Y.X., F.L., X.Z., J.Z.), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China; Shanghai Research Center of Ophthalmology and Optometry (Y.Y., Y.X., F.L., X.Z., J.Z.), Shanghai, China; Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000) (Y.Y., Y.X., F.L., X.Z., J.Z.)Division of Arts and Sciences (Z.-L.L.), NYU Shanghai, Shanghai, China; Center for Neural Science and Department of Psychology, New York University, New York; NYU-ECNU Institute of Brain and Cognitive Science, NYU Shanghai, Shanghai, China
| |
Collapse
|
7
|
Cedro L, Hoffmann L, Hatz K. Geographic Atrophy in AMD: Prognostic Factors Based on Long-Term Follow-Up. Ophthalmic Res 2023; 66:791-800. [PMID: 37231906 PMCID: PMC10308554 DOI: 10.1159/000530418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Accepted: 03/06/2023] [Indexed: 05/27/2023]
Abstract
INTRODUCTION The aim of this large-scale long-term retrospective study was to show the enlargement rate (ER) of geographic atrophy (GA) in age-related macular degeneration (AMD), defined as complete retinal pigment epithelium and outer retinal atrophy (cRORA), to find predictors of progression in a clinical routine setting and to compare GA evaluation methods. METHODS All patients available in our database with follow-up of at least 24 months and cRORA in at least one eye, regardless of neovascular AMD being present, were included. SD-OCT and fundus autofluorescence (FAF) evaluations were performed according to a standardized protocol. The cRORA area ER, the cRORA square root area ER, the FAF GA area, and the condition of the outer retina (inner-/outer-segment [IS/OS] line and external limiting membrane [ELM] disruption scores) were determined. RESULTS 204 eyes of 129 patients were included. Mean follow-up time was 4.2 ± 2.2 (range 2-10) years. 109 of 204 (53.4%) eyes were classified as MNV-associated GA in AMD (initially or during follow-up); 95 of 204 (46.6%) eyes were classified as pure GA in AMD. The primary lesion was unifocal in 146 (72%) eyes and multifocal in 58 (28%) eyes. A strong correlation was observed between the area of cRORA (SD-OCT) and the FAF GA area (r = 0.924; p < 0.001). Mean ER was 1.44 ± 1.2 mm2/year, mean square root ER 0.29 ± 0.19 mm/year. There was no significant difference in mean ER between eyes without (pure GA) and with intravitreal anti-VEGF injections (MNV-associated GA) (0.30 ± 0.19 mm/year vs. 0.28 ± 0.20 mm/year; p = 0.466). Eyes with multifocal atrophy pattern at baseline had a significantly higher mean ER compared to eyes with unifocal pattern (0.34 ± 0.19 mm/year vs. 0.27 ± 1.19 mm/year; p = 0.008). There were moderate significant correlations between ELM and IS/OS disruption scores and visual acuity at baseline, 5 and 7 years (all r values ca. -0.5; p < 0.001). In multivariate regression analysis, a multifocal cRORA pattern at baseline (p = 0.022) and a smaller baseline lesion size (p = 0.036) were associated with a higher mean ER. CONCLUSION SD-OCT-evaluated cRORA area might serve as a GA parameter comparable to traditional FAF measurement in clinical routine. The dispersion pattern and baseline lesion size might be predictors of ER, whereas anti-VEGF treatment seems not to be associated with ER.
