1
|
Hauser SN, Hustedt-Mai AR, Wichlinski A, Bharadwaj HM. The relationship between distortion product otoacoustic emissions and audiometric thresholds in the extended high-frequency range. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.07.05.601801. [PMID: 39026860 PMCID: PMC11257433 DOI: 10.1101/2024.07.05.601801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/20/2024]
Abstract
Distortion product otoacoustic emissions (DPOAEs) and behavioral audiometry are routinely used for hearing screening and assessment. These measures provide related information about hearing status as both are sensitive to cochlear pathologies. However, DPOAE testing is quicker and does not require a behavioral response. Despite these practical advantages, DPOAE testing is often limited to screening only low and mid- frequencies. Variation in ear canal acoustics across ears and probe placements has resulted in less reliable measurements of DPOAEs near 4 kHz and above where standing waves commonly occur. Stimulus calibration in forward pressure level and responses in emitted pressure level can reduce measurement variability. Using these calibrations, this study assessed the correlation between audiometry and DPOAEs in the extended high frequencies where stimulus calibrations and responses are most susceptible to the effect of standing waves. Behavioral thresholds and DPOAE amplitudes were negatively correlated, and DPOAE amplitudes in emitted pressure level accounted for twice as much variance as amplitudes in sound pressure level. Both measures were correlated with age. These data show that with appropriate calibration methods, extended high-frequency DPOAEs are sensitive to differences in audiometric thresholds and highlight the need to consider calibration techniques in clinical and research applications of DPOAEs.
Collapse
Affiliation(s)
- Samantha N. Hauser
- Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN 47901, USA
| | | | - Anna Wichlinski
- Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN 47901, USA
| | - Hari M. Bharadwaj
- Communication Science and Disorders, University of Pittsburgh, Pittsburgh, PA 15260, USA
| |
Collapse
|
2
|
Urichuk M, Purcell D, Scollie S. Validity and reliability of integrated pressure level real-ear-to-coupler difference measurements. Int J Audiol 2024; 63:401-410. [PMID: 37129231 DOI: 10.1080/14992027.2023.2205009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 04/06/2023] [Indexed: 05/03/2023]
Abstract
OBJECTIVES (1) To validate the measurement of foam-tip real-ear-to-coupler differences (wRECD) using an integrated pressure level (IPL) method and (2) to compare the reliability of this method to SPL-based measurement of the wRECD. DESIGN SPL-based wRECD and the proposed IPL wRECD measurement were completed bilaterally. Test-retest reliability of IPL wRECD was determined with full re-insertion into the ear canal and compared to published SPL wRECD test-retest data. STUDY SAMPLE 22 adults with normal hearing and middle ear status were recruited. RESULTS Differences between SPL-based wRECD and IPL wRECD measurements were within 1.51 dB on average below 5000 Hz. At and above 5000 Hz, IPL wRECD exceeded SPL wRECDs by 6.11 dB on average. The average test-retest difference for IPL wRECD across all assessed frequencies was 0.75 dB with the greatest improvements in reliability found below 750 Hz and above 3000 Hz. CONCLUSIONS IPL wRECD yielded improved estimates compared to SPL wRECD in high frequencies, where standing-wave interference is present. Independence from standing wave interference resulted in increased wRECD values above 4000 Hz using the IPL measurement paradigm. IPL wRECD is more reliable than SPL wRECD, does not require precise probe-microphone placement, and provides a wider valid wRECD bandwidth than SPL-based measurement.
Collapse
Affiliation(s)
- Matthew Urichuk
- School of Communication Sciences and Disorders, Western University, London, Ontario, Canada
- Health and Rehabilitation Sciences Graduate Program, Western University, London, Ontario, Canada
| | - David Purcell
- School of Communication Sciences and Disorders, Western University, London, Ontario, Canada
- Health and Rehabilitation Sciences Graduate Program, Western University, London, Ontario, Canada
- National Center for Audiology, Western University, London, Ontario, Canada
| | - Susan Scollie
- School of Communication Sciences and Disorders, Western University, London, Ontario, Canada
- Health and Rehabilitation Sciences Graduate Program, Western University, London, Ontario, Canada
- National Center for Audiology, Western University, London, Ontario, Canada
| |
Collapse
|
3
|
Bader K, Dalhoff E, Dierkes L, Braun LH, Gummer AW, Zelle D. Reliable Long-Term Serial Evaluation of Cochlear Function Using Pulsed Distortion-Product Otoacoustic Emissions: Analyzing Levels and Pressure Time Courses. Ear Hear 2024:00003446-990000000-00284. [PMID: 38809242 DOI: 10.1097/aud.0000000000001522] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2024]
Abstract
OBJECTIVES To date, there is no international standard on how to use distortion-product otoacoustic emissions (DPOAEs) in serial measurements to accurately detect changes in the function of the cochlear amplifier due, for example, to ototoxic therapies, occupational noise, or the development of regenerative therapies. The use of clinically established standard DPOAE protocols for serial monitoring programs appears to be hampered by multiple factors, including probe placement and calibration effects, signal-processing complexities associated with multiple sites of emission generation as well as suboptimal selection of stimulus parameters. DESIGN Pulsed DPOAEs were measured seven times within 3 months for f2 = 1 to 14 kHz and L2 = 25 to 80 dB SPL in 20 ears of 10 healthy participants with normal hearing (mean age = 32.1 ± 9.7 years). L1 values were computed from individual optimal-path parameters derived from the corresponding individual DPOAE level map in the first test session. Three different DPOAE metrics for evaluating the functional state of the cochlear amplifier were investigated with respect to their test-retest reliability: (1) the interference-free, nonlinear-distortion component level (LOD), (2) the time course of the DPOAE-envelope levels, LDP(t), and (3) the squared, zero-lag correlation coefficient () between the time courses of the DPOAE-envelope pressures, pDP(t), measured in two sessions. The latter two metrics include the two main DPOAE components and their state of interference. RESULTS Collated over all sessions and frequencies, the median absolute difference for LOD was 1.93 dB and for LDP(t) was 2.52 dB; the median of was 0.988. For the low (f2 = 1 to 3 kHz), mid (f2 = 4 to 9 kHz), and high (f2 = 10 to 14 kHz) frequency ranges, the test-retest reliability of LOD increased with increasing signal to noise ratio (SNR). CONCLUSIONS On the basis of the knowledge gained from this study on the test-retest reliability of pulsed DPOAE signals and the current literature, we propose a DPOAE protocol for future serial monitoring applications that takes into account the following factors: (1) separation of DPOAE components, (2) use of individually optimal stimulus parameters, (3) SNR of at least 15 dB, (4) accurate pressure calibration, (5) consideration of frequency- and level-dependent test-retest reliabilities and corresponding reference ranges, and (6) stimulus levels L2 that are as low as possible with sufficient SNR to capture the nonlinear functional state of the cochlear amplifier operating at its highest gain.
Collapse
Affiliation(s)
- Katharina Bader
- Department of Otolaryngology, Head and Neck Surgery, Eberhard-Karls-University Tübingen, Tübingen, Germany
| | - Ernst Dalhoff
- Section of Physiological Acoustics and Communication, Department of Otolaryngology, Eberhard-Karls-University Tübingen, Tübingen, Germany
| | - Linda Dierkes
- Department of Otolaryngology, Head and Neck Surgery, Eberhard-Karls-University Tübingen, Tübingen, Germany
- Section of Physiological Acoustics and Communication, Department of Otolaryngology, Eberhard-Karls-University Tübingen, Tübingen, Germany
| | - Lore Helene Braun
- Department of Radiooncology, Eberhard-Karls-University Tübingen, Tübingen, Germany
| | - Anthony W Gummer
- Section of Physiological Acoustics and Communication, Department of Otolaryngology, Eberhard-Karls-University Tübingen, Tübingen, Germany
| | - Dennis Zelle
- Section of Physiological Acoustics and Communication, Department of Otolaryngology, Eberhard-Karls-University Tübingen, Tübingen, Germany
- Earlab GmbH, Tübingen, Germany
| |
Collapse
|
4
|
Hannon C, Lewis JD. Effects of Tympanic Membrane Electrodes on Sound Transmission From the Ear Canal to the Middle and Inner Ears. Ear Hear 2024:00003446-990000000-00276. [PMID: 38764148 DOI: 10.1097/aud.0000000000001524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/21/2024]
Abstract
OBJECTIVES The first objective of the study was to compare approaches to eardrum electrode insertion as they relate to the likelihood of introducing an acoustic leak between the ear canal and eartip. A common method for placing a tympanic membrane electrode involves securing the electrode in the canal by routing it underneath a foam eartip. This method is hypothesized to result in a slit leak between the canal and foam tip due to the added bulk of the electrode wire. An alternative approach involves creating a bore in the wall of the foam tip that the electrode can be threaded through. This method is hypothesized to reduce the likelihood of a slit leak before the electrode wire is integrated into the foam tip. The second objective of the study was to investigate how sound transmission in the ear is affected by placing an electrode on the eardrum. It was hypothesized that an electrode in contact with the eardrum increases the eardrum's mass, with the potential to reduce sound transmission at high frequencies. DESIGN Wideband acoustic immittance and distortion product otoacoustic emissions (DPOAEs) were measured in eight human ears. Measurements were completed for five different conditions: (1) baseline with no electrode in the canal, (2) dry electrode in the canal but not touching the eardrum, secured underneath the eartip, (3) dry electrode in the canal not touching the eardrum, secured through a bore in the eartip (subsequent conditions were completed using this method), (4) hydrated electrode in the canal but not touching the eardrum, and (5) hydrated electrode touching the eardrum. To create the bore, a technique was developed in which a needle is heated and pushed through the foam eartip. The electrode is then thread through the bore and advanced slowly by hand until contacting the eardrum. Analysis included comparing absorbance, admittance phase angle, and DPOAE levels between measurement conditions. RESULTS Comparison of the absorbance and admittance phase angle measurements between the electrode placement methods revealed significantly higher absorbance and lower admittance phase angle from 0.125 to 1 kHz when the electrode is routed under the eartip. Absorbance and admittance phase angle were minimally affected when the electrode was inserted through a bore in the eartip. DPOAE levels across the different conditions showed changes approximating test-retest variability. Upon contacting the eardrum, the absorbance tended to decrease below 1 kHz and increase above 1 kHz. However, changes were within the range of test-retest variability. There was evidence of reduced levels below 1 kHz and increased levels above 1 kHz upon the electrode contacting the eardrum. However, differences between conditions approximated test-retest variability. CONCLUSIONS Routing the eardrum electrode through the foam tip reduces the likelihood of incurring an acoustic leak between the canal walls and eartip, compared with routing the electrode under the eartip. Changes in absorbance and DPOAE levels resulting from electrode contact with the eardrum implicate potential stiffening of eardrum; however, the magnitude of changes suggests minimal effect of the electrode on sound transmission in the ear.
Collapse
Affiliation(s)
- Cailin Hannon
- Department of Audiology and Speech Pathology, University of Tennessee Health Science Center, Knoxville, Tennessee, USA
| | | |
Collapse
|
5
|
Nørgaard KM, Motallebzadeh H, Puria S. The influence of tympanic-membrane orientation on acoustic ear-canal quantities: A finite-element analysis. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2769-2785. [PMID: 38662609 PMCID: PMC11052631 DOI: 10.1121/10.0025768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 02/23/2024] [Accepted: 04/01/2024] [Indexed: 04/28/2024]
Abstract
Assuming plane waves, ear-canal acoustic quantities, collectively known as wideband acoustic immittance (WAI), are frequently used in research and in the clinic to assess the conductive status of the middle ear. Secondary applications include compensating for the ear-canal acoustics when delivering stimuli to the ear and measuring otoacoustic emissions. However, the ear canal is inherently non-uniform and terminated at an oblique angle by the conical-shaped tympanic membrane (TM), thus potentially confounding the ability of WAI quantities in characterizing the middle-ear status. This paper studies the isolated possible confounding effects of TM orientation and shape on characterizing the middle ear using WAI in human ears. That is, the non-uniform geometry of the ear canal is not considered except for that resulting from the TM orientation and shape. This is achieved using finite-element models of uniform ear canals terminated by both lumped-element and finite-element middle-ear models. In addition, the effects on stimulation and reverse-transmission quantities are investigated, including the physical significance of quantities seeking to approximate the sound pressure at the TM. The results show a relatively small effect of the TM orientation on WAI quantities, except for a distinct delay above 10 kHz, further affecting some stimulation and reverse-transmission quantities.
