1
|
Conroy C, Kidd G. Informational masking in the modulation domain. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:3665. [PMID: 34241144 PMCID: PMC8163511 DOI: 10.1121/10.0005038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Uncertainty regarding the frequency spectrum of a masker can have an adverse effect on the ability to focus selective attention on a target frequency channel, yielding informational masking (IM). This study sought to determine if uncertainty regarding the modulation spectrum of a masker can have an analogous adverse effect on the ability to focus selective attention on a target modulation channel, yielding IM in the modulation domain, or "modulation IM." A single-interval, two-alternative forced-choice (yes-no) procedure was used. The task was to detect 32-Hz target sinusoidal amplitude modulation (SAM) imposed on a broadband-noise carrier in the presence of masker SAM imposed on the same carrier. Six maskers, spanning the range from 8 to 128 Hz in half-octave steps, were tested, excluding those that fell within a two-octave protected zone surrounding the target. Psychometric functions (d'-vs-target modulation depth) were measured for each masker under two conditions: a fixed (low-uncertainty/low-IM) condition, in which the masker was the same on all trials within a block, and a random (high-uncertainty/high-IM) condition, in which it varied randomly from presentation-to-presentation. Thresholds and slopes extracted from the psychometric functions differed markedly between the conditions. These results are consistent with the idea that IM occurs in the modulation domain.
Collapse
Affiliation(s)
- Christopher Conroy
- Department of Speech, Language & Hearing Sciences and Hearing Research Center, Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02215, USA
| | - Gerald Kidd
- Department of Speech, Language & Hearing Sciences and Hearing Research Center, Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02215, USA
| |
Collapse
|
2
|
Conroy C, Mason CR, Kidd G. Informational masking of negative masking. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:798. [PMID: 32113297 PMCID: PMC7004829 DOI: 10.1121/10.0000652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 01/10/2020] [Accepted: 01/10/2020] [Indexed: 06/10/2023]
Abstract
Negative masking (NM) is a ubiquitous finding in near-"threshold" psychophysics in which the detectability of a near-threshold signal improves when added to a copy of itself, i.e., a pedestal or masker. One interpretation of NM suggests that the pedestal acts as an informative cue, thereby reducing uncertainty and improving performance relative to detection in its absence. The purpose of this study was to test this hypothesis. Intensity discrimination thresholds were measured for 100-ms, 1000-Hz near-threshold tones. In the reference condition, thresholds were measured in quiet (no masker other than the pedestal). In comparison conditions, thresholds were measured in the presence of one of two additional maskers: a notched-noise masker or a random-frequency multitone masker. The additional maskers were intended to cause different amounts of uncertainty and, in turn, to differentially influence NM. The results were generally consistent with an uncertainty-based interpretation of NM: NM was found both in quiet and in notched-noise, yet it was eliminated by the multitone masker. A competing interpretation of NM based on nonlinear transduction does not account for all of the results. Profile analysis may have been a factor in performance and this suggests that NM may be attributable to, or influenced by, multiple mechanisms.
Collapse
Affiliation(s)
- Christopher Conroy
- Department of Speech, Language & Hearing Sciences and Hearing Research Center, Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02215, USA
| | - Christine R Mason
- Department of Speech, Language & Hearing Sciences and Hearing Research Center, Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02215, USA
| | - Gerald Kidd
- Department of Speech, Language & Hearing Sciences and Hearing Research Center, Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02215, USA
| |
Collapse
|
3
|
Bonino AY, Leibold LJ. Adults, but not children, benefit from a pretrial signal cue in a random-frequency, two-tone masker. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 138:EL8-EL13. [PMID: 26233066 PMCID: PMC4499049 DOI: 10.1121/1.4922365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2015] [Revised: 05/06/2015] [Accepted: 05/27/2015] [Indexed: 06/04/2023]
Abstract
This study examined the benefit of a pretrial cue, a preview of the signal, on children's (5-10 years) and adults' detection of a 1000-Hz pure-tone signal in a broadband noise or a random-frequency, two-tone masker. No cuing effect was observed with the noise masker, regardless of listener age. In contrast, all but one adult benefited from the cue with the two-tone masker (average = 9.4 dB). Most children showed no cuing effect (average = 0.1 dB) with the two-tone masker. These results suggest that, unlike adults, the provision of a pretrial cue does not promote frequency-selective listening during detection for 5- to 10-year-olds.