Collapse
Affiliation(s)
- Luca Cedro
- Vista Augenklinik Binningen, Binningen, Switzerland
| | - Laura Hoffmann
- Vista Augenklinik Binningen, Binningen, Switzerland
- Department of Ophthalmology, Charité Universitätsmedizin Berlin, Campus Benjamin Franklin, Berlin, Germany
| | - Katja Hatz
- Vista Augenklinik Binningen, Binningen, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| |
Collapse
|
8
|
Murakami T, Okamoto F, Sugiura Y, Morikawa S, Okamoto Y, Hiraoka T, Oshika T. Contrast sensitivity and quality of life following intravitreal ranibizumab injection for central retinal vein occlusion. Br J Ophthalmol 2023; 107:254-260. [PMID: 34452939 DOI: 10.1136/bjophthalmol-2021-319863] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 08/17/2021] [Indexed: 01/27/2023]
Abstract
SYNOPSIS/PRECIS We investigated the relationship between contrast sensitivity (CS) and vision-related quality of life (VR-QOL) in patients with central retinal vein occlusion following ranibizumab intravitreal injection; CS showed a stronger association with VR-QOL than visual acuity. BACKGROUND/AIMS To investigate the relationship between CS, VR-QOL and optical coherence tomography (OCT) findings in patients with cystoid macular oedema secondary to central retinal vein occlusion (CRVO-CMO) following intravitreal injection of ranibizumab. METHODS This was a multicentre, open-label, single-arm, prospective study. The study included 23 patients with CRVO-CMO who were followed up for 12 months after treatment. The best-corrected visual acuity (BCVA), letter contrast sensitivity (LCS) and OCT images were obtained every month. For VR-QOL assessment, the 25-item National Eye Institute Visual Function Questionnaire (VFQ-25) was administered to the patients before treatment and at 3, 6 and 12 months following treatment. RESULTS The LCS and VFQ-25 composite score improved significantly from baseline to 12 months following treatment. The multiple regression analysis revealed that the LCS of the affected eye and BCVA of the fellow eye were related to the VFQ-25 composite score following treatment. The LCS improvement showed a significant correlation with the improvement in the VFQ-25 composite score, whereas the BCVA improvement was not correlated with the improvement in the VFQ-25 composite score. Stepwise multiple regression analyses revealed that, at the time of macular oedema resolution, the distance between the external limiting membrane and retinal pigment epithelium (ELM-RPE) and average ganglion cell-inner plexiform layer (GCIPL) thickness were associated with LCS. CONCLUSION CS had a stronger association with VR-QOL than with BCVA in patients with CRVO-CMO. With the resolution of macular oedema, CS was associated with ELM-RPE thickness and average GCIPL thickness.
Collapse
Affiliation(s)
- Tomoya Murakami
- Department of Ophthalmology, University of Tsukuba Faculty of Medicine, Tsukuba, Ibaraki, Japan
| | - Fumiki Okamoto
- Department of Ophthalmology, University of Tsukuba Faculty of Medicine, Tsukuba, Ibaraki, Japan
| | - Yoshimi Sugiura
- Department of Ophthalmology, University of Tsukuba Faculty of Medicine, Tsukuba, Ibaraki, Japan
| | - Shohei Morikawa
- Department of Ophthalmology, University of Tsukuba Faculty of Medicine, Tsukuba, Ibaraki, Japan
| | - Yoshifumi Okamoto
- Department of Ophthalmology, University of Tsukuba Faculty of Medicine, Tsukuba, Ibaraki, Japan.,Department of Ophthalmology, Mito Kyodo General Hospital, Mito, Ibaraki, Japan
| | - Takahiro Hiraoka
- Department of Ophthalmology, University of Tsukuba Faculty of Medicine, Tsukuba, Ibaraki, Japan
| | - Tetsuro Oshika
- Department of Ophthalmology, University of Tsukuba Faculty of Medicine, Tsukuba, Ibaraki, Japan
| |
Collapse
|
9
|
Almaliotis D, Athanasopoulos GP, Almpanidou S, Papadopoulou EP, Karampatakis V. Design and Validation of a New Smartphone-Based Reading Speed App (GDRS-Test) for the Greek Speaking Population. CLINICAL OPTOMETRY 2022; 14:111-124. [PMID: 35942276 PMCID: PMC9356703 DOI: 10.2147/opto.s370215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 07/17/2022] [Indexed: 06/15/2023]
Abstract
PURPOSE To present a novel smartphone-based application (GDRS-test, Greek Digital Reading Speed - test) for the assessment of reading speed, to evaluate, whether this test could be easily and reliably used by patients with visual impairment and normal individuals serving as an adjunctive tool for their visual examination. PATIENTS AND METHODS One hundred and five visually impaired and 32 normal eyes were examined. Depending on existing active ocular pathology, patients were divided into a non-macular and a macular group, We examined the reading performance for continuous text (MNREAD chart) and random unrelated words of the new smartphone-based reading speed app, monocularly. The patients' best-corrected visual acuity ranged from 1.3 to 0.2 logMAR. Examinees were asked to read aloud (at a 40 cm distance) a series of 30 random two-syllable and then 30 three-syllable Greek words, without semantic connection. Reading speed was measured as correct words per minute for critical print size. The individuals were examined twice within 2 weeks for test-retest reliability. Correlations and comparisons concerning each group adjusted for age and visual acuity were performed. RESULTS There was moderate correlation between MNREAD and 2SYL SPEED (Reading speed for 2-syllable) (Pearson's rho = 0.589, p < 0.001) and 3SYL SPEED (Reading speed for 3-syllable) (Pearson's rho = 0.617, p < 0.001) for healthy individuals. The mean 2SYL SPEED and 3SYL SPEED for Individuals of the maculopathies group or non-maculopathies group were significantly lower compared to normal individuals adjusted for age and visual acuity [B (95% CI): -93.077 (-104.165, -81.98), p < 0.001] and [B (95% CI): -92.254 (-104.196, -80.312), p < 0.001], respectively. The test-retest analysis showed a good agreement for patients and healthy individuals. CONCLUSION The novel-reading speed application for the Greek-speaking population was found to accurately detect differences between patients with visual impairment and healthy individuals. It was designed and constructed with the intention to ease and improve the ophthalmic examination allowing individuals to self-evaluate reading speed by transmitting the result to their physician.
