1
|
Kotelsky A, Carrier JS, Buckley MR. Quantification of Cartilage Poroelastic Material Properties Via Analysis of Loading-Induced Cell Death. J Biomech Eng 2024; 146:081006. [PMID: 38530647 PMCID: PMC11080949 DOI: 10.1115/1.4065194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 03/20/2024] [Accepted: 03/21/2024] [Indexed: 03/28/2024]
Abstract
Articular cartilage (AC) is a load-bearing tissue that covers long bones in synovial joints. The biphasic/poroelastic mechanical properties of AC help it to protect joints by distributing loads, absorbing impact forces, and reducing friction. Unfortunately, alterations in these mechanical properties adversely impact cartilage function and precede joint degeneration in the form of osteoarthritis (OA). Thus, understanding what factors regulate the poroelastic mechanical properties of cartilage is of great scientific and clinical interest. Transgenic mouse models provide a valuable platform to delineate how specific genes contribute to cartilage mechanical properties. However, the poroelastic mechanical properties of murine articular cartilage are challenging to measure due to its small size (thickness ∼ 50 microns). In the current study, our objective was to test whether the poroelastic mechanical properties of murine articular cartilage can be determined based solely on time-dependent cell death measurements under constant loading conditions. We hypothesized that in murine articular cartilage subjected to constant, sub-impact loading from an incongruent surface, cell death area and tissue strain are closely correlated. We further hypothesized that the relationship between cell death area and tissue strain can be used-in combination with inverse finite element modeling-to compute poroelastic mechanical properties. To test these hypotheses, murine cartilage-on-bone explants from different anatomical locations were subjected to constant loading conditions by an incongruent surface in a custom device. Cell death area increased over time and scaled linearly with strain, which rose in magnitude over time due to poroelastic creep. Thus, we were able to infer tissue strain from cell death area measurements. Moreover, using tissue strain values inferred from cell death area measurements, we applied an inverse finite element modeling procedure to compute poroelastic material properties and acquired data consistent with previous studies. Collectively, our findings demonstrate in the key role poroelastic creep plays in mediating cell survival in mechanically loaded cartilage and verify that cell death area can be used as a surrogate measure of tissue strain that enables determination of murine cartilage mechanical properties.
Collapse
Affiliation(s)
- Alexander Kotelsky
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627
| | - Joseph S. Carrier
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627
- University of Rochester
| | - Mark R. Buckley
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627
| |
Collapse
|
2
|
Ead M, Wu K, Jar C, Duke K, Jomha N, Westover L. Mechanical Properties of Fresh, Frozen and Vitrified Articular Cartilage. Ann Biomed Eng 2023; 51:2001-2012. [PMID: 37129781 DOI: 10.1007/s10439-023-03220-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 04/21/2023] [Indexed: 05/03/2023]
Abstract
Osteochondral allograft transplantations are typically used to treat focal articular cartilage injuries where the damaged cartilage is replaced with fresh cadaveric donor grafts. Despite the notable success rate of this procedure, it is limited by fresh donor tissue availability which can only be stored for approximately 28 days after harvest. Vitrification, a form of cryopreservation, can extend the storage time of cartilage. Although it has shown to preserve chondrocyte viability, its effect on the mechanical properties of the tissue has not been thoroughly investigated. Therefore, in this study, the mechanical properties of fresh, frozen, and vitrified articular cartilage were evaluated through unconfined compression testing. Results showed that the peak modulus, equilibrium modulus, and relaxation time constants of the vitrified and control samples (tested one day after harvest) were similar and higher than the fresh (tested 21 days after harvest) and frozen samples. This demonstrated that vitrification does not adversely affect the mechanical properties of cartilage and can be used as an alternative to fresh allografts which are limited by storage time. The fresh samples also had inferior mechanical properties compared to the control samples suggesting that vitrified allografts could potentially improve clinical outcomes in addition to increasing donor tissue availability.
Collapse
Affiliation(s)
- Maha Ead
- Department of Mechanical Engineering, University of Alberta, Edmonton, Canada.
| | - Kezhou Wu
- Department of Surgery, University of Alberta, Edmonton, Canada
- Sports Medicine Center, The First Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Chester Jar
- Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
| | - Kajsa Duke
- Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
| | - Nadr Jomha
- Department of Surgery, University of Alberta, Edmonton, Canada
| | - Lindsey Westover
- Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
| |
Collapse
|
3
|
Belluzzi E, Todros S, Pozzuoli A, Ruggieri P, Carniel EL, Berardo A. Human Cartilage Biomechanics: Experimental and Theoretical Approaches towards the Identification of Mechanical Properties in Healthy and Osteoarthritic Conditions. Processes (Basel) 2023. [DOI: 10.3390/pr11041014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023] Open
Abstract
Articular cartilage is a complex connective tissue with the fundamental functions of load bearing, shock absorption and lubrication in joints. However, traumatic events, aging and degenerative pathologies may affect its structural integrity and function, causing pain and long-term disability. Osteoarthritis represents a health issue, which concerns an increasing number of people worldwide. Moreover, it has been observed that this pathology also affects the mechanical behavior of the articular cartilage. To better understand this correlation, the here proposed review analyzes the physiological aspects that influence cartilage microstructure and biomechanics, with a special focus on the pathological changes caused by osteoarthritis. Particularly, the experimental data on human articular cartilage are presented with reference to different techniques adopted for mechanical testing and the related theoretical mechanical models usually applied to articular cartilage are briefly discussed.
Collapse
|
4
|
Petitjean N, Canadas P, Royer P, Noël D, Le Floc'h S. Cartilage biomechanics: From the basic facts to the challenges of tissue engineering. J Biomed Mater Res A 2022; 111:1067-1089. [PMID: 36583681 DOI: 10.1002/jbm.a.37478] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 11/07/2022] [Accepted: 11/22/2022] [Indexed: 12/31/2022]
Abstract
Articular cartilage (AC) is the thin tissue that covers the long bone ends in the joints and that ensures the transmission of forces between adjacent bones while allowing nearly frictionless movements between them. AC repair is a technologic and scientific challenge that has been addressed with numerous approaches. A major deadlock is the capacity to take in account its complex mechanical properties in repair strategies. In this review, we first describe the major mechanical behaviors of AC for the non-specialists. Then, we show how researchers have progressively identified specific mechanical parameters using mathematical models. There are still gaps in our understanding of some of the observations concerning AC biomechanical properties, particularly the differences in extracellular matrix stiffness measured at the microscale and at the millimetric scale. Nevertheless, for bioengineering applications, AC repair strategies must take into account what are commonly considered the main mechanical features of cartilage: its ability to withstand high stresses through three main behaviors (elasticity, poroelasticity and swelling). Finally, we emphasize that future studies need to investigate AC mechanical properties at different scales, particularly the gradient of mechanical properties around cells and across the cartilage depth, and the differences in mechanical properties at different scales. This multi-scale approach could greatly enhance the success of AC restorative approaches.
Collapse
Affiliation(s)
| | | | - Pascale Royer
- LMGC, University of Montpellier, CNRS, Montpellier, France
| | - Danièle Noël
- IRMB, University of Montpellier, INSERM, Montpellier, France.,Clinical Immunology and Osteoarticular Disease Therapeutic Unit, Department of Rheumatology, CHU Montpellier, France
| | | |
Collapse
|
5
|
Orozco GA, Tanska P, Gustafsson A, Korhonen RK, Isaksson H. Crack propagation in articular cartilage under cyclic loading using cohesive finite element modeling. J Mech Behav Biomed Mater 2022; 131:105227. [DOI: 10.1016/j.jmbbm.2022.105227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 03/01/2022] [Accepted: 04/02/2022] [Indexed: 11/28/2022]
|
6
|
Mohammadi A, te Moller NCR, Ebrahimi M, Plomp S, Brommer H, van Weeren PR, Mäkelä JTA, Töyräs J, Korhonen RK. Site- and Zone-Dependent Changes in Proteoglycan Content and Biomechanical Properties of Bluntly and Sharply Grooved Equine Articular Cartilage. Ann Biomed Eng 2022; 50:1787-1797. [PMID: 35754073 PMCID: PMC9794534 DOI: 10.1007/s10439-022-02991-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 06/09/2022] [Indexed: 12/31/2022]
Abstract
In this study, we mapped and quantified changes of proteoglycan (PG) content and biomechanical properties in articular cartilage in which either blunt or sharp grooves had been made, both close to the groove and more remote of it, and at the opposing joint surface (kissing site) in equine carpal joints. In nine adult Shetland ponies, standardized blunt and sharp grooves were surgically made in the radiocarpal and middle carpal joints of a randomly chosen front limb. The contralateral control limb was sham-operated. At 39 weeks after surgery, ponies were euthanized. In 10 regions of interest (ROIs) (six remote from the grooves and four directly around the grooves), PG content as a function of tissue-depth and distance-to-groove was estimated using digital densitometry. Biomechanical properties of the cartilage were evaluated in the six ROIs remote from the grooves. Compared to control joints, whole tissue depth PG loss was found in sites adjacent to sharp and, to a larger extent, blunt grooves. Also, superficial PG loss of the surgically untouched kissing cartilage layers was observed. Significant PG loss was observed up to 300 µm (sharp) and at 500 µm (blunt) from the groove into the surrounding tissue. Equilibrium modulus was lower in grooved cartilage than in controls. Grooves, in particular blunt grooves, gave rise to severe PG loss close to the grooved sites and to mild degeneration more remote from the grooves in both sharply and bluntly grooved cartilage and at the kissing sites, resulting in loss of mechanical strength over the 9-month period.
Collapse
Affiliation(s)
- Ali Mohammadi
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Nikae C. R. te Moller
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands
| | - Mohammadhossein Ebrahimi
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland ,Research Unit of Medical Imaging, Physics and Technology, Faculty of Medicine, University of Oulu, Oulu, Finland
| | - Saskia Plomp
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands
| | - Harold Brommer
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands
| | - P. René van Weeren
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands
| | - Janne T. A. Mäkelä
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Juha Töyräs
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland ,School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia ,Science Service Center, Kuopio University Hospital, Kuopio, Finland
| | - Rami K. Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
7
|
Human adipose-derived stromal/stem cells expressing doublecortin improve cartilage repair in rabbits and monkeys. NPJ Regen Med 2021; 6:82. [PMID: 34848747 PMCID: PMC8633050 DOI: 10.1038/s41536-021-00192-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 10/29/2021] [Indexed: 11/25/2022] Open
Abstract
Localized cartilage lesions in early osteoarthritis and acute joint injuries are usually treated surgically to restore function and relieve pain. However, a persistent clinical challenge remains in how to repair the cartilage lesions. We expressed doublecortin (DCX) in human adipose-derived stromal/stem cells (hASCs) and engineered hASCs into cartilage tissues using an in vitro 96-well pellet culture system. The cartilage tissue constructs with and without DCX expression were implanted in the knee cartilage defects of rabbits (n = 42) and monkeys (n = 12). Cohorts of animals were euthanized at 6, 12, and 24 months after surgery to evaluate the cartilage repair outcomes. We found that DCX expression in hASCs increased expression of growth differentiation factor 5 (GDF5) and matrilin 2 in the engineered cartilage tissues. The cartilage tissues with DCX expression significantly enhanced cartilage repair as assessed macroscopically and histologically at 6, 12, and 24 months after implantation in the rabbits and 24 months after implantation in the monkeys, compared to the cartilage tissues without DCX expression. These findings suggest that hASCs expressing DCX may be engineered into cartilage tissues that can be used to treat localized cartilage lesions.
