1
|
Bertram CD. The Lymphatic Vascular System: Does Nonuniform Lymphangion Length Limit Flow-Rate? J Biomech Eng 2024; 146:091007. [PMID: 38558115 PMCID: PMC11080954 DOI: 10.1115/1.4065217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 03/25/2024] [Accepted: 03/26/2024] [Indexed: 04/04/2024]
Abstract
A previously developed model of a lymphatic vessel as a chain of lymphangions was investigated to determine whether lymphangions of unequal length reduce pumping relative to a similar chain of equal-length ones. The model incorporates passive elastic and active contractile properties taken from ex vivo measurements, and intravascular lymphatic valves as transvalvular pressure-dependent resistances to flow with hysteresis and transmural pressure-dependent bias to the open state as observed experimentally. Coordination of lymphangion contractions is managed by marrying an autonomous transmural pressure-dependent pacemaker for each lymphangion with bidirectional transmission of activation signals between lymphangions, qualitatively matching empirical observations. With eight lymphangions as used here and many nonlinear constraints, the model is capable of complex outcomes. The expected flow-rate advantage conferred by longer lymphangions everywhere was confirmed. However, the anticipated advantage of uniform lymphangions over those of unequal length, compared in chains of equal overall length, was not found. A wide variety of dynamical outcomes was observed, with the most powerful determinant being the adverse pressure difference, rather than the arrangement of long and short lymphangions. This work suggests that the wide variation in lymphangion length which is commonly observed in collecting lymphatic vessels does not confer disadvantage in pumping lymph.
Collapse
Affiliation(s)
- C. D. Bertram
- School of Mathematics and Statistics, University of Sydney, Sydney, New South Wales 2006, Australia
| |
Collapse
|
2
|
Davis MJ, Zawieja SD. Pacemaking in the lymphatic system. J Physiol 2024. [PMID: 38520402 DOI: 10.1113/jp284752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 02/08/2024] [Indexed: 03/25/2024] Open
Abstract
Lymphatic collecting vessels exhibit spontaneous phasic contractions that are critical for lymph propulsion and tissue fluid homeostasis. This rhythmic activity is driven by action potentials conducted across the lymphatic muscle cell (LMC) layer to produce entrained contractions. The contraction frequency of a lymphatic collecting vessel displays exquisite mechanosensitivity, with a dynamic range from <1 to >20 contractions per minute. A myogenic pacemaker mechanism intrinsic to the LMCs was initially postulated to account for pressure-dependent chronotropy. Further interrogation into the cellular constituents of the lymphatic vessel wall identified non-muscle cell populations that shared some characteristics with interstitial cells of Cajal, which have pacemaker functions in the gastrointestinal and lower urinary tracts, thus raising the possibility of a non-muscle cell pacemaker. However, recent genetic knockout studies in mice support LMCs and a myogenic origin of the pacemaker activity. LMCs exhibit stochastic, but pressure-sensitive, sarcoplasmic reticulum calcium release (puffs and waves) from IP3R1 receptors, which couple to the calcium-activated chloride channel Anoctamin 1, causing depolarisation. The resulting electrical activity integrates across the highly coupled lymphatic muscle electrical syncytia through connexin 45 to modulate diastolic depolarisation. However, multiple other cation channels may also contribute to the ionic pacemaking cycle. Upon reaching threshold, a voltage-gated calcium channel-dependent action potential fires, resulting in a nearly synchronous calcium global calcium flash within the LMC layer to drive an entrained contraction. This review summarizes the key ion channels potentially responsible for the pressure-dependent chronotropy of lymphatic collecting vessels and various mechanisms of IP3R1 regulation that could contribute to frequency tuning.
Collapse
Affiliation(s)
- Michael J Davis
- Department of Medical Pharmacology and Physiology, University of Missouri School of Medicine, Columbia, MO, USA
| | - Scott D Zawieja
- Department of Medical Pharmacology and Physiology, University of Missouri School of Medicine, Columbia, MO, USA
| |
Collapse
|
3
|
Sedaghati F, Dixon JB, Gleason RL. A 1D model characterizing the role of spatiotemporal contraction distributions on lymph transport. Sci Rep 2023; 13:21241. [PMID: 38040740 PMCID: PMC10692214 DOI: 10.1038/s41598-023-48131-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 11/22/2023] [Indexed: 12/03/2023] Open
Abstract
Lymphedema is a condition in which lymph transport is compromised. The factors that govern the timing of lymphatic contractions are largely unknown; however, these factors likely play a central role in lymphatic health. Computational models have proven useful in quantifying changes in lymph transport; nevertheless, there is still much unknown regarding the regulation of contractions. The purpose of this paper is to utilize computational modeling to examine the role of pacemaking activity in lymph transport. A 1D fluid-solid modeling framework was utilized to describe the interaction between the contracting vessel and the lymph flow. The distribution of contractions along a three-lymphangion chain in time and space was determined by specifying the pacemaking sites and parameters obtained from experimentation. The model effectively replicates the contractility patterns in experiments. Quantitatively, the flow rates were measured at 5.44 and 2.29 [Formula: see text], and the EF values were 78% and less than 33% in the WT and KO models, respectively, which are consistent with the literature. Applying pacemaking parameters in this modeling framework effectively captures lymphatic contractile wave propagations and their relation to lymph transport. It can serve as a motivation for conducting novel studies to evaluate lymphatic pumping function during the development of lymphedema.
Collapse
Affiliation(s)
- Farbod Sedaghati
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - J Brandon Dixon
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
- The Wallace H. Coulter Georgia Tech/Emory Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Rudolph L Gleason
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
- The Wallace H. Coulter Georgia Tech/Emory Department of Biomedical Engineering, Georgia Institute of Technology, 387 Technology Circle, Room 216F, Atlanta, GA, 30313, USA.
| |
Collapse
|
4
|
Breslin JW. Lymphatic Clearance and Pump Function. Cold Spring Harb Perspect Med 2023; 13:cshperspect.a041187. [PMID: 35667711 PMCID: PMC9899645 DOI: 10.1101/cshperspect.a041187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Lymphatic vessels have an active role in draining excess interstitial fluid from organs and serving as conduits for immune cell trafficking to lymph nodes. In the central circulation, the force needed to propel blood forward is generated by the heart. In contrast, lymphatic vessels rely on intrinsic vessel contractions in combination with extrinsic forces for lymph propulsion. The intrinsic pumping features phasic contractions generated by lymphatic smooth muscle. Periodic, bicuspid valves composed of endothelial cells prevent backflow of lymph. This work provides a brief overview of lymph transport, including initial lymph formation along with cellular and molecular mechanisms controlling lymphatic vessel pumping.
Collapse
Affiliation(s)
- Jerome W Breslin
- Department of Molecular Pharmacology and Physiology, Morsani College of Medicine, University of South Florida, Tampa, Florida 33612, USA
| |
Collapse
|
5
|
Lee Y, Zawieja SD, Muthuchamy M. Lymphatic Collecting Vessel: New Perspectives on Mechanisms of Contractile Regulation and Potential Lymphatic Contractile Pathways to Target in Obesity and Metabolic Diseases. Front Pharmacol 2022; 13:848088. [PMID: 35355722 PMCID: PMC8959455 DOI: 10.3389/fphar.2022.848088] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 02/17/2022] [Indexed: 01/19/2023] Open
Abstract
Obesity and metabolic syndrome pose a significant risk for developing cardiovascular disease and remain a critical healthcare challenge. Given the lymphatic system's role as a nexus for lipid absorption, immune cell trafficking, interstitial fluid and macromolecule homeostasis maintenance, the impact of obesity and metabolic disease on lymphatic function is a burgeoning field in lymphatic research. Work over the past decade has progressed from the association of an obese phenotype with Prox1 haploinsufficiency and the identification of obesity as a risk factor for lymphedema to consistent findings of lymphatic collecting vessel dysfunction across multiple metabolic disease models and organisms and characterization of obesity-induced lymphedema in the morbidly obese. Critically, recent findings have suggested that restoration of lymphatic function can also ameliorate obesity and insulin resistance, positing lymphatic targeted therapies as relevant pharmacological interventions. There remain, however, significant gaps in our understanding of lymphatic collecting vessel function, particularly the mechanisms that regulate the spontaneous contractile activity required for active lymph propulsion and lymph return in humans. In this article, we will review the current findings on lymphatic architecture and collecting vessel function, including recent advances in the ionic basis of lymphatic muscle contractile activity. We will then discuss lymphatic dysfunction observed with metabolic disruption and potential pathways to target with pharmacological approaches to improve lymphatic collecting vessel function.
Collapse
Affiliation(s)
- Yang Lee
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, TX, United States
| | - Scott D Zawieja
- Medical Pharmacology and Physiology, School of Medicine, University of Missouri, Columbia, MO, United States
| | - Mariappan Muthuchamy
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, TX, United States
| |
Collapse
|
6
|
Solari E, Marcozzi C, Ottaviani C, Negrini D, Moriondo A. Draining the Pleural Space: Lymphatic Vessels Facing the Most Challenging Task. BIOLOGY 2022; 11:biology11030419. [PMID: 35336793 PMCID: PMC8945018 DOI: 10.3390/biology11030419] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 02/25/2022] [Accepted: 03/08/2022] [Indexed: 01/06/2023]
Abstract
Simple Summary Fluid drainage operated by lymphatic vessels is crucial for a proper volume homeostasis of body compartments. This role is particularly relevant for the pleural cavity, where the hydraulic pressure of the pleural liquid is very subatmospheric and fluid filtering from the blood capillaries into the pleural space must be continuously removed to keep the pleural space volume low and to prevent accumulation of liquid causing impairments of the respiratory mechanics. In order to accomplish this task, lymphatic vessels of the pleural side of the diaphragm and those lying on the pleural surface of the chest wall must possess a negative intraluminal pressure which has to vary during the respiratory cycle to follow the similar variations occurring to the pressure of pleural liquid. This review focuses on the in vivo pressure measurements performed in sedated animal models to understand how these lymphatic networks can accomplish this complex but pivotal role. Abstract Lymphatic vessels exploit the mechanical stresses of their surroundings together with intrinsic rhythmic contractions to drain lymph from interstitial spaces and serosal cavities to eventually empty into the blood venous stream. This task is more difficult when the liquid to be drained has a very subatmospheric pressure, as it occurs in the pleural cavity. This peculiar space must maintain a very low fluid volume at negative hydraulic pressure in order to guarantee a proper mechanical coupling between the chest wall and lungs. To better understand the potential for liquid drainage, the key parameter to be considered is the difference in hydraulic pressure between the pleural space and the lymphatic lumen. In this review we collected old and new findings from in vivo direct measurements of hydraulic pressures in anaesthetized animals with the aim to better frame the complex physiology of diaphragmatic and intercostal lymphatics which drain liquid from the pleural cavity.
