1
|
Aramberri J, Lauzirika G, Illarramendi I, Mendicute J. Comparison between a new transepithelial PRK vs. conventional alcohol-assisted PRK: Corneal densitometry and aberrometry study. Eur J Ophthalmol 2024:11206721241267360. [PMID: 39147728 DOI: 10.1177/11206721241267360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/17/2024]
Abstract
PURPOSE To describe and compare corneal densitometry, subjective refraction, visual acuity, and corneal higher order aberrations (HOA) after corneal refractive surgery using either alcohol-assisted photorefractive keratectomy (aaPRK) or single-step transepithelial PRK (tPRK). METHODS We conducted a retrospective and observational study. We analyzed 120 right eyes from 120 healthy consecutive myopic patients who underwent aaPRK or tPRK to correct myopia of up to 6 diopters and astigmatism of up to 2 diopters. The WaveLight EX500 excimer laser (Alcon Laboratories, Inc.) was used in all cases. Visual acuity, subjective refraction, and Pentacam AXL® measurements were performed at the preoperative visit and at 6-months follow-up visit. Pentacam AXL® software was used to assess corneal optical density in various annuli for different corneal depths and anterior corneal HOA (6 mm area of analysis). RESULTS Preoperative spherical equivalent values were similar between groups preoperatively (-3.07 ± 1.52 and -3.38 ± 1.46 in the aaPRK and tPRK groups, respectively). There were no statistically significant differences in visual acuity and postoperative refraction between groups. Postoperative corneal densitometry did not show statistically significant differences in any of the areas studied and both surgical procedures obtained similar results. However, analysis of HOA showed statistically significant differences between the techniques (1.42 ± 0.39 and 1.80 ± 0.62 for the aaPRK and tPRK groups, respectively; p = 0.000). CONCLUSIONS Both aaPRK and single-step tPRK gave comparable visual, refractive, and corneal density outcomes. Some differences were observed in HOA but were not clinically relevant.
Collapse
Affiliation(s)
- Jaime Aramberri
- Miranza Begitek, Donostia-San Sebastián, Spain
- Miranza Ókular, Vitoria-Gasteiz, Spain
| | - Gorka Lauzirika
- Miranza Begitek, Donostia-San Sebastián, Spain
- Miranza Group R&D Department, Spain
| | | | - Javier Mendicute
- Miranza Begitek, Donostia-San Sebastián, Spain
- Hospital Universitario Donostia, Donostia-San Sebastián, Spain
| |
Collapse
|
2
|
Lee CY, Jeng YT, Yang SF, Huang CT, Chao CC, Lian IB, Huang JY, Chang CK. Topographic and Surgical Risk Factors for Early Myopic Regression between Small Incision Lenticule Extraction and Laser In Situ Keratomileusis. Diagnostics (Basel) 2024; 14:1275. [PMID: 38928690 PMCID: PMC11202549 DOI: 10.3390/diagnostics14121275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 06/06/2024] [Accepted: 06/14/2024] [Indexed: 06/28/2024] Open
Abstract
Our objective was to evaluate the topographic and surgical factors of early myopic regression between laser in situ keratomileusis (LASIK) and small-incision lenticule extraction (SMILE). A retrospective case-control study was conducted, and 368 and 92 eyes were enrolled in the LASIK and SMILE groups via propensity score matching (PSM). Visual acuity, refractive status, axial length, and topographic/surgical parameters were collected. Multiple linear regression was applied to the yield coefficient and the 95% confidence interval (CI) of the parameters. The cumulative incidence of early myopic regression was higher in the LASIK group (p < 0.001). In the SMILE group, a lower central corneal thickness (CCT) thinnest value and a higher corneal cylinder associated with early myopic regression were observed; meanwhile, in the LASIK group, a lower CCT thinnest value, a higher steep corneal curvature, a larger optic zone, and a lower flap thickness related to early myopic regression were observed (all p < 0.05). In the SMILE group, a higher CCT difference correlated with early myopic regression was observed compared to the LASIK group (p = 0.030), and higher steep corneal curvature and lower cap/flap thickness (both p < 0.05) correlated with early myopic regression were observed in the LASIK group compared to the SMILE group. In conclusion, CCT differences significantly influence early myopic regression in the SMILE group; meanwhile, corneal curvature and flap thickness affect early myopic regression principally in the LASIK group.
