1
|
Fokam J, Takou D, Semengue ENJ, Molimbou E, Chenwi Ambe C, Durand Nka A, Ndjeyep SD, Beloumou GA, Ka'e CA, Gouissi Anguechia DH, Mundo Nayang AR, Moko Fotso LG, Kengni Ngueko AM, Etame NK, Tueguem PP, Tommo Tchouaket CM, Fainguem N, Abega Abega C, Abba A, Tambe Ayuk Ngwese D, Djubgang Djoukwe R, Akenji B, Okomo Assoumou MC, Mandeng N, Esso L, Cappelli G, Shang J, Ndongmo C, Etoundi Mballa GA, Ndembi N, Colizzi V, Perno CF, Ndjolo A. Performance characteristics of INDICAID antigen rapid diagnostic test on SARS-CoV-2 samples during the omicron wave in Cameroon. Heliyon 2024; 10:e29937. [PMID: 38694118 PMCID: PMC11058880 DOI: 10.1016/j.heliyon.2024.e29937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 02/20/2024] [Accepted: 04/17/2024] [Indexed: 05/03/2024] Open
Abstract
Background WHO recommends the use of COVID-19 antigen rapid diagnostic tests (Ag-RDT) with at least 80 % sensitivity and 97 % specificity. In the era of Omicron variants, we sought to ascertain the performance of the INDICAID™ Ag-RDT compared to real-time PCR (RT-PCR) as the gold standard. Methods A laboratory-based study was conducted among consenting individuals tested for COVID-19 at the virology laboratory of the Chantal BIYA International Reference Centre, Yaoundé-Cameron. The samples were processed by INDICAID™ Ag-RDT and DaAn Gene real-time PCR according to the manufacturer's instructions, and PCR-results were interpreted as per cycle thresholds (CT). The sensitivity, specificity, positive and negative predictive values (PPV and NVP) of INDICAID™ Ag-RDT were evaluated according to PCR CT-values. Results A total of 565 nasopharyngeal swabs were collected from participants (median age [IQR]: 40 [31-75]; M/F sex-ratio was 1.2 and 380 were vaccinated). Following PCR, overall COVID-19 positivity was 5.66 %. For CT < 37, INDICAID™ Ag-RDT sensitivity was 21.9 % (95%CI: [8.3-39.9]), specificity 100 % (95%CI: [99.3-100]); PPV 100 % (95%CI: [59.0-100]), NPV 95.5 % (95%CI: [93.4-97.1]) and kappa = 0.34 (95%CI: [0.19-0.35]). For CT < 25, sensitivity was 100 % (95%CI: [47.8-100.0]), specificity 99.6 % (95%CI: [98.7-99.9]); PPV 94.4 % (95%CI: [51.7-100]), NPV 100 % (95%CI: [99.3-100]) and kappa = 0.83 (95%CI: [0.6-1.0]). COVID-19 sequences generated were all Omicron BA.1 subvariants. Conclusion For patients infected with high viral loads (CT < 25), INDICAID™ Ag-RDT has high intrinsic (sensitivity and specificity) and extrinsic (predictive values) performances for COVID-19 diagnosis. Due to its simplicity and short turnaround time, INDICAID™ Ag-RDT is, therefore a reliable tool to prevent the spread of COVID-19 at community level in the current era of Omicron subvariants.
Collapse
Affiliation(s)
- Joseph Fokam
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Faculty of Health Sciences, University of Buea, Buea, Cameroon
- National Public Health Emergency Operations Coordination Centre, Ministry of Public Health, Yaoundé, Cameroon
- Faculty of Medicine and Biomedical Sciences, University of Yaoundé I, Yaoundé, Cameroon
| | - Désiré Takou
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
| | | | - Evariste Molimbou
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Department of Experimental Medicine, Faculty of Medicine and Surgery, University of Rome “Tor Vergata”, Rome, Italy
- Faculty of Science and Technology, Evangelic University of Cameroon, Bandjoun, Cameroon
| | - Collins Chenwi Ambe
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Department of Experimental Medicine, Faculty of Medicine and Surgery, University of Rome “Tor Vergata”, Rome, Italy
| | - Alex Durand Nka
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
| | - Sandrine Djupsa Ndjeyep
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
| | - Grace Angong Beloumou
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
| | - Christelle Aude Ka'e
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Department of Experimental Medicine, Faculty of Medicine and Surgery, University of Rome “Tor Vergata”, Rome, Italy
| | - Davy-Hyacinthe Gouissi Anguechia
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Faculty of Medicine and Biomedical Sciences, University of Yaoundé I, Yaoundé, Cameroon
| | - Audrey Rachel Mundo Nayang
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
| | - Larissa Gaëlle Moko Fotso
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Faculty of Medicine and Biomedical Sciences, University of Yaoundé I, Yaoundé, Cameroon
| | - Aurelie Minelle Kengni Ngueko
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Department of Experimental Medicine, Faculty of Medicine and Surgery, University of Rome “Tor Vergata”, Rome, Italy
| | - Naomi-Karell Etame
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Faculty of Medicine and Biomedical Sciences, University of Yaoundé I, Yaoundé, Cameroon
| | - Pamela Patricia Tueguem
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
| | - Carlos Michel Tommo Tchouaket
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- School of Health Sciences, Catholic University of Central Africa, Yaoundé, Cameroon
| | - Nadine Fainguem
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
| | - Cyrille Abega Abega
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
| | - Aissatou Abba
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Laboratory Department, Garoua Regional Health Centre, Garoua, Cameroon
| | - Derrick Tambe Ayuk Ngwese
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Faculty of Medicine and Biomedical Sciences, University of Yaoundé I, Yaoundé, Cameroon
| | - Rina Djubgang Djoukwe
- Directorate for Pharmacy, Drug and Laboratory, Ministry of Public Health, Yaounde, Cameroon
| | - Blaise Akenji
- National Public Health Laboratory, Yaoundé, Cameroon
| | - Marie-Claire Okomo Assoumou
- Faculty of Medicine and Biomedical Sciences, University of Yaoundé I, Yaoundé, Cameroon
- National Public Health Laboratory, Yaoundé, Cameroon
| | - Nadia Mandeng
- National Public Health Emergency Operations Coordination Centre, Ministry of Public Health, Yaoundé, Cameroon
- Faculty of Health Sciences, University of Bamenda, Bamenda, Cameroon
- Department of Disease, Epidemic and Pandemic Control, Ministry of Public Health, Yaounde, Cameroon
| | - Linda Esso
- National Public Health Emergency Operations Coordination Centre, Ministry of Public Health, Yaoundé, Cameroon
- Department of Disease, Epidemic and Pandemic Control, Ministry of Public Health, Yaounde, Cameroon
| | - Giulia Cappelli
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- National Research Council, Rome, Italy
| | - Judith Shang
- United States Centres for Disease Control and Prevention, Country Office, Yaoundé, Cameroon
| | - Clement Ndongmo
- United States Centres for Disease Control and Prevention, Country Office, Yaoundé, Cameroon
| | - Georges Alain Etoundi Mballa
- National Public Health Emergency Operations Coordination Centre, Ministry of Public Health, Yaoundé, Cameroon
- Department of Disease, Epidemic and Pandemic Control, Ministry of Public Health, Yaounde, Cameroon
| | - Nicaise Ndembi
- Africa Centres for Disease Control and Prevention (Africa CDC), Addis Ababa, Ethiopia
| | - Vittorio Colizzi
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Department of Experimental Medicine, Faculty of Medicine and Surgery, University of Rome “Tor Vergata”, Rome, Italy
- Faculty of Science and Technology, Evangelic University of Cameroon, Bandjoun, Cameroon
| | | | - Alexis Ndjolo
- Chantal BIYA International Reference Centre for Research on HIV/AIDS Prevention and Management, Yaoundé, Cameroon
- Faculty of Medicine and Biomedical Sciences, University of Yaoundé I, Yaoundé, Cameroon
| |
Collapse
|
2
|
Manten K, Katzenschlager S, Brümmer LE, Schmitz S, Gaeddert M, Erdmann C, Grilli M, Pollock NR, Macé A, Erkosar B, Carmona S, Ongarello S, Johnson CC, Sacks JA, Faehling V, Bornemann L, Weigand MA, Denkinger CM, Yerlikaya S. Clinical accuracy of instrument-based SARS-CoV-2 antigen diagnostic tests: a systematic review and meta-analysis. Virol J 2024; 21:99. [PMID: 38685117 PMCID: PMC11059670 DOI: 10.1186/s12985-024-02371-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Accepted: 04/17/2024] [Indexed: 05/02/2024] Open
Abstract
BACKGROUND During the COVID-19 pandemic, antigen diagnostic tests were frequently used for screening, triage, and diagnosis. Novel instrument-based antigen tests (iAg tests) hold the promise of outperforming their instrument-free, visually-read counterparts. Here, we provide a systematic review and meta-analysis of the SARS-CoV-2 iAg tests' clinical accuracy. METHODS We systematically searched MEDLINE (via PubMed), Web of Science, medRxiv, and bioRxiv for articles published before November 7th, 2022, evaluating the accuracy of iAg tests for SARS-CoV-2 detection. We performed a random effects meta-analysis to estimate sensitivity and specificity and used the QUADAS-2 tool to assess study quality and risk of bias. Sub-group analysis was conducted based on Ct value range, IFU-conformity, age, symptom presence and duration, and the variant of concern. RESULTS We screened the titles and abstracts of 20,431 articles and included 114 publications that fulfilled the inclusion criteria. Additionally, we incorporated three articles sourced from the FIND website, totaling 117 studies encompassing 95,181 individuals, which evaluated the clinical accuracy of 24 commercial COVID-19 iAg tests. The studies varied in risk of bias but showed high applicability. Of 24 iAg tests from 99 studies assessed in the meta-analysis, the pooled sensitivity and specificity compared to molecular testing of a paired NP swab sample were 76.7% (95% CI 73.5 to 79.7) and 98.4% (95% CI 98.0 to 98.7), respectively. Higher sensitivity was noted in individuals with high viral load (99.6% [95% CI 96.8 to 100] at Ct-level ≤ 20) and within the first week of symptom onset (84.6% [95% CI 78.2 to 89.3]), but did not differ between tests conducted as per manufacturer's instructions and those conducted differently, or between point-of-care and lab-based testing. CONCLUSION Overall, iAg tests have a high pooled specificity but a moderate pooled sensitivity, according to our analysis. The pooled sensitivity increases with lower Ct-values (a proxy for viral load), or within the first week of symptom onset, enabling reliable identification of most COVID-19 cases and highlighting the importance of context in test selection. The study underscores the need for careful evaluation considering performance variations and operational features of iAg tests.
Collapse
Affiliation(s)
- Katharina Manten
- Department of Infectious Disease and Tropical Medicine, Heidelberg University Hospital, Im Neuenheimer Feld 324, 69120, Heidelberg, Germany
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Stephan Katzenschlager
- Department of Infectious Disease and Tropical Medicine, Heidelberg University Hospital, Im Neuenheimer Feld 324, 69120, Heidelberg, Germany
| | - Lukas E Brümmer
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Stephani Schmitz
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
- Department of Developmental Biology, Erasmus Medical Center, Rotterdam, Netherlands
| | - Mary Gaeddert
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Maurizio Grilli
- Library, University Medical Center Mannheim, Mannheim, Germany
| | - Nira R Pollock
- Department of Laboratory Medicine, Boston Children's Hospital, Boston, MA, USA
| | | | | | | | | | - Cheryl C Johnson
- Global HIV, Hepatitis and STIs Programmes, World Health Organization, Geneva, Switzerland
| | - Jilian A Sacks
- Department of Epidemic and Pandemic Preparedness and Prevention, World Health Organization, Geneva, Switzerland
| | - Verena Faehling
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Linus Bornemann
- Institute of Virology, Faculty of Medicine, University Medical Centre, University of Freiburg, Freiburg, Germany
| | - Markus A Weigand
- Department of Infectious Disease and Tropical Medicine, Heidelberg University Hospital, Im Neuenheimer Feld 324, 69120, Heidelberg, Germany
| | - Claudia M Denkinger
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
- German Center for Infection Research (DZIF), partner site Heidelberg University Hospital, Heidelberg, Germany
| | - Seda Yerlikaya
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany.
