1
|
Song X, Guo Y, Chen C, Wang X. A silent two-photon imaging system for studying in vivo auditory neuronal functions. LIGHT, SCIENCE & APPLICATIONS 2022; 11:96. [PMID: 35422090 PMCID: PMC9010453 DOI: 10.1038/s41377-022-00783-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 03/28/2022] [Accepted: 03/30/2022] [Indexed: 05/04/2023]
Abstract
Two-photon laser-scanning microscopy has become an essential tool for imaging neuronal functions in vivo and has been applied to different parts of the neural system, including the auditory system. However, many components of a two-photon microscope, such as galvanometer-based laser scanners, generate mechanical vibrations and thus acoustic artifacts, making it difficult to interpret auditory responses from recorded neurons. Here, we report the development of a silent two-photon imaging system and its applications in the common marmoset (Callithrix Jacchus), a non-human primate species sharing a similar hearing range with humans. By utilizing an orthogonal pair of acousto-optical deflectors (AODs), full-frame raster scanning at video rate was achieved without introducing mechanical vibrations. Imaging depth can be optically controlled by adjusting the chirping speed on the AODs without any mechanical motion along the Z-axis. Furthermore, all other sound-generating components of the system were acoustically isolated, leaving the noise floor of the working system below the marmoset's hearing threshold. Imaging with the system in awake marmosets revealed many auditory cortex neurons that exhibited maximal responses at low sound levels, which were not possible to study using traditional two-photon imaging systems. This is the first demonstration of a silent two-photon imaging system that is capable of imaging auditory neuronal functions in vivo without acoustic artifacts. This capacity opens new opportunities for a better understanding of auditory functions in the brain and helps isolate animal behavior from microscope-generated acoustic interference.
Collapse
Affiliation(s)
- Xindong Song
- Laboratory of Auditory Neurophysiology, Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, 21205, USA.
| | - Yueqi Guo
- Laboratory of Auditory Neurophysiology, Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, 21205, USA
| | - Chenggang Chen
- Laboratory of Auditory Neurophysiology, Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, 21205, USA
| | - Xiaoqin Wang
- Laboratory of Auditory Neurophysiology, Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, 21205, USA.
| |
Collapse
|
2
|
Chang JC, Chang SY, Wu YC, Chang CY. Fast and direct optical dispersion estimation for ultrafast laser pulse compression. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:113702. [PMID: 34852563 DOI: 10.1063/5.0060564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Accepted: 10/21/2021] [Indexed: 06/13/2023]
Abstract
In ultrashort pulse laser applications, optical dispersion seriously affects the energy concentration in the laser pulse duration and lowers the peak power. Accordingly, this study proposes a rapid dispersion estimation mechanism to facilitate the compensation of optical dispersion using a closed-loop control system. In the proposed approach, the optical dispersion information of the laser pulse is estimated directly from a frequency-resolved optical gating trace without the need for an iterative pulse-retrieval algorithm. In particular, the group delay dispersion (GDD) is determined from frequency and delay marginals, which are related to the laser spectrum and intensity autocorrelation, respectively, using a simple lookup table approach. The accuracy of the estimated GDD results is confirmed via a comparison with the spectral phase distribution of the electric field reconstructed using the principal component generalized projections algorithm. It is shown that the computation time of the proposed direct estimation method is around 13 times faster than that of the traditional iterative algorithm. It thus provides a feasible approach for enabling the real-time compensation of ultrafast laser pulse compression. Moreover, in a multiphoton-excited fluorescence imaging application, the proposed pulse compression mechanism yields an effective improvement in the intensity and contrast of the reconstructed image due to the increased nonlinear optical excitation efficiency of the optimized laser pulses.
