1
|
Mizoguchi T, Tameshige Y, Kaneda T, Ogawa Y, Muranaka Y, Tamamura H. [Estimation of Uncertainty of the VMAT Absolute Dose Measurement Due to the Phantom Setup Error Using a Treatment Planning System]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2024; 80:345-353. [PMID: 38447969 DOI: 10.6009/jjrt.2024-1371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2024]
Abstract
PURPOSE When performing single-point dose verification in VMAT, it is necessary to avoid the regions with steep dose gradient. We propose a method to obtain the estimated value ( Uplan) of uncertainty of the absolute dose measurement due to the phantom setup error by using dose gradient calculated from treatment planning system (TPS), for evaluating the appropriate measurement points. METHODS The dose gradient was calculated from the planned dose values in the vicinity of the isocenter point using TPS. The phantom setup error was estimated. The Uplan was calculated using the proposed formula after estimating the phantom setup error. Then, the dose gradient was calculated from the measured dose values in the vicinity of the isocenter point specified by TPS using the Tough water phantom with ionization chamber (IC), and Umeas was calculated as in Uplan. RESULTS The correlation coefficient between Uplan and Umeas was 0.984, which indicates a high correlation. The average of the difference between Umeas and Uplan was -0.24%. We considered that this result was caused by the influence of volume averaging effect of IC. CONCLUSION The Uplan obtained from this proposed method reflects the uncertainty of the absolute dose measurement due to the phantom setup error and is useful for evaluating the appropriate measurement points for absolute dose measurement.
Collapse
Affiliation(s)
| | - Yuji Tameshige
- Division of Radiation Therapy, Nuclear Medicine Department, Fukui, Prefectural Hospital
| | - Tatsuya Kaneda
- Department of Radiological Technology, Fukui Prefectural Hospital
| | - Yoshiji Ogawa
- Department of Radiological Technology, Fukui Prefectural Hospital
| | | | | |
Collapse
|
2
|
Zhou Y, Liu Y, Chen M, Fang J, Xiao L, Huang S, Qi Z, Deng X, Zhang J, Peng Y. Commissioning and clinical evaluation of a novel high-resolution quality assurance digital detector array for SRS and SBRT. J Appl Clin Med Phys 2024; 25:e14258. [PMID: 38175960 PMCID: PMC11005972 DOI: 10.1002/acm2.14258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 12/03/2023] [Accepted: 12/18/2023] [Indexed: 01/06/2024] Open
Abstract
PURPOSE We aimed to perform the commissioning and clinical evaluation of myQA SRS detector array for patient-specific quality assurance (PSQA) of stereotactic radiosurgery (SRS)/ stereotactic body radiotherapy (SBRT) plans. METHODS To perform the commissioning of myQA SRS, its dose linearity, dose-rate dependence, angular dependence, and field-size dependence were investigated. Ten SBRT plans were selected for clinical evaluation: 1) Common clinical deviations based on the original SBRT plan (Plan0), including multileaf collimator (MLC) positioning deviation and treatment positioning deviation were introduced. 2) Compared the performance of the myQA SRS and a high-resolution EPID dosimetry system in PSQA measurement for the SBRT plans. Evaluation parameters include gamma passing rate (GPR) and distance-to-agreement (DTA) pass rate (DPR). RESULTS The dose linearity, angle dependence, and field-size dependence of myQA SRS system exhibit excellent performance. The myQA SRS is highly sensitive in the detection of MLC deviations. The GPR of (3%/1 mm) decreases from 90.4% of the original plan to 72.7%/62.9% with an MLC outward/inward deviation of 3 mm. Additionally, when the setup error deviates by 1 mm in the X, Y, and Z directions with the GPR of (3%/1 mm) decreasing by an average of -20.9%, -25.7%, and -24.7%, respectively, and DPR (1 mm) decreasing by an average of -33.7%, -32.9%, and -29.8%. Additionally, the myQA SRS has a slightly higher GPR than EPID for PSQA, However, the difference is not statistically significant with the GPR of (3%/1 mm) of (average 90.4%% vs. 90.1%, p = 0.414). CONCLUSION Dosimetry characteristics of the myQA SRS device meets the accuracy and sensitivity requirement of PSQA for SRS/SBRT treatment. The dose rate dependence should be adequately calibrated before its application and a more stringent GPR (3%/1 mm) evaluation criterion is suggested when it is used for SRS/SBRT QA.
Collapse
Affiliation(s)
- Yang Zhou
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
- Department of Radiation Oncology, Zhuzhou Hospital Affiliated to Xiangya School of MedicineCentral South UniversityZhuzhouP. R. China
| | - Yimei Liu
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Meining Chen
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Jianlan Fang
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Liangjie Xiao
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Shaomin Huang
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Zhenyu Qi
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Xiaowu Deng
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Jun Zhang
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Yinglin Peng
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| |
Collapse
|
3
|
De Saint-Hubert M, Caprioli M, de Freitas Nascimento L, Delombaerde L, Himschoot K, Vandenbroucke D, Leblans P, Crijns W. New optically stimulated luminescence dosimetry film optimized for energy dependence guided by Monte Carlo simulations. Phys Med Biol 2024; 69:075005. [PMID: 38394683 DOI: 10.1088/1361-6560/ad2ca2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Accepted: 02/23/2024] [Indexed: 02/25/2024]
Abstract
Optically stimulated luminescence (OSL) film dosimeters, based on BaFBr:Eu2+phosphor material, have major dosimetric advantages such as dose linearity, high spatial resolution, film re-usability, and immediate film readout. However, they exhibit an energy-dependent over-response at low photon energies because they are not made of tissue-equivalent materials. In this work, the OSL energy-dependent response was optimized by lowering the phosphor grain size and seeking an optimal choice of phosphor concentration and film thickness to achieve sufficient signal sensitivity. This optimization process combines measurement-based assessments of energy response in narrow x-ray beams with various energy response calculation methods applied to different film metrics. Theoretical approaches and MC dose simulations were used for homogeneous phosphor distributions and for isolated phosphor grains of different dimensions, where the dose in the phosphor grain was calculated. In total 8 OSL films were manufactured with different BaFBr:Eu2+median particle diameters (D50): 3.2μm, 1.5μm and 230 nm and different phosphor concentrations (1.6%, 5.3% and 21.3 %) and thicknesses (from 5.2 to 49μm). Films were irradiated in narrow x-ray spectra (N60, N80, N-150 and N-300) and the signal intensity relative to the nominal dose-to-water value was normalized to Co-60. Finally, we experimentally tested the response of several films in Varian 6MV TrueBeam STx linear accelerator using the following settings: 10 × 10 cm2field, 0deggantry angle, 90 cm SSD, 10 cm depth. The x-ray irradiation experiment reported a reduced energy response for the smallest grain size with an inverse correlation between response and grain size. The N-60 irradiation showed a 43% reduction in the energy over-response when going from 3μm to 230 nm grain size for the 5% phosphor concentration. Energy response calculation using a homogeneous dispersion of the phosphor underestimated the experimental response and was not able to obtain the experimental correlation between grain size and energy response. Isolated grain size modeling combined with MC dose simulations allowed to establish a good agreement with experimental data, and enabled steering the production of optimized OSL-films. The clinical 6 MV beam test confirmed a reduction in energy dependence, which is visible in small-grain films where a decrease in out-of-field over-response was observed.
Collapse
Affiliation(s)
| | - Marco Caprioli
- Department of Oncology, KU Leuven, Herestraat 49, Leuven, Belgium
| | | | - Laurence Delombaerde
- Department of Oncology, KU Leuven, Herestraat 49, Leuven, Belgium
- Department of Radiation Oncology, University Hospitals Leuven, Herestraat 49, Leuven, B-3000, Belgium
| | - Katleen Himschoot
- Corporate Innovation Office, Agfa N.V., Septestraat 27, Mortsel, B-2640, Belgium
| | - Dirk Vandenbroucke
- Corporate Innovation Office, Agfa N.V., Septestraat 27, Mortsel, B-2640, Belgium
| | - Paul Leblans
- Corporate Innovation Office, Agfa N.V., Septestraat 27, Mortsel, B-2640, Belgium
| | - Wouter Crijns
- Department of Radiation Oncology, University Hospitals Leuven, Herestraat 49, Leuven, B-3000, Belgium
| |
Collapse
|
4
|
Karger CP, Elter A, Dorsch S, Mann P, Pappas E, Oldham M. Validation of complex radiotherapy techniques using polymer gel dosimetry. Phys Med Biol 2024; 69:06TR01. [PMID: 38330494 DOI: 10.1088/1361-6560/ad278f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 02/08/2024] [Indexed: 02/10/2024]
Abstract
Modern radiotherapy delivers highly conformal dose distributions to irregularly shaped target volumes while sparing the surrounding normal tissue. Due to the complex planning and delivery techniques, dose verification and validation of the whole treatment workflow by end-to-end tests became much more important and polymer gel dosimeters are one of the few possibilities to capture the delivered dose distribution in 3D. The basic principles and formulations of gel dosimetry and its evaluation methods are described and the available studies validating device-specific geometrical parameters as well as the dose delivery by advanced radiotherapy techniques, such as 3D-CRT/IMRT and stereotactic radiosurgery treatments, the treatment of moving targets, online-adaptive magnetic resonance-guided radiotherapy as well as proton and ion beam treatments, are reviewed. The present status and limitations as well as future challenges of polymer gel dosimetry for the validation of complex radiotherapy techniques are discussed.
Collapse
Affiliation(s)
- Christian P Karger
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Alina Elter
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
- Department of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, D-69120 Heidelberg, Germany
| | - Stefan Dorsch
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Philipp Mann
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Evangelos Pappas
- Radiology & Radiotherapy Sector, Department of Biomedical Sciences, University of West Attica, Athens, Greece
| | - Mark Oldham
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, United States of America
| |
Collapse
|
5
|
Li F, Price M. Commissioning of Mobius3D/FX for patient-specific quality assurance: The CUIMC-NewYork Presbyterian Hospital experience. J Appl Clin Med Phys 2024; 25:e14183. [PMID: 37849358 PMCID: PMC10860561 DOI: 10.1002/acm2.14183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 09/20/2023] [Accepted: 10/02/2023] [Indexed: 10/19/2023] Open
Abstract
PURPOSE To present the process undertaken by our institute in commissioning Mobius3D (M3D) for patient-specific quality assurance. METHOD 168 plans were randomly selected to compare dose distribution measured with ArcCheck and dose calculated from M3D, both compared against the treatment planning system (TPS). The gamma criteria for measurement and M3D are 3%/2 mm with 10% and 50% dose thresholds, respectively. The effect of tissue inhomogeneity was investigated on 11 plans by recalculating the dose in M3D on a homogeneous phantom. Tolerance and action limits were established following the AAPM Task Group 218 recommendations. RESULTS The M3D showed high variability in gamma passing rate compared to the measurement. Twenty-three out of 168 plans had false negative dose comparisons. These plans fall under high tissue inhomogeneity like lung and metal implants, small field targets, and breast plans planned with high energy. One false negative case (0.6%) was observed. A single tolerance limit of 91% and 92% gamma passing rate for the M3D and measurement-based PSQA were established, respectively. Against the expectation, recalculating plans on the homogeneous phantom in M3D did not necessarily increase the gamma passing rate. These plans have a duty cycle >4.2, and the small field sizes combined with differences in slice thickness contributed to observed dose differences in the homogeneous phantom comparisons. CONCLUSION Following the commissioning, M3D is adopted in our institute. Currently, the gamma criteria used for measurement and M3D are 3%/2 mm, 40% dose threshold, with gamma passing rates of 92% and 95%, respectively. A higher passing rate for M3D is adopted until more data is available. The combined effect of plan modulation, the field sizes, the tissue inhomogeneity, the dose algorithm, and the volume averaging effect from differences in slice thickness can contribute to the differences in dose in M3D and TPS.
Collapse
Affiliation(s)
- Fiona Li
- Department of Radiation OncologyColumbia University Irving Medical CenterNew YorkNew YorkUSA
| | - Michael Price
- Department of Radiation OncologyColumbia University Irving Medical CenterNew YorkNew YorkUSA
| |
Collapse
|
6
|
Cavalli N, Bonanno E, Borzì GR, D'Anna A, Pace M, Stella G, Zirone L, Marino C. Is it still necessary to perform measured based pre-treatment patient-specific QA for SRS HyperArc treatments? J Appl Clin Med Phys 2024; 25:e14156. [PMID: 37803884 PMCID: PMC10860540 DOI: 10.1002/acm2.14156] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 05/04/2023] [Accepted: 08/22/2023] [Indexed: 10/08/2023] Open
Abstract
PURPOSE The Mobius3D system was validated as a modern secondary check dosimetry system. In particular, our objective has been to assess the suitability of the M3D as pre-treatment patient-specific Quality Assurance (QA) tool for Stereotactic Radiosurgery (SRS) HyperArc (HA) treatments. We aimed to determine whether Mobius3D could safely replace the measurements-based patient-specific QA for this type of treatment. METHODS 30 SRS HA treatment plans for brain were selected. The dose distributions, calculated by Mobius and our routinely used algorithm (AcurosXB v.15.6), were compared using gamma analysis index and DVH parameters based on the patient's CT dataset. All 30 plans were then delivered across the ionization chamber in a homogeneous phantom and the measured dose was compared with both M3D and TPS calculated one. The plans were delivered and verified in terms of PSQA using the electronic portal imaging device (EPID) with Portal Dosimetry (PD) and myQA SRS (IBA Dosimetry) detector. Plans that achieved a global gamma passing rate (GPR) ≥ 97% based on 2%/2 mm criteria, with both Mobius3D and the conventional methods were evaluated acceptable. Finally, we assessed the capability of the M3D system to detect errors related to the position of the Multi-Leaf Collimator (MLC) in comparison to the analyzed measurement-based systems. RESULTS No relevant differences were observed in the comparison between the dose calculated on the CT-dataset by M3D and the TPS. Observed discrepancies are imputable to different used algorithms, but no discrepancies related to goodness of plans have been found. Average differences between calculated (M3D and TPS) vs measured dose with ionization chamber were 2.5% (from 0.41% to 3.2%) and 1.81% (from 0.66% to 2.65%), for M3D and TPS, respectively. All plans passed with a gamma passing rate > 97% using conventional PSQA methods with a gamma criterion of 2% dose difference and 2 mm distance-to-agreement. The average gamma passing rate for the M3D system was determined to be 99.4% (from 97.3% to 100%). Results from this study also demonstrated Mobius has better error detectability than conventional measurement-based systems. CONCLUSION Our study shows Mobius3D could be a suitable alternative to conventional measured based QA methods for SRS HyperArc treatments.
