1
|
Depenveiller C, Baud S, Belloy N, Bochicchio B, Dandurand J, Dauchez M, Pepe A, Pomès R, Samouillan V, Debelle L. Structural and physical basis for the elasticity of elastin. Q Rev Biophys 2024; 57:e3. [PMID: 38501287 DOI: 10.1017/s0033583524000040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
Elastin function is to endow vertebrate tissues with elasticity so that they can adapt to local mechanical constraints. The hydrophobicity and insolubility of the mature elastin polymer have hampered studies of its molecular organisation and structure-elasticity relationships. Nevertheless, a growing number of studies from a broad range of disciplines have provided invaluable insights, and several structural models of elastin have been proposed. However, many questions remain regarding how the primary sequence of elastin (and the soluble precursor tropoelastin) governs the molecular structure, its organisation into a polymeric network, and the mechanical properties of the resulting material. The elasticity of elastin is known to be largely entropic in origin, a property that is understood to arise from both its disordered molecular structure and its hydrophobic character. Despite a high degree of hydrophobicity, elastin does not form compact, water-excluding domains and remains highly disordered. However, elastin contains both stable and labile secondary structure elements. Current models of elastin structure and function are drawn from data collected on tropoelastin and on elastin-like peptides (ELPs) but at the tissue level, elasticity is only achieved after polymerisation of the mature elastin. In tissues, the reticulation of tropoelastin chains in water defines the polymer elastin that bears elasticity. Similarly, ELPs require polymerisation to become elastic. There is considerable interest in elastin especially in the biomaterials and cosmetic fields where ELPs are widely used. This review aims to provide an up-to-date survey of/perspective on current knowledge about the interplay between elastin structure, solvation, and entropic elasticity.
Collapse
Affiliation(s)
- Camille Depenveiller
- UMR URCA/CNRS 7369, Matrice Extracellulaire et Dynamique Cellulaire (MEDyC), UFR Sciences Exactes et Naturelles, SFR CAP Santé, Université de Reims Champagne-Ardenne, Reims, France
- Unité de Génie Enzymatique et Cellulaire UMR 7025 CNRS, Université de Picardie Jules Verne, Amiens, France
| | - Stéphanie Baud
- UMR URCA/CNRS 7369, Matrice Extracellulaire et Dynamique Cellulaire (MEDyC), UFR Sciences Exactes et Naturelles, SFR CAP Santé, Université de Reims Champagne-Ardenne, Reims, France
| | - Nicolas Belloy
- UMR URCA/CNRS 7369, Matrice Extracellulaire et Dynamique Cellulaire (MEDyC), UFR Sciences Exactes et Naturelles, SFR CAP Santé, Université de Reims Champagne-Ardenne, Reims, France
| | - Brigida Bochicchio
- Laboratory of Bioinspired Materials, Department of Science, University of Basilicata, Potenza, Italy
| | - Jany Dandurand
- CIRIMAT UMR 5085, Université Paul Sabatier, Université de Toulouse, Toulouse, France
| | - Manuel Dauchez
- UMR URCA/CNRS 7369, Matrice Extracellulaire et Dynamique Cellulaire (MEDyC), UFR Sciences Exactes et Naturelles, SFR CAP Santé, Université de Reims Champagne-Ardenne, Reims, France
| | - Antonietta Pepe
- Laboratory of Bioinspired Materials, Department of Science, University of Basilicata, Potenza, Italy
| | - Régis Pomès
- Molecular Medicine, Hospital for Sick Children, Toronto, ON, Canada
- Department of Biochemistry, University of Toronto, Toronto, ON, Canada
| | - Valérie Samouillan
- CIRIMAT UMR 5085, Université Paul Sabatier, Université de Toulouse, Toulouse, France
| | - Laurent Debelle
- UMR URCA/CNRS 7369, Matrice Extracellulaire et Dynamique Cellulaire (MEDyC), UFR Sciences Exactes et Naturelles, SFR CAP Santé, Université de Reims Champagne-Ardenne, Reims, France
| |
Collapse
|
2
|
McCarthy CM, McKevitt KL, Connolly SA, Andersson I, Leahy FC, Egan S, Moloney MA, Kavanagh EG, Peirce C, Cunnane EM, McGourty KD, Walsh MT, Mulvihill JJE. Microindentation of fresh soft biological tissue: A rapid tissue sectioning and mounting protocol. PLoS One 2024; 19:e0297618. [PMID: 38422111 PMCID: PMC10903917 DOI: 10.1371/journal.pone.0297618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 01/03/2024] [Indexed: 03/02/2024] Open
Abstract
Microindentation of fresh biological tissues is necessary for the creation of 3D biomimetic models that accurately represent the native extracellular matrix microenvironment. However, tissue must first be precisely sectioned into slices. Challenges exist in the preparation of fresh tissue slices, as they can tear easily and must be processed rapidly in order to mitigate tissue degradation. In this study, we propose an optimised mounting condition for microindentation and demonstrate that embedding tissue in a mixture of 2.5% agarose and 1.5% gelatin is the most favourable method of tissue slice mounting for microindentation. This protocol allows for rapid processing of fresh biological tissue and is applicable to a variety of tissue types.
