1
|
López-Ramos D, Eustaquio-Martín A, López-Bascuas LE, Lopez-Poveda EA. Effect of stimulus duration on estimates of human cochlear tuning. Hear Res 2024; 451:109080. [PMID: 39004016 DOI: 10.1016/j.heares.2024.109080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 06/21/2024] [Accepted: 07/10/2024] [Indexed: 07/16/2024]
Abstract
Auditory masking methods originally employed to assess behavioral frequency selectivity have evolved over the years to infer cochlear tuning. Behavioral forward masking thresholds for spectrally notched noise maskers and a fixed, low-level probe tone provide accurate estimates of cochlear tuning. Here, we use this method to investigate the effect of stimulus duration on human cochlear tuning at 500 Hz and 4 kHz. Probes were 20-ms sinusoids at 10 dB sensation level. Maskers were noises with a spectral notch symmetrically and asymmetrically placed around the probe frequency. For seven participants with normal hearing, masker levels at masking threshold were measured in forward masking for various notch widths and for masker durations of 30 and 400 ms. Measurements were fitted assuming rounded exponential filter shapes and the power spectrum model of masking, and equivalent rectangular bandwidths (ERBs) were inferred from the fits. At 4 kHz, masker thresholds were higher for the shorter maskers but ERBs were not significantly different for the two masker durations (ERB30ms=294 Hz vs. ERB400ms=277 Hz). At 500 Hz, by contrast, notched-noise curves were shallower for the 30-ms than the 400-ms masker, and ERBs were significantly broader for the shorter masker (ERB30ms=126 Hz vs. ERB400ms=55 Hz). We discuss possible factors that may underlay the duration effect at low frequencies and argue that it may not be possible to fully control for those factors. We conclude that tuning estimates are not affected by maker duration at high frequencies but should be measured and interpreted with caution at low frequencies.
Collapse
Affiliation(s)
- David López-Ramos
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, 37007 Salamanca, Spain; Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca, 37007 Salamanca, Spain
| | - Almudena Eustaquio-Martín
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, 37007 Salamanca, Spain; Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca, 37007 Salamanca, Spain
| | - Luis E López-Bascuas
- Departamento de Psicología Experimental, Procesos Cognitivos y Logopedia, Universidad Complutense de Madrid, 28223 Pozuelo de Alarcón, Madrid, Spain
| | - Enrique A Lopez-Poveda
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, 37007 Salamanca, Spain; Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca, 37007 Salamanca, Spain; Departamento de Cirugía, Facultad de Medicina, Universidad de Salamanca, 37007 Salamanca, Spain.
| |
Collapse
|
2
|
López-Ramos D, López-Bascuas LE, Eustaquio-Martín A, Lopez-Poveda EA. Effects of ipsilateral, contralateral, and bilateral noise precursors on psychoacoustical tuning curves in humans. Hear Res 2024; 453:109111. [PMID: 39276590 DOI: 10.1016/j.heares.2024.109111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Revised: 09/03/2024] [Accepted: 09/07/2024] [Indexed: 09/17/2024]
Abstract
Cochlear tuning and hence auditory frequency selectivity are thought to change in noisy environments by activation of the medial olivocochlear reflex (MOCR). In humans, auditory frequency selectivity is often assessed using psychoacoustical tuning curves (PTCs), a plot of the level required for pure-tone maskers to just mask a fixed-level pure-tone probe as a function of masker frequency. Sometimes, however, the stimuli used to measure a PTC are long enough that they can activate the MOCR by themselves and thus affect the PTC. Here, PTCs for probe frequencies of 500 Hz and 4 kHz were measured in forward masking using short maskers (30 ms) and probes (10 ms) to minimize the activation of the MOCR by the maskers or the probes. PTCs were also measured in the presence of long (300 ms) ipsilateral, contralateral, and bilateral broadband noise precursors to investigate the effect of the ipsilateral, contralateral, and bilateral MOCR on PTC tuning. Four listeners with normal hearing participated in the experiments. At 500 Hz, ipsilateral and bilateral precursors sharpened the PTCs by decreasing the thresholds for maskers with frequencies at or near the probe frequency with minimal effects on thresholds for maskers remote in frequency from the probe. At 4 kHz, by contrast, ipsilateral and bilateral precursors barely affected thresholds for maskers near the probe frequency but broadened PTCs by reducing thresholds for maskers far from the probe. Contralateral precursors barely affected PTCs. An existing computational model was used to interpret the results. The model suggested that despite the apparent differences, the pattern of results is consistent with the ipsilateral and bilateral MOCR inhibiting the cochlear gain similarly at the two probe frequencies and more strongly than the contralateral MOCR.
Collapse
Affiliation(s)
- David López-Ramos
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca 37007 Salamanca, Spain; Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca 37007 Salamanca, Spain
| | - Luis E López-Bascuas
- Departamento de Psicología Experimental, Procesos Cognitivos y Logopedia, Universidad Complutense de Madrid, 28223 Pozuelo de Alarcón, Madrid, Spain
| | - Almudena Eustaquio-Martín
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca 37007 Salamanca, Spain; Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca 37007 Salamanca, Spain
| | - Enrique A Lopez-Poveda
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca 37007 Salamanca, Spain; Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca 37007 Salamanca, Spain; Departamento de Cirugía, Facultad de Medicina, Universidad de Salamanca 37007 Salamanca, Spain.
| |
Collapse
|
3
|
Maxwell BN, Farhadi A, Brennan MA, Svec A, Carney LH. A Subcortical Model for Auditory Forward Masking with Efferent Control of Cochlear Gain. eNeuro 2024; 11:ENEURO.0365-24.2024. [PMID: 39231633 PMCID: PMC11419694 DOI: 10.1523/eneuro.0365-24.2024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2024] [Accepted: 08/26/2024] [Indexed: 09/06/2024] Open
Abstract
Previous physiological and psychophysical studies have explored whether feedback to the cochlea from the efferent system influences forward masking. The present work proposes that the limited growth-of-masking (GOM) observed in auditory nerve (AN) fibers may have been misunderstood; namely, that this limitation may be due to the influence of anesthesia on the efferent system. Building on the premise that the unanesthetized AN may exhibit GOM similar to more central nuclei, the present computational modeling study demonstrates that feedback from the medial olivocochlear (MOC) efferents may contribute to GOM observed physiologically in onset-type neurons in both the cochlear nucleus and inferior colliculus (IC). Additionally, the computational model of MOC efferents used here generates a decrease in masking with longer masker-signal delays similar to that observed in IC physiology and in psychophysical studies. An advantage of this explanation over alternative physiological explanations (e.g., that forward masking requires inhibition from the superior paraolivary nucleus) is that this theory can explain forward masking observed in the brainstem, early in the ascending pathway. For explaining psychoacoustic results, one strength of this model is that it can account for the lack of elevation in thresholds observed when masker level is randomly varied from interval-to-interval, a result that is difficult to explain using the conventional temporal window model of psychophysical forward masking. Future directions for evaluating the efferent mechanism as a contributing mechanism for psychoacoustic results are discussed.
Collapse
Affiliation(s)
- Braden N Maxwell
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14642
- Department of Neuroscience, University of Rochester, Rochester, New York 14642
| | - Afagh Farhadi
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York 14627
| | - Marc A Brennan
- Department of Special Education and Communication Disorders, University of Nebraska-Lincoln, Lincoln, Nebraska 68583
| | - Adam Svec
- Department of Audiology, San José State University, San José, California 95192
| | - Laurel H Carney
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14642
- Department of Neuroscience, University of Rochester, Rochester, New York 14642
| |
Collapse
|
4
|
Laback B, Tabuchi H, Kohlrausch A. Evidence for proactive and retroactive temporal pattern analysis in simultaneous maskinga). THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:3742-3759. [PMID: 38856312 DOI: 10.1121/10.0026240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Accepted: 05/17/2024] [Indexed: 06/11/2024]
Abstract
Amplitude modulation (AM) of a masker reduces its masking on a simultaneously presented unmodulated pure-tone target, which likely involves dip listening. This study tested the idea that dip-listening efficiency may depend on stimulus context, i.e., the match in AM peakedness (AMP) between the masker and a precursor or postcursor stimulus, assuming a form of temporal pattern analysis process. Masked thresholds were measured in normal-hearing listeners using Schroeder-phase harmonic complexes as maskers and precursors or postcursors. Experiment 1 showed threshold elevation (i.e., interference) when a flat cursor preceded or followed a peaked masker, suggesting proactive and retroactive temporal pattern analysis. Threshold decline (facilitation) was observed when the masker AMP was matched to the precursor, irrespective of stimulus AMP, suggesting only proactive processing. Subsequent experiments showed that both interference and facilitation (1) remained robust when a temporal gap was inserted between masker and cursor, (2) disappeared when an F0-difference was introduced between masker and precursor, and (3) decreased when the presentation level was reduced. These results suggest an important role of envelope regularity in dip listening, especially when masker and cursor are F0-matched and, therefore, form one perceptual stream. The reported effects seem to represent a time-domain variant of comodulation masking release.