Collapse
Affiliation(s)
- Chia-Yi Lee
- Institute of Medicine, Chung Shan Medical University, Taichung 402, Taiwan
- Nobel Eye Institute, Taipei 115, Taiwan
- Department of Ophthalmology, Jen-Ai Hospital Dali Branch, Taichung 412, Taiwan
| | - Yu-Ting Jeng
- Institute of Medicine, Chung Shan Medical University, Taichung 402, Taiwan
| | - Shun-Fa Yang
- Institute of Medicine, Chung Shan Medical University, Taichung 402, Taiwan
- Department of Medical Research, Chung Shan Medical University Hospital, Taichung 402, Taiwan
| | - Chin-Te Huang
- Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung 402, Taiwan
- Department of Ophthalmology, School of Medicine, Chung Shan Medical University, Taichung 402, Taiwan
| | - Chen-Cheng Chao
- Nobel Eye Institute, Taipei 115, Taiwan
- Department of Optometry, MacKay Junior College of Medicine, Nursing, and Management, Taipei 112, Taiwan
| | - Ie-Bin Lian
- Institute of Statistical and Information Science, National Changhua University of Education, Changhua 500, Taiwan
| | - Jing-Yang Huang
- Department of Medical Research, Chung Shan Medical University Hospital, Taichung 402, Taiwan
| | - Chao-Kai Chang
- Nobel Eye Institute, Taipei 115, Taiwan
- Department of Optometry, Da-Yeh University, Chunghua 515, Taiwan
| |
Collapse
|
3
|
Lee CY, Jeng YT, Chao CC, Lian IB, Huang JY, Yang SF, Chang CK. Refraction and topographic risk factors for early myopic regression after small-incision lenticule extraction surgery. Sci Rep 2024; 14:8732. [PMID: 38627567 PMCID: PMC11021515 DOI: 10.1038/s41598-024-59327-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 04/09/2024] [Indexed: 04/19/2024] Open
Abstract
We sought to evaluate the topographic risk factors for early myopic regression after small-incision lenticule extraction (SMILE). A retrospective case‒control study was conducted, and individuals who underwent SMILE surgery were enrolled. Among them, 406 and 14 eyes were categorized into the nonregression and regression groups, respectively. The preoperative and postoperative parameters in the two groups were collected, including spherical refraction (SE), axial length (AXL) and topographic data. A generalized linear model was adopted to analyze the difference in each parameter between the two groups. After 6 months, UCVA decreased in the regression group, and SE increased in the regression group (both P < 0.05). The increase in the CCT at the thinnest point (P = 0.044), flat corneal curvature (P = 0.012) and TCRP (P = 0.001) were significantly greater in the regression group. Regarding the risk factors for myopic regression, preoperative SE, preoperative sphere power, preoperative AXL, preoperative flat corneal curvature, preoperative SA, early postoperative SE, early postoperative sphere power, early postoperative AXL and early postoperative CCT difference were significantly greater in the regression group (all P < 0.05). The SE, sphere power, AXL, preoperative flat corneal curvature, preoperative SA, and postoperative CCT difference correlate with early myopic regression after SMILE.
Collapse
Affiliation(s)
- Chia-Yi Lee
- Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan
- Nobel Eye Institute, No. 13-5, Gongyuan Rd., Zhongzheng Dist., Taipei, 100008, Taiwan
- Department of Ophthalmology, Jen-Ai Hospital Dali Branch, Taichung, Taiwan
| | - Yu-Ting Jeng
- Nobel Eye Institute, No. 13-5, Gongyuan Rd., Zhongzheng Dist., Taipei, 100008, Taiwan
| | - Chen-Cheng Chao
- Nobel Eye Institute, No. 13-5, Gongyuan Rd., Zhongzheng Dist., Taipei, 100008, Taiwan
- Department of Optometry, MacKay Junior College of Medicine, Nursing, and Management, Taipei, Taiwan
| | - Ie-Bin Lian
- Institute of Statistical and Information Science, National Changhua University of Education, Changhua, Taiwan
| | - Jing-Yang Huang
- Department of Medical Research, Chung Shan Medical University Hospital, Taichung, Taiwan
| | - Shun-Fa Yang
- Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan.
- Department of Medical Research, Chung Shan Medical University Hospital, Taichung, Taiwan.
| | - Chao-Kai Chang
- Nobel Eye Institute, No. 13-5, Gongyuan Rd., Zhongzheng Dist., Taipei, 100008, Taiwan.
