Beating heart implantation of transventricular artificial cordae: how can access site selection and leaflet insertion improve mitral regurgitation correction? Med Eng Phys 2022; 101:103773. [DOI: 10.1016/j.medengphy.2022.103773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 12/04/2021] [Accepted: 02/09/2022] [Indexed: 11/19/2022]
|
2
|
Toma M, Einstein DR, Kohli K, Caroll SL, Bloodworth CH, Cochran RP, Kunzelman KS, Yoganathan AP. Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations. BIOLOGY 2020; 9:biology9070173. [PMID: 32708356 PMCID: PMC7407795 DOI: 10.3390/biology9070173] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Revised: 07/13/2020] [Accepted: 07/16/2020] [Indexed: 11/22/2022]
Abstract
Edge-to-edge repair for mitral valve regurgitation is being increasingly performed in high-surgical risk patients using minimally invasive mitral clipping devices. Known procedural complications include chordal rupture and mitral leaflet perforation. Hence, it is important to quantitatively evaluate the effect of edge-to-edge repair on chordal integrity. in this study, we employ a computational mitral valve model to simulate functional mitral regurgitation (FMR) by creating papillary muscle displacement. Edge-to-edge repair is then modeled by simulated coaptation of the mid portion of the mitral leaflets. in the setting of simulated FMR, edge-to-edge repair was shown to sustain low regurgitant orifice area, until a two fold increase in the inter-papillary muscle distance as compared to the normal mitral valve. Strain in the chordae was evaluated near the papillary muscles and the leaflets. Following edge-to-edge repair, strain near the papillary muscles did not significantly change relative to the unrepaired valve, while strain near the leaflets increased significantly relative to the unrepaired valve. These data demonstrate the potential for computational simulations to aid in the pre-procedural evaluation of possible complications such as chordal rupture and leaflet perforation following percutaneous edge-to-edge repair.
Collapse
Affiliation(s)
- Milan Toma
- Department of Osteopathic Manipulative Medicine, College of Osteopathic Medicine, New York Institute of Technology, Old Westbury Campus, Northern Boulevard, Old Westbury, NY 11568-8000, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, 387 Technology Circle, Atlanta, GA 30313-2412, USA; (K.K.); (S.L.C.); (C.H.B.IV); (A.P.Y.)
- Correspondence:
| | - Daniel R. Einstein
- Department of Mechanical Engineering, St. Martin’s University, 5000 Abbey Way SE, Lacey, WA 98503, USA;
| | - Keshav Kohli
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, 387 Technology Circle, Atlanta, GA 30313-2412, USA; (K.K.); (S.L.C.); (C.H.B.IV); (A.P.Y.)
| | - Sheridan L. Caroll
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, 387 Technology Circle, Atlanta, GA 30313-2412, USA; (K.K.); (S.L.C.); (C.H.B.IV); (A.P.Y.)
| | - Charles H. Bloodworth
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, 387 Technology Circle, Atlanta, GA 30313-2412, USA; (K.K.); (S.L.C.); (C.H.B.IV); (A.P.Y.)
| | - Richard P. Cochran
- Department of Mechanical Engineering, University of Maine, 219 Boardman Hall, Orono, ME 04469-5711, USA; (R.P.C.); (K.S.K.)
| | - Karyn S. Kunzelman
- Department of Mechanical Engineering, University of Maine, 219 Boardman Hall, Orono, ME 04469-5711, USA; (R.P.C.); (K.S.K.)
| | - Ajit P. Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, 387 Technology Circle, Atlanta, GA 30313-2412, USA; (K.K.); (S.L.C.); (C.H.B.IV); (A.P.Y.)
| |
Collapse
|
3
|
The neochord mitral valve repair procedure: Numerical simulation of different neochords tensioning protocols. Med Eng Phys 2019; 74:121-128. [DOI: 10.1016/j.medengphy.2019.09.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Revised: 08/01/2019] [Accepted: 09/16/2019] [Indexed: 01/09/2023]
|
4
|
Timek TA. Fibbin' under pressure. J Thorac Cardiovasc Surg 2019; 157:930-931. [PMID: 33198015 DOI: 10.1016/j.jtcvs.2018.09.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Accepted: 09/11/2018] [Indexed: 11/25/2022]
Affiliation(s)
- Tomasz A Timek
- Division of Cardiothoracic Surgery, Spectrum Health, Grand Rapids, Mich; Michigan State University College of Human Medicine, Grand Rapids, Mich.
