1
|
Valente R, Mourato A, Xavier J, Sousa P, Domingues T, Tavares P, Avril S, Tomás A, Fragata J. Experimental Protocols to Test Aortic Soft Tissues: A Systematic Review. Bioengineering (Basel) 2024; 11:745. [PMID: 39199703 PMCID: PMC11351783 DOI: 10.3390/bioengineering11080745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Accepted: 07/18/2024] [Indexed: 09/01/2024] Open
Abstract
Experimental protocols are fundamental for quantifying the mechanical behaviour of soft tissue. These data are crucial for advancing the understanding of soft tissue mechanics, developing and calibrating constitutive models, and informing the development of more accurate and predictive computational simulations and artificial intelligence tools. This paper offers a comprehensive review of experimental tests conducted on soft aortic tissues, employing the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) methodology, based on the Scopus, Web of Science, IEEE, Google Scholar and PubMed databases. This study includes a detailed overview of the test method protocols, providing insights into practical methodologies, specimen preparation and full-field measurements. The review also briefly discusses the post-processing methods applied to extract material parameters from experimental data. In particular, the results are analysed and discussed providing representative domains of stress-strain curves for both uniaxial and biaxial tests on human aortic tissue.
Collapse
Affiliation(s)
- Rodrigo Valente
- UNIDEMI, Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal; (R.V.); (A.M.)
| | - André Mourato
- UNIDEMI, Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal; (R.V.); (A.M.)
| | - José Xavier
- UNIDEMI, Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal; (R.V.); (A.M.)
- Intelligent Systems Associate Laboratory, LASI, 4800-058 Guimarães, Portugal
| | - Pedro Sousa
- INEGI, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (P.S.); (P.T.)
| | - Tiago Domingues
- INEGI, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (P.S.); (P.T.)
| | - Paulo Tavares
- INEGI, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (P.S.); (P.T.)
| | - Stéphane Avril
- Mines Saint-Etienne, University of Lyon, Inserm, Sainbiose U1059, Campus Santé Innovation, 10, rue de la Marandière, 42270 Saint-Priest-en-Jarez, France;
| | - António Tomás
- Department of Cardiothoracic Surgery, Santa Marta Hospital, Rua de Santa Marta, 1169-024 Lisboa, Portugal; (A.T.); (J.F.)
| | - José Fragata
- Department of Cardiothoracic Surgery, Santa Marta Hospital, Rua de Santa Marta, 1169-024 Lisboa, Portugal; (A.T.); (J.F.)
- Department of Surgery and Human Morphology, NOVA Medical School, Universidade NOVA de Lisboa, Campo Mártires da Pátria, 1169-056 Lisboa, Portugal
| |
Collapse
|
2
|
Ayyalasomayajula V, Pierrat B, Badel P. Evaluation of a multi-scale discrete fiber model for analyzing arterial failure. J Biomech 2023; 157:111700. [PMID: 37478803 DOI: 10.1016/j.jbiomech.2023.111700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 04/18/2023] [Accepted: 06/22/2023] [Indexed: 07/23/2023]
Abstract
So far, the prevalent rupture risk quantification of aortic aneurysms does not consider information of the underlying microscopic mechanisms. Uniaxial tension tests were performed on imaged aorta samples oriented in circumferential and longitudinal directions. To account for local heterogeneity in collagen fiber architecture, SHG imaging was performed on tissues at several locations prior to mechanical testing. This enabled the quantification of micro-scale information including organization of collagen fibers using relevant probability density functions. Two different modeling approaches are presented in this study for the sake of comparison. A multi-scale mechanical model was developed using this micro-structural information with collagen fibers as main components. accounting for non-affine fiber kinematics. Simultaneously, an embedded element model that accounts for affine fiber kinematics was developed in Abaqus using the same micro-structural information. Numerical simulations emulating uniaxial tension experiments were performed on the developed models. Global mechanical response of both models agreed well with the experimental data, although leading to mismatched material properties. The models present a rudimentary yet better than before representation of structure based description of aortic-tissue failure mechanics. reinforcing the importance of structural organization of micro-scale constituents and their kinematics in determining tissue failure.
Collapse
Affiliation(s)
- Venkat Ayyalasomayajula
- Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim, 7052, Norway.
| | - Baptiste Pierrat
- Mines Saint-Étienne, CIS-EMSE, F-42023 Saint-Étienne, France; INSERM, U1059, SAINBIOSE, F-42023 Saint-Étienne, France; Université de Lyon, F-69000 Lyon, France
| | - Pierre Badel
- Mines Saint-Étienne, CIS-EMSE, F-42023 Saint-Étienne, France; INSERM, U1059, SAINBIOSE, F-42023 Saint-Étienne, France; Université de Lyon, F-69000 Lyon, France
| |
Collapse
|
3
|
Microstructure and mechanics of the bovine trachea: Layer specific investigations through SHG imaging and biaxial testing. J Mech Behav Biomed Mater 2022; 134:105371. [PMID: 35868065 DOI: 10.1016/j.jmbbm.2022.105371] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 06/20/2022] [Accepted: 07/09/2022] [Indexed: 11/22/2022]
Abstract
The trachea is a complex tissue made up of hyaline cartilage, fibrous tissue, and muscle fibers. Currently, the knowledge of microscopic structural organization of these components and their role in determining the tissue's mechanical response is very limited. The purpose of this study is to provide data on the microstructure of the tracheal components and its influence on tissue's mechanical response. Five bovine tracheae were used in this study. Adventitia, cartilage, mucosa/submucosa, and trachealis muscle layers were methodically cut out from the whole tissue. Second-harmonic generation(SHG) via multi-photon microscopy (MPM) enabled imaging of collagen fibers and muscle fibers. Simultaneously, a planar biaxial test rig was used to record the mechanical behavior of each layer. In total 60 samples were tested and analyzed. Fiber architecture in the adventitia and mucosa/submucosa layer showed high degree of anisotropy with the mean fiber angle varying from sample to sample. The trachealis muscle displayed neat layers of fibers organized in the longitudinal direction. The cartilage also displayed a structure of thick mesh-work of collagen type II organized predominantly towards the circumferential direction. Further, mechanical testing demonstrated the anisotropic nature of the tissue components. The cartilage was identified as the stiffest component for strain level < 20% and hence the primary load bearing component. The other three layers displayed a non-linear mechanical response which could be explained by the structure and organization of their fibers. This study is useful in enhancing the utilization of structurally motivated material models for predicting tracheal overall mechanical response.
Collapse
|
4
|
Furdella KJ, Higuchi S, Kim K, Doetschman T, Wagner WR, Vande Geest JP. ACUTE ELUTION OF TGFβ2 AFFECTS THE SMOOTH MUSCLE CELLS IN A COMPLIANCE-MATCHED VASCULAR GRAFT. Tissue Eng Part A 2022; 28:640-650. [PMID: 35521649 DOI: 10.1089/ten.tea.2021.0161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Transforming growth factor beta 2 (TGFβ2) is a pleiotropic growth factor that plays a vital role in smooth muscle cell (SMC) function. Our prior in vitro work has shown that SMC response can be modulated with TGFβ2 stimulation in a dose dependent manner. In particular, we have shown that increasing concentrations of TGFβ2 shift SMCs from a migratory to a synthetic behavior. In this work, electrospun compliance-matched and hypocompliant TGFβ2-eluting TEVGs were implanted into Sprague Dawley rats for 5 days to observe SMC population and collagen production. TEVGs were fabricated using a combined computational and experimental approach that varied the ratio of gelatin:polycaprolactone to be either compliance-matched or twice as stiff as rat aorta (hypocompliant). TGFβ2 concentrations of 0, 10, 100 ng/mg were added to both graft types (n=3 in each group) and imaged in vivo using ultrasound. Histological markers (SMC, macrophage, collagen, and elastin) were evaluated following explantation at 5 days. In vivo ultrasound showed that compliance-matched TEVGs became stiffer as TGFβ2 increased (100 ng/mg TEVGS compared to rat aorta, p<0.01) while all hypocompliant grafts remained stiffer than control rat aorta. In vivo velocity and diameter were also not significantly different than control vessels. The compliance-matched 10 ng/mg group had an elevated SMC signal (myosin heavy chain) compared to the 0 and 100 ng/mg grafts (p=0.0009 & 0.0006 ). Compliance-matched TEVGs containing 100 ng/mg TGFβ2 had an increase in collagen production (p<0.01), general immune response (p<0.05), and a decrease in SMC population to the 0 and 10 ng/mg groups. All hypocompliant groups were found to be similar, suggesting a lower rate of TGFβ2 release in these TEVGs. Our results suggest that TGFβ2 can modulate in vivo SMC phenotype over an acute implantation period, which is consistent with our prior in vitro work. To the author's knowledge, this is first in vivo rat study that evaluates a TGFβ2-eluting TEVG.