Collapse
Affiliation(s)
- Kren Monrad Nørgaard
- Interacoustics Research Unit, 2800 Kongens Lyngby, Denmark
- Interacoustics A/S, 5500 Middelfart, Denmark
| | - Hamid Motallebzadeh
- Department of Communication Sciences & Disorders, California State University, Sacramento, California 95819, USA
- Department of Biomedical Engineering, McGill University, Montréal, Quebec H3A 2B4, Canada
| | - Sunil Puria
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, Massachusetts 02114, USA
- Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts 02115, USA
- Graduate Program in Speech and Hearing Bioscience and Technology, Harvard University, Cambridge, Massachusetts 02138, USA
| |
Collapse
|
6
|
Lapsley Miller JA, Reed CM, Marshall L, Perez ZD, Villabona T. A Clinically Viable Medial Olivocochlear Reflex Assay Using Transient-Evoked Otoacoustic Emissions. Ear Hear 2024; 45:115-129. [PMID: 37475147 DOI: 10.1097/aud.0000000000001406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/22/2023]
Abstract
OBJECTIVES The contralateral medial olivocochlear reflex (MOCR) strength may indicate various auditory conditions in humans, but a clinically viable assay and equipment are needed for quick, accurate, and reliable measurements. The first experiment compared an earlier version of the assay, which used a nonlinear-mode chirp stimulus, with a new assay using a linear-mode click stimulus, designed to give reliable MOCR measurements in most normal-hearing ears. The second experiment extended the improved assay on a purpose-built binaural hardware platform that used forward-pressure level (FPL) calibration for both the stimulus and the contralateral MOCR elicitor. DESIGN Transient-evoked otoacoustic emission (TEOAE) tests were measured with and without a 60-dB SPL MOCR-evoking contralateral broadband noise. The normalized MOCR strength (MOCR%) was derived from the TEOAE responses for each trial pair using the complex pressure difference weighted by the TEOAE magnitude. Experiment 1 compared MOCR% within-subject and across-day using two TEOAE stimuli: nonlinear-mode chirps (50 dB SPL, bandpass 1-5 kHz, 14 ms window delayed by 2 ms) and linear-mode clicks (50 dB SPL, bandpass 0.5-2.5 kHz, 13 ms window delayed by 5 ms). TEOAE responses were analyzed in the 0.5 to 2.5 kHz band. Thirty adult participants with normal hearing (30 ears) completed the study. The TEOAE stimulus was calibrated in situ using spectral flattening, and the contralateral noise was calibrated in a coupler. Twelve TEOAE trial pairs were collected for each participant and condition. Experiment 2 used a purpose-built binaural system. The TEOAE stimuli were linear-mode clicks (50 dB SPL, bandpass 1-3 kHz, 13 ms window delayed by 5 ms), analyzed in the 1 to 3 kHz band over ~12 trial pairs. After a probe refit, an additional trial pair was collected for the two early-stopping signal-to-noise ratio criteria (15 and 20 dB). They were evaluated for single-trial reliability and test time. Nineteen adult participants with normal hearing (38 ears) completed the study. The TEOAE clicks and contralateral elicitor noise were calibrated in situ using FPL and delivered with automated timing. RESULTS MOCR% for linear-mode clicks was distinguishable from measurement variability in 98% to 100% of participants' ears (both experiments), compared with only 73% for the nonlinear-mode chirp (experiment 1). MOCR detectability was assessed using the MOCR% across-subject/within-subject variance ratio. The ratio in experiment 1 for linear-mode clicks was higher (8.0) than for nonlinear-mode chirps (6.4). The ratio for linear-mode clicks (8.9) in experiment 2 was slightly higher than for the comparable linear-mode stimulus (8.0) in experiment 1. TEOAEs showed excellent reliability with high signal-to-noise ratios in both experiments, but reliability was higher for linear-mode clicks than nonlinear-mode chirps. MOCR reliability for the two stimuli was comparable. The FPL pressure response retest reliability derived from the SPL at the microphone was higher than the SPL retest reliability across 0.4 to 8 kHz. Stable results required 2 to 3 trial pairs for the linear-mode click (experiments 1 and 2) and three for the nonlinear-mode chirp (experiment 1), taking around 2 min on average. CONCLUSIONS The linear-mode click assay produced measurable, reliable, and stable TEOAE and MOCR results on both hardware platforms in around 2 min per ear. The stimulus design and response window ensured that any stimulus artifact in linear mode was unlikely to confound the results. The refined assay is ready to produce high-quality data quickly for clinical and field studies to develop population norms, recognize diagnostic patterns, and determine risk profiles.
Collapse
Affiliation(s)
- Judi A Lapsley Miller
- Mimosa Acoustics, Champaign, Illinois, USA
- Naval Submarine Medical Research Laboratory, Groton, Connecticut, USA
| | - Charlotte M Reed
- Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Lynne Marshall
- Naval Submarine Medical Research Laboratory, Groton, Connecticut, USA
| | - Zachary D Perez
- Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Timothy Villabona
- Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| |
Collapse
|
7
|
Stiepan S, Shera CA, Abdala C. Characterizing a Joint Reflection-Distortion OAE Profile in Humans With Endolymphatic Hydrops. Ear Hear 2023; 44:1437-1450. [PMID: 37450653 PMCID: PMC10593104 DOI: 10.1097/aud.0000000000001387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/18/2023]
Abstract
OBJECTIVES Endolymphatic hydrops (EH), a hallmark of Meniere disease, is an inner-ear disorder where the membranes bounding the scala media are distended outward due to an abnormally increased volume of endolymph. In this study, we characterize the joint-otoacoustic emission (OAE) profile, a results profile including both distortion- and reflection-class emissions from the same ear, in individuals with EH and speculate on its potential utility in clinical assessment and monitoring. DESIGN Subjects were 16 adults with diagnosed EH and 18 adults with normal hearing (N) matched for age. Both the cubic distortion product (DP) OAE, a distortion-type emission, and the stimulus-frequency (SF) OAE, a reflection-type emission, were measured and analyzed as a joint OAE profile. OAE level, level growth (input/output functions), and phase-gradient delays were measured at frequencies corresponding to the apical half of the human cochlea and compared between groups. RESULTS Normal hearers and individuals with EH shared some common OAE patterns, such as the reflection emissions being generally higher in level than distortion emissions and showing more linear growth than the more strongly compressed distortion emissions. However, significant differences were noted between the EH and N groups as well. OAE source strength (a metric based on OAE amplitude re: stimulus level) was significantly reduced, as was OAE level, at low frequencies in the EH group. These reductions were more marked for distortion than reflection emissions. Furthermore, two significant changes in the configuration of OAE input/output functions were observed in ears with EH: a steepened growth slope for reflection emissions and an elevated compression knee for distortion emissions. SFOAE phase-gradient delays at 40 dB forward-pressure level were slightly shorter in the group with EH compared with the normal group. CONCLUSIONS The underlying pathology associated with EH impacts the generation of both emission types, reflection and distortion, as shown by significant group differences in OAE level, growth, and delay. However, hydrops impacts reflection and distortion emissions differently. Most notably, DPOAEs were more reduced by EH than were SFOAEs, suggesting that pathologies associated with the hydropic state do not act identically on the generation of nonlinear distortion at the hair bundle and intracochlear reflection emissions near the peak of the traveling wave. This differential effect underscores the value of applying a joint OAE approach to access both intracochlear generation processes concurrently.
Collapse
Affiliation(s)
- Samantha Stiepan
- Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, CA 90033, USA
| | - Christopher A Shera
- Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, CA 90033, USA
- Department of Physics and Astronomy, University of Southern California, Los Angeles, CA 90089, USA
| | - Carolina Abdala
- Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, CA 90033, USA
| |
Collapse
|
8
|
Nørgaard KM. A reference for ear-canal absorbance based on semi-anechoic waveguides. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 154:2227-2235. [PMID: 37815411 DOI: 10.1121/10.0021313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 09/21/2023] [Indexed: 10/11/2023]
Abstract
Wideband acoustic immittance (WAI), in particular, ear-canal absorbance, is a useful clinical tool for assessing the middle-ear status and diagnosing conductive hearing disorders. However, little evidence documents the measurement accuracy of WAI in human ears, and, because its clinical adoption is still in its infancy, no international standards exist to define appropriate requirements for commercial instrumentation. A challenge from a standardization point of view is the lack of an absorbance reference, i.e., an acoustic load similar to the adult ear canal with a known absorbance. This paper explores various approaches to providing such an acoustic load to quantify WAI measurement accuracy. The approaches considered here include standardized and inexpensive occluded-ear simulators, and a family of semi-anechoic waveguides with different step discontinuities in cross-sectional area. These semi-anechoic waveguides could be included in a future WAI standard. In addition, a means of monitoring the stability of WAI calibrations over time is proposed, utilizing a single inexpensive occluded-ear simulator.
Collapse
|
9
|
McCreery RW, Grindle A, Merchant GR, Crukley J, Walker EA. Predicting wideband real-ear-to-coupler differences in children using wideband acoustic immittance. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 154:991-1002. [PMID: 37581511 PMCID: PMC10431946 DOI: 10.1121/10.0020660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 07/24/2023] [Accepted: 07/30/2023] [Indexed: 08/16/2023]
Abstract
Individual differences in ear-canal acoustics introduce variability into hearing aid output that can affect speech audibility. Measuring ear-canal acoustics in young children can be challenging, and relying on normative real-ear-to-coupler difference (RECD) transforms can lead to large fitting errors. Acoustic immittance measures characterize the impedance of the ear and are more easily measured than RECD. Using 226 Hz tympanometry to predict the RECD is more accurate than using age-based average RECD values. The current study sought to determine whether wideband acoustic immittance measurements could improve predictions of wideband real-ear-to-coupler difference (wRECD). 150 children ages 2-10 years with intact tympanic membranes underwent wRECD and wideband acoustic immittance measures in each ear. Three models were constructed to predict each child's measured wRECD: the age-based average wRECD, 226 Hz admittance wRECD, and wideband absorbance wRECD. The average age-based wRECD model predicted the child's measured wRECD within 3 dB in 62% of cases, but both the 226 Hz admittance and wideband absorbance wRECD were within 3 dB in 90% of cases. Using individual 226 Hz or wideband absorbance to predict wRECD improved the accuracy and precision of transforms used for pediatric hearing aid fitting.
Collapse
Affiliation(s)
- Ryan W McCreery
- Audibility, Perception, and Cognition Laboratory, Boys Town National Research Hospital, Omaha, Nebraska 68131, USA
| | - Anastasia Grindle
- Pediatric Audiology, UW Health American Family Children's Hospital, Madison, Wisconsin 53792, USA
| | - Gabrielle R Merchant
- Translational Auditory Physiology and Perception Laboratory, Boys Town National Research Hospital, Omaha, Nebraska 68131, USA
| | - Jeffery Crukley
- Faculty of Medicine, Department of Speech-Language Pathology, University of Toronto, Toronto, Ontario M5G 1V7, Canada
| | - Elizabeth A Walker
- Department of Communication Sciences and Disorders, University of Iowa, Iowa City, Iowa 52242, USA
| |
Collapse
|
10
|
Nørgaard KM, Bray PJ. Comments on forward pressure and other reflectance-based quantities for delivering stimuli to the ear. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:909. [PMID: 36859130 DOI: 10.1121/10.0017119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 01/19/2023] [Indexed: 06/18/2023]
Abstract
The forward pressure has been proposed as an "optimal" reflectance-based quantity for delivering stimuli to the ear during evoked otoacoustic-emission measurements and audiometry. It is motivated by and avoids detrimental stimulus-level errors near standing-wave antiresonance frequencies when levels are adjusted in situ. While enjoying widespread popularity within research, the forward pressure possesses certain undesirable properties, some of which complicate its implementation into commercial otoacoustic-emission instruments conforming to existing international standards. These properties include its inability to approximate the total sound pressure anywhere in the ear canal and its discrepancy from the sound pressure at the tympanic membrane, which depends directly on the reflectance. This paper summarizes and comments on such properties of the forward pressure. Further, based on previous published data, alternative reflectance-based quantities that do not share these properties are investigated. A complex integrated pressure, with magnitude identical to the previously proposed scalar integrated pressure, is suggested as a suitable quantity for avoiding standing-wave errors when delivering stimuli to the ear. This complex integrated pressure approximates the magnitude and phase of the sound pressure at the tympanic membrane and can immediately be implemented into standardized commercial instruments to take advantage of improved stimulus-level accuracy and reproducibility in the clinic.