Collapse
Affiliation(s)
- Clíona M. McCarthy
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland
- School of Engineering, University of Limerick, Limerick, Ireland
| | - Kevin L. McKevitt
- Department of Vascular & Endovascular Surgery, University Hospital Limerick, Limerick, Ireland
| | - Sinéad A. Connolly
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland
- School of Engineering, University of Limerick, Limerick, Ireland
| | - Isabel Andersson
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland
- School of Engineering, University of Limerick, Limerick, Ireland
| | - Fiona C. Leahy
- Department of Vascular & Endovascular Surgery, University Hospital Limerick, Limerick, Ireland
| | - Siobhan Egan
- Department of Colorectal Surgery, University Hospital Limerick, Limerick, Ireland
| | - Michael A. Moloney
- Department of Vascular & Endovascular Surgery, University Hospital Limerick, Limerick, Ireland
| | - Eamon G. Kavanagh
- Department of Vascular & Endovascular Surgery, University Hospital Limerick, Limerick, Ireland
| | - Colin Peirce
- Department of Colorectal Surgery, University Hospital Limerick, Limerick, Ireland
| | - Eoghan M. Cunnane
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland
- School of Engineering, University of Limerick, Limerick, Ireland
- Health Research Institute, University of Limerick, Limerick, Ireland
| | - Kieran D. McGourty
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland
- School of Engineering, University of Limerick, Limerick, Ireland
- School of Chemical Sciences, University of Limerick, Limerick, Ireland
| | - Michael T. Walsh
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland
- School of Engineering, University of Limerick, Limerick, Ireland
- Health Research Institute, University of Limerick, Limerick, Ireland
| | - John J. E. Mulvihill
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland
- School of Engineering, University of Limerick, Limerick, Ireland
- Health Research Institute, University of Limerick, Limerick, Ireland
| |
Collapse
|
3
|
Zhang W, Jadidi M, Razian SA, Holzapfel GA, Kamenskiy A, Nordsletten DA. A viscoelastic constitutive model for human femoropopliteal arteries. Acta Biomater 2023; 170:68-85. [PMID: 37699504 PMCID: PMC10802972 DOI: 10.1016/j.actbio.2023.09.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 09/06/2023] [Accepted: 09/07/2023] [Indexed: 09/14/2023]
Abstract
High failure rates present challenges for surgical and interventional therapies for peripheral artery disease of the femoropopliteal artery (FPA). The FPA's demanding biomechanical environment necessitates complex interactions with repair devices and materials. While a comprehensive understanding of the FPA's mechanical characteristics could improve medical treatments, the viscoelastic properties of these muscular arteries remain poorly understood, and the constitutive model describing their time-dependent behavior is absent. We introduce a new viscoelastic constitutive model for the human FPA grounded in its microstructural composition. The model is capable of detailing the contributions of each intramural component to the overall viscoelastic response. Our model was developed utilizing fractional viscoelasticity and tested using biaxial experimental data with hysteresis and relaxation collected from 10 healthy human subjects aged 57 to 65 and further optimized for high throughput and automation. The model accurately described the experimental data, capturing significant nonlinearity and hysteresis that were particularly pronounced circumferentially, and tracked the contribution of passive smooth muscle cells to viscoelasticity that was twice that of the collagen fibers. The high-throughput parameter estimation procedure we developed included a specialized objective function and modifications to enhance convergence for the common exponential-type fiber laws, facilitating computational implementation. Our new model delineates the time-dependent behavior of human FPAs, which will improve the fidelity of computational simulations investigating device-artery interactions and contribute to their greater physical accuracy. Moreover, it serves as a useful tool to investigate the contribution of arterial constituents to overall tissue viscoelasticity, thereby expanding our knowledge of arterial mechanophysiology. STATEMENT OF SIGNIFICANCE: The demanding biomechanical environment of the femoropopliteal artery (FPA) necessitates complex interactions with repair devices and materials, but the viscoelastic properties of these muscular arteries remain poorly understood with the constitutive model describing their time-dependent behavior being absent. We hereby introduce the first viscoelastic constitutive model for the human FPA grounded in its microstructures. This model was tested using biaxial mechanical data collected from 10 healthy human subjects between the ages of 57 to 65. It can detail the contributions of each intramural component to the overall viscoelastic response, showing that the contribution of passive smooth muscle cells to viscoelasticity is twice that of collagen fibers. The usefulness of this model as tool to better understand arterial mechanophysiology was demonstrated.