Collapse
|
7
|
Russell PS, Hong J, Trevaskis NL, Windsor JA, Martin ND, Phillips ARJ. Lymphatic Contractile Function: A Comprehensive Review of Drug Effects and Potential Clinical Application. Cardiovasc Res 2021; 118:2437-2457. [PMID: 34415332 DOI: 10.1093/cvr/cvab279] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Accepted: 08/18/2021] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND The lymphatic system and the cardiovascular system work together to maintain body fluid homeostasis. Despite that, the lymphatic system has been relatively neglected as a potential drug target and a source of adverse effects from cardiovascular drugs. Like the heart, the lymphatic vessels undergo phasic contractions to promote lymph flow against a pressure gradient. Dysfunction or failure of the lymphatic pump results in fluid imbalance and tissue oedema. While this can due to drug effects, it is also a feature of breast cancer-associated lymphoedema, chronic venous insufficiency, congestive heart failure and acute systemic inflammation. There are currently no specific drug treatments for lymphatic pump dysfunction in clinical use despite the wealth of data from pre-clinical studies. AIM To identify (1) drugs with direct effects on lymphatic tonic and phasic contractions with potential for clinical application, and (2) drugs in current clinical use that have a positive or negative side effect on lymphatic function. METHODS We comprehensively reviewed all studies that tested the direct effect of a drug on the contractile function of lymphatic vessels. RESULTS Of the 208 drugs identified from 193 studies, about a quarter had only stimulatory effects on lymphatic tone, contraction frequency and/or contraction amplitude. Of FDA-approved drugs, there were 14 that increased lymphatic phasic contractile function. The most frequently used class of drug with inhibitory effects on lymphatic pump function were the calcium channels blockers. CONCLUSION This review highlights the opportunity for specific drug treatments of lymphatic dysfunction in various disease states and for avoiding adverse drug effects on lymphatic contractile function.
Collapse
Affiliation(s)
- Peter S Russell
- Applied Surgery and Metabolism Laboratory, School of Biological Sciences, University of Auckland, Auckland, New Zealand.,Surgical and Translational Research Centre, Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Jiwon Hong
- Applied Surgery and Metabolism Laboratory, School of Biological Sciences, University of Auckland, Auckland, New Zealand.,Surgical and Translational Research Centre, Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Natalie L Trevaskis
- Monash Institute of Pharmaceutical Sciences, Faculty of Pharmacy and Pharmaceutical Sciences, Monash University, Melbourne, Australia
| | - John A Windsor
- Surgical and Translational Research Centre, Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Niels D Martin
- Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Anthony R J Phillips
- Applied Surgery and Metabolism Laboratory, School of Biological Sciences, University of Auckland, Auckland, New Zealand.,Surgical and Translational Research Centre, Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
8
|
Elich H, Barrett A, Shankar V, Fogelson AL. Pump efficacy in a two-dimensional, fluid-structure interaction model of a chain of contracting lymphangions. Biomech Model Mechanobiol 2021; 20:1941-1968. [PMID: 34275062 DOI: 10.1007/s10237-021-01486-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 06/26/2021] [Indexed: 11/25/2022]
Abstract
The transport of lymph through the lymphatic vasculature is the mechanism for returning excess interstitial fluid to the circulatory system, and it is essential for fluid homeostasis. Collecting lymphatic vessels comprise a significant portion of the lymphatic vasculature and are divided by valves into contractile segments known as lymphangions. Despite its importance, lymphatic transport in collecting vessels is not well understood. We present a computational model to study lymph flow through chains of valved, contracting lymphangions. We used the Navier-Stokes equations to model the fluid flow and the immersed boundary method to handle the two-way, fluid-structure interaction in 2D, non-axisymmetric simulations. We used our model to evaluate the effects of chain length, contraction style, and adverse axial pressure difference (AAPD) on cycle-mean flow rates (CMFRs). In the model, longer lymphangion chains generally yield larger CMFRs, and they fail to generate positive CMFRs at higher AAPDs than shorter chains. Simultaneously contracting pumps generate the largest CMFRs at nearly every AAPD and for every chain length. Due to the contraction timing and valve dynamics, non-simultaneous pumps generate lower CMFRs than the simultaneous pumps; the discrepancy diminishes as the AAPD increases. Valve dynamics vary with the contraction style and exhibit hysteretic opening and closing behaviors. Our model provides insight into how contraction propagation affects flow rates and transport through a lymphangion chain.
Collapse
Affiliation(s)
- Hallie Elich
- Department of Mathematics, University of Utah, Salt Lake City, UT, USA.
| | - Aaron Barrett
- Department of Mathematics, University of Utah, Salt Lake City, UT, USA
| | - Varun Shankar
- School of Computing, University of Utah, Salt Lake City, UT, USA
| | - Aaron L Fogelson
- Department of Mathematics, University of Utah, Salt Lake City, UT, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
9
|
Zhang X, Chakraborty S, Muthuchamy M, Zawieja DC. Isolation of Lymphatic Muscle Cells (LMCs ) from Rat Mesentery. Methods Mol Biol 2021; 2319:137-141. [PMID: 34331251 DOI: 10.1007/978-1-0716-1480-8_15] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Lymphatic muscle cells (LMCs), with unique characteristics resembling a combination of both cardiac and smooth muscle cells, play an essential role in the spontaneous contraction of the lymphatic vessels to pump fluid forward. However, our understanding of the more detailed molecular phenotypes of LMCs is limited. Here, we described a method to isolate the LMCs from rat mesentery and then culture the cells in vitro, which will serve a lot more molecular biology study of LMCs and significantly improve our knowledge about the unique characteristics of LMCs.
Collapse
Affiliation(s)
- Xueyang Zhang
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, TX, USA
| | - Sanjukta Chakraborty
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, TX, USA
| | - Mariappan Muthuchamy
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, TX, USA
| | - David C Zawieja
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, TX, USA.
| |
Collapse
|
10
|
Castorena-Gonzalez JA, Li M, Davis MJ. Effects of Elevated Downstream Pressure and the Role of Smooth Muscle Cell Coupling through Connexin45 on Lymphatic Pacemaking. Biomolecules 2020; 10:biom10101424. [PMID: 33050046 PMCID: PMC7600536 DOI: 10.3390/biom10101424] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 10/03/2020] [Accepted: 10/06/2020] [Indexed: 12/27/2022] Open
Abstract
Lymphatic vessels rely on spontaneous lymphatic muscle cell (LMC) contractions and one-way intraluminal valves to efficiently pump lymph and return it into the bloodstream. Intraluminal pressure is known to regulate the contractile function of lymphatics, with pressure elevation leading to increased contraction frequency and decreased amplitude. Contractions are normally initiated by a dominant pacemaker and are highly entrained among strongly coupled LMCs. Previously, we found that connexin45 is the major connexin isoform mediating LMC-LMC electrical coupling. Lymphatics from mice lacking smooth muscle connexin45 display uncoordinated, impaired contractions. Here, we utilized this connexin45-deficient model, pressure myography, and recently developed, novel analytical tools to assess the effects of elevated downstream pressure on the number, location, and frequency of lymphatic pacemakers. Our results show that, in vessels from healthy controls, an increase in downstream pressure resulted in the recruitment/development of new pacemakers and increased contractile frequency while a dominant pacemaker continued to be observed. In contrast, vessels from connexin45-deficient mice displayed significantly more pacemakers, but none were dominant; this worsened with elevated downstream pressure. These results suggest a potential protective mechanism through which the lymphatic vasculature adapts to transient increases in downstream pressure, but which may not be sustained in scenarios with chronic elevated downstream pressure.
Collapse
Affiliation(s)
- Jorge A. Castorena-Gonzalez
- Department of Medical Pharmacology and Physiology, School of Medicine, University of Missouri, Columbia, MO 65212, USA; (J.A.C.-G.); (M.L.)
- Department of Pharmacology, School of Medicine, Tulane University, New Orleans, LA 70112, USA
| | - Min Li
- Department of Medical Pharmacology and Physiology, School of Medicine, University of Missouri, Columbia, MO 65212, USA; (J.A.C.-G.); (M.L.)
| | - Michael J. Davis
- Department of Medical Pharmacology and Physiology, School of Medicine, University of Missouri, Columbia, MO 65212, USA; (J.A.C.-G.); (M.L.)
- Correspondence: ; Tel.: +1-(573)-884-5181
| |
Collapse
|
11
|
Zhu Q, Carlsson O, Rippe B. Clearance of Tracer Albumin from Peritoneal Cavity to Plasma at Low Intraperitoneal Volumes and Hydrostatic Pressures. Perit Dial Int 2020. [DOI: 10.1177/089686089801800507] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Objective To assess the clearance of radiolabeled tracer albumin (RISA) from peritoneal cavity to plasma (CI → P) in rats under essentially “normal” conditions, that is, when intraperitoneal hydrostatic pressure (IPP) is subatmospheric and the intraperitoneal (IP) “free” fluid volume (IPV) is low. Methods A volume of 0.3 mL of RISA was injected IP into anesthetized Wistar rats (wt = 300 g) when the IPV was approximately 2 mL (normal) or the IPV was approximately 10 mL, and IPP was either -1.8 mmHg (normal) or +1.5 mmHg (produced by an external cuff). Plasma samples (25 μL) were obtained repeatedly during the dwell, which lasted 30 300 min, after which the peritoneal cavity was opened to recover the IPV and residuallP RISA activity. The CI → P was assessed as the mass transfer of RISA into plasma, occurring per unit time,-divided by the calculated mean IP RISA concentration (CD). The interstitial RISA space was measured as the mass of RISA accumulated, per unit tissue weight, in peritoneal tissue samples divided by the CD. Results A markedly lower CI → P (2.47 ± 0.67 μL/min), as well as total RISA clearance out of the peritoneal cavity (CI), was found under “normal” conditions (an IPV of approximately 2 mL and an IPP of approximately -1.8 mmHg) compared to the situation during peritoneal dialysis (an IPV of approximately 20 mL and an IPP of +1 mmHg). Furthermore, the interstitial RISA space increased linearly over time even at negative IPPs and at an unchanging peritoneal interstitial fluid volume. At a low (normal) IPV the CI → P did not increase significantly with elevating IPP, and increased only marginally when tracer distribution was improved by artificial vibration of the rats. However the CI → P increased when larger volumes were infused to increase the totallPV. Conclusions It is concluded that the CI → P and CI at low IPPs and IPVs are not as high as during peritoneal dialysis. Increases in CI → P were, however, coupled to increases in IPV. This highlights the importance of the IPV per se and of a sufficient IP tracer distribution for direct lymphatic absorption to be efficient. This study was presented in part at the XVIth Annual Conference on Peritoneal Dialysis, Denver, Colorado, U.S.A., 1997 (33).
Collapse
Affiliation(s)
- Qing Zhu
- Departments of Nephrology and Physiology, University Hospital of Lund, Lund, Sweden
| | - Ola Carlsson
- Departments of Nephrology and Physiology, University Hospital of Lund, Lund, Sweden
| | - Bengt Rippe
- Departments of Nephrology and Physiology, University Hospital of Lund, Lund, Sweden
| |
Collapse
|
12
|
The effects of valve leaflet mechanics on lymphatic pumping assessed using numerical simulations. Sci Rep 2019; 9:10649. [PMID: 31337769 PMCID: PMC6650476 DOI: 10.1038/s41598-019-46669-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 06/20/2019] [Indexed: 01/04/2023] Open
Abstract
The lymphatic system contains intraluminal leaflet valves that function to bias lymph flow back towards the heart. These valves are present in the collecting lymphatic vessels, which generally have lymphatic muscle cells and can spontaneously pump fluid. Recent studies have shown that the valves are open at rest, can allow some backflow, and are a source of nitric oxide (NO). To investigate how these valves function as a mechanical valve and source of vasoactive species to optimize throughput, we developed a mathematical model that explicitly includes Ca2+ -modulated contractions, NO production and valve structures. The 2D lattice Boltzmann model includes an initial lymphatic vessel and a collecting lymphangion embedded in a porous tissue. The lymphangion segment has mechanically-active vessel walls and is flanked by deformable valves. Vessel wall motion is passively affected by fluid pressure, while active contractions are driven by intracellular Ca2+ fluxes. The model reproduces NO and Ca2+ dynamics, valve motion and fluid drainage from tissue. We find that valve structural properties have dramatic effects on performance, and that valves with a stiffer base and flexible tips produce more stable cycling. In agreement with experimental observations, the valves are a major source of NO. Once initiated, the contractions are spontaneous and self-sustained, and the system exhibits interesting non-linear dynamics. For example, increased fluid pressure in the tissue or decreased lymph pressure at the outlet of the system produces high shear stress and high levels of NO, which inhibits contractions. On the other hand, a high outlet pressure opposes the flow, increasing the luminal pressure and the radius of the vessel, which results in strong contractions in response to mechanical stretch of the wall. We also find that the location of contraction initiation is affected by the extent of backflow through the valves.