- Department of Optometry, Da-Yeh University, Chunghua, Taiwan.
| |
Collapse
|
4
|
Chen H, Yang S, Lee C, Hsueh Y, Huang J, Chang C. Differences in change of post-operative antioxidant levels between laser-assisted lenticule extraction and femtosecond laser in situ keratomileusis. J Cell Mol Med 2024; 28:e18069. [PMID: 38051678 PMCID: PMC10826428 DOI: 10.1111/jcmm.18069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 10/31/2023] [Accepted: 11/22/2023] [Indexed: 12/07/2023] Open
Abstract
To evaluate the change of total antioxidant capacity (TAC) and ascorbic acid (AA) between femtosecond laser in situ keratomileusis (FS-LASIK) and laser-assisted lenticule extraction (LALEX). A prospective non-randomized study was conducted, and 33 and 75 eyes that had undergone FS-LASIK or LALEX surgeries were enrolled, respectively. The tear films near corneal incisions were collected, and the concentrations of TAC and AA were determined. The generalized linear mixed model was adopted to calculate the adjusted odds ratio (aOR) with 95% confidence interval (CI) of TAC and AA between the two groups. The AA reduction was significant 1 month after the LALEX and FS-LASIK procedures (both p < 0.05), and the decrement in AA level was significantly larger in the FS-LASIK group compared to the LALEX group (p = 0.0002). In the subgroup analysis, the LALEX group demonstrated a lower decrement in TAC level in the individuals with dry eye disease (DED) than the FS-LASIK group (p = 0.0424), and the LALEX group demonstrated a significantly lower AA decrement in the participants with high myopia (p = 0.0165) and DED (p = 0.0043). The LALEX surgery causes lesser AA decrement compared to FS-LASIK surgery especially for the patients with DED.
Collapse
Affiliation(s)
- Hung‐Chi Chen
- Department of OphthalmologyChang Gung Memorial HospitalLinkouTaiwan
- Department of MedicineChang Gung University College of MedicineTaoyuanTaiwan
- Center for Tissue EngineeringChang Gung Memorial HospitalLinkouTaiwan
| | - Shun‐Fa Yang
- Institute of Medicine, Chung Shan Medical UniversityTaichungTaiwan
- Department of Medical ResearchChung Shan Medical University HospitalTaichungTaiwan
| | - Chia‐Yi Lee
- Institute of Medicine, Chung Shan Medical UniversityTaichungTaiwan
- Nobel Eye InstituteTaipeiTaiwan
- Department of Ophthalmology, Jen‐Ai Hospital Dali BranchTaichungTaiwan
| | - Yi‐Jen Hsueh
- Department of OphthalmologyChang Gung Memorial HospitalLinkouTaiwan
- Center for Tissue EngineeringChang Gung Memorial HospitalLinkouTaiwan
| | - Jing‐Yang Huang
- Department of Medical ResearchChung Shan Medical University HospitalTaichungTaiwan
| | - Chao‐Kai Chang
- Nobel Eye InstituteTaipeiTaiwan
- Department of OptometryDa‐Yeh UniversityChunghuaTaiwan
| |
Collapse
|
5
|
Jiao YD, Yan Z, Zhao TQ, Zhao HX. Comparison of errors in ablation depth calculation after myopic femtosecond laser in situ keratomileusis in patients with different degrees of myopia: a prospective study. BMC Ophthalmol 2023; 23:453. [PMID: 37957578 PMCID: PMC10642044 DOI: 10.1186/s12886-023-03200-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 11/06/2023] [Indexed: 11/15/2023] Open
Abstract
BACKGROUND To investigate the difference between the predicted preoperative corneal ablation depth and the measured ablation depth for femtosecond laser in situ keratomileusis (FS-LASIK) in patients with different degrees of myopia, and to analyze the source of the difference. METHODS A total of 55 patients (109 eyes) were included in this study. Multiple logistics regression was applied to analyze the sources affecting postoperative refractive outcomes. The difference between the preoperative predicted corneal ablation depth and the 1-day postoperative ablation depth in patients with different degrees of myopia was explored using linear regression. Corneal biomechanical parameters influencing error in ablation depth calculation were examined using multiple linear regression. RESULTS One hundred and nine eyes were divided into low to moderate myopia (55 eyes, myopia of 6 D or less), high myopia (45 eyes, myopia ranging from 6 D to a maximum of 9 D), and very high myopia group (9 eyes, myopia greater than 9 D) based on preoperative refractive error (spherical equivalent). Postoperative visual outcomes were comparable among the three groups of patients, with no significant difference in uncorrected visual acuity (UCVA). We did find notable disparities in spherical equivalent (SE) and central corneal thickness (CCT) in patients with different degrees of myopia at 1 day postoperatively (all p < 0.001). Logistic regression analysis showed that error in ablation depth calculation was an independent risk factor for refractive outcomes one day after surgery (OR = 1.689, 95% CI: 1.366 - 2.089). There was a substantial discrepancy in error in ablation depth calculation at 1 day postoperatively between the three groups. The measured ablation depth of the laser platform was lower than the predicted ablation depth in the low to moderate myopia and very high myopia groups, but the opposite was true in the high myopia group. Pre-operative SE (p < 0.001) and corneal front minimum radius of curvature (Front Rmin) (p = 0.007) obviously influenced the error in ablation depth calculation. CONCLUSIONS Error in ablation depth calculation values vary significantly between patients with different degrees of myopia and correlate highly with preoperative SE and Front Rmin. At the same time, the available evidence suggests that error in ablation depth calculation is an influential factor in postoperative refractive status, so it is imperative to control error in ablation depth calculation.