Collapse
Affiliation(s)
| | - Peter J Bray
- Interacoustics A/S, Audiometer Allé 1, Middelfart, DK-5500, Denmark
| |
Collapse
|
11
|
Nørgaard KM. A reciprocity method for validating acoustic ear-probe source calibrations. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:2652. [PMID: 36456301 DOI: 10.1121/10.0014959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Accepted: 10/08/2022] [Indexed: 06/17/2023]
Abstract
Measurements of wideband acoustic immittance (WAI) rely on the calibration of an ear probe to obtain its acoustic source parameters. The clinical use of WAI and instruments offering the functionality are steadily growing, however, no international standard exists to ensure a certain reliability of the hardware and methods underlying such measurements. This paper describes a reciprocity method that can evaluate the accuracy of and identify errors in ear-probe source calibrations. By placing the ear probes of two calibrated WAI instruments face-to-face at opposite ends of a short waveguide, the source parameters of each ear probe can be measured using the opposite calibrated ear probe. The calibrated and measured source parameters of each ear probe can then be compared directly, and the influence of possible calibration errors on WAI measurements may be approximated. In various exemplary ear-probe calibrations presented here, the reciprocity method accurately identifies errors that would otherwise remain undetected and result in measurement errors in real ears. The method is likely unsuitable for routine calibration of WAI instruments but may be considered for conformance testing as part of a potential future WAI standard.
Collapse
|
12
|
Boothalingam S, Easwar V, Bross A. External and middle ear influence on envelope following responses. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:2794. [PMID: 36456277 DOI: 10.1121/10.0015004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 10/11/2022] [Indexed: 06/17/2023]
Abstract
Considerable between-subject variability in envelope following response (EFR) amplitude limits its clinical translation. Based on a pattern of lower amplitude and larger variability in the low (<1.2 kHz) and high (>8 kHz), relative to mid (1-3 kHz) frequency carriers, we hypothesized that the between-subject variability in external and middle ear (EM) contribute to between-subject variability in EFR amplitude. It is predicted that equalizing the stimulus reaching the cochlea by accounting for EM differences using forward pressure level (FPL) calibration would at least partially improve response amplitude and reduce between-subject variability. In 21 young normal hearing adults, EFRs of four modulation rates (91, 96, 101, and 106 Hz) were measured concurrently from four frequency bands [low (0.091-1.2 kHz), mid (1-3 kHz), high (4-5.4 kHz), and very high (vHigh; 8-9.4 kHz)], respectively, with 12 harmonics each. The results indicate that FPL calibration in-ear and in a coupler leads to larger EFR amplitudes in the low and vHigh frequency bands relative to conventional coupler root-mean-square calibration. However, improvement in variability was modest with FPL calibration. This lack of a statistically significant improvement in variability suggests that the dominant source of variability in EFR amplitude may arise from cochlear and/or neural processing.
Collapse
Affiliation(s)
- Sriram Boothalingam
- Department of Communication Sciences and Disorders, Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Vijayalakshmi Easwar
- Department of Communication Sciences and Disorders, Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Abigail Bross
- Department of Communication Sciences and Disorders, Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| |
Collapse
|
13
|
Abdala C, Luo P, Shera CA. Characterizing the Relationship Between Reflection and Distortion Otoacoustic Emissions in Normal-Hearing Adults. J Assoc Res Otolaryngol 2022; 23:647-664. [PMID: 35804277 PMCID: PMC9613820 DOI: 10.1007/s10162-022-00857-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 06/24/2022] [Indexed: 11/28/2022] Open
Abstract
Otoacoustic emissions (OAEs) arise from one (or a combination) of two basic generation mechanisms in the cochlea: nonlinear distortion and linear reflection. As a result of having distinct generation processes, these two classes of emissions may provide non-redundant information about hair-cell integrity and show distinct sensitivities to cochlear pathology. Here, we characterize the relationship between reflection and distortion emissions in normal hearers across a broad frequency and stimulus-level space using novel analysis techniques. Furthermore, we illustrate the promise of this approach in a small group of individuals with mild-moderate hearing loss. A "joint-OAE profile" was created by measuring interleaved swept-tone stimulus-frequency OAEs (SFOAEs) and 2f1-f2 distortion-product OAEs (DPOAEs) in the same ears using well-considered parameters. OAE spectra and input/output functions were calculated across five octaves. Using our specific recording protocol and analysis scheme, SFOAEs in normal hearers had higher levels than did DPOAEs, with the most pronounced differences occurring at the highest stimulus levels. Also, SFOAE compression occurred at higher stimulus levels (than did DPOAE compression) and its growth in the compressed region was steeper. The diagnostic implications of these findings and the influence of the measurement protocol on both OAEs (and on their relationship) are discussed.
Collapse
Affiliation(s)
- Carolina Abdala
- Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, CA, 90033, USA.
| | - Ping Luo
- Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, CA, 90033, USA
| | - Christopher A Shera
- Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, CA, 90033, USA
- Department of Physics and Astronomy, University of Southern California, Los Angeles, CA, 90089, USA
| |
Collapse
|
14
|
Distortion Product Otoacoustic Emission Component Behavior as a Function of Primary Frequency Ratio and Primary Level. Ear Hear 2022; 43:1824-1835. [PMID: 35853351 PMCID: PMC9588520 DOI: 10.1097/aud.0000000000001251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVES Distortion product otoacoustic emissions (DPOAEs) are composed of distortion and reflection components. Much is known about the influence of the stimulus frequency ratio (f 2 /f 1 ) on the overall/composite DPOAE level. However, the influence of f 2 /f 1 on individual DPOAE components is not as well examined. The goals of this pilot study were to systematically evaluate the effects of f 2 /f 1 on DPOAE components in clinically normal-hearing young adult ears. To extend the limited reports in the literature, this examination was carried out over an extended frequency range using two stimulus-level combinations. DESIGN DPOAEs were recorded from seven normal-hearing, young adult ears for f 2 frequencies between 0.75 and 16 kHz over a range of f 2 /f 1 using two stimulus-level combinations. The distortion (DPOAE D ) and reflection (DPOAE R ) components were separated using an inverse fast Fourier transform algorithm. Optimal ratios for the composite DPOAE and DPOAE components were determined from smoothed versions of level versus ratio functions in each case. RESULTS The optimal ratio for the composite DPOAE level increased with stimulus level and decreased as a function of frequency above 1 kHz. The optimal ratios for the DPOAE components followed a similar trend, decreasing with increasing frequency. The optimal ratio for DPOAE D was generally higher than that for DPOAE R . The overall level for DPOAE D was greater than that of DPOAE R , both decreasing with increasing frequency. DPOAE R , but not DPOAE D , became unrecordable above the noise floor at the higher frequencies. CONCLUSIONS DPOAE components behave similarly but not identically as a function of f 2 /f 1 . The ear canal DPOAE is generally dominated by DPOAE D . The behavior of DPOAE D as a function of f 2 /f 1 is entirely consistent with known properties of cochlear mechanics. The behavior of DPOAE R is more variable across ears, perhaps reflective of the increased number of parameters that influence its final form. Attempting to use an f 2 /f 1 that would allow a greater bias of the ear canal DPOAE toward one component or the other does not appear to be practical.
Collapse
|
15
|
Nørgaard KM, Hajicek JJ. A systematic study on effects of calibration-waveguide geometry and least-squares formulation on ear-probe source calibrations. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:634. [PMID: 35105049 PMCID: PMC8807002 DOI: 10.1121/10.0009325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 12/31/2021] [Accepted: 12/31/2021] [Indexed: 06/14/2023]
Abstract
Measuring ear-canal absorbance and compensating for effects of the ear-canal acoustics on otoacoustic-emission measurements using an ear probe rely on accurately determining its acoustic source parameters. Using pressure measurements made in several rigid waveguides and models of their input impedances, a conventional calibration method estimates the ear-probe Thévenin-equivalent source parameters via a least-squares fit to an over-determined system of equations. Such a calibration procedure involves critical considerations on the geometry and number of utilized calibration waveguides. This paper studies the effects of calibration-waveguide geometry on achieving accurate ear-probe calibrations and measurements by systematically varying the lengths, length ratios, radii, and number of waveguides. For calibration-waveguide lengths in the range of 10-60 mm, accurate calibrations were generally obtained with absorbance measurement errors of approximately 0.02. Longer waveguides resulted in calibration errors, mainly due to coincident resonance frequencies among waveguides in the presence of mismatches between their assumed and actual geometries. The accuracy of calibrations was independent of the calibration-waveguide radius, except for an increased sensitivity of wider waveguides to noise. Finally, it is demonstrated how reformulating the over-determined system of equations to return the least-squares reflectance source parameters substantially reduces calibration and measurement errors.
Collapse
Affiliation(s)
| | - Joshua J Hajicek
- George G. Brown Laboratory, Department of Mechanical Engineering, University of Michigan, 2350 Hayward Street, Ann Arbor, Michigan 48109, USA
| |
Collapse
|
16
|
Hernández-Pérez H, Mikiel-Hunter J, McAlpine D, Dhar S, Boothalingam S, Monaghan JJM, McMahon CM. Understanding degraded speech leads to perceptual gating of a brainstem reflex in human listeners. PLoS Biol 2021; 19:e3001439. [PMID: 34669696 PMCID: PMC8559948 DOI: 10.1371/journal.pbio.3001439] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 11/01/2021] [Accepted: 10/07/2021] [Indexed: 11/19/2022] Open
Abstract
The ability to navigate "cocktail party" situations by focusing on sounds of interest over irrelevant, background sounds is often considered in terms of cortical mechanisms. However, subcortical circuits such as the pathway underlying the medial olivocochlear (MOC) reflex modulate the activity of the inner ear itself, supporting the extraction of salient features from auditory scene prior to any cortical processing. To understand the contribution of auditory subcortical nuclei and the cochlea in complex listening tasks, we made physiological recordings along the auditory pathway while listeners engaged in detecting non(sense) words in lists of words. Both naturally spoken and intrinsically noisy, vocoded speech-filtering that mimics processing by a cochlear implant (CI)-significantly activated the MOC reflex, but this was not the case for speech in background noise, which more engaged midbrain and cortical resources. A model of the initial stages of auditory processing reproduced specific effects of each form of speech degradation, providing a rationale for goal-directed gating of the MOC reflex based on enhancing the representation of the energy envelope of the acoustic waveform. Our data reveal the coexistence of 2 strategies in the auditory system that may facilitate speech understanding in situations where the signal is either intrinsically degraded or masked by extrinsic acoustic energy. Whereas intrinsically degraded streams recruit the MOC reflex to improve representation of speech cues peripherally, extrinsically masked streams rely more on higher auditory centres to denoise signals.