Collapse
Affiliation(s)
- Kenneth John Furdella
- University of Pittsburgh Swanson School of Engineering, 110071, Bioengineering, Pittsburgh, Pennsylvania, United States;
| | - Shinichi Higuchi
- University of Pittsburgh Swanson School of Engineering, 110071, McGowan Institute for Regenerative Medicine, Pittsburgh, Pennsylvania, United States;
| | - Kang Kim
- University of Pittsburgh Swanson School of Engineering, 110071, Department of Bioengineering, Pittsburgh, Pennsylvania, United States;
| | - Tom Doetschman
- University of Arizona Biochemistry and Molecular and Cellular Biology program, 242717, Tucson, Arizona, United States;
| | - William R Wagner
- University of Pittsburgh, 6614, McGowan Institute for Regenerative Medicine, Pittsburgh, Pennsylvania, United States;
| | - Jonathan P Vande Geest
- University of Pittsburgh Swanson School of Engineering, 110071, Bioengineering, Pittsburgh, Pennsylvania, United States;
| |
Collapse
|
5
|
Pathare SJ, Eng W, Lee SJJ, Ramasubramanian AK. Fibrin prestress due to platelet aggregation and contraction increases clot stiffness. BIOPHYSICAL REPORTS 2021; 1:100022. [PMID: 36425457 PMCID: PMC9680775 DOI: 10.1016/j.bpr.2021.100022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Accepted: 09/08/2021] [Indexed: 06/16/2023]
Abstract
Efficient hemorrhagic control is attained through the formation of strong and stable blood clots at the site of injury. Although it is known that platelet-driven contraction can dramatically influence clot stiffness, the underlying mechanisms by which platelets assist fibrin in resisting external loads are not understood. In this study, we delineate the contribution of platelet-fibrin interactions to clot tensile mechanics using a combination of new mechanical measurements, image analysis, and structural mechanics simulation. Based on uniaxial tensile test data using custom-made microtensometer and fluorescence microscopy of platelet aggregation and platelet-fibrin interactions, we show that integrin-mediated platelet aggregation and actomyosin-driven platelet contraction synergistically increase the elastic modulus of the clots. We demonstrate that the mechanical and geometric response of an active contraction model of platelet aggregates compacting vicinal fibrin is consistent with the experimental data. The model suggests that platelet contraction induces prestress in fibrin fibers and increases the effective stiffness in both cross-linked and noncross-linked clots. Our results provide evidence for fibrin compaction at discrete nodes as a major determinant of mechanical response to applied loads.
Collapse
Affiliation(s)
| | - Wilson Eng
- Department of Mechanical Engineering, San José State University, San José, California
| | - Sang-Joon J. Lee
- Department of Mechanical Engineering, San José State University, San José, California
| | | |
Collapse
|
6
|
Rego BV, Weiss D, Bersi MR, Humphrey JD. Uncertainty quantification in subject-specific estimation of local vessel mechanical properties. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3535. [PMID: 34605615 PMCID: PMC9019846 DOI: 10.1002/cnm.3535] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Accepted: 09/26/2021] [Indexed: 05/08/2023]
Abstract
Quantitative estimation of local mechanical properties remains critically important in the ongoing effort to elucidate how blood vessels establish, maintain, or lose mechanical homeostasis. Recent advances based on panoramic digital image correlation (pDIC) have made high-fidelity 3D reconstructions of small-animal (e.g., murine) vessels possible when imaged in a variety of quasi-statically loaded configurations. While we have previously developed and validated inverse modeling approaches to translate pDIC-measured surface deformations into biomechanical metrics of interest, our workflow did not heretofore include a methodology to quantify uncertainties associated with local point estimates of mechanical properties. This limitation has compromised our ability to infer biomechanical properties on a subject-specific basis, such as whether stiffness differs significantly between multiple material locations on the same vessel or whether stiffness differs significantly between multiple vessels at a corresponding material location. In the present study, we have integrated a novel uncertainty quantification and propagation pipeline within our inverse modeling approach, relying on empirical and analytic Bayesian techniques. To demonstrate the approach, we present illustrative results for the ascending thoracic aorta from three mouse models, quantifying uncertainties in constitutive model parameters as well as circumferential and axial tangent stiffness. Our extended workflow not only allows parameter uncertainties to be systematically reported, but also facilitates both subject-specific and group-level statistical analyses of the mechanics of the vessel wall.
Collapse
Affiliation(s)
- Bruno V. Rego
- Department of Biomedical Engineering, School of Engineering & Applied Science, Yale University, New Haven, CT, USA
| | - Dar Weiss
- Department of Biomedical Engineering, School of Engineering & Applied Science, Yale University, New Haven, CT, USA
| | - Matthew R. Bersi
- Department of Mechanical Engineering & Materials Science, McKelvey School of Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Jay D. Humphrey
- Department of Biomedical Engineering, School of Engineering & Applied Science, Yale University, New Haven, CT, USA
- Correspondence Jay D. Humphrey, Department of Biomedical Engineering, Malone Engineering Center, Yale University, New Haven, CT, USA.
| |
Collapse
|
7
|
Furdella KJ, Higuchi S, Behrangzade A, Kim K, Wagner WR, Vande Geest JP. In-vivo assessment of a tissue engineered vascular graft computationally optimized for target vessel compliance. Acta Biomater 2021; 123:298-311. [PMID: 33482362 DOI: 10.1016/j.actbio.2020.12.058] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 12/22/2020] [Accepted: 12/29/2020] [Indexed: 11/24/2022]
Abstract
Tissue engineered vascular grafts (TEVGs) have the ability to be tuned to match a target vessel's compliance, diameter, wall thickness, and thereby prevent compliance mismatch. In this work, TEVG compliance was manipulated by computationally tuning its layered composition or by manipulating a crosslinking agent (genipin). In particular, these three acelluluar TEVGs were compared: a compliance matched graft (CMgel - high gelatin content); a hypocompliant PCL graft (HYPOpcl - high polycaprolactone content); and a hypocompliant genipin graft (HYPOgen - equivalent composition as CMgel but hypocompliant via increased genipin crosslinking). All constructs were implanted interpositionally into the abdominal aorta of 21 Sprague Dawley rats (n=7, males=11, females=10) for 28 days, imaged in-vivo using ultrasound, explanted, and assessed for remodeling using immunofluorescence and two photon excitation fluorescence imaging. Compliance matched grafts remained compliance-matched in-vivo compared to the hypocompliant grafts through 4 weeks (p<0.05). Construct degradation and cellular infiltration was increased in the CMgel and HYPOgen TEVGs. Contractile smooth muscle cell markers in the proximal anastomosis of the graft were increased in the CMgel group compared to the HYPOpcl (p=0.007) and HYPOgen grafts (p=0.04). Both hypocompliant grafts also had an increased pro-inflammatory response (increased ratio of CD163 to CD86 in the mid-axial location) compared to the CMgel group. Our results suggest that compliance matching using a computational optimization approach leads to the improved acute (28 day) remodeling of TEVGs. To the authors' knowledge, this is the first in-vivo rat study investigating TEVGs that have been computationally optimized for target vessel compliance.
Collapse
|
8
|
Butlin M, Tan I, Spronck B, Avolio AP. Measuring Arterial Stiffness in Animal Experimental Studies. Arterioscler Thromb Vasc Biol 2020; 40:1068-1077. [PMID: 32268787 PMCID: PMC7176337 DOI: 10.1161/atvbaha.119.313861] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The arterial wall is a composite material of elastin, collagen, and extracellular matrix with acutely modifiable material properties through the action of smooth muscle cells. Therefore, arterial stiffness is a complex parameter that changes not only with long-term remodeling of the wall constituents but also with acute contraction or relaxation of smooth muscle or with changes in the acute distending pressure to which the artery is exposed. It is not possible to test all these aspects using noninvasive or even invasive techniques in humans. Full characterization of the mechanical properties of the artery and the specific arterial factors causing changes to stiffness with disease or modified lifestyle currently require animal studies. This article summarizes the major in vivo and ex vivo techniques to measure the different aspects of arterial stiffness in animal studies.