Collapse
|
8
|
Chawla D, Han G, Eriten M, Henak CR. Microindentation Technique to Create Localized Cartilage Microfractures. Curr Protoc 2021; 1:e280. [PMID: 34670019 DOI: 10.1002/cpz1.280] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Articular cartilage is a multiphasic, anisotropic, and heterogeneous material. Although cartilage possesses excellent mechanical and biological properties, it can undergo mechanical damage, resulting in osteoarthritis. Thus, it is important to understand the microscale failure behavior of cartilage in both basic science and clinical contexts. Determining cartilage failure behavior and mechanisms provides insight for improving treatment strategies to delay osteoarthritis initiation or progression and can also enhance the value of cartilage as bioinspiration for material fabrication. To investigate microscale failure behavior, we developed a protocol to initiate fractures by applying a microindentation technique using a well-defined tip geometry that creates localized cracks across a range of loading rates. The protocol includes extracting the tissue from the joint, preparing samples, and microfracture. Various aspects of the experiment, such as loading profile and solvent, can be adjusted to mimic physiological or pathological conditions and thereby further clarify phenomena underlying articular cartilage failure. © 2021 Wiley Periodicals LLC. Basic Protocol 1: Harvesting and dissection of the joint surfaces Basic Protocol 2: Preparation of samples for microindentation and fatigue testing Basic Protocol 3: Microfracture using microindentation Basic Protocol 4: Crack propagation under cyclic loading.
Collapse
Affiliation(s)
- Dipul Chawla
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Guebum Han
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota, USA
| | - Melih Eriten
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Corinne R Henak
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
9
|
Nissinen MT, Hänninen N, Prakash M, Mäkelä JTA, Nissi MJ, Töyräs J, Nieminen MT, Korhonen RK, Tanska P. Functional and structural properties of human patellar articular cartilage in osteoarthritis. J Biomech 2021; 126:110634. [PMID: 34454206 DOI: 10.1016/j.jbiomech.2021.110634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 06/18/2021] [Accepted: 07/05/2021] [Indexed: 10/20/2022]
Abstract
Changes in the fibril-reinforced poroelastic (FRPE) mechanical material parameters of human patellar cartilage at different stages of osteoarthritis (OA) are not known. Further, the patellofemoral joint loading is thought to include more sliding and shear compared to other knee joint locations, thus, the relations between structural and functional changes may differ in OA. Thus, our aim was to determine the patellar cartilage FRPE properties followed by associating them with the structure and composition. Osteochondral plugs (n = 14) were harvested from the patellae of six cadavers. Then, the FRPE material properties were determined, and those properties were associated with proteoglycan content, collagen fibril orientation angle, optical retardation (fibril parallelism), and the state of OA of the samples. The initial fibril network modulus and permeability strain-dependency factor were 72% and 63% smaller in advanced OA samples when compared to early OA samples. Further, we observed a negative association between the initial fibril network modulus and optical retardation (r = -0.537, p < 0.05). We also observed positive associations between 1) the initial permeability and optical retardation (r = 0.547, p < 0.05), and 2) the initial fibril network modulus and optical density (r = 0.670, p < 0.01).These results suggest that the reduced pretension of the collagen fibrils, as shown by the reduced initial fibril network modulus, is linked with the loss of proteoglycans and cartilage swelling in human patellofemoral OA. The characterization of these changes is important to improve the representativeness of knee joint models in tissue and cell scale.
Collapse
Affiliation(s)
- Mikko T Nissinen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland; Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland.
| | - Nina Hänninen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland; Research Unit of Medical Imaging, Physics, and Technology, University of Oulu, Oulu, Finland
| | - Mithilesh Prakash
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Janne T A Mäkelä
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Mikko J Nissi
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland; Research Unit of Medical Imaging, Physics, and Technology, University of Oulu, Oulu, Finland
| | - Juha Töyräs
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland; Science Service Center, Kuopio University Hospital, Kuopio, Finland; School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia
| | - Miika T Nieminen
- Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland; Research Unit of Medical Imaging, Physics, and Technology, University of Oulu, Oulu, Finland; Department of Diagnostic Radiology, Oulu University Hospital, Oulu, Finland
| | - Rami K Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Petri Tanska
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
10
|
Elastic, Dynamic Viscoelastic and Model-Derived Fibril-Reinforced Poroelastic Mechanical Properties of Normal and Osteoarthritic Human Femoral Condyle Cartilage. Ann Biomed Eng 2021; 49:2622-2634. [PMID: 34341898 PMCID: PMC8455392 DOI: 10.1007/s10439-021-02838-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 07/15/2021] [Indexed: 12/27/2022]
Abstract
Osteoarthritis (OA) degrades articular cartilage and weakens its function. Modern fibril-reinforced poroelastic (FRPE) computational models can distinguish the mechanical properties of main cartilage constituents, namely collagen, proteoglycans, and fluid, thus, they can precisely characterize the complex mechanical behavior of the tissue. However, these properties are not known for human femoral condyle cartilage. Therefore, we aimed to characterize them from human subjects undergoing knee replacement and from deceased donors without known OA. Multi-step stress-relaxation measurements coupled with sample-specific finite element analyses were conducted to obtain the FRPE material properties. Samples were graded using OARSI scoring to determine the severity of histopathological cartilage degradation. The results suggest that alterations in the FRPE properties are not evident in the moderate stages of cartilage degradation (OARSI 2-3) as compared with normal tissue (OARSI 0-1). Drastic deterioration of the FRPE properties was observed in severely degraded cartilage (OARSI 4). We also found that the FRPE properties of femoral condyle cartilage related to the collagen network (initial fibril-network modulus) and proteoglycan matrix (non-fibrillar matrix modulus) were greater compared to tibial and patellar cartilage in OA. These findings may inform cartilage tissue-engineering efforts and help to improve the accuracy of cartilage representations in computational knee joint models.
Collapse
|
11
|
Ristaniemi A, Tanska P, Stenroth L, Finnilä MAJ, Korhonen RK. Comparison of material models for anterior cruciate ligament in tension: from poroelastic to a novel fibril-reinforced nonlinear composite model. J Biomech 2020; 114:110141. [PMID: 33302181 DOI: 10.1016/j.jbiomech.2020.110141] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 11/05/2020] [Accepted: 11/12/2020] [Indexed: 12/15/2022]
Abstract
Computational models of the knee joint are useful for evaluating stresses and strains within the joint tissues. However, the outcome of those models is sensitive to the material model and material properties chosen for ligaments, the collagen reinforced tissues connecting bone to bone. The purpose of this study was to investigate different compositionally motivated material models and further to develop a model that can accurately reproduce experimentally measured stress-relaxation data of bovine anterior cruciate ligament (ACL). Tensile testing samples were extracted from ACLs of bovine knee joints (N = 10) and subjected to a three-step stress-relaxation test at the toe region. Data from the experiments was averaged and one average finite element model was generated to replicate the experiment. Poroelastic and different fibril-reinforced poro(visco)elastic material models were applied, and their material parameters were optimized to reproduce the experimental force-time response. Material models with only fluid flow mediated relaxation were not able to capture the stress-relaxation behavior (R2 = 0.806, 0.803 and 0.938). The inclusion of the viscoelasticity of the fibrillar network improved the model prediction (R2 = 0.978 and 0.976), but the complex stress-relaxation behavior was best captured by a poroelastic model with a nonlinear two-relaxation-time strain-recruited viscoelastic fibrillar network (R2 = 0.997). The results suggest that in order to replicate the multi-step stress-relaxation behavior of ACL in tension, the fibrillar network formulation should include the complex nonlinear viscoelastic phenomena.
Collapse
Affiliation(s)
- A Ristaniemi
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.
| | - P Tanska
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - L Stenroth
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - M A J Finnilä
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland
| | - R K Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
12
|
Fazaeli S, Ghazanfari S, Mirahmadi F, Everts V, Smit TH, Koolstra JH. The dynamic mechanical viscoelastic properties of the temporomandibular joint disc: The role of collagen and elastin fibers from a perspective of polymer dynamics. J Mech Behav Biomed Mater 2019; 100:103406. [PMID: 31473438 DOI: 10.1016/j.jmbbm.2019.103406] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Revised: 07/27/2019] [Accepted: 08/24/2019] [Indexed: 10/26/2022]
Abstract
The temporomandibular joint disc is a structure, characterized as heterogeneous fibrocartilage, and is composed of macromolecular biopolymers. Despite a large body of characterization studies, the contribution of matrix biopolymers on the dynamic viscoelastic behavior of the disc is poorly understood. Given the high permeability and low concentration of glycosaminoglycans in the disc, it has been suggested that poro-elastic behavior can be neglected and that the intrinsic viscoelastic nature of solid matrix plays a dominant role in governing its time-dependent behavior. This study attempts to quantify the contribution of collagen and elastin fibers to the viscoelastic properties of the disc. Using collagenase and elastase, we perturbed the collagen and elastin fibrillar network in porcine temporomandibular joint discs and investigated the changes of dynamic viscoelastic properties in five different regions of the disc. Following both treatments, the storage and loss moduli of these regions were reduced dramatically up to the point that the tissue was no longer mechanically heterogeneous. However, the proportion of changes in storage and loss moduli were different for each treatment, reflected in the decrease and increase of the loss tangent for collagenase and elastase treated discs, respectively. The reduction of storage and loss moduli of the disc correlated with a decrease of biopolymer length. The present study indicates that the compositional and structural changes of collagen and elastin fibers alter the viscoelastic properties of the disc consistent with polymer dynamics.
Collapse
Affiliation(s)
- Sepanta Fazaeli
- Department of Oral Cell Biology and Functional Anatomy, Academic Centre for Dentistry Amsterdam, University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.
| | - Samaneh Ghazanfari
- Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Geleen, the Netherlands; Department of Biohybrid & Medical Textiles (Biotex), RWTH Aachen University, Aachen, Germany.
| | - Fereshteh Mirahmadi
- Department of Oral Cell Biology and Functional Anatomy, Academic Centre for Dentistry Amsterdam, University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.
| | - Vincent Everts
- Department of Oral Cell Biology and Functional Anatomy, Academic Centre for Dentistry Amsterdam, University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.
| | - Theodoor Henri Smit
- Department of Medical Biology - Academic Medical Center Amsterdam, Amsterdam, the Netherlands.
| | - Jan Harm Koolstra
- Department of Oral Cell Biology and Functional Anatomy, Academic Centre for Dentistry Amsterdam, University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.
| |
Collapse
|
13
|
Molecular transport in articular cartilage - what have we learned from the past 50 years? Nat Rev Rheumatol 2019; 14:393-403. [PMID: 29899547 DOI: 10.1038/s41584-018-0033-5] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Developing therapeutic molecules that target chondrocytes and locally produced inflammatory factors within arthritic cartilage is an active area of investigation. The extensive studies that have been conducted over the past 50 years have enabled the accurate prediction and reliable optimization of the transport of a wide variety of molecules into cartilage. In this Review, the factors that can be used to tune the transport kinetics of therapeutics are summarized. Overall, the most crucial factor when designing new therapeutic molecules is solute size. The diffusivity and partition coefficient of a solute both decrease with increasing solute size as indicated by molecular mass or by hydrodynamic radius. Surprisingly, despite having an effective pore size of ~6 nm, molecules of ~16 nm radius can diffuse through the cartilage matrix. Alteration of the shape or charge of a solute and the application of physiological loading to cartilage can be used to predictably improve solute transport kinetics, and this knowledge can be used to improve the development of therapeutic agents for osteoarthritis that target the cartilage.