Collapse
Affiliation(s)
- Diamantis Almaliotis
- Laboratory of Experimental Ophthalmology, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Georgios P Athanasopoulos
- Laboratory of Experimental Ophthalmology, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Stavroula Almpanidou
- Laboratory of Experimental Ophthalmology, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Eleni P Papadopoulou
- Laboratory of Experimental Ophthalmology, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Vasileios Karampatakis
- Laboratory of Experimental Ophthalmology, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
10
|
Altinbay D, Sahli E, Idil A. Comparison of Two Different Contrast Sensitivity Testing Methods in Patients with Low Vision. J Curr Ophthalmol 2022; 34:60-66. [PMID: 35620371 PMCID: PMC9128427 DOI: 10.4103/joco.joco_147_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 09/02/2021] [Accepted: 09/04/2021] [Indexed: 11/22/2022] Open
Abstract
Purpose: To assess the agreement between two different contrast testing modalities using the index of contrast sensitivity (ICS) in patients with low vision. Methods: Thirty-eight patients with low vision were included in the study. Contrast sensitivity (CS) was measured binocularly with both the Vector vision-standardized CS test (CSV-1000E, Vector Vision Co, Greenville, Ohio, USA) and the MonPack 3 (Metrovision, France) after refractive correction for each participant. Based on the data from the two tests, the ICS was calculated. The Bland–Altman technique was used to evaluate the agreement between ICSs obtained from different test methods. Results: Range of best corrected visual acuity was 0.50–1.00 logMAR. According to the median logCS values, CS values were highest at 3 cycles per degree (cpd) for the CSV-1000E test and at 1.5 cpd for the Metrovision MonPack 3 test. The median ICS for CSV-1000E was −0.22 (95th percentile 4.75), and the median ICS for Metrovision MonPack 3 was 0.08 (95th percentile 1.65). The mean difference was 0.655 (between −3.82 and 5.13) within limits of agreement (LoA). The difference and mean values between the two CS test measurements were found to be within LoA range. Conclusions: An agreement was found between the Metrovision MonPack 3 test and the standard CSV-1000E test results in patients with visual impairment. However, the agreement range was within very wide limits. Therefore, it was thought that they may not be used interchangeability in clinical practice.
Collapse
Affiliation(s)
- Deniz Altinbay
- Özel Niv Eye Center, Adana, Turkey.,Vision Studies and Low Vision Rehabilitation Unit, Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey.,Ankara University Graduate School of Health Sciences, Ankara, Turkey
| | - Esra Sahli
- Vision Studies and Low Vision Rehabilitation Unit, Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey.,Ankara University Graduate School of Health Sciences, Ankara, Turkey
| | - Aysun Idil
- Vision Studies and Low Vision Rehabilitation Unit, Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
11
|
Sverdlichenko I, Mandelcorn MS, Issashar Leibovitzh G, Mandelcorn ED, Markowitz SN, Tarita-Nistor L. Binocular visual function and fixational control in patients with macular disease: A review. Ophthalmic Physiol Opt 2021; 42:258-271. [PMID: 34862635 PMCID: PMC9299778 DOI: 10.1111/opo.12925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 10/29/2021] [Accepted: 10/31/2021] [Indexed: 11/24/2022]
Abstract
For normally sighted observers, the centre of the macula—the fovea—provides the sharpest vision and serves as the reference point for the oculomotor system. Typically, healthy observers have precise oculomotor control and binocular visual performance that is superior to monocular performance. These functions are disturbed in patients with macular disease who lose foveal vision. An adaptation to central vision loss is the development of a preferred retinal locus (PRL) in the functional eccentric retina, which is determined with a fixation task during monocular viewing. Macular disease often affects the two eyes unequally, but its impact on binocular function and fixational control is poorly understood. Given that patients’ natural viewing condition is binocular, the aim of this article was to review current research on binocular visual function and fixational oculomotor control in macular disease. Our findings reveal that there is no overall binocular gain across a range of visual functions, although clear evidence exists for subgroups of patients who exhibit binocular summation or binocular inhibition, depending on the clinical characteristics of their two eyes. The monocular PRL of the better eye has different characteristics from that of the worse eye, but during binocular viewing the PRL of the better eye drives fixational control and may serve as the new reference position for the oculomotor system. We conclude that evaluating binocular function in patients with macular disease reveals important clinical aspects that otherwise cannot be determined solely from examining monocular functions, and can lead to better disease management and interventions.