Collapse
|
13
|
Mukherjee A, Hooks J, Nepiyushchikh Z, Dixon JB. Entrainment of Lymphatic Contraction to Oscillatory Flow. Sci Rep 2019; 9:5840. [PMID: 30967585 PMCID: PMC6456495 DOI: 10.1038/s41598-019-42142-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Accepted: 03/26/2019] [Indexed: 12/28/2022] Open
Abstract
Lymphedema, a disfiguring condition characterized by an asymmetrical swelling of the limbs, is suspected to be caused by dysfunctions in the lymphatic system. A possible source of lymphatic dysfunction is the reduced mechanosensitivity of lymphangions, the spontaneously contracting units of the lymphatic system. In this study, the entrainment of lymphangions to an oscillatory wall shear stress (OWSS) is characterized in rat thoracic ducts in relation to their shear sensitivity. The critical shear stress above which the thoracic ducts show a substantial inhibition of contraction was found to be significantly negatively correlated to the diameter of the lymphangion. The entrainment of the lymphangion to an applied OWSS was found to be significantly dependent on the difference between the applied frequency and the intrinsic frequency of contraction of the lymphangion. The strength of the entrainment was also positively correlated to the applied shear stress when the applied shear was less than the critical shear stress of the vessel. The ejection fraction and fractional pump flow were also affected by the difference between the frequency of the applied OWSS and the vessel's intrinsic contraction frequency. The results suggest an adaptation of the lymphangion contractility to the existing oscillatory shear stress as a function of its intrinsic contractility and shear sensitivity. These adaptations might be crucial to ensure synchronized contraction of lymphangions through mechanosensitive means and might help explain the lymphatic dysfunctions that result from impaired mechanosensitivity.
Collapse
Affiliation(s)
- Anish Mukherjee
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, Georgia
| | - Joshua Hooks
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, Georgia
| | - Zhanna Nepiyushchikh
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, Georgia
| | - J Brandon Dixon
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, Georgia. .,Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, Georgia.
| |
Collapse
|
14
|
Moeller AL, Hjortdal VE, Boedtkjer DMB, Boedtkjer E. Acidosis inhibits rhythmic contractions of human thoracic ducts. Physiol Rep 2019; 7:e14074. [PMID: 31025551 PMCID: PMC6483936 DOI: 10.14814/phy2.14074] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 04/04/2019] [Accepted: 04/05/2019] [Indexed: 11/24/2022] Open
Abstract
Lymph vessels counteract edema by transporting interstitial fluid from peripheral tissues to the large veins and serve as conduits for immune cells, cancer cells, and pathogens. Because edema during inflammation and malignancies is frequently associated with acidosis, we tested the hypothesis that acid-base disturbances affect human thoracic duct contractions. We studied, by isometric and isobaric myography, the contractile function of human thoracic duct segments harvested with written informed consent from patients undergoing esophageal cancer surgery. Human thoracic ducts produce complex contractile patterns consisting of tonic rises in tension (isometric myography) or decreases in diameter (isobaric myography) with superimposed phasic contractions. Active tone development decreases substantially (~90% at 30 vs. 7 mmHg) at elevated transmural pressure. Acidosis inhibits spontaneous as well as noradrenaline- and serotonin-induced phasic contractions of human thoracic ducts by 70-90% at extracellular pH 6.8 compared to 7.4 with less pronounced effects observed at pH 7.1. Mean tension responses to noradrenaline and serotonin - averaged over the entire period of agonist exposure - decrease by ~50% at extracellular pH 6.8. Elevating extracellular [K+ ] from the normal resting level around 4 mmol/L increases overall tension development but reduces phasic activity to a level that is no different between human thoracic duct segments investigated at normal and low extracellular pH. In conclusion, we show that extracellular acidosis inhibits human thoracic duct contractions with more pronounced effects on phasic than tonic contractions. We propose that reduced phasic activity of lymph vessels at low pH attenuates lymph propulsion and increases the risk of edema formation.
Collapse
Affiliation(s)
| | | | - Donna M. B. Boedtkjer
- Department of BiomedicineAarhus UniversityAarhusDenmark
- Department of Clinical MedicineAarhus UniversityAarhusDenmark
| | | |
Collapse
|
15
|
|
16
|
Alderfer L, Wei A, Hanjaya-Putra D. Lymphatic Tissue Engineering and Regeneration. J Biol Eng 2018; 12:32. [PMID: 30564284 PMCID: PMC6296077 DOI: 10.1186/s13036-018-0122-7] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 11/19/2018] [Indexed: 12/22/2022] Open
Abstract
The lymphatic system is a major circulatory system within the body, responsible for the transport of interstitial fluid, waste products, immune cells, and proteins. Compared to other physiological systems, the molecular mechanisms and underlying disease pathology largely remain to be understood which has hindered advancements in therapeutic options for lymphatic disorders. Dysfunction of the lymphatic system is associated with a wide range of disease phenotypes and has also been speculated as a route to rescue healthy phenotypes in areas including cardiovascular disease, metabolic syndrome, and neurological conditions. This review will discuss lymphatic system functions and structure, cell sources for regenerating lymphatic vessels, current approaches for engineering lymphatic vessels, and specific therapeutic areas that would benefit from advances in lymphatic tissue engineering and regeneration.
Collapse
Affiliation(s)
- Laura Alderfer
- Department of Aerospace and Mechanical Engineering, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, IN 46556 USA
| | - Alicia Wei
- Department of Aerospace and Mechanical Engineering, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, IN 46556 USA
| | - Donny Hanjaya-Putra
- Department of Aerospace and Mechanical Engineering, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, IN 46556 USA
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN 46656 USA
- Harper Cancer Research Institute, University of Notre Dame, Notre Dame, IN 46556 USA
- Center for Stem Cells and Regenerative Medicine, University of Notre Dame, Notre Dame, IN 46556 USA
- Advanced Diagnostics and Therapeutics, University of Notre Dame, Notre Dame, IN 46556 USA
- Center for Nanoscience and Technology (NDnano), University of Notre Dame, Notre Dame, IN 46556 USA
| |
Collapse
|
17
|
Castorena-Gonzalez JA, Zawieja SD, Li M, Srinivasan RS, Simon AM, de Wit C, de la Torre R, Martinez-Lemus LA, Hennig GW, Davis MJ. Mechanisms of Connexin-Related Lymphedema. Circ Res 2018; 123:964-985. [PMID: 30355030 PMCID: PMC6771293 DOI: 10.1161/circresaha.117.312576] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
RATIONALE Mutations in GJC2 and GJA1, encoding Cxs (connexins) 47 and 43, respectively, are linked to lymphedema, but the underlying mechanisms are unknown. Because efficient lymph transport relies on the coordinated contractions of lymphatic muscle cells (LMCs) and their electrical coupling through Cxs, Cx-related lymphedema is proposed to result from dyssynchronous contractions of lymphatic vessels. OBJECTIVE To determine which Cx isoforms in LMCs and lymphatic endothelial cells are required for the entrainment of lymphatic contraction waves and efficient lymph transport. METHODS AND RESULTS We developed novel methods to quantify the spatiotemporal entrainment of lymphatic contraction waves and used optogenetic techniques to analyze calcium signaling within and between the LMC and the lymphatic endothelial cell layers. Genetic deletion of the major lymphatic endothelial cell Cxs (Cx43, Cx47, or Cx37) revealed that none were necessary for the synchronization of the global calcium events that triggered propagating contraction waves. We identified Cx45 in human and mouse LMCs as the critical Cx mediating the conduction of pacemaking signals and entrained contractions. Smooth muscle-specific Cx45 deficiency resulted in 10- to 18-fold reduction in conduction speed, partial-to-severe loss of contractile coordination, and impaired lymph pump function ex vivo and in vivo. Cx45 deficiency resulted in profound inhibition of lymph transport in vivo, but only under an imposed gravitational load. CONCLUSIONS Our results (1) identify Cx45 as the Cx isoform mediating the entrainment of the contraction waves in LMCs; (2) show that major endothelial Cxs are dispensable for the entrainment of contractions; (3) reveal a lack of coupling between lymphatic endothelial cells and LMCs, in contrast to arterioles; (4) point to lymphatic valve defects, rather than contraction dyssynchrony, as the mechanism underlying GJC2- or GJA1-related lymphedema; and (5) show that a gravitational load exacerbates lymphatic contractile defects in the intact mouse hindlimb, which is likely critical for the development of lymphedema in the adult mouse.
Collapse
Affiliation(s)
| | - Scott D. Zawieja
- Dept. of Medical Pharmacology and Physiology and University of Missouri School of Medicine
| | - Min Li
- Dept. of Medical Pharmacology and Physiology and University of Missouri School of Medicine
| | - R. Sathish Srinivasan
- Cardiovascular Biology Research Program, Oklahoma Medical Research Foundation, Oklahoma City OK
| | | | - Cor de Wit
- Institute of Physiology, University of Luebeck, Luebeck Germany
| | | | - Luis A. Martinez-Lemus
- Dept. of Medical Pharmacology and Physiology and University of Missouri School of Medicine
| | | | - Michael J. Davis
- Dept. of Medical Pharmacology and Physiology and University of Missouri School of Medicine
| |
Collapse
|
18
|
Hald BO, Castorena-Gonzalez JA, Zawieja SD, Gui P, Davis MJ. Electrical Communication in Lymphangions. Biophys J 2018; 115:936-949. [PMID: 30143234 DOI: 10.1016/j.bpj.2018.07.033] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Revised: 07/02/2018] [Accepted: 07/19/2018] [Indexed: 11/30/2022] Open
Abstract
Contractions of lymphangions, i.e., the segment between two one-way lymphatic valves, generate the pressure gradients that propel lymph back to the circulation. Each lymphangion is comprised of an inner sheet of lymphatic endothelial cells circumscribed by one or more layers of lymphatic muscle cells (LMCs). Each contraction is produced by an LMC action potential (AP) that propagates via gap junctions along the lymphangion. Yet, electrical coupling within and between cell layers and the impact on AP waves is poorly understood. Here, we combine studies in rat and mouse lymphatic vessels with mathematical modeling to show that initiation of AP waves depends on high input resistance (low current drain), whereas propagation depends on morphology and sufficient LMC:LMC coupling. Simulations show that 1) myoendothelial coupling is insignificant to facilitate AP generation and sustain an experimentally measured cross-junctional potential difference of 25 mV, i.e., AP waves propagate along the LMC layer only; 2) LMC:LMC resistance is estimated around 2-10 MΩ but depends on vessel structure and cell-cell coupling, e.g., some degree of LMC overlap protects AP waves against LMC decoupling; 3) the propensity of AP wave initiation is highest around the valves, where the density of LMCs is low; and 4) a single pacemaker cell embedded in the LMC layer must be able to generate very large currents to overcome the current drain from the layer. However, the required current generation to initiate an AP wave is reduced upon stimulation of multiple adjacent LMCs. With stimulation of all LMCs, AP waves can also arise from heterogeneity in the electrical activity of LMCs. The findings advance our understanding of the electrical constraints that underlie initiation of APs in the LMC layer and make testable predictions about how morphology, LMC excitability, and LMC:LMC electrical coupling interact to determine the ability to initiate and propagate AP waves in small lymphatic vessels.