Collapse
Affiliation(s)
- Mark Butlin
- From the Department of Biomedical Sciences, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW, Australia (M.B., I.T., A.P.A.)
| | - Isabella Tan
- From the Department of Biomedical Sciences, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW, Australia (M.B., I.T., A.P.A.)
| | - Bart Spronck
- Department of Biomedical Engineering, School of Engineering & Applied Science, Yale University, New Haven, CT (B.S.).,Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, the Netherlands (B.S.)
| | - Alberto P Avolio
- From the Department of Biomedical Sciences, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW, Australia (M.B., I.T., A.P.A.)
| |
Collapse
|
9
|
Cavinato C, Badel P, Krasny W, Avril S, Morin C. Experimental Characterization of Adventitial Collagen Fiber Kinematics Using Second-Harmonic Generation Imaging Microscopy: Similarities and Differences Across Arteries, Species and Testing Conditions. MULTI-SCALE EXTRACELLULAR MATRIX MECHANICS AND MECHANOBIOLOGY 2020. [DOI: 10.1007/978-3-030-20182-1_5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
10
|
van Haaften EE, van Turnhout MC, Kurniawan NA. Image-based analysis of uniaxial ring test for mechanical characterization of soft materials and biological tissues. SOFT MATTER 2019; 15:3353-3361. [PMID: 30924833 DOI: 10.1039/c8sm02343c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Uniaxial ring test is a widely used mechanical characterization method for a variety of materials, from industrial elastomers to biological materials. Here we show that the combination of local material compression, bending, and stretching during uniaxial ring test results in a geometry-dependent deformation profile that can introduce systematic errors in the extraction of mechanical parameters. We identify the stress and strain regimes under which stretching dominates and develop a simple image-based analysis approach that eliminates these systematic errors. We rigorously test this approach computationally and experimentally, and demonstrate that we can accurately estimate the sample mechanical properties for a wide range of ring geometries. As a proof of concept for its application, we use the approach to analyze explanted rat vascular tissues and find a clear temporal change in the mechanical properties of these explants after graft implantation. The image-based approach can therefore offer a straightforward, versatile, and accurate method for mechanically characterizing new classes of soft and biological materials.
Collapse
Affiliation(s)
- Eline E van Haaften
- Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands and Institute for Complex Molecular Systems, Eindhoven University of Technology, The Netherlands
| | - Mark C van Turnhout
- Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands
| | - Nicholas A Kurniawan
- Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands and Institute for Complex Molecular Systems, Eindhoven University of Technology, The Netherlands
| |
Collapse
|
11
|
Tamimi EA, Ardila DC, Ensley BD, Kellar RS, Vande Geest J. Computationally optimizing the compliance of multilayered biomimetic tissue engineered vascular grafts. J Biomech Eng 2019; 141:2725826. [PMID: 30778568 DOI: 10.1115/1.4042902] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2018] [Indexed: 12/19/2022]
Abstract
Coronary artery bypass grafts used to treat coronary artery disease often fail due to compliance mismatch. In this study, we have developed an experimental/computational approach to fabricate an acellular biomimetic hybrid tissue engineered vascular graft composed of alternating layers of electrospun porcine gelatin/polycaprolactone (PCL) and human tropoelastin/PCL blends with the goal of compliance-matching to rat abdominal aorta, while maintaining specific geometrical constraints. Polymeric blends at three different gelatin:PCL (G:PCL) and tropoelastin:PCL (T:PCL) ratios (80:20, 50:50 and 20:80) were mechanically characterized. The stress-strain data was used to develop predictive models, which were used as part of an optimization scheme that was implemented to determine the ratios of G:PCL and T:PCL and the thickness of the individual layers within a tissue engineered vascular graft that would compliance match a target compliance value. The hypocompliant, isocompliant, and hypercompliant grafts had target compliance values of 0.000256, 0.000568 and 0.000880 mmHg-1, respectively. Experimental validation of the optimization demonstrated that the hypercompliant and isocompliant grafts were not statistically significant from their respective target compliance values (p-value=0.37 and 0.89, respectively). The experimental compliance value of the hypocompliant graft was statistically significant than their target compliance value (p-value=0.047). We have successfully demonstrated a design optimization scheme that can be used to fabricate multilayered and biomimetic vascular grafts with targeted geometry and compliance.
Collapse
Affiliation(s)
- Ehab Akram Tamimi
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
| | - Diana Catalina Ardila
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
| | | | - Robert S Kellar
- Center for Bioengineering Innovation, Northern Arizona University, Flagstaff, AZ, 86011; Department of Mechanical Engineering, Northern Arizona University, Flagstaff, AZ, 86011; Department of Biological Sciences, Northern Arizona University, Flagstaff, AZ, 86011
| | - Jonathan Vande Geest
- ASME Member, Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States, McGowan Institute for Regenerative Medicine, 300 Technology Drive, Pittsburgh, PA, United State 15219
| |
Collapse
|
12
|
Yu X, Turcotte R, Seta F, Zhang Y. Micromechanics of elastic lamellae: unravelling the role of structural inhomogeneity in multi-scale arterial mechanics. J R Soc Interface 2018; 15:rsif.2018.0492. [PMID: 30333250 DOI: 10.1098/rsif.2018.0492] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Accepted: 09/20/2018] [Indexed: 01/15/2023] Open
Abstract
Microstructural deformation of elastic lamellae plays important roles in maintaining arterial tissue homeostasis and regulating vascular smooth muscle cell fate. Our study unravels the underlying microstructural origin that enables elastic lamellar layers to evenly distribute the stresses through the arterial wall caused by intraluminal distending pressure, a fundamental requirement for tissue and cellular function. A new experimental approach was developed to quantify the spatial organization and unfolding of elastic lamellar layers under pressurization in mouse carotid arteries by coupling physiological extension-inflation and multiphoton imaging. Tissue-level circumferential stretch was obtained from analysis of the deformation of a thick-walled cylinder. Our results show that the unfolding and extension of lamellar layers contribute simultaneously to tissue-level deformation. The inner lamellar layers are wavier and unfold more than the outer layers. This waviness gradient compensates the larger tissue circumferential stretch experienced at the inner surface, thus equalizing lamellar layer extension through the arterial wall. Discoveries from this study reveal the importance of structural inhomogeneity in maintaining tissue homeostasis through the arterial wall, and may have profound implications on vascular remodelling in aging and diseases, as well as in tissue engineering of functional blood vessels.
Collapse
Affiliation(s)
- Xunjie Yu
- Department of Mechanical Engineering, Boston University, Boston, MA, USA
| | | | - Francesca Seta
- Vascular Biology Section, Boston University School of Medicine, Boston, MA, USA
| | - Yanhang Zhang
- Department of Mechanical Engineering, Boston University, Boston, MA, USA .,Department of Biomedical Engineering, Boston University, Boston, MA, USA
| |
Collapse
|
13
|
Thoerner RP, King JD, Saunders MM. Application of Design Aspects in Uniaxial Loading Machine Development. J Vis Exp 2018. [PMID: 30295656 DOI: 10.3791/58168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
In terms of accurate and precise mechanical testing, machines run the continuum. Whereas commercial platforms offer excellent accuracy, they can be cost-prohibitive, often priced in the $100,000 - $200,000 price range. At the other extreme are stand-alone manual devices that often lack repeatability and accuracy (e.g., a manual crank device). However, if a single use is indicated, it is over-engineering to design and machine something overly elaborate. Nonetheless, there are occasions where machines are designed and built in-house to accomplish a motion not attainable with the existing machines in the laboratory. Described in detail here is one such device. It is a loading platform that enables pure uniaxial loading. Standard loading machines typically are biaxial in that linear loading occurs along the axis and rotary loading occurs about the axis. During testing with these machines, a load is applied to one end of the specimen while the other end remains fixed. These systems are not capable of conducting pure axial testing in which tension/compression is applied equally to the specimen ends. The platform developed in this paper enables the equal and opposite loading of specimens. While it can be used for compression, here the focus is on its use in pure tensile loading. The device incorporates commercial load cells and actuators (movers) and, as is the case with machines built in-house, a frame is machined to hold the commercial parts and fixtures for testing.
Collapse
|
14
|
Collagen fibre characterisation in arterial tissue under load using SALS. J Mech Behav Biomed Mater 2017; 75:359-368. [DOI: 10.1016/j.jmbbm.2017.07.036] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 07/13/2017] [Accepted: 07/25/2017] [Indexed: 01/06/2023]
|
15
|
Lynch B, Bancelin S, Bonod-Bidaud C, Gueusquin JB, Ruggiero F, Schanne-Klein MC, Allain JM. A novel microstructural interpretation for the biomechanics of mouse skin derived from multiscale characterization. Acta Biomater 2017; 50:302-311. [PMID: 28043893 DOI: 10.1016/j.actbio.2016.12.051] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 11/15/2016] [Accepted: 12/29/2016] [Indexed: 11/17/2022]
Abstract
Skin is a complex, multi-layered organ, with important functions in the protection of the body. The dermis provides structural support to the epidermal barrier, and thus has attracted a large number of mechanical studies. As the dermis is made of a mixture of stiff fibres embedded in a soft non-fibrillar matrix, it is classically considered that its mechanical response is based on an initial alignment of the fibres, followed by the stretching of the aligned fibres. Using a recently developed set-up combining multiphoton microscopy with mechanical assay, we imaged the fibres network evolution during dermis stretching. These observations, combined with a wide set of mechanical tests, allowed us to challenge the classical microstructural interpretation of the mechanical properties of the dermis: we observed a continuous alignment of the collagen fibres along the stretching. All our results can be explained if each fibre contributes by a given stress to the global response. This plastic response is likely due to inner sliding inside each fibre. The non-linear mechanical response is due to structural effects of the fibres network in interaction with the surrounding non-linear matrix. This multiscale interpretation explains our results on genetically-modified mice with a simple alteration of the dermis microstructure. STATEMENT OF SIGNIFICANCE Soft tissues, as skin, tendon or aorta, are made of extra-cellular matrix, with very few cells embedded inside. The matrix is a mixture of water and biomolecules, which include the collagen fibre network. The role of the collagen is fundamental since the network is supposed to control the tissue mechanical properties and remodeling: the cells attach to the collagen fibres and feel the network deformations. This paper challenges the classical link between fibres organization and mechanical properties. To do so, it uses multiscale observations combined to a large set of mechanical loading. It thus appears that the behaviour at low stretches is mostly controlled by the network structural response, while, at large stretches, the fibre inner-sliding dominate.
