Valtin J, Behrens S, Ruland A, Schmieder F, Sonntag F, Renner LD, Maitz MF, Werner C. A New In Vitro Blood Flow Model for the Realistic Evaluation of Antimicrobial Surfaces. Adv Healthc Mater 2023; 12:e2301300. [PMID: 37498721 DOI: 10.1002/adhm.202301300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 06/13/2023] [Indexed: 07/29/2023]
Abstract
Device-associated bloodstream infections can cause serious medical problems and cost-intensive postinfection management, defining a need for more effective antimicrobial coatings. Newly developed coatings often show reduced bacterial colonization and high hemocompatibility in established in vitro tests, but fail in animal studies or clinical trials. The poor predictive power of these models is attributed to inadequate representation of in vivo conditions. Herein, a new single-pass blood flow model, with simultaneous incubation of the test surface with bacteria and freshly-drawn human blood, is presented. The flow model is validated by comparative analysis of a recently developed set of antiadhesive and contact-killing polymer coatings, and the corresponding uncoated polycarbonate surfaces. The results confirm the model's ability to differentiate the antimicrobial activities of the studied surfaces. Blood activation data correlate with bacterial surface coverage: low bacterial adhesion is associated with low inflammation and hemostasis. Shear stress correlates inversely with bacterial colonization, especially on antiadhesive surfaces. The introduced model is concluded to enable the evaluation of novel antimicrobial materials under in vivo-like conditions, capturing interactions between bacteria and biomaterials surfaces in the presence of key components of the ex vivo host response.
Collapse
Affiliation(s)
- Juliane Valtin
- Leibniz Institute of Polymer Research Dresden, Institute of Biofunctional Polymer Materials, Hohe Strasse 6, 01069, Dresden, Germany
| | - Stephan Behrens
- Fraunhofer Institute for Material and Beam Technology IWS, 01277, Dresden, Germany
| | - André Ruland
- Leibniz Institute of Polymer Research Dresden, Institute of Biofunctional Polymer Materials, Hohe Strasse 6, 01069, Dresden, Germany
| | - Florian Schmieder
- Fraunhofer Institute for Material and Beam Technology IWS, 01277, Dresden, Germany
| | - Frank Sonntag
- Fraunhofer Institute for Material and Beam Technology IWS, 01277, Dresden, Germany
| | - Lars D Renner
- Leibniz Institute of Polymer Research Dresden, Institute of Biofunctional Polymer Materials, Hohe Strasse 6, 01069, Dresden, Germany
| | - Manfred F Maitz
- Leibniz Institute of Polymer Research Dresden, Institute of Biofunctional Polymer Materials, Hohe Strasse 6, 01069, Dresden, Germany
| | - Carsten Werner
- Leibniz Institute of Polymer Research Dresden, Institute of Biofunctional Polymer Materials, Hohe Strasse 6, 01069, Dresden, Germany
- Technische Universität Dresden, Cluster of Excellence Physics of Life, Center for Regenerative Therapies Dresden and Faculty of Chemistry and Food Chemistry, 01307, Dresden, Germany
| |
Collapse
|
2
|
Frisch E, Clavier L, Belhamdi A, Vrana NE, Lavalle P, Frisch B, Heurtault B, Gribova V. Preclinical in vitro evaluation of implantable materials: conventional approaches, new models and future directions. Front Bioeng Biotechnol 2023; 11:1193204. [PMID: 37576997 PMCID: PMC10416115 DOI: 10.3389/fbioe.2023.1193204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 07/12/2023] [Indexed: 08/15/2023] Open
Abstract
Nowadays, implants and prostheses are widely used to repair damaged tissues or to treat different diseases, but their use is associated with the risk of infection, inflammation and finally rejection. To address these issues, new antimicrobial and anti-inflammatory materials are being developed. Aforementioned materials require their thorough preclinical testing before clinical applications can be envisaged. Although many researchers are currently working on new in vitro tissues for drug screening and tissue replacement, in vitro models for evaluation of new biomaterials are just emerging and are extremely rare. In this context, there is an increased need for advanced in vitro models, which would best recapitulate the in vivo environment, limiting animal experimentation and adapted to the multitude of these materials. Here, we overview currently available preclinical methods and models for biological in vitro evaluation of new biomaterials. We describe several biological tests used in biocompatibility assessment, which is a primordial step in new material's development, and discuss existing challenges in this field. In the second part, the emphasis is made on the development of new 3D models and approaches for preclinical evaluation of biomaterials. The third part focuses on the main parameters to consider to achieve the optimal conditions for evaluating biocompatibility; we also overview differences in regulations across different geographical regions and regulatory systems. Finally, we discuss future directions for the development of innovative biomaterial-related assays: in silico models, dynamic testing models, complex multicellular and multiple organ systems, as well as patient-specific personalized testing approaches.
Collapse
Affiliation(s)
- Emilie Frisch
- Université de Strasbourg, CNRS UMR 7199, 3Bio Team, Laboratoire de Conception et Application de Molécules Bioactives, Faculté de Pharmacie, Strasbourg, France
| | - Lisa Clavier
- Institut National de la Santé et de la Recherche Médicale, Inserm UMR_S 1121 Biomaterials and Bioengineering, Centre de Recherche en Biomédecine de Strasbourg, Strasbourg, France
- Université de Strasbourg, Faculté de Chirurgie Dentaire, Strasbourg, France
| | | | | | - Philippe Lavalle
- Institut National de la Santé et de la Recherche Médicale, Inserm UMR_S 1121 Biomaterials and Bioengineering, Centre de Recherche en Biomédecine de Strasbourg, Strasbourg, France
- Université de Strasbourg, Faculté de Chirurgie Dentaire, Strasbourg, France
- SPARTHA Medical, Strasbourg, France
| | - Benoît Frisch
- Université de Strasbourg, CNRS UMR 7199, 3Bio Team, Laboratoire de Conception et Application de Molécules Bioactives, Faculté de Pharmacie, Strasbourg, France
| | - Béatrice Heurtault
- Université de Strasbourg, CNRS UMR 7199, 3Bio Team, Laboratoire de Conception et Application de Molécules Bioactives, Faculté de Pharmacie, Strasbourg, France
| | - Varvara Gribova
- Institut National de la Santé et de la Recherche Médicale, Inserm UMR_S 1121 Biomaterials and Bioengineering, Centre de Recherche en Biomédecine de Strasbourg, Strasbourg, France
- Université de Strasbourg, Faculté de Chirurgie Dentaire, Strasbourg, France
| |
Collapse
|
3
|
Palaniyappan K, S. M. N. Mydin RB, Widera D, Noordin SS, Harun NH, Wan Eddis Effendy WN, Hazan R, Sreekantan S. Double-edged sword of biofouling potentials associated with haemocompatibility behaviour: titania nanotube arrays for medical implant surface technology. BENI-SUEF UNIVERSITY JOURNAL OF BASIC AND APPLIED SCIENCES 2023. [DOI: 10.1186/s43088-023-00363-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023] Open
Abstract
Abstract
Background
Medical implant failures are frequently associated with limitations of the surface technology that lead to biofouling and haemocompatibility issues. Titania nanotube array technology could provide a solution for this existing limitation. The present study describes the biofouling potential using the simulated body fluid model according to ISO 23317-2007 and haemocompatibility profiles according to ISO 10993-4 guidelines. Further haemocompatibility profiles were also assessed by evaluating full blood count, coagulation assays, haemolytic rate, whole blood clotting factor, platelet profiles, and FESEM characterization.
Result
Titania nanotube array nanosurface was found to present with better apatite biofouling and hydrophilic potential compared to bare titanium foil. Furthermore, good compatibility behaviour was observed based on the haemocompatibility profiles where no signs of thrombogenesis and haemolysis risks were observed. Titania nanotube array reduced fibrinogen adsorption, red blood cell and platelet adhesion and activation, which could be associated with detrimental biofouling properties.
Conclusion
Titania nanotube array could possess a double-edged sword of biofouling potentials that resist detrimental biofouling properties associated with thrombogenesis and haemolysis risk. It also provides better apatite biofouling potential for improved tissue and osseointegration activities. Knowledge from this study provides a better understanding of medical implant surface technology.