Collapse
Affiliation(s)
- Bjørn Olav Hald
- Department of Neuroscience, University of Copenhagen, Copenhagen, Denmark
| | - Jorge Augusto Castorena-Gonzalez
- Department of Medical Pharmacology and Physiology, Dalton Cardiovascular Research Center, University of Missouri, Columbia, Missouri
| | - Scott David Zawieja
- Department of Medical Pharmacology and Physiology, Dalton Cardiovascular Research Center, University of Missouri, Columbia, Missouri
| | - Peichun Gui
- Department of Medical Pharmacology and Physiology, Dalton Cardiovascular Research Center, University of Missouri, Columbia, Missouri
| | - Michael John Davis
- Department of Medical Pharmacology and Physiology, Dalton Cardiovascular Research Center, University of Missouri, Columbia, Missouri.
| |
Collapse
|
19
|
Contraction of collecting lymphatics: organization of pressure-dependent rate for multiple lymphangions. Biomech Model Mechanobiol 2018; 17:1513-1532. [PMID: 29948540 DOI: 10.1007/s10237-018-1042-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 05/28/2018] [Indexed: 02/07/2023]
Abstract
The paper describes the extension of a previously developed model of pressure-dependent contraction rate to the case of multiple lymphangions. Mechanical factors are key modulators of active lymphatic pumping. As part of the evolution of our lumped-parameter model to match experimental findings, we have designed an algorithm whereby the time until the next contraction depends on lymphangion transmural pressure in the contraction just completed. The functional dependence of frequency on pressure is quantitatively matched to isobaric contraction experiments on isolated lymphatic segments. When each of several lymphangions is given this ability, a scheme for their coordination must be instituted to match the observed synchronization. Accordingly, and in line with an experiment on an isolated lymphatic vessel segment in which we measured contraction sequence and conduction delay, we took the fundamental principle to be that local timing can be overridden by signals to initiate contraction that start in adjacent lymphangions, conducted with a short delay. The scheme leads to retrograde conduction when the lymphangion chain is pumping against an adverse pressure difference, but antegrade conduction when contractions occur with no or a favourable pressure difference. Abolition of these conducted signals leads to chaotic variation of cycle-mean flow-rate from the chain, diastolic duration in each lymphangion, and inter-lymphangion delays. Chaotic rhythm is also seen under other circumstances. Because the model responds to increasing adverse pressure difference by increasing the repetition rate of contractions, it maintains time-average output flow-rate better than one with fixed repetition rate.
Collapse
|
20
|
Meens MJ, Kutkut I, Rochemont V, Dubrot J, Kaladji FR, Sabine A, Lyons O, Hendrikx S, Bernier-Latmani J, Kiefer F, Smith A, Hugues S, Petrova TV, Kwak BR. Cx47 fine-tunes the handling of serum lipids but is dispensable for lymphatic vascular function. PLoS One 2017; 12:e0181476. [PMID: 28732089 PMCID: PMC5521787 DOI: 10.1371/journal.pone.0181476] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2017] [Accepted: 06/30/2017] [Indexed: 12/04/2022] Open
Abstract
Mutations in the gap junction protein connexin47 (Cx47) are associated with lymphedema. However, the role of Cx47 in lymphatic pathophysiology is unknown. We demonstrate that Cx47 is expressed in lymphatic endothelial cells by whole-mount immunostaining and qPCR. To determine if Cx47 plays a role in lymphatic vessel function we analysed Cx47-/- mice. Cx47-deficiency did not affect lymphatic contractility (contractile amplitude or frequency) or lymphatic morphology (vessel diameter or number of valves). Interstitial fluid drainage or dendritic cell migration through lymphatic vessels was also not affected by Cx47-deficiency. Cx47 is dispensable for long-chain fatty acid absorption from the gut but rather promotes serum lipid handling as prolonged elevated triglyceride levels were observed in Cx47-deficient mice after oral lipid tolerance tests. When crossed with Apolipoprotein E-deficient (Apoe-/-) mice, LDL-cholesterol was decreased in young Cx47-/-Apoe-/- adults as compared to Apoe-/- mice, which was inverted later in life. Finally, advanced atherosclerotic plaques in thoracic-abdominal aortas of 15 months-old mice tended to be larger in Cx47-/-Apoe-/- mice. These plaques contained fewer macrophages but similar amounts of T lymphocytes, collagen and lipids than plaques of Apoe-/- mice. In conclusion, Cx47 is expressed in lymphatic endothelium and seems modestly implicated in multiple aspects of lymphatic pathophysiology.
Collapse
Affiliation(s)
- Merlijn J. Meens
- Department of Pathology and Immunology, University of Geneva, Geneva, Switzerland
- * E-mail:
| | - Issa Kutkut
- Department of Pathology and Immunology, University of Geneva, Geneva, Switzerland
| | - Viviane Rochemont
- Department of Pathology and Immunology, University of Geneva, Geneva, Switzerland
| | - Juan Dubrot
- Department of Pathology and Immunology, University of Geneva, Geneva, Switzerland
| | - Fouad R. Kaladji
- Department of Pathology and Immunology, University of Geneva, Geneva, Switzerland
| | - Amélie Sabine
- Department of Fundamental Oncology, Centre Hospitalier Universitaire Vaudois (CHUV), University of Lausanne, Lausanne, Switzerland
- Division of Experimental Pathology, Institute of Pathology, CHUV, Lausanne, Switzerland
| | - Oliver Lyons
- Academic Department of Vascular Surgery, Cardiovascular Division, King's College London, BHF Centre of Research Excellence & NIHR Biomedical Research Centre at King's Health Partners, St Thomas' Hospital, London, United Kingdom
| | - Stefanie Hendrikx
- Department of Fundamental Oncology, Centre Hospitalier Universitaire Vaudois (CHUV), University of Lausanne, Lausanne, Switzerland
- Division of Experimental Pathology, Institute of Pathology, CHUV, Lausanne, Switzerland
| | - Jeremiah Bernier-Latmani
- Department of Fundamental Oncology, Centre Hospitalier Universitaire Vaudois (CHUV), University of Lausanne, Lausanne, Switzerland
- Division of Experimental Pathology, Institute of Pathology, CHUV, Lausanne, Switzerland
| | - Friedemann Kiefer
- Mammalian Cell Signalling Laboratory, Department of Vascular Cell Biology, Max Planck Institute for Molecular Biomedicine, Münster, Germany
| | - Alberto Smith
- Academic Department of Vascular Surgery, Cardiovascular Division, King's College London, BHF Centre of Research Excellence & NIHR Biomedical Research Centre at King's Health Partners, St Thomas' Hospital, London, United Kingdom
| | - Stéphanie Hugues
- Department of Pathology and Immunology, University of Geneva, Geneva, Switzerland
| | - Tatiana V. Petrova
- Department of Fundamental Oncology, Centre Hospitalier Universitaire Vaudois (CHUV), University of Lausanne, Lausanne, Switzerland
- Division of Experimental Pathology, Institute of Pathology, CHUV, Lausanne, Switzerland
- Swiss Institute for Experimental Cancer Research, School of Life Sciences, Swiss Federal Institute of Technology Lausanne, Lausanne, Switzerland
| | - Brenda R. Kwak
- Department of Pathology and Immunology, University of Geneva, Geneva, Switzerland
- Department of Medical Specialties – Cardiology, University of Geneva, Geneva, Switzerland
| |
Collapse
|
21
|
Telinius N, Majgaard J, Mohanakumar S, Pahle E, Nielsen J, Hjortdal V, Aalkjær C, Boedtkjer DB. Spontaneous and Evoked Contractility of Human Intestinal Lymphatic Vessels. Lymphat Res Biol 2017; 15:17-22. [DOI: 10.1089/lrb.2016.0039] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Niklas Telinius
- Department of Biomedicine, Aarhus University, Aarhus, Denmark
- Department of Cardiothoracic Surgery, Aarhus University Hospital, Aarhus, Denmark
| | - Jens Majgaard
- Department of Biomedicine, Aarhus University, Aarhus, Denmark
| | - Sheyanth Mohanakumar
- Department of Biomedicine, Aarhus University, Aarhus, Denmark
- Department of Cardiothoracic Surgery, Aarhus University Hospital, Aarhus, Denmark
| | - Einar Pahle
- Department of Surgery, Viborg Hospital, Viborg, Denmark
| | - Jørn Nielsen
- Department of Surgery, Viborg Hospital, Viborg, Denmark
| | - Vibeke Hjortdal
- Department of Cardiothoracic Surgery, Aarhus University Hospital, Aarhus, Denmark
| | | | - Donna Briggs Boedtkjer
- Department of Biomedicine, Aarhus University, Aarhus, Denmark
- Department of Cardiothoracic Surgery, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
22
|
Scallan JP, Zawieja SD, Castorena-Gonzalez JA, Davis MJ. Lymphatic pumping: mechanics, mechanisms and malfunction. J Physiol 2016; 594:5749-5768. [PMID: 27219461 PMCID: PMC5063934 DOI: 10.1113/jp272088] [Citation(s) in RCA: 229] [Impact Index Per Article: 28.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2015] [Accepted: 05/17/2016] [Indexed: 12/19/2022] Open
Abstract
A combination of extrinsic (passive) and intrinsic (active) forces move lymph against a hydrostatic pressure gradient in most regions of the body. The effectiveness of the lymph pump system impacts not only interstitial fluid balance but other aspects of overall homeostasis. This review focuses on the mechanisms that regulate the intrinsic, active contractions of collecting lymphatic vessels in relation to their ability to actively transport lymph. Lymph propulsion requires not only robust contractions of lymphatic muscle cells, but contraction waves that are synchronized over the length of a lymphangion as well as properly functioning intraluminal valves. Normal lymphatic pump function is determined by the intrinsic properties of lymphatic muscle and the regulation of pumping by lymphatic preload, afterload, spontaneous contraction rate, contractility and neural influences. Lymphatic contractile dysfunction, barrier dysfunction and valve defects are common themes among pathologies that directly involve the lymphatic system, such as inherited and acquired forms of lymphoedema, and pathologies that indirectly involve the lymphatic system, such as inflammation, obesity and metabolic syndrome, and inflammatory bowel disease.