Collapse
Affiliation(s)
- Heivet Hernández-Pérez
- Department of Linguistics, The Australian Hearing Hub, Macquarie University, Sydney, Australia
| | - Jason Mikiel-Hunter
- Department of Linguistics, The Australian Hearing Hub, Macquarie University, Sydney, Australia
| | - David McAlpine
- Department of Linguistics, The Australian Hearing Hub, Macquarie University, Sydney, Australia
| | - Sumitrajit Dhar
- Department of Communication Sciences and Disorders, Northwestern University, Evanston, Illinois, United States of America
| | - Sriram Boothalingam
- University of Wisconsin-Madison, Madison, Wisconsin, United States of America
| | - Jessica J. M. Monaghan
- Department of Linguistics, The Australian Hearing Hub, Macquarie University, Sydney, Australia
- National Acoustic Laboratories, Sydney, Australia
| | - Catherine M. McMahon
- Department of Linguistics, The Australian Hearing Hub, Macquarie University, Sydney, Australia
| |
Collapse
|
17
|
Wideband Acoustic Immittance in Cochlear Implant Recipients: Reflectance and Stapedial Reflexes. Ear Hear 2021; 41:883-895. [PMID: 31688195 DOI: 10.1097/aud.0000000000000810] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES to characterize differences in wideband power reflectance for ears with and without cochlear implants (CIs), to describe electrically evoked stapedial reflex (eSR)-induced changes in reflectance, and to evaluate the benefit of a broadband probe for reflex threshold determination for CI recipients. It was hypothesized that reflectance patterns in ears with CIs would be consistent with increased middle ear stiffness and that reflex thresholds measured with a broadband probe would be lower compared with thresholds obtained with a single-frequency probe. DESIGN Eleven CI recipients participated in both wideband reflectance and eSR testing. Ipsilateral reflexes were measured with three probes: a broadband chirp (swept from 200 to 8000 Hz), a 226 Hz tone, and a 678 Hz tone. Wideband reflectance measures acquired from 28 adults without CIs and with normal middle ear function served as a normative data set for comparison. RESULTS Considering the group data, average reflectance was significantly greater for ears with CIs across 250 to 891 Hz and 4238 to 4490 Hz compared with the normative data set, although individual reflectance curves were variable. Some CI recipients also had low 226 Hz admittance, which contributed to the group finding, considering the control group had clinically normal 226 Hz admittance by design. Electrically evoked stapedial reflexes were measurable in nine of 14 ears (64.3%) and in 24 of 46 electrodes (52.5%) tested. Reflex-induced changes in reflectance patterns were unique to the participant/ear, but similar across activators (electrodes) within a given ear. In addition, reflectance values at or above 1000 Hz were affected most by activating the stapedial reflex, even in ears with clinically normal 226 Hz admittance. This is a higher-frequency range than has been reported for acoustically evoked reflex-induced reflectance changes and is consistent with increased middle ear stiffness at rest. Electrically evoked reflexes could be measured more often with the 678 Hz or the broadband probe compared with the 226 Hz probe tone. Although reflex thresholds were lower with the broadband probe compared with the 678 Hz probe in 16 of 24 conditions, this was not a statistically significant finding (Wilcoxon signed-rank test; p = 0.072). CONCLUSIONS The applications of wideband acoustic immittance measurements (reflectance and reflexes) should also be considered for ears with CIs. Further work is needed to describe changes across time in ears with CIs to more fully understand the reflectance pattern indicating increased middle ear stiffness and to optimize measuring eSRs with a broadband probe.
Collapse
|
18
|
Nørgaard KM, Allen JB, Neely ST. On causality and aural impulse responses synthesized using the inverse discrete Fourier transform. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:3524. [PMID: 34241097 DOI: 10.1121/10.0005048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 04/30/2021] [Indexed: 06/13/2023]
Abstract
Causality is a fundamental property of physical systems and dictates that a time impulse response characterizing any causal system must be one-sided. However, when synthesized using the inverse discrete Fourier transform (IDFT) of a corresponding band-limited numerical frequency transfer function, several papers have reported two-sided IDFT impulse responses of ear-canal reflectance and ear-probe source parameters. Judging from the literature on ear-canal reflectance, the significance and source of these seemingly non-physical negative-time components appear largely unclear. This paper summarizes and clarifies different sources of negative-time components through ideal and practical examples and illustrates the implications of constraining aural IDFT impulse responses to be one-sided. Two-sided IDFT impulse responses, derived from frequency-domain measurements of physical systems, normally occur due to the two-sided properties of the discrete Fourier transform. Still, reflectance IDFT impulse responses may serve a number of practical and diagnostic purposes.
Collapse
Affiliation(s)
| | - Jont B Allen
- Department of Electrical and Computer Engineering, University of Illinois, Urbana-Champaign, 306 North Wright Street, Champaign, Illinois 61820, USA
| | - Stephen T Neely
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| |
Collapse
|
19
|
Boothalingam S, Goodman SS. Click evoked middle ear muscle reflex: Spectral and temporal aspects. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:2628. [PMID: 33940882 DOI: 10.1121/10.0004217] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Accepted: 03/18/2021] [Indexed: 06/12/2023]
Abstract
This study describes a time series-based method of middle ear muscle reflex (MEMR) detection using bilateral clicks. Although many methods can detect changes in the otoacoustic emissions evoking stimulus to monitor the MEMR, they do not discriminate between true MEMR-mediated vs artifactual changes in the stimulus. We measured MEMR in 20 young clinically normal hearing individuals using 1-s-long click trains presented at six levels (65 to 95 dB peak-to-peak sound pressure level in 6 dB steps). Changes in the stimulus levels over the 1 s period were well-approximated by two-term exponential functions. The magnitude of ear canal pressure changes due to MEMR increased monotonically as a function of click level but non-monotonically with frequency when separated into 1/3 octave wide bands between 1 and 3.2 kHz. MEMR thresholds estimated using this method were lower than that obtained from a clinical tympanometer in ∼94% of the participants. A time series-based method, along with statistical tests, may provide additional confidence in detecting the MEMR. MEMR effects were smallest at 2 kHz, between 1 and 3.2 kHz, which may provide avenues for minimizing the MEMR influence while measuring other responses (e.g., the medial olivocochlear reflex).
Collapse
Affiliation(s)
- Sriram Boothalingam
- Department of Communication Sciences and Disorders, Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Shawn S Goodman
- Department of Communication Sciences and Disorders, University of Iowa, Iowa City, Iowa 52252, USA
| |
Collapse
|
20
|
Goodman SS, Boothalingam S, Lichtenhan JT. Medial olivocochlear reflex effects on amplitude growth functions of long- and short-latency components of click-evoked otoacoustic emissions in humans. J Neurophysiol 2021; 125:1938-1953. [PMID: 33625926 DOI: 10.1152/jn.00410.2020] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Functional outcomes of medial olivocochlear reflex (MOCR) activation, such as improved hearing in background noise and protection from noise damage, involve moderate to high sound levels. Previous noninvasive measurements of MOCR in humans focused primarily on otoacoustic emissions (OAEs) evoked at low sound levels. Interpreting MOCR effects on OAEs at higher levels is complicated by the possibility of the middle-ear muscle reflex and by components of OAEs arising from different locations along the length of the cochlear spiral. We overcame these issues by presenting click stimuli at a very slow rate and by time-frequency windowing the resulting click-evoked (CE)OAEs into short-latency (SL) and long-latency (LL) components. We characterized the effects of MOCR on CEOAE components using multiple measures to more comprehensively assess these effects throughout much of the dynamic range of hearing. These measures included CEOAE amplitude attenuation, equivalent input attenuation, phase, and slope of growth functions. Results show that MOCR effects are smaller on SL components than LL components, consistent with SL components being generated slightly basal of the characteristic frequency region. Amplitude attenuation measures showed the largest effects at the lowest stimulus levels, but slope change and equivalent input attenuation measures did not decrease at higher stimulus levels. These latter measures are less commonly reported and may provide insight into the variability in listening performance and noise susceptibility seen across individuals.NEW & NOTEWORTHY The auditory efferent system, operating at moderate to high sound levels, may improve hearing in background noise and provide protection from noise damage. We used otoacoustic emissions to measure these efferent effects across a wide range of sound levels and identified level-dependent and independent effects. Previous reports have focused on level-dependent measures. The level-independent effects identified here may provide new insights into the functional relevance of auditory efferent activity in humans.
Collapse
Affiliation(s)
- Shawn S Goodman
- Department of Communication Sciences and Disorders, University of Iowa, Iowa City, Iowa
| | - Sriram Boothalingam
- Department of Communication Sciences and Disorders, Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin
| | - Jeffery T Lichtenhan
- Department of Otolaryngology, Washington University School of Medicine in St. Louis, St. Louis, Missouri
| |
Collapse
|
21
|
Christensen AT, Shera CA, Abdala C. Extended low-frequency phase of the distortion-product otoacoustic emission in human newborns. JASA EXPRESS LETTERS 2021; 1:014404. [PMID: 33589887 PMCID: PMC7850017 DOI: 10.1121/10.0003192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Accepted: 10/22/2020] [Indexed: 06/12/2023]
Abstract
At constant f 2 / f 1 ratios, the phase of the nonlinear distortion component of the 2 f 1 - f 2 distortion-product otoacoustic emission (DPOAE) has a steep low-frequency segment and a flat high-frequency segment in adults and newborns. In adults, recent work found that a third segment characterizes the phase at even lower frequencies. The present study tests whether the same is true of the newborn DPOAE phase. Newborn and adult phase curves are generally similar. However, as previously reported, phase-gradient delays at mid frequencies (the region of steepest phase slope) are 50% longer in newborns.
Collapse
Affiliation(s)
- Anders T Christensen
- Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California 90033, USA
| | - Christopher A Shera
- Caruso Department of Otolaryngology and Department of Physics and Astronomy, University of Southern California, Los Angeles, California 90033, USA , ,
| | - Carolina Abdala
- Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California 90033, USA
| |
Collapse
|
22
|
Marcrum SC, Höfle E, Picou EM, Steffens T, Kummer P, Kwok P. A clinical comparison of DPOAE fine structure reduction methods. Int J Audiol 2020; 60:191-201. [PMID: 32985942 DOI: 10.1080/14992027.2020.1822552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVE To evaluate two real-time methods for reducing distortion product otoacoustic emission (DPOAE) fine structure in terms of DPOAE amplitude and fine structure depth. DESIGN A prospective, repeated-measures design was used to assess DPOAE characteristics in response to a conventional stimulation method (Conv.), as well as for methods implementing either a generic suppressor tone (Supp.) or frequency modulation of the f2 primary tone (FM). STUDY SAMPLE Eighty-three young adults (58 females) between the ages of 20 and 34 years with normal hearing completed testing for this study. RESULTS Use of the Conv. and FM methods resulted in consistently higher DPOAE levels relative to the Supp. method, with average advantages of 6 and 5 dB, respectively. For all methods, increased fine structure depth was observed for stimulation with lower level (25-45 dB SPL) and lower frequency (1000-3000 Hz) primary tones. Finally, use of the Supp. and FM methods resulted in significantly decreased fine structure depth relative to the Conv. method. CONCLUSION Through frequency modulation of the f2 primary tone, it was possible to reduce the depth of fine structure across a clinically meaningful range of stimulation levels and frequencies without concomitant reduction in DPOAE amplitude.
Collapse
Affiliation(s)
- Steven C Marcrum
- Department of Otolaryngology, University Hospital Regensburg, Regensburg, Germany
| | - Eva Höfle
- Department of Otolaryngology, University Hospital Regensburg, Regensburg, Germany
| | - Erin M Picou
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Thomas Steffens
- Department of Otolaryngology, University Hospital Regensburg, Regensburg, Germany
| | - Peter Kummer
- Section Phoniatrics and Pediatric Audiology, Department of Otolaryngology, University Hospital Regensburg, Regensburg, Germany
| | - Pingling Kwok
- Department of Otolaryngology, University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
23
|
Christensen AT, Abdala C, Shera CA. A cochlea with three parts? Evidence from otoacoustic emission phase in humans. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:1585. [PMID: 33003861 PMCID: PMC7789857 DOI: 10.1121/10.0001920] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 08/14/2020] [Accepted: 08/19/2020] [Indexed: 06/11/2023]
Abstract
The apical and basal regions of the cochlea appear functionally distinct. In humans, compelling evidence for an apical-basal transition derives from the phase of otoacoustic emissions (OAEs), whose frequency dependence differs at low and high frequencies. Although OAEs arising from the two major source mechanisms (distortion and reflection) both support the existence of an apical-basal transition-as identified via a prominent bend (or "break") in OAE phase slope-the two OAE types disagree about its precise location along the cochlea. Whereas distortion OAEs at frequency 2f1-f2 suggest that the apical-basal transition occurs near the 2.5 kHz place, reflection OAEs locate the transition closer to 1 kHz. To address this discrepancy, distortion and reflection OAEs were measured and analyzed in 20 young human adults from 0.25-8 kHz and at eight primary-frequency ratios f2/f1 in the range 1-1.5. Break frequencies and OAE phase-gradient delays were estimated by fitting segmented linear models to the unwrapped phase. When distortion- and reflection-OAE phase are considered as functions of ln f2-that is, as linear functions of the location of their putative site of generation within the cochlea-the analysis identifies not just two but three main cochlear segments, meeting at transition frequencies of approximately 0.9 and 2.6 kHz, whose locations are largely independent both of primary-frequency ratio and emission type. A simple model incorporating an abrupt transition from wave- to place-fixed behavior near the middle of the cochlea accounts for key features of distortion-OAE phase.