Graphical Abstract
Collapse
|
4
|
Dittfeld C, Welzel C, König U, Jannasch A, Alexiou K, Blum E, Bronder S, Sperling C, Maitz MF, Tugtekin SM. Hemocompatibility tuning of an innovative glutaraldehyde-free preparation strategy using riboflavin/UV crosslinking and electron irradiation of bovine pericardium for cardiac substitutes. BIOMATERIALS ADVANCES 2023; 147:213328. [PMID: 36764200 DOI: 10.1016/j.bioadv.2023.213328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 01/17/2023] [Accepted: 02/01/2023] [Indexed: 02/09/2023]
Abstract
Hemocompatibility tuning was adopted to explore and refine an innovative, GA-free preparation strategy combining decellularization, riboflavin/UV crosslinking, and low-energy electron irradiation (SULEEI) procedure. A SULEEI-protocol was established to avoid GA-dependent deterioration that results in insufficient long-term aortic valve bioprosthesis durability. Final SULEEI-pericardium, intermediate steps and GA-fixed reference pericardium were exposed in vitro to fresh human whole blood to elucidate effects of preparation parameters on coagulation and inflammation activation and tissue histology. The riboflavin/UV crosslinking step showed to be less efficient in inactivating extracellular matrix (ECM) protein activity than the GA fixation, leading to tissue-factor mediated blood clotting. Intensifying the riboflavin/UV crosslinking with elevated riboflavin concentration and dextran caused an enhanced activation of the complement system. Yet activation processes induced by the previous protocol steps were quenched with the final electron beam treatment step. An optimized SULEEI protocol was developed using an intense and extended, trypsin-containing decellularization step to inactivate tissue factor and a dextran-free, low riboflavin, high UV crosslinking step. The innovative and improved GA-free SULEEI-preparation protocol results in low coagulant and low inflammatory bovine pericardium for surgical application.
Collapse
Affiliation(s)
- Claudia Dittfeld
- Department of Cardiac Surgery, Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Heart Centre Dresden, Germany.
| | - Cindy Welzel
- Department of Cardiac Surgery, Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Heart Centre Dresden, Germany
| | - Ulla König
- Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, Dresden, Germany
| | - Anett Jannasch
- Department of Cardiac Surgery, Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Heart Centre Dresden, Germany
| | - Konstantin Alexiou
- Department of Cardiac Surgery, Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Heart Centre Dresden, Germany
| | - Ekaterina Blum
- Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, Dresden, Germany
| | - Saskia Bronder
- Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, Dresden, Germany
| | - Claudia Sperling
- Leibniz-Institut für Polymerforschung Dresden e.V., Institute Biofunctional Polymer Materials, Dresden, Germany
| | - Manfred F Maitz
- Leibniz-Institut für Polymerforschung Dresden e.V., Institute Biofunctional Polymer Materials, Dresden, Germany
| | - Sems-Malte Tugtekin
- Department of Cardiac Surgery, Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Heart Centre Dresden, Germany
| |
Collapse
|
5
|
Fiqri M, Alhidayah, Nirmayanti, Athiyyah U, Layadi P, Angeleve Fadjar TG, Permana AD. Enhanced localization of cefazoline sodium in the ocular tissue using thermosensitive-mucoadhesive hydrogels: Formulation development, hemocompatibility and in vivo irritation studies. J Drug Deliv Sci Technol 2022. [DOI: 10.1016/j.jddst.2022.103763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
6
|
Kaesler A, Rudawski FL, Zander MO, Hesselmann F, Pinar I, Schmitz-Rode T, Arens J, Steinseifer U, Clauser JC. In-Vitro Visualization of Thrombus Growth in Artificial Lungs Using Real-Time X-Ray Imaging: A Feasibility Study. Cardiovasc Eng Technol 2021; 13:318-330. [PMID: 34532837 PMCID: PMC9114054 DOI: 10.1007/s13239-021-00579-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 09/03/2021] [Indexed: 01/10/2023]
Abstract
PURPOSE Extracorporeal membrane oxygenation has gained increasing attention in the treatment of patients with acute and chronic cardiopulmonary and respiratory failure. However, clotting within the oxygenators or other components of the extracorporeal circuit remains a major complication that necessitates at least a device exchange and bears risks of adverse events for the patients. In order to better predict thrombus growth within oxygenators, we present an approach for in-vitro visualization of thrombus growth using real-time X-ray imaging. METHODS An in-vitro test setup was developed using low-dose anticoagulated ovine blood and allowing for thrombus growth within 4 h. The setup was installed in a custom-made X-ray setup that uses phase-contrast for imaging, thus providing enhanced soft-tissue contrast, which improves the differentiation between blood and potential thrombus growth. During experimentation, blood samples were drawn for the analysis of blood count, activated partial thromboplastin time and activated clotting time. Additionally, pressure and flow data was monitored and a full 360° X-ray scan was performed every 15 min. RESULTS Thrombus formation indicated by a pressure drop and changing blood parameters was monitored in all three test devices. Red and white thrombi (higher/lower attenuation, respectively) were successfully segmented in one set of X-ray images. CONCLUSION We showed the feasibility of a new in-vitro method for real-time thrombus growth visualization by means of phase contrast X-ray imaging. In addition, with more blood parameters that are clinically relevant, this approach might contribute to improved oxygenator exchange protocols in the clinical routine.
Collapse
Affiliation(s)
- Andreas Kaesler
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany
| | - Freya Lilli Rudawski
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany
| | - Mark Oliver Zander
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany
| | - Felix Hesselmann
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany
| | - Isaac Pinar
- Monash Institute of Medical Engineering and Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, Australia
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany.,Chair of Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany.,Monash Institute of Medical Engineering and Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, Australia
| | - Johanna Charlotte Clauser
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany.
| |
Collapse
|
7
|
Kamenska T, Abrashev M, Georgieva M, Krasteva N. Impact of Polyethylene Glycol Functionalization of Graphene Oxide on Anticoagulation and Haemolytic Properties of Human Blood. MATERIALS (BASEL, SWITZERLAND) 2021; 14:4853. [PMID: 34500942 PMCID: PMC8432731 DOI: 10.3390/ma14174853] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 08/09/2021] [Accepted: 08/24/2021] [Indexed: 11/16/2022]
Abstract
Graphene oxide (GO) is one of the most explored nanomaterials in recent years. It has numerous biomedical applications as a nanomaterial including drug and gene delivery, contrast imaging, cancer treatment, etc. Since most of these applications need intravenous administration of graphene oxide and derivatives, the evaluation of their haemocompatibility is an essential preliminary step for any of the developed GO applications. Plentiful data show that functionalization of graphene oxide nanoparticles with polyethylene glycol (PEG) increases biocompatibility, thus allowing PEGylated GO to elicit less dramatic blood cell responses than their pristine counterparts. Therefore, in this work, we PEGylated graphene oxide nanoparticles and evaluated the effects of their PEGylation on the structure and function of human blood components, especially on the morphology and the haemolytic potential of red blood cells (RBCs). Further, we studied the effect of PEGylation on some blood coagulation factors, including plasma fibrinogen as well as on the activated partial thromboplastin (aPTT), prothrombin time (PT) and platelet aggregation. Our findings provide important information on the mechanisms through which PEGylation increases GO compatibility with human blood cells. These data are crucial for the molecular design and biomedical applications of PEGylated graphene oxide nanomaterials in the future.
Collapse
Affiliation(s)
- Trayana Kamenska
- Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, “Acad. Georgi Bonchev” Street Bl. 21, 1113 Sofia, Bulgaria;
| | - Miroslav Abrashev
- Faculty of Physics, Sofia University “St. Kliment Ohridski”, 5 James Bourchier Blvd., 1164 Sofia, Bulgaria;
| | - Milena Georgieva
- Institute of Molecular Biology “Acad. R. Tsanev”, Bulgarian Academy of Sciences, “Acad. Georgi Bonchev” Street Bl. 21, 1113 Sofia, Bulgaria;
| | - Natalia Krasteva
- Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, “Acad. Georgi Bonchev” Street Bl. 21, 1113 Sofia, Bulgaria;
| |
Collapse
|
8
|
Roka-Moiia Y, Li M, Ivich A, Muslmani S, Kern KB, Slepian MJ. Impella 5.5 Versus Centrimag: A Head-to-Head Comparison of Device Hemocompatibility. ASAIO J 2021; 66:1142-1151. [PMID: 33136602 PMCID: PMC7594535 DOI: 10.1097/mat.0000000000001283] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Despite growing use of mechanical circulatory support, limitations remain related to hemocompatibility. Here, we performed a head-to-head comparison of the hemocompatibility of a centrifugal cardiac assist system-the Centrimag, with that of the latest generation of an intravascular microaxial system-the Impella 5.5. Specifically, hemolysis, platelet activation, microparticle (MP) generation, and von Willebrand factor (vWF) degradation were evaluated for both devices. Freshly obtained porcine blood was recirculated within device propelled mock loops for 4 hours, and alteration of the hemocompatibility parameters was monitored over time. We found that the Impella 5.5 and Centrimag exhibited low levels of hemolysis, as indicated by minor increase in plasma free hemoglobin. Both devices did not induce platelet degranulation, as no alteration of β-thromboglobulin and P-selectin in plasma occurred, rather minor downregulation of platelet surface P-selectin was detected. Furthermore, blood exposure to shear stress via both Centrimag and Impella 5.5 resulted in a minor decrease of platelet count with associated ejection of procoagulant MPs, and a decrease of vWF functional activity (but not plasma level of vWF-antigen). Greater MP generation was observed with the Centrimag relative to the Impella 5.5. Thus, the Impella 5.5 despite having a lower profile and higher impeller rotational speed demonstrated good and equivalent hemocompatibility, in comparison with the predicate Centrimag, with the advantage of lower generation of MPs.