Collapse
Affiliation(s)
- Angela Yarnell Bonino
- Department of Allied Health Sciences, University of North Carolina School of Medicine, CB 7190, Chapel Hill, North Carolina 27599, USA ,
| | - Lori J Leibold
- Department of Allied Health Sciences, University of North Carolina School of Medicine, CB 7190, Chapel Hill, North Carolina 27599, USA ,
| |
Collapse
|
4
|
Leibold LJ. Development of Auditory Scene Analysis and Auditory Attention. HUMAN AUDITORY DEVELOPMENT 2012. [DOI: 10.1007/978-1-4614-1421-6_5] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
5
|
Dai H, Micheyl C. Psychophysical reverse correlation with multiple response alternatives. J Exp Psychol Hum Percept Perform 2010; 36:976-93. [PMID: 20695712 PMCID: PMC3158580 DOI: 10.1037/a0017171] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Psychophysical reverse-correlation methods such as the "classification image" technique provide a unique tool to uncover the internal representations and decision strategies of individual participants in perceptual tasks. Over the past 30 years, these techniques have gained increasing popularity among both visual and auditory psychophysicists. However, thus far, principled applications of the psychophysical reverse-correlation approach have been almost exclusively limited to two-alternative decision (detection or discrimination) tasks. Whether and how reverse-correlation methods can be applied to uncover perceptual templates and decision strategies in situations involving more than just two response alternatives remain largely unclear. Here, the authors consider the problem of estimating perceptual templates and decision strategies in stimulus identification tasks with multiple response alternatives. They describe a modified correlational approach, which can be used to solve this problem. The approach is evaluated under a variety of simulated conditions, including different ratios of internal-to-external noise, different degrees of correlations between the sensory observations, and various statistical distributions of stimulus perturbations. The results indicate that the proposed approach is reasonably robust, suggesting that it could be used in future empirical studies.
Collapse
Affiliation(s)
- Huanping Dai
- Department of Speech, Language, and Hearing Sciences, University of Arizona, Tucson, AZ 85721, USA.
| | | |
Collapse
|
6
|
Leibold LJ, Hitchens JJ, Buss E, Neff DL. Excitation-based and informational masking of a tonal signal in a four-tone masker. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2010; 127:2441-50. [PMID: 20370027 PMCID: PMC2865701 DOI: 10.1121/1.3298588] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2009] [Revised: 12/31/2009] [Accepted: 01/05/2010] [Indexed: 05/29/2023]
Abstract
This study examined contributions of peripheral excitation and informational masking to the variability in masking effectiveness observed across samples of multi-tonal maskers. Detection thresholds were measured for a 1000-Hz signal presented simultaneously with each of 25, four-tone masker samples. Using a two-interval, forced-choice adaptive task, thresholds were measured with each sample fixed throughout trial blocks for ten listeners. Average thresholds differed by as much as 26 dB across samples. An excitation-based model of partial loudness [Moore, B. C. J. et al. (1997). J. Audio Eng. Soc. 45, 224-237] was used to predict thresholds. These predictions accounted for a significant portion of variance in the data of several listeners, but no relation between the model and data was observed for many listeners. Moreover, substantial individual differences, on the order of 41 dB, were observed for some maskers. The largest individual differences were found for maskers predicted to produce minimal excitation-based masking. In subsequent conditions, one of five maskers was randomly presented in each interval. The difference in performance for samples with low versus high predicted thresholds was reduced in random compared to fixed conditions. These findings are consistent with a trading relation whereby informational masking is largest for conditions in which excitation-based masking is smallest.