| |
Collapse
|
5
|
Gao H, Qi N, Feng L, Ma X, Danton M, Berry C, Luo X. Modelling mitral valvular dynamics-current trend and future directions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017; 33:e2858. [PMID: 27935265 PMCID: PMC5697636 DOI: 10.1002/cnm.2858] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 09/30/2016] [Accepted: 11/26/2016] [Indexed: 05/19/2023]
Abstract
Dysfunction of mitral valve causes morbidity and premature mortality and remains a leading medical problem worldwide. Computational modelling aims to understand the biomechanics of human mitral valve and could lead to the development of new treatment, prevention and diagnosis of mitral valve diseases. Compared with the aortic valve, the mitral valve has been much less studied owing to its highly complex structure and strong interaction with the blood flow and the ventricles. However, the interest in mitral valve modelling is growing, and the sophistication level is increasing with the advanced development of computational technology and imaging tools. This review summarises the state-of-the-art modelling of the mitral valve, including static and dynamics models, models with fluid-structure interaction, and models with the left ventricle interaction. Challenges and future directions are also discussed.
Collapse
Affiliation(s)
- Hao Gao
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | - Nan Qi
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | - Liuyang Feng
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | | | - Mark Danton
- Department of Cardiac SurgeryRoyal Hospital for ChildrenGlasgowUK
| | - Colin Berry
- Institute of Cardiovascular and Medical SciencesUniversity of GlasgowUK
| | - Xiaoyu Luo
- School of Mathematics and StatisticsUniversity of GlasgowUK
| |
Collapse
|
6
|
Skornitzke S, Schummers G, Schreckenberg M, Ender J, Eibel S, Bungartz HJ, Kauczor HU, Stiller W. Mass-spring systems for simulating mitral valve repair using 3D ultrasound images. Comput Med Imaging Graph 2015; 45:26-35. [PMID: 26241162 DOI: 10.1016/j.compmedimag.2015.07.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 05/08/2015] [Accepted: 07/13/2015] [Indexed: 11/25/2022]
Abstract
Mitral valve (MV) diseases are among the most common types of heart diseases, while heart diseases are the most common cause of death worldwide. MV repair surgery is connected to higher survival rates and fewer complications than the total replacement of the MV, but MV repair requires extensive patient-specific therapy planning. The simulation of MV repair with a patient-specific model could help to optimize surgery results and make MV repair available to more patients. However, current patient-specific simulations are difficult to transfer to clinical application because of time-constraints or prohibitive requirements on the resolution of the image data. As one possible solution to the problem of patient-specific MV modeling, we present a mass-spring MV model based on 3D transesophageal echocardiographic (TEE) images already routinely acquired for MV repair therapy planning. Our novel approach to the rest-length estimation of springs allows us to model the global support of the MV leaflets through the chordae tendinae without the need for high-resolution image data. The model is used to simulate MV annuloplasty for five patients undergoing MV repair, and the simulated results are compared to post-surgical TEE images. The comparison shows that our model is able to provide a qualitative estimate of annuloplasty surgery. In addition, the data suggests that the model might also be applied to simulating the implantation of artificial chordae.
Collapse
Affiliation(s)
- Stephan Skornitzke
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany; TomTec Imaging Systems GmbH, Unterschleißheim, Germany.
