1
|
Kim S, Jo Y, Im GH, Lee C, Oh C, Kook G, Kim SG, Lee HJ. Miniaturized MR-compatible ultrasound system for real-time monitoring of acoustic effects in mice using high-resolution MRI. Neuroimage 2023; 276:120201. [PMID: 37269955 DOI: 10.1016/j.neuroimage.2023.120201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/24/2023] [Accepted: 05/26/2023] [Indexed: 06/05/2023] Open
Abstract
Visualization of focused ultrasound in high spatial and temporal resolution is crucial for accurately and precisely targeting brain regions noninvasively. Magnetic resonance imaging (MRI) is the most widely used noninvasive tool for whole-brain imaging. However, focused ultrasound studies employing high-resolution (> 9.4 T) MRI in small animals are limited by the small size of the radiofrequency (RF) volume coil and the noise sensitivity of the image to external systems such as bulky ultrasound transducers. This technical note reports a miniaturized ultrasound transducer system packaged directly above a mouse brain for monitoring ultrasound-induced effects using high-resolution 9.4 T MRI. Our miniaturized system integrates MR-compatible materials with electromagnetic (EM) noise reduction techniques to demonstrate echo-planar imaging (EPI) signal changes in the mouse brain at various ultrasound acoustic intensities. The proposed ultrasound-MRI system will enable extensive research in the expanding field of ultrasound therapeutics.
Collapse
Affiliation(s)
- Subeen Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea
| | - Yehhyun Jo
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea
| | - Geun Ho Im
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, South Korea
| | - Chanhee Lee
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, South Korea
| | - Chaerin Oh
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea
| | - Geon Kook
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea
| | - Seong-Gi Kim
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, South Korea; Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, South Korea; Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon 16419, South Korea.
| | - Hyunjoo J Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea; KAIST Institute for Nano Century (KINC), Daejeon 34141, South Korea.
| |
Collapse
|
2
|
Sadeghi-Goughari M, Han SW, Kwon HJ. Real-time monitoring of focused ultrasound therapy using intelligence-based thermography: A feasibility study. ULTRASONICS 2023; 134:107100. [PMID: 37421699 DOI: 10.1016/j.ultras.2023.107100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 06/28/2023] [Accepted: 07/01/2023] [Indexed: 07/10/2023]
Abstract
Focused ultrasound (FUS) therapy has been widely studied for breast cancer treatment due to its potential as a fully non-invasive method to improve cosmetic and oncologic results. However, real-time imaging and monitoring of the therapeutic ultrasound delivered to the target area remain challenges for precision breast cancer therapy. The main objective of this study is to propose and evaluate a novel intelligence-based thermography (IT) method that can monitor and control FUS treatment using thermal imaging with the fusion of artificial intelligence (AI) and advanced heat transfer modeling. In the proposed method, a thermal camera is integrated into FUS system for thermal imaging of the breast surface, and an AI model is employed for the inverse analysis of the surface thermal monitoring, thereby estimating the features of the focal region. This paper presents experimental and computational studies conducted to assess the feasibility and efficiency of IT-guided FUS (ITgFUS). Tissue phantoms, designed to mimic the properties of breast tissue, were used in the experiments to investigate detectability and the impact of temperature rise at the focal region on the tissue surface. Additionally, an AI computational analysis employing an artificial neural network (ANN) and FUS simulation was carried out to provide a quantitative estimation of the temperature rise at the focal region. This estimation was based on the observed temperature profile on the breast model's surface. The results proved that the effects of temperature rise at the focused area could be detected by the thermal images acquired with thermography. Moreover, it was demonstrated that the AI analysis of the surface temperature measurement could result in near real-time monitoring of FUS by quantitative estimation of the temporal and spatial temperature rise profiles at the focal region.
Collapse
Affiliation(s)
- Moslem Sadeghi-Goughari
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| | - Sang-Wook Han
- Department of Automotive Engineering, Shinhan University, 95 Hoam-ro, Uijeongbu, Gyeonggi-do 480-701, Republic of Korea
| | - Hyock-Ju Kwon
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
3
|
Antoniou A, Nikolaou A, Georgiou A, Evripidou N, Damianou C. Development of an US, MRI, and CT imaging compatible realistic mouse phantom for thermal ablation and focused ultrasound evaluation. ULTRASONICS 2023; 131:106955. [PMID: 36854247 DOI: 10.1016/j.ultras.2023.106955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 11/09/2022] [Accepted: 02/10/2023] [Indexed: 06/18/2023]
Abstract
Tissue mimicking phantoms (TMPs) play an essential role in modern biomedical research as cost-effective quality assurance and training tools, simultaneously contributing to the reduction of animal use. Herein, we present the development and evaluation of an anatomically accurate mouse phantom intended for image-guided thermal ablation and Focused Ultrasound (FUS) applications. The proposed mouse model consists of skeletal and soft tissue mimics, whose design was based on the Computed tomography (CT) scans data of a live mouse. Advantageously, it is compatible with US, CT, and Magnetic Resonance Imaging (MRI). The compatibility assessment was focused on the radiological behavior of the phantom due to the lack of relevant literature. The X-ray linear attenuation coefficient of candidate materials was estimated to assess the one that matches best the radiological behavior of living tissues. The bone part was manufactured by Fused Deposition Modeling (FDM) printing using Acrylonitrile styrene acrylate (ASA) material. For the soft-tissue mimic, a special mold was 3D printed having a cavity with the unique shape of the mouse body and filled with an agar-based silica-doped gel. The mouse phantom accurately matched the size and reproduced the body surface of the imaged mouse. Tissue-equivalency in terms of X-ray attenuation was demonstrated for the agar-based soft-tissue mimic. The phantom demonstrated excellent MRI visibility of the skeletal and soft-tissue mimics. Good radiological contrast between the skeletal and soft-tissue models was also observed in the CT scans. The model was also able to reproduce realistic behavior during trans-skull sonication as proved by thermocouple measurements. Overall, the proposed phantom is inexpensive, ergonomic, and realistic. It could constitute a powerful tool for image-guided thermal ablation and FUS studies in terms of testing and optimizing the performance of relevant equipment and protocols. It also possess great potential for use in transcranial FUS applications, including the emerging topic of FUS-mediated blood brain barrier (BBB) disruption.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| | - Anastasia Nikolaou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| | - Andreas Georgiou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| | - Nikolas Evripidou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| |
Collapse
|
4
|
Reza MT, Moubarak NNI, Islam MR, Khan MRH, Nishat MM. Optimization of breast cancer ablation volume by ultrasonic pressure field characterization. SENSING AND BIO-SENSING RESEARCH 2023. [DOI: 10.1016/j.sbsr.2023.100553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/17/2023] Open
|
5
|
Numerical and experimental evaluation of ultrasound-assisted convection enhanced delivery to transfer drugs into brain tumors. Sci Rep 2022; 12:19299. [PMID: 36369259 PMCID: PMC9652304 DOI: 10.1038/s41598-022-23429-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Accepted: 10/31/2022] [Indexed: 11/13/2022] Open
Abstract
Central Nervous System (CNS) malignant tumors are a leading cause of death worldwide with a high mortality rate. While numerous strategies have been proposed to treat CNS tumors, the treatment efficacy is still low mainly due to the existence of the Blood-Brain Barrier (BBB). BBB is a natural cellular layer between the circulatory system and brain extracellular fluid, limiting the transfer of drug particles and confining the routine treatment strategies in which drugs are released in the blood. Consequently, direct drug delivery methods have been devised to bypass the BBB. However, the efficiency of these methods is not enough to treat deep and large brain tumors. In the study at hand, the effect of focused ultrasound (FUS) waves on enhancing drug delivery to brain tumors, through ultrasound-assisted convection-enhanced delivery (UCED), has been investigated. First, brain mimicking gels were synthesized to mimic the CNS microenvironment, and the drug solution was injected into them. Second, FUS waves with the resonance frequency of 1.1 MHz were applied to the drug injected zone. Next, a finite element (FE) model was developed to evaluate the pre-existing equation in the literature for describing the drug delivery via acoustic streaming in brain tissue. Experimental results showed that the FUS transducer was able to enhance the drug volume distribution up to 500% relative to convection-enhanced delivery alone (CED). Numerical analysis showed that the FE model could replicate the experimental penetration depths with a mean difference value of less than 21%, and acoustic streaming plays a significant role in UCED. Therefore, the results of this study could open a new way to develop FE models of the brain to better evaluate the UCED and reduce the costs of conducting clinical and animal studies.
Collapse
|
6
|
Zhao Y, Qin D, Chen J, Hou J, Ilovitsh T, Wan M, Wu L, Feng Y. On-demand regulation and enhancement of the nucleation in acoustic droplet vaporization using dual-frequency focused ultrasound. ULTRASONICS SONOCHEMISTRY 2022; 90:106224. [PMID: 36368292 PMCID: PMC9649937 DOI: 10.1016/j.ultsonch.2022.106224] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 10/29/2022] [Accepted: 11/03/2022] [Indexed: 06/16/2023]
Abstract
Acoustic droplet vaporization (ADV) plays an important role in focused ultrasound theranostics. Better understanding of the relationship between the ultrasound parameters and the ADV nucleation could provide an on-demand regulation and enhancement of ADV for improved treatment outcome. In this work, ADV nucleation was performed in a dual-frequency focused ultrasound configuration that consisted of a continuous low-frequency ultrasound and a short high-frequency pulse. The combination was modelled to investigate the effects of the driving frequency and acoustic power on the nucleation rate, efficiency, onset time, and dimensions of the nucleation region. The results showed that the inclusion of short pulsed high-frequency ultrasound significantly increased the nucleation rate with less energy, reduced the nucleation onset time, and changed the length-width ratio of the nucleation region, indicating the dual-frequency ultrasound mode yields an efficient enhancement of the ADV nucleation, compared to a single-frequency ultrasound mode. Furthermore, the acoustic and temperature fields varied independently with the dual-frequency ultrasound parameters. This facilitated the spatial and temporal control over the ADV nucleation, and opens the door to the possibility to realize on-demand regulation of the ADV occurrence in ultrasound theranostics. In addition, the improved energy efficacy that is obtained with the dual-frequency configuration lowered the requirements on hardware system, increasing its flexibility and could facilitate its implementation in practical applications.