Collapse
Affiliation(s)
- Lori J Leibold
- Department of Allied Health Sciences, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
| | | | | | | |
Collapse
|
7
|
Marrone N, Mason CR, Kidd G. Tuning in the spatial dimension: evidence from a masked speech identification task. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 124:1146-58. [PMID: 18681603 PMCID: PMC2809679 DOI: 10.1121/1.2945710] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2007] [Revised: 05/23/2008] [Accepted: 05/28/2008] [Indexed: 05/23/2023]
Abstract
Spatial release from masking was studied in a three-talker soundfield listening experiment. The target talker was presented at 0 degrees azimuth and the maskers were either colocated or symmetrically positioned around the target, with a different masker talker on each side. The symmetric placement greatly reduced any "better ear" listening advantage. When the maskers were separated from the target by +/-15 degrees , the average spatial release from masking was 8 dB. Wider separations increased the release to more than 12 dB. This large effect was eliminated when binaural cues and perceived spatial separation were degraded by covering one ear with an earplug and earmuff. Increasing reverberation in the room increased the target-to-masker ratio (TM) for the separated, but not colocated, conditions reducing the release from masking, although a significant advantage of spatial separation remained. Time reversing the masker speech improved performance in both the colocated and spatially separated cases but lowered TM the most for the colocated condition, also resulting in a reduction in the spatial release from masking. Overall, the spatial tuning observed appears to depend on the presence of interaural differences that improve the perceptual segregation of sources and facilitate the focus of attention at a point in space.
Collapse
Affiliation(s)
- Nicole Marrone
- Department of Speech, Language, and Hearing Sciences and the Hearing Research Center, Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02215, USA.
| | | | | |
Collapse
|
8
|
Hall JW, Buss E, Grose JH. Comodulation detection differences in children and adults. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 123:2213-9. [PMID: 18397027 PMCID: PMC2633723 DOI: 10.1121/1.2839006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2007] [Revised: 11/14/2007] [Accepted: 01/08/2008] [Indexed: 05/25/2023]
Abstract
This study investigated comodulation detection differences (CDD) in children (ages 4.8-10.1 years) and adults. The signal was 30-Hz wide band of noise centered on 2 kHz, and the masker consisted of six 30-Hz wide bands of noise spanning center frequencies from 870 to 4160 Hz. The envelopes of the masking bands were always comodulated, and the envelope of the signal was either comodulated or random with respect to the masker. In some conditions, the maskers were gated on prior to the signal in order to minimize effects related to perceptual fusion of the signal and masker. CDD was computed as the difference between signal detection thresholds in conditions where all bands were comodulated and conditions where the envelope of the signal was random with respect to the envelopes of the maskers. Values of CDD were generally small in children compared to adults. In contrast, masking release related to masker/signal onset asynchrony was comparable across age groups. The small CDDs in children are discussed in terms of sensitivity to comodulation as a perceptual fusion cue and informational masking associated with the detection of a signal in a complex background, an effect that is ameliorated by asynchronous onset.
Collapse
Affiliation(s)
- Joseph W Hall
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, North Carolina 27599, USA.
| | | | | |
Collapse
|
9
|
|
10
|
Hall JW, Buss E, Grose JH. Comodulation detection differences for fixed-frequency and roved-frequency maskers. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2006; 119:1021-8. [PMID: 16521764 PMCID: PMC2646379 DOI: 10.1121/1.2151788] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
This study investigated comodulation detection differences (CDD) for fixed- and roved-frequency maskers. The objective was to determine whether CDD could be accounted for better in terms of energetic masking or in terms of perceptual fusion/segregation related to comodulation. Roved-frequency maskers were used in order to minimize the role of energetic masking, allowing possible effects related to perceptual fusion/segregation to be revealed. The signals and maskers were composed of 30-Hz-wide noise bands. The signal was either comodulated with the masker (A/A condition) or had a temporal envelope that was independent (A/B condition). The masker was either gated synchronously with the signal or had a leading temporal fringe of 200 ms. In the fixed-frequency masker conditions, listeners with low A/A thresholds showed little masking release due to masker temporal fringe and had CDDs that could be accounted for by energetic masking. Listeners with higher A/A thresholds in the fixed-frequency masker conditions showed relatively large CDDs and large masking release due to a masker temporal fringe. The CDDs of these listeners may have arisen, at least in part, from processes related to perceptual segregation. Some listeners in the roved masker conditions also had large CDDs that appeared to be related to perceptual segregation.