Collapse
Affiliation(s)
- Jui-Chi Chang
- Department of Mechanical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
| | - Shu-Yu Chang
- Department of Mechanical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
| | - Yu-Cheng Wu
- Department of Mechanical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
| | - Chia-Yuan Chang
- Department of Mechanical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
| |
Collapse
|
3
|
Yamaguchi A, Karagyozov D, Gershow MH. Compact and adjustable compensator for AOD spatial and temporal dispersion using off-the-shelf components. OPTICS LETTERS 2021; 46:1644-1647. [PMID: 33793507 PMCID: PMC8281507 DOI: 10.1364/ol.419682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 02/26/2021] [Indexed: 06/12/2023]
Abstract
Random access multiphoton microscopy using two orthogonal acousto-optic deflectors (AODs) allows sampling only particular regions of interest within a plane, greatly speeding up the sampling rate. AODs introduce spatial and temporal dispersions, which distort the point spread function and decrease the peak intensity of the pulse. Both of these effects can be compensated for with a single dispersive element placed a distance before the AODs. An additional acousto-optic modulator, a custom cut prism, and a standard prism used with additional cylindrical optics have been demonstrated. All of these introduce additional cost or complexity and require an extended path length to achieve the needed negative group delay dispersion (GDD). By introducing a telescope between a transmission grating and the AODs, we correct for spatial and temporal dispersions in a compact design using only off-the-shelf components, and we show that the GDD can be tuned by translation of the telescope without adjustment of any other elements.
Collapse
Affiliation(s)
- Akihiro Yamaguchi
- Department of Physics and Center for Soft Matter Research, New York University, New York, NY 10003, USA
| | - Doycho Karagyozov
- Department of Physics and Center for Soft Matter Research, New York University, New York, NY 10003, USA
| | - Marc H. Gershow
- Department of Physics and Center for Soft Matter Research, New York University, New York, NY 10003, USA
| |
Collapse
|
4
|
Tsyboulski D, Orlova N, Ledochowitsch P, Saggau P. Two-photon frequency division multiplexing for functional in vivo imaging: a feasibility study. OPTICS EXPRESS 2019; 27:4488-4503. [PMID: 30876067 DOI: 10.1364/oe.27.004488] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2018] [Accepted: 01/19/2019] [Indexed: 06/09/2023]
Abstract
Recently, we presented a new approach to create high-speed amplitude modulation of femtosecond laser pulses and tag multiple excitation beams with specific modulation frequencies. In this work, we discuss the utility of this method to record calcium signals in brain tissue with two-photon frequency-division multiplexing (2P-FDM) microscopy. While frequency-multiplexed imaging appears slightly inferior in terms of image quality as compared to conventional two-photon laser scanning microscopy due to shot noise-induced cross-talk between frequency channels, applying this technique to record average signals from regions of interest (ROI) such as neuronal cell bodies was found to be promising. We use phase information associated with each pixel or waveform within a selected ROI to phase-align and recombine the signals into one extended amplitude-modulated waveform. This procedure narrows the frequency detection window, effectively decreasing noise contributions from other frequency channels. Using theoretical analysis, numerical simulations, and in vitro imaging, we demonstrate a reduction of cross-talk by more than an order of magnitude and predict the usefulness of 2P-FDM for functional studies of brain activity.
Collapse
|
5
|
Chong EZ, Panniello M, Barreiros I, Kohl MM, Booth MJ. Quasi-simultaneous multiplane calcium imaging of neuronal circuits. BIOMEDICAL OPTICS EXPRESS 2019; 10:267-282. [PMID: 30775099 PMCID: PMC6363184 DOI: 10.1364/boe.10.000267] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 11/12/2018] [Accepted: 11/12/2018] [Indexed: 06/09/2023]
Abstract
Two-photon excitation fluorescence microscopy is widely used to study the activity of neuronal circuits. However, the fast imaging is typically constrained to a single lateral plane for a standard microscope design. Given that cortical neuronal networks in a mouse brain are complex three-dimensional structures organised in six histologically defined layers which extend over many hundreds of micrometres, there is a strong demand for microscope systems that can record neuronal signalling in volumes. Henceforth, we developed a quasi-simultaneous multiplane imaging technique combining an acousto-optic deflector and static remote focusing to provide fast imaging of neurons from different axial positions inside the cortical layers without the need for mechanical disturbance of either the objective lens or the specimen. The hardware and the software are easily adaptable to existing two-photon microscopes. Here, we demonstrated that our imaging method can record, at high speed and high image contrast, the calcium dynamics of neurons in two different imaging planes separated axially with the in-focus and the refocused planes 120 µm and 250 µm below the brain surface respectively.