Collapse
Affiliation(s)
- Yi-Dian Jiao
- Department of PRK Center, the Affiliated Hospital of Inner Mongolia Medical University, Tongdao North Street 1, Hohhot, 010050, China
| | - Zhi Yan
- School of Medical Laboratory, Tianjin Medical University, Guangdong Road, Tianjin, 300203, China
| | - Tian-Qi Zhao
- Department of PRK Center, the Affiliated Hospital of Inner Mongolia Medical University, Tongdao North Street 1, Hohhot, 010050, China
| | - Hai-Xia Zhao
- Department of PRK Center, the Affiliated Hospital of Inner Mongolia Medical University, Tongdao North Street 1, Hohhot, 010050, China.
| |
Collapse
|
6
|
Zhou N, Chen X, Yin N. Effect of corneal flap thickness on opaque bubble layer formation in Visumax FS-LASIK using GEE analysis. Heliyon 2023; 9:e21547. [PMID: 37964822 PMCID: PMC10641232 DOI: 10.1016/j.heliyon.2023.e21547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 10/20/2023] [Accepted: 10/23/2023] [Indexed: 11/16/2023] Open
Abstract
Introduction This study aimed to investigate two types of corneal flap thickness on opaque bubble layer (OBL) formation in Visumax femtosecond laser-assisted stromal for situ keratomileusis (FS-LASIK). Methods This retrospective study analyzed 203 eyes of 103 patients (32 men and 71 women) who underwent Visumax FS-LASIK between January 2020 and June 2020, and according to corneal flap thickness, they were divided into the 100-μm group (64 eyes) and the 110-μm group (139 eyes). Anterior-segment examination revealed no abnormal findings. Preoperatively, intraocular pressure (IOP), central corneal thickness (CCT), residual stromal thickness (RST), spherical power, cylindrical power, flat keratometry (K1), steep keratometry (K2), and biomechanical parameters including deformation amplitude (DA) ratio, Integrated Radius, stiffness parameter at first applanation (SP-A1), and Ambrosio relational thickness to the horizontal profile (ARTh) were evaluated. Primary outcomes were the incidence of OBL formation in the two groups compared by the Chi-square test and the correlation between the incidence of OBL and the above preoperative data by Spearman's Rho test. Secondary outcomes were the comparisons corrected by the generalized estimating equation (GEE) model. Results The incidence of OBL formation in the 100-μm group was 59.4 %, which was higher than that in the 110-μm group (23.0 %) with a significant difference (χ2 = 25.635, P < 0.001). The thinner corneal flap thickness (r = -0.355, P < 0.001) and higher spherical power (r = -0.142, P < 0.05) correlated with OBL formation. Higher K1 (r = 0.217, P < 0.01) and K2 (r = 0.198, P < 0.01) also correlated with OBL formation. The results of the GEE correction analysis showed higher rates of OBL formation in the 100-μm group (odds ratio [OR] = 4.704, 95 % CI 1.681-13.161, P < 0.01). Conclusions OBL was more likely to occur with the 100-μm corneal flap than with the 110-μm corneal flap in Visumax FS-LASIK. The risk of OBL formation in the 100-μm group was 4.704 times higher than that in the 110-μm group.