Collapse
Affiliation(s)
- Yubo Zhao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Dui Qin
- School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing, People's Republic of China
| | - Junjie Chen
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Jin Hou
- Department of Otorhinolaryngology Head & Neck Surgery, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Tali Ilovitsh
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Liang Wu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China.
| | - Yi Feng
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China.
| |
Collapse
|
7
|
Zhong X, Cao Y, Zhou P. Thermochromic Tissue-Mimicking Phantoms for Thermal Ablation Based on Polyacrylamide Gel. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1361-1372. [PMID: 35623921 DOI: 10.1016/j.ultrasmedbio.2022.03.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 03/29/2022] [Accepted: 03/30/2022] [Indexed: 06/15/2023]
Abstract
In recent years, thermal ablation has played an increasingly important role in treating various tumors in the clinic. A practical thermochromic phantom model can provide a favorable platform for clinical thermotherapy training of young physicians or calibration and optimization of thermal devices without risk to animals or human participants. To date, many tissue-mimicking thermal phantoms have been developed and are well liked, especially the polyacrylamide gel (PAG)-based phantoms. This review summarizes the PAG-based phantoms in the field of thermotherapy, details their advantages and disadvantages and provides a direction for further optimization. The relevant physical parameters (such as electrical, acoustic, and thermal properties) of these phantoms are also presented in this review, which can assist operators in a deeper understanding of these phantoms and selection of the proper recipes for phantom fabrication.
Collapse
Affiliation(s)
- Xinyu Zhong
- Department of Ultrasound, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Yuting Cao
- Institute of Ultrasound Imaging & Department of Ultrasound, Second Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ultrasound Molecular Imaging, Chongqing, China
| | - Ping Zhou
- Department of Ultrasound, Third Xiangya Hospital, Central South University, Changsha, Hunan, China.
| |
Collapse
|
8
|
Shamloo A, Boroumand A, Ebrahimi S, Kalantarnia F, Maleki S, Moradi H. Modeling of an Ultrasound System in Targeted Drug Delivery to Abdominal Aortic Aneurysm: A Patient-Specific in Silico Study Based on Ligand-Receptor Binding. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:967-974. [PMID: 34958631 DOI: 10.1109/tuffc.2021.3138868] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Targeted drug delivery methods have shown a significant impact on enhancing drug delivery efficiency and reducing drug side effects. While various stimuli have been used to promote the drug delivery process, applying ultrasound (US) waves to control drug particles through the human body, noninvasively, has drawn the scientist's attention. However, microcarriers delivery reaches the aneurysmal artery by US waves that exert volumetric forces on blood, and drug carriers, which can therefore affect blood flow patterns and movement pathways of drug carriers, have not yet been studied. In this study, we developed a 3-D patient-specific model of abdominal aortic aneurysm (AAA) to evaluate the effect of US waves in enhancing the drug-containing microbubbles (MBs) adhered on the AAA lumen through ligand-receptor binding. Thus, a focused US (FUS) transducer with a resonance frequency of ~1.1 MHz was added to the geometry. Then, the surface density of MBs (SDM) adhered on the AAA lumen was calculated at peak acoustic pressure of ~1.1, ~2.2, and ~4.3 MPa. Results indicated that increasing the US pressure had a significant impact on improving the MBs adhered to the intended wall, whereby US waves with the maximum pressure of ~4.3 MPa could enhance ~1- [Formula: see text] MBs adhesion ~98% relative to not using the waves. While US waves have the advantage of more SDM adhered to the whole artery wall, they adversely affect the SDM adhered on the critical wall of the abdominal aorta. Furthermore, when the US strength goes up, a reduction occurs in the SDM adhered. This reduction is higher for smaller MBs, which is the mentioned MBs' size and US strength reduced SDM adhesion by about ~50% relative to systemic injection. Therefore, it can be concluded that drug delivery using the US field increases the SDM adhered to the whole AAA wall and decreases the SDM adhered to the critical wall of AAA.
Collapse
|
9
|
Takagi R, Yoshinaka K, Washio T, Koseki Y. A visualization method for a wide range of rising temperature induced by high-intensity focused ultrasound using a tissue-mimicking phantom. Int J Hyperthermia 2021; 39:22-33. [PMID: 34936844 DOI: 10.1080/02656736.2021.2012603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
PURPOSE High-intensity focused ultrasound (HIFU) treatment requires prior evaluation of the HIFU transducer output. A method using micro-capsulated thermochromic liquid crystal (MTLC) to evaluate the temperature distribution in the media during HIFU exposure has been previously developed. However, the color-coded temperature range of commercial MTLC is approximately 10 °C, which is insufficient for temperature measurement for HIFU exposure. We created two layers of tissue-mimicking phantoms with different color-coded temperature ranges, and a new visualization method was developed by utilizing the axisymmetric pressure distribution of a HIFU focus. METHODS A two-layer phantom with two sensitivity ranges was created. The HIFU transducer was set to align the focal point to the boundary between the two layers. Images of the upper and lower layers were flipped along the boundary between the two layers such that they overlapped with each other, assuming the pressure distribution of HIFU to be axisymmetric. RESULTS The experimental and simulation results were compared to evaluate the accuracy of the phantom temperature measurement. The experimental time profile of the temperature and spatial distribution around the HIFU focus matched well with that of the simulation. However, there is room for improvement in the accuracy in the axial direction of HIFU focus. CONCLUSION Users can apply our proposed method in clinical practice to promptly assess the output of the HIFU transducer before treatment.
Collapse
Affiliation(s)
- Ryo Takagi
- Medical Devices Research Group, Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
| | - Kiyoshi Yoshinaka
- Medical Devices Research Group, Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
| | - Toshikatsu Washio
- Medical Devices Research Group, Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
| | - Yoshihiko Koseki
- Medical Devices Research Group, Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
| |
Collapse
|
10
|
Ambrogio S, Baêsso RM, Bosio F, Fedele F, Ramnarine KV, Zeqiri B, Miloro P. A standard test phantom for the performance assessment of magnetic resonance guided high intensity focused ultrasound (MRgHIFU) thermal therapy devices. Int J Hyperthermia 2021; 39:57-68. [PMID: 34936852 DOI: 10.1080/02656736.2021.2017023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Purpose: Test objects for High Intensity Focused Ultrasound (HIFU) are required for the standardization and definition of treatment, Quality Assurance (QA), comparison of results between centers and calibration of devices. This study describes a HIFU test object which provides temperature measurement as a function of time, in a reference material compatible with Magnetic Resonance (MR) and ultrasound.Materials and methods: T-Type fine wire thermocouples were used as sensors and 5 correction methods for viscous heating artifacts were assessed. The phantom was tested in a MR-HIFU Philips Sonalleve device over a period of 12 months, demonstrating stability and validity to evaluate the performance of the device.Results: The study furnished useful information regarding the MR-HIFU sessions and highlighted potential limitations of the existing QA and monitoring methods. The importance of temperature monitoring along the whole acoustic path was demonstrated as MR Thermometry readings differed in the three MR plane views (coronal, sagittal, transverse), in particular when the focus was near a soft-tissue/bone interface, where there can be an MR signal loss with significant temperature and thermal dose underestimation (138% variation between the three plane views).Conclusions: The test object was easy to use and has potential as a valid tool for training, QA, research and development for MR guided HIFU and potentially ultrasound guided devices.
Collapse
Affiliation(s)
- S Ambrogio
- Medical Physics Department, Guy's and St Thomas' NHS Foundation Trust, London, UK.,Ultrasound and Underwater Acoustics Division, National Physical Laboratory, Teddington, UK
| | - R M Baêsso
- Ultrasound and Underwater Acoustics Division, National Physical Laboratory, Teddington, UK
| | - F Bosio
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - F Fedele
- Medical Physics Department, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - K V Ramnarine
- Medical Physics Department, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - B Zeqiri
- Ultrasound and Underwater Acoustics Division, National Physical Laboratory, Teddington, UK
| | - P Miloro
- Ultrasound and Underwater Acoustics Division, National Physical Laboratory, Teddington, UK
| |
Collapse
|
11
|
Ferdous S, Dopp JL, Reuel NF. Optimization of E. Coli Tip-Sonication for High-Yield Cell-Free Extract using Finite Element Modeling. AIChE J 2021; 67. [PMID: 35663841 DOI: 10.1002/aic.17389] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Optimal tip sonication settings, namely tip position, input power, and pulse durations, are necessary for temperature sensitive procedures like preparation of viable cell extract. In this paper, the optimum tip immersion depth (20-30% height below the liquid surface) is estimated which ensures maximum mixing thereby enhancing thermal dissipation of local cavitation hotspots. A finite element (FE) heat transfer model is presented, validated experimentally with (R2 > 97%) and used to observe the effect of temperature rise on cell extract performance of E. coli BL21 DE3 star strain and estimate the temperature threshold. Relative yields in the top 10% are observed for solution temperatures maintained below 32°C; this reduces below 50% relative yield at temperatures above 47°C. A generalized workflow for direct simulation using the COMSOL code as well as master plots for estimation of sonication parameters (power input and pulse settings) is also presented.
Collapse
Affiliation(s)
- Sakib Ferdous
- Department of Chemical and Biological Engineering Iowa State University Ames Iowa USA
| | - Jared L. Dopp
- Department of Chemical and Biological Engineering Iowa State University Ames Iowa USA
| | - Nigel F. Reuel
- Department of Chemical and Biological Engineering Iowa State University Ames Iowa USA
| |
Collapse
|
12
|
Payne A, Chopra R, Ellens N, Chen L, Ghanouni P, Sammet S, Diederich C, Ter Haar G, Parker D, Moonen C, Stafford J, Moros E, Schlesinger D, Benedict S, Wear K, Partanen A, Farahani K. AAPM Task Group 241: A medical physicist's guide to MRI-guided focused ultrasound body systems. Med Phys 2021; 48:e772-e806. [PMID: 34224149 DOI: 10.1002/mp.15076] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 04/28/2021] [Accepted: 06/21/2021] [Indexed: 11/07/2022] Open
Abstract
Magnetic resonance-guided focused ultrasound (MRgFUS) is a completely non-invasive technology that has been approved by FDA to treat several diseases. This report, prepared by the American Association of Physicist in Medicine (AAPM) Task Group 241, provides background on MRgFUS technology with a focus on clinical body MRgFUS systems. The report addresses the issues of interest to the medical physics community, specific to the body MRgFUS system configuration, and provides recommendations on how to successfully implement and maintain a clinical MRgFUS program. The following sections describe the key features of typical MRgFUS systems and clinical workflow and provide key points and best practices for the medical physicist. Commonly used terms, metrics and physics are defined and sources of uncertainty that affect MRgFUS procedures are described. Finally, safety and quality assurance procedures are explained, the recommended role of the medical physicist in MRgFUS procedures is described, and regulatory requirements for planning clinical trials are detailed. Although this report is limited in scope to clinical body MRgFUS systems that are approved or currently undergoing clinical trials in the United States, much of the material presented is also applicable to systems designed for other applications.