Collapse
Affiliation(s)
- Nina Cavalli
- Medical Physics DepartmentHumanitas Istituto Clinico CataneseMisterbiancoCTItaly
| | - Elisa Bonanno
- Medical Physics DepartmentHumanitas Istituto Clinico CataneseMisterbiancoCTItaly
| | - Giuseppina R. Borzì
- Medical Physics DepartmentHumanitas Istituto Clinico CataneseMisterbiancoCTItaly
| | - Alessia D'Anna
- Physics and Astronomy Department E. MajoranaUniversity of CataniaCataniaItaly
| | - Martina Pace
- Medical Physics DepartmentHumanitas Istituto Clinico CataneseMisterbiancoCTItaly
| | - Giuseppe Stella
- Physics and Astronomy Department E. MajoranaUniversity of CataniaCataniaItaly
| | - Lucia Zirone
- Medical Physics DepartmentHumanitas Istituto Clinico CataneseMisterbiancoCTItaly
| | - Carmelo Marino
- Medical Physics DepartmentHumanitas Istituto Clinico CataneseMisterbiancoCTItaly
| |
Collapse
|
7
|
Tarutani K. [Basics of IMRT Dose Verification Methodology and Tolerances: Explanation of AAPM TG-218]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2024; 80:226-232. [PMID: 38382982 DOI: 10.6009/jjrt.2024-2316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Affiliation(s)
- Kazuo Tarutani
- Japan Organization of Occupational Health and Safety Kansai Rosai Hospital
| |
Collapse
|
8
|
Huang Y, Pi Y, Ma K, Miao X, Fu S, Feng A, Duan Y, Kong Q, Zhuo W, Xu Z. Predicting the error magnitude in patient-specific QA during radiotherapy based on ResNet. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2024; 32:797-807. [PMID: 38457139 DOI: 10.3233/xst-230251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/09/2024]
Abstract
BACKGROUND The error magnitude is closely related to patient-specific dosimetry and plays an important role in evaluating the delivery of the radiotherapy plan in QA. No previous study has investigated the feasibility of deep learning to predict error magnitude. OBJECTIVE The purpose of this study was to predict the error magnitude of different delivery error types in radiotherapy based on ResNet. METHODS A total of 34 chest cancer plans (172 fields) of intensity-modulated radiation therapy (IMRT) from Eclipse were selected, of which 30 plans (151 fields) were used for model training and validation, and 4 plans including 21 fields were used for external testing. The collimator misalignment (COLL), monitor unit variation (MU), random multi-leaf collimator shift (MLCR), and systematic MLC shift (MLCS) were introduced. These dose distributions of portal dose predictions for the original plans were defined as the reference dose distribution (RDD), while those for the error-introduced plans were defined as the error-introduced dose distribution (EDD). Different inputs were used in the ResNet for predicting the error magnitude. RESULTS In the test set, the accuracy of error type prediction based on the dose difference, gamma distribution, and RDD + EDD was 98.36%, 98.91%, and 100%, respectively; the root mean squared error (RMSE) was 1.45-1.54, 0.58-0.90, 0.32-0.36, and 0.15-0.24; the mean absolute error (MAE) was 1.06-1.18, 0.32-0.78, 0.25-0.27, and 0.11-0.18, respectively, for COLL, MU, MLCR and MLCS. CONCLUSIONS In this study, error magnitude prediction models with dose difference, gamma distribution, and RDD + EDD are established based on ResNet. The accurate prediction of the error magnitude under different error types can provide reference for error analysis in patient-specific QA.
Collapse
Affiliation(s)
- Ying Huang
- Institute of Modern Physics, Fudan University, Shanghai, China
- Key Laboratory of Nuclear Physics and Ion-Beam Application (MOE), Fudan University, Shanghai, China
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yifei Pi
- Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, Henan, China
| | - Kui Ma
- Varian Medical Systems, Beijing, China
| | - Xiaojuan Miao
- The General Hospital of Western Theater Command PLA, Chengdu, China
| | - Sichao Fu
- The General Hospital of Western Theater Command PLA, Chengdu, China
| | - Aihui Feng
- Institute of Modern Physics, Fudan University, Shanghai, China
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yanhua Duan
- Institute of Modern Physics, Fudan University, Shanghai, China
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Qing Kong
- Institute of Modern Physics, Fudan University, Shanghai, China
| | - Weihai Zhuo
- Key Laboratory of Nuclear Physics and Ion-Beam Application (MOE), Fudan University, Shanghai, China
| | - Zhiyong Xu
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
9
|
Ishizaka N, Kinoshita T, Sakai M, Tanabe S, Nakano H, Tanabe S, Nakamura S, Mayumi K, Akamatsu S, Nishikata T, Takizawa T, Yamada T, Sakai H, Kaidu M, Sasamoto R, Ishikawa H, Utsunomiya S. Prediction of patient-specific quality assurance for volumetric modulated arc therapy using radiomics-based machine learning with dose distribution. J Appl Clin Med Phys 2024; 25:e14215. [PMID: 37987544 PMCID: PMC10795425 DOI: 10.1002/acm2.14215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 09/29/2023] [Accepted: 10/30/2023] [Indexed: 11/22/2023] Open
Abstract
PURPOSE We sought to develop machine learning models to predict the results of patient-specific quality assurance (QA) for volumetric modulated arc therapy (VMAT), which were represented by several dose-evaluation metrics-including the gamma passing rates (GPRs)-and criteria based on the radiomic features of 3D dose distribution in a phantom. METHODS A total of 4,250 radiomic features of 3D dose distribution in a cylindrical dummy phantom for 140 arcs from 106 clinical VMAT plans were extracted. We obtained the following dose-evaluation metrics: GPRs with global and local normalization, the dose difference (DD) in 1% and 2% passing rates (DD1% and DD2%) for 10% and 50% dose threshold, and the distance-to-agreement in 1-mm and 2-mm passing rates (DTA1 mm and DTA2 mm) for 0.5%/mm and 1.0%.mm dose gradient threshold determined by measurement using a diode array in patient-specific QA. The machine learning regression models for predicting the values of the dose-evaluation metrics using the radiomic features were developed based on the elastic net (EN) and extra trees (ET) models. The feature selection and tuning of hyperparameters were performed with nested cross-validation in which four-fold cross-validation is used within the inner loop, and the performance of each model was evaluated in terms of the root mean square error (RMSE), the mean absolute error (MAE), and Spearman's rank correlation coefficient. RESULTS The RMSE and MAE for the developed machine learning models ranged from <1% to nearly <10% depending on the dose-evaluation metric, the criteria, and dose and dose gradient thresholds used for both machine learning models. It was advantageous to focus on high dose region for predicating global GPR, DDs, and DTAs. For certain metrics and criteria, it was possible to create models applicable for patients' heterogeneity by training only with dose distributions in phantom. CONCLUSIONS The developed machine learning models showed high performance for predicting dose-evaluation metrics especially for high dose region depending on the metric and criteria. Our results demonstrate that the radiomic features of dose distribution can be considered good indicators of the plan complexity and useful in predicting measured dose evaluation metrics.
Collapse
Affiliation(s)
- Natsuki Ishizaka
- Department of RadiologyNiigata Prefectural Shibata HospitalShibata CityNiigataJapan
| | - Tomotaka Kinoshita
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
| | - Madoka Sakai
- Department of RadiologyNagaoka Chuo General HospitalNagaokaNiigataJapan
- Department of Radiation OncologyNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Shunpei Tanabe
- Department of Radiation OncologyNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Hisashi Nakano
- Department of Radiation OncologyNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Satoshi Tanabe
- Department of Radiation OncologyNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Sae Nakamura
- Department of Radiation OncologyNiigata Neurosurgical HospitalNiigata CityNiigataJapan
| | - Kazuki Mayumi
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
| | - Shinya Akamatsu
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
- Department of RadiologyTakeda General HospitalAizuwakamatsu CityFukushimaJapan
| | - Takayuki Nishikata
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
- Division of RadiologyNagaoka Red Cross HospitalNagaoka‐shiNiigataJapan
| | - Takeshi Takizawa
- Department of Radiation OncologyNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
- Department of Radiation OncologyNiigata Neurosurgical HospitalNiigata CityNiigataJapan
| | - Takumi Yamada
- Section of Radiology, Department of Clinical SupportNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Hironori Sakai
- Section of Radiology, Department of Clinical SupportNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Motoki Kaidu
- Department of Radiology and Radiation OncologyNiigata University Graduate School of Medical and Dental SciencesNiigata CityNiigataJapan
| | - Ryuta Sasamoto
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation OncologyNiigata University Graduate School of Medical and Dental SciencesNiigata CityNiigataJapan
| | - Satoru Utsunomiya
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
| |
Collapse
|
10
|
Neupane T, Shang C, Kassel M, Muhammad W, Leventouri T, Williams TR. Viability of the virtual cone technique using a fixed small multi-leaf collimator field for stereotactic radiosurgery of trigeminal neuralgia. J Appl Clin Med Phys 2023; 24:e14148. [PMID: 37722766 PMCID: PMC10691631 DOI: 10.1002/acm2.14148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 08/04/2023] [Accepted: 08/20/2023] [Indexed: 09/20/2023] Open
Abstract
Dosimetric uncertainties in very small (≤1.5 × 1.5 cm2 ) photon fields are remarkably higher, which undermines the validity of the virtual cone (VC) technique with a diminutive and variable MLC fields. We evaluate the accuracy and reproducibility of the VC method with a very small, fixed MLC field setting, called a fixed virtual cone (fVC), for small target radiosurgery such as trigeminal neuralgia (TGN). The fVC is characterized by 0.5 cm x 0.5 cm high-definition (HD) MLC field of 10MV FFF beam defined at 100 cm SAD, while backup jaws are positioned at 1.5 cm x 1.5 cm. A spherical dose distribution equivalent to 5 mm (diameter) physical cone was generated using 10-14 non-coplanar, partial arcs. Dosimetric accuracy was validated using SRS diode (PTW 60018), SRS MapCHECK (SNC) measurements. As a quality assurance measure, 10 treatment plans (SRS) for TGN, consisting of various arc ranges at different collimator angles were analyzed using 6 MV FFF and 10 MV FFF beams, including a field-by-field study (n = 130 fields). Dose outputs were compared between the Eclipse TPS and measurements (SRS MapCHECK). Moreover, dosimetric changes in the field defining fVC, prompted by a minute (± 0.5-1.0 mm) leaf shift, was examined among TPS, diode measurements, and Monte Carlo (MC) simulations. The beam model for fVC was validated (≤3% difference) using SRS MapCHECK based absolute dose measurements. The equivalent diameters of the 50% isodose distribution were found comparable to that of a 5 mm cone. Additionally, the comparison of field output factors, dose per MU between the TPS and SRS diode measurements using the fVC field, including ± 1 mm leaf shift, yielded average discrepancies within 5.5% and 3.5% for 6 MV FFF and 10 MV FFF beams, respectively. Overall, the fVC method is a credible alternative to the physical cone (5 mm) that can be applied in routine radiosurgical treatment of TGN.
Collapse
Affiliation(s)
- Taindra Neupane
- Department of PhysicsFlorida Atlantic UniversityBoca RatonFloridaUSA
| | - Charles Shang
- RSOSouth Florida Proton Therapy InstituteDelray BeachFloridaUSA
| | - Maxwell Kassel
- Department of PhysicsFlorida Atlantic UniversityBoca RatonFloridaUSA
| | - Wazir Muhammad
- Department of PhysicsFlorida Atlantic UniversityBoca RatonFloridaUSA
| | - Theodora Leventouri
- Center for Biological and Materials Physics (CBAMP)Department of PhysicsFlorida Atlantic UniversityBoca RatonFloridaUSA
| | - Timothy R. Williams
- Medical DirectorSouth Florida Proton Therapy InstituteDelray BeachFloridaUSA
| |
Collapse
|
11
|
Nakamura S, Sakai M, Ishizaka N, Mayumi K, Kinoshita T, Akamatsu S, Nishikata T, Tanabe S, Nakano H, Tanabe S, Takizawa T, Yamada T, Sakai H, Kaidu M, Sasamoto R, Ishikawa H, Utsunomiya S. Deep learning-based detection and classification of multi-leaf collimator modeling errors in volumetric modulated radiation therapy. J Appl Clin Med Phys 2023; 24:e14136. [PMID: 37633834 PMCID: PMC10691639 DOI: 10.1002/acm2.14136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 08/10/2023] [Accepted: 08/12/2023] [Indexed: 08/28/2023] Open
Abstract
PURPOSE The purpose of this study was to create and evaluate deep learning-based models to detect and classify errors of multi-leaf collimator (MLC) modeling parameters in volumetric modulated radiation therapy (VMAT), namely the transmission factor (TF) and the dosimetric leaf gap (DLG). METHODS A total of 33 clinical VMAT plans for prostate and head-and-neck cancer were used, assuming a cylindrical and homogeneous phantom, and error plans were created by altering the original value of the TF and the DLG by ± 10, 20, and 30% in the treatment planning system (TPS). The Gaussian filters ofσ = 0.5 $\sigma = 0.5$ and 1.0 were applied to the planar dose maps of the error-free plan to mimic the measurement dose map, and thus dose difference maps between the error-free and error plans were obtained. We evaluated 3 deep learning-based models, created to perform the following detections/classifications: (1) error-free versus TF error, (2) error-free versus DLG error, and (3) TF versus DLG error. Models to classify the sign of the errors were also created and evaluated. A gamma analysis was performed for comparison. RESULTS The detection and classification of TF and DLG error were feasible forσ = 0.5 $\sigma = 0.5$ ; however, a considerable reduction of accuracy was observed forσ = 1.0 $\sigma = 1.0$ depending on the magnitude of error and treatment site. The sign of errors was detectable by the specifically trained models forσ = 0.5 $\sigma = 0.5$ and 1.0. The gamma analysis could not detect errors. CONCLUSIONS We demonstrated that the deep learning-based models could feasibly detect and classify TF and DLG errors in VMAT dose distributions, depending on the magnitude of the error, treatment site, and the degree of mimicked measurement doses.