Collapse
Affiliation(s)
- Joseph W Hall
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, North Carolina 27599, USA.
| | | | | |
Collapse
|
11
|
Wightman FL, Kistler DJ. Informational masking of speech in children: effects of ipsilateral and contralateral distracters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2005; 118:3164-76. [PMID: 16334898 PMCID: PMC2819474 DOI: 10.1121/1.2082567] [Citation(s) in RCA: 130] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Using a closed-set speech recognition paradigm thought to be heavily influenced by informational masking, auditory selective attention was measured in 38 children (ages 4-16 years) and 8 adults (ages 20-30 years). The task required attention to a monaural target speech message that was presented with a time-synchronized distracter message in the same ear. In some conditions a second distracter message or a speech-shaped noise was presented to the other ear. Compared to adults, children required higher target/distracter ratios to reach comparable performance levels, reflecting more informational masking in these listeners. Informational masking in most conditions was confirmed by the fact that a large proportion of the errors made by the listeners were contained in the distracter message(s). There was a monotonic age effect, such that even the children in the oldest age group (13.6-16 years) demonstrated poorer performance than adults. For both children and adults, presentation of an additional distracter in the contralateral ear significantly reduced performance, even when the distracter messages were produced by a talker of different sex than the target talker. The results are consistent with earlier reports from pure-tone masking studies that informational masking effects are much larger in children than in adults.
Collapse
Affiliation(s)
- Frederic L Wightman
- Heuser Hearing Institute, Department of Psychological and Brain Sciences, University of Louisville, Louisville, Kentucky 40292, USA.
| | | |
Collapse
|
12
|
Durlach NI, Mason CR, Gallun FJ, Shinn-Cunningham B, Colburn HS, Kidd G. Informational masking for simultaneous nonspeech stimuli: psychometric functions for fixed and randomly mixed maskers. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2005; 118:2482-97. [PMID: 16266169 DOI: 10.1121/1.2032748] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Sensitivity d' and response bias beta were measured as a function of target level for the detection of a 1000-Hz tone in multitone maskers using a one interval, two-alternative forced-choice (1I-2AFC) paradigm. Ten such maskers, each with eight randomly selected components in the region 200-5000 Hz, with 800-1250 Hz excluded to form a protected zone, were presented under two conditions: the fixed condition, in which the same eight-component masker is used throughout an experimental run, and the random condition, in which an eight-component masker is chosen randomly trial-to-trial from the given set of ten such maskers. Differences between the results obtained with these two conditions help characterize the listener's susceptibility to informational masking (IM). The d' results show great intersubject variability, but can be reasonably well fit by simple energy-detector models in which internal noise and filter bandwidth are used as fitting parameters. In contrast, the beta results are not well fit by these models. In addition to presentation of new data and its relation to energy-detector models, this paper provides comments on a variety of issues, problems, and research needs in the IM area.
Collapse
Affiliation(s)
- Nathaniel I Durlach
- Hearing Research Center Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02215, USA.
| | | | | | | | | | | |
Collapse
|
13
|
Hall JW, Buss E, Grose JH. Informational masking release in children and adults. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2005; 118:1605-13. [PMID: 16247871 PMCID: PMC1810353 DOI: 10.1121/1.1992675] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
This study assessed informational masking and utilization of cues to reduce that masking in children aged 4-9 years and in adults. The signal was a train of eight consecutive tone bursts, each at 1 kHz and 60 ms in duration. Maskers were comprised of a pair of synchronous tone-burst trains, with randomly chosen frequencies spanning 200-5000 Hz, with a protected region 851-1175 Hz. In the reference condition, maskers were eight bursts in duration, with a fixed frequency within intervals. Experiment 1 tested two monotic masking release conditions: within-interval randomization of masker burst frequency and the introduction of leading masker bursts. Experiment 2 examined masking release in which the signal was presented to one ear and masking components were presented to both ears (masker components in the contralateral ear were 10 dB higher than those in the ipsilateral ear). Both adults and children demonstrated a significant informational masking effect, with children showing a larger effect on average. Both groups also showed significant release from masking in the two monotic conditions, although children received somewhat less benefit from the masking release cues. The binaural condition supported a moderate release from informational masking in adults, but resulted in increased informational masking in children.