Collapse
Affiliation(s)
- Bernhard Laback
- Austrian Academy of Sciences, Acoustics Research Institute, Wohllebengasse 12-14, 1040 Vienna, Austria
| | - Hisaaki Tabuchi
- Department of Psychology, University of Innsbruck, Universitätsstraße 15, 6020 Innsbruck, Austria
| | - Armin Kohlrausch
- Industrial Engineering & Innovation Sciences, Technische Universiteit Eindhoven, P.O. Box 513, 5600 MB Eindhoven, Netherlands
| |
Collapse
|
5
|
Ahissar E, Nelinger G, Assa E, Karp O, Saraf-Sinik I. Thalamocortical loops as temporal demodulators across senses. Commun Biol 2023; 6:562. [PMID: 37237075 DOI: 10.1038/s42003-023-04881-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 04/27/2023] [Indexed: 05/28/2023] Open
Abstract
Sensory information is coded in space and in time. The organization of neuronal activity in space maintains straightforward relationships with the spatial organization of the perceived environment. In contrast, the temporal organization of neuronal activity is not trivially related to external features due to sensor motion. Still, the temporal organization shares similar principles across sensory modalities. Likewise, thalamocortical circuits exhibit common features across senses. Focusing on touch, vision, and audition, we review their shared coding principles and suggest that thalamocortical systems include circuits that allow analogous recoding mechanisms in all three senses. These thalamocortical circuits constitute oscillations-based phase-locked loops, that translate temporally-coded sensory information to rate-coded cortical signals, signals that can integrate information across sensory and motor modalities. The loop also allows predictive locking to the onset of future modulations of the sensory signal. The paper thus suggests a theoretical framework in which a common thalamocortical mechanism implements temporal demodulation across senses.
Collapse
Affiliation(s)
- Ehud Ahissar
- Department of Brain Sciences, Weizmann Institute, Rehovot, 76100, Israel.
| | - Guy Nelinger
- Department of Brain Sciences, Weizmann Institute, Rehovot, 76100, Israel
| | - Eldad Assa
- Department of Brain Sciences, Weizmann Institute, Rehovot, 76100, Israel
| | - Ofer Karp
- Department of Brain Sciences, Weizmann Institute, Rehovot, 76100, Israel
| | - Inbar Saraf-Sinik
- Department of Brain Sciences, Weizmann Institute, Rehovot, 76100, Israel
| |
Collapse
|
6
|
Salloom WB, Bharadwaj H, Strickland EA. The effects of broadband elicitor duration on a psychoacoustic measure of cochlear gain reduction. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:2482. [PMID: 37092950 PMCID: PMC10257528 DOI: 10.1121/10.0017925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 03/31/2023] [Accepted: 04/07/2023] [Indexed: 05/03/2023]
Abstract
Physiological and psychoacoustic studies of the medial olivocochlear reflex (MOCR) in humans have often relied on long duration elicitors (>100 ms). This is largely due to previous research using otoacoustic emissions (OAEs) that found multiple MOCR time constants, including time constants in the 100s of milliseconds, when elicited by broadband noise. However, the effect of the duration of a broadband noise elicitor on similar psychoacoustic tasks is currently unknown. The current study measured the effects of ipsilateral broadband noise elicitor duration on psychoacoustic gain reduction estimated from a forward-masking paradigm. Analysis showed that both masker type and elicitor duration were significant main effects, but no interaction was found. Gain reduction time constants were ∼46 ms for the masker present condition and ∼78 ms for the masker absent condition (ranging from ∼29 to 172 ms), both similar to the fast time constants reported in the OAE literature (70-100 ms). Maximum gain reduction was seen for elicitor durations of ∼200 ms. This is longer than the 50-ms duration which was found to produce maximum gain reduction with a tonal on-frequency elicitor. Future studies of gain reduction may use 150-200 ms broadband elicitors to maximally or near-maximally stimulate the MOCR.
Collapse
Affiliation(s)
- William B Salloom
- Department of Speech Language and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| | - Hari Bharadwaj
- Department of Speech Language and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| | - Elizabeth A Strickland
- Department of Speech Language and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| |
Collapse
|
7
|
Acuña F, Jeria R, Pavez E, Aguilar-Vidal E. Efferent Control in Musicians: A Review. Audiol Res 2023; 13:76-85. [PMID: 36648928 PMCID: PMC9844302 DOI: 10.3390/audiolres13010007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 12/30/2022] [Accepted: 01/03/2023] [Indexed: 01/11/2023] Open
Abstract
It is widely established that musicians possess a higher level in certain auditory perceptual abilities when compared to non-musicians. This improvement may be mediated, at least in part, by changes in the cochlear response induced by reflex activation of the olivocochlear efferent system. In this review, we describe and analyze the scientific evidence regarding possible differences in the efferent response in musicians and non-musicians. The main evidence observed is that musicians present a greater robustness of the efferent olivocochlear reflex when measured by suppression of otoacoustic emissions and compared to non-musicians. Analyzing the articles presented in this review, it is possible to point out that the differential role of the efferent effect in musicians is not yet established. There is not enough evidence to support the idea that the olivocochlear system favors comparative changes in the properties of musicians' auditory filters. New studies with psychoacoustic techniques, among others, are needed to measure the effect of the olivocochlear reflex on tuning, gain, compression, or temporal resolution in musicians and non-musicians.
Collapse
Affiliation(s)
- Francisca Acuña
- Escuela de Tecnología Médica, Facultad de Medicina, Universidad de Chile, Santiago 8380453, Chile
| | - Rodrigo Jeria
- Escuela de Tecnología Médica, Facultad de Medicina, Universidad de Chile, Santiago 8380453, Chile
| | - Elisabeth Pavez
- Departamento de Tecnología Médica, Facultad de Medicina, Universidad de Chile, Santiago 8380453, Chile
| | - Enzo Aguilar-Vidal
- Departamento de Tecnología Médica, Facultad de Medicina, Universidad de Chile, Santiago 8380453, Chile
- Correspondence:
| |
Collapse
|
8
|
Temporal integration contributes to the masking release by amplitude modulation. Hear Res 2022; 420:108514. [DOI: 10.1016/j.heares.2022.108514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 03/29/2022] [Accepted: 05/04/2022] [Indexed: 11/18/2022]
|
9
|
DeRoy Milvae K, Strickland EA. Behavioral Measures of Cochlear Gain Reduction Depend on Precursor Frequency, Bandwidth, and Level. Front Neurosci 2021; 15:716689. [PMID: 34671236 PMCID: PMC8520990 DOI: 10.3389/fnins.2021.716689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Accepted: 09/06/2021] [Indexed: 11/25/2022] Open
Abstract
Sensory systems adjust to the environment to maintain sensitivity to change. In the auditory system, the medial olivocochlear reflex (MOCR) is a known physiological mechanism capable of such adjustment. The MOCR provides efferent feedback between the brainstem and cochlea, reducing cochlear gain in response to sound. The perceptual effects of the MOCR are not well understood, such as how gain reduction depends on elicitor characteristics in human listeners. Physiological and behavioral data suggest that ipsilateral MOCR tuning is only slightly broader than it is for afferent fibers, and that the fibers feed back to the frequency region of the cochlea that stimulated them. However, some otoacoustic emission (OAE) data suggest that noise is a more effective elicitor than would be consistent with sharp tuning, and that a broad region of the cochlea may be involved in elicitation. If the elicitor is processed in a cochlear channel centered at the signal frequency, the growth of gain reduction with elicitor level would be expected to depend on the frequency content of the elicitor. In the current study, the effects of the frequency content and level of a preceding sound (called a precursor) on signal threshold was examined. The results show that signal threshold increased with increasing precursor level at a shallower slope for a tonal precursor at the signal frequency than for a tonal precursor nearly an octave below the signal frequency. A broadband noise was only slightly more effective than a tone at the signal frequency, with a relatively shallow slope similar to that of the tonal precursor at the signal frequency. Overall, these results suggest that the excitation at the signal cochlear place, regardless of elicitor frequency, determines the magnitude of ipsilateral cochlear gain reduction, and that it increases with elicitor level.