Collapse
Affiliation(s)
- Yana Roka-Moiia
- From the Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, Arizona
| | - Mengtang Li
- Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee
| | - Adriana Ivich
- Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee
| | - Sami Muslmani
- From the Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, Arizona
| | - Karl B. Kern
- From the Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, Arizona
| | - Marvin J. Slepian
- From the Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, Arizona
- Department of Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, Arizona
| |
Collapse
|
9
|
Wolf MF, Girdhar G, Anderson AA, Ubl SR, Thinamany S, Jeffers HN, DeRusha CE, Rodriguez‐Fernandez J, Hoffmann S, Strief CA. In vitro methodology for medical device material thrombogenicity assessments: A use condition and bioanalytical proof-of-concept approach. J Biomed Mater Res B Appl Biomater 2021; 109:358-376. [PMID: 32929881 PMCID: PMC7821245 DOI: 10.1002/jbm.b.34705] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 07/12/2020] [Accepted: 08/04/2020] [Indexed: 12/26/2022]
Abstract
Device manufacturers and regulatory agencies currently utilize expensive and often inconclusive in vivo vascular implant models to assess implant material thrombogenicity. We report an in vitro thrombogenicity assessment methodology where test materials (polyethylene, Elasthane™ 80A polyurethane, Pebax®), alongside positive (borosilicate glass) and negative (no material) controls, were exposed to fresh human blood, with attention to common blood-contact use conditions and the variables: material (M), material surface modification (SM) with heparin, model (Mo), time (T), blood donor (D), exposure ratio (ER; cm2 material/ml blood), heparin anticoagulation (H), and blood draw/fill technique (DT). Two models were used: (1) a gentle-agitation test tube model and (2) a pulsatile flow closed-loop model. Thrombogenicity measurements included thrombin generation (thrombin-antithrombin complex [TAT] and human prothrombin fragment F1.2), platelet activation (β-thromboglobulin), and platelet counts. We report that: (a) thrombogenicity was strongly dependent (p < .0001) on M, H, and T, and variably dependent (p < .0001 - > .05) on Mo, SM, and D (b) differences between positive control, test, and negative control materials became less pronounced as H increased from 0.6 to 2.0 U/ml, and (c) in vitro-to-in vivo case comparisons showed consistency in thrombogenicity rankings on materials classified to be of low, moderate, and high concern. In vitro methods using fresh human blood are therefore scientifically sound and cost effective compared to in vivo methods for screening intravascular materials and devices for thrombogenicity.
Collapse
|
10
|
Stančič B, Qvarfordt B, Berglund MM, Brenden N, Sydow Bäckman M, Fransson M, Nordling S, Magnusson PU. The blood endothelial cell chamber - An innovative system to study immune responses in drug development. Int Immunopharmacol 2020; 90:107237. [PMID: 33310662 DOI: 10.1016/j.intimp.2020.107237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 11/04/2020] [Accepted: 11/23/2020] [Indexed: 10/22/2022]
Abstract
The risk for adverse immune-mediated reactions, associated with the administration of certain immunotherapeutic agents, should be mitigated early. Infusion reactions to monoclonal antibodies and other biopharmaceuticals, known as cytokine release syndrome, can arise from the release of cytokines via the drug target cell, as well as the recruitment of immune effector cells. While several in vitro cytokine release assays have been proposed up to date, many of them lack important blood components, required for this response to occur. The blood endothelial cell chamber model is an in vitro assay, composed of freshly drawn human whole blood and cultured human primary endothelial cells. Herein, its potential to study the compatibility of immunotherapeutics with the human immune system was studied by evaluating three commercially available monoclonal antibodies and bacterial endotoxin lipopolysaccharide. We demonstrate that the anti-CD28 antibody TGN1412 displayed an adaptive cytokine release profile and a distinct IL-2 response, accompanied with increased CD3+ cell recruitment. Alemtuzumab exhibited a clear cytokine response with a mixed adaptive/innate source (IFNγ, TNFα and IL-6). Its immunosuppressive nature is observed in depleted CD3+ cells. Cetuximab, associated with low infusion reactions, showed a very low or absent stimulatory effect on proinflammatory cytokines. In contrast, bacterial endotoxin demonstrated a clear innate cytokine response, defined by TNFα, IL-6 and IL-1β release, accompanied with a strong recruitment of CD14+CD16+ cells. Therefore, the blood endothelial cell chamber model is presented as a valuable in vitro tool to investigate therapeutic monoclonal antibodies with respect to cytokine release and vascular immune cell recruitment.
Collapse
Affiliation(s)
- Brina Stančič
- Department of Immunology, Genetics and Pathology, Rudbeck Laboratory, Dag Hammarskjöldsväg 20, 751 85, Uppsala University, Uppsala, Sweden; Department of Molecular Biology, Universidad Autónoma de Madrid, and Department of Molecular Neuropathology, Center of Molecular Biology Severo Ochoa (UAM-CSIC), Nicolás Cabrera 1, 28049 Madrid, Spain
| | - Bodil Qvarfordt
- Department of Immunology, Genetics and Pathology, Rudbeck Laboratory, Dag Hammarskjöldsväg 20, 751 85, Uppsala University, Uppsala, Sweden
| | | | - Nina Brenden
- Swedish Orphan Biovitrum AB, Tomtebodavägen 23A, 112 76 Solna, Sweden
| | | | - Moa Fransson
- Department of Immunology, Genetics and Pathology, Rudbeck Laboratory, Dag Hammarskjöldsväg 20, 751 85, Uppsala University, Uppsala, Sweden
| | - Sofia Nordling
- Department of Immunology, Genetics and Pathology, Rudbeck Laboratory, Dag Hammarskjöldsväg 20, 751 85, Uppsala University, Uppsala, Sweden
| | - Peetra U Magnusson
- Department of Immunology, Genetics and Pathology, Rudbeck Laboratory, Dag Hammarskjöldsväg 20, 751 85, Uppsala University, Uppsala, Sweden.
| |
Collapse
|
11
|
In vitro hemocompatibility testing of medical devices. Thromb Res 2020; 195:146-150. [DOI: 10.1016/j.thromres.2020.07.027] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Revised: 06/18/2020] [Accepted: 07/10/2020] [Indexed: 12/14/2022]
|
12
|
Pacharra S, McMahon S, Duffy P, Basnett P, Yu W, Seisel S, Stervbo U, Babel N, Roy I, Viebahn R, Wang W, Salber J. Cytocompatibility Evaluation of a Novel Series of PEG-Functionalized Lactide-Caprolactone Copolymer Biomaterials for Cardiovascular Applications. Front Bioeng Biotechnol 2020; 8:991. [PMID: 32903548 PMCID: PMC7438451 DOI: 10.3389/fbioe.2020.00991] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 07/29/2020] [Indexed: 11/24/2022] Open
Abstract
Although the use of bioresorbable materials in stent production is thought to improve long-term safety compared to their durable counterparts, a recent FDA report on the 2-year follow-up of the first FDA-approved bioresorbable vascular stent showed an increased occurrence of major adverse cardiac events and thrombosis in comparison to the metallic control. In order to overcome the issues of first generation bioresorbable polymers, a series of polyethylene glycol-functionalized poly-L-lactide-co-ε-caprolactone copolymers with varying lactide-to-caprolactone content is developed using a novel one-step PEG-functionalization and copolymerization strategy. This approach represents a new facile way toward surface enhancement for cellular interaction, which is shown by screening these materials regarding their cyto- and hemocompatibility in terms of cytotoxicity, hemolysis, platelet adhesion, leucocyte activation and endothelial cell adhesion. By varying the lactide-to-caprolactone polymer composition, it is possible to gradually affect endothelial and platelet adhesion which allows fine-tuning of the biological response based on polymer chemistry. All polymers developed were non-cytotoxic, had acceptable leucocyte activation levels and presented non-hemolytic (<2% hemolysis rate) behavior except for PLCL-PEG 55:45 which presented hemolysis rate of 2.5% ± 0.5. Water contact angles were reduced in the polymers containing PEG functionalization (PLLA-PEG: 69.8° ± 2.3, PCL-PEG: 61.2° ± 7.5) versus those without (PLLA: 79.5° ± 3.2, PCL: 76.4° ± 10.2) while the materials PCL-PEG550, PLCL-PEG550 90:10 and PLCL-PEG550 70:30 demonstrated best endothelial cell adhesion. PLLA-PEG550 and PLCL-PEG550 70:30 presented as best candidates for cardiovascular implant use from a cytocompatibility perspective across the spectrum of testing completed. Altogether, these polymers are excellent innovative materials suited for an application in stent manufacture due to the ease in translation of this one-step synthesis strategy to device production and their excellent in vitro cyto- and hemocompatibility.