Collapse
Affiliation(s)
- Barbara Lynch
- LMS, Ecole Polytechnique, CNRS, Université Paris-Saclay, Palaiseau, France
| | - Stéphane Bancelin
- LOB, Ecole Polytechnique, CNRS, INSERM, Université Paris-Saclay, Palaiseau, France
| | - Christelle Bonod-Bidaud
- Institut de Génomique Fonctionnelle de Lyon, ENS-Lyon, CNRS, Université de Lyon, Lyon, France
| | | | - Florence Ruggiero
- Institut de Génomique Fonctionnelle de Lyon, ENS-Lyon, CNRS, Université de Lyon, Lyon, France
| | | | - Jean-Marc Allain
- LMS, Ecole Polytechnique, CNRS, Université Paris-Saclay, Palaiseau, France; Inria, Université Paris-Saclay, Palaiseau, France.
| |
Collapse
|
16
|
Golob MJ, Tabima DM, Wolf GD, Johnston JL, Forouzan O, Mulchrone AM, Kellihan HB, Bates ML, Chesler NC. Pulmonary arterial strain- and remodeling-induced stiffening are differentiated in a chronic model of pulmonary hypertension. J Biomech 2017; 55:92-98. [PMID: 28262286 DOI: 10.1016/j.jbiomech.2017.02.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Revised: 01/30/2017] [Accepted: 02/11/2017] [Indexed: 02/06/2023]
Abstract
Pulmonary hypertension (PH) is a debilitating vascular disease that leads to pulmonary artery (PA) stiffening, which is a predictor of patient mortality. During PH development, PA stiffening adversely affects right ventricular function. PA stiffening has been investigated through the arterial nonlinear elastic response during mechanical testing using a canine PH model. However, only circumferential properties were reported and in the absence of chronic PH-induced PA remodeling. Remodeling can alter arterial nonlinear elastic properties via chronic changes in extracellular matrix (ECM) content and geometry. Here, we used an established constitutive model to demonstrate and differentiate between strain-stiffening, which is due to nonlinear elasticity, and remodeling-induced stiffening, which is due to ECM and geometric changes, in a canine model of chronic thromboembolic PH (CTEPH). To do this, circumferential and axial tissue strips of large extralobar PAs from control and CTEPH tissues were tested in uniaxial tension, and data were fit to a phenomenological constitutive model. Strain-induced stiffening was evident from mechanical testing as nonlinear elasticity in both directions and computationally by a high correlation coefficient between the mechanical data and model (R2=0.89). Remodeling-induced stiffening was evident from a significant increase in the constitutive model stress parameter, which correlated with increased PA collagen content and decreased PA elastin content as measured histologically. The ability to differentiate between strain- and remodeling-induced stiffening in vivo may lead to tailored clinical treatments for PA stiffening in PH patients.
Collapse
Affiliation(s)
- Mark J Golob
- Department of Biomedical Engineering, University of Wisconsin-Madison College of Engineering, Madison, WI 53706, United States
| | - Diana M Tabima
- Department of Biomedical Engineering, University of Wisconsin-Madison College of Engineering, Madison, WI 53706, United States
| | - Gregory D Wolf
- Department of Biomedical Engineering, University of Wisconsin-Madison College of Engineering, Madison, WI 53706, United States
| | - James L Johnston
- Department of Biomedical Engineering, University of Wisconsin-Madison College of Engineering, Madison, WI 53706, United States
| | - Omid Forouzan
- Department of Biomedical Engineering, University of Wisconsin-Madison College of Engineering, Madison, WI 53706, United States
| | - Ashley M Mulchrone
- Department of Biomedical Engineering, University of Wisconsin-Madison College of Engineering, Madison, WI 53706, United States
| | - Heidi B Kellihan
- Department of Veterinary Medicine, University of Wisconsin-Madison, Madison, WI 53706, United States
| | - Melissa L Bates
- Department of Physiology, University of Iowa, Iowa City, IA 52242, United States
| | - Naomi C Chesler
- Department of Biomedical Engineering, University of Wisconsin-Madison College of Engineering, Madison, WI 53706, United States.
| |
Collapse
|
17
|
Harrison S, Tamimi E, Uhlorn J, Leach T, Vande Geest JP. Computationally Optimizing the Compliance of a Biopolymer Based Tissue Engineered Vascular Graft. J Biomech Eng 2016; 138:2473573. [PMID: 26593773 DOI: 10.1115/1.4032060] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2015] [Indexed: 11/08/2022]
Abstract
Coronary heart disease is a leading cause of death among Americans for which coronary artery bypass graft (CABG) surgery is a standard surgical treatment. The success of CABG surgery is impaired by a compliance mismatch between vascular grafts and native vessels. Tissue engineered vascular grafts (TEVGs) have the potential to be compliance matched and thereby reduce the risk of graft failure. Glutaraldehyde (GLUT) vapor-crosslinked gelatin/fibrinogen constructs were fabricated and mechanically tested in a previous study by our research group at 2, 8, and 24 hrs of GLUT vapor exposure. The current study details a computational method that was developed to predict the material properties of our constructs for crosslinking times between 2 and 24 hrs by interpolating the 2, 8, and 24 hrs crosslinking time data. matlab and abaqus were used to determine the optimal combination of fabrication parameters to produce a compliance matched construct. The validity of the method was tested by creating a 16-hr crosslinked construct of 130 μm thickness and comparing its compliance to that predicted by the optimization algorithm. The predicted compliance of the 16-hr construct was 0.00059 mm Hg-1 while the experimentally determined compliance was 0.00065 mm Hg-1, a relative difference of 9.2%. Prior data in our laboratory has shown the compliance of the left anterior descending porcine coronary (LADC) artery to be 0.00071 ± 0.0003 mm Hg-1. Our optimization algorithm predicts that a 258-μm-thick construct that is GLUT vapor crosslinked for 8.1 hrs would match LADC compliance. This result is consistent with our previous work demonstrating that an 8-hr GLUT vapor crosslinked construct produces a compliance that is not significantly different from a porcine coronary LADC.
Collapse
|
18
|
Tamimi E, Ardila DC, Haskett DG, Doetschman T, Slepian MJ, Kellar RS, Vande Geest JP. Biomechanical Comparison of Glutaraldehyde-Crosslinked Gelatin Fibrinogen Electrospun Scaffolds to Porcine Coronary Arteries. J Biomech Eng 2016; 138:2466198. [PMID: 26501189 DOI: 10.1115/1.4031847] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Indexed: 12/17/2022]
Abstract
Cardiovascular disease (CVD) is the leading cause of death for Americans. As coronary artery bypass graft surgery (CABG) remains a mainstay of therapy for CVD and native vein grafts are limited by issues of supply and lifespan, an effective readily available tissue-engineered vascular graft (TEVG) for use in CABG would provide drastic improvements in patient care. Biomechanical mismatch between vascular grafts and native vasculature has been shown to be the major cause of graft failure, and therefore, there is need for compliance-matched biocompatible TEVGs for clinical implantation. The current study investigates the biaxial mechanical characterization of acellular electrospun glutaraldehyde (GLUT) vapor-crosslinked gelatin/fibrinogen cylindrical constructs, using a custom-made microbiaxial optomechanical device (MOD). Constructs crosslinked for 2, 8, and 24 hrs are compared to mechanically characterized porcine left anterior descending coronary (LADC) artery. The mechanical response data were used for constitutive modeling using a modified Fung strain energy equation. The results showed that constructs crosslinked for 2 and 8 hrs exhibited circumferential and axial tangential moduli (ATM) similar to that of the LADC. Furthermore, the 8-hrs experimental group was the only one to compliance-match the LADC, with compliance values of 0.0006±0.00018 mm Hg-1 and 0.00071±0.00027 mm Hg-1, respectively. The results of this study show the feasibility of meeting mechanical specifications expected of native arteries through manipulating GLUT vapor crosslinking time. The comprehensive mechanical characterization of cylindrical biopolymer constructs in this study is an important first step to successfully develop a biopolymer compliance-matched TEVG.