Collapse
Affiliation(s)
- Allison Payne
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Rajiv Chopra
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA
| | | | - Lili Chen
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA
| | - Pejman Ghanouni
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Steffen Sammet
- Department of Radiology, University of Chicago, Chicago, IL, USA
| | - Chris Diederich
- Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, USA
| | | | - Dennis Parker
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Chrit Moonen
- Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Jason Stafford
- Department of Imaging Physics, MD Anderson Cancer Center, Houston, TX, USA
| | - Eduardo Moros
- Department of Radiation Oncology, Moffitt Cancer Center, Tampa, FL, USA
| | - David Schlesinger
- Department of Radiation Oncology, University of Virginia, Charlottesville, VA, USA
| | | | - Keith Wear
- U.S. Food and Drug Administration, Silver Spring, MD, USA
| | | | - Keyvan Farahani
- National Cancer Institute, National Institutes of Health, Rockville, MD, USA
| |
Collapse
|
13
|
Sadeghi-Goughari M, Jeon S, Kwon HJ. Carbon nanotube-mediated high intensity focused ultrasound. NANO FUTURES 2021. [DOI: 10.1088/2399-1984/abfebc] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Abstract
High intensity focused ultrasound (HIFU) is emerging as a novel therapeutic technique for cancer treatment through a hyperthermal mechanism using ultrasound. However, collateral thermal damages to healthy tissue and skin burns due to the use of high levels of ultrasonic energy during HIFU treatment remain major challenges to clinical application. The main objective of the current study is to evaluate the potential of carbon nanotubes (CNTs) as effective absorption-enhancing agents for HIFU to mediate the heating process at low ultrasonic power levels, and consequently upgrade hyperthermal therapeutic effects of HIFU. An experimental study using in vitro tissue phantoms was conducted to assess the effects of CNTs on HIFU’s heating mechanism. Detailed information was extracted from the experiments for thermal analysis, including rate of absorbed energy density and temperature rise profile at the focal region. Parametric studies were carried out, revealing the effects of ultrasound parameters (ultrasonic power and driving frequency) on the performance of CNTs in various concentrations. The results indicated that CNTs significantly enhanced the thermal effect of HIFU by elevating energy absorption rate and consequential temperature rise. Moreover, it was demonstrated that an increase in ultrasonic power and driving frequency could lead to a better performance of CNTs during HIFU ablation procedures; the effects of CNTs could be further enhanced by increasing their volume concentration inside the medium.
Collapse
|
14
|
Sun S, Tang L, Zhao T, Kang Y, Sun L, Liu C, Li Y, Xu F, Qin YX, Ta D. Longitudinal effects of low-intensity pulsed ultrasound on osteoporosis and osteoporotic bone defect in ovariectomized rats. ULTRASONICS 2021; 113:106360. [PMID: 33561635 DOI: 10.1016/j.ultras.2021.106360] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Revised: 01/11/2021] [Accepted: 01/13/2021] [Indexed: 06/12/2023]
Abstract
Low-intensity pulsed ultrasound (LIPUS) with an intensity (spatial average temporal average, ISATA) of 30 mW/cm2 has been widely proved to be effective on impaired bone healing, but showing little effectiveness in the treatment of osteoporosis. We hypothesized that the intensity of LIPUS may be a key factor in explaining this difference, thus two intensity levels, the widely used 30 mW/cm2 and a higher 150 mW/cm2, were used to simultaneously treat osteoporosis and osteoporotic bone defect in ovariectomized (OVX) rats with a 1-mm drill hole on their left femurs.Results showed that 150 mW/cm2 LIPUS augmented the healing rate of the drill hole than 30 mW/cm2 after 3-week LIPUS treatment, although did not further enhance the healing rate after 6-week LIPUS treatment. For ameliorating osteoporosis, 150 mW/cm2 LIPUS achieved more advantages over 30 mW/cm2 in improving bone density, microstructure and biomechanics 6 weeks after LIPUS intervention. In conclusion, LIPUS with an intensity of 30 mW/cm2 was sufficient to facilitate bone defect healing, but a higher intensity can be considered as a rapid trigger for osteoporotic bone repair. In addition, improving the intensity of LIPUS may be a potentially effective consideration for alleviation of osteoporosis, and the LIPUS regimen in the treatment of osteoporosis remains to be optimized.
Collapse
Affiliation(s)
- Shuxin Sun
- Department of Electronic Engineering, Fudan University, Shanghai 200433, China
| | - Liang Tang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Tingting Zhao
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Yiting Kang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Lijun Sun
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, Shanghai 200433, China
| | - Ying Li
- Department of Electronic Engineering, Fudan University, Shanghai 200433, China
| | - Feng Xu
- Department of Electronic Engineering, Fudan University, Shanghai 200433, China
| | - Yi-Xian Qin
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281, United States
| | - Dean Ta
- Department of Electronic Engineering, Fudan University, Shanghai 200433, China; Academy for Engineering and Technology, Fudan University, Shanghai 200433, China.
| |
Collapse
|
15
|
Zou C, Harne RL. Deployable tessellated transducer array for ultrasound focusing and bio-heat generation in a multilayer environment. ULTRASONICS 2020; 104:106108. [PMID: 32145443 DOI: 10.1016/j.ultras.2020.106108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 12/14/2019] [Accepted: 02/18/2020] [Indexed: 06/10/2023]
Abstract
High intensity focused ultrasound (HIFU) has great potential to thermally ablate diseased tissues with minimal invasion. Yet, HIFU practice has limited cancer treatment potential since the absorption, diffusion, and reflection of ultrasound prevent HIFU from penetrating the body to deep and concealed diseased tissue. To explore a vision of deployable HIFU transducers, this research introduces an origami-inspired concept wherein a deployable tessellated acoustic array is employed to reduce the distance between the HIFU transducer and diseased tissues. A flat-foldable HIFU transducer array is considered, such that the compact shape is used to pass through the human body and then deployed into the operational form for treatment. Here a theoretical framework is developed to study the focusing and thermal heating capabilities of the tessellated array in a multilayer environment. It is observed that the wavefield and thermal elevation realized by the foldable array are functionally similar to those of an ideal arc-shaped transducer. Folding patterns that permit adequate curvature and high quality factor, and that balance slenderness and conformability are found to be beneficial for an ultrasound focusing practice. The efficacy of the analytical predictions are verified through direct numerical simulations. All together, the results encourage attention to foldable array concepts as potential means to advance in-vivo HIFU-based procedures.
Collapse
Affiliation(s)
- Chengzhe Zou
- Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Ryan L Harne
- Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH 43210, USA.
| |
Collapse
|
16
|
Sadeghi-Goughari M, Jeon S, Kwon HJ. Magnetic nanoparticles-enhanced focused ultrasound heating: size effect, mechanism, and performance analysis. NANOTECHNOLOGY 2020; 31:245101. [PMID: 32135521 DOI: 10.1088/1361-6528/ab7cea] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
High intensity focused ultrasound (HIFU) has attracted great interest as a new energy-based technique to treat disordered tissues, such as tumors, through a hyperthermal mechanism using ultrasonic waves. However, long treatment times and collateral damage to healthy tissues due to high acoustic powers are still challenges for the clinical application of HIFU. One possible strategy to enhance the deposition efficiency of HIFU at the tumor site is to employ magnetic nanoparticles (MNPs) as ultrasound absorption agents for the thermal therapy. The objectives of the current study are threefold: (i) to examine the effects of MNP features, including the size and volume concentration, on the thermal mechanism of HIFU (ii) to investigate the performance of MNPs as they were exposed to ultrasound fields at different ranges of power and frequency (iii) and to study the interaction mechanism between MNPs and ultrasonic waves during the MNPs-enhanced HIFU process. To this end, we developed an ultrasound-guided HIFU system to conduct an in vitro experimental study on tissue phantoms containing MNPs of different sizes and volume concentrations. A set of HIFU parameters such as temperature rise and the rate of absorbed energy was monitored to examine the role of MNPs during the NPs-enhanced HIFU thermal procedure. Results showed that the MNPs significantly improved the thermal effect of HIFU by enhancing the rate of energy converted to heat and the temperature rise at the focal region. Moreover, it was demonstrated that the increase of MNP size and volume concentration greatly enhanced the HIFU parameters; the effects of MNPs were further improved by increasing the power and frequency of acoustic field.
Collapse
Affiliation(s)
- Moslem Sadeghi-Goughari
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada
| | | | | |
Collapse
|
17
|
Cortela GA, Negreira CA, Pereira WCA. Durability study of a gellan gum-based tissue-mimicking phantom for ultrasonic thermal therapy. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:1531. [PMID: 32237853 DOI: 10.1121/10.0000813] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 02/12/2020] [Indexed: 06/11/2023]
Abstract
Stability and duration of ultrasonic phantoms are still subjects of research. This work presents a tissue-mimicking material (TMM) to evaluate high-intensity therapeutic ultrasound (HITU) devices, composed of gellan gum (matrix), microparticles (scatterers), and chemicals. The ultrasonic velocity and attenuation coefficient were characterized as a function of temperature (range 20 °C-85 °C). The nonlinear parameter B/A was determined by the finite amplitude insertion substitution (FAIS) method, and the shear modulus was determined by a transient elastography technique. The thermal conductivity and specific heat were determined by the line source method. The attenuation was stable for 60 days, and in an almost linear frequency dependence (0.51f0.96 dB cm-1), at 20 °C (1-10 MHz). All other evaluated physical parameters are also close to typical soft tissue values. Longitudinal ultrasonic velocities were between 1.49 and 1.75 mm μs-1, the B/A parameter was 7.8 at 30 °C, and Young's modulus was 23.4 kPa. The thermal conductivity and specific heat values were 0.7 W(m K)-1 and 4.7 kJ(kg K)-1, respectively. Consistent temperature increases and thermal doses occurred under identical HITU exposures. Low cost, longevity, thermal stability, and thermal repeatability make TMM an excellent material for ultrasonic thermal applications. The TMM developed has the potential to assess the efficacy of hyperthermia devices and could be used to adjust the ultrasonic emission of HITU devices.