Collapse
Affiliation(s)
- Sae Nakamura
- Department of Radiation OncologyNiigata Neurosurgical Hospital, Nishi‐kuNiigata CityNiigataJapan
| | - Madoka Sakai
- Department of RadiologyNagaoka Chuo General Hospital, NagaokaNagaokaNiigataJapan
- Department of Radiology and Radiation OncologyNiigata University Graduate School of Medical and Dental Sciences, Chuo‐kuNiigata CityNiigataJapan
| | - Natsuki Ishizaka
- Department of RadiologyNiigata Prefectural Shibata HospitalShibata CityNiigataJapan
| | - Kazuki Mayumi
- Department of Radiological TechnologyNiigata University Graduate School of Health Sciences, Chuo‐kuNiigata CityNiigataJapan
| | - Tomotaka Kinoshita
- Department of Radiological TechnologyNiigata University Graduate School of Health Sciences, Chuo‐kuNiigata CityNiigataJapan
| | - Shinya Akamatsu
- Department of Radiological TechnologyNiigata University Graduate School of Health Sciences, Chuo‐kuNiigata CityNiigataJapan
- Department of RadiologyTakeda General Hospital, Aizuwakamatu CityFukushimaJapan
| | - Takayuki Nishikata
- Department of Radiological TechnologyNiigata University Graduate School of Health Sciences, Chuo‐kuNiigata CityNiigataJapan
- Division of RadiologyNagaoka Red Cross HospitalNagaoka CityNiigataJapan
| | - Shunpei Tanabe
- Department of Radiation OncologyNiigata University Medical and Dental Hospital, Chuo‐kuNiigata CityNiigataJapan
| | - Hisashi Nakano
- Department of Radiation OncologyNiigata University Medical and Dental Hospital, Chuo‐kuNiigata CityNiigataJapan
| | - Satoshi Tanabe
- Department of Radiation OncologyNiigata University Medical and Dental Hospital, Chuo‐kuNiigata CityNiigataJapan
| | - Takeshi Takizawa
- Department of Radiation OncologyNiigata Neurosurgical Hospital, Nishi‐kuNiigata CityNiigataJapan
- Department of Radiology and Radiation OncologyNiigata University Graduate School of Medical and Dental Sciences, Chuo‐kuNiigata CityNiigataJapan
| | - Takumi Yamada
- Section of RadiologyDepartment of Clinical SupportNiigata University Medical and Dental Hospital, Chuo‐kuNiigata CityNiigataJapan
| | - Hironori Sakai
- Section of RadiologyDepartment of Clinical SupportNiigata University Medical and Dental Hospital, Chuo‐kuNiigata CityNiigataJapan
| | - Motoki Kaidu
- Department of Radiology and Radiation OncologyNiigata University Graduate School of Medical and Dental Sciences, Chuo‐kuNiigata CityNiigataJapan
| | - Ryuta Sasamoto
- Department of Radiological TechnologyNiigata University Graduate School of Health Sciences, Chuo‐kuNiigata CityNiigataJapan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation OncologyNiigata University Graduate School of Medical and Dental Sciences, Chuo‐kuNiigata CityNiigataJapan
| | - Satoru Utsunomiya
- Department of Radiological TechnologyNiigata University Graduate School of Health Sciences, Chuo‐kuNiigata CityNiigataJapan
| |
Collapse
|
12
|
Labagnoy YJM, Oonsiri S, Vimolnoch M, Kingkaew S. Assessment of the Dosimetric Performance of the Mobius3D against Portal Dose Measurements in Patient-specific Quality Assurance. J Med Phys 2023; 48:350-357. [PMID: 38223801 PMCID: PMC10783182 DOI: 10.4103/jmp.jmp_19_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 08/09/2023] [Accepted: 08/14/2023] [Indexed: 01/16/2024] Open
Abstract
Aim The Mobius3D software addresses limitations lacking in measurement-based methods in patient-specific quality assurance (QA). The objective of this study was to validate its dosimetric performance against conventionally used portal dose measurements using gamma analysis and confidence limits. Materials and Methods A total of 240 patient-specific QA plans for the Varian Halcyon linear accelerator were collected. The Mobius3D software was commissioned through beam data and plan verification. All plans underwent QA through the electronic portal imaging device, coupled with the Portal Dosimetry software, and the Mobius3D. Data were assessed using >95% gamma pass. Portal measurements were evaluated using 3%/2 mm and 3%/3 mm criteria, whereas Mobius3D was analyzed at 3%/3 mm and 5%/3 mm, at the 10% threshold. Results Mobius 5%/3 mm mean gamma passes were 99.89% for volumetric-modulated arc therapy (VMAT) and 99.31% for intensity-modulated radiotherapy (IMRT), and correspondingly, the data for portal 3%/2 mm were 99.99% and 99.96%. The Mobius3D at 5%/3 mm can perform like Portal 3%/2 mm for VMAT plans at 0.1% difference, especially for head/neck and pelvic/abdominal cases. In IMRT-based treatments, at 0.7% difference in Mobius3D 5%/3 mm and Portal 3%/2 mm, the performance and error identification in IMRT plans should be applied more carefully due to the amount of failed plans, particularly the chest region. The confidence limits for VMAT plans for Portal 3%/2 mm and Mobius 5%/3 mm are 99.93% and 99.42%, respectively, while for IMRT plans are 99.69% and 97.43%, respectively. Conclusions At a 5%/3 mm criterion, the Mobius3D may yield percentage gamma pass rates like measurements obtained by Portal Dosimetry 3%/3 mm and Portal Dosimetry 3%/2 mm. As the software is largely dependent on commissioned data, rigorous commissioning and a comprehensive QA program should be implemented.
Collapse
Affiliation(s)
| | - Sornjarod Oonsiri
- Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Mananchaya Vimolnoch
- Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Sakda Kingkaew
- Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| |
Collapse
|
13
|
Maeyama T, Hayashi K, Watanabe Y, Ohara M, Nakagawa S. Development of a silicone-based radio-fluorogenic dosimeter using dihydrorhodamine 6G. Phys Med 2023; 114:102684. [PMID: 37778206 DOI: 10.1016/j.ejmp.2023.102684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 07/24/2023] [Accepted: 09/11/2023] [Indexed: 10/03/2023] Open
Abstract
A silicon-based three-dimensional dosimeter can be formed in a free shape without a container and deformed because of its flexibility. Several studies have focused on enhancing its radiological characteristics and assessing its applicability as a quality assurance tool for image-guided and adaptive radiation therapy, considering motion and deformation. Here, we applied a fluorescence probe (dihydrorhodamine 6G, DHR6G) to a silicon elastomer as a new radiosensitive compound that converts nonfluorescent into fluorescent dyes using irradiation, and its fluorescence intensity increases linearly with the absorbed dose. In this study, we demonstrated a cost-effective synthesis method and optimized the composition conditions. The results showed that the DHR6G-SE prepared from 2.2 × 10-3 wt% DHR6G, 0.024 wt% pyridine, and a silicone elastomer (SE) (SILPOT TM 184, base/curing agent = 10/1) exhibited a linear increase in fluorescence with radiation exposure within a dose range of 0-8 Gy and a highly stable sensitivity for as long as 64 h. To demonstrate its container-less characteristics, the possibility of dosimetry for low-energy X-rays using DHR6G-SE was investigated.
Collapse
Affiliation(s)
- Takuya Maeyama
- Department of Chemistry, School of Science, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0373, Japan; RIKEN Nishina Center for Accelerator-Based Science, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan.
| | - Kiichiro Hayashi
- Department of Chemistry, School of Science, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0373, Japan
| | - Yusuke Watanabe
- School of Allied Health Sciences, Kitasato University, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa 252-0373, Japan
| | - Maki Ohara
- National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba-City, Chiba 263-8555, Japan
| | - Seiko Nakagawa
- Tokyo Metropolitan Industrial Technology Research Institute, 2-4-10 Aomi, Koto-ku, Tokyo 135-0064, Japan
| |
Collapse
|
14
|
Rousseau A, Stien C, Gouriou J, Bordy JM, Boissonnat G, Chabert I, Dufreneix S, Blideanu V. End-to-end quality assurance for stereotactic radiotherapy with Fricke-Xylenol orange-Gelatin gel dosimeter and dual-wavelength cone-beam optical CT readout. Phys Med 2023; 113:102656. [PMID: 37625218 DOI: 10.1016/j.ejmp.2023.102656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 06/04/2023] [Accepted: 08/05/2023] [Indexed: 08/27/2023] Open
Abstract
PURPOSE The end-to-end (E2E) quality assurance (QA) test is a unique tool for validating the treatment chain undergone by patients in external radiotherapy. It should be conducted in three dimensions (3D) to get accurate results. This study aims to implement these tests with Fricke-Xylenol orange-Gelatin (FXG) gel dosimeter and a newly developed dual-wavelength reading method on the Vista16™ optical Computed Tomography (CT) scanner (ModusQA) for three treatment techniques in stereotactic radiotherapy, on Novalis (Varian) and CyberKnife (Accuray) linear accelerators. METHODS The tests were performed in head phantoms. Gel measurements were compared with planned dose distributions and measured by film and ion chamber measurements by plotting isodose curves and dose profiles, and by conducting a 3D local gamma-index analysis (2%/2mm criteria). RESULTS Gamma passing rates were higher than 95 %. Point dose differences between treatment planning and gel and ion chamber measurements at the isocenter were < 2.3 % for both treatments delivered on the Novalis accelerator, while this difference was higher than 4 % for the treatment delivered on the CyberKnife, highlighting a small overdosing of the tumor volume. A good agreement was observed between gel and film dose profiles. CONCLUSIONS This study presents the successful implementation of 3D E2E QA tests for stereotactic radiotherapy with FXG gel dosimetry and a dual-wavelength reading method on an optical CT scanner. This dosimetric method provides 3D absolute dose distributions in the 0.25 - 10 Gy dose range with a high spatial resolution and a dose uncertainty of around 2 % (k=1).
Collapse
Affiliation(s)
- Alice Rousseau
- Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), Palaiseau, France.
| | - Christel Stien
- Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), Palaiseau, France
| | - Jean Gouriou
- Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), Palaiseau, France
| | - Jean-Marc Bordy
- Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), Palaiseau, France
| | - Guillaume Boissonnat
- Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), Palaiseau, France
| | | | - Stéphane Dufreneix
- Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), Palaiseau, France; Institut de Cancérologie de l'Ouest, Angers, France
| | - Valentin Blideanu
- Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), Palaiseau, France
| |
Collapse
|
15
|
Sheen H, Shin HB, Kim H, Kim C, Kim J, Kim JS, Hong CS. Application of error classification model using indices based on dose distribution for characteristics evaluation of multileaf collimator position errors. Sci Rep 2023; 13:11027. [PMID: 37419940 PMCID: PMC10328946 DOI: 10.1038/s41598-023-35570-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 05/20/2023] [Indexed: 07/09/2023] Open
Abstract
This study aims to evaluate the specific characteristics of various multileaf collimator (MLC) position errors that are correlated with the indices using dose distribution. The dose distribution was investigated using the gamma, structural similarity, and dosiomics indices. Cases from the American Association of Physicists in Medicine Task Group 119 were planned, and systematic and random MLC position errors were simulated. The indices were obtained from distribution maps and statistically significant indices were selected. The final model was determined when all values of the area under the curve, accuracy, precision, sensitivity, and specificity were higher than 0.8 (p < 0.05). The dose-volume histogram (DVH) relative percentage difference between the error-free and error datasets was examined to investigate clinical relations. Seven multivariate predictive models were finalized. The common significant dosiomics indices (GLCM Energy and GLRLM_LRHGE) can characterize the MLC position error. In addition, the finalized logistic regression model for MLC position error prediction showed excellent performance with AUC > 0.9. Furthermore, the results of the DVH were related to dosiomics analysis in that it reflects the characteristics of the MLC position error. It was also shown that dosiomics analysis could provide important information on localized dose-distribution differences in addition to DVH information.
Collapse
Affiliation(s)
- Heesoon Sheen
- Department of Health Sciences and Technology, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul, South Korea
| | - Han-Back Shin
- Department of Radiation Oncology, Gachon University Gil Medical Center, Incheon, South Korea
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Hojae Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Seoul, South Korea
| | - Changhwan Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Jihun Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Jin Sung Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Chae-Seon Hong
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea.
| |
Collapse
|
16
|
Sidhu MS, Singh K, Sood S, Aggarwal R. A dosimetric comparison of intensity-modulated radiotherapy versus rapid arc in gynecological malignancies: Dose beyond planning target volume, precisely 5Gy volume. J Cancer Res Ther 2023; 19:1267-1271. [PMID: 37787294 DOI: 10.4103/jcrt.jcrt_11_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
Introduction Aim of radiotherapy is precise dose delivery with objective of achieving maximum local control and minimal toxicity by decreasing dose to organ at risk (OAR).This aim can be achieved by technologies like intensity-modulated radiotherapy (IMRT) and volumetric arc therapy. However, later offers comparable or even better plan quality with shorter treatment time. It is important to note that low dose regions are also a concern due long-term risk of developing a second cancer after radiotherapy. The objective of our study is to do dosimetric comparison of IMRT vs. Rapid arc (RA) plan in gynecology cancer and specifically to assess dose beyond planning target volume (PTV), precisely 5 Gy volume. Methods Each 20 eligible patients underwent radiotherapy planning on eclipse by both IMRT and RA plans as per institution protocols. Comparative dosimetric analysis of both plans was done by paired sample t-test. PTV metrics compared were D95%, homogenecity index (HI), and conformity index (CI). OAR dose compared were bowel V40 Gy <30%, Rectum V30 Gy <60%, Bladder V45 Gy <35%, and bilateral femur head and neck V30 Gy < 50%. Futhermore, calculated monitor units (MUs) were also compared. Finally, volume of normal tissue beyond the PTV, specifically 5 Gy volume, was compared between plans. Results Dosimetric plan comparison showed statistically significant difference in RA and IMRT plans with improved PTV coverage and better OAR tolerance with RA plan. In addition, MU used were significantly less in RA plan, coupled with reduced V5 Gy volume. Conclusion In sum, RA plans are dosimetrically significantly better compared to IMRT plans in gynecological malignancies in terms of PTV coverage and OAR sparing. Importantly, not only less MU used but also significantly less normal tissue V5 Gy volume is less in RA compared to IMRT plans.
Collapse
Affiliation(s)
| | - Kulbir Singh
- Department of Medical Physics, DMCH Cancer Centre, Ludhiana, Punjab, India
| | - Sandhya Sood
- Department of Radiation Oncology, DMCH Cancer Centre, Ludhiana, Punjab, India
| | - Ritu Aggarwal
- Department of Radiation Oncology, DMCH Cancer Centre, Ludhiana, Punjab, India
| |
Collapse
|
17
|
Gasparian PB, Malthez AL, Torquato M, Campos LL. Radiosurgery dosimetry using CaSO4:Eu OSLD film-a feasibility study. RADIATION PROTECTION DOSIMETRY 2023; 199:1040-1046. [PMID: 37225215 DOI: 10.1093/rpd/ncad109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Recent studies demonstrated that optically stimulated luminescence (OSL) systems allow the evaluation of doses for 2D mapping in a relatively fast and simple way and results show submillimeter resolution. This work presents, for the first time, an optically stimulated luminescence dosemeter (OSLD) in the form of film made with CaSO4:Eu particles embedded in a silicone elastomer matrix. The OSLD film was produced using a low-cost and relatively simple methodology. This film is reusable and the signal can be satisfactorily bleached using blue LEDs. The main dosimetric properties were evaluated using TL/OSL Risø reader with blue stimulation and Hoya U-340 filter. Investigation shows repeatability within 3% when measuring with the same film sample. Regarding the OSLD film homogeneity, nearly 12% sensitivity change was observed within the 5 × 5 cm2 produced film. Additionally, the dose response curve shows linearity from 5 to 25 Gy. Fading of the OSL signal is relatively high, about 50% in the first week and then is stable. Nevertheless, a 3 × 3 cm2 OSLD film was successfully used to map dose distribution in radiosurgery (6 MV photon beam). This work demonstrates the feasibility of 2D dosimetry using reusable OSLD films based on CaSO4:Eu.
Collapse
Affiliation(s)
- Patricia Br Gasparian
- Comissão Nacional de Energia Nuclear-CNEN, Rio de Janeiro, Brazil
- Instituto de Pesquisas Energéticas e Nucleares-IPEN/CNEN, São Paulo, Brazil
| | | | | | - Leticia L Campos
- Instituto de Pesquisas Energéticas e Nucleares-IPEN/CNEN, São Paulo, Brazil
| |
Collapse
|
18
|
Huang Y, Pi Y, Ma K, Miao X, Fu S, Chen H, Wang H, Gu H, Shao Y, Duan Y, Feng A, Zhuo W, Xu Z. Image-based features in machine learning to identify delivery errors and predict error magnitude for patient-specific IMRT quality assurance. Strahlenther Onkol 2023; 199:498-510. [PMID: 36988665 PMCID: PMC10133379 DOI: 10.1007/s00066-023-02076-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 03/05/2023] [Indexed: 03/30/2023]
Abstract
OBJECTIVE To identify delivery error type and predict associated error magnitude by image-based features using machine learning (ML). METHODS In this study, a total of 40 thoracic plans (including 208 beams) were selected, and four error types with different magnitudes were introduced into the original plans, including 1) collimator misalignment (COLL), 2) monitor unit (MU) variation, 3) systematic multileaf collimator misalignment (MLCS), and 4) random MLC misalignment (MLCR). These dose distributions of portal dose predictions for the original plans were defined as the reference dose distributions (RDD), while those for the error-introduced plans were defined as the error-introduced dose distributions (EDD). Both distributions were calculated for all beams with portal dose image prediction (PDIP). Besides, 14 image-based features were extracted from RDD and EDD of portal dose predictions to obtain the feature vectors. In addition, a random forest was adopted for the multiclass classification task, and regression prediction for error magnitude. RESULTS The top five features extracted with the highest weight included 1) the relative displacement in the x direction, 2) the ratio of the absolute minimum residual error to the maximal RDD value, 3) the product of the maximum and minimum residuals, 4) the ratio of the absolute maximum residual error to the maximal RDD value, and 5) the ratio of the absolute mean residual value to the maximal RDD value. The relative displacement in the x direction had the highest weight. The overall accuracy of the five-class classification model was 99.85% for the validation set and 99.30% for the testing set. This model could be applied to the classification of the error-free plan, COLL, MU, MLCS, and MLCR with an accuracy of 100%, 98.4%, 99.9%, 98.0%, and 98.3%, respectively. MLCR had the worst performance in error magnitude prediction (70.1-96.6%), while others had better performance in error magnitude prediction (higher than 93%). In the error magnitude prediction, the mean absolute error (MAE) between predicted error magnitude and actual error ranged from 0.03 to 0.33, with the root mean squared error (RMSE) varying from 0.17 to 0.56 for the validation set. The MAE and RMSE ranged from 0.03 to 0.50 and 0.44 to 0.59 for the test set, respectively. CONCLUSION It could be demonstrated in this study that the image-based features extracted from RDD and EDD can be employed to identify different types of delivery errors and accurately predict error magnitude with the assistance of ML techniques. They can be used to associate traditional gamma analysis with clinically based analysis for error classification and magnitude prediction in patient-specific IMRT quality assurance.