Collapse
Affiliation(s)
- Ee Zhuan Chong
- Department of Engineering Science, University of Oxford, Parks Road, OX1 3PJ, UK
| | - Mariangela Panniello
- Department of Physiology, Anatomy and Genetics, University of Oxford, Parks Road, OX1 3PT, UK
| | - Inês Barreiros
- Department of Physiology, Anatomy and Genetics, University of Oxford, Parks Road, OX1 3PT, UK
| | - Michael M Kohl
- Department of Physiology, Anatomy and Genetics, University of Oxford, Parks Road, OX1 3PT, UK
| | - Martin J Booth
- Department of Engineering Science, University of Oxford, Parks Road, OX1 3PJ, UK
| |
Collapse
|
6
|
Tsyboulski D, Orlova N, Saggau P. Amplitude modulation of femtosecond laser pulses in the megahertz range for frequency-multiplexed two-photon imaging. OPTICS EXPRESS 2017; 25:9435-9442. [PMID: 28437905 DOI: 10.1364/oe.25.009435] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We present a frequency-multiplexed multi-site two-photon imaging method utilizing amplitude modulation of femtosecond laser pulses in the MHz range to tag each excitation beam and the corresponding fluorescence signals with specific frequencies. The frequency tags are generated with an interferometric scheme employing acousto-optic deflectors (AODs) to achieve precise spatial overlap of femtosecond laser pulses with periodically varying phase shift. Creating matching excitation beam patterns in each interferometer arm using multiple AOD driving frequencies, and subsequently overlapping these matching patterns, results in multiple encoded excitation beams with unique beat frequencies available for scanning. As a proof-of-concept, we demonstrate multiplexed two-photon image acquisition using test samples, and compare the performance of this approach to conventional two-photon laser scanning microscopy.
Collapse
|
7
|
Grewe BF, Helmchen F. High-speed two-photon calcium imaging of neuronal population activity using acousto-optic deflectors. Cold Spring Harb Protoc 2014; 2014:618-29. [PMID: 24890212 DOI: 10.1101/pdb.prot081778] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Two-photon calcium imaging of neuronal populations allows optical measurements of spiking activity in living animals. However, laser-scanning microscopes with galvanometric scan mirrors are too slow to capture population activity on a millisecond timescale. This protocol describes a two-photon microscope that is based on two-dimensional laser scanning with acousto-optic deflectors (AODs), enabling high-speed in vivo recording of neuronal population activity at temporal resolutions of several hundred hertz. The detailed construction plan of the AOD-based microscope is accompanied by equally detailed optimization procedures. We also introduce a novel random-access pattern scanning (RAPS) technique for high-speed in vivo measurements of neuronal population activity. AOD-based RAPS can measure calcium transients in neocortical neuronal populations, revealing spike trains with near-millisecond precision. The current limitations of the AOD-based microscope are discussed, and we provide an outlook of its future applications.
Collapse
|
8
|
Abstract
Neurons in the mammalian brain receive thousands of synaptic inputs on their dendrites. In many types of neurons, such as cortical pyramidal neurons, excitatory synapses are formed on fine dendritic protrusions called spines. Usually, an individual spine forms a single synaptic contact with an afferent axon. In this protocol, we describe a recently established experimental procedure for measuring intracellular calcium signals from dendritic spines in cortical neurons in vivo by using a combination of two-photon microscopy and whole-cell patch-clamp recordings. We have used mice as an experimental model system, but the protocol may be readily adapted to other species. This method involves data acquisition at high frame rates and low-excitation laser power, and is termed low-power temporal oversampling (LOTOS). Because of its high sensitivity of fluorescence detection and reduced phototoxicity, LOTOS allows for prolonged and stable calcium imaging in vivo. Key aspects of the protocol, which can be completed in 5-6 h, include the use of a variant of high-speed two-photon imaging, refined surgery procedures and optimized tissue stabilization.