Collapse
Affiliation(s)
- Guillermo A Cortela
- Institute of Physics, Faculty of Sciences, Universidad de la Republica Montevideo, Iguá 4225, 11400, Montevideo, Uruguay
| | - Carlos A Negreira
- Institute of Physics, Faculty of Sciences, Universidad de la Republica Montevideo, Iguá 4225, 11400, Montevideo, Uruguay
| | - Wagner C A Pereira
- Biomedical Engineering Program-COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| |
Collapse
|
18
|
Sadeghi-Goughari M, Jeon S, Kwon HJ. Analytical and Numerical Model of High Intensity Focused Ultrasound Enhanced With Nanoparticles. IEEE Trans Biomed Eng 2020; 67:3083-3093. [PMID: 32091987 DOI: 10.1109/tbme.2020.2975746] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE High intensity focused ultrasound (HIFU) is a new noninvasive therapeutics that allows local treatment of solid tumors through a hyperthermal mechanism using ultrasonic energy. One promising strategy to increase the thermal efficiency of HIFU is to employ nanoparticles (NPs) as ultrasound agents for the hyperthermia procedure. However, the interaction mechanism between NPs and ultrasonic waves has not been well understood. METHODS In an effort to investigate the heating process of NPs-enhanced HIFU, we derived a set of HIFU equations governing the temperature variation during the thermal ablation based on the principle of conservation of energy for heat transfer mechanism. A numerical model was developed to solve the HIFU equations to simulate the absorption mechanism of HIFU in the presence of NPs, the consequent heat transfer process, and the temperature rise profile during the sonication period. The accuracy of numerical model was verified by performing a series of experiments on tissue-mimicking phantoms embedded with magnetic NPs (MNPs). RESULTS The transport processes taking place at the boundaries between NPs and surrounding medium played the major role in the temperature rise during HIFU sonication. Besides, the effects of MNPs on rising temperature were improved by amplifying the ultrasonic power and frequency as well as by increasing the MNP concentration. CONCLUSION A quantitative comparison with experimental results demonstrated the potential of the numerical model to accurately predict the heating mechanism of HIFU mediated by NPs. SIGNIFICANCE The proposed method can help with simulation of HIFU when NPs are employed as ultrasound agents.
Collapse
|
19
|
Rezaeian M, Sedaghatkish A, Soltani M. Numerical modeling of high-intensity focused ultrasound-mediated intraperitoneal delivery of thermosensitive liposomal doxorubicin for cancer chemotherapy. Drug Deliv 2020; 26:898-917. [PMID: 31526065 PMCID: PMC6758722 DOI: 10.1080/10717544.2019.1660435] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Although intraperitoneal chemotherapy (IPC) has been suggested as a promising method for the management of peritoneal dissemination (PD) of ovarian or colorectal cancers, the actual clinical use of this method has been restricted due to such problems as poor drug penetration into the tumor and high side effects. It is, therefore, necessary to develop new strategies to improve the efficacy of this approach. In the present work, a new strategy is proposed based on intraperitoneal (IP) injection of thermosensitive liposomal doxorubicin (TSL-Dox) with triggered release by mild hyperthermia induced by high intensity focused ultrasound (HIFU). A computational model is developed to evaluate the proposed drug delivery system. Results show an order of magnitude increase in drug penetration depth into the tumor compared to the conventional IP delivery. Furthermore, the effects of thermal conditions applied to the tumor, TSL size, tumor vessel permeability, and tumor size are investigated. Results indicate an improved efficiency of the drug delivery by expanding the heated region, yet, it increases the risk of unintentional TSL drug load release in the peritoneal cavity. Results also indicate that smaller TSLs have better treatment outcome. However, there is a significant reduction in treatment efficacy for TSLs with sizes smaller than the vessel wall pore size. Thus, tuning the size of TSL should be based on the tumor microvascular permeability. The simulation results suggest that the TSL-Dox delivery system in smaller tumors is far advantageous than larger ones. Results of our model can be used as guidelines for future preclinical studies.
Collapse
Affiliation(s)
- Mohsen Rezaeian
- Department of Mechanical Engineering, K. N. Toosi University of Technology , Tehran , Iran
| | - Amir Sedaghatkish
- Department of Mechanical Engineering, Isfahan University of Technology , Isfahan , Iran
| | - M Soltani
- Department of Mechanical Engineering, K. N. Toosi University of Technology , Tehran , Iran.,Advanced Bioengineering Initiative Center, Computational Medicine Center, K. N. Toosi University of Technology , Tehran , Iran.,Department of Electrical and Computer Engineering, University of Waterloo , Waterloo , Canada.,Centre for Biotechnology and Bioengineering (CBB), University of Waterloo , Waterloo , Canada.,Cancer Biology Research Center, Cancer Institute of Iran, Tehran University of Medical Sciences , Tehran , Iran
| |
Collapse
|
20
|
He S, Tian Y, Feng S, Wu Y, Shen X, Chen K, He Y, Sun Q, Li X, Xu J, Wen Z, Qu JY. In vivo single-cell lineage tracing in zebrafish using high-resolution infrared laser-mediated gene induction microscopy. eLife 2020; 9:52024. [PMID: 31904340 PMCID: PMC7018510 DOI: 10.7554/elife.52024] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Accepted: 01/04/2020] [Indexed: 12/15/2022] Open
Abstract
Heterogeneity broadly exists in various cell types both during development and at homeostasis. Investigating heterogeneity is crucial for comprehensively understanding the complexity of ontogeny, dynamics, and function of specific cell types. Traditional bulk-labeling techniques are incompetent to dissect heterogeneity within cell population, while the new single-cell lineage tracing methodologies invented in the last decade can hardly achieve high-fidelity single-cell labeling and long-term in-vivo observation simultaneously. In this work, we developed a high-precision infrared laser-evoked gene operator heat-shock system, which uses laser-induced CreERT2 combined with loxP-DsRedx-loxP-GFP reporter to achieve precise single-cell labeling and tracing. In vivo study indicated that this system can precisely label single cell in brain, muscle and hematopoietic system in zebrafish embryo. Using this system, we traced the hematopoietic potential of hemogenic endothelium (HE) in the posterior blood island (PBI) of zebrafish embryo and found that HEs in the PBI are heterogeneous, which contains at least myeloid unipotent and myeloid-lymphoid bipotent subtypes. Animals begin life as a single cell that then divides to become a complex organism with many different types of cells. Every time a cell divides, each of its two daughter cells can either stay the same type as their parent or adopt a different identity. Once a cell acquires an identity, it usually cannot ‘go back’ and choose another. Eventually, this process will produce daughter cells with the identity of a specific tissue or organ and that cannot divide further. Multipotent cells are cells that can produce daughter cells with different identities, including other multipotent cells. These cells can usually give rise to different cell types in a specific organ, and generate more cells to replace any cells that die in that organ. Tracking the cells descended from a multipotent cell in a specific tissue can provide information about how the tissue develops. Hemogenic endothelium cells produce the multipotent cells that give rise to two types of white blood cells: myeloid cells and lymphoid cells. Myeloid cells include innate immune cells that protect the body from infection non-specifically; while lymphoid cells include T cells and B cells with receptors that detect specific bacteria or viruses. It remains unclear whether each of these two cell types originate from a single population of hemogenic endothelium cells or from two distinct subpopulations. He et al. have now developed a new optical technique to label a single hemogenic endothelium cell in a zebrafish and track the cell and its descendants. This method revealed that there are at least two distinct populations of hemogenic endothelium cells. One of them can give rise to both lymphoid and myeloid cells, while the other can only give rise to myeloid cells. These findings shed light on the mechanisms of blood formation, and potentially could provide useful tools to study the development of diseases such as leukemia. Additionally, the single-cell labeling technology He et al. have developed could be applied to study the development of other tissues and organs.
Collapse
Affiliation(s)
- Sicong He
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Kowloon, China.,State Key Laboratory of Molecular Neuroscience, The Hong Kong University of Science and Technology, Kowloon, China.,Center of Systems Biology and Human Health, The Hong Kong University of Science and Technology, Kowloon, China
| | - Ye Tian
- State Key Laboratory of Molecular Neuroscience, The Hong Kong University of Science and Technology, Kowloon, China.,Center of Systems Biology and Human Health, The Hong Kong University of Science and Technology, Kowloon, China.,Division of Life Science, The Hong Kong University of Science and Technology, Kowloon, China
| | - Shachuan Feng
- State Key Laboratory of Molecular Neuroscience, The Hong Kong University of Science and Technology, Kowloon, China.,Center of Systems Biology and Human Health, The Hong Kong University of Science and Technology, Kowloon, China.,Division of Life Science, The Hong Kong University of Science and Technology, Kowloon, China
| | - Yi Wu
- State Key Laboratory of Molecular Neuroscience, The Hong Kong University of Science and Technology, Kowloon, China.,Center of Systems Biology and Human Health, The Hong Kong University of Science and Technology, Kowloon, China.,Division of Life Science, The Hong Kong University of Science and Technology, Kowloon, China
| | - Xinwei Shen
- Department of Mathematics, The Hong Kong University of Science and Technology, Kowloon, China
| | - Kani Chen
- Department of Mathematics, The Hong Kong University of Science and Technology, Kowloon, China
| | - Yingzhu He
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Kowloon, China.,State Key Laboratory of Molecular Neuroscience, The Hong Kong University of Science and Technology, Kowloon, China.,Center of Systems Biology and Human Health, The Hong Kong University of Science and Technology, Kowloon, China
| | - Qiqi Sun
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Kowloon, China.,State Key Laboratory of Molecular Neuroscience, The Hong Kong University of Science and Technology, Kowloon, China.,Center of Systems Biology and Human Health, The Hong Kong University of Science and Technology, Kowloon, China
| | - Xuesong Li
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Kowloon, China.,State Key Laboratory of Molecular Neuroscience, The Hong Kong University of Science and Technology, Kowloon, China.,Center of Systems Biology and Human Health, The Hong Kong University of Science and Technology, Kowloon, China
| | - Jin Xu
- Division of Cell, Developmental and Integrative Biology, School of Medicine, South China University of Technology, Guangzhou, China
| | - Zilong Wen
- State Key Laboratory of Molecular Neuroscience, The Hong Kong University of Science and Technology, Kowloon, China.,Center of Systems Biology and Human Health, The Hong Kong University of Science and Technology, Kowloon, China.,Division of Life Science, The Hong Kong University of Science and Technology, Kowloon, China
| | - Jianan Y Qu
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Kowloon, China.,State Key Laboratory of Molecular Neuroscience, The Hong Kong University of Science and Technology, Kowloon, China.,Center of Systems Biology and Human Health, The Hong Kong University of Science and Technology, Kowloon, China
| |
Collapse
|
21
|
Andreozzi A, Iasiello M, Tucci C. An overview of mathematical models and modulated-heating protocols for thermal ablation. ACTA ACUST UNITED AC 2020. [DOI: 10.1016/bs.aiht.2020.07.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
22
|
Kamimura HAS, Aurup C, Bendau EV, Saharkhiz N, Kim MG, Konofagou EE. Iterative Curve Fitting of the Bioheat Transfer Equation for Thermocouple-Based Temperature Estimation In Vitro and In Vivo. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:70-80. [PMID: 31514131 PMCID: PMC6944748 DOI: 10.1109/tuffc.2019.2940375] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Temperature measurements with thin thermocouples embedded in ultrasound fields are strongly subjected to a viscous heating artifact (VHA). The artifact contribution decays over time; therefore, it can be minimized at late temperature readings. However, previous studies have failed to demonstrate a rigorous method for determining the optimal time point at which the artifact contribution is negligible. In this study, we present an iterative processing method based on successive curve fittings using an artifact-independent model. The fitting starting point moves at each iteration until the maximum R2 indicates where the viscous heating is minimum. A solution of the bioheat transfer equation is used to account for blood perfusion, thus enabling in vivo measurements. Three T-type thermocouples with different diameters and sensitivities were assessed in an excised canine liver and in the mouse brain in vivo. We found that the artifact constitutes up to 81% ± 5% of wire thermocouple readings. The best-fit time varied in the liver samples ( n = 3 ) from 0 to 3.335 ± 0.979 s and in the mouse brain ( n = 5 ) from 0 to 0.498 ± 0.457 s at variable experimental conditions, which clearly demonstrates the need of the method for finding the appropriate starting time point of the fit. This study introduces a statistical method to determine the best time to fit a curve that can back-estimate temperature in tissues under ultrasound exposure using thermocouples. This method allows temperature evaluation in vivo and in vitro during a validation and safety assessment of a wide range of therapeutic and diagnostic ultrasound modalities.