Collapse
|
19
|
Haskett DG, Maestas D, Howerton SJ, Smith T, Ardila DC, Doetschman T, Utzinger U, McGrath D, McIntyre JO, Vande Geest JP. 2-Photon Characterization of Optical Proteolytic Beacons for Imaging Changes in Matrix-Metalloprotease Activity in a Mouse Model of Aneurysm. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2016; 22:349-360. [PMID: 26903264 PMCID: PMC4823162 DOI: 10.1017/s1431927616000088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Abdominal aortic aneurysm is a multifactorial disease that is a leading cause of death in developed countries. Matrix-metalloproteases (MMPs) are part of the disease process, however, assessing their role in disease initiation and progression has been difficult and animal models have become essential. Combining Förster resonance energy transfer (FRET) proteolytic beacons activated in the presence of MMPs with 2-photon microscopy allows for a novel method of evaluating MMP activity within the extracellular matrix (ECM). Single and 2-photon spectra for proteolytic beacons were determined in vitro. Ex vivo experiments using the apolipoprotein E knockout angiotensin II-infused mouse model of aneurysm imaged ECM architecture simultaneously with the MMP-activated FRET beacons. 2-photon spectra of the two-color proteolytic beacons showed peaks for the individual fluorophores that enable imaging of MMP activity through proteolytic cleavage. Ex vivo imaging of the beacons within the ECM revealed both microstructure and MMP activity. 2-photon imaging of the beacons in aneurysmal tissue showed an increase in proteolytic cleavage within the ECM (p<0.001), thus indicating an increase in MMP activity. Our data suggest that FRET-based proteolytic beacons show promise in assessing MMP activity within the ECM and will therefore allow future studies to identify the heterogeneous distribution of simultaneous ECM remodeling and protease activity in aneurysmal disease.
Collapse
Affiliation(s)
- Darren G. Haskett
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| | - David Maestas
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
- Department of Molecular and Cellular Biology, The University of Arizona, Tucson, AZ 85721, USA
| | - Stephen J. Howerton
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| | - Tyler Smith
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| | - D. Catalina Ardila
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| | - Tom Doetschman
- Department of Cellular and Molecular Medicine, The University of Arizona, Tucson, AZ 85721, USA
- BIO5 Institute, The University of Arizona, Tucson, AZ 85721, USA
| | - Urs Utzinger
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
- BIO5 Institute, The University of Arizona, Tucson, AZ 85721, USA
| | - Dominic McGrath
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
- Department of Chemistry and Biochemistry, The University of Arizona, Tucson, AZ 85721, USA
- BIO5 Institute, The University of Arizona, Tucson, AZ 85721, USA
| | - J. Oliver McIntyre
- Departments of Radiology and Radiological Sciences and Cancer Biology, Vanderbilt University, Nashville, TN 37232, USA
| | - Jonathan P. Vande Geest
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ 85721, USA
- BIO5 Institute, The University of Arizona, Tucson, AZ 85721, USA
- Department of Bioengineering, The University of Pittsburgh, Pittsburgh, PA 15219, USA
| |
Collapse
|
20
|
Kohn JC, Chen A, Cheng S, Kowal DR, King MR, Reinhart-King CA. Mechanical heterogeneities in the subendothelial matrix develop with age and decrease with exercise. J Biomech 2016; 49:1447-1453. [PMID: 27020750 DOI: 10.1016/j.jbiomech.2016.03.016] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2015] [Revised: 03/03/2016] [Accepted: 03/10/2016] [Indexed: 12/24/2022]
Abstract
Arterial stiffening occurs with age and is associated with lack of exercise. Notably both age and lack of exercise are major cardiovascular risk factors. While it is well established that bulk arterial stiffness increases with age, more recent data suggest that the intima, the innermost arterial layer, also stiffens during aging. Micro-scale mechanical characterization of individual layers is important because cells primarily sense the matrix that they are in contact with and not necessarily the bulk stiffness of the vessel wall. To investigate the relationship between age, exercise, and subendothelial matrix stiffening, atomic force microscopy was utilized here to indent the subendothelial matrix of the thoracic aorta from young, aged-sedentary, and aged-exercised mice, and elastic modulus values were compared to conventional pulse wave velocity measurements. The subendothelial matrix elastic modulus was elevated in aged-sedentary mice compared to young or aged-exercised mice, and the macro-scale stiffness of the artery was found to linearly correlate with the subendothelial matrix elastic modulus. Notably, we also found that with age, there exists an increase in the point-to-point variations in modulus across the subendothelial matrix, indicating non-uniform stiffening. Importantly, this heterogeneity is reversible with exercise. Given that vessel stiffening is known to cause aberrant endothelial cell behavior, and the spatial heterogeneities we find exist on a length scale much smaller than the size of a cell, these data suggest that further investigation in the heterogeneity of the subendothelial matrix elastic modulus is necessary to fully understand the effects of physiological matrix stiffening on cell function.
Collapse
Affiliation(s)
- Julie C Kohn
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853, United States
| | - Adeline Chen
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853, United States
| | - Stephanie Cheng
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853, United States
| | - Daniel R Kowal
- Department of Statistical Sciences, Cornell University, Ithaca, NY 14853, United States
| | - Michael R King
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853, United States
| | - Cynthia A Reinhart-King
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853, United States.
| |
Collapse
|
21
|
King JD, York SL, Saunders MM. Design, fabrication and characterization of a pure uniaxial microloading system for biologic testing. Med Eng Phys 2016; 38:411-6. [PMID: 26904918 DOI: 10.1016/j.medengphy.2016.01.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 01/05/2016] [Accepted: 01/31/2016] [Indexed: 12/18/2022]
Abstract
The field of mechanobiology aims to understand the role the mechanical environment plays in directing cell and tissue development, function and disease. The empirical aspect of the field requires the development of accurate, reproducible and reliable loading platforms that can apply microprecision mechanical load. In this study we designed, fabricated and characterized a pure uniaxial loading platform capable of testing small synthetic and organic specimens along a horizontal axis. The major motivation for platform development was in stimulating bone cells seeded on elastomeric substrates and soft tissue loading. The biological uses required the development of culturing fixtures and environmental chamber. The device utilizes commercial microactuators, load cells and a rail/carriage block system. Following fabrication, acceptable performance was verified by suture tensile testing.
Collapse
Affiliation(s)
- Jonathan D King
- Department of Biomedical Engineering, The University of Akron, 302 E Buchtel Ave, Akron, OH 44325-0302, United States.
| | - Spencer L York
- Department of Biomedical Engineering, The University of Akron, 302 E Buchtel Ave, Akron, OH 44325-0302, United States.
| | - Marnie M Saunders
- Department of Biomedical Engineering, The University of Akron, 302 E Buchtel Ave, Akron, OH 44325-0302, United States.
| |
Collapse
|
22
|
Jayyosi C, Coret M, Bruyère-Garnier K. Characterizing liver capsule microstructure via in situ bulge test coupled with multiphoton imaging. J Mech Behav Biomed Mater 2016; 54:229-43. [DOI: 10.1016/j.jmbbm.2015.09.031] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2015] [Revised: 09/23/2015] [Accepted: 09/24/2015] [Indexed: 10/22/2022]
|
23
|
Bancelin S, Lynch B, Bonod-Bidaud C, Ducourthial G, Psilodimitrakopoulos S, Dokládal P, Allain JM, Schanne-Klein MC, Ruggiero F. Ex vivo multiscale quantitation of skin biomechanics in wild-type and genetically-modified mice using multiphoton microscopy. Sci Rep 2015; 5:17635. [PMID: 26631592 PMCID: PMC4668561 DOI: 10.1038/srep17635] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2015] [Accepted: 11/02/2015] [Indexed: 02/02/2023] Open
Abstract
Soft connective tissues such as skin, tendon or cornea are made of about 90% of extracellular matrix proteins, fibrillar collagens being the major components. Decreased or aberrant collagen synthesis generally results in defective tissue mechanical properties as the classic form of Elhers-Danlos syndrome (cEDS). This connective tissue disorder is caused by mutations in collagen V genes and is mainly characterized by skin hyperextensibility. To investigate the relationship between the microstructure of normal and diseased skins and their macroscopic mechanical properties, we imaged and quantified the microstructure of dermis of ex vivo murine skin biopsies during uniaxial mechanical assay using multiphoton microscopy. We used two genetically-modified mouse lines for collagen V: a mouse model for cEDS harboring a Col5a2 deletion (a.k.a. pN allele) and the transgenic K14-COL5A1 mice which overexpress the human COL5A1 gene in skin. We showed that in normal skin, the collagen fibers continuously align with stretch, generating the observed increase in mechanical stress. Moreover, dermis from both transgenic lines exhibited altered collagen reorganization upon traction, which could be linked to microstructural modifications. These findings show that our multiscale approach provides new crucial information on the biomechanics of dermis that can be extended to all collagen-rich soft tissues.