- German Center for Infection Research (DZIF), partner site Heidelberg University Hospital, Heidelberg, Germany.
| |
Collapse
|
3
|
Osterman A, Krenn F, Iglhaut M, Badell I, Lehner A, Späth PM, Stern M, Both H, Bender S, Muenchhoff M, Graf A, Krebs S, Blum H, Grimmer T, Durner J, Czibere L, Dächert C, Grzimek-Koschewa N, Protzer U, Kaderali L, Baldauf HM, Keppler OT. Automated antigen assays display a high heterogeneity for the detection of SARS-CoV-2 variants of concern, including several Omicron sublineages. Med Microbiol Immunol 2023; 212:307-322. [PMID: 37561226 PMCID: PMC10501957 DOI: 10.1007/s00430-023-00774-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 07/11/2023] [Indexed: 08/11/2023]
Abstract
Diagnostic tests for direct pathogen detection have been instrumental to contain the severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) pandemic. Automated, quantitative, laboratory-based nucleocapsid antigen (Ag) tests for SARS-CoV-2 have been launched alongside nucleic acid-based test systems and point-of-care (POC) lateral-flow Ag tests. Here, we evaluated four commercial Ag tests on automated platforms for the detection of different sublineages of the SARS-CoV-2 Omicron variant of concern (VoC) (B.1.1.529) in comparison with "non-Omicron" VoCs. A total of 203 Omicron PCR-positive respiratory swabs (53 BA.1, 48 BA.2, 23 BQ.1, 39 XBB.1.5 and 40 other subvariants) from the period February to March 2022 and from March 2023 were examined. In addition, tissue culture-expanded clinical isolates of Delta (B.1.617.2), Omicron-BA.1, -BF.7, -BN.1 and -BQ.1 were studied. These results were compared to previously reported data from 107 clinical "non-Omicron" samples from the end of the second pandemic wave (February to March 2021) as well as cell culture-derived samples of wildtype (wt) EU-1 (B.1.177), Alpha VoC (B.1.1.7) and Beta VoC (B.1.351)). All four commercial Ag tests were able to detect at least 90.9% of Omicron-containing samples with high viral loads (Ct < 25). The rates of true-positive test results for BA.1/BA.2-positive samples with intermediate viral loads (Ct 25-30) ranged between 6.7% and 100.0%, while they dropped to 0 to 15.4% for samples with low Ct values (> 30). This heterogeneity was reflected also by the tests' 50%-limit of detection (LoD50) values ranging from 44,444 to 1,866,900 Geq/ml. Respiratory samples containing Omicron-BQ.1/XBB.1.5 or other Omicron subvariants that emerged in 2023 were detected with enormous heterogeneity (0 to 100%) for the intermediate and low viral load ranges with LoD50 values between 23,019 and 1,152,048 Geq/ml. In contrast, detection of "non-Omicron" samples was more sensitive, scoring positive in 35 to 100% for the intermediate and 1.3 to 32.9% of cases for the low viral loads, respectively, corresponding to LoD50 values ranging from 6181 to 749,792 Geq/ml. All four assays detected cell culture-expanded VoCs Alpha, Beta, Delta and Omicron subvariants carrying up to six amino acid mutations in the nucleocapsid protein with sensitivities comparable to the non-VoC EU-1. Overall, automated quantitative SARS-CoV-2 Ag assays are not more sensitive than standard rapid antigen tests used in POC settings and show a high heterogeneity in performance for VoC recognition. The best of these automated Ag tests may have the potential to complement nucleic acid-based assays for SARS-CoV-2 diagnostics in settings not primarily focused on the protection of vulnerable groups. In light of the constant emergence of new Omicron subvariants and recombinants, most recently the XBB lineage, these tests' performance must be regularly re-evaluated, especially when new VoCs carry mutations in the nucleocapsid protein or immunological and clinical parameters change.
Collapse
Affiliation(s)
- Andreas Osterman
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Franziska Krenn
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Maximilian Iglhaut
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Irina Badell
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Andreas Lehner
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Patricia M Späth
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Marcel Stern
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Hanna Both
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Sabine Bender
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Maximilian Muenchhoff
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
- German Center for Infection Research (DZIF), Partner Site, Munich, Germany
- COVID‑19 Registry of the LMU Munich (CORKUM), University Hospital, LMU München, Munich, Germany
| | - Alexander Graf
- Laboratory for Functional Genome Analysis, Gene Center, LMU München, Munich, Germany
| | - Stefan Krebs
- Laboratory for Functional Genome Analysis, Gene Center, LMU München, Munich, Germany
| | - Helmut Blum
- Laboratory for Functional Genome Analysis, Gene Center, LMU München, Munich, Germany
| | - Timo Grimmer
- Department of Psychiatry and Psychotherapy, Klinikum Rechts der Isar, School of Medicine, Technical University of Munich, Munich, Germany
| | - Jürgen Durner
- Labor Becker MVZ GbR, Munich, Germany
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU München, Munich, Germany
| | | | - Christopher Dächert
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Natascha Grzimek-Koschewa
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
- German Center for Infection Research (DZIF), Partner Site, Munich, Germany
| | - Ulrike Protzer
- German Center for Infection Research (DZIF), Partner Site, Munich, Germany
- Institute of Virology, Technical University of Munich/Helmholtz Zentrum München, Munich, Germany
| | - Lars Kaderali
- Institute of Bioinformatics, University Medicine Greifswald, Greifswald, Germany
| | - Hanna-Mari Baldauf
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany.
| | - Oliver T Keppler
- Max von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany.
- German Center for Infection Research (DZIF), Partner Site, Munich, Germany.
- COVID‑19 Registry of the LMU Munich (CORKUM), University Hospital, LMU München, Munich, Germany.
| |
Collapse
|
4
|
Juniastuti, Furqoni AH, Amin M, Restifan YD, Putri SMD, Ferandra VA, Lusida MI. The evaluation results of proposed antigen rapid diagnostic tests for COVID-19: some possible factors might influence. Infection 2023; 51:1285-1291. [PMID: 36592297 PMCID: PMC9806449 DOI: 10.1007/s15010-022-01975-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 12/22/2022] [Indexed: 01/03/2023]
Abstract
PURPOSE In addition to existing gold standard qRT-PCR methods, there is a need to develop reliable rapid tests for infection control with early notification of COVID-19 cases to enable effective outbreak management. We evaluated the validity of the three Ag-RDT kits proposed by some companies in different countries by using qRT-PCR and analyzed its results. METHODS Each of the three Ag-RDT kits (namely A, B, and C) was tested with 90 samples, consisting of samples with Ct ≤ 25, samples with Ct > 25, and negative SARS-CoV-2 PCR samples. RESULTS This study showed that for samples with Ct > 25, all the three kits could not detect SARS-CoV-2 Ag (0% sensitivity) but showed 100% specificity. Meanwhile, for samples with Ct ≤ 25, kit C was the best (76.7% sensitivity and 100% specificity). The PPV of the three kits was 100%, but their NPV ranged 63-84.8%. Kit C showed the best accuracy (89.9%). Some factors might influence the results of evaluation, such as variation of virus proteins and transportation-storage of the kits. CONCLUSION The overall specificity of the three kits for all samples was high; however, all of them have not met the minimum performance requirements of ≥ 80% sensitivity for samples with Ct ≤ 25. The validation test is much necessary to be carried out by the authority in national health care to ensure the feasibility of the kit for point-of-care testing (POCT) of COVID-19. Some factors that might influence should be anticipated to increase their sensitivities and specificities.
Collapse
Affiliation(s)
- Juniastuti
- Department of Medical Microbiology, Faculty of Medicine, Universitas Airlangga, Surabaya, East Java, Indonesia
- Clinical Microbiology Residency Program, Faculty of Medicine, Universitas Airlangga - Dr. Soetomo General Hospital, Surabaya, Indonesia
- Institute of Tropical Disease, Universitas Airlangga, Campus C Jalan Mulyorejo, Surabaya, East Java, Indonesia
| | - Abdul Hadi Furqoni
- Institute of Tropical Disease, Universitas Airlangga, Campus C Jalan Mulyorejo, Surabaya, East Java, Indonesia
| | - Mochamad Amin
- Institute of Tropical Disease, Universitas Airlangga, Campus C Jalan Mulyorejo, Surabaya, East Java, Indonesia
| | - Yanna Debby Restifan
- Institute of Tropical Disease, Universitas Airlangga, Campus C Jalan Mulyorejo, Surabaya, East Java, Indonesia
| | - Serius Miliyani Dwi Putri
- Institute of Tropical Disease, Universitas Airlangga, Campus C Jalan Mulyorejo, Surabaya, East Java, Indonesia
| | - Virginia Ayu Ferandra
- Institute of Tropical Disease, Universitas Airlangga, Campus C Jalan Mulyorejo, Surabaya, East Java, Indonesia
| | - Maria Inge Lusida
- Department of Medical Microbiology, Faculty of Medicine, Universitas Airlangga, Surabaya, East Java, Indonesia.
- Clinical Microbiology Residency Program, Faculty of Medicine, Universitas Airlangga - Dr. Soetomo General Hospital, Surabaya, Indonesia.
- Institute of Tropical Disease, Universitas Airlangga, Campus C Jalan Mulyorejo, Surabaya, East Java, Indonesia.
| |
Collapse
|
5
|
Yang YP, Jiesisibieke ZL, Tung TH. Association Between Rapid Antigen Detection Tests and Real-Time Reverse Transcription-Polymerase Chain Reaction Assay for SARS-CoV-2: A Systematic Review and Meta-Analyses. Int J Public Health 2023; 68:1605452. [PMID: 37588042 PMCID: PMC10425602 DOI: 10.3389/ijph.2023.1605452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Accepted: 07/11/2023] [Indexed: 08/18/2023] Open
Abstract
Objectives: We aimed to assess the association between rapid antigen detection tests and real-time reverse transcription-polymerase chain reaction assay for severe acute respiratory syndrome coronavirus 2. Methods: We searched PubMed, Cochrane Library, EMBASE, and the Web of Science from their inception to 31 May 2023. A random-effects meta-analysis was used to estimate false positives in the RADTs group, relative to those in the RT-PCR group, and subgroup analyses were conducted based on the different Ct value cut-offs (<40 or ≥40). We performed this study in accordance with the guidelines outlined in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Results: Fifty-one studies were included and considered to be of moderate quality. We found a satisfactory overall false positive rate (0.01, 95% CI: 0.00-0.01) for the RADTs compared to RT-PCR. In the stratified analysis, we also found that the false positive rates of the RADTs did not increase when Ct values of RT-PCR (Ct < 40, 0.01, 95% CI: 0.00-0.01; Ct ≥ 40, 0.01, 95% CI: 0.00-0.01). Conclusion: In conclusion, the best available evidence supports an association between RADTs and RT-PCR. When Ct-values were analyzed using cut-off <40 or ≥40, this resulted in an estimated false positive rate of only 1%.