Collapse
|
14
|
Ravanfar M, Yao G. Simultaneous tractography and elastography imaging of the zone-specific structural and mechanical responses in articular cartilage under compressive loading. BIOMEDICAL OPTICS EXPRESS 2019; 10:3241-3256. [PMID: 31467777 PMCID: PMC6706024 DOI: 10.1364/boe.10.003241] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Revised: 05/28/2019] [Accepted: 05/29/2019] [Indexed: 05/09/2023]
Abstract
We quantified the precise zonal cartilage structural and mechanical responses to unconfined compressive loading by using simultaneous PSOCT based optical tractography and elastography imaging. Twelve bovine knee articular cartilage samples from six animals were imaged under bulk compression from 4% to 20%. The results revealed strong evidence that the conventional radial zone could be divided into two sub-zones with distinct mechanical properties. The "upper" part of the radial zone played a critical role in "absorbing" the mechanical compression. The study also showed that the zonal fiber organization greatly affected the cartilage structural and mechanical responses. A strong correlation was observed between the optical birefringence and logarithm of the Young's modulus. These new results provide useful information for improving mechanical modeling of articular cartilage and developing better cartilage-mimetic biomaterials.
Collapse
|
15
|
Danso EK, Julkunen P, Korhonen RK. Poisson's ratio of bovine meniscus determined combining unconfined and confined compression. J Biomech 2018; 77:233-237. [PMID: 30055840 DOI: 10.1016/j.jbiomech.2018.07.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Revised: 07/02/2018] [Accepted: 07/04/2018] [Indexed: 11/18/2022]
Abstract
Poisson's ratio has not been experimentally measured earlier for meniscus in compression. It is however an important intrinsic material property needed in biomechanical analysis and computational models. In this study, equilibrium Poisson's ratio of bovine meniscus (n = 6) was determined experimentally by combining stress-relaxation measurements in unconfined and confined compression geometries. The average Young's modulus, aggregate modulus and Poisson's ratio were 0.182 ± 0.086 MPa, 0.252 ± 0.089 MPa and 0.316 ± 0.040, respectively. These moduli are consistent with previously determined values, but the Poisson's ratio is higher than determined earlier for meniscus in compression through biomechanical modelling analysis. This new experimentally determined Poisson's ratio value could be used in the analysis of biomechanical data as well as in computational finite element analysis when the Poisson's ratio is needed as an input for the analysis.
Collapse
Affiliation(s)
- E K Danso
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA; Department of Applied Physics, University of Eastern Finland, POB 1627, FI-70211 Kuopio, Finland.
| | - P Julkunen
- Department of Applied Physics, University of Eastern Finland, POB 1627, FI-70211 Kuopio, Finland; Department of Clinical Neurophysiology, Kuopio University Hospital, POB 100, FI-70029, KYS, Kuopio, Finland
| | - R K Korhonen
- Department of Applied Physics, University of Eastern Finland, POB 1627, FI-70211 Kuopio, Finland
| |
Collapse
|
16
|
DiDomenico CD, Xiang Wang Z, Bonassar LJ. Cyclic Mechanical Loading Enhances Transport of Antibodies Into Articular Cartilage. J Biomech Eng 2017; 139:2588207. [PMID: 27893039 DOI: 10.1115/1.4035265] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2016] [Indexed: 11/08/2022]
Abstract
The goal of this study was to characterize antibody penetration through cartilage tissue under mechanical loading. Mechanical stimulation aids in the penetration of some proteins, but this effect has not characterized molecules such as antibodies (>100 kDa), which may hold some clinical value for treating osteoarthritis (OA). For each experiment, fresh articular cartilage plugs were obtained and exposed to fluorescently labeled antibodies while under cyclic mechanical load in unconfined compression for several hours. Penetration of these antibodies was quantified using confocal microscopy, and finite element (FE) simulations were conducted to predict fluid flow patterns within loaded samples. Transport enhancement followed a linear trend with strain amplitude (0.25-5%) and a nonlinear trend with frequency (0.25-2.60 Hz), with maximum enhancement found to be at 5% cyclic strain and 1 Hz, respectively. Regions of highest enhancement of transport within the tissue were associated with the regions of highest interstitial fluid velocity, as predicted from finite-element simulations. Overall, cyclic compression-enhanced antibody transport by twofold to threefold. To our knowledge, this is the first study to test how mechanical stimulation affects the diffusion of antibodies in cartilage and suggest further study into other important factors regarding macromolecular transport.
Collapse
Affiliation(s)
- Chris D DiDomenico
- Meinig School of Biomedical Engineering, Cornell University, 145 Weill Hall, Ithaca, NY 14853 e-mail:
| | - Zhen Xiang Wang
- Meinig School of Biomedical Engineering, Cornell University, 145 Weill Hall, Ithaca, NY 14853 e-mail:
| | - Lawrence J Bonassar
- Professor Meinig School of Biomedical Engineering, Sibley School of Mechanical and Aerospace Engineering, Cornell University, 149 Weill Hall, Ithaca, NY 14853 e-mail:
| |
Collapse
|
17
|
Finlay S, Seedhom BB, Carey DO, Bulpitt AJ, Treanor DE, Kirkham J. In Vitro Engineering of High Modulus Cartilage-Like Constructs. Tissue Eng Part C Methods 2016; 22:382-97. [PMID: 26850081 PMCID: PMC4827287 DOI: 10.1089/ten.tec.2015.0351] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
To date, the outcomes of cartilage repair have been inconsistent and have frequently yielded mechanically inferior fibrocartilage, thereby increasing the chances of damage recurrence. Implantation of constructs with biochemical composition and mechanical properties comparable to natural cartilage could be advantageous for long-term repair. This study attempted to create such constructs, in vitro, using tissue engineering principles. Bovine synoviocytes were seeded on nonwoven polyethylene terephthalate fiber scaffolds and cultured in chondrogenic medium for 4 weeks, after which uniaxial compressive loading was applied using an in-house bioreactor for 1 h per day, at a frequency of 1 Hz, for a further 84 days. The initial loading conditions, determined from the mechanical properties of the immature constructs after 4 weeks in chondrogenic culture, were strains ranging between 13% and 23%. After 56 days (sustained at 84 days) of loading, the constructs were stained homogenously with Alcian blue and for type-II collagen. Dynamic compressive moduli were comparable to the high end values for native cartilage and proportional to Alcian blue staining intensity. We suggest that these high moduli values were attributable to the bioreactor setup, which caused the loading regime to change as the constructs developed, that is, the applied stress and strain increased with construct thickness and stiffness, providing continued sufficient cell stimulation as further matrix was deposited. Constructs containing cartilage-like matrix with response to load similar to that of native cartilage could produce long-term effective cartilage repair when implanted.
Collapse
Affiliation(s)
- Scott Finlay
- 1 Division of Oral Biology, School of Dentistry, University of Leeds , Leeds, United Kingdom
| | - Bahaa B Seedhom
- 1 Division of Oral Biology, School of Dentistry, University of Leeds , Leeds, United Kingdom
| | - Duane O Carey
- 2 School of Computing, University of Leeds , Leeds, United Kingdom
| | - Andy J Bulpitt
- 2 School of Computing, University of Leeds , Leeds, United Kingdom
| | - Darren E Treanor
- 3 Department of Pathology, Leeds Institute of Cancer and Pathology, University of Leeds , Leeds, United Kingdom .,4 Leeds Teaching Hospitals NHS Trust , Leeds, United Kingdom
| | - Jennifer Kirkham
- 1 Division of Oral Biology, School of Dentistry, University of Leeds , Leeds, United Kingdom
| |
Collapse
|
18
|
Micromechanical model of biphasic biomaterials with internal adhesion: Application to nanocellulose hydrogel composites. Acta Biomater 2016; 29:149-160. [PMID: 26525114 DOI: 10.1016/j.actbio.2015.10.032] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2015] [Revised: 10/12/2015] [Accepted: 10/20/2015] [Indexed: 11/23/2022]
Abstract
The mechanical properties of hydrated biomaterials are non-recoverable upon unconfined compression if adhesion occurs between the structural components in the material upon fluid loss and apparent plastic behaviour. We explore these micromechanical phenomena by introducing an aggregation force and a critical yield pressure into the constitutive biphasic formulation for transversely isotropic tissues. The underlying hypothesis is that continual fluid pressure build-up during compression temporarily supresses aggregation. Once compression stops and the pressure falls below some critical value, internal aggregation occurs over a time scale comparable to the poroelastic time. We demonstrate this model by predicting the mechanical response of bacterial nanocellulose hydrogel composites, which are promising biomaterials and a structural mimetic for the plant cell wall. Cross-linking of cellulose by xyloglucan creates an extensional resistance and substantially increases the compressive modulus under large compression and densification. In comparison, incorporating non-crosslinking arabinoxylan into the hydrogel has little effect on its mechanics at the strain rates investigated. These results assist in elucidating the mechanical role of these polysaccharides in the complex plant cell wall structure. They also suggest xyloglucan is a suitable candidate to tailor the stiffness of nanocellulose hydrogels in biomaterial design, which includes modulating cell-adhesion in tissue engineering applications. The model and overall approach may be utilised to characterise and design a myriad of biomaterials and mammalian tissues, particularly those with a fibrillar structure. STATEMENT OF SIGNIFICANCE The mechanical properties of hydrated biomaterials can be non-recoverable upon compression due to increased adhesion occurring between the structural components in the material. Cellulose-hemicellulose composite hydrogels constitute a classical example of this phenomenon, since fibres can freely re-orient and adhere upon fluid loss to produce significant variations in the mechanical response to compression. Here, we model their micromechanics by introducing an aggregation force and a critical yield pressure into the constitutive formulation for transversely isotropic biphasic materials. The resulting model is easy to implement for routine characterization of this type of hydrated biomaterials through unconfined compression testing and produces physically meaningful and reproducible mechanical parameters.
Collapse
|
19
|
Chen X, Zhou Y, Wang L, Santare MH, Wan LQ, Lu XL. Determining Tension-Compression Nonlinear Mechanical Properties of Articular Cartilage from Indentation Testing. Ann Biomed Eng 2015; 44:1148-58. [PMID: 26240062 DOI: 10.1007/s10439-015-1402-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2015] [Accepted: 07/18/2015] [Indexed: 11/30/2022]
Abstract
The indentation test is widely used to determine the in situ biomechanical properties of articular cartilage. The mechanical parameters estimated from the test depend on the constitutive model adopted to analyze the data. Similar to most connective tissues, the solid matrix of cartilage displays different mechanical properties under tension and compression, termed tension-compression nonlinearity (TCN). In this study, cartilage was modeled as a porous elastic material with either a conewise linear elastic matrix with cubic symmetry or a solid matrix reinforced by a continuous fiber distribution. Both models are commonly used to describe the TCN of cartilage. The roles of each mechanical property in determining the indentation response of cartilage were identified by finite element simulation. Under constant loading, the equilibrium deformation of cartilage is mainly dependent on the compressive modulus, while the initial transient creep behavior is largely regulated by the tensile stiffness. More importantly, altering the permeability does not change the shape of the indentation creep curves, but introduces a parallel shift along the horizontal direction on a logarithmic time scale. Based on these findings, a highly efficient curve-fitting algorithm was designed, which can uniquely determine the three major mechanical properties of cartilage (compressive modulus, tensile modulus, and permeability) from a single indentation test. The new technique was tested on adult bovine knee cartilage and compared with results from the classic biphasic linear elastic curve-fitting program.