Collapse
Affiliation(s)
- Anders T Christensen
- Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California 90033, USA
| | - Carolina Abdala
- Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California 90033, USA
| | - Christopher A Shera
- Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California 90033, USA
| |
Collapse
|
24
|
Bhatt IS. Determinants of the Audiometric Notch at 4000 and 6000 Hz in Young Adults. J Am Acad Audiol 2020; 31:371-383. [DOI: 10.3766/jaaa.19030] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Abstract
Background Noise-induced hearing loss (NIHL) is often characterized by the presence of an audiometric notch at 3000-6000 Hz in a behavioral audiogram. The audiometric notch is widely used to investigate NIHL in children and young adults. However, the determinants of the audiometric notch in young adults largely remain unknown.
Purpose The study aimed to investigate the determinants of the audiometric notch in young adults.
Research Design A cross-sectional design was adopted for the study.
Study Sample A sample of 124 adults (38 males and 86 females) aged 18-35 years with normal otoscopic and tympanometric findings was recruited.
Data Collection and Analysis Hearing thresholds and real-ear sound pressure levels (RESPLs) were obtained with calibrated ER-3A (Etymotic Research, Elk Grove Village, IL) andTDH-50P receivers (Telephonics, Farmingdale, NY). Distortion-product otoacoustic emissions (DPOAEs) were used to evaluate the cochlear function. The external auditory canal (EAC) length was measured using the acoustical method. Noise exposure background (NEB) was estimated using the Noise Exposure Questionnaire. The notched audiograms were identified using: Phillips, Coles, and Niskar criteria.
Results The prevalence of notched audiograms was substantially higher for TDH-50P supra-aural receivers than for ER-3A insert receivers. RESPLs at 6000 and 8000 Hz were the major predictors of notched audiograms for TDH-50P receivers. These predictors explained around 45% of the variance in the notched audiograms. The notched audiograms obtained with TDH-50P receivers showed no association with NEB. Individuals with notched audiograms measured using TDH-50P did not show convincing evidence of cochlear dysfunction as assessed by DPOAEs. Individuals with notched audiograms obtained with TDH-50P receivers revealed an average of shorter EAC and a poorer hearing threshold at 6000 Hz.
Conclusions The calibration error in the RESPLs at 6000 and 8000 Hz that are likely to be influenced by the shorter EAC was the major determinant of the notched audiograms when the supra-aural transducers were used to measure hearing thresholds. Therefore, the supra-aural receivers should not be used to estimate the prevalence of NIHL in children and young adults when the less restrictive notch identification criteria are used to identify NIHL. Real-ear calibration techniques that are least influenced by the standing waves in the EAC should be preferred when investigating the prevalence of and risk factors for NIHL in young adults.
Collapse
Affiliation(s)
- Ishan Sunilkumar Bhatt
- Department of Communication Sciences & Disorders, Northern Arizona University, Flagstaff, AZ
| |
Collapse
|
25
|
Zelle D, Bader K, Dierkes L, Gummer AW, Dalhoff E. Derivation of input-output functions from distortion-product otoacoustic emission level maps. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:3169. [PMID: 32486784 DOI: 10.1121/10.0001142] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Accepted: 04/07/2020] [Indexed: 06/11/2023]
Abstract
Distortion-product otoacoustic emissions (DPOAEs) emerge from the cochlea when elicited with two tones of frequencies f1 and f2. DPOAEs mainly consist of two components, a nonlinear-distortion and a coherent-reflection component. Input-output (I/O) functions of DPOAE pressure at the cubic difference frequency, fDP=2f1-f2, enable the computation of estimated distortion-product thresholds (EDPTs), offering a noninvasive approach to estimate auditory thresholds. However, wave interference between the DPOAE components and suboptimal stimulus-level pairs reduces the accuracy of EDPTs. Here, the amplitude P of the nonlinear-distortion component is extracted from short-pulse DPOAE time signals. DPOAE level maps representing the growth behavior of P in L1,L2 space are recorded for 21 stimulus-level pairs and 14 frequencies with f2=1 to 14 kHz (f2/f1=1.2) from 20 ears. Reproducing DPOAE growth behavior using a least-squares fit approach enables the derivation of ridge-based I/O functions from model level maps. Objective evaluation criteria assess the fit results and provide EDPTs, which correlate significantly with auditory thresholds (p < 0.001). In conclusion, I/O functions derived from model level maps provide EDPTs with high precision but without the need of predefined optimal stimulus-level pairs.
Collapse
Affiliation(s)
- Dennis Zelle
- Section of Physiological Acoustics and Communication, Department of Otolaryngology, Eberhard-Karls-University Tübingen, Elfriede-Aulhorn-Straße 5, 72076 Tübingen, Germany
| | - Katharina Bader
- Department of Otolaryngology, Head and Neck Surgery, Eberhard-Karls-University Tübingen, Elfriede-Aulhorn- Straße 5, 72076 Tübingen, Germany
| | - Linda Dierkes
- Department of Otolaryngology, Head and Neck Surgery, Eberhard-Karls-University Tübingen, Elfriede-Aulhorn- Straße 5, 72076 Tübingen, Germany
| | - Anthony W Gummer
- Section of Physiological Acoustics and Communication, Department of Otolaryngology, Eberhard-Karls-University Tübingen, Elfriede-Aulhorn-Straße 5, 72076 Tübingen, Germany
| | - Ernst Dalhoff
- Section of Physiological Acoustics and Communication, Department of Otolaryngology, Eberhard-Karls-University Tübingen, Elfriede-Aulhorn-Straße 5, 72076 Tübingen, Germany
| |
Collapse
|
26
|
Effects of Forward- and Emitted-Pressure Calibrations on the Variability of Otoacoustic Emission Measurements Across Repeated Probe Fits. Ear Hear 2020; 40:1345-1358. [PMID: 30882535 DOI: 10.1097/aud.0000000000000714] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The stimuli used to evoke otoacoustic emissions (OAEs) are typically calibrated based on the total SPL measured at the probe microphone. However, due to the acoustics of the ear-canal space (i.e., standing-wave interference), this method can underestimate the stimulus pressure reaching the tympanic membrane at certain frequencies. To mitigate this effect, stimulus calibrations based on forward pressure level (FPL) can be applied. Furthermore, the influence of ear-canal acoustics on measured OAE levels can be compensated by expressing them in emitted pressure level (EPL). To date, studies have used artificial shallow versus deep probe fits to assess the effects of calibration method on changes in probe insertion. In an attempt to better simulate a clinical setting, the combined effects of FPL calibration of stimulus level and EPL compensation of OAE level on response variability during routine (noncontrived) probe fittings were examined. DESIGN The distortion component of the distortion-product OAE (DPOAE) and the stimulus-frequency OAE (SFOAE) were recorded at low and moderate stimulus levels in 20 normal-hearing young-adult subjects across a five-octave range. In each subject, three different calibration approaches were compared: (1) the conventional SPL-based stimulus calibration with OAE levels expressed in SPL; (2) FPL stimulus calibration with OAEs expressed in SPL; and (3) FPL stimulus calibration with OAEs expressed in EPL. Test and retest measurements were obtained during the same session and, in a subset of subjects, several months after the initial test. The effects of these different procedures on the inter- and intra-subject variability of OAE levels were assessed across frequency and level. RESULTS There were no significant differences in the inter-subject variability of OAE levels across the three calibration approaches. However, there was a significant effect on OAE intra-subject variability. The FPL/EPL approach resulted in the overall lowest test-rest differences in DPOAE level for frequencies above 4 kHz, where standing-wave interference is strongest. The benefit was modest, ranging on average from 0.5 to 2 dB and was strongest at the lower stimulus level. SFOAE level variability did not show significant differences among the three procedures, perhaps due to insufficient signal-to-noise ratio and nonoptimized stimulus levels. Correlations were found between the short-term replicability of DPOAEs and the benefit derived from the FPL/EPL procedure: the more variable the DPOAE, the stronger the benefit conferred by the advanced calibration methods. CONCLUSIONS Stimulus and response calibration procedures designed to mitigate the effects of standing-wave interference on both the stimulus and the OAE enhance the repeatability of OAE measurements and reduce their dependence on probe position, even when probe shifts are small. Modest but significant improvements in short-term test-retest repeatability were observed in the mid- to high-frequency region when using combined FPL/EPL procedures. The authors posit that the benefit will be greater in a more heterogeneous group of subjects and when different testers participate in the fitting and refitting of subjects, which is a common practice in the audiology clinic. The impact of calibration approach on OAE inter-subject variability was not significant, possibly due to a homogeneous subject population and because factors other than probe position are at play.
Collapse
|
27
|
Nørgaard KM, Fernandez-Grande E, Schmuck C, Laugesen S. Reproducing ear-canal reflectance using two measurement techniques in adult ears. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:2334. [PMID: 32359297 DOI: 10.1121/10.0001094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 03/27/2020] [Indexed: 06/11/2023]
Abstract
Clinical diagnostic applications of ear-canal reflectance have been researched extensively in the literature, however, the measurement uncertainty associated with the conventional measurement technique using an insert ear probe is unknown in human ear canals. Ear-canal reflectance measured using an ear probe is affected by multiple sources of error, including incorrect estimates of the ear-canal cross-sectional area and oblique ear-probe insertions. In this paper, ear-canal reflectance measurements are reproduced in an occluded-ear simulator and in 54 adult ear canals using two different measurement techniques: a conventional ear probe and a two-microphone probe that enables the separation of reverse- and forward-propagating plane waves. The two-microphone probe is inserted directly into test subjects' ear canals, and the two-microphone method is distinguished by not requiring the ear-canal cross-sectional area to calculate the ear-canal reflectance. The results show a reasonable agreement between the two measurement techniques. The paper further examines the influence of oblique ear-probe insertions and the compensation for such oblique insertions, which results in an improved agreement between the two measurement techniques.
Collapse
Affiliation(s)
- Kren Monrad Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Efren Fernandez-Grande
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | | | - Søren Laugesen
- Interacoustics Research Unit, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| |
Collapse
|
28
|
Abstract
OBJECTIVES Cochlear reflectance (CR) is the cochlear contribution to ear-canal reflectance. CR is a type of otoacoustic emission (OAE) that is calculated as a transfer function between forward pressure and reflected pressure. The purpose of this study was to compare wideband CR to distortion-product (DP) OAEs in two ways: (1) in a clinical-screening paradigm where the task is to determine whether an ear is normal or has hearing loss and (2) in the prediction of audiometric thresholds. The goal of the study was to assess the clinical utility of CR. DESIGN Data were collected from 32 normal-hearing and 124 hearing-impaired participants. A wideband noise stimulus presented at 3 stimulus levels (30, 40, 50 dB sound pressure level) was used to elicit the CR. DPOAEs were elicited using primary tones spanning a wide frequency range (1 to 16 kHz). Predictions of auditory status (i.e., hearing-threshold category) and predictions of audiometric threshold were based on regression analysis. Test performance (identification of normal versus impaired hearing) was evaluated using clinical decision theory. RESULTS When regressions were based only on physiological measurements near the audiometric frequency, the accuracy of CR predictions of auditory status and audiometric threshold was less than reported in previous studies using DPOAE measurements. CR predictions were improved when regressions were based on measurements obtained at many frequencies. CR predictions were further improved when regressions were performed on males and females separately. CONCLUSIONS Compared with CR measurements, DPOAE measurements have the advantages in a screening paradigm of better test performance and shorter test time. The full potential of CR measurements to predict audiometric thresholds may require further improvements in signal-processing methods to increase its signal to noise ratio. CR measurements have theoretical significance in revealing the number of cycles of delay at each frequency that is most sensitive to hearing loss.
Collapse
|
29
|
Merchant GR, Siegel JH, Neely ST, Rosowski JJ, Nakajima HH. Effect of Middle-Ear Pathology on High-Frequency Ear Canal Reflectance Measurements in the Frequency and Time Domains. J Assoc Res Otolaryngol 2019; 20:529-552. [PMID: 31673928 PMCID: PMC6889121 DOI: 10.1007/s10162-019-00735-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Accepted: 08/20/2019] [Indexed: 10/25/2022] Open
Abstract
The effects of middle-ear pathology on wideband acoustic immittance and reflectance at frequencies above 6-8 kHz have not been documented, nor has the effect of such pathologies on the time-domain reflectance. We describe an approach that utilizes sound frequencies as high as 20 kHz and quantifies reflectance in both the frequency and time domains. Experiments were performed with fresh normal human temporal bones before and after simulating various middle-ear pathologies, including malleus fixation, stapes fixation, and disarticulation. In addition to experimental data, computational modeling was used to obtain fitted parameter values of middle-ear elements that vary systematically due to the simulated pathologies and thus may have diagnostic implications. Our results demonstrate that the time-domain reflectance, which requires acoustic measurements at high frequencies, varies with middle-ear condition. Furthermore, the extended bandwidth frequency-domain reflectance data was used to estimate parameters in a simple model of the ear canal and middle ear that separates three major conductive pathologies from each other and from the normal state.