Collapse
Affiliation(s)
- Yu-Pei Yang
- Department of Hematology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Linhai, Zhejiang, China
| | - Zhu Liduzi Jiesisibieke
- School of Public Health, The University of Hong Kong Li Ka Shing Faculty of Medicine, Pokfulam, Hong Kong, Hong Kong SAR, China
| | - Tao-Hsin Tung
- Evidence-Based Medicine Center, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Linhai, Zhejiang, China
| |
Collapse
|
6
|
Arici N, Kansak N, Şentürk T, Baydili K, Aksaray S. Comparison of performance of LIAISON SARS-CoV-2 antigen assay with RT-PCR during the Omicron wave. Acta Microbiol Immunol Hung 2023; 70:1-6. [PMID: 36622645 DOI: 10.1556/030.2022.01863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 12/22/2022] [Indexed: 01/10/2023]
Abstract
Due to the newly emerging Omicron variant, there is a need to re-evaluate the performance of automated antigen tests. Our study aim was to evaluate the performance of the automated Liaison SARS-CoV-2 antigen assay against reverse transcriptase polymerase chain reaction (RT-PCR) in samples with Omicron variant.A prospective study was performed on 373 combined oro-nasopharyngeal samples (NPS) randomly collected from symptomatic patients. NPS were tested with Liaison SARS-CoV-2 Ag test (DiaSorin, Italy) and DS Coronex COVID-19 Multiplex RT-PCR Diagnosis Kit (DS BioTechnology, Ankara, Turkey).Of 373 samples, 124 (33.2%) were found to be RT-PCR positive and 249 (66.8%) RT-PCR negative. Taking RT-PCR as a reference, the sensitivity and specificity of the Liaison SARS-CoV-2 Ag assay were found as 84.6% (95%CI 77.3%-90%) and 100% (95%CI 98.5%-100%), respectively. For samples with a cycle threshold (Ct) value <25 (high viral load), the sensitivity increased to 100%. When antigen concentration and Ct values were compared, a strong negative correlation between antigen and Ct values was determined (P < 0.001).The Liaison antigen test met the performance criteria recommended by the WHO for samples with the Omicron variant. In addition, it showed excellent sensitivity and specificity in patients with high viral load. Therefore, Liaison antigen test can be a reliable and useful alternative in the diagnosis of SARS-CoV-2 infection, particularly in resource-constrained laboratories.
Collapse
Affiliation(s)
- Neslihan Arici
- 1University of Health Sciences, Haydarpasa Research and Training Hospital, Medical Microbiology Laboratory, Istanbul, Turkey
| | - Nilgün Kansak
- 1University of Health Sciences, Haydarpasa Research and Training Hospital, Medical Microbiology Laboratory, Istanbul, Turkey
| | - Tuğçe Şentürk
- 2Istanbul University, Faculty of Science, Department of Molecular Biology and Genetics, Istanbul, Turkey
| | - Kürşat Baydili
- 3University of Health Sciences, Faculty of Medicine Hamidiye, Department of Bioistatistic and Medical Informatic, Istanbul, Turkey
| | - Sebahat Aksaray
- 4University of Health Sciences, Faculty of Medicine Hamidiye, Department of Medical Microbiology, Istanbul, Turkey
| |
Collapse
|
7
|
Gokool VA, Crespo-Cajigas J, Mallikarjun A, Collins A, Kane SA, Plymouth V, Nguyen E, Abella BS, Holness HK, Furton KG, Johnson ATC, Otto CM. The Use of Biological Sensors and Instrumental Analysis to Discriminate COVID-19 Odor Signatures. BIOSENSORS 2022; 12:1003. [PMID: 36421122 PMCID: PMC9688190 DOI: 10.3390/bios12111003] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 11/01/2022] [Accepted: 11/08/2022] [Indexed: 05/27/2023]
Abstract
The spread of SARS-CoV-2, which causes the disease COVID-19, is difficult to control as some positive individuals, capable of transmitting the disease, can be asymptomatic. Thus, it remains critical to generate noninvasive, inexpensive COVID-19 screening systems. Two such methods include detection canines and analytical instrumentation, both of which detect volatile organic compounds associated with SARS-CoV-2. In this study, the performance of trained detection dogs is compared to a noninvasive headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) approach to identifying COVID-19 positive individuals. Five dogs were trained to detect the odor signature associated with COVID-19. They varied in performance, with the two highest-performing dogs averaging 88% sensitivity and 95% specificity over five double-blind tests. The three lowest-performing dogs averaged 46% sensitivity and 87% specificity. The optimized linear discriminant analysis (LDA) model, developed using HS-SPME-GC-MS, displayed a 100% true positive rate and a 100% true negative rate using leave-one-out cross-validation. However, the non-optimized LDA model displayed difficulty in categorizing animal hair-contaminated samples, while animal hair did not impact the dogs' performance. In conclusion, the HS-SPME-GC-MS approach for noninvasive COVID-19 detection more accurately discriminated between COVID-19 positive and COVID-19 negative samples; however, dogs performed better than the computational model when non-ideal samples were presented.
Collapse
Affiliation(s)
- Vidia A. Gokool
- Global Forensic and Justice Center, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
| | - Janet Crespo-Cajigas
- Global Forensic and Justice Center, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
| | - Amritha Mallikarjun
- Penn Vet Working Dog Center, Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Amanda Collins
- Penn Vet Working Dog Center, Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Sarah A. Kane
- Penn Vet Working Dog Center, Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Victoria Plymouth
- Penn Vet Working Dog Center, Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Elizabeth Nguyen
- Penn Vet Working Dog Center, Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Benjamin S. Abella
- Department of Emergency Medicine and Penn Acute Research Collaboration, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Howard K. Holness
- Global Forensic and Justice Center, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
| | - Kenneth G. Furton
- Global Forensic and Justice Center, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
| | - Alan T. Charlie Johnson
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Cynthia M. Otto
- Penn Vet Working Dog Center, Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
8
|
Gunell M, Rantasärkkä K, Arjonen R, Sandén A, Vuorinen T. Clinical evaluation of an automated, rapid mariPOC antigen test in screening of symptomatics and asymptomatics for SARS-CoV-2 infection. J Med Virol 2022; 95:e28189. [PMID: 36177677 PMCID: PMC9538064 DOI: 10.1002/jmv.28189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 09/21/2022] [Accepted: 09/27/2022] [Indexed: 01/11/2023]
Abstract
A novel automated mariPOC SARS-CoV-2 antigen test was evaluated in a Health Care Center Laboratory among symptomatic and asymptomatic individuals seeking SARS-CoV-2 testing. According to the national testing strategy, reverse transcription polymerase chain reaction (RT-PCR) was used as a reference method. A total of 962 subjects were included in this study, 4.8% (46/962) of their samples were SARS-CoV-2 RT-PCR-positive, and 87% (40/46) of these were from symptomatics. Among the symptomatics, the overall sensitivity of the mariPOC SARS-CoV-2 test was 82.5% (33/40), though the sensitivity increased to 97.1% (33/34) in samples with a Ct < 30. The mariPOC SARS-CoV-2 test detected two of six PCR-positive samples among the asymptomatics, four cases that remained antigen test negative had Ct values between 28 and 36. The specificity of the mariPOC SARS-CoV-2 test was 100% (916/916). The evaluation showed that the mariPOC SARS-CoV-2 rapid antigen test is very sensitive and specific for the detection of individuals who most probably are contagious.
Collapse
Affiliation(s)
- Marianne Gunell
- Clinical Microbiology, Laboratory DivisionTurku University HospitalTurkuFinland,Institute of BiomedicineUniversity of TurkuTurkuFinland
| | - Kaisa Rantasärkkä
- Clinical Microbiology, Laboratory DivisionTurku University HospitalTurkuFinland
| | | | | | - Tytti Vuorinen
- Clinical Microbiology, Laboratory DivisionTurku University HospitalTurkuFinland,Institute of BiomedicineUniversity of TurkuTurkuFinland
| |
Collapse
|
9
|
Lippi G, Henry BM, Plebani M, Adeli K. Systematic Review of Diagnostic Accuracy of DiaSorin Liaison SARS-CoV-2 Antigen Immunoassay. EJIFCC 2022; 33:94-104. [PMID: 36313904 PMCID: PMC9562478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Background Quantification of SARS-CoV-2 antigens by means of rapid, high-throughput and fully-automated techniques has been proposed as a feasible alternative to overcome the current shortage of resources for routine molecular diagnostics. To this end, we provide here a systematic review of diagnostic accuracy of DiaSorin Liaison SARS-CoV-2 antigen immunoassay. Methods An electronic search was conduced in Medline and Scopus, with no language or date restrictions (up to January 20, 2022), for identifying all published studies articles in which the diagnostic performance of the DiaSorin Liaison SARS-CoV-2 antigen immunoassay was compared with molecular diagnostic techniques. Results The electronic search identified a final number of 11 studies, totalling 4449 oro- and naso-pharyngeal specimens. The pooled diagnostic sensitivity, specificity and area under the curve (AUC) of the Liaison SARS-CoV-2 antigen immunoassay in all samples were 0.51 (95%CI, 0.49-0.54), 1.00 (95%CI, 1.00-1.00) and 0.994 (95%CI, 0.990-0.998), respectively, whilst the overall concordance with molecular diagnostics was 82.1%. The pooled diagnostic sensitivity, specificity and AUC of the Liaison SARS-CoV-2 antigen immunoassay in specimens with high viral load (i.e., cycle threshold values <25-30) were 0.79 (95%CI, 0.75-0.82), 1.00 (95%CI, 0.99-1.00) and 0.911 (95%CI, 0.879-0.943), respectively, whilst the overall concordance with molecular diagnostics in such samples increased to 94.2%. Conclusion The results of this systematic literature review suggest that there is sufficient accuracy of the DiaSorin Liaison SARS-CoV-2 antigen immunoassay in samples with high viral loads that would enable its reliable usage for identifying superspreaders, who are responsible for the vast majority of transmission events.