Collapse
Affiliation(s)
- Joshua P Scallan
- Department of Medical Pharmacology and Physiology, University of Missouri, Columbia, MO, USA
| | - Scott D Zawieja
- Department of Medical Pharmacology and Physiology, University of Missouri, Columbia, MO, USA
| | | | - Michael J Davis
- Department of Medical Pharmacology and Physiology, University of Missouri, Columbia, MO, USA.
| |
Collapse
|
23
|
Cintolesi V, Stanton AW, Bains SK, Cousins E, Peters AM, Purushotham AD, Levick JR, Mortimer PS. Constitutively Enhanced Lymphatic Pumping in the Upper Limbs of Women Who Later Develop Breast Cancer-Related Lymphedema. Lymphat Res Biol 2016; 14:50-61. [DOI: 10.1089/lrb.2016.0005] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Affiliation(s)
- Viviana Cintolesi
- Cardiovascular and Cell Sciences Research Institute, St George's, University of London, London, United Kingdom
| | - Anthony W.B. Stanton
- Cardiovascular and Cell Sciences Research Institute, St George's, University of London, London, United Kingdom
| | - Salena K. Bains
- Department of Research Oncology, King's College London, Guy's Hospital, London, United Kingdom
| | - Emma Cousins
- Cardiovascular and Cell Sciences Research Institute, St George's, University of London, London, United Kingdom
| | - A. Michael Peters
- Department of Nuclear Medicine, Brighton and Sussex University Hospitals NHS Trust, Brighton, United Kingdom
| | - Arnie D. Purushotham
- Department of Research Oncology, King's College London, Guy's Hospital, London, United Kingdom
| | - J. Rodney Levick
- Cardiovascular and Cell Sciences Research Institute, St George's, University of London, London, United Kingdom
| | - Peter S. Mortimer
- Cardiovascular and Cell Sciences Research Institute, St George's, University of London, London, United Kingdom
- Department of Dermatology, St George's University Hospitals NHS Foundation Trust, London, United Kindom
- Skin Unit, The Royal Marsden NHS Foundation Trust, Sutton, Surrey, United Kingdom
| |
Collapse
|
24
|
Jamalian S, Davis MJ, Zawieja DC, Moore JE. Network Scale Modeling of Lymph Transport and Its Effective Pumping Parameters. PLoS One 2016; 11:e0148384. [PMID: 26845031 PMCID: PMC4742072 DOI: 10.1371/journal.pone.0148384] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2015] [Accepted: 01/18/2016] [Indexed: 11/18/2022] Open
Abstract
The lymphatic system is an open-ended network of vessels that run in parallel to the blood circulation system. These vessels are present in almost all of the tissues of the body to remove excess fluid. Similar to blood vessels, lymphatic vessels are found in branched arrangements. Due to the complexity of experiments on lymphatic networks and the difficulty to control the important functional parameters in these setups, computational modeling becomes an effective and essential means of understanding lymphatic network pumping dynamics. Here we aimed to determine the effect of pumping coordination in branched network structures on the regulation of lymph flow. Lymphatic vessel networks were created by building upon our previous lumped-parameter model of lymphangions in series. In our network model, each vessel is itself divided into multiple lymphangions by lymphatic valves that help maintain forward flow. Vessel junctions are modeled by equating the pressures and balancing mass flows. Our results demonstrated that a 1.5 s rest-period between contractions optimizes the flow rate. A time delay between contractions of lymphangions at the junction of branches provided an advantage over synchronous pumping, but additional time delays within individual vessels only increased the flow rate for adverse pressure differences greater than 10.5 cmH2O. Additionally, we quantified the pumping capability of the system under increasing levels of steady transmural pressure and outflow pressure for different network sizes. We observed that peak flow rates normally occurred under transmural pressures between 2 to 4 cmH2O (for multiple pressure differences and network sizes). Networks with 10 lymphangions per vessel had the highest pumping capability under a wide range of adverse pressure differences. For favorable pressure differences, pumping was more efficient with fewer lymphangions. These findings are valuable for translating experimental measurements from the single lymphangion level to tissue and organ scales.
Collapse
Affiliation(s)
- Samira Jamalian
- Department of Bioengineering, Imperial College London, South Kensington Campus, London, United Kingdom
| | - Michael J. Davis
- Department of Pharmacology and Physiology, University of Missouri School of Medicine, Columbia, MO, United States of America
| | - David C. Zawieja
- Department of Systems Biology and Translational Medicine, Texas A&M Health Science Center, Temple, TX, United States of America
| | - James E. Moore
- Department of Bioengineering, Imperial College London, South Kensington Campus, London, United Kingdom
- * E-mail:
| |
Collapse
|
25
|
Bertram CD, Macaskill C, Davis MJ, Moore JE. Consequences of intravascular lymphatic valve properties: a study of contraction timing in a multi-lymphangion model. Am J Physiol Heart Circ Physiol 2016; 310:H847-60. [PMID: 26747501 DOI: 10.1152/ajpheart.00669.2015] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Accepted: 01/04/2016] [Indexed: 11/22/2022]
Abstract
The observed properties of valves in collecting lymphatic vessels include transmural pressure-dependent bias to the open state and hysteresis. The bias may reduce resistance to flow when the vessel is functioning as a conduit. However, lymphatic pumping implies a streamwise increase in mean pressure across each valve, suggesting that the bias is then potentially unhelpful. Lymph pumping by a model of several collecting lymphatic vessel segments (lymphangions) in series, which incorporated these properties, was investigated under conditions of adverse pressure difference while varying the refractory period between active muscular contractions and the inter-lymphangion contraction delay. It was found that many combinations of the timing parameters and the adverse pressure difference led to one or more intermediate valves remaining open instead of switching between open and closed states during repetitive contraction cycles. Cyclic valve switching was reliably indicated if the mean pressure in a lymphangion over a cycle was higher than that in the lymphangion upstream, but either lack of or very brief valve closure could cause mean pressure to be lower downstream. Widely separated combinations of refractory period and delay time were found to produce the greatest flow-rate for a given pressure difference. The efficiency of pumping was always maximized by a long refractory period and lymphangion contraction starting when the contraction of the lymphangion immediately upstream was peaking. By means of an ex vivo experiment, it was verified that intermediate valves in a chain of pumping lymphangions can remain open, while the lymphangions on either side of the open valve continue to execute contractions.
Collapse
Affiliation(s)
- Christopher D Bertram
- School of Mathematics and Statistics, University of Sydney, New South Wales, Australia;
| | - Charlie Macaskill
- School of Mathematics and Statistics, University of Sydney, New South Wales, Australia
| | - Michael J Davis
- Department of Medical Pharmacology and Physiology, University of Missouri School of Medicine, Columbia, Missouri; and
| | - James E Moore
- Department of Bioengineering, Imperial College, London, United Kingdom
| |
Collapse
|
26
|
Huethorst E, Krebber MM, Fledderus JO, Gremmels H, Xu YJ, Pei J, Verhaar MC, Cheng C. Lymphatic Vascular Regeneration: The Next Step in Tissue Engineering. TISSUE ENGINEERING PART B-REVIEWS 2015. [PMID: 26204330 DOI: 10.1089/ten.teb.2015.0231] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
The lymphatic system plays a crucial role in interstitial fluid drainage, lipid absorption, and immunological defense. Lymphatic dysfunction results in lymphedema, fluid accumulation, and swelling of soft tissues, as well as a potentially impaired immune response. Lymphedema significantly reduces quality of life of patients on a physical, mental, social, and economic basis. Current therapeutic approaches in treatment of lymphatic disease are limited. Over the last decades, great progress has been made in the development of therapeutic strategies to enhance vascular regeneration. These solutions to treat vascular disease may also be applicable in the treatment of lymphatic diseases. Comparison of the organogenic process and biological organization of the vascular and lymphatic systems and studies in the regulatory mechanisms involved in lymphangiogenesis and angiogenesis show many common features. In this study, we address the similarities between both transport systems, and focus in depth on the biology of lymphatic development. Based on the current advances in vascular regeneration, we propose different strategies for lymphatic tissue engineering that may be used for treatment of primary and secondary lymphedema.
Collapse
Affiliation(s)
- Eline Huethorst
- 1 Department of Nephrology and Hypertension, DIGD, University Medical Center Utrecht , Utrecht, The Netherlands
| | - Merle M Krebber
- 1 Department of Nephrology and Hypertension, DIGD, University Medical Center Utrecht , Utrecht, The Netherlands
| | - Joost O Fledderus
- 1 Department of Nephrology and Hypertension, DIGD, University Medical Center Utrecht , Utrecht, The Netherlands
| | - Hendrik Gremmels
- 1 Department of Nephrology and Hypertension, DIGD, University Medical Center Utrecht , Utrecht, The Netherlands
| | - Yan Juan Xu
- 1 Department of Nephrology and Hypertension, DIGD, University Medical Center Utrecht , Utrecht, The Netherlands
| | - Jiayi Pei
- 1 Department of Nephrology and Hypertension, DIGD, University Medical Center Utrecht , Utrecht, The Netherlands
| | - Marianne C Verhaar
- 1 Department of Nephrology and Hypertension, DIGD, University Medical Center Utrecht , Utrecht, The Netherlands
| | - Caroline Cheng
- 1 Department of Nephrology and Hypertension, DIGD, University Medical Center Utrecht , Utrecht, The Netherlands .,2 Division of Experimental Cardiology, Department of Cardiology, Thoraxcenter , Rotterdam, The Netherlands
| |
Collapse
|
27
|
Kornuta JA, Nepiyushchikh Z, Gasheva OY, Mukherjee A, Zawieja DC, Dixon JB. Effects of dynamic shear and transmural pressure on wall shear stress sensitivity in collecting lymphatic vessels. Am J Physiol Regul Integr Comp Physiol 2015; 309:R1122-34. [PMID: 26333787 DOI: 10.1152/ajpregu.00342.2014] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2014] [Accepted: 08/25/2015] [Indexed: 01/13/2023]
Abstract
Given the known mechanosensitivity of the lymphatic vasculature, we sought to investigate the effects of dynamic wall shear stress (WSS) on collecting lymphatic vessels while controlling for transmural pressure. Using a previously developed ex vivo lymphatic perfusion system (ELPS) capable of independently controlling both transaxial pressure gradient and average transmural pressure on an isolated lymphatic vessel, we imposed a multitude of flow conditions on rat thoracic ducts, while controlling for transmural pressure and measuring diameter changes. By gradually increasing the imposed flow through a vessel, we determined the WSS at which the vessel first shows sign of contraction inhibition, defining this point as the shear stress sensitivity of the vessel. The shear stress threshold that triggered a contractile response was significantly greater at a transmural pressure of 5 cmH2O (0.97 dyne/cm(2)) than at 3 cmH2O (0.64 dyne/cm(2)). While contraction frequency was reduced when a steady WSS was applied, this inhibition was reversed when the applied WSS oscillated, even though the mean wall shear stresses between the conditions were not significantly different. When the applied oscillatory WSS was large enough, flow itself synchronized the lymphatic contractions to the exact frequency of the applied waveform. Both transmural pressure and the rate of change of WSS have significant impacts on the contractile response of lymphatic vessels to flow. Specifically, time-varying shear stress can alter the inhibition of phasic contraction frequency and even coordinate contractions, providing evidence that dynamic shear could play an important role in the contractile function of collecting lymphatic vessels.
Collapse
Affiliation(s)
- Jeffrey A Kornuta
- Parker H. Petite Institute of Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Zhanna Nepiyushchikh
- Parker H. Petite Institute of Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Olga Y Gasheva
- Department of Medical Physiology, Texas A&M Health Science Center College of Medicine, Temple, Texas
| | - Anish Mukherjee
- Parker H. Petite Institute of Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia; School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia; and
| | - David C Zawieja
- Department of Medical Physiology, Texas A&M Health Science Center College of Medicine, Temple, Texas
| | - J Brandon Dixon
- Parker H. Petite Institute of Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia;
| |
Collapse
|
28
|
Abstract
The ability of cells to sense and respond to physical forces has been recognized for decades, but researchers are only beginning to appreciate the fundamental importance of mechanical signals in biology. At the larger scale, there has been increased interest in the collective organization of cells and their ability to produce complex, "emergent" behaviors. Often, these complex behaviors result in tissue-level control mechanisms that manifest as biological oscillators, such as observed in fireflies, heartbeats, and circadian rhythms. In many cases, these complex, collective behaviors are controlled--at least in part--by physical forces imposed on the tissue or created by the cells. Here, we use mathematical simulations to show that two complementary mechanobiological oscillators are sufficient to control fluid transport in the lymphatic system: Ca(2+)-mediated contractions can be triggered by vessel stretch, whereas nitric oxide produced in response to the resulting fluid shear stress causes the lymphatic vessel to relax locally. Our model predicts that the Ca(2+) and NO levels alternate spatiotemporally, establishing complementary feedback loops, and that the resulting phasic contractions drive lymph flow. We show that this mechanism is self-regulating and robust over a range of fluid pressure environments, allowing the lymphatic vessels to provide pumping when needed but remain open when flow can be driven by tissue pressure or gravity. Our simulations accurately reproduce the responses to pressure challenges and signaling pathway manipulations observed experimentally, providing an integrated conceptual framework for lymphatic function.