Collapse
Affiliation(s)
- Xingyu Chen
- Department of Mechanical Engineering, University of Delaware, 130 Academy Street SPL 126, Newark, DE, 19716, USA
| | - Yilu Zhou
- Department of Mechanical Engineering, University of Delaware, 130 Academy Street SPL 126, Newark, DE, 19716, USA
| | - Liyun Wang
- Department of Mechanical Engineering, University of Delaware, 130 Academy Street SPL 126, Newark, DE, 19716, USA
| | - Michael H Santare
- Department of Mechanical Engineering, University of Delaware, 130 Academy Street SPL 126, Newark, DE, 19716, USA
| | - Leo Q Wan
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180, USA
| | - X Lucas Lu
- Department of Mechanical Engineering, University of Delaware, 130 Academy Street SPL 126, Newark, DE, 19716, USA.
| |
Collapse
|
20
|
Misra A, Parthasarathy R, Singh V, Spencer P. Micro-poromechanics model of fluid-saturated chemically active fibrous media. ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK 2015; 95:215-234. [PMID: 25755301 PMCID: PMC4351821 DOI: 10.1002/zamm.201300071] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We have developed a micromechanics based model for chemically active saturated fibrous media that incorporates fiber network microstructure, chemical potential driven fluid flow, and micro-poromechanics. The stress-strain relationship of the dry fibrous media is first obtained by considering the fiber behavior. The constitutive relationships applicable to saturated media are then derived in the poromechanics framework using Hill's volume averaging. The advantage of this approach is that the resultant continuum model accounts for the discrete nature of the individual fibers while retaining a form suitable for porous materials. As a result, the model is able to predict the influence of micro-scale phenomena, such as the fiber pre-strain caused by osmotic effects and evolution of fiber network structure with loading, on the overall behavior and in particular, on the poromechanics parameters. Additionally, the model can describe fluid-flow related rate-dependent behavior under confined and unconfined conditions and varying chemical environments. The significance of the approach is demonstrated by simulating unconfined drained monotonic uniaxial compression under different surrounding fluid bath molarity, and fluid-flow related creep and relaxation at different loading-levels and different surrounding fluid bath molarity. The model predictions conform to the experimental observations for saturated soft fibrous materials. The method can potentially be extended to other porous materials such as bone, clays, foams and concrete.
Collapse
Affiliation(s)
- Anil Misra
- University of Kansas, Civil, Environmental and Architectural Engineering Department, Lawrence, KS 66045, USA
- University of Kansas, Bioengineering Research Center (BERC), Lawrence, KS 66045, USA
| | - Ranganathan Parthasarathy
- University of Kansas, Bioengineering Research Center (BERC), Lawrence, KS 66045, USA
- University of Kansas, Bioengineering Graduate Program, Lawrence, KS 66045, USA
| | - Viraj Singh
- University of Kansas, Mechanical Engineering Department, Lawrence, KS 66045, USA
| | - Paulette Spencer
- University of Kansas, Bioengineering Research Center (BERC), Lawrence, KS 66045, USA
- University of Kansas, Mechanical Engineering Department, Lawrence, KS 66045, USA
| |
Collapse
|
21
|
June RK, Fyhrie DP. A comparison of cartilage stress-relaxation models in unconfined compression: QLV and stretched exponential in combination with fluid flow. Comput Methods Biomech Biomed Engin 2013; 16:565-76. [DOI: 10.1080/10255842.2011.629612] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
22
|
Henak CR, Anderson AE, Weiss JA. Subject-specific analysis of joint contact mechanics: application to the study of osteoarthritis and surgical planning. J Biomech Eng 2013; 135:021003. [PMID: 23445048 PMCID: PMC3705883 DOI: 10.1115/1.4023386] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2012] [Revised: 01/03/2013] [Accepted: 01/18/2013] [Indexed: 11/08/2022]
Abstract
Advances in computational mechanics, constitutive modeling, and techniques for subject-specific modeling have opened the door to patient-specific simulation of the relationships between joint mechanics and osteoarthritis (OA), as well as patient-specific preoperative planning. This article reviews the application of computational biomechanics to the simulation of joint contact mechanics as relevant to the study of OA. This review begins with background regarding OA and the mechanical causes of OA in the context of simulations of joint mechanics. The broad range of technical considerations in creating validated subject-specific whole joint models is discussed. The types of computational models available for the study of joint mechanics are reviewed. The types of constitutive models that are available for articular cartilage are reviewed, with special attention to choosing an appropriate constitutive model for the application at hand. Issues related to model generation are discussed, including acquisition of model geometry from volumetric image data and specific considerations for acquisition of computed tomography and magnetic resonance imaging data. Approaches to model validation are reviewed. The areas of parametric analysis, factorial design, and probabilistic analysis are reviewed in the context of simulations of joint contact mechanics. Following the review of technical considerations, the article details insights that have been obtained from computational models of joint mechanics for normal joints; patient populations; the study of specific aspects of joint mechanics relevant to OA, such as congruency and instability; and preoperative planning. Finally, future directions for research and application are summarized.
Collapse
Affiliation(s)
- Corinne R. Henak
- Department of Bioengineering,University of Utah,Salt Lake City, UT 84112;Scientific Computing and Imaging Institute,University of Utah,Salt Lake City, UT 84112
| | - Andrew E. Anderson
- Department of Bioengineering,University of Utah,Salt Lake City, UT;Scientific Computing and Imaging Institute,University of Utah,Salt Lake City, UT;Department of Orthopaedics,University of Utah,Salt Lake City, UT 84108;Department of Physical Therapy,University of Utah,Salt Lake City, UT 84108
| | - Jeffrey A. Weiss
- Department of Bioengineering,University of Utah,Salt Lake City, UT 84108;Scientific Computing and Imaging Institute,University of Utah,Salt Lake City, UT 84108;Department of Orthopaedics,University of Utah,Salt Lake City, UT 84108e-mail:
| |
Collapse
|
23
|
Screen HRC, Toorani S, Shelton JC. Microstructural stress relaxation mechanics in functionally different tendons. Med Eng Phys 2012; 35:96-102. [PMID: 22652381 DOI: 10.1016/j.medengphy.2012.04.004] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2011] [Revised: 04/01/2012] [Accepted: 04/15/2012] [Indexed: 11/19/2022]
Abstract
Tendons experience widely varying loading conditions in vivo. They may be categorised by their function as either positional tendons, which are used for intricate movements and experience lower stress, or as energy storage tendons which act as highly stressed springs during locomotion. Structural and compositional differences between tendons are thought to enable an optimisation of their properties to suit their functional environment. However, little is known about structure-function relationships in tendon. This study adopts porcine flexor and extensor tendon fascicles as examples of high stress and low stress tendons, comparing their mechanical behaviour at the micro-level in order to understand their stress relaxation response. Stress-relaxation was shown to occur predominantly through sliding between collagen fibres. However, in the more highly stressed flexor tendon fascicles, more fibre reorganisation was evident when the tissue was exposed to low strains. By contrast, the low load extensor tendon fascicles appears to have less capacity for fibre reorganisation or shearing than the energy storage tendon, relying more heavily on fibril level relaxation. The extensor fascicles were also unable to sustain loads without rapid and complete stress relaxation. These findings highlight the need to optimise tendon repair solutions for specific tendons, and match tendon properties when using grafts in tendon repairs.
Collapse
Affiliation(s)
- H R C Screen
- School of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, London E1 4NS, UK.
| | | | | |
Collapse
|
24
|
Changoor A, Coutu JP, Garon M, Quenneville E, Hurtig MB, Buschmann MD. Streaming potential-based arthroscopic device is sensitive to cartilage changes immediately post-impact in an equine cartilage injury model. J Biomech Eng 2011; 133:061005. [PMID: 21744925 DOI: 10.1115/1.4004230] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Models of post-traumatic osteoarthritis where early degenerative changes can be monitored are valuable for assessing potential therapeutic strategies. Current methods for evaluating cartilage mechanical properties may not capture the low-grade cartilage changes expected at these earlier time points following injury. In this study, an explant model of cartilage injury was used to determine whether streaming potential measurements by manual indentation could detect cartilage changes immediately following mechanical impact and to compare their sensitivity to biomechanical tests. Impacts were delivered ex vivo, at one of three stress levels, to specific positions on isolated adult equine trochlea. Cartilage properties were assessed by streaming potential measurements, made pre- and post-impact using a commercially available arthroscopic device, and by stress relaxation tests in unconfined compression geometry of isolated cartilage disks, providing the streaming potential integral (SPI), fibril modulus (Ef), matrix modulus (Em), and permeability (k). Histological sections were stained with Safranin-O and adjacent unstained sections examined in polarized light microscopy. Impacts were low, 17.3 ± 2.7 MPa (n = 15), medium, 27.8 ± 8.5 MPa (n = 13), or high, 48.7 ± 12.1 MPa (n = 16), and delivered using a custom-built spring-loaded device with a rise time of approximately 1 ms. SPI was significantly reduced after medium (p = 0.006) and high (p<0.001) impacts. Ef, representing collagen network stiffness, was significantly reduced in high impact samples only (p < 0.001 lateral trochlea, p = 0.042 medial trochlea), where permeability also increased (p = 0.003 lateral trochlea, p = 0.007 medial trochlea). Significant (p < 0.05, n = 68) moderate to strong correlations between SPI and Ef (r = 0.857), Em (r = 0.493), log(k) (r = -0.484), and cartilage thickness (r = -0.804) were detected. Effect sizes were higher for SPI than Ef, Em, and k, indicating greater sensitivity of electromechanical measurements to impact injury compared to purely biomechanical parameters. Histological changes due to impact were limited to the presence of superficial zone damage which increased with impact stress. Non-destructive streaming potential measurements were more sensitive to impact-related articular cartilage changes than biomechanical assessment of isolated samples using stress relaxation tests in unconfined compression geometry. Correlations between electromechanical and biomechanical methods further support the relationship between non-destructive electromechanical measurements and intrinsic cartilage properties.