Collapse
Affiliation(s)
- Will Zhang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
| | - Majid Jadidi
- Department of Biomechanics, University of Nebraska at Omaha, Omaha, NE, USA.
| | | | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz Univerisity of Technology, Graz, Austria; Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim, Norway.
| | - Alexey Kamenskiy
- Department of Biomechanics, University of Nebraska at Omaha, Omaha, NE, USA.
| | - David A Nordsletten
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA; Division of Biomedical Engineering and Imaging Sciences, Department of Biomedical Engineering, King's College London, London, UK.
| |
Collapse
|
4
|
de Guzman RC, Meer AS, Mathews AA, Israel AR, Moses MT, Sams CM, Deegan DB. Reduced fibrous capsule elastic fibers from biologic ECM-enveloped CIEDs in minipigs, supported with a novel compression mechanics model. Biomed Mater Eng 2022:BME221488. [PMID: 36617774 DOI: 10.3233/bme-221488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
BACKGROUND Fibrous capsules (Fb) in response to cardiovascular implantable electronic devices (CIEDs), including a pacemaker (P) system, can produce patient discomfort and difficulties in revision surgery due partially to their increased compressive strength, previously linked to elevated tissue fibers. OBJECTIVE A preliminary study to quantify structural proteins, determine if biologic extracellular matrix-enveloped CIEDs (PECM) caused differential Fb properties, and to implement a realistic mechanical model. METHODS Retrieved Fb (-P and -PECM) from minipigs were subjected to biomechanical (shear oscillation and uniaxial compression) and histological (collagen I and elastin) analyses. RESULTS Fb-PECM showed significant decreases compared to Fb-P in: low strain-loss modulus (390 vs. 541 Pa) across angular frequencies, high strain-compressive elastic modulus (1043 vs. 2042 kPa), and elastic fiber content (1.92 vs. 3.15 μg/mg tissue). Decreases in elastin were particularly noted closer to the implant's surface (Fb-PECM = 71% vs. Fb-P = 143% relative to dermal elastin at mid-tangential sections) and verified with a solid mechanics hyperelasticity with direction-dependent fiber viscoelasticity compression simulation (r2 ≥ 98.9%). CONCLUSIONS The biologic envelope composed of decellularized porcine small intestine submucosa ECM for CIEDs promoted fibrous tissues with less elastic fibers. Novel compression modeling analyses directly correlated this singular reduction to more desirable subcutaneous tissue mechanics.
Collapse
Affiliation(s)
- Roche C de Guzman
- Bioengineering Program, Department of Engineering, Hofstra University, Hempstead, NY, USA
| | - Allison S Meer
- Bioengineering Program, Department of Engineering, Hofstra University, Hempstead, NY, USA.,Department of Biology, Hofstra University, Hempstead, NY, USA
| | - Aidan A Mathews
- Bioengineering Program, Department of Engineering, Hofstra University, Hempstead, NY, USA.,Department of Biology, Hofstra University, Hempstead, NY, USA
| | - Atara R Israel
- Bioengineering Program, Department of Engineering, Hofstra University, Hempstead, NY, USA
| | - Michael T Moses
- Bioengineering Program, Department of Engineering, Hofstra University, Hempstead, NY, USA
| | - Clarence M Sams
- Bioengineering Program, Department of Engineering, Hofstra University, Hempstead, NY, USA
| | | |
Collapse
|
5
|
Osorio R, Asady S, Toledano-Osorio M, Toledano M, Bueno JM, Martínez-Ojeda RM, Osorio E. Biomimetic Remineralization of an Extracellular Matrix Collagen Membrane for Bone Regeneration. Polymers (Basel) 2022; 14:polym14163274. [PMID: 36015534 PMCID: PMC9415104 DOI: 10.3390/polym14163274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 08/04/2022] [Accepted: 08/08/2022] [Indexed: 11/16/2022] Open
Abstract
Natural extracellular matrix (ECM) collagen membranes are frequently used for bone regeneration procedures. Some disadvantages, such as rapid degradation and questionable mechanical properties, limit their clinical use. These membranes have a heterologous origin and may proceed from different tissues. Biomineralization is a process in which hydroxyapatite deposits mainly in collagen fibrils of the matrices. However, when this deposition occurs on the ECM, its mechanical properties are increased, facilitating bone regeneration. The objective of the present research is to ascertain if different membranes from distinct origins may undergo biomineralization. Nanomechanical properties, scanning electron (SEM) and multiphoton (MP) microscopy imaging were performed in three commercially available ECMs before and after immersion in simulated body fluid solution for 7 and 21 d. The matrices coming from porcine dermis increased their nanomechanical properties and they showed considerable mineralization after 21 d, as observed in structural changes detected through SEM and MP microscopy. It is hypothesized that the more abundant crosslinking and the presence of elastin fibers within this membrane explains the encountered favorable behavior.