Collapse
Affiliation(s)
- Ying Huang
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, 200030, Shanghai, China
| | - Yifei Pi
- Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, Henan, China
| | - Kui Ma
- Varian Medical Systems No.8 Yun Cheng Street, Beijing, China
| | - Xiaojuan Miao
- The General Hospital of Western Theater Command PLA, Chengdu, China
| | - Sichao Fu
- The General Hospital of Western Theater Command PLA, Chengdu, China
| | - Hua Chen
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, 200030, Shanghai, China
| | - Hao Wang
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, 200030, Shanghai, China
| | - Hengle Gu
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, 200030, Shanghai, China
| | - Yan Shao
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, 200030, Shanghai, China
| | - Yanhua Duan
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, 200030, Shanghai, China
| | - Aihui Feng
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, 200030, Shanghai, China
| | - Weihai Zhuo
- Key Lab of Nucl. Phys. & Ion-Beam Appl. (MOE), Fudan University, Shanghai, China.
| | - Zhiyong Xu
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, 200030, Shanghai, China.
| |
Collapse
|
19
|
Matsumoto K, Maruyama A, Watanabe S, Tachibana R, Yamaguchi T, Suzuki K, Kurihara Y, Maehara M, Arakawa S, Hosokai Y. Characteristics of a real-time radiation exposure dosimetry system using a synthetic ruby for radiotherapy. Radiol Phys Technol 2023; 16:69-76. [PMID: 36508129 DOI: 10.1007/s12194-022-00691-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 12/05/2022] [Accepted: 12/06/2022] [Indexed: 12/14/2022]
Abstract
Radiotherapy-related medical accidents are frequently caused by planning problems, excessive irradiation during radiotherapy, or patient movement. This is partly because the local exposure dose cannot be directly monitored during radiotherapy. This article discusses the development of our recent real-time radiation exposure dosimetry system that uses a synthetic ruby for radiation therapy. Background noise was observed before the measurement of the short-term characteristic features. Regarding the relationship between the number of photons and dose rate, using 100 monitor units (MU)/min as the measurement value, the counts decreased by approximately 10% at 600 MU/min. A clear correlation was observed between the MU value and the number of photons (R2 = 0.9987). The coefficient of variation (%CV) was less than ± 1.0% under all the irradiation conditions. Slight differences were observed between the ion chamber and the synthetic ruby dosimeters in the measurement of the percentage depth dose. However, this difference was almost matched by correcting for the Cherenkov light. Although some problems were observed with the synthetic ruby dosimeter system, our results indicate that the developed dosimeter can be used to measure the irradiation dose of patients in real time, with no significant impact on the data, as any effect would be masked by the larger effect of the ruby; however, the impact requires a detailed assessment in the future.
Collapse
Affiliation(s)
- Kenki Matsumoto
- School of Health Sciences, Department of Radiological Sciences, International University of Health and Welfare, 2600-1, Kitakanemaru, Otawara, , Tochigi, 324-8501, Japan
| | - Ayaka Maruyama
- School of Health Sciences, Department of Radiological Sciences, International University of Health and Welfare, 2600-1, Kitakanemaru, Otawara, , Tochigi, 324-8501, Japan
| | - Satoru Watanabe
- South Miyagi Medical Center, Shibata, Miyagi, 989-1253, Japan
| | - Ryousuke Tachibana
- School of Health Sciences, Department of Radiological Sciences, International University of Health and Welfare, 2600-1, Kitakanemaru, Otawara, , Tochigi, 324-8501, Japan
| | - Toshiya Yamaguchi
- School of Health Sciences, Department of Radiological Sciences, International University of Health and Welfare, 2600-1, Kitakanemaru, Otawara, , Tochigi, 324-8501, Japan
| | - Kouki Suzuki
- School of Health Sciences, Department of Radiological Sciences, International University of Health and Welfare, 2600-1, Kitakanemaru, Otawara, , Tochigi, 324-8501, Japan
| | - Yoshiki Kurihara
- School of Health Sciences, Department of Radiological Sciences, International University of Health and Welfare, 2600-1, Kitakanemaru, Otawara, , Tochigi, 324-8501, Japan
| | - Masayoshi Maehara
- School of Health Sciences, Department of Radiological Sciences, International University of Health and Welfare, 2600-1, Kitakanemaru, Otawara, , Tochigi, 324-8501, Japan
| | - Satoshi Arakawa
- School of Health Sciences, Department of Radiological Sciences, International University of Health and Welfare, 2600-1, Kitakanemaru, Otawara, , Tochigi, 324-8501, Japan
| | - Yoshiyuki Hosokai
- School of Health Sciences, Department of Radiological Sciences, International University of Health and Welfare, 2600-1, Kitakanemaru, Otawara, , Tochigi, 324-8501, Japan.
| |
Collapse
|
20
|
Gedam VR, Pradhan A. EVALUATION OF PATIENT-SPECIFIC IMRT QUALITY ASSURANCE AND POINT DOSE MEASUREMENT FOR COMPLEX HEAD AND NECK AND BRAIN CANCER USING GAFCHROMIC EBT3 FILM. RADIATION PROTECTION DOSIMETRY 2023; 199:164-170. [PMID: 36515393 DOI: 10.1093/rpd/ncac250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 09/13/2022] [Accepted: 11/04/2022] [Indexed: 06/17/2023]
Abstract
Patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) is essential for complex radiotherapy treatment as it involves complex intensity modulation and high-dose gradient regions. IMRT QA was performed by point dose verification and two-dimensional (2D) dose distribution measurement using gamma method. Calibrated External Beam Therapy 3 (EBT3) film was used for point dose and pre-treatment verification of 10 IMRT plans, five complex Head and Neck (HN) and five brain cases. The gamma passing rate (GPR) was evaluated for 3%/3 mm gamma criteria and compared with 2D array. Isocentre dose was measured for all 10 IMRT plans on EBT3 film. Percentage deviation of point dose measurement from TPS calculated was found 0.4% for brain cases and 2.9% for HN cases. The GPR for 3%/3 mm criteria was obtained higher than 95% for brain and HN cases. Results suggest that film dosimetry is also a reliable verification system for patient-specific IMRT QA as the 2D array.
Collapse
Affiliation(s)
- Varsha R Gedam
- Department of Medical Physics, Delhi State Cancer Institute, Dilshad Garden 110095, Delhi, India
- Department of Physics, GLA University, Mathura 281406, Uttar Pradesh, India
| | - Anirudh Pradhan
- Centre for Cosmology, Astrophysics, and Space Science, GLA University, Mathura 281406, Uttar Pradesh, India
| |
Collapse
|
21
|
Caprioli M, Delombaerde L, De Saint-Hubert M, de Freitas Nascimento L, De Roover R, Himschoot K, van der Heyden B, Vandenbroucke D, Leblans P, Crijns W. Calibration and time fading characterization of a new optically stimulated luminescence film dosimeter. Med Phys 2023; 50:1185-1193. [PMID: 36353946 DOI: 10.1002/mp.16076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 10/14/2022] [Accepted: 10/20/2022] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Optically stimulated luminescence (OSL) dosimeters produce a signal linear to the dose, which fades with time due to the spontaneous recombination of energetically unstable electron/hole traps. When used for radiotherapy (RT) applications, fading affects the signal-to-dose conversion and causes an error in the final dose measurement. Moreover, the signal fading depends to some extent on treatment-specific irradiation conditions such as irradiation times. PURPOSE In this work, a dose calibration function for a novel OSL film dosimeter was derived accounting for signal fading. The proposed calibration allows to perform dosimetry evaluation for different RT treatment regimes. METHODS A novel BaFBr:Eu2+ -based OSL film (Zeff , 6 MV = 4.7) was irradiated on a TrueBeam STx using a 6 MV beam with setup: 0° gantry angle, 90 cm SSD, 10 cm depth, 10 × 10 cm2 field. A total of 86 measurements were acquired for dose-rates ( D ̇ $\dot{D}$ ) of 600, 300, and 200 MU/min for irradiation times (tir ) of 0.2, 1, 2, 4.5, 12, and 23 min and various readout times (tscan ) between 4 and 1440 min from the start of the exposure (beam-on time). The OSL signal, S ( D ̇ , t i r , t s c a n ) $S(\dot{D},{t}_{ir},{t}_{scan})$ , was modeled via robust nonlinear regression, and two different power-law fading models were tested, respectively, independent (linear model) and dependent on the specific t i r ${t}_{ir}$ (delivery-dependent model). RESULTS After 1 day from the exposure, the error on the dose measurement can be as high as 48% if a fading correction is not considered. The fading contribution was characterized by two accurate models with adjusted-R2 of 0.99. The difference between the two models is <4.75% for all t i r ${t}_{ir}$ and t s c a n ${t}_{scan}$ . For different beam-on times, 3, 10.5, and 20 min, the optimum t s c a n ${t}_{scan}$ was calculated in order to achieve a signal-to-dose conversion with a model-related error <1%. In the case of a 3 min irradiation, this condition is already met when the OSL-film is scanned immediately after the end of the irradiation. For an irradiation of 10.5 and 20 min, the minimum scanning time to achieve this model-related error increases, respectively, to 30 and 90 min. Under these conditions, the linear model can be used for the signal-to-dose conversion as an approximation of the delivery-dependent model. The signal-to-dose function, D(Mi , j , t s c a n $\ {t}_{scan}$ ), has a residual mean error of 0.016, which gives a residual dose uncertainty of 0.5 mGy in the region of steep signal fading (i.e., t s c a n ${t}_{scan}\ $ = 4 min). The function of two variables is representable as a dose surface depending on the signal (Mi , j ) measured for each i,j-pixel and the time of scan ( t s c a n ${t}_{scan}$ ). CONCLUSIONS The calibration of a novel OSL-film usable for dosimetry in different RT treatments was corrected for its signal fading with two different models. A linear calibration model independent from the treatment-specific irradiation condition results in a model-related error <1% if a proper scanning time is used for each irradiation length. This model is more practical than the delivery-dependent model because it does not need a pixel-to-pixel fading correction for different t i r ${t}_{ir}$ .
Collapse
Affiliation(s)
- Marco Caprioli
- Department of Radiation Oncology, KU Leuven, Leuven, Belgium
| | | | - Marijke De Saint-Hubert
- Research in Dosimetric Application group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | | | - Robin De Roover
- Department of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium
| | | | - Brent van der Heyden
- Research in Dosimetric Application group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | | | - Paul Leblans
- Corporate Innovation Office, Agfa N.V., Mortsel, Belgium
| | - Wouter Crijns
- Department of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium
| |
Collapse
|
22
|
Small field output factor measurement and verification for CyberKnife robotic radiotherapy and radiosurgery system using 3D polymer gel, ionization chamber, diode, diamond and scintillator detectors, Gafchromic film and Monte Carlo simulation. Appl Radiat Isot 2023; 192:110576. [PMID: 36473319 DOI: 10.1016/j.apradiso.2022.110576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 11/19/2022] [Accepted: 11/21/2022] [Indexed: 11/24/2022]
Abstract
The dosimetry of small fields has become tremendously important with the advent of intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery, where small field segments or very small fields are used to treat tumors. With high dose gradients in the stereotactic radiosurgery or radiotherapy treatment, small field dosimetry becomes challenging due to the lack of lateral electronic equilibrium in the field, x-ray source occlusion, and detector volume averaging. Small volume and tissue-equivalent detectors are recommended to overcome the challenges. With the lack of a perfect radiation detector, studies on available detectors are ongoing with reasonable disagreement and uncertainties. The joint IAEA and AAPM international code of practice (CoP) for small field dosimetry, TRS 483 (Alfonso et al., 2017) provides guidelines and recommendations for the dosimetry of small static fields in external beam radiotherapy. The CoP provides a methodology for field output factor (FOF) measurements and use of field output correction factors for a series of small field detectors and strongly recommends additional measurements, data collection and verification for CyberKnife (CK) robotic stereotactic radiotherapy/radiosurgery system using the listed detectors and more new detectors so that the FOFs can be implemented clinically. The present investigation is focused on using 3D gel along with some other commercially available detectors for the measurement and verification of field output factors (FOFs) for the small fields available in the CK system. The FOF verification was performed through a comparison with published data and Monte Carlo simulation. The results of this study have proved the suitability of an in-house developed 3D polymer gel dosimeter, several commercially available detectors, and Gafchromic films as a part of small field dosimetric measurements for the CK system.
Collapse
|
23
|
Andersson P, Swanpalmer J, Palm Å, Båth M, Chakarova R. Cylindrical ionization chamber response in static and dynamic 6 and 15 MV photon beams. Biomed Phys Eng Express 2023; 9. [PMID: 36689763 DOI: 10.1088/2057-1976/acb553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 01/23/2023] [Indexed: 01/24/2023]
Abstract
Purpose.To investigate the response of the CC13 ionization chamber under non-reference photon beam conditions, focusing on penumbra and build-up regions of static fields and on dynamic intensity-modulated beams.Methods. Measurements were performed in 6 MV 100 × 100, 20 × 100, and 20 × 20 mm2static fields. Monte Carlo calculations were performed for the static fields and for 6 and 15 MV dynamic beam sequences using a Varian multi-leaf collimator. The chamber was modelled using EGSnrc egs_chamber software. Conversion factors were calculated by relating the absorbed dose to air in the chamber air cavity to the absorbed dose to water. Correction and point-dose correction factors were calculated to quantify the conversion factor variations.Results. The correction factors for positions on the beam central axis and at the penumbra centre were 0.98-1.02 for all static fields and depths investigated. The largest corrections were obtained for chamber positions beyond penumbra centre in the off-axis direction. Point-dose correction factors were 0.54-0.71 at 100 mm depth and their magnitude increased with decreasing field size and measurement depth. Factors of 0.99-1.03 were obtained inside and near the integrated penumbra of the dynamic field at 100 mm depth, and of 0.92-0.94 beyond the integrated penumbra centre. The variations in the ionization chamber response across the integrated dynamic penumbra qualitatively followed the behaviour across penumbra of static fields.Conclusions. Without corrections, the CC13 chamber was of limited usefulness for profile measurements in 20-mm-wide fields. However, measurements in dynamic small irregular beam openings resembling the conditions of pre-treatment patient quality assurance were feasible. Uncorrected ionization chamber response could be applied for dose verification at 100 mm depth inside and close to large gradients of dynamically accumulating high- and low-dose regions assuming 3% tolerance between measured and calculated doses.