Collapse
Affiliation(s)
- A Changoor
- Department of Chemical Engineering, Institute of Biomedical Engineering, École Polytechnique de Montréal, P.O. Box 6079, Station Centre-Ville Montreal, QC H3C3A7, Canada
| | | | | | | | | | | |
Collapse
|
25
|
Roberts JJ, Earnshaw A, Ferguson VL, Bryant SJ. Comparative study of the viscoelastic mechanical behavior of agarose and poly(ethylene glycol) hydrogels. J Biomed Mater Res B Appl Biomater 2011; 99:158-69. [DOI: 10.1002/jbm.b.31883] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2010] [Revised: 03/13/2011] [Accepted: 04/10/2011] [Indexed: 11/08/2022]
|
26
|
Wosu R, Sergerie K, Lévesque M, Villemure I. Mechanical properties of the porcine growth plate vary with developmental stage. Biomech Model Mechanobiol 2011; 11:303-12. [DOI: 10.1007/s10237-011-0310-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2010] [Accepted: 04/21/2011] [Indexed: 10/18/2022]
|
27
|
June RK, Neu CP, Barone JR, Fyhrie DP. Polymer Mechanics as a Model for Short-Term and Flow-Independent Cartilage Viscoelasticity. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2011; 31:781-788. [PMID: 21552375 PMCID: PMC3087607 DOI: 10.1016/j.msec.2010.11.029] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Articular cartilage is the load bearing soft tissue that covers the contacting surfaces of long bones in articulating joints. Healthy cartilage allows for smooth joint motion, while damaged cartilage prohibits normal function in debilitating joint diseases such as osteoarthritis. Knowledge of cartilage mechanical function through the progression of osteoarthritis, and in response to innovative regeneration treatments, requires a comprehensive understanding of the molecular nature of interacting extracellular matrix constituents and interstitial fluid. The objectives of this study were therefore to (1) examine the timescale of cartilage stress-relaxation using different mechanistic models and (2) develop and apply a novel (termed "sticky") polymer mechanics model to cartilage stress-relaxation based on temporary binding of constituent macromolecules. Using data from calf cartilage samples, we found that different models captured distinct timescales of cartilage stress-relaxation: monodisperse polymer reptation best described the first second of relaxation, sticky polymer mechanics best described data from ∼1-100 seconds of relaxation, and a model of inviscid fluid flow through a porous elastic matrix best described data from 100 seconds to equilibrium. Further support for the sticky polymer model was observed using experimental data where cartilage stress-relaxation was measured in either low or high salt concentration. These data suggest that a complete understanding of cartilage mechanics, especially in the short time scales immediately following loading, requires appreciation of both fluid flow and the polymeric behavior of the extracellular matrix.
Collapse
Affiliation(s)
- R. K. June
- Department of Cellular and Molecular Medicine, University of California, San Diego, San Diego, CA, 92093
| | - C. P. Neu
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, 47907
| | - J. R. Barone
- Biological Systems Engineering, Virginia Technological University, Blacksburg, VA, 24060
| | - D. P. Fyhrie
- Department of Orthopaedic Surgery, University of California, Davis, Medical Center, Sacramento, CA, 95817
| |
Collapse
|
28
|
Hurtig MB, Buschmann MD, Fortier LA, Hoemann CD, Hunziker EB, Jurvelin JS, Mainil-Varlet P, McIlwraith CW, Sah RL, Whiteside RA. Preclinical Studies for Cartilage Repair: Recommendations from the International Cartilage Repair Society. Cartilage 2011; 2:137-52. [PMID: 26069576 PMCID: PMC4300779 DOI: 10.1177/1947603511401905] [Citation(s) in RCA: 104] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Investigational devices for articular cartilage repair or replacement are considered to be significant risk devices by regulatory bodies. Therefore animal models are needed to provide proof of efficacy and safety prior to clinical testing. The financial commitment and regulatory steps needed to bring a new technology to clinical use can be major obstacles, so the implementation of highly predictive animal models is a pressing issue. Until recently, a reductionist approach using acute chondral defects in immature laboratory species, particularly the rabbit, was considered adequate; however, if successful and timely translation from animal models to regulatory approval and clinical use is the goal, a step-wise development using laboratory animals for screening and early development work followed by larger species such as the goat, sheep and horse for late development and pivotal studies is recommended. Such animals must have fully organized and mature cartilage. Both acute and chronic chondral defects can be used but the later are more like the lesions found in patients and may be more predictive. Quantitative and qualitative outcome measures such as macroscopic appearance, histology, biochemistry, functional imaging, and biomechanical testing of cartilage, provide reliable data to support investment decisions and subsequent applications to regulatory bodies for clinical trials. No one model or species can be considered ideal for pivotal studies, but the larger animal species are recommended for pivotal studies. Larger species such as the horse, goat and pig also allow arthroscopic delivery, and press-fit or sutured implant fixation in thick cartilage as well as second look arthroscopies and biopsy procedures.
Collapse
|
29
|
Changoor A, Fereydoonzad L, Yaroshinsky A, Buschmann MD. Effects of Refrigeration and Freezing on the Electromechanical and Biomechanical Properties of Articular Cartilage. J Biomech Eng 2010; 132:064502. [PMID: 20887036 DOI: 10.1115/1.4000991] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In vitro electromechanical and biomechanical testing of articular cartilage provide critical information about the structure and function of this tissue. Difficulties obtaining fresh tissue and lengthy experimental testing procedures often necessitate a storage protocol, which may adversely affect the functional properties of cartilage. The effects of storage at either 4°C for periods of 6 days and 12 days, or during a single freeze-thaw cycle at −20°C were examined in young bovine cartilage. Non-destructive electromechanical measurements and unconfined compression testing on 3 mm diameter disks were used to assess cartilage properties, including the streaming potential integral (SPI), fibril modulus (Ef), matrix modulus (Em), and permeability (k). Cartilage disks were also examined histologically. Compared with controls, significant decreases in SPI (to 32.3±5.5% of control values, p<0.001), Ef (to 3.1±41.3% of control values, p=0.046), Em (to 6.4±8.5% of control values, p<0.0001), and an increase in k (to 2676.7±2562.0% of control values, p=0.004) were observed at day 12 of refrigeration at 4°C, but no significant changes were detected at day 6. A trend toward detecting a decrease in SPI (to 94.2±6.2% of control values, p=0.083) was identified following a single freeze-thaw cycle, but no detectable changes were observed for any biomechanical parameters. All numbers are mean±95% confidence interval. These results indicate that fresh cartilage can be stored in a humid chamber at 4°C for a maximum of 6 days with no detrimental effects to cartilage electromechanical and biomechanical properties, while one freeze-thaw cycle produces minimal deterioration of biomechanical and electromechanical properties. A comparison to literature suggested that particular attention should be paid to the manner in which specimens are thawed after freezing, specifically by minimizing thawing time at higher temperatures.
Collapse
Affiliation(s)
- Adele Changoor
- Biomaterials and Cartilage Laboratory, École Polytechnique de Montréal, P. O. Box 6079, Station Centre-ville, Montréal, QC H3C 3A7, Canada
| | - Liah Fereydoonzad
- Biomaterials and Cartilage Laboratory, École Polytechnique de Montréal, P. O. Box 6079, Station Centre-ville, Montréal, QC H3C 3A7, Canada
| | | | - Michael D. Buschmann
- Biomaterials and Cartilage Laboratory, École Polytechnique de Montréal, P. O. Box 6079, Station Centre-ville, Montréal, QC H3C 3A7, Canada
| |
Collapse
|
30
|
June RK, Fyhrie DP. Enzymatic digestion of articular cartilage results in viscoelasticity changes that are consistent with polymer dynamics mechanisms. Biomed Eng Online 2009; 8:32. [PMID: 19889234 PMCID: PMC2778644 DOI: 10.1186/1475-925x-8-32] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2009] [Accepted: 11/04/2009] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Cartilage degeneration via osteoarthritis affects millions of elderly people worldwide, yet the specific contributions of matrix biopolymers toward cartilage viscoelastic properties remain unknown despite 30 years of research. Polymer dynamics theory may enable such an understanding, and predicts that cartilage stress-relaxation will proceed faster when the average polymer length is shortened. METHODS This study tested whether the predictions of polymer dynamics were consistent with changes in cartilage mechanics caused by enzymatic digestion of specific cartilage extracellular matrix molecules. Bovine calf cartilage explants were cultured overnight before being immersed in type IV collagenase, bacterial hyaluronidase, or control solutions. Stress-relaxation and cyclical loading tests were performed after 0, 1, and 2 days of incubation. RESULTS Stress-relaxation proceeded faster following enzymatic digestion by collagenase and bacterial hyaluronidase after 1 day of incubation (both p < or = 0.01). The storage and loss moduli at frequencies of 1 Hz and above were smaller after 1 day of digestion by collagenase and bacterial hyaluronidase (all p < or = 0.02). CONCLUSION These results demonstrate that enzymatic digestion alters cartilage viscoelastic properties in a manner consistent with polymer dynamics mechanisms. Future studies may expand the use of polymer dynamics as a microstructural model for understanding the contributions of specific matrix molecules toward tissue-level viscoelastic properties.
Collapse
Affiliation(s)
- Ronald K June
- Department of Cellular and Molecular Medicine, University of California, San Diego, La Jolla, USA.
| | | |
Collapse
|
31
|
Gupta S, Lin J, Ashby P, Pruitt L. A fiber reinforced poroelastic model of nanoindentation of porcine costal cartilage: A combined experimental and finite element approach. J Mech Behav Biomed Mater 2009; 2:326-37; discussion 337-8. [DOI: 10.1016/j.jmbbm.2008.09.003] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2008] [Revised: 08/26/2008] [Accepted: 09/29/2008] [Indexed: 11/28/2022]
|
32
|
Shields KJ, Owen JR, Wayne JS. Biomechanical and Biotribological Correlation of Induced Wear on Bovine Femoral Condyles. J Biomech Eng 2009; 131:061005. [DOI: 10.1115/1.3116156] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Characterizing the biomechanical and biotribological properties for articular surfaces in healthy, damaged, and repaired states will both elucidate the understanding of mechanical degradation and lubricating phenomena and enhance the development of functional tissue engineered cartilage and surgical repair techniques. In recent work, a new methodology involving concomitant linear translational and oscillating rotational motion was developed to determine the frictional and wear characteristics of articular cartilage. The impetus of this work was to further characterize the biomechanical characteristics from stress relaxation and dynamic cyclical indentation testing of normal and damaged articular cartilage and to correlate the biotribological characteristic findings with the biomechanical data. Quasilinear viscoelastic (QLV) theory was used to curve fit the stress-relaxation data, while the dynamic data were used both to determine the dynamic properties through fast Fourier transform analysis and to validate the dynamic behavior based on the properties obtained from the QLV theory. Comparisons of the curve-fit parameters showed a significant decrease in pre- versus postwear elastic response, A(p<0.04), and viscous response, c(p<0.01). In addition, the short term relaxation time, τ1(p<0.0062), showed a significant decrease between surfaces with and without a defect. The magnitude of the complex modulus from dynamic tests revealed a decrease due to wear, lGlpostwear∕lGlprewear<1(p<0.05). The loss factor, tanδ, was generally greater while lGl was less for those specimens experiencing rotation. A linear regression analysis was performed to correlate μstatic and μinitial with the curve-fit QLV parameters, A, B, c, τ1, and τ2. Increasing coefficients of friction correlated with decreases in the elastic response, A, viscous response, c, and the short term relaxation time constant, τ1, while B became increasingly nonlinear and τ2 became shorter postwear. Qualitatively, scanning electron microscopy photographs revealed the mechanical degradation of the tissue surface due to wear. Surfaces with a defect had an increased amount of wear debris, which ultimately contributed to third body wear. Surfaces without a defect had preferentially aligned abrasions, while those surfaces not within the wear path showed no signs of wear. The efficacy of various repair techniques and innovative repair tissue models in comparison to normal and worn articular surface tissue can be determined through experimental designs involving both biomechanical and biotribological parameter characterizations. The development of this comprehensive testing scenario involving both biotribological and biomechanical characteristics is essential to the continued development of potential articular repair tissue.