Collapse
Affiliation(s)
- Joseph W Hall
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, North Carolina 27599, USA.
| | | | | |
Collapse
|
14
|
Kidd G, Mason CR, Gallun FJ. Combining energetic and informational masking for speech identification. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2005; 118:982-92. [PMID: 16158654 DOI: 10.1121/1.1953167] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
This study examined combinations of energetic and informational maskers in speech identification. Speech targets and maskers (speech or noise) were processed and filtered into sets of 15 narrow frequency bands. The target was the sum of eight randomly selected bands. More masking occurred for speech maskers than for spectrally matched noise maskers regardless of whether the masker bands overlapped the target bands. The greater effect of the speech maskers was interpreted as due to informational masking. When the masker was comprised of nonoverlapping bands of speech, the addition of bands of noise overlapping the speech masker, but not the speech target, reduced the overall amount of masking. Surprisingly, presenting the noise to the ear contralateral to the target and masker produced an even greater release from masking. The contralateral noise was apparently sufficient to cause a slight change in the image of the ipsilateral speech masker, possibly pulling it away from the target enough to allow the focus of attention on the target. This finding is consistent with the interpretation that in some conditions small binaural differences may be sufficient to cause, or significantly strengthen, the perceptual segregation of sounds.
Collapse
Affiliation(s)
- Gerald Kidd
- Department of Speech, Language and Hearing Sciences and Hearing Research Center, Sargent College, Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02215, USA.
| | | | | |
Collapse
|
15
|
Lutfi RA, Alexander JM. Effects of informational maskers within and across trials. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2005; 118:322-4. [PMID: 16119352 DOI: 10.1121/1.1923348] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The across-trial effect of maskers in conditions of informational masking was evaluated from performance on occasional trials in which the signal was presented alone. For 6 of 12 listeners participating in the study, a significant number of errors were obtained on signal-alone trials; in some cases equivalent to that signal+ masker trials. On immediately preceding trial blocks for which there were no intervening maskers, performance for these signals was perfect. The results indicate that informational maskers can have a significant effect on signal threshold, both within and across trials.
Collapse
Affiliation(s)
- Robert A Lutfi
- Department of Communicative Disorders, and Waisman Center, University of Wisconsin, Madison, Wisconsin 53705, USA.
| | | |
Collapse
|
16
|
Dye RH, Stellmack MA, Jurcin NF. Observer weighting strategies in interaural time-difference discrimination and monaural level discrimination for a multi-tone complex. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2005; 117:3079-90. [PMID: 15957776 DOI: 10.1121/1.1861832] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Two experiments measured listeners' abilities to weight information from different components in a complex of 553, 753, and 953 Hz. The goal was to determine whether or not the ability to adjust perceptual weights generalized across tasks. Weights were measured by binary logistic regression between stimulus values that were sampled from Gaussian distributions and listeners' responses. The first task was interaural time discrimination in which listeners judged the laterality of the target component. The second task was monaural level discrimination in which listeners indicated whether the level of the target component decreased or increased across two intervals. For both experiments, each of the three components served as the target. Ten listeners participated in both experiments. The results showed that those individuals who adjusted perceptual weights in the interaural time experiment could also do so in the monaural level discrimination task. The fact that the same individuals appeared to be analytic in both tasks is an indication that the weights measure the ability to attend to a particular region of the spectrum while ignoring other spectral regions.
Collapse
Affiliation(s)
- Raymond H Dye
- Parmly Hearing Institute, Loyola University of Chicago, Chicago, Illinois 60626, USA
| | | | | |
Collapse
|
17
|
Grose JH, Hall JW, Buss E. Across-channel spectral processing. INTERNATIONAL REVIEW OF NEUROBIOLOGY 2005; 70:87-119. [PMID: 16472632 DOI: 10.1016/s0074-7742(05)70003-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- John H Grose
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | | | | |
Collapse
|
18
|
Neff DL, Odgaard EC. Sample discrimination of frequency differences with distracters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2004; 116:3051-3061. [PMID: 15603150 DOI: 10.1121/1.1802571] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
This study examined the effect of the type and frequency range of remote frequency distracters on sample discrimination of frequency differences (SD-F). For baseline SD-F conditions, normal-hearing listeners judged frequency differences between pairs of target tones drawn from Gaussian frequency distributions near 2000 Hz. In experiment 1, the distracters were pairs of random-frequency tones, fixed-frequency tones, or noise bands, with one distracter above and one below the target region. Three frequency separations of targets and distracters were tested, none overlapping the target region. Effects of fixed-frequency or noise-band distracters were small compared to that of random-frequency distracters, which drove performance to near chance. In experiment 2, dominance of the low-frequency distracter was supported by the effects of changing distracter level, by presenting only the higher- or lower-frequency distracter, and by the pattern of weights derived from trial-by-trial responses. Performance recovered only when the lower-frequency distracter was attenuated 40-50 dB relative to the targets. In experiment 3, all stimulus distributions were shifted 2 octaves higher in frequency; the stronger influence of the distracter frequency below the target remained. The results demonstrate the importance of both stimulus variability and frequency relationships in the interaction of targets and distracters for SD-F.