Collapse
Affiliation(s)
- Raquel Osorio
- Faculty of Dentistry, University of Granada, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| | - Samara Asady
- Faculty of Dentistry, University of Granada, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
- Medicina Clínica y Salud Pública Programme, University of Granada, 18071 Granada, Spain
| | - Manuel Toledano-Osorio
- Faculty of Dentistry, University of Granada, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
- Medicina Clínica y Salud Pública Programme, University of Granada, 18071 Granada, Spain
- Correspondence: ; Tel.: +34-958-243-789
| | - Manuel Toledano
- Faculty of Dentistry, University of Granada, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| | - Juan M. Bueno
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Ed. 34), 30100 Murcia, Spain
| | - Rosa M. Martínez-Ojeda
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Ed. 34), 30100 Murcia, Spain
| | - Estrella Osorio
- Medicina Clínica y Salud Pública Programme, University of Granada, 18071 Granada, Spain
| |
Collapse
|
6
|
Mathur VP, Atif M, Duggal I, Tewari N, Duggal R, Chawla A. Reporting guidelines for in-silico studies using finite element analysis in medicine (RIFEM). COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 216:106675. [PMID: 35152164 DOI: 10.1016/j.cmpb.2022.106675] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 01/08/2022] [Accepted: 01/30/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND To the best of our knowledge, there are no reporting guidelines for design, conduct and reporting of Finite Element studies in health sciences. We intend to propose specific and detailed guidelines for reporting these studies. METHOD After recognizing the need to have uniform guidelines for reporting of finite element analysis in medicine and dentistry, a group of 5 researchers working on FEA as their research area met in the summer of 2020 and drafted the methodology for the development of such guidelines. Each researcher individually made a list of major headings required for reporting these studies and met again in September 2020 to finalize the domains. Subsequently, sub headings and details were charted. The draft list of items for reporting the guidelines were presented to a larger team of 15 experts and some changes were further made based on their inputs. RESULTS The guidelines entail seven major domains and their sub-domains, including parameters for model structure, segmentation, mesh structure, force application and model validation, etc. This checklist aims to improvise the reporting and consistency of FEA studies. CONCLUSION We hope that the usage and adoption of these guidelines by the scientific community would result in more thoughtful and uniform documentation. Also, the confidence in the results would be enhanced through model reproducibility, reusability and accountability. The proposed guidelines were named as 'Reporting of in-silico studies using finite element analysis in medicine' and the term 'RIFEM' was used as acronym.
Collapse
Affiliation(s)
- Vijay Prakash Mathur
- Pedodontics and Preventive Dentistry, Centre for Dental Education and Research, All India Institute of Medical Sciences, 6th Floor, New Delhi 110029, India
| | - Mohammad Atif
- Pedodontics and Preventive Dentistry, Centre for Dental Education and Research, All India Institute of Medical Sciences, 6th Floor, New Delhi 110029, India.
| | - Isha Duggal
- Orthodontics and Dentofacial Deformities, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi 110029, India
| | - Nitesh Tewari
- Pedodontics and Preventive Dentistry, Centre for Dental Education and Research, All India Institute of Medical Sciences, 6th Floor, New Delhi 110029, India
| | - Ritu Duggal
- Orthodontics and Dentofacial Deformities, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi 110029, India
| | - Anoop Chawla
- Department of Mechanical Engineering, Indian Institute of Technology, New Delhi 110016, India
| |
Collapse
|
7
|
Yang C, Weiss AS, Tarakanova A. Changes in elastin structure and extensibility induced by hypercalcemia and hyperglycemia. Acta Biomater 2022; 163:131-145. [PMID: 35364318 DOI: 10.1016/j.actbio.2022.03.041] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 03/17/2022] [Accepted: 03/24/2022] [Indexed: 12/15/2022]
Abstract
Elastin is a key elastomeric protein responsible for the elasticity of many organs, including heart, skin, and blood vessels. Due to its intrinsic long life and low turnover rate, damage in elastin induced by pathophysiological conditions, such as hypercalcemia and hyperglycemia, accumulates during biological aging and in aging-associated diseases, such as diabetes mellitus and atherosclerosis. Prior studies have shown that calcification induced by hypercalcemia deteriorates the function of aortic tissues. Glycation of elastin is triggered by hyperglycemia and associated with elastic tissue damage and loss of mechanical functions via the accumulation of advanced glycation end products. To evaluate the effects on elastin's structural conformations and elasticity by hypercalcemia and hyperglycemia at the molecular scale, we perform classical atomistic and steered molecular dynamics simulations on tropoelastin, the soluble precursor of elastin, under different conditions. We characterize the interaction sites of glucose and calcium and associated structural conformational changes. Additionally, we find that elevated levels of calcium ions and glucose hinder the extensibility of tropoelastin by rearranging structural domains and altering hydrogen bonding patterns, respectively. Overall, our investigation helps to reveal the behavior of tropoelastin and the biomechanics of elastin biomaterials in these physiological environments. STATEMENT OF SIGNIFICANCE: Elastin is a key component of elastic fibers which endow many important tissues and organs, from arteries and veins, to skin and heart, with strength and elasticity. During aging and aging-associated diseases, such as diabetes mellitus and atherosclerosis, physicochemical stressors, including hypercalcemia and hyperglycemia, induce accumulated irreversible damage in elastin, and consequently alter mechanical function. Yet, molecular mechanisms associated with these processes are still poorly understood. Here, we present the first study on how these changes in elastin structure and extensibility are induced by hypercalcemia and hyperglycemia at the molecular scale, revealing the essential roles that calcium and glucose play in triggering structural alterations and mechanical stiffness. Our findings yield critical insights into the first steps of hypercalcemia- and hyperglycemia-mediated aging.