Collapse
Affiliation(s)
- Giuseppe Lippi
- IFCC Task Force on COVID-19, Milano, Italy, Section of Clinical Biochemistry, University of Verona, Verona, Italy,Corresponding author: Prof. Giuseppe Lippi Section of Clinical Biochemistry University Hospital of Verona Piazzale L.A. Scuro, 10 37134 Verona Italy Phone: 0039-045-8122970 Fax: 0039-045-8124308 E-mail:
| | - Brandon M. Henry
- IFCC Task Force on COVID-19, Milano, Italy, Clinical Laboratory, Division of Nephrology and Hypertension, Cincinnati Children’s Hospital Medical Center, Cincinnati OH, USA, Disease Intervention & Prevention and Population Health Programs, Texas Biomedical Research Institute, San Antonio, Texas, USA
| | | | - Khosrow Adeli
- IFCC Task Force on COVID-19, Milano, Italy, Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
10
|
Dinnes J, Sharma P, Berhane S, van Wyk SS, Nyaaba N, Domen J, Taylor M, Cunningham J, Davenport C, Dittrich S, Emperador D, Hooft L, Leeflang MM, McInnes MD, Spijker R, Verbakel JY, Takwoingi Y, Taylor-Phillips S, Van den Bruel A, Deeks JJ. Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection. Cochrane Database Syst Rev 2022; 7:CD013705. [PMID: 35866452 PMCID: PMC9305720 DOI: 10.1002/14651858.cd013705.pub3] [Citation(s) in RCA: 65] [Impact Index Per Article: 32.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Accurate rapid diagnostic tests for SARS-CoV-2 infection would be a useful tool to help manage the COVID-19 pandemic. Testing strategies that use rapid antigen tests to detect current infection have the potential to increase access to testing, speed detection of infection, and inform clinical and public health management decisions to reduce transmission. This is the second update of this review, which was first published in 2020. OBJECTIVES To assess the diagnostic accuracy of rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection. We consider accuracy separately in symptomatic and asymptomatic population groups. Sources of heterogeneity investigated included setting and indication for testing, assay format, sample site, viral load, age, timing of test, and study design. SEARCH METHODS We searched the COVID-19 Open Access Project living evidence database from the University of Bern (which includes daily updates from PubMed and Embase and preprints from medRxiv and bioRxiv) on 08 March 2021. We included independent evaluations from national reference laboratories, FIND and the Diagnostics Global Health website. We did not apply language restrictions. SELECTION CRITERIA We included studies of people with either suspected SARS-CoV-2 infection, known SARS-CoV-2 infection or known absence of infection, or those who were being screened for infection. We included test accuracy studies of any design that evaluated commercially produced, rapid antigen tests. We included evaluations of single applications of a test (one test result reported per person) and evaluations of serial testing (repeated antigen testing over time). Reference standards for presence or absence of infection were any laboratory-based molecular test (primarily reverse transcription polymerase chain reaction (RT-PCR)) or pre-pandemic respiratory sample. DATA COLLECTION AND ANALYSIS We used standard screening procedures with three people. Two people independently carried out quality assessment (using the QUADAS-2 tool) and extracted study results. Other study characteristics were extracted by one review author and checked by a second. We present sensitivity and specificity with 95% confidence intervals (CIs) for each test, and pooled data using the bivariate model. We investigated heterogeneity by including indicator variables in the random-effects logistic regression models. We tabulated results by test manufacturer and compliance with manufacturer instructions for use and according to symptom status. MAIN RESULTS We included 155 study cohorts (described in 166 study reports, with 24 as preprints). The main results relate to 152 evaluations of single test applications including 100,462 unique samples (16,822 with confirmed SARS-CoV-2). Studies were mainly conducted in Europe (101/152, 66%), and evaluated 49 different commercial antigen assays. Only 23 studies compared two or more brands of test. Risk of bias was high because of participant selection (40, 26%); interpretation of the index test (6, 4%); weaknesses in the reference standard for absence of infection (119, 78%); and participant flow and timing 41 (27%). Characteristics of participants (45, 30%) and index test delivery (47, 31%) differed from the way in which and in whom the test was intended to be used. Nearly all studies (91%) used a single RT-PCR result to define presence or absence of infection. The 152 studies of single test applications reported 228 evaluations of antigen tests. Estimates of sensitivity varied considerably between studies, with consistently high specificities. Average sensitivity was higher in symptomatic (73.0%, 95% CI 69.3% to 76.4%; 109 evaluations; 50,574 samples, 11,662 cases) compared to asymptomatic participants (54.7%, 95% CI 47.7% to 61.6%; 50 evaluations; 40,956 samples, 2641 cases). Average sensitivity was higher in the first week after symptom onset (80.9%, 95% CI 76.9% to 84.4%; 30 evaluations, 2408 cases) than in the second week of symptoms (53.8%, 95% CI 48.0% to 59.6%; 40 evaluations, 1119 cases). For those who were asymptomatic at the time of testing, sensitivity was higher when an epidemiological exposure to SARS-CoV-2 was suspected (64.3%, 95% CI 54.6% to 73.0%; 16 evaluations; 7677 samples, 703 cases) compared to where COVID-19 testing was reported to be widely available to anyone on presentation for testing (49.6%, 95% CI 42.1% to 57.1%; 26 evaluations; 31,904 samples, 1758 cases). Average specificity was similarly high for symptomatic (99.1%) or asymptomatic (99.7%) participants. We observed a steady decline in summary sensitivities as measures of sample viral load decreased. Sensitivity varied between brands. When tests were used according to manufacturer instructions, average sensitivities by brand ranged from 34.3% to 91.3% in symptomatic participants (20 assays with eligible data) and from 28.6% to 77.8% for asymptomatic participants (12 assays). For symptomatic participants, summary sensitivities for seven assays were 80% or more (meeting acceptable criteria set by the World Health Organization (WHO)). The WHO acceptable performance criterion of 97% specificity was met by 17 of 20 assays when tests were used according to manufacturer instructions, 12 of which demonstrated specificities above 99%. For asymptomatic participants the sensitivities of only two assays approached but did not meet WHO acceptable performance standards in one study each; specificities for asymptomatic participants were in a similar range to those observed for symptomatic people. At 5% prevalence using summary data in symptomatic people during the first week after symptom onset, the positive predictive value (PPV) of 89% means that 1 in 10 positive results will be a false positive, and around 1 in 5 cases will be missed. At 0.5% prevalence using summary data for asymptomatic people, where testing was widely available and where epidemiological exposure to COVID-19 was suspected, resulting PPVs would be 38% to 52%, meaning that between 2 in 5 and 1 in 2 positive results will be false positives, and between 1 in 2 and 1 in 3 cases will be missed. AUTHORS' CONCLUSIONS Antigen tests vary in sensitivity. In people with signs and symptoms of COVID-19, sensitivities are highest in the first week of illness when viral loads are higher. Assays that meet appropriate performance standards, such as those set by WHO, could replace laboratory-based RT-PCR when immediate decisions about patient care must be made, or where RT-PCR cannot be delivered in a timely manner. However, they are more suitable for use as triage to RT-PCR testing. The variable sensitivity of antigen tests means that people who test negative may still be infected. Many commercially available rapid antigen tests have not been evaluated in independent validation studies. Evidence for testing in asymptomatic cohorts has increased, however sensitivity is lower and there is a paucity of evidence for testing in different settings. Questions remain about the use of antigen test-based repeat testing strategies. Further research is needed to evaluate the effectiveness of screening programmes at reducing transmission of infection, whether mass screening or targeted approaches including schools, healthcare setting and traveller screening.
Collapse
Affiliation(s)
- Jacqueline Dinnes
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK
| | - Pawana Sharma
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - Sarah Berhane
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK
| | - Susanna S van Wyk
- Centre for Evidence-based Health Care, Epidemiology and Biostatistics, Department of Global Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa
| | - Nicholas Nyaaba
- Infectious Disease Unit, 37 Military Hospital, Cantonments, Ghana
| | - Julie Domen
- Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
| | - Melissa Taylor
- Department of Clinical Sciences, Liverpool School of Tropical Medicine, Liverpool, UK
| | - Jane Cunningham
- Global Malaria Programme, World Health Organization, Geneva, Switzerland
| | - Clare Davenport
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK
| | | | | | - Lotty Hooft
- Cochrane Netherlands, Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
| | - Mariska Mg Leeflang
- Department of Clinical Epidemiology, Biostatistics and Bioinformatics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, Netherlands
| | | | - René Spijker
- Cochrane Netherlands, Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
- Medical Library, Amsterdam UMC, University of Amsterdam, Amsterdam Public Health, Amsterdam, Netherlands
| | - Jan Y Verbakel
- Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
| | - Yemisi Takwoingi
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK
| | - Sian Taylor-Phillips
- Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, UK
| | - Ann Van den Bruel
- Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
| | - Jonathan J Deeks
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK
| |
Collapse
|
11
|
Diagnostic utility and performance of rapid antigen test in SARS CoV- 2 in symptomatic and asymptomatic patients during the second pandemic wave in Kashmir, North India. Indian J Med Microbiol 2022; 40:572-576. [PMID: 35787334 PMCID: PMC9249411 DOI: 10.1016/j.ijmmb.2022.06.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 06/09/2022] [Accepted: 06/16/2022] [Indexed: 11/29/2022]
Abstract
Purpose Real time reverse transcriptase PCR (rRT PCR) although gold standard test for the diagnosis of SARS CoV-2, carries disadvantages of a sophisticated set up, long time to results and centralized services. The rapid antigen tests (RAT) can be used as a primary screening tool with the advantages of rapid turnaround time and ease of use. The study was conducted to determine the performance of rapid antigen test (standard Q COVID 19 Ag) in comparison to rRT PCR in symptomatic patients and asymptomatic contacts and asymptomatic patients with no apparent contact history. Methods Nasopharyngeal swabs taken in duplicate from 1034 patients were collected over a 5 months period. These included 248 (23.98%) symptomatic, 386 (37.34%) asymptomatic contacts and 400 (38.68%) asymptomatic subjects who were routinely screened in pre-operative period, as a prerequisite for travel, or pregnant females. Both rRT PCR and RAT were performed as per manufacturers’ instructions. Performance of test in different subgroups of patients was evaluated. Performance of RAT test on basis of duration of illness and Ct values was also analyzed. Results In this study, 445 (43.04%) were rRT PCR positive, out of which 374 samples were RAT positive as well. 31 samples were RAT positive but PCR negative. The sensitivity, specificity, PPV and NPV of the rapid antigen test was 84.04%, 94.74%, 92.35% and 88.71% respectively. The negative predictive value of the test in asymptomatic patients without any significant contact history was 97.07%. Conclusions This study recommends the use of the antigen test as a method of diagnosis for SARS CoV-2. However a negative result with RAT in suspected patients and their contacts should be viewed with caution. This study also finds the utility of using RAT test in the community settings as a screening test in schools, colleges and mass gatherings.
Collapse
|
12
|
Hörber S, Drees C, Ganzenmueller T, Schmauder K, Peter S, Biskup D, Peter A. Evaluation of a laboratory-based high-throughput SARS-CoV-2 antigen assay. Clin Chem Lab Med 2022; 60:1478-1485. [PMID: 35700973 DOI: 10.1515/cclm-2022-0360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 05/31/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVES Antigen tests are an essential part of SARS-CoV-2 testing strategies. Rapid antigen tests are easy to use but less sensitive compared to nucleic acid amplification tests (NAT) and less suitable for large-scale testing. In contrast, laboratory-based antigen tests are suitable for high-throughput immunoanalyzers. Here we evaluated the diagnostic performance of the laboratory-based Siemens Healthineers SARS-CoV-2 Antigen (CoV2Ag) assay. METHODS In a public test center, from 447 individuals anterior nasal swab specimens as well as nasopharyngeal swab specimens were collected. The nasal swab specimens were collected in sample inactivation medium and measured using the CoV2Ag assay. The nasopharyngeal swab specimens were measured by RT-PCR. Additionally, 9,046 swab specimens obtained for screening purposes in a tertiary care hospital were analyzed and positive CoV2Ag results confirmed by NAT. RESULTS In total, 234/447 (52.3%) participants of the public test center were positive for SARS-CoV-2-RNA. Viral lineage B1.1.529 was dominant during the study. Sensitivity and specificity of the CoV2Ag assay were 88.5% (95%CI: 83.7-91.9%) and 99.5% (97.4-99.9%), respectively. Sensitivity increased to 93.7% (97.4-99.9%) and 98.7% (97.4-99.9%) for swab specimens with cycle threshold values <30 and <25, respectively. Out of 9,046 CoV2Ag screening tests from hospitalized patients, 21 (0.2%) swab specimens were determined as false-positive by confirmatory NAT. CONCLUSIONS Using sample tubes containing inactivation medium the laboratory-based high-throughput CoV2Ag assay is a very specific and highly sensitive assay for detection of SARS-CoV-2 antigen in nasal swab specimens including the B1.1.529 variant. In low prevalence settings confirmation of positive CoV2Ag results by SARS-CoV-2-RNA testing is recommended.
Collapse
Affiliation(s)
- Sebastian Hörber
- Institute for Clinical Chemistry and Pathobiochemistry, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| | - Christoph Drees
- Institute for Clinical Chemistry and Pathobiochemistry, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| | - Tina Ganzenmueller
- Institute of Medical Virology, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| | - Kristina Schmauder
- Institute of Medical Microbiology and Hygiene, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| | - Silke Peter
- Institute of Medical Microbiology and Hygiene, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| | | | - Andreas Peter
- Institute for Clinical Chemistry and Pathobiochemistry, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| |
Collapse
|
13
|
Tapari A, Braliou GG, Papaefthimiou M, Mavriki H, Kontou PI, Nikolopoulos GK, Bagos PG. Performance of Antigen Detection Tests for SARS-CoV-2: A Systematic Review and Meta-Analysis. Diagnostics (Basel) 2022; 12:1388. [PMID: 35741198 PMCID: PMC9221910 DOI: 10.3390/diagnostics12061388] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 05/20/2022] [Accepted: 05/24/2022] [Indexed: 11/16/2022] Open
Abstract
Coronavirus disease 2019 (COVID-19) initiated global health care challenges such as the necessity for new diagnostic tests. Diagnosis by real-time PCR remains the gold-standard method, yet economical and technical issues prohibit its use in points of care (POC) or for repetitive tests in populations. A lot of effort has been exerted in developing, using, and validating antigen-based tests (ATs). Since individual studies focus on few methodological aspects of ATs, a comparison of different tests is needed. Herein, we perform a systematic review and meta-analysis of data from articles in PubMed, medRxiv and bioRxiv. The bivariate method for meta-analysis of diagnostic tests pooling sensitivities and specificities was used. Most of the AT types for SARS-CoV-2 were lateral flow immunoassays (LFIA), fluorescence immunoassays (FIA), and chemiluminescence enzyme immunoassays (CLEIA). We identified 235 articles containing data from 220,049 individuals. All ATs using nasopharyngeal samples show better performance than those with throat saliva (72% compared to 40%). Moreover, the rapid methods LFIA and FIA show about 10% lower sensitivity compared to the laboratory-based CLEIA method (72% compared to 82%). In addition, rapid ATs show higher sensitivity in symptomatic patients compared to asymptomatic patients, suggesting that viral load is a crucial parameter for ATs performed in POCs. Finally, all methods perform with very high specificity, reaching around 99%. LFIA tests, though with moderate sensitivity, appear as the most attractive method for use in POCs and for performing seroprevalence studies.
