• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4609580)   Today's Articles (214)   Subscriber (49378)
For: Avanzini A. A computational procedure for prediction of structural effects of edge-to-edge repair on mitral valve. J Biomech Eng 2008;130:031015. [PMID: 18532864 DOI: 10.1115/1.2913235] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Number Cited by Other Article(s)
1
Beating heart implantation of transventricular artificial cordae: how can access site selection and leaflet insertion improve mitral regurgitation correction? Med Eng Phys 2022;101:103773. [DOI: 10.1016/j.medengphy.2022.103773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 12/04/2021] [Accepted: 02/09/2022] [Indexed: 11/19/2022]
2
Toma M, Einstein DR, Kohli K, Caroll SL, Bloodworth CH, Cochran RP, Kunzelman KS, Yoganathan AP. Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations. BIOLOGY 2020;9:biology9070173. [PMID: 32708356 PMCID: PMC7407795 DOI: 10.3390/biology9070173] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Revised: 07/13/2020] [Accepted: 07/16/2020] [Indexed: 11/22/2022]
3
The neochord mitral valve repair procedure: Numerical simulation of different neochords tensioning protocols. Med Eng Phys 2019;74:121-128. [DOI: 10.1016/j.medengphy.2019.09.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Revised: 08/01/2019] [Accepted: 09/16/2019] [Indexed: 01/09/2023]
4
Timek TA. Fibbin' under pressure. J Thorac Cardiovasc Surg 2019;157:930-931. [PMID: 33198015 DOI: 10.1016/j.jtcvs.2018.09.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Accepted: 09/11/2018] [Indexed: 11/25/2022]
5
Gao H, Qi N, Feng L, Ma X, Danton M, Berry C, Luo X. Modelling mitral valvular dynamics-current trend and future directions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017;33:e2858. [PMID: 27935265 PMCID: PMC5697636 DOI: 10.1002/cnm.2858] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 09/30/2016] [Accepted: 11/26/2016] [Indexed: 05/19/2023]
6
Skornitzke S, Schummers G, Schreckenberg M, Ender J, Eibel S, Bungartz HJ, Kauczor HU, Stiller W. Mass-spring systems for simulating mitral valve repair using 3D ultrasound images. Comput Med Imaging Graph 2015;45:26-35. [PMID: 26241162 DOI: 10.1016/j.compmedimag.2015.07.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 05/08/2015] [Accepted: 07/13/2015] [Indexed: 11/25/2022]
7
Chandran KB, Kim H. Computational mitral valve evaluation and potential clinical applications. Ann Biomed Eng 2014;43:1348-62. [PMID: 25134487 DOI: 10.1007/s10439-014-1094-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2014] [Accepted: 08/09/2014] [Indexed: 01/15/2023]
8
Sun W, Martin C, Pham T. Computational modeling of cardiac valve function and intervention. Annu Rev Biomed Eng 2014;16:53-76. [PMID: 24819475 DOI: 10.1146/annurev-bioeng-071813-104517] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
9
Premeasured neochordae loop maker: a new technology in mitral valve repair. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2013;8:443-9. [PMID: 24356435 DOI: 10.1097/imi.0000000000000030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
10
Ghavidel AA, Samiei N, Javadikasgari H, Bashirpour K. Premeasured Neochordae Loop Maker. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2013. [DOI: 10.1177/155698451300800611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
11
Pham T, Sun W. Material properties of aged human mitral valve leaflets. J Biomed Mater Res A 2013;102:2692-703. [PMID: 24039052 DOI: 10.1002/jbm.a.34939] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Revised: 08/01/2013] [Accepted: 08/26/2013] [Indexed: 11/08/2022]
12
Rabbah JPM, Saikrishnan N, Siefert AW, Santhanakrishnan A, Yoganathan AP. Mechanics of healthy and functionally diseased mitral valves: a critical review. J Biomech Eng 2013;135:021007. [PMID: 23445052 DOI: 10.1115/1.4023238] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
13
Mansi T, Voigt I, Georgescu B, Zheng X, Mengue EA, Hackl M, Ionasec RI, Noack T, Seeburger J, Comaniciu D. An integrated framework for finite-element modeling of mitral valve biomechanics from medical images: application to MitralClip intervention planning. Med Image Anal 2012;16:1330-46. [PMID: 22766456 DOI: 10.1016/j.media.2012.05.009] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2012] [Revised: 04/21/2012] [Accepted: 05/18/2012] [Indexed: 11/17/2022]
14
Lau K, Díaz-Zuccarini V, Scambler P, Burriesci G. Fluid–structure interaction study of the edge-to-edge repair technique on the mitral valve. J Biomech 2011;44:2409-17. [DOI: 10.1016/j.jbiomech.2011.06.030] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2011] [Revised: 06/02/2011] [Accepted: 06/26/2010] [Indexed: 10/17/2022]
15
Stevanella M, Krishnamurthy G, Votta E, Swanson JC, Redaelli A, Ingels NB. Mitral leaflet modeling: Importance of in vivo shape and material properties. J Biomech 2011;44:2229-35. [DOI: 10.1016/j.jbiomech.2011.06.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2011] [Revised: 05/02/2011] [Accepted: 06/03/2011] [Indexed: 10/18/2022]
16
Avanzini A, Donzella G, Libretti L. Functional and structural effects of percutaneous edge-to-edge double-orifice repair under cardiac cycle in comparison with suture repair. Proc Inst Mech Eng H 2011;225:959-71. [DOI: 10.1177/0954411911414803] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
17
Stevanella M, Maffessanti F, Conti CA, Votta E, Arnoldi A, Lombardi M, Parodi O, Caiani EG, Redaelli A. Mitral Valve Patient-Specific Finite Element Modeling from Cardiac MRI: Application to an Annuloplasty Procedure. Cardiovasc Eng Technol 2011. [DOI: 10.1007/s13239-010-0032-4] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
18
Mohammadi H, Mequanint K. Prosthetic aortic heart valves: modeling and design. Med Eng Phys 2010;33:131-47. [PMID: 20971672 DOI: 10.1016/j.medengphy.2010.09.017] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2010] [Revised: 07/19/2010] [Accepted: 09/24/2010] [Indexed: 10/18/2022]
19
Xu C, Brinster CJ, Jassar AS, Vergnat M, Eperjesi TJ, Gorman RC, Gorman JH, Jackson BM. A novel approach to in vivo mitral valve stress analysis. Am J Physiol Heart Circ Physiol 2010;299:H1790-4. [PMID: 20952665 DOI: 10.1152/ajpheart.00370.2010] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
20
Hu Y, Shi L, Parameswaran S, Smirnov S, He Z. Left Ventricular Vortex Under Mitral Valve Edge-to-Edge Repair. Cardiovasc Eng Technol 2010;1:235-243. [PMID: 21666755 DOI: 10.1007/s13239-010-0022-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
21
Role of Computational Simulations in Heart Valve Dynamics and Design of Valvular Prostheses. Cardiovasc Eng Technol 2010;1:18-38. [PMID: 20606715 DOI: 10.1007/s13239-010-0002-x] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
22
He Z, Gao B, Bhattacharya S, Harrist T, Mathew S, Sun W. In Vitro Stretches of the Mitral Valve Anterior Leaflet Under Edge-to-Edge Repair Condition. J Biomech Eng 2009;131:111012. [DOI: 10.1115/1.4000111] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA