1
|
Hallum LE, Cloherty SL. Harms associated with retinal implantation of a stimulating electrode array to treat outer-retinal degeneration: a systematic review and meta-analysis of safety. PROGRESS IN BIOMEDICAL ENGINEERING (BRISTOL, ENGLAND) 2024; 7:012001. [PMID: 39655855 DOI: 10.1088/2516-1091/ad811e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 09/27/2024] [Indexed: 12/18/2024]
Abstract
Retinal implantation of an electrode array is an emerging treatment for vision loss caused by outer-retinal degeneration. This article collects and analyses harms associated with the treatment reported in the peer-reviewed literature, thus enabling informed decision-making by patients, clinicians, researchers, engineers, and policymakers. We searched MEDLINE, Embase, and clinical trials registries for peer-reviewed journal articles reporting harms outcomes. We extracted data from articles including study design, definitions of 'serious adverse event', and timing of adverse events. We applied the McMaster tool to these articles to assess the risk of bias in harms assessment and reporting. Our searches returned 585 abstracts. We reviewed the full text of 59 articles describing 11 different devices. McMaster scores ranged from 3 to 12 (maximum 15; higher scores indicate less risk). We compiled a comprehensive list of all serious and non-serious adverse events associated with retinal implantation. Several harms were common across devices. Our meta-analysis showed that serious adverse events are log-uniformly distributed throughout follow-up. Improved reporting and further clinical studies are needed to develop a reliable safety profile of retinal implantation. Our findings will help guide the design, conduct, and reporting of future clinical trials of retinal implantation and other emerging treatments for vision loss. (PROSPERO registration: CRD42022308123.).
Collapse
Affiliation(s)
- Luke E Hallum
- Faculty of Engineering, University of Auckland, Auckland, New Zealand
| | | |
Collapse
|
2
|
Nadolskis L, Turkstra LM, Larnyo E, Beyeler M. Aligning Visual Prosthetic Development With Implantee Needs. Transl Vis Sci Technol 2024; 13:28. [PMID: 39570616 PMCID: PMC11585069 DOI: 10.1167/tvst.13.11.28] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Accepted: 10/17/2024] [Indexed: 11/22/2024] Open
Abstract
Purpose Visual prosthetics are a promising assistive technology for vision loss, yet research often overlooks the human aspects of this technology. While previous studies focus on the perceptual experiences or attitudes of implant recipients (implantees), a systematic account of how current implants are being used in everyday life is still lacking. Methods We interviewed six recipients of the most widely used visual implants (Argus II and Orion) and six leading researchers in the field. Through thematic analyses, we explored the daily usage of these implants by implantees and compared their responses to the expectations of researchers. We also sought implantees' input on desired features for future versions, aiming to inform the development of the next generation of implants. Results Although implants are designed to facilitate various daily activities, we found that implantees use them less frequently than researchers expect. This discrepancy primarily stems from issues with usability and reliability, with implantees finding alternative methods to accomplish tasks, reducing the need to rely on the implant. For future implants, implantees emphasized the desire for improved vision, smart integration, and increased independence. Conclusions Our study reveals a significant gap between researcher expectations and implantee experiences with visual prostheses. Although limited by access to a small population of implantees, this study highlights the importance of focusing future research on usability and real-world applications. Translational Relevance This retrospective qualitative study advocates for a better alignment between technology development and implantee needs to enhance clinical relevance and practical utility of visual prosthetics.
Collapse
Affiliation(s)
- Lucas Nadolskis
- Interdepartmental Graduate Program in Dynamical Neuroscience, University of California, Santa Barbara, Santa Barbara, CA, USA
| | - Lily M. Turkstra
- Department of Psychological & Brain Sciences, University of California, Santa Barbara, Santa Barbara, CA, USA
| | - Ebenezer Larnyo
- Center for Black Studies Research, University of California, Santa Barbara, Santa Barbara, CA, USA
| | - Michael Beyeler
- Department of Psychological & Brain Sciences, University of California, Santa Barbara, Santa Barbara, CA, USA
- Department of Computer Science, University of California, Santa Barbara, Santa Barbara, CA, USA
| |
Collapse
|
3
|
Nadolskis LG, Turkstra LM, Larnyo E, Beyeler M. Aligning visual prosthetic development with implantee needs. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2024:2024.03.12.24304186. [PMID: 38559196 PMCID: PMC10980134 DOI: 10.1101/2024.03.12.24304186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Purpose Visual prosthetics are a promising assistive technology for vision loss, yet research often overlooks the human aspects of this technology. While previous studies focus on the perceptual experiences or attitudes of implant recipients (implantees) , a systematic account of how current implants are being used in everyday life is still lacking. Methods We interviewed six recipients of the most widely used visual implants (Argus II and Orion) and six leading researchers in the field. Through thematic analyses, we explored the daily usage of these implants by implantees and compared their responses to the expectations of researchers. We also sought implantees' input on desired features for future versions, aiming to inform the development of the next generation of implants. Results Although implants are designed to facilitate various daily activities, we found that implantees use them less frequently than researchers expect. This discrepancy primarily stems from issues with usability and reliability, with implantees finding alternative methods to accomplish tasks, reducing the need to rely on the implant. For future implants, implantees emphasized the desire for improved vision, smart integration, and increased independence. Conclusions Our study reveals a significant gap between researcher expectations and implantee experiences with visual prostheses. Although limited by access to a small population of implantees, this study highlights the importance of focusing future research on usability and real-world applications. Translational relevance This retrospective qualitative study advocates for a better alignment between technology development and implantee needs to enhance clinical relevance and practical utility of visual prosthetics.
Collapse
Affiliation(s)
- Lucas G. Nadolskis
- Interdepartmental Graduate Program in Dynamical Neuroscience, University of California, Santa Barbara
| | - Lily M. Turkstra
- Department of Psychological & Brain Sciences, University of California, Santa Barbara
| | - Ebenezer Larnyo
- Center for Black Studies Research, University of California, Santa Barbara
| | - Michael Beyeler
- Department of Psychological & Brain Sciences, University of California, Santa Barbara
- Department of Computer Science, University of California, Santa Barbara
| |
Collapse
|
4
|
Yoo Y, Cha S, Goo YS. Comparison of modulation efficiency between normal and degenerated primate retina. Front Cell Dev Biol 2024; 12:1419007. [PMID: 39144253 PMCID: PMC11322106 DOI: 10.3389/fcell.2024.1419007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Accepted: 07/10/2024] [Indexed: 08/16/2024] Open
Abstract
With electrical stimulation, retinal prostheses bypass dysfunctional photoreceptors and activate the surviving bipolar or retinal ganglion cells (RGCs). Therefore, the effective modulation of RGCs is crucial for developing retinal prostheses. Substantial research has been performed on the ability of an electrical stimulus to generate a reliable RGC response. However, different experimental conditions show varying levels of how well the electrical stimulation evokes RGC spikes. Therefore, in this study, we attempted to extract an indicator to understand how the electrical stimulation effectively evokes RGC spikes. Six cynomolgus monkeys were used: three as controls and three as an N-methyl-N-nitrosourea (MNU)-induced retinal degeneration model. The retinal recordings were performed using 8 × 8 multi-electrode arrays (MEAs). Electrical stimulation consisted of symmetrical biphasic pulses of varying amplitudes and durations. The number of stimulation conditions that resulted in significantly higher post-stimulation firing rates than pre-stimulus firing rates was defined as the modulation efficiency ratio (MER). The MER was significantly lower in degenerated retinas than in normal retinas. We investigated the relationship between the variables and the MER in normal and degenerated primate RGCs. External variables, such as duration and inter-electrode distance, and internal variables, such as average firing rates and statistics (mean, standard deviation, and coefficient of variation [CV]) of inter-spike intervals (ISIs) of spontaneous spikes, were used. External variables had similar effects on MER in normal and degenerated RGCs. In contrast, internal variables affected MER differently in normal and degenerated RGCs. While in normal RGCs, they were not related to MER, in degenerated RGCs, the mean ISIs were positively correlated with MER, and the CV of ISIs was negatively correlated with MER. The most important variable affecting MER was the mean ISI. A shorter ISI indicates hyperactive firing in the degenerated retina, which prevents electrical stimulation from evoking more RGCs. We believe that this hyperactivity in degenerated retinas results in a lower MER than that in the normal retina. Our findings can be used to optimize the selection of stimulation channels for in vitro MEA experiments and practical calibration methods to achieve higher efficiency when testing retinal prostheses.
Collapse
Affiliation(s)
- Yongseok Yoo
- School of Computer Science and Engineering, Soongsil University, Seoul, Republic of Korea
| | - Seongkwang Cha
- Department of Physiology, College of Medicine, Chungbuk National University, Cheongju, Republic of Korea
| | - Yong Sook Goo
- Department of Physiology, College of Medicine, Chungbuk National University, Cheongju, Republic of Korea
- Biomedical Research Institute, Chungbuk National University Hospital, Cheongju, Republic of Korea
| |
Collapse
|
5
|
Schulz A, Knoll T, Jaeger T, Le Harzic R, Stracke F, Wien SL, Olsommer Y, Meiser I, Wagner S, Rammensee M, Kurz O, Klesy S, Sermeus L, Julich-Haertel H, Schweitzer Y, Januschowski K, Velten T, Szurman P. Photovoltaic, wireless wide-field epiretinal prosthesis to treat retinitis pigmentosa. Acta Ophthalmol 2024. [PMID: 38923194 DOI: 10.1111/aos.16733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 06/11/2024] [Indexed: 06/28/2024]
Abstract
PURPOSE To develop and evaluate a photovoltaic, wireless wide-field epiretinal prosthesis for the treatment of retinitis pigmentosa. METHODS A mosaic array of thinned silicon-based photodiodes with integrated thin-film stimulation electrodes was fabricated with a flexible polyimide substrate film to form a film-based miniaturized electronic system with wireless optical power and signal transmission and integrated electrostimulation. Manufactured implants were characterized with respect to their optoelectronic performance and biocompatibility following DIN EN ISO 10993. RESULTS A 14 mm diameter prosthesis containing 1276 pixels with a maximum sensitivity at a near infrared wavelength of 905 nm and maximized stimulation current density 30-50 μm below the electrodes was developed for direct activation of retinal ganglion cells during epiretinal stimulation. Fabricated prostheses demonstrated mucosal tolerance and the preservation of both metabolic activity, proliferation and membrane integrity of human fibroblasts as well as the retinal functions of bovine retinas. Illumination of the prosthesis, which was placed epiretinally on an isolated perfused bovine retina, with infrared light resulted in electrophysiological recordings reminiscent of an a-wave (hyperpolarization) and b-wave (depolarization). CONCLUSIONS A photovoltaic, wireless wide-field epiretinal prosthesis for the treatment of retinitis pigmentosa using near infrared light for signal transmission was designed, manufactured and its biocompatibility and functionality demonstrated in vitro and ex vivo.
Collapse
Affiliation(s)
- André Schulz
- Eye Clinic Sulzbach, Knappschaft Hospital Saar, Sulzbach, Germany
- Klaus Heimann Eye Research Institute, Sulzbach, Germany
| | - Thorsten Knoll
- Fraunhofer Institute for Biomedical Engineering IBMT, Sulzbach, Germany
| | | | - Ronan Le Harzic
- Fraunhofer Institute for Biomedical Engineering IBMT, Sulzbach, Germany
| | - Frank Stracke
- Fraunhofer Institute for Biomedical Engineering IBMT, Sulzbach, Germany
| | - Sascha L Wien
- Fraunhofer Institute for Biomedical Engineering IBMT, Sulzbach, Germany
| | - Yves Olsommer
- Fraunhofer Institute for Biomedical Engineering IBMT, Sulzbach, Germany
| | - Ina Meiser
- Fraunhofer Institute for Biomedical Engineering IBMT, Sulzbach, Germany
| | - Sylvia Wagner
- Fraunhofer Institute for Biomedical Engineering IBMT, Sulzbach, Germany
| | | | | | | | - Loic Sermeus
- Eye Clinic Sulzbach, Knappschaft Hospital Saar, Sulzbach, Germany
| | - Henrike Julich-Haertel
- Eye Clinic Sulzbach, Knappschaft Hospital Saar, Sulzbach, Germany
- Klaus Heimann Eye Research Institute, Sulzbach, Germany
| | | | - Kai Januschowski
- Eye Clinic Sulzbach, Knappschaft Hospital Saar, Sulzbach, Germany
- Klaus Heimann Eye Research Institute, Sulzbach, Germany
| | - Thomas Velten
- Fraunhofer Institute for Biomedical Engineering IBMT, Sulzbach, Germany
| | - Peter Szurman
- Eye Clinic Sulzbach, Knappschaft Hospital Saar, Sulzbach, Germany
- Klaus Heimann Eye Research Institute, Sulzbach, Germany
| |
Collapse
|
6
|
Carleton M, Oesch NW. Asymmetric Activation of ON and OFF Pathways in the Degenerated Retina. eNeuro 2024; 11:ENEURO.0110-24.2024. [PMID: 38719453 PMCID: PMC11097263 DOI: 10.1523/eneuro.0110-24.2024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 04/15/2024] [Accepted: 04/21/2024] [Indexed: 05/18/2024] Open
Abstract
Retinal prosthetics are one of the leading therapeutic strategies to restore lost vision in patients with retinitis pigmentosa and age-related macular degeneration. Much work has described patterns of spiking in retinal ganglion cells (RGCs) in response to electrical stimulation, but less work has examined the underlying retinal circuitry that is activated by electrical stimulation to drive these responses. Surprisingly, little is known about the role of inhibition in generating electrical responses or how inhibition might be altered during degeneration. Using whole-cell voltage-clamp recordings during subretinal electrical stimulation in the rd10 and wild-type (wt) retina, we found electrically evoked synaptic inputs differed between ON and OFF RGC populations, with ON cells receiving mostly excitation and OFF cells receiving mostly inhibition and very little excitation. We found that the inhibition of OFF bipolar cells limits excitation in OFF RGCs, and a majority of both pre- and postsynaptic inhibition in the OFF pathway arises from glycinergic amacrine cells, and the stimulation of the ON pathway contributes to inhibitory inputs to the RGC. We also show that this presynaptic inhibition in the OFF pathway is greater in the rd10 retina, compared with that in the wt retina.
Collapse
Affiliation(s)
- Maya Carleton
- Department of Psychology, University of California San Diego, La Jolla, California 92093
| | - Nicholas W Oesch
- Department of Psychology, University of California San Diego, La Jolla, California 92093
- Department of Ophthalmology, University of California San Diego, La Jolla, California 92093
- Neuroscience Graduate Program, University of California San Diego, La Jolla, California 92093
| |
Collapse
|
7
|
Hou Y, Nanduri D, Granley J, Weiland JD, Beyeler M. Axonal stimulation affects the linear summation of single-point perception in three Argus II users. J Neural Eng 2024; 21:026031. [PMID: 38457841 PMCID: PMC11003296 DOI: 10.1088/1741-2552/ad31c4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 02/20/2024] [Accepted: 03/08/2024] [Indexed: 03/10/2024]
Abstract
Objective.Retinal implants use electrical stimulation to elicit perceived flashes of light ('phosphenes'). Single-electrode phosphene shape has been shown to vary systematically with stimulus parameters and the retinal location of the stimulating electrode, due to incidental activation of passing nerve fiber bundles. However, this knowledge has yet to be extended to paired-electrode stimulation.Approach.We retrospectively analyzed 3548 phosphene drawings made by three blind participants implanted with an Argus II Retinal Prosthesis. Phosphene shape (characterized by area, perimeter, major and minor axis length) and number of perceived phosphenes were averaged across trials and correlated with the corresponding single-electrode parameters. In addition, the number of phosphenes was correlated with stimulus amplitude and neuroanatomical parameters: electrode-retina and electrode-fovea distance as well as the electrode-electrode distance to ('between-axon') and along axon bundles ('along-axon'). Statistical analyses were conducted using linear regression and partial correlation analysis.Main results.Simple regression revealed that each paired-electrode shape descriptor could be predicted by the sum of the two corresponding single-electrode shape descriptors (p < .001). Multiple regression revealed that paired-electrode phosphene shape was primarily predicted by stimulus amplitude and electrode-fovea distance (p < .05). Interestingly, the number of elicited phosphenes tended to increase with between-axon distance (p < .05), but not with along-axon distance, in two out of three participants.Significance.The shape of phosphenes elicited by paired-electrode stimulation was well predicted by the shape of their corresponding single-electrode phosphenes, suggesting that two-point perception can be expressed as the linear summation of single-point perception. The impact of the between-axon distance on the perceived number of phosphenes provides further evidence in support of the axon map model for epiretinal stimulation. These findings contribute to the growing literature on phosphene perception and have important implications for the design of future retinal prostheses.
Collapse
Affiliation(s)
- Yuchen Hou
- Department of Computer Science, University of California, Santa Barbara, CA, United States of America
- Department of Psychological & Brain Sciences, University of California, Santa Barbara, CA, United States of America
| | - Devyani Nanduri
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America
| | - Jacob Granley
- Department of Computer Science, University of California, Santa Barbara, CA, United States of America
| | - James D Weiland
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States of America
| | - Michael Beyeler
- Department of Computer Science, University of California, Santa Barbara, CA, United States of America
- Department of Psychological & Brain Sciences, University of California, Santa Barbara, CA, United States of America
| |
Collapse
|
8
|
Hou Y, Nanduri D, Granley J, Weiland JD, Beyeler M. Axonal stimulation affects the linear summation of single-point perception in three Argus II users. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.07.21.23292908. [PMID: 37546858 PMCID: PMC10402233 DOI: 10.1101/2023.07.21.23292908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
Purpose Retinal implants use electrical stimulation to elicit perceived flashes of light ("phosphenes"). Single-electrode phosphene shape has been shown to vary systematically with stimulus parameters and the retinal location of the stimulating electrode, due to incidental activation of passing nerve fiber bundles. However, this knowledge has yet to be extended to paired-electrode stimulation. Methods We retrospectively analyzed 3548 phosphene drawings made by three blind participants implanted with an Argus II Retinal Prosthesis. Phosphene shape (characterized by area, perimeter, major and minor axis length) and number of perceived phosphenes were averaged across trials and correlated with the corresponding single-electrode parameters. In addition, the number of phosphenes was correlated with stimulus amplitude and neuroanatomical parameters: electrode-retina and electrode-fovea distance as well as the electrode-electrode distance to ("between-axon") and along axon bundles ("along-axon"). Statistical analyses were conducted using linear regression and partial correlation analysis. Results Simple regression revealed that each paired-electrode shape descriptor could be predicted by the sum of the two corresponding single-electrode shape descriptors (p < .001). Multiple regression revealed that paired-electrode phosphene shape was primarily predicted by stimulus amplitude and electrode-fovea distance (p < .05). Interestingly, the number of elicited phosphenes tended to increase with between-axon distance (p < .05), but not with along-axon distance, in two out of three participants. Conclusions The shape of phosphenes elicited by paired-electrode stimulation was well predicted by the shape of their corresponding single-electrode phosphenes, suggesting that two-point perception can be expressed as the linear summation of single-point perception. The notable impact of the between-axon distance on the perceived number of phosphenes provides further evidence in support of the axon map model for epiretinal stimulation. These findings contribute to the growing literature on phosphene perception and have important implications for the design of future retinal prostheses.
Collapse
Affiliation(s)
- Yuchen Hou
- Department of Computer Science, University of California, Santa Barbara, CA
- Department of Psychological & Brain Sciences, University of California, Santa Barbara, CA
| | - Devyani Nanduri
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI
| | - Jacob Granley
- Department of Computer Science, University of California, Santa Barbara, CA
| | - James D Weiland
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI
| | - Michael Beyeler
- Department of Computer Science, University of California, Santa Barbara, CA
- Department of Psychological & Brain Sciences, University of California, Santa Barbara, CA
| |
Collapse
|
9
|
Kish KE, Yuan A, Weiland JD. Patient-specific computational models of retinal prostheses. Sci Rep 2023; 13:22271. [PMID: 38097732 PMCID: PMC10721907 DOI: 10.1038/s41598-023-49580-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 12/09/2023] [Indexed: 12/17/2023] Open
Abstract
Retinal prostheses stimulate inner retinal neurons to create visual perception for blind patients. Implanted arrays have many small electrodes. Not all electrodes induce perception at the same stimulus amplitude, requiring clinicians to manually establish a visual perception threshold for each one. Phosphenes created by single-electrode stimuli can also vary in shape, size, and brightness. Computational models provide a tool to predict inter-electrode variability and automate device programming. In this study, we created statistical and patient-specific field-cable models to investigate inter-electrode variability across seven epiretinal prosthesis users. Our statistical analysis revealed that retinal thickness beneath the electrode correlated with perceptual threshold, with a significant fixed effect across participants. Electrode-retina distance and electrode impedance also correlated with perceptual threshold for some participants, but these effects varied by individual. We developed a novel method to construct patient-specific field-cable models from optical coherence tomography images. Predictions with these models significantly correlated with perceptual threshold for 80% of participants. Additionally, we demonstrated that patient-specific field-cable models could predict retinal activity and phosphene size. These computational models could be beneficial for determining optimal stimulation settings in silico, circumventing the trial-and-error testing of a large parameter space in clinic.
Collapse
Affiliation(s)
- Kathleen E Kish
- Biomedical Engineering, University of Michigan, Ann Arbor, 48105, USA
- BioInterfaces Institute, University of Michigan, Ann Arbor, 48105, USA
| | - Alex Yuan
- Ophthalmology and Ophthalmic Research, Cole Eye Institute, Cleveland Clinic Foundation, Cleveland, 44195, USA
| | - James D Weiland
- Biomedical Engineering, University of Michigan, Ann Arbor, 48105, USA.
- BioInterfaces Institute, University of Michigan, Ann Arbor, 48105, USA.
- Ophthalmology and Visual Science, University of Michigan, Ann Arbor, 48105, USA.
| |
Collapse
|
10
|
Lu JY, Lu G, Thomas BB, Humayun MS, Zhou Q. Ultrasound Concave 2-D Ring Array for Retinal Stimulation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:1527-1535. [PMID: 37792653 PMCID: PMC10657748 DOI: 10.1109/tuffc.2023.3321871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/06/2023]
Abstract
An ultrasound concave 2-D ring array transducer was designed for applications in visual stimulation of the retina with a long-term goal to restore vision in individuals with intact neurons but suffering blindness due to retinopathies. The array was synthesized and has a frequency of 20 MHz (0.075-mm wavelengths in water), 18-mm focal length (the curvature of the concave array), 1004 elements (with a pitch of 4.0 wavelengths), and inner and outer diameters of 9 and 14 mm, respectively. Wave patterns produced with the array at the focal distance were simulated. Results show that the wave patterns obtained can achieve a full-width-at-half-maximum (FWHM) resolution of 0.147 mm that is very close to the FWHM diffraction limit (0.136 mm). In addition, a scaled experiment at a lower frequency of 2.5 MHz was performed. The result is very close to those obtained with the simulations.
Collapse
|
11
|
Peiroten L, Zrenner E, Haq W. Artificial Vision: The High-Frequency Electrical Stimulation of the Blind Mouse Retina Decay Spike Generation and Electrogenically Clamped Intracellular Ca 2+ at Elevated Levels. Bioengineering (Basel) 2023; 10:1208. [PMID: 37892938 PMCID: PMC10604554 DOI: 10.3390/bioengineering10101208] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 10/05/2023] [Accepted: 10/13/2023] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND The electrical stimulation (stim) of retinal neurons enables blind patients to experience limited artificial vision. A rapid response outage of the stimulated ganglion cells (GCs) allows for a low visual sensation rate. Hence, to elucidate the underlying mechanism, we investigated different stim parameters and the role of the neuromodulator calcium (Ca2+). METHODS Subretinal stim was applied on retinal explants (blind rd1 mouse) using multielectrode arrays (MEAs) or single metal electrodes, and the GC activity was recorded using Ca2+ imaging or MEA, respectively. Stim parameters, including voltage, phase polarity, and frequency, were investigated using specific blockers. RESULTS At lower stim frequencies (<5 Hz), GCs responded synaptically according to the stim pulses (stim: biphasic, cathodic-first, -1.6/+1.5 V). In contrast, higher stim frequencies (≥5 Hz) also activated GCs directly and induced a rapid GC spike response outage (<500 ms, MEA recordings), while in Ca2+ imaging at the same frequencies, increased intracellular Ca2+ levels were observed. CONCLUSIONS Our study elucidated the mechanisms involved in stim-dependent GC spike response outage: sustained high-frequency stim-induced spike outage, accompanied by electrogenically clamped intracellular Ca2+ levels at elevated levels. These findings will guide future studies optimizing stim paradigms for electrical implant applications for interfacing neurons.
Collapse
Affiliation(s)
| | | | - Wadood Haq
- Neuroretinal Electrophysiology and Imaging, Institute for Ophthalmic Research, Eberhard-Karls-Universität Tübingen, 72076 Tübingen, Germany; (L.P.)
| |
Collapse
|
12
|
Kish KE, Yuan A, Weiland JD. Patient-specific computational models of retinal prostheses. RESEARCH SQUARE 2023:rs.3.rs-3168193. [PMID: 37577674 PMCID: PMC10418526 DOI: 10.21203/rs.3.rs-3168193/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
Retinal prostheses stimulate inner retinal neurons to create visual perception for blind patients. Implanted arrays have many small electrodes, which act as pixels. Not all electrodes induce perception at the same stimulus amplitude, requiring clinicians to manually establish a visual perception threshold for each one. Phosphenes created by single-electrode stimuli can also vary in shape, size, and brightness. Computational models provide a tool to predict inter-electrode variability and automate device programming. In this study, we created statistical and patient-specific field-cable models to investigate inter-electrode variability across seven epiretinal prosthesis users. Our statistical analysis revealed that retinal thickness beneath the electrode correlated with perceptual threshold, with a significant fixed effect across participants. Electrode-retina distance and electrode impedance also correlated with perceptual threshold for some participants, but these effects varied by individual. We developed a novel method to construct patient-specific field-cable models from optical coherence tomography images. Predictions with these models significantly correlated with perceptual threshold for 80% of participants. Additionally, we demonstrated that patient-specific field-cable models could predict retinal activity and phosphene size. These computational models could be beneficial for determining optimal stimulation settings in silico, circumventing the trial-and-error testing of a large parameter space in clinic.
Collapse
Affiliation(s)
| | - Alex Yuan
- Cole Eye Institute, Cleveland Clinic Foundation
| | | |
Collapse
|
13
|
Gogliettino AR, Madugula SS, Grosberg LE, Vilkhu RS, Brown J, Nguyen H, Kling A, Hottowy P, Dąbrowski W, Sher A, Litke AM, Chichilnisky EJ. High-Fidelity Reproduction of Visual Signals by Electrical Stimulation in the Central Primate Retina. J Neurosci 2023; 43:4625-4641. [PMID: 37188516 PMCID: PMC10286946 DOI: 10.1523/jneurosci.1091-22.2023] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 05/08/2023] [Accepted: 05/10/2023] [Indexed: 05/17/2023] Open
Abstract
Electrical stimulation of retinal ganglion cells (RGCs) with electronic implants provides rudimentary artificial vision to people blinded by retinal degeneration. However, current devices stimulate indiscriminately and therefore cannot reproduce the intricate neural code of the retina. Recent work has demonstrated more precise activation of RGCs using focal electrical stimulation with multielectrode arrays in the peripheral macaque retina, but it is unclear how effective this can be in the central retina, which is required for high-resolution vision. This work probes the neural code and effectiveness of focal epiretinal stimulation in the central macaque retina, using large-scale electrical recording and stimulation ex vivo The functional organization, light response properties, and electrical properties of the major RGC types in the central retina were mostly similar to the peripheral retina, with some notable differences in density, kinetics, linearity, spiking statistics, and correlations. The major RGC types could be distinguished by their intrinsic electrical properties. Electrical stimulation targeting parasol cells revealed similar activation thresholds and reduced axon bundle activation in the central retina, but lower stimulation selectivity. Quantitative evaluation of the potential for image reconstruction from electrically evoked parasol cell signals revealed higher overall expected image quality in the central retina. An exploration of inadvertent midget cell activation suggested that it could contribute high spatial frequency noise to the visual signal carried by parasol cells. These results support the possibility of reproducing high-acuity visual signals in the central retina with an epiretinal implant.SIGNIFICANCE STATEMENT Artificial restoration of vision with retinal implants is a major treatment for blindness. However, present-day implants do not provide high-resolution visual perception, in part because they do not reproduce the natural neural code of the retina. Here, we demonstrate the level of visual signal reproduction that is possible with a future implant by examining how accurately responses to electrical stimulation of parasol retinal ganglion cells can convey visual signals. Although the precision of electrical stimulation in the central retina was diminished relative to the peripheral retina, the quality of expected visual signal reconstruction in parasol cells was greater. These findings suggest that visual signals could be restored with high fidelity in the central retina using a future retinal implant.
Collapse
Affiliation(s)
- Alex R Gogliettino
- Neurosciences PhD Program, Stanford University, Stanford, California 94305
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
| | - Sasidhar S Madugula
- Neurosciences PhD Program, Stanford University, Stanford, California 94305
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Stanford School of Medicine, Stanford University, Stanford, California 94305
| | - Lauren E Grosberg
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Department of Neurosurgery, Stanford University, Stanford, California 94305
| | - Ramandeep S Vilkhu
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Department of Electrical Engineering, Stanford University, Stanford, California 94305
| | - Jeff Brown
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Department of Neurosurgery, Stanford University, Stanford, California 94305
- Department of Electrical Engineering, Stanford University, Stanford, California 94305
| | - Huy Nguyen
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
| | - Alexandra Kling
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Department of Neurosurgery, Stanford University, Stanford, California 94305
| | - Paweł Hottowy
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, 30-059, Kraków, Poland
| | - Władysław Dąbrowski
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, 30-059, Kraków, Poland
| | - Alexander Sher
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, Santa Cruz, California 95064
| | - Alan M Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, Santa Cruz, California 95064
| | - E J Chichilnisky
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Department of Neurosurgery, Stanford University, Stanford, California 94305
- Department of Electrical Engineering, Stanford University, Stanford, California 94305
- Department of Ophthalmology, Stanford University, Stanford, California 94305
| |
Collapse
|
14
|
Oh Y, Hong J, Kim J. Integrated Low-Voltage Compliance and Wide-Dynamic Stimulator Design for Neural Implantable Devices. SENSORS (BASEL, SWITZERLAND) 2023; 23:492. [PMID: 36617100 PMCID: PMC9823420 DOI: 10.3390/s23010492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 12/29/2022] [Accepted: 12/30/2022] [Indexed: 06/17/2023]
Abstract
In this study, a pulse frequency modulation (PFM)-based stimulator is proposed for use in biomedical implantable devices. Conventionally, functional electrical stimulation (FES) techniques have been used to reinforce damaged nerves, such as retina tissue and brain tissue, by injecting a certain amount of charge into tissues. Although several design methods are present for implementing FES devices, an FES stimulator for retinal implants is difficult to realize because of the chip area, which needs to be inserted in a fovea, sized 5 mm x 5 mm, and power limitations to prevent the heat generation that causes tissue damage. In this work, we propose a novel stimulation structure to reduce the compliance voltage during stimulation, which can result in high-speed and low-voltage operation. A new stimulator that is composed of a modified high-speed PFM, a 4-bit counter, a serializer, a digital controller, and a current driver is designed and verified using a DB HiTek standard 0.18 μm process. This proposed stimulator can generate a charge up to 130 nC, consumes an average power of 375 µW during a stimulation period, and occupies a total area of 700 µm × 68 µm.
Collapse
Affiliation(s)
- Yeonji Oh
- Department of Medical Science, Korea University, Seoul 02841, Republic of Korea
| | - Jonggi Hong
- Department of Health Sciences & Technology, Gachon Advanced Institute for Health Sciences & Technology, Gachon University, Incheon 21999, Republic of Korea
| | - Jungsuk Kim
- Department of Biomedical Engineering, Gachon University, Incheon 21936, Republic of Korea
| |
Collapse
|
15
|
Haq W, Basavaraju S, Speck A, Zrenner E. Nature-inspired saccadic-like electrical stimulation paradigm promotes sustained retinal ganglion cell responses by spatiotemporally alternating activation of contiguous multi-electrode patterns. J Neural Eng 2022; 19. [PMID: 36066085 DOI: 10.1088/1741-2552/ac8ad0] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 08/18/2022] [Indexed: 11/12/2022]
Abstract
Objective. Retinal electrical stimulation using multi-electrode arrays (MEAs) aims to restore visual object perception in blind patients. However, the rate and duration of the artificial visual sensations are limited due to the rapid response decay of the stimulated neurons. Hence, we investigated a novel nature-inspired saccadic-like stimulation paradigm (biomimetic) to evoke sustained retinal responses. For implementation, the macroelectrode was replaced by several contiguous microelectrodes and activated non-simultaneously but alternating topologically.Approach.MEAs with hexagonally arranged electrodes were utilized to simulate and record mouse retinal ganglion cells (RGCs). Two shapes were presented electrically using MEAs: a 6e-hexagon (six hexagonally arranged 10µm electrodes; 6e-hexagon diameter: 80µm) and a double-bar (180µm spaced, 320µm in length). Electrodes of each shape were activated in three different modes (simultaneous, circular, and biomimetic ('zig-zag')), stimulating at different frequencies (1-20 Hz).Main results.The biomimetic stimulation generated enhanced RGC responses increasing the activity rate by 87.78%. In the spatiotemporal context, the electrical representation of the 6e-hexagon produced sustained and local RGC responses (∼130µm corresponding to ∼2.5° of the human visual angle) for up to 90 s at 10 Hz stimulation and resolved the electrically presented double-bar. In contrast, during conventional simultaneous stimulation, the responses were poor and declined within seconds. Similarly, the applicability of the biomimetic mode for retinal implants (7 × 8 pixels) was successfully demonstrated. An object shape impersonating a smile was presented electrically, and the recorded data were used to emulate the implant's performance. The spatiotemporal pixel mapping of the activity produced a complete retinal image of the smile.Significance.The application of electrical stimulation in the biomimetic mode produced locally enhanced RGC responses with significantly reduced fading effects and yielded advanced spatiotemporal performance reflecting the presented electrode shapes in the mapped activity imprint. Therefore, it is likely that the RGC responses persist long enough to evoke visual perception and generate a seamless image, taking advantage of the flicker fusion. Hence, replacing the implant's macroelectrodes with microelectrodes and their activation in a topologically alternating biomimetic fashion may overcome the patient's perceptual image fading, thereby enhancing the spatiotemporal characteristics of artificial vision.
Collapse
Affiliation(s)
- Wadood Haq
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| | - Sunetra Basavaraju
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| | - Achim Speck
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| | - Eberhart Zrenner
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| |
Collapse
|
16
|
Paknahad J, Humayun M, Lazzi G. Selective Activation of Retinal Ganglion Cell Subtypes Through Targeted Electrical Stimulation Parameters. IEEE Trans Neural Syst Rehabil Eng 2022; 30:350-359. [PMID: 35130164 PMCID: PMC8904155 DOI: 10.1109/tnsre.2022.3149967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
To restore vision to the low vision, epiretinal implants have been developed to electrically stimulate the healthy retinal ganglion cells (RGCs) in the degenerate retina. Given the diversity of retinal ganglion cells as well as the difference in their visual function, selective activation of RGCs subtypes can significantly improve the quality of the restored vision. Our recent results demonstrated that with the proper modulation of the current amplitude, small D1-bistratified cells with the contribution to blue/yellow color opponent pathway can be selectively activated at high frequency (200 Hz). The computational results correlated with the clinical findings revealing the blue sensation of 5/7 subjects with epiretinal implants at high frequency. Here we further explored the impacts of alterations in pulse duration and interphase gap on the response of RGCs at high frequency. We used the developed RGCs, A2-monostratified and D1-bistratified, and examined their response to a range of pulse durations (0.1−1.2 ms) and interphase gaps (0−1 ms). We found that the use of short pulse durations with no interphase gap at high frequency increases the differential response of RGCs, offering better opportunities for selective activation of D1 cells. The presence of the interphase gap has shown to reduce the overall differential response of RGCs. We also explored how the low density of calcium channels enhances the responsiveness of RGCs at high frequency.
Collapse
|
17
|
Paknahad J, Kosta P, Bouteiller JMC, Humayun MS, Lazzi G. Mechanisms underlying activation of retinal bipolar cells through targeted electrical stimulation: a computational study. J Neural Eng 2021; 18. [PMID: 34826830 DOI: 10.1088/1741-2552/ac3dd8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Accepted: 11/26/2021] [Indexed: 11/12/2022]
Abstract
Objective. Retinal implants have been developed to electrically stimulate healthy retinal neurons in the progressively degenerated retina. Several stimulation approaches have been proposed to improve the visual percept induced in patients with retinal prostheses. We introduce a computational model capable of simulating the effects of electrical stimulation on retinal neurons. Leveraging this computational platform, we delve into the underlying mechanisms influencing the sensitivity of retinal neurons' response to various stimulus waveforms.Approach. We implemented a model of spiking bipolar cells (BCs) in the magnocellular pathway of the primate retina, diffuse BC subtypes (DB4), and utilized our multiscale admittance method (AM)-NEURON computational platform to characterize the response of BCs to epiretinal electrical stimulation with monophasic, symmetric, and asymmetric biphasic pulses.Main results. Our investigations yielded four notable results: (a) the latency of BCs increases as stimulation pulse duration lengthens; conversely, this latency decreases as the current amplitude increases. (b) Stimulation with a long anodic-first symmetric biphasic pulse (duration > 8 ms) results in a significant decrease in spiking threshold compared to stimulation with similar cathodic-first pulses (from 98.2 to 57.5µA). (c) The hyperpolarization-activated cyclic nucleotide-gated channel was a prominent contributor to the reduced threshold of BCs in response to long anodic-first stimulus pulses. (d) Finally, extending the study to asymmetric waveforms, our results predict a lower BCs threshold using asymmetric long anodic-first pulses compared to that of asymmetric short cathodic-first stimulation.Significance. This study predicts the effects of several stimulation parameters on spiking BCs response to electrical stimulation. Of importance, our findings shed light on mechanisms underlying the experimental observations from the literature, thus highlighting the capability of the methodology to predict and guide the development of electrical stimulation protocols to generate a desired biological response, thereby constituting an ideal testbed for the development of electroceutical devices.
Collapse
Affiliation(s)
- Javad Paknahad
- Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA, United States of America.,Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA, United States of America
| | - Pragya Kosta
- Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA, United States of America
| | - Jean-Marie C Bouteiller
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America
| | - Mark S Humayun
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America.,Department of Ophthalmology, University of Southern California, Los Angeles, CA, United States of America
| | - Gianluca Lazzi
- Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA, United States of America.,Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA, United States of America.,Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America.,Department of Ophthalmology, University of Southern California, Los Angeles, CA, United States of America
| |
Collapse
|
18
|
Esquenazi RB, Meier K, Beyeler M, Boynton GM, Fine I. Learning to see again: Perceptual learning of simulated abnormal on- off-cell population responses in sighted individuals. J Vis 2021; 21:10. [PMID: 34935878 PMCID: PMC8727313 DOI: 10.1167/jov.21.13.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Many forms of artificial sight recovery, such as electronic implants and optogenetic proteins, generally cause simultaneous, rather than complementary firing of on- and off-center retinal cells. Here, using virtual patients—sighted individuals viewing distorted input—we examine whether plasticity might compensate for abnormal neuronal population responses. Five participants were dichoptically presented with a combination of original and contrast-reversed images. Each image (I) and its contrast-reverse (Iʹ) was filtered using a radial checkerboard (F) in Fourier space and its inverse (Fʹ). [I * F′] + [Iʹ * F] was presented to one eye, and [I * F] + [Iʹ * F′] was presented to the other, such that regions of the image that produced on-center responses in one eye produced off-center responses in the other eye, and vice versa. Participants continuously improved in a naturalistic object discrimination task over 20 one-hour sessions. Pre-training and post-training tests suggest that performance improvements were due to two learning processes: learning to recognize objects with reduced visual information and learning to suppress contrast-reversed image information in a non–eye-selective manner. These results suggest that, with training, it may be possible to adapt to the unnatural on- and off-cell population responses produced by electronic and optogenetic sight recovery technologies.
Collapse
Affiliation(s)
| | - Kimberly Meier
- Department of Psychology, University of Washington, USA.,
| | - Michael Beyeler
- Department of Computer Science, University of California, Santa Barbara, Santa Barbara, California, USA.,Department of Psychological and Brain Sciences, University of California, Santa Barbara, Santa Barbara, California, USA.,
| | | | - Ione Fine
- Department of Psychology, University of Washington, USA.,
| |
Collapse
|
19
|
Li W, Xu Z, Wang H, Wu T. The Effect of Electrical Stimulation on the Response of Mouse Retinal Ganglion Cells. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:5704-5708. [PMID: 34892416 DOI: 10.1109/embc46164.2021.9630580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Retinal prostheses can restore the basic visual function of patients with retinal degeneration, which relies on effective electrical stimulation to evoke the physiological activities of retinal ganglion cells (RGCs). Current electrical stimulation strategies suffer from unstable effects and insufficient stimulation positions. Therefore, it is crucial to determine the optimal parameters for precise and safe electrical stimulation. Biphasic voltages (cathode-first) with a pulse width of 25 ms and different amplitudes were used to ex vivo stimulate RGCs of three wild-type (WT) mice using a commercial microelectrode array (MEA) recording system. Based on a facile and efficient spike sorting method, comprehensive statistics of RGCs response types were performed, and the influence of electrical stimulation on RGCs response status was analyzed. There were three types of RGCs response measured from the retinas of three WT mice, and the proportions were calculated to be 91.5%, 3.11% and 5.39%, respectively. This work can provide an in-depth understanding of the internal effects of electrical stimulation and RGCs response, with the potential as a useful guidance for optimizing parameters of electrical stimulation strategies in retinal prostheses.
Collapse
|
20
|
Hallum LE, Dakin SC. Retinal Implantation of Electronic Vision Prostheses to Treat Retinitis Pigmentosa: A Systematic Review. Transl Vis Sci Technol 2021; 10:8. [PMID: 34383874 PMCID: PMC8362638 DOI: 10.1167/tvst.10.10.8] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Purpose Retinitis pigmentosa (RP) is a hereditary disease causing photoreceptor degeneration and permanent vision loss. Retinal implantation of a stimulating electrode array is a new treatment for RP, but quantification of its efficacy is the subject of ongoing work. This review evaluates vision-related outcomes resulting from retinal implantation in participants with RP. Methods We searched MEDLINE and Embase for journal articles published since January 1, 2015. We selected articles describing studies of implanted participants that reported the postimplantation measurement of vision. We extracted study information including design, participants’ residual vision, comparators, and assessed outcomes. To assess the risk of bias, we used signaling questions and a target trial. Results Our search returned 425 abstracts. We reviewed the full text of 34 articles. We judged all studies to be at high risk of bias owing to the study design or experimental conduct. Regarding design, studies lacked the measures that typical clinical trials take to protect against bias (e.g., control groups and masking). Regarding experimental conduct, outcome measures were rarely comparable before and after implantation, and psychophysical methods were prone to bias (subjective, not forced choice, methods). The most common comparison found was between postimplantation visual function with the device powered off versus on. This comparison is at high risk of bias. Conclusions There is a need for high-quality evidence of efficacy of retinal implantation to treat RP. Translational Relevance For patients and clinicians to make informed choices about RP treatment, visual function restored by retinal implantation must be properly quantified and reported.
Collapse
Affiliation(s)
- Luke E Hallum
- Department of Mechanical Engineering, University of Auckland, Auckland, New Zealand
| | - Steven C Dakin
- School of Optometry and Vision Science, University of Auckland, Auckland, New Zealand
| |
Collapse
|
21
|
Kare SS, Rountree CM, Troy JB, Finan JD, Saggere L. Neuromodulation using electroosmosis. J Neural Eng 2021; 18:10.1088/1741-2552/ac00d3. [PMID: 33984848 PMCID: PMC8177066 DOI: 10.1088/1741-2552/ac00d3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 05/13/2021] [Indexed: 11/12/2022]
Abstract
Objective.Our laboratory has proposed chemical stimulation of retinal neurons using exogenous glutamate as a biomimetic strategy for treating vision loss caused by photoreceptor (PR) degenerative diseases. Although our previousin-vitrostudies using pneumatic actuation indicate that chemical retinal stimulation is achievable, an actuation technology that is amenable to microfabrication, as needed for anin-vivoimplantable device, has yet to be realized. In this study, we sought to evaluate electroosmotic flow (EOF) as a mechanism for delivering small quantities of glutamate to the retina. EOF has great potential for miniaturization.Approach.An EOF device to dispense small quantities of glutamate was constructed and its ability to drive retinal output tested in anin-vitropreparation of PR degenerate rat retina.Main results.We built and tested an EOF microfluidic system, with 3D printed and off-the-shelf components, capable of injecting small volumes of glutamate in a pulsatile fashion when a low voltage control signal was applied. With this device, we produced excitatory and inhibitory spike rate responses in PR degenerate rat retinae. Glutamate evoked spike rate responses were also observed to be voltage-dependent and localized to the site of injection.Significance.The EOF device performed similarly to a previously tested conventional pneumatic microinjector as a means of chemically stimulating the retina while eliminating the moving plunger of the pneumatic microinjector that would be difficult to miniaturize and parallelize. Although not implantable, the prototype device presented here as a proof of concept indicates that a retinal prosthetic based on EOF-driven chemical stimulation is a viable and worthwhile goal. EOF should have similar advantages for controlled dispensing of charged neurochemicals at any neural interface.
Collapse
Affiliation(s)
- Sai Siva Kare
- Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Corey M Rountree
- Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| | - John B Troy
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, United States of America
| | - John D Finan
- Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Laxman Saggere
- Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| |
Collapse
|
22
|
Abbasi B, Rizzo JF. Advances in Neuroscience, Not Devices, Will Determine the Effectiveness of Visual Prostheses. Semin Ophthalmol 2021; 36:168-175. [PMID: 33734937 DOI: 10.1080/08820538.2021.1887902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Background: Innovations in engineering and neuroscience have enabled the development of sophisticated visual prosthetic devices. In clinical trials, these devices have provided visual acuities as high as 20/460, enabled coarse navigation, and even allowed for reading of short words. However, long-term commercial viability arguably rests on attaining even better vision and more definitive improvements in tasks of daily living and quality of life. Purpose: Here we review technological and biological obstacles in the implementation of visual prosthetics. Conclusions: Research in the visual prosthetic field has tackled significant technical challenges, including biocompatibility, signal spread through neural tissue, and inadvertent activation of passing axons; however, significant gaps in knowledge remain in the realm of neuroscience, including the neural code of vision and visual plasticity. We assert that further optimization of prosthetic devices alone will not provide markedly improved visual outcomes without significant advances in our understanding of neuroscience.
Collapse
Affiliation(s)
- Bardia Abbasi
- Neuro-Ophthalmology Service, Department of Ophthalmology, Massachusetts Eye and Ear and Harvard Medical School, Boston, MA, USA
| | - Joseph F Rizzo
- Neuro-Ophthalmology Service, Department of Ophthalmology, Massachusetts Eye and Ear and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
23
|
Li W, Qin S, Lu Y, Wang H, Xu Z, Wu T. A facile and comprehensive algorithm for electrical response identification in mouse retinal ganglion cells. PLoS One 2021; 16:e0246547. [PMID: 33705406 PMCID: PMC7951861 DOI: 10.1371/journal.pone.0246547] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Accepted: 01/20/2021] [Indexed: 12/01/2022] Open
Abstract
Retinal prostheses can restore the basic visual function of patients with retinal degeneration, which relies on effective electrical stimulation to evoke the physiological activities of retinal ganglion cells (RGCs). Current electrical stimulation strategies have defects such as unstable effects and insufficient stimulation positions, therefore, it is crucial to determine the optimal pulse parameters for precise and safe electrical stimulation. Biphasic voltages (cathode-first) with a pulse width of 25 ms and different amplitudes were used to ex vivo stimulate RGCs of three wild-type (WT) mice using a commercial microelectrode array (MEA) recording system. An algorithm is developed to automatically realize both spike-sorting and electrical response identification for the spike signals recorded. Measured from three WT mouse retinas, the total numbers of RGC units and responsive RGC units were 1193 and 151, respectively. In addition, the optimal pulse amplitude range for electrical stimulation was determined to be 0.43 V-1.3 V. The processing results of the automatic algorithm we proposed shows high consistency with those using traditional manual processing. We anticipate the new algorithm can not only speed up the elaborate electrophysiological data processing, but also optimize pulse parameters for the electrical stimulation strategy of neural prostheses.
Collapse
Affiliation(s)
- Wanying Li
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Shan Qin
- Shenzhen Shekou People’s Hospital, Shenzhen, China
| | - Yijie Lu
- Shenzhen Aier Eye Hospital, Shenzhen, China
| | - Hao Wang
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zhen Xu
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- * E-mail: (TZW); (ZX)
| | - Tianzhun Wu
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- * E-mail: (TZW); (ZX)
| |
Collapse
|
24
|
Paknahad J, Loizos K, Yue L, Humayun MS, Lazzi G. Color and cellular selectivity of retinal ganglion cell subtypes through frequency modulation of electrical stimulation. Sci Rep 2021; 11:5177. [PMID: 33664347 PMCID: PMC7933163 DOI: 10.1038/s41598-021-84437-w] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 02/15/2021] [Indexed: 01/31/2023] Open
Abstract
Epiretinal prostheses aim at electrically stimulating the inner most surviving retinal cells-retinal ganglion cells (RGCs)-to restore partial sight to the blind. Recent tests in patients with epiretinal implants have revealed that electrical stimulation of the retina results in the percept of color of the elicited phosphenes, which depends on the frequency of stimulation. This paper presents computational results that are predictive of this finding and further support our understanding of the mechanisms of color encoding in electrical stimulation of retina, which could prove pivotal for the design of advanced retinal prosthetics that elicit both percept and color. This provides, for the first time, a directly applicable "amplitude-frequency" stimulation strategy to "encode color" in future retinal prosthetics through a predictive computational tool to selectively target small bistratified cells, which have been shown to contribute to "blue-yellow" color opponency in the retinal circuitry. The presented results are validated with experimental data reported in the literature and correlated with findings in blind patients with a retinal prosthetic implant collected by our group.
Collapse
Affiliation(s)
- Javad Paknahad
- grid.42505.360000 0001 2156 6853Department of Electrical Engineering, University of Southern California, Los Angeles, CA USA ,grid.42505.360000 0001 2156 6853The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA USA
| | - Kyle Loizos
- grid.42505.360000 0001 2156 6853The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA USA
| | - Lan Yue
- grid.42505.360000 0001 2156 6853Roski Eye Institute, University of Southern California, Los Angeles, CA USA
| | - Mark S. Humayun
- grid.42505.360000 0001 2156 6853Roski Eye Institute, University of Southern California, Los Angeles, CA USA ,grid.42505.360000 0001 2156 6853Departments of Ophthalmology and Biomedical Engineering, University of Southern California, Los Angeles, CA USA
| | - Gianluca Lazzi
- grid.42505.360000 0001 2156 6853Department of Electrical Engineering, University of Southern California, Los Angeles, CA USA ,grid.42505.360000 0001 2156 6853The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA USA ,grid.42505.360000 0001 2156 6853Departments of Ophthalmology and Biomedical Engineering, University of Southern California, Los Angeles, CA USA
| |
Collapse
|
25
|
Microfluidic and Microscale Assays to Examine Regenerative Strategies in the Neuro Retina. MICROMACHINES 2020; 11:mi11121089. [PMID: 33316971 PMCID: PMC7763644 DOI: 10.3390/mi11121089] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 12/03/2020] [Accepted: 12/05/2020] [Indexed: 12/15/2022]
Abstract
Bioengineering systems have transformed scientific knowledge of cellular behaviors in the nervous system (NS) and pioneered innovative, regenerative therapies to treat adult neural disorders. Microscale systems with characteristic lengths of single to hundreds of microns have examined the development and specialized behaviors of numerous neuromuscular and neurosensory components of the NS. The visual system is comprised of the eye sensory organ and its connecting pathways to the visual cortex. Significant vision loss arises from dysfunction in the retina, the photosensitive tissue at the eye posterior that achieves phototransduction of light to form images in the brain. Retinal regenerative medicine has embraced microfluidic technologies to manipulate stem-like cells for transplantation therapies, where de/differentiated cells are introduced within adult tissue to replace dysfunctional or damaged neurons. Microfluidic systems coupled with stem cell biology and biomaterials have produced exciting advances to restore vision. The current article reviews contemporary microfluidic technologies and microfluidics-enhanced bioassays, developed to interrogate cellular responses to adult retinal cues. The focus is on applications of microfluidics and microscale assays within mammalian sensory retina, or neuro retina, comprised of five types of retinal neurons (photoreceptors, horizontal, bipolar, amacrine, retinal ganglion) and one neuroglia (Müller), but excludes the non-sensory, retinal pigmented epithelium.
Collapse
|
26
|
Tanskanen JM, Ahtiainen A, Hyttinen JA. Toward Closed-Loop Electrical Stimulation of Neuronal Systems: A Review. Bioelectricity 2020; 2:328-347. [PMID: 34471853 PMCID: PMC8370352 DOI: 10.1089/bioe.2020.0028] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
Biological neuronal cells communicate using neurochemistry and electrical signals. The same phenomena also allow us to probe and manipulate neuronal systems and communicate with them. Neuronal system malfunctions cause a multitude of symptoms and functional deficiencies that can be assessed and sometimes alleviated by electrical stimulation. Our working hypothesis is that real-time closed-loop full-duplex measurement and stimulation paradigms can provide more in-depth insight into neuronal networks and enhance our capability to control diseases of the nervous system. In this study, we review extracellular electrical stimulation methods used in in vivo, in vitro, and in silico neuroscience research and in the clinic (excluding methods mainly aimed at neuronal growth and other similar effects) and highlight the potential of closed-loop measurement and stimulation systems. A multitude of electrical stimulation and measurement-based methods are widely used in research and the clinic. Closed-loop methods have been proposed, and some are used in the clinic. However, closed-loop systems utilizing more complex measurement analysis and adaptive stimulation systems, such as artificial intelligence systems connected to biological neuronal systems, do not yet exist. Our review promotes the research and development of intelligent paradigms aimed at meaningful communications between neuronal and information and communications technology systems, "dialogical paradigms," which have the potential to take neuroscience and clinical methods to a new level.
Collapse
Affiliation(s)
- Jarno M.A. Tanskanen
- BioMediTech Institute and Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Annika Ahtiainen
- BioMediTech Institute and Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Jari A.K. Hyttinen
- BioMediTech Institute and Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| |
Collapse
|
27
|
Haji Ghaffari D, Finn KE, Jeganathan VSE, Patel U, Wuyyuru V, Roy A, Weiland JD. The effect of waveform asymmetry on perception with epiretinal prostheses. J Neural Eng 2020; 17:045009. [PMID: 32590371 DOI: 10.1088/1741-2552/aba07e] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Objective Retinal prosthetic implants have helped improve vision in patients blinded by photoreceptor degeneration. Retinal implant users report improvements in light perception and performing visual tasks, but their ability to perceive shapes and letters is limited due to the low precision of retinal activation, which is exacerbated by axonal stimulation and high perceptual thresholds. A previous in vitro study in our lab used calcium imaging to measure the spatial activity of mouse retinal ganglion cells (RGCs) in response to electrical stimulation. Based on this study, symmetric anodic-first (SA) stimulation effectively avoided axonal activation and asymmetric anodic-first stimulation (AA) with duration ratios (ratio of the anodic to cathodic phase) greater than 10 reduced RGC activation thresholds significantly. Applying these novel stimulation strategies in clinic may increase perception precision and improve the overall patient outcomes. Approach We combined human subject testing and computational modeling to further examine the effect of SA and AA stimuli on perception shapes and thresholds for epiretinal stimulation of RGCs. Main results Threshold measurement in three Argus II participants indicated that AA stimulation could increase perception probabilities compared to a standard symmetric cathodic-first (SC) pulse, and this effect can be intensified by addition of an interphae gap (IPG). Our in silico RGC model predicts lower thresholds with AA and asymmetric cathodic-first (AC) stimuli compared to a SC pulse. This effect was more pronounced at shorter pulse widths. The most effective pulse for threshold reduction with short pulse durations (≤0.12 ms) was AA stimulation with small duration ratios (≤5) and long IPGs (≥2 ms). For the 0.5 ms pulse duration, SC stimulation with IPGs longer than 0.5 ms, or asymmetric stimuli with large duration ratios (≥20) were most effective in threshold reduction. Phosphene shape analysis did not reveal a significant change in percept elongation with SA stimulation. However, there was a significant increase in percept size (P < 0.01) with AA stimulation compared to the standard pulse in one participant. Significane Including asymmetric waveform capability will provide more flexible options for optimization and personalized fitting of retinal implants.
Collapse
Affiliation(s)
- Dorsa Haji Ghaffari
- Department of Biomedical Engineering, Michigan Engineering, University of Michigan, Ann Arbor, MI 48109, United States of America. Biointerfaces Institute, University of Michigan, Ann Arbor, MI 48109, United States of America
| | | | | | | | | | | | | |
Collapse
|
28
|
Tong W, Hejazi M, Garrett DJ, Esler T, Prawer S, Meffin H, Ibbotson MR. Minimizing axon bundle activation of retinal ganglion cells with oriented rectangular electrodes. J Neural Eng 2020; 17:036016. [PMID: 32375131 DOI: 10.1088/1741-2552/ab909e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Retinal prostheses aim to restore vision in patients with retinal degenerative diseases, such as age-related macular degeneration and retinitis pigmentosa. By implanting an array of microelectrodes, such a device creates percepts in patients through electrical stimulation of surviving retinal neurons. A challenge for retinal prostheses when trying to return high quality vision is the unintended activation of retinal ganglion cells through the stimulation of passing axon bundles, which leads to patients reporting large, elongated patches of light instead of focal spots. APPROACH In this work, we used calcium imaging to record the responses of retinal ganglion cells to electrical stimulation in explanted retina using rectangular electrodes placed with different orientations relative to the axon bundles. MAIN RESULTS We showed that narrow, rectangular electrodes oriented parallel to the axon bundles can achieve focal stimulation. To further improve the strategy, we studied the impact of different stimulation waveforms and electrode configurations. We found the selectivity for focal stimulation to be higher when using short (33 μs), anodic-first biphasic pulses, with long electrode lengths and at least 50 μm electrode-to-retinal separation. Focal stimulation was, in fact, less selective when the electrodes made direct contact with the retinal surface due to unwanted preferential stimulation of the proximal axon bundles. SIGNIFICANCE When employed in retinal prostheses, the proposed stimulation strategy is expected to provide improved quality of vision to the blind.
Collapse
Affiliation(s)
- Wei Tong
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia. School of Physics, The University of Melbourne, Parkville, VIC, Australia. Department of Vision Science and Optometry, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Parkville, VIC, Australia
| | | | | | | | | | | | | |
Collapse
|
29
|
Tong W, Stamp M, Hejazi M, Garrett D, Prawer S, Ibbotson MR. The Effects of Phase Durations on the Spatial Responses of Retinal Ganglion Cells to Epi- and Sub-Retinal Electrical Stimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:1795-1800. [PMID: 31946245 DOI: 10.1109/embc.2019.8857347] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Retinal prostheses have the potential to restore vision to blind patients that have retinitis pigmentosa or similar hereditary degenerative disorders, by electrically stimulating surviving retinal neurons through implanted electrode arrays. Current retinal prostheses provide limited visual acuity and one challenge is to spatially control neural activation following electrical stimulation. Most of the retinal prostheses are either epi-retinal - in front of the retinal ganglion cell layer, or sub-retinal - behind photoreceptor layer. In this study, we performed calcium imaging of ganglion cells from whole mounted retinas and compared the spread of neural activation between epi-retinal stimulation with a fiber electrode and sub-retinal stimulation with a disk electrode. We investigated the effects of phase durations on the spatial resolution of biphasic stimulation. Our results suggest that with fiber electrode epi-retinal stimulation, the axon bundles activation can lead to significant spread of stimulation, and cannot be avoided simply by changing the phase durations. However, sub-retinal stimulation with very short pulses (phase duration 0.033ms) can effectively confine the activation of retinal ganglion cells.
Collapse
|
30
|
Tong W, Meffin H, Garrett DJ, Ibbotson MR. Stimulation Strategies for Improving the Resolution of Retinal Prostheses. Front Neurosci 2020; 14:262. [PMID: 32292328 PMCID: PMC7135883 DOI: 10.3389/fnins.2020.00262] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 03/09/2020] [Indexed: 12/17/2022] Open
Abstract
Electrical stimulation using implantable devices with arrays of stimulating electrodes is an emerging therapy for neurological diseases. The performance of these devices depends greatly on their ability to activate populations of neurons with high spatiotemporal resolution. To study electrical stimulation of populations of neurons, retina serves as a useful model because the neural network is arranged in a planar array that is easy to access. Moreover, retinal prostheses are under development to restore vision by replacing the function of damaged light sensitive photoreceptors, which makes retinal research directly relevant for curing blindness. Here we provide a progress review on stimulation strategies developed in recent years to improve the resolution of electrical stimulation in retinal prostheses. We focus on studies performed with explanted retinas, in which electrophysiological techniques are the most advanced. We summarize achievements in improving the spatial and temporal resolution of electrical stimulation of the retina and methods to selectively stimulate neurons with different visual functions. Future directions for retinal prostheses development are also discussed, which could provide insights for other types of neuromodulatory devices in which high-resolution electrical stimulation is required.
Collapse
Affiliation(s)
- Wei Tong
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, Melbourne School of Health Sciences, The University of Melbourne, Melbourne, VIC, Australia
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
| | - Hamish Meffin
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, Melbourne School of Health Sciences, The University of Melbourne, Melbourne, VIC, Australia
- Department of Biomedical Engineering, The University of Melbourne, Melbourne, VIC, Australia
| | - David J. Garrett
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
| | - Michael R. Ibbotson
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, Melbourne School of Health Sciences, The University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
31
|
Höfling L, Oesterle J, Berens P, Zeck G. Probing and predicting ganglion cell responses to smooth electrical stimulation in healthy and blind mouse retina. Sci Rep 2020; 10:5248. [PMID: 32251331 PMCID: PMC7090015 DOI: 10.1038/s41598-020-61899-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 02/19/2020] [Indexed: 11/14/2022] Open
Abstract
Retinal implants are used to replace lost photoreceptors in blind patients suffering from retinopathies such as retinitis pigmentosa. Patients wearing implants regain some rudimentary visual function. However, it is severely limited compared to normal vision because non-physiological stimulation strategies fail to selectively activate different retinal pathways at sufficient spatial and temporal resolution. The development of improved stimulation strategies is rendered difficult by the large space of potential stimuli. Here we systematically explore a subspace of potential stimuli by electrically stimulating healthy and blind mouse retina in epiretinal configuration using smooth Gaussian white noise delivered by a high-density CMOS-based microelectrode array. We identify linear filters of retinal ganglion cells (RGCs) by fitting a linear-nonlinear-Poisson (LNP) model. Our stimulus evokes spatially and temporally confined spiking responses in RGC which are accurately predicted by the LNP model. Furthermore, we find diverse shapes of linear filters in the linear stage of the model, suggesting diverse preferred electrical stimuli of RGCs. The linear filter base identified by our approach could provide a starting point of a model-guided search for improved stimuli for retinal prosthetics.
Collapse
Affiliation(s)
- Larissa Höfling
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany
- Graduate Training Centre of Neuroscience, University of Tübingen, Tübingen, Germany
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
- Centre for Integrative Neuroscience, University of Tübingen, Tübingen, Germany
| | - Jonathan Oesterle
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
| | - Philipp Berens
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
- Bernstein Center for Computational Neuroscience, University of Tübingen, Tübingen, Germany
- Department of Computer Science, University of Tübingen, Tübingen, Germany
| | - Günther Zeck
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany.
- Bernstein Center for Computational Neuroscience, University of Tübingen, Tübingen, Germany.
| |
Collapse
|
32
|
Finn KE, Zander HJ, Graham RD, Lempka SF, Weiland JD. A Patient-Specific Computational Framework for the Argus II Implant. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2020; 1:190-196. [PMID: 33748766 PMCID: PMC7971167 DOI: 10.1109/ojemb.2020.3001563] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Goal Retinal prosthesis performance is limited by the variability of elicited phosphenes. The stimulating electrode's position with respect to retinal ganglion cells (RGCs) affects both perceptual threshold and phosphene shape. We created a modeling framework incorporating patient-specific anatomy and electrode location to investigate RGC activation and predict inter-electrode differences for one Argus II user. Methods We used ocular imaging to build a three-dimensional finite element model characterizing retinal morphology and implant placement. To predict the neural response to stimulation, we coupled electric fields with multi-compartment cable models of RGCs. We evaluated our model predictions by comparing them to patient-reported perceptual threshold measurements. Results Our model was validated by the ability to replicate clinical impedance and threshold values, along with known neurophysiological trends. Inter-electrode threshold differences in silico correlated with in vivo results. Conclusions We developed a patient-specific retinal stimulation framework to quantitatively predict RGC activation and better explain phosphene variations.
Collapse
Affiliation(s)
- Kathleen E Finn
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA and are associated with the Biointerfaces Institute
| | - Hans J Zander
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA and are associated with the Biointerfaces Institute
| | - Robert D Graham
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA and are associated with the Biointerfaces Institute
| | - Scott F Lempka
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA and are associated with the Biointerfaces Institute
| | - James D Weiland
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA and are associated with the Biointerfaces Institute
| |
Collapse
|
33
|
An update on retinal prostheses. Clin Neurophysiol 2019; 131:1383-1398. [PMID: 31866339 DOI: 10.1016/j.clinph.2019.11.029] [Citation(s) in RCA: 89] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 11/13/2019] [Accepted: 11/14/2019] [Indexed: 11/23/2022]
Abstract
Retinal prostheses are designed to restore a basic sense of sight to people with profound vision loss. They require a relatively intact posterior visual pathway (optic nerve, lateral geniculate nucleus and visual cortex). Retinal implants are options for people with severe stages of retinal degenerative disease such as retinitis pigmentosa and age-related macular degeneration. There have now been three regulatory-approved retinal prostheses. Over five hundred patients have been implanted globally over the past 15 years. Devices generally provide an improved ability to localize high-contrast objects, navigate, and perform basic orientation tasks. Adverse events have included conjunctival erosion, retinal detachment, loss of light perception, and the need for revision surgery, but are rare. There are also specific device risks, including overstimulation (which could cause damage to the retina) or delamination of implanted components, but these are very unlikely. Current challenges include how to improve visual acuity, enlarge the field-of-view, and reduce a complex visual scene to its most salient components through image processing. This review encompasses the work of over 40 individual research groups who have built devices, developed stimulation strategies, or investigated the basic physiology underpinning retinal prostheses. Current technologies are summarized, along with future challenges that face the field.
Collapse
|
34
|
Raghuram V, Werginz P, Fried SI. Scaling of the AIS and Somatodendritic Compartments in α S RGCs. Front Cell Neurosci 2019; 13:436. [PMID: 31611777 PMCID: PMC6777007 DOI: 10.3389/fncel.2019.00436] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 09/13/2019] [Indexed: 11/21/2022] Open
Abstract
The anatomical properties of the axon initial segment (AIS) are tailored in certain types of CNS neurons to help optimize different aspects of neuronal function. Here, we questioned whether the AISs of retinal ganglion cells (RGC) were similarly customized, and if so, whether they supported specific RGC functions. To explore this, we measured the AIS properties in alpha sustained RGCs (α S RGCs) of mouse; α S RGCs sizes vary systematically along the nasal temporal axis of the retina, making these cells an attractive population with which to study potential correlations between AIS properties and cell size. Measurements of AIS length as well as distance from the soma revealed that both were scaled to cell size, i.e., cells with large dendritic fields had long AISs that were relatively far from the soma. Within the AIS, the percentage of Na v 1.6 voltage-gated sodium channels remained highly consistent, regardless of cell size or other AIS properties. Although ON RGCs were slightly larger than OFF cells at any given location of the retina, the level of scaling and relative distribution of voltage-gated sodium channels were highly similar. Computational modeling revealed that AIS scaling influenced spiking thresholds, spike rate as well as the kinetics of individual action potentials, Interestingly, the effect of individual features of the AIS varied for different neuronal functions, e.g., AIS length had a larger effect on the efficacy by which the AIS initiated spike triggered the somatic spike than it did on repetitive spiking. The polarity of the effect varied for different properties, i.e., increases to soma size increased spike threshold while increases to AIS length decreased threshold. Thus, variations in the relative level of scaling for individual components could fine tune threshold or other neuronal functions. Light responses were highly consistent across the full range of cell sizes suggesting that scaling may post-synaptically shape response stability, e.g., in addition to several well-known pre-synaptic contributors.
Collapse
Affiliation(s)
- Vineeth Raghuram
- Rehabilitation Research & Development Service, Boston VA Healthcare System, Boston, MA, United States
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
- Department of Biomedical Engineering, Tufts University, Medford, MA, United States
| | - Paul Werginz
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
- Institute for Analysis and Scientific Computing, Vienna University of Technology, Vienna, Austria
| | - Shelley I. Fried
- Rehabilitation Research & Development Service, Boston VA Healthcare System, Boston, MA, United States
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
| |
Collapse
|
35
|
Gaillet V, Cutrone A, Artoni F, Vagni P, Mega Pratiwi A, Romero SA, Lipucci Di Paola D, Micera S, Ghezzi D. Spatially selective activation of the visual cortex via intraneural stimulation of the optic nerve. Nat Biomed Eng 2019; 4:181-194. [DOI: 10.1038/s41551-019-0446-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2018] [Accepted: 07/18/2019] [Indexed: 01/22/2023]
|
36
|
Flores T, Huang T, Bhuckory M, Ho E, Chen Z, Dalal R, Galambos L, Kamins T, Mathieson K, Palanker D. Honeycomb-shaped electro-neural interface enables cellular-scale pixels in subretinal prosthesis. Sci Rep 2019; 9:10657. [PMID: 31337815 PMCID: PMC6650428 DOI: 10.1038/s41598-019-47082-y] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Accepted: 07/10/2019] [Indexed: 11/08/2022] Open
Abstract
High-resolution visual prostheses require small, densely packed pixels, but limited penetration depth of the electric field formed by a planar electrode array constrains such miniaturization. We present a novel honeycomb configuration of an electrode array with vertically separated active and return electrodes designed to leverage migration of retinal cells into voids in the subretinal space. Insulating walls surrounding each pixel decouple the field penetration depth from the pixel width by aligning the electric field vertically, enabling a decrease of the pixel size down to cellular dimensions. We demonstrate that inner retinal cells migrate into the 25 μm deep honeycomb wells as narrow as 18 μm, resulting in more than half of these cells residing within the electrode cavities. Immune response to honeycombs is comparable to that with planar arrays. Modeled stimulation threshold current density with honeycombs does not increase substantially with reduced pixel size, unlike quadratic increase with planar arrays. This 3-D electrode configuration may enable functional restoration of central vision with acuity better than 20/100 for millions of patients suffering from age-related macular degeneration.
Collapse
Affiliation(s)
- Thomas Flores
- Department of Applied Physics, Stanford University, Stanford, CA, USA.
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA.
| | - Tiffany Huang
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Mohajeet Bhuckory
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
- Department of Ophthalmology, Stanford University, Stanford, CA, USA
| | - Elton Ho
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
- Department of Physics, Stanford University, Stanford, CA, USA
| | - Zhijie Chen
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Roopa Dalal
- Department of Ophthalmology, Stanford University, Stanford, CA, USA
| | - Ludwig Galambos
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Theodore Kamins
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Keith Mathieson
- Institute of Photonics, University of Strathclyde, Glasgow, Scotland, UK
| | - Daniel Palanker
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
- Department of Ophthalmology, Stanford University, Stanford, CA, USA
| |
Collapse
|
37
|
A model of ganglion axon pathways accounts for percepts elicited by retinal implants. Sci Rep 2019; 9:9199. [PMID: 31235711 PMCID: PMC6591412 DOI: 10.1038/s41598-019-45416-4] [Citation(s) in RCA: 79] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Accepted: 06/04/2019] [Indexed: 11/09/2022] Open
Abstract
Degenerative retinal diseases such as retinitis pigmentosa and macular degeneration cause irreversible vision loss in more than 10 million people worldwide. Retinal prostheses, now implanted in over 250 patients worldwide, electrically stimulate surviving cells in order to evoke neuronal responses that are interpreted by the brain as visual percepts ('phosphenes'). However, instead of seeing focal spots of light, current implant users perceive highly distorted phosphenes that vary in shape both across subjects and electrodes. We characterized these distortions by asking users of the Argus retinal prosthesis system (Second Sight Medical Products Inc.) to draw electrically elicited percepts on a touchscreen. Using ophthalmic fundus imaging and computational modeling, we show that elicited percepts can be accurately predicted by the topographic organization of optic nerve fiber bundles in each subject's retina, successfully replicating visual percepts ranging from 'blobs' to oriented 'streaks' and 'wedges' depending on the retinal location of the stimulating electrode. This provides the first evidence that activation of passing axon fibers accounts for the rich repertoire of phosphene shape commonly reported in psychophysical experiments, which can severely distort the quality of the generated visual experience. Overall our findings argue for more detailed modeling of biological detail across neural engineering applications.
Collapse
|
38
|
Manfredi G, Colombo E, Barsotti J, Benfenati F, Lanzani G. Photochemistry of Organic Retinal Prostheses. Annu Rev Phys Chem 2019; 70:99-121. [DOI: 10.1146/annurev-physchem-042018-052445] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Organic devices are attracting considerable attention as prostheses for the recovery of retinal light sensitivity lost to retinal degenerative disease. The biotic/abiotic interface created when light-sensitive polymers and living tissues are placed in contact allows excitation of a response in blind laboratory rats exposed to visual stimuli. Although polymer retinal prostheses have proved to be efficient, their working mechanism is far from being fully understood. In this review article, we discuss the results of the studies conducted on these kinds of polymer devices and compare them with the data found in the literature for inorganic retinal prostheses, where the working mechanisms are better comprehended. This comparison, which tries to set some reference values and figures of merit, is intended for use as a starting point to determine the direction for further investigation.
Collapse
Affiliation(s)
- Giovanni Manfredi
- Center for Nano Science and Technology, Istituto Italiano di Tecnologia, 20133 Milan, Italy;,
| | - Elisabetta Colombo
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, 16132 Genoa, Italy;,
| | - Jonathan Barsotti
- Center for Nano Science and Technology, Istituto Italiano di Tecnologia, 20133 Milan, Italy;,
| | - Fabio Benfenati
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, 16132 Genoa, Italy;,
- Department of Experimental Medicine, University of Genoa, 16132 Genoa, Italy
| | - Guglielmo Lanzani
- Center for Nano Science and Technology, Istituto Italiano di Tecnologia, 20133 Milan, Italy;,
- Department of Physics, Politecnico di Milano, 20133 Milan, Italy
| |
Collapse
|
39
|
Rincón Montes V, Gehlen J, Lück S, Mokwa W, Müller F, Walter P, Offenhäusser A. Toward a Bidirectional Communication Between Retinal Cells and a Prosthetic Device - A Proof of Concept. Front Neurosci 2019; 13:367. [PMID: 31114470 PMCID: PMC6502975 DOI: 10.3389/fnins.2019.00367] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Accepted: 04/01/2019] [Indexed: 01/15/2023] Open
Abstract
Background: Significant progress toward the recovery of useful vision in blind patients with severe degenerative retinal diseases caused by photoreceptor death has been achieved with the development of visual prostheses that stimulate the retina electrically. However, currently used prostheses do not provide feedback about the retinal activity before and upon stimulation and do not adjust to changes during the remodeling processes in the retina. Both features are desirable to improve the efficiency of the electrical stimulation (ES) therapy offered by these devices. Accordingly, devices that not only enable ES but at the same time provide information about the retinal activity are beneficial. Given the above, a bidirectional communication strategy, in which inner retinal cells are stimulated and the output neurons of the retina, the ganglion cells, are recorded using penetrating microelectrode arrays (MEAs) is proposed. Methods: Custom-made penetrating MEAs with four silicon-based shanks, each one with three or four iridium oxide electrodes specifically designed to match retinal dimensions were used to record the activity of light-adapted wildtype mice retinas and degenerated retinas from rd10 mice in vitro. In addition, responses to high potassium concentration and to light stimulation in wildtype retinas were examined. Furthermore, voltage-controlled ES was performed. Results: The spiking activity of retinal ganglion cells (RGCs) was recorded at different depths of penetration inside the retina. Physiological responses during an increase of the extracellular potassium concentration and phasic and tonic responses during light stimulation were captured. Moreover, pathologic rhythmic activity was recorded from degenerated retinas. Finally, ES of the inner retina and simultaneous recording of the activity of RGCs was accomplished. Conclusion: The access to different layers of the retina with penetrating electrodes while recording at the same time the spiking activity of RGCs broadens the use and the field of action of multi-shank and multi-site penetrating MEAs for retinal applications. It enables a bidirectional strategy to stimulate inner retinal cells electrically and to record from the spiking RGCs simultaneously (BiMEA). This opens the possibility of a feedback loop system to acknowledge the success of ES carried out by retinal prostheses.
Collapse
Affiliation(s)
- Viviana Rincón Montes
- Bioelectronics, Institute of Complex Systems-8, Forschungszentrum Jülich, Jülich, Germany
| | - Jana Gehlen
- Cellular Biophysics, Institute of Complex Systems-4, Forschungszentrum Jülich, Jülich, Germany
| | - Stefan Lück
- Department of Materials in Electrical Engineering 1, RWTH Aachen University, Aachen, Germany
| | - Wilfried Mokwa
- Department of Materials in Electrical Engineering 1, RWTH Aachen University, Aachen, Germany
| | - Frank Müller
- Cellular Biophysics, Institute of Complex Systems-4, Forschungszentrum Jülich, Jülich, Germany
| | - Peter Walter
- Department of Ophthalmology, RWTH Aachen University, Aachen, Germany
| | - Andreas Offenhäusser
- Bioelectronics, Institute of Complex Systems-8, Forschungszentrum Jülich, Jülich, Germany
| |
Collapse
|
40
|
Beyeler M. Commentary: Detailed Visual Cortical Responses Generated by Retinal Sheet Transplants in Rats With Severe Retinal Degeneration. Front Neurosci 2019; 13:471. [PMID: 31133795 PMCID: PMC6524404 DOI: 10.3389/fnins.2019.00471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Accepted: 04/26/2019] [Indexed: 11/14/2022] Open
Affiliation(s)
- Michael Beyeler
- Vision and Cognition Laboratory, Department of Psychology, University of Washington, Seattle, WA, United States
- Institute for Neuroengineering, University of Washington, Seattle, WA, United States
- eScience Institute, University of Washington, Seattle, WA, United States
| |
Collapse
|
41
|
Rountree CM, Troy JB, Saggere L. Investigation of Injection Depth for Subretinal Delivery of Exogenous Glutamate to Restore Vision via Biomimetic Chemical Neuromodulation. IEEE Trans Biomed Eng 2019; 67:464-470. [PMID: 31071013 DOI: 10.1109/tbme.2019.2915255] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Chemical neuromodulation of the retina using native neurotransmitters to biomimetically activate target retinal neurons through chemical synapses is a promising biomimetic alternative to electrical stimulation for restoring vision in blindness caused by photoreceptor degenerative diseases. Recent research has shown that subretinal chemical stimulation could be advantageous for treating photoreceptor degenerative diseases but many of the parameters for achieving efficacious chemical neuromodulation are yet to be explored. In this paper, we investigated how the depth at which neurotransmitter is injected subretinally affects the success rate, spike rate characteristics (i.e., amplitude, response latency, and time width), and spatial resolution of chemical stimulation in wild-type Long Evans and photoreceptor degenerated S334ter-3 transgenic rat retinas in vitro. We compared the responses to injections of glutamate at the subretinal surface and two subsurface depths near the outer and inner plexiform layers and found that while injections at all depths elicited robust retinal ganglion cell responses, they differed significantly in terms of the spike rate characteristics and spatial resolutions across injection depths. Shallow subsurface injections near the outer plexiform layer evoked the highest spike rate amplitudes and had the highest spatial resolution and success rates, while deep subsurface injections near the inner plexiform layer elicited the shortest latencies and narrowest time widths. Our results suggest that surface injections are suboptimal for subretinal chemical neuromodulation, while shallow subsurface and deep subsurface injections may optimize high spatial and high temporal resolution, respectively. These findings have great significance for the design and development of a potential neurotransmitter-based subretinal prosthesis.
Collapse
|
42
|
Ueno S, Kominami T, Okado S, Inooka D, Kondo M, Terasaki H. Course of loss of photoreceptor function and progressive Müller cell gliosis in rhodopsin P347L transgenic rabbits. Exp Eye Res 2019; 184:192-200. [PMID: 31029790 DOI: 10.1016/j.exer.2019.04.026] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 04/17/2019] [Accepted: 04/24/2019] [Indexed: 01/31/2023]
Abstract
Long living animal models of retinitis pigmentosa (RP) can provide important information on the retinal changes that occur at the late stages of photoreceptor degeneration. The rhodopsin Pro347Leu transgenic rabbit (P347L Tg) is a model of RP, and it has been used to analyze the functional and morphological changes in the retina following the degeneration of the photoreceptors. They have also been used to test newly-developed therapies to treat eyes with photoreceptor degeneration. However, assessments of the retinal changes in P347L Tg rabbits older than 1-year have not been reported even though the data are important for research on developing new therapies to restore vision at the end stages of RP. The purpose of this study was to determine the time course of the loss of photoreceptor function and the changes in the morphology of the retina of P347L Tg rabbits. The experiments were performed on 26 older P347L Tg rabbits. The results showed that the amplitudes of the ERGs of the P347L Tg rabbits gradually decreased and reached <10 μV between 30- and 54-months-of-age. Histological analysis at these later stages showed a loss of the photoreceptor layer, and OCT analysis showed absence of the layering of the retina. However, the thickness between the inner limiting membrane and the outer plexiform layer was about 1.7 times thicker than the corresponding thickness of WT rabbits in the OCT images. This thickening was caused by a marked gliosis of the entire retina which was confirmed by light and transmission electron microscopy. In addition, immunohistochemical analysis showed there was excessive staining of the glial fibrillary acid protein in the older P347L Tg rabbits although the rod ON bipolar cells and horizontal cells were still present in the inner nuclear layer. Our results indicate that the P347L Tg rabbit progressed to complete photoreceptor loss within 30- and 54-months-of-age and severe gliosis altered the morphology of the retina.
Collapse
Affiliation(s)
- Shinji Ueno
- Department of Ophthalmology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
| | - Taro Kominami
- Department of Ophthalmology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Satoshi Okado
- Department of Ophthalmology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Daiki Inooka
- Department of Ophthalmology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Mineo Kondo
- Department of Ophthalmology, Mie University Graduate School of Medicine, Tsu, Japan
| | - Hiroko Terasaki
- Department of Ophthalmology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| |
Collapse
|
43
|
Nimmagadda K, Weiland JD. Retinotopic Responses in the Visual Cortex Elicited by Epiretinal Electrical Stimulation in Normal and Retinal Degenerate Rats. Transl Vis Sci Technol 2018; 7:33. [PMID: 30402340 PMCID: PMC6213779 DOI: 10.1167/tvst.7.5.33] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 08/24/2018] [Indexed: 01/31/2023] Open
Abstract
Purpose Electronic retinal prostheses restore vision in people with outer retinal degeneration by electrically stimulating the inner retina. We characterized visual cortex electrophysiologic response elicited by electrical stimulation of retina in normally sighted and retinal degenerate rats. Methods Nine normally sighted Long Evans and 11 S334ter line 3 retinal degenerate (rd) rats were used to map cortical responses elicited by epiretinal electrical stimulation in four quadrants of the retina. Six normal and six rd rats were used to compare the dendritic spine density of neurons in the visual cortex. Results The rd rats required higher stimulus amplitudes to elicit responses in the visual cortex. The cortical electrically evoked responses (EERs) for both healthy and rd rats show a dose-response characteristic with respect to the stimulus amplitude. The EER maps in healthy rats show retinotopic organization. For rd rats, cortical retinotopy is not well preserved. The neurons in the visual cortex of rd rats show a 10% higher dendritic spine density than in the healthy rats. Conclusions Cortical activity maps, produced when epiretinal stimulation is applied to quadrants of the retina, exhibit retinotopy in normal but not rd rats. This is likely due to a combination of degeneration of the retina and increased stimulus thresholds in rd, which broadens the activated area of the retina. Translational Relevance Loss of retinotopy is evident in rd rats. If a similar loss of retinotopy is present in humans, retinal prostheses design must include flexibility to account for patient specific variability.