Collapse
|
23
|
Mohammadpour M, Firoozabadi B. Numerical study of the effect of vascular bed on heat transfer during high intensity focused ultrasound (HIFU) ablation of the liver tumor. J Therm Biol 2019; 86:102431. [DOI: 10.1016/j.jtherbio.2019.102431] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 08/30/2019] [Accepted: 10/04/2019] [Indexed: 01/20/2023]
|
24
|
Sadeghi-Goughari M, Jeon S, Kwon HJ. Enhancing Thermal Effect of Focused Ultrasound Therapy Using Gold Nanoparticles. IEEE Trans Nanobioscience 2019; 18:661-668. [PMID: 31449028 DOI: 10.1109/tnb.2019.2937327] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
High intensity focused ultrasound (HIFU) has gained increasing attention as a noninvasive therapeutic method for wide range of biomedical applications from drug delivery to cancer treatment. However, high level of ultrasonic power required for efficient HIFU treatment can cause adverse effects such as damage to surrounding healthy tissues and skin burns. One of the strategies to improve the therapeutic mechanism of HIFU is to use ultrasound absorption agents during the treatment. The objectives of current study are to investigate the feasibility of adopting gold nanoparticles (AuNPs) as ultrasound absorption agents to enhance the HIFU thermal ablation when the NPs were injected locally to the focal region; and to examine the dose effects of AuNPs on both heating and cooling mechanisms of HIFU. To this end, we conducted an experimental study on tissue-mimicking phantoms where AuNPs were injected to the focal region under the guidance of ultrasound imaging. A set of thermal parameters including temperature, specific absorption rate of acoustic energy, and cooling rate were measured to monitor the mechanism of AuNPs-mediated HIFU. The results suggest that both heating and cooling rates of HIFU procedure could be greatly improved by injecting AuNPs, which demonstrates the feasibility of using AuNPs to reduce the level of ultrasonic power from extracorporeal source for HIFU treatment.
Collapse
|
25
|
Abdolhosseinzadeh A, Mojra A, Ashrafizadeh A. A numerical study on thermal ablation of brain tumor with intraoperative focused ultrasound. J Therm Biol 2019; 83:119-133. [DOI: 10.1016/j.jtherbio.2019.05.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 05/13/2019] [Accepted: 05/19/2019] [Indexed: 02/07/2023]
|
26
|
Gnanaskandan A, Hsiao CT, Chahine G. Modeling of Microbubble-Enhanced High-Intensity Focused Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1743-1761. [PMID: 30982546 PMCID: PMC6555682 DOI: 10.1016/j.ultrasmedbio.2019.02.022] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Revised: 01/05/2019] [Accepted: 02/26/2019] [Indexed: 06/09/2023]
Abstract
Heat enhancement at the target in a high intensity focused ultrasound (HIFU) field is investigated by considering the effects of the injection of microbubbles in the vicinity of the tumor to be ablated. The interaction between the bubble cloud and the HIFU field is investigated using a 3-D numerical model. The propagation of non-linear ultrasonic waves in the tissue or in a phantom medium is modeled using the compressible Navier-Stokes equations on a fixed Eulerian grid, while the microbubbles dynamics and motion are modeled as discrete singularities, which are tracked in a Lagrangian framework. These two models are coupled to each other such that both the acoustic field and the bubbles influence each other. The resulting temperature rise in the field is calculated by solving a heat transfer equation applied over a much longer time scale. The compressible continuum part of the model is validated by conducting axisymmetric HIFU simulations without microbubbles and comparing the pressure and temperature fields against available experiments. The coupled Eulerian-Lagrangian approach is then validated against existing experiments conducted with a phantom tissue. The bubbles are distributed randomly in a 3-D fashion inside a cylindrical volume, while the background acoustic field is assumed axisymmetric. The presence of microbubbles modifies the ultrasound field in the focal region and significantly enhances heat deposition. The various mechanisms through which heat deposition is increased are then examined. Among these effects, viscous damping of the bubble oscillations is found to be the main contributor to the enhanced heat deposition. The effects of the initial void fraction in the cloud are then sought by considering the changes in the attenuation of the primary ultrasonic wave and the modifications of the enhanced heat deposition in the focal region. It is observed that although high bubble void fractions lead to increased heat deposition, they also cause significant pre-focal heating because of acoustic shielding. The effects of the microbubble cloud size and its location in the focal region are studied, and the effects of these parameters in altering the temperature rise and the location of the temperature peak are discussed. It is found that concentrating the bubbles adjacent to the focus and farther away from the acoustic source leads to effective heat deposition. Finally, the presence of a shell at the bubble surface, as in contrast agents, is seen to reduce heat deposition by restraining bubble oscillations.
Collapse
|
27
|
Tiennot T, Kamimura HAS, Lee SA, Aurup C, Konofagou EE. Numerical modeling of ultrasound heating for the correction of viscous heating artifacts in soft tissue temperature measurements. APPLIED PHYSICS LETTERS 2019; 114:203702. [PMID: 31148844 PMCID: PMC6530881 DOI: 10.1063/1.5091108] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Accepted: 05/06/2019] [Indexed: 05/27/2023]
Abstract
Measuring temperature during focused ultrasound (FUS) procedures is critical for characterization, calibration, and monitoring to ultimately ensure safety and efficacy. Despite the low cost and the high spatial and temporal resolutions of temperature measurements using thermocouples, the viscous heating (VH) artifact at the thermocouple-tissue interface requires reading corrections for correct thermometric analysis. In this study, a simulation pipeline is proposed to correct the VH artifact arising from temperature measurements using thermocouples in FUS fields. The numerical model consists of simulating a primary source of heating due to ultrasound absorption and a secondary source of heating from viscous forces generated by the thermocouple in the FUS field. Our numerical validation found that up to 90% of the measured temperature rise was due to VH effects. Experimental temperature measurements were performed using thermocouples embedded in fresh chicken breast samples. Temperature corrections were demonstrated for single high-intensity FUS pulses at 3.1 MHz and for multiple pulses (3.1 MHz, 100 Hz, and 500 Hz pulse repetition frequency). The VH accumulated during sonications and produced a temperature increase of 3.1 °C and 15.3 °C for the single and multiple pulse sequences, respectively. The methodology presented here enables the decoupling of the temperature increase generated by absorption and VH. Thus, more reliable temperature measurements can be extracted from thermocouple measurements by correcting for VH.
Collapse
Affiliation(s)
| | - Hermes A S Kamimura
- Department of Biomedical Engineering, Columbia University, New York, New York 10032, USA
| | - Stephen A Lee
- Department of Biomedical Engineering, Columbia University, New York, New York 10032, USA
| | - Christian Aurup
- Department of Biomedical Engineering, Columbia University, New York, New York 10032, USA
| | | |
Collapse
|
28
|
Hazlewood D, Yang X. Enhanced laser surface ablation with an integrated photoacoustic imaging and high intensity focused ultrasound system. Lasers Surg Med 2019; 51:616-624. [PMID: 30860297 DOI: 10.1002/lsm.23072] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/26/2019] [Indexed: 12/20/2022]
Abstract
BACKGROUND AND OBJECTIVE Combined laser and ultrasound treatments have been found to have synergistic effects, which may be of particular note in dermatology. We aim to investigate the potential of this technology for dermatology through in vitro and ex vivo experiments. METHODS In vitro tissue phantoms made of agar and tattoo ink and tattooed ex vivo chicken breast tissue were used. An integrated photoacoustic imaging and high intensity focused ultrasound (HIFU) system, using a 5-ns tunable OPO laser system and a 5 MHz HIFU transducer, was used to perform photoacoustic analysis to identify the optical contrast, and perform combined laser and ultrasound ablation. On the tissue phantoms, lines of ablation were created under various operating conditions. The samples were then quantified to determine the level of ablation. Same procedures were performed on the tattooed chicken breast tissue and the tattoo was removed by using combined laser and ultrasound. RESULTS Ablation in the in vitro tissue phantoms was observed with properly synchronized laser and ultrasound while no ablation was found with either laser or ultrasound alone. Increases to the intensity or pulse duration of ultrasound caused an increase in ablation to the samples. The tattoo was removed from the ex vivo chicken breast using combined laser and ultrasound with a radiant exposure of 1.2 J/cm2 while laser and ultrasound alone were unable to remove the tattoo. CONCLUSIONS We determined that by supplementing nanosecond laser pulses with ultrasound, ablation, and tattoo removal can be achieved at laser radiant exposures levels would otherwise be ineffective. The area of ablation can be adjusted through changes in the intensity and duration of the ultrasound burst with a constant laser intensity. Additionally, the system can be used to perform photoacoustic analysis of the tissue to estimate the relative optical absorbance at various available wavelengths, allowing for pretreatment analysis. Lasers Surg. Med. 9999:1-9, 2019. © 2019 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- David Hazlewood
- Bioengineering Program and Institute for Bioengineering Research, University of Kansas, Lawrence, Kansas
| | - Xinmai Yang
- Bioengineering Program and Institute for Bioengineering Research, University of Kansas, Lawrence, Kansas.,Department of Mechanical Engineering, University of Kansas, Lawrence, Kansas
| |
Collapse
|
29
|
Yang D, Ni Z, Yang Y, Xu G, Tu J, Guo X, Huang P, Zhang D. The enhanced HIFU-induced thermal effect via magnetic ultrasound contrast agent microbubbles. ULTRASONICS SONOCHEMISTRY 2018; 49:111-117. [PMID: 30057178 DOI: 10.1016/j.ultsonch.2018.07.031] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Revised: 07/06/2018] [Accepted: 07/23/2018] [Indexed: 06/08/2023]
Abstract
High intensity focused ultrasound (HIFU) has been regarded as a promising technology for treating cancer and other severe diseases noninvasively. In the present study, dual modality magnetic ultrasound contrast agent microbubbles (MBs) were synthesized by loading the super paramagnetic iron oxide nanoparticles (SPIOs) into the albumin-shelled MBs (referred as SPIO-albumin MBs). Then, both experimental measurements and numerical simulations were performed to evaluate the ability of SPIO-albumin MBs of enhancing HIFU-induced thermal effect. The results indicated that, comparing with regular albumin-shelled MBs, the SPIO-albumin MBs would lead to quicker temperature elevation rate and higher peak temperature. This phenomenon could be explained by the changes in MBs' physical and thermal properties induced by the integration of SPIOs into MB shell materials. In addition, more experimental results demonstrated that the enhancement effect on HIFU-induced temperature elevation could be further strengthened with more SPIOs combined with albumin-shell MBs. These observations suggested that more violent cavitation behaviors might be activated by ultrasound exposures with the presence of SPIOs, which in turn amplified ultrasound-stimulated thermal effect. Based on the present studies, it is reasonable to expect that, with the help of properly designed dual-modality magnetic MBs, the efficiency of HIFU-induced thermal effect could be further improved to achieve better therapeutic outcomes.