Collapse
|
29
|
Glass AM, Snyder EG, Taffet SM. Connexins and pannexins in the immune system and lymphatic organs. Cell Mol Life Sci 2015; 72:2899-910. [PMID: 26100515 PMCID: PMC11113820 DOI: 10.1007/s00018-015-1966-3] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2015] [Accepted: 06/11/2015] [Indexed: 12/11/2022]
Abstract
Connexin43 and pannexin1 are found in immune cells. While gap junctional communication has been demonstrated between immune cells, hemichannels have been implicated in many cellular functions. Among the functions involved as being connexin dependent and pannexin dependent are cell migration, phagocytosis, antigen presentation, T-cell reactivity and B-cell responses. Surprisingly, many of these connexin-related and pannexin-related functions are not recapitulated in in vivo models. This is leading to a reevaluation of the role of these proteins in immune function.
Collapse
Affiliation(s)
- Aaron M. Glass
- Department of Microbiology and Immunology, SUNY Upstate Medical University, 750 E Adams Street, Syracuse, NY 13210 USA
| | - Elizabeth G. Snyder
- Department of Microbiology and Immunology, SUNY Upstate Medical University, 750 E Adams Street, Syracuse, NY 13210 USA
| | - Steven M. Taffet
- Department of Microbiology and Immunology, SUNY Upstate Medical University, 750 E Adams Street, Syracuse, NY 13210 USA
| |
Collapse
|
30
|
Munn LL. Mechanobiology of lymphatic contractions. Semin Cell Dev Biol 2015; 38:67-74. [PMID: 25636584 DOI: 10.1016/j.semcdb.2015.01.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2014] [Revised: 01/20/2015] [Accepted: 01/21/2015] [Indexed: 01/30/2023]
Abstract
The lymphatic system is responsible for controlling tissue fluid pressure by facilitating flow of lymph (i.e. the plasma and cells that enter the lymphatic system). Because lymph contains cells of the immune system, its transport is not only important for fluid homeostasis, but also immune function. Lymph drainage can occur via passive flow or active pumping, and much research has identified the key biochemical and mechanical factors that affect output. Although many studies and reviews have addressed how tissue properties and fluid mechanics (i.e. pressure gradients) affect lymph transport [1-3] there is less known about lymphatic mechanobiology. As opposed to passive mechanical properties, mechanobiology describes the active coupling of mechanical signals and biochemical pathways. Lymphatic vasomotion is the result of a fascinating system affected by mechanical forces exerted by the flowing lymph, including pressure-induced vessel stretch and flow-induced shear stresses. These forces can trigger or modulate biochemical pathways important for controlling the lymphatic contractions. Here, I review the current understanding of lymphatic vessel function, focusing on vessel mechanobiology, and summarize the prospects for a comprehensive understanding that integrates the mechanical and biomechanical control mechanisms in the lymphatic system.
Collapse
Affiliation(s)
- Lance L Munn
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, United States.
| |
Collapse
|
31
|
Dongaonkar RM, Nguyen TL, Quick CM, Heaps CL, Hardy J, Laine GA, Wilson E, Stewart RH. Mesenteric lymphatic vessels adapt to mesenteric venous hypertension by becoming weaker pumps. Am J Physiol Regul Integr Comp Physiol 2014; 308:R391-9. [PMID: 25519727 DOI: 10.1152/ajpregu.00196.2014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Lymphangions, the segments of lymphatic vessels between two adjacent lymphatic valves, actively pump lymph. Acute changes in transmural pressure and lymph flow have profound effects on lymphatic pump function in vitro. Chronic changes in pressure and flow in vivo have also been reported to lead to significant changes in lymphangion function. Because changes in pressure and flow are both cause and effect of adaptive processes, characterizing adaptation requires a more fundamental analysis of lymphatic muscle properties. Therefore, the purpose of the present work was to use an intact lymphangion isovolumetric preparation to evaluate changes in mesenteric lymphatic muscle mechanical properties and the intracellular Ca(2+) in response to sustained mesenteric venous hypertension. Bovine mesenteric veins were surgically occluded to create mesenteric venous hypertension. Postnodal mesenteric lymphatic vessels from mesenteric venous hypertension (MVH; n = 6) and sham surgery (Sham; n = 6) animals were isolated and evaluated 3 days after the surgery. Spontaneously contracting MVH vessels generated end-systolic active tension and end-diastolic active tension lower than the Sham vessels. Furthermore, steady-state active tension and intracellular Ca(2+) concentration levels in response to KCl stimulation were also significantly lower in MVH vessels compared with those of the Sham vessels. There was no significant difference in passive tension in lymphatic vessels from the two groups. Taken together, these results suggest that following 3 days of mesenteric venous hypertension, postnodal mesenteric lymphatic vessels adapt to become weaker pumps with decreased cytosolic Ca(2+) concentration.
Collapse
Affiliation(s)
- R M Dongaonkar
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| | - T L Nguyen
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| | - C M Quick
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas;
| | - C L Heaps
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| | - J Hardy
- Large Animal Clinical Sciences, Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, Texas; and
| | - G A Laine
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| | - E Wilson
- Department of Medical Physiology, Texas A&M Health Science Center, Texas A&M University, College Station, Texas
| | - R H Stewart
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| |
Collapse
|
32
|
Bazigou E, Wilson JT, Moore JE. Primary and secondary lymphatic valve development: molecular, functional and mechanical insights. Microvasc Res 2014; 96:38-45. [PMID: 25086182 DOI: 10.1016/j.mvr.2014.07.008] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Revised: 07/17/2014] [Accepted: 07/22/2014] [Indexed: 01/27/2023]
Abstract
Fluid homeostasis in vertebrates critically relies on the lymphatic system forming a hierarchical network of lymphatic capillaries and collecting lymphatics, for the efficient drainage and transport of extravasated fluid back to the cardiovascular system. Blind-ended lymphatic capillaries employ specialized junctions and anchoring filaments to encourage a unidirectional flow of the interstitial fluid into the initial lymphatic vessels, whereas collecting lymphatics are responsible for the active propulsion of the lymph to the venous circulation via the combined action of lymphatic muscle cells and intraluminal valves. Here we describe recent findings on molecular and physical factors regulating the development and maturation of these two types of valves and examine their role in tissue-fluid homeostasis.
Collapse
Affiliation(s)
- Eleni Bazigou
- Department of Bioengineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK.
| | - John T Wilson
- Department of Bioengineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK
| | - James E Moore
- Department of Bioengineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK
| |
Collapse
|
33
|
Quick CM, Criscione JC, Kotiya A, Dongaonkar RM, Hardy J, Wilson E, Gashev AA, Laine GA, Stewart RH. Functional adaptation of bovine mesenteric lymphatic vessels to mesenteric venous hypertension. Am J Physiol Regul Integr Comp Physiol 2014; 306:R901-7. [PMID: 24671245 DOI: 10.1152/ajpregu.00185.2013] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Lymph flow is the primary mechanism for returning interstitial fluid to the blood circulation. Currently, the adaptive response of lymphatic vessels to mesenteric venous hypertension is not known. This study sought to determine the functional responses of postnodal mesenteric lymphatic vessels. We surgically occluded bovine mesenteric veins to create mesenteric venous hypertension to elevate mesenteric lymph flow. Three days after surgery, postnodal mesenteric lymphatic vessels from mesenteric venous hypertension (MVH; n = 7) and sham surgery (Sham; n = 6) group animals were evaluated and compared. Contraction frequency (MVH: 2.98 ± 0.75 min(-1); Sham: 5.42 ± 0.81 min(-1)) and fractional pump flow (MVH: 1.14 ± 0.30 min(-1); Sham: 2.39 ± 0.32 min(-1)) were significantly lower in the venous occlusion group. These results indicate that postnodal mesenteric lymphatic vessels adapt to mesenteric venous hypertension by reducing intrinsic contractile activity.
Collapse
Affiliation(s)
- Christopher M Quick
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; Department of Biomedical Engineering, Texas A&M University, College Station, Texas;
| | - John C Criscione
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Akhilesh Kotiya
- Department Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | | | - Joanne Hardy
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; Large Animal Clinical Sciences, Texas A&M University, College Station, Texas; and
| | - Emily Wilson
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; Systems Biology and Translational Medicine, Texas A&M Health Science Center, Temple, Texas
| | - Anatoliy A Gashev
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; Systems Biology and Translational Medicine, Texas A&M Health Science Center, Temple, Texas
| | - Glen A Laine
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| | - Randolph H Stewart
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| |
Collapse
|
34
|
Meens MJ, Sabine A, Petrova TV, Kwak BR. Connexins in lymphatic vessel physiology and disease. FEBS Lett 2014; 588:1271-7. [PMID: 24457200 DOI: 10.1016/j.febslet.2014.01.011] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2013] [Revised: 01/13/2014] [Accepted: 01/14/2014] [Indexed: 12/26/2022]
Abstract
Connexins are transmembrane proteins that form gap junction- and hemi-channels. Once inserted into the membrane, hemi-channels (connexons) allow for diffusion of ions and small molecules (<1 kDa) between the extracellular space and the cytosol. Gap junction channels allow diffusion of similar molecules between the cytoplasms of adjacent cells. The expression and function of connexins in blood vessels has been intensely studied in the last few decades. In contrast, only a few studies paid attention to lymphatic vessels; convincing in vivo data with respect to expression patterns of lymphatic connexins and their functional roles have only recently begun to emerge. Interestingly, mutations in connexin genes have been linked to diseases of lymphatic vasculature, most notably primary and secondary lymphedema. This review summarizes the available data regarding lymphatic connexins. More specifically it addresses (i) early studies aimed at presence of gap junction-like structures in lymphatic vessels, (ii) more recent studies focusing on lymphatic connexins using genetically engineered mice, and (iii) results of clinical studies that have reported lymphedema-linked mutations in connexin genes.