| | | | | | - Jörg Ender
- Department of Anesthesiology and Intensive Care Medicine II, Leipzig Heart Center, University of Leipzig, Leipzig, Germany
| | - Sarah Eibel
- Department of Anesthesiology and Intensive Care Medicine II, Leipzig Heart Center, University of Leipzig, Leipzig, Germany
| | | | - Hans-Ulrich Kauczor
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Wolfram Stiller
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| |
Collapse
|
7
|
Chandran KB, Kim H. Computational mitral valve evaluation and potential clinical applications. Ann Biomed Eng 2014; 43:1348-62. [PMID: 25134487 DOI: 10.1007/s10439-014-1094-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2014] [Accepted: 08/09/2014] [Indexed: 01/15/2023]
Abstract
The mitral valve (MV) apparatus consists of the two asymmetric leaflets, the saddle-shaped annulus, the chordae tendineae, and the papillary muscles. MV function over the cardiac cycle involves complex interaction between the MV apparatus components for efficient blood circulation. Common diseases of the MV include valvular stenosis, regurgitation, and prolapse. MV repair is the most popular and most reliable surgical treatment for early MV pathology. One of the unsolved problems in MV repair is to predict the optimal repair strategy for each patient. Although experimental studies have provided valuable information to improve repair techniques, computational simulations are increasingly playing an important role in understanding the complex MV dynamics, particularly with the availability of patient-specific real-time imaging modalities. This work presents a review of computational simulation studies of MV function employing finite element structural analysis and fluid-structure interaction approach reported in the literature to date. More recent studies towards potential applications of computational simulation approaches in the assessment of valvular repair techniques and potential pre-surgical planning of repair strategies are also discussed. It is anticipated that further advancements in computational techniques combined with the next generations of clinical imaging modalities will enable physiologically more realistic simulations. Such advancement in imaging and computation will allow for patient-specific, disease-specific, and case-specific MV evaluation and virtual prediction of MV repair.
Collapse
Affiliation(s)
- Krishnan B Chandran
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, 52242, USA
| | | |
Collapse
|
8
|
Abstract
In the past two decades, major advances have been made in the clinical evaluation and treatment of valvular heart disease owing to the advent of noninvasive cardiac imaging modalities. In clinical practice, valvular disease evaluation is typically performed on two-dimensional (2D) images, even though most imaging modalities offer three-dimensional (3D) volumetric, time-resolved data. Such 3D data offer researchers the possibility to reconstruct the 3D geometry of heart valves at a patient-specific level. When these data are integrated with computational models, native heart valve biomechanical function can be investigated, and preoperative planning tools can be developed. In this review, we outline the advances in valve geometry reconstruction, tissue property modeling, and loading and boundary definitions for the purpose of realistic computational structural analysis of cardiac valve function and intervention.
Collapse
Affiliation(s)
- Wei Sun
- Tissue Mechanics Lab, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30313;
| | | | | |
Collapse
|
9
|
Premeasured neochordae loop maker: a new technology in mitral valve repair. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2013; 8:443-9. [PMID: 24356435 DOI: 10.1097/imi.0000000000000030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The exact length of neochordae loops plays the major role in the success of mitral valve repair. The Neochordae Loop Maker is a novel device that models the left ventricular structure in an individual patient. Preoperative transthoracic echocardiography is used to identify the geometry of each papillary muscle and set up the device for the patient. All required neochordae loops are made in the operating room before initiating the cardiopulmonary bypass. In the calibration phase, seven consecutive patients who were candidates for mitral valve replacement underwent transthoracic echocardiography. The device was set up for each patient, and the length of their normal chordae and their respective neochordae was compared by the Bland-Altman analysis. From seven excised mitral valves, 21 chordae were considered normal (gold standard). The length of these gold standards (1.92 ± 0.67 cm) and their respective neochordae (1.93 ± 0.69 cm) showed agreement by the Bland-Altman analysis. The proposed technology showed satisfactory preliminary results in creating the premeasured neochorda loops inasmuch as it reduced the complexity of minimally invasive surgeries.