Collapse
Affiliation(s)
- Na Zhou
- Department of Refractive Surgery, Dongguan Aier Eye Hospital, China
| | - Xiaobei Chen
- Department of Refractive Surgery, Dongguan Aier Eye Hospital, China
| | - Na Yin
- Department of Refractive Surgery, Dongguan Aier Eye Hospital, China
| |
Collapse
|
7
|
Lu X, Fan Y, Liu Z, Qiu X, Shi Q, Gao N, Mi S, Pei C. Comparison of planned versus achieved central corneal stromal thickness reduction in SMILE versus FS-LASIK: a retrospective study. Sci Rep 2023; 13:9956. [PMID: 37340090 DOI: 10.1038/s41598-023-37143-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Accepted: 06/16/2023] [Indexed: 06/22/2023] Open
Abstract
Accuracy of planned corneal stromal thickness (CST) reduction is essential to the safety of laser vision correction. This study was to compare the accuracy of the planned central CST reduction in small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK). A total of 77 patients (43 for SMILE, 34 for FS-LASIK using Custom-Q algorithm) were included in this retrospective study. At postoperative 6-18 months, the central CST reduction was overestimated by 18.49 ± 6.42 μm in the SMILE group (P < 0.001) and underestimated by 2.56 ± 7.79 μm in the FS-LASIK group (P = 0.064). The planned-achieved difference (PAD) of central CST reduction was positively correlated with preoperative manifest refraction spherical equivalent (MRSE) and with planned central CST reduction in both groups. When calculated by manifest refraction (MR) without nomogram adjustment, the central CST reduction was overestimated by 11.14 ± 6.53 μm in the SMILE group and underestimated by 2.83 ± 7.39 μm in the FS-LASIK group. The PAD of central CST reduction without nomogram was significantly narrowed in SMILE and maintained in FS-LASIK, suggesting estimation using MR without nomogram adjustment may be feasible for SMILE and FS-LASIK in clinical practice.
Collapse
Affiliation(s)
- Xueqing Lu
- Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, 710061, Shaanxi, China
| | - Yimeng Fan
- Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, 710061, Shaanxi, China
| | - Zhao Liu
- Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, 710061, Shaanxi, China.
| | - Xuanyu Qiu
- Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, 710061, Shaanxi, China
| | - Qiang Shi
- Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, 710061, Shaanxi, China
| | - Ning Gao
- Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, 710061, Shaanxi, China
| | - Shengjian Mi
- Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, 710061, Shaanxi, China
| | - Cheng Pei
- Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, 710061, Shaanxi, China
| |
Collapse
|
8
|
He Y, Ma BS, Zeng JH, Ma DJ. Corneal optical density: Structural basis, measurements, influencing factors, and roles in refractive surgery. Front Bioeng Biotechnol 2023; 11:1144455. [PMID: 37091331 PMCID: PMC10117965 DOI: 10.3389/fbioe.2023.1144455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2023] [Accepted: 03/29/2023] [Indexed: 04/08/2023] Open
Abstract
The cornea is the main refractive medium of the human eye, and its clarity is critical to visual acuity. Corneal optical density (COD) is an important index to describe corneal transparency. Intact corneal epithelial and endothelial cells, regular arrangement of collagen fibers in the stroma, and normal substance metabolism are all integral for the cornea to maintain its transparency. In the last two decades, the Pentacam Scheimpflug imaging system has emerged as a breakthrough for the measurement of COD (also called corneal densitometry). It has been found that a wide variety of factors such as age, refractive status, and corneal diseases can affect COD. Different corneal refractive surgery methods also change COD in different corneal regions and layers and affect visual acuity following the surgery. Thus, COD has gradually become a significant indicator to evaluate corneal health, one on which the attention of clinicians has been increasingly focused.