Collapse
Affiliation(s)
- Anastasia Tapari
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| | - Georgia G. Braliou
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| | - Maria Papaefthimiou
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| | - Helen Mavriki
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| | - Panagiota I. Kontou
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| | | | - Pantelis G. Bagos
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| |
Collapse
|
14
|
Diagnostic Performance of Antigen Rapid Diagnostic Tests, Chest Computed Tomography, and Lung Point-of-Care-Ultrasonography for SARS-CoV-2 Compared with RT-PCR Testing: A Systematic Review and Network Meta-Analysis. Diagnostics (Basel) 2022; 12:diagnostics12061302. [PMID: 35741112 PMCID: PMC9222155 DOI: 10.3390/diagnostics12061302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 05/04/2022] [Accepted: 05/20/2022] [Indexed: 12/10/2022] Open
Abstract
(1) Background: The comparative performance of various diagnostic methods for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection remains unclear. This study aimed to investigate the comparison of the 3 index test performances of rapid antigen diagnostic tests (RDTs), chest computed tomography (CT), and lung point-of-care-ultrasonography (US) with reverse transcription-polymerase chain reaction (RT-PCR), the reference standard, to provide more evidence-based data on the appropriate use of these index tests. (2) Methods: We retrieved data from electronic literature searches of PubMed, Cochrane Library, and EMBASE from 1 January 2020, to 1 April 2021. Diagnostic performance was examined using bivariate random-effects diagnostic test accuracy (DTA) and Bayesian network meta-analysis (NMA) models. (3) Results: Of the 3992 studies identified in our search, 118 including 69,445 participants met our selection criteria. Among these, 69 RDT, 38 CT, and 15 US studies in the pairwise meta-analysis were included for DTA with NMA. CT and US had high sensitivity of 0.852 (95% credible interval (CrI), 0.791–0.914) and 0.879 (95% CrI, 0.784–0.973), respectively. RDT had high specificity, 0.978 (95% CrI, 0.960–0.996). In accuracy assessment, RDT and CT had a relatively higher than US. However, there was no significant difference in accuracy between the 3 index tests. (4) Conclusions: This meta-analysis suggests that, compared with the reference standard RT-PCR, the 3 index tests (RDTs, chest CT, and lung US) had similar and complementary performances for diagnosis of SARS-CoV-2 infection. To manage and control COVID-19 effectively, future large-scale prospective studies could be used to obtain an optimal timely diagnostic process that identifies the condition of the patient accurately.
Collapse
|
15
|
Zhou K, Raoul JL, Blanc-Lapierre A, Seegers V, Boisdron-Celle M, Bourdon M, Mahammedi H, Lambert A, Moreau-Bachelard C, Campone M, Conroy T, Penault-Llorca F, Bellanger MM, Bigot F. COVID-19 Infections in Cancer Patients Were Frequently Asymptomatic: Description From a French Prospective Multicenter Cohort (PAPESCO-19). Clin Med Insights Oncol 2022; 16:11795549221090187. [PMID: 35465469 PMCID: PMC9021575 DOI: 10.1177/11795549221090187] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 03/08/2022] [Indexed: 12/15/2022] Open
Abstract
Background Cancer patients (CPs) are considered more vulnerable and as a high mortality group regarding COVID-19. In this analysis, we aimed to describe asymptomatic COVID (+) CPs and associated factors. Methods We conducted a prospective study in CPs and health care workers (HCWs) in 4 French cancer centers (PAPESCO [PAtients et PErsonnels de Santé des Centres de Lutte Contre le Cancer pendant l'épidémie de COvid-19] study). This analysis used data recorded between June 17, 2020 and November 30, 2020 in CPs (first 2 waves, no variants). At inclusion and quarterly, CPs reported the presence of predefined COVID-19 symptoms and had a blood rapid diagnostic test; a reverse transcription polymerase chain reaction (RT-PCR) was done in case of suspected infection. Results A total 878 CPs were included; COVID-19 prevalence was similar in both CPs (8%) and HCWs (9.5%); of the 70 CPs (8%) who were COVID (+), 29 (41.4%) were and remained asymptomatic; 241/808 of the COVID (-) (29.8%) were symptomatic. 18 COVID (+) were hospitalized (2% of CPs), 1 in intensive care unit (ICU) and 1 died (0.1% of CPs and 2.4% of symptomatic COVID [+] CPs). Only the inclusion center was associated with clinical presentation (in Nancy, Angers, Nantes, and Clermont-Ferrand: 65.4%, 35%, 28.6%, and 10% CPs were asymptomatic, respectively). Conclusions Seroprevalence of COVID-19 in CPs was similar to that observed in HCWs; mortality related to COVID-19 among CPs was 0.1%. More than 40% of COVID (+) CPs were asymptomatic and one third of COVID (-) CPs had symptoms. Only geographic origin was associated with the presence or absence of symptoms. Social distancing and protective measures must be applied in CPs at home and when hospitalized.
Collapse
Affiliation(s)
- Ke Zhou
- Department of Human and Social Sciences, Institut de Cancérologie de l'Ouest (ICO), Saint-Herblain, France.,Department of Social Sciences, EHESP School of Public Health, Rennes, France
| | - Jean-Luc Raoul
- Department of Medical Oncology, Institut de Cancérologie de l'Ouest, Saint-Herblain, France
| | - Audrey Blanc-Lapierre
- Department of Biostatistic, Institut de Cancérologie de l'Ouest, Saint-Herblain, France
| | - Valérie Seegers
- Department of Biostatistic, Institut de Cancérologie de l'Ouest, Saint-Herblain, France
| | | | - Marianne Bourdon
- Department of Human and Social Sciences, Institut de Cancérologie de l'Ouest (ICO), Saint-Herblain, France.,UMR, INSERM 1246 SPHERE, Nantes and Tours University, Nantes, France
| | - Hakim Mahammedi
- Department of Medical Oncology, Centre Jean Perrin, Clermont-Ferrand, France
| | - Aurélien Lambert
- Department of Medical Oncology, Institut de Cancérologie de Lorraine, Vandoeuvre-lès-Nancy, France
| | | | - Mario Campone
- Department of Medical Oncology, Institut de Cancérologie de l'Ouest, Saint-Herblain, France
| | - Thierry Conroy
- Department of Medical Oncology, Institut de Cancérologie de Lorraine, Vandoeuvre-lès-Nancy, France
| | | | - Martine M Bellanger
- Department of Human and Social Sciences, Institut de Cancérologie de l'Ouest (ICO), Saint-Herblain, France.,Department of Social Sciences, EHESP School of Public Health, Rennes, France
| | - Frédéric Bigot
- Department of Medical Oncology, Institut de Cancérologie de l'Ouest, Angers, France
| |
Collapse
|
16
|
Chen PH, Huang CC, Wu CC, Chen PH, Tripathi A, Wang YL. Saliva-based COVID-19 detection: A rapid antigen test of SARS-CoV-2 nucleocapsid protein using an electrical-double-layer gated field-effect transistor-based biosensing system. SENSORS AND ACTUATORS. B, CHEMICAL 2022; 357:131415. [PMID: 35043033 PMCID: PMC8758198 DOI: 10.1016/j.snb.2022.131415] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 01/08/2022] [Accepted: 01/10/2022] [Indexed: 05/20/2023]
Abstract
Facing the unstopped surges of COVID-19, an insufficient capacity of diagnostic testing jeopardizes the control of disease spread. Due to a centralized setting and a long turnaround, real-time reverse transcription polymerase chain reaction (real-time RT-PCR), the gold standard of viral detection, has fallen short in timely reflecting the epidemic status quo during an urgent outbreak. As such, a rapid screening tool is necessitated to help contain the spread of COVID-19 amid the countries where the vaccine implementations have not been widely deployed. In this work, we propose a saliva-based COVID-19 antigen test using the electrical double layer (EDL)-gated field-effect transistor-based biosensor (BioFET). The detection of SARS-CoV-2 nucleocapsid (N) protein is validated with limits of detection (LoDs) of 0.34 ng/mL (7.44 pM) and 0.14 ng/mL (2.96 pM) in 1× PBS and artificial saliva, respectively. The specificity is inspected with types of antigens, exhibiting low cross-reactivity among MERS-CoV, Influenza A virus, and Influenza B virus. This portable system is embedded with Bluetooth communication and user-friendly interfaces that are fully compatible with digital health, feasibly leading to an on-site turnaround, an effective management, and a proactive response taken by medical providers and frontline health workers.
Collapse
Affiliation(s)
- Pin-Hsuan Chen
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| | - Chih-Cheng Huang
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| | - Chia-Che Wu
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| | - Po-Hsuan Chen
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| | - Adarsh Tripathi
- Institute of Molecular Medicine, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| | - Yu-Lin Wang
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| |
Collapse
|
17
|
Chen PH, Huang CC, Wu CC, Chen PH, Tripathi A, Wang YL. Saliva-based COVID-19 detection: A rapid antigen test of SARS-CoV-2 nucleocapsid protein using an electrical-double-layer gated field-effect transistor-based biosensing system. SENSORS AND ACTUATORS. B, CHEMICAL 2022; 357:131415. [PMID: 35043033 DOI: 10.1016/j.snb.2022.131412] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 01/08/2022] [Accepted: 01/10/2022] [Indexed: 05/27/2023]
Abstract
Facing the unstopped surges of COVID-19, an insufficient capacity of diagnostic testing jeopardizes the control of disease spread. Due to a centralized setting and a long turnaround, real-time reverse transcription polymerase chain reaction (real-time RT-PCR), the gold standard of viral detection, has fallen short in timely reflecting the epidemic status quo during an urgent outbreak. As such, a rapid screening tool is necessitated to help contain the spread of COVID-19 amid the countries where the vaccine implementations have not been widely deployed. In this work, we propose a saliva-based COVID-19 antigen test using the electrical double layer (EDL)-gated field-effect transistor-based biosensor (BioFET). The detection of SARS-CoV-2 nucleocapsid (N) protein is validated with limits of detection (LoDs) of 0.34 ng/mL (7.44 pM) and 0.14 ng/mL (2.96 pM) in 1× PBS and artificial saliva, respectively. The specificity is inspected with types of antigens, exhibiting low cross-reactivity among MERS-CoV, Influenza A virus, and Influenza B virus. This portable system is embedded with Bluetooth communication and user-friendly interfaces that are fully compatible with digital health, feasibly leading to an on-site turnaround, an effective management, and a proactive response taken by medical providers and frontline health workers.