Collapse
Affiliation(s)
- Stéphane Bancelin
- Laboratory for Optics and Biosciences, Ecole Polytechnique, CNRS, INSERM U1182, 91128 Palaiseau Cedex, FRANCE
| | - Barbara Lynch
- Solids Mechanics Laboratory Ecole Polytechnique, CNRS, Mines ParisTech, 91128 Palaiseau Cedex, FRANCE
| | - Christelle Bonod-Bidaud
- Institut de Génomique Fonctionnelle de Lyon, ENS-Lyon, CNRS UMR 5242, Université Lyon 1, 46 Allée d'Italie, 69364 Lyon, cedex 07 France
| | - Guillaume Ducourthial
- Laboratory for Optics and Biosciences, Ecole Polytechnique, CNRS, INSERM U1182, 91128 Palaiseau Cedex, FRANCE
| | | | - Petr Dokládal
- Centre for Mathematical Morphology, MINES ParisTech, PSL Research University, 35 rue St Honoré, 77300 Fontainebleau, France
| | - Jean-Marc Allain
- Solids Mechanics Laboratory Ecole Polytechnique, CNRS, Mines ParisTech, 91128 Palaiseau Cedex, FRANCE
| | - Marie-Claire Schanne-Klein
- Laboratory for Optics and Biosciences, Ecole Polytechnique, CNRS, INSERM U1182, 91128 Palaiseau Cedex, FRANCE
| | - Florence Ruggiero
- Institut de Génomique Fonctionnelle de Lyon, ENS-Lyon, CNRS UMR 5242, Université Lyon 1, 46 Allée d'Italie, 69364 Lyon, cedex 07 France
| |
Collapse
|
24
|
Ardila DC, Tamimi E, Danford FL, Haskett DG, Kellar RS, Doetschman T, Vande Geest JP. TGFβ2 differentially modulates smooth muscle cell proliferation and migration in electrospun gelatin-fibrinogen constructs. Biomaterials 2015; 37:164-73. [PMID: 25453947 PMCID: PMC4312204 DOI: 10.1016/j.biomaterials.2014.10.021] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2014] [Accepted: 10/02/2014] [Indexed: 01/14/2023]
Abstract
A main goal of tissue engineering is the development of scaffolds that replace, restore and improve injured tissue. These scaffolds have to mimic natural tissue, constituted by an extracellular matrix (ECM) support, cells attached to the ECM, and signaling molecules such as growth factors that regulate cell function. In this study we created electrospun flat sheet scaffolds using different compositions of gelatin and fibrinogen. Smooth muscle cells (SMCs) were seeded on the scaffolds, and proliferation and infiltration were evaluated. Additionally, different concentrations of Transforming Growth Factor-beta2 (TGFβ2) were added to the medium with the aim of elucidating its effect on cell proliferation, migration and collagen production. Our results demonstrated that a scaffold with a composition of 80% gelatin-20% fibrinogen is suitable for tissue engineering applications since it promotes cell growth and migration. The addition of TGFβ2 at low concentrations (≤ 1 ng/ml) to the culture medium resulted in an increase in SMC proliferation and scaffold infiltration, and in the reduction of collagen production. In contrast, TGFβ2 at concentrations >1 ng/ml inhibited cell proliferation and migration while stimulating collagen production. According to our results TGFβ2 concentration has a differential effect on SMC function and thus can be used as a biochemical modulator that can be beneficial for tissue engineering applications.
Collapse
Affiliation(s)
- Diana C Ardila
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| | - Ehab Tamimi
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| | - Forest L Danford
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| | - Darren G Haskett
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| | - Robert S Kellar
- Center for Bioengineering Innovation, Northern Arizona University, Flagstaff, AZ 86011, USA; Department of Mechanical Engineering, Northern Arizona University, Flagstaff, AZ 86011, USA; Department of Biological Sciences, Northern Arizona University, Flagstaff, AZ 86011, USA
| | - Tom Doetschman
- Department of Cellular and Molecular Medicine, The University of Arizona, Tucson, AZ 85721, USA; Sarver Heart Center, The University of Arizona, Tucson, AZ 85724, USA; BIO5 Institute for Biocollaborative Research, The University of Arizona, Tucson, AZ 85721, USA
| | - Jonathan P Vande Geest
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA; Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ 85721, USA; BIO5 Institute for Biocollaborative Research, The University of Arizona, Tucson, AZ 85721, USA; Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA.
| |
Collapse
|
25
|
Nierenberger M, Fargier G, Ahzi S, Rémond Y. Evolution of the three-dimensional collagen structure in vascular walls during deformation: an in situ mechanical testing under multiphoton microscopy observation. Biomech Model Mechanobiol 2014; 14:693-702. [DOI: 10.1007/s10237-014-0630-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Accepted: 10/24/2014] [Indexed: 10/24/2022]
|
26
|
Jayyosi C, Fargier G, Coret M, Bruyère-Garnier K. Photobleaching as a tool to measure the local strain field in fibrous membranes of connective tissues. Acta Biomater 2014; 10:2591-601. [PMID: 24568925 DOI: 10.1016/j.actbio.2014.02.031] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2013] [Revised: 02/10/2014] [Accepted: 02/14/2014] [Indexed: 12/16/2022]
Abstract
Connective tissues are complex structures which contain collagen and elastin fibers. These fiber-based structures have a great influence on material mechanical properties and need to be studied at the microscopic scale. Several microscopy techniques have been developed in order to image such microstructures; among them are two-photon excited fluorescence microscopy and second harmonic generation. These observations have been coupled with mechanical characterization to link microstructural kinematics to macroscopic material parameter evolution. In this study, we present a new approach to measure local strain in soft biological tissues using a side-effect of fluorescence microscopy: photobleaching. Controlling the loss of fluorescence induced by photobleaching, we create a pattern on our sample that we can monitor during mechanical loading. The image analysis allows three-dimensional displacements of the patterns at various loading levels to be computed. Then, local strain distribution is derived using the finite element discretization on a four-node element mesh created from our photobleached pattern. Photobleaching tests on a human liver capsule have revealed that this technique is non-destructive and does not have any impact on mechanical properties. This method is likely to have other applications in biological material studies, considering that all collagen-elastin fiber-based biological tissues possess autofluorescence properties and thus can be photobleached.
Collapse
Affiliation(s)
- C Jayyosi
- Université de Lyon, F-69622 Lyon;IFSTTAR, LBMC, UMR-T9406; Université Lyon 1, France.
| | - G Fargier
- Plateforme IVTV, CNRS, 36 Avenue Guy de Collongue, Bâtiment G8, 69134 Ecully Cedex, France
| | - M Coret
- LUNAM Université, GEM, UMR CNRS 6183, Ecole Centrale de Nantes, Université de Nantes, France
| | - K Bruyère-Garnier
- Université de Lyon, F-69622 Lyon;IFSTTAR, LBMC, UMR-T9406; Université Lyon 1, France
| |
Collapse
|
27
|
Chen H, Slipchenko MN, Liu Y, Zhao X, Cheng JX, Lanir Y, Kassab GS. Biaxial deformation of collagen and elastin fibers in coronary adventitia. J Appl Physiol (1985) 2013; 115:1683-93. [PMID: 24092692 DOI: 10.1152/japplphysiol.00601.2013] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
The microstructural deformation-mechanical loading relation of the blood vessel wall is essential for understanding the overall mechanical behavior of vascular tissue in health and disease. We employed simultaneous mechanical loading-imaging to quantify in situ deformation of individual collagen and elastin fibers on unstained fresh porcine coronary adventitia under a combination of vessel inflation and axial extension loading. Specifically, the specimens were imaged under biaxial loads to study microscopic deformation-loading behavior of fibers in conjunction with morphometric measurements at the zero-stress state. Collagen fibers largely orientate in the longitudinal direction, while elastin fibers have major orientation parallel to collagen, but with additional orientation angles in each sublayer of the adventitia. With an increase of biaxial load, collagen fibers were uniformly stretched to the loading direction, while elastin fibers gradually formed a network in sublayers, which strongly depended on the initial arrangement. The waviness of collagen decreased more rapidly at a circumferential stretch ratio of λθ = 1.0 than at λθ = 1.5, while most collagen became straightened at λθ = 1.8. These microscopic deformations imply that the longitudinally stiffer adventitia is a direct result of initial fiber alignment, and the overall mechanical behavior of the tissue is highly dependent on the corresponding microscopic deformation of fibers. The microstructural deformation-loading relation will serve as a foundation for micromechanical models of the vessel wall.