Collapse
Affiliation(s)
- P Andersson
- Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, University of Gothenburg, Gothenburg, Sweden.,RISE Research Institutes of Sweden, Materials and Production, Gothenburg, Sweden
| | - J Swanpalmer
- Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, University of Gothenburg, Gothenburg, Sweden.,Sahlgrenska University Hospital, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Å Palm
- Sahlgrenska University Hospital, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - M Båth
- Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, University of Gothenburg, Gothenburg, Sweden.,Sahlgrenska University Hospital, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - R Chakarova
- Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, University of Gothenburg, Gothenburg, Sweden.,Sahlgrenska University Hospital, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
24
|
Valdetaro LB, Jensen MB, Muren LP, Skyt PS, Petersen JBB, Balling P. Technical note: Temporal and thermal stability of optical response for silicone-based 3D radiochromic dosimeters. Med Phys 2022; 50:2560-2564. [PMID: 36585852 DOI: 10.1002/mp.16193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 11/28/2022] [Accepted: 12/13/2022] [Indexed: 01/01/2023] Open
Abstract
BACKGROUND Radiochromic silicone-based dosimeters are flexible 3D dosimeters, which at appropriate concentration of leucomalachite green (LMG) and curing agent are dose-rate independent for clinical photon beams. However, their dose response is based on chemical processes that can be influenced by temporal and thermal conditions, impacting measurement stability. PURPOSE The aim of this study was to investigate the temporal stability of the dose response of radiochromic dosimeters for different curing times and post-irradiation storage temperatures. METHODS Six cylindrical dosimeters (5 cm diameter, 5 cm length) were produced in a single batch and separated into two groups that were irradiated 72 and 118 h after production. The same photon plan, consisting of two 10 × 1.6 cm2 opposing fields, was delivered to all dosimeters. After irradiation, the dosimeters were separated into three groups, stored at 5°C, 15°C, and 20°C, and read out for five consecutive days. RESULTS Storage temperature influenced the measurement stability, and changes in the optical response with time differed between irradiated and non-irradiated parts of the dosimeters. The relative change between signal and background was greater than 10% for all measurements performed 24 h or more after irradiation, except for dosimeters stored at 5°C, which changed by 2%-5% after 24 h. The dosimeter temporal stability was not influenced by curing time. CONCLUSIONS For room temperature storage (15°C and 20°C), readout should take place as soon as possible after irradiation since the background color increased rapidly for both curing times (72 and 118 h), whereas the dosimeters are stored at 5°C, readout can be performed up to 24 h after.
Collapse
Affiliation(s)
- Lia Barbosa Valdetaro
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Morten Bjørn Jensen
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | - Ludvig Paul Muren
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | | | - Jørgen Breede Baltzer Petersen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | - Peter Balling
- Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark.,Interdisciplinary Nanoscience Center, Aarhus University, Aarhus, Denmark
| |
Collapse
|
25
|
Zhao X, Stanley DN, Cardenas CE, Harms J, Popple RA. Do we need patient-specific QA for adaptively generated plans? Retrospective evaluation of delivered online adaptive treatment plans on Varian Ethos. J Appl Clin Med Phys 2022; 24:e13876. [PMID: 36560887 PMCID: PMC9924122 DOI: 10.1002/acm2.13876] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 11/09/2022] [Accepted: 11/15/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND The clinical introduction of dedicated treatment units for online adaptive radiation therapy (OART) has led to widespread adoption of daily adaptive radiotherapy. OART allows for rapid generation of treatment plans using daily patient anatomy, potentially leading to reduction of treatment margins and increased normal tissue sparing. However, the OART workflow does not allow for measurement of patient-specific quality assurance (PSQA) during treatment delivery sessions and instead relies on secondary dose calculations for verification of adapted plans. It remains unknown if independent dose verification is a sufficient surrogate for PSQA measurements. PURPOSE To evaluate the plan quality of previously treated adaptive plans through multiple standard PSQA measurements. METHODS This IRB-approved retrospective study included sixteen patients previously treated with OART at our institution. PSQA measurements were performed for each patient's scheduled and adaptive plans: five adaptive plans were randomly selected to perform ion chamber measurements and two adaptive plans were randomly selected for ArcCHECK measurements. The same ArcCHECK 3D dose distribution was also sent to Mobius3D to evaluate the second-check dosimetry system. RESULTS All (n = 96) ion chamber measurements agreed with the planned dose within 3% with a mean of 1.4% (± 0.7%). All (n = 48) plans passed ArcCHECK measurements using a 95% gamma passing threshold and 3%/2 mm criteria with a mean of 99.1% (± 0.7%). All (n = 48) plans passed Mobius3D second-check performed with 95% gamma passing threshold and 5%/3 mm criteria with a mean of 99.0% (± 0.2%). CONCLUSION Plan measurement for PSQA may not be necessary for every online-adaptive treatment verification. We recommend the establishment of a periodic PSQA check to better understand trends in passing rates for delivered adaptive treatments.
Collapse
Affiliation(s)
- Xiaodong Zhao
- Department of Radiation OncologyWashington University in St. LouisSt. LouisMissouriUSA
| | - Dennis N. Stanley
- Department of Radiation OncologyUniversity of Alabama at BirminghamBirminghamAlabamaUSA
| | - Carlos E. Cardenas
- Department of Radiation OncologyUniversity of Alabama at BirminghamBirminghamAlabamaUSA
| | - Joseph Harms
- Department of Radiation OncologyUniversity of Alabama at BirminghamBirminghamAlabamaUSA
| | - Richard A. Popple
- Department of Radiation OncologyUniversity of Alabama at BirminghamBirminghamAlabamaUSA
| |
Collapse
|
26
|
Moran JM, Bazan JG, Dawes SL, Kujundzic K, Napolitano B, Redmond KJ, Xiao Y, Yamada Y, Burmeister J. Quality and Safety Considerations in Intensity Modulated Radiation Therapy: An ASTRO Safety White Paper Update. Pract Radiat Oncol 2022; 13:203-216. [PMID: 36710210 DOI: 10.1016/j.prro.2022.11.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 11/11/2022] [Indexed: 12/14/2022]
Abstract
PURPOSE This updated report on intensity modulated radiation therapy (IMRT) is part of a series of consensus-based white papers previously published by the American Society for Radiation Oncology (ASTRO) addressing patient safety. Since the first white papers were published, IMRT went from widespread use to now being the main delivery technique for many treatment sites. IMRT enables higher radiation doses to be delivered to more precise targets while minimizing the dose to uninvolved normal tissue. Due to the associated complexity, IMRT requires additional planning and safety checks before treatment begins and, therefore, quality and safety considerations for this technique remain important areas of focus. METHODS AND MATERIALS ASTRO convened an interdisciplinary task force to assess the original IMRT white paper and update content where appropriate. Recommendations were created using a consensus-building methodology, and task force members indicated their level of agreement based on a 5-point Likert scale, from "strongly agree" to "strongly disagree." A prespecified threshold of ≥75% of raters who select "strongly agree" or "agree" indicated consensus. CONCLUSIONS This IMRT white paper primarily focuses on quality and safety processes in planning and delivery. Building on the prior version, this consensus paper incorporates revised and new guidance documents and technology updates. IMRT requires an interdisciplinary team-based approach, staffed by appropriately trained individuals as well as significant personnel resources, specialized technology, and implementation time. A comprehensive quality assurance program must be developed, using established guidance, to ensure IMRT is performed in a safe and effective manner. Patient safety in the delivery of IMRT is everyone's responsibility, and professional organizations, regulators, vendors, and end-users must work together to ensure the highest levels of safety.
Collapse
Affiliation(s)
- Jean M Moran
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Jose G Bazan
- Department of Radiation Oncology, Ohio State University, James Cancer Hospital and Solove Research Institute, Columbus, Ohio
| | | | | | - Brian Napolitano
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - Kristin J Redmond
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Ying Xiao
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Yoshiya Yamada
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Jay Burmeister
- Department of Oncology, Wayne State University School of Medicine, Karmanos Cancer Center, Detroit, Michigan
| |
Collapse
|
27
|
Watanabe Y, Maeyama T, Mizukami S, Tachibana H, Terazaki T, Takei H, Muraishi H, Gomi T, Hayashi SI. Verification of dose distribution in high dose-rate brachytherapy for cervical cancer using a normoxic N-vinylpyrrolidone polymer gel dosimeter. JOURNAL OF RADIATION RESEARCH 2022; 63:838-848. [PMID: 36109319 PMCID: PMC9726700 DOI: 10.1093/jrr/rrac053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 07/14/2022] [Indexed: 05/10/2023]
Abstract
The polymer gel dosimeter has been proposed for use as a 3D dosimeter for complex dose distribution measurement of high dose-rate (HDR) brachytherapy. However, various shapes of catheter/applicator for sealed radioactive source transport used in clinical cases must be placed in the gel sample. The absorbed dose readout for the magnetic resonance (MR)-based polymer gel dosimeters requires calibration data for the dose-transverse relaxation rate (R2) response. In this study, we evaluated in detail the dose uncertainty and dose resolution of three calibration methods, the multi-sample and distance methods using the Ir-192 source and the linear accelerator (linac) method using 6MV X-rays. The use of Ir-192 sources increases dose uncertainty with steep dose gradients. We clarified that the uniformly irradiated gel sample improved the signal-to-noise ratio (SNR) due to the large slice thickness of MR images and could acquire an accurate calibration curve using the linac method. The curved tandem and ovoid applicator used for intracavitary irradiation of HDR brachytherapy for cervical cancer were reproduced with a glass tube to verify the dose distribution. The results of comparison with the treatment planning system (TPS) calculation by gamma analysis on the 3%/2 mm criterion were in good agreement with a gamma pass rate of 90%. In addition, the prescription dose could be evaluated accurately. We conclude that it is easy to place catheter/applicator in the polymer gel dosimeters, making them a useful tool for verifying the 3D dose distribution of HDR brachytherapy with accurate calibration methods.
Collapse
Affiliation(s)
- Yusuke Watanabe
- Corresponding author. School of Allied Health Sciences, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan. E-mail:
| | - Takuya Maeyama
- School of Science, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Shinya Mizukami
- School of Allied Health Sciences, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Hidenobu Tachibana
- Radiation Safety and Quality Assurance division, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan
| | - Tsuyoshi Terazaki
- Department of Radiology, Yokohama City Minato Red Cross Hospital, 3-12-1 Shinyamashita, Naka-ku, Yokohama, Kanagawa, 231-8682, Japan
| | - Hideyuki Takei
- Quantum Life and Medical Science Directorate, National Institute for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba, 263-8555, Japan
| | - Hiroshi Muraishi
- School of Allied Health Sciences, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Tsutomu Gomi
- School of Allied Health Sciences, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Shin-ichiro Hayashi
- Faculty of Health Sciences, Hiroshima International University, 555-36 Kurosegakuendai, Higashihiroshima, Hiroshima, 739-2695, Japan
| |
Collapse
|
28
|
Xu Y, Zhang K, Liu Z, Liang B, Ma X, Ren W, Men K, Dai J. Treatment plan prescreening for patient-specific quality assurance measurements using independent Monte Carlo dose calculations. Front Oncol 2022; 12:1051110. [PMID: 36419878 PMCID: PMC9676489 DOI: 10.3389/fonc.2022.1051110] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Accepted: 10/19/2022] [Indexed: 11/22/2023] Open
Abstract
PURPOSE This study proposes a method to identify plans that failed patient-specific quality assurance (QA) and attempts to establish a criterion to prescreen treatment plans for patient-specific QA measurements with independent Monte Carlo dose calculations. MATERIALS AND METHODS Patient-specific QA results measured with an ArcCHECK diode array of 207 patients (head and neck: 25; thorax: 61; abdomen: 121) were retrospectively analyzed. All patients were treated with the volumetric modulated arc therapy (VMAT) technique and plans were optimized with a Pinnacle v16.2 treatment planning system using an analytical algorithm-based dose engine. Afterwards, phantom verification plans were designed and recalculated by an independent GPU-accelerated Monte Carlo (MC) dose engine, ArcherQA. Moreover, sensitivity and specificity analyzes of gamma passing rates between measurements and MC calculations were carried out to show the ability of MC to monitor failing plans (ArcCHECK 3%/3 mm,<90%), and attempt to determine the appropriate threshold and gamma passing rate criterion utilized by ArcherQA to prescreen treatment plans for ArcCHECK measurements. The receiver operator characteristic (ROC) curve was also utilized to characterize the performance of different gamma passing rate criterion used by ArcherQA. RESULTS The thresholds for 100% sensitivity to detect plans that failed patient-specific QA by independent calculation were 97.0%, 95.4%, and 91.0% for criterion 3%/3 mm, 3%/2 mm, and 2%/2 mm, respectively, which corresponded to specificities of 0.720, 0.528, and 0.585, respectively. It was shown that the 3%/3 mm criterion with 97% threshold for ArcherQA demonstrated perfect sensitivity and the highest specificity compared with other criteria, which may be suitable for prescreening treatment plans treated with the investigated machine to implement measurement-based patient-specific QA of patient plans. In addition, the area under the curve (AUC) calculated from ROC analysis for criterion 3%/3 mm, 3%/2 mm, and 2%/2 mm used by ArcherQA were 0.948, 0.924, and 0.929, respectively. CONCLUSIONS Independent dose calculation with the MC-based program ArcherQA has potential as a prescreen treatment for measurement-based patient-specific QA. AUC values (>0.9) showed excellent classification accuracy for monitoring failing plans with independent MC calculations.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Kuo Men
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jianrong Dai
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
29
|
Fabrication of 3D printed head phantom using plaster mixed with polylactic acid powder for patient-specific QA in intensity-modulated radiotherapy. Sci Rep 2022; 12:17500. [PMID: 36261615 PMCID: PMC9581964 DOI: 10.1038/s41598-022-22520-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 10/17/2022] [Indexed: 01/12/2023] Open
Abstract
This study aimed to fabricate a heterogeneous phantom replicating the commercial Rando phantom by mixing plaster powder and polylactic acid (PLA) powder. Producing a heterogeneous phantom using Plaster and PLA is cheaper because it can be easily obtained in the commercial market. Additionally, patient-specific Quality Assurance can be easily performed because the phantom can be produced based on the patient's CT image. PLA has been well studied in the field of radiation therapy and was found to be safe and effective. To match the mean Hounsfield unit (HU) values of the Rando phantom, the bone tissue was changed using plaster and 0-35% PLA powder until an appropriate HU value was obtained, and soft tissue was changed using the PLA infill value until an appropriate HU value was obtained. Bone tissue (200 HU or higher), soft issue (- 500 to 200 HU), and air cavity (less than - 500 HU) were modeled based on the HU values on the computed tomography (CT) image. The bone tissue was modeled as a cavity, and after three-dimensional (3D) printing, a solution containing a mixture of plaster and PLA powder was poured. To evaluate the bone implementation of the phantom obtained by the mixture of plaster and PLA powder, the HU profile of the CT images of the 3D-printed phantom using only PLA and the Rando phantom printed using only PLA was evaluated. The mean HU value for soft tissue in the Rando phantom (- 22.5 HU) showed the greatest similarity to the result obtained with an infill value of 82% (- 20 HU). The mean HU value for bone tissue (669 HU) showed the greatest similarity to the value obtained with 15% PLA powder (680 HU). Thus, for the phantom composed of plaster mixed with PLA powder, soft tissue was fabricated using a 3D printer with an infill value of 82%, and bone tissue was fabricated with a mixture containing 15% PLA powder. In the HU profile, this phantom showed a mean difference of 61 HU for soft tissue and 109 HU for bone tissue in comparison with the Rando phantom. The ratio of PLA powder and plaster can be adjusted to achieve an HU value similar to bone tissue. A simple combination of PLA powder and plaster enabled the creation of a custom phantom that showed similarities to the Rando phantom in both soft tissue and bone tissue.