Collapse
Affiliation(s)
- Ye He
- Changsha Aier Eye Hospital, Changsha, China
| | - Bo-Sheng Ma
- Department of Ophthalmology, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Jun-Hao Zeng
- Xiangya School of Medicine, Central South University, Changsha, China
| | - Dai-Jin Ma
- Changsha Aier Eye Hospital, Changsha, China
- *Correspondence: Dai-Jin Ma,
| |
Collapse
|
9
|
Ma KK, Manche EE. Patient-reported quality of vision in a prospective randomized contralateral-eye trial comparing LASIK and small-incision lenticule extraction. J Cataract Refract Surg 2023; 49:348-353. [PMID: 36539217 DOI: 10.1097/j.jcrs.0000000000001127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022]
Abstract
PURPOSE To compare patient-reported quality of vision and visual symptoms in participants undergoing laser in situ keratomileusis (LASIK) and small-incision lenticule extraction (SMILE). SETTING Byers Eye Institute, Stanford University, Palo Alto, California. DESIGN Prospective randomized contralateral-eye clinical trial. METHODS Patients with myopia were randomized to receive wavefront-guided femtosecond LASIK in one eye and SMILE in the fellow eye. Participants reported the presence and severity of adverse visual symptoms through the Patient-Reported Outcomes With Laser In Situ Keratomileusis questionnaire and reported which eye had better vision at the preoperative and the postoperative 1-month, 3-month, 6-month, and 12-month visits. RESULTS 80 eyes of 40 participants were treated. There was no difference in the presence or severity of double vision, glare, halos, or starbursts between eyes that underwent LASIK or SMILE at each visit ( P ≥ .85 for each comparison). Scaled scores for the presence of visual symptoms improved from the preoperative visit to the postoperative month 12 visit for double vision (88 vs 97, P = .03), glare (77 vs 92, P = .02), halos (68 vs 87, P < .01), and starbursts (60 vs 86, P < .01). At the postoperative month 12 visit, 17 (46%) of 37 participants preferred the vision from the eye that underwent LASIK compared with 7 (19%) of 37 who underwent SMILE. The preferred eye was correlated with uncorrected distance visual acuity ( r = 0.52, P < .01). CONCLUSIONS Rates of visual symptoms were similar for LASIK and SMILE, and visual symptoms improved with time. More patients preferred vision from the eye that underwent LASIK compared with SMILE.
Collapse
Affiliation(s)
- Kevin K Ma
- From the Department of Ophthalmology, Byers Eye Institute, Stanford University School of Medicine, Palo Alto, California
| | | |
Collapse
|
10
|
Corneal Stromal Densitometry Evolution in a Clinical Model of Cellular Therapy for Advanced Keratoconus. Cornea 2023; 42:332-343. [PMID: 36256440 DOI: 10.1097/ico.0000000000003152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 08/12/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE The aim of this study was to report the corneal densitometry (CD) evolution studied by Scheimpflug tomography, anterior segment optical coherence tomography (AS-OCT), and confocal microscopy changes, in patients with advanced keratoconus included in a clinical experience of advanced cell therapy using autologous humans adipose-derived adult stem cells (ADASCs) and corneal decellularized and ADASCs-recellularized human donor corneal laminas. METHODS This study is an interventional prospective, consecutive, randomized, comparative series of cases. Fourteen patients with keratoconus were randomly distributed into 3 groups for 3 types of surgical interventions: group 1 (G-1), autologous ADASC implantation (n = 5); group 2 (G-2), decellularized human corneal stroma (n = 5); and group 3 (G-3), autologous ADASCs + decellularized human corneal stroma (n = 4). Participants were assessed with Scheimpflug-based Oculus Pentacam CD module, AS-OCT (Visante; Carl Zeiss), and confocal microscopy (HRT3 RCM Heidelberg). RESULTS A significant improvement of 1 to 2 logMAR lines in all visual parameters in the 3 groups was obtained. The central and total CD were statistically significantly higher in G-2 compared with G-1 and G-3 compared with G-1 at the studied annular zones centered on the corneal apex (0-2, 2-6, and 6-10 mm). There was statistical significance higher in G-3 compared with G-2 at the central corneal stroma at 0-2 and 2-6 mm. The confocal microscopy findings and the AS-OCT reflected the densitometry changes. CONCLUSIONS The intrastromal implantation of ADASCs produced very subtle changes in CD at the level of the central corneal stroma. However, the intrastromal implantation of decellularized corneal laminas increases it slightly, but with lower values than the implantation of recellularized laminas with ADASCs.