Collapse
Affiliation(s)
- Huan Chen
- Department of Biomedical Engineering, Indiana University Purdue University Indianapolis, Indianapolis, Indiana
| | | | | | | | | | | | | |
Collapse
|
28
|
Fata B, Carruthers CA, Gibson G, Watkins SC, Gottlieb D, Mayer JE, Sacks MS. Regional structural and biomechanical alterations of the ovine main pulmonary artery during postnatal growth. J Biomech Eng 2013; 135:021022. [PMID: 23445067 DOI: 10.1115/1.4023389] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The engineering foundation for novel approaches for the repair of congenital defects that involve the main pulmonary artery (PA) must rest on an understanding of changes in the structure-function relationship that occur during postnatal maturation. In the present study, we quantified the postnatal growth patterns in structural and biomechanical behavior in the ovine PA in the juvenile and adult stages. The biaxial mechanical properties and collagen and elastin fiber architecture were studied in four regions of the PA wall, with the collagen recruitment of the medial region analyzed using a custom biaxial mechanical-multiphoton microscopy system. Circumferential residual strain was also quantified at the sinotubular junction and bifurcation locations, which delimit the PA. The PA wall demonstrated significant mechanical anisotropy, except in the posterior region where it was nearly isotropic. Overall, we observed only moderate changes in regional mechanical properties with growth. We did observe that the medial and lateral locations experience a moderate increase in anisotropy. There was an average of about 24% circumferential residual stain present at the luminal surface in the juvenile stage that decreased to 16% in the adult stage with a significant decrease at the bifurcation, implying that the PA wall remodels toward the bifurcation with growth. There were no measurable changes in collagen and elastin content of the tunica media with growth. On average, the collagen fiber recruited more rapidly with strain in the adult compared to the juvenile. Interestingly, the PA thickness remained constant with growth. When this fact is combined with the observed stable overall mechanical behavior and increase in vessel diameter with growth, a simple Laplace Law wall stress estimate suggests an increase in effective PA wall stress with postnatal maturation. This observation is contrary to the accepted theory of maintenance of homeostatic stress levels in the regulation of vascular function and suggests alternative mechanisms regulate postnatal somatic growth. Understanding the underlying mechanisms, incorporating important structural features during growth, will help to improve our understanding of congenital defects of the PA and lay the basis for functional duplication in their repair and replacement.
Collapse
Affiliation(s)
- Bahar Fata
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15219, USA
| | | | | | | | | | | | | |
Collapse
|
29
|
Hadi MF, Barocas VH. Microscale fiber network alignment affects macroscale failure behavior in simulated collagen tissue analogs. J Biomech Eng 2013; 135:021026. [PMID: 23445071 DOI: 10.1115/1.4023411] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A tissue's microstructure determines its failure properties at larger length scales, however, the specific relationship between microstructure and macroscopic failure in native and engineered soft tissues (such as capsular ligaments, aortic aneurysms, or vascular grafts) has proven elusive. In this study, variations in the microscale fiber alignment in collagen gel tissue analogs were modeled in order to understand their effects on macroscale damage and failure outcomes. The study employed a multiscale finite-element (FE) model for damage and failure in collagen-based materials. The model relied on microstructural representative volume elements (RVEs) that consisted of stochastically-generated networks of discrete type-I collagen fibers. Fiber alignment was varied within RVEs and between layers of RVEs in a macroscopic FE model of a notched dogbone geometry. The macroscale stretch and the microscale response of fibers for each of the differently aligned cases were compared as the dogbone was uniaxially extended to failure. Networks with greater fiber alignment parallel to the direction of extension failed at smaller strains (with a 6-22% reduction in the Green strain at failure), however, at greater grip forces (a 28-60% increase) than networks with fibers aligned perpendicular to the extension. Alternating layers of crisscrossed network alignments (aligned ±45 deg to the direction of extension) failed at smaller strains but at greater grip forces than those created using one fiber alignment type. In summary, variations in microscale structure via fiber alignment produced different macroscale failure trends. To conclude, these findings may be significant in the realm of tissue engineering and in soft tissue biomechanics.
Collapse
Affiliation(s)
- Mohammad F Hadi
- Department of Biomedical Engineering, University of Minnesota, 312 Church Street SE, Minneapolis, MN 55455, USA.
| | | |
Collapse
|
30
|
Haskett D, Azhar M, Utzinger U, Vande Geest JP. Progressive alterations in microstructural organization and biomechanical response in the ApoE mouse model of aneurysm. BIOMATTER 2013; 3:24648. [PMID: 23628871 PMCID: PMC3749278 DOI: 10.4161/biom.24648] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
AAA is a complex disease that leads to a localized dilation of the infrarenal aorta that develops over years. Longitudinal information in humans has been difficult to obtain for this disease, therefore mouse models have become increasingly used to study the development of AAAs. The objective of this study was to determine any changes that occur in the biomechanical response and fiber microstructure in the ApoE−/− AngII mouse model of aneurysm during disease progression. Adult ApoE−/− AngII infused mice along with wild-type controls were taken at 14 and 28 d. Aortas were excised and tested simultaneously for biaxial mechanical response and ECM organization. Data sets were fit to a Fung-type constitutive model to give peak strains and stiffness values. Images from two photon microscopy were quantified in order to assess the preferred fiber alignment and degree of fiber orientation. Biomechanical results found significant differences that were present at 14 d had returned to normal by 28 d along with significant changes in fiber orientation and dispersion indicating remodeling occurring within the aneurysmal wall. This return of some of the normal biomechanical function, in addition the continuing changes that occur in the microstructure suggest a restorative response that occurs in the ApoE−/− AngII infused model after the initial aneurysm formation.
Collapse
Affiliation(s)
- Darren Haskett
- Graduate Interdisciplinary Program of Biomedical Engineering; University of Arizona; Tucson, AZ USA
| | - Mohamad Azhar
- Developmental Biology and Neonatal Medicine Program, Herman B. Wells Center for Pediatric Research, Indiana University School of Medicine, Indianapolis, IN USA
| | - Urs Utzinger
- Graduate Interdisciplinary Program of Biomedical Engineering; University of Arizona; Tucson, AZ USA; BIO5 Institute; University of Arizona; Tucson, AZ USA; Department of Biomedical Engineering; University of Arizona; Tucson, AZ USA
| | - Jonathan P Vande Geest
- Graduate Interdisciplinary Program of Biomedical Engineering; University of Arizona; Tucson, AZ USA; BIO5 Institute; University of Arizona; Tucson, AZ USA; Department of Biomedical Engineering; University of Arizona; Tucson, AZ USA; Department of Aerospace and Mechanical Engineering; University of Arizona; Tucson, AZ USA
| |
Collapse
|
31
|
Sugita S, Matsumoto T. Quantitative measurement of the distribution and alignment of collagen fibers in unfixed aortic tissues. J Biomech 2013; 46:1403-7. [DOI: 10.1016/j.jbiomech.2013.02.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2012] [Revised: 11/16/2012] [Accepted: 02/05/2013] [Indexed: 12/19/2022]
|
32
|
Keyes JT, Lockwood DR, Utzinger U, Montilla LG, Witte RS, Vande Geest JP. Comparisons of planar and tubular biaxial tensile testing protocols of the same porcine coronary arteries. Ann Biomed Eng 2012; 41:1579-91. [PMID: 23132151 DOI: 10.1007/s10439-012-0679-0] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2012] [Accepted: 10/09/2012] [Indexed: 01/13/2023]
Abstract
To identify the orthotropic biomechanical behavior of arteries, researchers typically perform stretch-pressure-inflation tests on tube-form arteries or planar biaxial testing of splayed sections. We examined variations in finite element simulations (FESs) driven from planar or tubular testing of the same coronary arteries to determine what differences exist when picking one testing technique vs. another. Arteries were tested in tube-form first, then tested in planar-form, and fit to a Fung-type strain energy density function. Afterwards, arteries were modeled via finite element analysis looking at stress and displacement behavior in different scenarios (e.g., tube FESs with tube- or planar-driven constitutive models). When performing FESs of tube inflation from a planar-driven constitutive model, pressure-diameter results had an error of 12.3% compared to pressure-inflation data. Circumferential stresses were different between tube- and planar-driven pressure-inflation models by 50.4% with the planar-driven model having higher stresses. This reduced to 3.9% when rolling the sample to a tube first with planar-driven properties, then inflating with tubular-driven properties. Microstructure showed primarily axial orientation in the tubular and opening-angle configurations. There was a shift towards the circumferential direction upon flattening of 8.0°. There was also noticeable collagen uncrimping in the flattened tissue.