Collapse
Affiliation(s)
- Sandra Pacharra
- Salber Laboratory, Centre for Clinical Research, Department of Experimental Surgery, Ruhr-Universität Bochum, Bochum, Germany
| | - Seán McMahon
- Laboratory A, Synergy Centre, Ashland Specialties Ireland Ltd., Dublin, Ireland
| | - Patrick Duffy
- Laboratory A, Synergy Centre, Ashland Specialties Ireland Ltd., Dublin, Ireland
| | - Pooja Basnett
- School of Life Sciences, College of Liberal Arts and Sciences, University of Westminster, London, United Kingdom
| | - Wenfa Yu
- Rosenhahn Group, Faculty of Chemistry and Biochemistry, Analytical Chemistry - Biointerfaces, Ruhr-Universität Bochum, Bochum, Germany
| | - Sabine Seisel
- Faculty of Chemistry and Biochemistry, Analytical Chemistry - Center for Electrochemical Sciences, Ruhr-Universität Bochum, Bochum, Germany
| | - Ulrik Stervbo
- Centre for Translational Medicine, Medical Department I, Marien Hospital Herne, University Hospital of the Ruhr-University Bochum, Herne, Germany
| | - Nina Babel
- Centre for Translational Medicine, Medical Department I, Marien Hospital Herne, University Hospital of the Ruhr-University Bochum, Herne, Germany
| | - Ipsita Roy
- Roy Group, Kroto Innovation Centre, Department of Materials Science and Engineering, University of Sheffield, Sheffield, United Kingdom
| | - Richard Viebahn
- Department of Surgery, Universitätsklinikum Knappschaftskrankenhaus Bochum GmbH, Bochum, Germany
| | - Wenxin Wang
- The Charles Institute of Dermatology, School of Medicine and Medical Science, University College Dublin, Dublin, Ireland
| | - Jochen Salber
- Salber Laboratory, Centre for Clinical Research, Department of Experimental Surgery, Ruhr-Universität Bochum, Bochum, Germany.,Department of Surgery, Universitätsklinikum Knappschaftskrankenhaus Bochum GmbH, Bochum, Germany
| |
Collapse
|
13
|
González I, Andrés RR, Pinto A, Carreras P. Influence of Hydrodynamics and Hematocrit on Ultrasound-Induced Blood Plasmapheresis. MICROMACHINES 2020; 11:E751. [PMID: 32751982 PMCID: PMC7463700 DOI: 10.3390/mi11080751] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 07/17/2020] [Accepted: 07/29/2020] [Indexed: 12/16/2022]
Abstract
Acoustophoretic blood plasma separation is based on cell enrichment processes driven by acoustic radiation forces. The combined influence of hematocrit and hydrodynamics has not yet been quantified in the literature for these processes acoustically induced on blood. In this paper, we present an experimental study of blood samples exposed to ultrasonic standing waves at different hematocrit percentages and hydrodynamic conditions, in order to enlighten their individual influence on the acoustic response of the samples. The experiments were performed in a glass capillary (700 µm-square cross section) actuated by a piezoelectric ceramic at a frequency of 1.153 MHz, hosting 2D orthogonal half-wavelength resonances transverse to the channel length, with a single-pressure-node along its central axis. Different hematocrit percentages Hct = 2.25%, 4.50%, 9.00%, and 22.50%, were tested at eight flow rate conditions of Q = 0:80 µL/min. Cells were collected along the central axis driven by the acoustic radiation force, releasing plasma progressively free of cells. The study shows an optimal performance in a flow rate interval between 20 and 80 µL/min for low hematocrit percentages Hct ≤ 9.0%, which required very short times close to 10 s to achieve cell-free plasma in percentages over 90%. This study opens new lines for low-cost personalized blood diagnosis.
Collapse
Affiliation(s)
- Itziar González
- Group of Ultrasonic Resonators RESULT, ITEFI, National Research Council of Spain CSIC 1, 28006 Madrid, Spain; (R.R.A.); (A.P.); (P.C.)
| | | | | | | |
Collapse
|
14
|
Vuković B, Milić M, Dobrošević B, Milić M, Ilić K, Pavičić I, Šerić V, Vrček IV. Surface Stabilization Affects Toxicity of Silver Nanoparticles in Human Peripheral Blood Mononuclear Cells. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E1390. [PMID: 32708883 PMCID: PMC7407574 DOI: 10.3390/nano10071390] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 07/13/2020] [Accepted: 07/14/2020] [Indexed: 02/06/2023]
Abstract
Silver nanoparticles (AgNPs) are one of the most investigated metal-based nanomaterials. Their biocidal activity boosted their application in both diagnostic and therapeutic medical systems. It is therefore crucial to provide sound evidences for human-related safety of AgNPs. This study aimed to enhance scientific knowledge with regard to biomedical safety of AgNPs by investigating how their different surface properties affect human immune system. METHODS preparation, characterization and stability evaluation was performed for four differently coated AgNPs encompassing neutral, positive and negative agents used for their surface stabilization. Safety aspects were evaluated by testing interaction of AgNPs with fresh human peripheral blood mononuclear cells (hPBMC) by means of particle cellular uptake and their ability to trigger cell death, apoptosis and DNA damages through induction of oxidative stress and damages of mitochondrial membrane. RESULTS all tested AgNPs altered morphology of freshly isolated hPBMC inducing apoptosis and cell death in a dose- and time-dependent manner. Highest toxicity was observed for positively-charged and protein-coated AgNPs. Cellular uptake of AgNPs was also dose-dependently increased and highest for positively charged AgNPs. Intracellularly, AgNPs induced production of reactive oxygen species (ROS) and damaged mitochondrial membrane. Depending on the dose, all AgNPs exhibited genotoxic potential. CONCLUSIONS this study provides systematic and comprehensive data showing how differently functionalized AgNPs may affect the human immune system. Presented results are a valuable scientific contribution to safety assessment of nanosilver-based blood-contacting medical products.
Collapse
Affiliation(s)
- Barbara Vuković
- Department of Clinical Laboratory Diagnostics, University Hospital Osijek, Josipa Huttlera 4, 31000 Osijek, Croatia; (B.V.); (M.M.); (B.D.); (V.Š.)
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, Josipa Huttlera 4, 31000 Osijek, Croatia
| | - Marija Milić
- Department of Clinical Laboratory Diagnostics, University Hospital Osijek, Josipa Huttlera 4, 31000 Osijek, Croatia; (B.V.); (M.M.); (B.D.); (V.Š.)
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, Josipa Huttlera 4, 31000 Osijek, Croatia
| | - Blaženka Dobrošević
- Department of Clinical Laboratory Diagnostics, University Hospital Osijek, Josipa Huttlera 4, 31000 Osijek, Croatia; (B.V.); (M.M.); (B.D.); (V.Š.)
| | - Mirta Milić
- Institute for Medical Research and Occupational Health, Ksaverska cesta 2, 10000 Zagreb, Croatia; (M.M.); (K.I.); (I.P.)
| | - Krunoslav Ilić
- Institute for Medical Research and Occupational Health, Ksaverska cesta 2, 10000 Zagreb, Croatia; (M.M.); (K.I.); (I.P.)
| | - Ivan Pavičić
- Institute for Medical Research and Occupational Health, Ksaverska cesta 2, 10000 Zagreb, Croatia; (M.M.); (K.I.); (I.P.)
| | - Vatroslav Šerić
- Department of Clinical Laboratory Diagnostics, University Hospital Osijek, Josipa Huttlera 4, 31000 Osijek, Croatia; (B.V.); (M.M.); (B.D.); (V.Š.)
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, Josipa Huttlera 4, 31000 Osijek, Croatia
| | - Ivana Vinković Vrček
- Institute for Medical Research and Occupational Health, Ksaverska cesta 2, 10000 Zagreb, Croatia; (M.M.); (K.I.); (I.P.)
| |
Collapse
|
15
|
|
16
|
Braune S, Latour RA, Reinthaler M, Landmesser U, Lendlein A, Jung F. In Vitro Thrombogenicity Testing of Biomaterials. Adv Healthc Mater 2019; 8:e1900527. [PMID: 31612646 DOI: 10.1002/adhm.201900527] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 08/15/2019] [Indexed: 12/29/2022]
Abstract
The short- and long-term thrombogenicity of implant materials is still unpredictable, which is a significant challenge for the treatment of cardiovascular diseases. A knowledge-based approach for implementing biofunctions in materials requires a detailed understanding of the medical device in the biological system. In particular, the interplay between material and blood components/cells as well as standardized and commonly acknowledged in vitro test methods allowing a reproducible categorization of the material thrombogenicity requires further attention. Here, the status of in vitro thrombogenicity testing methods for biomaterials is reviewed, particularly taking in view the preparation of test materials and references, the selection and characterization of donors and blood samples, the prerequisites for reproducible approaches and applied test systems. Recent joint approaches in finding common standards for a reproducible testing are summarized and perspectives for a more disease oriented in vitro thrombogenicity testing are discussed.