Collapse
|
10
|
Ghavidel AA, Samiei N, Javadikasgari H, Bashirpour K. Premeasured Neochordae Loop Maker. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2013. [DOI: 10.1177/155698451300800611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Alireza Alizadeh Ghavidel
- Heart Valve Disease Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Niloofar Samiei
- Heart Valve Disease Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Hoda Javadikasgari
- Heart Valve Disease Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Kamiar Bashirpour
- Mechanical Engineering Department, Amirkabir University of Technology, Tehran, Iran
| |
Collapse
|
11
|
Pham T, Sun W. Material properties of aged human mitral valve leaflets. J Biomed Mater Res A 2013; 102:2692-703. [PMID: 24039052 DOI: 10.1002/jbm.a.34939] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Revised: 08/01/2013] [Accepted: 08/26/2013] [Indexed: 11/08/2022]
Abstract
This study aimed to characterize the mechanical properties of aged human anterior mitral leaflets (AML) and posterior mitral leaflets (PML). The AML and PML samples from explanted human hearts (n = 21, mean age of 82.62 ± 8.77-years-old) were subjected to planar biaxial mechanical tests. The material stiffness, extensibility, and degree of anisotropy of the leaflet samples were quantified. The microstructure of the samples was assessed through histology. Both the AML and PML samples exhibited a nonlinear and anisotropic behavior with the circumferential direction being stiffer than the radial direction. The AML samples were significantly stiffer than the PML samples in both directions, suggesting that they should be modeled with separate sets of material properties in computational studies. Histological analysis indicated the changes in the tissue elastic constituents, including the fragmented and disorganized elastin network, the presence of fibrosis and proteoglycan/glycosaminoglycan infiltration and calcification, suggesting possible valvular degenerative characteristics in the aged human leaflet samples. Overall, stiffness increased and areal strain decreased with calcification severity. In addition, leaflet tissues from hypertensive individuals also exhibited a higher stiffness and low areal strain than normotensive individuals. There are significant differences in the mechanical properties of the two human mitral valve leaflets from this advanced age group. The morphologic changes in the tissue composition and structure also infer the structural and functional difference between aged human valves and those of animals.
Collapse
Affiliation(s)
- Thuy Pham
- Tissue Mechanics Laboratory, Department of Mechanical Engineering, Biomedical Engineering Program, University of Connecticut, Storrs, Connecticut, 06269
| | | |
Collapse
|
12
|
Rabbah JPM, Saikrishnan N, Siefert AW, Santhanakrishnan A, Yoganathan AP. Mechanics of healthy and functionally diseased mitral valves: a critical review. J Biomech Eng 2013; 135:021007. [PMID: 23445052 DOI: 10.1115/1.4023238] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The mitral valve is a complex apparatus with multiple constituents that work cohesively to ensure unidirectional flow between the left atrium and ventricle. Disruption to any or all of the components-the annulus, leaflets, chordae, and papillary muscles-can lead to backflow of blood, or regurgitation, into the left atrium, which deleteriously effects patient health. Through the years, a myriad of surgical repairs have been proposed; however, a careful appreciation for the underlying structural mechanics can help optimize long-term repair durability and inform medical device design. In this review, we aim to present the experimental methods and significant results that have shaped the current understanding of mitral valve mechanics. Data will be presented for all components of the mitral valve apparatus in control, pathological, and repaired conditions from human, animal, and in vitro studies. Finally, current strategies of patient specific and noninvasive surgical planning will be critically outlined.
Collapse
Affiliation(s)
- Jean-Pierre M Rabbah
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
| | | | | | | | | |
Collapse
|
13
|
Mansi T, Voigt I, Georgescu B, Zheng X, Mengue EA, Hackl M, Ionasec RI, Noack T, Seeburger J, Comaniciu D. An integrated framework for finite-element modeling of mitral valve biomechanics from medical images: application to MitralClip intervention planning. Med Image Anal 2012; 16:1330-46. [PMID: 22766456 DOI: 10.1016/j.media.2012.05.009] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2012] [Revised: 04/21/2012] [Accepted: 05/18/2012] [Indexed: 11/17/2022]
Abstract
Treatment of mitral valve (MV) diseases requires comprehensive clinical evaluation and therapy personalization to optimize outcomes. Finite-element models (FEMs) of MV physiology have been proposed to study the biomechanical impact of MV repair, but their translation into the clinics remains challenging. As a step towards this goal, we present an integrated framework for finite-element modeling of the MV closure based on patient-specific anatomies and boundary conditions. Starting from temporal medical images, we estimate a comprehensive model of the MV apparatus dynamics, including papillary tips, using a machine-learning approach. A detailed model of the open MV at end-diastole is then computed, which is finally closed according to a FEM of MV biomechanics. The motion of the mitral annulus and papillary tips are constrained from the image data for increased accuracy. A sensitivity analysis of our system shows that chordae rest length and boundary conditions have a significant influence upon the simulation results. We quantitatively test the generalization of our framework on 25 consecutive patients. Comparisons between the simulated closed valve and ground truth show encouraging results (average point-to-mesh distance: 1.49 ± 0.62 mm) but also the need for personalization of tissue properties, as illustrated in three patients. Finally, the predictive power of our model is tested on one patient who underwent MitralClip by comparing the simulated intervention with the real outcome in terms of MV closure, yielding promising prediction. By providing an integrated way to perform MV simulation, our framework may constitute a surrogate tool for model validation and therapy planning.