Collapse
Affiliation(s)
- Chengeng Yang
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - Anthony S Weiss
- Charles Perkins Centre, The University of Sydney, Sydney, NSW, Australia; School of Life and Environmental Sciences, The University of Sydney, Sydney, NSW, Australia; Sydney Nano Institute, The University of Sydney, Sydney, NSW, Australia
| | - Anna Tarakanova
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA; Department of Mechanical Engineering, University of Connecticut, Storrs, CT, USA.
| |
Collapse
|
8
|
Boraldi F, Lofaro FD, Cossarizza A, Quaglino D. The "Elastic Perspective" of SARS-CoV-2 Infection and the Role of Intrinsic and Extrinsic Factors. Int J Mol Sci 2022; 23:ijms23031559. [PMID: 35163482 PMCID: PMC8835950 DOI: 10.3390/ijms23031559] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/20/2022] [Accepted: 01/28/2022] [Indexed: 02/07/2023] Open
Abstract
Elastin represents the structural component of the extracellular matrix providing elastic recoil to tissues such as skin, blood vessels and lungs. Elastogenic cells secrete soluble tropoelastin monomers into the extracellular space where these monomers associate with other matrix proteins (e.g., microfibrils and glycoproteins) and are crosslinked by lysyl oxidase to form insoluble fibres. Once elastic fibres are formed, they are very stable, highly resistant to degradation and have an almost negligible turnover. However, there are circumstances, mainly related to inflammatory conditions, where increased proteolytic degradation of elastic fibres may lead to consequences of major clinical relevance. In severely affected COVID-19 patients, for instance, the massive recruitment and activation of neutrophils is responsible for the profuse release of elastases and other proteolytic enzymes which cause the irreversible degradation of elastic fibres. Within the lungs, destruction of the elastic network may lead to the permanent impairment of pulmonary function, thus suggesting that elastases can be a promising target to preserve the elastic component in COVID-19 patients. Moreover, intrinsic and extrinsic factors additionally contributing to damaging the elastic component and to increasing the spread and severity of SARS-CoV-2 infection are reviewed.
Collapse
Affiliation(s)
- Federica Boraldi
- Department of Life Sciences, University of Modena and Reggio Emilia, 41125 Modena, Italy; (F.B.); (F.D.L.)
| | - Francesco Demetrio Lofaro
- Department of Life Sciences, University of Modena and Reggio Emilia, 41125 Modena, Italy; (F.B.); (F.D.L.)
| | - Andrea Cossarizza
- Department of Medical and Surgical Sciences for Children and Adults, University of Modena and Reggio Emilia, 41125 Modena, Italy;
| | - Daniela Quaglino
- Department of Life Sciences, University of Modena and Reggio Emilia, 41125 Modena, Italy; (F.B.); (F.D.L.)
- Correspondence:
| |
Collapse
|
9
|
Bianco G, Levy AM, Grytz R, Fazio MA. Effect of different preconditioning protocols on the viscoelastic inflation response of the posterior sclera. Acta Biomater 2021; 128:332-345. [PMID: 33932581 DOI: 10.1016/j.actbio.2021.04.042] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 04/18/2021] [Accepted: 04/20/2021] [Indexed: 12/11/2022]
Abstract
Preconditioning by repeated cyclic loads is routinely used in ex vivo mechanical testing of soft biological tissues. The goal of preconditioning is to achieve a steady and repeatable mechanical response and to measure material properties that are representative of the in vivo condition. Preconditioning protocols vary across studies, and their effect on the viscoelastic response of tested soft tissue is typically not reported or analyzed. We propose a methodology to systematically analyze the preconditioning process with application to inflation testing. We investigated the effect of preconditioning on the viscoelastic inflation response of tree shrew posterior sclera using two preconditioning protocols: (i) continuous cyclic loading-unloading without rest and (ii) cyclic loading-unloading with 15-min rest between cycles. Posterior scleral surface strain was measured using three-dimensional Digital Image Correlation (3D-DIC). We used five variables of characterizing features of the stress-strain loop curve to compare the two preconditioning protocols. Our results showed protocol-dependent differences in the tissue response during preconditioning and at the preconditioned state. Incorporating a resting time between preconditioning cycles significantly decreased the number of cycles (10.5 ± 2.9 cycles vs. 3.1 ± 0.5 cycles, p < 0.001) but increased the total time (15.8 ± 4.4 min vs. 51.2 ± 8.3 min, p < 0.001) needed to reach preconditioned state. At the preconditioned state, 2 of 5 characteristic variables differed significantly between protocols: hysteresis loop area (difference=0.023 kJ/m3, p = 0.0020) and elastic modulus at high IOPs (difference=24.0 MPa, p = 0.0238). Our results suggest that the analysis of the preconditioning process is an essential part of inflation experiments and a prerequisite to properly characterize the tissue viscoelastic response. Furthermore, material properties obtained at the preconditioned state can be impacted by the resting time used during preconditioning and may not be directly compared across studies if the resting time varies by 15 min between studies. STATEMENT OF SIGNIFICANCE: Although applying a preconditioning protocol by repeated cyclic loads is common practice in ex vivo mechanical characterization of soft tissues, the tissue response is typically not reported or analyzed, and the protocol's potential effect on the response remains unclear. This is partially caused by lack of a standardized methodology to precondition soft tissues. We present the first systematic analysis of two representative preconditioning protocols used during inflation testing in ocular biomechanics. Our results show protocol-dependent differences in the viscoelastic response during the preconditioning process and at the preconditioned state. Consequently, the analysis of the preconditioning response represents an essential part of mechanical testing and a prerequisite to properly characterize the tissue viscoelastic response. The effect of preconditioning on the preconditioned state response must be considered when comparing results across studies with different preconditioning protocols.