Collapse
Affiliation(s)
- Gabrielle R. Merchant
- Speech and Hearing Bioscience and Technology, Harvard Division of Medical Sciences (formerly the Harvard-MIT Division of Health Sciences and Technology), Cambridge, MA USA
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA USA
- Boys Town National Research Hospital, Omaha, NE USA
| | | | | | - John J. Rosowski
- Speech and Hearing Bioscience and Technology, Harvard Division of Medical Sciences (formerly the Harvard-MIT Division of Health Sciences and Technology), Cambridge, MA USA
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA USA
- Department of Otology and Laryngology, Harvard Medical School, Boston, MA USA
| | - Hideko H. Nakajima
- Speech and Hearing Bioscience and Technology, Harvard Division of Medical Sciences (formerly the Harvard-MIT Division of Health Sciences and Technology), Cambridge, MA USA
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA USA
- Department of Otology and Laryngology, Harvard Medical School, Boston, MA USA
| |
Collapse
|
30
|
Christensen AT, Abdala C, Shera CA. Variable-rate frequency sweeps and their application to the measurement of otoacoustic emissions. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:3457. [PMID: 31795700 PMCID: PMC6872461 DOI: 10.1121/1.5134058] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 10/18/2019] [Accepted: 10/28/2019] [Indexed: 06/10/2023]
Abstract
Swept tones allow the efficient measurement of otoacoustic emissions (OAEs) with fine frequency resolution. Although previous studies have explored the influence of different sweep parameters on the measured OAE, none have directly considered their effects on the measurement noise floor. The present study demonstrates that parameters such as sweep type (e.g., linear or logarithmic), sweep rate, and analysis bandwidth affect the measurement noise and can be manipulated to control the noise floor in individual subjects. Although responses to discrete-tone stimuli can be averaged until the uncertainty of the measurement meets a specified criterion at each frequency, linear or logarithmic sweeps offer no such flexibility. However, measurements of the power spectral density of the ambient noise can be used to construct variable-rate sweeps that yield a prescribed (e.g., constant) noise floor across frequency; in effect, they implement a form of frequency-dependent averaging. The use of noise-compensating frequency sweeps is illustrated by the measurement of distortion-product OAEs at low frequencies, where the ear-canal noise is known to vary significantly.
Collapse
Affiliation(s)
- Anders T Christensen
- Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California 90033, USA
| | - Carolina Abdala
- Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California 90033, USA
| | - Christopher A Shera
- Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California 90033, USA
| |
Collapse
|
31
|
Keppler H, Lampo E, Degeest S, Botteldooren D, Vinck B, Bockstael A. Analysis of probe fitting stimulus properties on transient evoked otoacoustic emissions. Int J Audiol 2019; 59:45-53. [PMID: 31453735 DOI: 10.1080/14992027.2019.1656347] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Objective: The objectives of the current study are first, to evaluate the subjective evaluation of probe fitting stimulus properties, and second, to analyse the effects of different probe fittings on transient evoked otoacoustic emission (TEOAE) response and noise amplitudes in subjects.Design: The Q methodology was used to sort 48 probe fittings differing in stimulus properties in seven categories from totally unacceptable to certainly acceptable. Further, TEOAE response and noise amplitudes were measured in one baseline condition with optimal probe fitting and eight experimental conditions with less than optimal probe fittings.Study sample: The probe fittings were ranked by 18 participants, while the repeated measures design was performed in 34 ear.Results: First, it was found that only 19.61% of all distributions of the probe fittings by the participants had a mutual correlation of at least 70.00%. Almost 60% of the variance of distributions was explained by 83.33% of the participants, although most probe fittings significantly differed from other fittings based on spectral broadness. Second, significant differences in TEOAE response and especially noise amplitudes between conditions were found. Further, TEOAE response and noise amplitudes between the baseline and experimental conditions were significantly different depending on ringing and spectral flatness of the stimulus.Conclusion: A substantial amount of subjectivity during TEOAE measurements is involved with regard to the evaluation of probe fitting stimulus properties. TEOAE response but especially noise amplitudes are influenced by varying stimulus parameters which stresses the importance of inspecting these parameters prior to or during EOAE measurements. Although more research is needed, some guidelines regarding these parameters are given which could improve the accuracy of TEOAEs in practice.
Collapse
Affiliation(s)
- Hannah Keppler
- Department of Rehabilitation Sciences, Ghent University, Ghent, Belgium.,Department of Otorhinolaryngology, Ghent University Hospital, Ghent, Belgium
| | | | - Sofie Degeest
- Department of Rehabilitation Sciences, Ghent University, Ghent, Belgium
| | - Dick Botteldooren
- Department of Information Technology, Ghent University, WAVES Group, Ghent, Belgium
| | - Bart Vinck
- Department of Rehabilitation Sciences, Ghent University, Ghent, Belgium
| | - Annelies Bockstael
- Department of Information Technology, Ghent University, WAVES Group, Ghent, Belgium
| |
Collapse
|
32
|
Abstract
OBJECTIVES This study aims to determine the impact of controlling cochlear-source mechanism on the accuracy with which auditory status is identified using otoacoustic emissions (OAEs) in two groups of subjects with normal hearing (NH) and subjects with mild to moderate hearing loss. DESIGN Data were collected from 212 subjects with NH and with mild to moderate hearing loss who fell into two categories based on a distortion product OAE (DPOAE) screening protocol: the uncertain-identification group (where errors were likely) and the certain-identification group (where errors were unlikely). DPOAE fine-structure patterns were recorded at intervals surrounding f2 = 1, 2 and 4 kHz (f2/f1 ratio = 1.22), with L2 = 35, 45, and 55 dB SPL (L1/L2 ratio = 10 dB). The discrete cosine transform was used to smooth fine structure, limiting the source contribution to the distortion source only. Reflection-source OAEs were also recorded using amplitude-modulated stimulus frequency OAEs (AM-SFOAE). Area under the relative operating characteristic (AROC) curve was used to quantify test accuracy when the source contribution was controlled versus the condition where both sources contribute. Additionally, failure rate, fixed at 5% for NH ears, as a function of behavioral-threshold category was evaluated. RESULTS When data for the entire subject group were examined, reducing the reflection-source contribution to the DPOAE did not result in better test performance than the best control condition at any frequency tested. When the subjects with NH were restricted to those with confirmed fine structure, AROC analyses indicated that reducing the reflection-source contribution resulted in several small increases in the accuracy (2%-5%) with which auditory status was identified relative to the best control condition. This improvement was observed for the lowest stimulus levels (i.e., L2 = 35 or 45 dB SPL). In this subset of subjects, distortion-source DPOAEs resulted in more accurate identification of mild hearing loss for a fixed false-positive rate of 5% in NH ears at lower L2's, conditions with poor accuracy in the larger group of subjects. The impact of controlling the source contribution on the identification of moderate losses was less clear in the reduced subject group, with some conditions where the distortion-source DPOAE was more accurate than the control condition and other conditions where there was no change. There was no evidence that reflection-source AM-SFOAEs more accurately identified ears with hearing loss when compared to any of the DPOAE conditions in either the large or reduced group of subjects. CONCLUSION While improvements in test accuracy were observed for some subjects and some conditions (e.g., mild hearing losses and low stimulus levels in the reduced subset of subjects), these results suggest that restricting cochlear source contribution by "smoothing" DPOAE fine structure is not expected to improve DPOAE test accuracy in a general population of subjects. Likewise, recording reflection-source OAEs using the AM-SFOAE technique would not be expected to more accurately identify hearing status compared to mixed- or single-source DPOAEs.
Collapse
|
33
|
Emerging Distortion Product Otoacoustic Emission Techniques to Identify Preclinical Warning Signs of Basal Cochlear Dysfunction Due to Ototoxicity. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9153132] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Hundreds of medications commonly prescribed for anticancer treatments and some infections are known to cause hearing damage, referred to as ototoxicity. Preventing or minimizing ototoxicity is critical in order to preserve quality of life for patients receiving treatment and to reduce the societal burden of hearing loss. Current clinical evaluations are restricted to a limited frequency range (≤8 kHz); however, this approach does not permit the earliest detection of ototoxicity, most likely to be observed at the highest frequencies (9–20 kHz). Distortion product otoacoustic emissions (DPOAEs) offer a noninvasive, objective approach to monitor cochlear health in those unable to respond via conventional methods. The current report analyzes different DPOAE paradigms used in patients undergoing chemotherapy treatments with various platinum derivatives. Individualized serial monitoring protocols were completed at the highest frequencies with measurable DPOAEs. This allowed the exploration of potential clinical translation opportunities for further quantification of the earliest signs of underlying cochlear damage, which may go undetected with conventional methods. Clinical practice has the potential to be enhanced by emerging DPOAE applications, including targeted monitoring protocols and high-frequency stimuli to assess cochlear function, especially at the highest frequencies, and advanced calibration techniques to ensure the stability of serial measurements.
Collapse
|
34
|
Nørgaard KR, Charaziak KK, Shera CA. On the calculation of reflectance in non-uniform ear canals. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:1464. [PMID: 31472574 PMCID: PMC6713557 DOI: 10.1121/1.5124000] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 08/02/2019] [Accepted: 08/08/2019] [Indexed: 05/29/2023]
Abstract
Ear-canal reflectance is useful for quantifying the conductive status of the middle ear because it can be measured non-invasively at a distance from the tympanic membrane. Deriving the ear-canal reflectance requires decomposing the total acoustic pressure into its forward- and reverse-propagating components. This decomposition is conveniently achieved using formulas that involve the input and characteristic impedances of the ear canal. The characteristic impedance is defined as the ratio of sound pressure to volume flow of a propagating wave and, for uniform waveguides, the plane-wave characteristic impedance is a real-valued constant. However, in non-uniform waveguides, the characteristic impedances are complex-valued quantities, depend on the direction of propagation, and more accurately characterize a propagating wave in a non-uniform ear canal. In this paper, relevant properties of the plane-wave and spherical-wave characteristic impedances are reviewed. In addition, the utility of the plane-wave and spherical-wave reflectances in representing the reflection occurring due to the middle ear, calibrating stimulus levels, and characterizing the emitted pressure in simulated non-uniform ear canals is investigated and compared.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Karolina K Charaziak
- Caruso Department of Otolaryngology, University of Southern California, 1640 Marengo Street, Los Angeles, California 90033, USA
| | - Christopher A Shera
- Caruso Department of Otolaryngology, University of Southern California, 1640 Marengo Street, Los Angeles, California 90033, USA
| |
Collapse
|
35
|
Beim JA, Oxenham AJ, Wojtczak M. No effects of attention or visual perceptual load on cochlear function, as measured with stimulus-frequency otoacoustic emissions. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:1475. [PMID: 31472524 PMCID: PMC6715442 DOI: 10.1121/1.5123391] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 08/02/2019] [Accepted: 08/05/2019] [Indexed: 06/10/2023]
Abstract
The effects of selectively attending to a target stimulus in a background containing distractors can be observed in cortical representations of sound as an attenuation of the representation of distractor stimuli. The locus in the auditory system at which attentional modulations first arise is unknown, but anatomical evidence suggests that cortically driven modulation of neural activity could extend as peripherally as the cochlea itself. Previous studies of selective attention have used otoacoustic emissions to probe cochlear function under varying conditions of attention with mixed results. In the current study, two experiments combined visual and auditory tasks to maximize sustained attention, perceptual load, and cochlear dynamic range in an attempt to improve the likelihood of observing selective attention effects on cochlear responses. Across a total of 45 listeners in the two experiments, no systematic effects of attention or perceptual load were observed on stimulus-frequency otoacoustic emissions. The results revealed significant between-subject variability in the otoacoustic-emission measure of cochlear function that does not depend on listener performance in the behavioral tasks and is not related to movement-generated noise. The findings suggest that attentional modulation of auditory information in humans arises at stages of processing beyond the cochlea.