Collapse
|
30
|
Lim SB, Kuo L, Li T, Li X, Ballangrud AM, Lovelock M, Chan MF. Comparative study of SRS end-to-end QA processes of a diode array device and an anthropomorphic phantom loaded with GafChromic XD film. J Appl Clin Med Phys 2022; 23:e13747. [PMID: 35946865 PMCID: PMC9512337 DOI: 10.1002/acm2.13747] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 03/14/2022] [Accepted: 07/19/2022] [Indexed: 11/07/2022] Open
Abstract
PURPOSE End-to-end testing (E2E) is a necessary process for assessing the readiness of the stereotactic radiosurgery (SRS) program and annual QA of an SRS system according to the AAPM MPPG 9a. This study investigates the differences between using a new SRS MapCHECK (SRSMC) system and an anthropomorphic phantom film-based system in a large network with different SRS delivery techniques. METHODS AND MATERIALS Three SRS capable Linacs (Varian Medical Systems, Palo Alto, CA) at three different regional sites were chosen to represent a hospital network, a Trilogy with an M120 multi-leaf collimator (MLC), a TrueBeam with an M120 MLC, and a TrueBeam Stx with an HD120 MLC. An anthropomorphic STEEV phantom (CIRS, Norfolk, VA) and a phantom/diode array: StereoPHAN/SRSMC (Sun Nuclear, Melbourne, FL) were CT scanned at each site. The new STV-PHANTOM EBT-XD films (Ashland, Bridgewater, NJ) were used. Six plans with various complexities were measured with both films and SRSMC in the StereoPHAN to establish their dosimetric correlations. Three SRS cranial plans with a total of sixteen fields using dynamic conformal arc and volumetric-modulated arc therapy, with 1-4 targets, were planned with Eclipse v15.5 treatment planning system (TPS) using a custom SRS beam model for each machine. The dosimetric and localization accuracy were compared. The time of analysis for the two systems by three teams of physicists was also compared to assess the throughput efficiency. RESULTS The correlations between films and SRSMC were found to be 0.84 (p = 0.03) and 0.16 (p = 0.76) for γ (3%, 1 mm) and γ (3%, 2 mm), respectively. With film, the local dose differences (ΔD) relative to the average dose within the 50% isodose line from the three sites were found to be -3.2%-3.7%. The maximum localization errors (Elocal ) were found to be within 0.5 ± 0.2 mm. With SRSMC, the ΔD was found to be within 5% of the TPS calculation. Elocal were found to be within 0.7 to 1.1 ± 0.4 mm for TrueBeam and Trilogy, respectively. Comparing with film, an additional uncertainty of 0.7 mm was found with SRSMC. The delivery and analysis times were found to be 6 and 2 h for film and SRSMC, respectively. CONCLUSIONS The SRS MapCHECK agrees dosimetrically with the films within measurement uncertainties. However, film dosimetry shows superior sub-millimeter localization resolving power for the MPPG 9a implementation.
Collapse
Affiliation(s)
- Seng Boh Lim
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - LiCheng Kuo
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Tianfang Li
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Xiang Li
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Ase M Ballangrud
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Michael Lovelock
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Maria F Chan
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| |
Collapse
|
31
|
Geurts MW, Jacqmin DJ, Jones LE, Kry SF, Mihailidis DN, Ohrt JD, Ritter T, Smilowitz JB, Wingreen NE. AAPM MEDICAL PHYSICS PRACTICE GUIDELINE 5.b: Commissioning and QA of treatment planning dose calculations-Megavoltage photon and electron beams. J Appl Clin Med Phys 2022; 23:e13641. [PMID: 35950259 PMCID: PMC9512346 DOI: 10.1002/acm2.13641] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 04/04/2022] [Accepted: 04/06/2022] [Indexed: 11/23/2022] Open
Abstract
The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines:
Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. While must is the term to be used in the guidelines, if an entity that adopts the guideline has shall as the preferred term, the AAPM considers that must and shall have the same meaning. Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances.
Collapse
|
32
|
Development and dosimetric evaluation of the IMRT prostate at outside-the-irradiated field in a heterogeneity male pelvis phantom. JOURNAL OF RADIOTHERAPY IN PRACTICE 2022. [DOI: 10.1017/s146039692200019x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
Background:
Intensity-modulated radiation therapy (IMRT) treatment delivery requires pre-treatment patient-specific quality assurance (QA) for the dosimetry verification due to its complex multileaf-collimator movement. The prostate target close position between the bladder and rectum requires a tight margin during planning, and mistreatment would have a huge impact on the patient. A commercially available QA tool consists of a homogeneous medium and does not represent an exact photon interaction on the tumour and also on the nearby healthy organ.
Objective:
A heterogeneous male pelvis phantom was developed and investigated the efficiency of the treatment planning system (TPS) calculation on the off-axis region.
Methods:
Polymethyl methacrylate was used for the phantom housing, and the material closed to the bladder, rectum and prostate density was chosen to construct the organ models. The phantom was scanned and validated by the computed tomography number and density. An IMRT treatment was planned in the Monaco TPS, and a thermoluminescent dosimeter (TLD-100) was used to validate the point dosimetry. In addition, an EGSnrc Monte Carlo simulation was carried out to validate the phantom dosimetry.
Results & Discussion:
The dose measurement between TLD-100, TPS, and EGSnrc was compared and validated in the pelvis phantom. In the prostate region, the dose difference was within ± 5%, and the maximum dose difference outside-the-irradiated field was up to 20·07 % and 47·31 % in TPS and TLD-100, respectively. Meanwhile, the measured dose was lower than the calculated dose, and it was apparent for the dose outside-the-irradiated field.
Conclusion:
The developed heterogeneity male pelvis phantom was validated and verified to be an important QA device for validating radiation dosimetry in the pelvis region. The dose outside-the-irradiated field was underestimated by both TPS and TLD, respectively.
Collapse
|
33
|
Isodoses-a set theory-based patient-specific QA measure to compare planned and delivered isodose distributions in photon radiotherapy. Strahlenther Onkol 2022; 198:849-861. [PMID: 35732919 DOI: 10.1007/s00066-022-01964-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 04/20/2022] [Indexed: 11/15/2022]
Abstract
BACKGROUND The gamma index and dose-volume histogram (DVH)-based patient-specific quality assurance (QA) measures commonly applied in radiotherapy planning are unable to simultaneously deliver detailed locations and magnitudes of discrepancy between isodoses of planned and delivered dose distributions. By exploiting statistical classification performance measures such as sensitivity or specificity, compliance between a planned and delivered isodose may be evaluated locally, both for organs-at-risk (OAR) and the planning target volume (PTV), at any specified isodose level. Thus, a patient-specific QA tool may be developed to supplement those presently available in clinical radiotherapy. MATERIALS AND METHODS A method was developed to locally establish and report dose delivery errors in three-dimensional (3D) isodoses of planned (reference) and delivered (evaluated) dose distributions simultaneously as a function the dose level and of spatial location. At any given isodose level, the total volume of delivered dose containing the reference and the evaluated isodoses is locally decomposed into four subregions: true positive-subregions within both reference and evaluated isodoses, true negative-outside of both of these isodoses, false positive-inside the evaluated isodose but not the reference isodose, and false negatives-inside the reference isodose but not the evaluated isodose. Such subregions may be established over the whole volume of delivered dose. This decomposition allows the construction of a confusion matrix and calculation of various indices to quantify the discrepancies between the selected planned and delivered isodose distributions, over the complete range of values of dose delivered. The 3D projection and visualization of the spatial distribution of these discrepancies facilitates the application of the developed method in clinical practice. RESULTS Several clinical photon radiotherapy plans were analyzed using the developed method. In some plans at certain isodose levels, dose delivery errors were found at anatomically significant locations. These errors were not otherwise highlighted-neither by gamma analysis nor by DVH-based QA measures. A specially developed 3D projection tool to visualize the spatial distribution of such errors against anatomical features of the patient aids in the proposed analysis of therapy plans. CONCLUSIONS The proposed method is able to spatially locate delivery errors at selected isodose levels and may supplement the presently applied gamma analysis and DVH-based QA measures in patient-specific radiotherapy planning.
Collapse
|
34
|
Parlar S, Uzal C. The effect of ion chamber volume on intensity-modulated radiotherapy small field dosimetry. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2022. [DOI: 10.1016/j.jrras.2022.01.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
35
|
Das IJ, Dawes SL, Dominello MM, Kavanagh B, Miyamoto CT, Pawlicki T, Santanam L, Vinogradskiy Y, Yeung AR. Quality and Safety Considerations in Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy: An ASTRO Safety White Paper Update. Pract Radiat Oncol 2022; 12:e253-e268. [DOI: 10.1016/j.prro.2022.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 03/01/2022] [Indexed: 11/17/2022]
|
36
|
Sun JC, Hsieh BT, Hsieh CM, Tsang YW, Cheng KY. Applying the N-isopropylacrylamide gel dosimeter to quantify dynamic dose effects: A feasibility study. Technol Health Care 2022; 30:413-424. [PMID: 35124616 PMCID: PMC9028750 DOI: 10.3233/thc-thc228038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND: The gel dosimeter is a chemical as well as a relative dosimeter. OBJECTIVE: To evaluate the feasibility of using N-isopropylacrylamide (NIPAM) gel dosimeter to observe the dynamic dose effects and quantification of the respiration, and to help determine the safety margins. METHODS: The NIPAM gel dosimeter combined with the dynamic phantom was used to simulate radiotherapy of lung or upper abdominal tumor. The field set to 4 × 5 cm2, simulate respiratory rate of 4 sec/cycle, and motion range 2 cm. MRI was used for reading, and MATLAB was used for analysis. The 3%/3 mm gamma passing rate > 95% was used as a clinical basis for evaluation. RESULTS: The dynamic dose curve was compared with 4 × 5, 4 × 4, 4 × 3 cm2 TPS, and gamma passing rates were 74.32%, 54.83%, 30.18%. Gamma mapping demonstrated that the highest dose region was similar to the result of the 4 × 4 cm2 TPS. After appropriate selection and comparing that the ⩾ 60% part of the dose curve with TPS, the gamma passing rate was 96.49%. CONCLUSIONS: Using the NIPAM gel dosimeter with dynamic phantom to simulate organ motion during respiration for dynamic dose measurement and quantified the dynamic dose effect is feasible. The results are consistent with clinical evaluation standards.
Collapse
Affiliation(s)
- Jung-Chang Sun
- Department of Radiation Oncology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| | - Bor-Tsung Hsieh
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| | - Chih-Ming Hsieh
- Department of Medical Imaging, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
| | - Yuk-Wah Tsang
- Department of Radiation Oncology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
- Department of Biomedical Engineering, Chung Yuan Christian University, Taoyuan, Taiwan
| | - Kai-Yuan Cheng
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| |
Collapse
|
37
|
Sun JC, Hsieh BT, Cheng CW, Hsieh CM, Tsang YW, Cheng KY. Using NIPAM gel dosimeter and concentric swing machine to simulate the dose distribution during breathing: A feasibility study. Technol Health Care 2022; 30:123-133. [PMID: 35124590 PMCID: PMC9028686 DOI: 10.3233/thc-228012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: Radiotherapy plays an important role in cancer treatment today. Successful radiotherapy includes precise positioning and accurate dosimetry. OBJECTIVE: To use NIPAM gel dosimeter and concentric swing machine to simulate and evaluate the feasibility of lung or upper abdominal tumor dose distribution during breathing. METHODS: We used a concentric swing machine to simulate actual radiotherapy for lung or upper abdomen tumors. A 4 × 4 cm2 irradiation field area was set and MRI was performed. Next, readout analysis was performed using MATLAB and the 3 mm, 3% gamma passing rate > 95% was used as a basis for evaluation. RESULTS: The concentric dynamic dose curve for a simulated respiratory rate of 3 seconds/breath and 4 × 4 cm2 field was compared with 4 × 4, 3 × 3, and 2 × 2 cm2 treatment planning systems (TPS), and the 3 mm, 3% gamma passing rate was 42.87%, 54.96%, and 49.92%, respectively. Pre-simulation showed that the high-dose region dose curve was similar to the 2 × 2 cm2 TPS result. After appropriate selection and comparison, we found that the 3 mm, 3% gamma passing rate was 97.92% on comparing the > 60% dose curve with the 2 × 2 cm2 TPS. CONCLUSIONS: NIPAM gel dosimeter and concentric swing machine use is feasible to simulate dose distribution during breathing and results conforming to clinical evaluation standards.
Collapse
Affiliation(s)
- Jung-Chang Sun
- Department of Radiation Oncology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| | - Bor-Tsung Hsieh
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| | - Chih-Wu Cheng
- Department of Radiation Oncology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
| | - Chih-Ming Hsieh
- Department of Medical Imaging, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
| | - Yuk-Wah Tsang
- Department of Radiation Oncology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
- Department of Biomedical Engineering, Chung Yuan Christian University, Taoyuan, Taiwan
| | - Kai-Yuan Cheng
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| |
Collapse
|
38
|
Dunn L, Godwin G, Hellyer J, Xu X. A method for time‐independent film dosimetry: Can we obtain accurate patient‐specific QA results at any time postirradiation? J Appl Clin Med Phys 2022; 23:e13534. [PMID: 35049118 PMCID: PMC8906213 DOI: 10.1002/acm2.13534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 12/15/2021] [Accepted: 12/30/2021] [Indexed: 11/09/2022] Open
Affiliation(s)
- Leon Dunn
- St Vincent's GenesisCare Centre for radiation oncology St Vincent's Hospital Basement Level Building C, 41 Victoria Parade, Fitzroy VIC 3065 Melbourne Victoria 3065 Australia
| | - Guy Godwin
- Redland Icon Cancer Care Bayside Business Park, 16/24 Weippin St, Cleveland QLD Brisbane Queensland 4163 Australia
| | - James Hellyer
- Macquarie University GenesisCare Centre for radiation oncology Hospital Building Suite 1, Level B2, 3 Technology Pl, Macquarie University NSW Sydney New South Wales 2109 Australia
| | - Xiaolei Xu
- St Vincent's GenesisCare Centre for radiation oncology St Vincent's Hospital Basement Level Building C, 41 Victoria Parade, Fitzroy VIC 3065 Melbourne Victoria 3065 Australia
| |
Collapse
|
39
|
Impact of stringent tolerance criteria on verification of absorbed dose distributions and evaluation through inhomogeneous media. NUCLEAR TECHNOLOGY AND RADIATION PROTECTION 2022. [DOI: 10.2298/ntrp2202138o] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Advances of radiation delivery devices have increased the complexity of the
radiation oncology treatments. Herewith, outcome of the treatment, as well
as patient safety, strongly depend on the consistency of absorbed dose
delivery. Both can be ensured by comprehensive system of verification of
calculated absorbed dose distributions. Standard method is evaluation of
calculated absorbed dose distribution according to gamma method, using a 2-D
detector and a homogeneous phantom, to obtain measured dose distribution.
Purpose of this research was to investigate the influence of tolerance
criteria on gamma passing rate. Additionally, the agreement in heterogeneous
phantom was analysed. Absorbed dose calculations were performed using systems Monaco and XiO. Detector with 1020 ionization chambers in homogeneous
phantom and semi-anthropomorphic phantom was used for measurements. Absorbed
dose distributions of around 3500 patients were analysed using gamma method.