Collapse
Affiliation(s)
- Pin-Hsuan Chen
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| | - Chih-Cheng Huang
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| | - Chia-Che Wu
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| | - Po-Hsuan Chen
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| | - Adarsh Tripathi
- Institute of Molecular Medicine, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| | - Yu-Lin Wang
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 300044, Taiwan (R.O.C.)
| |
Collapse
|
18
|
Yin N, Debuysschere C, Daubie V, Hildebrand M, Martin C, Curac S, Ponthieux F, Payen MC, Vandenberg O, Hallin M. Evaluation and Modelling of the Performance of an Automated SARS-CoV-2 Antigen Assay According to Sample Type, Target Population and Epidemic Trends. Diagnostics (Basel) 2022; 12:diagnostics12020447. [PMID: 35204538 PMCID: PMC8871059 DOI: 10.3390/diagnostics12020447] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 02/03/2022] [Accepted: 02/07/2022] [Indexed: 12/04/2022] Open
Abstract
The Lumipulse® G SARS-CoV-2 Ag assay performance was evaluated on prospectively collected saliva and nasopharyngeal swabs (NPS) of recently ill in- and outpatients and according to the estimated viral load. Performances were calculated using RT-PCR positive NPS from patients with symptoms ≤ 7 days and RT-PCR negative NPS as gold standard. In addition, non-selected positive NPS were analyzed to assess the performances on various viral loads. This assay yielded a sensitivity of 93.1% on NPS and 71.4% on saliva for recently ill patients. For NPS with a viral load > 103 RNA copies/mL, sensitivity was 96.4%. A model established on our daily routine showed fluctuations of the performances depending on the epidemic trends but an overall good negative predictive value. Lumipulse® G SARS-CoV-2 assay yielded good performance for an automated antigen detection assay on NPS. Using it for the detection of recently ill patients or to screen high-risk patients could be an interesting alternative to the more expensive RT-PCR.
Collapse
Affiliation(s)
- Nicolas Yin
- Department of Microbiology, Laboratoire Hospitalier Universitaire de Bruxelles-Universitair Laboratorium Brussel (LHUB-ULB), Université Libre de Bruxelles (ULB), 1000 Brussels, Belgium; (C.D.); (V.D.); (F.P.); (M.H.)
- Correspondence:
| | - Cyril Debuysschere
- Department of Microbiology, Laboratoire Hospitalier Universitaire de Bruxelles-Universitair Laboratorium Brussel (LHUB-ULB), Université Libre de Bruxelles (ULB), 1000 Brussels, Belgium; (C.D.); (V.D.); (F.P.); (M.H.)
| | - Valery Daubie
- Department of Microbiology, Laboratoire Hospitalier Universitaire de Bruxelles-Universitair Laboratorium Brussel (LHUB-ULB), Université Libre de Bruxelles (ULB), 1000 Brussels, Belgium; (C.D.); (V.D.); (F.P.); (M.H.)
| | - Marc Hildebrand
- Department of Internal Medicine, Erasme University Hospital, Université Libre de Bruxelles (ULB), 1070 Brussels, Belgium;
| | - Charlotte Martin
- Department of Infectious Diseases, Saint-Pierre University Hospital, Université Libre de Bruxelles (ULB), 1000 Brussels, Belgium; (C.M.); (M.-C.P.)
| | - Sonja Curac
- Emergency Department, Erasme University Hospital, Université Libre de Bruxelles (ULB), 1070 Brussels, Belgium;
| | - Fanny Ponthieux
- Department of Microbiology, Laboratoire Hospitalier Universitaire de Bruxelles-Universitair Laboratorium Brussel (LHUB-ULB), Université Libre de Bruxelles (ULB), 1000 Brussels, Belgium; (C.D.); (V.D.); (F.P.); (M.H.)
| | - Marie-Christine Payen
- Department of Infectious Diseases, Saint-Pierre University Hospital, Université Libre de Bruxelles (ULB), 1000 Brussels, Belgium; (C.M.); (M.-C.P.)
| | - Olivier Vandenberg
- Centre for Environmental Health and Occupational Health, School of Public Health, Université Libre de Bruxelles (ULB), 1050 Brussels, Belgium;
- Clinical Research and Innovation Unit, Laboratoire Hospitalier Universitaire de Bruxelles-Universitair Laboratorium Brussel (LHUB-ULB), Université Libre de Bruxelles (ULB), 1000 Brussels, Belgium
- Division of Infection and Immunity, Faculty of Medical Sciences, University College London, London WC1E 6BT, UK
| | - Marie Hallin
- Department of Microbiology, Laboratoire Hospitalier Universitaire de Bruxelles-Universitair Laboratorium Brussel (LHUB-ULB), Université Libre de Bruxelles (ULB), 1000 Brussels, Belgium; (C.D.); (V.D.); (F.P.); (M.H.)
- Centre for Environmental Health and Occupational Health, School of Public Health, Université Libre de Bruxelles (ULB), 1050 Brussels, Belgium;
| |
Collapse
|
19
|
Fernández-Rivas G, Barallat J, Gonzalez V, Martinez S, Bordoy AE, Jimenez L, Casañ C, Blanco I. Analytical Performance of Quantitative DiaSorin Liaison SARS-COV-2 Antigen Test for the Asymptomatic Population. Front Public Health 2022; 9:788581. [PMID: 35071169 PMCID: PMC8777041 DOI: 10.3389/fpubh.2021.788581] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2021] [Accepted: 11/22/2021] [Indexed: 11/25/2022] Open
Abstract
Background: Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) antigen (Ag) tests have been widely employed to identify patients for a rapid diagnosis and pandemic control. Rapid lateral-flow techniques are currently the most used, but automated technologies have emerged as another viable alternative to molecular methods. We aimed to evaluate the analytical performance of the DiaSorin Liaison SARS-CoV-2 Ag test in asymptomatic population and close contacts, for its use as a tool in pandemic control efforts. Material and Methods: A retrospective study was conducted. A total of 861 samples were included, 291 (34%) were positive for SARS-CoV-2 with cycle threshold (Ct) <40, and 570 (66%) were negative. Results: A strong correlation was observed between reverse transcriptase-PCR (RT-PCR) Ct and Ag 50% Tissue Culture Infectious Dose per milliliter (TCID50/ml; r = 0.6486; p < 0.0001) and all RT-PCR negative samples tested negative for the 200 TCID50/ml SARS-Cov-2 Ag cutoff, i.e., a specificity of 100% was reached (95% CI: 99.4–100.0%). Samples with <25 Ct and/or >106 extrapolated copies/ml were reached a sensitivity of 100% (95% IC 97.0–100.0%). For intermediate viral loads (>105 extrapolated copies/ml or <30 Ct), the sensitivity value still exceeded 80%. As with other Ag methods, samples between 30 and 40 Ct could not be detected with a reliable sensitivity. Conclusions: The LIAISON® SARS-CoV-2 Ag assay displays an acceptable sensitivity and a very high specificity that is useful for detecting the presence of SARS-CoV-2 in nasal swabs (NPS) of asymptomatic population or to regular monitoring of risk groups in controlled settings. Additionally, the flexibility in processing different samples and in the sampling preparation process makes this test an option for its use in high throughput laboratories. Automated tests may facilitate result reporting and yield consistent data, while avoiding some of the pitfalls of rapid lateral-flow techniques, such as observer variability.
Collapse
Affiliation(s)
- Gema Fernández-Rivas
- Microbiology Department, Clinical Laboratory North Metropolitan Area, Germans Trias i Pujol University Hospital, Badalona, Spain.,Department of Genetics and Microbiology, Autonomous University of Barcelona, Badalona, Spain
| | - Jaume Barallat
- Biochemistry Department, Germans Trias i Pujol University Hospital, Badalona, Spain
| | - Victoria Gonzalez
- Microbiology Department, Clinical Laboratory North Metropolitan Area, Germans Trias i Pujol University Hospital, Badalona, Spain.,Center for Epidemiological Studies on Human Immunodeficiency Virus Infection and Acquired Immunodeficiency Syndrome (HIV/AIDS) and Sexually Transmitted Infections (STI) of Catalonia (CEEISCAT), Generalitat de Catalunya, Badalona, Spain.,Centro de Investigación Biomédica en Red (CIBER) in Epidemiology and Public Health (CIBERESP), Madrid, Spain
| | - Silvia Martinez
- Biochemistry Department, Germans Trias i Pujol University Hospital, Badalona, Spain
| | - Antoni E Bordoy
- Metropolitana Nord Laboratory, Germans Trias i Pujol University Hospital, Badalona, Spain
| | - Laura Jimenez
- Biochemistry Department, Germans Trias i Pujol University Hospital, Badalona, Spain
| | - Cristina Casañ
- Microbiology Department, Clinical Laboratory North Metropolitan Area, Germans Trias i Pujol University Hospital, Badalona, Spain
| | - Ignacio Blanco
- Metropolitana Nord Laboratory, Germans Trias i Pujol University Hospital, Badalona, Spain
| |
Collapse
|
20
|
Khalid MF, Selvam K, Jeffry AJN, Salmi MF, Najib MA, Norhayati MN, Aziah I. Performance of Rapid Antigen Tests for COVID-19 Diagnosis: A Systematic Review and Meta-Analysis. Diagnostics (Basel) 2022; 12:diagnostics12010110. [PMID: 35054277 PMCID: PMC8774565 DOI: 10.3390/diagnostics12010110] [Citation(s) in RCA: 53] [Impact Index Per Article: 26.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 12/30/2021] [Accepted: 12/30/2021] [Indexed: 02/04/2023] Open
Abstract
The identification of viral RNA using reverse transcription quantitative polymerase chain reaction (RT-qPCR) is the gold standard for identifying an infection caused by SARS-CoV-2. The limitations of RT-qPCR such as requirement of expensive instruments, trained staff and laboratory facilities led to development of rapid antigen tests (RATs). The performance of RATs has been widely evaluated and found to be varied in different settings. The present systematic review aims to evaluate the pooled sensitivity and specificity of the commercially available RATs. This review was registered on PROSPERO (registration number: CRD42021278105). Literature search was performed through PubMed, Embase and Cochrane COVID-19 Study Register to search studies published up to 26 August 2021. The overall pooled sensitivity and specificity of RATs and subgroup analyses were calculated. Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to assess the risk of bias in each study. The overall pooled sensitivity and specificity of RATs were 70% (95% CI: 69–71) and 98% (95% CI: 98–98), respectively. In subgroup analyses, nasal swabs showed the highest sensitivity of 83% (95% CI: 80–86) followed by nasopharyngeal swabs 71% (95% CI: 70–72), throat swabs 69% (95% CI: 63–75) and saliva 68% (95% CI: 59–77). Samples from symptomatic patients showed a higher sensitivity of 82% (95% CI: 82–82) as compared to asymptomatic patients at 68% (95% CI: 65–71), while a cycle threshold (Ct) value ≤25 showed a higher sensitivity of 96% (95% CI: 95–97) as compared to higher Ct value. Although the sensitivity of RATs needs to be enhanced, it may still be a viable option in places where laboratory facilities are lacking for diagnostic purposes in the early phase of disease.
Collapse
Affiliation(s)
- Muhammad Fazli Khalid
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (M.F.K.); (K.S.); (M.A.N.)
| | - Kasturi Selvam
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (M.F.K.); (K.S.); (M.A.N.)
| | - Alfeq Jazree Nashru Jeffry
- Faculty of Resource Science and Technology (FRST), Universiti Malaysia Sarawak, Kota Samarahan 94300, Sarawak, Malaysia; (A.J.N.J.); (M.F.S.)
| | - Mohamad Fazrul Salmi
- Faculty of Resource Science and Technology (FRST), Universiti Malaysia Sarawak, Kota Samarahan 94300, Sarawak, Malaysia; (A.J.N.J.); (M.F.S.)
| | - Mohamad Ahmad Najib
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (M.F.K.); (K.S.); (M.A.N.)
| | - Mohd Noor Norhayati
- Department of Family Medicine, School of Medical Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia;
| | - Ismail Aziah
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (M.F.K.); (K.S.); (M.A.N.)