Collapse
|
9
|
Random-access Two-photon Microscopy for Neural Activity Observation*. PROG BIOCHEM BIOPHYS 2012. [DOI: 10.3724/sp.j.1206.2012.00234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
10
|
Jiang R, Zhou Z, Lv X, Zeng S. Wide-band acousto-optic deflectors for large field of view two-photon microscope. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:043709. [PMID: 22559541 DOI: 10.1063/1.4705972] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Acousto-optic deflector (AOD) is an attractive scanner for two-photon microscopy because it can provide fast and versatile laser scanning and does not involve any mechanical movements. However, due to the small scan range of available AOD, the field of view (FOV) of the AOD-based microscope is typically smaller than that of the conventional galvanometer-based microscope. Here, we developed a novel wide-band AOD to enlarge the scan angle. Considering the maximum acceptable acoustic attenuation in the acousto-optic crystal, relatively lower operating frequencies and moderate aperture were adopted. The custom AOD was able to provide 60 MHz 3-dB bandwidth and 80% peak diffraction efficiency at 840 nm wavelength. Based on a pair of such AOD, a large FOV two-photon microscope was built with a FOV up to 418.5 μm (40× objective). The spatiotemporal dispersion was compensated simultaneously with a single custom-made prism. By means of dynamic power modulation, the variation of laser intensity within the FOV was reduced below 5%. The lateral and axial resolution of the system were 0.58-2.12 μm and 2.17-3.07 μm, respectively. Pollen grain images acquired by this system were presented to demonstrate the imaging capability at different positions across the entire FOV.
Collapse
Affiliation(s)
- Runhua Jiang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430074, China
| | | | | | | |
Collapse
|
11
|
Quan T, Liu X, Lv X, Chen WR, Zeng S. Method to reconstruct neuronal action potential train from two-photon calcium imaging. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:066002. [PMID: 21198176 PMCID: PMC3032232 DOI: 10.1117/1.3505021] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Identification of a small population of neuronal action potentials (APs) firing is considered essential to discover the operating principles of neuronal circuits. A promising method is to indirectly monitor the AP discharges in neurons from the recordings their intracellular calcium fluorescence transients. However, it is hard to reveal the nonlinear relationship between neuronal calcium fluorescence transients and the corresponding AP burst discharging. We propose a method to reconstruct the neuronal AP train from calcium fluorescence diversifications based on a multiscale filter and a convolution operation. Results of experimental data processing show that the false-positive rate and the event detection rate are about 10 and 90%, respectively. Meanwhile, the APs firing at a high frequency up to 40 Hz can also be successfully identified. From the results, it can be concluded that the method has strong power to reconstruct a neuronal AP train from a burst firing.
Collapse
Affiliation(s)
- Tingwei Quan
- Huazhong University of Science and Technology, Wuhan National Laboratory for Optoelectronics, Wuhan 430074, China
| | | | | | | | | |
Collapse
|
12
|
Losavio BE, Iyer V, Saggau P. Two-photon microscope for multisite microphotolysis of caged neurotransmitters in acute brain slices. JOURNAL OF BIOMEDICAL OPTICS 2009; 14:064033. [PMID: 20059271 PMCID: PMC2809696 DOI: 10.1117/1.3275468] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
We developed a two-photon microscope optimized for physiologically manipulating single neurons through their postsynaptic receptors. The optical layout fulfills the stringent design criteria required for high-speed, high-resolution imaging in scattering brain tissue with minimal photodamage. We detail the practical compensation of spectral and temporal dispersion inherent in fast laser beam scanning with acousto-optic deflectors, as well as a set of biological protocols for visualizing nearly diffraction-limited structures and delivering physiological synaptic stimuli. The microscope clearly resolves dendritic spines and evokes electrophysiological transients in single neurons that are similar to endogenous responses. This system enables the study of multisynaptic integration and will assist our understanding of single neuron function and dendritic computation.