Collapse
Affiliation(s)
- Dongxin Yang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Zhengyang Ni
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Yanye Yang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Guangyao Xu
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Juan Tu
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China.
| | - Xiasheng Guo
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Pintong Huang
- Department of Ultrasound, The Second Affiliated Hospital of Zhejiang University, School of Medicine, Hangzhou 310009, China
| | - Dong Zhang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China; The State Key Laboratory of Acoustics, Chinese Academy of Science, Beijing 10080, China.
| |
Collapse
|
30
|
Hazlewood D, Feng Y, Lu Q, Wang J, Yang X. Treatment of post-traumatic joint contracture in a rabbit model using pulsed, high intensity laser and ultrasound. Phys Med Biol 2018; 63:205009. [PMID: 30196275 DOI: 10.1088/1361-6560/aadff0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Post-traumatic joint contracture induced by scar tissues following a surgery or injury can leave patients in a permanent state of pain and disability, which is difficult to resolve by current treatments. This randomized controlled trial examines the therapeutic effect of pulsed high-intensity laser (PHIL) and pulsed high-intensity focused ultrasound (PHIFU) for post-traumatic joint contracture due to arthrofibrosis. The peak power levels of both PHIL and PHIFU are much higher than that of laser or ultrasound currently used in physical therapy, while short pulses are utilized to prevent damage. To test the effectiveness of these treatments, a rabbit knee model for joint contracture was established. Twenty-one rabbits were split into four groups: untreated control (n = 5), PHIL (n = 5), PHIFU (n = 5), and a PHIL + PHIFU group (n = 6). Maximum extension of the surgically modified rabbit knee was compared to that of the contralateral control knee over the course of 16 weeks. The rabbits in the untreated control group maintained a relatively consistent level of joint contracture, while every rabbit in each of the treatment groups had improved range of motion, eventually leading to a restoration of normal joint extension. Average recovery time was 7.6 ± 1.5 weeks for the PHIL treatment group, 9.8 ± 3.7 weeks for the PHIFU group, and 8.0 ± 2.2 weeks for the combined treatment group. Histopathology demonstrated reduced density and accelerated resorption of scar tissues in the treated knee joints. This study provides evidence that both PHIL and PHIFU are effective in treating post-traumatic joint contracture in rabbits and warrant further investigation into the underlying mechanisms to optimize PHIL and PHIFU based treatments in a larger number of animals.
Collapse
Affiliation(s)
- David Hazlewood
- Bioengineering Program and Institute for Bioengineering Research, University of Kansas, Lawrence, KS, United States of America
| | | | | | | | | |
Collapse
|
31
|
Johnson SL, Christensen DA, Dillon CR, Payne A. Validation of hybrid angular spectrum acoustic and thermal modelling in phantoms. Int J Hyperthermia 2018; 35:578-590. [PMID: 30320518 PMCID: PMC6365205 DOI: 10.1080/02656736.2018.1513168] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 08/03/2018] [Accepted: 08/13/2018] [Indexed: 12/15/2022] Open
Abstract
In focused ultrasound (FUS) thermal ablation of diseased tissue, acoustic beam and thermal simulations enable treatment planning and optimization. In this study, a treatment-planning methodology that uses the hybrid angular spectrum (HAS) method and the Pennes' bioheat equation (PBHE) is experimentally validated in homogeneous tissue-mimicking phantoms. Simulated three-dimensional temperature profiles are compared to volumetric MR thermometry imaging (MRTI) of FUS sonications in the phantoms, whose acoustic and thermal properties are independently measured. Additionally, Monte Carlo (MC) uncertainty analysis is performed to quantify the effect of tissue property uncertainties on simulation results. The mean error between simulated and experimental spatiotemporal peak temperature rise was +0.33°C (+6.9%). Despite this error, the experimental temperature rise fell within the expected uncertainty of the simulation, as determined by the MC analysis. The average errors of the simulated transverse and longitudinal full width half maximum (FWHM) of the profiles were -1.9% and 7.5%, respectively. A linear regression and local sensitivity analysis revealed that simulated temperature amplitude is more sensitive to uncertainties in simulation inputs than in the profile width and shape. Acoustic power, acoustic attenuation and thermal conductivity had the greatest impact on peak temperature rise uncertainty; thermal conductivity and volumetric heat capacity had the greatest impact on FWHM uncertainty. This study validates that using the HAS and PBHE method can adequately predict temperature profiles from single sonications in homogeneous media. Further, it informs the need to accurately measure or predict patient-specific properties for improved treatment planning of ablative FUS surgeries.
Collapse
Affiliation(s)
- Sara L. Johnson
- Department of Bioengineering, University of Utah, Salt Lake City, UT, USA
| | - Douglas A. Christensen
- Department of Bioengineering, University of Utah, Salt Lake City, UT, USA
- Department of Computer and Electrical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Christopher R. Dillon
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Allison Payne
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
32
|
Zhou Y, Yu Z, Ma Q, Guo G, Tu J, Zhang D. Noninvasive Treatment-Efficacy Evaluation for HIFU Therapy Based on Magneto-Acousto-Electrical Tomography. IEEE Trans Biomed Eng 2018; 66:666-674. [PMID: 29993513 DOI: 10.1109/tbme.2018.2853594] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE As a novel noninvasive modality of oncotherapy or stroke treatment, high-intensity focused ultrasound (HIFU) has drawn more and more attention in the past decades. Whereas, real-time temperature monitoring and treatment-efficacy evaluation are still the key issues for HIFU therapy. METHODS Based on the temperature-conductivity relation of tissues with a sharp conductivity variation of irreversible thermocoagulation at 69 °C, a noninvasive method of treatment-efficacy evaluation for HIFU ablation using the magneto-acousto-electrical tomography (MAET) technology is theoretically studied. By applying the nonlinear Khokhlov-Zabolotskaya-Kuznetsov equation and Pennes equation, a cylindrical model is established to simulate the distributions of pressure, temperature, and conductivity with the consideration of harmonic components. RESULTS The MAET signals are simulated to analyze the characteristics of the peak amplitude and the axial interval of the two clusters generated by the conductivity boundary of HIFU ablation. CONCLUSION The axial interval can be used as the indictor to evaluate the size of HIFU ablation with the minimum axial width of one wavelength. SIGNIFICANCE The favorable results demonstrate the feasibility of real-time treatment-efficacy evaluation for HIFU therapy using the MAET technology and suggest potential applications in clinical practice.
Collapse
|
33
|
McCabe-Lankford EE, Brown TL, Levi-Polyachenko NH. Assessing fluorescence detection and effective photothermal therapy of near-infrared polymer nanoparticles using alginate tissue phantoms. Lasers Surg Med 2018; 50:1040-1049. [PMID: 29953621 DOI: 10.1002/lsm.22955] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/15/2018] [Indexed: 12/11/2022]
Abstract
OBJECTIVE Photothermal therapy (PTT) uses light absorbing materials to generate heat for treatment of diseases, like cancer. The advantages of using PTT components that absorb in the near-infrared (NIR) include reduced tissue auto-fluorescence and higher penetration depths. However, NIR laser light can still be scattered and absorbed by biological tissues, thus decreasing the amount of the energy reaching the PTT agents. We have developed two distinct formulations of NIR-absorbing nanoparticles, one which can be utilized for PTT only, and another for both PTT and fluorescence imaging of colorectal cancer. In this work, the fluorescence detection limit and the PTT heating potential of the two nanoparticle types were determined using alginate tissue phantoms. The objective of this study was to determine the PTT efficiency and theranostic potential of the nanoparticles by irradiating 3D collagen tumor spheroids, containing nanoparticles and CT26 mouse colorectal cancer cells, through increasing tissue phantom thicknesses and then quantifying cell death. Materials and Methods Our lab has previously developed nanoparticles based on the semiconducting, conjugated polymer poly[4,4-bis(2-ethylhexyl)-cyclopenta[2,1-b;3,4-b']dithiophene-2,6-diyl-alt-2,1,3-benzoselenadiazole-4,7-diyl] (PCPDTBSe). We have also made a hybrid nanoparticle that heats and fluoresces by combining PCPDTBSe polymer with the fluorescent poly[(9,9-dihexylfluorene)-co-2,1,3-benzothiadiazole-co-4,7-di(thiophen-2-yl)-2,1,3-benzothiadiazole] (PFBTDBT10) polymer to yield nanoparticles termed Hybrid Donor-Acceptor Polymer Particles (H-DAPPs). H-DAPPs and PCPDTBSe nanoparticles were added to three-dimensional collagen gel tumor spheroids in order to represent nanoparticles in a tumor. Alginate tissue phantoms, comprised of an optical scattering agent (Intralipid) and an optical absorbing material (hemoglobin) in order to mirror biological tissue scattering effects, were used to simulate increasing tissue thickness between the nanoparticles and the PTT energy source. RESULTS Fluorescence from the H-DAPPs was detectable through 6 mm of tissue phantoms. It was found that less than 10% of the laser energy could penetrate through 9 mm of tissue phantoms and only 60% of the laser energy passed through the 1.5 mm phantoms, regardless of laser power. PTT experiments, using 800 nm light at 2.2 W/cm2 for 60 s through tissue phantoms to stimulate nanoparticle-doped tumor spheroids, showed 55% cell death through 3 mm of tissue phantoms using H-DAPPs. Results from using the PCPDTBSe nanoparticles showed 72% cell death through 3 mm and over 50% cell death through 6 mm of tissue phantoms. CONCLUSION The results of this work validated the heating potential and fluorescence detection limitations of two theranostic polymer nanoparticles by utilizing alginate tissue phantoms and 3D tumor spheroids. H-DAPPs and PCPDTBSe polymer nanoparticles can be utilized as effective PTT agents by exploiting their absorption of NIR light and H-DAPPs have advantageous fluorescence for imaging colorectal cancer. The data generated from this study design can allow for other NIR absorbing and fluorescing nanoparticle formulations to be evaluated prior to in vivo experimentation. Lasers Surg. Med. 50:1040-1049, 2018. © 2018 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Eleanor E McCabe-Lankford
- Department of Plastic and Reconstructive Surgery, Wake Forest School of Medicine, Medical Center Boulevard, Winston-Salem, NC 27157
| | - Theodore L Brown
- Department of Plastic and Reconstructive Surgery, Wake Forest School of Medicine, Medical Center Boulevard, Winston-Salem, NC 27157
| | - Nicole H Levi-Polyachenko
- Department of Plastic and Reconstructive Surgery, Wake Forest School of Medicine, Medical Center Boulevard, Winston-Salem, NC 27157
| |
Collapse
|
34
|
Karaboce B, Cetin E, Durmus HO, Ozdingis M, Ozturk H, Mahmat K, Guler MA. Investigation of Different TMMs in High Intensity Focused Ultrasound Applications. 2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) 2018. [DOI: 10.1109/memea.2018.8438646] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
35
|
Haddadi S, Ahmadian MT. Numerical and Experimental Evaluation of High-Intensity Focused Ultrasound-Induced Lesions in Liver Tissue Ex Vivo. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:1481-1491. [PMID: 29193279 DOI: 10.1002/jum.14491] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 08/13/2017] [Accepted: 09/03/2017] [Indexed: 06/07/2023]
Abstract
OBJECTIVES Recent advances in the field of acoustics and piezoelectric and ultrasound transducers have led to new approaches to the diagnosis and treatment of certain diseases. One method of treatment with ultrasonic waves is high-intensity focused ultrasound (HIFU) treatment, which is a thermal therapeutic method used to treat malignant tumors. Although a variety of treatment-planning strategies using ultrasonic waves have been investigated, little clinical success has been achieved. Computational modeling is a powerful tool for predicting device performance. METHODS The heating induced by a concave transducer with operating powers of 85 and 135 W was studied, and the experimental results presented in this article verify its applicability. Numerical simulations of the nonlinear acoustic field were performed by using the Westervelt and Khokhlov-Zabolotskaya-Kuznetsov equations. Heat transfer was measured for the 2 operational powers, and the results were compared with ex vivo experimental results. In addition, thermal dose contours for both the simulation and experimental results were calculated to investigate the ablated area. RESULTS Good agreement was found between the experimental and numerical results. The results show that the average temperature deviations calculated at the focal point were 12.8% and 4.3% for transducer powers of 85 and 135 W, respectively. CONCLUSIONS This study provides guidance to HIFU practitioners in determining lesion size and identifying nonlinear effects that should be considered in HIFU procedures.