Collapse
Affiliation(s)
- Kelly J. Shields
- Department of Biomedical Engineering and Department of Orthopaedic Surgery, Orthopaedic Research Laboratory, Virginia Commonwealth University, Richmond, VA 23284-3067
| | - John R. Owen
- Department of Biomedical Engineering and Department of Orthopaedic Surgery, Orthopaedic Research Laboratory, Virginia Commonwealth University, Richmond, VA 23284-3067
| | - Jennifer S. Wayne
- Department of Biomedical Engineering and Department of Orthopaedic Surgery, Orthopaedic Research Laboratory, Virginia Commonwealth University, Richmond, VA 23284-3067
| |
Collapse
|
33
|
June RK, Ly S, Fyhrie DP. Cartilage stress-relaxation proceeds slower at higher compressive strains. Arch Biochem Biophys 2008; 483:75-80. [PMID: 19111671 DOI: 10.1016/j.abb.2008.11.029] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2008] [Revised: 11/20/2008] [Accepted: 11/29/2008] [Indexed: 11/24/2022]
Abstract
Articular cartilage is the connective tissue which covers bone surfaces and deforms during in vivo activity. Previous research has investigated flow-dependent cartilage viscoelasticity, but relatively few studies have investigated flow-independent mechanisms. This study investigated polymer dynamics as an explanation for the molecular basis of flow-independent cartilage viscoelasticity. Polymer dynamics predicts that stress-relaxation will proceed more slowly at higher volumetric concentrations of polymer. Stress-relaxation tests were performed on cartilage samples after precompression to different strain levels. Precompression increases the volumetric concentration of cartilage biopolymers, and polymer dynamics predicts an increase in relaxation time constant. Stress-relaxation was slower for greater precompression. There was a significant correlation between the stress-relaxation time constant and cartilage volumetric concentration. Estimates of the flow-dependent timescale suggest that flow-dependent relaxation occurs on a longer timescale than presently observed. These results are consistent with polymer dynamics as a mechanism of cartilage viscoelasticity.
Collapse
Affiliation(s)
- Ronald K June
- UCSD, Department of Cellular and Molecular Medicine, La Jolla, CA 92093-0686, USA.
| | | | | |
Collapse
|
34
|
Korhonen RK, Julkunen P, Wilson W, Herzog W. Importance of collagen orientation and depth-dependent fixed charge densities of cartilage on mechanical behavior of chondrocytes. J Biomech Eng 2008; 130:021003. [PMID: 18412490 DOI: 10.1115/1.2898725] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The collagen network and proteoglycan matrix of articular cartilage are thought to play an important role in controlling the stresses and strains in and around chondrocytes, in regulating the biosynthesis of the solid matrix, and consequently in maintaining the health of diarthrodial joints. Understanding the detailed effects of the mechanical environment of chondrocytes on cell behavior is therefore essential for the study of the development, adaptation, and degeneration of articular cartilage. Recent progress in macroscopic models has improved our understanding of depth-dependent properties of cartilage. However, none of the previous works considered the effect of realistic collagen orientation or depth-dependent negative charges in microscopic models of chondrocyte mechanics. The aim of this study was to investigate the effects of the collagen network and fixed charge densities of cartilage on the mechanical environment of the chondrocytes in a depth-dependent manner. We developed an anisotropic, inhomogeneous, microstructural fibril-reinforced finite element model of articular cartilage for application in unconfined compression. The model consisted of the extracellular matrix and chondrocytes located in the superficial, middle, and deep zones. Chondrocytes were surrounded by a pericellular matrix and were assumed spherical prior to tissue swelling and load application. Material properties of the chondrocytes, pericellular matrix, and extracellular matrix were obtained from the literature. The loading protocol included a free swelling step followed by a stress-relaxation step. Results from traditional isotropic and transversely isotropic biphasic models were used for comparison with predictions from the current model. In the superficial zone, cell shapes changed from rounded to elliptic after free swelling. The stresses and strains as well as fluid flow in cells were greatly affected by the modulus of the collagen network. The fixed charge density of the chondrocytes, pericellular matrix, and extracellular matrix primarily affected the aspect ratios (height/width) and the solid matrix stresses of cells. The mechanical responses of the cells were strongly location and time dependent. The current model highlights that the collagen orientation and the depth-dependent negative fixed charge densities of articular cartilage have a great effect in modulating the mechanical environment in the vicinity of chondrocytes, and it provides an important improvement over earlier models in describing the possible pathways from loading of articular cartilage to the mechanical and biological responses of chondrocytes.
Collapse
Affiliation(s)
- Rami K Korhonen
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, T2N 1N4, Canada.
| | | | | | | |
Collapse
|
35
|
Shirazi R, Shirazi-Adl A. Deep vertical collagen fibrils play a significant role in mechanics of articular cartilage. J Orthop Res 2008; 26:608-15. [PMID: 18050338 DOI: 10.1002/jor.20537] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The primary orientation of collagen fibrils alters along the cartilage depth; being horizontal in the superficial zone, random in the transitional zone, and vertical in the deep zone. Commonly used confined and unconfined (when with no underlying bone) testing configurations cannot capture the mechanical role of deep vertical fibril network. To determine this role in cartilage mechanics, an axisymmetric nonlinear fibril-reinforced poroelastic model of tibial cartilage plateaus was developed accounting for depth-dependent properties and distinct fibril networks with physical material properties. Both creep and relaxation indentation models were analyzed which results were found equivalent in the transient period but diverged in post-transient periods. Vertical fibrils played a significant role at the transient period in dramatically increasing the stiffness of the tissue and in protecting the solid matrix against large distortions and strains at the subchondral junction. This role, however, disappeared both with time and at loading rates slower than those expected in physiological activities such as walking. The vertical fibrils demonstrated a chevron-type deformation pattern that was further accentuated with time in creep loading. Damages to deep vertical collagen fibril network or their firm anchorage to the bone, associated with bone bruises, for example, would weaken the transient stiffness and place the tissue at higher risk of failure particularly at the deep zone.
Collapse
Affiliation(s)
- R Shirazi
- Division of Applied Mechanics, Department of Mechanical Engineering, Ecole Polytechnique, P.O. Box 6079, Station centre-ville, Montréal, Québec, Canada
| | | |
Collapse
|
36
|
Rosen J, Brown JD, De S, Sinanan M, Hannaford B. Biomechanical Properties of Abdominal Organs In Vivo and Postmortem Under Compression Loads. J Biomech Eng 2008; 130:021020. [PMID: 18412507 DOI: 10.1115/1.2898712] [Citation(s) in RCA: 160] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Accurate knowledge of biomechanical characteristics of tissues is essential for developing realistic computer-based surgical simulators incorporating haptic feedback, as well as for the design of surgical robots and tools. As simulation technologies continue to be capable of modeling more complex behavior, an in vivo tissue property database is needed. Most past and current biomechanical research is focused on soft and hard anatomical structures that are subject to physiological loading, testing the organs in situ. Internal organs are different in that respect since they are not subject to extensive loads as part of their regular physiological function. However, during surgery, a different set of loading conditions are imposed on these organs as a result of the interaction with the surgical tools. Following previous research studying the kinematics and dynamics of tool/tissue interaction in real surgical procedures, the focus of the current study was to obtain the structural biomechanical properties (engineering stress-strain and stress relaxation) of seven abdominal organs, including bladder, gallbladder, large and small intestines, liver, spleen, and stomach, using a porcine animal model. The organs were tested in vivo, in situ, and ex corpus (the latter two conditions being postmortem) under cyclical and step strain compressions using a motorized endoscopic grasper and a universal-testing machine. The tissues were tested with the same loading conditions commonly applied by surgeons during minimally invasive surgical procedures. Phenomenological models were developed for the various organs, testing conditions, and experimental devices. A property database—unique to the literature—has been created that contains the average elastic and relaxation model parameters measured for these tissues in vivo and postmortem. The results quantitatively indicate the significant differences between tissue properties measured in vivo and postmortem. A quantitative understanding of how the unconditioned tissue properties and model parameters are influenced by time postmortem and loading condition has been obtained. The results provide the material property foundations for developing science-based haptic surgical simulators, as well as surgical tools for manual and robotic systems.
Collapse
Affiliation(s)
- Jacob Rosen
- Department of Electrical Engineering, University of Washington, Box 352500, Seattle, WA 98195-2500
| | - Jeffrey D. Brown
- Department of Bioengineering, University of Washington, Box 352500, Seattle, WA 98195-2500
| | - Smita De
- Department of Bioengineering, University of Washington, Box 352500, Seattle, WA 98195-2500
| | - Mika Sinanan
- Department of Surgery, University of Washington, Box 356410, Seattle, WA 98195-2500
| | - Blake Hannaford
- Department of Electrical Engineering, University of Washington, Box 352500, Seattle, WA 98195-2500
| |
Collapse
|
37
|
Burgin LV, Aspden RM. Impact testing to determine the mechanical properties of articular cartilage in isolation and on bone. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2008; 19:703-11. [PMID: 17619965 DOI: 10.1007/s10856-007-3187-2] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2007] [Accepted: 05/21/2007] [Indexed: 05/16/2023]
Abstract
The biomechanical response of cartilage to impact loads, both in isolation and in situ on its bone substrate, has been little studied despite the common occurrence of osteoarthritis subsequent to cartilage injury. An instrumented drop tower was used to apply controlled impact loads of different energies to explants of bovine articular cartilage. Results were compared with a conventional slow stress-strain test. The effects of the underlying bone were investigated by progressively shortening a core of bone removed with the cartilage, and by gluing cartilage samples to substrates of different moduli. The maximum dynamic modulus of isolated samples of bovine articular cartilage, at strain rates between 1100 and 1500 s(-1), was approximately two orders of magnitude larger than the quasistatic modulus and varied non-linearly with applied stress. When attached to a substrate of higher modulus, increasing the thickness of the substrate increased the effective modulus of the combination until a steady value was achieved. A lower modulus substrate reduced the effective modulus of the combination. Severe impacts resulted in damage to the bone rather than to the cartilage. The modulus of cartilage rises rapidly and non-linearly with strain rate, giving the tissue a remarkable ability to withstand impact loads. The presence of cartilage attenuated the peak force experienced by the bone and spread the impact loading period over a longer time.
Collapse
Affiliation(s)
- Leanne V Burgin
- Department of Orthopaedics, Institute of Medical Sciences, University of Aberdeen, Foresterhill, Aberdeen, UK
| | | |
Collapse
|
38
|
Ling HY, Zheng YP, Patil SG. Strain dependence of ultrasound speed in bovine articular cartilage under compression in vitro. ULTRASOUND IN MEDICINE & BIOLOGY 2007; 33:1599-608. [PMID: 17602828 DOI: 10.1016/j.ultrasmedbio.2007.04.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2006] [Revised: 04/23/2007] [Accepted: 04/26/2007] [Indexed: 05/16/2023]
Abstract
The change of the ultrasound (US) speed in articular cartilage (artC) under applied strain conditions may induce significant measurement errors of the mechanical properties of the artC during both indentation and compression tests using US. In this paper, the strain dependence of the US speed in bovine artC (n = 20) under compression in vitro was investigated by virtue of using a custom-made US compression testing system. The US speed of the artC at the instant after the compression and that after a period of stress-relaxation were estimated under the applied strain ranging from 0% to 20%. Moreover, the instantaneous modulus and the modulus after the stress-relaxation of the artC were measured and correlated with the US speed. There was no significant difference (p > 0.05) between the US speed at the instant after the compression and that after the stress-relaxation, although there was a discrepancy between the instantaneous modulus and the modulus after stress-relaxation. The US speed was found to be highly correlated to the applied strain (r(2) = 0.98, p < 0.001) in a quadratic relation and changed by 7.8% (from 1581 +/- 36 m/s to 1671 +/- 56 m/s) when the applied strain reached 20%. The results suggest that the strain-dependent effect on the US speed in artC should be considered when the US is deployed for the assessment of artC using the compression or indentation test.