In homogeneous phantom, average gamma passing rates were within tolerance
for 3 %/2 mm. For measurements in heterogeneous media, the highest average
gamma passing rate was obtained for small volumes of medium treatment
complexity (??=93.84%), while large volumes of treatment with low
complexity yielded the lowest gamma passing rates (??= 83.22%).
Collapse
|
40
|
Swanson W, Samba RN, Lavelle M, Elzawawy A, Sajo E, Ngwa W, Incrocci L. Practical Guidelines on Implementing Hypofractionated Radiotherapy for Prostate Cancer in Africa. Front Oncol 2021; 11:725103. [PMID: 34926247 PMCID: PMC8673781 DOI: 10.3389/fonc.2021.725103] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 11/15/2021] [Indexed: 11/13/2022] Open
Abstract
Among a growing body of literature in global oncology, several articles project increased cost savings and radiotherapy access by adopting hypofractionated radiotherapy (HFRT) in low- and middle-income countries (LMICs) like those in Africa. Clinical trials in Europe and the USA have demonstrated HFRT to be non-inferior to conventional radiotherapy for eligible patients with several cancers, including prostate cancer. This could be a highly recommended option to battle a severely large and growing cancer burden in resource-limited regions. However, a level of implementation research may be needed in limited resource-settings like in Africa. In this article, we present a list of evidence-based recommendations to practice HFRT on eligible prostate cancer patients. As literature on HFRT is still developing, these guidelines were compiled from review of several clinical trials and professionally accredited material with minimal resource requirements in mind. HFRT guidelines presented here include patient eligibility, prescription dose schedules, treatment planning and delivery techniques, and quality assurance procedures. The article provides recommendations for both moderately hypofractionated (2.4-3.4Gy per fraction) and ultrahypofractionated (5Gy or more per fraction) radiation therapy when administered by 3D-Conformal Radiotherapy, Intensity Modulated Radiation Therapy, or Image-Guided Radiotherapy. In each case radiation oncology health professionals must make the ultimate judgment to ensure safety as more LMIC centers adopt HFRT to combat the growing scourge of cancer.
Collapse
Affiliation(s)
- William Swanson
- Department of Physics and Applied Physics, University of Massachusetts Lowell, Lowell, MA, United States.,Department of Radiation Oncology, Dana Farber Cancer Institute, Brigham and Women's Hospital, and Harvard Medical School, Boston, MA, United States
| | - Richard Ndi Samba
- Department of Regulation and Regulatory Control, Cameroon National Radiation Protection Agency, Yaounde, Cameroon
| | - Michael Lavelle
- Department of Physics and Applied Physics, University of Massachusetts Lowell, Lowell, MA, United States
| | - Ahmed Elzawawy
- Department of Clinical Oncology, Suez Canal University, Ismailia, Egypt
| | - Erno Sajo
- Department of Physics and Applied Physics, University of Massachusetts Lowell, Lowell, MA, United States
| | - Wilfred Ngwa
- Department of Radiation Oncology, Dana Farber Cancer Institute, Brigham and Women's Hospital, and Harvard Medical School, Boston, MA, United States.,Department of Radiation and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, United States
| | - Luca Incrocci
- Department of Radiotherapy, Erasmus Medical Center (MC), Rotterdam, Netherlands
| |
Collapse
|
41
|
Kumar L, Bhushan M, Kishore V, Yadav G, Gurjar OP. Dosimetric validation of Acuros® XB algorithm for RapidArc™ treatment technique: A post software upgrade analysis. J Cancer Res Ther 2021; 17:1491-1498. [PMID: 34916383 DOI: 10.4103/jcrt.jcrt_1154_19] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Aim To validate the Acuros® XB (AXB) algorithm in Eclipse treatment planning system (TPS) for RapidArc™ (RA) technique following the software upgrades. Materials and Methods A Clinac-iX (2300CD) linear accelerator and Eclipse TPS (Varian Medical System, Inc., Palo Alto, USA) was used for commissioning of AXB algorithm using a 6 megavolts photon beam. Percentage depth dose (PDD) and profiles for field size 2 cm × 2 cm, 4 cm × 4 cm, 6 cm × 6 cm, 10 cm × 10 cm, 20 cm × 20 cm, 30 cm × 30 cm to 40 cm × 40 cm were taken. AXB calculated PDDs and profiles were evaluated against the measured and analytical anisotropic algorithm (AAA)-calculated PDDs and profiles. Test sites recommended by American Association of Physicists in Medicine task group (AAPM TG)-119 recommendation were used for RA planning and delivery verification using AXB algorithm. Results Dosimetric analysis of AXB calculated data showed that difference between calculated and measured data for PDD curves were maximum <1% beyond the depth of dose maximum and computed profiles in central region matches with maximum <1% for all considered field sizes. Ion-chamber measurements showed that the average confidence limit (CLs) was 0.034 and 0.020 in high-gradient and 0.047 and 0.042 in low-gradient regions, respectively, for AAA and AXB calculated RA plans. Portal measurements show the average CLs were 2.48 and 2.58 for AAA and AXB-calculated RA plans, with gamma passing criteria of 3%/3 mm. Conclusions AXB shows excellent agreement with measurements and AAA calculated data. The CLs were consistent with the baseline values published by TG-119. AXB algorithm has the potential to perform photon dose calculation with comparable fast calculation speed without negotiating the accuracy. AAPM TG-119 was successfully implemented to access the proper configuration of AXB algorithm following the TPS upgrade.
Collapse
Affiliation(s)
- Lalit Kumar
- Department of Applied Science and Humanities, Dr. A.P.J Abdul Kalam Technical University, Lucknow, Uttar Pradesh; Department of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India
| | - Manindra Bhushan
- Department of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India
| | - Vimal Kishore
- Department of Applied Science and Humanities, Bundelkhand Institute of Engineering and Technology, Jhansi, Uttar Pradesh, India
| | - Girigesh Yadav
- Department of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India
| | - Om Prakash Gurjar
- Department of Radiotherapy, Mahatma Gandhi Memorial Medical College, Indore, Madhya Pradesh, India
| |
Collapse
|
42
|
Zhang J, Li X, Lu M, Zhang Q, Zhang X, Yang R, Chan MF, Wen J. A method for in vivo treatment verification of IMRT and VMAT based on electronic portal imaging device. Radiat Oncol 2021; 16:232. [PMID: 34863229 PMCID: PMC8642849 DOI: 10.1186/s13014-021-01953-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 11/13/2021] [Indexed: 11/25/2022] Open
Abstract
Background Intensity-modulated radiation therapy (IMRT) and volume-modulated arc therapy (VMAT) are rather complex treatment techniques and require patient-specific quality assurance procedures. Electronic portal imaging devices (EPID) are increasingly used in the verification of radiation therapy (RT). This work aims to develop a novel model to predict the EPID transmission image (TI) with fluence maps from the RT plan. The predicted TI is compared with the measured TI for in vivo treatment verification. Methods The fluence map was extracted from the RT plan and corrections of penumbra, response, global field output, attenuation, and scatter were applied before the TI was calculated. The parameters used in the model were calculated separately for central axis and off-axis points using a series of EPID measurement data. Our model was evaluated using a CIRS thorax phantom and 20 clinical plans (10 IMRT and 10 VMAT) optimized for head and neck, breast, and rectum treatments. Results Comparisons of the predicted and measured images were carried out using a global gamma analysis of 3%/2 mm (10% threshold) to validate the accuracy of the model. The gamma pass rates for IMRT and VMAT were greater than 97.2% and 94.5% at 3%/2 mm, respectively. Conclusion We have developed an accurate and straightforward EPID-based quality assurance model that can potentially be used for in vivo treatment verification of the IMRT and VMAT delivery.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing, China.
| | - Xiuqing Li
- Department of Engineering Physics, Tsinghua University, Beijing, China
| | - Miaomiao Lu
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Qilin Zhang
- Department of Radiation Oncology, Peking University Third Hospital, Beijing, China
| | - Xile Zhang
- Department of Radiation Oncology, Peking University Third Hospital, Beijing, China
| | - Ruijie Yang
- Department of Radiation Oncology, Peking University Third Hospital, Beijing, China
| | - Maria F Chan
- Medical Physics Department, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Junhai Wen
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing, China.
| |
Collapse
|
43
|
Finneman GM, Eichhorn OH, Meskell NR, Caplice TW, Benson AD, Abu-Halawa AS, Ademoski GL, Clark AC, Gayer DS, Hendrickson KN, Debbins PA, Onel Y, Ayan AS, Akgun U. Development of a dosimeter prototype with machine learning based 3-D dose reconstruction capabilities. Biomed Phys Eng Express 2021; 8. [PMID: 34768242 DOI: 10.1088/2057-1976/ac396c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 11/12/2021] [Indexed: 11/12/2022]
Abstract
A 3-D dosimeter fills the need for treatment plan and delivery verification required by every modern radiation-therapy method used today. This report summarizes a proof-of-concept study to develop a water-equivalent solid 3-D dosimeter that is based on novel radiation-hard scintillating material. The active material of the prototype dosimeter is a blend of radiation-hard peroxide-cured polysiloxane plastic doped with scintillating agent P-Terphenyl and wavelength-shifter BisMSB. The prototype detector was tested with 6 MV and 10 MV x-ray beams at Ohio State University's Comprehensive Cancer Center. A 3-D dose distribution was successfully reconstructed by a neural network specifically trained for this prototype. This report summarizes the material production procedure, the material's water equivalency investigation, the design of the prototype dosimeter and its beam tests, as well as the details of the utilized machine learning approach and the reconstructed 3-D dose distributions.
Collapse
Affiliation(s)
- G M Finneman
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| | - O H Eichhorn
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| | - N R Meskell
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| | - T W Caplice
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| | - A D Benson
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| | - A S Abu-Halawa
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| | - G L Ademoski
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| | - A C Clark
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| | - D S Gayer
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| | - K N Hendrickson
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| | - P A Debbins
- Department of Physics and Astronomy, University of Iowa, Iowa City, IA, United States of America
| | - Y Onel
- Department of Physics and Astronomy, University of Iowa, Iowa City, IA, United States of America
| | - A S Ayan
- Comprehensive Cancer Center, Ohio State University, Columbus, OH, United States of America
| | - U Akgun
- Physics Department, Coe College, Cedar Rapids, IA, United States of America
| |
Collapse
|
44
|
Development of an x-ray-opaque-marker system for quantitative phantom positioning in patient-specific quality assurance. Phys Med 2021; 91:121-130. [PMID: 34785490 DOI: 10.1016/j.ejmp.2021.10.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 10/10/2021] [Accepted: 10/30/2021] [Indexed: 11/21/2022] Open
Abstract
PURPOSE We developed an x-ray-opaque-marker (XOM) system with inserted fiducial markers for patient-specific quality assurance (QA) in CyberKnife (Accuray) and a general-purpose linear accelerator (linac). The XOM system can be easily inserted or removed from the existing patient-specific QA phantom. Our study aimed to assess the utility of the XOM system by evaluating the recognition accuracy of the phantom position error and estimating the dose perturbation around a marker. METHODS The recognition accuracy of the phantom position error was evaluated by comparing the known error values of the phantom position with the values measured by matching the images with target locating system (TLS; Accuray) and on-board imager (OBI; Varian). The dose perturbation was evaluated for 6 and 10 MV single-photon beams through experimental measurements and Monte Carlo simulations. RESULTS The root mean squares (RMSs) of the residual position errors for the recognition accuracy evaluation in translations were 0.07 mm with TLS and 0.30 mm with OBI, and those in rotations were 0.13° with TLS and 0.15° with OBI. The dose perturbation was observed within 1.5 mm for 6 MV and 2.0 mm for 10 MV from the marker. CONCLUSIONS Sufficient recognition accuracy of the phantom position error was achieved using our system. It is unnecessary to consider the dose perturbation in actual patient-specific QA. We concluded that the XOM system can be utilized to ensure quantitative and accurate phantom positioning in patient-specific QA with CyberKnife and a general-purpose linac.
Collapse
|
45
|
Kouris P, Moutsatsos A, Pappas EP, Beli I, Pantelakos P, Karaiskos P, Pantelis E. Assessing the dose rate delivery of helical TomoTherapy prostate and head & neck treatments. Biomed Phys Eng Express 2021; 8. [PMID: 34755680 DOI: 10.1088/2057-1976/ac37cb] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 11/09/2021] [Indexed: 11/11/2022]
Abstract
The dose rate distributions delivered to 55 prostate and head & neck (H&N) cancer patients treated with a helical TomoTherapy (HT) system were resolved and assessed with regard to pitch and field width defined during treatment planning. Statistical analysis of the studied cases showed that the median treatment delivery time was 4.4 min and 6.3 min for the prostate and H&N cases, respectively. Dose rate volume histogram data for the studied cases showed that the 25% and 12% of the volume of the planning target volumes of the prostate and H&N cases are irradiated with a dose rate of greater or equal to 1 Gy min-1. Quartile dose rate (QDR) data confirmed that in HT, where the target is irradiated in slices, most of the dose is delivered to each voxel of the target when it travels within the beam. Analysis of the planning data from all cases showed that this lasts for 68 s (median value). QDRs results showed that using the 2.5 cm field width, 75% of the prescribed dose is delivered to target voxels with a median dose rate of at least 3.2 Gy min-1and 4.5 Gy min-1, for the prostate and H&N cases, respectively. Systematically higher dose rates were observed for the H&N cases due to the shallower depths of the lesions in this anatomical site. Delivered dose rates were also found to increase with field width and pitch setting, due to the higher output of the system which, in general, results in accordingly decreased total treatment time. The biological effect of the dose rate findings of this work needs to be further investigated using in-vitro studies and clinical treatment data.
Collapse
Affiliation(s)
- P Kouris
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 75 Mikras Asias, 11527 Athens, Greece
| | - A Moutsatsos
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 75 Mikras Asias, 11527 Athens, Greece.,Radiotherapy and Radiosurgery Department, Latropolis Clinic, 54-56 Ethnikis Antistaseos, 15231 Athens, Greece
| | - E P Pappas
- Radiotherapy and Radiosurgery Department, Latropolis Clinic, 54-56 Ethnikis Antistaseos, 15231 Athens, Greece
| | - I Beli
- Radiotherapy and Radiosurgery Department, Latropolis Clinic, 54-56 Ethnikis Antistaseos, 15231 Athens, Greece
| | - P Pantelakos
- Radiotherapy and Radiosurgery Department, Latropolis Clinic, 54-56 Ethnikis Antistaseos, 15231 Athens, Greece
| | - P Karaiskos
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 75 Mikras Asias, 11527 Athens, Greece
| | - E Pantelis
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 75 Mikras Asias, 11527 Athens, Greece.,Radiotherapy and Radiosurgery Department, Latropolis Clinic, 54-56 Ethnikis Antistaseos, 15231 Athens, Greece
| |
Collapse
|
46
|
Gray A, Bawazeer O, Arumugam S, Vial P, Descallar J, Thwaites D, Holloway L. Evaluation of the ability of three commercially available dosimeters to detect systematic delivery errors in step-and-shoot IMRT plans. Rep Pract Oncol Radiother 2021; 26:793-803. [PMID: 34760314 DOI: 10.5603/rpor.a2021.0093] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Accepted: 07/03/2021] [Indexed: 11/25/2022] Open
Abstract
Background There is limited data on error detectability for step-and-shoot intensity modulated radiotherapy (sIMRT) plans, despite significant work on dynamic methods. However, sIMRT treatments have an ongoing role in clinical practice. This study aimed to evaluate variations in the sensitivity of three patient-specific quality assurance (QA) devices to systematic delivery errors in sIMRT plans. Materials and methods Four clinical sIMRT plans (prostate and head and neck) were edited to introduce errors in: Multi-Leaf Collimator (MLC) position (increasing field size, leaf pairs offset (1-3 mm) in opposite directions; and field shift, all leaves offset (1-3 mm) in one direction); collimator rotation (1-3 degrees) and gantry rotation (0.5-2 degrees). The total dose for each plan was measured using an ArcCHECK diode array. Each field, excluding those with gantry offsets, was also measured using an Electronic Portal Imager and a MatriXX Evolution 2D ionisation chamber array. 132 plans (858 fields) were delivered, producing 572 measured dose distributions. Measured doses were compared to calculated doses for the no-error plan using Gamma analysis with 3%/3 mm, 3%/2 mm, and 2%/2 mm criteria (1716 analyses). Results Generally, pass rates decreased with increasing errors and/or stricter gamma criteria. Pass rate variations with detector and plan type were also observed. For a 3%/3 mm gamma criteria, none of the devices could reliably detect 1 mm MLC position errors or 1 degree collimator rotation errors. Conclusions This work has highlighted the need to adapt QA based on treatment plan type and the need for detector specific assessment criteria to detect clinically significant errors.