Collapse
Affiliation(s)
- Steffen Braune
- Institute of Biomaterial Science and Berlin‐Brandenburg Centre for Regenerative Therapies (BCRT)Helmholtz‐Zentrum Geesthacht Kantstrasse 55 14513 Teltow Germany
| | - Robert A. Latour
- Rhodes Engineering Research CenterDepartment of BioengineeringClemson University Clemson SC 29634 USA
| | - Markus Reinthaler
- Institute of Biomaterial Science and Berlin‐Brandenburg Centre for Regenerative Therapies (BCRT)Helmholtz‐Zentrum Geesthacht Kantstrasse 55 14513 Teltow Germany
- Department for CardiologyCharité UniversitätsmedizinCampus Benjamin Franklin Hindenburgdamm 30 12203 Berlin Germany
| | - Ulf Landmesser
- Department for CardiologyCharité UniversitätsmedizinCampus Benjamin Franklin Hindenburgdamm 30 12203 Berlin Germany
| | - Andreas Lendlein
- Institute of Biomaterial Science and Berlin‐Brandenburg Centre for Regenerative Therapies (BCRT)Helmholtz‐Zentrum Geesthacht Kantstrasse 55 14513 Teltow Germany
- Institute of ChemistryUniversity of Potsdam Karl‐Liebknecht‐Strasse 24‐25 14476 Potsdam Germany
- Helmholtz Virtual Institute “Multifunctional Biomaterials for Medicine”Helmholtz‐Zentrum Geesthacht Kantstrasse 55 14513 Teltow Germany
| | - Friedrich Jung
- Institute of Biomaterial Science and Berlin‐Brandenburg Centre for Regenerative Therapies (BCRT)Helmholtz‐Zentrum Geesthacht Kantstrasse 55 14513 Teltow Germany
- Helmholtz Virtual Institute “Multifunctional Biomaterials for Medicine”Helmholtz‐Zentrum Geesthacht Kantstrasse 55 14513 Teltow Germany
| |
Collapse
|
17
|
Sarode DN, Roy S. In Vitro models for thrombogenicity testing of blood-recirculating medical devices. Expert Rev Med Devices 2019; 16:603-616. [PMID: 31154869 DOI: 10.1080/17434440.2019.1627199] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
INTRODUCTION Blood-recirculating medical devices, such as mechanical circulatory support (MCS), extracorporeal membrane oxygenators (ECMO), and hemodialyzers, are commonly used to treat or improve quality of life in patients with cardiac, pulmonary, and renal failure, respectively. As part of their regulatory approval, guidelines for thrombosis evaluation in pre-clinical development have been established. In vitro testing evaluates a device's potential to produce thrombosis markers in static and dynamic flow loops. AREAS COVERED This review focuses on in vitro static and dynamic models to assess thrombosis in blood-recirculating medical devices. A summary of key devices is followed by a review of molecular markers of contact activation. Current thrombosis testing guidance documents, ISO 10993-4, ASTM F-2888, and F-2382 will be discussed, followed by analysis of their application to in vitro testing models. EXPERT OPINION In general, researchers have favored in vivo models to thoroughly evaluate thrombosis, limiting in vitro evaluation to hemolysis. In vitro studies are not standardized and it is often difficult to compare studies on similar devices. As blood-recirculating devices have advanced to include wearable and implantable artificial organs, expanded guidelines standardizing in vitro testing are needed to identify the thrombotic potential without excessive use of in vivo resources during pre-clinical development.
Collapse
Affiliation(s)
- Deepika N Sarode
- a Department of Bioengineering and Therapeutic Sciences , University of California , San Francisco , CA , USA
| | - Shuvo Roy
- a Department of Bioengineering and Therapeutic Sciences , University of California , San Francisco , CA , USA
| |
Collapse
|
18
|
Reinthaler M, Johansson JB, Braune S, Al-Hindwan HSA, Lendlein A, Jung F. Shear-induced platelet adherence and activation in an in-vitro dynamic multiwell-plate system. Clin Hemorheol Microcirc 2019; 71:183-191. [PMID: 30584128 DOI: 10.3233/ch-189410] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Circulating blood cells are prone to varying flow conditions when contacting cardiovascular devices. For a profound understanding of the complex interplay between the blood components/cells and cardiovascular implant surfaces, testing under varying shear conditions is required. Here, we study the influence of arterial and venous shear conditions on the in vitro evaluation of the thrombogenicity of polymer-based implant materials.Medical grade poly(dimethyl siloxane) (PDMS), polyethylene terephthalate (PET) and polytetrafluoroethylene (PTFE) films were included as reference materials. The polymers were exposed to whole blood from healthy humans. Blood was agitated orbitally at low (venous shear stress: 2.8 dyne · cm-2) and high (arterial shear stress: 22.2 dyne · cm-2) agitation speeds in a well-plate based test system. Numbers of non-adherent platelets, platelet activation (P-Selectin positive platelets), platelet function (PFA100 closure times) and platelet adhesion (laser scanning microscopy (LSM)) were determined.Microscopic data and counting of the circulating cells revealed increasing numbers of material-surface adherent platelets with increasing agitation speed. Also, activation of the platelets was substantially increased when tested under the high shear conditions (P-Selectin levels, PFA-100 closure times). At low agitation speed, the platelet densities did not differ between the three materials. Tested at the high agitation speed, lowest platelet densities were observed on PDMS, intermediate levels on PET and highest on PTFE. While activation of the circulating platelets was affected by the implant surfaces in a similar manner, PFA closure times did not reflect this trend.Differences in the thrombogenicity of the studied polymers were more pronounced when tested at high agitation speed due to the induced shear stresses. Testing under varying shear stresses, thus, led to a different evaluation of the implant thrombogenicity, which emphasizes the need for testing under various flow conditions. Our data further confirmed earlier findings where the same reference implants were tested under static (and not dynamic) conditions and with fresh human platelet rich plasma instead of whole blood. This supports that the application of common reference materials may improve inter-study comparisons, even under varying test conditions.
Collapse
Affiliation(s)
- Markus Reinthaler
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies Helmholtz-Zentrum Geesthacht, Teltow, Germany.,Department of Cardiology, Medical Clinic II, Charité University Medicine, Campus Benjamin Franklin, Berlin, Germany
| | - Johan Bäckemo Johansson
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies Helmholtz-Zentrum Geesthacht, Teltow, Germany
| | - Steffen Braune
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies Helmholtz-Zentrum Geesthacht, Teltow, Germany
| | - Haitham Saleh Ali Al-Hindwan
- Department of Cardiology, Medical Clinic II, Charité University Medicine, Campus Benjamin Franklin, Berlin, Germany
| | - Andreas Lendlein
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies Helmholtz-Zentrum Geesthacht, Teltow, Germany.,Institute of Chemistry, University of Potsdam, Potsdam, Germany
| | - Friedrich Jung
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies Helmholtz-Zentrum Geesthacht, Teltow, Germany
| |
Collapse
|
19
|
Zhao J, Bai L, Muhammad K, Ren XK, Guo J, Xia S, Zhang W, Feng Y. Construction of Hemocompatible and Histocompatible Surface by Grafting Antithrombotic Peptide ACH11 and Hydrophilic PEG. ACS Biomater Sci Eng 2019; 5:2846-2857. [DOI: 10.1021/acsbiomaterials.9b00431] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Jing Zhao
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, China
| | - Lingchuang Bai
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, China
| | - Khan Muhammad
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, China
| | - Xiang-kui Ren
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, China
| | - Jintang Guo
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, China
| | - Shihai Xia
- Department of Hepatopancreatobiliary and Splenic Medicine, Affiliated Hospital, Logistics University of People’s Armed Police Force, 220 Chenglin Road, Tianjin 300162, China
| | - Wencheng Zhang
- Department of Physiology and Pathophysiology, Logistics University of Chinese People’s Armed Police Force, Tianjin 300309, China
| | - Yakai Feng
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, China
- Key Laboratory of Systems Bioengineering (Ministry of Education), Tianjin University, Tianjin 300072, China
| |
Collapse
|
20
|
Innovative coating based on graphene and their decorated nanoparticles for medical stent applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 96:708-715. [DOI: 10.1016/j.msec.2018.11.084] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Revised: 11/16/2018] [Accepted: 11/29/2018] [Indexed: 12/29/2022]
|
21
|
Weidenbacher L, Müller E, Guex AG, Zündel M, Schweizer P, Marina V, Adlhart C, Vejsadová L, Pauer R, Spiecker E, Maniura-Weber K, Ferguson SJ, Rossi RM, Rottmar M, Fortunato G. In Vitro Endothelialization of Surface-Integrated Nanofiber Networks for Stretchable Blood Interfaces. ACS APPLIED MATERIALS & INTERFACES 2019; 11:5740-5751. [PMID: 30668107 DOI: 10.1021/acsami.8b18121] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Despite major technological advances within the field of cardiovascular engineering, the risk of thromboembolic events on artificial surfaces in contact with blood remains a major challenge and limits the functionality of ventricular assist devices (VADs) during mid- or long-term therapy. Here, a biomimetic blood-material interface is created via a nanofiber-based approach that promotes the endothelialization capability of elastic silicone surfaces for next-generation VADs under elevated hemodynamic loads. A blend fiber membrane made of elastic polyurethane and low-thrombogenic poly(vinylidene fluoride- co-hexafluoropropylene) was partially embedded into the surface of silicone films. These blend membranes resist fundamental irreversible deformation of the internal structure and are stably attached to the surface, while also exhibiting enhanced antithrombotic properties when compared to bare silicone. The composite material supports the formation of a stable monolayer of endothelial cells within a pulsatile flow bioreactor, resembling the physiological in vivo situation in a VAD. The nanofiber surface modification concept thus presents a promising approach for the future design of advanced elastic composite materials that are particularly interesting for applications in contact with blood.