Collapse
Affiliation(s)
- Kristina DeRoy Milvae
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN, United States
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN, United States
| |
Collapse
|
10
|
Salloom WB, Strickland EA. The effect of broadband elicitor laterality on psychoacoustic gain reduction across signal frequency. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 150:2817. [PMID: 34717476 PMCID: PMC8520488 DOI: 10.1121/10.0006662] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 09/17/2021] [Accepted: 09/21/2021] [Indexed: 05/19/2023]
Abstract
There are psychoacoustic methods thought to measure gain reduction, which may be from the medial olivocochlear reflex (MOCR), a bilateral feedback loop that adjusts cochlear gain. Although studies have used ipsilateral and contralateral elicitors and have examined strength at different signal frequencies, these factors have not been examined within a single study. Therefore, basic questions about gain reduction, such as the relative strength of ipsilateral vs contralateral elicitation and the relative strength across signal frequency, are not known. In the current study, gain reduction from ipsilateral, contralateral, and bilateral elicitors was measured at 1-, 2-, and 4-kHz signal frequencies using forward masking paradigms at a range of elicitor levels in a repeated measures design. Ipsilateral and bilateral strengths were similar and significantly larger than contralateral strength across signal frequencies. Growth of gain reduction with precursor level tended to differ with signal frequency, although not significantly. Data from previous studies are considered in light of the results of this study. Behavioral results are also considered relative to anatomical and physiological data on the MOCR. These results indicate that, in humans, cochlear gain reduction is broad across frequencies and is robust for ipsilateral and bilateral elicitation but small for contralateral elicitation.
Collapse
Affiliation(s)
- William B Salloom
- Department of Speech, Language, and Hearing Sciences, Purdue University, 715 Clinic Drive, West Lafayette, Indiana 47907, USA
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, 715 Clinic Drive, West Lafayette, Indiana 47907, USA
| |
Collapse
|
11
|
Jennings SG. The role of the medial olivocochlear reflex in psychophysical masking and intensity resolution in humans: a review. J Neurophysiol 2021; 125:2279-2308. [PMID: 33909513 PMCID: PMC8285664 DOI: 10.1152/jn.00672.2020] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 03/16/2021] [Accepted: 04/02/2021] [Indexed: 02/01/2023] Open
Abstract
This review addresses the putative role of the medial olivocochlear (MOC) reflex in psychophysical masking and intensity resolution in humans. A framework for interpreting psychophysical results in terms of the expected influence of the MOC reflex is introduced. This framework is used to review the effects of a precursor or contralateral acoustic stimulation on 1) simultaneous masking of brief tones, 2) behavioral estimates of cochlear gain and frequency resolution in forward masking, 3) the buildup and decay of forward masking, and 4) measures of intensity resolution. Support, or lack thereof, for a role of the MOC reflex in psychophysical perception is discussed in terms of studies on estimates of MOC strength from otoacoustic emissions and the effects of resection of the olivocochlear bundle in patients with vestibular neurectomy. Novel, innovative approaches are needed to resolve the dissatisfying conclusion that current results are unable to definitively confirm or refute the role of the MOC reflex in masking and intensity resolution.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Communication Sciences and Disorders, The University of Utah, Salt Lake City, Utah
| |
Collapse
|
12
|
DeRoy Milvae K, Alexander JM, Strickland EA. The relationship between ipsilateral cochlear gain reduction and speech-in-noise recognition at positive and negative signal-to-noise ratios. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:3449. [PMID: 34241110 PMCID: PMC8411890 DOI: 10.1121/10.0003964] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 03/09/2021] [Accepted: 03/11/2021] [Indexed: 06/13/2023]
Abstract
Active mechanisms that regulate cochlear gain are hypothesized to influence speech-in-noise perception. However, evidence of a relationship between the amount of cochlear gain reduction and speech-in-noise recognition is mixed. Findings may conflict across studies because different signal-to-noise ratios (SNRs) were used to evaluate speech-in-noise recognition. Also, there is evidence that ipsilateral elicitation of cochlear gain reduction may be stronger than contralateral elicitation, yet, most studies have investigated the contralateral descending pathway. The hypothesis that the relationship between ipsilateral cochlear gain reduction and speech-in-noise recognition depends on the SNR was tested. A forward masking technique was used to quantify the ipsilateral cochlear gain reduction in 24 young adult listeners with normal hearing. Speech-in-noise recognition was measured with the PRESTO-R sentence test using speech-shaped noise presented at -3, 0, and +3 dB SNR. Interestingly, greater cochlear gain reduction was associated with lower speech-in-noise recognition, and the strength of this correlation increased as the SNR became more adverse. These findings support the hypothesis that the SNR influences the relationship between ipsilateral cochlear gain reduction and speech-in-noise recognition. Future studies investigating the relationship between cochlear gain reduction and speech-in-noise recognition should consider the SNR and both descending pathways.
Collapse
Affiliation(s)
- Kristina DeRoy Milvae
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| | - Joshua M Alexander
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| |
Collapse
|
13
|
Abstract
OBJECTIVE The medial olivocochlear (MOC) reflex provides efferent feedback from the brainstem to cochlear outer hair cells. Physiologic studies have demonstrated that the MOC reflex is involved in "unmasking" of signals-in-noise at the level of the auditory nerve; however, its functional importance in human hearing remains unclear. DESIGN This study examined relationships between pre-neural measurements of MOC reflex strength (click-evoked otoacoustic emission inhibition; CEOAE) and neural measurements of speech-in-noise encoding (speech frequency following response; sFFR) in four conditions (Quiet, Contralateral Noise, Ipsilateral Noise, and Ipsilateral + Contralateral Noise). Three measures of CEOAE inhibition (amplitude reduction, effective attenuation, and input-output slope inhibition) were used to quantify pre-neural MOC reflex strength. Correlations between pre-neural MOC reflex strength and sFFR "unmasking" (i.e. response recovery from masking effects with activation of the MOC reflex in time and frequency domains) were assessed. STUDY SAMPLE 18 young adults with normal hearing. RESULTS sFFR unmasking effects were insignificant, and there were no correlations between pre-neural MOC reflex strength and sFFR unmasking in the time or frequency domain. CONCLUSION Our results do not support the hypothesis that the MOC reflex is involved in speech-in-noise neural encoding, at least for features that are represented in the sFFR at the SNR tested.
Collapse
Affiliation(s)
- S B Smith
- Department of Communication Sciences and Disorders, University of Texas at Austin, Austin, TX, USA
| | - B Cone
- Department of Speech, Language, and Hearing Sciences, University of Arizona, Tucson, AZ, USA
| |
Collapse
|
14
|
Liu Y, Xu R, Gong Q. Human Auditory-Frequency Tuning Is Sensitive to Tonal Language Experience. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2020; 63:4277-4288. [PMID: 33151817 DOI: 10.1044/2020_jslhr-20-00152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Purpose The aim of this study is to investigate whether human auditory frequency tuning can be influenced by tonal language experience. Method Perceptual tuning measured via psychophysical tuning curves and cochlear tuning derived via stimulus-frequency otoacoustic emission suppression tuning curves in 14 native speakers of a tonal language (Mandarin) were compared to those of 14 native speakers of a nontonal language (English) at 1 and 4 kHz. Results Group comparisons of both psychophysical tuning curves (p = .046) and stimulus-frequency otoacoustic emission suppression tuning curves (p = .007) in the 4-kHz region indicated sharper frequency tuning in the Mandarin-speaking group relative to the English-speaking group. The auditory tuning was better at the higher (4 kHz) than the lower (1 kHz) probe frequencies (p < .001). Conclusions The sharper auditory tuning in the 4-kHz cochlear region is associated with long-term tonal language (i.e., Mandarin) experience. Experience-dependent plasticity of tonal language may occur before the sound signal reaches central neural stages, as peripheral as the cochlea.