Collapse
Affiliation(s)
- H Y Ling
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China.
| | | | | |
Collapse
|
39
|
Young AA, Appleyard RC, Smith MM, Melrose J, Little CB. Dynamic biomechanics correlate with histopathology in human tibial cartilage: a preliminary study. Clin Orthop Relat Res 2007; 462:212-20. [PMID: 17496559 DOI: 10.1097/blo.0b013e318076b431] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Improved staging of cartilage degeneration is required, particularly during early stages when minimal surface damage is visible arthroscopically. Degradation of articular cartilage extracellular matrix, resulting from degenerative changes associated with osteoarthritis, can influence its functional properties. Cartilage mechanical properties therefore may provide a quantitative method for monitoring degenerative change in this tissue. We determined whether dynamic mechanical properties of cartilage (effective shear modulus and phase lag) measured with a handheld indenter correlated with histopathology scores, proteoglycan, and collagen content or expression of chondrocyte-specific (aggrecan, collagen II) or dedifferentiation (collagen I and III) genes in human osteoarthritic cartilage with International Cartilage Repair Society scores of 0 to 1. We observed an association between the histopathologic stage of cartilage disease and dynamic shear modulus and phase lag. In contrast, there generally was a poor relationship between cartilage biomechanical properties and biochemistry with the only noteworthy correlation being between shear modulus and collagen. Phase lag but not shear modulus correlated with gene expression. These data support the potential of dynamic indentation for assessing the stage of cartilage degeneration in tissue with minimal gross surface damage.
Collapse
Affiliation(s)
- Allan A Young
- Raymond Purves Research Laboratory, Institute of Bone and Joint Research, Kolling Institute of Medical Research, University of Sydney at Royal North Shore Hospital, Sydney, Australia
| | | | | | | | | |
Collapse
|
40
|
Goreham-Voss CM, McKinley TO, Brown TD. A finite element exploration of cartilage stress near an articular incongruity during unstable motion. J Biomech 2007; 40:3438-47. [PMID: 17604036 PMCID: PMC2212609 DOI: 10.1016/j.jbiomech.2007.05.023] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2007] [Revised: 05/21/2007] [Accepted: 05/21/2007] [Indexed: 11/30/2022]
Abstract
Both instability and residual articular incongruity are implicated in the development of post-traumatic osteoarthritis (OA) following intra-articular fracture, but currently no information exists regarding cartilage stresses for unstable residual incongruities. In this study, a transversely isotropic poroelastic cartilage finite element model was implemented and validated within physiologically relevant loading ranges. This material model was then used to simulate the loading of cartilage during stable and unstable motion accompanying a step-off incongruity residual from intra-articular fracture, using load data from previous cadaver tests of ankle instability. Peak solid-phase stresses and fluid pressure were found to increase markedly in the presence of instability. Solid-phase transients of normal stress increased from 2.00 to 13.8 MPa/s for stable compared to unstable motion, and tangential stress transients increased from 17.1 to 118.1 MPa/s. Corresponding fluid pressure transients increased from 15.1 to 117.9 MPa/s for unstable motion. In the most rapidly loaded sections of cartilage, the fluid was found to carry nearly all of the normal load, with the pressurization of the fluid resulting in high solid matrix tangential stresses.
Collapse
Affiliation(s)
| | - Todd O. McKinley
- Department of Orthopaedics and Rehabilitation, University of Iowa
| | - Thomas D. Brown
- Department of Orthopaedics and Rehabilitation, University of Iowa
- Department of Mechanical Engineering, University of Iowa
- Department of Biomedical Engineering, University of Iowa
| |
Collapse
|
41
|
Li LP, Korhonen RK, Iivarinen J, Jurvelin JS, Herzog W. Fluid pressure driven fibril reinforcement in creep and relaxation tests of articular cartilage. Med Eng Phys 2007; 30:182-9. [PMID: 17524700 DOI: 10.1016/j.medengphy.2007.03.001] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2006] [Revised: 02/27/2007] [Accepted: 03/02/2007] [Indexed: 11/22/2022]
Abstract
Biological tissues exhibit diverse mechanical behaviors because of complex material properties. As has been shown for ligaments and intervertebral discs, mathematical models often appear to well predict load responses individually by adjusting model parameters, but likely fail to describe several different load responses simultaneously using the same model parameters. In the present study, we attempted to describe and explain both creep and relaxation responses of articular cartilage using a fibril-reinforced model, which has been successfully used to account for the load response of the relaxation tests of articular cartilage. Experiments were performed on bovine articular cartilage disks (n=8) using multi-step loading protocols, involving both creep and relaxation in each protocol. The experimental results indicated that mechanical changes, such as fiber recruitment in collagen network during stretch, recovered fully upon unloading. Creep loading did not affect relaxation properties, and vice versa. Relaxation proceeded much faster than creep, because of different fluid pressure profiles. The load sharing among the proteoglycan matrix, collagen network and fluid pressurization was predicted to differ for the creep and relaxation testing. The experimentally observed strong creep and relaxation responses in unconfined compression could not be predicted if either fibril reinforcement or fluid pressurization were neglected. It was essential to consider the interplay between nonlinear fibril reinforcement and fluid pressurization for the transient response (this interplay may be best termed as fluid pressure driven fibril reinforcement). Fibril reinforcement played a relatively insignificant role in the compressive load response at equilibrium, in agreement with previous findings for cartilage stress relaxation testing.
Collapse
Affiliation(s)
- L P Li
- Roger Jackson Centre for Health and Wellness Research, Faculty of Kinesiology, University of Calgary, 2500 University Drive, N.W. Calgary, Alberta, Canada T2N 1N4.
| | | | | | | | | |
Collapse
|
42
|
|
43
|
Abstract
An important and longstanding field of research in orthopedic biomechanics is the elucidation and mathematical modeling of the mechanical response of cartilaginous tissues. Traditional approaches have treated such tissues as continua and have described their mechanical response in terms of macroscopic models borrowed from solid mechanics. The most important of such models are the biphasic and single-phase viscoelastic models, and the many variations thereof. These models have reached a high level of maturity and have been successful in describing a wide range of phenomena. An alternative approach that has received considerable recent interest, both in orthopedic biomechanics and in other fields, is the description of mechanical response based on consideration of a tissue's structure—so-called microstructural modeling. Examples of microstructurally based approaches include fibril-reinforced biphasic models and homogenization approaches. A review of both macroscopic and microstructural constitutive models is given in the present work.
Collapse
Affiliation(s)
- Zeike A Taylor
- Intelligent Systems for Medicine Laboratgory, School of Mechanical Engineering, University of Western Australia, Crawley/Perth WA, Australia
| | | |
Collapse
|
44
|
Shirazi R, Shirazi-Adl A. Analysis of articular cartilage as a composite using nonlinear membrane elements for collagen fibrils. Med Eng Phys 2005; 27:827-35. [PMID: 16002317 DOI: 10.1016/j.medengphy.2005.04.024] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2004] [Revised: 03/29/2005] [Accepted: 04/07/2005] [Indexed: 11/16/2022]
Abstract
To develop a composite fibre-reinforced model of the cartilage, membrane shell elements were introduced to represent collagen fibrils reinforcing the isotropic porous solid matrix filled with fluid. Nonlinear stress-strain curve of pure collagen fibres and collagen volume fraction were explicitly presented in the formulation of these membrane elements. In this composite model, in accordance with tissue structure, the matrix and fibril membrane network experienced dissimilar stresses despite identical strains in the fibre directions. Different unconfined compression and indentation case studies were performed to determine the distinct role of membrane collagen fibrils in nonlinear poroelastic mechanics of articular cartilage. The importance of nonlinear fibril membrane elements in the tissue relaxation response as well as in temporal and spatial variations of pore pressure and solid matrix stresses was demonstrated. By individual adjustments of the collagen volume fraction and collagen mechanical properties, the model allows for the simulation of alterations in the fibril network structure of the tissue towards modelling damage processes or repair attempts. The current model, which is based on a physiological description of the tissue structure, is promising in improvement of our understanding of the cartilage pathomechanics.
Collapse
Affiliation(s)
- R Shirazi
- Division of Applied Mechanics, Department of Mechanical Engineering, Ecole Polytechnique, P.O. Box 6079, Station "centre-ville", Montréal, Que., Canada H3C 3A7
| | | |
Collapse
|
45
|
Tran-Khanh N, Hoemann CD, McKee MD, Henderson JE, Buschmann MD. Aged bovine chondrocytes display a diminished capacity to produce a collagen-rich, mechanically functional cartilage extracellular matrix. J Orthop Res 2005; 23:1354-62. [PMID: 16048738 DOI: 10.1016/j.orthres.2005.05.009.1100230617] [Citation(s) in RCA: 93] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2005] [Revised: 05/10/2005] [Accepted: 05/25/2005] [Indexed: 02/04/2023]
Abstract
Most fundamental studies in cartilage tissue engineering investigate the ability of chondrocytes from young animals to produce cartilaginous matrix under various conditions, while current clinical applications such as autologous chondrocyte implantation, use chondrocytes from donors that are decades past skeletal maturity. Previous investigations have suggested that several characteristics of primary chondrocytes are age-dependent but none have quantified cell proliferation, proteoglycan synthesis and accumulation, collagen synthesis and accumulation, compressive and tensile mechanical properties in order to examine the effects of donor age on all of these parameters. We enzymatically isolated primary bovine chondrocytes from fetal, young and aged animals and cultured these cells in agarose gels to assess the above-mentioned properties. We found that fetal and young (but still skeletally mature i.e. 18-month-old bovine) chondrocytes behaved similarly, while aged chondrocytes (5- to 7-year-old bovine) displayed diminished proliferation ( approximately 2x less), a slightly reduced proteoglycan accumulation per cell ( approximately 20%), and significantly less collagen accumulation per cell ( approximately 55%) compared to the younger cells. Histological observations and mechanical properties supported these findings, where a particularly significant reduction in tensile stiffness produced by aged chondrocytes compared to younger cells was observed. Our findings suggest that donor age is an important factor in determining the outcome and potential success when tissue-engineered cartilage is produced from articular chondrocytes. More specifically, primary chondrocytes from aged donors may not possess sufficient capacity to produce the extracellular matrix that is required for a mechanically resilient tissue.
