Sassaroli A, Blaney G, Fantini S. Novel data types for frequency-domain diffuse optical spectroscopy and imaging of tissues: characterization of sensitivity and contrast-to-noise ratio for absorption perturbations. BIOMEDICAL OPTICS EXPRESS 2023; 14:2091-2116. [PMID: 37206129 PMCID: PMC10191659 DOI: 10.1364/boe.485651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 03/08/2023] [Accepted: 03/28/2023] [Indexed: 05/21/2023]
Abstract
In frequency-domain (FD) diffuse optics it is known that the phase of photon-density waves (ϕ) has a stronger deep-to-superficial sensitivity ratio to absorption perturbations than the alternate current (AC) amplitude, or the direct current intensity (DC). This work is an attempt to find FD data types that feature similar or even better sensitivity and/or contrast-to-noise for deeper absorption perturbations than phase. One way is to start from the definition of characteristic function (Xt(ω)) of the photon's arrival time (t) and combining the real (ℜ ( X t ( ω ) ) = A C D C c o s ( ϕ ) ) and imaginary parts (ℑ [ X t ( ω ) ] = A C D C s i n ( ϕ ) ) with phase to yield new data types. These new data types enhance the role of higher order moments of the probability distribution of the photon's arrival time t. We study the contrast-to-noise and sensitivity features of these new data types not only in the single-distance arrangement (traditionally used in diffuse optics), but we also consider the spatial gradients, which we named dual-slope arrangements. We have identified six data types that for typical values of the optical properties of tissues and depths of interest, have better sensitivity or contrast-to-noise features than phase data and that can be used to enhance the limits of imaging of tissue in FD near infrared spectroscopy (NIRS). For example, one promising data type is ϕ - ℑ [ X t ( ω ) ] which shows, in the single-distance source-detector arrangement, an increase of deep-to-superficial sensitivity ratio with respect to phase by 41% and 27% at a source-detector separation of 25 and 35 mm, respectively. The same data type also shows an increase of contrast-to noise up to 35% with respect to phase when the spatial gradients of the data are considered.
Collapse
Affiliation(s)
- Angelo Sassaroli
- Department of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, MA 02155, USA
| | - Giles Blaney
- Department of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, MA 02155, USA
| | - Sergio Fantini
- Department of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, MA 02155, USA
| |
Collapse
|
2
|
Blaney G, Fernandez C, Sassaroli A, Fantini S. Dual-slope imaging of cerebral hemodynamics with frequency-domain near-infrared spectroscopy. NEUROPHOTONICS 2023; 10:013508. [PMID: 36601543 PMCID: PMC9807277 DOI: 10.1117/1.nph.10.1.013508] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Accepted: 12/08/2022] [Indexed: 06/17/2023]
Abstract
Significance This work targets the contamination of optical signals by superficial hemodynamics, which is one of the chief hurdles in non-invasive optical measurements of the human brain. Aim To identify optimal source-detector distances for dual-slope (DS) measurements in frequency-domain (FD) near-infrared spectroscopy (NIRS) and demonstrate preferential sensitivity of DS imaging to deeper tissue (brain) versus superficial tissue (scalp). Approach Theoretical studies (in-silico) based on diffusion theory in two-layered and in homogeneous scattering media. In-vivo demonstrations of DS imaging of the human brain during visual stimulation and during systemic blood pressure oscillations. Results The mean distance (between the two source-detector distances needed for DS) is the key factor for depth sensitivity. In-vivo imaging of the human occipital lobe with FD NIRS and a mean distance of 31 mm indicated: (1) greater hemodynamic response to visual stimulation from FD phase versus intensity, and from DS versus single-distance (SD); (2) hemodynamics from FD phase and DS mainly driven by blood flow, and hemodynamics from SD intensity mainly driven by blood volume. Conclusions DS imaging with FD NIRS may suppress confounding contributions from superficial hemodynamics without relying on data at short source-detector distances. This capability can have significant implications for non-invasive optical measurements of the human brain.