Collapse
Affiliation(s)
| | - Mark S Mandelcorn
- Krembil Research Institute, Donald K Johnson Eye Institute, University Health Network, Toronto, Ontario, Canada.,Department of Ophthalmology and Vision Sciences, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Galia Issashar Leibovitzh
- Krembil Research Institute, Donald K Johnson Eye Institute, University Health Network, Toronto, Ontario, Canada
| | - Efrem D Mandelcorn
- Krembil Research Institute, Donald K Johnson Eye Institute, University Health Network, Toronto, Ontario, Canada.,Department of Ophthalmology and Vision Sciences, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Samuel N Markowitz
- Krembil Research Institute, Donald K Johnson Eye Institute, University Health Network, Toronto, Ontario, Canada.,Department of Ophthalmology and Vision Sciences, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Luminita Tarita-Nistor
- Krembil Research Institute, Donald K Johnson Eye Institute, University Health Network, Toronto, Ontario, Canada
| |
Collapse
|
12
|
Switching to Brolucizumab in Neovascular Age-Related Macular Degeneration Incompletely Responsive to Ranibizumab or Aflibercept: Real-Life 6 Month Outcomes. J Clin Med 2021; 10:jcm10122666. [PMID: 34204266 PMCID: PMC8235134 DOI: 10.3390/jcm10122666] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 06/03/2021] [Accepted: 06/11/2021] [Indexed: 11/16/2022] Open
Abstract
Purpose: The aim of this study was to evaluate the effect of switching treatment in eyes with neovascular age-related macular degeneration (nAMD) and treatment intervals of ≤6 weeks to brolucizumab. Methods: In this prospective series, eyes with persisting retinal fluid under aflibercept or ranibizumab every 4–6 weeks were switched to brolucizumab. Visual acuity (BCVA), reading acuity (RA), treatment intervals, central subfield thickness (CST), and the presence of intra- and subretinal fluid were recorded over 6 months. Results: Seven of 12 eyes completed the 6 month follow-up and received 4.4 ± 0.5 brolucizumab injections within 28.0 ± 2.8 weeks. Treatment intervals increased from 5.3 ± 0.9 weeks to 9.0 ± 2.8 weeks (95% confidence interval of extension (CI): 1.6 to 5.9). BCVA improved from 67.8 ± 7.2 to 72.2 ± 7.5 (95% CI: −0.3 to 9.1) ETDRS letters, RA improved from 0.48 ± 0.15 to 0.31 ± 0.17 LogRAD (95% CI: 0.03 to 0.25), and CST improved from 422.1 ± 97.3 to 353.6 ± 100.9 µm (95% CI: −19.9 to 157.1). Treatment was terminated early in five eyes (two intraocular inflammations with vascular occlusion without vision loss, one stroke, and two changes in the treatment plan). Conclusions: Improvement in visual performance and longer treatment intervals in our series over 6 months indicate the potential of brolucizumab to reduce the treatment burden in nAMD, while two instances of intraocular inflammation were encountered.