Collapse
|
10
|
Wang R, Yu X, Gkousioudi A, Zhang Y. Effect of Glycation on Interlamellar Bonding of Arterial Elastin. EXPERIMENTAL MECHANICS 2021; 61:81-94. [PMID: 33583947 PMCID: PMC7880226 DOI: 10.1007/s11340-020-00644-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Accepted: 07/21/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND Interlamellar bonding in the arterial wall is often compromised by cardiovascular diseases. However, several recent nationwide and hospital-based studies have uniformly reported reduced risk of thoracic aortic dissection in patients with diabetes. As one of the primary structural constituents in the arterial wall, elastin plays an important role in providing its interlamellar structural integrity. OBJECTIVE The purpose of this study is to examine the effects of glycation on the interlamellar bonding properties of arterial elastin. METHODS Purified elastin network was isolated from porcine descending thoracic aorta and incubated in 2 M glucose solution for 7, 14 or 21 days at 37 °C. Peeling and direct tension tests were performed to provide complimentary information on understanding the interlamellar layer separation properties of elastin network with glycation effect. Peeling tests were simulated using a cohesive zone model (CZM). Multiphoton imaging was used to visualize the interlamellar elastin fibers in samples subjected to peeling and direct tension. RESULTS Peeling and direct tension tests show that interlamellar energy release rate and strength both increases with the duration of glucose treatment. The traction at damage initiation estimated for the CZM agrees well with the interlamellar strength measurements from direct tension tests. Glycation was also found to increase the interlamellar failure strain of arterial elastin. Multiphoton imaging confirmed the contribution of radially running elastin fibers to resisting dissection. CONCLUSIONS Nonenzymatic glycation reduces the propensity of arterial elastin to dissection. This study also suggests that the CZM effectively describes the interlamellar bonding properties of arterial elastin.
Collapse
Affiliation(s)
- R Wang
- Department of Mechanical Engineering, Boston University, Boston, MA 02215
| | - X Yu
- Department of Mechanical Engineering, Boston University, Boston, MA 02215
| | - A Gkousioudi
- Department of Mechanical Engineering, Boston University, Boston, MA 02215
| | - Y Zhang
- Department of Mechanical Engineering, Boston University, Boston, MA 02215
- Department of Biomedical Engineering, Boston University, Boston, MA 02215
- Divison of Materials Science & Engineering, Boston University, Boston, MA 02215
| |
Collapse
|
11
|
Zwirner J, Scholze M, Ondruschka B, Hammer N. What is Considered a Variation of Biomechanical Parameters in Tensile Tests of Collagen-Rich Human Soft Tissues? - Critical Considerations Using the Human Cranial Dura Mater as a Representative Morpho-Mechanic Model. MEDICINA (KAUNAS, LITHUANIA) 2020; 56:E520. [PMID: 33027931 PMCID: PMC7600870 DOI: 10.3390/medicina56100520] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 09/27/2020] [Accepted: 09/28/2020] [Indexed: 12/23/2022]
Abstract
Background and Objectives: Profound knowledge on the load-dependent behavior of human soft tissues is required for the development of suitable replacements as well as for realistic computer simulations. Regarding the former, e.g., the anisotropy of a particular biological tissue has to be represented with site- and direction-dependent particular mechanical values. Contrary to this concept of consistent mechanical properties of a defined soft tissue, mechanical parameters of soft tissues scatter considerably when being determined in tensile tests. In spite of numerous measures taken to standardize the mechanical testing of soft tissues, several setup- and tissue-related factors remain to influence the mechanical parameters of human soft tissues to a yet unknown extent. It is to date unclear if measurement extremes should be considered a variation or whether these data have to be deemed incorrect measurement outliers. This given study aimed to determine mechanical parameters of the human cranial dura mater as a model for human soft tissues using a highly standardized protocol and based on this, critically evaluate the definition for the term mechanical "variation" of human soft tissue. Materials and Methods: A total of 124 human dura mater samples with an age range of 3 weeks to 94 years were uniformly retrieved, osmotically adapted and mechanically tested using customized 3D-printed equipment in a quasi-static tensile testing setup. Scanning electron microscopy of 14 samples was conducted to relate the mechanical parameters to morphological features of the dura mater. Results: The here obtained mechanical parameters were scattered (elastic modulus = 46.06 MPa, interquartile range = 33.78 MPa; ultimate tensile strength = 5.56 MPa, interquartile range = 4.09 MPa; strain at maximum force = 16.58%, interquartile range = 4.81%). Scanning electron microscopy revealed a multi-layered nature of the dura mater with varying fiber directions between its outer and inner surface. Conclusions: It is concluded that mechanical parameters of soft tissues such as human dura mater are highly variable even if a highly standardized testing setup is involved. The tissue structure and composition appeared to be the main contributor to the scatter of the mechanical parameters. In consequence, mechanical variation of soft tissues can be defined as the extremes of a biomechanical parameter due to an uncontrollable change in tissue structure and/or the respective testing setup.