Collapse
Affiliation(s)
| | | | | | | | - Peter Schweizer
- Department of Materials Science and Engineering, Institute of Micro- and Nanostructure Research & Center for Nanoanalysis and Electron Microscopy , Friedrich-Alexander-Universität Erlangen-Nürnberg , 91058 Erlangen , Germany
| | | | - Christian Adlhart
- Institute of Chemistry and Biotechnology , Zurich University of Applied Sciences ZHAW , 8820 Wädenswil , Switzerland
| | - Lucie Vejsadová
- Institute of Chemistry and Biotechnology , Zurich University of Applied Sciences ZHAW , 8820 Wädenswil , Switzerland
| | - Robin Pauer
- Electron Microscopy Center , Empa, Swiss Federal Laboratories for Materials Science and Technology , 8600 Dübendorf , Switzerland
| | - Erdmann Spiecker
- Department of Materials Science and Engineering, Institute of Micro- and Nanostructure Research & Center for Nanoanalysis and Electron Microscopy , Friedrich-Alexander-Universität Erlangen-Nürnberg , 91058 Erlangen , Germany
| | | | | | | | | | | |
Collapse
|
22
|
Blok SLJ, van Oeveren W, Engels GE. The optimal incubation time for in vitro hemocompatibility testing: Assessment using polymer reference materials under pulsatile flow with physiological wall shear stress conditions. J Biomed Mater Res B Appl Biomater 2019; 107:2335-2342. [PMID: 30697956 PMCID: PMC6767118 DOI: 10.1002/jbm.b.34326] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Revised: 12/08/2018] [Accepted: 01/05/2019] [Indexed: 12/19/2022]
Abstract
During hemocompatibility testing, activation products may reach plateau values which can result in less distinction between hemocompatible and hemo‐incompatible materials. Of concern is an underestimation of the blood activation caused by the biomaterial of interest, which may result in a false assessment of hemocompatibility. To elucidate the optimal incubation time for in vitro hemocompatibility testing, we used the Haemobile circulation model with human whole blood. Blood from healthy volunteers was in vitro incubated under pulsatile flow with physiological wall shear stress conditions at 37°C for 30, 60, 120, or 240 min. Test loops containing low‐density polyethylene and polydimethylsiloxane served as low and high reference materials, that is, hemocompatible and hemo‐incompatible biomaterials, respectively. In addition, empty loops served as a negative reference. Thrombogenicity, platelet function, inflammatory response, coagulation, and hemolysis between references and incubation times were compared. We found that thrombogenicity and platelet function were significantly affected by both the duration of incubation and the type of material. In particular, thrombogenicity and platelet function assessments were affected by incubation time. We found that an exposure time of 60 min was sufficient, and for almost all variables an optimal incubation time to discriminate between the low and high reference material. © 2019 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 2335–2342, 2019.
Collapse
Affiliation(s)
| | - Willem van Oeveren
- HaemoScan BV, 9723 JC, Groningen, The Netherlands.,Department of Cardiothoracic Surgery, University of Groningen, University Medical Center Groningen, 9713 GZ, Groningen, The Netherlands
| | - Gerwin Erik Engels
- HaemoScan BV, 9723 JC, Groningen, The Netherlands.,Department of Cardiothoracic Surgery, University of Groningen, University Medical Center Groningen, 9713 GZ, Groningen, The Netherlands
| |
Collapse
|
23
|
Mukhopadhyay S, Veroniaina H, Chimombe T, Han L, Zhenghong W, Xiaole Q. Synthesis and compatibility evaluation of versatile mesoporous silica nanoparticles with red blood cells: an overview. RSC Adv 2019; 9:35566-35578. [PMID: 35528069 PMCID: PMC9074774 DOI: 10.1039/c9ra06127d] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Accepted: 09/18/2019] [Indexed: 12/20/2022] Open
Abstract
Protean mesoporous silica nanoparticles are propitious candidates over decades for nanoscale drug delivery systems due to their unique characteristics, including changeable pore size, mesoporosity, high drug loading capacity and biodegradability.
Collapse
Affiliation(s)
- Subhankar Mukhopadhyay
- Key Laboratory of Modern Chinese Medicines
- China Pharmaceutical University
- Nanjing 210009
- PR China
| | | | - Tadious Chimombe
- Key Laboratory of Modern Chinese Medicines
- China Pharmaceutical University
- Nanjing 210009
- PR China
| | - Lidong Han
- Key Laboratory of Modern Chinese Medicines
- China Pharmaceutical University
- Nanjing 210009
- PR China
| | - Wu Zhenghong
- Key Laboratory of Modern Chinese Medicines
- China Pharmaceutical University
- Nanjing 210009
- PR China
| | - Qi Xiaole
- Key Laboratory of Modern Chinese Medicines
- China Pharmaceutical University
- Nanjing 210009
- PR China
| |
Collapse
|
24
|
Khalifehzadeh R, Ratner BD. Trifluoromethyl-functionalized poly(lactic acid): a fluoropolyester designed for blood contact applications. Biomater Sci 2019; 7:3764-3778. [DOI: 10.1039/c9bm00353c] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Fluorinated polymers are strong candidates for development of new cardiovascular medical devices, due to their lower thrombogenicity as compared to other polymers used for cardiovascular implants.
Collapse
Affiliation(s)
| | - Buddy D. Ratner
- Department of Chemical Engineering
- University of Washington
- Seattle
- USA
- Department of Bioengineering
| |
Collapse
|
25
|
Surface fluorination of polylactide as a path to improve platelet associated hemocompatibility. Acta Biomater 2018; 78:23-35. [PMID: 30036719 DOI: 10.1016/j.actbio.2018.07.042] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 07/18/2018] [Accepted: 07/19/2018] [Indexed: 12/11/2022]
Abstract
Surface-induced thrombosis is still a significant clinical concern for many types of blood-contacting medical devices. In particular, protein adsorption and platelet adhesion are important events due to their ability to trigger the coagulation cascade and initiate thrombosis. Poly(lactic acid) (PLA) has been the predominant polymer used for making bioresorbable stents. Despite long-term advantages, these stents are associated with higher rates of early thrombosis compared with permanent metallic stents. To address this issue, we modified the surface of PLA with a perfluoro compound facilitated by surface activation using radio frequency (RF) plasma. Fluoropolymers have been extensively used in blood contacting materials, such as blood vessel replacements due to their reduced thrombogenicity and reduced platelet reactivity. The compositions of plasma-treated surfaces were determined by electron spectroscopy for chemical analysis (ESCA). Also, contact angle measurements, cell cytotoxicity and the degradation profile of the treated polymers are presented. Finally, relevant blood compatibility parameters, including plasma protein adsorption, platelet adhesion and morphology, were evaluated. We hypothesized that tight binding of adsorbed albumin by fluoropolymers enhances its potential for blood-contacting applications. STATEMENT OF SIGNIFICANCE Although bioresorbable stents made from poly(lactic acid) (PLA) may have long-term clinical advantages, they have shown higher rates of early thrombosis as compared with permanent metallic stents. To improve the thromboresistance of PLA, we developed a novel method for surface fluorination of this polymer with a perfluoro compound. Fluoropolymers (e.g., expanded polytetrafluoroethylene) have long been used in blood-contacting applications due to their satisfactory clinical performance. This is the first report of PLA surface fluorination which might be applied to the fabrication of a new generation of fluorinated PLA stents with improved platelet interaction, tunable degradability and drug release capabilities. Also, we describe a general strategy for improving the platelet interactions with biomaterials based on albumin retention.