Collapse
|
11
|
Canto-Cerdan M, El Bahrawy M, Alió JL, Casanova L, García MJ, Al-Amri SAJ, Cavas F, Alió Del Barrio JL. Corneal Epithelium Thickness and Refractive Changes After Myopic Laser Corneal Refractive Surgery. J Refract Surg 2022; 38:602-608. [PMID: 36098392 DOI: 10.3928/1081597x-20220718-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the postoperative changes in corneal epithelium thickness and refractive power after femtosecond laser-assisted laser in situ keratomileusis (LASIK) and small incision lenticule extraction (SMILE) for myopia correction using anterior segment optical coherence tomography (OCT) with an integrated Placido disc topographer. METHODS The VisuMax 500-kHz femtosecond laser (Carl Zeiss Meditec AG) and Amaris 750 excimer laser (SCHWIND eye-tech-solutions) were used. Central, paracentral, and 6-mm epithelial thickness values were obtained, and the change in the value of epithelial thickness was calculated. Changes in the refractive power of the epithelium were also evaluated. The repeatability of this new measurement was also analyzed using the intraclass correlation (ICC). The total follow-up period was 6 months. RESULTS A total of 77 LASIK eyes were matched with 77 SMILE eyes. Mean spherical equivalent was -3.92 ± 1.67 diopters (D) for LASIK versus -4.02 ± 1.63 D for SMILE (P = .356). Epithelial thickness parameters significantly and equally thickened in both types of surgery. The change in the value of epithelial thickness was positively correlated with spherical aberration. Analysis of the refractive power of the corneal epithelial layer (ICC > 0.70) showed a tendency for the postoperative myopization of the refractive component of this layer (-0.11 D for SMILE and -0.53 D for LASIK at 3 mm) and an increase in its cylinder and aberrometry. Increasing postoperative spherical aberration and epithelial thickness increased myopization of the epithelial refractive sphere (P < .05). CONCLUSIONS Corneal epithelium thickens similarly after LASIK and SMILE, being slightly higher after SMILE. This correlates with the induced spherical aberration. Corneal epithelium thickening induces myopization of its refractive power, which accounts for a slight regression of the net refractive power change on the treated cornea. [J Refract Surg. 2022;38(9):602-608.].
Collapse
|
12
|
Lwowski C, Voigt A, Van Keer K, Kohnen T. Corneal Lenticule Creation Using a New Solid-State Femtosecond Laser Measured by Spectral Domain OCT in a Porcine Eye Model. Transl Vis Sci Technol 2022; 11:20. [PMID: 35731540 PMCID: PMC9233285 DOI: 10.1167/tvst.11.6.20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To determine the accuracy and precision of corneal lenticule creation with a new solid-state femtosecond laser in a porcine eye model. Methods Corneal lenticule creation was performed using a new solid-state femtosecond laser on 60 porcine eyes with 10 subgroups. Optical coherence tomography images were acquired immediately after laser treatment. Cap thickness (CT), cap diameter (CD), and lenticule thickness (LT) were measured manually by three independent readers. Additionally, CT and LT were measured by an automated algorithm (aLT, aCT). Results Measured LT was significantly greater than the intended LT (average difference 14.3 ± 5.6 µm, P < 0.001). aLT was closer but still significantly different from the intended LT (-2.9 ± 5.8 µm, P < 0.001). Measured CT showed no significant difference from the intended CT (2.6 ± 13.3, P = 0.145). aCT was significantly smaller compared to the intended CT (-9.6 ± 13.6, P < 0.001). Measured CD was significantly smaller compared to the intended CD (-0.21 ± 0.20 mm, P < 0.001). All lenticules were cut as planned with no laser-related complications. Conclusions This new solid-state femtosecond laser used in our trial provides corneal lenticule creation in a porcine eye model comparable to other established systems. However, measuring those lenticules in the provided setting seems too challenging even when using semiautomated algorithms, which seems to be due to the experimental setting of the trial. Translational Relevance This trial shows the precision and repeatability of corneal cuts performed by a new femtosecond laser that could translate to refractive corneal lenticule surgery.
Collapse
Affiliation(s)
- Christoph Lwowski
- Department of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
| | - Anna Voigt
- Department of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
| | - Karel Van Keer
- Department of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany.,Department of Ophthalmology, University Hospitals Leuven, Leuven, Belgium
| | - Thomas Kohnen
- Department of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
| |
Collapse
|
13
|
Luo Y, He S, Chen P, Yao H, He A, Li Y, Qiu J, Lan M, Zhuang J, Yu K. Predictability of Central Corneal Stromal Reduction After SMILE and FS-LASIK for High Myopia Correction: A Prospective Randomized Contralateral Eye Study. J Refract Surg 2022; 38:90-97. [DOI: 10.3928/1081597x-20211112-01] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|