Collapse
Affiliation(s)
- Giles Blaney
- Tufts University, Department of Biomedical Engineering, Medford, Massachusetts, United States
| | - Cristianne Fernandez
- Tufts University, Department of Biomedical Engineering, Medford, Massachusetts, United States
| | - Angelo Sassaroli
- Tufts University, Department of Biomedical Engineering, Medford, Massachusetts, United States
| | - Sergio Fantini
- Tufts University, Department of Biomedical Engineering, Medford, Massachusetts, United States
| |
Collapse
|
3
|
Perkins GA, Eggebrecht AT, Dehghani H. Multi-modulated frequency domain high density diffuse optical tomography. BIOMEDICAL OPTICS EXPRESS 2022; 13:5275-5294. [PMID: 36425621 PMCID: PMC9664897 DOI: 10.1364/boe.467614] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 08/13/2022] [Accepted: 08/15/2022] [Indexed: 05/11/2023]
Abstract
Frequency domain (FD) high density diffuse optical tomography (HD-DOT) utilising varying or combined modulation frequencies (mFD) has shown to theoretically improve the imaging accuracy as compared to conventional continuous wave (CW) measurements. Using intensity and phase data from a solid inhomogeneous phantom (NEUROPT) with three insertable rods containing different contrast anomalies, at modulation frequencies of 78 MHz, 141 MHz and 203 MHz, HD-DOT is applied and quantitatively evaluated, showing that mFD outperforms FD and CW for both absolute (iterative) and temporal (linear) tomographic imaging. The localization error (LOCA), full width half maximum (FWHM) and effective resolution (ERES) were evaluated. Across all rods, the LOCA of mFD was 61.3% better than FD and 106.1% better than CW. For FWHM, CW was 6.0% better than FD and mFD and for ERES, mFD was 1.20% better than FD and 9.83% better than CW. Using mFD data is shown to minimize the effect of inherently noisier FD phase data whilst maximising its strengths through improved contrast.
Collapse
Affiliation(s)
- Guy A. Perkins
- University of Birmingham, Sci-Phy-4-Health Centre for Doctoral Training, College of Engineering and Physical Sciences, Birmingham, B15 2TT, UK
- University of Birmingham, School of Computer Science, College of Engineering and Physical Sciences, Birmingham, B15 2TT, UK
| | - Adam T. Eggebrecht
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri, 63110, USA
| | - Hamid Dehghani
- University of Birmingham, School of Computer Science, College of Engineering and Physical Sciences, Birmingham, B15 2TT, UK
| |
Collapse
|
4
|
Wojtkiewicz S, Bejm K, Liebert A. Lock-in functional near-infrared spectroscopy for measurement of the haemodynamic brain response. BIOMEDICAL OPTICS EXPRESS 2022; 13:1869-1887. [PMID: 35519260 PMCID: PMC9045899 DOI: 10.1364/boe.448038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 02/13/2022] [Accepted: 02/15/2022] [Indexed: 06/14/2023]
Abstract
Here we show a method of the lock-in amplifying near-infrared signals originating within a human brain. It implies using two 90-degree rotated source-detector pairs fixed on a head surface. Both pairs have a joint sensitivity region located towards the brain. A direct application of the lock-in technique on both signals results in amplifying common frequency components, e.g. related to brain cortex stimulation and attenuating the rest, including all components not related to the stimulation: e.g. pulse, instrumental and biological noise or movement artefacts. This is a self-driven method as no prior assumptions are needed and the noise model is provided by the interfering signals themselves. We show the theory (classical modified Beer-Lambert law and diffuse optical tomography approaches), the algorithm implementation and tests on a finite element mathematical model and in-vivo on healthy volunteers during visual cortex stimulation. The proposed hardware and algorithm complexity suit the entire spectrum of (continuous wave, frequency domain, time-resolved) near-infrared spectroscopy systems featuring real-time, direct, robust and low-noise brain activity registration tool. As such, this can be of special interest in optical brain computer interfaces and high reliability/stability monitors of tissue oxygenation.