Collapse
Affiliation(s)
- Donna L Neff
- Boys Town National Research Hospital, Omaha, Nebraska 68131, USA.
| | | |
Collapse
|
19
|
Joliveau E, Smith J, Wolfe J. Vocal tract resonances in singing: the soprano voice. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2004; 116:2234-47. [PMID: 15532674 DOI: 10.1121/1.1784437] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The vocal tract resonances of trained soprano singers were measured while they sang a range of vowels softly at different pitches. The measurements were made by broad band acoustic excitation at the mouth, which allowed the resonances of the tract to be measured simultaneously with and independently from the harmonics of the voice. At low pitch, when the lowest resonance frequency R1 exceeded f0, the values of the first two resonances R1 and R2 varied little with frequency and had values consistent with normal speech. At higher pitches, however, when fo exceeded the value of R1 observed at low pitch, R1 increased with f0 so that R1 was approximately equal to f0. R2 also increased over this high pitch range, probably as an incidental consequence of the tuning of R1. R3 increased slightly but systematically, across the whole pitch range measured. There was no evidence that any resonances are tuned close to harmonics of the pitch frequency except for R1 at high pitch. The variations in R1 and R2 at high pitch mean that vowels move, converge, and overlap their positions on the vocal plane (R2,R1) to an extent that implies loss of intelligibility.
Collapse
Affiliation(s)
- Elodie Joliveau
- School of Physics, University of New South Wales, Sydney NSW 2052, Australia
| | | | | |
Collapse
|
20
|
Lutfi RA, Kistler DJ, Callahan MR, Wightman FL. Psychometric functions for informational masking. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 114:3273-82. [PMID: 14714808 PMCID: PMC2858973 DOI: 10.1121/1.1629303] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
The term informational masking has traditionally been used to refer to elevations in signal threshold resulting from masker uncertainty. In the present study, the method of constant stimuli was used to obtain complete psychometric functions (PFs) from 44 normal-hearing listeners in conditions known to produce varying amounts of informational masking. The listener's task was to detect a pure-tone signal in the presence of a broadband noise masker (low masker uncertainty) and in the presence of multitone maskers with frequencies and amplitudes that varied at random from one presentation to the next (high masker uncertainty). Relative to the broadband noise condition, significant reductions were observed in both the slope and the upper asymptote of the PF for multitone maskers producing large amounts of informational masking. Slope was affected more for some listeners and conditions while asymptote was affected more for others; consequently, neither parameter alone was highly predictive of individual thresholds or the amount of informational masking. Mean slopes and asymptotes varied nonmonotonically with the number of masker components in a manner similar to mean thresholds, particularly when the estimated effect of energetic masking on thresholds was subtracted out. As in past studies, the threshold data were well described by a model in which trial-by-trial judgments are based on a weighted sum of levels in dB at the output of independent auditory filters. The psychometric data, however, complicated the model's interpretation in two ways: First, they suggested that, depending on the listener and condition, the weights can either reflect a fixed influence of masker components on each trial or the effect of occasionally mistaking a masker component for the signal from trial to trial. Second, they indicated that in either case the variance of the underlying decision variable as estimated from PF slope is not by itself great enough to account for the observed changes in informational masking.