Collapse
Affiliation(s)
- Yin Liu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Runyi Xu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Qin Gong
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
- School of Medicine, Shanghai University, China
| |
Collapse
|
15
|
Jennings SG, Sivas K, Stone C. Effects of Masker Envelope Fluctuations on the Temporal Effect. J Assoc Res Otolaryngol 2018; 19:717-727. [PMID: 30128623 DOI: 10.1007/s10162-018-00688-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Accepted: 06/26/2018] [Indexed: 11/25/2022] Open
Abstract
Under certain conditions, detection thresholds in simultaneous masking improve when the onset of a short sinusoidal probe is delayed from the onset of a long masker. This improvement, known as the temporal effect, is largest for broadband maskers and is smaller or absent for narrowband maskers centered on the probe frequency. This study tests the hypothesis that small or absent temporal effects for narrowband maskers are due to the inherent temporal envelope fluctuations of Gaussian noise. Temporal effects were measured for narrowband noise maskers with fluctuating ("fluctuating maskers") and flattened ("flattened maskers") temporal envelopes as a function of masker level (Exp. I) and in the presence of fluctuating and flattened precursors (Exp. II). The temporal effect was absent for fluctuating narrowband maskers and as large as ~ 7 dB for flattened narrowband maskers. The AC-coupled power of the temporal envelopes of precursors and maskers accounted for 94 % of the variance in probe detection thresholds measured with fluctuating and flattened precursors and maskers. These results suggest that masker temporal envelope fluctuations contribute to the temporal effect and should be considered in future modeling efforts.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, UT, 84112, USA. .,Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge Avenue, MSC 550, Charleston, SC, 29425-5500, USA.
| | - Kayla Sivas
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, UT, 84112, USA
| | - Caitlin Stone
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, UT, 84112, USA
| |
Collapse
|
16
|
Moncada-Torres A, Joshi SN, Prokopiou A, Wouters J, Epp B, Francart T. A framework for computational modelling of interaural time difference discrimination of normal and hearing-impaired listeners. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:940. [PMID: 30180705 DOI: 10.1121/1.5051322] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Accepted: 08/03/2018] [Indexed: 06/08/2023]
Abstract
Different computational models have been developed to study the interaural time difference (ITD) perception. However, only few have used a physiologically inspired architecture to study ITD discrimination. Furthermore, they do not include aspects of hearing impairment. In this work, a framework was developed to predict ITD thresholds in listeners with normal and impaired hearing. It combines the physiologically inspired model of the auditory periphery proposed by Zilany, Bruce, Nelson, and Carney [(2009). J. Acoust. Soc. Am. 126(5), 2390-2412] as a front end with a coincidence detection stage and a neurometric decision device as a back end. It was validated by comparing its predictions against behavioral data for narrowband stimuli from literature. The framework is able to model ITD discrimination of normal-hearing and hearing-impaired listeners at a group level. Additionally, it was used to explore the effect of different proportions of outer- and inner-hair cell impairment on ITD discrimination.
Collapse
Affiliation(s)
- Arturo Moncada-Torres
- KU Leuven - University of Leuven, Department of Neurosciences, ExpORL, Herestraat 49, Bus 721, 3000 Leuven, Belgium
| | - Suyash N Joshi
- Department of Electrical Engineering, Hearing Systems, Technical University of Denmark, Ørsteds Plads, Building 352, DK-2800 Kongens Lyngby, Denmark
| | - Andreas Prokopiou
- KU Leuven - University of Leuven, Department of Neurosciences, ExpORL, Herestraat 49, Bus 721, 3000 Leuven, Belgium
| | - Jan Wouters
- KU Leuven - University of Leuven, Department of Neurosciences, ExpORL, Herestraat 49, Bus 721, 3000 Leuven, Belgium
| | - Bastian Epp
- Department of Electrical Engineering, Hearing Systems, Technical University of Denmark, Ørsteds Plads, Building 352, DK-2800 Kongens Lyngby, Denmark
| | - Tom Francart
- KU Leuven - University of Leuven, Department of Neurosciences, ExpORL, Herestraat 49, Bus 721, 3000 Leuven, Belgium
| |
Collapse
|
17
|
DeRoy Milvae K, Strickland EA. Psychoacoustic measurements of ipsilateral cochlear gain reduction as a function of signal frequency. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 143:3114. [PMID: 29857720 PMCID: PMC5967972 DOI: 10.1121/1.5038254] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 03/09/2018] [Accepted: 04/30/2018] [Indexed: 05/19/2023]
Abstract
Forward masking experiments at 4 kHz have demonstrated that preceding sound can elicit changes in masking patterns consistent with a change in cochlear gain. However, the acoustic environment is filled with complex sounds, often dominated by lower frequencies, and ipsilateral cochlear gain reduction at frequencies below 4 kHz is largely unstudied in the forward masking literature. In this experiment, the magnitude of ipsilateral cochlear gain reduction was explored at 1, 2, and 4 kHz using forward masking techniques in an effort to evaluate a range of frequencies in listeners with normal hearing. Gain reduction estimates were not significantly different at 2 and 4 kHz using two forward masking measurements. Although the frequency was a significant factor in the analysis, post hoc testing supported the interpretation that gain reduction estimates measured without a masker were not significantly different at 1, 2, and 4 kHz. A second experiment provided evidence that forward masking in this paradigm at 1 kHz cannot be explained by excitation alone. This study provides evidence of ipsilateral cochlear gain reduction in humans at frequencies below the 4 kHz region.
Collapse
Affiliation(s)
- Kristina DeRoy Milvae
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| |
Collapse
|
18
|
Verhey JL, van de Par S. Binaural frequency selectivity in humans. Eur J Neurosci 2018; 51:1179-1190. [PMID: 29359360 DOI: 10.1111/ejn.13837] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2017] [Revised: 01/09/2018] [Accepted: 01/10/2018] [Indexed: 11/30/2022]
Abstract
Several behavioural studies in humans have shown that listening to sounds with two ears that is binaural hearing, provides the human auditory system with extra information on the sound source that is not available when sounds are only perceived through one ear that is monaurally. Binaural processing involves the analysis of phase and level differences between the two ear signals. As monaural cochlea processing (in each ear) precedes the neural stages responsible for binaural processing properties it is reasonable to assume that properties of the cochlea may also be observed in binaural processing. A main characteristic of cochlea processing is its frequency selectivity. In psychoacoustics, there is an ongoing discussion on the frequency selectivity of the binaural auditory system. While some psychoacoustic experiments seem to indicate poorer frequency selectivity of the binaural system than that of the monaural processing others seem to indicate the same frequency selectivity for monaural and binaural processing. This study provides an overview of these seemingly controversial results and the different explanations that were provided to account for the different results.
Collapse
Affiliation(s)
- Jesko L Verhey
- Department of Experimental Audiology, Otto von Guericke University Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Steven van de Par
- Acoustic Group, Cluster of Excellence Hearing4All, Carl von Ossietzky University Oldenburg, Oldenburg, Germany
| |
Collapse
|
19
|
Olivocochlear efferents: Their action, effects, measurement and uses, and the impact of the new conception of cochlear mechanical responses. Hear Res 2017; 362:38-47. [PMID: 29291948 DOI: 10.1016/j.heares.2017.12.012] [Citation(s) in RCA: 102] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2017] [Revised: 11/08/2017] [Accepted: 12/12/2017] [Indexed: 12/27/2022]
Abstract
The anatomy and physiology of olivocochlear (OC) efferents are reviewed. To help interpret these, recent advances in cochlear mechanics are also reviewed. Lateral OC (LOC) efferents innervate primary auditory-nerve (AN) fiber dendrites. The most important LOC function may be to reduce auditory neuropathy. Medial OC (MOC) efferents innervate the outer hair cells (OHCs) and act to turn down the gain of cochlear amplification. Cochlear amplification had been thought to act only through basilar membrane (BM) motion, but recent reports show that motion near the reticular lamina (RL) is amplified more than BM motion, and that RL-motion amplification extends to several octaves below the local characteristic frequency. Data on efferent effects on AN-fiber responses, otoacoustic emissions (OAEs) and human psychophysics are reviewed and reinterpreted in the light of the new cochlear-mechanical data. The possible origin of OAEs in RL motion is considered. MOC-effect measuring methods and MOC-induced changes in human responses are also reviewed, including that ipsilateral and contralateral sound can produce MOC effects with different patterns across frequency. MOC efferents help to reduce damage due to acoustic trauma. Many, but not all, reports show that subjects with stronger contralaterally-evoked MOC effects have better ability to detect signals (e.g. speech) in noise, and that MOC effects can be modulated by attention.