Collapse
Affiliation(s)
- Jordan A Beim
- Department of Psychology, University of Minnesota, 75 East River Parkway, Minneapolis, Minnesota 55455, USA
| | - Andrew J Oxenham
- Department of Psychology, University of Minnesota, 75 East River Parkway, Minneapolis, Minnesota 55455, USA
| | - Magdalena Wojtczak
- Department of Psychology, University of Minnesota, 75 East River Parkway, Minneapolis, Minnesota 55455, USA
| |
Collapse
|
36
|
Nørgaard KR, Charaziak KK, Shera CA. A comparison of ear-canal-reflectance measurement methods in an ear simulator. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:1350. [PMID: 31472530 PMCID: PMC6707811 DOI: 10.1121/1.5123379] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 08/02/2019] [Accepted: 08/03/2019] [Indexed: 05/30/2023]
Abstract
Ear-canal reflectance has been researched extensively for diagnosing conductive hearing disorders and compensating for the ear-canal acoustics in non-invasive measurements of the auditory system. Little emphasis, however, has been placed on assessing measurement accuracy and variability. In this paper, a number of ear-canal-reflectance measurement methods reported in the literature are utilized and compared. Measurement variation seems to arise chiefly from three factors: the residual ear-canal length, the ear-probe insertion angle, and the measurement frequency bandwidth. Calculation of the ear-canal reflectance from the measured ear-canal impedance requires estimating the ear-canal characteristic impedance in situ. The variability in ear-canal estimated characteristic impedance and reflectance due to these principal factors is assessed in an idealized controlled setup using a uniform occluded-ear simulator. In addition, the influence of this measurement variability on reflectance-based methods for calibrating stimulus levels is evaluated and, by operating the condenser microphone of the occluded-ear simulator as an electro-static speaker, the variability in estimating the emitted pressure from the ear is determined. The various measurement methods differ widely in their robustness to variations in the three principal factors influencing the accuracy and variability of ear-canal reflectance.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Karolina K Charaziak
- Caruso Department of Otolaryngology, University of Southern California, 1640 Marengo Street, Los Angeles, California 90033, USA
| | - Christopher A Shera
- Caruso Department of Otolaryngology, University of Southern California, 1640 Marengo Street, Los Angeles, California 90033, USA
| |
Collapse
|
37
|
Nørgaard KR, Fernandez-Grande E, Laugesen S. Compensating for oblique ear-probe insertions in ear-canal reflectance measurements. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:3499. [PMID: 31255109 DOI: 10.1121/1.5111340] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Accepted: 05/22/2019] [Indexed: 06/09/2023]
Abstract
Measurements of the ear-canal reflectance using an ear probe require estimating the characteristic impedance of the ear canal in situ. However, an oblique insertion of the ear probe into a uniform waveguide prevents accurately estimating its characteristic impedance using existing time-domain methods. This is caused by the non-uniformity immediately in front of the ear probe when inserted at an oblique angle, resembling a short horn loading, and introduces errors into the ear-canal reflectance. This paper gives an overview of the influence of oblique ear-probe insertions and shows how they can be detected and quantified by estimating the characteristic impedance using multiple truncation frequencies, i.e., limiting the utilized frequency range. Additionally, a method is proposed to compensate for the effects on reflectance of an oblique ear-probe insertion into a uniform waveguide. The incident impedance of the horn loading is estimated, i.e., were the uniform waveguide anechoic, which replaces the characteristic impedance when calculating reflectance. The method can compensate for an oblique ear-probe insertion into a uniform occluded-ear simulator and decrease the dependency of reflectance on insertion depth in an ear canal. However, more research is required to further assess the method in ear canals.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Efren Fernandez-Grande
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Søren Laugesen
- Interacoustics Research Unit, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| |
Collapse
|
38
|
Exploring the Role of Medial Olivocochlear Efferents on the Detection of Amplitude Modulation for Tones Presented in Noise. J Assoc Res Otolaryngol 2019; 20:395-413. [PMID: 31140010 PMCID: PMC6646499 DOI: 10.1007/s10162-019-00722-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Accepted: 04/15/2019] [Indexed: 10/26/2022] Open
Abstract
The medial olivocochlear reflex has been hypothesized to improve the detection and discrimination of dynamic signals in noisy backgrounds. This hypothesis was tested here by comparing behavioral outcomes with otoacoustic emissions. The effects of a precursor on amplitude-modulation (AM) detection were measured for a 1- and 6-kHz carrier at levels of 40, 60, and 80 dB SPL in a two-octave-wide noise masker with a level designed to produce poor, but above-chance, performance. Three types of precursor were used: a two-octave noise band, an inharmonic complex tone, and a pure tone. Precursors had the same overall level as the simultaneous noise masker that immediately followed the precursor. The noise precursor produced a large improvement in AM detection for both carrier frequencies and at all three levels. The complex tone produced a similarly large improvement in AM detection at the highest level but had a smaller effect for the two lower carrier levels. The tonal precursor did not significantly affect AM detection in noise. Comparisons of behavioral thresholds and medial olivocochlear efferent effects on stimulus frequency otoacoustic emissions measured with similar stimuli did not support the hypothesis that efferent-based reduction of cochlear responses contributes to the precursor effects on AM detection.
Collapse
|
39
|
Ridley CL, Kopun JG, Neely ST, Gorga MP, Rasetshwane DM. Using Thresholds in Noise to Identify Hidden Hearing Loss in Humans. Ear Hear 2019; 39:829-844. [PMID: 29337760 PMCID: PMC6046280 DOI: 10.1097/aud.0000000000000543] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Recent animal studies suggest that noise-induced synaptopathy may underlie a phenomenon that has been labeled hidden hearing loss (HHL). Noise exposure preferentially damages low spontaneous-rate auditory nerve fibers, which are involved in the processing of moderate- to high-level sounds and are more resistant to masking by background noise. Therefore, the effect of synaptopathy may be more evident in suprathreshold measures of auditory function, especially in the presence of background noise. The purpose of this study was to develop a statistical model for estimating HHL in humans using thresholds in noise as the outcome variable and measures that reflect the integrity of sites along the auditory pathway as explanatory variables. Our working hypothesis is that HHL is evident in the portion of the variance observed in thresholds in noise that is not dependent on thresholds in quiet, because this residual variance retains statistical dependence on other measures of suprathreshold function. DESIGN Study participants included 13 adults with normal hearing (≤15 dB HL) and 20 adults with normal hearing at 1 kHz and sensorineural hearing loss at 4 kHz (>15 dB HL). Thresholds in noise were measured, and the residual of the correlation between thresholds in noise and thresholds in quiet, which we refer to as thresholds-in-noise residual, was used as the outcome measure for the model. Explanatory measures were as follows: (1) auditory brainstem response (ABR) waves I and V amplitudes; (2) electrocochleographic action potential and summating potential amplitudes; (3) distortion product otoacoustic emissions level; and (4) categorical loudness scaling. All measurements were made at two frequencies (1 and 4 kHz). ABR and electrocochleographic measurements were made at 80 and 100 dB peak equivalent sound pressure level, while wider ranges of levels were tested during distortion product otoacoustic emission and categorical loudness scaling measurements. A model relating the thresholds-in-noise residual and the explanatory measures was created using multiple linear regression analysis. RESULTS Predictions of thresholds-in-noise residual using the model accounted for 61% (p < 0.01) and 48% (p < 0.01) of the variance in the measured thresholds-in-noise residual at 1 and 4 kHz, respectively. CONCLUSIONS Measures of thresholds in noise, the summating potential to action potential ratio, and ABR waves I and V amplitudes may be useful for the prediction of HHL in humans. With further development, our approach of quantifying HHL by the variance that remains in suprathreshold measures of auditory function after removing the variance due to thresholds in quiet, together with our statistical modeling, may provide a quantifiable and verifiable estimate of HHL in humans with normal hearing and with hearing loss. The current results are consistent with the view that inner hair cell and auditory nerve pathology may underlie suprathreshold auditory performance.
Collapse
Affiliation(s)
- Courtney L. Ridley
- Center for Hearing Research, Boys Town National Research Hospital, 555 North 30 St, Omaha, Nebraska 68131, USA
- Department of Speech, Language, and Hearing Sciences, University of Florida, 1225 Center Drive, Gainesville, FL 32610, USA
| | - Judy G. Kopun
- Center for Hearing Research, Boys Town National Research Hospital, 555 North 30 St, Omaha, Nebraska 68131, USA
| | - Stephen T. Neely
- Center for Hearing Research, Boys Town National Research Hospital, 555 North 30 St, Omaha, Nebraska 68131, USA
| | - Michael P. Gorga
- Center for Hearing Research, Boys Town National Research Hospital, 555 North 30 St, Omaha, Nebraska 68131, USA
| | - Daniel M. Rasetshwane
- Center for Hearing Research, Boys Town National Research Hospital, 555 North 30 St, Omaha, Nebraska 68131, USA
| |
Collapse
|
40
|
Bharadwaj HM, Mai AR, Simpson JM, Choi I, Heinz MG, Shinn-Cunningham BG. Non-Invasive Assays of Cochlear Synaptopathy - Candidates and Considerations. Neuroscience 2019; 407:53-66. [PMID: 30853540 DOI: 10.1016/j.neuroscience.2019.02.031] [Citation(s) in RCA: 73] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2018] [Revised: 02/21/2019] [Accepted: 02/25/2019] [Indexed: 12/31/2022]
Abstract
Studies in multiple species, including in post-mortem human tissue, have shown that normal aging and/or acoustic overexposure can lead to a significant loss of afferent synapses innervating the cochlea. Hypothetically, this cochlear synaptopathy can lead to perceptual deficits in challenging environments and can contribute to central neural effects such as tinnitus. However, because cochlear synaptopathy can occur without any measurable changes in audiometric thresholds, synaptopathy can remain hidden from standard clinical diagnostics. To understand the perceptual sequelae of synaptopathy and to evaluate the efficacy of emerging therapies, sensitive and specific non-invasive measures at the individual patient level need to be established. Pioneering experiments in specific mice strains have helped identify many candidate assays. These include auditory brainstem responses, the middle-ear muscle reflex, envelope-following responses, and extended high-frequency audiograms. Unfortunately, because these non-invasive measures can be also affected by extraneous factors other than synaptopathy, their application and interpretation in humans is not straightforward. Here, we systematically examine six extraneous factors through a series of interrelated human experiments aimed at understanding their effects. Using strategies that may help mitigate the effects of such extraneous factors, we then show that these suprathreshold physiological assays exhibit across-individual correlations with each other indicative of contributions from a common physiological source consistent with cochlear synaptopathy. Finally, we discuss the application of these assays to two key outstanding questions, and discuss some barriers that still remain. This article is part of a Special Issue entitled: Hearing Loss, Tinnitus, Hyperacusis, Central Gain.
Collapse
Affiliation(s)
- Hari M Bharadwaj
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN; Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN.
| | - Alexandra R Mai
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN
| | - Jennifer M Simpson
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN
| | - Inyong Choi
- Department of Communication Sciences and Disorders, University of Iowa, Iowa City, IA
| | - Michael G Heinz
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN; Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN
| | | |
Collapse
|
41
|
Ravicz ME, Cheng JT, Rosowski JJ. Sound pressure distribution within human ear canals: II. Reverse mechanical stimulation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:1569. [PMID: 31067954 PMCID: PMC6435373 DOI: 10.1121/1.5094776] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 03/01/2019] [Accepted: 03/04/2019] [Indexed: 06/09/2023]
Abstract
This work is part of a study of the interactions of ear canal (EC) sound with tympanic membrane (TM) surface displacements. In human temporal bones, the ossicles were stimulated mechanically "in reverse" to mimic otoacoustic emissions (OAEs), and the sound field within the ear canal was sampled with 0.5-2 mm spacing near the TM surface and at more distal locations within the EC, including along the longitudinal EC axis. Sound fields were measured with the EC open or occluded. The reverse-driven sound field near the TM had larger and more irregular spatial variations below 10 kHz than with forward sound stimulation, consistent with a significant contribution of nonuniform sound modes. These variations generally did not propagate more than ∼4 mm laterally from the TM. Longitudinal sound field variations with the EC open or blocked were consistent with standing-wave patterns in tubes with open or closed ends. Relative contributions of the nonuniform components to the total sound pressure near the TM were largest at EC natural frequencies where the longitudinal component was small. Transverse variations in EC sound pressure can be reduced by reducing longitudinal EC sound pressure variations, e.g., via reducing reflections from occluding earplugs.