Collapse
Affiliation(s)
- Samaneh Haddadi
- School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Mohammad Taghi Ahmadian
- Center of Excellence in Design, Robotics, and Automation, School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| |
Collapse
|
36
|
Iwahashi T, Tang T, Matsui K, Fujiwara K, Itani K, Yoshinaka K, Azuma T, Takagi S, Sakuma I. Visualization of Temperature Distribution around Focal Area and Near Fields of High Intensity Focused Ultrasound Using a 3D Measurement System. ADVANCED BIOMEDICAL ENGINEERING 2018. [DOI: 10.14326/abe.7.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Affiliation(s)
| | | | | | | | | | - Kiyoshi Yoshinaka
- Health Research Institute, National Institute of Advanced Industrial Science and Technology
| | | | - Shu Takagi
- Department of Engineering, University of Tokyo
| | | |
Collapse
|
37
|
Song X, Qin Y, Xu Y, Ingram P, Witte RS, Dong F. Tissue Acoustoelectric Effect Modeling From Solid Mechanics Theory. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1583-1590. [PMID: 28692972 DOI: 10.1109/tuffc.2017.2724066] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The acoustoelectric (AE) effect is a basic physical phenomenon, which underlies the changes made in the conductivity of a medium by the application of focused ultrasound. Recently, based on the AE effect, several biomedical imaging techniques have been widely studied, such as ultrasound-modulated electrical impedance tomography and ultrasound current source density imaging. To further investigate the mechanism of the AE effect in tissue and to provide guidance for such techniques, we have modeled the tissue AE effect using the theory of solid mechanics. Both bulk compression and thermal expansion of tissue are considered and discussed. Computation simulation shows that the muscle AE effect result, conductivity change rate, is 3.26×10-3 with 4.3-MPa peak pressure, satisfying the theoretical value. Bulk compression plays the main role for muscle AE effect, while thermal expansion makes almost no contribution to it. In addition, the AE signals of porcine muscle are measured at different focal positions. With the same magnitude order and the same change trend, the experiment result confirms that the simulation result is effective. Both simulation and experimental results validate that tissue AE effect modeling using solid mechanics theory is feasible, which is of significance for the further development of related biomedical imaging techniques.
Collapse
|
38
|
Enhanced Energy Localization in Hyperthermia Treatment Based on Hybrid Electromagnetic and Ultrasonic System: Proof of Concept with Numerical Simulations. BIOMED RESEARCH INTERNATIONAL 2017; 2017:5787484. [PMID: 28840125 PMCID: PMC5559980 DOI: 10.1155/2017/5787484] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Revised: 05/17/2017] [Accepted: 06/18/2017] [Indexed: 12/31/2022]
Abstract
This paper proposes a hybrid hyperthermia treatment system, utilizing two noninvasive modalities for treating brain tumors. The proposed system depends on focusing electromagnetic (EM) and ultrasound (US) energies. The EM hyperthermia subsystem enhances energy localization by incorporating a multichannel wideband setting and coherent-phased-array technique. A genetic algorithm based optimization tool is developed to enhance the specific absorption rate (SAR) distribution by reducing hotspots and maximizing energy deposition at tumor regions. The treatment performance is also enhanced by augmenting an ultrasonic subsystem to allow focused energy deposition into deep tumors. The therapeutic faculty of ultrasonic energy is assessed by examining the control of mechanical alignment of transducer array elements. A time reversal (TR) approach is then investigated to address challenges in energy focus in both subsystems. Simulation results of the synergetic effect of both modalities assuming a simplified model of human head phantom demonstrate the feasibility of the proposed hybrid technique as a noninvasive tool for thermal treatment of brain tumors.
Collapse
|
39
|
Menikou G, Yiannakou M, Yiallouras C, Ioannides C, Damianou C. MRI-compatible breast/rib phantom for evaluating ultrasonic thermal exposures. Int J Med Robot 2017; 14. [DOI: 10.1002/rcs.1849] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Revised: 05/24/2017] [Accepted: 05/24/2017] [Indexed: 01/12/2023]
Affiliation(s)
| | | | - Christos Yiallouras
- Cyprus University of Technology; Limassol Cyprus
- MEDSONIC LTD; Limassol Cyprus
| | | | | |
Collapse
|
40
|
Peng HM, Zhu PC, Chen ZJ. Thermal analyses of in vitro low frequency sonophoresis. ULTRASONICS SONOCHEMISTRY 2017; 35:458-470. [PMID: 27838221 DOI: 10.1016/j.ultsonch.2016.10.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Revised: 10/28/2016] [Accepted: 10/28/2016] [Indexed: 06/06/2023]
Abstract
As a type of transdermal drug delivery method, low frequency sonophoresis (LFS) has been investigated during the last twenty years and is currently being attempted in a clinical setting. However, the safety of low frequency ultrasound on humans has not been completely guaranteed with high-intensity ultrasound. Thermal damage, one of the challenges in the LFS process, e.g., burns, epidermal detachment and necrosis of tissues, hinders its widespread applications. To predict and impede the overheating problems in LFS, an acoustic-flow-thermal finite element method (FEM) based on COMSOL Multiphysics software is proposed in this paper to achieve thermal analyses. The temperature distribution and its rising curves in in vitro LFS are obtained by the FEM method and experimental measurements. Both simulated and experimental maximum temperatures are larger than the safety value (e.g., 42°C on human tissues) when the driving voltage is higher than 40V (5.5W input electric power), which proves that the overheating problem really exists in high-intensity ultrasound. Furthermore, the results show that the calculated temperature rising curves in in vitro LFS correspond to the experimental results, proving the effectiveness of this FEM method. In addition, several potential thermal influence factors have been studied, including a duty ratio and amplitude of the driving voltage, and liquid height in the donor, which may be helpful in restraining the temperature increase to limit thermal damage. According to the calculated and experimental results, the former two factors are sensitive to the rise in temperature, but a small scale of liquid volume increase can enhance the permeation of Calcein without obvious temperature change. Hence, the above factors can be synthetically utilized to restrain the rise in temperature with little sacrifice of permeation ability. So this acoustic-flow-thermal FEM method could be applied to an optimized LFS system design and simulating the thermal analyses of LFS in healthy human body in terms of safe thermal limits.
Collapse
Affiliation(s)
- Han-Min Peng
- State Key Lab of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics & Astronautics, Nanjing 210016, China.
| | - Pan-Cheng Zhu
- State Key Lab of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics & Astronautics, Nanjing 210016, China
| | - Zhi-Jun Chen
- State Key Lab of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics & Astronautics, Nanjing 210016, China
| |
Collapse
|
41
|
Menikou G, Yiannakou M, Yiallouras C, Ioannides C, Damianou C. MRI-compatible bone phantom for evaluating ultrasonic thermal exposures. ULTRASONICS 2016; 71:12-19. [PMID: 27261569 DOI: 10.1016/j.ultras.2016.05.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Revised: 05/15/2016] [Accepted: 05/24/2016] [Indexed: 06/05/2023]
Abstract
OBJECTIVE The goal of the proposed study was the development of a magnetic resonance imaging (MRI) compatible bone phantom suitable for evaluating focused ultrasound protocols. MATERIALS AND METHODS High resolution CT images were used to segment femur bone. The segmented model was manufactured with (Acrylonitrile Butadiene Styrene) ABS plastic using a 3-D printer. The surrounding skeletal muscle tissue was mimicked using an agar-silica-evaporated milk gel (2% w/v-2% w/v-40% v/v). MR thermometry was used to evaluate the exposures of the bone phantom to focused ultrasound. RESULTS The estimated agar-silica-evaporated milk gel's T1 and T2 relaxation times in a 1.5T magnetic field were 776ms and 66ms respectively. MR thermometry maps indicated increased temperature adjacent to the bone, which was also shown in situations of real bone/tissue interfaces. CONCLUSION Due to growing interest of using MRI guided Focused Ultrasound Surgery (MRgFUS) in palliating bone cancer patients at terminal stages of the disease, the proposed bone phantom can be utilized as a very useful tool for evaluating ultrasonic protocols, thus minimizing the need for animal models. The estimated temperature measured and its distribution near the bone phantom/agar interface which was similar to temperatures recorded in real bone ablation with FUS, confirmed the phantom's functionality.