Collapse
Affiliation(s)
- Bradley E Losavio
- Baylor College of Medicine, Department of Neuroscience, One Baylor Plaza, Houston, Texas 77030, USA
| | | | | |
Collapse
|
13
|
Zeng S, Luo Q, Li D, Lü X. Femtosecond pulse laser scanning using Acousto-Optic Deflector. ACTA ACUST UNITED AC 2009. [DOI: 10.1007/s11433-009-0101-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
14
|
Reduction of the pulse duration of the ultrafast laser pulses of the Two-Photon Laser Scanning Microscopy (2PLSM). BMC Res Notes 2008; 1:39. [PMID: 18710492 PMCID: PMC2519073 DOI: 10.1186/1756-0500-1-39] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2008] [Accepted: 07/09/2008] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND We provide an update of our two-photon laser scanning microscope by compressing or reducing the broadening of the pulse width of ultrafast laser pulses for dispersion precompensation, to enable the pulses to penetrate deeply inside the sample. FINDINGS The broadening comes as the pulses pass through the optical elements. We enhanced and modified the quality and the sharpness of images by enhancing the resolution using special polarizer namely Glan Laser polarizer GL10. This polarizer consists of two prisms separated by air space. This air separation between the two prisms uses to delay the red wavelength when the light leaves the first prism to the air then to second prism. We note a considerable enhancing with using the GL polarizer, and we can see the details of the leaf structure in early stages when we trying to get focus through z-stacks of images in comparison to exactly the same measurements without using GL polarizer. Hence, with this modification we able to reduce the time of exposure the sample to the laser radiation thereby we will reduce the probability of photobleaching and phototoxicity. When the pulse width reduced, the average power of the laser pulses maintained at a constant level. Significant enhancement is found between the two kinds of images of the Two-Photon Excitation Fluorescence (TPEF). CONCLUSION In summary reduction the laser pulse width allowed to collect more diffraction orders which will used to form the images. The more diffraction orders the higher resolution images.
Collapse
|
15
|
Otsu Y, Bormuth V, Wong J, Mathieu B, Dugué GP, Feltz A, Dieudonné S. Optical monitoring of neuronal activity at high frame rate with a digital random-access multiphoton (RAMP) microscope. J Neurosci Methods 2008; 173:259-70. [PMID: 18634822 DOI: 10.1016/j.jneumeth.2008.06.015] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2008] [Revised: 06/10/2008] [Accepted: 06/16/2008] [Indexed: 01/15/2023]
Abstract
Two-photon microscopy offers the promise of monitoring brain activity at multiple locations within intact tissue. However, serial sampling of voxels has been difficult to reconcile with millisecond timescales characteristic of neuronal activity. This is due to the conflicting constraints of scanning speed and signal amplitude. The recent use of acousto-optic deflector scanning to implement random-access multiphoton microscopy (RAMP) potentially allows to preserve long illumination dwell times while sampling multiple points-of-interest at high rates. However, the real-life abilities of RAMP microscopy regarding sensitivity and phototoxicity issues, which have so far impeded prolonged optical recordings at high frame rates, have not been assessed. Here, we describe the design, implementation and characterisation of an optimised RAMP microscope. We demonstrate the application of the microscope by monitoring calcium transients in Purkinje cells and cortical pyramidal cell dendrites and spines. We quantify the illumination constraints imposed by phototoxicity and show that stable continuous high-rate recordings can be obtained. During these recordings the fluorescence signal is large enough to detect spikes with a temporal resolution limited only by the calcium dye dynamics, improving upon previous techniques by at least an order of magnitude.
Collapse
Affiliation(s)
- Yo Otsu
- Laboratoire de Neurobiologie, CNRS UMR 8544, Ecole Normale Supérieure, 46 rue d'Ulm 75005, Paris, France
| | | | | | | | | | | | | |
Collapse
|
16
|
Liu X, Gong H, Li X, Zhou W. Monitoring calcium concentration in neurons with cameleon. J Biosci Bioeng 2008; 105:106-9. [PMID: 18343335 DOI: 10.1263/jbb.105.106] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2007] [Accepted: 11/02/2007] [Indexed: 11/17/2022]
Abstract
The calcium ion, a second messenger in the brain, plays key roles in neuronal signaling pathways. Ca(2+) signals in neurons are often highly localized and difficult to measure accurately. The quantification of calcium concentration is thus critical for understanding neuronal signaling. In this study, a yellow cameleon (YC3.60) excited using a 458 nm laser was used to monitor the calcium signals in neurons, and the dynamic range (R(max)/R(min)) of YC3.60 was found to reach 250%. The spatial distribution of calcium and the physiological changes in hippocampal neurons and even in spines were determined by the fluorescence resonance energy transfer (FRET) method. It was proved that cameleon could be used for the quantitative measurement of calcium concentration in neurons. Fluorescence readout of the calcium concentration in neurons by FRET is nondestructive, quantifiable with high spatiotemporal resolution, and even applicable to dendritic spines.
Collapse
Affiliation(s)
- Xiuli Liu
- Britton Chance Center for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan 430074, PR China
| | | | | | | |
Collapse
|