Collapse
|
5
|
Stillwell RA, Kitsmiller VJ, Wei AY, Chong A, Senn L, O’Sullivan TD. A scalable, multi-wavelength, broad bandwidth frequency-domain near-infrared spectroscopy platform for real-time quantitative tissue optical imaging. BIOMEDICAL OPTICS EXPRESS 2021; 12:7261-7279. [PMID: 34858713 PMCID: PMC8606133 DOI: 10.1364/boe.435913] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 10/07/2021] [Accepted: 10/21/2021] [Indexed: 05/25/2023]
Abstract
Frequency-domain near-infrared spectroscopy (FD-NIRS) provides quantitative noninvasive measurements of tissue optical absorption and scattering, as well as a safe and accurate method for characterizing tissue composition and metabolism. However, the poor scalability and high complexity of most FD-NIRS systems assembled to date have contributed to its limited clinical impact. To address these shortcomings, we present a scalable, digital-based FD-NIRS platform capable of measuring optical properties and tissue chromophore concentrations in real-time. The system provides single-channel FD-NIRS amplitude/phase, optical property, and chromophore data at a maximum display rate of 36.6 kHz, 17.9 kHz, and 10.2 kHz, respectively, and can be scaled to multiple channels as well as integrated into a handheld format. The entire system is enabled by several innovations including an ultra-high-speed k-nearest neighbor lookup table method (maximum of 250,000 inversions/s for a large 2500x700 table of absorption and reduced scattering coefficients), embedded FPGA and CPU high-speed co-processing, and high-speed data transfer (due to on-board processing). We show that our 6-wavelength, broad modulation bandwidth (1-400 MHz) system can be used to perform 2D high-density spatial mapping of optical properties and high speed quantification of hemodynamics.
Collapse
Affiliation(s)
- Roy A. Stillwell
- Department of Electrical Engineering, University of Notre Dame, Notre Dame, Indiana 46556, USA
| | - Vincent J. Kitsmiller
- Department of Electrical Engineering, University of Notre Dame, Notre Dame, Indiana 46556, USA
| | - Alicia Y. Wei
- Department of Electrical Engineering, University of Notre Dame, Notre Dame, Indiana 46556, USA
| | - Alyssa Chong
- St. Mary’s College, Notre Dame, Indiana 46556, USA
| | - Lyla Senn
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, Indiana 46556, USA
| | - Thomas D. O’Sullivan
- Department of Electrical Engineering, University of Notre Dame, Notre Dame, Indiana 46556, USA
| |
Collapse
|
6
|
Fan W, Dehghani H, Eggebrecht AT. Investigation of effect of modulation frequency on high-density diffuse optical tomography image quality. NEUROPHOTONICS 2021; 8:045002. [PMID: 34849379 PMCID: PMC8612746 DOI: 10.1117/1.nph.8.4.045002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 11/04/2021] [Indexed: 05/16/2023]
Abstract
Significance: By incorporating multiple overlapping functional near-infrared spectroscopy (fNIRS) measurements, high-density diffuse optical tomography (HD-DOT) images human brain function with fidelity comparable to functional magnetic resonance imaging (fMRI). Previous work has shown that frequency domain high-density diffuse optical tomography (FD-HD-DOT) may further improve image quality over more traditional continuous wave (CW) HD-DOT. Aim: The effects of modulation frequency on image quality as obtainable with FD-HD-DOT is investigated through simulations with a realistic noise model of functional activations in human head models, arising from 11 source modulation frequencies between CW and 1000 MHz. Approach: Simulations were performed using five representative head models with an HD regular grid of 158 light sources and 166 detectors and an empirically derived noise model. Functional reconstructions were quantitatively assessed with multiple image quality metrics including the localization error (LE), success rate, full width at half maximum, and full volume at half maximum (FVHM). All metrics were evaluated against CW-based models. Results: Compared to CW, localization accuracy is improved by >40% throughout brain depths of 13 to 25 mm below the surface with 300 to 500 MHz modulation frequencies. Additionally, the reliable field of view in brain tissue is enlarged by 35% to 48% within an optimal frequency of 300 MHz after considering realistic noise, depending on the dynamic range of the system. Conclusions: These results point to the tremendous opportunities in further development of high bandwidth FD-HD-DOT system hardware for applications in human brain mapping.
Collapse
Affiliation(s)
- Weihao Fan
- Washington University, Department of Physics, St. Louis, Missouri, United States
| | - Hamid Dehghani
- University of Birmingham, School of Computer Science, Birmingham, United Kingdom
| | - Adam T. Eggebrecht
- Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, Missouri, United States
- Washington University, Department of Biomedical Engineering, St. Louis, Missouri, United States
| |
Collapse
|