Collapse
|
20
|
Clark NR, Lecluyse W, Jürgens T. Analysis of compressive properties of the BioAid hearing aid algorithm. Int J Audiol 2017; 57:S130-S138. [PMID: 28942716 DOI: 10.1080/14992027.2017.1378931] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVE This technical paper describes a biologically inspired hearing aid algorithm based on a computer model of the peripheral auditory system simulating basilar membrane compression, reflexive efferent feedback and its resulting properties. DESIGN Two evaluations were conducted on the core part of the algorithm, which is an instantaneous compression sandwiched between the attenuation and envelope extraction processes of a relatively slow feedback compressor. STUDY SAMPLE The algorithm's input/output (I/O) function was analysed for different stationary (ambient) sound levels, and the algorithm's response to transient sinusoidal tone complexes was analysed and contrasted to that of a reference dynamic compressor. RESULTS The algorithm's emergent properties are: (1) the I/O function adapts to the average sound level such that processing is linear for levels close to the ambient sound level and (2) onsets of transient signals are marked across time and frequency. CONCLUSION Adaptive linearisation and onset marking, as inherent compressive features of the algorithm, provide potentially beneficial features to hearing-impaired listeners with a relatively simple circuit. The algorithm offers a new, biological perspective on hearing aid amplification.
Collapse
Affiliation(s)
| | - Wendy Lecluyse
- b Department of Children, Young People and Education , University Campus Suffolk , Ipswich , UK , and
| | - Tim Jürgens
- c Medizinische Physik, Forschungszentrum Neurosensorik, and Cluster of Excellence "Hearing4all" , Carl-von-Ossietzky Universität Oldenburg , Oldenburg , Germany
| |
Collapse
|
21
|
Verschooten E, Strickland EA, Verhaert N, Joris PX. Assessment of Ipsilateral Efferent Effects in Human via ECochG. Front Neurosci 2017; 11:331. [PMID: 28642679 PMCID: PMC5462931 DOI: 10.3389/fnins.2017.00331] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2017] [Accepted: 05/26/2017] [Indexed: 11/16/2022] Open
Abstract
Development of electrophysiological means to assess the medial olivocochlear (MOC) system in humans is important to further our understanding of the function of that system and for the refinement and validation of psychoacoustical and otoacoustic emission methods which are thought to probe the MOC. Based on measurements in anesthetized animals it has been hypothesized that the MOC-reflex (MOCR) can enhance the response to signals in noise, and several lines of evidence support such a role in humans. A difficulty in these studies is the isolation of efferent effects. Efferent activation can be triggered by acoustic stimulation of the contralateral or ipsilateral ear, but ipsilateral stimulation is thought to be more effective. However, ipsilateral stimulation complicates interpretation of effects since these sounds can affect the perception of other ipsilateral sounds by mechanisms not involving olivocochlear efferents. We assessed the ipsilaterally evoked MOCR in human using a transtympanic procedure to record mass-potentials from the cochlear promontory or the niche of the round window. Averaged compound action potential (CAP) responses to masked probe tones of 4 kHz with and without a precursor (designed to activate the MOCR but not the stapedius reflex) were extracted with a polarity alternating paradigm. The masker was either a simultaneous narrow band noise masker or a short (20-ms) tonal ON- or OFF-frequency forward masker. The subjects were screened for normal hearing (audiogram, tympanogram, threshold stapedius reflex) and psychoacoustically tested for the presence of a precursor effect. We observed a clear reduction of CAP amplitude by the precursor, for different masking conditions. Even without an MOCR, this is expected because the precursor will affect the response to subsequent stimuli via neural adaptation. To determine whether the precursor also activated the efferent system, we measured the CAP over a range of masker levels, with or without precursor, and for different types of masker. The results show CAP reduction consistent with the type of gain reduction caused by the MOCR. These results generally support psychoacoustical paradigms designed to probe the efferent system as indeed activating the MOCR system, but not all observations are consistent with this mechanism.
Collapse
Affiliation(s)
- Eric Verschooten
- Laboratory of Auditory Neurophysiology, Department of Neurosciences, University of LeuvenLeuven, Belgium
| | - Elizabeth A. Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue UniversityWest Lafayette, IN, United States
| | - Nicolas Verhaert
- ExpORL Research Group, Department of Neurosciences, University of LeuvenLeuven, Belgium
| | - Philip X. Joris
- Laboratory of Auditory Neurophysiology, Department of Neurosciences, University of LeuvenLeuven, Belgium
| |
Collapse
|
22
|
Verhey JL, Kordus M, Drga V, Yasin I. Effect of efferent activation on binaural frequency selectivity. Hear Res 2017; 350:152-159. [PMID: 28494386 DOI: 10.1016/j.heares.2017.04.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 04/04/2017] [Accepted: 04/28/2017] [Indexed: 10/19/2022]
Abstract
Binaural notched-noise experiments indicate a reduced frequency selectivity of the binaural system compared to monaural processing. The present study investigates how auditory efferent activation (via the medial olivocochlear system) affects binaural frequency selectivity in normal-hearing listeners. Thresholds were measured for a 1-kHz signal embedded in a diotic notched-noise masker for various notch widths. The signal was either presented in phase (diotic) or in antiphase (dichotic), gated with the noise. Stimulus duration was 25 ms, in order to avoid efferent activation due to the masker or the signal. A bandpass-filtered noise precursor was presented prior to the masker and signal stimuli to activate the efferent system. The silent interval between the precursor and the masker-signal complex was 50 ms. For comparison, thresholds for detectability of the masked signal were also measured in a baseline condition without the precursor and, in addition, without the masker. On average, the results of the baseline condition indicate an effectively wider binaural filter, as expected. For both signal phases, the addition of the precursor results in effectively wider filters, which is in agreement with the hypothesis that cochlear gain is reduced due to the presence of the precursor.
Collapse
Affiliation(s)
- Jesko L Verhey
- Department of Experimental Audiology, Otto von Guericke University, Leipziger Str. 44, 39120 Magdeburg, Germany.
| | - Monika Kordus
- Department of Experimental Audiology, Otto von Guericke University, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Vit Drga
- Department of Computer Science, University College London, Malet Place, London WC1E 6BT, United Kingdom
| | - Ifat Yasin
- Department of Computer Science, University College London, Malet Place, London WC1E 6BT, United Kingdom
| |
Collapse
|
23
|
Moncada-Torres A, van Wieringen A, Bruce IC, Wouters J, Francart T. Predicting phoneme and word recognition in noise using a computational model of the auditory periphery. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 141:300. [PMID: 28147586 DOI: 10.1121/1.4973569] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Several filterbank-based metrics have been proposed to predict speech intelligibility (SI). However, these metrics incorporate little knowledge of the auditory periphery. Neurogram-based metrics provide an alternative, incorporating knowledge of the physiology of hearing by using a mathematical model of the auditory nerve response. In this work, SI was assessed utilizing different filterbank-based metrics (the speech intelligibility index and the speech-based envelope power spectrum model) and neurogram-based metrics, using the biologically inspired model of the auditory nerve proposed by Zilany, Bruce, Nelson, and Carney [(2009), J. Acoust. Soc. Am. 126(5), 2390-2412] as a front-end and the neurogram similarity metric and spectro temporal modulation index as a back-end. Then, the correlations with behavioural scores were computed. Results showed that neurogram-based metrics representing the speech envelope showed higher correlations with the behavioural scores at a word level. At a per-phoneme level, it was found that phoneme transitions contribute to higher correlations between objective measures that use speech envelope information at the auditory periphery level and behavioural data. The presented framework could function as a useful tool for the validation and tuning of speech materials, as well as a benchmark for the development of speech processing algorithms.