Collapse
Affiliation(s)
- Joseph T Keyes
- Graduate Interdisciplinary Program in Biomedical Engineering, The University of Arizona, P.O. Box 210119, Tucson, AZ 85721-0119, USA
| | | | | | | | | | | |
Collapse
|
33
|
A method for the quantification of the pressure dependent 3D collagen configuration in the arterial adventitia. J Struct Biol 2012; 180:335-42. [DOI: 10.1016/j.jsb.2012.06.007] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2012] [Revised: 05/30/2012] [Accepted: 06/12/2012] [Indexed: 11/22/2022]
|
34
|
Keyes JT, Lockwood DR, Simon BR, Vande Geest JP. Deformationally dependent fluid transport properties of porcine coronary arteries based on location in the coronary vasculature. J Mech Behav Biomed Mater 2012; 17:296-306. [PMID: 23127633 DOI: 10.1016/j.jmbbm.2012.10.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2012] [Revised: 09/17/2012] [Accepted: 10/01/2012] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Understanding coronary artery mass transport allows researchers to better comprehend how drugs or proteins move through, and deposit into, the arterial wall. Characterizing how the convective component of transport changes based on arterial location could be useful to better understand how molecules distribute in different locations in the coronary vasculature. METHODS AND RESULTS We measured the mechanical properties and wall fluid flux transport properties of de-endothelialized (similar to post-stenting or angioplasty) left anterior descending (LADC) and right (RC) porcine coronary arteries along their arterial lengths. Multiphoton microscopy was used to determine microstructural differences. Proximal LADC regions had a higher circumferential stiffness than all other regions. Permeability decreased by 198% in the LADC distal region compared to other LADC regions. The RC artery showed a decrease of 46.9% from the proximal to middle region, and 51.7% from the middle to distal regions. The porosity increased in the intima between pressure states, without differences through the remainder of the arterial thickness. CONCLUSIONS We showed that the permeabilities and mechanical properties do vary in the coronary vasculature. With variations in mechanical properties, overexpansion of stents can occur more easily while variations in permeability may lead to altered transport based on location.
Collapse
Affiliation(s)
- Joseph T Keyes
- Graduate Interdisciplinary Program in Biomedical Engineering 1657 E Helen St, The University of Arizona, Tucson, AZ 85721, USA.
| | | | | | | |
Collapse
|
35
|
Hofmann MC, Whited BM, Criswell T, Rylander MN, Rylander CG, Soker S, Wang G, Xu Y. A fiber-optic-based imaging system for nondestructive assessment of cell-seeded tissue-engineered scaffolds. Tissue Eng Part C Methods 2012; 18:677-87. [PMID: 22439610 DOI: 10.1089/ten.tec.2011.0490] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
A major limitation in tissue engineering is the lack of nondestructive methods that assess the development of tissue scaffolds undergoing preconditioning in bioreactors. Due to significant optical scattering in most scaffolding materials, current microscope-based imaging methods cannot "see" through thick and optically opaque tissue constructs. To address this deficiency, we developed a fiber-optic-based imaging method that is capable of nondestructive imaging of fluorescently labeled cells through a thick and optically opaque scaffold, contained in a bioreactor. This imaging modality is based on the local excitation of fluorescent cells, the acquisition of fluorescence through the scaffold, and fluorescence mapping based on the position of the excitation light. To evaluate the capability and accuracy of the imaging system, human endothelial cells (ECs), stably expressing green fluorescent protein (GFP), were imaged through a fibrous scaffold. Without sacrificing the scaffolds, we nondestructively visualized the distribution of GFP-labeled cells through a ~500 μm thick scaffold with cell-level resolution and distinct localization. These results were similar to control images obtained using an optical microscope with direct line-of-sight access. Through a detailed quantitative analysis, we demonstrated that this method achieved a resolution on the order of 20-30 μm, with 10% or less deviation from standard optical microscopy. Furthermore, we demonstrated that the penetration depth of the imaging method exceeded that of confocal laser scanning microscopy by more than a factor of 2. Our imaging method also possesses a working distance (up to 8 cm) much longer than that of a standard confocal microscopy system, which can significantly facilitate bioreactor integration. This method will enable the nondestructive monitoring of ECs seeded on the lumen of a tissue-engineered vascular graft during preconditioning in vitro, as well as for other tissue-engineered constructs in the future.
Collapse
Affiliation(s)
- Matthias C Hofmann
- Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, VA 24061, USA
| | | | | | | | | | | | | | | |
Collapse
|
36
|
Altered tissue behavior of a non-aneurysmal descending thoracic aorta in the mouse model of Marfan syndrome. Cell Tissue Res 2012; 347:267-77. [PMID: 22105919 DOI: 10.1007/s00441-011-1270-y] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2011] [Accepted: 10/24/2011] [Indexed: 01/01/2023]
Abstract
Aortic aneurysm is predominantly found in the ascending aorta in patients with Marfan syndrome (MFS). However, descending aortic disease has emerged as a problem since people are living longer because of improved medical and surgical management of the ascending aorta. Diagnostic procedures before disease onset and the mechanisms involved in the transition of normal aortic tissue to aneurysm remain unclear. We determined signs of descending aortic disease before disease onset in mice with a mutation in the fibrillin 1 gene (Fbn1(+/C1039G)), a validated mouse model of disease susceptibility and progression of aortic aneurysm of MFS. We analyzed a tubular unfixed non-aneurysmal descending thoracic aorta from 8-month-old wild-type and Fbn1(+/C1039G) mice by a tubular biaxial tester that works in conjunction with a two-photon nonlinear microscope. Fbn1(+/C1039G) mouse aorta was more compliant in the circumferential direction. Two-photon imaging showed defective organization of adventitial collagen fibers in the pressurized aortas of Fbn1(+/C1039G) mice. Moreover, disruption in the elastic lamina was noted in the absence of aneurysms in pressurized aortas but not unpressurized aortas of Fbn1(+/C1039G) mice. At the molecular level, this altered tissue behavior in non-aneurysmal descending aortas of Fbn1(+/C1039G) mice was accompanied by an increasing trend of canonical but not noncanonical, transforming growth factor-β (TGFβ) signaling. Finally, assays of in vitro collagen lattice formation in mouse wild-type and TGFβ1-deficient embryonic fibroblasts indicate that TGFβ1 can regulate collagen organization. The ability to reveal the presence of altered biomechanics and microstructure coupled with subtle changes in TGFβ signaling provides a novel surrogate measure of tissue susceptibility to aneurysm before disease onset.
Collapse
|
37
|
Haskett D, Speicher E, Fouts M, Larson D, Azhar M, Utzinger U, Vande Geest J. The effects of angiotensin II on the coupled microstructural and biomechanical response of C57BL/6 mouse aorta. J Biomech 2011; 45:772-9. [PMID: 22196971 DOI: 10.1016/j.jbiomech.2011.11.017] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
RATIONALE Abdominal aortic aneurysm (AAA) is a complex disease that leads to a localized dilation of the infrarenal aorta, the rupture of which is associated with significant morbidity and mortality. Animal models of AAA can be used to study how changes in the microstructural and biomechanical behavior of aortic tissues develop as disease progresses in these animals. We chose here to investigate the effect of angiotensin II (AngII) in C57BL/6 mice as a first step towards understanding how such changes occur in the established ApoE(-/-) AngII infused mouse model of AAA. OBJECTIVE The objective of this study was to utilize a recently developed device in our laboratory to determine how the microstructural and biomechanical properties of AngII-infused C57BL/6 wildtype mouse aorta change following 14 days of AngII infusion. METHODS C57BL/6 wildtype mice were infused with either saline or AngII for 14 day. Aortas were excised and tested using a device capable of simultaneously characterizing the biaxial mechanical response and load-dependent (unfixed, unfrozen) extracellular matrix organization of mouse aorta (using multiphoton microscopy). Peak strains and stiffness values were compared across experimental groups, and both datasets were fit to a Fung-type constitutive model. The mean mode and full width at half maximum (FWHM) of fiber histograms from two photon microscopy were quantified in order to assess the preferred fiber distribution and degree of fiber splay, respectively. RESULTS The axial stiffness of all mouse aorta was found to be an order of magnitude larger than the circumferential stiffness. The aortic diameter was found to be significantly increased for the AngII infused mice as compared to saline infused control (p=0.026). Aneurysm, defined as a percent increase in maximum diameter of 30% (defined with respect to saline control), was found in 3 of the 6 AngII infused mice. These three mice displayed adventitial collagen that lacked characteristic fiber crimp. The biomechanical response in the AngII infused mice showed significantly reduced circumferential compliance. We also noticed that the ability of the adventitial collagen fibers in AngII infused mice to disperse in reaction to circumferential loading was suppressed. CONCLUSIONS Collagen remodeling is present following 14 days of AngII infusion in C57BL/6 mice. Aneurysmal development occurred in 50% of our AngII infused mice, and these dilatations were accompanied with adventitial collagen remodeling and decreased circumferential compliance.
Collapse
Affiliation(s)
- Darren Haskett
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721-0119, USA
| | | | | | | | | | | | | |
Collapse
|