Collapse
Affiliation(s)
- Tommaso Mansi
- Siemens Corporation, Corporate Research and Technology, Image Analytics and Informatics, Princeton, NJ, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Lau K, Díaz-Zuccarini V, Scambler P, Burriesci G. Fluid–structure interaction study of the edge-to-edge repair technique on the mitral valve. J Biomech 2011; 44:2409-17. [DOI: 10.1016/j.jbiomech.2011.06.030] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2011] [Revised: 06/02/2011] [Accepted: 06/26/2010] [Indexed: 10/17/2022]
|
15
|
Stevanella M, Krishnamurthy G, Votta E, Swanson JC, Redaelli A, Ingels NB. Mitral leaflet modeling: Importance of in vivo shape and material properties. J Biomech 2011; 44:2229-35. [DOI: 10.1016/j.jbiomech.2011.06.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2011] [Revised: 05/02/2011] [Accepted: 06/03/2011] [Indexed: 10/18/2022]
|
16
|
Avanzini A, Donzella G, Libretti L. Functional and structural effects of percutaneous edge-to-edge double-orifice repair under cardiac cycle in comparison with suture repair. Proc Inst Mech Eng H 2011; 225:959-71. [DOI: 10.1177/0954411911414803] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Percutaneous procedures for double-orifice mitral valve repair using the MitraClip® device (clip) have been recently introduced as new treatment options as alternatives to medical management and open-heart surgery, especially for patients with high estimated operative risk. Similarly to the open-heart surgical technique, where suturing is used, the clip creates a double-orifice configuration that not only improves the closing function of the valve, but also significantly modifies its behaviour, particularly in the diastolic phase. While several clinical trials have been conducted, and are ongoing, in order to assess the safety and effectiveness of this technique, a deeper knowledge of the structural and functional effects on the valve, and of the cyclic loads transmitted to the clip itself, would allow a comparison with other repair techniques, and could serve as a foundation for possible further optimization of the clip design. The effects of the MitraClip® device developed by Evalve Inc. were studied by means of a finite element model of the mitral valve, specifically developed to study the structural effects of the original, suture-based, edge-to-edge technique. A second model was developed in order to simulate the effects of a suture with similar extension from the leaflet edge in a direction to the annulus, in order to compare the two repair techniques. The mitral valve area and transvalvular pressure gradient predicted by the models for the clip and the suture are quite similar. Similar leaflet cyclic stresses, both in value and in location, were noted for the two mechanisms of linking the leaflets, while minor differences were found in the load transmitted to the suture and the clip, with slightly higher values for the clip. The model satisfactorily allowed functional parameters (valve area and transvalvular pressure gradient) and structural parameters (load, leaflet stress) to be determined. Overall, the structural effects of the clip and the suture are quite similar under the cyclic loading conditions imposed by the cardiac cycle.