Collapse
|
13
|
Hoffmann L, Rossouw P, Guichard MM, Hatz K. Strongest Correlation Between Contrast Sensitivity and Morphological Characteristics in Bilateral nAMD. Front Med (Lausanne) 2021; 7:622877. [PMID: 33585517 PMCID: PMC7876058 DOI: 10.3389/fmed.2020.622877] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 12/30/2020] [Indexed: 11/13/2022] Open
Abstract
In patients with neovascular age-related macular degeneration (nAMD) there is often an inconsistency between their subjective visual impairment and a still relatively preserved standard Early Treatment of Diabetic Retinopathy Study (ETDRS) best corrected visual acuity. Therefore, in order to better capture the specific functional defects in nAMD, other tests need to be evaluated. In a previous study, we reported contrast sensitivity of the better eye to best correlate with near distance and distance vision related quality of life in patients with bilateral nAMD. Here, we evaluated Pelli-Robson contrast sensitivity, ETDRS visual acuity, low luminance visual acuity and Radner maximum reading speed and correlated them with several morphologic parameters as measured on fundus autofluorescence imaging, optical coherence tomography and optical tomography angiography in 54 patients. A multiple regression analysis was performed which correlated each visual function parameter with the anatomic features. The results showed the strongest correlations between the total area of macular geographic atrophy as well as the percentage of geographic atrophy in the central 1 mm and contrast sensitivity. Further, the regression model selected the total area of macular geographic atrophy, the photoreceptor inner and outer segments interface disruption score, the presence of subretinal fibrosis in the central 1 mm and the central retinal thickness as the variables that explained 71% of the variation in contrast sensitivity when including all eyes. Hence, our results suggest that among the evaluated measures of vision, contrast sensitivity is best correlated with the morphologic impairment in bilateral nAMD. Thus, contrast sensitivity may complement ETDRS visual acuity in clinical trials and serve as a standard diagnostic tool in clinical practice.
Collapse
Affiliation(s)
| | - Petra Rossouw
- Vista Klinik, Binningen, Switzerland.,Department of Vision Science and Optometry, University of Aalen, Aalen, Germany
| | | | - Katja Hatz
- Vista Klinik, Binningen, Switzerland.,Faculty of Medicine, University of Basel, Basel, Switzerland
| |
Collapse
|
14
|
Rossouw P, Guichard MM, Hatz K. Contrast sensitivity and binocular reading speed best correlating with near distance vision-related quality of life in bilateral nAMD. Ophthalmic Physiol Opt 2020; 40:760-769. [PMID: 32959926 PMCID: PMC7702040 DOI: 10.1111/opo.12736] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 08/17/2020] [Accepted: 08/17/2020] [Indexed: 01/14/2023]
Abstract
Purpose Bilateral neovascular age‐related macular degeneration (nAMD) causes difficulties in daily life, especially with regard to near‐vision tasks, despite well preserved Early Treatment of Diabetic Retinopathy Study (ETDRS) best corrected visual acuity (BCVA) at distance. Therefore, alternative visual function measures were evaluated in terms of their correlation with vision‐related quality of life scores (QoL). Methods A prospective cross‐sectional pilot study including patients with a diagnosis of bilateral nAMD having lesions within the central 1 mm ETDRS grid subfield. Standardised testing included a vision‐related QoL assessment (NEI‐VFQ25), best corrected visual acuity (BCVA), low luminance visual acuity (LLVA), Radner maximum reading speed and Pelli‐Robson contrast sensitivity (CS). Results N = 54. The mean better eye (range) BCVA was 79 (55–96) letters, median (range) LLVA 79.5 (58–97) letters and median (range) CS 1.35 (0–1.65) log units. Mean binocular maximum reading speed was 117.33 ± 28.42 wpm. The best correlations with the near subscale score were found for CS followed by binocular maximum reading speed (r = 0.59, p = 0.0001; r = 0.36, p = 0.008, respectively). A weaker correlation was observed for the BCVA in the better eye (r = 0.33, p = 0.02). The correlation between the NEI‐VFQ25 distance subscale and BCVA was weaker (r = 0.37, p = 0.005) than the correlations with CS (r = 0.67, p = 0.0001) and LLVA (r = 0.40, p = 0.003). Conclusions For patients with a bilateral centre‐involving nAMD, the best correlation with near QoL was the better eye CS followed by maximum binocular reading speed. These measures could be valuable in quantifying vision‐related QoL outcomes in AMD clinical trials.
Collapse
Affiliation(s)
- Petra Rossouw
- Department of Vision Science and Optometry, University of Aalen, Aalen, Germany.,Vista Klinik Binningen, Binningen, Switzerland
| | | | - Katja Hatz
- Vista Klinik Binningen, Binningen, Switzerland.,Faculty of Medicine, University of Basel, Basel, Switzerland
| |
Collapse
|