Collapse
Affiliation(s)
- Nicolas Tran-Khanh
- Institute of Biomedical Engineering, Ecole Polytechnique, Montreal, Quebec, Canada
| | | | | | | | | |
Collapse
|
46
|
Huang CY, Stankiewicz A, Ateshian GA, Mow VC. Anisotropy, inhomogeneity, and tension-compression nonlinearity of human glenohumeral cartilage in finite deformation. J Biomech 2005; 38:799-809. [PMID: 15713301 PMCID: PMC3786419 DOI: 10.1016/j.jbiomech.2004.05.006] [Citation(s) in RCA: 152] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/07/2004] [Indexed: 11/21/2022]
Abstract
The tensile and compressive properties of human glenohumeral cartilage were determined by testing 120 rectangular strips in uniaxial tension and 70 cylindrical plugs in confined compression, obtained from five human glenohumeral joints. Specimens were harvested from five regions across the articular surface of the humeral head and two regions on the glenoid. Tensile strips were obtained along two orientations, parallel and perpendicular to the split-line directions. Two serial slices through the thickness, corresponding to the superficial and middle zones of the cartilage layers, were prepared from each tensile strip and each compressive plug. The equilibrium tensile modulus and compressive aggregate modulus of cartilage were determined from the uniaxial tensile and confined compression tests, respectively. Significant differences in the tensile moduli were found with depth and orientation relative to the local split-line direction. Articular cartilage of the humeral head was significantly stiffer in tension than that of the glenoid. There were significant differences in the aggregate compressive moduli of articular cartilage between superficial and middle zones in the humeral head. Furthermore, tensile and compressive stress-strain responses exhibited nonlinearity under finite strain, while the tensile modulus differed by up to two orders of magnitude from the compressive aggregate modulus at 0% strain, demonstrating a high degree of tension-compression nonlinearity. The complexity of the mechanical properties of human glenohumeral cartilage was exposed in this study, showing anisotropy, inhomogeneity, and tension-compression nonlinearity within the same joint. The observed differences in the tensile properties of human glenohumeral cartilage suggest that the glenoid may be more susceptible to cartilage degeneration than the humeral head.
Collapse
Affiliation(s)
- Chun-Yuh Huang
- Department of Mechanical Engineering Columbia University, SW Mudd, Mail Code 4703, 500 West 120th Street, New York, NY 10027, USA
| | | | | | | |
Collapse
|
47
|
Hoemann CD, Sun J, Légaré A, McKee MD, Buschmann MD. Tissue engineering of cartilage using an injectable and adhesive chitosan-based cell-delivery vehicle. Osteoarthritis Cartilage 2005; 13:318-29. [PMID: 15780645 DOI: 10.1016/j.joca.2004.12.001] [Citation(s) in RCA: 230] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2004] [Accepted: 12/11/2004] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Adult articular cartilage shows a limited intrinsic repair response to traumatic injury. To regenerate damaged cartilage, cell-assisted repair is thus viewed as a promising therapy, despite being limited by the lack of a suitable technique to deliver and retain chondrogenic cells at the defect site. DESIGN We have developed a cytocompatible chitosan solution that is space-filling, gels within minutes, and adheres to cartilage and bone in situ. This unique combination of properties suggested significant potential for its use as an arthroscopically injectable vehicle for cell-assisted cartilage repair. The primary goal of this study was to assess the ability of this polymer system, when loaded with primary articular chondrocytes, to support cartilage formation in vitro and in vivo. The chitosan gel was cultured in vitro, with and without chondrocytes, as well as injected subcutaneously in nude mice to form subcutaneous dorsal implants. In vitro and in vivo constructs were collectively analyzed histologically, for chondrocyte mRNA and protein expression, for biochemical levels of glycosaminoglycan, collagen, and DNA, and for mechanical properties. RESULTS Resulting tissue constructs revealed histochemical, biochemical and mechanical properties comparable to those observed in vitro for primary chondrocytes cultured in 2% agarose. Moreover, the gel was retained after injection into a surgically prepared, rabbit full-thickness chondral defect after 1 day in vivo, and in rabbit osteochondral defects, up to 1 week. CONCLUSIONS The in situ-gelling chitosan solution described here can support in vitro and in vivo accumulation of cartilage matrix by primary chondrocytes, while persisting in osteochondral defects at least 1 week in vivo.
Collapse
Affiliation(s)
- C D Hoemann
- Biomedical and Chemical Engineering, Ecole Polytechnique, Montreal, QC, Canada.
| | | | | | | | | |
Collapse
|
48
|
Chahine NO, Wang CCB, Hung CT, Ateshian GA. Anisotropic strain-dependent material properties of bovine articular cartilage in the transitional range from tension to compression. J Biomech 2005; 37:1251-61. [PMID: 15212931 PMCID: PMC2819725 DOI: 10.1016/j.jbiomech.2003.12.008] [Citation(s) in RCA: 127] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/01/2003] [Indexed: 11/30/2022]
Abstract
Articular cartilage exhibits complex mechanical properties such as anisotropy, inhomogeneity and tension-compression nonlinearity. This study proposes and demonstrates that the application of compressive loading in the presence of osmotic swelling can be used to acquire a spectrum of incremental cartilage moduli (EYi) and Poisson's ratios (upsilon ij) from tension to compression. Furthermore, the anisotropy of the tissue can be characterized in both tension and compression by conducting these experiments along three mutually perpendicular loading directions: parallel to split-line (1-direction), perpendicular to split-line (2-direction) and along the depth direction (3-direction, perpendicular to articular surface), accounting for tissue inhomogeneity between the surface and deep layers in the latter direction. Tensile moduli were found to be strain-dependent while compressive moduli were nearly constant. The peak tensile (+) Young's moduli in 0.15M NaCl were E+Y1=3.1+/-2.3, E+Y2=1.3+/-0.3, E+Y3(Surface)=0.65+/-0.29 and E+Y3(Deep)=2.1+/-1.2 MPa. The corresponding compressive (-) Young's moduli were E-Y1=0.23+/-0.07, E-Y2=0.22+/-0.07, E-Y3(Surface)=0.18+/-0.07 and E-Y3(Deep)=0.35+/-0.11 MPa. Peak tensile Poisson's ratios were upsilon+12=0.22+/-0.06, upsilon+21=0.13+/-0.07, upsilon+31(Surface)=0.10+/-0.03 and upsilon+31(Deep)=0.20+/-0.05 while compressive Poisson's ratios were upsilon-12=0.027+/-0.012, upsilon-21=0.017+/-0.07, upsilon-31(Surface)=0.034+/-0.009 and upsilon-31(Deep)=0.065+/-0.024. Similar measurements were also performed at 0.015 M and 2 M NaCl, showing strong variations with ionic strength. Results indicate that (a) a smooth transition occurs in the stress-strain and modulus-strain responses between the tensile and compressive regimes, and (b) cartilage exhibits orthotropic symmetry within the framework of tension-compression nonlinearity. The strain-softening behavior of cartilage (the initial decrease in EYi with increasing compressive strain) can be interpreted in the context of osmotic swelling and tension-compression nonlinearity.
Collapse
Affiliation(s)
- Nadeen O. Chahine
- Musculoskeletal Biomechanics Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027
| | - Christopher C-B. Wang
- Cellular Engineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027
| | - Clark T. Hung
- Cellular Engineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027
| | - Gerard A. Ateshian
- Musculoskeletal Biomechanics Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027
| |
Collapse
|
49
|
Sun DD, Guo XE, Likhitpanichkul M, Lai WM, Mow VC. The influence of the fixed negative charges on mechanical and electrical behaviors of articular cartilage under unconfined compression. J Biomech Eng 2004; 126:6-16. [PMID: 15171124 DOI: 10.1115/1.1644562] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Unconfined compression test has been frequently used to study the mechanical behaviors of articular cartilage, both theoretically and experimentally. It has also been used in explant and gel-cell-complex studies in tissue engineering. In biphasic and poroelastic theories, the effect of charges fixed on the proteoglycan macromolecules in articular cartilage is embodied in the apparent compressive Young's modulus and the apparent Poisson's ratio of the tissue, and the fluid pressure is considered to be the portion above the osmotic pressure. In order to understand how proteoglycan fixed charges might affect the mechanical behaviors of articular cartilage, and in order to predict the osmotic pressure and electric fields inside the tissue in this experimental configuration, it is necessary to use a model that explicitly takes into account the charged nature of the tissue and the flow of ions within its porous interstices. In this paper, we used a finite element model based on the triphasic theory to study how fixed charges in the porous-permeable soft tissue can modulate its mechanical and electrochemical responses under a step displacement in unconfined compression. The results from finite element calculations showed that: 1) A charged tissue always supports a larger load than an uncharged tissue of the same intrinsic elastic moduli. 2) The apparent Young's modulus (the ratio of the equilibrium axial stress to the axial strain) is always greater than the intrinsic Young's modulus of an uncharged tissue. 3) The apparent Poisson's ratio (the negative ratio of the lateral strain to the axial strain) is always larger than the intrinsic Poisson's ratio of an uncharged tissue. 4) Load support derives from three sources: intrinsic matrix stiffness, hydraulic pressure and osmotic pressure. Under the unconfined compression, the Donnan osmotic pressure can constitute between 13%-22% of the total load support at equilibrium. 5) During the stress-relaxation process following the initial instant of loading, the diffusion potential (due to the gradient of the fixed charge density and the associated gradient of ion concentrations) and the streaming potential (due to fluid convection) compete against each other. Within the physiological range of material parameters, the polarity of the electric potential depends on both the mechanical properties and the fixed charge density (FCD) of the tissue. For softer tissues, the diffusion effects dominate the electromechanical response, while for stiffer tissues, the streaming potential dominates this response. 6) Fixed charges do not affect the instantaneous strain field relative to the initial equilibrium state. However, there is a sudden increase in the fluid pressure above the initial equilibrium osmotic pressure. These new findings are relevant and necessary for the understanding of cartilage mechanics, cartilage biosynthesis, electromechanical signal transduction by chondrocytes, and tissue engineering.
Collapse
Affiliation(s)
- D D Sun
- Orthopaedic Research Laboratory, Department of Biomedical Engineering, Orthopaedic Surgery and Mechanical Engineering, Columbia University, 630 West, 168th Street, BB1412, New York, NY 10032, USA
| | | | | | | | | |
Collapse
|
50
|
Chao PG, Tang Z, Angelini E, West AC, Costa KD, Hung CT. Dynamic osmotic loading of chondrocytes using a novel microfluidic device. J Biomech 2004; 38:1273-81. [PMID: 15863112 DOI: 10.1016/j.jbiomech.2004.06.016] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2003] [Revised: 06/14/2004] [Accepted: 06/21/2004] [Indexed: 10/26/2022]
Abstract
Many cells exhibit disparate responses to a mechanical stimulus depending on whether it is applied dynamically or statically. In this context, few studies have examined how cells respond to dynamic changes of the extracellular osmolality. In this study, we hypothesized that the cell size change response of cultured articular chondrocytes would be dependent on the frequency of applied osmotic loading. To test this hypothesis, we developed a novel microfluidic device, to apply hydrostatic pressure-driven dynamic osmotic loading by applying composition modulated flow, adapted from Tang and co-workers. This microfluidic device was used to study osmotic loads of +/-180 mOsm at a frequency up to 0.1 Hz with a constant minimal fluid-shear stress, and permit real-time monitoring of cell responses. Bovine articular chondrocytes were observed to exhibit increasing changes in cell volume with decreasing osmotic loading frequency. When the cell volume response was modeled by an exponential function, chondrocytes exhibited significantly different volume change responses to dynamic osmotic loading at 0.0125 Hz and static osmotic loading applied for a period of four minutes (Delta = +/-180 mOsm relative to the isotonic 360 mOsm). The intracellular calcium response at 0.0125 Hz was also monitored and compared with the response to static loading. Coupled with phenomenological or constitutive models, this novel approach could yield new information regarding cell material properties in response to dynamic loading that may contribute new insights into mechanisms of cellular homeostasis and mechanotransduction.
Collapse
Affiliation(s)
- P Grace Chao
- Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Avenue, New York, NY 10027, USA
| | | | | | | | | | | |
Collapse
|