Collapse
Affiliation(s)
- Arturo Moncada-Torres
- Department of Neurosciences, ExpORL, KU Leuven, Herestraat 49, Bus 721, 3000 Leuven, Belgium
| | - Astrid van Wieringen
- Department of Neurosciences, ExpORL, KU Leuven, Herestraat 49, Bus 721, 3000 Leuven, Belgium
| | - Ian C Bruce
- Department of Neurosciences, ExpORL, KU Leuven, Herestraat 49, Bus 721, 3000 Leuven, Belgium
| | - Jan Wouters
- Department of Neurosciences, ExpORL, KU Leuven, Herestraat 49, Bus 721, 3000 Leuven, Belgium
| | - Tom Francart
- Department of Neurosciences, ExpORL, KU Leuven, Herestraat 49, Bus 721, 3000 Leuven, Belgium
| |
Collapse
|
24
|
Necciari T, Laback B, Savel S, Ystad S, Balazs P, Meunier S, Kronland-Martinet R. Auditory Time-Frequency Masking for Spectrally and Temporally Maximally-Compact Stimuli. PLoS One 2016; 11:e0166937. [PMID: 27875575 PMCID: PMC5119819 DOI: 10.1371/journal.pone.0166937] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2016] [Accepted: 11/07/2016] [Indexed: 11/18/2022] Open
Abstract
Many audio applications perform perception-based time-frequency (TF) analysis by decomposing sounds into a set of functions with good TF localization (i.e. with a small essential support in the TF domain) using TF transforms and applying psychoacoustic models of auditory masking to the transform coefficients. To accurately predict masking interactions between coefficients, the TF properties of the model should match those of the transform. This involves having masking data for stimuli with good TF localization. However, little is known about TF masking for mathematically well-localized signals. Most existing masking studies used stimuli that are broad in time and/or frequency and few studies involved TF conditions. Consequently, the present study had two goals. The first was to collect TF masking data for well-localized stimuli in humans. Masker and target were 10-ms Gaussian-shaped sinusoids with a bandwidth of approximately one critical band. The overall pattern of results is qualitatively similar to existing data for long maskers. To facilitate implementation in audio processing algorithms, a dataset provides the measured TF masking function. The second goal was to assess the potential effect of auditory efferents on TF masking using a modeling approach. The temporal window model of masking was used to predict present and existing data in two configurations: (1) with standard model parameters (i.e. without efferents), (2) with cochlear gain reduction to simulate the activation of efferents. The ability of the model to predict the present data was quite good with the standard configuration but highly degraded with gain reduction. Conversely, the ability of the model to predict existing data for long maskers was better with than without gain reduction. Overall, the model predictions suggest that TF masking can be affected by efferent (or other) effects that reduce cochlear gain. Such effects were avoided in the experiment of this study by using maximally-compact stimuli.
Collapse
Affiliation(s)
- Thibaud Necciari
- Acoustics Research Institute, Austrian Academy of Sciences, Vienna, Austria
| | - Bernhard Laback
- Acoustics Research Institute, Austrian Academy of Sciences, Vienna, Austria
| | - Sophie Savel
- Laboratoire de Mécanique et d’Acoustique, CNRS UPR 7051, Equipe Sons, Aix-Marseille Université, Centrale Marseille, Marseille, France
| | - Sølvi Ystad
- Laboratoire de Mécanique et d’Acoustique, CNRS UPR 7051, Equipe Sons, Aix-Marseille Université, Centrale Marseille, Marseille, France
| | - Peter Balazs
- Acoustics Research Institute, Austrian Academy of Sciences, Vienna, Austria
| | - Sabine Meunier
- Laboratoire de Mécanique et d’Acoustique, CNRS UPR 7051, Equipe Sons, Aix-Marseille Université, Centrale Marseille, Marseille, France
| | - Richard Kronland-Martinet
- Laboratoire de Mécanique et d’Acoustique, CNRS UPR 7051, Equipe Sons, Aix-Marseille Université, Centrale Marseille, Marseille, France
| |
Collapse
|
25
|
Tabuchi H, Laback B, Necciari T, Majdak P. The role of compression in the simultaneous masker phase effect. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:2680. [PMID: 27794305 PMCID: PMC5714264 DOI: 10.1121/1.4964328] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Peripheral compression is believed to play a major role in the masker phase effect (MPE). While compression is almost instantaneous, activation of the efferent system reduces compression in a temporally evolving manner. To study the role of efferent-controlled compression in the MPE, in experiment 1, simultaneous masking of a 30-ms 4-kHz tone by 40-ms Schroeder-phase harmonic complexes was measured with on- and off-frequency precursors as a function of masker phase curvature for two masker levels (60 and 90 dB sound pressure level). The MPE was quantified by the threshold range [min/max difference (MMD)] across the phase curvatures. For the 60-dB condition, the presence of on-frequency precursor decreased the MMD from 10 to 5 dB. Experiment 2 studied the role of the precursor on the auditory filter's bandwidth. The on-frequency precursor was found to increase the bandwidth, an effect incorporated in the subsequent modeling. A model of the auditory periphery including cochlear filtering and basilar membrane compression generally underestimated the MMDs. A model based on two-step compression, including compression of inner hair cells, accounted for the MMDs across precursor and level conditions. Overall, the observed precursor effects and the model predictions suggest an important role of compression in the simultaneous MPE.
Collapse
Affiliation(s)
- Hisaaki Tabuchi
- Austrian Academy of Sciences, Acoustics Research Institute, Wohllebengasse 12-14, 1040 Vienna, Austria
| | - Bernhard Laback
- Austrian Academy of Sciences, Acoustics Research Institute, Wohllebengasse 12-14, 1040 Vienna, Austria
| | - Thibaud Necciari
- Austrian Academy of Sciences, Acoustics Research Institute, Wohllebengasse 12-14, 1040 Vienna, Austria
| | - Piotr Majdak
- Austrian Academy of Sciences, Acoustics Research Institute, Wohllebengasse 12-14, 1040 Vienna, Austria
| |
Collapse
|
26
|
Jennings SG, Ahlstrom JB, Dubno JR. Effects of age and hearing loss on overshoot. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:2481. [PMID: 27794300 PMCID: PMC5065574 DOI: 10.1121/1.4964267] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Revised: 09/19/2016] [Accepted: 09/21/2016] [Indexed: 06/01/2023]
Abstract
The detection of a brief, sinusoidal probe in a long broadband, simultaneous masker improves as the probe is delayed from the masker's onset. This improvement ("overshoot") may be mediated by a reduction in cochlear amplifier gain over the timecourse of the masker via the medial olivocochlear (MOC) reflex. Overshoot was measured in younger adults with normal hearing and in older adults with normal and impaired hearing to test the hypothesis that aging and cochlear hearing loss result in abnormal overshoot, consistent with changes in certain structures along the MOC pathway. Overshoot decreased with increasing quiet probe thresholds and was only minimally influenced by increasing age. Marked individual differences in overshoot were observed due to differences in masking thresholds for probes presented near the masker's onset. Model simulations support the interpretation that reduced overshoot in hearing-impaired listeners is due to limited cochlear amplifier gain and therefore less gain to adjust over the timecourse of the masker. Similar overshoot among younger and older adults with normal hearing suggests that age-related changes to mechanisms underlying overshoot do not result in significant differences in overshoot among younger and older adults with normal hearing.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, Behavioral Science Building 1201, Salt Lake City, Utah 84112, USA
| | - Jayne B Ahlstrom
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge Avenue, MSC 550, Charleston, South Carolina 29425-5500, USA
| | - Judy R Dubno
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge Avenue, MSC 550, Charleston, South Carolina 29425-5500, USA
| |
Collapse
|
27
|
Langner F, Jürgens T. Forward-Masked Frequency Selectivity Improvements in Simulated and Actual Cochlear Implant Users Using a Preprocessing Algorithm. Trends Hear 2016; 20:20/0/2331216516659632. [PMID: 27604785 PMCID: PMC5017570 DOI: 10.1177/2331216516659632] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Frequency selectivity can be quantified using masking paradigms, such as psychophysical tuning curves (PTCs). Normal-hearing (NH) listeners show sharp PTCs that are level- and frequency-dependent, whereas frequency selectivity is strongly reduced in cochlear implant (CI) users. This study aims at (a) assessing individual shapes of PTCs in CI users, (b) comparing these shapes to those of simulated CI listeners (NH listeners hearing through a CI simulation), and (c) increasing the sharpness of PTCs using a biologically inspired dynamic compression algorithm, BioAid, which has been shown to sharpen the PTC shape in hearing-impaired listeners. A three-alternative-forced-choice forward-masking technique was used to assess PTCs in 8 CI users (with their own speech processor) and 11 NH listeners (with and without listening through a vocoder to simulate electric hearing). CI users showed flat PTCs with large interindividual variability in shape, whereas simulated CI listeners had PTCs of the same average flatness, but more homogeneous shapes across listeners. The algorithm BioAid was used to process the stimuli before entering the CI users’ speech processor or the vocoder simulation. This algorithm was able to partially restore frequency selectivity in both groups, particularly in seven out of eight CI users, meaning significantly sharper PTCs than in the unprocessed condition. The results indicate that algorithms can improve the large-scale sharpness of frequency selectivity in some CI users. This finding may be useful for the design of sound coding strategies particularly for situations in which high frequency selectivity is desired, such as for music perception.