Collapse
Affiliation(s)
- A Avanzini
- Department of Mechanical and Industrial Engineering, University of Brescia, Italy
| | - G Donzella
- Department of Mechanical and Industrial Engineering, University of Brescia, Italy
| | - L Libretti
- Department of Mechanical and Industrial Engineering, University of Brescia, Italy
| |
Collapse
|
17
|
Stevanella M, Maffessanti F, Conti CA, Votta E, Arnoldi A, Lombardi M, Parodi O, Caiani EG, Redaelli A. Mitral Valve Patient-Specific Finite Element Modeling from Cardiac MRI: Application to an Annuloplasty Procedure. Cardiovasc Eng Technol 2011. [DOI: 10.1007/s13239-010-0032-4] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
18
|
Mohammadi H, Mequanint K. Prosthetic aortic heart valves: modeling and design. Med Eng Phys 2010; 33:131-47. [PMID: 20971672 DOI: 10.1016/j.medengphy.2010.09.017] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2010] [Revised: 07/19/2010] [Accepted: 09/24/2010] [Indexed: 10/18/2022]
Abstract
Although heart valve replacement is among the most common cardiovascular surgical procedures, their outcome is often difficult to predict. One of the reasons is the design and choice of the materials used for the fabrication of the prostheses. This review paper describes the use of modeling techniques in prosthetic heart valve (HV) design and aims at the justification and development of a polymer based trileaflet mechanical heart valve (MHV). The closing/opening phase behavior of the bileaflet MHV was investigated. The potential problem of valve failure due to crack propagation in the brittle pyrolytic carbon leaflet was also discussed. These studies suggest that although bileaflet MHV performs satisfactorily, there are justifications for improvement. Since the native aortic HV is trileaflet and made of anisotropic and hyperelastic tissue, one possible approach to a better MHV design is based on our ability to closely mimic the natural geometry and biomaterial properties.
Collapse
Affiliation(s)
- Hadi Mohammadi
- The Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.
| | | |
Collapse
|
19
|
Xu C, Brinster CJ, Jassar AS, Vergnat M, Eperjesi TJ, Gorman RC, Gorman JH, Jackson BM. A novel approach to in vivo mitral valve stress analysis. Am J Physiol Heart Circ Physiol 2010; 299:H1790-4. [PMID: 20952665 DOI: 10.1152/ajpheart.00370.2010] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Three-dimensional (3-D) echocardiography allows the generation of anatomically correct and time-resolved geometric mitral valve (MV) models. However, as imaged in vivo, the MV assumes its systolic geometric configuration only when loaded. Customarily, finite element analysis (FEA) is used to predict material stress and strain fields rendered by applying a load on an initially unloaded model. Therefore, this study endeavors to provide a framework for the application of in vivo MV geometry and FEA to MV physiology, pathophysiology, and surgical repair. We hypothesize that in vivo MV geometry can be reasonably used as a surrogate for the unloaded valve in computational (FEA) simulations, yielding reasonable and meaningful stress and strain magnitudes and distributions. Three experiments were undertaken to demonstrate that the MV leaflets are relatively nondeformed during systolic loading: 1) leaflet strain in vivo was measured using sonomicrometry in an ovine model, 2) hybrid models of normal human MVs as constructed using transesophageal real-time 3-D echocardiography (rt-3DE) were repeatedly loaded using FEA, and 3) serial rt-3DE images of normal human MVs were used to construct models at end diastole and end isovolumic contraction to detect any deformation during isovolumic contraction. The average linear strain associated with isovolumic contraction was 0.02 ± 0.01, measured in vivo with sonomicrometry. Repeated loading of the hybrid normal human MV demonstrated little change in stress or geometry: peak von Mises stress changed by <4% at all locations on the anterior and posterior leaflets. Finally, the in vivo human MV deformed minimally during isovolumic contraction, as measured by the mean absolute difference calculated over the surfaces of both leaflets between serial MV models: 0.53 ± 0.19 mm. FEA modeling of MV models derived from in vivo high-resolution truly 3-D imaging is reasonable and useful for stress prediction in MV pathologies and repairs.