Collapse
Affiliation(s)
- Michael E Ravicz
- Eaton-Peabody Laboratory, Massachusetts Eye & Ear, 243 Charles Street, Boston, Massachusetts 02114, USA
| | - Jeffrey Tao Cheng
- Eaton-Peabody Laboratory, Massachusetts Eye & Ear, 243 Charles Street, Boston, Massachusetts 02114, USA
| | - John J Rosowski
- Eaton-Peabody Laboratory, Massachusetts Eye & Ear, 243 Charles Street, Boston, Massachusetts 02114, USA
| |
Collapse
|
42
|
Abdala C, Luo P, Guardia Y. Swept-Tone Stimulus-Frequency Otoacoustic Emissions in Human Newborns. Trends Hear 2019; 23:2331216519889226. [PMID: 31789131 PMCID: PMC6887807 DOI: 10.1177/2331216519889226] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 10/16/2019] [Accepted: 10/24/2019] [Indexed: 11/21/2022] Open
Abstract
Several types of otoacoustic emissions have been characterized in newborns to study the maturational status of the cochlea at birth and to develop effective tests of hearing. The stimulus-frequency otoacoustic emission (SFOAE), a reflection-type emission elicited with a single low-level pure tone, is the least studied of these emissions and has not been comprehensively characterized in human newborns. The SFOAE has been linked to cochlear tuning and is sensitive to disruptions in cochlear gain (i.e., hearing loss) in adult subjects. In this study, we characterize SFOAEs evoked with rapidly sweeping tones in human neonates and consider the implications of our findings for human cochlear maturation. SFOAEs were measured in 29 term newborns within 72 hr of birth using swept tones presented at 2 oct/s across a four-octave frequency range (0.5–8 kHz); 20 normal-hearing young adults served as a control group. The prevalence of SFOAEs in newborns was as high as 90% (depending on how response “presence” was defined). Evidence of probe-tip leakage and abnormal ear-canal energy reflectance was observed in those ears with absent or unmeasurable SFOAEs. Results in the group of newborns with present stimulus-frequency emissions indicate that neonatal swept-tone SFOAEs are adult-like in morphology but have slightly higher amplitude compared with adults and longer SFOAE group delays. The origin of these nonadult-like features is probably mixed, including contributions from both conductive (ear canal and middle ear) and cochlear immaturities.
Collapse
Affiliation(s)
- Carolina Abdala
- Caruso Department of Otolaryngology, Auditory Research Center, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Ping Luo
- Caruso Department of Otolaryngology, Auditory Research Center, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Yeini Guardia
- Caruso Department of Otolaryngology, Auditory Research Center, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| |
Collapse
|
43
|
Nørgaard KR, Fernandez-Grande E, Laugesen S. A coupler-based calibration method for ear-probe microphones. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:2294. [PMID: 30404519 DOI: 10.1121/1.5064283] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2018] [Accepted: 09/26/2018] [Indexed: 06/08/2023]
Abstract
The calibration of ear-probe microphones can increase the precision of calibrating stimulus levels in situ and of measuring acoustic responses from the ear. This paper proposes a methodology to measure the sensitivity of an ear-probe microphone, requiring only an acoustic coupler and a calibrated reference microphone. The input impedance of the coupler is measured, enabled by a preliminary acoustic Thévenin calibration of the ear probe, and the plane-wave transfer impedance of the coupler is calculated analytically. Using these two quantities, the pressure transfer function between the reference microphone and the ear-probe microphone is estimated. This enables estimating the sensitivity of the ear-probe microphone. The proposed and an existing method were compared, resulting in substantially similar ear-probe microphone sensitivities. The proposed method is practically feasible in producing reliable measurements of sound pressure in the ear canal and calibrating stimulus levels in a clinical setting.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Department of Electrical Engineering, Acoustic Technology, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Efren Fernandez-Grande
- Department of Electrical Engineering, Acoustic Technology, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Søren Laugesen
- Interacoustics Research Unit, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| |
Collapse
|
44
|
Siegel JH, Nørgaard KR, Neely ST. Evanescent waves in simulated ear canals: Experimental demonstration and method for compensation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:2135. [PMID: 30404523 PMCID: PMC6185868 DOI: 10.1121/1.5058683] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 09/14/2018] [Accepted: 09/17/2018] [Indexed: 06/01/2023]
Abstract
Evanescent waves emerge from a small sound source that radiates into a waveguide with a larger cross-sectional area, but unlike planar waves, do not propagate far from the source. Evanescent waves thus contaminate in-ear calibration of acoustic stimuli. Measurements with an otoacoustic-emission (OAE) probe inserted at the entrance of long tubes of various diameters show a decline in the evanescent wave with distance from the source when advancing a probe tube through the OAE probe and into the long tube. The amplitude of the evanescent pressure increases with frequency and depends strongly on the diameter of the long tube. Modifying the shape of the aperture of the probe's sound source, thus effectively enlarging its diameter and redirecting acoustic flow, greatly reduced evanescent waves. The reduction in evanescent-wave pressure was observed in calibration cavities used to determine the Thévenin-equivalent source pressure and impedance of the probe. Errors in source calibrations were considerably larger in the unmodified configuration. An alternative method is proposed for calculation of acoustic source parameters that models the evanescent-wave pressure and reduces its influence on the calculation. This reduction greatly improves the quality of source calibrations, which should improve the accuracy of ear-canal impedance measurements and related quantities.
Collapse
Affiliation(s)
- Jonathan H Siegel
- Department of Communication Sciences and Disorders and Knowles Hearing Center, Northwestern University, 2240 Campus Drive, Evanston, Illinois 60208, USA
| | - Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Stephen T Neely
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| |
Collapse
|
45
|
Pure-Tone Audiometry With Forward Pressure Level Calibration Leads to Clinically-Relevant Improvements in Test–Retest Reliability. Ear Hear 2018; 39:946-957. [DOI: 10.1097/aud.0000000000000555] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
46
|
Bhatt IS. Supra-aural transducer-related artifact contributes to overestimation of noise-induced hearing loss. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 143:2055. [PMID: 29716271 PMCID: PMC10836961 DOI: 10.1121/1.5030924] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This study compared the effects of supra-aural and insert receivers on the prevalence of noise-induced hearing loss (NIHL) in young adults. NIHL prevalence was found to be substantially higher when hearing thresholds were obtained with supra-aural compared to insert receivers on the same subjects. Real-ear sound pressure levels at 4000, 6000, and 8000 Hz were the major predictors of notched-audiograms obtained with supra-aural headphones. Distortion-product otoacoustic emissions were not significantly different between ears with and without notched-audiograms obtained with supra-aural headphones. The results demonstrated that supra-aural transducer-related artifacts can mimic a notch-like pattern leading to overestimation of NIHL prevalence.
Collapse
Affiliation(s)
- Ishan S Bhatt
- Department of Communication Sciences & Disorders, Northern Arizona University, 208 East Pine Knoll Drive, Flagstaff, Arizona 86011, USA
| |
Collapse
|
47
|
Nørgaard KR, Neely ST, Rasetshwane DM. Quantifying undesired parallel components in Thévenin-equivalent acoustic source parameters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 143:1491. [PMID: 29604709 PMCID: PMC5856597 DOI: 10.1121/1.5026796] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The calibration of an ear probe to determine its Thévenin-equivalent acoustic source parameters facilitates the measurement of ear-canal impedance and reflectance. Existing calibration error metrics, used to evaluate the quality of a calibration, are unable to reveal undesired parallel components in the source parameters. Such parallel components can result from, e.g., a leak in the ear tip or improperly accounting for evanescent modes, and introduce errors into subsequent measurements of impedance and reflectance. This paper proposes a set of additional error metrics that are capable of detecting such parallel components by examining the causality of the source admittance in the frequency domain and estimating the source pressure in the time domain. The proposed and existing error metrics are applied to four different calibrations using two existing calibration methods, representing typical use cases and introducing deliberate parallel components. The results demonstrate the capability of the proposed error metrics in identifying various undesired components in the source parameters that might otherwise go undetected.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Stephen T Neely
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Daniel M Rasetshwane
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| |
Collapse
|
48
|
Lewis JD. The area discontinuity between probe and ear canal as a source of power-reflectance measurement-location variability. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 143:1106. [PMID: 29495737 DOI: 10.1121/1.5024360] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This study examined the effect of the area discontinuity between the measurement-probe sound source and ear canal on the plane-wave approximation of power reflectance. The area discontinuity was hypothesized to introduce measurement-location sensitivity to the power reflectance, especially above 5 kHz. Measurements were made in human and artificial ear canals (tubes coupled to an IEC711 ear simulator). In both cases, the power reflectance exhibited a high-frequency notch that decreased in frequency as the residual canal length increased. The area discontinuity between probe and canal was modeled as an inductance in series with the canal's acoustic impedance. To compensate for the effects of the discontinuity, the discontinuity's impedance was subtracted from the measured load impedance of the canal. In the artificial ears, compensation for the estimated area discontinuity removed the high-frequency notch and reduced the position dependence of the power reflectance. Subtracting the estimated discontinuity impedance from the load impedance in the human ears had a minimal effect on the power-reflectance measurement-location variability and magnitude of the high-frequency notch. The area-discontinuity between probe and ear canal is not supported as the primary source of measurement-variability in the plane-wave approximation of the power reflectance in human ears.
Collapse
Affiliation(s)
- James D Lewis
- Department of Audiology and Speech Pathology, University of Tennessee Health Science Center, Knoxville, Tennessee 37996, USA
| |
Collapse
|
49
|
Christensen AT, Abdala C, Shera CA. Probing Apical-Basal Differences in the Human Cochlea Using Distortion-Product Otoacoustic Emission Phase. AIP CONFERENCE PROCEEDINGS 2018; 1965. [PMID: 30089933 DOI: 10.1063/1.5038495] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Distortion-product otoacoustic emission (DPOAE) phase is shaped by interaction between the evoking stimulus waves. Near-invariant at high frequencies, DPOAE phase-vs-frequency functions measured at fixed ratios bend into sloping functions at low frequencies. The different phase behaviors observed suggest that the mechanics underlying the generation of OAEs differ in the halves of the cochlea. To map out the phenomenological extent of low-to-mid frequency phase bends, this study recorded DPOAE responses from 20 normal-hearing human adult ears for a wide range of stimulus frequencies, f1 and f2, where f2 frequency sweeps from 0.25 to 8 kHz, and the f2/ f1 ratio varies from 1.05 to 1.49. Our preliminary results show two transitions in the phase slopes. One near 2.6 kHz in agreement with the literature, and another of opposite polarity near 0.75 kHz which has not been reported before. We find that the f2 frequencies marking these defining phase features are invariant with stimulus ratio. Even as the underlying mechanics remain unknown, the invariance opens the door for DPOAE phase to reliably characterize apical-basal differences across age groups and species.
Collapse
Affiliation(s)
- Anders T Christensen
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, 1640 Marengo St, Los Angeles, CA 90033, USA
| | - Carolina Abdala
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, 1640 Marengo St, Los Angeles, CA 90033, USA
| | - Christopher A Shera
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, 1640 Marengo St, Los Angeles, CA 90033, USA
| |
Collapse
|
50
|
Nørgaard KR, Fernandez-Grande E, Laugesen S. Compensating for evanescent modes and estimating characteristic impedance in waveguide acoustic impedance measurements. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 142:3497. [PMID: 29289093 DOI: 10.1121/1.5016808] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The ear-canal acoustic impedance and reflectance are useful for assessing conductive hearing disorders and calibrating stimulus levels in situ. However, such probe-based measurements are affected by errors due to the presence of evanescent modes and incorrect estimates or assumptions regarding characteristic impedance. This paper proposes a method to compensate for evanescent modes in measurements of acoustic impedance, reflectance, and sound pressure in waveguides, as well as estimating the characteristic impedance immediately in front of the probe. This is achieved by adjusting the characteristic impedance and subtracting an acoustic inertance from the measured impedance such that the non-causality in the reflectance is minimized in the frequency domain using the Hilbert transform. The method is thus capable of estimating plane-wave quantities of the sought-for parameters by supplying only an arbitrary initial value for the characteristic impedance. From a comparison with a simulated waveguide, it is shown that this method can accurately estimate these quantities in a waveguide that is uniform at the position of the probe. Finally, it is demonstrated how evanescent modes, characteristic impedance, and the proposed methodology can affect the measured acoustic impedance and reflectance of an occluded-ear simulator.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Efren Fernandez-Grande
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Søren Laugesen
- Interacoustics Research Unit, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| |
Collapse
|