Collapse
Affiliation(s)
- Florian Langner
- Medizinische Physik, Cluster of Excellence "Hearing4all," Carl von Ossietzky University, Oldenburg, Germany Forschungszentrum Neurosensorik, Carl von Ossietzky University, Oldenburg, Germany Department of Otolaryngology, Medical University Hannover, Hannover, Germany
| | - Tim Jürgens
- Medizinische Physik, Cluster of Excellence "Hearing4all," Carl von Ossietzky University, Oldenburg, Germany Forschungszentrum Neurosensorik, Carl von Ossietzky University, Oldenburg, Germany
| |
Collapse
|
28
|
Abstract
Perception of external objects involves sensory acquisition via the relevant sensory organs. A widely-accepted assumption is that the sensory organ is the first station in a serial chain of processing circuits leading to an internal circuit in which a percept emerges. This open-loop scheme, in which the interaction between the sensory organ and the environment is not affected by its concurrent downstream neuronal processing, is strongly challenged by behavioral and anatomical data. We present here a hypothesis in which the perception of external objects is a closed-loop dynamical process encompassing loops that integrate the organism and its environment and converging towards organism-environment steady-states. We discuss the consistency of closed-loop perception (CLP) with empirical data and show that it can be synthesized in a robotic setup. Testable predictions are proposed for empirical distinction between open and closed loop schemes of perception.
Collapse
Affiliation(s)
- Ehud Ahissar
- Department of Neurobiology, Weizmann Institute of Science, Rehovot, Israel
| | - Eldad Assa
- Department of Neurobiology, Weizmann Institute of Science, Rehovot, Israel
| |
Collapse
|
29
|
Stimulus Frequency Otoacoustic Emissions Provide No Evidence for the Role of Efferents in the Enhancement Effect. J Assoc Res Otolaryngol 2015; 16:613-29. [PMID: 26153415 DOI: 10.1007/s10162-015-0534-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Accepted: 06/18/2015] [Indexed: 10/23/2022] Open
Abstract
Auditory enhancement refers to the perceptual phenomenon that a target sound is heard out more readily from a background sound if the background is presented alone first. Here we used stimulus-frequency otoacoustic emissions (SFOAEs) to test the hypothesis that activation of the medial olivocochlear efferent system contributes to auditory enhancement effects. The SFOAEs were used as a tool to measure changes in cochlear responses to a target component and the neighboring components of a multitone background between conditions producing enhancement and conditions producing no enhancement. In the "enhancement" condition, the target and multitone background were preceded by a precursor stimulus with a spectral notch around the signal frequency; in the control (no-enhancement) condition, the target and multitone background were presented without the precursor. In an experiment using a wideband multitone stimulus known to produce significant psychophysical enhancement effects, SFOAEs showed no changes consistent with enhancement, but some aspects of the results indicated possible contamination of the SFOAE magnitudes by the activation of the middle-ear-muscle reflex. The same SFOAE measurements performed using narrower-band stimuli at lower sound levels also showed no SFOAE changes consistent with either absolute or relative enhancement despite robust psychophysical enhancement effects observed in the same listeners with the same stimuli. The results suggest that cochlear efferent control does not play a significant role in auditory enhancement effects.
Collapse
|
30
|
Wojtczak M, Beim JA, Oxenham AJ. Exploring the role of feedback-based auditory reflexes in forward masking by schroeder-phase complexes. J Assoc Res Otolaryngol 2014; 16:81-99. [PMID: 25338224 DOI: 10.1007/s10162-014-0495-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Accepted: 10/02/2014] [Indexed: 10/24/2022] Open
Abstract
Several studies have postulated that psychoacoustic measures of auditory perception are influenced by efferent-induced changes in cochlear responses, but these postulations have generally remained untested. This study measured the effect of stimulus phase curvature and temporal envelope modulation on the medial olivocochlear reflex (MOCR) and on the middle-ear muscle reflex (MEMR). The role of the MOCR was tested by measuring changes in the ear-canal pressure at 6 kHz in the presence and absence of a band-limited harmonic complex tone with various phase curvatures, centered either at (on-frequency) or well below (off-frequency) the 6-kHz probe frequency. The influence of possible MEMR effects was examined by measuring phase-gradient functions for the elicitor effects and by measuring changes in the ear-canal pressure with a continuous suppressor of the 6-kHz probe. Both on- and off-frequency complex tone elicitors produced significant changes in ear canal sound pressure. However, the pattern of results was not consistent with the earlier hypotheses postulating that efferent effects produce the psychoacoustic dependence of forward-masked thresholds on masker phase curvature. The results also reveal unexpectedly long time constants associated with some efferent effects, the source of which remains unknown.
Collapse
Affiliation(s)
- Magdalena Wojtczak
- Department of Psychology, University of Minnesota, N218 Elliott Hall, 75 East River Rd., Minneapolis, MN, 55455, USA,
| | | | | |
Collapse
|
31
|
Jennings SG, Ahlstrom JB, Dubno JR. Computational modeling of individual differences in behavioral estimates of cochlear nonlinearities. J Assoc Res Otolaryngol 2014; 15:945-60. [PMID: 25266264 DOI: 10.1007/s10162-014-0486-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Accepted: 09/01/2014] [Indexed: 02/07/2023] Open
Abstract
Temporal masking curves (TMCs) are often used to estimate cochlear compression in individuals with normal and impaired hearing. These estimates may yield a wide range of individual differences, even among subjects with similar quiet thresholds. This study used an auditory model to assess potential sources of variance in TMCs from 51 listeners in Poling et al. [J Assoc Res Otolaryngol, 13:91-108 (2012)]. These sources included threshold elevation, the contribution of outer and inner hair cell dysfunction to threshold elevation, compression of the off-frequency linear reference, and detection efficiency. Simulations suggest that detection efficiency is a primary factor contributing to individual differences in TMCs measured in normal-hearing subjects, while threshold elevation and the contribution of outer and inner hair cell dysfunction are primary factors in hearing-impaired subjects. Approximating the most compressive growth rate of the cochlear response from TMCs was achieved only in subjects with the highest detection efficiency. Simulations included off-frequency nonlinearity in basilar membrane and inner hair cell processing; however, this nonlinearity did not improve predictions, suggesting that other sources, such as the decay of masking and the strength of the medial olivocochlear reflex, may mimic off-frequency nonlinearity. Findings from this study suggest that sources of individual differences can play a strong role in behavioral estimates of compression, and these sources should be considered when using forward masking to study cochlear function in individual listeners or across groups of listeners.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, UT, 84112, USA,
| | | | | |
Collapse
|
32
|
Effects of contralateral acoustic stimulation on spontaneous otoacoustic emissions and hearing threshold fine structure. J Assoc Res Otolaryngol 2014; 15:897-914. [PMID: 25245498 DOI: 10.1007/s10162-014-0485-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2014] [Accepted: 08/18/2014] [Indexed: 10/24/2022] Open
Abstract
Medial olivocochlear (MOC) influence on cochlear mechanics can be noninvasively, albeit indirectly, explored via the effects of contralateral acoustic stimulation (CAS) on otoacoustic emissions. CAS-mediated effects are particularly pronounced for spontaneous otoacoustic emissions (SOAEs), which are typically reduced in amplitude and shifted upward in frequency by CAS. We investigated whether similar frequency shifts and magnitude reductions were observed behaviorally in the fine structure of pure-tone hearing thresholds, a phenomenon thought to share a common underlying mechanism with SOAEs. In normal-hearing listeners, fine-resolution thresholds were obtained over a narrow frequency range centered on the frequency of an SOAE, both in the absence and presence of 60-dB SPL broadband CAS. While CAS shifted threshold fine structure patterns and SOAEs upward in frequency by a comparable amount, little reduction in the presence or depth of fine structure was observed at frequencies near those of SOAEs. In fact, CAS typically improved thresholds, particularly at threshold minima, and increased fine structure depth when reductions in the amplitude of the associated SOAE were less than 10 dB. Additional measurements made at frequencies distant from SOAEs, or near SOAEs that were more dramatically reduced in amplitude by the CAS, revealed that CAS tended to elevate thresholds and reduce threshold fine structure depth. The results suggest that threshold fine structure is sensitive to MOC-mediated changes in cochlear gain, but that SOAEs complicate the interpretation of threshold measurements at nearby frequencies, perhaps due to masking or other interference effects. Both threshold fine structure and SOAEs may be significant sources of intersubject and intrasubject variability in psychoacoustic investigations of MOC function.