Collapse
Affiliation(s)
- Chun Xu
- Gorman Cardiovascular Research Group, Glenolden, Pennsylvania, USA
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Hu Y, Shi L, Parameswaran S, Smirnov S, He Z. Left Ventricular Vortex Under Mitral Valve Edge-to-Edge Repair. Cardiovasc Eng Technol 2010; 1:235-243. [PMID: 21666755 DOI: 10.1007/s13239-010-0022-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Mitral valve (MV) edge-to-edge repair (ETER) changes MV geometry by approximation of MV leaflets, and impacts left ventricle (LV) filling fluid mechanics. The purpose of this study was to investigate LV vortex with MV ETER during diastole. A computational MV-LV model was developed with MV ETER at the central free edges of the anterior and posterior leaflets. It was supposed that LV would elongate apically during diastole. The elongation deformation was controlled by the intraventricular flow rate. MV leaflets were modeled as a semi-prolate sphere with two symmetrical circular orifices and fixed at the maximum valve opening. MV chordae were neglected. FLUENT was used to simulate blood flow through the MV and in the LV. MV ETER generated two jets deflected laterally toward the LV wall in rapid LV filling. The jets impinged the LV wall obliquely and moved apically along the LV wall. Jet energy was primarily lost near the impingement. The jet from each MV orifice was surrounded by a vortex ring. The two vortex rings dissipated at the end of diastole. The total energy loss increased inversely with the MV orifice area. The atrio-ventricular pressure gradient was adverse near the end of diastole and possibly in diastasis. Reduction of the total orifice area led to more increment in the transmitral pressure drop than in the transmitral velocity. In conclusion, during diastole, two deflected jets from the MV under ETER impinged the LV wall. Major energy loss occurred around the jet impingement. Two vortex rings dissipated at the end of diastole with little storage of inflow energy for blood ejection in the following process of systole. MV ETER increased energy loss and lowered LV filling efficiency. The maintaining of a larger orifice area after ETER might not significantly increase energy loss in the LV during diastole and the transmitral pressure drop. The adverse pressure gradient from the atrium to the LV might be the mechanism of MV closure in the late diastole.
Collapse
Affiliation(s)
- Yingying Hu
- Department of Mechanical Engineering, Texas Tech University, 7th St. and Boston Ave., PO Box 41021, Lubbock 79409-1021, TX, USA
| | | | | | | | | |
Collapse
|
21
|
Abstract
Computational simulations are playing an increasingly important role in enhancing our understanding of the normal human physiological function, etiology of diseased states, surgical and interventional planning, and in the design and evaluation of artificial implants. Researchers are taking advantage of computational simulations to speed up the initial design of implantable devices before a prototype is developed and hence able to reduce animal experimentation for the functional evaluation of the devices under development. A review of the reported studies to date relevant to the simulation of the native and prosthetic heart valve dynamics is the subject of the present paper. Potential future directions toward multi-scale simulation studies for our further understanding of the physiology and pathophysiology of heart valve dynamics and valvular implants are also discussed.
Collapse
|
22
|
He Z, Gao B, Bhattacharya S, Harrist T, Mathew S, Sun W. In Vitro Stretches of the Mitral Valve Anterior Leaflet Under Edge-to-Edge Repair Condition. J Biomech Eng 2009; 131:111012. [DOI: 10.1115/1.4000111] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Mitral valve edge-to-edge repair (ETER) alters valve mechanics, which may impact efficacy and durability of the repair. The objective of this paper was to quantify stretches in the central region of the anterior leaflet of the mitral valve after ETER with a single suture and 6 mm suture. Sixteen markers, forming a 4×4 array, were attached onto the central region of the mitral valve anterior leaflet. The mitral valve was subjected to ETER with a single suture and 6 mm suture, and mounted in an in vitro flow loop simulating physiological conditions. Images of the marker array were used to calculate marker displacement and stretch. A total of 9 mitral valves were tested. Two peak stretches were observed during a cardiac cycle, one in systole and the other in diastole under mitral valve edge-to-edge repair condition. The major principal (radial) stretch during systole was significantly greater than that during diastole. However, there was no significant difference between the minor principal (circumferential) stretch during diastole and that during systole. In addition, there were no significant differences in the radial and circumferential, or areal stretches and stretch rates during diastole between the single suture and 6 mm suture. The ETER subjects the mitral valve leaflets to double frequency of loading and unloading. Minor change in suture length may not result in a significant load difference in the central region of the anterior leaflet during diastole.
Collapse
Affiliation(s)
- Zhaoming He
- Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409-1021
| | - Bo Gao
- Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409-1021
| | - Shamik Bhattacharya
- Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409-1021
| | - Tyler Harrist
- Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409-1021
| | - Sibi Mathew
- Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409-1021
| | - Wei Sun
- Department of Mechanical Engineering, and Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269-3139
| |
Collapse
|