Collapse
Affiliation(s)
- Johann Zwirner
- Department of Anatomy, University of Otago, Dunedin 9016, New Zealand
| | - Mario Scholze
- Institute of Materials Science and Engineering, Chemnitz University of Technology, 09125 Chemnitz, Germany;
- Department of Macroscopic and Clinical Anatomy, Medical University of Graz, 8010 Graz, Austria
| | - Benjamin Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, 22529 Hamburg, Germany;
| | - Niels Hammer
- Department of Macroscopic and Clinical Anatomy, Medical University of Graz, 8010 Graz, Austria
- Department of Orthopaedic and Trauma Surgery, University of Leipzig, 04103 Leipzig, Germany
- Fraunhofer IWU, 01187 Dresden, Germany
| |
Collapse
|
12
|
Myneni M, Rao A, Jiang M, Moreno MR, Rajagopal KR, Benjamin CC. Segmental Variations in the Peel Characteristics of the Porcine Thoracic Aorta. Ann Biomed Eng 2020; 48:1751-1767. [PMID: 32152801 DOI: 10.1007/s10439-020-02489-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 03/03/2020] [Indexed: 10/24/2022]
Abstract
Aortic dissection occurs predominantly in the thoracic aorta and the mechanisms for the initiation and propagation of the tear in aortic dissection are not well understood. We study the tearing characteristics of the porcine thoracic aorta using a peeling test and we estimate the peeling energy per unit area in the ascending and the descending segments. The stretch and the peel force per unit width undergone by the peeled halves of a rectangular specimen are measured. We find that there can be significant variation in the stretch within the specimen and the stretch between the markers in the specimen varies with the dynamics of peeling. We found that in our experiment the stretch achieved in the peeled halves was such that it was in the range of the stretch at which the stress-stretch curve for the uniaxial experiment starts deviating from linearity. Higher peeling energy per unit area is required in the ascending aorta compared to the descending aorta. Longitudinal specimens required higher peeling energy per unit area when compared to the circumferential specimens.
Collapse
Affiliation(s)
- Manoj Myneni
- Department of Mechanical Engineering, Texas A&M University, 100 Mechanical Engineering Office Building, College Station, TX, 77843-3123, USA
| | - Akshay Rao
- Department of Mechanical Engineering, Texas A&M University, 100 Mechanical Engineering Office Building, College Station, TX, 77843-3123, USA
| | - Mingliang Jiang
- Department of Mechanical Engineering, Texas A&M University, 100 Mechanical Engineering Office Building, College Station, TX, 77843-3123, USA
| | - Michael R Moreno
- Department of Mechanical Engineering, Texas A&M University, 100 Mechanical Engineering Office Building, College Station, TX, 77843-3123, USA
| | - K R Rajagopal
- Department of Mechanical Engineering, Texas A&M University, 100 Mechanical Engineering Office Building, College Station, TX, 77843-3123, USA
| | - Chandler C Benjamin
- Department of Mechanical Engineering, Texas A&M University, 100 Mechanical Engineering Office Building, College Station, TX, 77843-3123, USA.