Collapse
|
26
|
Weber M, Steinle H, Golombek S, Hann L, Schlensak C, Wendel HP, Avci-Adali M. Blood-Contacting Biomaterials: In Vitro Evaluation of the Hemocompatibility. Front Bioeng Biotechnol 2018; 6:99. [PMID: 30062094 PMCID: PMC6054932 DOI: 10.3389/fbioe.2018.00099] [Citation(s) in RCA: 321] [Impact Index Per Article: 53.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Accepted: 06/26/2018] [Indexed: 12/15/2022] Open
Abstract
Hemocompatibility of blood-contacting biomaterials is one of the most important criteria for their successful in vivo applicability. Thus, extensive in vitro analyses according to ISO 10993-4 are required prior to clinical applications. In this review, we summarize essential aspects regarding the evaluation of the hemocompatibility of biomaterials and the required in vitro analyses for determining the blood compatibility. Static, agitated, or shear flow models are used to perform hemocompatibility studies. Before and after the incubation of the test material with fresh human blood, hemolysis, cell counts, and the activation of platelets, leukocytes, coagulation and complement system are analyzed. Furthermore, the surface of biomaterials are evaluated concerning attachment of blood cells, adsorption of proteins, and generation of thrombus and fibrin networks.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Meltem Avci-Adali
- Department of Thoracic and Cardiovascular Surgery, University Hospital Tübingen, Tübingen, Germany
| |
Collapse
|
27
|
Santos C, Turiel S, Sousa Gomes P, Costa E, Santos-Silva A, Quadros P, Duarte J, Battistuzzo S, Fernandes MH. Vascular biosafety of commercial hydroxyapatite particles: discrepancy between blood compatibility assays and endothelial cell behavior. J Nanobiotechnology 2018; 16:27. [PMID: 29566760 PMCID: PMC5863823 DOI: 10.1186/s12951-018-0357-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Accepted: 03/19/2018] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Vascular homeostasis is ensured by a dynamic interplay involving the endothelium, the platelets and the coagulation system. Thus, the vascular safety of particulate materials must address this integrated system, an approach that has been largely neglected. This work analysed the effects of commercial hydroxyapatite (HA) particles in blood compatibility and in endothelial cell behavior, due to their clinical relevance and scarcity of data on their vascular biosafety. RESULTS Particles with similar chemical composition and distinct size and morphology were tested, i.e. rod-like, nano dimensions and low aspect ratio (HAp1) and needle-shape with wider size and aspect ratio (HAp2). HAp1 and HAp2, at 1 to 10 mg/mL, did not affect haemolysis, platelet adhesion, aggregation and activation, or the coagulation system (intrinsic and extrinsic pathways), although HAp2 exhibited a slight thrombogenic potential at 10 mg/mL. Notwithstanding, significantly lower levels presented dose-dependent toxicity on endothelial cells' behavior. HAp1 and HAp2 decreased cell viability at levels ≥ 250 and ≥ 50 μg/mL, respectively. At 10 and 50 μg/mL, HAp1 did not interfere with the F-actin cytoskeleton, apoptotic index, cell cycle progression, expression of vWF, VECad and CD31, and the ability to form a network of tubular-like structures. Comparatively, HAp2 caused dose-dependent toxic effects in these parameters in the same concentration range. CONCLUSION The most relevant observation is the great discrepancy of HA particles' levels that interfere with the routine blood compatibility assays and the endothelial cell behavior. Further, this difference was also found to be dependent on the particles' size, morphology and aspect ratio, emphasizing the need of a complementary biological characterization, taking into consideration the endothelial cells' functionality, to establish the vascular safety of particulate HA.
Collapse
Affiliation(s)
- Catarina Santos
- EST Setúbal, DEM, Instituto Politécnico de Setúbal, Campus IPS, 2914-508, Setúbal, Portugal.,CQE, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001, Lisbon, Portugal
| | - Suzy Turiel
- Faculdade de Medicina Dentária, U. Porto, Rua Dr. Manuel Pereira da Silva, 4200-393, Porto, Portugal
| | - Pedro Sousa Gomes
- Faculdade de Medicina Dentária, U. Porto, Rua Dr. Manuel Pereira da Silva, 4200-393, Porto, Portugal.,REQUIMTE/LAQV - U. Porto, Porto, Portugal
| | - Elísio Costa
- UCIBIO/REQUIMTE, Departamento de Ciências Biológicas, Laboratório de Bioquímica, Faculdade de Farmácia, U. Porto (FFUP), Porto, Portugal
| | - Alice Santos-Silva
- UCIBIO/REQUIMTE, Departamento de Ciências Biológicas, Laboratório de Bioquímica, Faculdade de Farmácia, U. Porto (FFUP), Porto, Portugal
| | | | - José Duarte
- CIAFEL, Faculdade de Desporto, Universidade do Porto, Porto, Portugal
| | - Sílvia Battistuzzo
- Laboratório de Biologia Molecular e Genômica, Centro de Biociências, Universidade Federal do Rio Grande do Norte (UFRN), Campus Universitário s/n, Lagoa Nova, Natal, RN, 59072-970, Brazil
| | - Maria Helena Fernandes
- Faculdade de Medicina Dentária, U. Porto, Rua Dr. Manuel Pereira da Silva, 4200-393, Porto, Portugal. .,REQUIMTE/LAQV - U. Porto, Porto, Portugal.
| |
Collapse
|
28
|
Gaston E, Fraser JF, Xu ZP, Ta HT. Nano- and micro-materials in the treatment of internal bleeding and uncontrolled hemorrhage. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2017; 14:507-519. [PMID: 29162534 DOI: 10.1016/j.nano.2017.11.007] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2017] [Revised: 11/01/2017] [Accepted: 11/05/2017] [Indexed: 12/14/2022]
Abstract
Internal bleeding is defined as the loss of blood that occurs inside of a body cavity. After a traumatic injury, hemorrhage accounts for over 35% of pre-hospital deaths and 40% of deaths within the first 24 hours. Coagulopathy, a disorder in which the blood is not able to properly form clots, typically develops after traumatic injury and results in a higher rate of mortality. The current methods to treat internal bleeding and coagulopathy are inadequate due to the requirement of extensive medical equipment that is typically not available at the site of injury. To discover a potential route for future research, several current and novel treatment methods have been reviewed and analyzed. The aim of investigating different potential treatment options is to expand available knowledge, while also call attention to the importance of research in the field of treatment for internal bleeding and hemorrhage due to trauma.
Collapse
Affiliation(s)
- Elizabeth Gaston
- Australian Institute for Bioengineering and Nanotechnology, the University of Queensland, Brisbane, QLD, Australia; Department of Bioengineering, Clemson University, Clemson, SC, USA
| | - John F Fraser
- Faculty of Medicine, Critical Care Research Group, Prince Charles Hospital and the University of Queensland, Brisbane, Brisbane, QLD, Australia
| | - Zhi Ping Xu
- Australian Institute for Bioengineering and Nanotechnology, the University of Queensland, Brisbane, QLD, Australia
| | - Hang T Ta
- Australian Institute for Bioengineering and Nanotechnology, the University of Queensland, Brisbane, QLD, Australia.
| |
Collapse
|
29
|
Pedersen L, Birkemose E, Gils C, Safi S, Nybo M. Sample Type and Storage Conditions Affect Calprotectin Measurements in Blood. J Appl Lab Med 2017; 2:851-856. [PMID: 33636827 DOI: 10.1373/jalm.2017.024778] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Accepted: 09/18/2017] [Indexed: 11/06/2022]
Abstract
BACKGROUND Calprotectin, a complex of calcium-binding proteins, is abundant in granulocytes. Increased levels of plasma calprotectin have been found in patients with inflammatory and autoimmune diseases. However, a number of preanalytical factors may affect calprotectin measurement in blood samples. METHODS Twelve blood samples [4 tubes, 1 each of lithium-heparin (Li-heparin), EDTA, and serum] were drawn from each of 14 healthy individuals. To evaluate the effect of temperature and storage time in the lag time between collection and centrifugation, samples were kept for 2 h at 4 °C, 20 °C, or 37 °C, before centrifugation. Leukocyte, neutrophil, and monocyte counts were measured in EDTA samples on a Sysmex XN-10 hematology analyzer to investigate the relationship between calprotectin concentrations and the granulocyte count. RESULTS Calprotectin measurements in EDTA samples were not influenced by temperature or time lag between collection and analysis. Compared to EDTA plasma, significantly higher calprotectin concentrations were found in serum and Li-heparin plasma samples. Furthermore, calprotectin concentrations increased in serum and Li-heparin samples when stored at higher temperatures. There was a linear relationship between the serum calprotectin concentration and neutrophil count in EDTA whole blood. CONCLUSIONS EDTA is the most suitable anticoagulant for determination of calprotectin in plasma, as this sample matrix does not seem to be affected by temperature or time between sample collection and analysis. Of particular note, neutrophil activation by either clotting or centrifugation should be avoided during the preanalytical process.