Collapse
|
33
|
Wicher A, Moore BCJ. Effect of broadband and narrowband contralateral noise on psychophysical tuning curves and otoacoustic emissions. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 135:2931-2941. [PMID: 24815273 DOI: 10.1121/1.4871358] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The relative effectiveness of narrowband and broadband noises in activating the efferent system was assessed by comparing the effect of contralateral stimulation (CS) with such sounds on psychophysical tuning curves (PTCs) determined in simultaneous masking, using signal frequencies of 1000 or 2000 Hz. To check that the CS stimuli used did activate the efferent system, distortion product otoacoustic emissions (DPOAEs) were also measured in the absence and presence of narrowband and broadband CS. The CS had no consistent effect on the masker level at the tips of the PTCs. A broadband pink noise CS consistently reduced the masker level required for threshold on both the low- and high-frequency sides of the PTCs for the 2000-Hz signal frequency. However, there were no consistent effects of the CS for any other case. The broadband pink noise CS had a greater effect in reducing DPOAE levels than the narrowband CS. The results provide psychophysical evidence supporting the idea that the efferent system is activated more effectively by a broadband than by a narrowband CS, at least for a signal frequency of 2000 Hz.
Collapse
Affiliation(s)
- Andrzej Wicher
- Institute of Acoustics, Faculty of Physics, Adam Mickiewicz University, 85 Umultowska, 61-614 Poznan, Poland
| | - Brian C J Moore
- Department of Experimental Psychology, Cambridge University, Downing Street, Cambridge CB2 3EB, England
| |
Collapse
|
34
|
Roverud E, Strickland EA. Accounting for nonmonotonic precursor duration effects with gain reduction in the temporal window model. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 135:1321-34. [PMID: 24606271 PMCID: PMC3985874 DOI: 10.1121/1.4864783] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2013] [Revised: 01/23/2014] [Accepted: 01/27/2014] [Indexed: 05/19/2023]
Abstract
The mechanisms of forward masking are not clearly understood. The temporal window model (TWM) proposes that masking occurs via a neural mechanism that integrates within a temporal window. The medial olivocochlear reflex (MOCR), a sound-evoked reflex that reduces cochlear amplifier gain, may also contribute to forward masking if the preceding sound reduces gain for the signal. Psychophysical evidence of gain reduction can be observed using a growth of masking (GOM) paradigm with an off-frequency forward masker and a precursor. The basilar membrane input/output (I/O) function is estimated from the GOM function, and the I/O function gain is reduced by the precursor. In this study, the effect of precursor duration on this gain reduction effect was examined for on- and off-frequency precursors. With on-frequency precursors, thresholds increased with increasing precursor duration, then decreased (rolled over) for longer durations. Thresholds with off-frequency precursors continued to increase with increasing precursor duration. These results are not consistent with solely neural masking, but may reflect gain reduction that selectively affects on-frequency stimuli. The TWM was modified to include history-dependent gain reduction to simulate the MOCR, called the temporal window model-gain reduction (TWM-GR). The TWM-GR predicted rollover and the differences with on- and off-frequency precursors whereas the TWM did not.
Collapse
Affiliation(s)
- Elin Roverud
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907-2038
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907-2038
| |
Collapse
|
35
|
Aguilar E, Eustaquio-Martin A, Lopez-Poveda EA. Contralateral efferent reflex effects on threshold and suprathreshold psychoacoustical tuning curves at low and high frequencies. J Assoc Res Otolaryngol 2013; 14:341-57. [PMID: 23423559 PMCID: PMC3642277 DOI: 10.1007/s10162-013-0373-4] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2012] [Accepted: 01/21/2013] [Indexed: 11/28/2022] Open
Abstract
Medial olivocochlear efferent neurons can control cochlear frequency selectivity and may be activated in a reflexive manner by contralateral sounds. The present study investigated the significance of the contralateral medial olivocochlear reflex (MOCR) on human psychoacoustical tuning curves (PTCs), a behavioral correlate of cochlear tuning curves. PTCs were measured using forward masking in the presence and in the absence of a contralateral white noise, assumed to elicit the MOCR. To assess MOCR effects on apical and basal cochlear regions over a wide range of sound levels, PTCs were measured for probe frequencies of 500 Hz and 4 kHz and for near- and suprathreshold conditions. Results show that the contralateral noise affected the PTCs predominantly at 500 Hz. At near-threshold levels, its effect was obvious only for frequencies in the tails of the PTCs; at suprathreshold levels, its effects were obvious for all frequencies. It was verified that the effects were not due to the contralateral noise activating the middle-ear muscle reflex or changing the postmechanical rate of recovery from forward masking. A phenomenological computer model of forward masking with efferent control was used to explain the data. The model supports the hypothesis that the behavioral results were due to the contralateral noise reducing apical cochlear gain in a frequency- and level-dependent manner consistent with physiological evidence. Altogether, this shows that the contralateral MOCR may be changing apical cochlear responses in natural, binaural listening situations.
Collapse
Affiliation(s)
- Enzo Aguilar
- />Instituto de Neurociencias de Castilla y León and Instituto de Investigaciones Biomédicas de Salamanca, Universidad de Salamanca, Calle Pintor Fernando Gallego 1, 37007 Salamanca, Spain
| | - Almudena Eustaquio-Martin
- />Instituto de Neurociencias de Castilla y León and Instituto de Investigaciones Biomédicas de Salamanca, Universidad de Salamanca, Calle Pintor Fernando Gallego 1, 37007 Salamanca, Spain
| | - Enrique A. Lopez-Poveda
- />Instituto de Neurociencias de Castilla y León and Instituto de Investigaciones Biomédicas de Salamanca, Universidad de Salamanca, Calle Pintor Fernando Gallego 1, 37007 Salamanca, Spain
- />Departamento de Cirugía, Facultad de Medicina, Universidad de Salamanca, 37007 Salamanca, Spain
| |
Collapse
|
36
|
Jennings SG, Strickland EA. Auditory filter tuning inferred with short sinusoidal and notched-noise maskers. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:2497-513. [PMID: 23039444 PMCID: PMC3477189 DOI: 10.1121/1.4746029] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2011] [Revised: 07/18/2012] [Accepted: 07/24/2012] [Indexed: 05/29/2023]
Abstract
The physiology of the medial olivocochlear reflex suggests that a sufficiently long stimulus (>100 ms) may reduce cochlear gain and result in broadened frequency selectivity. The current study attempted to avoid gain reduction by using short maskers (20 ms) to measure psychophysical tuning curves (PTCs) and notched-noise tuning characteristics, with a 4-kHz signal. The influence of off-frequency listening on PTCs was evaluated using two types of background noise. Iso-level curves were derived using an estimate of the cochlear input/output (I/O) function, which was obtained using an off-frequency masker as a linear reference. The influence of masker duration on PTCs was assessed using a model that assumed long maskers (>20 ms) evoked gain reduction. The results suggested that the off-frequency masker was a valid linear reference when deriving I/O functions and that off-frequency listening may have occurred in auditory filters apical to the signal place. The iso-level curves from this growth-of-masking study were consistent with those from a temporal-masking-curve study by Eustaquio-Martin and Lopez-Poveda [J. Assoc. Res. Otolaryngol. 12, 281-299. (2011)], suggesting that either approach may be used to derive iso-level curves. Finally, model simulations suggested that masker duration may not influence estimates of frequency selectivity.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA.
| | | |
Collapse
|