Collapse
Affiliation(s)
- Alison Gray
- Liverpool and Macarthur Cancer Therapy Centres, South Western Sydney Local Health District, Sydney, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, School of Medicine, University of New South Wales, Sydney, NSW, Australia
| | - Omemh Bawazeer
- Physics Department, Umm Al-Qura University, Mecca, Saudi Arabia
| | - Sankar Arumugam
- Liverpool and Macarthur Cancer Therapy Centres, South Western Sydney Local Health District, Sydney, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, School of Medicine, University of New South Wales, Sydney, NSW, Australia
| | - Philip Vial
- Liverpool and Macarthur Cancer Therapy Centres, South Western Sydney Local Health District, Sydney, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, School of Medicine, University of New South Wales, Sydney, NSW, Australia.,Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW, Australia
| | - Joseph Descallar
- Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, School of Medicine, University of New South Wales, Sydney, NSW, Australia
| | - David Thwaites
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW, Australia
| | - Lois Holloway
- Liverpool and Macarthur Cancer Therapy Centres, South Western Sydney Local Health District, Sydney, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, School of Medicine, University of New South Wales, Sydney, NSW, Australia.,Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
| |
Collapse
|
47
|
Tang LL, Chen YP, Chen CB, Chen MY, Chen NY, Chen XZ, Du XJ, Fang WF, Feng M, Gao J, Han F, He X, Hu CS, Hu DS, Hu GY, Jiang H, Jiang W, Jin F, Lang JY, Li JG, Lin SJ, Liu X, Liu QF, Ma L, Mai HQ, Qin JY, Shen LF, Sun Y, Wang PG, Wang RS, Wang RZ, Wang XS, Wang Y, Wu H, Xia YF, Xiao SW, Yang KY, Yi JL, Zhu XD, Ma J. The Chinese Society of Clinical Oncology (CSCO) clinical guidelines for the diagnosis and treatment of nasopharyngeal carcinoma. Cancer Commun (Lond) 2021; 41:1195-1227. [PMID: 34699681 PMCID: PMC8626602 DOI: 10.1002/cac2.12218] [Citation(s) in RCA: 140] [Impact Index Per Article: 46.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 08/24/2021] [Accepted: 09/08/2021] [Indexed: 02/05/2023] Open
Abstract
Nasopharyngeal carcinoma (NPC) is a malignant epithelial tumor originating in the nasopharynx and has a high incidence in Southeast Asia and North Africa. To develop these comprehensive guidelines for the diagnosis and management of NPC, the Chinese Society of Clinical Oncology (CSCO) arranged a multi‐disciplinary team comprising of experts from all sub‐specialties of NPC to write, discuss, and revise the guidelines. Based on the findings of evidence‐based medicine in China and abroad, domestic experts have iteratively developed these guidelines to provide proper management of NPC. Overall, the guidelines describe the screening, clinical and pathological diagnosis, staging and risk assessment, therapies, and follow‐up of NPC, which aim to improve the management of NPC.
Collapse
Affiliation(s)
- Ling-Long Tang
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, Guangdong, 510060, P. R. China
| | - Yu-Pei Chen
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, Guangdong, 510060, P. R. China
| | - Chuan-Ben Chen
- Department of Radiation Oncology, Fujian Provincial Cancer Hospital, Fujian Medical University Department of Radiation Oncology, Teaching Hospital of Fujian Medical University Provincial Clinical College, Cancer Hospital of Fujian Medical University, Fuzhou, Fujian, 350014, P. R. China
| | - Ming-Yuan Chen
- Department of Nasopharyngeal Carcinoma, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong, 510060, P. R. China
| | - Nian-Yong Chen
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, P. R. China
| | - Xiao-Zhong Chen
- Cancer Hospital of the University of Chinese Academy of Sciences (Zhejiang Cancer Hospital), Institute of Cancer and Basic Medicine (IBMC), Chinese Academy of Sciences, Hangzhou, Zhejiang, 310000, P. R. China
| | - Xiao-Jing Du
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, Guangdong, 510060, P. R. China
| | - Wen-Feng Fang
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Medical Oncology Department, Sun Yat-Sen University Cancer Center, Guangzhou, Guangdong, 510060, P. R. China
| | - Mei Feng
- Department of Radiation Oncology, Sichuan Cancer Hospital and Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan, 610041, P. R. China
| | - Jin Gao
- Department of Radiation Oncology, Anhui Provincial Hospital Affiliated to Anhui Medical University, Hefei, Anhui, 230001, P. R. China
| | - Fei Han
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, Guangdong, 510060, P. R. China
| | - Xia He
- Department of Clinical Laboratory, Affiliated Cancer Hospital of Nanjing Medical University, Jiangsu Cancer Hospital, Jiangsu Institute of Cancer Research, Nanjing, Jiangsu, 210000, P. R. China
| | - Chao-Su Hu
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, P. R. China
| | - De-Sheng Hu
- Department of Radiotherapy, Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430079, P. R. China
| | - Guang-Yuan Hu
- Department of Oncology, Tongji Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan, Hubei, 430030, P. R. China
| | - Hao Jiang
- Department of Radiation Oncology, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, 233004, P. R. China
| | - Wei Jiang
- Department of Radiation Oncology, Affiliated Hospital of Guilin Medical University, Guilin, Guangxi, 541001, P. R. China
| | - Feng Jin
- Key Laboratory of Basic Pharmacology and Joint International Research Laboratory of Ethnomedicine of Ministry of Education, Zunyi Medical University, No. 6, Xuefu West Road, Xinpu New District, Zunyi, Guizhou, 563000, P. R. China
| | - Jin-Yi Lang
- Department of Radiation Oncology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan, 610041, P. R. China
| | - Jin-Gao Li
- Department of Radiotherapy, Jiangxi Cancer Hospital, Nanchang, Jiangxi, 330029, P. R. China
| | - Shao-Jun Lin
- Department of Radiation Oncology, Fujian Provincial Cancer Hospital, Fujian Medical University Department of Radiation Oncology, Teaching Hospital of Fujian Medical University Provincial Clinical College, Cancer Hospital of Fujian Medical University, Fuzhou, Fujian, 350014, P. R. China
| | - Xu Liu
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, Guangdong, 510060, P. R. China
| | - Qiu-Fang Liu
- Department of Radiotherapy, Shaanxi Provincial Cancer Hospital Affiliated to Medical College, Xi'an Jiaotong University, Xi'an, Shaanxi, 710000, P. R. China
| | - Lin Ma
- Department of Radiation Oncology, First Medical Center of Chinese PLA General Hospital, Beijing, 100000, P. R. China
| | - Hai-Qiang Mai
- Department of Nasopharyngeal Carcinoma, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong, 510060, P. R. China
| | - Ji-Yong Qin
- Department of Radiation Oncology, Yunnan Cancer Hospital, The Third Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, 650100, P. R. China
| | - Liang-Fang Shen
- Department of Radiation Oncology, Xiangya Hospital of Central South University, 87 Xiangya Road, Changsha, Hunan, 410008, P. R. China
| | - Ying Sun
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, Guangdong, 510060, P. R. China
| | - Pei-Guo Wang
- Department of Radiotherapy, National Clinical Research Center for Cancer, Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, P. R. China
| | - Ren-Sheng Wang
- Department of Radiation Oncology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, 530000, P. R. China
| | - Ruo-Zheng Wang
- Department of Radiation Oncology, Key Laboratory of Oncology in Xinjiang Uyghur Autonomous Region, The Affiliated Tumor Hospital of Xinjiang Medical University, Urumqi, Xinjiang, 830000, P. R. China
| | - Xiao-Shen Wang
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, P. R. China
| | - Ying Wang
- Department of Radiation Oncology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, 400000, P. R. China
| | - Hui Wu
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Zhengzhou, Henan, 450000, P. R. China
| | - Yun-Fei Xia
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, Guangdong, 510060, P. R. China
| | - Shao-Wen Xiao
- Department of Radiotherapy, Peking University School of Oncology, Beijing Cancer Hospital and Institute, Beijing, Haidian District, 100142, P. R. China
| | - Kun-Yu Yang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, P. R. China
| | - Jun-Lin Yi
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, P. R. China
| | - Xiao-Dong Zhu
- Department of Radiotherapy, Guangxi Medical University Cancer Hospital, Nanning, Guangxi, 530000, P. R. China
| | - Jun Ma
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, Guangdong, 510060, P. R. China
| |
Collapse
|
48
|
Development of an Electronic Portal Imaging Device Dosimetry Method. Diagnostics (Basel) 2021; 11:diagnostics11091654. [PMID: 34573994 PMCID: PMC8464714 DOI: 10.3390/diagnostics11091654] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/31/2021] [Accepted: 09/06/2021] [Indexed: 12/03/2022] Open
Abstract
Support arm backscatter and off-axis effects of an electronic portal imaging device (EPID) are challenging for radiotherapy quality assurance. Aiming at the issue, we proposed a simple yet effective method with correction matrices to rectify backscatter and off-axis responses for EPID images. First, we measured the square fields with ionization chamber array (ICA) and EPID simultaneously. Second, we calculated the dose-to-pixel value ratio and used it as the correction matrix of the corresponding field. Third, the correction value of the large field was replaced with that of the same point in the small field to generate a correction matrix suitable for different EPID images. Finally, we rectified the EPID image with the correction matrix, and then the processed EPID images were converted into the absolute dose. The calculated dose was compared with the measured dose via ICA. The gamma pass rates of 3%/3 mm and 2%/2 mm (5% threshold) were 99.6% ± 0.94% and 95.48% ± 1.03%, and the average gamma values were 0.28 ± 0.04 and 0.42 ± 0.05, respectively. Experimental results verified our method accurately corrected EPID images and converted pixel values into absolute dose values such that EPID was an efficient radiotherapy dosimetry tool.
Collapse
|
49
|
Tsuneda M, Nishio T, Ezura T, Karasawa K. Plastic scintillation dosimeter with a conical mirror for measuring 3D dose distribution. Med Phys 2021; 48:5639-5650. [PMID: 34389992 DOI: 10.1002/mp.15164] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 03/22/2021] [Accepted: 08/01/2021] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To test the measurement technique of the three-dimensional (3D) dose distribution measured image by capturing the scintillation light generated using a plastic scintillator and a scintillating screen. METHODS Our imaging system constituted a column shaped plastic scintillator covered by a Gd2 O2 S:Tb scintillating screen, a conical mirror and a cooled CCD camera. The scintillator was irradiated with 6 MV photon beams. Meanwhile, the irradiated plan was prepared for the static field plans, two-field plan (2F plan) and the conformal arc plan (CA plan). The 2F plan contained 16 mm2 and 10 mm2 fields irradiated from gantry angles of 0° and 25°, respectively. The gantry was rotated counterclockwise from 45° to 315° for the CA plan. The field size was then obtained as 10 mm2 . A Monte Carlo simulation was performed in the experimental geometry to obtain the calculated 3D dose distribution as the reference data. Dose response was acquired by comparing between the reference and the measurement. The dose rate dependence was verified by irradiating the same MU value at different dose rates ranging from 100 to 600 MU/min. Deconvolution processing was applied to the measured images for the correction of light blurring. The measured 3D dose distribution was reconstructed from each measured image. Gamma analysis was performed to these 3D dose distributions. The gamma criteria were 3% for the dose difference, 2 mm for the distance-to-agreement and 10% for the threshold. RESULTS Dose response for the scintillation light was linear. The variation in the light intensity for the dose rate ranging from 100 to 600 MU/min was less than 0.5%, while our system presents dose rate independence. For the 3D dose measurement, blurring of light through deconvolution processing worked well. The 3D gamma passing rate (3D GPR) for the 10 × 10 mm2 , 16 × 16 mm2 , and 20 × 20 mm2 fields were observed to be 99.3%, 98.8%, and 97.8%, respectively. Reproducibility of measurement was verified. The 3D GPR results for the 2F plan and the CA plan were 99.7% and 100%, respectively. CONCLUSIONS We developed a plastic scintillation dosimeter and demonstrated that our system concept can act as a suitable technique for measuring the 3D dose distribution from the gamma results. In the future, we will attempt to measure the 4D dose distribution for clinical volumetric modulated arc radiation therapy (VMAT)-SBRTplans.
Collapse
Affiliation(s)
- Masato Tsuneda
- Department of Radiation Oncology, Tokyo Women's Medical University, Shinjuku-ku, Tokyo, Japan
| | - Teiji Nishio
- Department of Medical Physics, Tokyo Women's Medical University, Shinjuku-ku, Tokyo, Japan
| | - Takatomo Ezura
- Division of Radiation Medical Physics, Kanagawa Cancer Center, Yokohama, Kanagawa, Japan
| | - Kumiko Karasawa
- Department of Radiation Oncology, Tokyo Women's Medical University, Shinjuku-ku, Tokyo, Japan
| |
Collapse
|
50
|
Osman AFI, Maalej NM. Applications of machine and deep learning to patient-specific IMRT/VMAT quality assurance. J Appl Clin Med Phys 2021; 22:20-36. [PMID: 34343412 PMCID: PMC8425899 DOI: 10.1002/acm2.13375] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/20/2021] [Accepted: 07/18/2021] [Indexed: 01/10/2023] Open
Abstract
In order to deliver accurate and safe treatment to cancer patients in radiation therapy using advanced techniques such as intensity modulated radiation therapy (IMRT) and volumetric-arc radiation therapy (VMAT), patient specific quality assurance (QA) should be performed before treatment. IMRT/VMAT dose measurements in a phantom using various devices have been clinically adopted as standard method for QA. This approach allows the verification of the accuracy of the dose calculation, data transfer, and the delivery system. However, patient-specific QA procedures are expensive and require significant time and effort by the physicists. Over the past 5 years, machine learning (ML) and deep learning (DL) algorithms for predictions of IMRT/VMAT QA outcome have been investigated. Various ML and DL models have shown promising prediction accuracy and a high potential as time-efficient virtual QA tool. In this paper, we review the ML and DL based models that were developed for patient specific IMRT and VMAT QA outcome predictions from algorithmic and clinical applicability perspectives. We focus on comparing the algorithms, the dataset sizes, the input parameters and features, the QA outcome prediction approaches, the validation, the performance, the clinical applicability, and the potential clinical impact. In addition, we discuss the present challenges as well as the future directions in the implementation of these models. To the best of our knowledge, this is the first review on the application of ML and DL based models in IMRT/VMAT QA predictions.
Collapse
Affiliation(s)
| | - Nabil M Maalej
- Department of Physics, Khalifa University, Abu Dhabi, UAE
| |
Collapse
|