Collapse
Affiliation(s)
- Merlijn J Meens
- Department of Pathology and Immunology, University of Geneva, CH-1211 Geneva, Switzerland; Department of Internal Medicine - Cardiology, University of Geneva, CH-1211 Geneva, Switzerland
| | - Amélie Sabine
- Department of Oncology, University Hospital of Lausanne, 1066 Epalinges, Switzerland; Department of Biochemistry, University of Lausanne, 1066 Epalinges, Switzerland
| | - Tatiana V Petrova
- Department of Oncology, University Hospital of Lausanne, 1066 Epalinges, Switzerland; Department of Biochemistry, University of Lausanne, 1066 Epalinges, Switzerland; École Polytechnique Fédérale de Lausanne (EPFL), Swiss Institute for Experimental Cancer Research (ISREC), 1015 Lausanne, Switzerland
| | - Brenda R Kwak
- Department of Pathology and Immunology, University of Geneva, CH-1211 Geneva, Switzerland; Department of Internal Medicine - Cardiology, University of Geneva, CH-1211 Geneva, Switzerland.
| |
Collapse
|
35
|
Briggs Boedtkjer D, Rumessen J, Baandrup U, Skov Mikkelsen M, Telinius N, Pilegaard H, Aalkjaer C, Hjortdal V. Identification of interstitial Cajal-like cells in the human thoracic duct. Cells Tissues Organs 2012; 197:145-58. [PMID: 23147528 DOI: 10.1159/000342437] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/10/2012] [Indexed: 11/19/2022] Open
Abstract
Interstitial Cajal-like cells (ICLCs) are speculated to be pacemakers in smooth muscle tissues. While the human thoracic duct (TD) is spontaneously active, the origin of this activity is unknown. We hypothesized that ICLCs could be present in the TD and using histological techniques, immunohistochemistry and immunofluorescence we have investigated the presence of ICLCs, protein markers for ICLCs and the cellular morphology of the human TD. Transmission electron microscopy was employed to investigate ultrastructure. Methylene blue staining, calcium-dependent fluorophores and confocal microscopy were used to identify ICLCs in live tissue. Methylene blue stained cells with morphology suggestive of ICLCs in the TD. Immunoreactivity localized the ICLC protein markers c-kit, CD34 and vimentin to many cells and processes associated with smooth muscle cells (SMCs): coexpression of c-kit with vimentin or CD34 was observed in some cells. Electron microscopy analysis confirmed ICLCs as a major cell type of the human TD. Lymphatic ICLCs possess caveolae, dense bands, a patchy basal lamina, intermediate filaments and specific junctions to SMCs. ICLCs were ultrastructurally differentiable from other interstitial cells observed: fibroblasts, mast cells, macrophages and pericytes. Lymphatic ICLCs were localized to the subendothelial region of the wall as well as in intimate association with smooth muscle bundles throughout the media. ICLCs were morphologically distinct with multiple processes and also spindle shapes. Confocal imaging with calcium-dependent fluorophores corroborated cell morphology and localization observed in fixed tissues. Lymphatic ICLCs thus constitute a significant cell type of the human TD and physically interact with lymphatic SMCs.
Collapse
|
36
|
Abstract
We studied the relationship between the length and tension in isolated strips of the capsules of bovine mesenteric lymph nodes. The deformation-strain and radius-pressure relationships were established in the lymph node. The capsule possesses high distensibility, modulus of elasticity at optimal tension was 0.09×10(5) N/m2. Smooth muscle activation produces a 6-fold increase of modulus of elasticity. Maximum active stress in the capsule was recorded at a length of 1.1 L0 and maximal active pressure (4.5 cm H2O) at 0.9 L0.
Collapse
Affiliation(s)
- G I Lobov
- Laboratory for Circulatory Physiology, I. P. Pavlov Institute of Physiology, Russian Academy of Sciences, St. Petersburg, Russia.
| | | |
Collapse
|
37
|
Connexins in atherosclerosis. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES 2012; 1828:157-66. [PMID: 22609170 DOI: 10.1016/j.bbamem.2012.05.011] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2012] [Revised: 04/26/2012] [Accepted: 05/04/2012] [Indexed: 11/20/2022]
Abstract
Atherosclerosis, a chronic inflammatory disease of the vessel wall, involves multiple cell types of different origins, and complex interactions and signaling pathways between them. Autocrine and paracrine communication pathways provided by cytokines, chemokines, growth factors and lipid mediators are central to atherogenesis. However, it is becoming increasingly recognized that a more direct communication through both hemichannels and gap junction channels formed by connexins also plays an important role in atherosclerosis development. Three main connexins are expressed in cells involved in atherosclerosis: Cx37, Cx40 and Cx43. Cx37 is found in endothelial cells, monocytes/macrophages and platelets, Cx40 is predominantly an endothelial connexin, and Cx43 is found in a large variety of cells such as smooth muscle cells, resident and circulating leukocytes (neutrophils, dendritic cells, lymphocytes, activated macrophages, mast cells) and some endothelial cells. Here, we will systematically review the expression and function of connexins in cells and processes underlying atherosclerosis. This article is part of a Special Issue entitled: The Communicating junctions, roles and dysfunctions.
Collapse
|
38
|
Margaris KN, Black RA. Modelling the lymphatic system: challenges and opportunities. J R Soc Interface 2012; 9:601-12. [PMID: 22237677 PMCID: PMC3284143 DOI: 10.1098/rsif.2011.0751] [Citation(s) in RCA: 117] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2011] [Accepted: 12/12/2011] [Indexed: 11/12/2022] Open
Abstract
The lymphatic system is a vital part of the circulatory and immune systems, and plays an important role in homeostasis by controlling extracellular fluid volume and in combating infection. Nevertheless, there is a notable disparity in terms of research effort expended in relation to the treatment of lymphatic diseases in contrast to the cardiovascular system. While similarities to the cardiovascular system exist, there are considerable differences in their anatomy and physiology. This review outlines some of the challenges and opportunities for those engaged in modelling biological systems. The study of the lymphatic system is still in its infancy, the vast majority of the models presented in the literature to date having been developed since 2003. The number of distinct models and their variants are few in number, and only one effort has been made thus far to study the entire lymphatic network; elements of the lymphatic system such as the nodes, which act as pumps and reservoirs, have not been addressed by mathematical models. Clearly, more work will be necessary in combination with experimental verification in order to progress and update the knowledge on the function of the lymphatic system. As our knowledge and understanding of its function increase, new and more effective treatments of lymphatic diseases are bound to emerge.
Collapse
Affiliation(s)
- K N Margaris
- Department of Bioengineering, University of Strathclyde, 106 Rottenrow, Glasgow G4 0NW, UK.
| | | |
Collapse
|
39
|
Finegold DN, Baty CJ, Knickelbein KZ, Perschke S, Noon SE, Campbell D, Karlsson JM, Huang D, Kimak MA, Lawrence EC, Feingold E, Meriney SD, Brufsky AM, Ferrell RE. Connexin 47 mutations increase risk for secondary lymphedema following breast cancer treatment. Clin Cancer Res 2012; 18:2382-90. [PMID: 22351697 DOI: 10.1158/1078-0432.ccr-11-2303] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE Secondary lymphedema is a frequent complication of breast cancer associated with surgery, chemotherapy, or radiation following breast cancer treatment. The potential contribution of genetic susceptibility to risk of developing secondary lymphedema following surgical trauma, radiation, and other tissue insults has not been studied. EXPERIMENTAL DESIGN To determine whether women with breast cancer and secondary lymphedema had mutations in candidate lymphedema genes, we undertook a case-control study of 188 women diagnosed with breast cancer recruited from the University of Pittsburgh Breast Cancer Program (http://www.upmccancercenter.com/breast/index.cfm) between 2000 and 2010. Candidate lymphedema genes, GJC2 (encoding connexin 47 [Cx47]), FOXC2, HGF, MET, and FLT4 (encoding VEGFR3), were sequenced for mutation. Bioinformatics analysis and in vitro functional assays were used to confirm significance of novel mutations. RESULTS Cx47 mutations were identified in individuals having secondary lymphedema following breast cancer treatment but not in breast cancer controls or normal women without breast cancer. These novel mutations are dysfunctional as assessed through in vitro assays and bioinformatics analysis and provide evidence that altered gap junction function leads to lymphedema. CONCLUSIONS Our findings challenge the view that secondary lymphedema is solely due to mechanical trauma and support the hypothesis that genetic susceptibility is an important risk factor for secondary lymphedema. A priori recognition of genetic risk (i) raises the potential for early detection and intervention for a high-risk group and (ii) allows the possibility of altering surgical approach and/or chemo- and radiation therapy, or direct medical treatment of secondary lymphedema with novel connexin-modifying drugs.
Collapse
Affiliation(s)
- David N Finegold
- Department of Pediatrics, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania 15261, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Nepiyushchikh ZV, Chakraborty S, Wang W, Davis MJ, Zawieja DC, Muthuchamy M. Differential effects of myosin light chain kinase inhibition on contractility, force development and myosin light chain 20 phosphorylation of rat cervical and thoracic duct lymphatics. J Physiol 2011; 589:5415-29. [PMID: 21930597 DOI: 10.1113/jphysiol.2011.218446] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
The intrinsic contractile activity of lymphatics varies in different regions of the body. We have previously shown that cervical lymphatics possess an inherently higher frequency but lower tone at a given pressure when compared to thoracic duct lymphatics. However, the molecular mechanisms modulating the contractile characteristics of these lymphatics are not well understood. Since myosin light chain 20 (MLC(20)) phosphorylation appears to underlie the tonic component of lymphatic contraction, we hypothesized that the thoracic duct would be more sensitive to the modulation of MLC(20) phosphorylation when compared to cervical lymphatics. To test our hypothesis, the contractile activities and MLC(20) phosphorylation of thoracic duct and cervical lymphatics were determined in the absence or presence of the specific myosin light chain kinase (MLCK) inhibitor ML-7 under both isobaric and isometric conditions. Addition of ML-7 at each concentration tested led to a decrease in tone in both vessel types. While ML-7 (10(-6) m) significantly reduced the phasic contraction frequency of cervical lymphatics, it completely stopped phasic contractions of thoracic duct at that concentration. Under isometric conditions the active peak and plateau components of tension were both significantly higher in thoracic duct compared to cervical lymphatics. ML-7 (10(-5) m) significantly decreased both the active peak and plateau tensions of thoracic duct, whereas only the active peak tension of cervical lymphatics was decreased. In thoracic duct MLC(20) di-phosphorylation, but not mono-phosphorylation, was significantly decreased with increasing transmural pressure, whereas in cervical vessels only at the higher pressures tested did MLC(20) di-phosphorylation decrease. ML-7 treatment of the thoracic duct caused a significant decrease in both the mono- and di-phosphorylated forms of MLC(20). However, in cervical vessels ML-7 treatment produced an increase in the mono-phosphorylated MLC(20) form while di-phosphorylated MLC(20) was significantly decreased. These data indicate that thoracic duct has an enhanced sensitivity to MLCK inhibition when compared to cervical lymphatics and while the status of the mono- and di-phosphorylation forms of MLC(20) affects both tonic and phasic components of lymphatic contractions, the pressure-dependent changes in tonic contractions are modulated by the status of the di-phosphorylation of MLC(20) in the lymphatics.
Collapse
Affiliation(s)
- Zhanna V Nepiyushchikh
- Department of Systems Biology and Translational Medicine, Cardiovascular Research Institute, Division of Lymphatic Biology, Texas A&M Health Science Center College of Medicine, 336 Reynolds Medical Building, College Station, TX 77843, USA
| | | | | | | | | | | |
Collapse
|
41
|
Bohlen HG, Gasheva OY, Zawieja DC. Nitric oxide formation by lymphatic bulb and valves is a major regulatory component of lymphatic pumping. Am J Physiol Heart Circ Physiol 2011; 301:H1897-906. [PMID: 21890688 DOI: 10.1152/ajpheart.00260.2011] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Microscopic lymphatics produce nitric oxide (NO) during contraction as flow shear activates the endothelial cells. The valve leaflets and bulbous valve housing contain a large amount of endothelial nitric oxide synthase (eNOS) due both to many endothelial cells and increased expression of eNOS. Direct NO measurements indicate the valve area has a 30-50% higher NO concentration ([NO]) than tubular regions although both regions generate equivalent relative increases in [NO] with each contraction. We hypothesize that 1) the greater eNOS and [NO] of the bulb region would have greater effects to lower pumping activity of the overall lymphatic than occurs in tubular regions and 2), the elevated [NO] in the bulb region may be because of high NO production in the valve leaflets that diffuses to the wall of the bulb. Measurement of [NO] with a micropipette inside the lymphatic bulb revealed the valve leaflets generate ~50% larger [NO] than the bulb wall in the in vivo rat mesenteric lymphatics. The valves add NO to the lymph that quickly diffuses to the bulb wall. Bradykinin locally released iontophoretically from a micropipette on both bulbs and tubes increased the [NO] in a dose-dependent manner up to ~50%, demonstrating agonist activation of the NO pathway. However, pumping output determined by contraction frequency and stroke volume decreased much more for the bulb than tubular areas in response to the bradykinin. In effect, NO generation by the bulb area and its valves limits the pumped flow of the total lymphatic by lowering frequency and stroke volume of individual contractions.