Collapse
Affiliation(s)
- Lise Pedersen
- Department of Clinical Biochemistry, Holbæk Hospital, Holbæk, Denmark
| | - Erling Birkemose
- Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, Odense, Denmark
| | - Charlotte Gils
- Department of Clinical Immunology and Biochemistry, Lillebaelt Hospital, Vejle, Denmark
| | - Sara Safi
- Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, Odense, Denmark
| | - Mads Nybo
- Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, Odense, Denmark
| |
Collapse
|
30
|
Braune S, Latour RA, Lendlein A, Jung F. Comment on: "Hemocompatibility of Superhemophobic Titania Surfaces". Adv Healthc Mater 2017; 6. [PMID: 28692207 DOI: 10.1002/adhm.201700294] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Indexed: 12/24/2022]
Affiliation(s)
- Steffen Braune
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies (BCRT); Helmholtz-Zentrum Geesthacht; Kantstrasse 55 14513 Teltow Germany
| | - Robert A. Latour
- Rhodes Engineering Research Center; Department of Bioengineering; Clemson University; Clemson SC 29634 USA
| | - Andreas Lendlein
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies (BCRT); Helmholtz-Zentrum Geesthacht; Kantstrasse 55 14513 Teltow Germany
| | - Friedrich Jung
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies (BCRT); Helmholtz-Zentrum Geesthacht; Kantstrasse 55 14513 Teltow Germany
| |
Collapse
|
31
|
Fröhlich E. Hemocompatibility of inhaled environmental nanoparticles: Potential use of in vitro testing. JOURNAL OF HAZARDOUS MATERIALS 2017; 336:158-167. [PMID: 28494303 DOI: 10.1016/j.jhazmat.2017.04.041] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Revised: 03/09/2017] [Accepted: 04/14/2017] [Indexed: 06/07/2023]
Abstract
Hemocompatibility testing is an important part in the evaluation of nano-based medicines. However, it is not systematically used for the assessment of environmental particles since they do not come in contact with blood immediately. Studies on human exposure to air-borne particles and pulmonary exposure of rodents have reported alterations in blood physiology. It is not clear, whether these effects are majorly caused by tissue inflammation or translocated particles in blood. This review addresses the question, if in vitro hemocompatibility testing could help in the risk evaluation of inhaled particles. Particle blood concentrations were estimated based on exposure levels, ventilation volume, deposition rate, lung surface area, and permeability of the alveolar epithelium to particles. The categories of hemocompatibility, thrombosis, coagulation, platelets, hematology, and immunology, were introduced. Also, concentrations of ultrafine particles, silver nanoparticles, carbon nanotubes that caused adverse effects in human blood samples were compared to the estimated concentrations of translocated particles. The comparison suggested that, it is unlikely for translocated nanoparticles to be the sole cause of adverse blood effects. Nevertheless, the testing of specific hemocompatibility parameters (hemolysis and clotting) in healthy blood might help to compare biological effect of inhaled particles containing different amounts of contamination. Testing of samples from healthy and diseased persons might help to identify pathological dispositions that increase the possibility of adverse reaction of nanoparticles in blood.
Collapse
Affiliation(s)
- Eleonore Fröhlich
- Medical University of Graz, Center for Medical Research, Stiftingtalstr. 24, A-8010 Graz, Austria.
| |
Collapse
|
32
|
Braune S, Sperling C, Maitz MF, Steinseifer U, Clauser J, Hiebl B, Krajewski S, Wendel HP, Jung F. Evaluation of platelet adhesion and activation on polymers: Round-robin study to assess inter-center variability. Colloids Surf B Biointerfaces 2017; 158:416-422. [PMID: 28719863 DOI: 10.1016/j.colsurfb.2017.06.053] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Revised: 06/28/2017] [Accepted: 06/30/2017] [Indexed: 11/19/2022]
Abstract
The regulatory agencies provide recommendations rather than protocols or standard operation procedures for the hemocompatibility evaluation of novel materials e.g. for cardiovascular applications. Thus, there is a lack of specifications with regard to test setups and procedures. As a consequence, laboratories worldwide perform in vitro assays under substantially different test conditions, so that inter-laboratory and inter-study comparisons are impossible. Here, we report about a prospective, randomized and double-blind multicenter trial which demonstrates that standardization of in vitro test protocols allows a reproducible assessment of platelet adhesion and activation from fresh human platelet rich plasma as possible indicators of the thrombogenicity of cardiovascular implants. Standardization of the reported static in vitro setup resulted in a laboratory independent scoring of the following materials: poly(dimethyl siloxane) (PDMS), poly(ethylene terephthalate) (PET) and poly(tetrafluoro ethylene) (PTFE). The results of this in vitro study provide evidence that inter-laboratory and inter-study comparisons can be achieved for the evaluation of the adhesion and activation of platelets on blood-contacting biomaterials by stringent standardization of test protocols.
Collapse
Affiliation(s)
- S Braune
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies (BCRT), Helmholtz-Zentrum Geesthacht, Teltow, Germany
| | - C Sperling
- Max Bergmann Center of Biomaterials Dresden, Leibniz Institute of Polymer Research Dresden, Dresden, Germany
| | - M F Maitz
- Max Bergmann Center of Biomaterials Dresden, Leibniz Institute of Polymer Research Dresden, Dresden, Germany
| | - U Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering Helmholtz-Institute, RWTH Aachen University, Aachen, Germany
| | - J Clauser
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering Helmholtz-Institute, RWTH Aachen University, Aachen, Germany
| | - B Hiebl
- Institute for Animal Hygiene, Animal Welfare and Farm Animal Behaviour, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany
| | - S Krajewski
- Department of Thoracic and Cardiovascular Surgery, University Medical Center Tübingen, Tübingen, Germany
| | - H P Wendel
- Department of Thoracic and Cardiovascular Surgery, University Medical Center Tübingen, Tübingen, Germany
| | - F Jung
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies (BCRT), Helmholtz-Zentrum Geesthacht, Teltow, Germany.
| |
Collapse
|
33
|
Maria MS, Rakesh PE, Chandra TS, Sen AK. Capillary flow-driven microfluidic device with wettability gradient and sedimentation effects for blood plasma separation. Sci Rep 2017; 7:43457. [PMID: 28256564 PMCID: PMC5335260 DOI: 10.1038/srep43457] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Accepted: 01/24/2017] [Indexed: 12/12/2022] Open
Abstract
We report a capillary flow-driven microfluidic device for blood-plasma separation that comprises a cylindrical well between a pair of bottom and top channels. Exposure of the well to oxygen-plasma creates wettability gradient on its inner surface with its ends hydrophilic and middle portion hydrophobic. Due to capillary action, sample blood self-infuses into bottom channel and rises up the well. Separation of plasma occurs at the hydrophobic patch due to formation of a ‘self-built-in filter’ and sedimentation. Capillary velocity is predicted using a model and validated using experimental data. Sedimentation of RBCs is explained using modified Steinour’s model and correlation between settling velocity and liquid concentration is found. Variation of contact angle on inner surface of the well is characterized and effects of well diameter and height and dilution ratio on plasma separation rate are investigated. With a well of 1.0 mm diameter and 4.0 mm height, 2.0 μl of plasma was obtained (from <10 μl whole blood) in 15 min with a purification efficiency of 99.9%. Detection of glucose was demonstrated with the plasma obtained. Wetting property of channels was maintained by storing in DI water under vacuum and performance of the device was found to be unaffected over three weeks.
Collapse
Affiliation(s)
- M Sneha Maria
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai-600036, India.,Department of Biotechnology, Indian Institute of Technology Madras, Chennai-600036, India
| | - P E Rakesh
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai-600036, India
| | - T S Chandra
- Department of Biotechnology, Indian Institute of Technology Madras, Chennai-600036, India
| | - A K Sen
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai-600036, India
| |
Collapse
|
34
|
Toward a quantified, validated, and verifiable understanding of the Biointerface. Biointerphases 2016; 11:040201. [PMID: 28010113 DOI: 10.1116/1.4972550] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
35
|
In vitro blood flow model with physiological wall shear stress for hemocompatibility testing-An example of coronary stent testing. Biointerphases 2016; 11:031004. [PMID: 27435456 DOI: 10.1116/1.4958979] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Hemocompatibility of blood contacting medical devices has to be evaluated before their intended application. To assess hemocompatibility, blood flow models are often used and can either consist of in vivo animal models or in vitro blood flow models. Given the disadvantages of animal models, in vitro blood flow models are an attractive alternative. The in vitro blood flow models available nowadays mostly focus on generating continuous flow instead of generating a pulsatile flow with certain wall shear stress, which has shown to be more relevant in maintaining hemostasis. To address this issue, the authors introduce a blood flow model that is able to generate a pulsatile flow and wall shear stress resembling the physiological situation, which the authors have coined the "Haemobile." The authors have validated the model by performing Doppler flow measurements to calculate velocity profiles and (wall) shear stress profiles. As an example, the authors evaluated the thrombogenicity of two drug eluting stents, one that was already on the market and one that was still under development. After identifying proper conditions resembling the wall shear stress in coronary arteries, the authors compared the stents with each other and often used reference materials. These experiments resulted in high contrast between hemocompatible and incompatible materials, showing the exceptional testing capabilities of the Haemobile. In conclusion, the authors have developed an in vitro blood flow model which is capable of mimicking physiological conditions of blood flow as close as possible. The model is convenient in use and is able to clearly discriminate between hemocompatible and incompatible materials, making it suitable for evaluating the hemocompatible properties of medical devices.
Collapse
|
36
|
|