Collapse
Affiliation(s)
| | | | - Christos Yiallouras
- Cyprus University of Technology, Limassol, Cyprus; MEDSONIC LTD, Limassol, Cyprus
| | | | | |
Collapse
|
42
|
Schiavi A, Cuccaro R, Troia A. Strain-rate and temperature dependent material properties of Agar and Gellan Gum used in biomedical applications. J Mech Behav Biomed Mater 2016; 53:119-130. [DOI: 10.1016/j.jmbbm.2015.08.011] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2015] [Revised: 07/28/2015] [Accepted: 08/04/2015] [Indexed: 10/23/2022]
|
43
|
Hariharan P, Dibaji SAR, Banerjee RK, Nagaraja S, Myers MR. Localization of focused-ultrasound beams in a tissue phantom, using remote thermocouple arrays. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:2019-2031. [PMID: 25474777 DOI: 10.1109/tuffc.2014.006702] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
In focused-ultrasound procedures such as vessel cauterization or clot lysis, targeting accuracy is critical. To investigate the targeting accuracy of the focused-ultrasound systems, tissue phantoms embedded with thermocouples can be employed. This paper describes a method that utilizes an array of thermocouples to localize the focused ultrasound beam. All of the thermocouples are located away from the beam, so that thermocouple artifacts and sensor interference are minimized. Beam propagation and temperature rise in the phantom are simulated numerically, and an optimization routine calculates the beam location that produces the best agreement between the numerical temperature values and those measured with thermocouples. The accuracy of the method was examined as a function of the array characteristics, including the number of thermocouples in the array and their orientation. For exposures with a 3.3-MHz source, the remote-thermocouple technique was able to predict the focal position to within 0.06 mm. Once the focal location is determined using the localization method, temperatures at desired locations (including the focus) can be estimated from remote thermocouple measurements by curve fitting an analytical solution to the heat equation. Temperature increases in the focal plane were predicted to within 5% agreement with measured values using this method.
Collapse
|
44
|
Yang X, Jo J. Enhanced cavitation by using two consecutive ultrasound waves at different frequencies. APPLIED PHYSICS LETTERS 2014; 105:193701. [PMID: 25425746 PMCID: PMC4235622 DOI: 10.1063/1.4902118] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2014] [Accepted: 11/07/2014] [Indexed: 06/03/2023]
Abstract
Efficient and noninvasive generation of cavitation bubbles in soft tissue is a challenging task due to the lack of cavitation nuclei (i.e., pre-existing gas bubbles). In this study, we present a method to generate and enhance cavitation activity based on the utilization of two consecutive ultrasound waves at different frequencies. First, a high frequency (5 MHz) high intensity focused ultrasound (HIFU) wave was applied to a tissue-mimicking phantom to induce a rapid temperature rise in the ultrasound focal region. Immediately following the high frequency HIFU wave, a low frequency (1 MHz) HIFU wave was applied to the same focal region to induce acoustic cavitation. We found that cavitation activity was enhanced when the temperature in the tissue-mimicking phantom was first elevated by the high frequency HIFU wave. The enhancement was greater when a higher intensity of high frequency HIFU wave was applied. This result may be due to the temporary super-saturation of air in the initially air-saturated test samples and the reduction of surface tension at an elevated temperature.
Collapse
Affiliation(s)
- Xinmai Yang
- Department of Mechanical Engineering, The University of Kansas , 1530 W. 15th Street, 5109 Learned Hall, Lawrence, Kansas 66045, USA
| | - Janggun Jo
- Department of Mechanical Engineering, The University of Kansas , 1530 W. 15th Street, 5109 Learned Hall, Lawrence, Kansas 66045, USA
| |
Collapse
|
45
|
Dabbagh A, Abdullah BJJ, Ramasindarum C, Abu Kasim NH. Tissue-mimicking gel phantoms for thermal therapy studies. ULTRASONIC IMAGING 2014; 36:291-316. [PMID: 24626566 DOI: 10.1177/0161734614526372] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Tissue-mimicking phantoms that are currently available for routine biomedical applications may not be suitable for high-temperature experiments or calibration of thermal modalities. Therefore, design and fabrication of customized thermal phantoms with tailored properties are necessary for thermal therapy studies. A multitude of thermal phantoms have been developed in liquid, solid, and gel forms to simulate biological tissues in thermal therapy experiments. This article is an attempt to outline the various materials and techniques used to prepare thermal phantoms in the gel state. The relevant thermal, electrical, acoustic, and optical properties of these phantoms are presented in detail and the benefits and shortcomings of each type are discussed. This review could assist the researchers in the selection of appropriate phantom recipes for their in vitro study of thermal modalities and highlight the limitations of current phantom recipes that remain to be addressed in further studies.
Collapse
Affiliation(s)
- Ali Dabbagh
- Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur, Malaysia
| | - Basri Johan Jeet Abdullah
- Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur, Malaysia
| | - Chanthiriga Ramasindarum
- Biomaterials Technology Research Group, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia Dental Research Management Centre, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia
| | - Noor Hayaty Abu Kasim
- Biomaterials Technology Research Group, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
46
|
Doinikov AA, Novell A, Calmon P, Bouakaz A. Simulations and measurements of 3-D ultrasonic fields radiated by phased-array transducers using the westervelt equation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:1470-1477. [PMID: 25167147 DOI: 10.1109/tuffc.2014.3061] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The purpose of this work is to validate, by comparing numerical and experimental results, the ability of the Westervelt equation to predict the behavior of ultrasound beams generated by phased-array transducers. To this end, the full Westervelt equation is solved numerically and the results obtained are compared with experimental measurements. The numerical implementation of the Westervelt equation is performed using the explicit finite-difference time-domain method on a three-dimensional Cartesian grid. The validation of the developed numerical code is first carried out by using experimental data obtained for two different focused circular transducers in the regimes of small-amplitude and finite-amplitude excitations. Then, the comparison of simulated and measured ultrasonic fields is extended to the case of a modified 32-element array transducer. It is shown that the developed code is capable of correctly predicting the behavior of the main lobe and the grating lobes in the cases of zero and nonzero steering angles for both the fundamental and the second-harmonic components.
Collapse
|
47
|
Techniques to expand patient selection for MRI-guided high-intensity focused ultrasound ablation of uterine fibroids. AJR Am J Roentgenol 2014; 202:443-51. [PMID: 24450690 DOI: 10.2214/ajr.13.10753] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE MRI-guided high-intensity focused ultrasound (HIFU) ablation is increasingly adopted for treating symptomatic uterine fibroids. As a noninvasive therapy performed on an outpatient basis, it has been viewed by patients to have distinct advantages over other treatment options. However, its breadth of clinical application is still limited. To address this issue, various techniques have been implemented. CONCLUSION In this article, we discuss techniques that contribute to widening patient selection for MRI-guided HIFU therapy of uterine fibroids.
Collapse
|
48
|
Solovchuk MA, Hwang SC, Chang H, Thiriet M, Sheu TWH. Temperature elevation by HIFU inex vivoporcine muscle: MRI measurement and simulation study. Med Phys 2014; 41:052903. [DOI: 10.1118/1.4870965] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
|
49
|
Ahmad Reza Dibaji S, Al-Rjoub MF, Myers MR, Banerjee RK. Enhanced Heat Transfer and Thermal Dose Using Magnetic Nanoparticles During HIFU Thermal Ablation—An In-Vitro Study. J Nanotechnol Eng Med 2014. [DOI: 10.1115/1.4027340] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Avoiding collateral damage to healthy tissues during the high intensity focused ultrasound (HIFU) ablation of malignant tumors is one of the major challenges for effective thermal therapy. Such collateral damage can originate out of the need for using higher acoustic powers to treat deep seated or highly vascularized tumors. The objective of this study is to assess the utility of using magnetic nanoparticles (mNPs) during HIFU procedures to locally enhance heating at low powers, thereby reducing the likelihood of collateral thermal damage and undesired destruction due to cavitation. Tissue phantoms with 0% (control), 1% and 3% mNPs concentrations by volume were fabricated. Each tissue phantom was embedded with four thermocouples (TCs) and sonicated using transducer acoustic powers of 5.15 W, 9.17 W, and 14.26 W. The temperature profiles during the heating and cooling periods were recorded for each embedded TC. The measured transient temperature profiles were used for thermal-dose calculations. The increase in the concentration of mNPs in the tissue phantoms, from 0% to 3%, resulted in the rise in the peak temperatures for all the TCs for each acoustic power. The thermal dose also increased with the rise in the concentration of mNPs in the tissue phantoms. For the highest applied acoustic power (14.26 W), the peak temperature at TC 1 (T1) in tissue phantoms with 1% and 3% mNPs concentrations increased (with respect to tissue phantom with 0% (control) mNPs concentration) by 1.59× and 2.09×, respectively. For an acoustic power of 14.26 W, the time required to achieve cellular necrosis as defined by a 240 equivalent min thermal dose was approximately 75 s in the absence of mNPs, 14 s for the 1% concentration, and 8 s for the 3% concentration. Magnetic nanoparticles have the potential to significantly reduce the time for HIFU thermal-ablation procedures. They can also decrease the likelihood of collateral damage by the propagating beam in HIFU procedures by reducing the intensity required to achieve cellular necrosis.
Collapse
Affiliation(s)
- Seyed Ahmad Reza Dibaji
- Department of Mechanical and Materials Engineering, College of Engineering and Applied Science, University of Cincinnati, 2600 Clifton Avenue, Cincinnati, OH 45221
| | - Marwan F. Al-Rjoub
- Department of Mechanical and Materials Engineering, College of Engineering and Applied Science, University of Cincinnati, 2600 Clifton Avenue, Cincinnati, OH 45221
| | - Matthew R. Myers
- Division of Solid and Fluid Mechanics, Center for Devices and Radiological Health, U. S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993
| | - Rupak K. Banerjee
- Department of Mechanical and Materials Engineering, College of Engineering and Applied Science, University of Cincinnati, 598 Rhodes Hall, P.O. Box 210072, Cincinnati, OH 45221 e-mail:
| |
Collapse
|
50
|
Solovchuk MA, Sheu TWH, Thiriet M. Image-based computational model for focused ultrasound ablation of liver tumor. ACTA ACUST UNITED AC 2014. [DOI: 10.1186/2194-3990-1-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|