- Correspondence:
| |
Collapse
|
21
|
Comparison of Rapid and Automated Antigen Detection Tests for the Diagnosis of SARS-CoV-2 Infection. Diagnostics (Basel) 2022; 12:diagnostics12010104. [PMID: 35054271 PMCID: PMC8775255 DOI: 10.3390/diagnostics12010104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 12/23/2021] [Accepted: 12/27/2021] [Indexed: 11/17/2022] Open
Abstract
SARS-CoV-2 viral antigen detection may be an interesting alternative to RT-PCR for the diagnosis of SARS-CoV-2 infection as a less laborious or expensive method but requires validation. This study aimed to compare the performance of the DiaSorin™ LiaisonXL automated quantitative antigen test (QAT) and the AAZ™ rapid antigen test (RAT) to the DiaSorin™ MDX RT-PCR assay. A total of 242 nasopharyngeal samples were tested at La Pitié-Salpêtrière University Hospital (Paris, France). Performances for the detection of variants of SARS-CoV-2 were further investigated. RATs were visually read for qualitative results and band intensity was determined. Overall sensitivity was 63.2% for QAT and 58.6% for RAT. For RT-PCR Ct value 25, sensitivity was 89.8% for both tests. Both tests showed comparable sensitivity for detection of variants. There was a strong relationship between antigen concentration and band positivity. On the same set of samples these tests share similar performances.
Collapse
|
22
|
Tran NK, May L. Evolution of COVID-19 Testing and the Role of Rapid Antigen Testing in Molecular-Focused World. Arch Pathol Lab Med 2021; 146:404-406. [DOI: 10.5858/arpa.2021-0610-ed] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/27/2021] [Indexed: 11/06/2022]
Affiliation(s)
- Nam K. Tran
- From the Department of Pathology and Laboratory Medicine (Tran), University of California, Davis
| | - Larissa May
- Department of Emergency Medicine (May), University of California, Davis
| |
Collapse
|
23
|
Altawalah H, Alfouzan W, Al-Fadalah T, Ezzikouri S. Diagnostic Performance of Automated SARS-CoV-2 Antigen Assay in Nasal Swab during COVID-19 Vaccination Campaign. Diagnostics (Basel) 2021; 11:2110. [PMID: 34829457 PMCID: PMC8621910 DOI: 10.3390/diagnostics11112110] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 11/05/2021] [Accepted: 11/11/2021] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND To control the spread of the pandemic brought about by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, it is necessary to have an automated reliable diagnostic assay. To date, the RT-PCR (RT-qPCR) has been the recommended laboratory method to diagnose SARS-CoV-2 infection, but there is a need for more automated and reliable tests. The aim of this real-life study was to assess the diagnostic performance of DiaSorin's LIAISON SARS-CoV-2 antigen (Ag) chemiluminescence immunoassay in detecting SARS-CoV-2 in vaccinated and unvaccinated individuals. METHODS A prospective study was performed on 300 nasopharyngeal swabs randomly collected from 31 May to 6 July 2021. Nasopharyngeal samples were assayed with DiaSorin's LIAISON SARS-CoV-2 Ag and TaqPath™ COVID-19 multiplex RT-qPCR. RESULTS Of 300 participants, 150 had a RT-qPCR confirmed SARS-CoV-2 infection of whom 113 (75.33%) were also detected by the DiaSorin LIAISON SARS-CoV-2 Ag. Taking RT-qPCR as a reference, the sensitivity and specificity of the DiaSorin LIAISON SARS-CoV-2 Ag assay were evaluated as 75.33% (95% CI = 67.64-82) and 100% (95% CI = 97.57-100), respectively. When a viral load cut-off was applied for high viral load (median cycle threshold (Ct) < 18.57), the overall sensitivity was increased to 96.55% (95% CI = 88.09-99.58). Interestingly, median RT-qPCR Ct and SARS-CoV-2 Ag values were similar between fully vaccinated and unvaccinated subjects. CONCLUSIONS Automated, quantitative LIAISON SARS-CoV-2 Ag assay shows good performance to identify SARS-CoV-2-infected individuals with moderate to high viral loads. LIAISON SARS-CoV-2 Ag testing could be used as frontline testing for COVID-19 diagnosis and be more suitable for large utilization.
Collapse
Affiliation(s)
- Haya Altawalah
- Department of Microbiology, Faculty of Medicine, Kuwait University, Safat 24923, Kuwait;
- Virology Unit, Yacoub Behbehani Center, Sabah Hospital, Ministry of Health, Safat 24923, Kuwait
| | - Wadha Alfouzan
- Department of Microbiology, Faculty of Medicine, Kuwait University, Safat 24923, Kuwait;
- Laboratory Medicine, Farwania Hospital, Ministry of Health, Farwania 85000, Kuwait
| | - Talal Al-Fadalah
- Qualities and Accreditation Directorate, Ministry of Health, Safat 13001, Kuwait;
| | - Sayeh Ezzikouri
- Virology Unit, Viral Hepatitis Laboratory, Institut Pasteur du Maroc, Casablanca 20250, Morocco
| |
Collapse
|
24
|
Evaluation of the Elecsys SARS-CoV-2 antigen assay for the detection of SARS-CoV-2 in nasopharyngeal swabs. J Clin Virol 2021; 144:104991. [PMID: 34626880 PMCID: PMC8485719 DOI: 10.1016/j.jcv.2021.104991] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 09/09/2021] [Accepted: 09/23/2021] [Indexed: 11/17/2022]
Abstract
Aims The aim of this study was to evaluate the performance of the automated Elecsys® SARS-CoV-2 antigen assay compared to RT-PCR taken as the gold standard for SARS-CoV-2 detection. Methods 225 nasopharyngeal swabs were randomly collected among which 123 were tested positive and 102 negatives for SARS-CoV-2 based on RT-PCR. Antigen dosing were performed on a Cobas 8000 e801 analyzer. Results The antigen test diagnosed SARS-CoV-2 infection status with an overall sensitivity of 65,85% (95% CI 56,76–74,16%), a specificity of 100% (95% CI 96,49–100%) with a Cut-off value ≥ 1. When the cut-off value for the antigen assay was set to > 0,673 COI, the accuracy reached its highest level with a sensitivity of 74,8% (95% CI 66,2 – 82,2%) and a specificity of 97,1% (95% CI 91,6 – 99,4%). Imprecision was estimated in accordance with manufacturer's claims. Conclusions We obtained an overall sensitivity of 65,85% (95% CI 56,76–74,16%) and a specificity of 100% (95% CI 96,49–100%), slightly higher than the results reported by the manufacturer. Yet, it remains relatively low comparatively to what is generally acceptable for these antigenic assays (a relative sensitivity of 80%). We also noticed that the accuracy could reach its highest level if the cut-off is set above 0,673 which is lower than established by the manufacturer. Thus, our results suggest that the Elecsys® SARS-CoV-2 Antigen assays, should be improved prior to be used in a SARS-Cov-2 screening strategy. However, if one antigenic assay could demonstrate acceptable performance, it might be centralized in clinical laboratories, keeping the RT-PCR in a second phase for confirmation.
Collapse
|
25
|
A SARS-CoV-2 nucleocapsid ELISA represents a low-cost alternative to lateral flow testing for community screening in LMI countries. J Infect 2021; 84:48-55. [PMID: 34606784 PMCID: PMC8485707 DOI: 10.1016/j.jinf.2021.08.049] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 08/27/2021] [Accepted: 08/28/2021] [Indexed: 11/25/2022]
Abstract
Background Controlling the spread of SARS-CoV-2 is problematic because of transmission driven by asymptomatic and pre-symptomatic individuals. Community screening can help identify these individuals but is often too expensive for countries with limited health care resources. Low-cost ELISA assays may address this problem, but their use has not yet been widely reported. Methods We developed a SARS-CoV-2 nucleocapsid ELISA and assessed its diagnostic performance on nose and throat swab samples from UK hospitalised patients and sputum samples from patients in Ghana. Results The ELISA had a limit of detection of 8.4 pg/ml antigen and 16 pfu/ml virus. When tested on UK samples (128 positive and 10 negative patients), sensitivity was 58.6% (49.6–67.2) rising to 78.3% (66.7–87.3) if real-time PCR Ct values > 30 were excluded, while specificity was 100% (69.2–100). In a second trial using the Ghanaian samples (121 positive, 96 negative), sensitivity was 52% (42.8–61.2) rising to 72.6% (61.8–81.2) when a > 30 Ct cut-off was applied, while specificity was 100% (96.2–100). Conclusions: Our data show that nucleocapsid ELISAs can test a variety of patient sample types while achieving levels of sensitivity and specificity required for effective community screening. Further investigations into the opportunities that this provides are warranted.
Collapse
|
26
|
Osterman A, Iglhaut M, Lehner A, Späth P, Stern M, Autenrieth H, Muenchhoff M, Graf A, Krebs S, Blum H, Baiker A, Grzimek-Koschewa N, Protzer U, Kaderali L, Baldauf HM, Keppler OT. Comparison of four commercial, automated antigen tests to detect SARS-CoV-2 variants of concern. Med Microbiol Immunol 2021; 210:263-275. [PMID: 34415422 PMCID: PMC8377707 DOI: 10.1007/s00430-021-00719-0] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Accepted: 08/13/2021] [Indexed: 12/23/2022]
Abstract
A versatile portfolio of diagnostic tests is essential for the containment of the severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) pandemic. Besides nucleic acid-based test systems and point-of-care (POCT) antigen (Ag) tests, quantitative, laboratory-based nucleocapsid Ag tests for SARS-CoV-2 have recently been launched. Here, we evaluated four commercial Ag tests on automated platforms and one POCT to detect SARS-CoV-2. We evaluated PCR-positive (n = 107) and PCR-negative (n = 303) respiratory swabs from asymptomatic and symptomatic patients at the end of the second pandemic wave in Germany (February–March 2021) as well as clinical isolates EU1 (B.1.117), variant of concern (VOC) Alpha (B.1.1.7) or Beta (B.1.351), which had been expanded in a biosafety level 3 laboratory. The specificities of automated SARS-CoV-2 Ag tests ranged between 97.0 and 99.7% (Lumipulse G SARS-CoV-2 Ag (Fujirebio): 97.03%, Elecsys SARS-CoV-2 Ag (Roche Diagnostics): 97.69%; LIAISON® SARS-CoV-2 Ag (Diasorin) and SARS-CoV-2 Ag ELISA (Euroimmun): 99.67%). In this study cohort of hospitalized patients, the clinical sensitivities of tests were low, ranging from 17.76 to 52.34%, and analytical sensitivities ranged from 420,000 to 25,000,000 Geq/ml. In comparison, the detection limit of the Roche Rapid Ag Test (RAT) was 9,300,000 Geq/ml, detecting 23.58% of respiratory samples. Receiver-operating-characteristics (ROCs) and Youden’s index analyses were performed to further characterize the assays’ overall performance and determine optimal assay cutoffs for sensitivity and specificity. VOCs carrying up to four amino acid mutations in nucleocapsid were detected by all five assays with characteristics comparable to non-VOCs. In summary, automated, quantitative SARS-CoV-2 Ag tests show variable performance and are not necessarily superior to a standard POCT. The efficacy of any alternative testing strategies to complement nucleic acid-based assays must be carefully evaluated by independent laboratories prior to widespread implementation.
Collapse
Affiliation(s)
- Andreas Osterman
- Max Von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Maximilian Iglhaut
- Max Von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Andreas Lehner
- Max Von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Patricia Späth
- Max Von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Marcel Stern
- Max Von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Hanna Autenrieth
- Max Von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
| | - Maximilian Muenchhoff
- Max Von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
- German Center for Infection Research (DZIF), Partner Site, Munich, Germany
- COVID-19 Registry of the LMU Munich (CORKUM), University Hospital, LMU Munich, Munich, Germany
| | - Alexander Graf
- Laboratory for Functional Genome Analysis, Gene Center, LMU München, Munich, Germany
| | - Stefan Krebs
- Laboratory for Functional Genome Analysis, Gene Center, LMU München, Munich, Germany
| | - Helmut Blum
- Laboratory for Functional Genome Analysis, Gene Center, LMU München, Munich, Germany
| | - Armin Baiker
- Public Health Microbiology Unit, Bavarian Health and Food Safety Authority, Oberschleißheim, Germany
| | - Natascha Grzimek-Koschewa
- Max Von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany
- German Center for Infection Research (DZIF), Partner Site, Munich, Germany
| | - Ulrike Protzer
- German Center for Infection Research (DZIF), Partner Site, Munich, Germany
- Institute of Virology, Technical University of Munich/Helmholtz Zentrum München, Munich, Germany
| | - Lars Kaderali
- Institute of Bioinformatics, University Medicine Greifswald, Greifswald, Germany
| | - Hanna-Mari Baldauf
- Max Von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany.