Collapse
Affiliation(s)
- H Glenn Bohlen
- Department of Cellular and Integrative Physiology, Indiana University Medical School, Indianapolis, IN 46202, USA.
| | | | | |
Collapse
|
42
|
Kanady JD, Simon AM. Lymphatic communication: connexin junction, what's your function? Lymphology 2011; 44:95-102. [PMID: 22165579 PMCID: PMC3520433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
This article reviews recent findings on expression and function of connexin proteins--the structural subunits of gap junction intercellular channels in the lymphatic vasculature--both during development and in the mature lymphatic vessel. Highlighted in particular are recent mouse connexin knockout studies which show that connexins are crucial for normal lymphatic development. We discuss, in general terms, both channel-dependent as well as channel-independent functions of connexins and raise some of the many unanswered questions about the mechanism(s) of action and physiological roles of connexins in the lymphatic vasculature.
Collapse
Affiliation(s)
| | - Alexander M. Simon
- Author for correspondence: Alexander M. Simon, Ph.D., Department of Physiology, University of Arizona, PO Box 245051, Tucson, AZ 85724, USA, Phone: 520-621-9778, Fax: 520-626-2383,
| |
Collapse
|
43
|
Abstract
The recent advances in our understanding of lymphatic physiology and the role of the lymphatics in actively regulating fluid balance, lipid transport, and immune cell trafficking has been furthered in part through innovations in imaging, tissue engineering, quantitative biology, biomechanics, and computational modeling. Interdisciplinary and bioengineering approaches will continue to be crucial to the progression of the field, given that lymphatic biology and function are intimately woven with the local microenvironment and mechanical loads experienced by the vessel. This is particularly the case in lymphatic diseases such as lymphedema where the microenvironment can be drastically altered by tissue fibrosis and adipocyte accumulation. In this review we will highlight contributions engineering and mechanics have made to lymphatic physiology and will discuss areas that will be important for future research.
Collapse
|
44
|
Kanady JD, Dellinger MT, Munger SJ, Witte MH, Simon AM. Connexin37 and Connexin43 deficiencies in mice disrupt lymphatic valve development and result in lymphatic disorders including lymphedema and chylothorax. Dev Biol 2011; 354:253-66. [PMID: 21515254 PMCID: PMC3134316 DOI: 10.1016/j.ydbio.2011.04.004] [Citation(s) in RCA: 133] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2011] [Revised: 04/06/2011] [Accepted: 04/08/2011] [Indexed: 12/31/2022]
Abstract
Intraluminal valves are required for the proper function of lymphatic collecting vessels and large lymphatic trunks like the thoracic duct. Despite recent progress in the study of lymphvasculogenesis and lymphangiogenesis, the molecular mechanisms controlling the morphogenesis of lymphatic valves remain poorly understood. Here, we report that gap junction proteins, or connexins (Cxs), are required for lymphatic valvulogenesis. Cx37 and Cx43 are expressed early in mouse lymphatic development in the jugular lymph sacs, and later in development these Cxs become enriched and differentially expressed by lymphatic endothelial cells on the upstream and downstream sides of the valves. Specific deficiencies of Cx37 and Cx43 alone or in combination result in defective valve formation in lymphatic collecting vessels, lymphedema, and chylothorax. We also show that Cx37 regulates jugular lymph sac size and that both Cx37 and Cx43 are required for normal thoracic duct development, including valve formation. Another Cx family member, Cx47, whose human analog is mutated in some families with lymphedema, is also highly enriched in a subset of endothelial cells in lymphatic valves. Mechanistically, we present data from Foxc2-/- embryos suggesting that Cx37 may be a target of regulation by Foxc2, a transcription factor that is mutated in human lymphedema-distichiasis syndrome. These results show that at least three Cxs are expressed in the developing lymphatic vasculature and, when defective, are associated with clinically manifest lymphatic disorders in mice and man.
Collapse
Affiliation(s)
- John D. Kanady
- Department of Physiology, University of Arizona, Tucson, AZ 85724, USA
| | - Michael T. Dellinger
- Department of Molecular and Cellular Biology, University of Arizona, Tucson, AZ 85724, USA
| | | | - Marlys H. Witte
- Department of Surgery, University of Arizona, Tucson, AZ 85724, USA
| | | |
Collapse
|
45
|
Kwon S, Sevick-Muraca EM. Mouse phenotyping with near-infrared fluorescence lymphatic imaging. BIOMEDICAL OPTICS EXPRESS 2011; 2:1403-1411. [PMID: 21698004 PMCID: PMC3114209 DOI: 10.1364/boe.2.001403] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2011] [Revised: 04/20/2011] [Accepted: 04/29/2011] [Indexed: 05/27/2023]
Abstract
We demonstrate the ability to non-invasively and quantitatively image lymphatic architecture and contractile function using dynamic near-infrared (NIR) fluorescence imaging with injection of indocyanine green in normal and transgenic mice. Unlike normal mice, which showed well defined lymphatic drainage patterns and orthograde propagation of contraction waves, we observed tortuous and mispatterned lymphatic vessels and persistent retrograde lymph flow in mice with deficiency in Prox1, a transcription factor essential for lymphatic vascular development. NIR fluorescence imaging provides a method for quantifying lymphatic function for future studies designed to discern differences in lymphatic function in murine models of human lymphatic disease.
Collapse
|
46
|
Bertram CD, Macaskill C, Moore JE. Simulation of a chain of collapsible contracting lymphangions with progressive valve closure. J Biomech Eng 2011; 133:011008. [PMID: 21186898 DOI: 10.1115/1.4002799] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The aim of this investigation was to achieve the first step toward a comprehensive model of the lymphatic system. A numerical model has been constructed of a lymphatic vessel, consisting of a short series chain of contractile segments (lymphangions) and of intersegmental valves. The changing diameter of a segment governs the difference between the flows through inlet and outlet valves and is itself governed by a balance between transmural pressure and passive and active wall properties. The compliance of segments is maximal at intermediate diameters and decreases when the segments are subject to greatly positive or negative transmural pressure. Fluid flow is the result of time-varying active contraction causing diameter to reduce and is limited by segmental viscous and valvular resistance. The valves effect a smooth transition from low forward-flow resistance to high backflow resistance. Contraction occurs sequentially in successive lymphangions in the forward-flow direction. The behavior of chains of one to five lymphangions was investigated by means of pump function curves, with variation of valve opening parameters, maximum contractility, lymphangion size gradation, number of lymphangions, and phase delay between adjacent lymphangion contractions. The model was reasonably robust numerically, with mean flow-rate generally reducing as adverse pressure was increased. Sequential contraction was found to be much more efficient than synchronized contraction. At the highest adverse pressures, pumping failed by one of two mechanisms, depending on parameter settings: either mean leakback flow exceeded forward pumping or contraction failed to open the lymphangion outlet valve. Maximum pressure and maximum flow-rate were both sensitive to the contractile state; maximum pressure was also determined by the number of lymphangions in series. Maximum flow-rate was highly sensitive to the transmural pressure experienced by the most upstream lymphangions, suggesting that many feeding lymphatics would be needed to supply one downstream lymphangion chain pumping at optimal transmural pressure.
Collapse
Affiliation(s)
- C D Bertram
- School of Mathematics and Statistics, University of Sydney, New South Wales 2006, Australia
| | | | | |
Collapse
|
47
|
Akl TJ, Nepiyushchikh ZV, Gashev AA, Zawieja DC, Cot GL. Measuring contraction propagation and localizing pacemaker cells using high speed video microscopy. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:026016. [PMID: 21361700 PMCID: PMC3065345 DOI: 10.1117/1.3544512] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2010] [Revised: 12/30/2010] [Accepted: 01/03/2011] [Indexed: 05/30/2023]
Abstract
Previous studies have shown the ability of many lymphatic vessels to contract phasically to pump lymph. Every lymphangion can act like a heart with pacemaker sites that initiate the phasic contractions. The contractile wave propagates along the vessel to synchronize the contraction. However, determining the location of the pacemaker sites within these vessels has proven to be very difficult. A high speed video microscopy system with an automated algorithm to detect pacemaker location and calculate the propagation velocity, speed, duration, and frequency of the contractions is presented in this paper. Previous methods for determining the contractile wave propagation velocity manually were time consuming and subject to errors and potential bias. The presented algorithm is semiautomated giving objective results based on predefined criteria with the option of user intervention. The system was first tested on simulation images and then on images acquired from isolated microlymphatic mesenteric vessels. We recorded contraction propagation velocities around 10 mm/s with a shortening speed of 20.4 to 27.1 μm/s on average and a contraction frequency of 7.4 to 21.6 contractions/min. The simulation results showed that the algorithm has no systematic error when compared to manual tracking. The system was used to determine the pacemaker location with a precision of 28 μm when using a frame rate of 300 frames per second.
Collapse
Affiliation(s)
- Tony J Akl
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas 77843, USA.
| | | | | | | | | |
Collapse
|
48
|
|
49
|
Chakraborty S, Zawieja S, Wang W, Zawieja DC, Muthuchamy M. Lymphatic system: a vital link between metabolic syndrome and inflammation. Ann N Y Acad Sci 2010; 1207 Suppl 1:E94-102. [PMID: 20961312 DOI: 10.1111/j.1749-6632.2010.05752.x] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Metabolic syndrome is defined by a cluster of different metabolic risk factors that include overall and central obesity, elevated fasting glucose levels, dyslipidemia, hypertension, and intimal atherogenesis. Metabolic syndrome leads to increased risk for the development of type 2 diabetes and cardiovascular disease (e.g., heart disease and stroke). The exacerbated progression of metabolic syndrome to cardiovascular disease has lead to intense study of the physiological ramifications of metabolic syndrome on the blood vasculature. These studies have particularly focused on the signaling and architectural alterations that manifest in hypertension and atherosclerosis. However, despite the overlap of metabolic syndrome pathology with lymphatic function, tangent effects on the lymphatic system have not been extensively documented. In this review, we discuss the current status of metabolic syndrome and provide evidence for, and the remaining challenges in studying, the connections among the lymphatic system, lipid transport, obesity, insulin resistance, and general inflammation.
Collapse
Affiliation(s)
- Sanjukta Chakraborty
- Division of Lymphatic Biology, Department of Systems Biology and Translational Medicine, Cardiovascular Research Institute, Texas A&M Health Science Center College of Medicine, College Station, Texas 77843, USA
| | | | | | | | | |
Collapse
|
50
|
Lobov GI, Pan'kova MN, Dvoretsky DP, Sergeev IV. Characteristic of the active and passive mechanical properties of the lymph node capsule. DOKLADY BIOLOGICAL SCIENCES : PROCEEDINGS OF THE ACADEMY OF SCIENCES OF THE USSR, BIOLOGICAL SCIENCES SECTIONS 2010; 434:310-312. [PMID: 20963651 DOI: 10.1134/s0012496610050054] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2010] [Indexed: 05/30/2023]
Affiliation(s)
- G I Lobov
- Pavlov Institute of Physiology, Russian Academy of Sciences, St. Petersburg, Russia
| | | | | | | |
Collapse
|