Collapse
Affiliation(s)
- Robert A Lutfi
- Waisman Center, University of Wisconsin, Madison, Wisconsin 53705, USA
| | | | | | | |
Collapse
|
21
|
Kidd G, Mason CR, Richards VM. Multiple bursts, multiple looks, and stream coherence in the release from informational masking. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 114:2835-2845. [PMID: 14650018 DOI: 10.1121/1.1621864] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
In the simultaneous multitone masking paradigm introduced by Neff and Green [Percept. Psychophys. 41, 409-415 (1987)] the masker typically is a small number of tones having frequencies and levels that are randomly drawn on every presentation. Large amounts of masking for a pure-tone signal often occur that are thought to reflect central, rather than peripheral, limitations on processing. Previous work from this laboratory has indicated that playing a rapid succession of randomly drawn multitone maskers in each observation interval dramatically reduces the amount of masking that is observed relative to a single burst (SB). In this multiple-bursts-different (MBD) procedure, the signal tone is the only constant frequency component during the sequence of bursts and tends to perceptually segregate from the masker. In this study, the number of masker bursts and the interburst interval (IBI) were varied. The goals were to determine how the release from masking relative to the SB condition depends on the number of bursts and to examine whether increasing the IBI would cause each burst to be processed independently. If the latter were true, it might disrupt the perception of signal stream coherence, thereby diminishing the MBD advantage. However, multiple independent looks could also lead to an improvement in performance. For those subjects showing large amounts of informational masking in the SB condition, substantial reduction in masked thresholds occurred as the number of masker bursts increased, while masking increased as IBI lengthened. The results were not consistent with a simple version of a multiple-look model in which the information from each burst was combined optimally, but instead appear to be attributable to mechanisms involved in the perceptual organization of sounds.
Collapse
Affiliation(s)
- Gerald Kidd
- Hearing Research Center and Programs in Communication Disorders, Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02215, USA.
| | | | | |
Collapse
|
22
|
Kidd G, Mason CR, Brughera A, Chiu CYP. Discriminating harmonicity. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 114:967-977. [PMID: 12942976 DOI: 10.1121/1.1587734] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Simultaneous tones that are harmonically related tend to be grouped perceptually to form a unitary auditory image. A partial that is mistuned stands out from the other tones, and harmonic complexes with different fundamental frequencies can readily be perceived as separate auditory objects. These phenomena are evidence for the strong role of harmonicity in perceptual grouping and segregation of sounds. This study measured the discriminability of harmonicity directly. In a two interval, two alternative forced-choice (2I2AFC) paradigm, the listener chose which of two sounds, signal or foil, was composed of tones that more closely matched an exact harmonic relationship. In one experiment, the signal was varied from perfectly harmonic to highly inharmonic by adding frequency perturbation to each component. The foil always had 100% perturbation. Group mean performance decreased from greater than 90% correct for 0% signal perturbation to near chance for 80% signal perturbation. In the second experiment, adding a masker presented simultaneously with the signals and foils disrupted harmonicity. Both monaural and dichotic conditions were tested. Signal level was varied relative to masker level to obtain psychometric functions from which slopes and midpoints were estimated. Dichotic presentation of these audible stimuli improved performance by 3-10 dB, due primarily to a release from "informational masking" by the perceptual segregation of the signal from the masker.
Collapse
Affiliation(s)
- Gerald Kidd
- Hearing Research Center Sargent College, Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02215, USA.
| | | | | | | |
Collapse
|
23
|
Durlach NI, Mason CR, Shinn-Cunningham BG, Arbogast TL, Colburn HS, Kidd G. Informational masking: counteracting the effects of stimulus uncertainty by decreasing target-masker similarity. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 114:368-379. [PMID: 12880048 DOI: 10.1121/1.1577562] [Citation(s) in RCA: 128] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Previous work has indicated that target-masker similarity, as well as stimulus uncertainty, influences the amount of informational masking that occurs in detection, discrimination, and recognition tasks. In each of five experiments reported in this paper, the detection threshold for a tonal target in random multitone maskers presented simultaneously with the target tone was measured for two conditions using the same set of five listeners. In one condition, the target was constructed to be "similar" (S) to the masker; in the other condition, it was constructed to be "dissimilar" (D) to the masker. The specific masker varied across experiments, but was constant for the two conditions. Target-masker similarity varied in dimensions such as duration, perceived location, direction of frequency glide, and spectro-temporal coherence. Group-mean results show large decreases in the amount of masking for the D condition relative to the S condition. In addition, individual differences (a hallmark of informational masking) are found to be much greater in the S condition than in the D condition. Furthermore, listener vulnerability to informational masking is found to be consistent to at least a moderate degree across experiments.