- Max Von Pettenkofer Institute, Virology, National Reference Center for Retroviruses, LMU München, Feodor-Lynen-Str. 23, 81377, Munich, Germany.
| | - Oliver T Keppler
- Max Von Pettenkofer Institute and Gene Center, Virology, National Reference Center for Retroviruses, LMU München, Munich, Germany.
- German Center for Infection Research (DZIF), Partner Site, Munich, Germany.
- COVID-19 Registry of the LMU Munich (CORKUM), University Hospital, LMU Munich, Munich, Germany.
- Max Von Pettenkofer Institute, Virology, National Reference Center for Retroviruses, LMU München, Pettenkoferstr. 9a, 80336, Munich, Germany.
| |
Collapse
|
27
|
Brümmer LE, Katzenschlager S, Gaeddert M, Erdmann C, Schmitz S, Bota M, Grilli M, Larmann J, Weigand MA, Pollock NR, Macé A, Carmona S, Ongarello S, Sacks JA, Denkinger CM. Accuracy of novel antigen rapid diagnostics for SARS-CoV-2: A living systematic review and meta-analysis. PLoS Med 2021; 18:e1003735. [PMID: 34383750 PMCID: PMC8389849 DOI: 10.1371/journal.pmed.1003735] [Citation(s) in RCA: 159] [Impact Index Per Article: 53.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 08/26/2021] [Accepted: 07/14/2021] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND SARS-CoV-2 antigen rapid diagnostic tests (Ag-RDTs) are increasingly being integrated in testing strategies around the world. Studies of the Ag-RDTs have shown variable performance. In this systematic review and meta-analysis, we assessed the clinical accuracy (sensitivity and specificity) of commercially available Ag-RDTs. METHODS AND FINDINGS We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched multiple databases (PubMed, Web of Science Core Collection, medRvix, bioRvix, and FIND) for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 up until 30 April 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity in comparison to reverse transcription polymerase chain reaction (RT-PCR) testing. We assessed heterogeneity by subgroup analyses, and rated study quality and risk of bias using the QUADAS-2 assessment tool. From a total of 14,254 articles, we included 133 analytical and clinical studies resulting in 214 clinical accuracy datasets with 112,323 samples. Across all meta-analyzed samples, the pooled Ag-RDT sensitivity and specificity were 71.2% (95% CI 68.2% to 74.0%) and 98.9% (95% CI 98.6% to 99.1%), respectively. Sensitivity increased to 76.3% (95% CI 73.1% to 79.2%) if analysis was restricted to studies that followed the Ag-RDT manufacturers' instructions. LumiraDx showed the highest sensitivity, with 88.2% (95% CI 59.0% to 97.5%). Of instrument-free Ag-RDTs, Standard Q nasal performed best, with 80.2% sensitivity (95% CI 70.3% to 87.4%). Across all Ag-RDTs, sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values, i.e., <20 (96.5%, 95% CI 92.6% to 98.4%) and <25 (95.8%, 95% CI 92.3% to 97.8%), in comparison to those with Ct ≥ 25 (50.7%, 95% CI 35.6% to 65.8%) and ≥30 (20.9%, 95% CI 12.5% to 32.8%). Testing in the first week from symptom onset resulted in substantially higher sensitivity (83.8%, 95% CI 76.3% to 89.2%) compared to testing after 1 week (61.5%, 95% CI 52.2% to 70.0%). The best Ag-RDT sensitivity was found with anterior nasal sampling (75.5%, 95% CI 70.4% to 79.9%), in comparison to other sample types (e.g., nasopharyngeal, 71.6%, 95% CI 68.1% to 74.9%), although CIs were overlapping. Concerns of bias were raised across all datasets, and financial support from the manufacturer was reported in 24.1% of datasets. Our analysis was limited by the included studies' heterogeneity in design and reporting. CONCLUSIONS In this study we found that Ag-RDTs detect the vast majority of SARS-CoV-2-infected persons within the first week of symptom onset and those with high viral load. Thus, they can have high utility for diagnostic purposes in the early phase of disease, making them a valuable tool to fight the spread of SARS-CoV-2. Standardization in conduct and reporting of clinical accuracy studies would improve comparability and use of data.
Collapse
Affiliation(s)
- Lukas E. Brümmer
- Division of Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Mary Gaeddert
- Division of Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Stephani Schmitz
- Division of Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
| | - Marc Bota
- Agaplesion Bethesda Hospital, Hamburg, Germany
| | - Maurizio Grilli
- Library, University Medical Center Mannheim, Mannheim, Germany
| | - Jan Larmann
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Markus A. Weigand
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Nira R. Pollock
- Department of Laboratory Medicine, Boston Children’s Hospital, Boston, Massachusetts, United States of America
| | | | | | | | | | - Claudia M. Denkinger
- Division of Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
- Partner Site Heidelberg University Hospital, German Center for Infection Research (DZIF), Heidelberg, Germany
| |
Collapse
|
28
|
Fernandez-Montero A, Argemi J, Rodríguez JA, Ariño AH, Moreno-Galarraga L. Validation of a rapid antigen test as a screening tool for SARS-CoV-2 infection in asymptomatic populations. Sensitivity, specificity and predictive values. EClinicalMedicine 2021; 37:100954. [PMID: 34127960 PMCID: PMC8189541 DOI: 10.1016/j.eclinm.2021.100954] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 05/14/2021] [Accepted: 05/20/2021] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND Early diagnosis of SARS-CoV-2 infection is essential to reduce disease spread. Rapid antigen tests have not been sufficiently evaluated in asymptomatic patients to be used as massive population screening tools. METHODS Head-to-head evaluation of Roche SARS-CoV-2 Rapid Antigen Test and real-time reverse transcription polymerase chain reaction (RT-PCR) as SARS-CoV-2 screening tools performed in asymptomatic adults from a semi-closed community in University of Navarra (Spain) from November 2020 to January 2021. Sensitivity, specificity and predictive values were calculated using RT-PCR as reference method. FINDINGS Roche SARS-CoV-2 Rapid Antigen Test was performed on 2542 asymptomatic adults in a community with a SARS-CoV-2 incidence of 1·93%. It showed a sensitivity of 71·43% (CI 95%: 56·74 - 83·42) and a specificity of 99·68% (CI 95%: 99·37 - 99·86). Positive Predictive Value was 81·4 (CI 95% 66·6 - 91·61) and Negative Predictive Value was 99·44 (CI 95% 99·06 - 99·69). Test sensitivity was related to viral load, with higher sensitivity in RT-PCR cycle threshold (Ct) values under 25 (93·75%, CI 95%: 71·96 - 98·93), that dropped to 29·41% (CI 95%: 10·31- 55·96) in RT-PCR Ct values above 25. INTERPRETATION This study suggests that rapid antigen tests are less effective in asymptomatic population, when compared with RT-PCR. Further studies are needed to evaluate different options to improve screenings based on rapid antigen test, such as the use of clinical questionnaires to select higher risk-participants, the confirmation of negative results with RT-PCR or the use of repetitive sequential testing. FUNDING This research received no external funding.
Collapse
Affiliation(s)
- Alejandro Fernandez-Montero
- Department of Occupational Medicine, University of Navarra, Av. Pío XII, 36, Pamplona, Spain
- IdiSNA (Instituto de Investigación Sanitaria de Navarra), Pamplona, Spain
- Corresponding author at: Department of Occupational Medicine, University of Navarra, Av. Pío XII, 36, Pamplona, Spain.
| | - Josepmaria Argemi
- IdiSNA (Instituto de Investigación Sanitaria de Navarra), Pamplona, Spain
- Liver Unit, Clinica Universidad de Navarra, Hepatology Program, CIMA-Universidad de Navarra, Pamplona, Spain
| | - José Antonio Rodríguez
- IdiSNA (Instituto de Investigación Sanitaria de Navarra), Pamplona, Spain
- Atherothrombosis Laboratory, Program of Cardiovascular Diseases, CIMA-Universidad de Navarra, Pamplona, Spain
- CIBERCV, ISCIII, Madrid, Spain
| | - Arturo H. Ariño
- Department of Environmental Biology, University of Navarra, Pamplona, Spain
| | - Laura Moreno-Galarraga
- IdiSNA (Instituto de Investigación Sanitaria de Navarra), Pamplona, Spain
- Department of Pediatrics, Complejo Hospitalario de Navarra, Servicio Navarro de Salud, Pamplona, Spain
- Department of Preventive Medecine and Public Health, Universidad Publica de Navarra, Pamplona, Spain
| |
Collapse
|
29
|
Salvagno GL, Gianfilippi G, Fiorio G, Pighi L, De Nitto S, Henry BM, Lippi G. Clinical Assessment of the DiaSorin LIAISON SARS-CoV-2 Ag Chemiluminescence Immunoassay. EJIFCC 2021; 32:216-223. [PMID: 34421491 PMCID: PMC8343054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 10/29/2022]
Abstract
BACKGROUND Due to the large volume of tests needed in a relatively short time for screening and diagnosing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, antigen immunoassays may provide a potential supplement to molecular testing. This study was aimed to assess the clinical preference of DiaSorin LIAISON SARS-CoV-2 Ag chemiluminescence immunoassay. METHODS An upper respiratory specimen was collected in a series of patients referred to the Laboratory Medicine service of Pederzoli Hospital (Peschiera del Garda, Verona, Italy) for screening or diagnosis of SARS-CoV-2 infection. Nasopharyngeal samples were assayed with DiaSorin LIAISON SARS-CoV-2 Ag test and Altona Diagnostics RealStar® SARS-CoV-2 RT-PCR Kit. RESULTS The final study population consisted of 421 patients (median age, 48 years; 227 women), 301 (71.5%) with positive result of molecular testing, and 126 (29.9%) with cycle threshold (Ct) values of both E and S genes <29.5, thus reflecting higher infectivity. The area under the curve of DiaSorin LIAISON SARS-CoV-2 Ag test 0.82 (95% CI, 0.79-0.86) for sample positivity and 0.98 for higher sample infectivity (95% CI, 0.97 to 0.99). The optimal cut-off for sample positivity was 82 TCID50/mL (0.78 sensitivity, 0.73 specificity and 77% diagnostic accuracy), whilst that for identifying samples associated with a high infective risk was 106 TCID50/mL (0.94 sensitivity, 0.96 specificity and 95% diagnostic accuracy). CONCLUSION The performance of this chemiluminescence immunoassay would not permit it to replace molecular testing for diagnosing SARS-CoV-2, but may enable rapid and efficient detection of subjects with high SARS-CoV-2 viral load, who are responsible for the largest proportion of infectious clusters.
Collapse
Affiliation(s)
- Gian Luca Salvagno
- Section of Clinical Biochemistry, University of Verona, Verona, Italy, Service of Laboratory Medicine, Pederzoli Hospital, Peschiera del Garda, Italy
| | | | - Giacomo Fiorio
- Medical Direction, Pederzoli Hospital, Peschiera del Garda, Italy
| | - Laura Pighi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Simone De Nitto
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Brandon M. Henry
- The Heart Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, Ohio, USA
| | - Giuseppe Lippi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy,Corresponding author: Prof. Giuseppe Lippi Section of Clinical Biochemistry University Hospital of Verona Piazzale L.A. Scuro, 10 37134 Verona Italy Phone: 0039-045-8122970 Fax: 0039-045-8124308 E-mail:
| |
Collapse
|