Collapse
Affiliation(s)
- Kiran Nimmagadda
- Neuroscience Graduate Program, University of Southern California, Los Angeles, CA, USA.,USC - Caltech MD/PhD Program, Los Angeles, CA, USA
| | - James D Weiland
- Department of Biomedical Engineering, The University of Michigan, Ann Arbor, MI, USA.,Department of Ophthalmology and Visual Sciences, The University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
44
|
Rathbun DL, Ghorbani N, Shabani H, Zrenner E, Hosseinzadeh Z. Spike-triggered average electrical stimuli as input filters for bionic vision—a perspective. J Neural Eng 2018; 15:063002. [DOI: 10.1088/1741-2552/aae493] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
45
|
Stasheff SF. Clinical Impact of Spontaneous Hyperactivity in Degenerating Retinas: Significance for Diagnosis, Symptoms, and Treatment. Front Cell Neurosci 2018; 12:298. [PMID: 30250425 PMCID: PMC6139326 DOI: 10.3389/fncel.2018.00298] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Accepted: 08/17/2018] [Indexed: 11/23/2022] Open
Abstract
Hereditary retinal degenerations result from varied pathophysiologic mechanisms, all ultimately characterized by photoreceptor dysfunction and death. Hence, much research on these diseases has concentrated on the outer retina. Over the past decade or so increasing attention has focused on concomitant changes in complex inner retinal neural circuits that process visual signals for transmission to the brain. One striking abnormality develops before the ultimately profound anatomic disruption of the inner retina. Highly elevated spontaneous activity was first demonstrated in central nervous system visual centers in vivo by Dräger and Hubel (1978), and subsequently has been confirmed in vitro, now in multiple animal models and by multiple investigators (see other contributions to this Research Topic). What evidence exists that this phenomenon occurs in human patients with retinal degeneration, and what is the ultimate effect of spontaneous hyperactivity in the output neurons, the retinal ganglion cells? Here I summarize abnormalities of visual perception among patients with retinal degeneration that may arise from hyperactivity. Next, I consider the disruption of neural encoding and anatomic connectivity that may result within the retina and in downstream visual centers of the brain. I then consider how specific characteristics of hyperactivity may distinguish various forms or stages of retinal degeneration, potentially helping in the near future to refine diagnosis and/or treatment choices for different patients. Finally, I review how consideration of these features may help optimize pharmacologic, gene, stem cell, prosthetic or other therapies to forestall visual loss or restore sight.
Collapse
Affiliation(s)
- Steven F Stasheff
- Center for Neuroscience and Behavioral Medicine, Gilbert Family Neurofibromatosis Institute, Children's National Health System, Washington, DC, United States.,Visual Neurophysiology, Neuro-ophthalmology and Pediatric Neurology, Retinal Neurophysiology Section, National Eye Institute, Bethesda, MD, United States
| |
Collapse
|
46
|
Yang JW, Tseng ML, Fu YM, Kang CH, Cheng YT, Kuo PH, Tzeng CK, Chiou SH, Wu CY, Chen GY. Printable Graphene Oxide Micropatterns for a Bio-Subretinal Chip. Adv Healthc Mater 2018; 7:e1800365. [PMID: 30051620 DOI: 10.1002/adhm.201800365] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2018] [Revised: 06/09/2018] [Indexed: 01/23/2023]
Abstract
Recently, implantable artificial subretinal chips using electronic components have replaced photoreceptors to serve as the most feasible treatment for retinal diseases. As such a chip that is meant to be implanted and used for very long periods, growing retinal cells on it to improve the electrical stimulation efficiency and attraction of neuronal elements remains a challenge. Here, an inkjet printing technology is employed to create graphene oxide (GO) micropatterns onto microelectrodes of a photovoltaic-powered implantable retinal chip. These GO micropatterns allow human retinal pigment epithelium (RPE) cells to specially attach and grow in each microelectrode. In addition, the cell proliferation, viability, and tight junction of RPE cells are improved during culturing. The development of a simple surface-coating technology would pave the way for the development of the first fully integrated and encapsulated retinal prostheses with biocompatible on-chip microelectrodes for long-term implantation, which could be effectively applied in retina tissue engineering and therapy.
Collapse
Affiliation(s)
- Jia-Wei Yang
- Department of Electrical and Computer Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
- Institute of Biomedical Engineering; College of Electrical and Computer Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
| | - Ming-Liang Tseng
- Institute of Biomedical Engineering; College of Electrical and Computer Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
| | - Yu-Min Fu
- Microsystems Integration Laboratory; Department of Electronics Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
| | - Che-Hao Kang
- Microsystems Integration Laboratory; Department of Electronics Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
| | - Yu-Ting Cheng
- Microsystems Integration Laboratory; Department of Electronics Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
| | - Po-Han Kuo
- Department of Electrical Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
| | - Chi-Kuan Tzeng
- Department of Electrical Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
| | - Shih-Hwa Chiou
- Institute of Pharmacology; School of Medicine; National Yang-Ming University; Taipei 112 Taiwan
- Department of Medical Research; Taipei Veterans General Hospital; Taipei 112 Taiwan
- Genomics Research Center; Academia Sinica; Taipei 115 Taiwan
| | - Chung-Yu Wu
- Department of Electrical Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
| | - Guan-Yu Chen
- Institute of Biomedical Engineering; College of Electrical and Computer Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
- Department of Biological Science and Technology; National Chiao Tung University; Hsinchu 300 Taiwan
- Institute of Biomedical Engineering; College of Electrical and Computer Engineering; National Chiao Tung University; Hsinchu 300 Taiwan
| |
Collapse
|
47
|
Fernandez E. Development of visual Neuroprostheses: trends and challenges. Bioelectron Med 2018; 4:12. [PMID: 32232088 PMCID: PMC7098238 DOI: 10.1186/s42234-018-0013-8] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2018] [Accepted: 07/27/2018] [Indexed: 02/06/2023] Open
Abstract
Visual prostheses are implantable medical devices that are able to provide some degree of vision to individuals who are blind. This research field is a challenging subject in both ophthalmology and basic science that has progressed to a point where there are already several commercially available devices. However, at present, these devices are only able to restore a very limited vision, with relatively low spatial resolution. Furthermore, there are still many other open scientific and technical challenges that need to be solved to achieve the therapeutic benefits envisioned by these new technologies. This paper provides a brief overview of significant developments in this field and introduces some of the technical and biological challenges that still need to be overcome to optimize their therapeutic success, including long-term viability and biocompatibility of stimulating electrodes, the selection of appropriate patients for each artificial vision approach, a better understanding of brain plasticity and the development of rehabilitative strategies specifically tailored for each patient.
Collapse
Affiliation(s)
- Eduardo Fernandez
- Institute of Bioengineering, University Miguel Hernández and CIBER-BBN, Avda de la Universidad, s/n, 03202 Alicante, Elche Spain.,2John A. Moran Eye Center, University of Utah, Salt Lake City, USA
| |
Collapse
|
48
|
Eshraghian JK, Baek S, Kim JH, Iannella N, Cho K, Goo YS, Iu HHC, Kang SM, Eshraghian K. Formulation and Implementation of Nonlinear Integral Equations to Model Neural Dynamics Within the Vertebrate Retina. Int J Neural Syst 2018; 28:1850004. [PMID: 29631506 DOI: 10.1142/s0129065718500041] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Existing computational models of the retina often compromise between the biophysical accuracy and a hardware-adaptable methodology of implementation. When compared to the current modes of vision restoration, algorithmic models often contain a greater correlation between stimuli and the affected neural network, but lack physical hardware practicality. Thus, if the present processing methods are adapted to complement very-large-scale circuit design techniques, it is anticipated that it will engender a more feasible approach to the physical construction of the artificial retina. The computational model presented in this research serves to provide a fast and accurate predictive model of the retina, a deeper understanding of neural responses to visual stimulation, and an architecture that can realistically be transformed into a hardware device. Traditionally, implicit (or semi-implicit) ordinary differential equations (OES) have been used for optimal speed and accuracy. We present a novel approach that requires the effective integration of different dynamical time scales within a unified framework of neural responses, where the rod, cone, amacrine, bipolar, and ganglion cells correspond to the implemented pathways. Furthermore, we show that adopting numerical integration can both accelerate retinal pathway simulations by more than 50% when compared with traditional ODE solvers in some cases, and prove to be a more realizable solution for the hardware implementation of predictive retinal models.
Collapse
Affiliation(s)
- Jason K Eshraghian
- 1 School of Electrical, Electronic and Computer Engineering, University of Western Australia, Crawley, Australia
| | - Seungbum Baek
- 2 College of Electrical and Computer Engineering, Chungbuk National University, Cheongju, Republic of Korea
| | - Jun-Ho Kim
- 2 College of Electrical and Computer Engineering, Chungbuk National University, Cheongju, Republic of Korea
| | | | - Kyoungrok Cho
- 2 College of Electrical and Computer Engineering, Chungbuk National University, Cheongju, Republic of Korea
| | - Yong Sook Goo
- 4 Department of Physiology, School of Medicine, Chungbuk National University, Cheongju, Republic of Korea
| | - Herbert H C Iu
- 1 School of Electrical, Electronic and Computer Engineering, University of Western Australia, Crawley, Australia
| | - Sung-Mo Kang
- 5 Department of Electrical Engineering, University of California, Santa Cruz, Santa Cruz, USA
| | | |
Collapse
|
49
|
Alexander RG, Macknik SL, Martinez-Conde S. Microsaccade Characteristics in Neurological and Ophthalmic Disease. Front Neurol 2018; 9:144. [PMID: 29593642 PMCID: PMC5859063 DOI: 10.3389/fneur.2018.00144] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2017] [Accepted: 02/27/2018] [Indexed: 12/01/2022] Open
Abstract
Microsaccade research has recently reached a critical mass of studies that allows, for the first time, a comprehensive review of how microsaccadic dynamics change in neurological and ophthalmic disease. We discuss the various pathological conditions that affect microsaccades, their impact on microsaccadic and other fixational eye movement dynamics, and the incipient studies that point to microsaccadic features as potential indicators of differential and early diagnoses of multiple clinical conditions, from movement disorders to attention-deficit hyperactivity disorder to amblyopia. We propose that the objective assessment of fixational eye movement parameters may help refine differential diagnostics in neurological disease and assist in the evaluation of ongoing therapy regimes. In addition, determining the effects of ophthalmic disease on fixational eye movement features may help evaluate visual impairment in an objective manner, particularly in young patients or those experiencing communication difficulties.
Collapse
Affiliation(s)
- Robert G Alexander
- State University of New York (SUNY) Downstate Medical Center, Brooklyn, NY, United States
| | - Stephen L Macknik
- State University of New York (SUNY) Downstate Medical Center, Brooklyn, NY, United States
| | - Susana Martinez-Conde
- State University of New York (SUNY) Downstate Medical Center, Brooklyn, NY, United States
| |
Collapse
|
50
|
Walston ST, Chow RH, Weiland JD. Direct measurement of bipolar cell responses to electrical stimulation in wholemount mouse retina. J Neural Eng 2018. [PMID: 29513646 DOI: 10.1088/1741-2552/aab4ed] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVE This in vitro investigation examines the response of retinal bipolar cells to extracellular electrical stimulation. APPROACH In vitro investigations characterizing the response of retinal neurons to electrical stimulation have primarily focused on retinal ganglion cells because they are the output neurons of the retina and their superficial position in the retina makes them readily accessible to in vitro recording techniques. Thus, the majority of information regarding the response of inner retinal neurons has been inferred from ganglion cell activity. Here we use patch clamp electrophysiology to directly record electrically-evoked activity in bipolar cells within the inner retina of normal Tg(Gng13-EGFP)GI206Gsat and degenerate rd10 Tg(Gng13-EGFP)GI206Gsat mice using a wholemount preparation. MAIN RESULTS Bipolar cells respond to electrical stimulation with time-locked depolarizing voltage transients. The latency of the response declines with increases in stimulation amplitude. A desensitizing response is observed during repeated stimulation with 25 ms biphasic current pulses delivered at pulse rates greater than 6 pps. A burst of long-latency (200-1000 ms) inhibitory postsynaptic potentials are evoked by the stimulus and the burst exhibits evidence of a lower and upper stimulation threshold. SIGNIFICANCE These results provide insights into the various types of bipolar cell activity elicited by electrical stimulation and may be useful for future retinal prosthesis stimulation protocols. This investigation uses patch clamp electrophysiology to provide direct analysis of ON-type bipolar cell responses to electrical stimulation in a wholemount retina preparation. It explores the effects of variable stimulus amplitudes, pulse widths, and frequencies in both normal and degenerate retina. The analysis adds to a body of work largely based upon indirect measurements of bipolar cell activity, and the methodology demonstrates an alternative retina preparation technique in which to acquire single-cell activity.
Collapse
Affiliation(s)
- Steven T Walston
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90007, United States of America
| | | | | |
Collapse
|