Collapse
Affiliation(s)
- Nathaniel I Durlach
- Hearing Research Center, Boston University, Boston, Massachusetts 02215, USA.
| | | | | | | | | | | |
Collapse
|
24
|
Tang Z, Richards VM. Examination of a linear model in an informational masking study. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 114:361-367. [PMID: 12880047 DOI: 10.1121/1.1579006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
When multitone maskers are used in a two-interval, forced choice experiment, the amount of masking is larger when the masker is randomly chosen on each presentation interval compared to on each trial (the same masker in the two listening intervals). These conditions are referred to as having within- versus between-trial randomization. If it is assumed that an observer's ultimate detection decision depends on a single decision variable (DV), it is probable that the DV's variance will be substantially larger in the within-trial randomization condition compared to the between-trial randomization condition. The goal of the current experiment is to evaluate the degree to which this stimulus-based change in DV variance can account for the difference in thresholds in the within-versus between-trial randomization conditions. Thresholds are measured for the detection of a tone added to a six-component masker in between- and within-trial randomization conditions. The slopes of the psychometric functions provide an estimate of the variance in the DV for the between- and within-trial randomization conditions. Additionally, a channel model is fitted to the psychophysical results in the within-trial randomization condition. The resulting model is then used to predict the value of the DV for each trial, and ultimately to estimate the proportion of the total variance in the within-trial randomization condition that is attributable to changes in maskers across intervals. The variance of the DV in the between-trial randomization condition accounted for approximately 65% of the total variance in the DV in the within-trial randomization condition. Stimulus-based interval-by-interval masker randomization accounted for approximately 20% of the total variance of the within-trial randomization DV. The remaining 15% of the DV variance in the within-trial randomization condition remained unaccounted for. This result is fairly stable whether the maskers are drawn from a small versus large pool of potential maskers.
Collapse
Affiliation(s)
- Zhongzhou Tang
- Department of Psychology, University of Pennsylvania, 3815 Walnut Street, Philadelphia, Pennsylvania 19104, USA
| | | |
Collapse
|
25
|
Durlach NI, Mason CR, Kidd G, Arbogast TL, Colburn HS, Shinn-Cunningham BG. Note on informational masking. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 113:2984-7. [PMID: 12822768 DOI: 10.1121/1.1570435] [Citation(s) in RCA: 246] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
|
26
|
Kidd G, Mason CR, Arbogast TL, Brungart DS, Simpson BD. Informational masking caused by contralateral stimulation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 113:1594-1603. [PMID: 12656394 DOI: 10.1121/1.1547440] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Although informational masking is thought to reflect central mechanisms, the effects are generally much stronger when the target and masker are presented to the same ear than when they are presented to different ears. However, the results of a recent study by Brungart and Simpson [J. Acoust. Soc. Am. 112, 2985-2995 (2002)] indicated that a speech masker that is presented contralateral to a speech signal can produce substantial amounts of informational masking when a second speech masker is played simultaneously in the same ear as the signal. In this study, we conducted a series of experiments that paralleled those of Brungart and Simpson but used a pure-tone signal and multitone informational maskers in a detection task. Both the signal and the maskers were played as sequences of short bursts in each observation interval. The maskers were arranged in two types of spectrotemporal patterns. One type of pattern, called "multiple-bursts same" (MBS), has previously been shown to produce very large amounts of informational masking while the other type of pattern, called "multiple-bursts different" (MBD), has been shown to produce very small amounts of informational masking. Several conditions of ipsilateral, contralateral, and combined presentation of these maskers were tested. The results showed that presentation of the MBS masker in the contralateral ear produced a substantial amount of informational masking when the MBD masker was simultaneously presented to the ipsilateral ear. The results supported the earlier findings of Brungart and Simpson indicating that listeners are unable to selectively focus their attention on a single ear in some complex dichotic listening conditions. These results suggest that this contralateral masking effect is not restricted to speech and may reflect more general limitations on processing capacity. Further, it was concluded that the magnitude of the contralateral masking effect was related both to the informational masking value of the contralateral masker and the complexity of the stimulus and/or task in the ear in which the signal was presented.
Collapse
Affiliation(s)
- Gerald Kidd
- Hearing Research Center, Sargent College, Boston University, 635 Commonwealth Avenue, Boston, Massachusetts 02132, USA.
| | | | | | | | | |
Collapse
|