| |
Collapse
|
13
|
Characterization of chemoelastic effects in arteries using digital volume correlation and optical coherence tomography. Acta Biomater 2020; 102:127-137. [PMID: 31794873 DOI: 10.1016/j.actbio.2019.11.049] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 11/25/2019] [Accepted: 11/26/2019] [Indexed: 12/13/2022]
Abstract
Understanding stress-strain relationships in arteries is important for fundamental investigations in mechanobiology. Here we demonstrate the essential role of chemoelasticity in determining the mechanical properties of arterial tissues. Stepwise stress-relaxation uniaxial tensile tests were carried out on samples of porcine thoracic aortas immersed in a hyperosmotic solution. The tissue deformations were tracked using optical coherence tomography (OCT) during the tensile tests and digital volume correlation (DVC) was used to obtain measurements of depth-resolved strains across the whole thickness of the tested aortas. The hyperosmotic solution exacerbated chemoelastic effects, and we were able to measure different manifestations of these chemoelastic effects: swelling of the media inducing a modification of its optical properties, and existence of a transverse tensile strain. For the first time ever to our best knowledge, 3D strains induced by chemoelastic effects in soft tissues were quantified thanks to the OCT-DVC method. Without doubt, chemoelasticity plays an essential role in arterial mechanobiology in vivo and future work should focus on characterizing chemoelastic effects in arterial walls under physiological and disease conditions. STATEMENT OF SIGNIFICANCE: Chemoelasticity, coupling osmotic phenomena and mechanical stresses, is essential in soft tissue mechanobiology. For the first time ever, we measure and analyze 3D strain fields induced by these chemoelastic effects thanks to the unique combination of OCT imaging and digital volume correlation.
Collapse
|
14
|
The status and challenges of replicating the mechanical properties of connective tissues using additive manufacturing. J Mech Behav Biomed Mater 2019; 103:103544. [PMID: 32090944 DOI: 10.1016/j.jmbbm.2019.103544] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Revised: 10/29/2019] [Accepted: 11/16/2019] [Indexed: 01/23/2023]
Abstract
The ability to fabricate complex structures via precise and heterogeneous deposition of biomaterials makes additive manufacturing (AM) a leading technology in the creation of implants and tissue engineered scaffolds. Connective tissues (CTs) remain attractive targets for manufacturing due to their "simple" tissue compositions that, in theory, are replicable through choice of biomaterial(s) and implant microarchitecture. Nevertheless, characterisation of the mechanical and biological functions of 3D printed constructs with respect to their host tissues is often limited and remains a restriction towards their translation into clinical practice. This review aims to provide an update on the current status of AM to mimic the mechanical properties of CTs, with focus on arterial tissue, articular cartilage and bone, from the perspective of printing platforms, biomaterial properties, and topological design. Furthermore, the grand challenges associated with the AM of CT replacements and their subsequent regulatory requirements are discussed to aid further development of reliable and effective implants.
Collapse
|
15
|
Barocas VH, Winkelstein BA. Editors' Choice Papers for 2018. J Biomech Eng 2019; 141:2728069. [PMID: 30840049 DOI: 10.1115/1.4043072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2018] [Indexed: 02/28/2024]
Abstract
No abstract.
Collapse
Affiliation(s)
- Victor H Barocas
- 7-105 Nils Hasselmo Hall 312 Church Street SE Minneapolis, MN 55455
| | | |
Collapse
|
16
|
James BD, Allen JB. Vascular Endothelial Cell Behavior in Complex Mechanical Microenvironments. ACS Biomater Sci Eng 2018; 4:3818-3842. [PMID: 33429612 DOI: 10.1021/acsbiomaterials.8b00628] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The vascular mechanical microenvironment consists of a mixture of spatially and temporally changing mechanical forces. This exposes vascular endothelial cells to both hemodynamic forces (fluid flow, cyclic stretching, lateral pressure) and vessel forces (basement membrane mechanical and topographical properties). The vascular mechanical microenvironment is "complex" because these forces are dynamic and interrelated. Endothelial cells sense these forces through mechanosensory structures and transduce them into functional responses via mechanotransduction pathways, culminating in behavior directly affecting vascular health. Recent in vitro studies have shown that endothelial cells respond in nuanced and unique ways to combinations of hemodynamic and vessel forces as compared to any single mechanical force. Understanding the interactive effects of the complex mechanical microenvironment on vascular endothelial behavior offers the opportunity to design future biomaterials and biomedical devices from the bottom-up by engineering for the cellular response. This review describes and defines (1) the blood vessel structure, (2) the complex mechanical microenvironment of the vascular endothelium, (3) the process in which vascular endothelial cells sense mechanical forces, and (4) the effect of mechanical forces on vascular endothelial cells with specific attention to recent works investigating the influence of combinations of mechanical forces. We conclude this review by providing our perspective on how the field can move forward to elucidate the effects of the complex mechanical microenvironment on vascular endothelial cell behavior.
Collapse
Affiliation(s)
- Bryan D James
- Department of Materials Science & Engineering, University of Florida, 100 Rhines Hall, PO Box 116400, Gainesville, Florida 32611, United States.,Institute for Computational Engineering, University of Florida, 300 Weil Hall, PO Box 116550, Gainesville, Florida 32611, United States
| | - Josephine B Allen
- Department of Materials Science & Engineering, University of Florida, 100 Rhines Hall, PO Box 116400, Gainesville, Florida 32611, United States.,Institute for Cell and Tissue Science and Engineering, 300 Weil Hall, PO Box 116550, Gainesville, Florida 32611, United States
| |
Collapse
|